1
|
Bocian S, Comeaux S, Friis CM, Lardizabal J, Prischak S, Sawyer C, Dedman V, Granato A, Loyola M, Pooler A. Standards of Infection Prevention in the Gastroenterology Setting. Gastroenterol Nurs 2024; 47:383-397. [PMID: 39356127 DOI: 10.1097/sga.0000000000000842] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/03/2024] Open
|
2
|
Li XH, Huang ZY, Zhang YY, Cheng LJ, Zhen J, Zhang Y, Tian X, Huang X, Ma JH. Bacterial bioburden of duodenoscope elevator mechanism in different reprocessing stages. Am J Infect Control 2024; 52:488-490. [PMID: 37838249 DOI: 10.1016/j.ajic.2023.10.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 10/05/2023] [Accepted: 10/06/2023] [Indexed: 10/16/2023]
Abstract
Over the past decade, infections linked to duodenoscopes have become a significant concern, primarily due to the intricate design of the elevator mechanism. Currently, there is limited evidence regarding the bacterial contamination level of the elevator mechanism after clinical use and throughout its various reprocessing stages. This study utilized the swab culture technique to examine the bacterial contamination on the duodenoscope elevator mechanism after clinical use and after 3 reprocessing stages at a Center of tertiary hospital. Our findings revealed severe bacterial contamination after clinical usage, emphasizing that the effectiveness of manual cleaning greatly influences the subsequent high-level disinfection quality.
Collapse
Affiliation(s)
- Xian-Huang Li
- Endoscopy Center, Department of Gastroenterology, the First Affiliated Hospital of Nanchang University, Jiangxi, China
| | - Zi-Yi Huang
- Endoscopy Center, Department of Gastroenterology, the First Affiliated Hospital of Nanchang University, Jiangxi, China; School of Nursing, Nanchang University, Jiangxi, China
| | - Yang-Yang Zhang
- Endoscopy Center, Department of Gastroenterology, the First Affiliated Hospital of Nanchang University, Jiangxi, China; School of Nursing, Nanchang University, Jiangxi, China
| | - Liu-Ji Cheng
- Endoscopy Center, Department of Gastroenterology, the First Affiliated Hospital of Nanchang University, Jiangxi, China; School of Nursing, Nanchang University, Jiangxi, China
| | - Jing Zhen
- Endoscopy Center, Department of Gastroenterology, the First Affiliated Hospital of Nanchang University, Jiangxi, China; School of Nursing, Nanchang University, Jiangxi, China
| | - Yun Zhang
- Endoscopy Center, Department of Gastroenterology, the First Affiliated Hospital of Nanchang University, Jiangxi, China
| | - Xin Tian
- JiangXi College Of Traditional Chinese Medicine, Jiangxi, China
| | - Xi Huang
- Endoscopy Center, Department of Gastroenterology, the First Affiliated Hospital of Nanchang University, Jiangxi, China.
| | - Jiu-Hong Ma
- Endoscopy Center, Department of Gastroenterology, the First Affiliated Hospital of Nanchang University, Jiangxi, China.
| |
Collapse
|
3
|
Ailincai D, Turin Moleavin IA, Sarghi A, Fifere A, Dumbrava O, Pinteala M, Balan GG, Rosca I. New Hydrogels Nanocomposites Based on Chitosan, 2-Formylphenylboronic Acid, and ZnO Nanoparticles as Promising Disinfectants for Duodenoscopes Reprocessing. Polymers (Basel) 2023; 15:2669. [PMID: 37376315 DOI: 10.3390/polym15122669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Revised: 06/09/2023] [Accepted: 06/12/2023] [Indexed: 06/29/2023] Open
Abstract
New hydrogels nanocomposites, based on iminoboronate hydrogels and ZnO nanoparticles (ZnO-NPs), were obtained and characterised in order to develop a new class of disinfectants able to fight the nosocomial infections produced by duodenoscopes investigation procedures. The formation of the imine linkages between chitosan and the aldehyde was demonstrated using NMR and FTIR spectroscopy, while the supramolecular architecture of the developed systems was evaluated via wide-angle X-ray diffraction and polarised optical microscopy. The morphological characterisation of the systems via scanning electron microscopy revealed the highly porous structure of the materials, in which no ZnO agglomeration could be observed, indicating the very fine and homogenous encapsulation of the nanoparticles into the hydrogels. The newly synthetised hydrogels nanocomposites was proven to have synergistic antimicrobial properties, being very efficient as disinfectants against reference strains as: Enterococcus faecalis, Klebsiella pneumoniae, and Candida albicans.
Collapse
Affiliation(s)
- Daniela Ailincai
- "Petru Poni" Institute of Macromolecular Chemistry, 700487 Iasi, Romania
| | | | - Alexandra Sarghi
- "Petru Poni" Institute of Macromolecular Chemistry, 700487 Iasi, Romania
| | - Adrian Fifere
- "Petru Poni" Institute of Macromolecular Chemistry, 700487 Iasi, Romania
| | - Oana Dumbrava
- "Petru Poni" Institute of Macromolecular Chemistry, 700487 Iasi, Romania
| | - Mariana Pinteala
- "Petru Poni" Institute of Macromolecular Chemistry, 700487 Iasi, Romania
| | - Gheorghe G Balan
- Faculty of Medicine, 'Grigore T. Popa' University of Medicine, 700115 Iasi, Romania
- Institute of Gastroenterology and Hepatology, St. Spiridon Emergency County Hospital, 700111 Iasi, Romania
| | - Irina Rosca
- "Petru Poni" Institute of Macromolecular Chemistry, 700487 Iasi, Romania
| |
Collapse
|
4
|
Kwakman JA, Poley MJ, Vos MC, Bruno MJ. Single-use duodenoscopes compared with reusable duodenoscopes in patients carrying multidrug-resistant microorganisms: a break-even cost analysis. Endosc Int Open 2023; 11:E571-E580. [PMID: 37304249 PMCID: PMC10256319 DOI: 10.1055/a-2064-9721] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Accepted: 03/21/2023] [Indexed: 06/13/2023] Open
Abstract
Background and study aims Single-use duodenoscopes can prevent transmission of microorganisms through contaminated reusable duodenoscopes. Concerns regarding their economic and environmental impact impede the transition to single-use duodenoscopes. This study investigated the costs associated with two scenarios in which single-use duodenoscopes are used in patients carrying multidrug-resistant microorganisms (MDROs). Methods Break-even costs for single-use duodenoscopes were calculated for two scenarios in which patients were screened for MDRO carriage before undergoing endoscopic retrograde cholangiopancreatography (ERCP). Only direct costs related to the endoscopy were taken into consideration. In Scenario 1, patients were screened through microbiological culturing with a lag time in receiving the test result. In Scenario 2, screening was performed using GeneXpert analysis providing a rapid read-out. Calculations were performed using data from a Dutch tertiary care center and also with US healthcare data. Results In the Dutch situation, single-use duodenoscopes needed to be priced at a maximum of € 140 to € 250 to break-even. In the US analyses, break-even costs varied widely, depending on the duodenoscope-associated infection costs used, ERCP volume, and infection risk. The break-even costs in Scenario 1 ranged between $78.21 and $2,747.54 and in Scenario 2, between $248.89 and $2,209.23. Conclusions This study showed that a crossover scenario in which single-use duodenoscopes are only used in patients carrying MDROs could be an economically viable alternative to a complete transition to single-use duodenoscopes. In the Dutch setting, single-use duodenoscopes need to be priced much lower than in the United States to reach a per-procedure cost that is comparable with a scenario using reusable duodenoscopes exclusively.
Collapse
Affiliation(s)
- Judith A. Kwakman
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Centre, Rotterdam, The Netherlands
- Department of Medical Microbiology and Infectious Diseases, Erasmus MC University Medical Centre, Rotterdam, The Netherlands
| | - Marten J. Poley
- Institute for Medical Technology Assessment (iMTA) & Erasmus School of Health Policy & Management (ESHPM), Erasmus University Rotterdam, The Netherlands
- Department of Pediatric Surgery and Intensive Care, Sophia Children’s Hospital, Erasmus MC University Medical Centre, Rotterdam, The Netherlands
| | - Margreet C. Vos
- Department of Medical Microbiology and Infectious Diseases, Erasmus MC University Medical Centre, Rotterdam, The Netherlands
| | - Marco J. Bruno
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Centre, Rotterdam, The Netherlands
| |
Collapse
|
5
|
Meeusen V, McLean T. A Single-Blind Study Testing the Preparation Accuracy of Bedside Precleaning Solutions Used for Flexible Endoscopes. Gastroenterol Nurs 2023; 46:144-150. [PMID: 36779976 DOI: 10.1097/sga.0000000000000721] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Accepted: 08/29/2022] [Indexed: 02/14/2023] Open
Abstract
Endoscopy-related pathogen transmission may occur if microorganisms are spread from patient to patient by contaminated equipment. Effective and safe endoscope reprocessing includes bedside precleaning, mechanical cleaning, high-level disinfection, storage, and drying. The aim of this research study was to observe and report on the variation in practice regarding the use of detergent for bedside precleaning of flexible gastrointestinal endoscopes. Endoscopy nurses working in the endoscopy unit at the Princess Alexandra Hospital, Australia, prepared four samples of detergent solution as per normal routine. Twenty-nine nurses participated providing in total 116 samples. There was a significant variation in detergent concentration. The detergent concentration variated between 2.00 and 288.20 ml/L ( M = 34.55, SD = 39.21). Two samples revealed lower concentrations than required. More than 25% of the samples contained at least a 10 times higher concentration than required (>40 ml/L). Current practice of bedside precleaning of gastrointestinal endoscopes was not deemed safe or cost-effective as it did not guarantee an adequate concentration of detergent. More precise methods to establish the required concentration of the bedside precleaning solution were introduced to improve practice.
Collapse
Affiliation(s)
- Vera Meeusen
- Vera Meeusen, PhD, MA, RN, FACPAN, AFACHSM, is A/Professor; Clinical Nurse Consultant, Endoscopy Unit, Princess Alexandra Hospital, Woolloongabba, Queensland, Australia; and A/Professor in Medicine, The University of Queensland, St Lucia, Queensland, Australia
- Traci McLean, Advanced Skilled Endorsed Nurse, Endoscopy Unit, Princess Alexandra Hospital, Woolloongabba, Queensland, Australia
| | - Traci McLean
- Vera Meeusen, PhD, MA, RN, FACPAN, AFACHSM, is A/Professor; Clinical Nurse Consultant, Endoscopy Unit, Princess Alexandra Hospital, Woolloongabba, Queensland, Australia; and A/Professor in Medicine, The University of Queensland, St Lucia, Queensland, Australia
- Traci McLean, Advanced Skilled Endorsed Nurse, Endoscopy Unit, Princess Alexandra Hospital, Woolloongabba, Queensland, Australia
| |
Collapse
|
6
|
Kwakman JA, Vos MC, Bruno MJ. Higher yield in duodenoscope cultures collected with addition of neutralizing agent. J Hosp Infect 2023; 132:28-35. [PMID: 36414167 DOI: 10.1016/j.jhin.2022.11.008] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Revised: 10/21/2022] [Accepted: 11/12/2022] [Indexed: 11/21/2022]
Abstract
AIM Microbiological cultures are the gold standard in the monitoring of duodenoscope reprocessing. However, many different sampling and culturing techniques are used, making it difficult to compare results. The latest Centers for Disease Control and Prevention protocol advises the use of a neutralizer to deactivate any remaining disinfectants in the samples. This study compared culturing results of duodenoscope samples collected with and without addition of a neutralizer. METHODS Six duodenoscopes were soiled with gut bacteria in a non-clinical experimental setting and reprocessed afterwards. Samples of the tip and working channel were collected immediately after decontamination or after drying. Dey-Engley (DE) broth was added as a neutralizer to the samples of four duodenoscopes; samples for the other two duodenoscopes were collected without the addition of DE broth. RESULTS Post-decontamination cultures were significantly more likely to be positive for growth of the applied micro-organisms in the group of samples with DE broth (88.1% vs 20.2%; P<0.0001). Post-drying samples were significantly more likely to be positive in the group of samples without DE broth (75.7% vs 33.4%; P<0.001). CONCLUSION The addition of DE broth to samples collected from wet duodenoscopes increases the yield of those cultures. Remaining disinfectants in wet duodenoscopes can lead to false-negative results. This can be overcome by adding a neutralizer, such as DE broth, to the samples. The higher yield after drying in the group without neutralizer could be due to biofilm formation in these two duodenoscopes, but this was not investigated. Standardization of the sampling method can help to compare both clinical and study results regarding duodenoscope contamination.
Collapse
Affiliation(s)
- J A Kwakman
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Centre, Rotterdam, the Netherlands; Department of Medical Microbiology and Infectious Diseases, Erasmus MC University Medical Centre, Rotterdam, the Netherlands.
| | - M C Vos
- Department of Medical Microbiology and Infectious Diseases, Erasmus MC University Medical Centre, Rotterdam, the Netherlands
| | - M J Bruno
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Centre, Rotterdam, the Netherlands
| |
Collapse
|
7
|
Waddingham W, Kamran U, Kumar B, Trudgill NJ, Tsiamoulos ZP, Banks M. Complications of diagnostic upper Gastrointestinal endoscopy: common and rare - recognition, assessment and management. BMJ Open Gastroenterol 2022; 9:bmjgast-2021-000688. [PMID: 36572454 PMCID: PMC9806027 DOI: 10.1136/bmjgast-2021-000688] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Accepted: 11/26/2022] [Indexed: 12/27/2022] Open
Abstract
A clear understanding of the potential complications or adverse events (AEs) of diagnostic endoscopy is an essential component of being an endoscopist. Creating a culture of safety and prevention of AEs should be part of routine endoscopy practice. Appropriate patient selection for procedures, informed consent, periprocedure risk assessments and a team approach, all contribute to reducing AEs. Early recognition, prompt management and transparent communication with patients are essential for the holistic and optimal management of AEs. In this review, we discuss the complications of diagnostic upper gastrointestinal endoscopy, including their recognition, treatment and prevention.
Collapse
Affiliation(s)
- William Waddingham
- Gastro-intestinal Services, University College London Hospitals NHS Foundation Trust, London, UK
| | - Umair Kamran
- Department of gastroenterology, Sandwell and West Birmingham Hospitals NHS Trust, Birmingham, UK
| | - Bhaskar Kumar
- Department of Surgery, Norfolk and Norwich University Hospitals NHS Foundation Trust, Norwich, UK
| | - Nigel J Trudgill
- Department of gastroenterology, Sandwell and West Birmingham Hospitals NHS Trust, Birmingham, UK
| | | | - Matthew Banks
- Gastro-intestinal Services, University College London Hospitals NHS Foundation Trust, London, UK
| |
Collapse
|
8
|
Goyal H, Larsen S, Perisetti A, Larsen NB, Ockert LK, Adamsen S, Tharian B, Thosani N. Gastrointestinal endoscope contamination rates - elevators are not only to blame: a systematic review and meta-analysis. Endosc Int Open 2022; 10:E840-E853. [PMID: 35692921 PMCID: PMC9187382 DOI: 10.1055/a-1795-8883] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/28/2021] [Accepted: 01/31/2022] [Indexed: 10/27/2022] Open
Abstract
Background and study aims Duodenoscopes that are contaminated due to inadequate reprocessing are well-documented. However, studies have demonstrated poor reprocessing of other kinds of endoscopes as well, including echoendoscopes, gastroscopes, and colonoscopes. We estimated the contamination rate beyond the elevator of gastrointestinal endoscopes based on available data. Methods We searched PubMed and Embase from January 1, 2010 to October 10, 2020, for studies investigating contamination rates of reprocessed gastrointestinal endoscopes. A random-effects model was used to calculate the contamination rate of patient-ready gastrointestinal endoscopes. Subgroup analyses were conducted to investigate differences among endoscope types, countries, and colony-forming unit (CFU) thresholds. Results Twenty studies fulfilled the inclusion criteria, including 1,059 positive cultures from 7,903 samples. The total contamination rate was 19.98 % ± 0.024 (95 % confidence interval [Cl]: 15.29 %-24.68 %; I 2 = 98.6 %). The contamination rates of colonoscope and gastroscope channels were 31.95 % ± 0.084 and 28.22 % ± 0.076, respectively. Duodenoscope channels showed a contamination rate of 14.41 % ± 0.029. The contamination rates among studies conducted in North America and Europe were 6.01 % ± 0.011 and 18.16% ± 0.053 %, respectively. The contamination rate among studies using a CFU threshold > 20 showed contamination of 30.36 % ± 0.094, whereas studies using a CFU threshold < 20 showed a contamination rate of 11 % ± 0.026. Conclusions On average, 19.98 % of reprocessed gastrointestinal endoscopes may be contaminated when used in patients and varies between different geographies. These findings highlight that the elevator mechanism is not the only obstacle when reprocessing reusable endoscopes; therefore, guidelines should recommend more surveillance of the endoscope channels as well.
Collapse
Affiliation(s)
- Hemant Goyal
- Center for Interventional Gastroenterology at UTHealth (iGUT), Division of Gastroenterology, Hepatology & Nutrition, McGovern Medical School, UTHealth, Houston, Texas, United States,Clinical Assistant Professor, Mercer University School of Medicine, Macon, Georgia, United States
| | | | - Abhilash Perisetti
- Division of Interventional Oncology & Surgical Endoscopy (IOSE). Parkview Cancer Institute, Wayne, Indiana, United States
| | | | - Lotte Klinten Ockert
- Center for Interventional Gastroenterology at UTHealth (iGUT), Division of Gastroenterology, Hepatology & Nutrition, McGovern Medical School, UTHealth, Houston, Texas, United States
| | - Sven Adamsen
- Center for Interventional Gastroenterology at UTHealth (iGUT), Division of Gastroenterology, Hepatology & Nutrition, McGovern Medical School, UTHealth, Houston, Texas, United States,Digestive Disease Center, Bispebjerg Hospital, University of Copenhagen, Copenhagen, Denmark
| | - Benjamin Tharian
- General and Advanced Endoscopy, Assoc. Prof of Medicine, University of Arkansas for Medical Sciences Little Rock, Arkansas, United States
| | - Nirav Thosani
- Center for Interventional Gastroenterology at UTHealth (iGUT), Division of Gastroenterology, Hepatology & Nutrition, McGovern Medical School, UTHealth, Houston, Texas, United States
| |
Collapse
|
9
|
Taunk P, Shimpi R, Singh R, Collins J, Muthusamy VR, Day LW. GI endoscope reprocessing: a comparative review of organizational guidelines and guide for endoscopy units and regulatory agencies. Gastrointest Endosc 2022; 95:1048-1059.e2. [PMID: 35303991 DOI: 10.1016/j.gie.2021.09.024] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/11/2021] [Accepted: 09/12/2021] [Indexed: 12/11/2022]
Affiliation(s)
- Pushpak Taunk
- Division of Gastroenterology, University of South Florida, Tampa, Florida, USA
| | - Rahul Shimpi
- Department of Gastroenterology, Duke University Medical Center, Durham, North Carolina, USA
| | - Ravi Singh
- Department of Gastroenterology, Great South Bay Endoscopy Center, LLC, East Patchogue, New York, USA
| | - James Collins
- Department of Digestive Diseases, Cleveland Clinic, Cleveland, Ohio, USA
| | | | - Lukejohn W Day
- Division of Gastroenterology and Hepatology, University of California San Francisco, San Francisco, California, USA
| |
Collapse
|
10
|
Does Anti-TNF-α Therapy Affect the Bacteriological Profile of Specimens Collected from Perianal Lesions? A Retrospective Analysis in Patients with Crohn's Disease. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19052892. [PMID: 35270584 PMCID: PMC8910208 DOI: 10.3390/ijerph19052892] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Revised: 02/23/2022] [Accepted: 02/28/2022] [Indexed: 02/04/2023]
Abstract
Anal abscesses and fistulas are potential complications of Crohn’s disease (CD). Chronic immunosuppression, loose stools, and poor wound healing in this population present challenges to the management of perianal diseases. The purpose of the study was to determine the predominant bacterial species found in specimens from perianal lesions causing anal abscess and/or fistula drainage in hospitalized patients, and to compare the number and type of microorganisms isolated from samples taken from patients undergoing biological therapy or traditionally treated. The outcomes of studies of patients treated for anal abscesses or fistulas from 2017 to 2019 were evaluated. Data obtained from medical records included culture and antibiotic sensitivity results of swabs from perianal lesions of isolated microorganisms. A total of 373 swabs were collected from perianal lesions during the analysis period, including 51 (49 positive samples) from patients with CD. The predominant pathogen was Escherichia coli (55%, p < 0.001), the second most common microorganism was Staphylococcus aureus (14.3%, p < 0.001). In vitro susceptibility testing showed E. coli, ESBL (strain with Extended Spectrum Beta-Lactamase) in five cases, S. aureus, MRSA (methicillin-resistant S. aureus -resistant to all beta-lactam antibiotics: penicillins with inhibitors, cephalosporins, monobactams, carbapenems, except for ceftaroline) in one sample. Biologic therapy does not affect the type of microorganisms isolated from perianal abscesses in patients with CD.
Collapse
|
11
|
Sharndama HC, Mba IE. Helicobacter pylori: an up-to-date overview on the virulence and pathogenesis mechanisms. Braz J Microbiol 2022; 53:33-50. [PMID: 34988937 PMCID: PMC8731681 DOI: 10.1007/s42770-021-00675-0] [Citation(s) in RCA: 72] [Impact Index Per Article: 36.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Accepted: 12/24/2021] [Indexed: 02/06/2023] Open
Abstract
Helicobacter pylori is an organism associated with ulcer disease and gastric cancer. The latter is one of the most prevalent malignancies and currently the fourth major cause of cancer-related deaths globally. The pathogen infects about 50% of the world population, and currently, no treatment ensures its total elimination. There has been an increase in our understanding of the pathophysiology and pathogenesis mechanisms of H. pylori over the years. H. pylori can induce several genetic alterations, express numerous virulence factors, and trigger diverse adaptive mechanisms during its adherence and colonization. For successful colonization and infection establishment, several effector proteins/toxins are released by the organism. Evidence is also available reporting spiral to coccoid transition as a unique tactic H. pylori uses to survive in the host's gastrointestinal tract (GIT). Thus, the virulence and pathogenicity of H. pylori are under the control of complex interplay between the virulence factors, host, and environmental factors. Expounding the role of the various virulence factors in H. pylori pathogenesis and clinical outcomes is crucial for vaccine development and in providing and developing a more effective therapeutic intervention. Here we critically reflect on H. pylori infection and delineate what is currently known about the virulence and pathogenesis mechanisms of H. pylori.
Collapse
Affiliation(s)
| | - Ifeanyi Elibe Mba
- Department of Microbiology, University of Nigeria, Nsukka, Enugu, Nigeria.
| |
Collapse
|
12
|
Impact of Infection Control Education on Gastrointestinal Endoscopy Procedural Staff. Gastroenterol Nurs 2022; 45:91-100. [PMID: 35220373 DOI: 10.1097/sga.0000000000000590] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/31/2020] [Accepted: 01/13/2021] [Indexed: 11/26/2022] Open
Abstract
To date, minimal research has been conducted on proper use of personal protective equipment and hand hygiene within endoscopy. The American Society for Gastrointestinal Endoscopy has developed guidelines for infection control within the endoscopy suite. A practice change based upon these guidelines was implemented. Education was provided to endoscopy procedural staff within a Midwestern hospital based upon the World Health Organization 5 Moments for Hand Hygiene initiative and included personal protective equipment. Knowledge, skills, and attitudes of the participant group were compared from paired pre- to posteducation surveys pertaining to hand hygiene and personal protective equipment. Observation of personal protective equipment use and hand hygiene implementation during procedures was also documented pre- to posteducation. The project results revealed both willingness to implement proper donning and doffing of personal protective equipment and improved technique as evidenced by improved observed technique with the endoscopy suite and moderately improved hand hygiene questionnaire results. Although conducted as a quality improvement project, clinical significance was found via observation following education. These practices can aid in reduction of organism transmission from patients to staff.
Collapse
|
13
|
Kwakman JA, Erler NS, Vos MC, Bruno MJ. Risk evaluation of duodenoscope-associated infections in the Netherlands calls for a heightened awareness of device-related infections: a systematic review. Endoscopy 2022; 54:148-155. [PMID: 33915575 DOI: 10.1055/a-1467-6294] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
BACKGROUND The risk of exogenous infections from endoscopic procedures is often cited as almost negligible (1 infection in 1.8 million procedures); however, this risk is based on older literature and does not seem to match the number of infectious outbreaks due to contaminated duodenoscopes reported after endoscopic retrograde cholangiopancreatography (ERCP). Using Dutch data, we aimed to estimate the minimum risk of duodenoscope-associated infection (DAI) and colonization (DAC) in patients undergoing ERCP. METHODS A systematic literature search identified all DAI outbreaks in the Netherlands reported between 2008 and 2019. Included cases were confirmed by molecular matching of patient and duodenoscope cultures. Risk ratios were calculated based on the total number of ERCPs performed during the study period. RESULTS Three outbreaks were reported and published between 2008 and 2018, including 21 confirmed DAI cases and 52 confirmed DAC cases. The estimated number of ERCPs performed during the same period was 181 209-227 006. The calculated minimum estimated DAI risk was approximately 0.01 % and the minimum estimated DAC risk was 0.023 %-0.029 %. CONCLUSIONS The estimated risk of DAI in Dutch ERCP practice was at least 180 times higher than previously published risk estimates. The actual risk is likely to be (much) higher due to underreporting of infections caused by multidrug-resistant organisms and sensitive bacteria. Greater awareness by healthcare personnel involved in endoscopy and endoscope cleaning is required, as well as innovative technical solutions to contain and ultimately eliminate DAIs.
Collapse
Affiliation(s)
- Judith A Kwakman
- Department of Gastroenterology and Hepatology, Erasmus Medical Center, Rotterdam, the Netherlands.,Department of Microbiology, Erasmus Medical Center, Rotterdam, the Netherlands
| | - Nicole S Erler
- Department of Biostatistics, Erasmus Medical Center, Rotterdam, the Netherlands
| | - Margreet C Vos
- Department of Microbiology, Erasmus Medical Center, Rotterdam, the Netherlands
| | - Marco J Bruno
- Department of Gastroenterology and Hepatology, Erasmus Medical Center, Rotterdam, the Netherlands
| |
Collapse
|
14
|
Kwakman JA, Rauwers AW, Klaassen CHW, Bruno MJ, Vos MC. Investigation of possible transmission of a susceptible microorganism through a contaminated duodenoscope; a case report. Antimicrob Resist Infect Control 2021; 10:127. [PMID: 34454611 PMCID: PMC8403455 DOI: 10.1186/s13756-021-00996-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Accepted: 08/20/2021] [Indexed: 02/05/2023] Open
Abstract
BACKGROUND Despite compliance to extensive reprocessing protocols, duodenoscopes have been linked to outbreaks of susceptible and multi-drug resistant organisms (MDRO) due to persistent duodenoscope contamination. Duodenoscope-associated infections (DAIs) based on transmission of susceptible microorganisms are likely to be underreported due to detection bias. CASE PRESENTATION We describe the retrospective detection of a DAI case caused by a susceptible microorganism which at the time of clinical infection was not recognized as such. During 2017 and 2018, duodenoscopes were cultured on a daily basis due to research activities. While analyzing this data, it was found that a duodenoscope had been contaminated with Enterobacter cloacae complex over a period of 3 months. We checked whether patients treated with this duodenoscope had developed infections and found one patient with an E. cloacae cholangitis 3 months after the ERCP (Endoscopic retrograde cholangiopancreaticography) procedure. The isolates on the duodenoscope and in the patients' blood culture were indistinguishable by amplified fragment length polymorphism (AFLP). By classical multi-locus sequence typing (MLST), both strains were of the same (but novel) sequence type. Application of whole genome MLST showed 93 (out of 3757) allelic differences. CONCLUSION This case report describes a plausible link between a contaminated duodenoscope and a patient infection with E. cloacae. Transmission of susceptible E. cloacae was highly suspected from AFLP and MLST results; by WGS, 93 allelic differences were found which proves closely related strains. This report shows that DAIs by susceptible microorganisms can be easily missed and therefore its true prevalence remains underscored.
Collapse
Affiliation(s)
- Judith A Kwakman
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Dr. Molewaterplein 40, Mailbox 2040, Rotterdam, The Netherlands. .,Department of Medical Microbiology and Infectious Diseases, Erasmus MC University Medical Center, Rotterdam, The Netherlands.
| | - Arjan W Rauwers
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Dr. Molewaterplein 40, Mailbox 2040, Rotterdam, The Netherlands.,Department of Medical Microbiology and Infectious Diseases, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Corné H W Klaassen
- Department of Medical Microbiology and Infectious Diseases, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Marco J Bruno
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Dr. Molewaterplein 40, Mailbox 2040, Rotterdam, The Netherlands
| | - Margreet C Vos
- Department of Medical Microbiology and Infectious Diseases, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| |
Collapse
|
15
|
Gruszecka J, Filip R, Gutkowska D. The State of Microbiological Cleanliness of Surfaces and Equipment of an Endoscopic Examination Laboratory-Data from a Reference Tertiary Clinical Endoscopy Center in Southern Poland. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph18126346. [PMID: 34208169 PMCID: PMC8296163 DOI: 10.3390/ijerph18126346] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 04/21/2021] [Revised: 06/02/2021] [Accepted: 06/07/2021] [Indexed: 11/16/2022]
Abstract
The increasing number of endoscopic procedures performed and their increasing invasiveness mean that endoscopy of the gastrointestinal tract is associated with the risk of transmitting pathogenic microorganisms through infected equipment or contact with other patients and medical staff. In order to ensure protection of the health of both patients and medical staff, endoscopy laboratories should meet high hygiene standards. The results of tests of the microbiological cleanliness of surfaces and equipment of an endoscopic examination laboratory performed in the period from January to December 2019 at the Provincial Clinical Hospital No. 2 in Rzeszow were assessed retrospectively. Samples for testing were collected by swabbing from places where microbiological contamination was the most likely and cleaning was the most difficult. In the analyzed period, a total of 86 samples were collected for microbiological tests, of which positive results accounted for 6.9%. Positive results were obtained mainly from swabs collected from wet surfaces (66.7%). Most of the isolated microorganisms were Gram-negative bacteria (66.7% of all positive tests) and they were: Acinetobacter junii, Ralstonia pickettii, and Achromobacter denitrificans. The condition of the microbiological cleanliness of the surfaces and equipment of the endoscopic examination laboratory was satisfactory. A very low level of microbiological contamination of the tested items indicates occasional shortcomings in the decontamination processes. Since microorganisms isolated from the collected samples may be the cause of infection in patients and medical personnel, it is necessary to verify the decontamination procedures applied and to continue periodic microbiological monitoring of their effectiveness.
Collapse
Affiliation(s)
- Jolanta Gruszecka
- Institute of Health Sciences, Medical College of Rzeszow University, 35-310 Rzeszow, Poland;
- Department of Clinical Microbiology, Clinical Hospital No. 2 im. Św. Jadwigi Królowej, 35-301 Rzeszow, Poland
- Correspondence:
| | - Rafał Filip
- Faculty of Medicine, Medical College of Rzeszow University, 35-959 Rzeszow, Poland;
- Department of Gastroenterology with IBD Unit of Clinical Hospital 2 im. Św. Jadwigi Królowej, 35-301 Rzeszow, Poland
| | - Dorota Gutkowska
- Institute of Health Sciences, Medical College of Rzeszow University, 35-310 Rzeszow, Poland;
| |
Collapse
|
16
|
STANDARDS OF INFECTION PREVENTION IN REPROCESSING FLEXIBLE GASTROINTESTINAL ENDOSCOPES. Gastroenterol Nurs 2021; 43:E142-E158. [PMID: 32487962 DOI: 10.1097/sga.0000000000000536] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
17
|
Josephs-Spaulding J, Singh OV. Medical Device Sterilization and Reprocessing in the Era of Multidrug-Resistant (MDR) Bacteria: Issues and Regulatory Concepts. FRONTIERS IN MEDICAL TECHNOLOGY 2021; 2:587352. [PMID: 35047882 PMCID: PMC8757868 DOI: 10.3389/fmedt.2020.587352] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2020] [Accepted: 11/10/2020] [Indexed: 12/20/2022] Open
Abstract
The emergence of multidrug-resistant (MDR) bacteria threatens humans in various health sectors, including medical devices. Since formal classifications for medical device sterilization and disinfection were established in the 1970's, microbial adaptation under adverse environmental conditions has evolved rapidly. MDR microbial biofilms that adhere to medical devices and recurrently infect patients pose a significant threat in hospitals. Therefore, it is essential to mitigate the risk associated with MDR outbreaks by establishing novel recommendations for medical device sterilization, in a world of MDR. MDR pathogens typically thrive on devices with flexible accessories, which are easily contaminated with biofilms due to previous patient use and faulty sterilization or reprocessing procedures. To prevent danger to immunocompromised individuals, there is a need to regulate the classification of reprocessed medical device sterilization. This article aims to assess the risks of improper sterilization of medical devices in the era of MDR when sterilization procedures for critical medical devices are not followed to standard. Further, we discuss key regulatory recommendations for consistent sterilization of critical medical devices in contrast to the risks of disinfection reusable medical devices.
Collapse
Affiliation(s)
- Jonathan Josephs-Spaulding
- Department of Environmental Health and Engineering, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD, United States
| | - Om V. Singh
- Advance Academic Program, The Johns Hopkins University, Washington, DC, United States
- Technology Science Group (TSG) Consulting Inc., A Science Group Company, Washington, DC, United States
| |
Collapse
|
18
|
Day LW, Muthusamy VR, Collins J, Kushnir VM, Sawhney MS, Thosani NC, Wani S. Multisociety guideline on reprocessing flexible GI endoscopes and accessories. Gastrointest Endosc 2021; 93:11-33.e6. [PMID: 33353611 DOI: 10.1016/j.gie.2020.09.048] [Citation(s) in RCA: 55] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Accepted: 09/30/2020] [Indexed: 02/07/2023]
Affiliation(s)
- Lukejohn W Day
- Division of Gastroenterology and Hepatology, University of California San Francisco, San Francisco, California, USA
| | | | - James Collins
- Department of Digestive Diseases, Cleveland Clinic, Cleveland, Ohio, USA
| | - Vladimir M Kushnir
- Division of Gastroenterology, Washington University, St Louis, Missouri, USA
| | - Mandeep S Sawhney
- Division of Gastroenterology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
| | - Nirav C Thosani
- Division of Gastroenterology, Hepatology and Nutrition, McGovern Medical School, UTHealth, Houston, Texas, USA
| | - Sachin Wani
- Division of Gastroenterology and Hepatology, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| |
Collapse
|
19
|
COVID-19 Emergency Management: From the Reorganization of the Endoscopy Service to the Verification of the Reprocessing Efficacy. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17218142. [PMID: 33158126 PMCID: PMC7662711 DOI: 10.3390/ijerph17218142] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Revised: 10/26/2020] [Accepted: 11/02/2020] [Indexed: 12/14/2022]
Abstract
Microbiological surveillance carried out in order to verify the effectiveness of endoscope reprocessing does not include the research of viruses, although endoscopes may be associated with the transmission of viral infections. This paper reports the experience of the University Hospital of Pisa in managing the risk from severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) during an endoscopy. A review of the reprocessing procedure was conducted to assess whether improvement actions were needed. To verify the reprocessing efficacy, a virological analysis was conducted both before and after the procedure. Five bronchoscopes and 11 digestive endoscopes (6 gastroscopes and 5 colonoscopes) were sampled. The liquid samples were subjected to concentration through the use of the Macrosep Advance Centrifugal Devices (PALL Life Sciences, Port Washington, NY, USA) and subsequently analyzed using the cobas® SARS-CoV-2 Test (Roche Diagnostics, Basel, Switzerland), together with eSwab 490 CE COPAN swabs (COPAN, Brescia, Italy), which were used to sample surfaces. In accordance with the first ordinance regarding the coronavirus disease 2019 (COVID-19) emergency issued by the Tuscany Region in March 2020, a procedure dedicated to the management of the COVID-19 emergency in endoscopic practices was prepared, including the reprocessing of endoscopes. The virological analysis carried out on samples collected from endoscopes after reprocessing gave negative results, as well as on samples collected on the endoscopy column surfaces and the two washer-disinfectors that were dedicated to COVID-19 patients. The improvement in endoscope reprocessing implemented during the COVID-19 emergency was effective in ensuring the absence of SARS-CoV-2, thus reducing the risk of infections after an endoscopy on COVID-19 patients.
Collapse
|
20
|
Larsen S, Russell RV, Ockert LK, Spanos S, Travis HS, Ehlers LH, Mærkedahl A. Rate and impact of duodenoscope contamination: A systematic review and meta-analysis. EClinicalMedicine 2020; 25:100451. [PMID: 32954234 PMCID: PMC7486302 DOI: 10.1016/j.eclinm.2020.100451] [Citation(s) in RCA: 45] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND Multiple infection outbreaks have been linked to contaminated duodenoscopes worldwide. However, the contamination rate of patient-ready duodenoscopes varies highly amongst published studies testing this subject. We aimed to estimate the contamination rate of reprocessed patient-ready duodenoscopes for endoscopic retrograde cholangio-pancreatography (ERCP) based on currently available data. METHODS We searched the PubMed and Embase databases from January 1, 2010 until March 10, 2020, for citations investigating contamination rates of reprocessed patient-ready duodenoscopes. Studies not assessing other types of endoscopes than duodenoscopes were excluded from the analysis. Study eligibility and data extraction was evaluated by three reviewers independently. A random-effects model (REM) based on the proportion distribution was used to calculate the pooled total contamination rate of reprocessed patient-ready duodenoscopes. Subgroup analyses were carried out to assess contamination rates when using different reprocessing methods by comparing single high-level disinfection (HLD) with double HLD and ethylene oxide (EtO) gas sterilization. Additionally, we investigated the contamination rate between studies conducted following an outbreak compared to non-outbreak-initiated studies. FINDINGS We identified 15 studies that fulfilled the inclusion, which included 925 contaminated duodenoscopes from 13,112 samples. The calculated total weighted contamination rate was 15.25% ± 0.018 (95% confidence interval [Cl]: 11.74% - 18.75%). The contamination rate after only using HLD was 16.14% ± 0.019 (95% Cl: 12.43% - 19.85%) and after using either dHLD or EtO the contamination rate decreased to 9.20% ± 0.025 (95% Cl: 4.30% - 14.10%). Studies conducted following an outbreak (n=4) showed a 5.72% ± 0.034 (95% Cl: 0.00% - 12.43%) contamination rate, and non-outbreak-initiated studies (n=11) revealed a contamination rate of 21.50% ± 0.031 (95% Cl: 15.35% - 27.64%). INTERPRETATION This is the first meta-analysis to estimate the contamination rate of patient-ready duodenoscopes used for ERCP. Based on the available literature, our analysis demonstrates that there is a 15.25% contamination rate of reprocessed patient-ready duodenoscopes. Additionally, the analysis indicates that dHLD and EtO reprocessing methods are superior to single HLD but still not efficient in regards to cleaning the duodenoscopes properly. Furthermore, studies conducted following an outbreak did not entail a higher contamination rate compared to non-outbreak-initiated studies. FUNDING The authors received no financial support for the research, authorship, and/or publication of this article.
Collapse
Key Words
- AGA, American Gastroenterological Association
- AORN, The Joint Commission and The Association of Perioperative Registered Nurses
- Bacterial*
- CDC, Center for Disease Control and Prevention
- CFU, colony-forming units
- CRE, carbapenem-resistant Enterobacteriaceae
- Cl, confidence interval
- Cross infection
- Drug Resistance
- Duodenoscopes
- ERCI, Environmental Risk Communications, Inc.
- ERCP, endoscopic retrograde cholangio-pancreatography
- Equipment contamination
- EtO, ethylene oxide
- FDA, Food & Drug Administration
- HLD, high-level disinfection
- Infection Control
- MDR, multi-drug-resistant
- MeSH, medical subject headings
- Multiple
- PRISMA, Preferred Reporting Items for Systematic Reviews and Meta-Analyses
- REM, random-effects model
- dHLD, double high-level disinfection
Collapse
Affiliation(s)
- Sara Larsen
- Ambu A/S, Ambu A/S, Baltorpbakken 13, 2750 Ballerup, Denmark
| | | | | | - Stephen Spanos
- Anesthesia and Acute Pain Department of Anesthesia University of Utah Primary Children's Hospital, United States
| | | | - Lars Holger Ehlers
- Department of Business and Management, Danish Center for Healthcare Improvements, Aalborg University, Aalborg, Denmark
| | | |
Collapse
|
21
|
Cheung DY, Jang BI, Kim SW, Kim JH, Kim HK, Shin JE, Yoon WJ, Lee YK, Chung KH, Cho SJ, Shin HP, Cho SY, Shin WG, Choi KD, Kim BW, Kwon JG, Yang HC, Gweon TG, Kim HG, Ahn DW, Cho KB, Kim SH, Hwang KH, Im HH. Multidisciplinary and Multisociety Practice Guideline on Reprocessing Flexible Gastrointestinal Endoscopes and Endoscopic Accessories. Clin Endosc 2020; 53:276-285. [PMID: 32506894 PMCID: PMC7280845 DOI: 10.5946/ce.2020.106] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Revised: 04/27/2020] [Accepted: 04/28/2020] [Indexed: 11/22/2022] Open
Abstract
The area of endoscopic application has been continuously expanded since its introduction in the last century and the frequency of its use also increased stiffly in the last decades. Because gastrointestinal endoscopy is naturally exposed to diseased internal organs and contact with pathogenic materials, endoscopy mediated infection or disease transmission becomes a major concern in this field. Gastrointestinal endoscopy is not for single use and the proper reprocessing process is a critical factor for safe and reliable endoscopy procedures. What needed in these circumstances is a practical guideline for reprocessing the endoscope and its accessories which is feasible in the real clinical field to guarantee acceptable prevention of pathogen transmission. This guideline contains principles and instructions of the reprocessing procedure according to the step by step. And it newly includes general information and updated knowledge about endoscopy-mediated infection and disinfection. Multiple societies and working groups participated to revise; Korean Association for the Study of the Liver, the Korean Society of Infectious Diseases, Korean College of Helicobacter and Upper Gastrointestinal Research, the Korean Society of Gastroenterology, Korean Society of Gastrointestinal Cancer, Korean Association for the Study of Intestinal Diseases, Korean Pancreatobiliary Association, the Korean Society of Gastrointestinal Endoscopy Nurses and Associates and Korean Society of Gastrointestinal Endoscopy. Through this cooperation, we enhanced communication and established a better concordance. We still need more researches in this field and fill up the unproven area. And our guidelines will be renewed accordingly.
Collapse
Affiliation(s)
- Dae Young Cheung
- Department of Internal Medicine, The Catholic University of Korea College of Medicine, Seoul, Korea
| | - Byung Ik Jang
- Department of Internal Medicine, Yeungnam University College of Medicine, Daegu, Korea
| | - Sang Wook Kim
- Department of Internal Medicine, Jeonbuk National University Medical School, Jeonju, Korea
| | - Jie-Hyun Kim
- Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Kroea
| | - Hyung Keun Kim
- Department of Internal Medicine, The Catholic University of Korea College of Medicine, Seoul, Korea
| | - Jeong Eun Shin
- Department of Internal Medicine, Dankook University College of Medicine, Cheonan, Korea
| | - Won Jae Yoon
- Department of Internal Medicine, Ewha Womans University College of Medicine, Seoul, Korea
| | - Yong Kang Lee
- Department of Internal Medicine, National Health Insurance Service Ilsan Hospital, Goyang, Korea
| | - Kwang Hyun Chung
- Department of Internal Medicine, Eulji University School of Medicine, Daejeon, Korea
| | - Soo-Jeong Cho
- Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Korea
| | - Hyun Phil Shin
- Department of Internal Medicine, Kyung Hee University School of Medicine, Seoul, Korea
| | - Sun Young Cho
- Department of Internal Medicine, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Woon Geon Shin
- Department of Internal Medicine, Hallym University College of Medicine, Seoul, Korea
| | - Kee Don Choi
- Department of Internal Medicine, University of Ulsan College of Medicine, Seoul, Korea
| | - Byung-Wook Kim
- Department of Internal Medicine, The Catholic University of Korea College of Medicine, Seoul, Korea
| | - Joong Goo Kwon
- Department of Internal Medicine, Daegu Catholic University School of Medicine, Daegu, Korea
| | - Hee Chan Yang
- Department of Internal Medicine, Jeonbuk National University Medical School, Jeonju, Korea
| | - Tae-Geun Gweon
- Department of Internal Medicine, The Catholic University of Korea College of Medicine, Seoul, Korea
| | - Hyun Gun Kim
- Department of Internal Medicine, Soonchunhyang University College of Medicine, Seoul, Korea
| | - Dong-Won Ahn
- Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Korea
| | - Kwang Bum Cho
- Department of Internal Medicine, Keimyung University School of Medicine, Daegu, Korea
| | | | - Kyong Hwa Hwang
- The Catholic University of Korea Seoul St. Mary’s Hospital, Seoul, Korea
| | - Hee Hyuk Im
- Soon Chun Hyang University Seoul Hospital, Seoul, Korea
| |
Collapse
|
22
|
STANDARD OF INFECTION PREVENTION IN THE GASTROENTEROLOGY SETTING. Gastroenterol Nurs 2020; 43:E84-E97. [PMID: 32251230 DOI: 10.1097/sga.0000000000000519] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
23
|
Larsen S, Holm JH, Sauer TN, Andersen C. A Cost-Effectiveness Analysis Comparing the VivaSight Double-Lumen Tube and a Conventional Double-Lumen Tube in Adult Patients Undergoing Thoracic Surgery Involving One-Lung Ventilation. PHARMACOECONOMICS - OPEN 2020; 4:159-169. [PMID: 31297752 PMCID: PMC7018861 DOI: 10.1007/s41669-019-0163-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
BACKGROUND One-lung ventilation (OLV) procedures are essential for most thoracic surgeries, and the most common method is intubation with a conventional double-lumen tube (cDLT) and bronchoscopy to verify correct tube placement. OBJECTIVE The objective of this study was to conduct a cost-effectiveness analysis comparing the VivaSight double-lumen tube (DL) and a cDLT for OLV procedures. METHODS A cost-effectiveness analysis was conducted from a healthcare sector perspective in Denmark using a decision analytic model to assess the potential effects and costs of using VivaSight-DL as an alternative to a cDLT with a reusable bronchoscope. Costs were determined using a micro-costing approach. The effectiveness measure was the number of times that fiberoptic confirmation of the tube placement during intubation or surgery was unnecessary and thus avoided. The effectiveness input was from a randomized controlled trial (n = 52). Both deterministic and probabilistic sensitivity analyses were conducted to assess the robustness of the results. RESULTS Fiberoptic confirmation of tube placement was only necessary in two (6.66%) procedures using VivaSight-DL. The cost of using VivaSight-DL was $US299.96 per procedure versus $US347.61 for a cDLT with a reusable bronchoscope. The incremental cost-effectiveness ratio was - $US51.06 per bronchoscopy avoided. The base-case analysis indicated that the use of VivaSight-DL was cost effective compared with the use of a cDLT with reusable bronchoscope. Sensitivity analyses showed that the results were robust and that VivaSight-DL was more effective and less costly. CONCLUSION This study suggests that VivaSight-DL is associated with cost savings and reductions in bronchoscope use to verify correct tube placement. The conclusion is based on the results from a single institution. To clarify whether VivaSight-DL is cost effective in larger or global clinical settings, further economic evaluations should be performed.
Collapse
Affiliation(s)
- Sara Larsen
- Aalborg University, Niels Jernes Vej 10, 9220, Aalborg, Denmark.
| | | | | | - Claus Andersen
- Odense University Hospital, J.B. Winsløws Vej 4, 5000, Odense, Denmark
| |
Collapse
|
24
|
Mati MLDM, Guimarães NR, Magalhães PP, Farias LDM, de Oliveira AC. Enzymatic detergent reuse in gastroscope processing: a potential source of microorganism transmission. Rev Lat Am Enfermagem 2019; 27:e3211. [PMID: 31826156 PMCID: PMC6896813 DOI: 10.1590/1518-8345.3101.3211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2019] [Accepted: 08/01/2019] [Indexed: 11/25/2022] Open
Abstract
OBJECTIVE to evaluate the potential contamination of enzymatic detergent from its reuse and to identify the microbiological profile in the solution used to clean gastrointestinal endoscopic devices. METHOD cross-sectional study based on microbiological analysis of 76 aliquots of 19 different enzymatic detergent solutions used to clean endoscopic devices. The aliquots were homogenized, subjected to Millipore® 0.45 µm membrane filtration and the presumptive identification of microorganisms was performed by biochemical-physiological methods according to previously established specific bacterial groups that are of clinical and epidemiological relevance. RESULTS the mean values, as well as the standard deviation and the median, of the enzymatic detergent microbial load increased as the solution was reused. There was a significant difference between the means of after first use and after fifth reuse. A total of 97 microorganisms were identified, with predominance of the coagulase-negative Staphylococcus, Pseudomonas spp., Klebsiella spp., Enterobacter spp. genus, and Escherichia coli species. CONCLUSION the reuse of the enzymatic detergent solution is a risk to the safe processing of endoscopic devices, evidenced by its contamination with pathogenic potential microorganisms, since the enzymatic detergent has no bactericidal property and can contribute as an important source for outbreaks in patients under such procedures.
Collapse
Affiliation(s)
| | - Natália Rocha Guimarães
- Universidade Federal de Minas Gerais, Instituto de Ciências Biológicas, Belo Horizonte, MG, Brazil
- Scholarship holder at the Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES), Brazil
| | - Paula Prazeres Magalhães
- Universidade Federal de Minas Gerais, Instituto de Ciências Biológicas, Belo Horizonte, MG, Brazil
| | - Luiz de Macêdo Farias
- Universidade Federal de Minas Gerais, Instituto de Ciências Biológicas, Belo Horizonte, MG, Brazil
| | | |
Collapse
|
25
|
Rauwers AW, Kwakman JA, Vos MC, Bruno MJ. Endoscope-associated infections: A brief summary of the current state and views toward the future. TECHNIQUES IN GASTROINTESTINAL ENDOSCOPY 2019. [DOI: 10.1016/j.tgie.2019.04.006] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
|
26
|
Shin JE, Jung Y, Lee JH, Son BK, Jang JY, Kim HK, Jang BI. Updates on the Disinfection and Infection Control Process of the Accredited Endoscopy Unit. Clin Endosc 2019; 52:443-450. [PMID: 31591281 PMCID: PMC6785420 DOI: 10.5946/ce.2019.173] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/02/2019] [Accepted: 09/23/2019] [Indexed: 11/16/2022] Open
Abstract
A thorough disinfection and infection control process associated with gastrointestinal endoscopy is highly important for the health and safety of the examinee and the medical staff involved in the procedure. Endoscopic reprocessing and disinfection are two of the most important steps in quality control of endoscopy. In 2019, the Korean Society of Gastrointestinal Endoscopy updated the Accreditation of Qualified Endoscopy Unit assessment items for these quality indicators. Assessment of disinfection and infection control comprises 28 mandatory items in the categories of disinfection education, pre-cleaning, cleaning, disinfection, rinsing, drying, reprocessing, storage, endoscopic accessories, water bottle and connectors, space/facilities, personal protective equipment, disinfection ledger, and regulations regarding infection control and disinfection. The updated Accreditation of Qualified Endoscopy Unit assessment items are useful for improving the quality of endoscopy by ensuring thorough inspection of endoscopic disinfection and infection control.
Collapse
Affiliation(s)
- Jeong Eun Shin
- Department of Internal Medicine, Dankook University College of Medicine, Cheonan, Korea
| | - Yunho Jung
- Department of Internal Medicine, Soonchunhyang University College of Medicine, Cheonan, Korea
| | - Jeong Hoon Lee
- Department of Internal Medicine, University of Ulsan College of Medicine, Seoul, Korea
| | - Byoung Kwan Son
- Department of Internal Medicine, Eulji University College of Medicine, Seoul, Korea
| | - Jae-Young Jang
- Department of Internal Medicine, Kyung Hee University College of Medicine, Seoul, Korea
| | - Hyung-Keun Kim
- Division of Gastroenterology, Department of Internal Medicine, Uijeongbu St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu, Korea
| | - Byung Ik Jang
- Department of Internal Medicine, Yeungnam University College of Medicine, Daegu, Korea
| |
Collapse
|
27
|
Barakat MT, Huang RJ, Banerjee S. Comparison of automated and manual drying in the elimination of residual endoscope working channel fluid after reprocessing (with video). Gastrointest Endosc 2019; 89:124-132.e2. [PMID: 30148992 PMCID: PMC6748329 DOI: 10.1016/j.gie.2018.08.033] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/26/2018] [Accepted: 08/09/2018] [Indexed: 02/08/2023]
Abstract
BACKGROUND AND AIMS Residual fluid within endoscope working channels after reprocessing may promote growth of pathogens. Current reprocessing guidelines therefore recommend endoscope drying with administration of forced filtered air; however, the duration and modality of administered air are not specified. The new DriScope Aid device enables automated administration of filtered air at controlled pressure through all internal endoscope channels. We systematically compared, for the first time, the impact of manual drying and automated drying on retained working channel fluid and bioburden after reprocessing. METHODS We assessed for residual working channel fluid after reprocessing and/or drying by using the SteriCam borescope. Drying was performed either manually (forced filtered air) or was automated (DriScope Aid) for either 5 or 10 minutes. Adenosine triphosphate (ATP) bioluminescence testing was performed on working channel rinsates after drying, to evaluate for residual bioburden. RESULTS Significantly more fluid droplets were evident after manual drying (4.55 ± 6.14) than with automated device-facilitated drying for either 5 minutes (0.83 ± 1.29; P = .007) or 10 minutes (0 ± 0; P = .001). ATP bioluminescence values were higher for manual drying compared with automated drying at 48 hours (P = .001) and 72 hours (P = .014) after reprocessing. CONCLUSIONS We demonstrate significantly fewer water droplets and delayed ATP bioluminescence values within endoscope working channels after automated drying compared with manual drying. In particular, virtually no retained fluid was evident within endoscope working channels after automated drying for 10 minutes. These findings support recommendations for automation of as many reprocessing steps as possible. Automated drying may decrease the risk of transmission of infection related to endoscopy.
Collapse
|
28
|
McCafferty CE, Aghajani MJ, Abi-Hanna D, Gosbell IB, Jensen SO. An update on gastrointestinal endoscopy-associated infections and their contributing factors. Ann Clin Microbiol Antimicrob 2018; 17:36. [PMID: 30314500 PMCID: PMC6182826 DOI: 10.1186/s12941-018-0289-2] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2018] [Accepted: 10/06/2018] [Indexed: 11/10/2022] Open
Abstract
INTRODUCTION During clinical use, gastrointestinal endoscopes are grossly contaminated with patient's native flora. These endoscopes undergo reprocessing to prevent infectious transmission upon future use. Endoscopy-associated infections and outbreaks have been reported, with a recent focus on the transmission of multi-drug resistant organisms. This review aims to provide an update on endoscopy-associated infections, and the factors contributing to their occurrence. METHODS PubMed, ScienceDirect, and CINAHL were searched for articles describing gastrointestinal endoscopy-associated infections and outbreaks published from 2008 to 2018. Factors contributing to their occurrence, and the outcomes of each outbreak were also examined. RESULTS This review found 18 articles, 16 of which described duodenoscope-associated infections, and the remaining two described colonoscope- and gastroscope-associated infection respectively. Outbreaks were reported from the United States, France, China, Germany, the Netherlands and the United Kingdom. The causative organisms reported were Klebsiella pneumoniae, Pseudomonas aeruginosa, Escherichia coli and Salmonella enteritidis. CONCLUSIONS A number of factors, including lapses in reprocessing, biofilm formation, endoscope design issues and endoscope damage, contribute to gastrointestinal endoscopy associated infection. Methods of improving endoscope reprocessing, screening for contamination and evaluating endoscope damage may be vital to preventing future infections and outbreaks.
Collapse
Affiliation(s)
- Charles Eugenio McCafferty
- Ingham Institute for Applied Medical Research, 1 Campbell Street, Sydney, NSW, 2560, Australia. .,Western Sydney University, School of Medicine, Sydney, 2560, Australia.
| | - Marra Jai Aghajani
- Ingham Institute for Applied Medical Research, 1 Campbell Street, Sydney, NSW, 2560, Australia.,Western Sydney University, School of Medicine, Sydney, 2560, Australia
| | - David Abi-Hanna
- Department of Gastroenterology and Hepatology, Liverpool Hospital, Sydney, 2170, Australia.,School of Medicine, University of New South Wales, Sydney, 2033, Australia
| | | | - Slade Owen Jensen
- Ingham Institute for Applied Medical Research, 1 Campbell Street, Sydney, NSW, 2560, Australia.,Western Sydney University, School of Medicine, Sydney, 2560, Australia
| |
Collapse
|
29
|
Folch E, Kheir F, Mahajan A, Alape D, Ibrahim O, Shostak E, Majid A. Bronchoscope-Guided Percutaneous Endoscopic Gastrostomy Tube Placement by Interventional Pulmonologists: A Feasibility and Safety Study. J Intensive Care Med 2018; 35:851-857. [PMID: 30244635 DOI: 10.1177/0885066618800275] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
BACKGROUND Percutaneous endoscopic gastrostomy (PEG) tube placement is a procedure frequently done in the intensive care unit. The use of a traditional endoscope can be difficult in cases of esophageal stenosis and theoretically confers an increased risk of infection due to its complex architecture. We describe a technique using the bronchoscope, which allows navigation through stenotic esophageal lesions and also minimizes the risk of endoscopy-associated infections. METHODS Prospective series of patients who had PEG tube placement guided by a bronchoscope. Procedural outcomes including successful placement, duration of the entire procedure, time needed for passage of the bronchoscope from the oropharynx to the major curvature, PEG tube removal rate, and mortality were collected. Procedural adverse events, including infections and long-term PEG-related complications, were recorded. RESULTS A total of 84 patients underwent bronchoscope-guided PEG tube placement. Percutaneous endoscopic gastrostomy tube insertion was completed successfully in 82 (97.6%) patients. Percutaneous endoscopic gastrostomy tube placement was performed immediately following percutaneous tracheostomy in 82.1%. Thirty-day mortality and 1-year mortality were 11.9% and 31%, respectively. Overall, minor complications occurred in 2.4% of patients, while there were no major complications. No serious infectious complications were identified and no endoscope-associated hospital acquired infections were documented. CONCLUSIONS The use of the bronchoscope can be safely and effectively used for PEG tube placement. The use of bronchoscope rather than a gastroscope has several advantages, which include the ease of navigating through complex aerodigestive disorders such as strictures and fistulas as well as decreased health-care utilization. In addition, it may have a theoretical advantage of minimizing infections related to complex endoscopes.
Collapse
Affiliation(s)
- Erik Folch
- Division of Pulmonary and Critical Care Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Fayez Kheir
- Division of Pulmonary Diseases, Critical Care and Environmental Medicine, Tulane University Health Sciences Center, New Orleans, LA, USA.,Division of Thoracic Surgery and Interventional Pulmonology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Amit Mahajan
- Interventional Pulmonology, Inova Healthcare, Falls Church, VA, USA
| | - Daniel Alape
- Division of Thoracic Surgery and Interventional Pulmonology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Omar Ibrahim
- Interventional Pulmonology, University of Connecticut, Mansfield, CT, USA
| | - Eugene Shostak
- Interventional Pulmonology, NewYork-Presbyterian/Weill Cornell, New York, NY, USA
| | - Adnan Majid
- Division of Thoracic Surgery and Interventional Pulmonology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
30
|
Grein JD, Murthy RK. New Developments in the Prevention of Gastrointestinal Scope-Related Infections. Infect Dis Clin North Am 2018; 32:899-913. [PMID: 30241713 DOI: 10.1016/j.idc.2018.06.008] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Gastrointestinal endoscopes are used for diagnostic and therapeutic purposes and are the most common medical device implicated in health care-associated outbreaks. Infections can be divided into endogenous or exogenous. Exogenous infections were associated with lapses in reprocessing. Recent outbreaks have occurred despite compliance with reprocessing guidelines and highlight the challenges with clearance of all organisms from the duodenoscopes and the potential role of biofilms in hindering adequate reprocessing. This review provides an overview of recent developments and the current understanding of the key contributing factors related to gastrointestinal endoscope-related infections and current approaches to identify and prevent these complications.
Collapse
Affiliation(s)
- Jonathan D Grein
- Department of Hospital Epidemiology, Division of Infectious Diseases, Cedars-Sinai Medical Center, 8635 W 3rd Street, Suite 1150W, Los Angeles, CA, USA
| | - Rekha K Murthy
- Department of Hospital Epidemiology, Division of Infectious Diseases, Cedars-Sinai Medical Center, 8635 W 3rd Street, Suite 1150W, Los Angeles, CA, USA; Department of Medical Affairs, Cedars-Sinai Medical Center, 8700 Beverly Boulevard, Suite 2211, Los Angeles, CA 90048, USA.
| |
Collapse
|
31
|
Rauwers AW, Voor in ’t holt AF, Buijs JG, de Groot W, Hansen BE, Bruno MJ, Vos MC. High prevalence rate of digestive tract bacteria in duodenoscopes: a nationwide study. Gut 2018; 67:1637-1645. [PMID: 29636382 PMCID: PMC6109280 DOI: 10.1136/gutjnl-2017-315082] [Citation(s) in RCA: 91] [Impact Index Per Article: 15.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/17/2017] [Revised: 02/16/2018] [Accepted: 02/26/2018] [Indexed: 01/24/2023]
Abstract
OBJECTIVE Increasing numbers of outbreaks caused by contaminated duodenoscopes used for Endoscopic Retrograde Cholangiopancreatography (ERCP) procedures have been reported, some with fatal outcomes. We conducted a nationwide cross-sectional study to determine the prevalence of bacterial contamination of reprocessed duodenoscopes in The Netherlands. DESIGN All 73 Dutch ERCP centres were invited to sample ≥2 duodenoscopes using centrally distributed kits according to uniform sampling methods, explained by video instructions. Depending on duodenoscope type, four to six sites were sampled and centrally cultured. Contamination was defined as (1) any microorganism with ≥20 colony forming units (CFU)/20 mL (AM20) and (2) presence of microorganisms with gastrointestinal or oral origin, independent of CFU count (MGO). RESULTS Sixty-seven out of 73 centres (92%) sampled 745 sites of 155 duodenoscopes. Ten different duodenoscope types from three distinct manufacturers were sampled including 69 (46%) Olympus TJF-Q180V, 43 (29%) Olympus TJF-160VR, 11 (7%) Pentax ED34-i10T, 8 (5%) Pentax ED-3490TK and 5 (3%) Fujifilm ED-530XT8. Thirty-three (22%) duodenoscopes from 26 (39%) centres were contaminated (AM20). On 23 (15%) duodenoscopes MGO were detected, including Enterobacter cloacae, Escherichia coli, Klebsiella pneumonia and yeasts. For both definitions, contamination was not duodenoscope type dependent (p values: 0.20 and higher). CONCLUSION In 39% of all Dutch ERCP centres, at least one AM20-contaminated patient-ready duodenoscope was identified. Fifteen per cent of the duodenoscopes harboured MGO, indicating residual organic material of previous patients, that is, failing of disinfection. These results suggest that the present reprocessing and process control procedures are not adequate and safe.
Collapse
Affiliation(s)
- Arjan W Rauwers
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Anne F Voor in ’t holt
- Department of Medical Microbiology and Infectious diseases, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Jolanda G Buijs
- Staff Office Medical Devices, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Woutrinus de Groot
- Department of Medical Microbiology and Infectious diseases, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Bettina E Hansen
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Marco J Bruno
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Margreet C Vos
- Department of Medical Microbiology and Infectious diseases, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| |
Collapse
|
32
|
Talebi Bezmin Abadi A. Diagnosis of Helicobacter pylori Using Invasive and Noninvasive Approaches. J Pathog 2018; 2018:9064952. [PMID: 29951318 PMCID: PMC5987299 DOI: 10.1155/2018/9064952] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2018] [Accepted: 04/12/2018] [Indexed: 01/06/2023] Open
Abstract
Helicobacter pylori (H. pylori) as gram-negative and spiral microorganism is responsible for colonization in the gastric microniche for more than 50% of world population. Recent studies have shown a critical role of H. pylori in the development of peptic ulcers, gastric mucosa-associated lymphoid tissue (MALT) lymphoma, and gastric cancer. Over the past decade, there has been a sharp interest to use noninvasive tests in diagnosis of the H. pylori infection. During the years after discovery by Marshall and Warren, it has been frequently declared that the rapid urease test (RUT) is one of the cheapest and rapid diagnostic approaches used in detecting the infection. Although the specificity and sensitivity are durable for this test, clinical experiences had shown that the ideal results are only achieved only if we take biopsies from both corpus and antrum at the same time. Given the diagnosis of the H. pylori in clinical samples, gastroenterologists are facing a long list of various molecular and nonmolecular tests. We need more in-depth researches and investigations to correctly generalize rapid and accurate molecular tests determining both bacterial identity and antibiotic resistance profile.
Collapse
Affiliation(s)
- Amin Talebi Bezmin Abadi
- Department of Bacteriology, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
| |
Collapse
|
33
|
Physico-chemistry of bacterial transmission versus adhesion. Adv Colloid Interface Sci 2017; 250:15-24. [PMID: 29129313 DOI: 10.1016/j.cis.2017.11.002] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2017] [Revised: 11/02/2017] [Accepted: 11/03/2017] [Indexed: 12/11/2022]
Abstract
Bacterial adhesion is a main problem in many biomedical, domestic, natural and industrial environments and forms the onset of the formation of a biofilm, in which adhering bacteria grow into a multi-layered film while embedding themselves in a matrix of extracellular polymeric substances. It is usually assumed that bacterial adhesion occurs from air or by convective-diffusion from a liquid suspension, but often bacteria adhere by transmission from a bacterially contaminated donor to a receiver surface. Therewith bacterial transmission is mechanistically different from adhesion, as it involves bacterial detachment from a donor surface followed by adhesion to a receiver one. Transmission is further complicated when the donor surface is not covered with a single layer of adhering bacteria but with a multi-layered biofilm, in which case bacteria can be transmitted either by interfacial failure at the biofilm-donor surface or through cohesive failure in the biofilm. Transmission through cohesive failure in a biofilm is more common than interfacial failure. The aim of this review is to oppose surface thermodynamics and adhesion force analyses, as can both be applied towards bacterial adhesion, with their appropriate extensions towards transmission. Opposition of surface thermodynamics and adhesion force analyses, will allow to distinguish between transmission of bacteria from a donor covered with a (sub)monolayer of adhering bacteria or a multi-layered biofilm. Contact angle measurements required for surface thermodynamic analyses of transmission are of an entirely different nature than analyses of adhesion forces, usually measured through atomic force microscopy. Nevertheless, transmission probabilities based on Weibull analyses of adhesion forces between bacteria and donor and receiver surfaces, correspond with the surface thermodynamic preferences of bacteria for either the donor or receiver surface. Surfaces with low adhesion forces such as polymer-brush coated or nanostructured surfaces are thus preferable for use as non-adhesive receiver surfaces, but at the same time should be avoided for use as a donor surface. Since bacterial transmission occurs under a contact pressure between two surfaces, followed by their separation under tensile or shear pressure and ultimately detachment, this will affect biofilm structure. During the compression phase of transmission, biofilms are compacted into a more dense film. After transmission, and depending on the ability of the bacterial strain involved to produce extracellular polymeric substances, biofilm left-behind on a donor or transmitted to a receiver surface will relax to its original, pre-transmission structure owing to the viscoelasticity of the extracellular polymeric substances matrix, when present. Apart from mechanistic differences between bacterial adhesion and transmission, the low numbers of bacteria generally transmitted require careful selection of suitably sensitive enumeration methods, for which culturing and optical coherence tomography are suggested. Opposing adhesion and transmission as done in this review, not only yields a better understanding of bacterial transmission, but may stimulate researchers to more carefully consider whether an adhesion or transmission model is most appropriate in the specific area of application aimed for, rather than routinely relying on adhesion models.
Collapse
|
34
|
Abstract
Inadequate drying of endoscope channels is a possible cause of replication and survival of remaining pathogens during storage. The presence during storage of potentially contaminated water in endoscope channels may promote bacterial proliferation and biofilm formation. An incomplete drying procedure or lack of drying and not storing in a vertical position are the most usual problems identified during drying and endoscope storage. Inadequate drying and storage procedures, together with inadequate cleaning and disinfection, are the most important sources of endoscope contamination and post-endoscopic infection. Flexible endoscopes may be dried in automated endoscope reprocessors (AERs), manually, or in drying/storage cabinets. Flushing of the endoscope channels with 70-90% ethyl or isopropyl alcohol followed by forced air drying is recommended by several guidelines. Current guidelines recommend that flexible endoscopes are stored in a vertical position in a closed, ventilated cupboard. Drying and storage cabinets have a drying system that circulates and forces the dry filtered air through the endoscope channels. Endoscope reprocessing guidelines are inconsistent with one another or give no exact recommendations about drying and storage of flexible endoscopes. There is no conclusive evidence on the length of time endoscopes can be safely stored before requiring re-disinfection and before they pose a contamination risk. To minimize the risk of disease transmission and nosocomial infection, modification and revision of guidelines are recommended as required to be consistent with one another.
Collapse
Affiliation(s)
- J Kovaleva
- Centre for Medical Analysis, Herentals, Belgium.
| |
Collapse
|