1
|
Dobrynina EA, Zykova VA, Zhuravleva IY, Kuznetsova EV, Surovtsev NV. Brillouin spectroscopy of medically relevant samples of bovine jugular vein and pericardium. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2024; 321:124692. [PMID: 38908361 DOI: 10.1016/j.saa.2024.124692] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Revised: 06/07/2024] [Accepted: 06/18/2024] [Indexed: 06/24/2024]
Abstract
There is the rapid growth in application of Brillouin scattering spectroscopy to biomedical objects in order to characterize their mechanoelastic properties in this way. However, the possibilities and limitations of the method when applied to tissues have not yet been clarified. Here, applicability of Brillouin spectroscopy for testing the elastic response of medically relevant tissues of bovine jugular vein and pericardium was considered. Parameters of the Brillouin peak were studied for samples untreated, diepoxide-fixed, and preserved after treatment in alcohol solutions. It was found that diepoxide cross-linking resulted to a slight tendency to increase the Brillouin position for hydrated tissues. The variations in the position and width of the Brillouin peaks, associated with local fluctuations in water concentration, were reduced after diepoxide treatment in the case of the pericardium, but not in the case of the vein wall. To obtain more information about the elastic response of the protein scaffold without the participation of water, dried samples were also studied. Brillouin spectra of the dried pericardium and vein wall revealed a significant increase in the Brillouin peak position (elastic modulus) after conservation in alcohol. In the case of the vein wall, this effect was found for both collagen and elastin-related peaks, which were identified in the Brillouin spectrum. This result corresponds to a denser packing of fibrous proteins after preservation in alcohol solutions. The ability of Brillouin spectroscopy to independently characterize the effect of treatment on the instantaneous elastic modulus of various tissue components is also attractive for its application in the development of new materials for bioimplants. A comparison of the Brillouin longitudinal and Young's elastic moduli determined for the hydrated samples of the vein and pericardium showed that there is no clear correspondence between these material parameters. The usefulness of using both experimental methods to obtain new information about the elastic response of the material is discussed.
Collapse
Affiliation(s)
- E A Dobrynina
- Institute of Automation and Electrometry, Russian Academy of Sciences, Novosibirsk 630090, Russia
| | - V A Zykova
- Institute of Automation and Electrometry, Russian Academy of Sciences, Novosibirsk 630090, Russia
| | - I Yu Zhuravleva
- E. Meshalkin National Medical Research Center of the RF Ministry of Health, Novosibirsk 630055, Russia
| | - E V Kuznetsova
- E. Meshalkin National Medical Research Center of the RF Ministry of Health, Novosibirsk 630055, Russia
| | - N V Surovtsev
- Institute of Automation and Electrometry, Russian Academy of Sciences, Novosibirsk 630090, Russia.
| |
Collapse
|
2
|
Deymier AC, Deymier PA. Open-system force-elongation relationship of collagen in chemo-mechanical equilibrium with water. J Mech Behav Biomed Mater 2024; 152:106464. [PMID: 38367533 DOI: 10.1016/j.jmbbm.2024.106464] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Revised: 02/07/2024] [Accepted: 02/13/2024] [Indexed: 02/19/2024]
Abstract
A significant deformation mechanism of collagen at low loads is molecular uncoiling and rearrangement. Although the effect of hydration and cross-linking has been investigated at larger loads when collagen undergoes molecular sliding, their effects on collagen molecular reorganization remain unclear. Here we develop two thermodynamic models that use the notion of open-system elasticity to elucidate the effect of swelling due to water uptake during deformation of collagen networks under low and high cross-linking conditions. With low crosslinking, entropic contributions dominate resulting in rejection of solvent from the polymer network leading to reduced collagen stiffness with increased loads. Contrarily, high cross-linking inhibits initial coiling and structural kinking and the mechanical behavior is dominated by elastic energy. In this configuration, the solvent content depends on the sign of the applied load resulting in a non-linear open-system stress-strain relationship. The models provide insight on the parameters that impact the stress-strain relationships of hydrated collagen and can inform the way collagenous matrices are treated both in medical and laboratory settings.
Collapse
Affiliation(s)
- A C Deymier
- Department of Biomedical Engineering, UConn Health, Farmington, CT, USA.
| | - P A Deymier
- Department of Materials Science and Engineering, University of Arizona, Tucson, AZ, 85721, USA
| |
Collapse
|
3
|
Magerle R, Zech P, Dehnert M, Bendixen A, Otto A. Rate-independent hysteretic energy dissipation in collagen fibrils. SOFT MATTER 2024; 20:2831-2839. [PMID: 38456340 DOI: 10.1039/d3sm01625k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/09/2024]
Abstract
Nanoindentation cycles measured with an atomic force microscope on hydrated collagen fibrils exhibit a rate-independent hysteresis with return point memory. This previously unknown energy dissipation mechanism describes in unified form elastoplastic indentation, capillary adhesion, and surface leveling at indentation velocities smaller than 1 μm s-1, where viscous friction is negligible. A generic hysteresis model, based on force-distance data measured during one large approach-retract cycle, predicts the force (output) and the dissipated energy for arbitrary indentation trajectories (input). While both quantities are rate independent, they do depend nonlinearly on indentation history and on indentation amplitude.
Collapse
Affiliation(s)
- Robert Magerle
- Fakultät für Naturwissenschaften, Technische Universität Chemnitz, 09107 Chemnitz, Germany.
| | - Paul Zech
- Fakultät für Naturwissenschaften, Technische Universität Chemnitz, 09107 Chemnitz, Germany.
| | - Martin Dehnert
- Fakultät für Naturwissenschaften, Technische Universität Chemnitz, 09107 Chemnitz, Germany.
| | - Alexandra Bendixen
- Fakultät für Naturwissenschaften, Technische Universität Chemnitz, 09107 Chemnitz, Germany.
| | - Andreas Otto
- Fakultät für Naturwissenschaften, Technische Universität Chemnitz, 09107 Chemnitz, Germany.
| |
Collapse
|
4
|
Kim E, Song D, Park D, Kim H, Shin G. Effect of smartphone use on cervical spine stability. J Biomech 2024; 166:112053. [PMID: 38513400 DOI: 10.1016/j.jbiomech.2024.112053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 03/13/2024] [Accepted: 03/17/2024] [Indexed: 03/23/2024]
Abstract
Using a smartphone often involves a sustained head-forward tilt posture, which may deteriorate the mechanism of muscle reaction efficiency or reduce the stiffness of connective tissues of the cervical spine. These changes in muscular and connective tissues can impair cervical spine stability and contribute to developing neck pain symptoms. In this experiment, change in the cervical spine stability associated with a sustained smartphone use posture was evaluated by quantifying the effective stiffness and the reflexive responses of the head to sudden perturbations. Seventeen young smartphone users maintained their heads tilted forward approximately 30° for 30 min while watching videos on their smartphones in sitting. Data show that the measures of cervical spine stability did not change significantly after the smartphone use task despite developing mild to moderate neck and upper body discomfort symptoms. Study findings imply that keeping the head tilt posture for 30 min for smartphone use did not significantly alter spinal stability, rejecting its association with neck discomfort.
Collapse
Affiliation(s)
- Eunjee Kim
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology, Ulsan, Republic of Korea.
| | - Donghyun Song
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology, Ulsan, Republic of Korea
| | - Dasom Park
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology, Ulsan, Republic of Korea
| | - Hyorim Kim
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology, Ulsan, Republic of Korea
| | - Gwanseob Shin
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology, Ulsan, Republic of Korea
| |
Collapse
|
5
|
Barrett JM, Callaghan JP. Strain inhibition of bacterial collagenase is consistent with a collagen fibril uncrimping mechanism in rat tail tendons. J Biomech 2024; 162:111892. [PMID: 38061208 DOI: 10.1016/j.jbiomech.2023.111892] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Revised: 11/23/2023] [Accepted: 11/28/2023] [Indexed: 01/16/2024]
Abstract
Mechanical strain inhibits bacterial collagenase from cleaving collagen. Additionally, the toe region of a soft tissue's force-elongation curve arises from sequentially engaging collagen fibrils as the tissue lengthens. Together, these phenomena suggest that mechanical strain may gradually inhibit collagenase activity through a soft tissue's toe region. Therefore, this investigation sought to test this hypothesis. 92 rat tail tendon fascicles from 3 female sentinel animals underwent preliminary stiffness tests, and their force-elongation curves were fit to a collagen distribution model. This distribution-based model calculated the force magnitude corresponding to p% of collagen fibril engagement. Specimens were separated into one of five levels of p, and that level of force was maintained for two hours while being exposed to 0.054 U/mL of bacterial collagenase from C. histolyticum. The specimens were strained to failure following the creep test, and the relative reduction in stiffness was quantified to estimate the fraction of digested fibrils. Every 10% additional collagen engagement corresponded to a 6.3% (97% highest density interval: 4.3 - 8.4%) retention of stiffness, which indicated collagenase inhibition. The results of this investigation were consistent with a strain-inhibition hypothesis along with the established uncrimping mechanism in the toe region. These results support an interaction between mechanical strain and collagenolysis, which may be valuable for disease prevention or treatment.
Collapse
Affiliation(s)
- Jeff M Barrett
- Department of Kinesiology and Health Sciences, University of Waterloo, Canada.
| | - Jack P Callaghan
- Department of Kinesiology and Health Sciences, University of Waterloo, Canada.
| |
Collapse
|
6
|
Batool S, Roth BJ, Xia Y. Depth-Dependent Strain Model (1D) for Anisotropic Fibrils in Articular Cartilage. MATERIALS (BASEL, SWITZERLAND) 2024; 17:238. [PMID: 38204091 PMCID: PMC10779946 DOI: 10.3390/ma17010238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2023] [Revised: 12/21/2023] [Accepted: 12/29/2023] [Indexed: 01/12/2024]
Abstract
The mechanical response of articular cartilage (AC) under compression is anisotropic and depth-dependent. AC is osmotically active, and its intrinsic osmotic swelling pressure is balanced by its collagen fibril network. This mechanism requires the collagen fibers to be under a state of tensile pre-strain. A simple mathematical model is used to explain the depth-dependent strain calculations observed in articular cartilage under 1D axial compression (perpendicular to the articular surface). The collagen fibers are under pre-strain, influenced by proteoglycan concentration (fixed charged density, FCD) and collagen stiffness against swelling stress. The stiffness is introduced in our model as an anisotropic modulus that varies with fibril orientation through tissue depth. The collagen fibers are stiffer to stretching parallel to their length than perpendicular to it; when combined with depth-varying FCD, the model successfully predicts how tissue strains decrease with depth during compression. In summary, this model highlights that the mechanical properties of cartilage depend not only on proteoglycan concentration but also on the intrinsic properties of the pre-strained collagen network. These properties are essential for the proper functioning of articular cartilage.
Collapse
Affiliation(s)
| | - Bradley J. Roth
- Department of Physics, Oakland University, Rochester, MI 48309, USA; (S.B.); (Y.X.)
| | | |
Collapse
|
7
|
Ristaniemi A, Šećerović A, Grad S, Ferguson SJ. A Novel Fiber-Reinforced Poroviscoelastic Bovine Intervertebral Disc Finite Element Model for Organ Culture Experiment Simulations. J Biomech Eng 2023; 145:121006. [PMID: 37773639 DOI: 10.1115/1.4063557] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2023] [Accepted: 08/28/2023] [Indexed: 10/01/2023]
Abstract
Intervertebral disc (IVD) degeneration and methods for repair and regeneration have commonly been studied in organ cultures with animal IVDs under compressive loading. With the recent establishment of a novel multi-axial organ culture system, accurate predictions of the global and local mechanical response of the IVD are needed for control system development and to aid in experiment planning. This study aimed to establish a finite element model of bovine IVD capable of predicting IVD behavior at physiological and detrimental load levels. A finite element model was created based on the dimensions and shape of a typical bovine IVD used in the organ culture. The nucleus pulposus (NP) was modeled as a neo-Hookean poroelastic material and the annulus fibrosus (AF) as a fiber-reinforced poroviscoelastic material. The AF consisted of 10 lamella layers and the material properties were distributed in the radial direction. The model outcome was compared to a bovine IVD in a compressive stress-relaxation experiment. A parametric study was conducted to investigate the effect of different material parameters on the overall IVD response. The model was able to capture the equilibrium response and the relaxation response at physiological and higher strain levels. Permeability and elastic stiffness of the AF fiber network affected the overall response most prominently. The established model can be used to evaluate the response of the bovine IVD at strain levels typical for organ culture experiments, to define relevant boundaries for such studies, and to aid in the development and use of new multi-axial organ culture systems.
Collapse
Affiliation(s)
- Aapo Ristaniemi
- AO Research Institute Davos, Clavadelerstrasse 8, Davos 7270, Switzerland
| | - Amra Šećerović
- AO Research Institute Davos, Clavadelerstrasse 8, Davos 7270, Switzerland
| | - Sibylle Grad
- AO Research Institute Davos, Clavadelerstrasse 8, Davos 7270, Switzerland
| | - Stephen J Ferguson
- Institute for Biomechanics, ETH Zürich, Hönggerbergring 64, Zürich 8093, Switzerland
| |
Collapse
|
8
|
Nie Y, Gao H, Ji H. The energy dissipation property in bioinspired staggered composites with the viscoelastic matrix. J Mech Behav Biomed Mater 2023; 146:106068. [PMID: 37639934 DOI: 10.1016/j.jmbbm.2023.106068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2023] [Revised: 08/01/2023] [Accepted: 08/03/2023] [Indexed: 08/31/2023]
Abstract
Many biological materials, such as bone and nacre, exhibit remarkable combinations of stiffness, strength, toughness, and impact resistance over millions of years of evolution. They provide prototypes for designing high-performance artificial composites. However, the dynamic properties of biological materials under impact loading are still not clear. In this study, we establish a dynamic shear-lag model to explore the dynamic response and the energy dissipation capacity of bioinspired staggered composites with a viscoelastic matrix under impact loading. The time domain solution of the dynamic shear-lag model is derived. Then, the model is verified by comparing it with the results from the finite element method. The results demonstrate that matrix viscosity plays a significant role in dissipating the impact energy and enhances the wave transformation between adjacent tablets. Furthermore, there exists an optimal viscosity coefficient to achieve an excellent balance between the rate and efficiency of energy dissipation. The model and the results can not only reveal the energy dissipation property of biological materials but also provide guidelines for the design and optimization of high-performance composites.
Collapse
Affiliation(s)
- Yunqing Nie
- College of Aerospace Science and Engineering, National University of Defense Technology, 109 Deya Road, Changsha, 410073, Hunan, People's Republic of China
| | - Hua Gao
- Northwest Institute of Mechanical and Electrical Engineering, 5 BiYuan Road, Xianyang, 712099, Shanxi, People's Republic of China
| | - Haoran Ji
- Intelligent Game and Decision Lab, Haidian District, 100071, Beijing, People's Republic of China.
| |
Collapse
|
9
|
Handelshauser M, Chiang YR, Marchetti-Deschmann M, Thurner PJ, Andriotis OG. Collagen fibril tensile response described by a nonlinear Maxwell model. J Mech Behav Biomed Mater 2023; 145:105991. [PMID: 37480709 DOI: 10.1016/j.jmbbm.2023.105991] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 06/20/2023] [Accepted: 06/23/2023] [Indexed: 07/24/2023]
Abstract
Collagen fibrils are the basic structural building blocks that provide mechanical properties such as stiffness, toughness, and strength to tissues from the nano- to the macroscale. Collagen fibrils are highly hydrated and transient deformation mechanisms contribute to their mechanical behavior. One approach to describe and quantify the apparent viscoelastic behavior of collagen fibrils is to find rheological models and fit the resulting empirical equations to experimental data. In this study, we consider a nonlinear rheological Maxwell model for this purpose. The model was fitted to tensile stress-time data from experiments conducted in a previous study on hydrated and partially dehydrated individual collagen fibrils via AFM. The derivative tensile modulus, estimated from the empirical equation, increased for decreasing hydration of the collagen fibril. The viscosity is only marginally affected by hydration but shows a dependency with strain rate, suggesting thixotropic behavior for low strain rates.
Collapse
Affiliation(s)
- Martin Handelshauser
- Institute of Lightweight Design and Structural Biomechanics, TU Wien, 1060, Vienna, Austria; Institute of Chemical Technologies and Analytics, TU Wien, 1060, Vienna, Austria
| | - You-Rong Chiang
- Institute of Lightweight Design and Structural Biomechanics, TU Wien, 1060, Vienna, Austria
| | | | - Philipp J Thurner
- Institute of Lightweight Design and Structural Biomechanics, TU Wien, 1060, Vienna, Austria
| | - Orestis G Andriotis
- Institute of Lightweight Design and Structural Biomechanics, TU Wien, 1060, Vienna, Austria.
| |
Collapse
|
10
|
Tsingos E, Bakker BH, Keijzer KAE, Hupkes HJ, Merks RMH. Hybrid cellular Potts and bead-spring modeling of cells in fibrous extracellular matrix. Biophys J 2023; 122:2609-2622. [PMID: 37183398 PMCID: PMC10397577 DOI: 10.1016/j.bpj.2023.05.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2022] [Revised: 02/17/2023] [Accepted: 05/10/2023] [Indexed: 05/16/2023] Open
Abstract
The mechanical interaction between cells and the extracellular matrix (ECM) is fundamental to coordinate collective cell behavior in tissues. Relating individual cell-level mechanics to tissue-scale collective behavior is a challenge that cell-based models such as the cellular Potts model (CPM) are well-positioned to address. These models generally represent the ECM with mean-field approaches, which assume substrate homogeneity. This assumption breaks down with fibrous ECM, which has nontrivial structure and mechanics. Here, we extend the CPM with a bead-spring model of ECM fiber networks modeled using molecular dynamics. We model a contractile cell pulling with discrete focal adhesion-like sites on the fiber network and demonstrate agreement with experimental spatiotemporal fiber densification and displacement. We show that at high network cross-linking, contractile cell forces propagate over at least eight cell diameters, decaying with distance with power law exponent n= 0.35 - 0.65 typical of viscoelastic ECMs. Further, we use in silico atomic force microscopy to measure local cell-induced network stiffening consistent with experiments. Our model lays the foundation for investigating how local and long-ranged cell-ECM mechanobiology contributes to multicellular morphogenesis.
Collapse
Affiliation(s)
- Erika Tsingos
- Mathematical Institute, Leiden University, Leiden, the Netherlands.
| | | | - Koen A E Keijzer
- Mathematical Institute, Leiden University, Leiden, the Netherlands
| | | | - Roeland M H Merks
- Mathematical Institute, Leiden University, Leiden, the Netherlands; Institute for Biology Leiden, Leiden University, Leiden, the Netherlands.
| |
Collapse
|
11
|
Lee KZ, Jeon J, Jiang B, Subramani SV, Li J, Zhang F. Protein-Based Hydrogels and Their Biomedical Applications. Molecules 2023; 28:4988. [PMID: 37446650 DOI: 10.3390/molecules28134988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Revised: 06/16/2023] [Accepted: 06/21/2023] [Indexed: 07/15/2023] Open
Abstract
Hydrogels made from proteins are attractive materials for diverse medical applications, as they are biocompatible, biodegradable, and amenable to chemical and biological modifications. Recent advances in protein engineering, synthetic biology, and material science have enabled the fine-tuning of protein sequences, hydrogel structures, and hydrogel mechanical properties, allowing for a broad range of biomedical applications using protein hydrogels. This article reviews recent progresses on protein hydrogels with special focus on those made of microbially produced proteins. We discuss different hydrogel formation strategies and their associated hydrogel properties. We also review various biomedical applications, categorized by the origin of protein sequences. Lastly, current challenges and future opportunities in engineering protein-based hydrogels are discussed. We hope this review will inspire new ideas in material innovation, leading to advanced protein hydrogels with desirable properties for a wide range of biomedical applications.
Collapse
Affiliation(s)
- Kok Zhi Lee
- Department of Energy, Environmental & Chemical Engineering, Washington University in St. Louis, One Brookings Drive, Saint Louis, MI 63130, USA
| | - Juya Jeon
- Department of Energy, Environmental & Chemical Engineering, Washington University in St. Louis, One Brookings Drive, Saint Louis, MI 63130, USA
| | - Bojing Jiang
- Department of Energy, Environmental & Chemical Engineering, Washington University in St. Louis, One Brookings Drive, Saint Louis, MI 63130, USA
| | - Shri Venkatesh Subramani
- Department of Energy, Environmental & Chemical Engineering, Washington University in St. Louis, One Brookings Drive, Saint Louis, MI 63130, USA
| | - Jingyao Li
- Department of Energy, Environmental & Chemical Engineering, Washington University in St. Louis, One Brookings Drive, Saint Louis, MI 63130, USA
| | - Fuzhong Zhang
- Department of Energy, Environmental & Chemical Engineering, Washington University in St. Louis, One Brookings Drive, Saint Louis, MI 63130, USA
- Institute of Materials Science and Engineering, Washington University in St. Louis, One Brookings Drive, Saint Louis, MI 63130, USA
- Division of Biological & Biomedical Sciences, Washington University in St. Louis, One Brookings Drive, Saint Louis, MI 63130, USA
| |
Collapse
|
12
|
Karimi A, Crouch DJ, Razaghi R, Crawford Downs J, Acott TS, Kelley MJ, Behnsen JG, Bosworth LA, Sheridan CM. Morphological and biomechanical analyses of the human healthy and glaucomatous aqueous outflow pathway: Imaging-to-modeling. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 236:107485. [PMID: 37149973 DOI: 10.1016/j.cmpb.2023.107485] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Revised: 03/09/2023] [Accepted: 03/13/2023] [Indexed: 05/09/2023]
Abstract
BACKGROUND AND OBJECTIVE Intraocular pressure (IOP) is maintained via a dynamic balance between the production of aqueous humor and its drainage through the trabecular meshwork (TM), juxtacanalicular connective tissue (JCT), and Schlemm's canal (SC) endothelium of the conventional outflow pathway. Primary open angle glaucoma (POAG) is often associated with IOP elevation that occurs due to an abnormally high outflow resistance across the outflow pathway. Outflow tissues are viscoelastic and actively interact with aqueous humor dynamics through a two-way fluid-structure interaction coupling. While glaucoma affects the morphology and stiffness of the outflow tissues, their biomechanics and hydrodynamics in glaucoma eyes remain largely unknown. This research aims to develop an image-to-model method allowing the biomechanics and hydrodynamics of the conventional aqueous outflow pathway to be studied. METHODS We used a combination of X-ray computed tomography and scanning electron microscopy to reconstruct high-fidelity, eye-specific, 3D microstructural finite element models of the healthy and glaucoma outflow tissues in cellularized and decellularized conditions. The viscoelastic TM/JCT/SC complex finite element models with embedded viscoelastic beam elements were subjected to a physiological IOP load boundary; the stresses/strains and the flow state were calculated using fluid-structure interaction and computational fluid dynamics. RESULTS Based on the resultant hydrodynamics parameters across the outflow pathway, the primary site of outflow resistance in healthy eyes was in the JCT and immediate vicinity of the SC inner wall, while the majority of the outflow resistance in the glaucoma eyes occurred in the TM. The TM and JCT in the glaucoma eyes showed 1.32-fold and 1.13-fold larger beam thickness and smaller trabecular space size (2.24-fold and 1.50-fold) compared to the healthy eyes. CONCLUSIONS Characterizing the accurate morphology of the outflow tissues may significantly contribute to constructing more accurate, robust, and reliable models, that can eventually help to better understand the dynamic IOP regulation, hydrodynamics of the aqueous humor, and outflow resistance dynamic in the human eyes. This model demonstrates proof of concept for determining changes to outflow resistance in healthy and glaucomatous tissues and thus may be utilized in larger cohorts of donor tissues where disease specificity, race, age, and gender of the eye donors may be accounted for.
Collapse
Affiliation(s)
- Alireza Karimi
- Department of Ophthalmology, Casey Eye Institute, Oregon Health & Science University, Portland, Oregon, United States
| | - Devon J Crouch
- Department of Eye and Vision Science, Institute of Life Course and Medical Sciences, Faculty of Health and Life Sciences, University of Liverpool, Liverpool L7 8TX, United Kingdom
| | - Reza Razaghi
- Department of Ophthalmology and Visual Sciences, University of Alabama at Birmingham, Birmingham, AL, United States
| | - J Crawford Downs
- Department of Ophthalmology and Visual Sciences, University of Alabama at Birmingham, Birmingham, AL, United States
| | - Ted S Acott
- Department of Ophthalmology, Casey Eye Institute, Oregon Health & Science University, Portland, Oregon, United States; Department of Biochemistry and Molecular Biology, Oregon Health & Science University, Portland, Oregon, United States
| | - Mary J Kelley
- Department of Ophthalmology, Casey Eye Institute, Oregon Health & Science University, Portland, Oregon, United States; Department of Integrative Biosciences, Oregon Health & Science University, Portland, Oregon, United States
| | - Julia G Behnsen
- Department of Mechanical, Materials, and Aerospace Engineering, University of Liverpool, Liverpool, L69 6GB, United Kingdom
| | - Lucy A Bosworth
- Department of Eye and Vision Science, Institute of Life Course and Medical Sciences, Faculty of Health and Life Sciences, University of Liverpool, Liverpool L7 8TX, United Kingdom
| | - Carl M Sheridan
- Department of Eye and Vision Science, Institute of Life Course and Medical Sciences, Faculty of Health and Life Sciences, University of Liverpool, Liverpool L7 8TX, United Kingdom.
| |
Collapse
|
13
|
Yang F, Das D, Karunakaran K, Genin GM, Thomopoulos S, Chasiotis I. Nonlinear time-dependent mechanical behavior of mammalian collagen fibrils. Acta Biomater 2023; 163:63-77. [PMID: 35259515 PMCID: PMC9441475 DOI: 10.1016/j.actbio.2022.03.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2021] [Revised: 02/16/2022] [Accepted: 03/02/2022] [Indexed: 11/01/2022]
Abstract
The viscoelastic mechanical behavior of collagenous tissues has been studied extensively at the macroscale, yet a thorough quantitative understanding of the time-dependent mechanics of the basic building blocks of tissues, the collagen fibrils, is still missing. In order to address this knowledge gap, stress relaxation and creep tests at various stress (5-35 MPa) and strain (5-20%) levels were performed with individual collagen fibrils (average diameter of fully hydrated fibrils: 253 ± 21 nm) in phosphate buffered saline (PBS). The experimental results showed that the time-dependent mechanical behavior of fully hydrated individual collagen fibrils reconstituted from Type I calf skin collagen, is described by strain-dependent stress relaxation and stress-dependent creep functions in both the heel-toe and the linear regimes of deformation in monotonic stress-strain curves. The adaptive quasilinear viscoelastic (QLV) model, originally developed to capture the nonlinear viscoelastic response of collagenous tissues, provided a very good description of the nonlinear stress relaxation and creep behavior of the collagen fibrils. On the other hand, the nonlinear superposition (NSP) model fitted well the creep but not the stress relaxation data. The time constants and rates extracted from the adaptive QLV and the NSP models, respectively, pointed to a faster rate for stress relaxation than creep. This nonlinear viscoelastic behavior of individual collagen fibrils agrees with prior studies of macroscale collagenous tissues, thus demonstrating consistent time-dependent behavior across length scales and tissue hierarchies. STATEMENT OF SIGNIFICANCE: Pure stress relaxation and creep experiments were conducted for the first time with fully hydrated individual collagen fibrils. It is shown that collagen nanofibrils have a nonlinear time-dependent behavior which agrees with prior studies on macroscale collagenous tissues, thus demonstrating consistent time-dependent behavior across length scales and tissue hierarchies. This new insight into the non-linear viscoelastic behavior of the building blocks of mammalian collagenous tissues may serve as the foundation for improved macroscale tissue models that capture the mechanical behavior across length scales.
Collapse
Affiliation(s)
- Fan Yang
- Aerospace Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Debashish Das
- Aerospace Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Kathiresan Karunakaran
- Aerospace Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Guy M Genin
- Mechanical Engineering and Materials Science, Washington University, St. Louis, MO 63130, USA
| | - Stavros Thomopoulos
- Orthopedic Surgery, Biomedical Engineering, Columbia University, New York, NY 10032, USA
| | - Ioannis Chasiotis
- Aerospace Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA.
| |
Collapse
|
14
|
Anderl WJ, Pearson N, Converse MI, Yu SM, Monson KL. Strain-induced collagen denaturation is rate dependent in failure of cerebral arteries. Acta Biomater 2023; 164:282-292. [PMID: 37116635 DOI: 10.1016/j.actbio.2023.04.032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Revised: 04/06/2023] [Accepted: 04/21/2023] [Indexed: 04/30/2023]
Abstract
While soft tissues are commonly damaged by mechanical loading, the manifestation of this damage at the microstructural level is not fully understood. Specifically, while rate-induced stiffening has been previously observed in cerebral arteries, associated changes in microstructural damage patterns following high-rate loading are largely undefined. In this study, we stretched porcine middle cerebral arteries to failure at 0.01 and >150 s-1, both axially and circumferentially, followed by probing for denatured tropocollagen using collagen hybridizing peptide (CHP). We found that collagen fibrils aligned with the loading direction experienced less denaturation following failure tests at high than low rates. Others have demonstrated similar rate dependence in tropocollagen denaturation during soft tissue failure, but this is the first study to quantify this behavior using CHP and to report it for cerebral arteries. These findings may have significant implications for traumatic brain injury and intracranial balloon angioplasty. We additionally observed possible tropocollagen denaturation in vessel layers primarily composed of fibrils transversely aligned to the loading axis. To our knowledge, this is the first observation of collagen denaturation due to transverse loading, but further research is needed to confirm this finding. STATEMENT OF SIGNIFICANCE: Previous work shows that collagen hybridizing peptide (CHP) can be used to identify collagen molecule unfolding and denaturation in mechanically overloaded soft tissues, including the cerebral arteries. But experiments have not explored collagen damage at rates relevant to traumatic brain injury. In this work, we quantified collagen damage in cerebral arteries stretched to failure at both high and low rates. We found that the collagen molecule is less damaged at high than at low rates, suggesting that damage mechanisms of either the collagen molecule or other elements of the collagen superstructure are rate dependent. This work implies that arteries failed at high rates, such as in traumatic brain injury, will have different molecular-level damage patterns than arteries failed at low rates. Consequently, improved understanding of damage characteristics may be expanded in the future to better inform clinically relevant cases of collagen damage such as angioplasty and injury healing.
Collapse
Affiliation(s)
| | - Noah Pearson
- DepSSSartment of Mechanical Engineering, University of Utah
| | | | - S Michael Yu
- Department of Biomedical Engineering, University of Utah; Department of Molecular Pharmaceutics, University of Utah
| | - Kenneth L Monson
- DepSSSartment of Mechanical Engineering, University of Utah; Department of Biomedical Engineering, University of Utah.
| |
Collapse
|
15
|
Al-Qudsy L, Hu YW, Xu H, Yang PF. Mineralized Collagen Fibrils: An Essential Component in Determining the Mechanical Behavior of Cortical Bone. ACS Biomater Sci Eng 2023; 9:2203-2219. [PMID: 37075172 DOI: 10.1021/acsbiomaterials.2c01377] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/21/2023]
Abstract
Bone comprises mechanically different materials in a specific hierarchical structure. Mineralized collagen fibrils (MCFs), represented by tropocollagen molecules and hydroxyapatite nanocrystals, are the fundamental unit of bone. The mechanical characterization of MCFs provides the unique adaptive mechanical competence to bone to withstand mechanical load. The structural and mechanical role of MCFs is critical in the deformation mechanisms of bone and the marvelous strength and toughness possessed by bone. However, the role of MCFs in the mechanical behavior of bone across multiple length scales is not fully understood. In the present study, we shed light upon the latest progress regarding bone deformation at multiple hierarchical levels and emphasize the role of MCFs during bone deformation. We propose the concept of hierarchical deformation of bone to describe the interconnected deformation process across multiple length scales of bone under mechanical loading. Furthermore, how the deterioration of bone caused by aging and diseases impairs the hierarchical deformation process of the cortical bone is discussed. The present work expects to provide insights on the characterization of MCFs in the mechanical properties of bone and lays the framework for the understanding of the multiscale deformation mechanics of bone.
Collapse
Affiliation(s)
- Luban Al-Qudsy
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an 710072, China
- Department of Medical Instrumentation Engineering Techniques, Electrical Engineering Technical College, Middle Technical University, 8998+QHJ Baghdad, Iraq
| | - Yi-Wei Hu
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an 710072, China
| | - Huiyun Xu
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an 710072, China
| | - Peng-Fei Yang
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an 710072, China
| |
Collapse
|
16
|
González-González MA, Alemansour H, Maroufi M, Coskun MB, Lloyd D, Reza Moheimani SO, Romero-Ortega MI. Biomechanics Characterization of Autonomic and Somatic Nerves by High Dynamic Closed-Loop MEMS force sensing. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.04.13.536752. [PMID: 37090537 PMCID: PMC10120675 DOI: 10.1101/2023.04.13.536752] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/25/2023]
Abstract
The biomechanics of peripheral nerves are determined by the blood-nerve barrier (BNB), together with the epineural barrier, extracellular matrix, and axonal composition, which maintain structural and functional stability. These elements are often ignored in the fabrication of penetrating devices, and the implant process is traumatic due to the mechanical distress, compromising the function of neuroprosthesis for sensory-motor restoration in amputees. Miniaturization of penetrating interfaces offers the unique opportunity of decoding individual nerve fibers associated to specific functions, however, a main issue for their implant is the lack of high-precision standardization of insertion forces. Current automatized electromechanical force sensors are available; however, their sensitivity and range amplitude are limited (i.e. mN), and have been tested only in-vitro. We previously developed a high-precision bi-directional micro-electromechanical force sensor, with a closed-loop mechanism (MEMS-CLFS), that while measuring with high-precision (-211.7μN to 211.5μN with a resolution of 4.74nN), can be used in alive animal. Our technology has an on-chip electrothermal displacement sensor with a shuttle beam displacement amplification mechanism, for large range and high-frequency resolution (dynamic range of 92.9 dB), which eliminates the adverse effect of flexural nonlinearity measurements, observed with other systems, and reduces the mechanical impact on delicate biological tissue. In this work, we use the MEMS-CLFS for in-vivo bidirectional measurement of biomechanics in somatic and autonomic nerves. Furthermore we define the mechanical implications of irrigation and collagen VI in the BNB, which is different for both autonomic and somatic nerves (~ 8.5-8.6 fold density of collagen VI and vasculature CD31+ in the VN vs ScN). This study allowed us to create a mathematical approach to predict insertion forces. Our data highlights the necessity of nerve-customization forces to prevent injury when implanting interfaces, and describes a high precision MEMS technology and mathematical model for their measurements.
Collapse
Affiliation(s)
| | - Hammed Alemansour
- Erik Jonsson School of Engineering and Computer Science, The University of Texas at Dallas, Richardson, TX. 75080
| | - Mohammad Maroufi
- Erik Jonsson School of Engineering and Computer Science, The University of Texas at Dallas, Richardson, TX. 75080
| | - Mustafa Bulut Coskun
- Erik Jonsson School of Engineering and Computer Science, The University of Texas at Dallas, Richardson, TX. 75080
| | - David Lloyd
- Biomedical Engineering and Biomedical Sciences. University of Houston, Houston TX. 77204-6064
| | - S. O. Reza Moheimani
- Erik Jonsson School of Engineering and Computer Science, The University of Texas at Dallas, Richardson, TX. 75080
| | - Mario I. Romero-Ortega
- Biomedical Engineering and Biomedical Sciences. University of Houston, Houston TX. 77204-6064
| |
Collapse
|
17
|
Atthapreyangkul A, Hoffman M, Pearce G, Standard O. Effect of geometrical structure variations on strength and damage onset of cortical bone using multi-scale cohesive zone based finite element method. J Mech Behav Biomed Mater 2023; 138:105578. [PMID: 36427415 DOI: 10.1016/j.jmbbm.2022.105578] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Accepted: 11/15/2022] [Indexed: 11/18/2022]
Abstract
Three-dimensional multi-scale finite element models were designed to examine the effects of geometrical structure variations on the damage onset in cortical bone at multiple structural scales. A cohesive zone finite element approach, together with anisotropic damage initiation criteria, is used to predict the onset of damage. The finite element models are developed to account for the onset of microdamage from the microscopic length scales consisting of collagen fibres, to the macroscopic level consisting of osteons and the Haversian canals. Numerical results indicated that the yield strain at the initiation of microcracks is independent of variations in the local mineral volume fraction at each structural scale. Further, the yield strain and strength properties of cortical bone are dependent on its structural anisotropy and hierarchical structure. A positive correlation is observed between bone strength and mineral content at each length scale.
Collapse
Affiliation(s)
| | - Mark Hoffman
- School of Materials Science and Engineering, UNSW, Sydney, NSW, 2052, Australia; School of Engineering, The University of Newcastle, NSW, 2308, Australia.
| | - Garth Pearce
- School of Mechanical and Manufacturing Engineering, UNSW, Sydney, NSW, 2052, Australia
| | - Owen Standard
- School of Materials Science and Engineering, UNSW, Sydney, NSW, 2052, Australia
| |
Collapse
|
18
|
Lin AH, Slater CA, Martinez CJ, Eppell SJ, Yu SM, Weiss JA. Collagen fibrils from both positional and energy-storing tendons exhibit increased amounts of denatured collagen when stretched beyond the yield point. Acta Biomater 2023; 155:461-470. [PMID: 36400348 PMCID: PMC9805521 DOI: 10.1016/j.actbio.2022.11.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2022] [Revised: 11/04/2022] [Accepted: 11/09/2022] [Indexed: 11/17/2022]
Abstract
Collagen molecules are the base structural unit of tendons, which become denatured during mechanical overload. We recently demonstrated that during tendon stretch, collagen denaturation occurs at the yield point of the stress-strain curve in both positional and energy-storing tendons. We were interested in investigating how this load is transferred throughout the collagen hierarchy, and sought to determine the onset of collagen denaturation when collagen fibrils are stretched. Fibrils are one level above the collagen molecule in the collagen hierarchy, allowing more direct probing of the effect of strain on collagen molecules. We isolated collagen fibrils from both positional and energy-storing tendon types and stretched them using a microelectromechanical system device to various levels of strain. We stained the fibrils with fluorescently labeled collagen hybridizing peptides that specifically bind to denatured collagen, and examined whether samples stretched beyond the yield point of the stress-strain curve exhibited increased amounts of denatured collagen. We found that collagen denaturation in collagen fibrils from both tendon types occurs at the yield point. Greater amounts of denatured collagen were found in post-yield positional fibrils than in energy-storing fibrils. This is despite a greater yield strain and yield stress in fibrils from energy-storing tendons compared to positional tendons. Interestingly, the peak modulus of collagen fibrils from both tendon types was the same. These results are likely explained by the greater crosslink density found in energy-storing tendons compared to positional tendons. The insights gained from this study could help management of tendon and other musculoskeletal injuries by targeting collagen molecular damage at the fibril level. STATEMENT OF SIGNIFICANCE: When tendons are stretched or torn, this can lead to collagen denaturation (damage). Depending on their biomechanical function, tendons are considered positional or energy-storing with different crosslink profiles. By stretching collagen fibrils instead of fascicles from both tendon types, we can more directly examine the effect of tensile stretch on the collagen molecule in tendons. We found that regardless of tendon type, collagen denaturation in fibrils occurs when they are stretched beyond the yield point of the stress-strain curve. This provides insight into how load affects different tendon sub-structures during tendon injuries and failure, which will help clinicians and researchers understand mechanisms of injuries and potentially target collagen molecular damage as a treatment strategy, leading to improved clinical outcomes following injury.
Collapse
Affiliation(s)
- Allen H Lin
- Department of Biomedical Engineering, University of Utah, United States; Scientific Computing and Imaging Institute, University of Utah, United States
| | - Christopher A Slater
- Department of Biomedical Engineering, Case Western Reserve University, United States
| | - Callie-Jo Martinez
- Department of Biomedical Engineering, University of Utah, United States; Scientific Computing and Imaging Institute, University of Utah, United States
| | - Steven J Eppell
- Department of Biomedical Engineering, Case Western Reserve University, United States
| | - S Michael Yu
- Department of Biomedical Engineering, University of Utah, United States; Department of Pharmaceutics and Pharmaceutical Chemistry, University of Utah, United States
| | - Jeffrey A Weiss
- Department of Biomedical Engineering, University of Utah, United States; Scientific Computing and Imaging Institute, University of Utah, United States; Department of Orthopaedics, University of Utah, United States.
| |
Collapse
|
19
|
Andriotis OG, Nalbach M, Thurner PJ. Mechanics of isolated individual collagen fibrils. Acta Biomater 2022; 163:35-49. [PMID: 36509398 DOI: 10.1016/j.actbio.2022.12.008] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 11/15/2022] [Accepted: 12/05/2022] [Indexed: 12/13/2022]
Abstract
Collagen fibrils are the fundamental structural elements in vertebrate animals and compose a framework that provides mechanical support to load-bearing tissues. Understanding how these fibrils initially form and mechanically function has been the focus of a myriad of detailed investigations over the last few decades. From these studies a great amount of knowledge has been acquired as well as a number of new questions to consider. In this review, we examine the current state of our knowledge of the mechanical properties of extant fibrils. We emphasize on the mechanical response and related deformation of collagen fibrils upon tension, which is the predominant load imposed in most collagen-rich tissues. We also illuminate the gaps in knowledge originating from the intriguing results that the field is still trying to interpret. STATEMENT OF SIGNIFICANCE: : Collagen is the result of millions of years of biological evolution and is a unique family of proteins, the majority of which provide mechanical support to biological tissues. Cells produce collagen molecules that self-assemble into larger structures, known as collagen fibrils. As simple as they appear under an optical microscope, collagen fibrils display a complex ultrastructural architecture tuned to the external forces that are imposed upon them. Even more complex is the way collagen fibrils deform under loading, and the nature of the mechanisms that drive their formation in the first place. Here, we present a cogent synthesis of the state-of-knowledge of collagen fibril mechanics. We focus on the information we have from in vitro experiments on individual, isolated from tissues, collagen fibrils and the knowledge available from in silico tests.
Collapse
Affiliation(s)
- Orestis G Andriotis
- Institute for Lightweight Design and Structural Biomechanics, TU Wien, Vienna, A-1060, Austria
| | - Mathis Nalbach
- Institute for Lightweight Design and Structural Biomechanics, TU Wien, Vienna, A-1060, Austria
| | - Philipp J Thurner
- Institute for Lightweight Design and Structural Biomechanics, TU Wien, Vienna, A-1060, Austria.
| |
Collapse
|
20
|
Brudnicki PAP, Gonsalves MA, Spinella SM, Kaufman LJ, Lu HH. Engineering collagenous analogs of connective tissue extracellular matrix. Front Bioeng Biotechnol 2022; 10:925838. [PMID: 36312546 PMCID: PMC9613959 DOI: 10.3389/fbioe.2022.925838] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2022] [Accepted: 07/07/2022] [Indexed: 11/17/2022] Open
Abstract
Connective tissue extracellular matrix (ECM) consists of an interwoven network of contiguous collagen fibers that regulate cell activity, direct biological function, and guide tissue homeostasis throughout life. Recently, ECM analogs have emerged as a unique ex vivo culture platform for studying healthy and diseased tissues and in the latter, enabling the screening for and development of therapeutic regimen. Since these tissue models can mitigate the concern that observations from animal models do not always translate clinically, the design and production of a collagenous ECM analogue with relevant chemistry and nano- to micro-scale architecture remains a frontier challenge in the field. Therefore, the objectives of this study are two-fold— first, to apply green electrospinning approaches to the fabrication of an ECM analog with nanoscale mimicry and second, to systematically optimize collagen crosslinking in order to produce a stable, collagen-like substrate with continuous fibrous architecture that supports human cell culture and phenotypic expression. Specifically, the “green” electrospinning solvent acetic acid was evaluated for biofabrication of gelatin-based meshes, followed by the optimization of glutaraldehyde (GTA) crosslinking under controlled ambient conditions. These efforts led to the production of a collagen-like mesh with nano- and micro-scale cues, fibrous continuity with little batch-to-batch variability, and proven stability in both dry and wet conditions. Moreover, the as-fabricated mesh architecture and native chemistry were preserved with augmented mechanical properties. These meshes supported the in vitro expansion of stem cells and the production of a mineralized matrix by human osteoblast-like cells. Collectively these findings demonstrate the potential of green fabrication in the production of a collagen-like ECM analog with physiological relevance. Future studies will explore the potential of this high-fidelity platform for elucidating cell-matrix interactions and their relevance in connective tissue healing.
Collapse
Affiliation(s)
- Philip A. P. Brudnicki
- Biomaterials and Interface Tissue Engineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, United States
| | - Matthew A. Gonsalves
- Biomaterials and Interface Tissue Engineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, United States
| | | | - Laura J. Kaufman
- Department of Chemistry, Columbia University, New York, NY, United States
| | - Helen H. Lu
- Biomaterials and Interface Tissue Engineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, United States
- *Correspondence: Helen H. Lu,
| |
Collapse
|
21
|
Karimi A, Razaghi R, Padilla S, Rahmati SM, Downs JC, Acott TS, Kelley MJ, Wang RK, Johnstone M. Viscoelastic Biomechanical Properties of the Conventional Aqueous Outflow Pathway Tissues in Healthy and Glaucoma Human Eyes. J Clin Med 2022; 11:6049. [PMID: 36294371 PMCID: PMC9605362 DOI: 10.3390/jcm11206049] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Revised: 10/11/2022] [Accepted: 10/12/2022] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND Although the tissues comprising the ocular conventional outflow pathway have shown strong viscoelastic mechanical response to aqueous humor pressure dynamics, the viscoelastic mechanical properties of the trabecular meshwork (TM), juxtacanalicular connective tissue (JCT), and Schlemm's canal (SC) inner wall are largely unknown. METHODS A quadrant of the anterior segment from two human donor eyes at low- and high-flow (LF and HF) outflow regions was pressurized and imaged using optical coherence tomography (OCT). A finite element (FE) model of the TM, the adjacent JCT, and the SC inner wall was constructed and viscoelastic beam elements were distributed in the extracellular matrix (ECM) of the TM and JCT to represent anisotropic collagen. An inverse FE-optimization algorithm was used to calculate the viscoelastic properties of the ECM/beam elements such that the TM/JCT/SC model and OCT imaging data best matched over time. RESULTS The ECM of the glaucoma tissues showed significantly larger time-dependent shear moduli compared to the heathy tissues. Significantly larger shear moduli were also observed in the LF regions of both the healthy and glaucoma eyes compared to the HF regions. CONCLUSIONS The outflow tissues in both glaucoma eyes and HF regions are stiffer and less able to respond to dynamic IOP.
Collapse
Affiliation(s)
- Alireza Karimi
- Department of Ophthalmology and Visual Sciences, University of Alabama at Birmingham, Birmingham, AL 35233, USA
| | - Reza Razaghi
- Department of Ophthalmology and Visual Sciences, University of Alabama at Birmingham, Birmingham, AL 35233, USA
| | - Steven Padilla
- Department of Ophthalmology, University of Washington, Seattle, WA 98109, USA
| | | | - J. Crawford Downs
- Department of Ophthalmology and Visual Sciences, University of Alabama at Birmingham, Birmingham, AL 35233, USA
| | - Ted S. Acott
- Departments of Ophthalmology and Biochemistry and Molecular Biology, Casey Eye Institute, Oregon Health & Science University, Portland, OR 97239, USA
| | - Mary J. Kelley
- Departments of Ophthalmology and Integrative Biosciences, Casey Eye Institute, Oregon Health & Science University, Portland, OR 97239, USA
| | - Ruikang K. Wang
- Department of Ophthalmology, University of Washington, Seattle, WA 98109, USA
- Department of Bioengineering, University of Washington, Seattle, WA 98105, USA
| | - Murray Johnstone
- Department of Ophthalmology, University of Washington, Seattle, WA 98109, USA
| |
Collapse
|
22
|
Moo EK, Ebrahimi M, Sibole SC, Tanska P, Korhonen RK. The intrinsic quality of proteoglycans, but not collagen fibres, degrades in osteoarthritic cartilage. Acta Biomater 2022; 153:178-189. [PMID: 36113721 DOI: 10.1016/j.actbio.2022.09.002] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Revised: 08/31/2022] [Accepted: 09/02/2022] [Indexed: 11/01/2022]
Abstract
The function of articular cartilage as a load-bearing connective tissue is derived primarily from a balanced interaction between the swelling proteoglycan (PG) matrix and tension-resistant collagen fibrous network. Such balance is compromised during joint disease such as osteoarthritis (OA) due to degradation to PGs and/or collagens. While the PG degradation is generally thought to be related to a loss of protein abundance, the collagenous degradation is more complex as it can be caused independently by a decrease of collagen content, disorganisation of fibrous structure and softening of individual collagen fibrils. A comprehensive understanding of the initial trajectories of degradation of PGs and collagen network can improve our chance of finding potential therapeutic solutions for OA. Here, we developed geometrically, structurally, and compositionally realistic and sample-specific Finite Element (FE) models under the framework of multiphasic mixture theory, from which the elastic moduli of collagen fibres and the PG load-bearing quality in healthy and diseased cartilages were estimated by numerical optimisation of the multi-step indentation stress relaxation force-time curves. We found the intrinsic quality of collagen fibres, measured by their elastic moduli, to stay constant for healthy and diseased cartilages. Combining with previous findings which show unaltered collagen content during early stages of OA, our results suggest the disorganisation of collagen fibrous network as the first form of collagenous degradation in osteoarthritic cartilage. We also found that PG degradation involves not only a loss of protein abundance, but also the quality of the remaining PGs in generating sufficient osmotic pressure for load bearing. This study sheds light on the mechanism of OA pathogenesis and highlights the restoration of collageneous organisation in cartilage as key medical intervention for OA. STATEMENT OF SIGNIFICANCE: Collagen network in articular cartilage consists of individual fibres that are organised into depth-dependent structure specialised for joint load-bearing and lubrication. During osteoarthritis, the collagen network undergoes mechanical degradation, but it is unclear if a loss of content, disorganisation of fibrous structure, or softening of individual fibres causes this degeneration. Using mechanical indentation, Finite Element modelling, and numerical optimisation methods, we determined that individual fibres did not soften in early disease stage. Together with previous findings showing unaltered collagen content, our results pinpoint the disorganisation of collagen structure as the main culprit for early collagenous degradation in osteoarthritic cartilage. Thus, early restoration in cartilage of collagen organisation, instead of individual fibre quality, may be key to slow osteoarthritis development.
Collapse
Affiliation(s)
- Eng Kuan Moo
- Department of Applied Physics, University of Eastern Finland, POB 1627, Kuopio 70211, Finland; Human Performance Laboratory, University of Calgary, 2500, University Drive NW, Calgary, Alberta 2N1N4, Canada.
| | | | - Scott C Sibole
- Human Performance Laboratory, University of Calgary, 2500, University Drive NW, Calgary, Alberta 2N1N4, Canada
| | - Petri Tanska
- Department of Applied Physics, University of Eastern Finland, POB 1627, Kuopio 70211, Finland
| | - Rami K Korhonen
- Department of Applied Physics, University of Eastern Finland, POB 1627, Kuopio 70211, Finland.
| |
Collapse
|
23
|
Shi L, Herrmann J, Bou Jawde S, Bates JHT, Nia HT, Suki B. Modeling the influence of gravity and the mechanical properties of elastin and collagen fibers on alveolar and lung pressure-volume curves. Sci Rep 2022; 12:12280. [PMID: 35853981 PMCID: PMC9294799 DOI: 10.1038/s41598-022-16650-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2022] [Accepted: 07/13/2022] [Indexed: 11/13/2022] Open
Abstract
The relationship between pressure (P) and volume (V) in the human lung has been extensively studied. However, the combined effects of gravity and the mechanical properties of elastin and collagen on alveolar and lung P–V curves during breathing are not well understood. Here, we extended a previously established thick-walled spherical model of a single alveolus with wavy collagen fibers during positive pressure inflation. First, we updated the model for negative pressure-driven inflation that allowed incorporation of a gravity-induced pleural pressure gradient to predict how the static alveolar P–V relations vary spatially throughout an upright human lung. Second, by introducing dynamic surface tension and collagen viscoelasticity, we computed the hysteresis loop of the lung P–V curve. The model was tested by comparing its predicted regional ventilation to literature data, which offered insight into the effects of microgravity on ventilation. The model has also produced novel testable predictions for future experiments about the variation of mechanical stresses in the septal walls and the contribution of collagen and elastin fibers to the P–V curve and throughout the lung. The model may help us better understand how mechanical stresses arising from breathing and pleural pressure variations affect regional cellular mechanotransduction in the lung.
Collapse
Affiliation(s)
- Linzheng Shi
- Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA, 02215, USA
| | - Jacob Herrmann
- Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA, 02215, USA
| | - Samer Bou Jawde
- Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA, 02215, USA
| | - Jason H T Bates
- Department of Medicine, University of Vermont, Burlington, VT, USA
| | - Hadi T Nia
- Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA, 02215, USA
| | - Béla Suki
- Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA, 02215, USA.
| |
Collapse
|
24
|
Fontenele FF, Bouklas N. Understanding the inelastic response of collagen fibrils: A viscoelastic-plastic constitutive model. Acta Biomater 2022; 163:78-90. [PMID: 35835288 DOI: 10.1016/j.actbio.2022.07.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 07/01/2022] [Accepted: 07/05/2022] [Indexed: 11/01/2022]
Abstract
Collagen fibrils, which are the lowest level fibrillar unit of organization of collagen, are thus of primary interest towards understanding the mechanical behavior of load-bearing soft tissues. The deformation of collagen fibrils shows unique mechanical features; namely, their high energy dissipation is even superior compared to most engineering materials. Additionally, there are indications that cyclic loading can further improve the toughness of collagen fibrils. Recent experiments from Liu at al. (2018) focused on the response of type I collagen fibrils to uniaxial cyclic loading, revealing some interesting results regarding their rate-dependent and inelastic response. In this work, we aim to develop a model that allows interpreting the complex nonlinear and inelastic response of collagen fibrils under cyclic loading. We propose a constitutive model that accounts for viscoelastic deformations through a decoupled strain-energy density function (into an elastic and a viscous parts), and for plastic deformations through plastic evolution laws. The stress-stretch response results obtained using this constitutive law showed good agreement with experimental data over complex loading paths. Ultimately we use the model to gain more insights on how cyclic loading and rate effects control the interplay between viscoelastic and plastic deformation in collagen fibrils, and to extrapolate the results from experimental data, analyzing how complex cyclic load influences energy dissipation and deformation mechanisms. STATEMENT OF SIGNIFICANCE: In this work, we develop a viscoelastic-plastic constitutive model for collagen fibrils with the aim of analyzing the effects of inelasticity and energy dissipation in this material, and more specifically the competition between viscoelasticity and plasticity in the context of cyclic loading and overload. Experimental and theoretical approaches so far have not fully clarified the interplay between viscous and plastic deformations during cyclic loading of collagen fibrils. Here, we aim to interpret the complex nonlinear response of collagen fibrils and, ultimately, suggest predictive capabilities that can inform tissue-level response and injury. To validate our model, we compare our results against the stress-stretch data obtained from experiments of cyclic loaded single fibrils performed by Liu et al. (2018).
Collapse
Affiliation(s)
- Fernanda F Fontenele
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, NY 14853, USA
| | - Nikolaos Bouklas
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, NY 14853, USA.
| |
Collapse
|
25
|
Song Y, Choi JH, Tumursukh NE, Kim NE, Jeon GY, Kim SE, Kim SI, Song JE, Elçin YM, Khang G. Macro- and microporous polycaprolactone/duck's feet collagen scaffold fabricated by combining facile phase separation and particulate leaching techniques to enhance osteogenesis for bone tissue engineering. JOURNAL OF BIOMATERIALS SCIENCE. POLYMER EDITION 2022; 33:1025-1042. [PMID: 35118913 DOI: 10.1080/09205063.2022.2036933] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Revised: 01/11/2022] [Accepted: 01/27/2022] [Indexed: 06/14/2023]
Abstract
Herein, a facile macro- and microporous polycaprolactone/duck's feet collagen scaffold (PCL/DC) was fabricated and characterized to confirm its applicability in bone tissue engineering. A biomimetic scaffold for bone tissue engineering and regeneration for bone defects is an important element. PCL is a widely applied biomaterial for bone tissue engineering due to its biocompatibility and biodegradability. However, the high hydrophobicity and low cell attachment site properties of PCL lead to an insufficient microenvironment in designing a scaffold. Collagen is a nature-derived biomaterial that is widely used in tissue engineering and has excellent biocompatibility, mechanical properties, and cell attachment moieties. Among the resources from which collagen can be obtained, DC contains a high amount of collagen type I (COL1), is biocompatible, and is cost-effective. In this study, the scaffolds were fabricated by blending DC with PCL in various ratios and applied non-solvent-induced phase separation (NIPS) and thermal-induced phase separation (TIPS) (N-TIPS), solvent casting and particulate leaching (SCPL), and gas foaming method to fabricate macro- and microporous structure. The characterization of the fabricated scaffolds was carried out by morphological analysis, bioactivity test, physicochemical analysis, and mechanical test. In vitro study was carried out by viability test, morphology observation, and gene expression. The results showed that the incorporation of DC enhances the physicochemical and mechanical properties of the scaffolds. Also, a large amount of bone mimetic apatite was formed according to the DC content in the bioactivity test. The in vitro study showed that the PCL/DC scaffold is biocompatible and the existence of apatite and DC formed a favorable microenvironment for cell proliferation and differentiation. Overall, the novel porous PCL/DC scaffold can be a promising biomaterial model for bone tissue engineering and regeneration.
Collapse
Affiliation(s)
- Youngeun Song
- Department of Bionanotechnology and Bio-Convergence Engineering, Jeonbuk National University, Jeonju-si, Jeonbuk, Korea
| | - Joo Hee Choi
- Department of Bionanotechnology and Bio-Convergence Engineering, Jeonbuk National University, Jeonju-si, Jeonbuk, Korea
| | - Nomin-Erdene Tumursukh
- Department of Bionanotechnology and Bio-Convergence Engineering, Jeonbuk National University, Jeonju-si, Jeonbuk, Korea
| | - Na Eun Kim
- Department of Bionanotechnology and Bio-Convergence Engineering, Jeonbuk National University, Jeonju-si, Jeonbuk, Korea
| | - Ga Young Jeon
- Department of Bionanotechnology and Bio-Convergence Engineering, Jeonbuk National University, Jeonju-si, Jeonbuk, Korea
| | - Se Eun Kim
- Department of Bionanotechnology and Bio-Convergence Engineering, Jeonbuk National University, Jeonju-si, Jeonbuk, Korea
| | - Soo In Kim
- Department of Bionanotechnology and Bio-Convergence Engineering, Jeonbuk National University, Jeonju-si, Jeonbuk, Korea
| | - Jeong Eun Song
- Department of Bionanotechnology and Bio-Convergence Engineering, Jeonbuk National University, Jeonju-si, Jeonbuk, Korea
| | - Yaşar Murat Elçin
- Tissue Engineering, Biomaterials and Nanobiotechnology Laboratory, Ankara University Faculty of Science, Ankara, Turkey
| | - Gilson Khang
- Department of Bionanotechnology and Bio-Convergence Engineering, Jeonbuk National University, Jeonju-si, Jeonbuk, Korea
- Department of PolymerNano Science & Technology and Polymer Materials Fusion Research Center, Jeonbuk National University, Jeonju-si, Jeonbuk, Korea
| |
Collapse
|
26
|
Bose S, Li S, Mele E, Silberschmidt VV. Exploring the Mechanical Properties and Performance of Type-I Collagen at Various Length Scales: A Progress Report. MATERIALS 2022; 15:ma15082753. [PMID: 35454443 PMCID: PMC9025246 DOI: 10.3390/ma15082753] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Revised: 04/04/2022] [Accepted: 04/06/2022] [Indexed: 12/30/2022]
Abstract
Collagen is the basic protein of animal tissues and has a complex hierarchical structure. It plays a crucial role in maintaining the mechanical and structural stability of biological tissues. Over the years, it has become a material of interest in the biomedical industries thanks to its excellent biocompatibility and biodegradability and low antigenicity. Despite its significance, the mechanical properties and performance of pure collagen have been never reviewed. In this work, the emphasis is on the mechanics of collagen at different hierarchical levels and its long-term mechanical performance. In addition, the effect of hydration, important for various applications, was considered throughout the study because of its dramatic influence on the mechanics of collagen. Furthermore, the discrepancies in reports of the mechanical properties of collagenous tissues (basically composed of 20-30% collagen fibres) and those of pure collagen are discussed.
Collapse
Affiliation(s)
- Shirsha Bose
- Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Loughborough LE11 3TU, Leicestershire, UK; (S.B.); (S.L.)
| | - Simin Li
- Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Loughborough LE11 3TU, Leicestershire, UK; (S.B.); (S.L.)
| | - Elisa Mele
- Department of Materials, Loughborough University, Loughborough LE11 3TU, Leicestershire, UK
- Correspondence: (E.M.); (V.V.S.)
| | - Vadim V. Silberschmidt
- Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Loughborough LE11 3TU, Leicestershire, UK; (S.B.); (S.L.)
- Laboratory of Mechanics of Biocompatible Materials and Devices, Perm National Research Polytechnic University, 614990 Perm, Russia
- Correspondence: (E.M.); (V.V.S.)
| |
Collapse
|
27
|
Bose S, Li S, Mele E, Silberschmidt VV. Fracture behaviour and toughening mechanisms of dry and wet collagen. Acta Biomater 2022; 142:174-184. [PMID: 35134565 DOI: 10.1016/j.actbio.2022.02.001] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2021] [Revised: 01/25/2022] [Accepted: 02/02/2022] [Indexed: 11/29/2022]
Abstract
The growing interest to the use of collagen films for biomedical applications motivates the analysis of their fracture behaviour in different environments. Studies revealed the decreased mechanical strength and stiffness as well as increased plasticity in water compared to collagen specimens tested in air. However, the fracture behaviour of pure collagen films in both air and water has not been reported so far. In this paper, the entire process of mode-I loading of single-edge notched tension (SENT) specimens was recorded and analysed. In case of in-air (dry) specimens, cracks propagated rapidly in a brittle fashion while large plastic deformations were observed in aqua prior to failure due to crack opening and a blunting mechanism in wet specimens. The fracture-toughness parameters for pure collagen in air and in aqua were estimated using linear-elastic (KI and GI) and elasto-plastic (JI) fracture-mechanics approaches, respectively, following the force-displacement response and deformational behaviour. GIC and JI were 1365 ± 112 J/m2 and 2500 ± 440 J/m2, respectively. Scanning electron microscopy was used to observe the structural changes linked to collagen fibrils in the crack-tip area and the fracture surface. For in-air specimens, the former mostly exhibited extrinsic toughening (usually at micro scale) acting behind the crack-tip, while in-aqua intrinsic toughening acting ahead of a crack tip was found. Fractography of in-air specimens showed no occurrence of voids while multiple micro-voids were found for in-aqua specimens. STATEMENT OF SIGNIFICANCE: The fracture toughness and crack propagation of both mineralised (bone, dentine) and non-mineralised (skin) tissues has been extensively investigated over the past decades. Though these tissues are rich in collagen, the fracture properties of pure collagen have not been quantified yet at macroscale. Considering the applications of collagen films in tissue regeneration, it is essential to perform investigations of their fracture behaviour in both dry and wet conditions. Determining the effect of environment on the fracture behaviour of collagen and understanding its toughening mechanism are essential for prevention of failures during application. Moreover, this would give an insight for fabrication of tougher collagen-based biomaterials for biomedical uses.
Collapse
Affiliation(s)
- Shirsha Bose
- Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Loughborough, Leicestershire LE11 3TU, UK
| | - Simin Li
- Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Loughborough, Leicestershire LE11 3TU, UK
| | - Elisa Mele
- Department of Materials, Loughborough University, Loughborough, Leicestershire LE113TU, UK
| | - Vadim V Silberschmidt
- Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Loughborough, Leicestershire LE11 3TU, UK; Laboratory of Mechanics of Biocompatible Materials and Devices, Perm National Research Polytechnic University, Perm 614990, Russia.
| |
Collapse
|
28
|
Atomic Force Microscopy Nanoindentation Method on Collagen Fibrils. MATERIALS 2022; 15:ma15072477. [PMID: 35407813 PMCID: PMC8999528 DOI: 10.3390/ma15072477] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/15/2022] [Revised: 03/20/2022] [Accepted: 03/24/2022] [Indexed: 12/24/2022]
Abstract
Atomic Force Microscopy nanoindentation method is a powerful technique that can be used for the nano-mechanical characterization of bio-samples. Significant scientific efforts have been performed during the last two decades to accurately determine the Young’s modulus of collagen fibrils at the nanoscale, as it has been proven that mechanical alterations of collagen are related to various pathological conditions. Different contact mechanics models have been proposed for processing the force–indentation data based on assumptions regarding the shape of the indenter and collagen fibrils and on the elastic or elastic–plastic contact assumption. However, the results reported in the literature do not always agree; for example, the Young’s modulus values for dry collagen fibrils expand from 0.9 to 11.5 GPa. The most significant parameters for the broad range of values are related to the heterogeneous structure of the fibrils, the water content within the fibrils, the data processing errors, and the uncertainties in the calibration of the probe. An extensive discussion regarding the models arising from contact mechanics and the results provided in the literature is presented, while new approaches with respect to future research are proposed.
Collapse
|
29
|
Yang F, Das D, Chasiotis I. Strain rate induced toughening of individual collagen fibrils. APPLIED PHYSICS LETTERS 2022; 120:114101. [PMID: 35355883 PMCID: PMC8934191 DOI: 10.1063/5.0084054] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/02/2022] [Accepted: 02/27/2022] [Indexed: 06/14/2023]
Abstract
The nonlinear mechanical behavior of individual nanoscale collagen fibrils is governed by molecular stretching and sliding that result in a viscous response, which is still not fully understood. Toward this goal, the in vitro mechanical behavior of individual reconstituted mammalian collagen fibrils was quantified in a broad range of strain-rates, spanning roughly six orders of magnitude, from 10-4 to 35 s-1. It is shown that the nonlinear mechanical response is strain rate sensitive with the tangent modulus in the linear deformation regime increasing monotonically from 214 ± 8 to 358 ± 11 MPa. More pronounced is the effect of the strain rate on the ultimate tensile strength that is found to increase monotonically by a factor of four, from 42 ± 6 to 160 ± 14 MPa. Importantly, fibril strengthening takes place without a reduction in ductility, which results in equivalently large increase in toughness with the increasing strain rate. This experimental strain rate dependent mechanical response is captured well by a structural constitutive model that incorporates the salient features of the collagen microstructure via a process of gradual recruitment of kinked tropocollagen molecules, thus giving rise to the initial "toe-heel" mechanical behavior, followed by molecular stretching and sustained intermolecular slip that is initiated at a strain rate dependent stress threshold. The model shows that the fraction of tropocollagen molecules undergoing straightening increases continuously during loading, whereas molecular sliding is initiated after a small fibril strain (1%-2%) and progressively increases with applied strain.
Collapse
|
30
|
Yang F, Das D, Chasiotis I. Microscale Creep and Stress Relaxation Experiments with Individual Collagen Fibrils. OPTICS AND LASERS IN ENGINEERING 2022; 150:106869. [PMID: 35027783 PMCID: PMC8752082 DOI: 10.1016/j.optlaseng.2021.106869] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Nanoscale macromolecular biological structures exhibit time-dependent behavior, yet a quantitative understanding of their time-dependent mechanical behavior remains elusive, largely due to experimental challenges in attaining sufficient spatial and temporal resolution and control of stress or strain in conditions that guarantee their molecular integrity. To address this gap, an experimental methodology was developed to conduct creep and stress relaxation experiments with individual mammalian collagen fibrils. An image-based edge detection method implemented with high magnification optical microscopy and combined with closed-loop proportional-integral-derivative (PID) control was implemented and calibrated to apply constant force or stretch ratio values to individual collagen fibrils via a Microelectromechanical Systems (MEMS) device. This experimental methodology allowed for real-time control of uniaxial tensile stress or strain with 27 nm displacement resolution. The overall experimental system was tuned to apply step inputs with rise times below 0.5 s, less than 2.5% overshoot, and steady-state error less than 0.5%. Three individual collagen fibrils with diameters 101-121 nm were subjected to creep and stress relaxation tests in the range 4-20% engineering strain, under partially hydrated conditions. The collagen fibrils demonstrated non-linear viscoelastic behavior that was described well by the adaptive quasi-linear viscoelastic model. The results of this study demonstrate for the first time that mammalian collagen fibrils, the building blocks of connective tissues, exhibit nonlinear viscoelastic behavior in their partially hydrated state.
Collapse
Affiliation(s)
- Fan Yang
- Aerospace Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | - Debashish Das
- Aerospace Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | - Ioannis Chasiotis
- Aerospace Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| |
Collapse
|
31
|
Aryeetey OJ, Frank M, Lorenz A, Estermann SJ, Reisinger AG, Pahr DH. A parameter reduced adaptive quasi-linear viscoelastic model for soft biological tissue in uniaxial tension. J Mech Behav Biomed Mater 2022; 126:104999. [PMID: 34999491 DOI: 10.1016/j.jmbbm.2021.104999] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 11/04/2021] [Accepted: 11/24/2021] [Indexed: 11/15/2022]
Abstract
Mechanical characterisation of soft viscous materials is essential for many applications including aerospace industries, material models for surgical simulation, and tissue mimicking materials for anatomical models. Constitutive material models are, therefore, necessary to describe soft biological tissues in physiologically relevant strain ranges. Hereby, the adaptive quasi-linear viscoelastic (AQLV) model enables accurate modelling of the strain-dependent non-linear viscoelastic behaviour of soft tissues with a high flexibility. However, the higher flexibility produces a large number of model parameters. In this study, porcine muscle and liver tissue samples were modelled in the framework of the originally published AQLV (3-layers of Maxwell elements) model using four incremental ramp-hold experiments in uniaxial tension. AQLV model parameters were reduced by decreasing model layers (M) as well as the number of experimental ramp-hold steps (N). Leave One out cross validation tests show that the original AQLV model (3M4N) with 19 parameters, accurately describes porcine muscle tissue with an average R2 of 0.90 and porcine liver tissue, R2 of 0.86. Reducing the number of layers (N) in the model produced acceptable model fits for 1-layer (R2 of 0.83) and 2-layer models (R2 of 0.89) for porcine muscle tissue and 1-layer (R2 of 0.84) and 2-layer model (R2 of 0.85) for porcine liver tissue. Additionally, a 2 step (2N) ramp-hold experiment was performed on additional samples of porcine muscle tissue only to further reduce model parameters. Calibrated spring constant values for 2N ramp-hold tests parameters k1 and k2 had a 16.8% and 38.0% deviation from those calibrated for a 4 step (4N) ramp hold experiment. This enables further reduction of material parameters by means of step reduction, effectively reducing the number of parameters required to calibrate the AQLV model from 19 for a 3M4N model to 8 for a 2M2N model, with the added advantage of reducing the time per experiment by 50%. This study proposes a 'reduced-parameter' AQLV model (2M2N) for the modelling of soft biological tissues at finite strain ranges. Sequentially, the comparison of model parameters of soft tissues is easier and the experimental burden is reduced.
Collapse
Affiliation(s)
- Othniel J Aryeetey
- TU Wien, Institute of Lightweight Design and Structural Biomechanics, Gumpendorfer Straße 7, 1060, Vienna, Austria; Karl Landsteiner University of Health Sciences, Department of Anatomy and Biomechanics, Division Biomechanics, Dr. Karl-Dorrek-Straße 30, 3500, Krems, Austria
| | - Martin Frank
- Karl Landsteiner University of Health Sciences, Department of Anatomy and Biomechanics, Division Biomechanics, Dr. Karl-Dorrek-Straße 30, 3500, Krems, Austria
| | - Andrea Lorenz
- Austrian Center for Medical Innovation & Technology (ACMIT), Viktor Kaplan-Straße 2/1, 2700, Wiener Neustadt, Austria
| | - Sarah-Jane Estermann
- TU Wien, Institute of Lightweight Design and Structural Biomechanics, Gumpendorfer Straße 7, 1060, Vienna, Austria; Karl Landsteiner University of Health Sciences, Department of Anatomy and Biomechanics, Division Biomechanics, Dr. Karl-Dorrek-Straße 30, 3500, Krems, Austria; Austrian Center for Medical Innovation & Technology (ACMIT), Viktor Kaplan-Straße 2/1, 2700, Wiener Neustadt, Austria
| | - Andreas G Reisinger
- TU Wien, Institute of Lightweight Design and Structural Biomechanics, Gumpendorfer Straße 7, 1060, Vienna, Austria; Karl Landsteiner University of Health Sciences, Department of Anatomy and Biomechanics, Division Biomechanics, Dr. Karl-Dorrek-Straße 30, 3500, Krems, Austria
| | - Dieter H Pahr
- TU Wien, Institute of Lightweight Design and Structural Biomechanics, Gumpendorfer Straße 7, 1060, Vienna, Austria; Karl Landsteiner University of Health Sciences, Department of Anatomy and Biomechanics, Division Biomechanics, Dr. Karl-Dorrek-Straße 30, 3500, Krems, Austria.
| |
Collapse
|
32
|
Golman M, Abraham AC, Kurtaliaj I, Marshall BP, Hu YJ, Schwartz AG, Guo XE, Birman V, Thurner PJ, Genin GM, Thomopoulos S. Toughening mechanisms for the attachment of architectured materials: The mechanics of the tendon enthesis. SCIENCE ADVANCES 2021; 7:eabi5584. [PMID: 34826240 PMCID: PMC8626067 DOI: 10.1126/sciadv.abi5584] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Accepted: 10/06/2021] [Indexed: 05/09/2023]
Abstract
Architectured materials offer tailored mechanical properties but are limited in engineering applications due to challenges in maintaining toughness across their attachments. The enthesis connects tendon and bone, two vastly different architectured materials, and exhibits toughness across a wide range of loadings. Understanding the mechanisms by which this is achieved could inform the development of engineered attachments. Integrating experiments, simulations, and previously unexplored imaging that enabled simultaneous observation of mineralized and unmineralized tissues, we identified putative mechanisms of enthesis toughening in a mouse model and then manipulated these mechanisms via in vivo control of mineralization and architecture. Imaging uncovered a fibrous architecture within the enthesis that controls trade-offs between strength and toughness. In vivo models of pathology revealed architectural adaptations that optimize these trade-offs through cross-scale mechanisms including nanoscale protein denaturation, milliscale load-sharing, and macroscale energy absorption. Results suggest strategies for optimizing architecture for tough bimaterial attachments in medicine and engineering.
Collapse
Affiliation(s)
- Mikhail Golman
- Department of Orthopedic Surgery, Columbia University, New York, NY 10032, USA
- Department of Biomedical Engineering, Columbia University, New York, NY 10027, USA
| | - Adam C. Abraham
- Department of Orthopedic Surgery, Columbia University, New York, NY 10032, USA
| | - Iden Kurtaliaj
- Department of Orthopedic Surgery, Columbia University, New York, NY 10032, USA
- Department of Biomedical Engineering, Columbia University, New York, NY 10027, USA
| | - Brittany P. Marshall
- Department of Orthopedic Surgery, Columbia University, New York, NY 10032, USA
- Department of Biomedical Engineering, Columbia University, New York, NY 10027, USA
| | - Yizhong Jenny Hu
- Department of Biomedical Engineering, Columbia University, New York, NY 10027, USA
| | - Andrea G. Schwartz
- NSF Science and Technology Center for Engineering Mechanobiology, Washington University, St. Louis, MO 63130, USA
| | - X. Edward Guo
- Department of Biomedical Engineering, Columbia University, New York, NY 10027, USA
| | - Victor Birman
- Missouri University of Science and Technology, Rolla, MO 65409, USA
| | - Philipp J. Thurner
- Institute of Lightweight Design and Structural Biomechanics, Vienna University of Technology, Vienna, Austria
| | - Guy M. Genin
- NSF Science and Technology Center for Engineering Mechanobiology, Washington University, St. Louis, MO 63130, USA
| | - Stavros Thomopoulos
- Department of Orthopedic Surgery, Columbia University, New York, NY 10032, USA
- Department of Biomedical Engineering, Columbia University, New York, NY 10027, USA
| |
Collapse
|
33
|
A Data-Driven Memory-Dependent Modeling Framework for Anomalous Rheology: Application to Urinary Bladder Tissue. FRACTAL AND FRACTIONAL 2021. [DOI: 10.3390/fractalfract5040223] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
We introduce a data-driven fractional modeling framework for complex materials, and particularly bio-tissues. From multi-step relaxation experiments of distinct anatomical locations of porcine urinary bladder, we identify an anomalous relaxation character, with two power-law-like behaviors for short/long long times, and nonlinearity for strains greater than 25%. The first component of our framework is an existence study, to determine admissible fractional viscoelastic models that qualitatively describe linear relaxation. After the linear viscoelastic model is selected, the second stage adds large-strain effects to the framework through a fractional quasi-linear viscoelastic approach for the nonlinear elastic response of the bio-tissue of interest. From single-step relaxation data of the urinary bladder, a fractional Maxwell model captures both short/long-term behaviors with two fractional orders, being the most suitable model for small strains at the first stage. For the second stage, multi-step relaxation data under large strains were employed to calibrate a four-parameter fractional quasi-linear viscoelastic model, that combines a Scott-Blair relaxation function and an exponential instantaneous stress response, to describe the elastin/collagen phases of bladder rheology. Our obtained results demonstrate that the employed fractional quasi-linear model, with a single fractional order in the range α = 0.25–0.30, is suitable for the porcine urinary bladder, producing errors below 2% without need for recalibration over subsequent applied strains. We conclude that fractional models are attractive tools to capture the bladder tissue behavior under small-to-large strains and multiple time scales, therefore being potential alternatives to describe multiple stages of bladder functionality.
Collapse
|
34
|
Nordsletten D, Capilnasiu A, Zhang W, Wittgenstein A, Hadjicharalambous M, Sommer G, Sinkus R, Holzapfel GA. A viscoelastic model for human myocardium. Acta Biomater 2021; 135:441-457. [PMID: 34487858 DOI: 10.1016/j.actbio.2021.08.036] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2021] [Revised: 08/22/2021] [Accepted: 08/24/2021] [Indexed: 01/06/2023]
Abstract
Understanding the biomechanics of the heart in health and disease plays an important role in the diagnosis and treatment of heart failure. The use of computational biomechanical models for therapy assessment is paving the way for personalized treatment, and relies on accurate constitutive equations mapping strain to stress. Current state-of-the art constitutive equations account for the nonlinear anisotropic stress-strain response of cardiac muscle using hyperelasticity theory. While providing a solid foundation for understanding the biomechanics of heart tissue, most current laws neglect viscoelastic phenomena observed experimentally. Utilizing experimental data from human myocardium and knowledge of the hierarchical structure of heart muscle, we present a fractional nonlinear anisotropic viscoelastic constitutive model. The model is shown to replicate biaxial stretch, triaxial cyclic shear and triaxial stress relaxation experiments (mean error ∼7.68%), showing improvements compared to its hyperelastic (mean error ∼24%) counterparts. Model sensitivity, fidelity and parameter uniqueness are demonstrated. The model is also compared to rate-dependent biaxial stretch as well as different modes of biaxial stretch, illustrating extensibility of the model to a range of loading phenomena. STATEMENT OF SIGNIFICANCE: The viscoelastic response of human heart tissues has yet to be integrated into common constitutive models describing cardiac mechanics. In this work, a fractional viscoelastic modeling approach is introduced based on the hierarchical structure of heart tissue. From these foundations, the current state-of-the-art biomechanical models of the heart muscle are transformed using fractional viscoelasticity, replicating passive muscle function across multiple experimental tests. Comparisons are drawn with current models to highlight the improvements of this approach and predictive responses show strong qualitative agreement with experimental data. The proposed model presents the first constitutive model aimed at capturing viscoelastic nonlinear response across multiple testing regimes, providing a platform for better understanding the biomechanics of myocardial tissue in health and disease.
Collapse
Affiliation(s)
- David Nordsletten
- Division of Biomedical Engineering and Imaging Sciences, Department of Biomedical Engineering, King's College London, UK; Departments of Biomedical Engineering and Cardiac Surgery, University of Michigan, North Campus Research Center, Building 20, 2800 Plymouth Rd, Ann Arbor 48109, MI, USA.
| | - Adela Capilnasiu
- Division of Biomedical Engineering and Imaging Sciences, Department of Biomedical Engineering, King's College London, UK
| | - Will Zhang
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, USA
| | - Anna Wittgenstein
- Division of Biomedical Engineering and Imaging Sciences, Department of Biomedical Engineering, King's College London, UK
| | | | - Gerhard Sommer
- Institute of Biomechanics, Graz University of Technology, Austria
| | - Ralph Sinkus
- Division of Biomedical Engineering and Imaging Sciences, Department of Biomedical Engineering, King's College London, UK; Inserm U1148, LVTS, University Paris Diderot, University Paris 13, Paris, France
| | - Gerhard A Holzapfel
- Institute of Biomechanics, Graz University of Technology, Austria; Department of Structural Engineering, Norwegian University of Science and Technology, Trondheim, Norway
| |
Collapse
|
35
|
Asgeirsson DO, Christiansen MG, Valentin T, Somm L, Mirkhani N, Nami AH, Hosseini V, Schuerle S. 3D magnetically controlled spatiotemporal probing and actuation of collagen networks from a single cell perspective. LAB ON A CHIP 2021; 21:3850-3862. [PMID: 34505607 PMCID: PMC8507888 DOI: 10.1039/d1lc00657f] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Accepted: 08/28/2021] [Indexed: 05/15/2023]
Abstract
Cells continuously sense and react to mechanical cues from their surrounding matrix, which consists of a fibrous network of biopolymers that influences their fate and behavior. Several powerful methods employing magnetic control have been developed to assess the micromechanical properties within extracellular matrix (ECM) models hosting cells. However, many of these are limited to in-plane sensing and actuation, which does not allow the matrix to be probed within its full 3D context. Moreover, little attention has been given to factors specific to the model ECM systems that can profoundly influence the cells contained there. Here we present methods to spatiotemporally probe and manipulate extracellular matrix networks at the scale relevant to cells using magnetic microprobes (μRods). Our techniques leverage 3D magnetic field generation, physical modeling, and image analysis to examine and apply mechanical stimuli to fibrous collagen matrices. We determined shear moduli ranging between hundreds of Pa to tens of kPa and modeled the effects of proximity to rigid surfaces and local fiber densification. We analyzed the spatial extent and dynamics of matrix deformation produced in response to magnetic torques on the order of 10 pNm, deflecting fibers over an area spanning tens of micrometers. Finally, we demonstrate 3D actuation and pose extraction of fluorescently labelled μRods.
Collapse
Affiliation(s)
- Daphne O Asgeirsson
- Responsive Biomedical Systems Laboratory, Department of Health Science and Technology, ETH Zurich, 8093 Zurich, Switzerland.
| | - Michael G Christiansen
- Responsive Biomedical Systems Laboratory, Department of Health Science and Technology, ETH Zurich, 8093 Zurich, Switzerland.
| | - Thomas Valentin
- Responsive Biomedical Systems Laboratory, Department of Health Science and Technology, ETH Zurich, 8093 Zurich, Switzerland.
| | - Luca Somm
- Responsive Biomedical Systems Laboratory, Department of Health Science and Technology, ETH Zurich, 8093 Zurich, Switzerland.
| | - Nima Mirkhani
- Responsive Biomedical Systems Laboratory, Department of Health Science and Technology, ETH Zurich, 8093 Zurich, Switzerland.
| | - Amin Hosseini Nami
- Department of Biotechnology, College of Science, University of Tehran, Tehran 1417614411, Iran
| | - Vahid Hosseini
- Department of Bioengineering, University of California, Los Angeles, CA 90095, USA
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA 90024, USA
| | - Simone Schuerle
- Responsive Biomedical Systems Laboratory, Department of Health Science and Technology, ETH Zurich, 8093 Zurich, Switzerland.
| |
Collapse
|
36
|
Xu Q, Torres JE, Hakim M, Babiak PM, Pal P, Battistoni CM, Nguyen M, Panitch A, Solorio L, Liu JC. Collagen- and hyaluronic acid-based hydrogels and their biomedical applications. MATERIALS SCIENCE & ENGINEERING. R, REPORTS : A REVIEW JOURNAL 2021; 146:100641. [PMID: 34483486 PMCID: PMC8409465 DOI: 10.1016/j.mser.2021.100641] [Citation(s) in RCA: 73] [Impact Index Per Article: 24.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Hydrogels have been widely investigated in biomedical fields due to their similar physical and biochemical properties to the extracellular matrix (ECM). Collagen and hyaluronic acid (HA) are the main components of the ECM in many tissues. As a result, hydrogels prepared from collagen and HA hold inherent advantages in mimicking the structure and function of the native ECM. Numerous studies have focused on the development of collagen and HA hydrogels and their biomedical applications. In this extensive review, we provide a summary and analysis of the sources, features, and modifications of collagen and HA. Specifically, we highlight the fabrication, properties, and potential biomedical applications as well as promising commercialization of hydrogels based on these two natural polymers.
Collapse
Affiliation(s)
- Qinghua Xu
- Davidson School of Chemical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Jessica E. Torres
- Davidson School of Chemical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Mazin Hakim
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907, USA
| | - Paulina M Babiak
- Davidson School of Chemical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Pallabi Pal
- Davidson School of Chemical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Carly M Battistoni
- Davidson School of Chemical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Michael Nguyen
- Department of Biomedical Engineering, University of California Davis, Davis, California 95616, United States
| | - Alyssa Panitch
- Department of Biomedical Engineering, University of California Davis, Davis, California 95616, United States
| | - Luis Solorio
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907, USA
| | - Julie C. Liu
- Davidson School of Chemical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907, USA
| |
Collapse
|
37
|
The Effect of Enzymatic Crosslink Degradation on the Mechanics of the Anterior Cruciate Ligament: A Hybrid Multi-Domain Model. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11188580] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The anterior cruciate ligament’s (ACL) mechanics is an important factor governing the ligament’s integrity and, hence, the knee joint’s response. Despite many investigations in this area, the cause and effect of injuries remain unclear or unknown. This may be due to the complexity of the direct link between macro- and micro-scale damage mechanisms. In the first part of this investigation, a three-dimensional coarse-grained model of collagen fibril (type I) was developed using a bottom-up approach to investigate deformation mechanisms under tensile testing. The output of this molecular level was used later to calibrate the parameters of a hierarchical multi-scale fibril-reinforced hyper-elastoplastic model of the ACL. Our model enabled us to determine the mechanical behavior of the ACL as a function of the basic response of the collagen molecules. Modeled elastic response and damage distribution were in good agreement with the reported measurements and computational investigations. Our results suggest that degradation of crosslink content dictates the loss of the stiffness of the fibrils and, hence, damage to the ACL. Therefore, the proposed computational frame is a promising tool that will allow new insights into the biomechanics of the ACL.
Collapse
|
38
|
Zhang K, Feng Q, Fang Z, Gu L, Bian L. Structurally Dynamic Hydrogels for Biomedical Applications: Pursuing a Fine Balance between Macroscopic Stability and Microscopic Dynamics. Chem Rev 2021; 121:11149-11193. [PMID: 34189903 DOI: 10.1021/acs.chemrev.1c00071] [Citation(s) in RCA: 107] [Impact Index Per Article: 35.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Owing to their unique chemical and physical properties, hydrogels are attracting increasing attention in both basic and translational biomedical studies. Although the classical hydrogels with static networks have been widely reported for decades, a growing number of recent studies have shown that structurally dynamic hydrogels can better mimic the dynamics and functions of natural extracellular matrix (ECM) in soft tissues. These synthetic materials with defined compositions can recapitulate key chemical and biophysical properties of living tissues, providing an important means to understanding the mechanisms by which cells sense and remodel their surrounding microenvironments. This review begins with the overall expectation and design principles of dynamic hydrogels. We then highlight recent progress in the fabrication strategies of dynamic hydrogels including both degradation-dependent and degradation-independent approaches, followed by their unique properties and use in biomedical applications such as regenerative medicine, drug delivery, and 3D culture. Finally, challenges and emerging trends in the development and application of dynamic hydrogels are discussed.
Collapse
Affiliation(s)
- Kunyu Zhang
- Department of Materials Science and Engineering, Johns Hopkins University, Baltimore, Maryland 21218, United States.,Institute for NanoBioTechnology, Johns Hopkins University, Baltimore, Maryland 21218, United States
| | - Qian Feng
- Bioengineering College, Chongqing University, Chongqing 400044, People's Republic of China
| | - Zhiwei Fang
- Department of Materials Science and Engineering, Johns Hopkins University, Baltimore, Maryland 21218, United States.,Institute for NanoBioTechnology, Johns Hopkins University, Baltimore, Maryland 21218, United States
| | - Luo Gu
- Department of Materials Science and Engineering, Johns Hopkins University, Baltimore, Maryland 21218, United States.,Institute for NanoBioTechnology, Johns Hopkins University, Baltimore, Maryland 21218, United States
| | - Liming Bian
- School of Biomedical Sciences and Engineering, South China University of Technology, Guangzhou International Campus, Guangzhou 511442, People's Republic of China.,National Engineering Research Center for Tissue Restoration and Reconstruction, South China University of Technology, Guangzhou 510006, People's Republic of China.,Key Laboratory of Biomedical Engineering of Guangdong Province, South China University of Technology, Guangzhou 510006, People's Republic of China.,Key Laboratory of Biomedical Materials and Engineering of the Ministry of Education, South China University of Technology, Guangzhou 510006, People's Republic of China.,Innovation Center for Tissue Restoration and Reconstruction, South China University of Technology, Guangzhou 510006, People's Republic of China
| |
Collapse
|
39
|
Rahman MU, Fleming DF, Sinha I, Rumbaugh KP, Gordon VD, Christopher GF. Effect of collagen and EPS components on the viscoelasticity of Pseudomonas aeruginosa biofilms. SOFT MATTER 2021; 17:6225-6237. [PMID: 34109345 PMCID: PMC8283923 DOI: 10.1039/d1sm00463h] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Pseudomonas aeruginosa is an opportunistic pathogen that causes thousands of deaths every year in part due to its ability to form biofilms composed of bacteria embedded in a matrix of self-secreted extracellular polysaccharides (EPS), e-DNA, and proteins. In chronic wounds, biofilms are exposed to the host extracellular matrix, of which collagen is a major component. How bacterial EPS interacts with host collagen and whether this interaction affects biofilm viscoelasticity is not well understood. Since physical disruption of biofilms is often used in their removal, knowledge of collagen's effects on biofilm viscoelasticity may enable new treatment strategies that are better tuned to biofilms growing in host environments. In this work, biofilms are grown in the presence of different concentrations of collagen that mimic in vivo conditions. In order to explore collagen's interaction with EPS, nine strains of P. aeruginosa with different patterns of EPS production were used to grow biofilms. Particle tracking microrheology was used to characterize the mechanical development of biofilms over two days. Collagen is found to decrease biofilm compliance and increase relative elasticity regardless of the EPS present in the system. However, this effect is minimized when biofilms overproduce EPS. Collagen appears to become a de facto component of the EPS, through binding to bacteria or physical entanglement.
Collapse
Affiliation(s)
- Minhaz Ur Rahman
- Department of Mechanical Engineering, Whitacre College of Engineering, Texas Tech University, Lubbock, TX, USA.
| | - Derek F Fleming
- Department of Surgery, Texas Tech Health Sciences, Lubbock, TX, USA
| | - Indranil Sinha
- Department of Mechanical Engineering, Whitacre College of Engineering, Texas Tech University, Lubbock, TX, USA.
| | | | - Vernita D Gordon
- Department of Physics, Center for Nonlinear Dynamics, Interdisciplinary Life Sciences Graduate Programs, LaMontagne Center for Infectious Disease, The University of Texas at Austin, Austin, TX, USA
| | - Gordon F Christopher
- Department of Mechanical Engineering, Whitacre College of Engineering, Texas Tech University, Lubbock, TX, USA.
| |
Collapse
|
40
|
Dey K, Roca E, Ramorino G, Sartore L. Progress in the mechanical modulation of cell functions in tissue engineering. Biomater Sci 2021; 8:7033-7081. [PMID: 33150878 DOI: 10.1039/d0bm01255f] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
In mammals, mechanics at multiple stages-nucleus to cell to ECM-underlie multiple physiological and pathological functions from its development to reproduction to death. Under this inspiration, substantial research has established the role of multiple aspects of mechanics in regulating fundamental cellular processes, including spreading, migration, growth, proliferation, and differentiation. However, our understanding of how these mechanical mechanisms are orchestrated or tuned at different stages to maintain or restore the healthy environment at the tissue or organ level remains largely a mystery. Over the past few decades, research in the mechanical manipulation of the surrounding environment-known as substrate or matrix or scaffold on which, or within which, cells are seeded-has been exceptionally enriched in the field of tissue engineering and regenerative medicine. To do so, traditional tissue engineering aims at recapitulating key mechanical milestones of native ECM into a substrate for guiding the cell fate and functions towards specific tissue regeneration. Despite tremendous progress, a big puzzle that remains is how the cells compute a host of mechanical cues, such as stiffness (elasticity), viscoelasticity, plasticity, non-linear elasticity, anisotropy, mechanical forces, and mechanical memory, into many biological functions in a cooperative, controlled, and safe manner. High throughput understanding of key cellular decisions as well as associated mechanosensitive downstream signaling pathway(s) for executing these decisions in response to mechanical cues, solo or combined, is essential to address this issue. While many reports have been made towards the progress and understanding of mechanical cues-particularly, substrate bulk stiffness and viscoelasticity-in regulating the cellular responses, a complete picture of mechanical cues is lacking. This review highlights a comprehensive view on the mechanical cues that are linked to modulate many cellular functions and consequent tissue functionality. For a very basic understanding, a brief discussion of the key mechanical players of ECM and the principle of mechanotransduction process is outlined. In addition, this review gathers together the most important data on the stiffness of various cells and ECM components as well as various tissues/organs and proposes an associated link from the mechanical perspective that is not yet reported. Finally, beyond addressing the challenges involved in tuning the interplaying mechanical cues in an independent manner, emerging advances in designing biomaterials for tissue engineering are also explored.
Collapse
Affiliation(s)
- Kamol Dey
- Department of Applied Chemistry and Chemical Engineering, Faculty of Science, University of Chittagong, Bangladesh
| | | | | | | |
Collapse
|
41
|
Fassini D, Wilkie IC, Pozzolini M, Ferrario C, Sugni M, Rocha MS, Giovine M, Bonasoro F, Silva TH, Reis RL. Diverse and Productive Source of Biopolymer Inspiration: Marine Collagens. Biomacromolecules 2021; 22:1815-1834. [PMID: 33835787 DOI: 10.1021/acs.biomac.1c00013] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Marine biodiversity is expressed through the huge variety of vertebrate and invertebrate species inhabiting intertidal to deep-sea environments. The extraordinary variety of "forms and functions" exhibited by marine animals suggests they are a promising source of bioactive molecules and provides potential inspiration for different biomimetic approaches. This diversity is familiar to biologists and has led to intensive investigation of metabolites, polysaccharides, and other compounds. However, marine collagens are less well-known. This review will provide detailed insight into the diversity of collagens present in marine species in terms of their genetics, structure, properties, and physiology. In the last part of the review the focus will be on the most common marine collagen sources and on the latest advances in the development of innovative materials exploiting, or inspired by, marine collagens.
Collapse
Affiliation(s)
- Dario Fassini
- 3B's Research Group, I3Bs - Research Institute on Biomaterials, Biodegradables and Biomimetics, University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine, AvePark, Parque de Ciência e Tecnologia, Zona Industrial da Gandra, 4805-017 Barco, Guimarães, Portugal.,ICVS/3B's-PT Government Associate Laboratory, Braga, Guimarães, Portugal
| | - Iain C Wilkie
- Institute of Biodiversity Animal Health & Comparative Medicine, University of Glasgow, Glasgow G12 8QQ, Scotland
| | - Marina Pozzolini
- Department of Earth, Environment and Life Sciences (DISTAV), University of Genova, Via Pastore 3, 16132 Genova, Italy
| | - Cinzia Ferrario
- Dipartimento di Scienze e Politiche Ambientali, Università degli Studi di Milano, Milano, Italy, Center for Complexity & Biosystems, Dipartimento di Fisica, Università degli Studi di Milano, 20122 Milano, Italy
| | - Michela Sugni
- Dipartimento di Scienze e Politiche Ambientali, Università degli Studi di Milano, Milano, Italy, Center for Complexity & Biosystems, Dipartimento di Fisica, Università degli Studi di Milano, 20122 Milano, Italy
| | - Miguel S Rocha
- 3B's Research Group, I3Bs - Research Institute on Biomaterials, Biodegradables and Biomimetics, University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine, AvePark, Parque de Ciência e Tecnologia, Zona Industrial da Gandra, 4805-017 Barco, Guimarães, Portugal.,ICVS/3B's-PT Government Associate Laboratory, Braga, Guimarães, Portugal
| | - Marco Giovine
- Department of Earth, Environment and Life Sciences (DISTAV), University of Genova, Via Pastore 3, 16132 Genova, Italy
| | - Francesco Bonasoro
- Dipartimento di Scienze e Politiche Ambientali, Università degli Studi di Milano, Milano, Italy, Center for Complexity & Biosystems, Dipartimento di Fisica, Università degli Studi di Milano, 20122 Milano, Italy
| | - Tiago H Silva
- 3B's Research Group, I3Bs - Research Institute on Biomaterials, Biodegradables and Biomimetics, University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine, AvePark, Parque de Ciência e Tecnologia, Zona Industrial da Gandra, 4805-017 Barco, Guimarães, Portugal.,ICVS/3B's-PT Government Associate Laboratory, Braga, Guimarães, Portugal
| | - Rui L Reis
- 3B's Research Group, I3Bs - Research Institute on Biomaterials, Biodegradables and Biomimetics, University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine, AvePark, Parque de Ciência e Tecnologia, Zona Industrial da Gandra, 4805-017 Barco, Guimarães, Portugal.,ICVS/3B's-PT Government Associate Laboratory, Braga, Guimarães, Portugal
| |
Collapse
|
42
|
Bartlow CM, Mann KA, Damron TA, Oest ME. Altered mechanical behavior of demineralized bone following therapeutic radiation. J Orthop Res 2021; 39:750-760. [PMID: 32965711 PMCID: PMC8212945 DOI: 10.1002/jor.24868] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2020] [Revised: 07/15/2020] [Accepted: 09/21/2020] [Indexed: 02/04/2023]
Abstract
Post-radiotherapy (RTx) bone fragility fractures are a late-onset complication occurring in bone within or underlying the radiation field. These fractures are difficult to predict, as patients do not present with local osteopenia. Using a murine hindlimb RTx model, we previously documented decreased mineralized bone strength and fracture toughness, but alterations in material properties of the organic bone matrix are largely unknown. In this study, 4 days of fractionated hindlimb irradiation (4 × 5 Gy) or Sham irradiation was administered in a mouse model (BALB/cJ, end points: 0, 4, 8, and 12 weeks, n = 15/group/end point). Following demineralization, the viscoelastic stress relaxation, and monotonic tensile mechanical properties of tibiae were determined. Irradiated tibiae demonstrated an immediate (day after last radiation fraction) and sustained (4, 8, 12 weeks) increase in stress relaxation compared to the Sham group, with a 4.4% decrease in equilibrium stress (p < .017). While tensile strength was not different between groups, irradiated tibiae had a lower elastic modulus (-5%, p = .027) and energy to failure (-12.2%, p = .012) with monotonic loading. Gel electrophoresis showed that therapeutic irradiation (4 × 5 Gy) does not result in collagen fragmentation, while irradiation at a common sterilization dose (25 kGy) extensively fragmented collagen. These results suggest that altered collagen mechanical behavior has a role in postirradiation bone fragility, but this can occur without detectable collagen fragmentation. Statement of Clinical Significance: Therapeutic irradiation alters bone organic matrix mechanics and which contribute to diminished fatigue strength, but this does not occur via collagen fragmentation.
Collapse
Affiliation(s)
- Christopher M. Bartlow
- Department of Orthopedic Surgery State University of New York Upstate Medical University Syracuse New York USA
| | - Kenneth A. Mann
- Department of Orthopedic Surgery State University of New York Upstate Medical University Syracuse New York USA
| | - Timothy A. Damron
- Department of Orthopedic Surgery State University of New York Upstate Medical University Syracuse New York USA
| | - Megan E. Oest
- Department of Orthopedic Surgery State University of New York Upstate Medical University Syracuse New York USA
| |
Collapse
|
43
|
Use of Vibrational Optical Coherence Tomography to Analyze the Mechanical Properties of Composite Materials. SENSORS 2021; 21:s21062001. [PMID: 33809029 PMCID: PMC7998841 DOI: 10.3390/s21062001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Revised: 02/26/2021] [Accepted: 03/06/2021] [Indexed: 11/24/2022]
Abstract
Energy storage and dissipation by composite materials are important design parameters for sensors and other devices. While polymeric materials can reversibly store energy by decreased chain randomness (entropic loss) they fail to be able to dissipate energy effectively and ultimately fail due to fatigue and molecular chain breakage. In contrast, composite tissues, such as muscle and tendon complexes, store and dissipate energy through entropic changes in collagen (energy storage) and viscous losses (energy dissipation) by muscle fibers or through fluid flow of the interfibrillar matrix. In this paper we review the molecular basis for energy storage and dissipation by natural composite materials in an effort to aid in the development of improved substrates for sensors, implants and other commercial devices. In addition, we introduce vibrational optical coherence tomography, a new technique that can be used to follow energy storage and dissipation by composite materials without physically touching them.
Collapse
|
44
|
Camasão DB, Mantovani D. The mechanical characterization of blood vessels and their substitutes in the continuous quest for physiological-relevant performances. A critical review. Mater Today Bio 2021; 10:100106. [PMID: 33889837 PMCID: PMC8050780 DOI: 10.1016/j.mtbio.2021.100106] [Citation(s) in RCA: 81] [Impact Index Per Article: 27.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2020] [Revised: 02/07/2021] [Accepted: 02/27/2021] [Indexed: 11/29/2022] Open
Abstract
During the last 50 years, novel biomaterials and tissue engineering techniques have been investigated to produce alternative vascular substitutes that recapitulate the unique elastic mechanical features of blood vessels. A large variation in mechanical characterization, including the test type, protocol, and data analysis, is present in literature which complicates the comparison among studies and prevents the blooming and the advancement of this field. In addition, a limited mechanical assessment of the substitute for the intended application is often provided. In this light, this review presents the mechanical environment of blood vessels, discusses their mechanical behavior responsible for the suited blood flow into the body (non-linearity, anisotropy, hysteresis, and compliance), and compares the mechanical properties reported in literature (obtained with compression, tensile, stress-relaxation, creep, dynamic mechanical analysis, burst pressure, and dynamic compliance tests). This perspective highlights that the mechanical properties extracted through conventional tests are not always suitable indicators of the mechanical performance during the working life of a vascular substitute. The available tests can be then strategically used at different stages of the substitute development, prioritizing the simplicity of the method at early stages, and the physiological pertinence at later stages, following as much as possible ISO standards in the field. A consistent mechanical characterization focused on the behavior to which they will be subdued during real life is one key and missing element in the quest for physiological-like mechanical performance of vascular substitutes.
Collapse
Affiliation(s)
- D B Camasão
- Laboratory for Biomaterials and Bioengineering, Canada Research Chair I in Biomaterials and Bioengineering for the Innovation in Surgery, Department of Min-Met-Materials Engineering, Research Center of CHU de Québec, Division of Regenerative Medicine, Laval University, Québec, QC, G1V 0A6, Canada
| | - D Mantovani
- Laboratory for Biomaterials and Bioengineering, Canada Research Chair I in Biomaterials and Bioengineering for the Innovation in Surgery, Department of Min-Met-Materials Engineering, Research Center of CHU de Québec, Division of Regenerative Medicine, Laval University, Québec, QC, G1V 0A6, Canada
| |
Collapse
|
45
|
Ristaniemi A, Regmi D, Mondal D, Torniainen J, Tanska P, Stenroth L, Finnilä MAJ, Töyräs J, Korhonen RK. Structure, composition and fibril-reinforced poroviscoelastic properties of bovine knee ligaments and patellar tendon. J R Soc Interface 2021; 18:20200737. [PMID: 33499766 DOI: 10.1098/rsif.2020.0737] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
Tissue-level stress-relaxation of ligaments and tendons in the toe region is characterized by fast and long-term relaxations and an increase in relaxation magnitude with strain. Characterizing the compositional and structural origins of these phenomena helps in the understanding of mechanisms of ligament and tendon function and adaptation in health and disease. A three-step tensile stress-relaxation test was conducted on dumbbell-shaped pieces of bovine knee ligaments and patellar tendon (PT) (n = 10 knees). Their mechanical behaviour was characterized by a fibril-reinforced poroviscoelastic material model, able to describe characteristic times and magnitudes of fast and long-term relaxations. The crimp angle and length of tissues were measured with polarized light microscopy, while biochemical contents were determined by colorimetric biochemical methods. The long-term relaxation time was longer in the anterior cruciate ligament (ACL) and PT compared with collateral ligaments (p < 0.05). High hydroxyproline content predicted greater magnitude and shorter time of both fast and long-term relaxation. High uronic acid content predicted longer time of long-term relaxation, whereas high crimp angle predicted higher magnitude of long-term relaxation. ACL and PT are better long-term stabilizers than collateral ligaments. The long-term relaxation behaviour is affected or implied by proteoglycans and crimp angle, possibly relating to slow structural reorganization of the tissue.
Collapse
Affiliation(s)
- Aapo Ristaniemi
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - Dristi Regmi
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - Diponkor Mondal
- Research Unit of Medical Imaging, Physics and Technology, University of Oulu, Oulu, Finland
| | - Jari Torniainen
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland.,Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland
| | - Petri Tanska
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - Lauri Stenroth
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - Mikko A J Finnilä
- Research Unit of Medical Imaging, Physics and Technology, University of Oulu, Oulu, Finland
| | - Juha Töyräs
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland.,Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland.,School of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, Australia
| | - Rami K Korhonen
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| |
Collapse
|
46
|
Casari D, Michler J, Zysset P, Schwiedrzik J. Microtensile properties and failure mechanisms of cortical bone at the lamellar level. Acta Biomater 2021; 120:135-145. [PMID: 32428682 DOI: 10.1016/j.actbio.2020.04.030] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2020] [Revised: 04/09/2020] [Accepted: 04/16/2020] [Indexed: 12/15/2022]
Abstract
Bone features a remarkable combination of toughness and strength which originates from its complex hierarchical structure and motivates its investigation on multiple length scales. Here, in situ microtensile experiments were performed on dry ovine osteonal bone for the first time at the length scale of a single lamella. The micromechanical response was brittle and revealed larger ultimate tensile strength compared to the macroscale (factor of 2.3). Ultimate tensile strength for axial and transverse specimens was 0.35 ± 0.05 GPa and 0.13 ± 0.02 GPa, respectively. A significantly greater strength anisotropy relative to compression was observed (axial to transverse strength ratio of 2.7:1 for tension, 1.3:1 for compression). Fracture surface and transmission electron microscopic analysis suggested that this may be rationalized by a change in failure mode from fibril-matrix interfacial shearing for axial specimens to fibril-matrix debonding in the transverse direction. An improved version of the classic Hashin's composite failure model was applied to describe lamellar bone strength as a function of fibril orientation. Together with our experimental observations, the model suggests that cortical bone strength at the lamellar level is remarkably tolerant to variations of fibrils orientation of about ±30°. This study highlights the importance of investigating bone's hierarchical organization at several length scales for gaining a deeper understanding of its macroscopic fracture behavior. STATEMENT OF SIGNIFICANCE: Understanding bone deformation and failure behavior at different length scales of its hierarchical structure is fundamental for the improvement of bone fracture prevention, as well as for the development of multifunctional bio-inspired materials combining toughness and strength. The experiments reported in this study shed light on the microtensile properties of dry primary osteonal bone and establish a baseline from which to start further investigations in more physiological conditions. Microtensile specimens were stronger than their macroscopic counterparts by a factor of 2.3. Lamellar bone strength seems remarkably tolerant to variations of the sub-lamellar fibril orientation with respect to the loading direction (±30°). This study underlines the importance of studying bone on all length scales for improving our understanding of bone's macroscopic mechanical response.
Collapse
|
47
|
Adouni M, Mbarki R, Al Khatib F, Eilaghi A. Multiscale modeling of knee ligament biomechanics. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2021; 37:e3413. [PMID: 33174350 DOI: 10.1002/cnm.3413] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2020] [Revised: 10/02/2020] [Accepted: 11/01/2020] [Indexed: 06/11/2023]
Abstract
Knee connective tissues are mainly responsible for joint stability and play a crucial role in restraining excessive motion during regular activities. The damage mechanism of these tissues is directly linked to the microscale collagen level. However, this mechanical connection is still unclear. During this investigation, a multiscale fibril-reinforced hyper-elastoplastic model was developed and statistically calibrated. The model is accounting for the structural architecture of the soft tissue, starting from the tropocollagen molecule that forms fibrils to the whole soft tissue. Model predictions are in agreement with the results of experimental and numerical studies. Further, damage initiation and propagation in the collagen fiber were computed at knee ligaments and located mainly in the superficial layers. Results indicated higher crosslink density required higher tensile stress to elicit fibril damage. This approach is aligned with a realistic simulation of a damaging process and repair attempt. To the best of our knowledge, this is the first model published in which the connective tissue stiffness is simultaneously predicted by encompassing the mesoscopic scales between the molecular and macroscopic levels.
Collapse
Affiliation(s)
- Malek Adouni
- Physical Medicine and Rehabilitation Department, Northwestern University, Chicago, Illinois, USA
- Mechanical Engineering Department, Australian College of Kuwait, Kuwait city, Kuwait
| | - Raouf Mbarki
- Mechanical Engineering Department, Australian College of Kuwait, Kuwait city, Kuwait
| | - Fadi Al Khatib
- Mechanical Engineering Department, Australian College of Kuwait, Kuwait city, Kuwait
| | - Armin Eilaghi
- Mechanical Engineering Department, Australian College of Kuwait, Kuwait city, Kuwait
| |
Collapse
|
48
|
Dry vs. wet: Properties and performance of collagen films. Part II. Cyclic and time-dependent behaviours. J Mech Behav Biomed Mater 2020; 112:104040. [DOI: 10.1016/j.jmbbm.2020.104040] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2020] [Revised: 08/08/2020] [Accepted: 08/12/2020] [Indexed: 12/21/2022]
|
49
|
Ristaniemi A, Tanska P, Stenroth L, Finnilä MAJ, Korhonen RK. Comparison of material models for anterior cruciate ligament in tension: from poroelastic to a novel fibril-reinforced nonlinear composite model. J Biomech 2020; 114:110141. [PMID: 33302181 DOI: 10.1016/j.jbiomech.2020.110141] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2020] [Revised: 11/05/2020] [Accepted: 11/12/2020] [Indexed: 12/15/2022]
Abstract
Computational models of the knee joint are useful for evaluating stresses and strains within the joint tissues. However, the outcome of those models is sensitive to the material model and material properties chosen for ligaments, the collagen reinforced tissues connecting bone to bone. The purpose of this study was to investigate different compositionally motivated material models and further to develop a model that can accurately reproduce experimentally measured stress-relaxation data of bovine anterior cruciate ligament (ACL). Tensile testing samples were extracted from ACLs of bovine knee joints (N = 10) and subjected to a three-step stress-relaxation test at the toe region. Data from the experiments was averaged and one average finite element model was generated to replicate the experiment. Poroelastic and different fibril-reinforced poro(visco)elastic material models were applied, and their material parameters were optimized to reproduce the experimental force-time response. Material models with only fluid flow mediated relaxation were not able to capture the stress-relaxation behavior (R2 = 0.806, 0.803 and 0.938). The inclusion of the viscoelasticity of the fibrillar network improved the model prediction (R2 = 0.978 and 0.976), but the complex stress-relaxation behavior was best captured by a poroelastic model with a nonlinear two-relaxation-time strain-recruited viscoelastic fibrillar network (R2 = 0.997). The results suggest that in order to replicate the multi-step stress-relaxation behavior of ACL in tension, the fibrillar network formulation should include the complex nonlinear viscoelastic phenomena.
Collapse
Affiliation(s)
- A Ristaniemi
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland.
| | - P Tanska
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - L Stenroth
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - M A J Finnilä
- Research Unit of Medical Imaging, Physics and Technology, University of Oulu, Oulu, Finland
| | - R K Korhonen
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| |
Collapse
|
50
|
Gupta RS, Berrellez D, Chhugani N, Luna Lopez C, Maldonado A, Shah SB. Effects of paclitaxel on the viscoelastic properties of mouse sensory nerves. J Biomech 2020; 115:110125. [PMID: 33257008 DOI: 10.1016/j.jbiomech.2020.110125] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Revised: 10/23/2020] [Accepted: 11/03/2020] [Indexed: 11/18/2022]
Abstract
Paclitaxel is an effective and widely used chemotherapeutic, but also causes debilitating peripheral sensory neuropathy. Due to its influence on microtubule stability, we and others have hypothesized that paclitaxel alters neuromechanical properties. A prior study suggested that paclitaxel increases the tensile moduli of rat sensory nerves. However, the effects of paclitaxel on tissue level viscoelasticity have not been tested. In this study, sural branches of C57BL/6J mouse sciatic nerves were bilaterally excised. One nerve was treated with Ringer's solution containing paclitaxel, and the contralateral nerve with Ringer's alone. Nerves were then subject to a passive loading protocol in which peak stress, relaxed stress, and stress-relaxation dynamics were monitored at increasing strain. Elastic and tangent tensile moduli were calculated from both peak and relaxed stress-strain curves as well as failure stress were significantly elevated in paclitaxel-treated nerves compared to controls. Double-exponential fits (with τm and τn indicating fast and slow time constants, respectively) were successfully applied to model stress-relaxation. Though no significant differences in the τm and τn were found between groups, paclitaxel treatment significantly increased the variability of τm, suggesting heterogeneous effects on nerve biomechanical properties. Our data establish that paclitaxel effects at the cellular level influence tensile viscoelastic properties of nerves at the tissue level. These results have implications for understanding biomechanical influences on the progression and physical rehabilitation of paclitaxel-induced neuropathy.
Collapse
Affiliation(s)
- Rishi S Gupta
- Department of Orthopaedic Surgery, University of California, San Diego, USA
| | - Daniel Berrellez
- Posgrado en Ciencia de Materiales, Universidad de Sonora, Mexico
| | - Neha Chhugani
- Department of Bioengineering, University of California, San Diego, USA
| | - Carlos Luna Lopez
- Department of Cell Biology, California State University San Marcos, USA
| | | | - Sameer B Shah
- Department of Orthopaedic Surgery, University of California, San Diego, USA; Department of Bioengineering, University of California, San Diego, USA; Research Division, VA San Diego Healthcare System, USA.
| |
Collapse
|