1
|
John S, Yan Y, Abbasi S, Mehrmohammadi M. Ultrasound and Photoacoustic Imaging for the Guidance of Laser Ablation Procedures. SENSORS (BASEL, SWITZERLAND) 2024; 24:3542. [PMID: 38894332 PMCID: PMC11175072 DOI: 10.3390/s24113542] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2024] [Revised: 05/27/2024] [Accepted: 05/28/2024] [Indexed: 06/21/2024]
Abstract
The accuracy and efficacy of laser ablation procedures depend on the accurate placement of the laser applicator within the diseased tissue, monitoring the real-time temperature during the ablation procedure, and mapping the extent of the ablated region. Ultrasound (US) imaging has been widely used to guide ablation procedures. While US imaging offers significant advantages for guiding ablation procedures, its limitations include low imaging contrast, angular dependency, and limited ability to monitor the temperature. Photoacoustic (PA) imaging is a relatively new imaging modality that inherits the advantages of US imaging and offers enhanced capabilities for laser-guided ablations, such as accurate, angle-independent tracking of ablation catheters, the potential for quantitative thermometry, and monitoring thermal lesion formation. This work provides an overview of ultrasound-guided procedures and how different US-related artifacts limit their utility, followed by introducing PA as complementary to US as a solution to address the existing limitations and improve ablation outcomes. Furthermore, we highlight the integration of PA-driven features into existing US-guided laser ablation systems, along with their limitations and future outlooks. Integrated US/PA-guided laser ablation procedures can lead to safer and more precise treatment outcomes.
Collapse
Affiliation(s)
| | | | | | - Mohammad Mehrmohammadi
- Imaging Science, University of Rochester Medical Center, Rochester, NY 14642, USA; (S.J.); (Y.Y.); (S.A.)
| |
Collapse
|
2
|
Wang L, Ding Y, Bruno TL, Stafford RJ, Lin E, Bathala TK, Sanders JW, Ning MS, Ma J, Klopp AH, Venkatesan A, Wang J, Martirosyan KS, Frank SJ. A Novel Positive-Contrast Magnetic Resonance Imaging Line Marker for High-Dose-Rate (HDR) MRI-Assisted Radiosurgery (MARS). Cancers (Basel) 2024; 16:1922. [PMID: 38792000 PMCID: PMC11119838 DOI: 10.3390/cancers16101922] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2024] [Revised: 05/15/2024] [Accepted: 05/17/2024] [Indexed: 05/26/2024] Open
Abstract
Magnetic resonance imaging (MRI) can facilitate accurate organ delineation and optimal dose distributions in high-dose-rate (HDR) MRI-Assisted Radiosurgery (MARS). Its use for this purpose has been limited by the lack of positive-contrast MRI markers that can clearly delineate the lumen of the HDR applicator and precisely show the path of the HDR source on T1- and T2-weighted MRI sequences. We investigated a novel MRI positive-contrast HDR brachytherapy or interventional radiotherapy line marker, C4:S, consisting of C4 (visible on T1-weighted images) complexed with saline. Longitudinal relaxation time (T1) and transverse relaxation time (T2) for C4:S were measured on a 1.5 T MRI scanner. High-density polyethylene (HDPE) tubing filled with C4:S as an HDR brachytherapy line marker was tested for visibility on T1- and T2-weighted MRI sequences in a tissue-equivalent female ultrasound training pelvis phantom. Relaxivity measurements indicated that C4:S solution had good T1-weighted contrast (relative to oil [fat] signal intensity) and good T2-weighted contrast (relative to water signal intensity) at both room temperature (relaxivity ratio > 1; r2/r1 = 1.43) and body temperature (relaxivity ratio > 1; r2/r1 = 1.38). These measurements were verified by the positive visualization of the C4:S (C4/saline 50:50) HDPE tube HDR brachytherapy line marker on both T1- and T2-weighted MRI sequences. Orientation did not affect the relaxivity of the C4:S contrast solution. C4:S encapsulated in HDPE tubing can be visualized as a positive line marker on both T1- and T2-weighted MRI sequences. MRI-guided HDR planning may be possible with these novel line markers for HDR MARS for several types of cancer.
Collapse
Affiliation(s)
- Li Wang
- Department of Experimental Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA; (L.W.); (E.L.)
| | - Yao Ding
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA; (Y.D.); (J.W.)
| | - Teresa L. Bruno
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA; (T.L.B.); (M.S.N.); (A.H.K.)
| | - R. Jason Stafford
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA; (R.J.S.); (J.M.)
| | - Eric Lin
- Department of Experimental Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA; (L.W.); (E.L.)
| | - Tharakeswara K. Bathala
- Department of Diagnostic Radiology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA; (T.K.B.); (A.V.)
| | | | - Matthew S. Ning
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA; (T.L.B.); (M.S.N.); (A.H.K.)
| | - Jingfei Ma
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA; (R.J.S.); (J.M.)
| | - Ann H. Klopp
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA; (T.L.B.); (M.S.N.); (A.H.K.)
| | - Aradhana Venkatesan
- Department of Diagnostic Radiology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA; (T.K.B.); (A.V.)
| | - Jihong Wang
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA; (Y.D.); (J.W.)
| | - Karen S. Martirosyan
- Department of Physics, The University of Texas Rio Grande Valley, Brownsville, TX 78500, USA;
| | - Steven J. Frank
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA; (T.L.B.); (M.S.N.); (A.H.K.)
| |
Collapse
|
3
|
Manea E, Chitoran E, Rotaru V, Ionescu S, Luca D, Cirimbei C, Alecu M, Capsa C, Gafton B, Prutianu I, Serban D, Simion L. Integration of Ultrasound in Image-Guided Adaptive Brachytherapy in Cancer of the Uterine Cervix. Bioengineering (Basel) 2024; 11:506. [PMID: 38790373 PMCID: PMC11117609 DOI: 10.3390/bioengineering11050506] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2024] [Revised: 05/09/2024] [Accepted: 05/12/2024] [Indexed: 05/26/2024] Open
Abstract
Cervical cancer continues to be a public health concern, as it remains the second most common cancer despite screening programs. It is the third most common cause of cancer-related death for women, and the majority of cases happen in developing nations. The standard treatment for locally advanced cervical cancer involves the use of external beam radiation therapy, along with concurrent chemotherapy, followed by an image-guided adaptive brachytherapy (IGABT) boost. The five-year relative survival rate for European women diagnosed with cervical cancer was 62% between 2000 and 2007. Updated cervical cancer treatment guidelines based on IGABT have been developed by the Gynecological working group, which is composed of the Group Européen de Curiethérapie-European Society for Therapeutic Radiology and Oncology. The therapeutic strategy makes use of three-dimensional imaging, which can be tailored to the target volume and at-risk organs through the use of computed tomography or magnetic resonance imaging. Under anaesthesia, the brachytherapy implantation is carried out. Ultrasonography is utilised to assess the depth of the uterine cavity and to facilitate the dilation of the uterine canal during the application insertion. In this study, we examine data from the international literature regarding the application of ultrasound in cervical cancer brachytherapy.
Collapse
Affiliation(s)
- Elena Manea
- Department of Radiotherapy, Regional Institute of Oncology, 700483 Iasi, Romania; (E.M.)
- “Gr. T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania
| | - Elena Chitoran
- “Carol Davila” University of Medicine and Pharmacy, 050474 Bucharest, Romania; (S.I.)
- General Surgery and Surgical Oncology Department I, Bucharest Institute of Oncology “Prof. Dr. Al. Trestioreanu”, 022328 Bucharest, Romania
| | - Vlad Rotaru
- “Carol Davila” University of Medicine and Pharmacy, 050474 Bucharest, Romania; (S.I.)
- General Surgery and Surgical Oncology Department I, Bucharest Institute of Oncology “Prof. Dr. Al. Trestioreanu”, 022328 Bucharest, Romania
| | - Sinziana Ionescu
- “Carol Davila” University of Medicine and Pharmacy, 050474 Bucharest, Romania; (S.I.)
- General Surgery and Surgical Oncology Department I, Bucharest Institute of Oncology “Prof. Dr. Al. Trestioreanu”, 022328 Bucharest, Romania
| | - Dan Luca
- “Carol Davila” University of Medicine and Pharmacy, 050474 Bucharest, Romania; (S.I.)
- General Surgery and Surgical Oncology Department I, Bucharest Institute of Oncology “Prof. Dr. Al. Trestioreanu”, 022328 Bucharest, Romania
| | - Ciprian Cirimbei
- “Carol Davila” University of Medicine and Pharmacy, 050474 Bucharest, Romania; (S.I.)
- General Surgery and Surgical Oncology Department I, Bucharest Institute of Oncology “Prof. Dr. Al. Trestioreanu”, 022328 Bucharest, Romania
| | - Mihnea Alecu
- “Carol Davila” University of Medicine and Pharmacy, 050474 Bucharest, Romania; (S.I.)
- General Surgery and Surgical Oncology Department I, Bucharest Institute of Oncology “Prof. Dr. Al. Trestioreanu”, 022328 Bucharest, Romania
| | - Cristina Capsa
- Radiology and Medical Imaging Department, Bucharest Institute of Oncology “Prof. Dr. Al. Trestioreanu”, 022328 Bucharest, Romania
| | - Bogdan Gafton
- Department of Radiotherapy, Regional Institute of Oncology, 700483 Iasi, Romania; (E.M.)
- “Gr. T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania
| | - Iulian Prutianu
- “Gr. T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania
- Department of Morpho-Functional Sciences I—Histology, University of Medicine and Pharmacy “Gr. T. Popa”, 700483 Iasi, Romania
| | - Dragos Serban
- “Carol Davila” University of Medicine and Pharmacy, 050474 Bucharest, Romania; (S.I.)
- Surgery Department IV, Bucharest Clinical Emergency Hospital, 050098 Bucharest, Romania
| | - Laurentiu Simion
- “Carol Davila” University of Medicine and Pharmacy, 050474 Bucharest, Romania; (S.I.)
- General Surgery and Surgical Oncology Department I, Bucharest Institute of Oncology “Prof. Dr. Al. Trestioreanu”, 022328 Bucharest, Romania
| |
Collapse
|
4
|
Berger D, Van Dyk S, Beaulieu L, Major T, Kron T. Modern Tools for Modern Brachytherapy. Clin Oncol (R Coll Radiol) 2023:S0936-6555(23)00182-6. [PMID: 37217434 DOI: 10.1016/j.clon.2023.05.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Revised: 03/28/2023] [Accepted: 05/04/2023] [Indexed: 05/24/2023]
Abstract
This review aims to showcase the brachytherapy tools and technologies that have emerged during the last 10 years. Soft-tissue contrast using magnetic resonance and ultrasound imaging has seen enormous growth in use to plan all forms of brachytherapy. The era of image-guided brachytherapy has encouraged the development of advanced applicators and given rise to the growth of individualised 3D printing to achieve reproducible and predictable implants. These advances increase the quality of implants to better direct radiation to target volumes while sparing normal tissue. Applicator reconstruction has moved beyond manual digitising, to drag and drop of three-dimensional applicator models with embedded pre-defined source pathways, ready for auto-recognition and automation. The simplified TG-43 dose calculation formalism directly linked to reference air kerma rate of high-energy sources in the medium water remains clinically robust. Model-based dose calculation algorithms accounting for tissue heterogeneity and applicator material will advance the field of brachytherapy dosimetry to become more clinically accurate. Improved dose-optimising toolkits contribute to the real-time and adaptive planning portfolio that harmonises and expedites the entire image-guided brachytherapy process. Traditional planning strategies remain relevant to validate emerging technologies and should continue to be incorporated in practice, particularly for cervical cancer. Overall, technological developments need commissioning and validation to make the best use of the advanced features by understanding their strengths and limitations. Brachytherapy has become high-tech and modern by respecting tradition and remaining accessible to all.
Collapse
Affiliation(s)
- D Berger
- International Atomic Energy Agency, Vienna International Centre, Vienna, Austria.
| | - S Van Dyk
- Radiation Therapy Services, Division of Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, Australia
| | - L Beaulieu
- Service de Physique Médicale et Radioprotection, et Axe Oncologie du Centre de Recherche du CHU de Québec, CHU de Québec, Québec, Canada; Département de Physique, de Génie Physique et d'Optique et Centre de Recherche sur le Cancer, Université Laval, Québec, Canada
| | - T Major
- Radiotherapy Centre, National Institute of Oncology, Budapest, Hungary; Department of Oncology, Semmelweis University, Budapest, Hungary
| | - T Kron
- Peter MacCallum Cancer Centre and Sir Peter MacCallum Department of Oncology, University of Melbourne, Melbourne, Australia; Centre for Medical Radiation Physics, University of Wollongong, Wollongong, Australia
| |
Collapse
|
5
|
Zhang Z, Zhang N, Cheng G. Application of three-dimensional multi-imaging combination in brachytherapy of cervical cancer. LA RADIOLOGIA MEDICA 2023; 128:588-600. [PMID: 37138200 DOI: 10.1007/s11547-023-01632-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Accepted: 04/12/2023] [Indexed: 05/05/2023]
Abstract
BACKGROUND Three-dimensional (3D) imaging has an important role in brachytherapy and the treatment of cervical cancer. The main imaging methods used in the cervical cancer brachytherapy include magnetic resonance imaging (MRI), computer tomography (CT), ultrasound (US), and positron emission tomography (PET). However, single-imaging methods have certain limitations compared to multi-imaging. The application of multi-imaging can make up for the shortcomings and provide a more suitable imaging selection for brachytherapy. PURPOSE This review details the situation and scope of existing multi-imaging combination methods in cervical cancer brachytherapy and provides a reference for medical institutions. MATERIALS AND METHODS Searched the literature related to application of three-dimensional multi-imaging combination in brachytherapy of cervical cancer in PubMed/Medline and Web of Science electronic databases. Summarized the existing combined imaging methods and the application of each method in cervical cancer brachytherapy. CONCLUSION The current imaging combination methods mainly include MRI/CT, US/CT, MRI/US, and MRI/PET. The combination of two imaging tools can be used for applicator implantation guidance, applicator reconstruction, target and organs at risk (OAR) contouring, dose optimization, prognosis evaluation, etc., which provides a more suitable imaging choice for brachytherapy.
Collapse
Affiliation(s)
- Zhaoming Zhang
- Department of Radiation Oncology, China-Japan Union Hospital of Jilin University, No.126 Xiantai Street, Changchun, China
| | - Ning Zhang
- Department of Radiation Oncology, China-Japan Union Hospital of Jilin University, No.126 Xiantai Street, Changchun, China
| | - Guanghui Cheng
- Department of Radiation Oncology, China-Japan Union Hospital of Jilin University, No.126 Xiantai Street, Changchun, China.
| |
Collapse
|
6
|
Van Elburg D, Roumeliotis M, Fenster A, Phan T, Meyer T. Technical Note: Commissioning of an ultrasound-compatible surrogate vaginal cylinder for transvaginal ultrasound-based gynecologic high-dose-rate brachytherapy. Med Phys 2022; 49:2203-2211. [PMID: 35199856 DOI: 10.1002/mp.15559] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2021] [Revised: 01/19/2022] [Accepted: 02/12/2022] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To provide a comprehensive set of commissioning tests for clinical implementation of three-dimensional transvaginal ultrasound (3D TVUS) as a replacement of computed tomography (CT) for applicator reconstruction in gynecologic intracavitary high-dose-rate brachytherapy with a multi-channel vaginal cylinder. METHODS We introduce an ultrasound-compatible "surrogate" vaginal cylinder (SVC) for reconstruction of Elekta's CT-MR Multi Channel Applicator (MCVC) in 3D TVUS. The MCVC is digitized over the SVC in 3DUS using digital library model overlay. Consulting guidelines from various sources (CPQR, GEC-ESTRO, AAPM), we identify and describe three tests specific to commissioning the SVC: 1) verification of SVC outer dimensions, 2) source position accuracy of MCVC digitization over the SVC in 3D TVUS, and 3) MRI/US registration error. RESULTS The SVC outer dimensions (diameter and A-D marker locations) were well matched to the MCVC, however a 0.6 mm discrepancy in length between cylinder tips was observed. Source position accuracy was within 1 mm (tolerance recommended by CPQR) when reconstructing the MCVC in 3D TVUS. Dice similarity coefficients and target registration error for MRI/3D TVUS registration was similar to MRI/CT registration, which is the clinical standard. CONCLUSIONS These commissioning tests are performed using institutional equipment but provide the framework for any practitioners to repeat in their own setup, to demonstrate safe adoption of the 3D TVUS system for patient treatments. We demonstrate that MRI/US-based workflow achieves similar source position accuracy and image registration error as standard MRI/CT, which is consistent with standard tolerances. This is a critical step towards replacement of CT with US in gynecologic high-dose-rate brachytherapy treatments with the MCVC. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Devin Van Elburg
- Department of Physics & Astronomy, University of Calgary, Calgary, AB, T2N 1N4, Canada.,Medical Physics Department, Tom Baker Cancer Centre, Calgary, AB, T2N 4N2, Canada
| | - Michael Roumeliotis
- Department of Physics & Astronomy, University of Calgary, Calgary, AB, T2N 1N4, Canada.,Medical Physics Department, Tom Baker Cancer Centre, Calgary, AB, T2N 4N2, Canada.,Department of Oncology, University of Calgary, Calgary, AB, T2N 1N4, Canada
| | - Aaron Fenster
- School of Biomedical Engineering, University of Western Ontario, London ON, N6A 3K7, Canada.,Robarts Research Institute, University of Western Ontario, London ON, N6A 5B7, Canada
| | - Tien Phan
- Department of Oncology, University of Calgary, Calgary, AB, T2N 1N4, Canada
| | - Tyler Meyer
- Department of Physics & Astronomy, University of Calgary, Calgary, AB, T2N 1N4, Canada.,Medical Physics Department, Tom Baker Cancer Centre, Calgary, AB, T2N 4N2, Canada.,Department of Oncology, University of Calgary, Calgary, AB, T2N 1N4, Canada
| |
Collapse
|
7
|
Comparative dosimetry of brachytherapy treatment planning between a volume-based plan by CT and a point-based plan by TAUS in CT datasets for brachytherapy. JOURNAL OF RADIOTHERAPY IN PRACTICE 2021. [DOI: 10.1017/s1460396921000595] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Abstract
Aim:
To evaluate comparative dosimetry of brachytherapy treatment planning between a volume-based plan by computed tomography (CT) and a point-based plan by transabdominal ultrasound (TAUS) in CT datasets for brachytherapy.
Materials and methods:
From 2019 to 2021, 59 different datasets of CT images were collected from 38 patients treated by intracavitary brachytherapy with tandem ovoid or tandem ring applicators. At that time, TAUS was performed to prevent uterine perforation and to evaluate topography of the cervix during application. In volume-based planning by CT, the target dose was used to keep the dose at 90% of high-risk clinical target volume (HR-CTV), to give a dose of at least 7Gy, while in the point-based plan by TAUS, the target dose was used to keep the minimum dose to eight cervix reference points (measured by TAUS), to give a dose of at least 7Gy. The doses to targets and organs at risk were evaluated and compared between volume-based planning by CT and the point-based plan by TAUS.
Results:
Of 59 fractions, a tandem ovoid applicator was used in 48 fractions (81·3%). In the volume-based plan by CT, the mean doses to HR-CTV(D90), intermediate-risk clinical target volume (IR-CTV)(D90), bladder(D2cc), rectum(D2cc) and sigmoid colon(D2cc) were 7·0, 3·9, 4·9, 2·9 and 3·3 Gy, respectively, while in the point-based plan by TAUS, the mean doses to HR-CTV(D90), IR-CTV(D90), bladder(D2cc), rectum(D2cc) and sigmoid colon(D2cc) were 8·2, 4·6, 5·9, 3·4 and 3·9 Gy, respectively. The percentages of mean dose differences between TAUS and CT of HR-CTV(D90), IR-CTV(D90), bladder(D2cc), rectum(D2cc) and sigmoid colon(D2cc) were 17·7, 19·5, 20·5, 19·5, 21·3 and 19·8%, respectively. With the target dose to the point-based plan by TAUS (7 Gy to the cervix reference points), this was close to D98 of HR-CTV with a mean percentage of difference of 0·6%.
Findings:
The point-based plan by TAUS showed higher values to targets and organs at risk than the volume-based plan by CT. With the point-based plan by TAUS, it was close to D98 of HR-CTV.
Collapse
|
8
|
Dickhoff LR, Vrancken Peeters MJ, Bosman PA, Alderliesten T. Therapeutic applications of radioactive sources: from image-guided brachytherapy to radio-guided surgical resection. THE QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING : OFFICIAL PUBLICATION OF THE ITALIAN ASSOCIATION OF NUCLEAR MEDICINE (AIMN) [AND] THE INTERNATIONAL ASSOCIATION OF RADIOPHARMACOLOGY (IAR), [AND] SECTION OF THE SOCIETY OF... 2021; 65:190-201. [PMID: 34105339 DOI: 10.23736/s1824-4785.21.03370-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
It is well known nowadays that radioactivity can destroy the living cells it interacts with. It is therefore unsurprising that radioactive sources, such as iodine-125, were historically developed for treatment purposes within radiation oncology with the goal of damaging malignant cells. However, since then, new techniques have been invented that make creative use of the same radioactivity properties of these sources for medical applications. Here, we review two distinct kinds of therapeutic uses of radioactive sources with applications to prostate, cervical, and breast cancer: brachytherapy and radioactive seed localization. In brachytherapy (BT), the radioactive sources are used for internal radiation treatment. Current approaches make use of real-time image guidance, for instance by means of magnetic resonance imaging, ultrasound, computed tomography, and sometimes positron emission tomography, depending on clinical availability and cancer type. Such image-guided BT for prostate and cervical cancer presents a promising alternative and/or addition to external beam radiation treatments or surgical resections. Radioactive sources can also be used for radio-guided tumor localization during surgery, for which the example of iodine-125 seed use in breast cancer is given. Radioactive seed localization (RSL) is increasingly popular as an alternative tumor localization technique during breast cancer surgery. Advantages of applying RSL include added flexibility in the clinical scheduling logistics, an increase in tumor localization accuracy, and higher patient satisfaction; safety measures do however have to be employed. We exemplify the implementation of RSL in a clinic through experiences at the Netherlands Cancer Institute.
Collapse
Affiliation(s)
- Leah R Dickhoff
- Department of Radiation Oncology, Leiden University Medical Center, Leiden, The Netherlands -
| | - Marie-Jeanne Vrancken Peeters
- Department of Surgical Oncology, Netherlands Cancer Institute - Antoni van Leeuwenhoek, Amsterdam, The Netherlands.,Department of Surgery, Amsterdam University Medical Centers, Amsterdam, The Netherlands
| | - Peter A Bosman
- Life Sciences and Health group, Centrum Wiskunde & Informatica, Amsterdam, The Netherlands
| | - Tanja Alderliesten
- Department of Radiation Oncology, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
9
|
Qing K, Yue NJ, Hathout L, Ma C, Reyhan M, Zhu J, Nie K, Monte G, Vergalasova I. The combined use of 2D scout and 3D axial CT images to accurately determine the catheter tips for high-dose-rate brachytherapy plans. J Appl Clin Med Phys 2021; 22:273-278. [PMID: 33638579 PMCID: PMC7984491 DOI: 10.1002/acm2.13184] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2020] [Revised: 11/23/2020] [Accepted: 02/06/2021] [Indexed: 11/09/2022] Open
Abstract
Purpose To develop a method combining CT scout images with axial images to improve the localization accuracy of catheter tips in high‐dose‐rate (HDR) brachytherapy treatments. Materials and Methods CT scout images were utilized along with conventionally reconstructed axial images to aid the localization of catheter tips used during HDR treatment planning. A method was developed to take advantage of the finer image resolution of the scout images to more precisely identify the tip coordinates. The accuracies of this method were compared with the conventional method based on the axial CT images alone, for various slice thicknesses, in a computed tomography dose index (CTDI) head phantom. A clinical case which involved multiple interstitial catheters was also selected for the evaluation of this method. Locations of the catheter tips were reconstructed with the conventional CT‐based method and this newly developed method, respectively. Location coordinates obtained via both methods were quantitatively compared. Results Combination of the scout and axial CT images improved the accuracy of identification and reconstruction of catheter tips along the longitudinal direction (i.e., head‐to‐foot direction, more or less parallel to the catheter tracks), compared to relying on the axial CT images alone. The degree of improvement was dependent on CT slice thickness. For the clinical patient case, the coordinate differences of the reconstructed catheter tips were 2.6 mm ± 0.9 mm in the head‐to‐foot direction, 0.4 mm ± 0.2 mm in the left‐to‐right direction, and 0.6 mm ± 0.2 mm in the anterior‐to‐posterior direction, respectively. Conclusion Combining CT scout and axial images demonstrates the ability to provide a more accurate identification and reconstruction of the interstitial catheter tips for HDR brachytherapy treatment, especially in the longitudinal direction. The method developed in this work has the potential to be implemented clinically together with automatic segmentation in modern brachytherapy treatment planning systems, in order to improve the reconstruction accuracy of HDR catheters.
Collapse
Affiliation(s)
- Kun Qing
- Department of Radiation Oncology, Cancer Institute of New Jersey, Rutgers University, New Brunswick, NJ, 08901, USA.,Department of Radiation Oncology, City of Hope National Medical Center, Duarte, CA, 91010, USA
| | - Ning J Yue
- Department of Radiation Oncology, Cancer Institute of New Jersey, Rutgers University, New Brunswick, NJ, 08901, USA
| | - Lara Hathout
- Department of Radiation Oncology, Cancer Institute of New Jersey, Rutgers University, New Brunswick, NJ, 08901, USA
| | - Chi Ma
- Department of Radiation Oncology, Cancer Institute of New Jersey, Rutgers University, New Brunswick, NJ, 08901, USA
| | - Meral Reyhan
- Department of Radiation Oncology, Cancer Institute of New Jersey, Rutgers University, New Brunswick, NJ, 08901, USA
| | - Jiahua Zhu
- Department of Radiation Oncology, Cancer Institute of New Jersey, Rutgers University, New Brunswick, NJ, 08901, USA
| | - Ke Nie
- Department of Radiation Oncology, Cancer Institute of New Jersey, Rutgers University, New Brunswick, NJ, 08901, USA
| | - Gilbert Monte
- Department of Radiation Oncology, Cancer Institute of New Jersey, Rutgers University, New Brunswick, NJ, 08901, USA
| | - Irina Vergalasova
- Department of Radiation Oncology, Cancer Institute of New Jersey, Rutgers University, New Brunswick, NJ, 08901, USA
| |
Collapse
|
10
|
Ingle M, Lalondrelle S. Current Status of Anatomical Magnetic Resonance Imaging in Brachytherapy and External Beam Radiotherapy Planning and Delivery. Clin Oncol (R Coll Radiol) 2020; 32:817-827. [PMID: 33169690 DOI: 10.1016/j.clon.2020.10.009] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2020] [Revised: 10/06/2020] [Accepted: 10/08/2020] [Indexed: 02/06/2023]
Abstract
Radiotherapy planning and delivery have dramatically improved in recent times. Imaging is key to a successful three-dimensional and increasingly four-dimensional based pathway with computed tomography embedded as the backbone modality. Computed tomography has significant limitations for many tumour sites where soft-tissue discrimination is suboptimal, and where magnetic resonance imaging (MRI) has largely superseded in the diagnostic arena. MRI is increasingly used together with computed tomography in the radiotherapy planning pathway and is now established as a prerequisite for several tumours. With the advent of combined MRI and linear accelerator (MR-linac) systems, a transition to MRI-based radiotherapy planning is becoming reality, with increasing experience and research involving these new platforms. In this overview, we aim to highlight how magnetic resonance-guided imaging has improved radiotherapy, using gynaecological malignancies to illustrate, in both external beam radiotherapy and image-guided brachytherapy, and will assess the early evidence for magnetic resonance-guided radiotherapy using combined MR-linac systems.
Collapse
Affiliation(s)
- M Ingle
- Royal Marsden NHS Foundation Trust, Sutton, Surrey, UK; Institute of Cancer Research, London, UK
| | - S Lalondrelle
- Royal Marsden NHS Foundation Trust, Sutton, Surrey, UK; Institute of Cancer Research, London, UK.
| |
Collapse
|
11
|
Clinical utility and value contribution of an MRI-positive line marker for image-guided brachytherapy in gynecologic malignancies. Brachytherapy 2020; 19:305-315. [DOI: 10.1016/j.brachy.2019.12.005] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2019] [Revised: 11/29/2019] [Accepted: 12/30/2019] [Indexed: 01/19/2023]
|