1
|
Pan J, Liu Y, Lin Q, Deng Y, Luo Y, Zhao Z, Wei L, Huang J, Wang J. Reducing the molecular oxygen activation energy barrier by increasing Fe-O bonds to eliminate antibiotics and their resistance genes. JOURNAL OF HAZARDOUS MATERIALS 2024; 486:137008. [PMID: 39733750 DOI: 10.1016/j.jhazmat.2024.137008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2024] [Revised: 12/10/2024] [Accepted: 12/24/2024] [Indexed: 12/31/2024]
Abstract
Sulfamethoxazole (SMX) and its antibiotic resistance genes (ARGs) are potential threats to public health. Microwave catalytic technology is an efficient environmental remediation technology, and a reasonable design of the catalyst enables the system to achieve an ideal remediation effect under low microwave power. In this study, a microwave catalyst (FeCO-2) that activates molecular oxygen (O2) was designed on the basis of rational theoretical organization. Density functional theory (DFT) calculations were used to predict the catalytic performance of FeCO-2 in the microwave field. The mechanism of active substance generation and successful construction of the MW/FeCO-2 catalytic system were verified by experimental studies. The abundance of Fe-O bonds alters the electronic structure of the iron carbide material (Fe@C), adjusts the conduction band potential of the material, reduces the reaction energy barrier, facilitates exciton dissociation under microwave, and facilitate O2 activation. The application of the MW/FeCO-2 system was verified with secondary effluent from a farm wastewater treatment process: 90.62 % SMX and over 86.77 % of ARGs were removed within 15 min. This study provides a new technique to efficiently simultaneously eliminate antibiotics and their resistance genes. In addition, this study provides ideas for the construction of a microwave catalytic system and explains the mechanism of the microwave catalytic process.
Collapse
Affiliation(s)
- Jieyi Pan
- Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, Guangdong Industrial Contaminated Site Remediation Technology and Equipment Engineering Research Center, School of Environmental Science and Engineering, Guangdong University of Technology, Guangzhou 510006, China
| | - Yuxin Liu
- Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, Guangdong Industrial Contaminated Site Remediation Technology and Equipment Engineering Research Center, School of Environmental Science and Engineering, Guangdong University of Technology, Guangzhou 510006, China
| | - Qintie Lin
- Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, Guangdong Industrial Contaminated Site Remediation Technology and Equipment Engineering Research Center, School of Environmental Science and Engineering, Guangdong University of Technology, Guangzhou 510006, China.
| | - Yirong Deng
- Guangdong Laboratory of Soil Pollution Fate and Risk Management in Earth's Critical Zone and Guangdong Key Laboratory of Contaminated Environmental Management and Remediation, Guangdong Provincial Academy of Environmental Science, Guangzhou 510045, China
| | - Yang Luo
- Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, Guangdong Industrial Contaminated Site Remediation Technology and Equipment Engineering Research Center, School of Environmental Science and Engineering, Guangdong University of Technology, Guangzhou 510006, China
| | - Zirui Zhao
- Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, Guangdong Industrial Contaminated Site Remediation Technology and Equipment Engineering Research Center, School of Environmental Science and Engineering, Guangdong University of Technology, Guangzhou 510006, China
| | - Longyi Wei
- Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, Guangdong Industrial Contaminated Site Remediation Technology and Equipment Engineering Research Center, School of Environmental Science and Engineering, Guangdong University of Technology, Guangzhou 510006, China
| | - Jianwen Huang
- Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, Guangdong Industrial Contaminated Site Remediation Technology and Equipment Engineering Research Center, School of Environmental Science and Engineering, Guangdong University of Technology, Guangzhou 510006, China
| | - Jinguo Wang
- Guangzhou Environmental Technology Center, Guangzhou, Guangdong 510235, China
| |
Collapse
|
2
|
Zhang Y, Zuo S, Zheng Q, Yu G, Wang Y. Removal of antibiotic resistant bacteria and antibiotic resistance genes by an electrochemically driven UV/chlorine process for decentralized water treatment. WATER RESEARCH 2024; 265:122298. [PMID: 39173362 DOI: 10.1016/j.watres.2024.122298] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2024] [Revised: 08/03/2024] [Accepted: 08/16/2024] [Indexed: 08/24/2024]
Abstract
The UV/chlorine (UV/Cl2) process is a developing advanced oxidation process and can efficiently remove antibiotic resistant bacteria (ARB) and antibiotic resistance genes (ARGs). However, the transportation and storage of chlorine solutions limit the application of the UV/Cl2 process, especially for decentralized water treatment. To overcome the limitation, an electrochemically driven UV/Cl2 process (E-UV/Cl2) where Cl2 can be electrochemically produced in situ from anodic oxidation of chloride (Cl-) ubiquitously present in various water matrices was evaluated in this study. >5-log inactivation of the ARB (E. coli) was achieved within 5 s of the E-UV/Cl2 process, and no photoreactivation of the ARB was observed after the treatment. In addition to the ARB, intracellular and extracellular ARGs (tetA, sul1, sul2, and ermB) could be effectively degraded (e.g., log(C0/C) > 4 for i-ARGs) within 5 min of the E-UV/Cl2 process. Atomic force microscopy showed that the most of the i-ARGs were interrupted into short fragments (< 30 nm) during the E-UV/Cl2 process, which can thus effectively prevent the self-repair of i-ARGs and the horizontal gene transfer. Modelling results showed that the abatement efficiencies of i-ARG correlated positively with the exposures of •OH, Cl2-•, and ClO• during the E-UV/Cl2 process. Due to the short treatment time (5 min) required for ARB and ARG removal, insignificant concentrations of trihalomethanes (THMs) were generated during of the E-UV/Cl2 process, and the energy consumption (EEO) of ARG removal was ∼0.20‒0.27 kWh/m3-log, which is generally comparable to that of the UV/Cl2 process (0.18-0.23 kWh/m3-log). These results demonstrate that the E-UV/Cl2 process can provide a feasible and attractive alternative to the UV/Cl2 process for ARB and ARG removal in decentralized water treatment system.
Collapse
Affiliation(s)
- Yinqiao Zhang
- State of Key Laboratory of Natural Medicines, School of Engineering, China Pharmaceutical University, Nanjing 211198, China; School of Environment, Beijing Key Laboratory for Emerging Organic Contaminants Control, State Key Joint Laboratory of Environmental Simulation and Pollution Control, Tsinghua University, Beijing 100084, China
| | - Sijin Zuo
- State of Key Laboratory of Natural Medicines, School of Engineering, China Pharmaceutical University, Nanjing 211198, China
| | - Quan Zheng
- China State Construction Hailong Technology Company Ltd., Shenzhen 518045, China
| | - Gang Yu
- Advanced Interdisciplinary Institute of Environment and Ecology, Beijing Normal University, Zhuhai 519087, China
| | - Yujue Wang
- School of Environment, Beijing Key Laboratory for Emerging Organic Contaminants Control, State Key Joint Laboratory of Environmental Simulation and Pollution Control, Tsinghua University, Beijing 100084, China.
| |
Collapse
|
3
|
Dong Z, Yao J, Hu Z, Yang J, Zhang Y. Insight into roles of carbon anodes for removal of refractory organic contaminants in electro-peroxone system: Mechanism, performance and stability. JOURNAL OF HAZARDOUS MATERIALS 2024; 469:133957. [PMID: 38452678 DOI: 10.1016/j.jhazmat.2024.133957] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2023] [Revised: 01/29/2024] [Accepted: 03/03/2024] [Indexed: 03/09/2024]
Abstract
Electro-peroxone (EP) is a novel technique for the removal of refractory organic contaminants (ROCs), while the role of anode in this system is neglected. In this work, the EP system with graphite felt anode (EP-GF) and activated carbon fiber anode (EP-ACF) was developed to enhance ibuprofen (IBP) removal. The results showed that 91.2% and 98.6% of IBP was removed within 20 min in EP-GF and EP-ACF, respectively. Hydroxy radical (O⋅H) was identified as the dominant reactive species, contributing 80.9% and 54.0% of IBP removal in EP-ACF and EP-GF systems, respectively. The roles of adsorption in EP-ACF and direct electron transfer in EP-GF cannot be ignored. Due to the differences in mechanism, EP-GF and EP-ACF systems were suitable for the removal of O⋅H-resistant ROCs (e.g., oxalic acid and pyruvic acid) and non-O⋅H-resistant ROCs (e.g., IBP and nitrobenzene), respectively. Both systems had excellent stability relying on the introduction of oxygen functional groups on the anode, and their electrolysis energy consumption was significantly lower than that of EP-Pt system. The three degradation pathways of IBP were proposed, and the toxicity of intermediates were evaluated. In general, carbon anodes have a good application prospect in the removal of ROCs in EP systems.
Collapse
Affiliation(s)
- Zekun Dong
- College of Civil Engineering and Architecture, Zhejiang University, Hangzhou 310058, China; Key Laboratory of Drinking Water Safety and Distribution Technology of Zhejiang Province, Hangzhou 310058, China
| | - Jie Yao
- Power China Huadong Engineering Corporation Limited, Hangzhou 310023, China
| | - Zhihui Hu
- College of Civil Engineering and Architecture, Zhejiang University, Hangzhou 310058, China; Key Laboratory of Drinking Water Safety and Distribution Technology of Zhejiang Province, Hangzhou 310058, China
| | - Jiao Yang
- College of Environmental and Resources Sciences, Zhejiang University, Hangzhou 310058, China
| | - Yan Zhang
- College of Civil Engineering and Architecture, Zhejiang University, Hangzhou 310058, China; Key Laboratory of Drinking Water Safety and Distribution Technology of Zhejiang Province, Hangzhou 310058, China.
| |
Collapse
|
4
|
Zhao B, Park K, Kondo D, Wada H, Nakada N, Nishimura F, Ihara M, Tanaka H. Comparison on removal performance of virus, antibiotic-resistant bacteria, cell-associated and cell-free antibiotic resistance genes, and indicator chemicals by ozone in the filtrated secondary effluent of a sewage treatment plant. JOURNAL OF HAZARDOUS MATERIALS 2024; 465:133347. [PMID: 38150766 DOI: 10.1016/j.jhazmat.2023.133347] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 11/21/2023] [Accepted: 12/20/2023] [Indexed: 12/29/2023]
Abstract
Due to the widespread appearance of viruses, antibiotic-resistant bacteria (ARBs), and antibiotic resistance genes (ARGs) in the aquatic environment, more powerful oxidation processes such as ozonation are needed to enhance the efficiency of their inactivation and removal during wastewater treatment. However, information is lacking on the elimination rates of viruses, ARBs, cell-associated ARGs (ca-ARGs), and cell-free ARGs (cf-ARGs) during ozonation. This study examined the kinetics and dose-dependent inactivation of a virus (MS2 coliphage) and an ARB (Ampicillin-resistant [AmpR] E. coli) and the removal of ca- and cf-ARGs (plasmid-encoded blaTEM) by ozonation in a filtered secondary effluent (SE) of a municipal sewage treatment plant (STP). In addition, the ozonation kinetics of carbamazepine (CBZ) and metoprolol (MTP)-ubiquitous organic micropollutants with different removal rate constants-were also investigated in order to monitor their effectiveness as indicators for the abovementioned biological risk factors. Our results showed that ozonation was an efficient way to remove MS2, AmpRE. coli, ARGs, CBZ, and MTP. We investigated the kinetics of their inactivation/removal with respect to exposure in terms of CT (dissolved ozone concentration C and contact time T) value, and found their inactivation/removal constants were in the following order: MS2 (8.66 ×103 M-1s-1) ≈ AmpRE. coli (8.19 ×103 M-1s-1) > cf-ARG (3.95 ×103 M-1s-1) > CBZ (3.21 ×103 M-1s-1) > ca-ARG (2.48×103 M-1s-1) > MTP (8.35 ×102 M-1s-1). In terms of specific ozone dose, > 5-log inactivation of MS2 was observed at > 0.30 mg O3/mg DOC, while > 5-log inactivation of AmpRE. coli was confirmed at 1.61-2.35 mg O3/mg DOC. Moreover, there was almost no removal of ca-ARG when the specific ozone dose was < 0.68 mg O3/mg DOC. However, 2.86-3.42-log removal of ca-ARG was observed at 1.27-1.31 mg O3/mg DOC, while 1.14-1.36-log removal of cf-ARG was confirmed at 3.60-4.30 mg O3/mg DOC. As alternative indicators, > 4-log removal of CBZ was observed at > 1.00 mg O3/mg DOC, while > 2-log removal of MTP was confirmed at > 2.00 mg O3/mg DOC. Thus, it was observed that inactivation of E. coli needs a greater ozone dose to achieve the same level of inactivation of AmpRE. coli; for ARGs, cf-ARG can persist longer than ca-ARG if low dosages of ozone are applied in the filtrated SE, CBZ might act as an indicator with which to monitor the inactivation of viruses and ARBs, while MTP might act as an indicator with which to monitor removal of ARGs. Moreover, cf-ARG cannot be neglected even after ozonation due to the possibility that ca-ARGs can become cf-ARGs during ozonation and be discharged with the final effluent, posing a potential risk to the receiving environment.
Collapse
Affiliation(s)
- Bo Zhao
- Key Laboratory of Integrated Regulation and Resource Development of Shallow Lakes of Ministry of Education, College of Environment, Hohai University, Nanjing 210098, PR China; Research Center for Environmental Quality Management, Graduate School of Engineering, Kyoto University, 1-2 Yumihama, Otsu, Shiga 520-0811, Japan.
| | - Kyoungsoo Park
- Research Center for Environmental Quality Management, Graduate School of Engineering, Kyoto University, 1-2 Yumihama, Otsu, Shiga 520-0811, Japan
| | - Daisuke Kondo
- Research Center for Environmental Quality Management, Graduate School of Engineering, Kyoto University, 1-2 Yumihama, Otsu, Shiga 520-0811, Japan
| | - Hiroyuki Wada
- Research Center for Environmental Quality Management, Graduate School of Engineering, Kyoto University, 1-2 Yumihama, Otsu, Shiga 520-0811, Japan
| | - Norihide Nakada
- Research Center for Environmental Quality Management, Graduate School of Engineering, Kyoto University, 1-2 Yumihama, Otsu, Shiga 520-0811, Japan; Graduate School of Engineering, Kanagawa University, 3-27-1 Rokkakubashi, Yokohama, Kanagawa 221-8686, Japan
| | - Fumitake Nishimura
- Research Center for Environmental Quality Management, Graduate School of Engineering, Kyoto University, 1-2 Yumihama, Otsu, Shiga 520-0811, Japan
| | - Masaru Ihara
- Research Center for Environmental Quality Management, Graduate School of Engineering, Kyoto University, 1-2 Yumihama, Otsu, Shiga 520-0811, Japan; Faculty of Agriculture and Marine Science, Kochi University, 200 Monobe-Otsu, Nankoku city, Kochi 783-8502, Japan.
| | - Hiroaki Tanaka
- Research Center for Environmental Quality Management, Graduate School of Engineering, Kyoto University, 1-2 Yumihama, Otsu, Shiga 520-0811, Japan
| |
Collapse
|
5
|
Ni X, Hou X, Ma D, Li Q, Li L, Gao B, Wang Y. Simultaneous removal of antibiotics and antibiotic resistant genes using a CeO 2@CNT electrochemical membrane-NaClO system. CHEMOSPHERE 2023; 338:139457. [PMID: 37429382 DOI: 10.1016/j.chemosphere.2023.139457] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 07/07/2023] [Accepted: 07/08/2023] [Indexed: 07/12/2023]
Abstract
The simultaneous removal of antibiotic and antibiotic resistance genes (ARGs) are important to inhibit the spread of antibiotic resistance. In this study, a coupled treatment system was developed using a CeO2 modified carbon nanotube electrochemical membrane and NaClO (denoted as CeO2@CNT-NaClO) to treat simulated water samples containing antibiotics and antibiotic-resistant bacteria (ARB). As the mass ratio of CeO2 to CNT was 5:7 and the current density was 2.0 mA/cm2, the CeO2@CNT-NaClO system removed 99% of sulfamethoxazole, 4.6 log sul1 genes, and 4.7 log intI1 genes from the sulfonamide-resistance water samples, and removed 98% of tetracycline, 2.0 log tetA genes, and 2.6 log intI1 genes of the tetracycline-resistance water samples. The outstanding performance of the CeO2@CNT-NaClO system for simultaneously removing antibiotic and ARGs was mainly ascribed to the generation of multiple reactive species, including •OH, •ClO, •O2- and 1O2. Antibiotics can undergo efficient degradation by •OH. However, the reaction between •OH and antibiotics reduces the availability of •OH to permeate into the cells and react with DNA. Nevertheless, the presence of •OH enhancd the effects of •ClO, •O2-, and 1O on ARG degradation. Through the coupled action of •OH, •ClO, •O2-, and 1O2, the cell membranes of ARB experience severe damage, resulting in an increase in intracellular reactive oxygen species (ROS) and a decrease in superoxide dismutase (SOD) activity. Consequently, this coordinated mechanism leads to superior removal of ARGs.
Collapse
Affiliation(s)
- Xiaoyu Ni
- Shandong Key Laboratory of Water Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Shandong University, Qingdao, PR China
| | - Xuan Hou
- Shandong Key Laboratory of Water Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Shandong University, Qingdao, PR China
| | - Defang Ma
- Shandong Key Laboratory of Water Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Shandong University, Qingdao, PR China
| | - Qian Li
- Shandong Key Laboratory of Water Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Shandong University, Qingdao, PR China
| | - Ling Li
- State Key Lab of Microbial Technology, Microbial Technology Institute, Shandong University, Qingdao, PR China
| | - Baoyu Gao
- Shandong Key Laboratory of Water Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Shandong University, Qingdao, PR China
| | - Yan Wang
- Shandong Key Laboratory of Water Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Shandong University, Qingdao, PR China; The Key Lab of Eco-restoration of Regional Contaminated Environment, Shenyang University, Shenyang, PR China.
| |
Collapse
|
6
|
Poblete R, Bakit J. Technical and economical assessment of the treatment of vinasse from Pisco production using the advanced oxidation process. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2023:10.1007/s11356-023-27390-7. [PMID: 37145363 DOI: 10.1007/s11356-023-27390-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Accepted: 04/28/2023] [Indexed: 05/06/2023]
Abstract
The removal of organic matter from Pisco production wastewater was evaluated using coagulation/flocculation, filtration as a pre-treatment, and solar photo-Fenton, with the use of two types of photoreactors: compound parabolic collectors (CPC) and flat plate (FP), with and without utilizing the ozonation process. The overall removal efficiency for chemical oxygen demand (COD) was 63% and 15% using FP and CPC, respectively. Also, for the overall removal efficiency of polyphenols, a percentage of 73% and 43% were obtained using FP and CPC, respectively. When ozone was used in the solar photoreactors, the resulting trends were similar. COD and polyphenol removal, using an FP photoreactor in the solar photo-Fenton/O3 process, resulted in values of 98.8% and 86.2% after the process. COD and polyphenol removal, using solar photo-Fenton/O3 process in a CPC, resulted in values of 49.5% and 72.4%, respectively. The economic indicators of annual worth and economic treatment capacity established that FP reactors represent lower costs than CPCs. These results were corroborated by the economic analyses of the evolution of costs versus COD removed as well as by the cash flow diagrams projected for 5, 10, and 15 years.
Collapse
Affiliation(s)
- Rodrigo Poblete
- Universidad Católica del Norte, Facultad de Ciencias del Mar, Escuela de Prevención de Riesgos Y Medioambiente, Universidad Católica del Norte, Larrondo 1281, 1780000, Coquimbo, Chile.
| | - José Bakit
- Universidad Católica del Norte, Facultad de Ciencias del Mar, Departamento de Acuicultura, Universidad Católica del Norte, Larrondo 1281, 1780000, Coquimbo, Chile
| |
Collapse
|