1
|
Zhang L, Tan QG, Fan JQ, Sun C, Luo YT, Liang RP, Qiu JD. Microfluidics for chiral separation of biomolecules. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116842] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
2
|
Duca ZA, Speller NC, Cato ME, Morbioli GG, Stockton AM. A miniaturized, low-cost lens tube based laser-induced fluorescence detection system for automated microfluidic analysis of primary amines. Talanta 2022; 241:123227. [DOI: 10.1016/j.talanta.2022.123227] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 01/07/2022] [Accepted: 01/11/2022] [Indexed: 02/08/2023]
|
3
|
Chirality in Organic and Mineral Systems: A Review of Reactivity and Alteration Processes Relevant to Prebiotic Chemistry and Life Detection Missions. Symmetry (Basel) 2022. [DOI: 10.3390/sym14030460] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
Chirality is a central feature in the evolution of biological systems, but the reason for biology’s strong preference for specific chiralities of amino acids, sugars, and other molecules remains a controversial and unanswered question in origins of life research. Biological polymers tend toward homochiral systems, which favor the incorporation of a single enantiomer (molecules with a specific chiral configuration) over the other. There have been numerous investigations into the processes that preferentially enrich one enantiomer to understand the evolution of an early, racemic, prebiotic organic world. Chirality can also be a property of minerals; their interaction with chiral organics is important for assessing how post-depositional alteration processes could affect the stereochemical configuration of simple and complex organic molecules. In this paper, we review the properties of organic compounds and minerals as well as the physical, chemical, and geological processes that affect organic and mineral chirality during the preservation and detection of organic compounds. We provide perspectives and discussions on the reactions and analytical techniques that can be performed in the laboratory, and comment on the state of knowledge of flight-capable technologies in current and future planetary missions, with a focus on organics analysis and life detection.
Collapse
|
4
|
Twenty years of amino acid determination using capillary electrophoresis: A review. Anal Chim Acta 2021; 1174:338233. [DOI: 10.1016/j.aca.2021.338233] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 01/14/2021] [Accepted: 01/16/2021] [Indexed: 12/28/2022]
|
5
|
LC-MS/MS quantification of asymmetric dimethyl arginine and symmetric dimethyl arginine in plasma using surrogate matrix and derivatization with fluorescamine. Bioanalysis 2020; 12:1607-1619. [PMID: 33151745 DOI: 10.4155/bio-2020-0223] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Aim: A novel LC-MS/MS method using a surrogate matrix and derivatization with fluorescamine was developed and validated for simultaneous quantification of asymmetric dimethyl arginine and symmetric dimethyl arginine. Methods & results: Asymmetric dimethyl arginine, symmetric dimethyl arginine and corresponding internal standards were extracted using protein precipitation and derivatization with fluorescamine followed by SPE. Derivatives were analyzed by turbo ion spray LC-MS/MS in the positive ion mode. Methodology was successfully transferred across multiple preclinical species and utilized in the support of several investigative studies. Conclusion: A new LC-MS/MS analytical methodology that utilizes a surrogate matrix and derivatization with fluorescamine was successfully developed and validated.
Collapse
|
6
|
Zhang Y, Hu X, Wang Q, He P. Investigation of hydroxypropyl-β-cyclodextrin-based synergistic system with chiral nematic mesoporous silica as chiral stationary phase for enantiomeric separation in microchip electrophoresis. Talanta 2020; 218:121121. [DOI: 10.1016/j.talanta.2020.121121] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2019] [Revised: 04/29/2020] [Accepted: 05/03/2020] [Indexed: 10/24/2022]
|
7
|
Duca ZA, Speller NC, Cantrell T, Stockton AM. A modular, easy-to-use microcapillary electrophoresis system with laser-induced fluorescence for quantitative compositional analysis of trace organic molecules. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2020; 91:104101. [PMID: 33138565 DOI: 10.1063/5.0008734] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Accepted: 09/14/2020] [Indexed: 06/11/2023]
Abstract
Microcapillary electrophoresis (μCE) enables high-resolution separations in miniaturized, automated microfluidic devices. Pairing this powerful separation technique with laser-induced fluorescence (LIF) enables a highly sensitive, quantitative, and compositional analysis of organic molecule monomers and short polymers, which are essential, ubiquitous components of life on Earth. Improving methods for their detection has applications to multiple scientific fields, particularly those related to medicine, industry, and space science. Here, a modular benchtop system using μCE with LIF detection was constructed and tested by analyzing standard amino acid samples of valine, serine, alanine, glycine, glutamic acid, and aspartic acid in multiple borate buffered solutions of increasing concentrations from 10 mM to 50 mM, all pH 9.5. The 35 mM borate buffer solution generated the highest resolution before Joule heating dominated. The limits of detection of alanine and glycine using 35 mM borate buffer were found to be 2.12 nM and 2.91 nM, respectively, comparable to other state-of-the-art μCE-LIF instruments. This benchtop system is amenable to a variety of detectors, including a photomultiplier tube, a silicon photomultiplier, or a spectrometer, and currently employs a spectrometer for facile multi-wavelength detection. Furthermore, the microdevice is easily exchanged to fit the desired application of the system, and optical components within the central filter cube can be easily replaced to target alternative fluorescent dyes. This work represents a significant step forward for the analysis of small organic molecules and biopolymers using μCE-LIF systems.
Collapse
Affiliation(s)
- Zachary A Duca
- Georgia Institute of Technology, Atlanta, Georgia 30332, USA
| | | | - Thomas Cantrell
- Georgia Institute of Technology, Atlanta, Georgia 30332, USA
| | | |
Collapse
|
8
|
Creamer JS, Mora MF, Noell AC, Willis PA. Long-term thermal stability of fluorescent dye used for chiral amino acid analysis on future spaceflight missions. Electrophoresis 2019; 40:3117-3122. [PMID: 31599461 DOI: 10.1002/elps.201900268] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Revised: 09/24/2019] [Accepted: 09/25/2019] [Indexed: 11/11/2022]
Abstract
Future spaceflight missions focused on life detection will carry with them new, state-of-the-art instrumentation capable of highly selective and sensitive organic analysis. CE-LIF is an ideal candidate for such a mission due to its high separation efficiency and low LODs. One perceived risk of utilizing this technique on a future mission is the stability of the chemical reagents in the spaceflight environment. Here, we present an investigation of the thermal stability of the fluorescent dye (5-carboxyfluorescein succinimidyl ester) used for amino acid analysis. The dye was stored at 4, 25, and 60°C for 1 month, 6 months, 1 year, and 2 years. When stored at 4°C for 2 years, 25°C for 6 months, or 60°C for 1 month there was no effect on CE-LIF assay performance due to dye degradation. Beyond these time points, while the dye degradation begins to interfere with the analysis, it is still possible to perform the analysis and achieve the majority of amino acid biosignature science goals described in the science definition team report for the potential Europa Lander mission. This work indicates that thermal control of the dye at ≤4°C will be needed during transit on future spaceflight missions to maintain dye stability.
Collapse
Affiliation(s)
- Jessica S Creamer
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California
| | - Maria F Mora
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California
| | - Aaron C Noell
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California
| | - Peter A Willis
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California
| |
Collapse
|
9
|
7-(Diethylamino)coumarin-3-carboxylic acid as derivatization reagent for 405 nm laser-induced fluorescence detection: A case study for the analysis of sulfonamides by capillary electrophoresis. Talanta 2019; 201:16-22. [DOI: 10.1016/j.talanta.2019.03.093] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2018] [Revised: 03/16/2019] [Accepted: 03/27/2019] [Indexed: 01/12/2023]
|
10
|
Novel, efficient, facile, and comprehensive protocol for post-column amino acid analysis of icatibant acetate containing natural and unnatural amino acids using the QbD approach. Amino Acids 2018; 51:295-309. [DOI: 10.1007/s00726-018-2665-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2018] [Accepted: 10/10/2018] [Indexed: 02/06/2023]
|
11
|
Creamer JS, Mora MF, Willis PA. Enhanced Resolution of Chiral Amino Acids with Capillary Electrophoresis for Biosignature Detection in Extraterrestrial Samples. Anal Chem 2016; 89:1329-1337. [DOI: 10.1021/acs.analchem.6b04338] [Citation(s) in RCA: 78] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Jessica S. Creamer
- Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, California 91109, United States
| | - Maria F. Mora
- Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, California 91109, United States
| | - Peter A. Willis
- Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, California 91109, United States
| |
Collapse
|
12
|
Fang XX, Li HY, Fang P, Pan JZ, Fang Q. A handheld laser-induced fluorescence detector for multiple applications. Talanta 2015; 150:135-41. [PMID: 26838391 DOI: 10.1016/j.talanta.2015.12.018] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2015] [Revised: 12/02/2015] [Accepted: 12/10/2015] [Indexed: 10/22/2022]
Abstract
In this paper, we present a compact handheld laser-induced fluorescence (LIF) detector based on a 450 nm laser diode and quasi-confocal optical configuration with a total size of 9.1 × 6.2 × 4.1 cm(3). Since there are few reports on the use of 450 nm laser diode in LIF detection, especially in miniaturized LIF detector, we systematically investigated various optical arrangements suitable for the requirements of 450 nm laser diode and system miniaturization, including focusing lens, filter combination, and pinhole, as well as Raman effect of water at 450 nm excitation wavelength. As the result, the handheld LIF detector integrates the light source (450 nm laser diode), optical circuit module (including a 450 nm band-pass filter, a dichroic mirror, a collimating lens, a 525 nm band-pass filter, and a 1.0mm aperture), optical detector (miniaturized photomultiplier tube), as well as electronic module (including signal recording, processing and displaying units). This detector is capable of working independently with a cost of ca. $2000 for the whole instrument. The detection limit of the instrument for sodium fluorescein solution is 0.42 nM (S/N=3). The broad applicability of the present system was demonstrated in capillary electrophoresis separation of fluorescein isothiocyanate (FITC) labeled amino acids and in flow cytometry of tumor cells as an on-line LIF detector, as well as in droplet array chip analysis as a LIF scanner. We expect such a compact LIF detector could be applied in flow analysis systems as an on-line detector, and in field analysis and biosensor analysis as a portable universal LIF detector.
Collapse
Affiliation(s)
- Xiao-Xia Fang
- Institute of Microanalytical Systems, Department of Chemistry, Zhejiang University, Hangzhou 310058, China
| | - Han-Yang Li
- Institute of Microanalytical Systems, Department of Chemistry, Zhejiang University, Hangzhou 310058, China
| | - Pan Fang
- Institute of Microanalytical Systems, Department of Chemistry, Zhejiang University, Hangzhou 310058, China
| | - Jian-Zhang Pan
- Institute of Microanalytical Systems, Department of Chemistry, Zhejiang University, Hangzhou 310058, China.
| | - Qun Fang
- Institute of Microanalytical Systems, Department of Chemistry, Zhejiang University, Hangzhou 310058, China.
| |
Collapse
|
13
|
Willis PA, Creamer JS, Mora MF. Implementation of microchip electrophoresis instrumentation for future spaceflight missions. Anal Bioanal Chem 2015; 407:6939-63. [PMID: 26253225 DOI: 10.1007/s00216-015-8903-z] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2015] [Revised: 06/30/2015] [Accepted: 07/03/2015] [Indexed: 11/27/2022]
Abstract
We present a comprehensive discussion of the role that microchip electrophoresis (ME) instrumentation could play in future NASA missions of exploration, as well as the current barriers that must be overcome to make this type of chemical investigation possible. We describe how ME would be able to fill fundamental gaps in our knowledge of the potential for past, present, or future life beyond Earth. Despite the great promise of ME for ultrasensitive portable chemical analysis, to date, it has never been used on a robotic mission of exploration to another world. We provide a current snapshot of the technology readiness level (TRL) of ME instrumentation, where the TRL is the NASA systems engineering metric used to evaluate the maturity of technology, and its fitness for implementation on missions. We explain how the NASA flight implementation process would apply specifically to ME instrumentation, and outline the scientific and technology development issues that must be addressed for ME analyses to be performed successfully on another world. We also outline research demonstrations that could be accomplished by independent researchers to help advance the TRL of ME instrumentation for future exploration missions. The overall approach described here for system development could be readily applied to a wide range of other instrumentation development efforts having broad societal and commercial impact.
Collapse
Affiliation(s)
- Peter A Willis
- Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Dr., Pasadena, CA, 91109, USA,
| | | | | |
Collapse
|
14
|
Ferey L, Delaunay N. Capillary and microchip electrophoretic analysis of polycyclic aromatic hydrocarbons. Anal Bioanal Chem 2014; 407:2727-47. [PMID: 25542576 DOI: 10.1007/s00216-014-8390-7] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2014] [Revised: 11/24/2014] [Accepted: 12/03/2014] [Indexed: 12/18/2022]
Abstract
Polycyclic aromatic hydrocarbons (PAHs) are ubiquitous contaminants which can reach the environment and food in different ways. Because of their high toxicity, two international regulatory institutions, the US Environmental Protection Agency and the European Food Safety Authority, have classified PAHs as priority pollutants, generating an important demand for the detection and identification of PAHs. Thus, sensitive, fast, and cheap methods for the analysis of PAHs in environmental and food samples are urgently needed. Within this context, electrophoresis, in capillary or microchip format, displays attractive features. This review presents and critically discusses the published literature on the different approaches to capillary and microchip electrophoresis analysis of PAHs.
Collapse
Affiliation(s)
- Ludivine Ferey
- Laboratory of Analytical and Bioanalytical Sciences and Miniaturization, Chemistry, Biology, and Innovation (CBI), UMR 8231 CNRS - ESPCI ParisTech, PSL Research University, 75005, Paris, France
| | | |
Collapse
|
15
|
Szente L, Szemán J. Cyclodextrins in Analytical Chemistry: Host–Guest Type Molecular Recognition. Anal Chem 2013; 85:8024-30. [DOI: 10.1021/ac400639y] [Citation(s) in RCA: 192] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Lajos Szente
- CYCLOLAB, Cyclodextrin Research and Development Laboratory Ltd., H-1097 Budapest, Illatos út
7, Hungary
| | - Julianna Szemán
- CYCLOLAB, Cyclodextrin Research and Development Laboratory Ltd., H-1097 Budapest, Illatos út
7, Hungary
| |
Collapse
|
16
|
Nan H, Lee SW, Kang SH. Fast screening of rice knockout mutants by multi-channel microchip electrophoresis. Talanta 2012; 97:249-55. [DOI: 10.1016/j.talanta.2012.04.026] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2012] [Revised: 04/11/2012] [Accepted: 04/19/2012] [Indexed: 10/28/2022]
|
17
|
Huang Y, Shi M, Zhao S, Liang H. Trace analysis of d-tyrosine in biological samples by microchip electrophoresis with laser induced fluorescence detection. J Chromatogr B Analyt Technol Biomed Life Sci 2011; 879:3203-7. [DOI: 10.1016/j.jchromb.2011.01.033] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2010] [Revised: 01/23/2011] [Accepted: 01/27/2011] [Indexed: 01/09/2023]
|
18
|
Stockton AM, Tjin CC, Chiesl TN, Mathies RA. Analysis of carbonaceous biomarkers with the Mars Organic Analyzer microchip capillary electrophoresis system: carboxylic acids. ASTROBIOLOGY 2011; 11:519-528. [PMID: 21790324 DOI: 10.1089/ast.2011.0634] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
The oxidizing surface chemistry on Mars argues that any comprehensive search for organic compounds indicative of life requires methods to analyze higher oxidation states of carbon with very low limits of detection. To address this goal, microchip capillary electrophoresis (μCE) methods were developed for analysis of carboxylic acids with the Mars Organic Analyzer (MOA). Fluorescent derivatization was achieved by activation with the water soluble 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC) followed by reaction with Cascade Blue hydrazide in 30 mM borate, pH 3. A standard containing 12 carboxylic acids found in terrestrial life was successfully labeled and separated in 30 mM borate at pH 9.5, 20 °C by using the MOA CE system. Limits of detection were 5-10 nM for aliphatic monoacids, 20 nM for malic acid (diacid), and 230 nM for citric acid (triacid). Polyacid benzene derivatives containing 2, 3, 4, and 6 carboxyl groups were also analyzed. In particular, mellitic acid was successfully labeled and analyzed with a limit of detection of 300 nM (5 ppb). Analyses of carboxylic acids sampled from a lava tube cave and a hydrothermal area demonstrated the versatility and robustness of our method. This work establishes that the MOA can be used for sensitive analyses of a wide range of carboxylic acids in the search for extraterrestrial organic molecules.
Collapse
Affiliation(s)
- Amanda M Stockton
- Department of Chemistry, University of California, Berkeley, California 94720, USA
| | | | | | | |
Collapse
|
19
|
Nagl S, Schulze P, Ohla S, Beyreiss R, Gitlin L, Belder D. Microfluidic chips for chirality exploration. Anal Chem 2011; 83:3232-8. [DOI: 10.1021/ac200150w] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
|
20
|
Shukla A, Sanghi SK, Gowri VS, Baderia VK, Lamba S, Singh DK. Determination of biogenic amines in lake water by micellar electrokinetic chromatography with fluorescence detection after derivatization with fluorescamine. JOURNAL OF ANALYTICAL CHEMISTRY 2011. [DOI: 10.1134/s1061934811030038] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
21
|
Ross D, Shackman JG, Kralj JG, Atencia J. 2D separations on a 1D chip: gradient elution moving boundary electrophoresis-chiral capillary zone electrophoresis. LAB ON A CHIP 2010; 10:3139-3148. [PMID: 20886128 DOI: 10.1039/c004819d] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
A new method is described for two-dimensional (2D) separations using a microfluidic chip normally employed for single dimension electrophoresis. The method employs a combination of gradient elution moving boundary electrophoresis (GEMBE) and chiral capillary zone electrophoresis (CZE). The simplicity of the first dimension GEMBE method enables its implementation in the injection channel of a conventional electrophoresis chip, simplifying the design and operation of the device. The method was used for high resolution 2D chiral separations of a mixture of amino acids considered as possible signatures of extant or extinct life for solar system exploration. The enantiomers of aspartic acid, glutamic acid, serine, alanine, and valine were all resolved as well as glycine (achiral) and several unidentified impurities, giving an estimated peak capacity of 35 for the region between valine and glycine. The results highlight the need for high peak capacity separations for chiral amino acid analysis if accurate enantiomeric ratios are to be determined.
Collapse
Affiliation(s)
- David Ross
- National Institute of Standards and Technology, Gaithersburg, MD 20899, USA.
| | | | | | | |
Collapse
|
22
|
Stockton AM, Tjin CC, Huang GL, Benhabib M, Chiesl TN, Mathies RA. Analysis of carbonaceous biomarkers with the Mars Organic Analyzer microchip capillary electrophoresis system: aldehydes and ketones. Electrophoresis 2010; 31:3642-9. [PMID: 20967779 DOI: 10.1002/elps.201000424] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2010] [Revised: 08/18/2010] [Accepted: 08/19/2010] [Indexed: 11/11/2022]
Abstract
A microchip CE method is developed for the analysis of two oxidized forms of carbon, aldehydes and ketones, with the Mars Organic Analyzer (MOA). Fluorescent derivitization is achieved in ∼ 15 min by hydrazone formation with Cascade Blue hydrazide in 30 mM borate pH 5-6. The microchip CE separation and analysis method is optimized via separation in 30 mM borate buffer, pH 9.5, at 20°C. A carbonyl standard consisting of ten aldehydes and ketones found in extraterrestrial matter is successfully separated; the resulting LOD depends on the reactivity of the compound and range from 70 pM for formaldehyde to 2 μM for benzophenone. To explore the utility of this method for analyzing complex samples, analyses of several fermented beverages are conducted, identifying ten aldehydes and ketones ranging from 30 nM to 5 mM. A Martian regolith simulant sample, consisting of a basalt matrix spiked with soluble ions and acetone, is designed and analyzed, but acetone is found to have a limited detectable lifetime under simulant Martian conditions. This work establishes the capability of the MOA for studying aldehydes and ketones, a critical class of oxidized organic molecules of interest in planetary and in terrestrial environmental and health studies.
Collapse
Affiliation(s)
- Amanda M Stockton
- Department of Chemistry, University of California, Berkeley, CA 94720, USA
| | | | | | | | | | | |
Collapse
|
23
|
Nandi P, Desai DP, Lunte SM. Development of a PDMS-based microchip electrophoresis device for continuous online in vivo monitoring of microdialysis samples. Electrophoresis 2010; 31:1414-22. [PMID: 20358542 DOI: 10.1002/elps.200900612] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
A PDMS-based microfluidic system for online coupling of microdialysis sampling to microchip electrophoresis with fluorescence detection for in vivo analysis of amino acid neurotransmitters using naphthalene-2,3-dicarboxaldehyde and sodium cyanide as the derivatization reagents is described. Fabricating chips from PDMS rather than glass was found to be simpler and more reproducible, especially for chips with complex designs. The microchip incorporated a 20-cm serpentine channel in which sample plugs were introduced using a "simple" injection scheme; this made fluid handling and injection on-chip easier for the online system compared with gated or valve-based injection. The microchip was evaluated offline for the analysis of amino acid standards and rat brain microdialysis samples. Next, precolumn derivatization was incorporated into the chip and in vivo online microdialysis-microchip electrophoresis studies were performed. The system was employed for the continuous monitoring of amino acid neurotransmitters in the extracellular fluid of the brain of an anesthetized rat. Fluorescein was dosed intravenously and monitored simultaneously online as a marker of in vivo blood-brain barrier permeability. The microdialysis-microchip electrophoresis system described here will be employed in the future for simultaneous monitoring of changes in blood-brain barrier permeability and levels of amino acid neurotransmitters in the rat stroke model.
Collapse
Affiliation(s)
- Pradyot Nandi
- Department of Pharmaceutical Chemistry, University of Kansas, Lawrence, KS, USA
| | | | | |
Collapse
|
24
|
Gavina JMA, White CE, Finan TM, Britz-McKibbin P. Determination of 4-hydroxyproline-2-epimerase activity by capillary electrophoresis: A stereoselective platform for inhibitor screening of amino acid isomerases. Electrophoresis 2010; 31:2831-7. [DOI: 10.1002/elps.201000187] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
25
|
Danger G, Plasson R, Pascal R. An experimental investigation of the evolution of chirality in a potential dynamic peptide system: N-terminal epimerization and degradation into diketopiperazine. ASTROBIOLOGY 2010; 10:651-662. [PMID: 20735255 DOI: 10.1089/ast.2009.0450] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
The APED model (activation-polymerization-epimerization-depolymerization) is a unique example of a chemical system that allows symmetry breaking through a dynamic process involving indirect network autocatalysis. In its simplest version, the autocatalytic behavior of this model partly relies on the reproduction of local chiral centers in dipeptides through an epimerization process, with a thermodynamic preference for homochiral chains. We studied the reactivity of di- and tripeptides, containing a N-terminal phenylglycine (Phg) residue, as model compounds for the experimental determination of the kinetic and thermodynamic parameters related to the N-terminal epimerization process. Although the N-terminal residue is prone to spontaneous epimerization, catalysis was required for the epimerization to reach the equilibrium state in reasonable time. Unexpectedly, the observed equilibrium diastereoisomeric excesses have shown a general tendency for more stable heterochiral peptides, especially strong in the case of dipeptides. In parallel to this process, a stereoselective peptide cleavage through diketopiperazine formation was observed. Contrary to the N-terminal epimerization of peptides, the diketopiperazine formation did not need any catalyst, and heterochiral peptides were shown to be dynamically unstabilized, as they were cleaved faster than homochiral peptides. The validity of the extrapolation of these results to other residues and longer peptide chains is discussed, and some directions for future developments of the theoretical model are given.
Collapse
Affiliation(s)
- Grégoire Danger
- Institut des Biomolécules Max Mousseron, UMR 5247 CNRS, Université de Montpellier 1, Université de Montpellier 2, Montpellier, France.
| | | | | |
Collapse
|
26
|
Benhabib M, Chiesl TN, Stockton AM, Scherer JR, Mathies RA. Multichannel capillary electrophoresis microdevice and instrumentation for in situ planetary analysis of organic molecules and biomarkers. Anal Chem 2010; 82:2372-9. [PMID: 20151682 DOI: 10.1021/ac9025994] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The Multichannel Mars Organic Analyzer (McMOA), a portable instrument for the sensitive microchip capillary electrophoresis (CE) analysis of organic compounds such as amino acid biomarkers and polycyclic aromatic hydrocarbons (PAHs), is developed. The instrument uses a four-layer microchip, containing eight CE analysis systems integrated with a microfluidic network for autonomous fluidic processing. The McMOA has improved optical components that integrate 405 nm laser excitation with a linear-scanning optical system capable of multichannel real-time fluorescence spectroscopic analysis. The instrumental limit of detection is 6 pM (glycine). Microfluidic programs are executed to perform the automated sequential analysis of an amine-containing sample in each channel as well as eight consecutive analyses of alternating samples on the same channel, demonstrating less than 1% cross-contamination. The McMOA is used to identify the unique fluorescence spectra of nine components in a PAH standard and then applied to the analysis of a sediment sample from Lake Erie. The presence of benzo[a]pyrene and perylene in this sample is confirmed, and a peak coeluting with anthanthrene is disqualified based on spectral analysis. The McMOA exploits lab-on-a-chip technologies to fully integrate complex autonomous operations demonstrating the facile engineering of microchip-CE platforms for the analysis of a wide variety of organic compounds in planetary exploration.
Collapse
Affiliation(s)
- Merwan Benhabib
- Department of Chemistry, University of California at Berkeley, Berkeley, California 94720, USA
| | | | | | | | | |
Collapse
|
27
|
Trapp O. Investigation of the stereodynamics of molecules and catalyzed reactions by CE. Electrophoresis 2010; 31:786-813. [DOI: 10.1002/elps.200900599] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
28
|
Stockton AM, Chiesl TN, Lowenstein TK, Amashukeli X, Grunthaner F, Mathies RA. Capillary electrophoresis analysis of organic amines and amino acids in saline and acidic samples using the Mars organic analyzer. ASTROBIOLOGY 2009; 9:823-831. [PMID: 19968460 DOI: 10.1089/ast.2009.0357] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
The Mars Organic Analyzer (MOA) has enabled the sensitive detection of amino acid and amine biomarkers in laboratory standards and in a variety of field sample tests. However, the MOA is challenged when samples are extremely acidic and saline or contain polyvalent cations. Here, we have optimized the MOA analysis, sample labeling, and sample dilution buffers to handle such challenging samples more robustly. Higher ionic strength buffer systems with pK(a) values near pH 9 were developed to provide better buffering capacity and salt tolerance. The addition of ethylaminediaminetetraacetic acid (EDTA) ameliorates the negative effects of multivalent cations. The optimized protocol utilizes a 75 mM borate buffer (pH 9.5) for Pacific Blue labeling of amines and amino acids. After labeling, 50 mM (final concentration) EDTA is added to samples containing divalent cations to ameliorate their effects. This optimized protocol was used to successfully analyze amino acids in a saturated brine sample from Saline Valley, California, and a subcritical water extract of a highly acidic sample from the Río Tinto, Spain. This work expands the analytical capabilities of the MOA and increases its sensitivity and robustness for samples from extraterrestrial environments that may exhibit pH and salt extremes as well as metal ions.
Collapse
Affiliation(s)
- Amanda M Stockton
- Department of Chemistry, University of California, Berkeley, California 94720, USA
| | | | | | | | | | | |
Collapse
|
29
|
Abstract
This paper summarizes the history of chiral separations done by using electromigration methods with CDs. Several enantioresolution mechanisms and a wide number of chiral selectors have been applied to the separation of optical isomers by CE. Among them inclusion-complexation with CDs or their derivatives played a very important role in CE. Since the beginning our group was involved in studying method optimization for enantiomer resolution by using these chiral selectors. One of our publications was the basis for further development in the field, at least for us. New chiral selectors, development of theory, new methodological approaches and a wide number of practical applications are the main results achieved in the last almost 25 years using CE as an enantioseparative technique.
Collapse
Affiliation(s)
- Salvatore Fanali
- Institute of Chemical Methodologies, National Council of Research, Area della Ricerca di Roma I, Monterotondo Scalo (Rome), Italy.
| |
Collapse
|
30
|
Accessing reaction rate constants in on-column reaction chromatography: an extended unified equation for reaction educts and products with different response factors. Anal Bioanal Chem 2009; 395:1673-9. [DOI: 10.1007/s00216-009-2993-4] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2009] [Revised: 06/22/2009] [Accepted: 07/17/2009] [Indexed: 11/26/2022]
|
31
|
Nagl S, Schulze P, Ludwig M, Belder D. Progress in microchip enantioseparations. Electrophoresis 2009; 30:2765-72. [DOI: 10.1002/elps.200900153] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
32
|
Huang Y, Shi M, Zhao S. Quantification of D
-Asp and D
-Glu in rat brain and human cerebrospinal fluid by microchip electrophoresis. J Sep Sci 2009; 32:3001-6. [DOI: 10.1002/jssc.200900026] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
33
|
Gikas E, Parissi‐Poulou M, Kazanis M, Vavagianis A. MOZPhCSE, a New Coumarin Based Fluorescent Derivatization Reagent. J LIQ CHROMATOGR R T 2009. [DOI: 10.1081/jlc-200029226] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Affiliation(s)
- Evagelos Gikas
- a Division of Pharmaceutical Chemistry, Department of Pharmacy , University of Athens , Athens , Greece
- b GAIA Research Center, The Goulandris Natural History Museum , 13 Levidou Str., Kifissia , 14562 , Greece
| | - Maria Parissi‐Poulou
- a Division of Pharmaceutical Chemistry, Department of Pharmacy , University of Athens , Athens , Greece
| | - Michael Kazanis
- a Division of Pharmaceutical Chemistry, Department of Pharmacy , University of Athens , Athens , Greece
| | - Andreas Vavagianis
- a Division of Pharmaceutical Chemistry, Department of Pharmacy , University of Athens , Athens , Greece
| |
Collapse
|
34
|
Chiesl TN, Chu WK, Stockton AM, Amashukeli X, Grunthaner F, Mathies RA. Enhanced amine and amino acid analysis using Pacific Blue and the Mars Organic Analyzer microchip capillary electrophoresis system. Anal Chem 2009; 81:2537-44. [PMID: 19245228 DOI: 10.1021/ac8023334] [Citation(s) in RCA: 81] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The fluorescent amine reactive probe Pacific Blue succinimidyl ester (PB) is used for the detection of trace amounts of amines and amino acids by microchip capillary electrophoresis on the Mars Organic Analyzer (MOA). The spectral and chemical properties of PB provide a 200-fold increase in sensitivity and improved resolution compared to fluorescamine derivatization. With the use of cross injection and PB labeling, the MOA detected amino acids at concentrations as low as 75 pM (sub-parts-per-trillion). Micellar electrokinetic chromatography (MEKC) which separates PB-labeled amino acids by their hydrophobicity is also demonstrated. The optimized MEKC conditions (45 mM CHAPSO, pH 6 at 5 degrees C) effectively separated amines and 25 amino acids with enantiomeric resolution of alanine, serine, and citrulline. Samples from the Yungay Hills region in the Atacama Desert, Chile, and from the Murchison meteorite are successfully analyzed using both techniques, and amino acids are found in the parts-per-billion range. Abiotic amino acids such as beta-alanine and epsilon-aminocaprioc acid are detected along with several neutral and acidic amino acids in the Murchison sample. The Atacama Desert sample is found to contain homochiral L-alanine and L-serine indicating the presence of extant or recently extinct life.
Collapse
Affiliation(s)
- Thomas N Chiesl
- Department of Chemistry, University of California Berkeley, Berkeley, California 94720, USA
| | | | | | | | | | | |
Collapse
|
35
|
Domínguez-Vega E, Martínez-Girón AB, García-Ruiz C, Crego AL, Marina ML. Fast derivatization of the non-protein amino acid ornithine with FITC using an ultrasound probe prior to enantiomeric determination in food supplements by EKC. Electrophoresis 2009; 30:1037-45. [DOI: 10.1002/elps.200800358] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
36
|
Stockton AM, Chiesl TN, Scherer JR, Mathies RA. Polycyclic aromatic hydrocarbon analysis with the Mars organic analyzer microchip capillary electrophoresis system. Anal Chem 2009; 81:790-6. [PMID: 19072718 DOI: 10.1021/ac802033u] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The Mars Organic Analyzer (MOA), a portable microchip capillary electrophoresis (CE) instrument developed for sensitive amino acid analysis on Mars, is used to analyze laboratory standards and real-world samples for polycyclic aromatic hydrocarbons (PAHs). The microfabricated CE separation and analysis method for these hydrophobic analytes is optimized, resulting in a separation buffer consisting of 10 mM sulfobutylether-beta-cyclodextrin, 40 mM methyl-beta-cyclodextrin, 5 mM carbonate buffer at pH 10, 5 degrees C. A PAH standard consisting of seven PAHs found in extraterrestrial matter and two terrestrial PAHs is successfully baseline separated. Limits of detection for the components of the standard ranged from 2000 ppm to 6 ppb. Analysis of an environmental contamination standard from Lake Erie and of a hydrothermal vent chimney sample from the Guaymas Basin agreed with published composition. A Martian analogue sample from the Yungay Hills region of the Atacama Desert was analyzed and found to contain 9,10-diphenylanthracene, anthracene, anthanthrene, fluoranthene, perylene, and benzo[ghi]fluoranthene at ppm levels. This work establishes the viability of the MOA for detecting and analyzing PAHs in in situ planetary exploration.
Collapse
Affiliation(s)
- Amanda M Stockton
- Department of Chemistry, University of California, Berkeley, California 94720, USA
| | | | | | | |
Collapse
|
37
|
Bremer S, Trapp O. Investigation of the stereodynamics of tris-(α-diimine)-transition metal complexes by enantioselective dynamic MEKC. Electrophoresis 2009; 30:329-36. [DOI: 10.1002/elps.200800320] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
38
|
Danger G, Ross D. Chiral separation with gradient elution isotachophoresis for futurein situextraterrestrial analysis. Electrophoresis 2008; 29:4036-44. [DOI: 10.1002/elps.200700950] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
39
|
Juvancz Z, Kendrovics RB, Iványi R, Szente L. The role of cyclodextrins in chiral capillary electrophoresis. Electrophoresis 2008; 29:1701-12. [PMID: 18421743 DOI: 10.1002/elps.200700657] [Citation(s) in RCA: 107] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The members of the enantiomeric pairs frequently show rather different biological effects, so their chiral selective synthesis, pharmacological studies and analysis are necessary. CE has unique advantages in chiral analysis. The most frequently used chiral selectors are CDs in this field. This paper gives a short view on the advantages on CE in direct chiral separations, emphasizing the role of CDs. The reason for the broad selectivity spectra of CDs is discussed in detail. The physical background of chiral selective separations is briefly shown in CE. Their interaction mechanisms are shortly defined. The general trend of their use is statistically evaluated. Most frequently used CDs and CD derivatives are characterized. Advantages of ionizable CDs and single-isomer derivatives are shown. The general trend of their use is established.
Collapse
Affiliation(s)
- Zoltán Juvancz
- Department of Environmental Engineering, Budapest Tech. Polytechnical Institution, Budapest, Hungary.
| | | | | | | |
Collapse
|
40
|
Danger G, Ross D. Development of a temperature gradient focusing method for in situ extraterrestrial biomarker analysis. Electrophoresis 2008; 29:3107-14. [DOI: 10.1002/elps.200700778] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
41
|
|
42
|
Aubrey AD, Chalmers JH, Bada JL, Grunthaner FJ, Amashukeli X, Willis P, Skelley AM, Mathies RA, Quinn RC, Zent AP, Ehrenfreund P, Amundson R, Glavin DP, Botta O, Barron L, Blaney DL, Clark BC, Coleman M, Hofmann BA, Josset JL, Rettberg P, Ride S, Robert F, Sephton MA, Yen A. The Urey instrument: an advanced in situ organic and oxidant detector for Mars exploration. ASTROBIOLOGY 2008; 8:583-595. [PMID: 18680409 DOI: 10.1089/ast.2007.0169] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
The Urey organic and oxidant detector consists of a suite of instruments designed to search for several classes of organic molecules in the martian regolith and ascertain whether these compounds were produced by biotic or abiotic processes using chirality measurements. These experiments will also determine the chemical stability of organic molecules within the host regolith based on the presence and chemical reactivity of surface and atmospheric oxidants. Urey has been selected for the Pasteur payload on the European Space Agency's (ESA's) upcoming 2013 ExoMars rover mission. The diverse and effective capabilities of Urey make it an integral part of the payload and will help to achieve a large portion of the mission's primary scientific objective: "to search for signs of past and present life on Mars." This instrument is named in honor of Harold Urey for his seminal contributions to the fields of cosmochemistry and the origin of life.
Collapse
Affiliation(s)
- Andrew D Aubrey
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California 91109, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
43
|
Khurana TK, Santiago JG. Preconcentration, Separation, and Indirect Detection of Nonfluorescent Analytes Using Fluorescent Mobility Markers. Anal Chem 2007; 80:279-86. [DOI: 10.1021/ac701706h] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Tarun K. Khurana
- Department of Mechanical Engineering, Stanford University, Stanford, California 94305
| | - Juan G. Santiago
- Department of Mechanical Engineering, Stanford University, Stanford, California 94305
| |
Collapse
|
44
|
Jayarajah CN, Skelley AM, Fortner AD, Mathies RA. Analysis of Neuroactive Amines in Fermented Beverages Using a Portable Microchip Capillary Electrophoresis System. Anal Chem 2007; 79:8162-9. [PMID: 17892274 DOI: 10.1021/ac071306s] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A portable microfabricated capillary electrophoresis (CE) instrument is used for the determination of neurologically active biogenic amines, especially tyramine and histamine, in fermented beverages. The target molecules are labeled on their primary amino groups with fluorescamine in a 10-min reaction, and the samples analyzed directly, producing a detailed electropherogram in only 120 s on a microfabricated glass CE device containing 21.4-cm-long separation channels. Tyramine was found mainly in red wines at <1-3.4 mg/L, while the histamine content of these samples ranged from 1.8 to 19 mg/L. The highest levels of histamine (20-40 mg/L) were found in sake. The analysis of samples drawn from grape crush through malolactic fermentation in four varieties of zinfandel red wines revealed that histamine and tyramine are produced during yeast and malolactic fermentation, respectively. Following malolactic fermentation, the histamine content in these samples ranged from 3.3 to 30 mg/L, and the tyramine content ranged from 1.0 to 3.0 mg/L. This highly sensitive and rapid lab-on-a-chip analysis method establishes the feasibility of monitoring neurologically active amine content and potentially other chemically and allergenically important molecules in our food supply.
Collapse
|
45
|
Gas chromatographic high-throughput screening techniques in catalysis. J Chromatogr A 2007; 1184:160-90. [PMID: 18035362 DOI: 10.1016/j.chroma.2007.10.086] [Citation(s) in RCA: 71] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2007] [Revised: 10/09/2007] [Accepted: 10/29/2007] [Indexed: 11/23/2022]
Abstract
Discovering highly efficient catalysts is of great scientific and economical interest. Advances in high-throughput assays in combination with sophisticated analytical techniques have increased the rapidity with which catalysts can be identified and optimized. Understanding how kinetics in the mechanism of catalysis is controlled by structural parameters is essential for a directed design of catalysts. To identify such rate-controlling elementary steps and to develop and refine models, comprehensive experimental kinetic data of a broad variety of substrates are necessary. In the present article concepts of high-throughput screening techniques in catalysis using gas chromatography are reviewed in a survey covering the period from 1998 to 2007. To cover also the origins of concepts and groundbreaking experiments in this research area milestones going back to 1950 are also reviewed. The first part of the review will focus on off-line gas chromatographic analysis, the second part on on-line gas chromatographic analysis covering sequential, parallelized and high-throughput multiplexing gas chromatography. The third part presents recent advances in the integration of chemical transformation and analysis in gas chromatography. The present review article describes the state-of-the-art, scope and limitations, and applications of these different high-throughput screening approaches.
Collapse
|
46
|
Ciriacks Klinker C, Bowser MT. 4-Fluoro-7-nitro-2,1,3-benzoxadiazole as a Fluorogenic Labeling Reagent for the in Vivo Analysis of Amino Acid Neurotransmitters Using Online Microdialysis−Capillary Electrophoresis. Anal Chem 2007; 79:8747-54. [DOI: 10.1021/ac071433o] [Citation(s) in RCA: 71] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Affiliation(s)
- Chanda Ciriacks Klinker
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455
| | - Michael T. Bowser
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455
| |
Collapse
|
47
|
Skelley AM, Aubrey AD, Willis PA, Amashukeli X, Ehrenfreund P, Bada JL, Grunthaner FJ, Mathies RA. Organic amine biomarker detection in the Yungay region of the Atacama Desert with the Urey instrument. ACTA ACUST UNITED AC 2007. [DOI: 10.1029/2006jg000329] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Alison M. Skelley
- Department of Chemistry; University of California; Berkeley California USA
| | - Andrew D. Aubrey
- Scripps Institution of Oceanography; University of California at San Diego; La Jolla California USA
| | - Peter A. Willis
- Jet Propulsion Laboratory; California Institute of Technology; Pasadena California USA
| | - Xenia Amashukeli
- Jet Propulsion Laboratory; California Institute of Technology; Pasadena California USA
| | | | - Jeffrey L. Bada
- Scripps Institution of Oceanography; University of California at San Diego; La Jolla California USA
| | - Frank J. Grunthaner
- Jet Propulsion Laboratory; California Institute of Technology; Pasadena California USA
| | - Richard A. Mathies
- Department of Chemistry; University of California; Berkeley California USA
| |
Collapse
|
48
|
Abstract
Microfluidic devices have been widely used to derivatize, separate, and detect amino acids employing many different strategies. Virtually zero-dead volume interconnections and fast mass transfer in small volume microchannels enable dramatic increases in on-chip derivatization reaction speed, while only minute amounts of sample and reagent are needed. Due to short channel path, fast subsecond separations can be carried out. With sophisticated miniaturized detectors, the whole analytical process can be integrated on one platform. This article reviews developments of lab-on-chip technology in amino acid analysis, it shows important design features such as sample preconcentration, precolumn and postcolumn amino acid derivatization, and unlabeled and labeled amino acid detection with focus on advanced designs. The review also describes important biomedical and space exploration applications of amino acid analysis on microfluidic devices.
Collapse
Affiliation(s)
- Martin Pumera
- ICYS, National Institute for Materials Science, Tsukuba, Japan.
| |
Collapse
|
49
|
Vlčková M, Stettler AR, Schwarz MA. Microchip Affinity Capillary Electrophoresis: Applications and Recent Advances. J LIQ CHROMATOGR R T 2007. [DOI: 10.1080/10826070600574754] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Affiliation(s)
- Markéta Vlčková
- a Universität Basel, Departement Chemie , Basel, Switzerland
| | | | | |
Collapse
|
50
|
Trapp O. A dynamic molecular probe to investigate catalytic effects and Joule heating in enantioselective MEKC. Electrophoresis 2007; 28:691-6. [PMID: 17226759 DOI: 10.1002/elps.200600596] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Enantiomerization of ferroin [tris(1,10-phenanthroline)-iron(II)-complex] was investigated by enantioselective dynamic micellar EKC. The enantiomer separation was performed in an aqueous 50 mM sodium borate/sodium dihydrogenphosphate buffer at pH 8.0 in the presence of the chiral surfactant sodium cholate. The unified equation of dynamic chromatography was employed to determine reaction rate constants from the electropherograms featured with distinct plateau formation. Activation parameters DeltaH( not equal) = 124.0 +/- 0.5 kJ/mol and DeltaS( not equal) = 121 +/- 1 J.K(-1)mol(-1) were calculated from temperature-dependent measurements between 10.0 and 27.5 degrees C in 2.5 K steps. Considering the data obtained by polarimetry of enantiomeric pure ferroin in water, it was found that enantiomerization rate in the micelle is accelerated by a factor of 12. Because of the highly positive activation entropy DeltaS( not equal), ferroin was used as a temperature-sensitive dynamic molecular probe to determine temperature deviations caused by Joule heating.
Collapse
Affiliation(s)
- Oliver Trapp
- Max-Planck-Institut für Kohlenforschung, Mülheim an der Ruhr, Germany.
| |
Collapse
|