1
|
Boublík M, Riesová M, Dubský P, Gaš B. Enhancement of the conductivity detection signal in capillary electrophoresis systems using neutral cyclodextrins as sweeping agents. Electrophoresis 2018; 39:1390-1398. [DOI: 10.1002/elps.201800027] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2018] [Revised: 02/08/2018] [Accepted: 02/08/2018] [Indexed: 11/11/2022]
Affiliation(s)
- Milan Boublík
- Faculty of Science; Department of Physical and Macromolecular Chemistry; Charles University in Prague; Prague Czech Republic
| | - Martina Riesová
- Faculty of Science; Department of Physical and Macromolecular Chemistry; Charles University in Prague; Prague Czech Republic
| | - Pavel Dubský
- Faculty of Science; Department of Physical and Macromolecular Chemistry; Charles University in Prague; Prague Czech Republic
| | - Bohuslav Gaš
- Faculty of Science; Department of Physical and Macromolecular Chemistry; Charles University in Prague; Prague Czech Republic
| |
Collapse
|
2
|
Application of capillary electrophoresis with electrokinetic supercharging and sweeping for the on-line preconcentration of phenolic acids. Anal Bioanal Chem 2015; 407:7093-100. [DOI: 10.1007/s00216-015-8869-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2015] [Revised: 06/03/2015] [Accepted: 06/18/2015] [Indexed: 11/27/2022]
|
3
|
Progress in stacking techniques based on field amplification of capillary electrophoresis. Anal Bioanal Chem 2014; 406:6129-50. [DOI: 10.1007/s00216-014-8062-7] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2014] [Revised: 07/21/2014] [Accepted: 07/22/2014] [Indexed: 02/07/2023]
|
4
|
Sáiz J, Mai TD, Hauser PC, García-Ruiz C. Determination of nitrogen mustard degradation products in water samples using a portable capillary electrophoresis instrument. Electrophoresis 2013; 34:2078-84. [PMID: 23686627 DOI: 10.1002/elps.201300054] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2013] [Revised: 05/10/2013] [Accepted: 05/10/2013] [Indexed: 12/26/2022]
Abstract
In this work, a new purpose-made portable CE instrument with a contactless conductivity detector was used for the determination of degradation products of nitrogen mustards in different water samples. The capillary was coated with poly(1-vinylpyrrolidone-co-2-dimethylaminoethyl methacrylate) to avoid analyte-wall interactions. The coating procedure was studied to obtain the best repeatability of the migration time of the analytes. Four different coating procedures were compared; flushing the capillary with the copolymer at 100 psi for 2 min at 60°C provided the best RSD values (<4%). The analytical method was also optimized. The use of 20 mM of MES adjusted to pH 6.0 with His as running buffer allowed a good baseline separation of the three analytes in different water samples without matrix interferences. The method permitted the detection of the three degradation products down to 5 μM.
Collapse
Affiliation(s)
- Jorge Sáiz
- Department of Analytical Chemistry, Multipurpose Building of Chemistry, University of Alcalá, Alcalá de Henares, Madrid, Spain
| | | | | | | |
Collapse
|
5
|
da Costa ET, Neves CA, Hotta GM, Vidal DTR, Barros MF, Ayon AA, Garcia CD, do Lago CL. Unmanned platform for long-range remote analysis of volatile compounds in air samples. Electrophoresis 2012; 33:2650-9. [PMID: 22965708 DOI: 10.1002/elps.201200273] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
This paper describes a long-range remotely controlled CE system built on an all-terrain vehicle. A four-stroke engine and a set of 12-V batteries were used to provide power to a series of subsystems that include drivers, communication, computers, and a capillary electrophoresis module. This dedicated instrument allows air sampling using a polypropylene porous tube, coupled to a flow system that transports the sample to the inlet of a fused-silica capillary. A hybrid approach was used for the construction of the analytical subsystem combining a conventional fused-silica capillary (used for separation) and a laser machined microfluidic block, made of PMMA. A solid-state cooling approach was also integrated in the CE module to enable controlling the temperature and therefore increasing the useful range of the robot. Although ultimately intended for detection of chemical warfare agents, the proposed system was used to analyze a series of volatile organic acids. As such, the system allowed the separation and detection of formic, acetic, and propionic acids with signal-to-noise ratios of 414, 150, and 115, respectively, after sampling by only 30 s and performing an electrokinetic injection during 2.0 s at 1.0 kV.
Collapse
Affiliation(s)
- Eric T da Costa
- Departamento de Química Fundamental-Instituto de Química-Universidade de São Paulo, São Paulo - SP, Brazil
| | | | | | | | | | | | | | | |
Collapse
|
6
|
Kenyon SM, Weiss NG, Hayes MA. Using electrophoretic exclusion to manipulate small molecules and particles on a microdevice. Electrophoresis 2012; 33:1227-35. [PMID: 22589099 DOI: 10.1002/elps.201100622] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Electrophoretic exclusion, a novel separations technique that differentiates species in bulk solution using the opposing forces of electrophoretic velocity and hydrodynamic flow, has been adapted to a microscale device. Proof-of-principle experiments indicate that the device was able to exclude small particles (1 μm polystyrene microspheres) and fluorescent dye molecules (rhodamine 123) from the entrance of a channel. Additionally, differentiation of the rhodamine 123 and polystyrene spheres was demonstrated. The current studies focus on the direct observation of the electrophoretic exclusion behavior on a microchip.
Collapse
Affiliation(s)
- Stacy M Kenyon
- Department of Chemistry and Biochemistry, Arizona State University, Tempe, AZ 85287, USA
| | | | | |
Collapse
|
7
|
Zirconia coated stir bar sorptive extraction combined with large volume sample stacking capillary electrophoresis-indirect ultraviolet detection for the determination of chemical warfare agent degradation products in water samples. J Chromatogr A 2012; 1247:49-56. [DOI: 10.1016/j.chroma.2012.05.059] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2012] [Revised: 05/11/2012] [Accepted: 05/17/2012] [Indexed: 11/19/2022]
|
8
|
Review of recent developments of on-line sample stacking techniques and their application in capillary electrophoresis. OPEN CHEM 2012. [DOI: 10.2478/s11532-012-0007-4] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023] Open
Abstract
AbstractCapillary electrophoresis (CE) has become one of the most useful tools in separation science because of its high separation efficiency, low cost, versatility, ease of sample preparation and automation. However, some limitations of CE, such as poor concentration sensitivity due to its lower sample loading and shorter optical path length, limits its further applications in separation science. In order to solve this problem, various on-line sample preconcentration techniques such as transient isotachophoresis preconcentration, field-enhanced sample stacking, micelle to solvent stacking, micelle collapse, dynamic pH junction, sweeping, solid phase extraction, single drop microextraction and liquid phase microextraction have been combined with CE. Recent developments, applications and some variants together with different combinations of these techniques integrating in CE are reviewed here and our discussions will be confined to the past three years (2008–2011).
Collapse
|
9
|
Abstract
AbstractCapillary electrophoresis (CE) is an attractive technique in separation science because of its high separation performance, short analysis time and low cost. Electrochemical detection (EC) is a powerful tool for CE because of its high sensitivity. In this review, developments of CE-EC from 2008 to August, 2011 are reviewed. We choose papers of innovative and novel results to demonstrate the newest and most important progress in CE-EC.
Collapse
|
10
|
Kubáň P, Seiman A, Makarõtševa N, Vaher M, Kaljurand M. In situ determination of nerve agents in various matrices by portable capillary electropherograph with contactless conductivity detection. J Chromatogr A 2011; 1218:2618-25. [DOI: 10.1016/j.chroma.2011.03.006] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2011] [Revised: 03/03/2011] [Accepted: 03/07/2011] [Indexed: 11/29/2022]
|
11
|
Kubáň P, Seiman A, Kaljurand M. Improving precision of manual hydrodynamic injection in capillary electrophoresis with contactless conductivity detection. J Chromatogr A 2011; 1218:1273-80. [DOI: 10.1016/j.chroma.2010.12.107] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2010] [Revised: 12/20/2010] [Accepted: 12/24/2010] [Indexed: 11/16/2022]
|
12
|
Aleksenko SS, Gareil P, Timerbaev AR. Analysis of degradation products of chemical warfare agents using capillary electrophoresis. Analyst 2011; 136:4103-18. [DOI: 10.1039/c1an15440k] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
13
|
Malá Z, Gebauer P, Boček P. Contemporary sample stacking in analytical electrophoresis. Electrophoresis 2010; 32:116-26. [DOI: 10.1002/elps.201000327] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2010] [Revised: 08/09/2010] [Accepted: 08/09/2010] [Indexed: 12/31/2022]
|
14
|
Kubáň P, Hauser PC. Capacitively coupled contactless conductivity detection for microseparation techniques - recent developments. Electrophoresis 2010; 32:30-42. [DOI: 10.1002/elps.201000354] [Citation(s) in RCA: 121] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2010] [Revised: 08/12/2010] [Accepted: 08/13/2010] [Indexed: 11/09/2022]
|
15
|
Breadmore MC, Dawod M, Quirino JP. Recent advances in enhancing the sensitivity of electrophoresis and electrochromatography in capillaries and microchips (2008-2010). Electrophoresis 2010; 32:127-48. [PMID: 21171119 DOI: 10.1002/elps.201000412] [Citation(s) in RCA: 129] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2010] [Revised: 09/15/2010] [Accepted: 09/16/2010] [Indexed: 01/22/2023]
Abstract
Capillary electrophoresis has been alive for over two decades now; yet, its sensitivity is still regarded as being inferior to that of more traditional methods of separation such as HPLC. As such, it is unsurprising that overcoming this issue still generates much scientific interest. This review continues to update this series of reviews, first published in Electrophoresis in 2007, with an update published in 2009 and covers material published through to June 2010. It includes developments in the fields of stacking, covering all methods from field-amplified sample stacking and large volume sample stacking, through to ITP, dynamic pH junction and sweeping. Attention is also given to on-line or in-line extraction methods that have been used for electrophoresis.
Collapse
Affiliation(s)
- Michael C Breadmore
- Australian Centre for Research on Separation Science, School of Chemistry, University of Tasmania, Hobart, TAS, Australia.
| | | | | |
Collapse
|
16
|
Chen XJ, Yang FQ, Wang YT, Li SP. CE and CEC of nucleosides and nucleotides in food materials. Electrophoresis 2010; 31:2092-105. [PMID: 20593386 DOI: 10.1002/elps.201000048] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Dietary nucleosides and nucleotides play an important role in the maintenance of functions of bone marrow hematopoietic cells, intestinal mucosa, and brain. Therefore, analysis of those compounds in food is very important for improving and assuring food quality. This review summarized the application of CE and CEC in the analysis of nucleosides and nucleotides in food. The sample preparation and detection are also discussed.
Collapse
Affiliation(s)
- Xiao-Jia Chen
- Institute of Chinese Medical Sciences, University of Macau, Macao SAR, PR China
| | | | | | | |
Collapse
|
17
|
Xia Z, Gan T, Chen H, Lv R, Wei W, Yang F. A new open tubular capillary microextraction and sweeping for the analysis of super low concentration of hydrophobic compounds. J Sep Sci 2010; 33:3221-30. [DOI: 10.1002/jssc.201000282] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
18
|
Hou X, Deng D, Wu X, Lv Y, Zhang J. Simultaneous stacking of cationic and anionic compounds in single run capillary zone electrophoresis by two-end field amplified sample injection. J Chromatogr A 2010; 1217:5622-7. [DOI: 10.1016/j.chroma.2010.06.070] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2009] [Revised: 06/24/2010] [Accepted: 06/24/2010] [Indexed: 11/30/2022]
|
19
|
|