1
|
Sevgen S, Kara G, Kir AS, Şahin A, Boyaci E. A critical review of bioanalytical and clinical applications of solid phase microextraction. J Pharm Biomed Anal 2025; 252:116487. [PMID: 39378761 DOI: 10.1016/j.jpba.2024.116487] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2024] [Revised: 09/07/2024] [Accepted: 09/26/2024] [Indexed: 10/10/2024]
Abstract
Studying the functions, mechanisms, and effects of drugs and other exogenous compounds on biological systems, together with investigations performed to understand biosystems better, comprises one of the most fascinating areas of research. Although classical sample preparation techniques are dominantly used to infer the relevant information from the investigated system, they fail to meet various imperative requirements, such as being environmentally friendly, applicable in-vivo, and compatible with online analysis. As a chameleon in the analytical toolbox, solid phase microextraction (SPME) is one of the best tools available for studying biological systems in unconventional ways. In this review, SPME is spotlighted, and its capability for bioanalytical applications, including drug analysis, untargeted and targeted metabolomics, in-vivo and clinical studies, is scrutinized based on studies reported in the past five years. In addition, novel extractive phases and instrumental coupling strategies developed to serve bioanalytical research are discussed to give the perspective for state-of-the-art and future developments. The literature assessment showed that SPME could act as a critical tool to investigate in-vivo biological systems and provide information about the elusive portion of the metabolome. Moreover, recently introduced miniaturized SPME probes further improved the low-invasive nature of the sampling and enabled sampling even from a single cell. The coupling of SPME directly to mass spectrometry significantly reduced the total analytical workflow and became one of the promising tools suitable for fast diagnostic purposes and drug analysis. The numerous applications and advancements reported in bioanalysis using SPME show that it will continue to be an indispensable technique in the future.
Collapse
Affiliation(s)
- Sılanur Sevgen
- Department of Chemistry, Middle East Technical University, Ankara 06800, Türkiye
| | - Gökşin Kara
- Department of Chemistry, Middle East Technical University, Ankara 06800, Türkiye
| | - Aysegul Seyma Kir
- Department of Chemistry, Middle East Technical University, Ankara 06800, Türkiye
| | - Alper Şahin
- Department of Chemistry, Middle East Technical University, Ankara 06800, Türkiye
| | - Ezel Boyaci
- Department of Chemistry, Middle East Technical University, Ankara 06800, Türkiye.
| |
Collapse
|
2
|
Li H, Tu Y, Xie W, Shi X, Zhang Q, Lin J, Zhong Y, Lin Z, Cai Z. In situ fabrication of covalent organic frameworks on solid-phase microextraction probes coupled with electrospray ionization mass spectrometry for enrichment and determination of androgens in biosamples. Mikrochim Acta 2024; 191:276. [PMID: 38644435 DOI: 10.1007/s00604-024-06355-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Accepted: 04/05/2024] [Indexed: 04/23/2024]
Abstract
Solid-phase microextraction (SPME) coupled with electrospray ionization mass spectrometry (ESI-MS) was developed for rapid and sensitive determination of endogenous androgens. The SPME probe is coated with covalent organic frameworks (COFs) synthesized by reacting 1,3,5-tri(4-aminophenyl)benzene (TPB) with 2,5-dioctyloxybenzaldehyde (C8PDA). This COFs-SPME probe offers several advantages, including enhanced extraction efficiency and stability. The analytical method exhibited wide linearity (0.1-100.0 µg L-1), low limits of detection (0.03-0.07 µg L-1), high enrichment factors (37-154), and satisfactory relative standard deviations (RSDs) for both within one probe (4.0-14.8%) and between different probes (3.4-12.7%). These remarkable performance characteristics highlight the reliability and precision of the COFs-SPME-ESI-MS method. The developed method was successfully applied to detect five kinds of endogenous androgens in female serum samples, indicating that the developed analytical method has great potential for application in preliminary clinical diagnosis.
Collapse
Affiliation(s)
- Heming Li
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, 2 Xueyuan Road, Qishan Campus, Fuzhou, 350108, Fujian, China
| | - Yuxin Tu
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, 2 Xueyuan Road, Qishan Campus, Fuzhou, 350108, Fujian, China
| | - Wen Xie
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, 2 Xueyuan Road, Qishan Campus, Fuzhou, 350108, Fujian, China
| | - Xinye Shi
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, 2 Xueyuan Road, Qishan Campus, Fuzhou, 350108, Fujian, China
| | - Qiuting Zhang
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, 2 Xueyuan Road, Qishan Campus, Fuzhou, 350108, Fujian, China
| | - Juan Lin
- Department of Cardiology, Fujian Provincial Governmental Hospital, Fuzhou, 350003, China
| | - Yanhui Zhong
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, 2 Xueyuan Road, Qishan Campus, Fuzhou, 350108, Fujian, China
| | - Zian Lin
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, 2 Xueyuan Road, Qishan Campus, Fuzhou, 350108, Fujian, China.
| | - Zongwei Cai
- State Key Laboratory of Environmental and Biological Analysis, Department of Chemistry, Hong Kong Baptist University, 224 Waterloo Road, Kowloon Tong, Hong Kong, SAR, People's Republic of China.
| |
Collapse
|
3
|
Godage N, Qian SS, Cudjoe E, Gionfriddo E. Enhancing Quantitative Analysis of Xenobiotics in Blood Plasma through Cross-Matrix Calibration and Bayesian Hierarchical Modeling. ACS MEASUREMENT SCIENCE AU 2024; 4:127-135. [PMID: 38404495 PMCID: PMC10885322 DOI: 10.1021/acsmeasuresciau.3c00049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Revised: 11/18/2023] [Accepted: 11/20/2023] [Indexed: 02/27/2024]
Abstract
This study addresses the challenges of matrix effects and interspecies plasma protein binding (PPB) on measurement variability during method validation across diverse plasma types (human, rat, rabbit, and bovine). Accurate measurements of small molecules in plasma samples often require matrix-matched calibration approaches with the use of specific plasma types, which may have limited availability or affordability. To mitigate the costs associated with human plasma measurements, we explore in this work the potential of cross-matrix-matched calibration using Bayesian hierarchical modeling (BHM) to correct for matrix effects associated with PPB. We initially developed a targeted quantitative approach utilizing biocompatible solid-phase microextraction coupled with liquid chromatography-mass spectrometry for xenobiotic analysis in plasma. The method was evaluated for absolute matrix effects across human, bovine, rat, and rabbit plasma comparing pre- and postmatrix extraction standards. Absolute matrix effects from 96 to 108% for most analytes across plasma sources indicate that the biocompatibility of the extraction phase minimizes interference coextraction. However, the extent of PPB in different media can still affect the accuracy of the measurement when the extraction of small molecules is carried out via free concentration, as in the case of microextraction techniques. In fact, while matrix-matched calibration revealed high accuracy, cross-matrix calibration (e.g., using a calibration curve generated from bovine plasma) proved inadequate for precise measurements in human plasma. A BHM was used to calculate correction factors for each analyte within each plasma type, successfully mitigating the measurement bias resulting from diverse calibration curve types used to quantify human plasma samples. This work contributes to the development of cost-effective, efficient calibration strategies for biofluids. Leveraging easily accessible plasma sources, like bovine plasma, for method optimization and validation prior to analyzing costly plasma (e.g., human plasma) holds substantial advantages applicable to biomonitoring and pharmacokinetic studies.
Collapse
Affiliation(s)
- Nipunika
H. Godage
- Department
of Chemistry and Biochemistry, College of Natural Sciences and Mathematics, The University of Toledo, Toledo, Ohio 43606, United States
- School
of Green Chemistry and Engineering, The
University of Toledo, Toledo, Ohio 43606, United States
- Dr.
Nina McClelland Laboratory for Water Chemistry and Environmental Analysis, The University of Toledo, Toledo, Ohio 43606, United States
| | - Song S. Qian
- Department
of Environmental Sciences, The University
of Toledo, Toledo, Ohio 43606, United States
| | | | - Emanuela Gionfriddo
- Department
of Chemistry and Biochemistry, College of Natural Sciences and Mathematics, The University of Toledo, Toledo, Ohio 43606, United States
- School
of Green Chemistry and Engineering, The
University of Toledo, Toledo, Ohio 43606, United States
- Dr.
Nina McClelland Laboratory for Water Chemistry and Environmental Analysis, The University of Toledo, Toledo, Ohio 43606, United States
| |
Collapse
|
4
|
Looby N, Roszkowska A, Yu M, Rios-Gomez G, Pipkin M, Bojko B, Cypel M, Pawliszyn J. In vivo solid phase microextraction for therapeutic monitoring and pharmacometabolomic fingerprinting of lung during in vivo lung perfusion of FOLFOX. J Pharm Anal 2023; 13:1195-1204. [PMID: 38024854 PMCID: PMC10657970 DOI: 10.1016/j.jpha.2023.04.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2022] [Revised: 04/04/2023] [Accepted: 04/08/2023] [Indexed: 12/01/2023] Open
Abstract
In vivo lung perfusion (IVLP) is a novel isolated lung technique developed to enable the local, in situ administration of high-dose chemotherapy to treat metastatic lung cancer. Combination therapy using folinic acid (FOL), 5-fluorouracil (F), and oxaliplatin (OX) (FOLFOX) is routinely employed to treat several types of solid tumours in various tissues. However, F is characterized by large interpatient variability with respect to plasma concentration, which necessitates close monitoring during treatments using of this compound. Since plasma drug concentrations often do not reflect tissue drug concentrations, it is essential to utilize sample-preparation methods specifically suited to monitoring drug levels in target organs. In this work, in vivo solid-phase microextraction (in vivo SPME) is proposed as an effective tool for quantitative therapeutic drug monitoring of FOLFOX in porcine lungs during pre-clinical IVLP and intravenous (IV) trials. The concomitant extraction of other endogenous and exogenous small molecules from the lung and their detection via liquid chromatography coupled to high resolution mass spectrometry (LC-HRMS) enabled an assessment of FOLFOX's impact on the metabolomic profile of the lung and revealed the metabolic pathways associated with the route of administration (IVLP vs. IV) and the therapy itself. This study also shows that the immediate instrumental analysis of metabolomic samples is ideal, as long-term storage at -80 °C results in changes in the metabolite content in the sample extracts.
Collapse
Affiliation(s)
- Nikita Looby
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| | - Anna Roszkowska
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
- Department of Pharmaceutical Chemistry, Medical University of Gdansk, 80-416, Gdansk, Poland
| | - Miao Yu
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| | - German Rios-Gomez
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| | - Mauricio Pipkin
- Division of Thoracic Surgery, University Health Network, TGH, 200 Elizabeth St, Toronto, ON, M5G 2C4, Canada
| | - Barbara Bojko
- Department of Pharmacodynamics and Molecular Pharmacology, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Torun, 85-089, Bydgoszcz, Poland
| | - Marcelo Cypel
- Division of Thoracic Surgery, University Health Network, TGH, 200 Elizabeth St, Toronto, ON, M5G 2C4, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| |
Collapse
|
5
|
Schneider A, Lima Feltraco Lizot LD, Reginatto GC, Hahn RZ, Bastiani MF, Bondan AP, Perassolo MS, Linden R. Determination of amphetamines, opioids, cocaine metabolites and 11-nor-9-carboxy-Δ9-tetrahydrocannabinol in urine using biocompatible solid-phase microextraction and ultra-performance LC-MS/MS. Bioanalysis 2023; 15:905-914. [PMID: 37354101 DOI: 10.4155/bio-2023-0094] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/26/2023] Open
Abstract
Background: Workplace drug testing primarily relies on urine analysis, targeting multiple compounds with varying physicochemical characteristics. Biocompatible solid-phase microextraction (BioSPME) is a miniaturized solid-phase extraction technique that enables the simultaneous extraction and preconcentration of analytes directly from the biological matrix. Methods: The BioSPME procedure consisted of the sequential extraction of 50-μl urine samples using LC Tips C18 in basic and acidic pH, followed by desorption with methanol and n-hexane, respectively. The extracts were analyzed by ultra-performance LC-MS/MS. Results: Intra-day precision was 1.2-8.6% and inter-day precision was 1.8-14.2%. Accuracy was 96.8-107.4%. The extraction yields were 62.8-109.4%. The matrix effects were -3.98% to 1%. Conclusion: BioSPME shows promise as an alternative method for preparing urine samples prior to drug measurement by ultra-performance LC-MS/MS.
Collapse
Affiliation(s)
- Anelise Schneider
- Laboratory of Analytical Toxicology, Feevale University, Novo Hamburgo, Brazil
| | | | | | - Roberta Zilles Hahn
- Laboratory of Analytical Toxicology, Feevale University, Novo Hamburgo, Brazil
| | - Marcos F Bastiani
- Laboratory of Analytical Toxicology, Feevale University, Novo Hamburgo, Brazil
| | | | | | - Rafael Linden
- Laboratory of Analytical Toxicology, Feevale University, Novo Hamburgo, Brazil
| |
Collapse
|
6
|
Yuan J, Huang W, Tong W, Chen Z, Li H, Chen J, Lin Z. In-situ growth of covalent organic framework on stainless steel needles as solid-phase microextraction probe coupled with electrospray ionization mass spectrometry for rapid and sensitive determination of tricyclic antidepressants in biosamples. J Chromatogr A 2023; 1695:463955. [PMID: 37004299 DOI: 10.1016/j.chroma.2023.463955] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Revised: 03/22/2023] [Accepted: 03/27/2023] [Indexed: 03/30/2023]
Abstract
Tricyclic antidepressants (TCAs) including amitriptyline (AT), doxepin (DOX) and nortriptyline (NT) are the first-line drugs for the clinical treatment of depression; however, monitoring TCA concentrations in biological fluids and tissues is necessary to improve therapeutic effect and determine the cause of death in patients. It is of great significance to develop a rapid and sensitive method for real-time monitoring of TCAs in various biosamples. In this work, we fabricated a novel covalent organic framework (COF) based solid-phase microextraction (SPME) probe by an in-situ step-by-step strategy, which was obtained by sequentially modifying 1,3,5-tri (4-aminophenyl) benzene (TPB) and 2, 5-divinylbenzaldehyde (DVA) on the surface of polydopamine layer. The TPB-DVA-COF-SPME probe possessed high specific surface area (1244 m2·g - 1), regular pores (3.23 nm), good hydrophobicity and stability, resulting in efficient enrichment for TCAs. Furthermore, the combination of TPB-DVA-COF-SPME probe and ambient electrospray ionization mass spectrometry system (ESI/MS) was firstly proposed for rapid and sensitive determination of TCAs in biosamples. As a result, the developed method exhibited low limits of detection (LODs) (0.1-0.5 μg∙L - 1), high enrichment factors (39-218), and low relative standard deviations (RSDs) for one probe (1.2-3.8%) and probe-to-probe (2.0-3.7%). Benefiting from these outstanding performance, TPB-DVA-COF-SPME probe was further successfully applied to biosamples (i.e., serum, liver, kidney, and brain) with excellent reusability, indicating the promising applicability of the TPB-DVA-COF-SPME-ESI/MS as a powerful tool for drug monitoring.
Collapse
Affiliation(s)
- Jiahao Yuan
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China
| | - Weini Huang
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China
| | - Wei Tong
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China
| | - Zihan Chen
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China
| | - Heming Li
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China
| | - Jiajing Chen
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China
| | - Zian Lin
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China.
| |
Collapse
|
7
|
Ullah N, Tuzen M. A New Trend and Future Perspectives of the Miniaturization of Conventional Extraction Methods for Elemental Analysis in Different Real Samples: A Review. Crit Rev Anal Chem 2022; 54:1729-1747. [PMID: 36197714 DOI: 10.1080/10408347.2022.2128635] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/10/2022]
Abstract
Sample preparation is one of the viable procedures to be used before analysis to enhance sensitivity and reduce the matrix effect. The current review is mainly emphasized the latest outcome and applications of microextraction techniques based on the miniaturization of the classical conventional methods based on liquid-phase and solid-phase extraction for the quantitative elemental analysis in different real samples. The limitation of the conventional sample preparation methods (liquid and solid phase extraction) has been overcome by developing a new way of reducing size as compared with the conventional system through the miniaturization approach. Miniaturization of the sample preparation techniques has received extensive attention due to its extraction at microlevels, speedy, economical, eco-friendly, and high extraction capability. The growing demand for speedy, economically feasible, and environmentally sound analytical approaches is the main intention to upgrade the conventional procedures apply for sample preparation in environmental investigation. A growing trend of research has been perceived to quantify the trace for elemental analysis in different natures of real samples. This review also recapitulates the current futuristic scenarios for the green and economically viable procedure with special overemphasis and concentrates on eco-friendly miniaturized sample-preparation techniques such as liquid-phase microextraction (LPME) and solid-phase microextraction (SPME). This review also emphasizes the latest progress and applications of the LPME and SPME approach and their future perspective.
Collapse
Affiliation(s)
- Naeem Ullah
- Faculty of Science and Arts, Chemistry Department, Tokat Gaziosmanpaşa University, Tokat, Turkey
- Department of Chemistry, University of Turbat, Balochistan, Pakistan
| | - Mustafa Tuzen
- Faculty of Science and Arts, Chemistry Department, Tokat Gaziosmanpaşa University, Tokat, Turkey
- Research Institute, Center for Environment and Marine Studies, King Fahd University of Petroleum and Minerals, Dhahran, Saudi Arabia
| |
Collapse
|
8
|
Godage NH, Gionfriddo E. Biocompatible SPME coupled to GC/MS for analysis of xenobiotics in blood plasma. J Chromatogr B Analyt Technol Biomed Life Sci 2022; 1203:123308. [DOI: 10.1016/j.jchromb.2022.123308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Revised: 05/11/2022] [Accepted: 05/16/2022] [Indexed: 10/18/2022]
|
9
|
Yu M, Roszkowska A, Pawliszyn J. In Vivo Solid-Phase Microextraction and Applications in Environmental Sciences. ACS ENVIRONMENTAL AU 2022; 2:30-41. [PMID: 37101756 PMCID: PMC10114724 DOI: 10.1021/acsenvironau.1c00024] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Solid-phase microextraction (SPME) is a well-established sample-preparation technique for environmental studies. The application of SPME has extended from the headspace extraction of volatile compounds to the capture of active components in living organisms via the direct immersion of SPME probes into the tissue (in vivo SPME). The development of biocompatible coatings and the availability of different calibration approaches enable the in vivo sampling of exogenous and endogenous compounds from the living plants and animals without the need for tissue collection. In addition, new geometries such as thin-film coatings, needle-trap devices, recession needles, coated tips, and blades have increased the sensitivity and robustness of in vivo sampling. In this paper, we detail the fundamentals of in vivo SPME, including the various extraction modes, coating geometries, calibration methods, and data analysis methods that are commonly employed. We also discuss recent applications of in vivo SPME in environmental studies and in the analysis of pollutants in plant and animal tissues, as well as in human saliva, breath, and skin analysis. As we show, in vivo SPME has tremendous potential for the targeted and untargeted screening of small molecules in living organisms for environmental monitoring applications.
Collapse
Affiliation(s)
- Miao Yu
- Department of Environmental Medicine and Public Health, Icahn School of Medicine at Mount Sinai, New York, New York 10029, United States
| | - Anna Roszkowska
- Department of Pharmaceutical Chemistry, Medical University of Gdansk, Gdansk 80-416, Poland
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| |
Collapse
|
10
|
Evaluation of New, Sputtered Carbon SPME Fibers with a Multi-Functional Group Test Mixture. SEPARATIONS 2021. [DOI: 10.3390/separations8120228] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
We report the first fabrication of sputtered carbon, solid-phase microextraction (SPME) fibers. These fibers have competitive extraction capabilities compared with the commercial carbon wide range (CWR) SPME fiber. This report also includes a demonstration of a newly developed SPME test mix that includes 15 different compounds with a wide range of functional groups and chemical properties. The fiber fabrication process involves sputtering carbon onto fused silica fibers, and the effects of throw distance on the morphology of the carbon coatings were studied. Four different carbon coating thicknesses were evaluated, with PDMS added as a stationary phase. These fibers were characterized with multiple analytical techniques, including scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), water contact angle (WCA) goniometry, as well as headspace (HS) and direct immersion (DI)–SPME–GC–MS. The best (11.5 µm) sputtered carbon SPME fibers, with and without PDMS, were evaluated using the new evaluation mix and compared with the commercial CWR fiber and a previously sputtered/developed silicon fiber. The new probe mix helped elucidate differences among the fibers, which would have been missed by current commercial test mixes. The sputtered carbon SPME fibers showed similar functional group selectivity as commercial CWR fibers. However, the sputtered carbon fibers showed higher responses per volume compared with the commercial CWR fiber, indicating the porous morphology of the sputtered carbon has the ability to overcome large phase thickness/volume discrepancies and increase the relative recovery for various compounds.
Collapse
|
11
|
|
12
|
Fishing of α-Glucosidase's Ligands from Aloe vera by α-Glucosidase Functionalized Magnetic Nanoparticles. Molecules 2021; 26:molecules26195840. [PMID: 34641385 PMCID: PMC8510290 DOI: 10.3390/molecules26195840] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2021] [Revised: 09/22/2021] [Accepted: 09/24/2021] [Indexed: 11/16/2022] Open
Abstract
α-Glucosidase was immobilized on magnetic nanoparticles (MNPs) for selective solid-phase extraction of the enzyme’s ligands present in Aloe vera, which is a medicinal plant used for the treatment of various diseases and possesses anti-diabetic activity. One new compound, aloeacone (2), together with two known compounds, aloenin aglycone (1) and aloin A (3), were fished out as the enzyme’s ligands. The structure of 2 was determined by HR-MS and comprehensive NMR techniques. Compound 3 exhibited a weak inhibitory effect on α-glucosidase, while compounds 1 and 2 were found to possess activation effects on the enzyme for the first time. It is interesting that both an inhibitor and agonists of α-glucosidase were fished out in one experiment.
Collapse
|
13
|
Roy KS, Nazdrajić E, Shimelis OI, Ross MJ, Chen Y, Cramer H, Pawliszyn J. Optimizing a High-Throughput Solid-Phase Microextraction System to Determine the Plasma Protein Binding of Drugs in Human Plasma. Anal Chem 2021; 93:11061-11065. [PMID: 34353028 DOI: 10.1021/acs.analchem.1c01986] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Plasma protein binding refers to the binding of a drug to plasma proteins after entering the body. The measurement of plasma protein binding is essential during drug development and in clinical practice, as it provides a more detailed understanding of the available free concentration of a drug in the blood, which is in turn critical for pharmacokinetics and pharmacodynamics studies. In addition, the accurate determination of the free concentration of a drug in the blood is also highly important for therapeutic drug monitoring and in personalized medicine. The present study uses C18-coated solid-phase microextraction 96-pin devices to determine the free concentrations of a set of drugs in plasma, as well as the plasma protein binding of drugs with a wide range of physicochemical properties. It should be noted that the extracted amounts used to calculate the binding constants and plasma protein bindings should be measured at respective equilibrium for plasma and phosphate buffer. Therefore, special attention is placed on properly determining the equilibration times required to correctly estimate the free concentrations of drugs in the investigated systems. The plasma protein binding values obtained with the 96-pin devices are consistent with those reported in the literature. The 96-pin device used in this research can be easily coupled with a Concept96 or other automated robotic systems to create an automated plasma protein binding determination protocol that is both more time and labor efficient compared to conventional equilibrium dialysis and ultrafiltration methods.
Collapse
Affiliation(s)
- Kanchan Sinha Roy
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| | - Emir Nazdrajić
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| | - Olga I Shimelis
- MilliporeSigma, 595 N. Harrison Road, Bellefonte, Pennsylvania 16823, United States
| | - M James Ross
- MilliporeSigma, 595 N. Harrison Road, Bellefonte, Pennsylvania 16823, United States
| | - Yong Chen
- MilliporeSigma, 595 N. Harrison Road, Bellefonte, Pennsylvania 16823, United States
| | - Hugh Cramer
- MilliporeSigma, 595 N. Harrison Road, Bellefonte, Pennsylvania 16823, United States
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
14
|
Methods of Lipidomic Analysis: Extraction, Derivatization, Separation, and Identification of Lipids. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2021. [PMID: 33791982 DOI: 10.1007/978-3-030-51652-9_12] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register]
Abstract
Lipidomics refers to the large-scale study of pathways and networks of cellular lipids in biological systems. A lipidomic analysis often involves the identification and quantification of the thousands of cellular lipid molecular species within a complex biological sample and therefore requires a well optimized method for lipid profiling. In this chapter, the methods for lipidomic analysis, including sample collection and preparation, lipid derivatization and separation, mass spectrometric identification of lipids, data processing and interpretation, and quality control, are overviewed.
Collapse
|
15
|
Recent advances in the determination of unbound concentration and plasma protein binding of drugs: Analytical methods. Talanta 2021; 225:122052. [DOI: 10.1016/j.talanta.2020.122052] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2020] [Revised: 12/17/2020] [Accepted: 12/23/2020] [Indexed: 02/08/2023]
|
16
|
Bojko B, Looby N, Olkowicz M, Roszkowska A, Kupcewicz B, Reck Dos Santos P, Ramadan K, Keshavjee S, Waddell TK, Gómez-Ríos G, Tascon M, Goryński K, Cypel M, Pawliszyn J. Solid phase microextraction chemical biopsy tool for monitoring of doxorubicin residue during in vivo lung chemo-perfusion. J Pharm Anal 2020; 11:37-47. [PMID: 33717610 PMCID: PMC7930785 DOI: 10.1016/j.jpha.2020.08.011] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Revised: 08/24/2020] [Accepted: 08/24/2020] [Indexed: 12/24/2022] Open
Abstract
Development of a novel in vivo lung perfusion (IVLP) procedure allows localized delivery of high-dose doxorubicin (DOX) for targeting residual micrometastatic disease in the lungs. However, DOX delivery via IVLP requires careful monitoring of drug level to ensure tissue concentrations of this agent remain in the therapeutic window. A small dimension nitinol wire coated with a sorbent of biocompatible morphology (Bio-SPME) has been clinically evaluated for in vivo lung tissue extraction and determination of DOX and its key metabolites. The in vivo Bio-SPME-IVLP experiments were performed on pig model over various (150 and 225 mg/m2) drug doses, and during human clinical trial. Two patients with metastatic osteosarcoma were treated with a single 5 and 7 μg/mL (respectively) dose of DOX during a 3-h IVLP. In both pig and human cases, DOX tissue levels presented similar trends during IVLP. Human lung tissue concentrations of drug ranged between 15 and 293 μg/g over the course of the IVLP procedure. In addition to DOX levels, Bio-SPME followed by liquid chromatography-mass spectrometry analysis generated 64 metabolic features during endogenous metabolite screening, providing information about lung status during drug administration. Real-time monitoring of DOX levels in the lungs can be performed effectively throughout the IVLP procedure by in vivo Bio-SPME chemical biopsy approach. Bio-SPME also extracted various endogenous molecules, thus providing a real-time snapshot of the physiology of the cells, which might assist in the tailoring of personalized treatment strategy.
Collapse
Affiliation(s)
- Barbara Bojko
- Department of Chemistry, University of Waterloo, Waterloo, ON M1B 6G3, Canada.,Department of Pharmacodynamics and Molecular Pharmacology, Faculty of Pharmacy, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Torun, 85-089, Bydgoszcz, Poland
| | - Nikita Looby
- Department of Chemistry, University of Waterloo, Waterloo, ON M1B 6G3, Canada
| | - Mariola Olkowicz
- Department of Chemistry, University of Waterloo, Waterloo, ON M1B 6G3, Canada.,Jagiellonian Centre for Experimental Therapeutics (JCET), Jagiellonian University, 30-348 Krakow, Poland
| | - Anna Roszkowska
- Department of Chemistry, University of Waterloo, Waterloo, ON M1B 6G3, Canada.,Department of Pharmaceutical Chemistry, Medical University of Gdansk, 80-416, Gdansk, Poland
| | - Bogumiła Kupcewicz
- Department of Inorganic and Analytical Chemistry, Faculty of Pharmacy, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Torun, 85-089, Bydgoszcz, Poland
| | | | - Khaled Ramadan
- University Health Network - TGH, Toronto, ON M5G 2C4, Canada
| | - Shaf Keshavjee
- University Health Network - TGH, Toronto, ON M5G 2C4, Canada
| | | | - German Gómez-Ríos
- Department of Chemistry, University of Waterloo, Waterloo, ON M1B 6G3, Canada
| | - Marcos Tascon
- Department of Chemistry, University of Waterloo, Waterloo, ON M1B 6G3, Canada
| | - Krzysztof Goryński
- Department of Chemistry, University of Waterloo, Waterloo, ON M1B 6G3, Canada.,Department of Pharmacodynamics and Molecular Pharmacology, Faculty of Pharmacy, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Torun, 85-089, Bydgoszcz, Poland
| | - Marcelo Cypel
- University Health Network - TGH, Toronto, ON M5G 2C4, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, ON M1B 6G3, Canada
| |
Collapse
|
17
|
A green - high throughput –extraction method based on hydrophobic natural deep eutectic solvent for the determination of emerging contaminants in water by high performance liquid chromatography – diode array detection. J Chromatogr A 2020; 1626:461377. [DOI: 10.1016/j.chroma.2020.461377] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Revised: 06/16/2020] [Accepted: 06/28/2020] [Indexed: 11/18/2022]
|
18
|
Benvenuti S, Mazzoncini M, Cioni PL, Flamini G. Wildflower-pollinator interactions: Which phytochemicals are involved? Basic Appl Ecol 2020. [DOI: 10.1016/j.baae.2020.03.008] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
19
|
Maciążek-Jurczyk M, Bessonneau V, Ings J, Bragg L, McMaster M, Servos MR, Bojko B, Pawliszyn J. Development of a thin-film solid-phase microextraction (TF-SPME) method coupled to liquid chromatography and tandem mass spectrometry for high-throughput determination of steroid hormones in white sucker fish plasma. Anal Bioanal Chem 2020; 412:4183-4194. [PMID: 32361868 DOI: 10.1007/s00216-020-02657-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2020] [Revised: 03/28/2020] [Accepted: 04/09/2020] [Indexed: 10/24/2022]
Abstract
Steroid hormones (SH) play a number of important physiological roles in vertebrates including fish. Changes in SH concentration significantly affect reproduction, differentiation, development, or metabolism. The objective of this study was to develop an in vitro high-throughput thin-film solid-phase microextraction (TF-SPME)-liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for targeted analysis of endogenous SH (cortisol, testosterone, progesterone, estrone (E1), 17β-estradiol (E2), and 17α-ethinylestradiol (EE2)) in wild white sucker fish plasma where the concentrations of the analytes are substantially low. A simple TF-SPME method enabled the simultaneous determination of free and total SH concentrations. The use of biocompatible coating allowed direct extraction of these hormones from complex biological samples without prior preparation. The carryover was less than 3%, thereby ensuring reusability of the devices and reproducibility. The results showed that TF-SPME was suitable for the analysis of compounds in the polarity range between 1.28 and 4.31 such as SH at different physicochemical properties. The proposed method was validated according to bioanalytical method validation guidelines. The limit of detection (LOD) and limit of quantification(LOQ) for cortisol, testosterone, progesterone, E1, E2, and EE2 were from 0.006 to 0.150 ng/mL and from 0.020 to 0.500 ng/mL, respectively. The recovery for the method was about 85%, and the accuracy and precision of the method for cortisol, testosterone, and progesterone were ≤ 6.0% and ≤ 11.2%, respectively, whereas those for E1, E2, and EE2 were ≤ 15.0% and ≤ 10.2%, respectively. On the basis of this study, TF-SPME demonstrated several important advantages such as simplicity, sensitivity, and robustness under laboratory conditions. Graphical abstract.
Collapse
Affiliation(s)
- Małgorzata Maciążek-Jurczyk
- Department of Chemistry, University of Waterloo, Waterloo, Ontario, N2L 3G1, Canada.,Department of Physical Pharmacy, Faculty of Pharmaceutical Sciences in Sosnowiec, Medical University of Silesia in Katowice, 41-200, Sosnowiec, Poland
| | - Vincent Bessonneau
- Department of Chemistry, University of Waterloo, Waterloo, Ontario, N2L 3G1, Canada
| | - Jennifer Ings
- Enviroment and Climate Change Canada, Burlington, Ontario, L7S 1A1, Canada
| | - Leslie Bragg
- Department of Biology, University of Waterloo, N2L 3G1, Waterloo, Ontario, Canada
| | - Mark McMaster
- Enviroment and Climate Change Canada, Burlington, Ontario, L7S 1A1, Canada
| | - Mark R Servos
- Department of Biology, University of Waterloo, N2L 3G1, Waterloo, Ontario, Canada
| | - Barbara Bojko
- Department of Chemistry, University of Waterloo, Waterloo, Ontario, N2L 3G1, Canada.,Department of Pharmacodynamics and Molecular Pharmacology, Faculty of Pharmacy, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Toruń, 85-089, Bydgoszcz, Poland
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, Ontario, N2L 3G1, Canada.
| |
Collapse
|
20
|
A model to assess acute and delayed lung toxicity of oxaliplatin during in vivo lung perfusion. J Thorac Cardiovasc Surg 2020; 161:1626-1635. [PMID: 32354628 DOI: 10.1016/j.jtcvs.2020.03.033] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/28/2019] [Revised: 03/06/2020] [Accepted: 03/08/2020] [Indexed: 11/23/2022]
Abstract
OBJECTIVES To determine the dose-limiting toxicity of oxaliplatin chemotherapy delivered by in vivo lung perfusion (IVLP). To allow assessment of subacute toxicities, we aimed to develop a 72-hour porcine IVLP survival model. METHODS In total, 12 Yorkshire male pigs were used. Left lung IVLP was performed for 3 hours. At 72 hours postoperatively, computed tomography imaging of the lungs was performed before the pigs were killed. Lung physiology, airway dynamics, gross appearance, and histology were assessed before and during IVLP, at reperfusion, and when the pigs were euthanized. An accelerated titration dose-escalation study design was employed whereby oxaliplatin doses were sequentially doubled provided no clinically significant toxicity was observed, defined as an arterial partial pressure of oxygen to fraction of inspired oxygen ratio <300 mm Hg or severe acute lung injury on biopsy. RESULTS After an initial training phase, no mortality or adverse events related to the procedure were observed. There was no lung injury observed at the time of IVLP for any case. At sacrifice, clinically significant lung injury was observed at 80 mg/L oxaliplatin, with an arterial partial pressure of oxygen to fraction of inspired oxygen ratio of 112 mm Hg. Mild and subclinical lung injury was observed at 40 mg/L, with this dose being repeated to confirm safety. CONCLUSIONS A stable and reproducible porcine 3-day IVLP survival model was established that will allow toxicity assessment of agents delivered by IVLP. Oxaliplatin delivered by IVLP showed delayed-onset toxicity that was not apparent at the time of reperfusion, with a maximal-tolerated dose of 40 mg/L. This information will inform initiation of a clinical trial examining IVLP delivery of oxaliplatin at our institution.
Collapse
|
21
|
Manousi N, Tzanavaras PD, Zacharis CK. Bioanalytical HPLC Applications of In-Tube Solid Phase Microextraction: A Two-Decade Overview. Molecules 2020; 25:molecules25092096. [PMID: 32365828 PMCID: PMC7248733 DOI: 10.3390/molecules25092096] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 04/28/2020] [Accepted: 04/29/2020] [Indexed: 12/18/2022] Open
Abstract
In-tube solid phase microextraction is a cutting-edge sample treatment technique offering significant advantages in terms of miniaturization, green character, automation, and preconcentration prior to analysis. During the past years, there has been a considerable increase in the reported publications, as well as in the research groups focusing their activities on this technique. In the present review article, HPLC bioanalytical applications of in-tube SPME are discussed, covering a wide time frame of twenty years of research reports. Instrumental aspects towards the coupling of in-tube SPME and HPLC are also discussed, and detailed information on materials/coatings and applications in biological samples are provided.
Collapse
Affiliation(s)
- Natalia Manousi
- Laboratory of Analytical Chemistry, School of Chemistry, Faculty of Sciences, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece; (N.M.); (P.D.T.)
| | - Paraskevas D. Tzanavaras
- Laboratory of Analytical Chemistry, School of Chemistry, Faculty of Sciences, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece; (N.M.); (P.D.T.)
| | - Constantinos K. Zacharis
- Laboratory of Pharmaceutical Analysis, Department of Pharmaceutical Technology, School of Pharmacy, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece
- Correspondence: ; Tel.: +30-231-099-7663
| |
Collapse
|
22
|
Jalili V, Barkhordari A, Ghiasvand A. Bioanalytical Applications of Microextraction Techniques: A Review of Reviews. Chromatographia 2020. [DOI: 10.1007/s10337-020-03884-1] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
23
|
Zhang Z, Zhao H, Shen Q, Qi P, Wang X, Xu H, Di S, Wang Z. High‐throughput determination of fungicides in grapes using thin‐film microextraction coupled with liquid chromatography–tandem mass spectrometry. J Sep Sci 2020; 43:1558-1565. [DOI: 10.1002/jssc.201900900] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2019] [Revised: 01/20/2020] [Accepted: 02/04/2020] [Indexed: 01/25/2023]
Affiliation(s)
- Zong‐hui Zhang
- Key Laboratory of Flexible Electronics & Institute of Advanced MaterialsJiangsu National Synergetic Innovation Center for Advanced MaterialsNanjing Tech University Nanjing P. R. China
- Institute of Quality and Standards for Agricultural ProductsZhejiang Academy of Agricultural Sciences Hangzhou P. R. China
| | - Hui‐yu Zhao
- Institute of Quality and Standards for Agricultural ProductsZhejiang Academy of Agricultural Sciences Hangzhou P. R. China
| | - Qian Shen
- Key Laboratory of Flexible Electronics & Institute of Advanced MaterialsJiangsu National Synergetic Innovation Center for Advanced MaterialsNanjing Tech University Nanjing P. R. China
| | - Pei‐pei Qi
- Institute of Quality and Standards for Agricultural ProductsZhejiang Academy of Agricultural Sciences Hangzhou P. R. China
| | - Xin‐quan Wang
- Institute of Quality and Standards for Agricultural ProductsZhejiang Academy of Agricultural Sciences Hangzhou P. R. China
| | - Hao Xu
- Institute of Quality and Standards for Agricultural ProductsZhejiang Academy of Agricultural Sciences Hangzhou P. R. China
| | - Shan‐shan Di
- Institute of Quality and Standards for Agricultural ProductsZhejiang Academy of Agricultural Sciences Hangzhou P. R. China
| | - Zhi‐wei Wang
- Institute of Quality and Standards for Agricultural ProductsZhejiang Academy of Agricultural Sciences Hangzhou P. R. China
| |
Collapse
|
24
|
Hossain SMZ, Razzak SA, Hossain MM. Application of Essential Oils as Green Corrosion Inhibitors. ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING 2020. [DOI: 10.1007/s13369-019-04305-8] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
25
|
|
26
|
Rao TS, Sridevi M, Naidu CG, Nagaraju B. Ionic liquid-based vortex-assisted DLLME followed by RP-LC-PDA method for bioassay of daclatasvir in rat serum: application to pharmacokinetics. J Anal Sci Technol 2019. [DOI: 10.1186/s40543-019-0179-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
27
|
|
28
|
Qiu J, Ouyang G, Pawliszyn J, Schlenk D, Gan J. A Novel Water-Swelling Sampling Probe for in Vivo Detection of Neonicotinoids in Plants. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2019; 53:9686-9694. [PMID: 31313572 DOI: 10.1021/acs.est.9b01682] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Ecotoxicological risks of neonicotinoid insecticides are raising significant concerns, including their potential role in bee population declines. Neonicotinoids are water-soluble, systemic insecticides, and exposure of nontarget organisms such as pollinators occurs mainly through residues in nectar and pollens of flowering plants. To better elucidate the underlying mechanisms for such nontarget exposure, it is highly valuable to develop analytical capabilities for in vivo monitoring of neonicotinoids in live plants. In this study, we developed a novel biomimetic water-swelling solid-phase microextraction (SPME) probe, with limits of detection for neonicotinoids as low as 0.03 ng mL-1, and applied it for in vivo detection of seven neonicotinoids in plant sap. The preparation of this fiber was simple and free of stringent or complex physical-chemical reactions. Equilibrium in neonicotinoid accumulation on the fiber was reached in <10 min, allowing for near instantaneous sampling. The water-swelling fiber displayed much greater sampling capacity than the commercially available polydimethylsiloxane and polyacrylate fibers, good reproducibility (RSD of inter- and intrafiber <8.9% and 7.8%, respectively), and antibiofouling property (no loss in performance after 20 use cycles). After treating lettuce (Lactuca sativa L.) by foliar spray and soybean (Glycine max M.) by seed soaking, the in vivo assays provided a wealth of information, including changes in levels and distribution of neonicotinoids over time in the same plants. Kinetics and distribution patterns suggested that after treatment at the same level, neonicotinoids differed significantly in their levels in the sap. The in vivo sampling and monitoring of neonicotinoids in live plants may provide unique and much needed information in achieving breakthrough understanding of the connection between neonicotinoid use and pollinator exposure.
Collapse
Affiliation(s)
- Junlang Qiu
- Department of Environmental Sciences , University of California , Riverside , California 92521 , United States
- School of Chemistry , Sun Yat-Sen University , Guangzhou 510275 , China
| | - Gangfeng Ouyang
- School of Chemistry , Sun Yat-Sen University , Guangzhou 510275 , China
| | - Janusz Pawliszyn
- Department of Chemistry , University of Waterloo , 200 University Avenue West , Waterloo , Ontario N2L3G1 , Canada
| | - Daniel Schlenk
- Department of Environmental Sciences , University of California , Riverside , California 92521 , United States
| | - Jay Gan
- Department of Environmental Sciences , University of California , Riverside , California 92521 , United States
| |
Collapse
|
29
|
Hu B, Zheng B, Rickert D, Gómez-Ríos GA, Bojko B, Pawliszyn J, Yao ZP. Direct coupling of solid phase microextraction with electrospray ionization mass spectrometry: A Case study for detection of ketamine in urine. Anal Chim Acta 2019; 1075:112-119. [PMID: 31196416 DOI: 10.1016/j.aca.2019.05.044] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2019] [Revised: 05/16/2019] [Accepted: 05/17/2019] [Indexed: 12/28/2022]
Abstract
Electrospray ionization mass spectrometry (ESI-MS) is a commonly used technique for analysis of various samples. Solid phase microextraction (SPME) is a simple and efficient technique that combines both sampling and sample preparation into one consolidated step, preconcentrating extracted analytes for ultra-sensitive analysis. Historically, SPME has been coupled with chromatography-based techniques for sample separation prior to analysis, however more recently, the chromatographic step has been omitted, with the SPME device directly coupled with the mass spectrometer. In this study, direct coupling of SPME with ESI-MS was developed, and extensively validated to quantitate ketamine from human urine, employing a practical experimental workflow and no extensive hardware modification to the equipment. Among the different fibers evaluated, SPME device coated with C18/benzenesulfonic acid particles was selected for the analysis due to its good selectivity and signal response. Different approaches, including desorption spray, dripping, desorption ESI and nano-ESI were attempted for elution and ionization of the analytes extracted using the SPME fibers. The results showed that the desorption spray and nano-ESI methods offered better signal response and signal duration than the others that were evaluated. The analytical performance of the SPME-nano-ESI-MS setup was excellent, including limit of detection (LOD) of 0.027 ng/mL, limit of quantitation (LOQ) of 0.1 ng/mL, linear range of 0.1-500.0 ng/mL (R2 = 0.9995) and recoveries of 90.8-109.4% with RSD 3.4-10.6% for three validation points at 4.0, 40.0 and 400.0 ng/mL, far better than the performance of conventional methods. The results herein presented, demonstrated that the direct coupling of SPME fibers with ESI-MS-based systems allowed for the simple and ultra-sensitive determination of analytes from raw samples such as human urine.
Collapse
Affiliation(s)
- Bin Hu
- State Key Laboratory of Chemical Biology and Drug Discovery, Food Safety and Technology Research Centre and Department of Applied Biology and Chemical Technology, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong Special Administrative Region, China; State Key Laboratory of Chinese Medicine and Molecular Pharmacology (Incubation) and Shenzhen Key Laboratory of Food Biological Safety Control, Shenzhen Research Institute of The Hong Kong Polytechnic University, Shenzhen, 518057, China; Institute of Mass Spectrometer and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Jinan University, Guangzhou, 510632, China
| | - Bo Zheng
- State Key Laboratory of Chemical Biology and Drug Discovery, Food Safety and Technology Research Centre and Department of Applied Biology and Chemical Technology, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong Special Administrative Region, China; State Key Laboratory of Chinese Medicine and Molecular Pharmacology (Incubation) and Shenzhen Key Laboratory of Food Biological Safety Control, Shenzhen Research Institute of The Hong Kong Polytechnic University, Shenzhen, 518057, China
| | - Daniel Rickert
- Department of Chemistry, University of Waterloo, Waterloo, ON, N2L 3G1, Canada
| | | | - Barbara Bojko
- Department of Chemistry, University of Waterloo, Waterloo, ON, N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, ON, N2L 3G1, Canada.
| | - Zhong-Ping Yao
- State Key Laboratory of Chemical Biology and Drug Discovery, Food Safety and Technology Research Centre and Department of Applied Biology and Chemical Technology, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong Special Administrative Region, China; State Key Laboratory of Chinese Medicine and Molecular Pharmacology (Incubation) and Shenzhen Key Laboratory of Food Biological Safety Control, Shenzhen Research Institute of The Hong Kong Polytechnic University, Shenzhen, 518057, China.
| |
Collapse
|
30
|
Gorynski K. A critical review of solid-phase microextraction applied in drugs of abuse determinations and potential applications for targeted doping testing. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2018.12.029] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
31
|
Reimerová P, Stariat J, Bavlovič Piskáčková H, Jansová H, Roh J, Kalinowski DS, Macháček M, Šimůnek T, Richardson DR, Štěrbová-Kovaříková P. Novel SPME fibers based on a plastic support for determination of plasma protein binding of thiosemicarbazone metal chelators: a case example of DpC, an anti-cancer drug that entered clinical trials. Anal Bioanal Chem 2019; 411:2383-2394. [PMID: 30820631 DOI: 10.1007/s00216-019-01681-w] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2018] [Accepted: 02/07/2019] [Indexed: 12/31/2022]
Abstract
Solid-phase microextraction (SPME) is an alternative method to dialysis and ultrafiltration for the determination of plasma protein binding (PPB) of drugs. It is particularly advantageous for complicated analytes where standard methods are not applicable. Di-2-pyridylketone 4-cyclohexyl-4-methyl-3-thiosemicarbazone (DpC) is a lead compound of novel thiosemicarbazone anti-cancer drugs, which entered clinical trials in 2016. However, this agent exhibited non-specific binding on filtration membranes and had intrinsic chelation activity, which precluded standard PPB methods. In this study, using a simple and fast procedure, we prepared novel SPME fibers for extraction of DpC based on a metal-free, silicon string support, covered with C18 sorbent. Reproducibility of the preparation process was demonstrated by the percent relative standard deviation (RSD) of ≤ 9.2% of the amount of DpC extracted from PBS by several independently prepared fibers. The SPME procedure was optimized by evaluating extraction and desorption time profiles. Suitability of the optimized protocol was verified by examining reproducibility, linearity, and recovery of DpC extracted from PBS or plasma. All samples extracted by SPME were analyzed using an optimized and validated UHPLC-MS/MS method. The developed procedure was applied to the in vitro determination of PPB of DpC at two clinically relevant concentrations (500 and 1000 ng/mL). These studies showed that DpC is highly bound to plasma proteins (PPB ≥ 88%) and this did not differ significantly between both concentrations tested. This investigation provides novel data in the applicability of SPME for the determination of PPB of chelators, as well as useful information for the clinical development of DpC. Graphical abstract.
Collapse
Affiliation(s)
- Petra Reimerová
- Faculty of Pharmacy in Hradec Kralove, Charles University, Heyrovskeho 1203, 500 05, Hradec Kralove, Czech Republic
| | - Ján Stariat
- Faculty of Pharmacy in Hradec Kralove, Charles University, Heyrovskeho 1203, 500 05, Hradec Kralove, Czech Republic
| | - Hana Bavlovič Piskáčková
- Faculty of Pharmacy in Hradec Kralove, Charles University, Heyrovskeho 1203, 500 05, Hradec Kralove, Czech Republic
| | - Hana Jansová
- Faculty of Pharmacy in Hradec Kralove, Charles University, Heyrovskeho 1203, 500 05, Hradec Kralove, Czech Republic
| | - Jaroslav Roh
- Faculty of Pharmacy in Hradec Kralove, Charles University, Heyrovskeho 1203, 500 05, Hradec Kralove, Czech Republic
| | - Danuta S Kalinowski
- Molecular Pharmacology and Pathology Program, Department of Pathology and Bosch Institute, University of Sydney, Sydney, New South Wales, 2006, Australia
| | - Miloslav Macháček
- Faculty of Pharmacy in Hradec Kralove, Charles University, Heyrovskeho 1203, 500 05, Hradec Kralove, Czech Republic
| | - Tomáš Šimůnek
- Faculty of Pharmacy in Hradec Kralove, Charles University, Heyrovskeho 1203, 500 05, Hradec Kralove, Czech Republic
| | - Des R Richardson
- Molecular Pharmacology and Pathology Program, Department of Pathology and Bosch Institute, University of Sydney, Sydney, New South Wales, 2006, Australia.
| | - Petra Štěrbová-Kovaříková
- Faculty of Pharmacy in Hradec Kralove, Charles University, Heyrovskeho 1203, 500 05, Hradec Kralove, Czech Republic.
| |
Collapse
|
32
|
Development, Optimization, and Validation of the HS-SPME/GC-MS Method for the Residual Determination of Menthol in Fish. FOOD ANAL METHOD 2019. [DOI: 10.1007/s12161-019-01467-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
33
|
Current direction and advances in analytical sample extraction techniques for drugs with special emphasis on bioanalysis. Bioanalysis 2019; 11:313-332. [PMID: 30663327 DOI: 10.4155/bio-2018-0144] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
Analytical techniques may not be compatible or sufficiently sensitive to the analytes, unless it undergoes a specific sample extraction procedure. Sample extraction can be considered as one of the key steps in analysis. Analysis of a poorly treated sample may produce inferior quality of analytical data. Continuous advancement and development of newer sample extraction techniques such as solid phase microextraction, ultrasound, magnetically and microwave assisted magnetic extraction; electro-membrane extraction and dried blood spotting are to address the shortcomings of the existing techniques and to provide more automation, minimizing preparation time and make them high throughput. This review summarizes the suitability of application of the advanced sample preparation techniques available for chemical and bioanalysis in a comprehensive manner. This review also provides a scientific guidance for selecting the appropriate sample extraction technique based on sample type.
Collapse
|
34
|
Khaled A, Gionfriddo E, Acquaro V, Singh V, Pawliszyn J. Development and validation of a fully automated solid phase microextraction high throughput method for quantitative analysis of multiresidue veterinary drugs in chicken tissue. Anal Chim Acta 2018; 1056:34-46. [PMID: 30797459 DOI: 10.1016/j.aca.2018.12.044] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2018] [Revised: 12/20/2018] [Accepted: 12/21/2018] [Indexed: 12/24/2022]
Abstract
This paper presents the development and validation of a fully automated, high-throughput multiclass, multiresidue method for quantitative analysis of 77 veterinary drugs in chicken muscle via direct immersion solid phase microextraction (DI-SPME) and ultra-high pressure liquid chromatography-electrospray ionization - tandem mass spectrometry (UHPLC-ESI-MS/MS). The selected drugs represent more than 12 different classes of drugs characterized by varying physical and chemical properties. A Hydrophilic-lipophilic balance (HLB)/polyacrylonitrile (PAN) extraction phase, prepared using HLB particles synthesized in-house, yielded the best extraction/desorption performance among four different SPME extraction phases evaluated in the current work. The developed SPME method was optimized in terms of SPME coating and geometry, desorption solvent, extraction and rinsing conditions, and extraction and desorption times. Multivariate analysis was performed to determine the optimal desorption solvent for the proposed application. The developed method was validated according to the Food and Drug Administration (FDA) guidelines, taking into account Canadian maximum residue limits (MRLs) and US maximum tolerance levels for veterinary drugs in meat. Method accuracy ranged from 80 to 120% for at least 73 compounds, with relative standard deviation of 1-15%. Inter-day precision ranged from 4 to 15% for 70 compounds. Determination coefficients values were higher than 0.991 for all compounds under study with no significant lack of fit (p > 0.05) at the 5% level. In terms of limits of quantitation, the method was able to meet both Canadian and US regulatory levels for all compounds under study.
Collapse
Affiliation(s)
- Abir Khaled
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada
| | - Emanuela Gionfriddo
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada; Department of Chemistry and Biochemistry, The University of Toledo, Toledo, OH, USA
| | - Vinicius Acquaro
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada; Departamento de Química, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, SP, Brazil
| | - Varoon Singh
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada.
| |
Collapse
|
35
|
Sajid M, Khaled Nazal M, Rutkowska M, Szczepańska N, Namieśnik J, Płotka-Wasylka J. Solid Phase Microextraction: Apparatus, Sorbent Materials, and Application. Crit Rev Anal Chem 2018; 49:271-288. [DOI: 10.1080/10408347.2018.1517035] [Citation(s) in RCA: 54] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Affiliation(s)
- Muhammad Sajid
- Center for Environment and Water, Research Institute King Fahd University of Petroleum and Minerals, Dhahran, Saudi Arabia
| | - Mazen Khaled Nazal
- Center for Environment and Water, Research Institute King Fahd University of Petroleum and Minerals, Dhahran, Saudi Arabia
| | - Małgorzata Rutkowska
- Department of Analytical Chemistry, Faculty of Chemistry, Gdańsk University of Technology, Gdańsk, Poland
| | - Natalia Szczepańska
- Department of Analytical Chemistry, Faculty of Chemistry, Gdańsk University of Technology, Gdańsk, Poland
| | - Jacek Namieśnik
- Department of Analytical Chemistry, Faculty of Chemistry, Gdańsk University of Technology, Gdańsk, Poland
| | - Justyna Płotka-Wasylka
- Department of Analytical Chemistry, Faculty of Chemistry, Gdańsk University of Technology, Gdańsk, Poland
| |
Collapse
|
36
|
He Y, Concheiro-Guisan M. Microextraction sample preparation techniques in forensic analytical toxicology. Biomed Chromatogr 2018; 33:e4444. [DOI: 10.1002/bmc.4444] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2018] [Accepted: 11/15/2018] [Indexed: 12/14/2022]
Affiliation(s)
- Yi He
- Department of Sciences, John Jay College of Criminal Justice; The City University of New York; New York NY USA
| | - Marta Concheiro-Guisan
- Department of Sciences, John Jay College of Criminal Justice; The City University of New York; New York NY USA
| |
Collapse
|
37
|
Bongaerts J, De Bundel D, Mangelings D, Smolders I, Vander Heyden Y, Van Eeckhaut A. Sensitive targeted methods for brain metabolomic studies in microdialysis samples. J Pharm Biomed Anal 2018; 161:192-205. [DOI: 10.1016/j.jpba.2018.08.043] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2018] [Revised: 08/20/2018] [Accepted: 08/21/2018] [Indexed: 02/06/2023]
|
38
|
Belinato JR, Dias FFG, Caliman JD, Augusto F, Hantao LW. Opportunities for green microextractions in comprehensive two-dimensional gas chromatography / mass spectrometry-based metabolomics - A review. Anal Chim Acta 2018; 1040:1-18. [PMID: 30327098 DOI: 10.1016/j.aca.2018.08.034] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2018] [Revised: 08/15/2018] [Accepted: 08/17/2018] [Indexed: 10/28/2022]
Abstract
Microextractions have become an attractive class of techniques for metabolomics. The most popular technique is solid-phase microextraction that revolutionized the field of modern sample preparation in the early nineties. Ever since this milestone, microextractions have taken on many principles and formats comprising droplets, fibers, membranes, needles, and blades. Sampling devices may be customized to impart exhaustive or equilibrium-based characteristics to the extraction method. Equilibrium-based approaches may rely on additional methods for calibration, such as diffusion-based or on-fiber kinetic calibration to improve bioanalysis. In addition, microextraction-based methods may enable minimally invasive sampling protocols and measure the average free concentration of analytes in heterogeneous multiphasic biological systems. On-fiber derivatization has evidenced new opportunities for targeted and untargeted analysis in metabolomics. All these advantages have highlighted the potential of microextraction techniques for in vivo and on-site sampling and sample preparation, while many opportunities are still available for laboratory protocols. In this review, we outline and discuss some of the most recent applications using microextractions techniques for comprehensive two-dimensional gas chromatography-based metabolomics, including potential research opportunities.
Collapse
Affiliation(s)
- João R Belinato
- Institute of Chemistry, University of Campinas, Campinas, SP, 13083-970, Brazil; National Institute of Science and Technology in Bioanalysis (INCTBio), Campinas, SP, 13083-970, Brazil
| | - Fernanda F G Dias
- Institute of Chemistry, University of Campinas, Campinas, SP, 13083-970, Brazil; National Institute of Science and Technology in Bioanalysis (INCTBio), Campinas, SP, 13083-970, Brazil
| | - Jaqueline D Caliman
- Institute of Chemistry, University of Campinas, Campinas, SP, 13083-970, Brazil; National Institute of Science and Technology in Bioanalysis (INCTBio), Campinas, SP, 13083-970, Brazil
| | - Fabio Augusto
- Institute of Chemistry, University of Campinas, Campinas, SP, 13083-970, Brazil; National Institute of Science and Technology in Bioanalysis (INCTBio), Campinas, SP, 13083-970, Brazil
| | - Leandro W Hantao
- Institute of Chemistry, University of Campinas, Campinas, SP, 13083-970, Brazil.
| |
Collapse
|
39
|
Vuckovic D. Improving metabolome coverage and data quality: advancing metabolomics and lipidomics for biomarker discovery. Chem Commun (Camb) 2018; 54:6728-6749. [PMID: 29888773 DOI: 10.1039/c8cc02592d] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
This Feature Article highlights some of the key challenges within the field of metabolomics and examines what role separation and analytical sciences can play to improve the use of metabolomics in biomarker discovery and personalized medicine. Recent progress in four key areas is highlighted: (i) improving metabolite coverage, (ii) developing accurate methods for unstable metabolites including in vivo global metabolomics methods, (iii) advancing inter-laboratory studies and reference materials and (iv) improving data quality, standardization and quality control of metabolomics studies.
Collapse
Affiliation(s)
- Dajana Vuckovic
- Department of Chemistry and Biochemistry, Concordia University, 7141 Sherbrooke Street West, Montréal, Québec H4B 1R6, Canada.
| |
Collapse
|
40
|
Extracellular Microbial Metabolomics: The State of the Art. Metabolites 2017; 7:metabo7030043. [PMID: 28829385 PMCID: PMC5618328 DOI: 10.3390/metabo7030043] [Citation(s) in RCA: 68] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2017] [Revised: 08/21/2017] [Accepted: 08/22/2017] [Indexed: 02/04/2023] Open
Abstract
Microorganisms produce and secrete many primary and secondary metabolites to the surrounding environment during their growth. Therefore, extracellular metabolites provide important information about the changes in microbial metabolism due to different environmental cues. The determination of these metabolites is also comparatively easier than the extraction and analysis of intracellular metabolites as there is no need for cell rupture. Many analytical methods are already available and have been used for the analysis of extracellular metabolites from microorganisms over the last two decades. Here, we review the applications and benefits of extracellular metabolite analysis. We also discuss different sample preparation protocols available in the literature for both types (e.g., metabolites in solution and in gas) of extracellular microbial metabolites. Lastly, we evaluate the authenticity of using extracellular metabolomics data in the metabolic modelling of different industrially important microorganisms.
Collapse
|
41
|
Seifertová M, Čechová E, Llansola M, Felipo V, Vykoukalová M, Kočan A. Determination of selected neurotoxic insecticides in small amounts of animal tissue utilizing a newly constructed mini-extractor. Anal Bioanal Chem 2017; 409:6015-6026. [DOI: 10.1007/s00216-017-0533-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2017] [Revised: 07/09/2017] [Accepted: 07/17/2017] [Indexed: 01/02/2023]
|
42
|
Piri-Moghadam H, Alam MN, Pawliszyn J. Review of geometries and coating materials in solid phase microextraction: Opportunities, limitations, and future perspectives. Anal Chim Acta 2017; 984:42-65. [PMID: 28843569 DOI: 10.1016/j.aca.2017.05.035] [Citation(s) in RCA: 208] [Impact Index Per Article: 29.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2017] [Revised: 05/23/2017] [Accepted: 05/25/2017] [Indexed: 12/18/2022]
Abstract
The development of new support and geometries of solid phase microextraction (SPME), including metal fiber assemblies, coated-tip, and thin film microextraction (TFME) (i.e. self-supported, fabric and blade supported), as well as their effects on diffusion and extraction rate of analytes were discussed in the current review. Application of main techniques widely used for preparation of a variety of coating materials of SPME, including sol-gel technique, electrochemical and electrospinning methods as well as the available commercial coatings, were presented. Advantages and limitations of each technique from several aspects, such as range of application, biocompatibility, availability in different geometrical configurations, method of preparation, incorporation of various materials to tune the coating properties, and thermal and physical stability, were also investigated. Future perspectives of each technique to improve the efficiency and stability of the coatings were also summarized. Some interesting materials including ionic liquids (ILs), metal organic frameworks (MOFs) and particle loaded coatings were briefly presented.
Collapse
Affiliation(s)
- Hamed Piri-Moghadam
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| | - Md Nazmul Alam
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada.
| |
Collapse
|
43
|
Shang B, Peng T, Zhang H, Wang H, Yu F, Chen Q. Sensitive determination of yohimbine in plasma by micropipette tip-based poly(methacrylic acid- co-ethylene glycol dimethacrylate) monolith SPME coupled with HPLC method. J LIQ CHROMATOGR R T 2017. [DOI: 10.1080/10826076.2017.1318398] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Affiliation(s)
- Bing Shang
- School of Pharmacy, Hubei University of Science and Technology, Xianning, China
- Affiliated Dongfeng Hospital, Hubei University of Medicine, Shiyan, Hubei, China
| | - Tao Peng
- Affiliated Dongfeng Hospital, Hubei University of Medicine, Shiyan, Hubei, China
| | - Hua Zhang
- Affiliated Dongfeng Hospital, Hubei University of Medicine, Shiyan, Hubei, China
| | - Hongmei Wang
- Affiliated Dongfeng Hospital, Hubei University of Medicine, Shiyan, Hubei, China
| | - Fei Yu
- Affiliated Dongfeng Hospital, Hubei University of Medicine, Shiyan, Hubei, China
| | - Qinhua Chen
- School of Pharmacy, Hubei University of Science and Technology, Xianning, China
- Affiliated Dongfeng Hospital, Hubei University of Medicine, Shiyan, Hubei, China
| |
Collapse
|
44
|
Jurowski K, Kochan K, Walczak J, Barańska M, Piekoszewski W, Buszewski B. Comprehensive review of trends and analytical strategies applied for biological samples preparation and storage in modern medical lipidomics: State of the art. Trends Analyt Chem 2017. [DOI: 10.1016/j.trac.2016.10.014] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
45
|
Goryński K, Goryńska P, Górska A, Harężlak T, Jaroch A, Jaroch K, Lendor S, Skobowiat C, Bojko B. SPME as a promising tool in translational medicine and drug discovery: From bench to bedside. J Pharm Biomed Anal 2016; 130:55-67. [DOI: 10.1016/j.jpba.2016.05.012] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2016] [Revised: 05/03/2016] [Accepted: 05/04/2016] [Indexed: 01/11/2023]
|
46
|
Tahmasebi Z, Davarani SSH, Asgharinezhad AA. An efficient approach to selective electromembrane extraction of naproxen by means of molecularly imprinted polymer-coated multi-walled carbon nanotubes-reinforced hollow fibers. J Chromatogr A 2016; 1470:19-26. [DOI: 10.1016/j.chroma.2016.09.067] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2016] [Revised: 09/26/2016] [Accepted: 09/28/2016] [Indexed: 10/20/2022]
|
47
|
Direct tissue sampling of diazepam and amitriptyline using mixed-mode SPME fibers: A feasibility study. Forensic Chem 2016. [DOI: 10.1016/j.forc.2016.07.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
48
|
Bridle HL, Heringa MB, Schäfer AI. Solid-phase microextraction to determine micropollutant–macromolecule partition coefficients. Nat Protoc 2016; 11:1328-44. [DOI: 10.1038/nprot.2016.068] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
49
|
Ryabov AY, Chuikin AV, Velikov AA. Solid-phase microextraction of hydrocarbons from water in a centrifuge. RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY A 2016. [DOI: 10.1134/s0036024416060200] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
50
|
Souza-Silva ÉA, Gionfriddo E, Shirey R, Sidisky L, Pawliszyn J. Methodical evaluation and improvement of matrix compatible PDMS-overcoated coating for direct immersion solid phase microextraction gas chromatography (DI-SPME-GC)-based applications. Anal Chim Acta 2016; 920:54-62. [DOI: 10.1016/j.aca.2016.03.015] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2016] [Accepted: 03/16/2016] [Indexed: 10/22/2022]
|