1
|
GAO F, WANG XF, ZHANG B. Research and Application Progress of Micellar Electrokinetic Chromatography in Separation of Proteins. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2019. [DOI: 10.1016/s1872-2040(19)61163-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
2
|
Abstract
Capillary electrophoresis (CE) is a well-established and one of the most powerful separation techniques in the field of chiral separations. Its hyphenation with mass spectrometry (MS) combines both the high separation efficiency and low sample consumption of CE and the high sensitivity and structural information of MS. Thus, the outstanding chiral resolution power of CE along with the MS advantages makes CE-MS a perfect combination to achieve sensitive enantioseparations. This chapter describes three representative examples of different approaches used in the chiral analysis of amino acids in biological fluids by CE-MS. The first methodology uses the partial filling technique to avoid the entry of cyclodextrins in the MS source. The second method shows the possibility to carry out the direct coupling EKC-MS even when a relative high concentration of a native cyclodextrin is used as chiral selector. The last example illustrates an alternative strategy based on the formation of stable diastereomers between an enantiomerically pure chiral reagent and the amino acids enantiomers which can be separated in an achiral environment.
Collapse
|
3
|
Moreno-González D, Haselberg R, Gámiz-Gracia L, García-Campaña AM, de Jong GJ, Somsen GW. Fully compatible and ultra-sensitive micellar electrokinetic chromatography-tandem mass spectrometry using sheathless porous-tip interfacing. J Chromatogr A 2017; 1524:283-289. [PMID: 28992989 DOI: 10.1016/j.chroma.2017.09.075] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2017] [Revised: 09/26/2017] [Accepted: 09/30/2017] [Indexed: 11/26/2022]
Abstract
The on-line coupling of micellar electrokinetic chromatography and mass spectrometry (MEKC-MS) is often hampered by incompatibility problems leading to reduced separation performance and unfavorable limits of detection (LODs). Here we propose a new selective and highly sensitive MEKC-MS/MS method employing a sheathless porous-tip interface in combination with a micellar phase comprised of semi-volatile surfactant molecules. Carbamate pesticides (CRBs) were selected as representative model compounds being neutral toxic pollutants potentially present at trace levels in environmental water samples. A background electrolyte of 75mM perfluorooctanoic acid adjusted to pH 9.0 with ammonium hydroxide allowed efficient separation of 15 CRBs and appeared fully compatible with electrospray ionization (ESI)-MS. Interfacing parameters, such as the distance between the capillary tip and mass-spectrometer inlet, ESI voltage, and dry gas temperature and flow were optimized in order to attain good spray stability and high analyte signal-to-noise ratios. For CRBs the LODs ranged from 0.2 to 3.9ngL-1 (13nL injected, i.e., 2% of capillary volume), representing an improvement for certain CRBs of more than 300-fold when compared with conventional sheath-liquid interfacing. Good linearity (R2>0.99) and satisfactory reproducibility were obtained for all CRBs with interday RSD values for peak area and migration time of 4.0-11.3% and below 1.5%, respectively. Analysis of spiked mineral water showed that the new MEKC-MS/MS method allows selective and quantitative determination of CRB concentrations below the maximum residue limit of 100ngL-1 without the need for sample preconcentration.
Collapse
Affiliation(s)
- David Moreno-González
- Department of Analytical Chemistry, Faculty of Sciences, University of Granada, Campus Fuentenueva, E-18071 Granada, Spain
| | - Rob Haselberg
- Division of BioAnalytical Chemistry, AIMMS research group BioMolecular Analysis, Faculty of Sciences, Vrije Universiteit Amsterdam, de Boelelaan 1085, 1081 HV Amsterdam, The Netherlands.
| | - Laura Gámiz-Gracia
- Department of Analytical Chemistry, Faculty of Sciences, University of Granada, Campus Fuentenueva, E-18071 Granada, Spain
| | - Ana M García-Campaña
- Department of Analytical Chemistry, Faculty of Sciences, University of Granada, Campus Fuentenueva, E-18071 Granada, Spain
| | - Gerhardus J de Jong
- Biomolecular Analysis, Utrecht University, Universiteitsweg 99, 3584 CG Utrecht, The Netherlands
| | - Govert W Somsen
- Division of BioAnalytical Chemistry, AIMMS research group BioMolecular Analysis, Faculty of Sciences, Vrije Universiteit Amsterdam, de Boelelaan 1085, 1081 HV Amsterdam, The Netherlands
| |
Collapse
|
4
|
Abstract
In clinical metabolomics, capillary electrophoresis-mass spectrometry (CE-MS) has become a very useful technique for the analysis of highly polar and charged metabolites in complex biologic samples. A comprehensive overview of recent developments in CE-MS for metabolic profiling studies is presented. This review covers theory, CE separation modes, capillary coatings, and practical aspects of CE-MS coupling. Attention is also given to sample pretreatment and data analysis strategies used for metabolomics. The applicability of CE-MS for clinical metabolomics is illustrated using samples ranging from plasma and urine to cells and tissues. CE-MS application to large-scale and quantitative clinical metabolomics is addressed. Conclusions and perspectives on this unique analytic strategy are presented.
Collapse
|
5
|
Abstract
Capillary electrophoresis (CE) is a versatile and flexible technique for analytical enantioseparations. This is due to the large variety of chiral selectors as well as the different operation modes including electrokinetic chromatography, micellar electrokinetic chromatography, and microemulsion electrokinetic chromatography. The chiral selector, which is added to the background electrolyte, represents a pseudostationary phase with its own electrophoretic mobility allowing a variety of different separation protocols. The present chapter briefly addresses the basic fundamentals of CE enantioseparations as well as the most frequently applied chiral selectors and separation modes. The practical example illustrates the separation of the enantiomers of a positively charged analyte using native and charged cyclodextrin derivatives as chiral selectors.
Collapse
Affiliation(s)
- Gerhard K E Scriba
- Department of Pharmaceutical Chemistry, University of Jena, Philosophenweg 14, Jena, 07743, Germany.
| | - Henrik Harnisch
- Department of Pharmaceutical Chemistry, University of Jena, Philosophenweg 14, Jena, 07743, Germany
| | - Qingfu Zhu
- Department of Chemistry, Wichita State University, 1845 Fairmount St, Wichita, KS, 67260, USA
| |
Collapse
|
6
|
Wang NH, Her GR. The development of a hydrodynamic flow assisted double junction interface for signal improvement in capillary electrophoresis–mass spectrometry using positively charged nonvolatile additives. J Chromatogr A 2015; 1379:106-11. [DOI: 10.1016/j.chroma.2014.12.046] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2014] [Revised: 12/13/2014] [Accepted: 12/16/2014] [Indexed: 11/27/2022]
|
7
|
Sánchez-López E, Montealegre C, Marina ML, Crego AL. Development of chiral methodologies by capillary electrophoresis with ultraviolet and mass spectrometry detection for duloxetine analysis in pharmaceutical formulations. J Chromatogr A 2014; 1363:356-62. [PMID: 25085818 DOI: 10.1016/j.chroma.2014.07.038] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2014] [Revised: 07/11/2014] [Accepted: 07/14/2014] [Indexed: 10/25/2022]
Abstract
Two chiral methodologies were developed by capillary electrophoresis (CE) with UV and mass spectrometry (MS) detection to ensure the quality control of the drug duloxetine, commercialized as a pure enantiomer. Both methods were optimized to achieve a high baseline enantioresolution (Rs>2) and an acceptable precision (RSD values <5% for instrumental repeatability and <10% for intermediate precision). In addition to allow the unequivocal identification of duloxetine enantiomers, the CE-MS method improved the sensitivity with respect to the use of CE-UV (LOD 200 ng/mL by CE-UV and 20 ng/mL by CE-MS) enabling to detect 0.02% of duloxetine enantiomeric impurity. This is the lowest LOD value ever reported for this drug, being this work the first one enabling to accomplish with the ICH guidelines requirements. The developed methods were validated and applied for the first time to the analysis of four pharmaceutical formulations. The content of R-duloxetine in all these samples was below the detection limit and the amount of S-duloxetine was in good agreement with the labeled content, obtaining results by the two methods that did not differ significantly (p-values >0.05).
Collapse
Affiliation(s)
- Elena Sánchez-López
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Ctra. Madrid-Barcelona Km. 33.600, Alcalá de Henares, 28871 Madrid, Spain
| | - Cristina Montealegre
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Ctra. Madrid-Barcelona Km. 33.600, Alcalá de Henares, 28871 Madrid, Spain
| | - María Luisa Marina
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Ctra. Madrid-Barcelona Km. 33.600, Alcalá de Henares, 28871 Madrid, Spain
| | - Antonio L Crego
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Ctra. Madrid-Barcelona Km. 33.600, Alcalá de Henares, 28871 Madrid, Spain.
| |
Collapse
|
8
|
D’Orazio G, Asensio-Ramos M, Hernández-Borges J, Fanali S, Rodríguez-Delgado MÁ. Estrogenic compounds determination in water samples by dispersive liquid–liquid microextraction and micellar electrokinetic chromatography coupled to mass spectrometry. J Chromatogr A 2014; 1344:109-21. [DOI: 10.1016/j.chroma.2014.04.005] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2013] [Revised: 04/02/2014] [Accepted: 04/03/2014] [Indexed: 11/16/2022]
|
9
|
Li G, Cai C, Li L, Fu L, Chang Y, Zhang F, Toida T, Xue C, Linhardt RJ. Method to detect contaminants in heparin using radical depolymerization and liquid chromatography-mass spectrometry. Anal Chem 2013; 86:326-30. [PMID: 24364596 DOI: 10.1021/ac403625a] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Heparin is a critically important anticoagulant drug that was contaminated with a persulfonated polysaccharide in 2008, resulting in a number of severe adverse reactions, some leading to death. Controversy remains as to the precise composition of the 2008 contaminant, and new information suggests that heparin may now be subject to adulteration with a new, difficult to detect, contaminant, N-sulfo oversulfated chondroitin sulfate. This study synthesizes this new potential contaminant and describes the use of radical depolymerization followed by liquid chromatography-mass spectrometry to detect N-sulfo oversulfated chondroitin sulfate and to confirm the structure of the 2008 contaminant as oversulfated chondroitin sulfate and not oversulfated heparan sulfate.
Collapse
Affiliation(s)
- Guoyun Li
- College of Food Science and Technology, Ocean University of China , Qingdao, Shandong 266003, China
| | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Wuethrich A, Haddad PR, Quirino JP. Chiral capillary electromigration techniques-mass spectrometry-hope and promise. Electrophoresis 2013; 35:2-11. [PMID: 24265218 DOI: 10.1002/elps.201300377] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2013] [Revised: 10/06/2013] [Accepted: 10/07/2013] [Indexed: 11/09/2022]
Abstract
Analytical methods for chiral compounds require a separation step prior to mass spectrometric detection. CE can separate enantiomers by the use of a chiral selector and can be hyphenated with MS. The chiral selector can be either embedded inside the capillary (electrochromatography) or added into the background solution (EKC). This review describes the fundamentals and highlights the recent developments (September 2009-May 2013) of chiral CEC and EKC with detection using MS. There were 20 research and more than 30 review papers during this period. The research efforts were driven by fundamental studies, such as the development of novel chiral selectors in electrochromatography and of advanced partial filling techniques in EKC in order to optimise separation. Other developments were in application studies, such as in food analytics and metabolomics.
Collapse
Affiliation(s)
- Alain Wuethrich
- Australian Centre for Research on Separation Science (ACROSS), School of Chemistry, University of Tasmania, Hobart, Australia
| | | | | |
Collapse
|
11
|
Abstract
Capillary electrophoresis (CE) has matured to one of the major liquid phase enantiodifferentiation techniques since the first report in 1985. This can be primarily attributed to the flexibility as well as the various modes available including electrokinetic chromatography (EKC), micellar electrokinetic chromatography (MEKC), and microemulsion electrokinetic chromatography (MEEKC). In contrast to chromatographic techniques, the chiral selector is mobile in the background electrolyte. Furthermore, a large variety of chiral selectors are available that can be easily combined in the same separation system. In addition, the migration order of the enantiomers can be adjusted by a number of approaches. In CE enantiodifferentiations the separation principle is comparable to chromatography while the principle of the movement of the analytes in the capillary is based on electrophoretic phenomena. The present chapter will focus on mechanistic aspects of CE enantioseparations including enantiomer migration order and the current understanding of selector-selectand structures. Selected examples of the basic enantioseparation modes EKC, MEKC, and MEEKC will be discussed.
Collapse
Affiliation(s)
- Gerhard K E Scriba
- Department of Pharmaceutical/Medicinal Chemistry, Friedrich Schiller University Jena, Philosophenweg 14, 07743, Jena, Germany,
| |
Collapse
|
12
|
Silva M. Micellar electrokinetic chromatography: A review of methodological and instrumental innovations focusing on practical aspects. Electrophoresis 2012; 34:141-58. [DOI: 10.1002/elps.201200349] [Citation(s) in RCA: 78] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2012] [Revised: 07/25/2012] [Accepted: 07/25/2012] [Indexed: 12/20/2022]
Affiliation(s)
- Manuel Silva
- Department of Analytical Chemistry, Rabanales Campus; University of Cordoba; Cordoba; Spain
| |
Collapse
|
13
|
Zhao SS, Zhong X, Tie C, Chen DD. Capillary electrophoresis-mass spectrometry for analysis of complex samples. Proteomics 2012; 12:2991-3012. [DOI: 10.1002/pmic.201200221] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2012] [Revised: 07/10/2012] [Accepted: 07/18/2012] [Indexed: 12/20/2022]
Affiliation(s)
- Shuai Sherry Zhao
- Department of Chemistry; University of British Columbia; Vancouver BC Canada
| | - Xuefei Zhong
- Department of Chemistry; University of British Columbia; Vancouver BC Canada
| | - Cai Tie
- Department of Chemistry; University of British Columbia; Vancouver BC Canada
| | - David D.Y. Chen
- Department of Chemistry; University of British Columbia; Vancouver BC Canada
| |
Collapse
|
14
|
Krenkova J, Foret F. On-line CE/ESI/MS interfacing: recent developments and applications in proteomics. Proteomics 2012; 12:2978-90. [PMID: 22888067 DOI: 10.1002/pmic.201200140] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2012] [Revised: 05/17/2012] [Accepted: 06/12/2012] [Indexed: 12/13/2022]
Abstract
After shining as the ultimate separation - sequencing technique used for the successful completion of the Human Genome Project, in the early 2000s CE experienced lowered popularity among separation scientists. The renewed interest in recent years relates to the separation needs, especially in proteomics, metabolomics, and glycomics, where CE complements liquid chromatography techniques. This interest is further boosted by the regulators requiring additional separation techniques for characterization of newly developed pharmaceuticals. This paper gives a short overview of recent developments in the on-line interfacing of CE separation techniques with electrospray ionization/mass spectrometric analysis. Both the instrumentation and selected CE/ESI/MS applications including analyses of peptides, proteins, and glycans are discussed with the stress on research published in the past 3 years. Techniques related to the proteomic and glycomic analyses such as sample preconcentration, on-line protein digestion, and analyte derivatization prior CE/ESI/MS analysis are also included.
Collapse
Affiliation(s)
- Jana Krenkova
- Institute of Analytical Chemistry of the ASCR, Brno, Czech Republic.
| | | |
Collapse
|
15
|
Moreno-González D, Gámiz-Gracia L, Bosque-Sendra JM, García-Campaña AM. Dispersive liquid–liquid microextraction using a low density extraction solvent for the determination of 17 N-methylcarbamates by micellar electrokinetic chromatography–electrospray–mass spectrometry employing a volatile surfactant. J Chromatogr A 2012; 1247:26-34. [DOI: 10.1016/j.chroma.2012.05.048] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2012] [Revised: 05/10/2012] [Accepted: 05/12/2012] [Indexed: 10/28/2022]
|
16
|
Carbon nanotubes in capillary electrophoresis, capillary electrochromatography and microchip electrophoresis. OPEN CHEM 2012. [DOI: 10.2478/s11532-012-0014-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
Abstract
AbstractCarbon nanotubes are among the plethora of novel nanostructures developed since the 1980s. Nanotubes have attracted considerable interest by the scientific community thanks to their extraordinary physical and chemical properties. Research areas have flourished in recent years and now include the nano-electronic, (bio)sensor and analytical field along with many others. This review covers applications of carbon nanotubes in capillary electrophoresis, capillary electrochromatography and microchip electrophoresis. First, carbon nanotubes and a range of electrophoretic techniques are briefly introduced and key references are mentioned. Next, a comprehensive survey of achievements in the field is presented and critically assessed. The merits and downsides of carbon nanotube addition to the various capillary electrophoretic modes are addressed. The different schemes for fabricating electrochromatographic stationary phases based on carbon nanotubes are discussed. Finally, some future perspectives are offered.
Collapse
|
17
|
Hung SH, Cheng WS, Huang JL, Wang CW, Her GR. Chiral electrokinetic chromatography-electrospray ionization-mass spectrometry using a double junction interface. Electrophoresis 2012; 33:546-51. [DOI: 10.1002/elps.201100384] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
18
|
Fukuji TS, Castro-Puyana M, Tavares MFM, Cifuentes A. Sensitive and fast determination of Sudan dyes in chilli powder by partial-filling micellar electrokinetic chromatography-tandem mass spectrometry. Electrophoresis 2012; 33:705-12. [DOI: 10.1002/elps.201100272] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
|
19
|
Espada A, Molina-Martin M. Capillary electrophoresis and small molecule drug discovery: a perfect match? Drug Discov Today 2012; 17:396-404. [PMID: 22387356 DOI: 10.1016/j.drudis.2012.02.008] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2011] [Revised: 12/19/2011] [Accepted: 02/10/2012] [Indexed: 01/27/2023]
Abstract
Capillary electrophoresis (CE) is an analytical technique based on the separation of the analytes within a capillary owing to their different electrophoretic mobilities. It is widely used in pharmaceutical analyses owing to its versatility and high separation power. However, its penetration into the drug discovery scene has been relatively limited until recent years. Several factors have contributed to this low implementation, including the maturity of liquid chromatography, the scarcity of experienced CE practitioners, and certain limitations intrinsic to the technique. Recently, instrumental improvements and the growing demand for analytical information have lead to a continuously expanding range of routine electrophoretic applications throughout pharmaceutical discovery and development. In this article we review CE fundamentals, review well-established CE methodologies in drug discovery of small molecules and discuss trends that, in our opinion, might emerge in the coming years.
Collapse
Affiliation(s)
- Alfonso Espada
- Analytical Technologies Department, Centro de Investigación Lilly SA, Avda de la Industria 30, 28108-Alcobendas, Madrid, Spain
| | | |
Collapse
|
20
|
Stanley B, Lucy CA. Micellar electrokinetic chromatography with acid labile surfactant. J Chromatogr A 2012; 1226:55-60. [DOI: 10.1016/j.chroma.2011.09.065] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2011] [Revised: 09/23/2011] [Accepted: 09/23/2011] [Indexed: 01/12/2023]
|
21
|
Rabanes HR, Guidote AM, Quirino JP. Capillary electrophoresis of natural products: Highlights of the last five years (2006-2010). Electrophoresis 2011; 33:180-95. [DOI: 10.1002/elps.201100223] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2011] [Revised: 09/22/2011] [Accepted: 09/22/2011] [Indexed: 12/14/2022]
|
22
|
Sánchez-Hernández L, Castro-Puyana M, Marina ML, Crego AL. Recent approaches in sensitive enantioseparations by CE. Electrophoresis 2011; 33:228-42. [PMID: 22144098 DOI: 10.1002/elps.201100404] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2011] [Revised: 09/16/2011] [Accepted: 09/17/2011] [Indexed: 12/27/2022]
Abstract
The latest strategies and instrumental improvements for enhancing the detection sensitivity in chiral analysis by CE are reviewed in this work. Following the previous reviews by García-Ruiz et al. (Electrophoresis 2006, 27, 195-212) and Sánchez-Hernández et al. (Electrophoresis 2008, 29, 237-251; Electrophoresis 2010, 31, 28-43), this review includes those papers that were published during the period from June 2009 to May 2011. These works describe the use of offline and online sample treatment techniques, online sample preconcentration techniques based on electrophoretic principles, and alternative detection systems to UV-Vis to increase the detection sensitivity. The application of the above-mentioned strategies, either alone or combined, to improve the sensitivity in the enantiomeric analysis of a broad range of samples, such as pharmaceutical, biological, food and environmental samples, enables to decrease the limits of detection up to 10⁻¹² M. The use of microchips to achieve sensitive chiral separations is also discussed.
Collapse
Affiliation(s)
- Laura Sánchez-Hernández
- Department of Analytical Chemistry, Faculty of Chemistry, University of Alcalá. Ctra. Madrid-Barcelona, Alcalá de Henares, Madrid, Spain
| | | | | | | |
Collapse
|
23
|
Kašička V. Recent developments in CE and CEC of peptides (2009-2011). Electrophoresis 2011; 33:48-73. [DOI: 10.1002/elps.201100419] [Citation(s) in RCA: 95] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2011] [Revised: 09/19/2011] [Accepted: 09/20/2011] [Indexed: 12/12/2022]
|
24
|
Huang JL, Li FA, Her GR. A comparative study of interfaces for microchip micellar electrokinetic chromatography-electrospray ionization mass spectrometry using the surfactant ammonium dodecyl sulfate. Electrophoresis 2011; 32:3385-91. [DOI: 10.1002/elps.201100288] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2011] [Revised: 07/18/2011] [Accepted: 08/01/2011] [Indexed: 11/10/2022]
|
25
|
Han Y, Bai Y, Xiao Y, Du F, Liang Y, Tan Z, Zhao M, Liu H. Simultaneous discrimination of jasmonic acid stereoisomers by CE-QTOF-MS employing the partial filling technique. Electrophoresis 2011; 32:2693-9. [PMID: 21910130 DOI: 10.1002/elps.201100043] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2011] [Revised: 03/22/2011] [Accepted: 03/31/2011] [Indexed: 11/10/2022]
Abstract
Jasmonic acid (JA), an essential plant hormone controlling the plant defense signaling system and developmental processes, has stereospecific bioactivities that have not been well understood mainly due to the limitation in separation and detection methodologies. In this work, a fast CE-UV method based on short-end injection technique and a sensitive CE-QTOF-MS method based on partial filling technique were successfully developed for the enantioseparation of racemic JA. The successive coating technique was also involved by modifying the capillary with multiple ionic polymer layers of polybrene-dextran sulfate-polybrene. This was the first report on the direct resolution of both pairs of JA enantiomers, including two naturally occurring JA stereoisomers. Although no pure JA stereoisomers were commercially available, all the separated JA stereoisomers were identified indirectly by comparing the difference between the racemic standard and plant samples based on the presence and the ratio of each stereoisomer. Satisfactory results were obtained in terms of sensitivity (LOD, 24 ng/mL or 0.7 fmol for single JA stereoisomer) using 45 mmol/L ammonium acetate at pH 4.5 containing 70 mmol/L α-CD as the buffer system. This established CE-QTOF-MS method was later successfully applied for the study of the naturally occurring JA stereoisomers in wounded tobacco leaves.
Collapse
Affiliation(s)
- Yehua Han
- Beijing National Laboratory for Molecular Sciences, Institute of Analytical Chemistry, College of Chemistry and Molecular Engineering, Peking University, Beijing, P. R. China
| | | | | | | | | | | | | | | |
Collapse
|
26
|
Affiliation(s)
- R. K. Gilpin
- Department of Chemistry, Wright State University, Dayton, Ohio 45435, United States
| | - C. S. Gilpin
- Select-O-Sep, LLC, 111 West Main Street, Freeport, Ohio 43973, United States
| |
Collapse
|
27
|
Pantůčková P, Gebauer P, Boček P, Křivánková L. Recent advances in CE-MS: Synergy of wet chemistry and instrumentation innovations. Electrophoresis 2010; 32:43-51. [PMID: 21171112 DOI: 10.1002/elps.201000382] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2010] [Revised: 08/17/2010] [Accepted: 08/17/2010] [Indexed: 01/29/2023]
Abstract
CE with MS detection is a hyphenated technique which greatly improves the ability of CE to deal with real samples, especially with those coming from biology and medicine, where the target analytes are present as trace amounts in very complex matrices. CE-MS is now almost a routine technique performed on commercially available instruments. It faces currently a tremendous development of the technique itself as well as of its wide application area. Great interest in CE-MS is reflected in the scientific literature by many original research articles and also by numerous reviews. The review presented here has a general scope and belongs to a series of regularly published reviews on the topic. It covers the literature from the last 2 years, since January 2008 till June 2010. It brings a critical selection of related literature sorted into groups reflecting the main topics of actual scientific interest: (i) innovations in CE-ESI-MS, (ii) use of alternative interfaces, and (iii) ways to enhance sensitivity. Special attention is paid to novel electrolyte systems amenable to CE-MS including nonvolatile BGEs, to advanced CE separation principles such as MEKC, MEEKC, chiral CE, and to the use of preconcentration techniques.
Collapse
Affiliation(s)
- Pavla Pantůčková
- Institute of Analytical Chemistry of the Academy of Sciences of the Czech Republic, Brno, Czech Republic
| | | | | | | |
Collapse
|