1
|
Favilli L, Giacomino A, Malandrino M, Inaudi P, Diana A, Abollino O. Strategies for mercury speciation with single and multi-element approaches by HPLC-ICP-MS. Front Chem 2022; 10:1082956. [PMID: 36531326 PMCID: PMC9754325 DOI: 10.3389/fchem.2022.1082956] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Accepted: 11/18/2022] [Indexed: 08/21/2023] Open
Abstract
Mercury (Hg) and its compounds are highly toxic for humans and ecosystems, and their chemical forms determine both their behavior and transportation as well as their potential toxicity for human beings. Determining the various species of an element is therefore more crucial than understanding its overall concentration in samples. For this reason, several studies focus on the development of new analytical techniques for the identification, characterization, and quantification of Hg compounds. Commercially available, hyphenated technology, such as HPLC-ICP-MS, supports the rapid growth of speciation analysis. This review aims to summarize and critically examine different approaches for the quantification of mercury species in different samples using HPLC-ICP-MS. The steps preceding the quantification of the analyte, namely sampling and pretreatment, will also be addressed. The scenarios evaluated comprehend single and multi-element speciation analysis to create a complete guide about mercury content quantification.
Collapse
Affiliation(s)
- Laura Favilli
- Department of Drug Science and Technology, University of Torino, Turin, Italy
| | - Agnese Giacomino
- Department of Drug Science and Technology, University of Torino, Turin, Italy
| | - Mery Malandrino
- Department of Chemistry, University of Torino, Torino, Italy
| | - Paolo Inaudi
- Department of Drug Science and Technology, University of Torino, Turin, Italy
| | - Aleandro Diana
- Department of Chemistry, University of Torino, Torino, Italy
| | - Ornella Abollino
- Department of Drug Science and Technology, University of Torino, Turin, Italy
| |
Collapse
|
2
|
Proch J, Niedzielski P. Multi-mode Sample Introduction System (MSIS) as an interface in the hyphenated system 2 HPLC-MSIS-ICP-OES in simultaneous determination of metals and metalloids species. Anal Chim Acta 2021; 1147:1-14. [PMID: 33485568 DOI: 10.1016/j.aca.2020.12.047] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2020] [Revised: 11/10/2020] [Accepted: 12/23/2020] [Indexed: 12/29/2022]
Abstract
The paper presents a usage of a new hyphenated technique, wherein a Multi-mode Sample Introduction System (MSIS) was applied as an interface of two high pressure liquid chromatography units and inductively coupled plasma optical emission spectrometry (2 HPLC-MSIS-ICP-OES). Simultaneous separation and detection of non-hydride forming and hydride forming elements was possible due to the application of two different HPLC column, cation-exchange and anion-exchange respectively. The method was able to determine 15 elements quantitatively with a distinction of three arsenic and two iron species and it was validated obtaining acceptable LODs (2.67-28.7 μg L-1) and recoveries (80-120%). The method applicability was presented and confirmed on 5 varied sample matrix types i.e. post-glacial sediments, yerba mate (Ilex paraguariensis), soil samples located in the proximity of industry wastes disposal site, river sediments, and archaeological pottery. In addition to the above, unknown Cu, Fe, Mn and Zn species were detected in real samples (qualitative speciation analysis) and the identification was attempted according to the literature.
Collapse
Affiliation(s)
- Jędrzej Proch
- Adam Mickiewicz University, Faculty of Chemistry, Department of Analytical Chemistry, Uniwersytetu Poznańskiego 8, 61-614, Poznań, Poland
| | - Przemysław Niedzielski
- Adam Mickiewicz University, Faculty of Chemistry, Department of Analytical Chemistry, Uniwersytetu Poznańskiego 8, 61-614, Poznań, Poland.
| |
Collapse
|
3
|
Zhong XL, Wen SH, Wang Y, Luo YX, Li ZM, Liang RP, Zhang L, Qiu JD. Colorimetric and electrochemical arsenate assays by exploiting the peroxidase-like activity of FeOOH nanorods. Mikrochim Acta 2019; 186:732. [PMID: 31667627 DOI: 10.1007/s00604-019-3863-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2019] [Accepted: 09/19/2019] [Indexed: 01/07/2023]
Abstract
The authors describe an electrochemical and an optical method for the determination of As(V) by using iron oxyhydroxide (FeOOH) nanorods that display peroxidase-mimicking activity. The nanorods catalyze the oxidation of substrate ABTS by H2O2 to form a green product with an absorption maximum at 418 nm. If, however, As(V) is electrostatically adsorbed on the nanorods, the oxidation is gradually inhibited. A colorimetric assay was worked out based on these findings. Response is linear in the 0 to 8 ppb and 8 to 200 ppb As(V) concentration range, and the detection limit is 0.1 ppb. Even higher sensitivity is achieved in an electrochemical method which is based on the excellent electrical conductivity of FeOOH nanorods. Electrochemical analysis of As(V) was achieved by first adsorbing As(V) on the nanorods. This inhibits the ABTS reduction current signal, best measured at a potential of 150 mV (vs. Ag/AgCl). The linear range extends from 0.04 to 200 ppb, and the detection limit is as low as 12 ppt. Graphical abstract Schematic representation of FeOOH nanorod-based colorimetric and electrochemical assays for arsenate (As(V)). As(V) adsorbed on FeOOH nanorods inhibits the peroxidase-mimicking activity of nanorods, and a colorimetric and electrochemical dual-signal assay was constructed to achieve sensitive determination of As(V).
Collapse
Affiliation(s)
- Xiao-Li Zhong
- College of Chemistry, Nanchang University, Nanchang, 330031, China
| | - Shao-Hua Wen
- College of Chemistry, Nanchang University, Nanchang, 330031, China
| | - Yi Wang
- College of Chemistry, Nanchang University, Nanchang, 330031, China
| | - Yu-Xi Luo
- College of Chemistry, Nanchang University, Nanchang, 330031, China
| | - Zhi-Mei Li
- College of Chemistry, Nanchang University, Nanchang, 330031, China
| | - Ru-Ping Liang
- College of Chemistry, Nanchang University, Nanchang, 330031, China
| | - Li Zhang
- College of Chemistry, Nanchang University, Nanchang, 330031, China
| | - Jian-Ding Qiu
- College of Chemistry, Nanchang University, Nanchang, 330031, China. .,Engineering Technology Research Center for Environmental Protection Materials and Equipment of Jiangxi Province, Pingxiang University, Pingxiang, 337055, China.
| |
Collapse
|
4
|
Enzyme-assisted extraction and liquid chromatography-inductively coupled plasma mass spectrometry for the determination of arsenic species in fish. J Chromatogr A 2018; 1573:48-58. [PMID: 30195857 DOI: 10.1016/j.chroma.2018.08.068] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2018] [Revised: 08/28/2018] [Accepted: 08/31/2018] [Indexed: 02/05/2023]
Abstract
A sensitive, simple and rapid method for the simultaneous determination of eleven arsenic species has been developed. A high performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICP-MS) technique was used for the analysis of eleven arsenic species in less than 17 min. Different extraction solutions were explored and the recovery results using water and aqueous acidic solvents, aqueous organic solvents and enzymes showed that 40 mg protease with 0.75 mL 0.5% hydrochloric acid (v/v) as the extraction agent gave the best experimental results. Species separation with ammonium carbonate solution as the mobile phase was conducted on an anion-exchange chromatographic column using gradient elution. The column temperature was 20 °C and kinetic energy discrimination (KED) was employed to eliminate spectral interference. The use of KED mode effectively removed interference from 75ArCl. The detection limit (LD) of the method was in the range of 0.11-0.59 μg kg-1. Repeatability values obtained for spiked real fish samples were in the range of 1.1%-7.6%. Accuracy was calculated based on the analysis of spiked real fish samples at five concentration levels. Obtained recoveries were 91%-106%. The validated method was used in a pilot study to analyze real samples of fish, the organic arsenic especially AsB was the major arsenic specie present in the analyzed samples, only trace amount of inorganic arsenic were detected. The analytical method should improve the assessment of human exposure associated with arsenic intake from fish.
Collapse
|
5
|
Séby F, Vacchina V. Critical assessment of hexavalent chromium species from different solid environmental, industrial and food matrices. Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2017.11.019] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
6
|
Sadiq NW, Beauchemin D. Simultaneous Speciation Analysis of Arsenic, Chromium, and Selenium in the Bioaccessible Fraction for Realistic Risk Assessment of Food Safety. Anal Chem 2017; 89:13299-13304. [PMID: 29151347 DOI: 10.1021/acs.analchem.7b03423] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
A simple and fast method was developed for risk assessment of As, Cr, and Se in food, which is demonstrated here using three cooked and uncooked rice samples (basmati as well as organic white and brown rice). The bioaccessible fraction was first determined through online leaching of rice minicolumns (maintained at 37 °C) sequentially with artificial saliva, gastric juice, and intestinal juice while continuously monitoring potentially toxic elements (As, Cr, and Se) by inductively coupled plasma mass spectrometry (ICPMS). Then, a new ion chromatography method with online detection by ICPMS was developed for the simultaneous speciation analysis of As, Cr, and Se in the bioaccessible fraction to determine the portion of these elements that was actually toxic. Using gradient elution, four As species [As(III), As(V), monomethylarsonic acid, and dimethylarsinic acid], two Cr species [Cr(III) and Cr(VI)], and two Se species [Se(IV) and Se(VI)] were separated within 12 min. The simultaneous speciation analysis of As, Cr, and Se revealed that the simple act of cooking can convert all of the carcinogenic Cr(VI) to the safer Cr(III).
Collapse
Affiliation(s)
- Nausheen W Sadiq
- Department of Chemistry, Queen's University , 90 Bader Lane, Kingston, Ontario K7L3N6, Canada
| | - Diane Beauchemin
- Department of Chemistry, Queen's University , 90 Bader Lane, Kingston, Ontario K7L3N6, Canada
| |
Collapse
|
7
|
Engelsen CJ, van der Sloot HA, Petkovic G. Long-term leaching from recycled concrete aggregates applied as sub-base material in road construction. THE SCIENCE OF THE TOTAL ENVIRONMENT 2017; 587-588:94-101. [PMID: 28238429 DOI: 10.1016/j.scitotenv.2017.02.052] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2016] [Revised: 02/06/2017] [Accepted: 02/06/2017] [Indexed: 06/06/2023]
Abstract
In the present study, the metal leaching from recycled concrete aggregates (RCA) used in road sub-base is presented after >10years of exposure. The released levels of inorganic constituents, the effect of small variation of pH and the use of de-icing salt during winter season were studied. In addition, speciation modelling for the major elements has been provided. The pH varied from 7.5 to 8.5 for the sub-base constructed with RCA whereas the pH of around 8 was obtained for the test section not affected by the traffic and de-icing salts. Despite a small variation in pH, the leachability of Al, Ca and Mg was found to be strongly dependent on pH and fair agreement between the measured and predicted concentrations was obtained. The speciation modelling indicated that gibbsite, calcite and magnesite controlled the solubility of Al, Ca and Mg, respectively, which was in agreement with the expected carbonation products. Due to the larger pH fluctuations in the test sections exposed to the road traffic, increased concentrations were observed for the oxyanions. The same effect was not seen for the trace metal cations Cd, Cu, Ni, Pb and Zn. The distinct pH dependent leaching profile (solubility maximum in the mildly basic pH region) for vanadium could be seen after 10years of exposure. The simplified risk assessment showed that the released quantities did not exceed the chosen acceptance criteria for groundwater and fresh water. The results obtained for the test section not influenced by road dust and de-icing salts, complied with these criteria even without considering any dilution effects caused by the mixing of pore water with groundwater.
Collapse
Affiliation(s)
- Christian J Engelsen
- SINTEF Building and Infrastructure, PO Box 124, Blindern, NO-0314, Oslo, Norway.
| | - Hans A van der Sloot
- Hans van der Sloot Consultancy, Dorpsstraat 216, 1721 BV Langedijk, The Netherlands.
| | - Gordana Petkovic
- Norwegian Public Roads Administration, PO Box 8142 Dep, NO-0033 Oslo, Norway.
| |
Collapse
|
8
|
Jia X, Gong D, Wang J, Huang F, Duan T, Zhang X. Arsenic speciation in environmental waters by a new specific phosphine modified polymer microsphere preconcentration and HPLC–ICP-MS determination. Talanta 2016; 160:437-443. [DOI: 10.1016/j.talanta.2016.07.050] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2016] [Revised: 07/20/2016] [Accepted: 07/23/2016] [Indexed: 10/21/2022]
|
9
|
Marcinkowska M, Barałkiewicz D. Multielemental speciation analysis by advanced hyphenated technique - HPLC/ICP-MS: A review. Talanta 2016; 161:177-204. [PMID: 27769396 DOI: 10.1016/j.talanta.2016.08.034] [Citation(s) in RCA: 72] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2016] [Revised: 08/08/2016] [Accepted: 08/11/2016] [Indexed: 01/24/2023]
Abstract
Speciation analysis has become an invaluable tool in human health risk assessment, environmental monitoring or food quality control. Another step is to develop reliable multielemental speciation methodologies, to reduce costs, waste and time needed for the analysis. Separation and detection of species of several elements in a single analytical run can be accomplished by high performance liquid chromatography hyphenated to inductively coupled plasma mass spectrometry (HPLC/ICP-MS). Our review assembles articles concerning multielemental speciation determination of: As, Se, Cr, Sb, I, Br, Pb, Hg, V, Mo, Te, Tl, Cd and W in environmental, biological, food and clinical samples analyzed with HPLC/ICP-MS. It addresses the procedures in terms of following issues: sample collection and pretreatment, selection of optimal conditions for elements species separation by HPLC and determination using ICP-MS as well as metrological approach. The presented work is the first review article concerning multielemental speciation analysis by advanced hyphenated technique HPLC/ICP-MS.
Collapse
Affiliation(s)
- Monika Marcinkowska
- Department of Trace Element Analysis by Spectroscopy Method, Faculty of Chemistry, Adam Mickiewicz University in Poznań, 89b Umultowska Street, 61-614 Poznań, Poland
| | - Danuta Barałkiewicz
- Department of Trace Element Analysis by Spectroscopy Method, Faculty of Chemistry, Adam Mickiewicz University in Poznań, 89b Umultowska Street, 61-614 Poznań, Poland.
| |
Collapse
|
10
|
Optimization of arsenic extraction in rice samples by Plackett–Burman design and response surface methodology. Food Chem 2016; 204:283-288. [DOI: 10.1016/j.foodchem.2016.02.126] [Citation(s) in RCA: 50] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2015] [Revised: 02/15/2016] [Accepted: 02/20/2016] [Indexed: 11/19/2022]
|
11
|
Marcinkowska M, Komorowicz I, Barałkiewicz D. New procedure for multielemental speciation analysis of five toxic species: As(III), As(V), Cr(VI), Sb(III) and Sb(V) in drinking water samples by advanced hyphenated technique HPLC/ICP-DRC-MS. Anal Chim Acta 2016; 920:102-11. [PMID: 27114229 DOI: 10.1016/j.aca.2016.03.039] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2015] [Revised: 03/09/2016] [Accepted: 03/18/2016] [Indexed: 11/16/2022]
Abstract
Analytical procedure dedicated for multielemental determination of toxic species: As(III), As(V), Cr(VI), Sb(III) and Sb(V) in drinking water samples using high performance liquid chromatography hyphenated to inductively coupled plasma mass spectrometry (HPLC/ICP-DRC-MS) technique was developed. Optimization of the detection and separation conditions was conducted. Dynamic reaction cell (DRC) with oxygen as a reaction gas was involved in the experiments. Obtained analytical signals for species separation were symmetrical, as studied by anion-exchange chromatography. Applied mobile phase consisted of 3 mM of EDTANa2 and 36 mM of ammonium nitrate. Full separation of species in the form of the following forms: H3AsO3, H2AsO4(-), SbO2(-), Sb(OH)6(-), CrO4(2-) was achieved in 15 min with use of gradient elution program. Detailed validation of analytical procedure proved the reliability of analytical measurements. The procedure was characterized by high precision in the range from 1.7% to 2.4%. Detection limits (LD) were 0.067 μg L(-1), 0.068 μg L(-1), 0.098 μg L(-1), 0.083 μg L(-1) and 0.038 μg L(-1) for As(III), As(V), Cr(VI), Sb(III) and Sb(V), respectively. Obtained recoveries confirmed the lack of interferences' influence on analytical signals as their values were in the range of 91%-110%. The applicability of the proposed procedure was tested on drinking water samples characterized by mineralization up to 650 mg L(-1).
Collapse
Affiliation(s)
- Monika Marcinkowska
- Department of Trace Element Analysis by Spectroscopy Method, Faculty of Chemistry, Adam Mickiewicz University in Poznań, 89b Umultowska Street, 61-614, Poznań, Poland
| | - Izabela Komorowicz
- Department of Trace Element Analysis by Spectroscopy Method, Faculty of Chemistry, Adam Mickiewicz University in Poznań, 89b Umultowska Street, 61-614, Poznań, Poland
| | - Danuta Barałkiewicz
- Department of Trace Element Analysis by Spectroscopy Method, Faculty of Chemistry, Adam Mickiewicz University in Poznań, 89b Umultowska Street, 61-614, Poznań, Poland.
| |
Collapse
|
12
|
Study on multielemental speciation analysis of Cr(VI), As(III) and As(V) in water by advanced hyphenated technique HPLC/ICP-DRC-MS. Fast and reliable procedures. Talanta 2015; 144:233-40. [DOI: 10.1016/j.talanta.2015.04.087] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2015] [Revised: 04/24/2015] [Accepted: 04/30/2015] [Indexed: 11/17/2022]
|
13
|
Sun J, Ma L, Yang Z, Wang L. Optimization of species stability and interconversion during the complexing reaction for chromium speciation by high-performance liquid chromatography with inductively coupled plasma mass spectrometry. J Sep Sci 2014; 37:1944-50. [DOI: 10.1002/jssc.201400170] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2014] [Revised: 04/05/2014] [Accepted: 04/25/2014] [Indexed: 11/11/2022]
Affiliation(s)
- Jing Sun
- College of Chemistry & Chemical Engineering; Central South University; Changsha China
| | - Li Ma
- College of Chemistry & Chemical Engineering; Central South University; Changsha China
| | - Zhaoguang Yang
- College of Chemistry & Chemical Engineering; Central South University; Changsha China
| | - Lin Wang
- College of Chemistry & Chemical Engineering; Central South University; Changsha China
| |
Collapse
|
14
|
Wolle MM, Fahrenholz T, Rahman GMM, Pamuku M, Kingston HM'S, Browne D. Method development for the redox speciation analysis of iron by ion chromatography-inductively coupled plasma mass spectrometry and carryover assessment using isotopically labeled analyte analogues. J Chromatogr A 2014; 1347:96-103. [PMID: 24819017 DOI: 10.1016/j.chroma.2014.04.066] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2014] [Revised: 04/03/2014] [Accepted: 04/22/2014] [Indexed: 11/24/2022]
Abstract
An ion chromatography-inductively coupled plasma mass spectrometry (IC-ICP-MS) method was developed for the redox speciation analysis of iron (Fe) based on in-column complexation of Fe(2+) and Fe(3+) by dipicolinic acid (DPA). The effects of column type, mobile phase composition and molecular ion interference were studied in the method optimization. The carryover of the target species in the IC-ICP-MS method was uniquely and effectively evaluated using isotopically enriched analogues of the analytes ((54)Fe(2+) and (57)Fe(3+)). Standard solutions of the enriched standards were injected into the system following analysis of a sample, and the ratios of the isotopes of iron in the enriched standards were calculated based on the chromatographic peak areas. The concentrations of the analytes carried over from the sample to the enriched standards were determined using the quantitative relationship in isotope dilution mass spectrometry (IDMS). In contrast to the routine way of evaluating carryover effect by injecting a blank solution after sample analysis, the use of isotopically enriched standards identified significant analyte carryover in the present method. Extensive experiments were carried out to systematically identify the source of the carryover and to eliminate the problem; the separation column was found to be the exclusive source. More than 95% of the analyte carryover was eliminated by reducing the length of the column. The detection limit of the IC-ICP-MS method (MDL) for the iron species was 2ngg(-1). The method was used to determine Fe(2+) and Fe(3+) in synthetic aqueous standard solutions and a beverage sample.
Collapse
Affiliation(s)
- Mesay Mulugeta Wolle
- Department of Chemistry and Biochemistry, Duquesne University, 600 Forbes Avenue, Pittsburgh, PA 15282, USA.
| | - Timothy Fahrenholz
- Applied Isotope Technologies, 2403 Sidney Street Suite 280, Pittsburgh, PA 15203, USA
| | - G M Mizanur Rahman
- Applied Isotope Technologies, 2403 Sidney Street Suite 280, Pittsburgh, PA 15203, USA
| | - Matt Pamuku
- Applied Isotope Technologies, 2403 Sidney Street Suite 280, Pittsburgh, PA 15203, USA
| | - H M 'Skip' Kingston
- Department of Chemistry and Biochemistry, Duquesne University, 600 Forbes Avenue, Pittsburgh, PA 15282, USA
| | - Damien Browne
- Pepsico International, Little Island Business Park, Little Island, Co., Cork, Ireland
| |
Collapse
|
15
|
Wolle MM, Rahman GM, ‘Skip’ Kingston H, Pamuku M. Speciation analysis of arsenic in prenatal and children's dietary supplements using microwave-enhanced extraction and ion chromatography–inductively coupled plasma mass spectrometry. Anal Chim Acta 2014; 818:23-31. [DOI: 10.1016/j.aca.2014.01.060] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2013] [Revised: 01/23/2014] [Accepted: 01/30/2014] [Indexed: 10/25/2022]
|
16
|
Shih TT, Lin CH, Hsu IH, Chen JY, Sun YC. Development of a Titanium Dioxide-Coated Microfluidic-Based Photocatalyst-Assisted Reduction Device to Couple High-Performance Liquid Chromatography with Inductively Coupled Plasma-Mass Spectrometry for Determination of Inorganic Selenium Species. Anal Chem 2013; 85:10091-8. [DOI: 10.1021/ac400934e] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Tsung-Ting Shih
- Department
of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, 30013 Hisnchu, Taiwan
| | - Cheng-Hsing Lin
- Department
of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, 30013 Hisnchu, Taiwan
| | - I-Hsiang Hsu
- Center for Measurement Standards, Industrial Technology Research Institute, 30011 Hsinchu, Taiwan
| | - Jian-Yi Chen
- Department
of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, 30013 Hisnchu, Taiwan
| | - Yuh-Chang Sun
- Department
of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, 30013 Hisnchu, Taiwan
| |
Collapse
|
17
|
Development of chip-based photocatalyst-assisted reduction device to couple high performance liquid chromatography and inductively coupled plasma-mass spectrometry for determination of inorganic selenium species. J Chromatogr A 2013; 1304:101-8. [DOI: 10.1016/j.chroma.2013.06.067] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2013] [Revised: 06/11/2013] [Accepted: 06/26/2013] [Indexed: 02/07/2023]
|
18
|
Engelsen CJ, Wibetoe G, van der Sloot HA, Lund W, Petkovic G. Field site leaching from recycled concrete aggregates applied as sub-base material in road construction. THE SCIENCE OF THE TOTAL ENVIRONMENT 2012; 427-428:86-97. [PMID: 22554532 DOI: 10.1016/j.scitotenv.2012.04.021] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2011] [Revised: 04/06/2012] [Accepted: 04/07/2012] [Indexed: 05/31/2023]
Abstract
The release of major and trace elements from recycled concrete aggregates used in an asphalt covered road sub-base has been monitored for more than 4 years. A similar test field without an asphalt cover, directly exposed to air and rain, and an asphalt covered reference field with natural aggregates in the sub-base were also included in the study. It was found that the pH of the infiltration water from the road sub-base with asphalt covered concrete aggregates decreased from 12.6 to below pH 10 after 2.5 years of exposure, whereas this pH was reached within only one year for the uncovered field. Vertical temperature profiles established for the sub-base, could explain the measured infiltration during parts of the winter season. When the release of major and trace elements as function of field pH was compared with pH dependent release data measured in the laboratory, some similar pH trends were found. The field concentrations of Cd, Ni, Pb and Zn were found to be low throughout the monitoring period. During two of the winter seasons, a concentration increase of Cr and Mo was observed, possibly due to the use of de-icing salt. The concentrations of the trace constituents did not exceed Norwegian acceptance criteria for ground water and surface water Class II.
Collapse
|