1
|
Sharma V, Mottafegh A, Joo JU, Kang JH, Wang L, Kim DP. Toward microfluidic continuous-flow and intelligent downstream processing of biopharmaceuticals. LAB ON A CHIP 2024; 24:2861-2882. [PMID: 38751338 DOI: 10.1039/d3lc01097j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2024]
Abstract
Biopharmaceuticals have emerged as powerful therapeutic agents, revolutionizing the treatment landscape for various diseases, including cancer, infectious diseases, autoimmune and genetic disorders. These biotherapeutics pave the way for precision medicine with their unique and targeted capabilities. The production of high-quality biologics entails intricate manufacturing processes, including cell culture, fermentation, purification, and formulation, necessitating specialized facilities and expertise. These complex processes are subject to rigorous regulatory oversight to evaluate the safety, efficacy, and quality of biotherapeutics prior to clinical approval. Consequently, these drugs undergo extensive purification unit operations to achieve high purity by effectively removing impurities and contaminants. The field of personalized precision medicine necessitates the development of novel and highly efficient technologies. Microfluidic technology addresses unmet needs by enabling precise and compact separation, allowing rapid, integrated and continuous purification modules. Moreover, the integration of intelligent biomanufacturing systems with miniaturized devices presents an opportunity to significantly enhance the robustness of complex downstream processing of biopharmaceuticals, with the benefits of automation and advanced control. This allows seamless data exchange, real-time monitoring, and synchronization of purification steps, leading to improved process efficiency, data management, and decision-making. Integrating autonomous systems into biopharmaceutical purification ensures adherence to regulatory standards, such as good manufacturing practice (GMP), positioning the industry to effectively address emerging market demands for personalized precision nano-medicines. This perspective review will emphasize on the significance, challenges, and prospects associated with the adoption of continuous, integrated, and intelligent methodologies in small-scale downstream processing for various types of biologics. By utilizing microfluidic technology and intelligent systems, purification processes can be enhanced for increased efficiency, cost-effectiveness, and regulatory compliance, shaping the future of biopharmaceutical production and enabling the development of personalized and targeted therapies.
Collapse
Affiliation(s)
- Vikas Sharma
- Center for Intelligent Microprocess of Pharmaceutical Synthesis, Department of Chemical Engineering, Pohang University of Science and Technology (POSTECH), Pohang 37673, Republic of Korea.
| | - Amirreza Mottafegh
- Center for Intelligent Microprocess of Pharmaceutical Synthesis, Department of Chemical Engineering, Pohang University of Science and Technology (POSTECH), Pohang 37673, Republic of Korea.
| | - Jeong-Un Joo
- Center for Intelligent Microprocess of Pharmaceutical Synthesis, Department of Chemical Engineering, Pohang University of Science and Technology (POSTECH), Pohang 37673, Republic of Korea.
| | - Ji-Ho Kang
- Center for Intelligent Microprocess of Pharmaceutical Synthesis, Department of Chemical Engineering, Pohang University of Science and Technology (POSTECH), Pohang 37673, Republic of Korea.
| | - Lei Wang
- School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin 150001, Heilongjiang, P. R. China
| | - Dong-Pyo Kim
- Center for Intelligent Microprocess of Pharmaceutical Synthesis, Department of Chemical Engineering, Pohang University of Science and Technology (POSTECH), Pohang 37673, Republic of Korea.
| |
Collapse
|
2
|
Badiye A, Kapoor N, Shukla RK. Detection and separation of proteins using micro/nanofluidics devices. PROGRESS IN MOLECULAR BIOLOGY AND TRANSLATIONAL SCIENCE 2022; 186:59-84. [PMID: 35033290 DOI: 10.1016/bs.pmbts.2021.07.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Microfluidics is the technology or system wherein the behavior of fluids' is studied onto a miniaturized device composed of chambers and tunnels. In biological and biomedical sciences, microfluidic technology/system or device serves as an ultra-high-output approach capable of detecting and separating the biomolecules present even in trace quantities. Given the essential role of protein, the identification and quantification of proteins help understand the various living systems' biological function regulation. Microfluidics has enormous potential to enable biological investigation at the cellular and molecular level and maybe a fair substitution of the sophisticated instruments/equipment used for proteomics, genomics, and metabolomics analysis. The current advancement in microfluidic systems' development is achieving momentum and opening new avenues in developing innovative and hybrid methodologies/technologies. This chapter attempts to expound the micro/nanofluidic systems/devices for their wide-ranging application to detect and separate protein. It covers microfluidic chip electrophoresis, microchip gel electrophoresis, and nanofluidic systems as protein separation systems, while methods such as spectrophotometric, mass spectrometry, electrochemical detection, magneto-resistive sensors and dynamic light scattering (DLS) are discussed as proteins' detection system.
Collapse
Affiliation(s)
- Ashish Badiye
- Department of Forensic Science, Government Institute of Forensic Sciences, Nagpur, Maharashtra, India
| | - Neeti Kapoor
- Department of Forensic Science, Government Institute of Forensic Sciences, Nagpur, Maharashtra, India
| | - Ritesh K Shukla
- Biological and Life Sciences, School of Arts and Sciences, Ahmedabad University, Ahmedabad, Gujarat, India.
| |
Collapse
|
3
|
Rodríguez-Ruiz I, Babenko V, Martínez-Rodríguez S, Gavira JA. Protein separation under a microfluidic regime. Analyst 2017; 143:606-619. [PMID: 29214270 DOI: 10.1039/c7an01568b] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Lab-on-a-Chip (LoC), or micro-Total Analysis Systems (μTAS), is recognized as a powerful analytical technology with high capabilities, though end-user products for protein purification are still far from being available on the market. Remarkable progress has been achieved in the separation of nucleic acids and proteins using electrophoretic microfluidic devices, while pintsize devices have been developed for protein isolation according to miniaturized chromatography principles (size, charge, affinity, etc.). In this work, we review the latest advances in the fabrication of components, detection methods and commercial implementation for the separation of biological macromolecules based on microfluidic systems, with some critical remarks on the perspectives of their future development towards standardized microfluidic systems and protocols. An outlook on the current needs and future applications is also presented.
Collapse
Affiliation(s)
| | - V Babenko
- Laboratorio de Estudios Cristalograficos, Instituto Andaluz de Ciencias de la Tierra, CSIC-University of Granada, Avenida de las Palmeras 4, 18100 Armilla, Granada, Spain.
| | - S Martínez-Rodríguez
- Department of Biochemistry and Molecular Biology III and Immunology. University of Granada, Granada, Spain
| | - J A Gavira
- Laboratorio de Estudios Cristalograficos, Instituto Andaluz de Ciencias de la Tierra, CSIC-University of Granada, Avenida de las Palmeras 4, 18100 Armilla, Granada, Spain.
| |
Collapse
|
4
|
Cong H, Xu X, Yu B, Liu H, Yuan H. Fabrication of anti-protein-fouling poly(ethylene glycol) microfluidic chip electrophoresis by sandwich photolithography. BIOMICROFLUIDICS 2016; 10:044106. [PMID: 27493702 PMCID: PMC4958108 DOI: 10.1063/1.4959239] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/26/2016] [Accepted: 07/11/2016] [Indexed: 06/06/2023]
Abstract
Microfluidic chip electrophoresis (MCE) is a powerful separation tool for biomacromolecule analysis. However, adsorption of biomacromolecules, particularly proteins onto microfluidic channels severely degrades the separation performance of MCE. In this paper, an anti-protein-fouling MCE was fabricated using a novel sandwich photolithography of poly(ethylene glycol) (PEG) prepolymers. Photopatterned microchannel with a minimum resolution of 10 μm was achieved. After equipped with a conventional online electrochemical detector, the device enabled baseline separation of bovine serum albumin, lysozyme (Lys), and cytochrome c (Cyt-c) in 53 s under a voltage of 200 V. Compared with a traditional polydimethylsiloxane MCE made by soft lithography, the PEG MCE made by the sandwich photolithography not only eliminated the need of a master mold and the additional modification process of the microchannel but also showed excellent anti-protein-fouling properties for protein separation.
Collapse
Affiliation(s)
| | - Xiaodan Xu
- College of Materials Science and Engineering, Qingdao University , Qingdao 266071, China
| | | | - Huwei Liu
- Beijing National Laboratory for Molecular Sciences (BNLMS), College of Chemistry and Molecular Engineering, Peking University , Beijing 100871, China
| | - Hua Yuan
- College of Materials Science and Engineering, Qingdao University , Qingdao 266071, China
| |
Collapse
|
5
|
Chen Y, Deng N, Wu C, Liang Y, Jiang B, Yang K, Liang Z, Zhang L, Zhang Y. Aptamer functionalized hydrophilic polymer monolith with gold nanoparticles modification for the sensitive detection of human α-thrombin. Talanta 2016; 154:555-9. [DOI: 10.1016/j.talanta.2016.02.054] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2015] [Revised: 02/18/2016] [Accepted: 02/23/2016] [Indexed: 12/15/2022]
|
6
|
Knob R, Sahore V, Sonker M, Woolley AT. Advances in monoliths and related porous materials for microfluidics. BIOMICROFLUIDICS 2016; 10:032901. [PMID: 27190564 PMCID: PMC4859832 DOI: 10.1063/1.4948507] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2016] [Accepted: 04/20/2016] [Indexed: 05/06/2023]
Abstract
In recent years, the use of monolithic porous polymers has seen significant growth. These materials present a highly useful support for various analytical and biochemical applications. Since their introduction, various approaches have been introduced to produce monoliths in a broad range of materials. Simple preparation has enabled their easy implementation in microchannels, extending the range of applications where microfluidics can be successfully utilized. This review summarizes progress regarding monoliths and related porous materials in the field of microfluidics between 2010 and 2015. Recent developments in monolith preparation, solid-phase extraction, separations, and catalysis are critically discussed. Finally, a brief overview of the use of these porous materials for analysis of subcellular and larger structures is given.
Collapse
Affiliation(s)
- Radim Knob
- Department of Chemistry and Biochemistry, Brigham Young University , Provo, Utah 84602, USA
| | - Vishal Sahore
- Department of Chemistry and Biochemistry, Brigham Young University , Provo, Utah 84602, USA
| | - Mukul Sonker
- Department of Chemistry and Biochemistry, Brigham Young University , Provo, Utah 84602, USA
| | - Adam T Woolley
- Department of Chemistry and Biochemistry, Brigham Young University , Provo, Utah 84602, USA
| |
Collapse
|
7
|
Acquah C, Moy CKS, Danquah MK, Ongkudon CM. Development and characteristics of polymer monoliths for advanced LC bioscreening applications: A review. J Chromatogr B Analyt Technol Biomed Life Sci 2016; 1015-1016:121-134. [PMID: 26919447 DOI: 10.1016/j.jchromb.2016.02.016] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2015] [Revised: 02/13/2016] [Accepted: 02/13/2016] [Indexed: 01/05/2023]
Abstract
Biomedical research advances over the past two decades in bioseparation science and engineering have led to the development of new adsorbent systems called monoliths, mostly as stationary supports for liquid chromatography (LC) applications. They are acknowledged to offer better mass transfer hydrodynamics than their particulate counterparts. Also, their architectural and morphological traits can be tailored in situ to meet the hydrodynamic size of molecules which include proteins, pDNA, cells and viral targets. This has enabled their development for a plethora of enhanced bioscreening applications including biosensing, biomolecular purification, concentration and separation, achieved through the introduction of specific functional moieties or ligands (such as triethylamine, N,N-dimethyl-N-dodecylamine, antibodies, enzymes and aptamers) into the molecular architecture of monoliths. Notwithstanding, the application of monoliths presents major material and bioprocess challenges. The relationship between in-process polymerisation characteristics and the physicochemical properties of monolith is critical to optimise chromatographic performance. There is also a need to develop theoretical models for non-invasive analyses and predictions. This review article therefore discusses in-process analytical conditions, functionalisation chemistries and ligands relevant to establish the characteristics of monoliths in order to facilitate a wide range of enhanced bioscreening applications. It gives emphasis to the development of functional polymethacrylate monoliths for microfluidic and preparative scale bio-applications.
Collapse
Affiliation(s)
- Caleb Acquah
- Curtin Sarawak Research Institute, Curtin University, Sarawak 98009, Malaysia; Department of Chemical Engineering, Curtin University, Sarawak 98009, Malaysia
| | - Charles K S Moy
- Department of Civil Engineering, Xi'an Jiaotong-Liverpool University, Jiangsu 215123, China
| | - Michael K Danquah
- Curtin Sarawak Research Institute, Curtin University, Sarawak 98009, Malaysia; Department of Chemical Engineering, Curtin University, Sarawak 98009, Malaysia.
| | - Clarence M Ongkudon
- Biotechnology Research Institute, Universiti Malaysia Sabah, Kota Kinabalu, Sabah 88400, Malaysia
| |
Collapse
|
8
|
A review on recent developments for biomolecule separation at analytical scale using microfluidic devices. Anal Chim Acta 2016; 906:7-21. [DOI: 10.1016/j.aca.2015.11.037] [Citation(s) in RCA: 70] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2015] [Revised: 11/24/2015] [Accepted: 11/25/2015] [Indexed: 02/05/2023]
|
9
|
Acquah C, Danquah MK, Agyei D, Moy CKS, Sidhu A, Ongkudon CM. Deploying aptameric sensing technology for rapid pandemic monitoring. Crit Rev Biotechnol 2015; 36:1010-1022. [PMID: 26381238 DOI: 10.3109/07388551.2015.1083940] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
The genome of virulent strains may possess the ability to mutate by means of antigenic shift and/or antigenic drift as well as being resistant to antibiotics with time. The outbreak and spread of these virulent diseases including avian influenza (H1N1), severe acute respiratory syndrome (SARS-Corona virus), cholera (Vibrio cholera), tuberculosis (Mycobacterium tuberculosis), Ebola hemorrhagic fever (Ebola Virus) and AIDS (HIV-1) necessitate urgent attention to develop diagnostic protocols and assays for rapid detection and screening. Rapid and accurate detection of first cases with certainty will contribute significantly in preventing disease transmission and escalation to pandemic levels. As a result, there is a need to develop technologies that can meet the heavy demand of an all-embedded, inexpensive, specific and fast biosensing for the detection and screening of pathogens in active or latent forms to offer quick diagnosis and early treatments in order to avoid disease aggravation and unnecessary late treatment costs. Nucleic acid aptamers are short, single-stranded RNA or DNA sequences that can selectively bind to specific cellular and biomolecular targets. Aptamers, as new-age bioaffinity probes, have the necessary biophysical characteristics for improved pathogen detection. This article seeks to review global pandemic situations in relation to advances in pathogen detection systems. It particularly discusses aptameric biosensing and establishes application opportunities for effective pandemic monitoring. Insights into the application of continuous polymeric supports as the synthetic base for aptamer coupling to provide the needed convective mass transport for rapid screening is also presented.
Collapse
Affiliation(s)
- Caleb Acquah
- a Curtin Sarawak Research Institute, Curtin University , Sarawak 98009 , Malaysia.,b Department of Chemical Engineering , Curtin University , Sarawak 98009 , Malaysia
| | - Michael K Danquah
- b Department of Chemical Engineering , Curtin University , Sarawak 98009 , Malaysia
| | - Dominic Agyei
- c Centre for Chemistry and Biotechnology, School of Life and Environmental Sciences Deakin University , Geelong-Waurn Ponds , Australia
| | - Charles K S Moy
- d Faculty of Engineering and Science , Curtin University , Sarawak 98009 , Malaysia
| | - Amandeep Sidhu
- a Curtin Sarawak Research Institute, Curtin University , Sarawak 98009 , Malaysia.,e Faculty of Health Sciences , Curtin University , Perth 6102 , Australia , and
| | - Clarence M Ongkudon
- f Biotechnology Research Institute, Universiti Malaysia Sabah, Kota Kinabalu , Sabah, 88400 , Malaysia
| |
Collapse
|
10
|
Microfluidic chip-based silver nanoparticles aptasensor for colorimetric detection of thrombin. Talanta 2015; 150:81-7. [PMID: 26838384 DOI: 10.1016/j.talanta.2015.09.013] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2015] [Revised: 09/03/2015] [Accepted: 09/06/2015] [Indexed: 12/21/2022]
Abstract
In this paper, a colorimetric silver nanoparticles aptasensor (aptamer-AgNPs) was developed for simple and straightforward detection of protein in microfluidic chip. Surface-functionalized microfluidic channels were employed as the capture platform. Then the mixture of target protein and aptamer-AgNPs were injected into the microfluidic channels for colorimetric detection. To demonstrate the performance of this detection platform, thrombin was chosen as a model target protein. Introduction of thrombin could form a sandwich-type complex involving immobilized AgNPs. The amount of aptamer-AgNPs on the complex augmented along with the increase of the thrombin concentration causing different color change that can be analyzed both by naked eyes and a flatbed scanner. This method is featured with low sample consumption, simple processes of microfluidic platform and straightforward colorimetric detection with aptamer-AgNPs. Thrombin at concentrations as low as 20pM can be detected using this aptasensor without signal amplification. This work demonstrated that it had good selectivity over other proteins and it could be a useful strategy to detect other targets with two affinity binding sites for ligands as well.
Collapse
|
11
|
Galievsky VA, Stasheuski AS, Krylov SN. Capillary Electrophoresis for Quantitative Studies of Biomolecular Interactions. Anal Chem 2014; 87:157-71. [DOI: 10.1021/ac504219r] [Citation(s) in RCA: 82] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Victor A. Galievsky
- Department
of Chemistry and
Centre for Research on Biomolecular Interactions, York University, Toronto, Ontario M3J 1P3, Canada
| | - Alexander S. Stasheuski
- Department
of Chemistry and
Centre for Research on Biomolecular Interactions, York University, Toronto, Ontario M3J 1P3, Canada
| | - Sergey N. Krylov
- Department
of Chemistry and
Centre for Research on Biomolecular Interactions, York University, Toronto, Ontario M3J 1P3, Canada
| |
Collapse
|
12
|
Brothier F, Pichon V. Miniaturized DNA aptamer-based monolithic sorbent for selective extraction of a target analyte coupled on-line to nanoLC. Anal Bioanal Chem 2014; 406:7875-86. [PMID: 25335821 DOI: 10.1007/s00216-014-8256-z] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2014] [Revised: 10/01/2014] [Accepted: 10/08/2014] [Indexed: 10/24/2022]
Abstract
A complete characterization of a novel target-specific DNA aptamer-based miniaturized solid phase extraction (SPE)-sorbent coupled on-line to nanoLC is presented. A miniaturized oligosorbent (mOS) was prepared via the in situ sol-gel synthesis of a hybrid organic-inorganic monolith in 100 μm i.d. capillary columns using tetraethoxysilane and 3-aminopropyltriethoxysilane as precursors, followed by covalent binding of a 5'-amino-modified DNA aptamer with a C12 spacer arm specific for a molecule of small molecular weight. Ochratoxin A (OTA), one of the most abundant naturally occurring mycotoxins, was chosen as model analyte to demonstrate the principle of such an approach. The mOS was coupled on-line to RP-nanoLC-LIF. Selective extraction of OTA on several mOSs was demonstrated with an average extraction recovery above 80 % when percolating spiked binding buffer and a low recovery on control monoliths grafted with a non-specific aptamer. Reproducibility of mOSs preparation was highlighted by comparing extraction yields. Otherwise, the mOSs demonstrated no cross-reactivity towards an OTA structural analogue, i.e., ochratoxin B. Due to the high specific surface area of the hybrid silica-based monolith, the coverage density of DNA aptamers covalently immobilized in the capillaries was very high and reached 6.27 nmol μL(-1), thus leading to a capacity above 5 ng of OTA. This miniaturized device was then applied to the selective extraction of OTA from beer samples. It revealed to be effective in isolating OTA from this complex matrix, thus improving the reliability of its analysis at the trace level.
Collapse
Affiliation(s)
- Fabien Brothier
- Department of Analytical, Bioanalytical Sciences and Miniaturization (LSABM)-UMR CBI 8231 (CNRS-ESPCI), ESPCI ParisTech, PSL Research University, 10 rue Vauquelin, 75231, Paris Cedex 05, France
| | | |
Collapse
|
13
|
Aptamer-based-sorbents for sample treatment--a review. Anal Bioanal Chem 2014; 407:681-98. [PMID: 25286873 DOI: 10.1007/s00216-014-8129-5] [Citation(s) in RCA: 61] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2014] [Revised: 08/20/2014] [Accepted: 08/21/2014] [Indexed: 10/24/2022]
Abstract
To improve selectivity during sample pretreatment, various selective tools inducing a molecular recognition mechanism during the extraction procedure have been developed, such as sorbents constituted of immobilized antibodies, i.e., immunosorbents, or molecularly imprinted polymers. More recently, as an alternative to both previous approaches, aptamers immobilized onto a solid support, i.e., oligosorbents, were proposed. Thanks to the high affinity and high selectivity of the interaction that some aptamers offer toward some target analytes, they also provide powerful techniques that make selective extraction and the concentration of a target analyte from liquid matrices in one step or sample purification of extracts from solid matrices possible. This review describes the development and the properties of these oligosorbents developed for different types of targets-pharmaceuticals, mycotoxins, proteins, cells, etc. After describing the immobilization procedures, we discuss different parameters characterizing the potential of aptamer-based supports as extraction sorbents. Close relations exist between extraction recoveries and the affinity and amounts of aptamers immobilized on the extraction device. In addition, analyte-aptamer interactions may be affected by matrix components and by additives in the samples. This may also lower extraction recoveries and affect the stability and the possible reusability of the aptamer-based sorbent. All these points are discussed and illustrated. Numerous examples of applications of these sorbents to the treatment of complex samples such as food samples, environmental samples, and biological fluids are also reported. Their association with analytical devices, from conventional to miniaturized analytical systems, is also discussed.
Collapse
|
14
|
Chung M, Kim D, Herr AE. Polymer sieving matrices in microanalytical electrophoresis. Analyst 2014; 139:5635-54. [DOI: 10.1039/c4an01179a] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|