1
|
Xin Y, Foster SW, Makey DM, Parker D, Bradow J, Wang X, Berritt S, Mongillo R, Grinias JP, Kennedy RT. High-Throughput Capillary Liquid Chromatography Using a Droplet Injection and Application to Reaction Screening. Anal Chem 2024; 96:4693-4701. [PMID: 38442211 PMCID: PMC11001260 DOI: 10.1021/acs.analchem.4c00150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/07/2024]
Abstract
The cycle time of a standard liquid chromatography (LC) system is the sum of the time for the chromatographic run and the autosampler injection sequence. Although LC separation times in the 1-10 s range have been demonstrated, injection sequences are commonly >15 s, limiting throughput possible with LC separations. Further, such separations are performed on relatively large bore columns requiring flow rates of ≥5 mL/min, thus generating large volumes of mobile phase waste when used for large scale screening and increasing the difficulty in interfacing to mass spectrometry. Here, a droplet injector system was established that replaces the autosampler with a four-port, two-position valve equipped with a 20 nL internal loop interfaced to a syringe pump and a three-axis positioner to withdraw sample droplets from a well plate. In the system, sample and immiscible fluid are pulled alternately from a well plate into a capillary and then through the injection valve. The valve is actuated when sample fills the loop to allow sequential injection of samples at high throughput. Capillary LC columns with 300 μm inner diameter were used to reduce the consumption of mobile phase and sample. The system achieved 96 separations of 20 nL droplet samples containing 3 components in as little as 8.1 min with 5-s cycle time. This system was coupled to a mass spectrometer through an electrospray ionization source for high-throughput chemical reaction screening.
Collapse
Affiliation(s)
- Yue Xin
- Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Samuel W Foster
- Department of Chemistry and Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| | - Devin M Makey
- Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Deklin Parker
- Department of Chemistry and Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| | - James Bradow
- Pfizer Global Research and Development, Eastern Point Road, Groton, Connecticut 06415, United States
| | - Xiaochun Wang
- Pfizer Global Research and Development, Eastern Point Road, Groton, Connecticut 06415, United States
| | - Simon Berritt
- Pfizer Global Research and Development, Eastern Point Road, Groton, Connecticut 06415, United States
| | - Robert Mongillo
- Pfizer Global Research and Development, Eastern Point Road, Groton, Connecticut 06415, United States
| | - James P Grinias
- Department of Chemistry and Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| | - Robert T Kennedy
- Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States
- Department of Pharmacology, University of Michigan, Ann Arbor, Michigan 48109, United States
| |
Collapse
|
2
|
Moussa A, Deridder S, Broeckhoven K, Desmet G. Computational Fluid Dynamics Study of the Dispersion Caused by Capillary Misconnection in Nano-Flow Liquid Chromatography. Anal Chem 2023; 95:13975-13983. [PMID: 37671479 DOI: 10.1021/acs.analchem.3c02550] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/07/2023]
Abstract
It is well known that high-speed/high-efficiency separations in nano-flow liquid chromatography (LC) are very sensitive to the quality of the connections between the column and the rest of the instrument. In the present study, two types of connection errors (capillary misalignment and the occurrence of an inter-capillary gap) have been investigated using computational fluid dynamics. Interestingly, it has been found that large degrees of capillary misalignment (assuming an otherwise perfect contact between the capillary end-faces) can be afforded without introducing any significant dispersion over the entire range of investigated relative misalignment errors (0 ≤ ε/dcap ≤ 75%), even at the largest flow rates considered in nano-LC. On the other hand, when an inter-capillary gap is present, the dispersion very rapidly increases with the radial width Dc of this gap (extra variance ∼Dcn with n even reaching values above 4). The dependency on the gap length Lc is however much smaller. Results show that, when Dc ≤ 30 μm and Lc ≤ 200 μm, dispersion losses can be limited to the order of 1 nL2 at a flow of 1.5 μL/min, which is generally very small compared to the dispersion in the capillaries (20 μm i.d.) themselves. This result also reconfirms that zero-dead volume connectors with a sufficiently narrow bore can in theory be used without compromising peak dispersion in nano-LC, at least when the capillaries can be matched perfectly to the connector in- and outlet faces. The results are also indicative of the extra dispersion occurring inside microfluidic chips or in the connections between a microfluidic chip and the outer world.
Collapse
Affiliation(s)
- Ali Moussa
- Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussels, Belgium
| | - Sander Deridder
- Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussels, Belgium
| | - Ken Broeckhoven
- Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussels, Belgium
| | - Gert Desmet
- Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussels, Belgium
| |
Collapse
|
3
|
Fekete S, Guillarme D. Ultra-short columns for the chromatographic analysis of large molecules. J Chromatogr A 2023; 1706:464285. [PMID: 37562104 DOI: 10.1016/j.chroma.2023.464285] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2023] [Revised: 07/31/2023] [Accepted: 08/04/2023] [Indexed: 08/12/2023]
Abstract
Today, reverse phase liquid chromatography (RPLC) analysis of proteins is almost exclusively performed on conventional columns (100-150 mm) in gradient elution mode. However, it was shown many years ago that large molecules present an on/off retention mechanism, and that only a very short inlet segment of the chromatographic column retains effectively the large molecules. Much shorter columns - like only a few centimetres or even a few millimetres - can therefore be used to efficiently analyse such macromolecules. The aim of this review is to summarise the historical and more recent works related to the use of very short columns for the analysis of model and therapeutic proteins. To this end, we have outlined the theoretical concepts behind the use of short columns, as well as the instrumental limitations and potential applications. Finally, we have shown that these very short columns were also possibly interesting for other chromatographic modes, such as ion exchange chromatography (IEX), hydrophilic interaction chromatography (HILIC) or hydrophobic interaction chromatography (HIC), as analyses in these chromatographic modes are performed in gradient elution mode.
Collapse
Affiliation(s)
| | - Davy Guillarme
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland; School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland.
| |
Collapse
|
4
|
Moussa A, Broeckhoven K, Desmet G. Fundamental investigation of the dispersion caused by a change in diameter in nano liquid chromatography capillary tubing. J Chromatogr A 2023; 1688:463719. [PMID: 36542892 DOI: 10.1016/j.chroma.2022.463719] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Revised: 12/09/2022] [Accepted: 12/13/2022] [Indexed: 12/23/2022]
Abstract
We report on a Computational Fluid Dynamics (CFD) study of the extra dispersion caused by the change in diameter when coupling two pieces of capillary tubing with different diameter. In this first investigation into the problem, the focus is on the typical flow rates (0.25≤F≤2μL/min) and diameters (d≤40μm) used in nano-LC, considering both the case of either a doubling or halving of the diameter. The CFD simulations allow to study the problem from a fundamental point of view, i.e., under otherwise perfect conditions (perfect alignment, zero dead-volume). Flow rates, capillary diameters, diffusion coefficients and liquid viscosities have been varied over a range relevant for nano-LC (Reynolds-numbers Re ≤ 1), with also an excursion made towards high-temperature nano-LC conditions (Re ≥ 10 and more). The extra dispersion caused by the change in diameter has been quantified via a volumetric variance σ2conn, defined in such a way that the overall dispersion across the entire capillary system can be easily reconstructed from the known analytical solutions in the individual segments. When the two capillaries are longer than their diffusion entry length, covering most of the practical cases, σ2conn converges to a limiting value σ2conn,∞ which varies to a close approximation with the square of flow rate. Under the investigated nano-LC conditions, the σ2conn,∞-values are surprisingly small (e.g., on the order of 0.01 to 0.15 nL2 in a 20 to 40μm connection) compared to the dispersion occurring in the remainder of the capillaries.
Collapse
Affiliation(s)
- Ali Moussa
- Vrije Universiteit Brussel, Pleinlaan 2, Brussels 1050, Belgium
| | - Ken Broeckhoven
- Vrije Universiteit Brussel, Pleinlaan 2, Brussels 1050, Belgium
| | - Gert Desmet
- Vrije Universiteit Brussel, Pleinlaan 2, Brussels 1050, Belgium.
| |
Collapse
|
5
|
Lenčo J, Jadeja S, Naplekov DK, Krokhin OV, Khalikova MA, Chocholouš P, Urban J, Broeckhoven K, Nováková L, Švec F. Reversed-Phase Liquid Chromatography of Peptides for Bottom-Up Proteomics: A Tutorial. J Proteome Res 2022; 21:2846-2892. [PMID: 36355445 DOI: 10.1021/acs.jproteome.2c00407] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The performance of the current bottom-up liquid chromatography hyphenated with mass spectrometry (LC-MS) analyses has undoubtedly been fueled by spectacular progress in mass spectrometry. It is thus not surprising that the MS instrument attracts the most attention during LC-MS method development, whereas optimizing conditions for peptide separation using reversed-phase liquid chromatography (RPLC) remains somewhat in its shadow. Consequently, the wisdom of the fundaments of chromatography is slowly vanishing from some laboratories. However, the full potential of advanced MS instruments cannot be achieved without highly efficient RPLC. This is impossible to attain without understanding fundamental processes in the chromatographic system and the properties of peptides important for their chromatographic behavior. We wrote this tutorial intending to give practitioners an overview of critical aspects of peptide separation using RPLC to facilitate setting the LC parameters so that they can leverage the full capabilities of their MS instruments. After briefly introducing the gradient separation of peptides, we discuss their properties that affect the quality of LC-MS chromatograms the most. Next, we address the in-column and extra-column broadening. The last section is devoted to key parameters of LC-MS methods. We also extracted trends in practice from recent bottom-up proteomics studies and correlated them with the current knowledge on peptide RPLC separation.
Collapse
Affiliation(s)
- Juraj Lenčo
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05Hradec Králové, Czech Republic
| | - Siddharth Jadeja
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05Hradec Králové, Czech Republic
| | - Denis K Naplekov
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05Hradec Králové, Czech Republic
| | - Oleg V Krokhin
- Department of Internal Medicine, Manitoba Centre for Proteomics and Systems Biology, University of Manitoba, 799 JBRC, 715 McDermot Avenue, WinnipegR3E 3P4, Manitoba, Canada
| | - Maria A Khalikova
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05Hradec Králové, Czech Republic
| | - Petr Chocholouš
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05Hradec Králové, Czech Republic
| | - Jiří Urban
- Department of Chemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00Brno, Czech Republic
| | - Ken Broeckhoven
- Department of Chemical Engineering (CHIS), Faculty of Engineering, Vrije Universiteit Brussel, Pleinlaan 2, 1050Brussel, Belgium
| | - Lucie Nováková
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05Hradec Králové, Czech Republic
| | - František Švec
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05Hradec Králové, Czech Republic
| |
Collapse
|
6
|
Gritti FG, Meyyappan S, Leveille WP, Hill J. Improved Performance of UHPLC–MS Hyphenated Systems. LCGC NORTH AMERICA 2022. [DOI: 10.56530/lcgc.na.im3069q9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
Abstract
An ultrahigh-pressure liquid chromatography–mass spectrometry (UHPLC–MS) research prototype instrument was built to improve the resolution power and the usability of conventional LC–MS hyphenated instruments for routine analyses in pharmaceutical applications. The improved characteristics of this UHPLC–MS system include: 1) the dramatic reduction of post-column sample dispersion; 2) the adoption of vacuum jacketed columns (VJC) for the reduction of undesirable radial temperature gradients across the column diameter; and 3) the presence of a column outlet end nut heater to refocus the distorted peaks prior to analyte ionization. The benefits of each of these added features are analyzed with a rigorous approach from a peak broadening perspective. A 2x improvement in peak capacities recorded with this prototype UHPLC–MS system compared to a standard system (Acquity UHPLC I-class/Xevo TQ-S) is illustrated for the gradient separation of seven small pharmaceutical compounds using a 2.1 mm x 100 mm column packed with sub-2-μm core-shell particles (1.6 μm Acquity UHPLC Cortecs C18 column).
Collapse
|
7
|
Yang S, Li N, Ma Z, Tang T, Li T. [Research advances in nano liquid chromatography instrumentation]. Se Pu 2021; 39:1065-1076. [PMID: 34505428 PMCID: PMC9404240 DOI: 10.3724/sp.j.1123.2021.06017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
The miniaturization of liquid chromatography equipment is among the most important focus areas in chromatographic technology. It involves the miniaturization of the physical dimensions of the instrument, size of the separation material, and inner diameter of the column. The advantages of a reduced inner diameter of the column have been investigated for several decades, and can be summarized as follows. First, the sample consumption is lower, which is particularly beneficial when a limited amount of sample is available, as is the case with natural products, and in biochemistry and biomedicine. Second, the consumption of the mobile phase is reduced, making the process environmentally friendly and facilitating green chemistry. This allows the addition of more expensive solvent additives, such as chiral additives or isotopic reagents, while maintaining a low analysis cost. Moreover, the degree of band dilution in the column is lower than that with conventional liquid chromatography under the same sample injection conditions. Thus, enhanced mass sensitivity is achieved. Other benefits of a reduced inner diameter of the column include temperature control due to effective heat transfer through the columns and easier coupling to mass detectors, which is particularly advantageous for analyzing complex samples. Typically, the term “nano liquid chromatography” is associated with liquid chromatography, which employs capillary columns of inner diameters less than 100 μm and flow rates in the range of tens to hundreds of nanoliters per minute. Because of the extremely low flow rates and small column volume, the extra-column effect becomes more prominent. Thus, the requirements for every component of liquid chromatographs are augmented toward improving their performance and optimizing the extra-column band broadening of the entire system. The solvent delivery equipment should be able to pump mobile phases accurately and steadily at nanoliter-level flow rates. A gradient mode is required to achieve this, which implies that the lowest flow rate for a single pump unit should reach a few nanoliters per minute. A certain operating pressure is also necessary to employ columns with different inner diameters and particle sizes. A precise and repeatable sample injection procedure is essential for nano liquid chromatography. The injection volume and mode should be suitable for capillary columns, without inducing a significant extra-column effect. A higher-sensitivity detector should be employed, and sample dispersion should be limited. The improved tubing and connection method in nano liquid chromatography should offer stability, reliability, and ease of operation. The extra-column volume should also be restricted to suit nanoliter-level flow rates. Considering that most nano liquid chromatographic instruments have been coupled with a mass detector, this review mainly focused on nanoliter solvent delivery modules, sample injection modules, and tubing and connection modules. By searching and summarizing research articles, technical patents, and brochures of instrument manufacturers, technical routes and research progress on these modules were described in detail. The pump designs can be classified into four types. Pneumatic amplifying pumps have been used in ultra-high-pressure applications. The flow-splitting delivery system, though easy to realize, may lead to a large amount of solvent wastage. Splitless pumps, which are classified based on two main principles, are widely used. Some pumps based on other physical phenomena have been suggested; however, they lacked stability and robustness. Two types of injection modes have been utilized in nano liquid chromatography. The direct nanoliter injection mode typically takes advantage of the groove on the rotor of a switching valve. The trapping injection mode uses trap columns to enable the introduction of large sample volumes. As for the tubing and connection, a few appropriate designs can be acquired from commercial suppliers. The robustness has been improved using some patented technologies. The optimization principles and research progress on optical absorption detection are briefly introduced. Finally, commercial nano liquid chromatographic systems are compared by considering the pumps and injectors.
Collapse
Affiliation(s)
- Sandong Yang
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
| | - Naijie Li
- Dalian Elite Analytical Instruments Co., Ltd., Dalian 116023, China
| | - Zhou Ma
- Dalian Elite Analytical Instruments Co., Ltd., Dalian 116023, China
| | - Tao Tang
- Dalian Elite Analytical Instruments Co., Ltd., Dalian 116023, China
| | - Tong Li
- Dalian Elite Analytical Instruments Co., Ltd., Dalian 116023, China
- Elite Suzhou Analytical Instruments Co., Ltd., Suzhou 215123, China
| |
Collapse
|
8
|
Abstract
Continued improvements in HPLC have led to faster and more efficient separations than previously possible. One important aspect of these improvements has been the increase in instrument operating pressure and the advent of ultrahigh pressure LC (UHPLC). Commercial instrumentation is now capable of up to ~20 kpsi, allowing fast and efficient separations with 5-15 cm columns packed with sub-2 μm particles. Home-built instruments have demonstrated the benefits of even further increases in instrument pressure. The focus of this review is on recent advancements and applications in liquid chromatography above 20 kpsi. We outline the theory and advantages of higher pressure and discuss instrument hardware and design capable of withstanding 20 kpsi or greater. We also overview column packing procedures and stationary phase considerations for HPLC above 20 kpsi, and lastly highlight a few recent applicatioob pressure instruments for the analysis of complex mixtures.
Collapse
Affiliation(s)
- Matthew J Sorensen
- Department of Chemistry, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Brady G Anderson
- Department of Chemistry, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Robert T Kennedy
- Department of Chemistry, University of Michigan, Ann Arbor, MI, 48109, USA.,Department of Pharmacology, University of Michigan, Ann Arbor, MI, 48109, USA
| |
Collapse
|
9
|
Beccaria M, Cabooter D. Current developments in LC-MS for pharmaceutical analysis. Analyst 2020; 145:1129-1157. [DOI: 10.1039/c9an02145k] [Citation(s) in RCA: 55] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Liquid chromatography (LC) based techniques in combination with mass spectrometry (MS) detection have had a large impact on the development of new pharmaceuticals in the past decades.
Collapse
Affiliation(s)
- Marco Beccaria
- KU Leuven
- Department for Pharmaceutical and Pharmacological Sciences
- Pharmaceutical Analysis
- Leuven
- Belgium
| | - Deirdre Cabooter
- KU Leuven
- Department for Pharmaceutical and Pharmacological Sciences
- Pharmaceutical Analysis
- Leuven
- Belgium
| |
Collapse
|
10
|
Optimization of microflow LC-MS/MS and its utility in quantitative discovery bioanalysis. Bioanalysis 2019; 11:1117-1127. [PMID: 31251100 DOI: 10.4155/bio-2019-0076] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Aim: The sensitivity advantage of microflow LC (μFLC)-MS/MS is potentially impactful for challenging compounds not detectable by conventional flow LC-MS/MS in drug discovery bioanalysis. Relatively new to μFLC technology, discovery bioanalytical scientists would benefit from an effective strategy for method development and optimization. Results: A systematic μFLC-MS/MS method optimization approach was developed in this study. With optimized conditions, μFLC-MS/MS demonstrated an improved sensitivity compared with conventional LC-MS/MS analysis, ranging from 6× to 49× (by peak area) depending on the compounds, with acceptable analytical performance and robustness. The optimized conditions demonstrated universal applicability to various compounds of diverse properties. Conclusion: The systematic method optimization strategy, and the general applicability of the optimized conditions could facilitate the routine utilization of μFLC in quantitative discovery bioanalysis.
Collapse
|
11
|
Nys G, Cobraiville G, Fillet M. Multidimensional performance assessment of micro pillar array column chromatography combined to ion mobility-mass spectrometry for proteome research. Anal Chim Acta 2019; 1086:1-13. [DOI: 10.1016/j.aca.2019.08.068] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2019] [Revised: 08/23/2019] [Accepted: 08/27/2019] [Indexed: 01/23/2023]
|
12
|
Broeckhoven K, Desmet G. Advances and Challenges in Extremely High-Pressure Liquid Chromatography in Current and Future Analytical Scale Column Formats. Anal Chem 2019; 92:554-560. [DOI: 10.1021/acs.analchem.9b04278] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Ken Broeckhoven
- Vrije Universiteit Brussel, Department of Chemical Engineering (CHIS), Faculty of Engineering, Pleinlaan 2, 1050 Brussels, Belgium
| | - Gert Desmet
- Vrije Universiteit Brussel, Department of Chemical Engineering (CHIS), Faculty of Engineering, Pleinlaan 2, 1050 Brussels, Belgium
| |
Collapse
|
13
|
Desmet G, Broeckhoven K. Extra-column band broadening effects in contemporary liquid chromatography: Causes and solutions. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.115619] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
14
|
Gritti F, Tanaka N. Slow injector-to-column sample transport to maximize resolution in liquid chromatography: Theory versus practice. J Chromatogr A 2019; 1600:219-237. [DOI: 10.1016/j.chroma.2019.04.060] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2019] [Revised: 04/15/2019] [Accepted: 04/22/2019] [Indexed: 01/08/2023]
|
15
|
Evaluation of meter-long monolithic columns for selected reaction monitoring mass spectrometry. J Biosci Bioeng 2019; 128:379-383. [PMID: 30956101 DOI: 10.1016/j.jbiosc.2019.03.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2018] [Revised: 02/27/2019] [Accepted: 03/08/2019] [Indexed: 02/06/2023]
Abstract
Proteome is extremely complex as many proteins with a large dynamic range are involved. Nano-liquid chromatography/mass spectrometry-based proteomics has made it possible to separate and identify thousands of proteins in one shot. Although the number of identified proteins in proteomics has significantly improved, it is necessary to increase detection sensitivity to clearly identify low-abundant proteins. In this study, we developed meter-long monolithic columns with a small inner diameter and applied them to selected reaction monitoring-based proteomics for improving proteomic detection sensitivity. Bovine serum albumin tryptic digests were analyzed with optimized selected reaction monitoring methods, and separation efficiency and detection sensitivity in each monolithic column were evaluated. As a result, peak capacity increased by about 1.8-fold and peak area of peptide levels increased by about 2.3-fold. Although flow rate was reduced during analysis with columns of a smaller inner diameter, the peak area reproducibility was maintained. These data displayed the value of meter-long monolithic columns with small inner diameter for selected reaction monitoring-based proteomics.
Collapse
|
16
|
Gritti F, Gilar M. Impact of frit dispersion on gradient performance in high-throughput liquid chromatography. J Chromatogr A 2019; 1591:110-119. [DOI: 10.1016/j.chroma.2019.01.021] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2018] [Revised: 01/05/2019] [Accepted: 01/08/2019] [Indexed: 01/19/2023]
|
17
|
Lenčo J, Vajrychová M, Pimková K, Prokšová M, Benková M, Klimentová J, Tambor V, Soukup O. Conventional-Flow Liquid Chromatography-Mass Spectrometry for Exploratory Bottom-Up Proteomic Analyses. Anal Chem 2018; 90:5381-5389. [PMID: 29582996 DOI: 10.1021/acs.analchem.8b00525] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Due to its sensitivity and productivity, bottom-up proteomics based on liquid chromatography-mass spectrometry (LC-MS) has become the core approach in the field. The de facto standard LC-MS platform for proteomics operates at sub-μL/min flow rates, and nanospray is required for efficiently introducing peptides into a mass spectrometer. Although this is almost a "dogma", this view is being reconsidered in light of developments in highly efficient chromatographic columns, and especially with the introduction of exceptionally sensitive MS instruments. Although conventional-flow LC-MS platforms have recently penetrated targeted proteomics successfully, their possibilities in discovery-oriented proteomics have not yet been thoroughly explored. Our objective was to determine what are the extra costs and what optimization and adjustments to a conventional-flow LC-MS system must be undertaken to identify a comparable number of proteins as can be identified on a nanoLC-MS system. We demonstrate that the amount of a complex tryptic digest needed for comparable proteome coverage can be roughly 5-fold greater, providing the column dimensions are properly chosen, extra-column peak dispersion is minimized, column temperature and flow rate are set to levels appropriate for peptide separation, and the composition of mobile phases is fine-tuned. Indeed, we identified 2 835 proteins from 2 μg of HeLa cells tryptic digest separated during a 60 min gradient at 68 μL/min on a 1.0 mm × 250 mm column held at 55 °C and using an aqua-acetonitrile mobile phases containing 0.1% formic acid, 0.4% acetic acid, and 3% dimethyl sulfoxide. Our results document that conventional-flow LC-MS is an attractive alternative for bottom-up exploratory proteomics.
Collapse
Affiliation(s)
- Juraj Lenčo
- Biomedical Research Center , University Hospital Hradec Králové , Sokolská 581 , 500 05 Hradec Králové , Czech Republic.,Department of Molecular Pathology and Biology, Faculty of Military Health Sciences , University of Defence , Třebešská 1575 , 500 01 Hradec Králové , Czech Republic.,Department of Analytical Chemistry, Faculty of Pharmacy , Charles University in Prague , Heyrovského 1203 , 500 05 Hra-dec Králové , Czech Republic
| | - Marie Vajrychová
- Biomedical Research Center , University Hospital Hradec Králové , Sokolská 581 , 500 05 Hradec Králové , Czech Republic.,Department of Molecular Pathology and Biology, Faculty of Military Health Sciences , University of Defence , Třebešská 1575 , 500 01 Hradec Králové , Czech Republic
| | - Kristýna Pimková
- Biomedical Research Center , University Hospital Hradec Králové , Sokolská 581 , 500 05 Hradec Králové , Czech Republic
| | - Magdaléna Prokšová
- Department of Molecular Pathology and Biology, Faculty of Military Health Sciences , University of Defence , Třebešská 1575 , 500 01 Hradec Králové , Czech Republic
| | - Markéta Benková
- Biomedical Research Center , University Hospital Hradec Králové , Sokolská 581 , 500 05 Hradec Králové , Czech Republic
| | - Jana Klimentová
- Department of Molecular Pathology and Biology, Faculty of Military Health Sciences , University of Defence , Třebešská 1575 , 500 01 Hradec Králové , Czech Republic
| | - Vojtěch Tambor
- Biomedical Research Center , University Hospital Hradec Králové , Sokolská 581 , 500 05 Hradec Králové , Czech Republic
| | - Ondřej Soukup
- Biomedical Research Center , University Hospital Hradec Králové , Sokolská 581 , 500 05 Hradec Králové , Czech Republic
| |
Collapse
|
18
|
Broeckhoven K, Vanderlinden K, Guillarme D, Desmet G. On-tubing fluorescence measurements of the band broadening of contemporary injectors in ultra-high performance liquid chromatography. J Chromatogr A 2018; 1535:44-54. [DOI: 10.1016/j.chroma.2017.12.032] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2017] [Revised: 12/08/2017] [Accepted: 12/12/2017] [Indexed: 10/18/2022]
|
19
|
Gilar M, McDonald TS, Gritti F, Roman GT, Johnson JS, Bunner B, Michienzi JD, Collamati RA, Murphy JP, Satpute DD, Bannon MP, DellaRovere D, Jencks RA, Dourdeville TA, Fadgen KE, Gerhardt GC. Chromatographic performance of microfluidic liquid chromatography devices: Experimental evaluation of straight versus serpentine packed channels. J Chromatogr A 2017; 1533:127-135. [PMID: 29249537 DOI: 10.1016/j.chroma.2017.12.031] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2017] [Revised: 12/06/2017] [Accepted: 12/12/2017] [Indexed: 10/18/2022]
Abstract
We prepared a series of planar titanium microfluidic (μLC) columns, each 100 mm long, with 0.15, 0.3 and 0.5 mm i.d.'s. The microfluidic columns were packed with 1.8 μm C18 sorbent and tested under isocratic and gradient conditions. The efficiency and peak capacity of these devices were monitored using a micro LC instrument with minimal extra column dispersion. Columns with serpentine channels were shown to perform worse than those with straight channels. The loss of efficiency and peak capacity was more prominent for wider i.d. columns, presumably due to on-column band broadening imparted by the so-called "race-track" effect. The loss of chromatographic performance was partially mitigated by tapering the turns (reduction in i.d. through the curved region). While good performance was obtained for 0.15 mm i.d. devices even without turn tapering, the performance of 0.3 mm i.d. columns could be brought on par with capillary LC devices by tapering down to 2/3 of the nominal channel width in the turn regions. The loss of performance was not fully compensated for in 0.5 mm devices even when tapering was employed; 30% loss in efficiency and 10% loss in peak capacity was observed. The experimental data for various devices were compared using the expected theoretical relationship between peak capacity Pc and efficiency N; (Pc-1) = N0.5 × const. While straight μLC columns showed the expected behavior, the devices with serpentine channels did not adhere to the plot. The results suggest that the loss of efficiency due to the turns is more pronounced than the corresponding loss of peak capacity.
Collapse
Affiliation(s)
- Martin Gilar
- Waters Corporation, 34 Maple Street, Milford, MA 01757, USA.
| | | | - Fabrice Gritti
- Waters Corporation, 34 Maple Street, Milford, MA 01757, USA
| | | | - Jay S Johnson
- Waters Corporation, 34 Maple Street, Milford, MA 01757, USA
| | - Bernard Bunner
- Waters Corporation, 34 Maple Street, Milford, MA 01757, USA
| | | | | | - Jim P Murphy
- Waters Corporation, 34 Maple Street, Milford, MA 01757, USA
| | | | | | | | | | | | - Keith E Fadgen
- Waters Corporation, 34 Maple Street, Milford, MA 01757, USA
| | | |
Collapse
|
20
|
Impact of instrument and column parameters on high-throughput liquid chromatography performance. J Chromatogr A 2017; 1523:215-223. [DOI: 10.1016/j.chroma.2017.07.035] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2017] [Revised: 07/07/2017] [Accepted: 07/10/2017] [Indexed: 12/21/2022]
|
21
|
Ahmad IAH, Hrovat F, Soliven A, Clarke A, Boswell P, Tarara T, Blasko A. A 14 Parameter Study of UHPLC’s for Method Development Transfer and Troubleshooting. Chromatographia 2017. [DOI: 10.1007/s10337-017-3337-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
22
|
Zhang X, Kew K, Reisdorph R, Sartain M, Powell R, Armstrong M, Quinn K, Cruickshank-Quinn C, Walmsley S, Bokatzian S, Darland E, Rain M, Imatani K, Reisdorph N. Performance of a High-Pressure Liquid Chromatography-Ion Mobility-Mass Spectrometry System for Metabolic Profiling. Anal Chem 2017; 89:6384-6391. [PMID: 28528542 DOI: 10.1021/acs.analchem.6b04628] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
A commercial liquid chromatography/drift tube ion mobility-mass spectrometer (LC/IM-MS) was evaluated for its utility in global metabolomics analysis. Performance was assessed using 12 targeted metabolite standards where the limit of detection (LOD), linear dynamic range, resolving power, and collision cross section (Ω) are reported for each standard. Data were collected in three different instrument operation modes: flow injection analysis with IM-MS (FIA/IM-MS), LC/MS, and LC/IM-MS. Metabolomics analyses of human plasma and HaCaT cells were used to compare the above three operation modes. LC/MS provides linearity in response, data processing automation, improved limits of detection, and ease of use. Advantages of LC/IM-MS and FIA/IM-MS include the ability to develop mobility-mass trend lines for structurally similar biomolecules, increased peak capacity, reduction of chemical/matrix noise, improvement in signal-to-noise, and separations of isobar/isomer compounds that are not resolved by LC. We further tested the feasibility of incorporating IM-MS into conventional LC/MS metabolomics workflows. In general, the addition of ion mobility dimension has increased the separation of compounds in complex biological matrixes and has the potential to largely improve the throughput of metabolomics analysis.
Collapse
Affiliation(s)
- Xing Zhang
- Skaggs School of Pharmacy and Pharmaceutical Sciences, University of Colorado Denver, Anschutz Medical Campus , Aurora, Colorado 80045, United States
| | - Kimberly Kew
- Department of Chemistry, East Carolina University , Greenville, North Carolina 27858, United States
| | - Richard Reisdorph
- Skaggs School of Pharmacy and Pharmaceutical Sciences, University of Colorado Denver, Anschutz Medical Campus , Aurora, Colorado 80045, United States
| | - Mark Sartain
- Life Sciences Group, Agilent Technologies , Santa Clara, California 95051, United States
| | - Roger Powell
- Skaggs School of Pharmacy and Pharmaceutical Sciences, University of Colorado Denver, Anschutz Medical Campus , Aurora, Colorado 80045, United States
| | - Michael Armstrong
- Skaggs School of Pharmacy and Pharmaceutical Sciences, University of Colorado Denver, Anschutz Medical Campus , Aurora, Colorado 80045, United States
| | - Kevin Quinn
- Skaggs School of Pharmacy and Pharmaceutical Sciences, University of Colorado Denver, Anschutz Medical Campus , Aurora, Colorado 80045, United States
| | - Charmion Cruickshank-Quinn
- Skaggs School of Pharmacy and Pharmaceutical Sciences, University of Colorado Denver, Anschutz Medical Campus , Aurora, Colorado 80045, United States
| | - Scott Walmsley
- Skaggs School of Pharmacy and Pharmaceutical Sciences, University of Colorado Denver, Anschutz Medical Campus , Aurora, Colorado 80045, United States
| | - Samantha Bokatzian
- Skaggs School of Pharmacy and Pharmaceutical Sciences, University of Colorado Denver, Anschutz Medical Campus , Aurora, Colorado 80045, United States
| | - Ed Darland
- Life Sciences Group, Agilent Technologies , Santa Clara, California 95051, United States
| | - Matthew Rain
- Life Sciences Group, Agilent Technologies , Santa Clara, California 95051, United States
| | - Ken Imatani
- Life Sciences Group, Agilent Technologies , Santa Clara, California 95051, United States
| | - Nichole Reisdorph
- Skaggs School of Pharmacy and Pharmaceutical Sciences, University of Colorado Denver, Anschutz Medical Campus , Aurora, Colorado 80045, United States
| |
Collapse
|
23
|
Restriction capillaries as an innovative mixing unit for intermediate mobile phase exchange in multidimensional analysis. J Chromatogr A 2017; 1497:70-80. [PMID: 28372840 DOI: 10.1016/j.chroma.2017.03.036] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2016] [Revised: 02/23/2017] [Accepted: 03/17/2017] [Indexed: 12/11/2022]
Abstract
A novel mixing unit is proposed for the serial coupling of orthogonal columns to analyze polar and non-polar compounds in a single run. The principle relies on the isolation of unretained peaks eluting from a first dimension column in a sample loop, before directing them to a second column for separation. Since the mobile phases employed in highly orthogonal separations are not directly compatible, a mixing unit is required to alter the mobile phase composition before executing the second dimension separation. The mixing unit proposed in this work is based on the use of two restriction capillaries with different flow resistances to dilute the mobile phase eluting from the first dimension with a solvent appropriate for the second dimension separation. The restriction capillaries are implemented in an ultra-high performance liquid chromatography set-up using three high-pressure switching valves and two T-pieces. It is demonstrated that the dilution ratio can be adequately predicted using the law of Hagen-Poiseuille and can be adjusted easily by changing the dimensions of the restriction capillaries. The dilution volume required to obtain acceptable recoveries is investigated and the use of different column diameters in the first and second dimension is proposed to increase the sensitivity of the analysis. Under optimum dilution conditions, recoveries ranging between 82% and 99% are always obtained, while repeatability values are excellent. The proof-of-concept of the different set-ups is demonstrated for the separation of 20 pharmaceuticals with log D-values ranging between -5.75 and 4.22.
Collapse
|
24
|
Hetzel T, Blaesing C, Jaeger M, Teutenberg T, Schmidt TC. Characterization of peak capacity of microbore liquid chromatography columns using gradient kinetic plots. J Chromatogr A 2017; 1485:62-69. [DOI: 10.1016/j.chroma.2017.01.018] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2016] [Revised: 01/03/2017] [Accepted: 01/06/2017] [Indexed: 12/19/2022]
|
25
|
Hetzel T, Loeker D, Teutenberg T, Schmidt TC. Characterization of the efficiency of microbore liquid chromatography columns by van Deemter and kinetic plot analysis. J Sep Sci 2016; 39:3889-3897. [DOI: 10.1002/jssc.201600775] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2016] [Revised: 08/10/2016] [Accepted: 08/12/2016] [Indexed: 11/07/2022]
Affiliation(s)
- Terence Hetzel
- Institut für Energie- und Umwelttechnik e. V; IUTA (Institute of Energy and Environmental Technology); Bliersheimer Straße 58-60 Duisburg Germany
- Instrumental Analytical Chemistry; University of Duisburg-Essen; Universitätsstr. 5 Essen Germany
| | - Denise Loeker
- Institut für Energie- und Umwelttechnik e. V; IUTA (Institute of Energy and Environmental Technology); Bliersheimer Straße 58-60 Duisburg Germany
| | - Thorsten Teutenberg
- Institut für Energie- und Umwelttechnik e. V; IUTA (Institute of Energy and Environmental Technology); Bliersheimer Straße 58-60 Duisburg Germany
| | - Torsten C. Schmidt
- Instrumental Analytical Chemistry; University of Duisburg-Essen; Universitätsstr. 5 Essen Germany
| |
Collapse
|
26
|
Gilar M, McDonald TS, Gritti F. Experimental evaluation of chromatographic performance of capillary and microfluidic columns with linear or curved channels. J Chromatogr A 2016; 1470:76-83. [DOI: 10.1016/j.chroma.2016.10.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2016] [Revised: 09/29/2016] [Accepted: 10/05/2016] [Indexed: 11/16/2022]
|
27
|
Vanderheyden Y, Broeckhoven K, Desmet G. Peak deconvolution to correctly assess the band broadening of chromatographic columns. J Chromatogr A 2016; 1465:126-42. [DOI: 10.1016/j.chroma.2016.08.058] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2016] [Revised: 08/24/2016] [Accepted: 08/25/2016] [Indexed: 01/24/2023]
|
28
|
Gritti F, Gilar M, Jarrell JA. Quasi-adiabatic vacuum-based column housing for very high-pressure liquid chromatography. J Chromatogr A 2016; 1456:226-34. [DOI: 10.1016/j.chroma.2016.06.029] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2016] [Revised: 06/07/2016] [Accepted: 06/08/2016] [Indexed: 11/27/2022]
|
29
|
Intrinsic advantages of packed capillaries over narrow-bore columns in very high-pressure gradient liquid chromatography. J Chromatogr A 2016; 1451:107-119. [DOI: 10.1016/j.chroma.2016.05.035] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2016] [Revised: 04/08/2016] [Accepted: 05/08/2016] [Indexed: 11/22/2022]
|
30
|
Villaverde JJ, Sevilla-Morán B, López-Goti C, Alonso-Prados JL, Sandín-España P. Trends in analysis of pesticide residues to fulfil the European Regulation (EC) No. 1107/2009. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2016.04.017] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
31
|
Vanderlinden K, Broeckhoven K, Vanderheyden Y, Desmet G. Effect of pre- and post-column band broadening on the performance of high-speed chromatography columns under isocratic and gradient conditions. J Chromatogr A 2016; 1442:73-82. [DOI: 10.1016/j.chroma.2016.03.016] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2016] [Revised: 03/07/2016] [Accepted: 03/07/2016] [Indexed: 11/25/2022]
|
32
|
Vanderheyden Y, Vanderlinden K, Broeckhoven K, Desmet G. Problems involving the determination of the column-only band broadening in columns producing narrow and tailed peaks. J Chromatogr A 2016; 1440:74-84. [DOI: 10.1016/j.chroma.2016.02.042] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2015] [Revised: 02/12/2016] [Accepted: 02/15/2016] [Indexed: 10/22/2022]
|
33
|
Van Schoors J, Maes K, Van Wanseele Y, Broeckhoven K, Van Eeckhaut A. Miniaturized ultra-high performance liquid chromatography coupled to electrochemical detection: Investigation of system performance for neurochemical analysis. J Chromatogr A 2016; 1427:69-78. [DOI: 10.1016/j.chroma.2015.11.076] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2015] [Revised: 11/19/2015] [Accepted: 11/24/2015] [Indexed: 01/03/2023]
|
34
|
De Vos J, Broeckhoven K, Eeltink S. Advances in Ultrahigh-Pressure Liquid Chromatography Technology and System Design. Anal Chem 2015; 88:262-78. [DOI: 10.1021/acs.analchem.5b04381] [Citation(s) in RCA: 76] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Affiliation(s)
- Jelle De Vos
- Vrije Universiteit Brussel, Department
of Chemical Engineering, Pleinlaan 2, B-1050, Brussels, Belgium
| | - Ken Broeckhoven
- Vrije Universiteit Brussel, Department
of Chemical Engineering, Pleinlaan 2, B-1050, Brussels, Belgium
| | - Sebastiaan Eeltink
- Vrije Universiteit Brussel, Department
of Chemical Engineering, Pleinlaan 2, B-1050, Brussels, Belgium
| |
Collapse
|
35
|
Measurement and Modeling of Extra-Column Effects Due to Injection and Connections in Capillary Liquid Chromatography. CHROMATOGRAPHY 2015. [DOI: 10.3390/chromatography2040669] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
36
|
Tanaka N, McCalley DV. Core–Shell, Ultrasmall Particles, Monoliths, and Other Support Materials in High-Performance Liquid Chromatography. Anal Chem 2015; 88:279-98. [DOI: 10.1021/acs.analchem.5b04093] [Citation(s) in RCA: 119] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Affiliation(s)
| | - David V. McCalley
- Centre for Research in Biosciences, University of the West of England, Frenchay, Bristol BS16 1QY, U.K
| |
Collapse
|
37
|
Gritti F, McDonald T, Gilar M. Impact of the column hardware volume on resolution in very high pressure liquid chromatography non-invasive investigations. J Chromatogr A 2015; 1420:54-65. [DOI: 10.1016/j.chroma.2015.09.079] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2015] [Revised: 09/24/2015] [Accepted: 09/24/2015] [Indexed: 12/28/2022]
|
38
|
Andrés A, Broeckhoven K, Desmet G. Methods for the experimental characterization and analysis of the efficiency and speed of chromatographic columns: A step-by-step tutorial. Anal Chim Acta 2015; 894:20-34. [DOI: 10.1016/j.aca.2015.08.030] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2015] [Revised: 08/08/2015] [Accepted: 08/13/2015] [Indexed: 11/26/2022]
|
39
|
Gritti F, McDonald T, Gilar M. Accurate measurement of dispersion data through short and narrow tubes used in very high-pressure liquid chromatography. J Chromatogr A 2015; 1410:118-28. [DOI: 10.1016/j.chroma.2015.07.086] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2015] [Revised: 07/20/2015] [Accepted: 07/22/2015] [Indexed: 11/16/2022]
|
40
|
Post column derivatisation analyses review. Is post-column derivatisation incompatible with modern HPLC columns? Anal Chim Acta 2015; 889:58-70. [DOI: 10.1016/j.aca.2015.07.003] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2015] [Revised: 07/02/2015] [Accepted: 07/05/2015] [Indexed: 12/12/2022]
|