Selmi H, Walker A, Debarbieux L, Schmitt-Kopplin P. Improving the intestinal lipidome coverage in a gnotobiotic mouse model using UHPLC-MS-based approach through optimization of mobile phase modifiers and column selection. J Chromatogr B Analyt Technol Biomed Life Sci 2024; 1242:124188. [PMID: 38901159 DOI: 10.1016/j.jchromb.2024.124188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2024] [Revised: 05/21/2024] [Accepted: 05/30/2024] [Indexed: 06/22/2024]
Abstract
Lipidomics is focusing on the screening of lipid species in complex mixtures using mass spectrometry-based approaches. In this work, we aim to enhance the intestinal lipidome coverage within the Oligo-Mouse-Microbiota (OMM12) colonized mouse model by testing eight mobile phase conditions on five reversed-phase columns. Our selected mobile phase modifiers included two ammonium salts, two concentrations, and the addition of respective acids at 0.1 %. We compared two columns with hybrid surface technology, two with ethylene bridged hybrid technology and one with core-shell particles. Best performance was attained for standards and intestinal lipidome, using either ammonium formate or acetate in ESI(+) or ammonium acetate in ESI(-) for all column technologies. Notably, a concentration of 5 mM ammonium salt showed optimal results for both modes, while the addition of acids had a negligible effect on lipid ionization efficiency. The HST BEH C18 column improved peak width and tailing factor parameters compared to other technologies. We achieved the highest lipid count in colon and ileum content, including ceramides, phosphatidylethanolamines and phosphatidylcholines, when using 5 mM ammonium acetate in ESI(-). Conversely, in ESI(+) 5 mM ammonium formate demonstrated superior coverage for diacylglycerols and triacylglycerols.
Collapse
Affiliation(s)
- Habiba Selmi
- Research Unit Analytical BioGeoChemistry, Helmholtz Zentrum München, Neuherberg, Germany
| | - Alesia Walker
- Research Unit Analytical BioGeoChemistry, Helmholtz Zentrum München, Neuherberg, Germany.
| | - Laurent Debarbieux
- Institut Pasteur, Université Paris Cité, CNRS UMR6047, Bacteriophage Bacterium Host, Paris, France
| | - Philippe Schmitt-Kopplin
- Research Unit Analytical BioGeoChemistry, Helmholtz Zentrum München, Neuherberg, Germany; Chair of Analytical Food Chemistry, Technical University of Munich, Freising, Germany
| |
Collapse
|
2
|
Bergmann D, Matarrita-Rodríguez J, Abdulla H. Toward a More Comprehensive Approach for Dissolved Organic Matter Chemical Characterization Using an Orbitrap Fusion Tribrid Mass Spectrometer Coupled with Ion and Liquid Chromatography Techniques. Anal Chem 2024; 96:3744-3753. [PMID: 38373907 PMCID: PMC10918622 DOI: 10.1021/acs.analchem.3c02599] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 01/02/2024] [Accepted: 01/02/2024] [Indexed: 02/21/2024]
Abstract
Dissolved organic matter (DOM) represents one of the largest active organic carbon pools in the global carbon cycle. Although extensively studied, only <10% of DOM has been chemically characterized into individual dissolved compounds due to its molecular complexity. This study introduced a more comprehensive DOM characterization method by coupling both ion chromatography (IC) and liquid chromatography (LC) with high mass accuracy and resolution mass spectrometry. We presented a new on-the-fly mass calibration of the Orbitrap technique by utilizing the "lock mass" function in the Orbitrap Fusion Tribrid mass spectrometer (OT-FTMS), which assures high mass accuracy at every scan by a postcolumn introduction of internal labeled standards. With both IC and LC, tested unlabeled standards of amino acids, small peptides, and organic acids were consistently below 1.0 ppm mass error, giving the OT-FTMS the potential of reaching mass accuracy of the Fourier-transform ion cyclotron resonance mass spectrometer. In addition to mass accuracy, a pooled quality control sample (QC) was used to increase reproducibility by applying systematic error removal using random forest (SERRF). Using an untargeted mass spectrometry approach, estuarine DOM samples were analyzed by OT-FTMS coupled to IC in negative mode and LC in positive mode detection to cover a wide range of highly cationic to highly anionic molecules. As a proof of concept, we focused on elucidating the structures of three distinct DOM compound classes with varied acidities and basicities. In UPLC-OT-FTMS, a total of 915 compounds were detected. We putatively elucidated 44 small peptides and 33 deaminated peptides of these compounds. With IC-OT-FTMS, a total of 1432 compounds were detected. We putatively elucidated 20 peptides, 268 deaminated peptides, and 188 organic acids. Except for five compounds, all putatively elucidated compounds were uniquely detected in their corresponding chromatography technique. These results highlight the need for combining these two techniques to provide a more comprehensive method for DOM characterization. Application of the combined IC and LC techniques is not limited to DOM chemical characterization. It can analyze other complex compound mixtures, such as metabolites, and anthropogenic pollutants, such as pesticides and endocrine-disrupting chemicals, in environmental and biological samples.
Collapse
Affiliation(s)
- Daniela Bergmann
- Department
of Physical and Environmental Sciences, Texas A&M University-Corpus Christi , Corpus Christi, Texas 78412, United States
| | - Jessie Matarrita-Rodríguez
- Department
of Physical and Environmental Sciences, Texas A&M University-Corpus Christi , Corpus Christi, Texas 78412, United States
- Centro
de Investigación en Contaminación Ambiental (CICA), Universidad de Costa Rica, San José 11501-2060, Costa Rica
| | - Hussain Abdulla
- Department
of Physical and Environmental Sciences, Texas A&M University-Corpus Christi , Corpus Christi, Texas 78412, United States
- Center
for Water Supply Studies, Texas A&M
University-Corpus Christi , Corpus Christi, Texas 78412, United States
| |
Collapse
|
3
|
Naplekov DK, Bárta P, Trejtnar F, Sklenářová H, Lenčo J. Implementing reversed-phase and hydrophilic interaction liquid chromatography into the characterization of DTPA-ramucirumab conjugate before radiolabeling. J Pharm Biomed Anal 2023; 235:115615. [PMID: 37566949 DOI: 10.1016/j.jpba.2023.115615] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Revised: 07/27/2023] [Accepted: 07/30/2023] [Indexed: 08/13/2023]
Abstract
Radioimmunoconjugates represent a promising class of therapeutics and diagnostics. The characterization of intermediate chelator-antibody products, i.e., without the radionuclide, is frequently omitted, bringing significant uncertainty in the radioimmunoconjugate preparation. In the present study, we explored the utility of reversed-phase (RPLC) and hydrophilic interaction (HILIC) liquid chromatography with UV detection to characterize ramucirumab stochastically conjugated with p-SCN-Bn-CHX-A"-DTPA chelator (shortly DTPA). The conjugation was well reflected in RPLC chromatograms, while chromatograms from HILIC were significantly less informative. RPLC analyses at the intact level confirmed that the conjugation resulted in a heterogeneous mixture of modified ramucirumab. Moreover, the RPLC of DTPA-ramucirumab confirmed heterogeneous conjugation of all subunits. The peptide mapping did not reveal substantial changes after the conjugation, indicating that most parts of ramucirumab molecules remained unmodified and that the DTPA chelator was bound to various sites. Eventually, the RPLC method for analysis of intact ramucirumab was successfully applied to online monitoring of conjugation reaction in 1 h intervals for a total of 24 h synthesis, which readily reflected the structural changes of ramucirumab in the form of retention time shift by 0.21 min and increase in peak width by 0.22 min. The results were obtained in real-time, practically under 10 min per monitoring cycle. To the best of our knowledge, our study represents the first evaluation of RPLC and HILIC to assess the quality of intermediates during the on-site preparation of radioimmunoconjugates prior to radiolabeling.
Collapse
Affiliation(s)
- Denis K Naplekov
- Charles University, Faculty of Pharmacy in Hradec Kralove, Department of Analytical Chemistry, Akademika Heyrovskeho 1203/8, 500 05 Hradec Kralove, Czech Republic
| | - Pavel Bárta
- Charles University, Faculty of Pharmacy in Hradec Kralove, Department of Biophysics and Physical Chemistry, Akademika Heyrovskeho 1203/8, 500 05 Hradec Kralove, Czech Republic
| | - František Trejtnar
- Charles University, Faculty of Pharmacy in Hradec Kralove, Department of Pharmacology and Toxicology, Akademika Heyrovskeho 1203/8, 500 05 Hradec Kralove, Czech Republic
| | - Hana Sklenářová
- Charles University, Faculty of Pharmacy in Hradec Kralove, Department of Analytical Chemistry, Akademika Heyrovskeho 1203/8, 500 05 Hradec Kralove, Czech Republic
| | - Juraj Lenčo
- Charles University, Faculty of Pharmacy in Hradec Kralove, Department of Analytical Chemistry, Akademika Heyrovskeho 1203/8, 500 05 Hradec Kralove, Czech Republic.
| |
Collapse
|
4
|
Taylor MR, Kawakami J, McCalley DV. Managing sample introduction problems in hydrophilic interaction liquid chromatography. J Chromatogr A 2023; 1700:464006. [PMID: 37167803 DOI: 10.1016/j.chroma.2023.464006] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2023] [Revised: 04/18/2023] [Accepted: 04/19/2023] [Indexed: 05/13/2023]
Abstract
Sample injection can cause serious problems in hydrophilic interaction liquid chromatography (HILIC) when the injection solvent has higher elution strength than the mobile phase (mp). It can lead to asymmetric peak shapes and poor efficiency. The problem can occur when the mp contains a high proportion of organic e.g. 95% acetonitrile (a weak solvent) whereas the injection solvent contains a higher proportion of water (a strong solvent) that is necessary to dissolve polar samples. We investigated different strategies to overcome this problem. A simple method is pre-column dilution where the injector is programmed to deliver a plug of weak solvent (e.g. pure acetonitrile) along with the sample dissolved in a solvent with higher water content than the mp. Another option is to use alternative organic solvents to acetonitrile in the injection solvent, e.g. isopropanol, acetone or tetrahydrofuran, that may give enhanced sample solubility. The role of the volume of injection solvents was investigated as well as the possible effects of mass overload on the results. The use of small sample volumes is always recommended to reduce mismatch effects.
Collapse
Affiliation(s)
- Mark R Taylor
- Pfizer Global Research and Development, Discovery Park, Ramsgate Road, Sandwich, CT13 9NJ, UK
| | - Jane Kawakami
- Pfizer Global Research and Development, 280 Shennecossett Rd, Groton, CT 06340, USA
| | - David V McCalley
- Centre for Research in Biosciences, University of the West of England, Frenchay, Bristol, BS16 1QY, UK.
| |
Collapse
|
5
|
Floros DJ, Xu K, Berthiller F, Schwartz-Zimmermann H. Comparison of chromatographic conditions for the targeted tandem mass spectrometric determination of 354 mammalian metabolites. J Chromatogr A 2023; 1697:463985. [PMID: 37062154 DOI: 10.1016/j.chroma.2023.463985] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Revised: 03/22/2023] [Accepted: 04/08/2023] [Indexed: 04/18/2023]
Abstract
Metabolomics is becoming increasingly popular in livestock research, but no single analytical method can cover the entire metabolome. As such, we compared similar and complementary chromatographic methods with respect to analyte coverage and chromatographic properties of mammalian metabolites. We investigated 354 biologically relevant primary metabolites from 19 compound classes including amino acids, bile acids, biogenic amines, carboxylic acids, lipids, nucleotides and sugars. A total of 2063 selected reaction monitoring transitions were optimized on a triple quadrupole mass spectrometer. We then determined the retention profiles and peak parameters of our compounds using an anion exchange chromatography (AIC), three reversed-phase (RP) and three hydrophilic interaction liquid chromatography (HILIC) methods. On average, HILIC methods covered 54% of all metabolites with retention factors >1, while average RP coverage was 41%. In contrast to RP, HILIC methods could also retain polar metabolites such as amino acids and biogenic amines. Carboxylic acids, nucleotides, and sugar related compounds were best separated by AIC or zwitterionic pHILIC with alkaline eluents. Combining two complementary HILIC and RP methods increased the library coverage to 92%. By further including important short chain fatty acids, a combination of HILIC, RP and AIC methods achieved a coverage of 97%. The resulting dataset of LC and MS/MS parameters will facilitate the development of tailor-made quantitative targeted LC-MS/MS methods to investigate the mammalian metabolome.
Collapse
Affiliation(s)
- Dimitrios J Floros
- Christian Doppler Laboratory for Innovative Gut Health Concepts of Livestock, Institute of Bioanalytics and Agro-Metabolomics, Department of Agrobiotechnology (IFA-Tulln), University of Natural Resources and Life Sciences, Vienna (BOKU), Konrad-Lorenz-Str. 20, 3430 Tulln, Austria
| | - Kangkang Xu
- Christian Doppler Laboratory for Innovative Gut Health Concepts of Livestock, Institute of Bioanalytics and Agro-Metabolomics, Department of Agrobiotechnology (IFA-Tulln), University of Natural Resources and Life Sciences, Vienna (BOKU), Konrad-Lorenz-Str. 20, 3430 Tulln, Austria
| | - Franz Berthiller
- Christian Doppler Laboratory for Innovative Gut Health Concepts of Livestock, Institute of Bioanalytics and Agro-Metabolomics, Department of Agrobiotechnology (IFA-Tulln), University of Natural Resources and Life Sciences, Vienna (BOKU), Konrad-Lorenz-Str. 20, 3430 Tulln, Austria.
| | - Heidi Schwartz-Zimmermann
- Christian Doppler Laboratory for Innovative Gut Health Concepts of Livestock, Institute of Bioanalytics and Agro-Metabolomics, Department of Agrobiotechnology (IFA-Tulln), University of Natural Resources and Life Sciences, Vienna (BOKU), Konrad-Lorenz-Str. 20, 3430 Tulln, Austria
| |
Collapse
|
6
|
Lin YT, Chan SA, Chen YJ, Chung KP, Kuo CH. Using an In-Sample Addition of Medronic Acid for the Analysis of Purine- and Pyrimidine-Related Derivatives and Its Application in the Study of Lung Adenocarcinoma A549 Cell Lines by LC-MS/MS. J Proteome Res 2023; 22:1434-1445. [PMID: 36930966 DOI: 10.1021/acs.jproteome.2c00736] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/19/2023]
Abstract
Intracellular purine- and pyrimidine-related derivatives are vital molecules for preserving genetic information and are essential for cellular bioenergetics and signal transduction. This study developed a practical liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantifying intracellular purine- and pyrimidine-related derivatives. To solve the distorted peak shape related to di- and triphosphate nucleotides, in-sample addition of medronic acid and ammonium phosphate was performed. Using the BEH-amide column, the results showed that adding 0.5 mM medronic acid to the sample significantly improved the peak shape without causing an obvious ion suppressive effect. Method validation confirmed that the coefficients of determination (R2) values for linearity evaluation were above 0.94 for all analytes. The intraday and interday accuracies ranged from 85.1 to 128.4%, with the precision below 16.6%. The validated method was successfully applied in characterizing the alterations of purine- and pyrimidine-related derivatives in the A549 cell line with perturbed mitochondrial fission or blockade of the electron transport chain. Collectively, this study demonstrates that the strategy of in-sample medronic acid addition is effective in improving the quantification of intracellular purine- and pyrimidine-related derivatives. We believe that our proposed platform can facilitate the development of novel drugs targeting purine and pyrimidine metabolism in the future.
Collapse
Affiliation(s)
- Ya-Ting Lin
- School of Pharmacy, College of Medicine, National Taiwan University, Taipei 100, Taiwan.,The Metabolomics Core Laboratory, Center of Genomic and Precision Medicine, National Taiwan University, Taipei 100, Taiwan
| | | | - Yi-Jung Chen
- Department of Laboratory Medicine, College of Medicine, National Taiwan University, Taipei 100, Taiwan
| | - Kuei-Pin Chung
- Department of Laboratory Medicine, National Taiwan University Hospital and College of Medicine, National Taiwan University, Taipei 100, Taiwan
| | - Ching-Hua Kuo
- School of Pharmacy, College of Medicine, National Taiwan University, Taipei 100, Taiwan.,The Metabolomics Core Laboratory, Center of Genomic and Precision Medicine, National Taiwan University, Taipei 100, Taiwan.,Department of Pharmacy, National Taiwan University Hospital, Taipei 100, Taiwan
| |
Collapse
|
7
|
Xin R, Dong M, Zhang YY, Huang XH, Dong XP, Qin L. Development and Validation of a HILIC-MS/MS Method for Simultaneous Quantitative of Taste-active Compounds in Foods. J Food Compost Anal 2023. [DOI: 10.1016/j.jfca.2023.105302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/03/2023]
|
8
|
Lohse M, Santangeli M, Steininger-Mairinger T, Oburger E, Reemtsma T, Lechtenfeld OJ, Hann S. The effect of root hairs on exudate composition: a comparative non-targeted metabolomics approach. Anal Bioanal Chem 2023; 415:823-840. [PMID: 36547703 PMCID: PMC9883335 DOI: 10.1007/s00216-022-04475-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2022] [Revised: 11/10/2022] [Accepted: 12/05/2022] [Indexed: 12/24/2022]
Abstract
Root exudation is a major pathway of organic carbon input into soils. It affects soil physical properties, element solubility as well as speciation, and impacts the microbial community in the rhizosphere. Root exudates contain a large number of primary and secondary plant metabolites, and the amount and composition are highly variable depending on plant species and developmental stage. Detailed information about exudate composition will allow for a better understanding of exudate-driven rhizosphere processes and their feedback loops. Although non-targeted metabolomics by high-resolution mass spectrometry is an established tool to characterize root exudate composition, the extent and depth of the information obtained depends strongly on the analytical approach applied. Here, two genotypes of Zea mays L., differing in root hair development, were used to compare six mass spectrometric approaches for the analysis of root exudates. Reversed-phase liquid chromatography and hydrophilic interaction liquid chromatography combined with time-of-flight mass spectrometry (LC-TOF-MS), as well as direct infusion Fourier-transform ion cyclotron resonance mass spectrometry (DI-FT-ICR-MS), were applied with positive and negative ionization mode. By using the same statistical workflow, the six approaches resulted in different numbers of detected molecular features, ranging from 176 to 889, with a fraction of 48 to 69% of significant features (fold change between the two genotypes of > 2 and p-value < 0.05). All approaches revealed the same trend between genotypes, namely up-regulation of most metabolites in the root hair defective mutant (rth3). These results were in agreement with the higher total carbon and nitrogen exudation rate of the rth3-mutant as compared to the corresponding wild-type maize (WT). However, only a small fraction of features were commonly found across the different analytical approaches (20-79 features, 13-31% of the rth3-mutant up-regulated molecular formulas), highlighting the need for different mass spectrometric approaches to obtain a more comprehensive view into the composition of root exudates. In summary, 111 rth3-mutant up-regulated compounds (92 different molecular formulas) were detected with at least two different analytical approaches, while no WT up-regulated compound was found by both, LC-TOF-MS and DI-FT-ICR-MS. Zea mays L. exudate features obtained with multiple analytical approaches in our study were matched against the metabolome database of Zea mays L. (KEGG) and revealed 49 putative metabolites based on their molecular formula.
Collapse
Affiliation(s)
- Martin Lohse
- Department of Analytical Chemistry, Helmholtz Centre for Environmental Research - UFZ, 04318, Leipzig, Germany
| | - Michael Santangeli
- Department of Forest and Soil Sciences, Institute of Soil Research, University of Natural Resources and Life Sciences, Vienna (BOKU), 3430, Tulln an Der Donau, Austria
- Department of Chemistry, Institute of Analytical Chemistry, University of Natural Resources and Life Sciences, Vienna (BOKU), 1190, Vienna, Austria
| | - Teresa Steininger-Mairinger
- Department of Chemistry, Institute of Analytical Chemistry, University of Natural Resources and Life Sciences, Vienna (BOKU), 1190, Vienna, Austria
| | - Eva Oburger
- Department of Forest and Soil Sciences, Institute of Soil Research, University of Natural Resources and Life Sciences, Vienna (BOKU), 3430, Tulln an Der Donau, Austria.
| | - Thorsten Reemtsma
- Department of Analytical Chemistry, Helmholtz Centre for Environmental Research - UFZ, 04318, Leipzig, Germany
- Institute of Analytical Chemistry, University of Leipzig, 04103, Leipzig, Germany
| | - Oliver J Lechtenfeld
- Department of Analytical Chemistry, Helmholtz Centre for Environmental Research - UFZ, 04318, Leipzig, Germany.
- ProVIS, Centre for Chemical Microscopy, Helmholtz Centre for Environmental Research, UFZ, 04318, Leipzig, Germany.
| | - Stephan Hann
- Department of Chemistry, Institute of Analytical Chemistry, University of Natural Resources and Life Sciences, Vienna (BOKU), 1190, Vienna, Austria
| |
Collapse
|
9
|
Lenčo J, Jadeja S, Naplekov DK, Krokhin OV, Khalikova MA, Chocholouš P, Urban J, Broeckhoven K, Nováková L, Švec F. Reversed-Phase Liquid Chromatography of Peptides for Bottom-Up Proteomics: A Tutorial. J Proteome Res 2022; 21:2846-2892. [PMID: 36355445 DOI: 10.1021/acs.jproteome.2c00407] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The performance of the current bottom-up liquid chromatography hyphenated with mass spectrometry (LC-MS) analyses has undoubtedly been fueled by spectacular progress in mass spectrometry. It is thus not surprising that the MS instrument attracts the most attention during LC-MS method development, whereas optimizing conditions for peptide separation using reversed-phase liquid chromatography (RPLC) remains somewhat in its shadow. Consequently, the wisdom of the fundaments of chromatography is slowly vanishing from some laboratories. However, the full potential of advanced MS instruments cannot be achieved without highly efficient RPLC. This is impossible to attain without understanding fundamental processes in the chromatographic system and the properties of peptides important for their chromatographic behavior. We wrote this tutorial intending to give practitioners an overview of critical aspects of peptide separation using RPLC to facilitate setting the LC parameters so that they can leverage the full capabilities of their MS instruments. After briefly introducing the gradient separation of peptides, we discuss their properties that affect the quality of LC-MS chromatograms the most. Next, we address the in-column and extra-column broadening. The last section is devoted to key parameters of LC-MS methods. We also extracted trends in practice from recent bottom-up proteomics studies and correlated them with the current knowledge on peptide RPLC separation.
Collapse
Affiliation(s)
- Juraj Lenčo
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05Hradec Králové, Czech Republic
| | - Siddharth Jadeja
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05Hradec Králové, Czech Republic
| | - Denis K Naplekov
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05Hradec Králové, Czech Republic
| | - Oleg V Krokhin
- Department of Internal Medicine, Manitoba Centre for Proteomics and Systems Biology, University of Manitoba, 799 JBRC, 715 McDermot Avenue, WinnipegR3E 3P4, Manitoba, Canada
| | - Maria A Khalikova
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05Hradec Králové, Czech Republic
| | - Petr Chocholouš
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05Hradec Králové, Czech Republic
| | - Jiří Urban
- Department of Chemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00Brno, Czech Republic
| | - Ken Broeckhoven
- Department of Chemical Engineering (CHIS), Faculty of Engineering, Vrije Universiteit Brussel, Pleinlaan 2, 1050Brussel, Belgium
| | - Lucie Nováková
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05Hradec Králové, Czech Republic
| | - František Švec
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05Hradec Králové, Czech Republic
| |
Collapse
|
10
|
Lardeux H, Goyon A, Zhang K, Nguyen JM, Lauber MA, Guillarme D, D'Atri V. The impact of low adsorption surfaces for the analysis of DNA and RNA oligonucleotides. J Chromatogr A 2022; 1677:463324. [PMID: 35858489 DOI: 10.1016/j.chroma.2022.463324] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Revised: 07/07/2022] [Accepted: 07/08/2022] [Indexed: 12/20/2022]
Abstract
As interest in oligonucleotide (ON) therapeutics is increasing, there is a need to develop suitable analytical methods able to properly analyze those molecules. However, an issue exists in the adsorption of ONs on different parts of the instrumentation during their analysis. The goal of the present paper was to comprehensively evaluate various types of bioinert materials used in ion-pairing reversed-phase (IP-RPLC) and hydrophilic interaction chromatography (HILIC) to mitigate this issue for 15- to 100-mer DNA and RNA oligonucleotides. The whole sample flow path was considered under both conditions, including chromatographic columns, ultra-high-performance liquid chromatography (UHPLC) system, and ultraviolet (UV) flow cell. It was found that a negligible amount of non-specific adsorption might be attributable to the chromatographic instrumentation. However, the flow cell of a detector should be carefully subjected to sample-based conditioning, as the material used in the UV flow cell was found to significantly impact the peak shapes of the largest ONs (60- to 100-mer). Most importantly, we found that the choice of column hardware had the most significant impact on the extent of non-specific adsorption. Depending on the material used for the column walls and frits, adsorption can be more or less pronounced. It was proved that any type of bioinert RPLC/HILIC column hardware offered some clear benefits in terms of adsorption in comparison to their stainless-steel counterparts. Finally, the evaluation of a large set of ONs was performed, including a DNA duplex and DNA or RNA ONs having different base composition, furanose sugar, and modifications occurring at the phosphate linkage or at the sugar moiety. This work represents an important advance in understanding the overall ON adsorption, and it helps to define the best combination of materials when analyzing a wide range of unmodified and modified 20-mer DNA and RNA ONs.
Collapse
Affiliation(s)
- Honorine Lardeux
- Institute of Pharmaceutical Sciences of Western Switzerland (ISPSO), University of Geneva, CMU-Rue Michel Servet 1, Geneva 4 1211, Switzerland; School of Pharmaceutical Sciences, University of Geneva, CMU-Rue Michel Servet 1, Geneva 4 1211, Switzerland
| | - Alexandre Goyon
- Small Molecule Pharmaceutical Sciences, Genentech Inc., DNA Way, South San Francisco, CA 94080, USA
| | - Kelly Zhang
- Small Molecule Pharmaceutical Sciences, Genentech Inc., DNA Way, South San Francisco, CA 94080, USA
| | | | | | - Davy Guillarme
- Institute of Pharmaceutical Sciences of Western Switzerland (ISPSO), University of Geneva, CMU-Rue Michel Servet 1, Geneva 4 1211, Switzerland; School of Pharmaceutical Sciences, University of Geneva, CMU-Rue Michel Servet 1, Geneva 4 1211, Switzerland
| | - Valentina D'Atri
- Institute of Pharmaceutical Sciences of Western Switzerland (ISPSO), University of Geneva, CMU-Rue Michel Servet 1, Geneva 4 1211, Switzerland; School of Pharmaceutical Sciences, University of Geneva, CMU-Rue Michel Servet 1, Geneva 4 1211, Switzerland.
| |
Collapse
|
11
|
Walter TH, Alden BA, Belanger JL, Berthelette K, Boissel C, DeLano M, Kizekai L, Nguyen JM, Shiner SJ. Modifying the Metal Surfaces in HPLC Systems and Columns to Prevent Analyte Adsorption and Other Deleterious Effects. LCGC NORTH AMERICA 2022. [DOI: 10.56530/lcgc.na.pm7270x6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Interactions of certain analytes with metal surfaces in high performance liquid chromatography (HPLC) instruments and columns cause a range of deleterious effects, including peak broadening and tailing, low peak areas, and the formation of new peaks due to chemical reactions. To mitigate these effects, we have developed a novel surface modification technology in which a hybrid organic/inorganic surface based on an ethylene-bridged siloxane chemistry is applied to the metal components in HPLC instruments and columns. We demonstrate the impact of this technology on peak symmetry, peak area, and injection-to-injection and column-to-column reproducibility for several metal-sensitive analytes. We also show an example of the mitigation of an on-column oxidation reaction. A variant of this technology has recently been developed for size-exclusion chromatography of proteins. An example is shown demonstrating the use of this variant applied to size-exclusion columns for the separation of a monoclonal antibody monomer and higher molecular weight species. Together, these results highlight the importance of preventing interactions of analytes with metal surfaces in HPLC in order to achieve accurate and precise results.
Collapse
|
12
|
Koley S, Chu KL, Gill SS, Allen DK. An efficient LC-MS method for isomer separation and detection of sugars, phosphorylated sugars, and organic acids. JOURNAL OF EXPERIMENTAL BOTANY 2022; 73:2938-2952. [PMID: 35560196 DOI: 10.1093/jxb/erac062] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2021] [Accepted: 02/15/2022] [Indexed: 06/15/2023]
Abstract
Assessing central carbon metabolism in plants can be challenging due to the dynamic range in pool sizes, with low levels of important phosphorylated sugars relative to more abundant sugars and organic acids. Here, we report a sensitive liquid chromatography-mass spectrometry method for analysing central metabolites on a hybrid column, where both anion-exchange and hydrophilic interaction chromatography (HILIC) ligands are embedded in the stationary phase. The liquid chromatography method was developed for enhanced selectivity of 27 central metabolites in a single run with sensitivity at femtomole levels observed for most phosphorylated sugars. The method resolved phosphorylated hexose, pentose, and triose isomers that are otherwise challenging. Compared with a standard HILIC approach, these metabolites had improved peak areas using our approach due to ion enhancement or low ion suppression in the biological sample matrix. The approach was applied to investigate metabolism in high lipid-producing tobacco leaves that exhibited increased levels of acetyl-CoA, a precursor for oil biosynthesis. The application of the method to isotopologue detection and quantification was considered through evaluating 13C-labeled seeds from Camelina sativa. The method provides a means to analyse intermediates more comprehensively in central metabolism of plant tissues.
Collapse
Affiliation(s)
- Somnath Koley
- Donald Danforth Plant Science Center, St Louis, MO 63132, USA
| | - Kevin L Chu
- Donald Danforth Plant Science Center, St Louis, MO 63132, USA
- United States Department of Agriculture-Agriculture Research Service, Donald Danforth Plant Science Center, St Louis, MO 63132, USA
| | - Saba S Gill
- Donald Danforth Plant Science Center, St Louis, MO 63132, USA
- United States Department of Agriculture-Agriculture Research Service, Donald Danforth Plant Science Center, St Louis, MO 63132, USA
| | - Doug K Allen
- Donald Danforth Plant Science Center, St Louis, MO 63132, USA
- United States Department of Agriculture-Agriculture Research Service, Donald Danforth Plant Science Center, St Louis, MO 63132, USA
| |
Collapse
|
13
|
Kohler I, Verhoeven M, Haselberg R, Gargano AF. Hydrophilic interaction chromatography – mass spectrometry for metabolomics and proteomics: state-of-the-art and current trends. Microchem J 2022. [DOI: 10.1016/j.microc.2021.106986] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
14
|
Application of hybrid surface technology for improving sensitivity and peak shape of phosphorylated lipids such as phosphatidic acid and phosphatidylserine. J Chromatogr A 2022; 1669:462921. [PMID: 35272103 DOI: 10.1016/j.chroma.2022.462921] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 02/21/2022] [Accepted: 02/24/2022] [Indexed: 11/23/2022]
Abstract
The use of hybrid surface technology (HST), applied to the metal surfaces of an ACQUITY™ UPLC™ system and column, designed to mitigate the chelation, poor peak shape and analyte loss seen with acidic phospholipids was investigated. Compared to a conventional system significant improvements in both sensitivity, recovery and peak shape were obtained following UPLC on a CSH C18 column when the HST was used for the analysis of lysophosphatidic acid (LPA), phosphatidic acid (PA), lysophosphatidylserine (LPS), phosphatidylserine (PS), phosphatidylinositol-monophosphates (PIP), ceramide phosphate (CerP) and sphingoid base phosphate (SPBP). The benefits in chromatographic performance provided by the HST were seen particularly at low concentrations of these analytes. The HST system and column reduced peak tailing by 65-80% and peak width by 70-86% for LPA and PA. Moreover, increased signal intensities of up to 12.7 times were observed for LPA with the HST approach compared to the equivalent untreated LC system and column. The application of this methodology to the analysis of chicken egg PA and brain porcine PS extracts were accompanied by similar improvements in data quality.
Collapse
|
15
|
Peng KW, Klotz A, Guven A, Gray K, Friss T, Ravipaty S, Sarangarajan R, Tolstikov V, Kellogg MD, Narain NR, Kiebish MA. Multiplexed LC-MS/MS analysis of methylsuccinic acid, ethylmalonic acid, and glutaric acid in plasma and urine. Anal Biochem 2022; 645:114604. [PMID: 35217005 DOI: 10.1016/j.ab.2022.114604] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Revised: 02/08/2022] [Accepted: 02/11/2022] [Indexed: 11/01/2022]
Abstract
Low molecular-mass aliphatic carboxylic acids are critically important for intermediate metabolism and may serve as important biomarkers for metabolic homeostasis. Here in, we focused on multiplexed method development of aliphatic carboxylic analytes, including methylsuccinic acid (MSA), ethylmalonic acid (EMA), and glutaric acid (GA). Also assessed was their utility in a population's health as well as metabolic disease screening in both plasma and urine matrices. MSA, EMA, and GA are constitutional isomers of dicarboxylic acid with high polarity and poor ionization efficiency, resulting in such challenges as poor signal intensity and retention, particularly in reversed-phase liquid chromatography with electrospray mass spectrometry (RP-LC-ESI-MS/MS). Derivatization using n-butanol was performed in the sample preparation to enhance the signal intensity accompanied with a positive charge from ionization in complicated biomatrices as well as to improve the separation of these isomers with optimal retention. Fit-for-purpose method validation results demonstrated quantitative ranges for MSA/EMA/GA from 5/10/20 ng/mL to 400 ng/mL in plasma analysis, and 100/200/100 ng/mL to 5000/10000/5000 ng/mL in urine analysis. This validated method demonstrates future utility when exploring population health analysis and biomarker development in metabolic diseases.
Collapse
Affiliation(s)
- Kuan-Wei Peng
- BERG, 500 Old Connecticut Path, Framingham, MA, 01701, USA
| | - Allison Klotz
- BERG, 500 Old Connecticut Path, Framingham, MA, 01701, USA
| | - Arcan Guven
- BERG, 500 Old Connecticut Path, Framingham, MA, 01701, USA
| | - Kayleigh Gray
- BERG, 500 Old Connecticut Path, Framingham, MA, 01701, USA
| | - Tracey Friss
- BERG, 500 Old Connecticut Path, Framingham, MA, 01701, USA
| | | | | | | | - Mark D Kellogg
- BERG, 500 Old Connecticut Path, Framingham, MA, 01701, USA; Department of Pathology, Harvard Medical School, Boston, MA, USA; Department of Laboratory Medicine, Boston Children's Hospital, 300 Longwood Avenue, Boston, MA, 02115, USA
| | - Niven R Narain
- BERG, 500 Old Connecticut Path, Framingham, MA, 01701, USA
| | | |
Collapse
|
16
|
McCalley DV. Influence of metals in the column or instrument on performance in hydrophilic interaction liquid chromatography. J Chromatogr A 2022; 1663:462751. [PMID: 34995861 DOI: 10.1016/j.chroma.2021.462751] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2021] [Revised: 12/13/2021] [Accepted: 12/13/2021] [Indexed: 10/19/2022]
Abstract
A method is proposed for measuring the relative contribution of extracolumn and column effects to the detrimental interactions which occur between metal-sensitive solutes and the complete HPLC system. The method involves the substitution of a length of narrow bore silica tubing for the column and measuring the extracolumn contribution, which is subtracted from the total bandspreading measured with a column in place to yield the column contribution. The investigation focussed on HILIC separations, which have been relatively little studied compared with similar effects in RPLC. Metal-solute interactions can lead to tailing peaks and reduced sensitivity or even irreversible adsorption of particularly challenging solutes such as mono-, di- and triphosphorylated nucleotides, which show strong interactions between their phosphate groups and metals. A deactivated HILIC column, treated by a vapour deposition procedure gave generally good results when using high pH (pH 9.0) mobile phases, which suppress the effects of metals. The addition of metal complexing agents such as citrate at low millimolar concentration gave further improvements in peak shape at high pH, and even micromolar concentrations of citrate or medronic acid showed good results. These lower concentrations are more favourable for LC-MS. Addition of the higher concentration of citrate gave acceptable results for the nucleotides even at low pH (pH 3.0). With the standard UHPLC instrument used, loss of efficiency due to metal solute interactions was 25% or less, with most losses due to interactions with the column, although this result will depend on the condition and design of the instrument, which is easily assessed by the proposed procedure.
Collapse
Affiliation(s)
- David V McCalley
- Centre for Research in Biosciences, University of the West of England, Frenchay, Coldharbour Lane, Bristol BS16 1QY, United Kingdom.
| |
Collapse
|
17
|
Walter TH, Alden BA, Berthelette K, Field JA, Lawrence NL, McLaughlin J, Patel AV. Characterization of a highly stable zwitterionic hydrophilic interaction chromatography stationary phase based on hybrid organic/inorganic particles. J Sep Sci 2021; 45:1389-1399. [PMID: 34937126 PMCID: PMC9487986 DOI: 10.1002/jssc.202100859] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Revised: 12/14/2021] [Accepted: 12/16/2021] [Indexed: 11/08/2022]
Abstract
We have characterized a sulfobetaine stationary phase based on 1.7 μm ethylene-bridged hybrid organic/inorganic particles, which is intended for use in hydrophilic interaction chromatography. The efficiency of columns packed with this material were determined as a function of flow rate, demonstrating a minimum reduced plate height of 2.4. The batch-to-batch reproducibility was assessed using the separation of a mixture of acids, bases and neutrals. We compared the retention and selectivity of the hybrid sulfobetaine stationary phase to that of several benchmark materials. The hybrid sulfobetaine material gave strong retention for polar neutrals and high selectivity for methyl groups, hydroxy groups and configurational isomers. Large differences in cation and anion retention were observed among the columns. We characterized the acid and base stability of the hybrid sulfobetaine stationary phase, using accelerated tests at pH 1.3 and 11.0, both at 70°C. The results support a recommended pH range of 2 to 10. We also investigated the performance of columns packed with this material for metal-sensitive analytes, comparing conventional stainless steel column hardware to hardware that incorporates hybrid surface technology to mitigate interactions with metal surfaces. Compared to the conventional columns, the hybrid surface technology columns showed greatly improved peak shape. This article is protected by copyright. All rights reserved.
Collapse
|
18
|
Violi JP, Bishop DP, Padula MP, Westerhausen MT, Rodgers KJ. Acetonitrile adduct analysis of underivatised amino acids offers improved sensitivity for hydrophilic interaction liquid chromatography tandem mass-spectrometry. J Chromatogr A 2021; 1655:462530. [PMID: 34517165 DOI: 10.1016/j.chroma.2021.462530] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Revised: 08/31/2021] [Accepted: 08/31/2021] [Indexed: 10/20/2022]
Abstract
LC-MS/MS method development for native amino acid detection can be problematic due to low ionisation efficiencies, in source fragmentation, potential for cluster ion formation and incorrect application of chromatography techniques. This has led to the majority of the scientific community derivatising amino acids for more sensitive analysis. Derivatisation has several benefits including reduced signal-to-noise ratios, more efficient ionisation, and a change in polarity, allowing the use of reverse phase chromatography. However, derivatisation of amino acids can be expensive, requires additional sample preparation steps, is more time consuming and increases sample instability, due to the most derivatised amino acids only be stable for finite amount of time. While showing initial promise, development of reliable hydrophilic interaction liquid chromatography (HILIC) separation methods has presented difficulties for the analyst including irreproducible separation and poor sensitivity. This study aimed to find a means to improve the detection sensitivity of the 20 protein amino acids by HILIC-MS/MS. We describe the use of previously undescribed amino acid-acetonitrile (ACN) adducts to improve detection of 16 out of the 20 amino acids. While all amino acids examined did form an ACN adduct, 4 had low intensity adduct formation compared to their protonated state, 3 of which are classified as basic amino acids. For 15 of the 20 amino acids tested, we used the ACN adduct for both quantification and qualification ions and demonstrated a significant enhancement in signal-to-noise ratio, ranging from 23 to 1762% improvement. Lower LODs, LOQs and lower ranges of linearity were also achieved for these amino acids. The optimised method was applied to a human neuroblastoma cell line (SH-SY5Y) with the potential to be applied to other complex sample types. The improved sensitivity this method offers simplifies sample preparation and reduces the costs of amino acid analysis compared to those methods that rely on derivatisation for sensitivity.
Collapse
Affiliation(s)
- Jake P Violi
- School of Life Sciences, Faculty of Science, The University of Technology Sydney, Ultimo 2007, Australia
| | - David P Bishop
- School of Mathematical and Physical Sciences, Faculty of Science, The University of Technology Sydney, Ultimo 2007, Australia
| | - Matthew P Padula
- School of Life Sciences, Faculty of Science, The University of Technology Sydney, Ultimo 2007, Australia
| | - Mika T Westerhausen
- School of Mathematical and Physical Sciences, Faculty of Science, The University of Technology Sydney, Ultimo 2007, Australia
| | - Kenneth J Rodgers
- School of Life Sciences, Faculty of Science, The University of Technology Sydney, Ultimo 2007, Australia.
| |
Collapse
|
19
|
Birdsall RE, Kellett J, Ippoliti S, Ranbaduge N, Lauber MA, Yu YQ, Chen W. Reducing metal-ion mediated adsorption of acidic peptides in RPLC-based assays using hybrid silica chromatographic surfaces. J Chromatogr B Analyt Technol Biomed Life Sci 2021; 1179:122700. [PMID: 34329890 DOI: 10.1016/j.jchromb.2021.122700] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Revised: 03/05/2021] [Accepted: 04/02/2021] [Indexed: 10/21/2022]
Abstract
In this study we evaluate column hardware exhibiting a novel hybrid silica surface in its ability to mitigate metal-induced adsorption artifacts such as chromatographic peak tailing for acidic amino acid residue containing peptides. Using a conventional reversed-phase liquid chromatography (RPLC)-based method, chromatographic performance of a peptide map was compared using a traditional stainless-steel column and an equivalent column bearing a novel hybrid silica surface. Tailing factors for six peptides containing acidic amino acid residues (Tf ≥ 1.50) were observed to be reduced up to 80% to a nominal value Tf ≤ 1.2 with R.S.D. % ≤ 4%. Furthermore, recovery for two of the identified peptides exhibited increased recovery in addition to reduced peak tailing when using the column bearing the hybrid silica surface. Performance was unaffected for peaks where there were no implications of metal induced effects. Collectively, this study demonstrates that the novel hybrid silica surface can effectively reduce peak tailing for acidic residue containing peptides.
Collapse
Affiliation(s)
- Robert E Birdsall
- Waters Corporation, 34 Maple Street, Milford, MA 01757, United States.
| | - Jacob Kellett
- Waters Corporation, 34 Maple Street, Milford, MA 01757, United States.
| | - Samantha Ippoliti
- Waters Corporation, 34 Maple Street, Milford, MA 01757, United States.
| | - Nilini Ranbaduge
- Waters Corporation, 34 Maple Street, Milford, MA 01757, United States.
| | - Matthew A Lauber
- Waters Corporation, 34 Maple Street, Milford, MA 01757, United States.
| | - Ying Qing Yu
- Waters Corporation, 34 Maple Street, Milford, MA 01757, United States.
| | - Weibin Chen
- Waters Corporation, 34 Maple Street, Milford, MA 01757, United States.
| |
Collapse
|
20
|
Tanna N, Mullin LG, Rainville PD, Wilson ID, Plumb RS. Improving LC/MS/MS-based bioanalytical method performance and sensitivity via a hybrid surface barrier to mitigate analyte - Metal surface interactions. J Chromatogr B Analyt Technol Biomed Life Sci 2021; 1179:122825. [PMID: 34218093 DOI: 10.1016/j.jchromb.2021.122825] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Revised: 06/01/2021] [Accepted: 06/03/2021] [Indexed: 12/16/2022]
Abstract
The accurate determination of the pharmacokinetics (PK) of a candidate drug molecule is critical in both drug discovery and development. Over the last 30 years, the sensitivity and selectivity of LC/MS has resulted in it being established as the technology of choice for these studies. However, unwanted chemical interactions between analyte(s) and the metal components in a chromatography system can result in poor peak shape and reduction in signal response, which can adversely affect the analysis of low concentrations of drugs and their metabolites in biological samples. This study evaluated the benefits of employing an inert hybrid surface technology (HST) applied to the metallic components in the LC flow path, column frits and column wall to mitigate these interactions. The results obtained were compared with that of an identical conventional LC for the bioanalysis of two steroid phosphate drugs (dexamethasone phosphate and hydrocortisone phosphate) and an epidermal growth factor receptor (EGFR) inhibitor (gefitinib) in human plasma. The results showed that for the two steroid phosphates, the peak width was reduced by 20%, peak tailing factors reduced by up to 30% and the assay sensitivity improved by factors of 7.5 and 10. This resulted in a significant improvement in the limit of detection. The new LC system also improved the reproducibility of peak integration for gefitinib, thereby reducing assay coefficients of variation (%CV) from greater than 10% to less than 5% at the lower limit of quantification.
Collapse
Affiliation(s)
- Nikunj Tanna
- Waters Corporation, 34 Maple St, Milford, MA 01757, USA.
| | - Lauren G Mullin
- Waters Corporation, Stamford Avenue, Altrincham Road, Wilmslow SK9 4AX, UK
| | | | - Ian D Wilson
- Computational and Systems Medicine, Department of Metabolism, Digestion and Reproduction Imperial College, London SW7 2AZ, UK
| | | |
Collapse
|
21
|
Gilar M, DeLano M, Gritti F. Mitigation of analyte loss on metal surfaces in liquid chromatography. J Chromatogr A 2021; 1650:462247. [PMID: 34087520 DOI: 10.1016/j.chroma.2021.462247] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Revised: 04/21/2021] [Accepted: 05/07/2021] [Indexed: 10/21/2022]
Abstract
The adsorptive loss of acidic analytes in liquid chromatography was investigated using metal frits. Repetitive injections of acidic small molecules or an oligonucleotide were made on individual 2.1 or 4.6 mm i.d. column frits. Losses were observed for adenosine 5'-(α,β-methylene) diphosphate, 2-pyridinol 1-oxide and the 25-mer phosphorothioate oligonucleotide Trecovirsen (GEM91) on stainless steel and titanium frits. Analyte adsorption was greatest at acidic pH due to the positive charge on the metal oxide surface. Analyte recovery increased when a series of injections was performed; this effect is known as sample conditioning. Nearly complete recovery was achieved when the metal adsorptive sites were saturated with the analyte. A similar effect was achieved by conditioning the frits with phosphoric, citric or etidronic acids, or their buffered solutions. These procedures can be utilized to mitigate analyte loss. However, the effect is temporary, as the conditioning agent is gradually removed by the running mobile phase. Metal frits modified with hybrid organic/inorganic surface technology were shown to mitigate analyte-to-metal surface interactions and improve recovery of acidic analytes. Quantitative recovery of a 15-35 mer oligodeoxythymidine mixture was achieved using column hardware modified with hybrid surface technology, without a need for column conditioning prior to analysis.
Collapse
Affiliation(s)
- Martin Gilar
- Waters Corporation, 34 Maple Street, Milford, MA 01757, USA.
| | - Mathew DeLano
- Waters Corporation, 34 Maple Street, Milford, MA 01757, USA
| | - Fabrice Gritti
- Waters Corporation, 34 Maple Street, Milford, MA 01757, USA
| |
Collapse
|
22
|
Plumb RS, Gethings LA, King A, Mullin LG, Maker G, Trengove R, Wilson ID. Hybrid organic/inorganic hybrid surface technology for increasing the performance of LC/MS(MS)-based drug metabolite identification studies: Application to gefitinib and metabolites in mouse plasma and urine. J Pharm Biomed Anal 2021; 200:114076. [PMID: 33892395 DOI: 10.1016/j.jpba.2021.114076] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Revised: 03/29/2021] [Accepted: 04/12/2021] [Indexed: 11/18/2022]
Abstract
The detection, identification and quantification of drug metabolites plays a key role in drug discovery and development. Liquid chromatography (LC) coupled to mass spectrometry (MS) has become the primary technology for these studies due to its sensitivity and specificity. However, the presence of transition metals in the chromatography system and columns can result in non-specific and unwanted interactions with the drug and/or its metabolites, via electron-pair donation, leading to poor chromatography and analyte loss. The use of a hybrid organic/inorganic surface applied to the metal surfaces of the chromatography system and column has been demonstrated to reduce or eliminate these effects. When employed for the analysis of mouse urine, derived from the oral dosing of mice with the EGFR inhibitor gefitinib, we observed more symmetrical LC peaks. This resulted in a 33 % improvement in peak capacity for a 10 min reversed - phase gradient separation, a two-fold increase in MS response, cleaner MS spectra and improved peak response reproducibility. This hybrid surface barrier appears to offer significant advantages in the analysis of low-concentration metabolites, potentially facilitating the accurate determination of the elimination phase of the pharmacokinetic (PK) curve and detection of drug metabolites in microdosing or microsampling studies.
Collapse
Affiliation(s)
- Robert S Plumb
- Scientific Operations, Waters Corporation, 34 Maple St, Milford, MA, 01757, USA.
| | - Lee A Gethings
- Scientific Operations, Waters Corporation, Stamford Ave, Wilmslow, Manchester, SK9 4AX, UK
| | - Adam King
- Scientific Operations, Waters Corporation, Stamford Ave, Wilmslow, Manchester, SK9 4AX, UK; Centre for Computational and Systems Medicine, Health Futures Institute, Murdoch University, South Street, Murdoch, WA, 6150, Australia
| | - Lauren G Mullin
- Scientific Operations, Waters Corporation, Stamford Ave, Wilmslow, Manchester, SK9 4AX, UK
| | - Garth Maker
- Centre for Computational and Systems Medicine, Health Futures Institute, Murdoch University, South Street, Murdoch, WA, 6150, Australia
| | - Robert Trengove
- Separations Science and Metabolomics Laboratory, Murdoch University, South Street, Murdoch, WA, 6150, Australia
| | - Ian D Wilson
- Computational & Systems Medicine, Imperial College, Exhibition Rd, London, SW7 2AZ, UK
| |
Collapse
|
23
|
DeLano M, Walter TH, Lauber MA, Gilar M, Jung MC, Nguyen JM, Boissel C, Patel AV, Bates-Harrison A, Wyndham KD. Using Hybrid Organic-Inorganic Surface Technology to Mitigate Analyte Interactions with Metal Surfaces in UHPLC. Anal Chem 2021; 93:5773-5781. [PMID: 33798331 DOI: 10.1021/acs.analchem.0c05203] [Citation(s) in RCA: 36] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Interactions of analytes with metal surfaces in high-performance liquid chromatography (HPLC) instruments and columns have been reported to cause deleterious effects ranging from peak tailing to a complete loss of the analyte signal. These effects are due to the adsorption of certain analytes on the metal oxide layer on the surface of the metal components. We have developed a novel surface modification technology and applied it to the metal components in ultra-HPLC (UHPLC) instruments and columns to mitigate these interactions. A hybrid organic-inorganic surface, based on an ethylene-bridged siloxane chemistry, was developed for use with reversed-phase and hydrophilic interaction chromatography. We have characterized the performance of UHPLC instruments and columns that incorporate this surface technology and compared the results with those obtained using their conventional counterparts. We demonstrate improved performance when using the hybrid surface technology for separations of nucleotides, a phosphopeptide, and an oligonucleotide. The hybrid surface technology was found to result in higher and more consistent analyte peak areas and improved peak shape, particularly when using low analyte mass loads and acidic mobile phases. Reduced abundances of iron adducts in the mass spectrum of a peptide were also observed when using UHPLC systems and columns that incorporate hybrid surface technology. These results suggest that this technology will be particularly beneficial in UHPLC/mass spectrometry investigations of metal-sensitive analytes.
Collapse
Affiliation(s)
- Mathew DeLano
- Waters Corporation, 34 Maple Street, Milford, Massachusetts 01757, United States
| | - Thomas H Walter
- Waters Corporation, 34 Maple Street, Milford, Massachusetts 01757, United States
| | - Matthew A Lauber
- Waters Corporation, 34 Maple Street, Milford, Massachusetts 01757, United States
| | - Martin Gilar
- Waters Corporation, 34 Maple Street, Milford, Massachusetts 01757, United States
| | - Moon Chul Jung
- Waters Corporation, 34 Maple Street, Milford, Massachusetts 01757, United States
| | - Jennifer M Nguyen
- Waters Corporation, 34 Maple Street, Milford, Massachusetts 01757, United States
| | - Cheryl Boissel
- Waters Corporation, 34 Maple Street, Milford, Massachusetts 01757, United States
| | - Amit V Patel
- Waters Corporation, 34 Maple Street, Milford, Massachusetts 01757, United States
| | | | - Kevin D Wyndham
- Waters Corporation, 34 Maple Street, Milford, Massachusetts 01757, United States
| |
Collapse
|
24
|
Willacey CC, Karu N, Harms AC, Hankemeier T. Metabolic profiling of material-limited cell samples by dimethylaminophenacyl bromide derivatization with UPLC-MS/MS analysis. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105445] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
25
|
Azlan NSM, Wee SY, Ismail NAH, Nasir HM, Aris AZ. Organophosphorus Pesticide Multiresidues in Commercialized Asian Rice. ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY 2020; 39:1908-1917. [PMID: 32621623 DOI: 10.1002/etc.4813] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/04/2019] [Revised: 12/15/2019] [Accepted: 07/02/2020] [Indexed: 06/11/2023]
Abstract
The organophosphorus pesticides (OPPs) commonly used in agricultural practices can pose a risk of potential exposure to humans via food consumption. We describe an analytical method for solid-phase extraction coupled with high-performance liquid chromatography-diode array detector (SPE-HPLC-DAD) for the detection of OPPs (quinalphos, diazinon, and chlorpyrifos) in rice grains. The isolation of targeted residues was initiated with double extraction before SPE-HPLC-DAD, crucially reducing matrix interferences and detecting a wide range of multiple residues in rice grains. Coefficients of 0.9968 to 0.9991 showed a strong linearity, with limits of detection and quantification ranging from 0.36 to 0.68 µg/kg and from 1.20 to 2.28 µg/kg, respectively. High recoveries (80.4-110.3%) were observed at 3 spiking levels (50, 100, and 200 µg/kg), indicating good accuracy. The relative standard deviations of all residues (0.19-8.66%) validated the method precision. Sample analysis of 10 rice grain types (n = 30) available in the Asian market revealed that quinalphos, diazinon, and chlorpyrifos at concentrations of 1.08, 1.11, and 1.79 µg/kg, respectively, remained far below the maximum residue limits (0.01-0.5 mg/kg). However, regular monitoring is necessary to confirm that multiresidue occurrence remains below permissible limits while controlling pests. Environ Toxicol Chem 2020;39:1908-1917. © 2020 SETAC.
Collapse
Affiliation(s)
- Nadiah Syafiqah Mohd Azlan
- Department of Environment, Faculty of Forestry and Environment, Universiti Putra Malaysia, Serdang, Selangor, Malaysia
| | - Sze Yee Wee
- Department of Environment, Faculty of Forestry and Environment, Universiti Putra Malaysia, Serdang, Selangor, Malaysia
| | - Nur Afifah Hanun Ismail
- Department of Environment, Faculty of Forestry and Environment, Universiti Putra Malaysia, Serdang, Selangor, Malaysia
| | - Hanisah Mohmad Nasir
- Department of Environment, Faculty of Forestry and Environment, Universiti Putra Malaysia, Serdang, Selangor, Malaysia
| | - Ahmad Zaharin Aris
- Department of Environment, Faculty of Forestry and Environment, Universiti Putra Malaysia, Serdang, Selangor, Malaysia
| |
Collapse
|
26
|
Violi JP, Bishop DP, Padula MP, Steele JR, Rodgers KJ. Considerations for amino acid analysis by liquid chromatography-tandem mass spectrometry: A tutorial review. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.116018] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
27
|
Dufour A, Thiébaut D, Loriau M, Ligiero L, Vial J. Corona charged aerosol detector non-uniform response factors of purified alcohol ethoxylated homologues using liquid chromatography. J Chromatogr A 2020; 1627:461402. [PMID: 32823107 DOI: 10.1016/j.chroma.2020.461402] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Revised: 07/02/2020] [Accepted: 07/11/2020] [Indexed: 10/23/2022]
Abstract
Surfactants are used in various applications: cosmetics, pharmaceuticals, petrochemicals, environmental, etc. Many of these compounds are polydisperse, and because of this intrinsic polydispersity, it is essential to have a universal detector with a uniform response to quantify them in a simple way. Indeed, Charged Aerosol Detector (CAD) was presented as a universal detector with a uniform response. Thus, in the present study, the CAD response, in a High-Performance Liquid Chromatography - CAD configuration (HPLCCAD), was evaluated using purified alcohol ethoxylated surfactants. A semi-preparative liquid chromatography step using a Hydrophilic interaction chromatography (HILIC) bare silica column (150 mm, 4.6 mm, 2.6 µm) was implemented to prepare eleven homologues of BrijC10, a nonionic surfactant. These homologues differed only by the number of ethylene oxide units. BrijC10 homologues were analyzed by HPLCCAD, using a HILIC bare silica column (150 mm, 2.1 mm, 2.6 µm) to determine the HPLCCAD response factors of purified homologues. From the calibration curves (from 100 to 500 mg.kg-1), their response factors were estimated: differences in response factors were observed and a maximum difference in response factors of 3.6 was obtained. Thus, it could be concluded that CAD hyphenated to HILIC separation did not present a uniform response for this homologue's distribution.
Collapse
Affiliation(s)
- Alizée Dufour
- Total S.A. Exploration & Production Lacq Research Center (PERL), 64170 Lacq, France; LSABM, UMR CBI 8231, ESPCI Paris PSL Research University CNRS, 10 rue Vauquelin, 75005 Paris, France.
| | - Didier Thiébaut
- LSABM, UMR CBI 8231, ESPCI Paris PSL Research University CNRS, 10 rue Vauquelin, 75005 Paris, France
| | - Matthieu Loriau
- Total S.A. Exploration & Production Lacq Research Center (PERL), 64170 Lacq, France
| | - Leticia Ligiero
- Total S.A. Exploration & Production Lacq Research Center (PERL), 64170 Lacq, France
| | - Jérôme Vial
- LSABM, UMR CBI 8231, ESPCI Paris PSL Research University CNRS, 10 rue Vauquelin, 75005 Paris, France
| |
Collapse
|
28
|
Miah S, Fukiage S, Begum ZA, Murakami T, Mashio AS, Rahman IMM, Hasegawa H. A technique for the speciation analysis of metal-chelator complexes in aqueous matrices using ultra-performance liquid chromatography-quadrupole/time-of-flight mass spectrometry. J Chromatogr A 2020; 1630:461528. [PMID: 32950813 DOI: 10.1016/j.chroma.2020.461528] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2020] [Revised: 09/02/2020] [Accepted: 09/04/2020] [Indexed: 10/23/2022]
Abstract
Chelators, capable of creating soluble complexes with metals, may disrupt the natural speciation of metals in environmental matrices. Detection of environmental speciation of such complexes has remained challenging as obtaining the precise inherent nature of metal-chelator complexes is difficult by using routine techniques. Herein, we report a rapid and sensitive technique for the speciation analysis of complexes of five metal ions (Ni, Pb, Co, Fe and Ca) with two aminopolycarboxylate chelator variants, namely, EDTA (ethylenediaminetetraacetic acid) and EDDS (ethylenediamine-N,N'-disuccinic acid), including the simultaneous quantification of those complexes. EDTA is characterized as environmentally persistent among the chelators used in the current work whereas EDDS is biodegradable. The speciation analysis was performed using ultra-performance liquid chromatography-quadrupole/time-of-flight mass spectrometry (UPLC-Q-TOF-MS). The separation was achieved by using hydrophilic interaction liquid chromatographic column. The effect of various operating parameters on analytes such as mobile-phase composition, buffer concentrations and pH, sample diluents, sample injection volume, and column temperature on the peak shape and sensitivity were systematically optimized. The dilution was the only requirement for preparing the samples for analysis. The average relative uncertainty was 2.4% with the average precision (as RSD, n= 7) of 3.5%. For the metal-EDTA complexes, LOD range was 3 to 76 nmol L-1 with satisfactory recovery from a simulated mix matrix (recovery: 79-97%) and river water by standard addition (recovery: 82-94%). For metal-EDDS complexes, LOD range was 66 to 293 nmol L-1 with recovery from a simulated mix matrix (recovery: 56-97%) and river water by standard addition (recovery: 61-91%). The proposed method will be applicable in speciation analysis and simultaneous detection of metal-chelator complexes from environmental samples.
Collapse
Affiliation(s)
- Sohag Miah
- Graduate School of Natural Science and Technology, Kanazawa University, Kakuma, Kanazawa 920-1192, Japan; Institute of Forestry and Environmental Sciences, University of Chittagong, Chattogram 4331, Bangladesh.
| | - Shohei Fukiage
- Graduate School of Natural Science and Technology, Kanazawa University, Kakuma, Kanazawa 920-1192, Japan
| | - Zinnat A Begum
- Venture Business Laboratory, Organization of Frontier Science and Innovation, Kanazawa University, Kakuma, Kanazawa 920-1192, Japan
| | - Takaya Murakami
- Institute of Science and Engineering, Kanazawa University, Kakuma, Kanazawa 920-1192, Japan; Forensic Science Laboratory, Ishikawa Prefectural Police Headquarters, Kanazawa, Japan
| | - Asami S Mashio
- Institute of Science and Engineering, Kanazawa University, Kakuma, Kanazawa 920-1192, Japan
| | - Ismail M M Rahman
- Institute of Environmental Radioactivity, Fukushima University, 1 Kanayagawa, Fukushima City, Fukushima 960-1296, Japan.
| | - Hiroshi Hasegawa
- Institute of Science and Engineering, Kanazawa University, Kakuma, Kanazawa 920-1192, Japan.
| |
Collapse
|
29
|
De Pra M, Greco G, Krajewski MP, Martin MM, George E, Bartsch N, Steiner F. Effects of titanium contamination caused by iron-free high-performance liquid chromatography systems on peak shape and retention of drugs with chelating properties. J Chromatogr A 2020; 1611:460619. [DOI: 10.1016/j.chroma.2019.460619] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2019] [Revised: 10/09/2019] [Accepted: 10/12/2019] [Indexed: 02/03/2023]
|
30
|
Heinle L, Patel H, Jenkins G, Ruterbories K. Analytical method considerations regarding carryover for monophosphate prodrugs for in vivo samples by liquid chromatography-tandem mass spectrometry. J Chromatogr A 2019; 1606:460379. [PMID: 31395357 DOI: 10.1016/j.chroma.2019.460379] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2019] [Revised: 07/15/2019] [Accepted: 07/17/2019] [Indexed: 12/21/2022]
Abstract
Three different components that impact carryover in a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method were evaluated to establish baseline conditions for analyzing in vivo samples for twelve monophosphate prodrug compounds and their corresponding parent compounds. The three components were: wash solvent modifier, column shell material (metal vs. metal free), and tubing composition. These components were tested for their impact on system carryover by using rat plasma extracted samples. It was determined that a wash solution containing hexylamine yielded the lowest average carryover of the solutions tested. In addition, metal free columns and PEEK (poly ether ether ketone) tubing yielded the lowest carryover when compared to metal columns, stainless steel tubing and nickel tubing. These conditions were also tested against the parent molecules for each prodrug in the test set, to ensure that changing the conditions for the prodrugs did not impact the ability to analyze the parent, since there is typically a desire to measure both compounds in study samples. Under all conditions, the carryover of the corresponding parent molecule was not adversely impacted in these studies.
Collapse
Affiliation(s)
- Lance Heinle
- Department of Drug Metabolism, Pharmacokinetics and Bioanalysis, AbbVie Inc., North Chicago, IL, 60064, USA.
| | - Hardikkumar Patel
- Department of Drug Metabolism, Pharmacokinetics and Bioanalysis, AbbVie Inc., North Chicago, IL, 60064, USA
| | - Gary Jenkins
- Department of Drug Metabolism, Pharmacokinetics and Bioanalysis, AbbVie Inc., North Chicago, IL, 60064, USA
| | - Kenneth Ruterbories
- Department of Drug Metabolism, Pharmacokinetics and Bioanalysis, AbbVie Inc., North Chicago, IL, 60064, USA
| |
Collapse
|
31
|
Dong M, Qin L, Ma LX, Zhao ZY, Du M, Kunihiko K, Zhu BW. Postmortem nucleotide degradation in turbot mince during chill and partial freezing storage. Food Chem 2019; 311:125900. [PMID: 31780223 DOI: 10.1016/j.foodchem.2019.125900] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2019] [Revised: 11/07/2019] [Accepted: 11/12/2019] [Indexed: 02/08/2023]
Abstract
Nucleotide degradation in fish is an important biochemical change after death, which is closely related to freshness and sensory quality. However, except ATP-relative nucleotides, it remains unclear about changes in other nucleotide metabolites during postmortem stage. In this study, a strategy for the simultaneous quantification of 28 nucleobases, nucleosides, and nucleotides using hydrophilic interaction chromatography coupled with tandem mass spectrometry (HILIC-MS/MS) with positive/negative ion switching was developed. This method showed good linearity, precision, repeatability, and recovery. Furthermore, it was successfully applied to monitor the postmortem nucleotide degradation of turbot mince during chill (4 °C) and partial freezing (-3 °C) storage for 168 h. It was noted that the patterns of the changes in nucleotide metabolites differed considerably depending on the storage temperature. Meanwhile, the different pathway and speed of nucleotide catabolism in turbot mince was summarized based on the quantification data.
Collapse
Affiliation(s)
- Meng Dong
- National Engineering Research Center of Seafood, School of Food Science and Technology, Dalian Polytechnic University, Dalian 116034, China
| | - Lei Qin
- National Engineering Research Center of Seafood, School of Food Science and Technology, Dalian Polytechnic University, Dalian 116034, China.
| | - Li-Xin Ma
- National Engineering Research Center of Seafood, School of Food Science and Technology, Dalian Polytechnic University, Dalian 116034, China
| | - Zi-Yuan Zhao
- National Engineering Research Center of Seafood, School of Food Science and Technology, Dalian Polytechnic University, Dalian 116034, China
| | - Ming Du
- National Engineering Research Center of Seafood, School of Food Science and Technology, Dalian Polytechnic University, Dalian 116034, China
| | - Konno Kunihiko
- National Engineering Research Center of Seafood, School of Food Science and Technology, Dalian Polytechnic University, Dalian 116034, China
| | - Bei-Wei Zhu
- National Engineering Research Center of Seafood, School of Food Science and Technology, Dalian Polytechnic University, Dalian 116034, China
| |
Collapse
|
32
|
Ferré S, González-Ruiz V, Guillarme D, Rudaz S. Analytical strategies for the determination of amino acids: Past, present and future trends. J Chromatogr B Analyt Technol Biomed Life Sci 2019; 1132:121819. [PMID: 31704619 DOI: 10.1016/j.jchromb.2019.121819] [Citation(s) in RCA: 47] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2019] [Revised: 09/25/2019] [Accepted: 09/27/2019] [Indexed: 12/27/2022]
Abstract
This review describes the analytical methods that have been developed over the years to tackle the high polarity and non-chromophoric nature of amino acids (AAs). First, the historical methods are briefly presented, with a strong focus on the use of derivatization reagents to make AAs detectable with spectroscopic techniques (ultraviolet and fluorescence) and/or sufficiently retained in reversed phase liquid chromatography. Then, an overview of the current analytical strategies for achiral separation of AAs is provided, in which mass spectrometry (MS) becomes the most widely used detection mode in combination with innovative liquid chromatography or capillary electrophoresis conditions to detect AAs at very low concentration in complex matrixes. Finally, some future trends of AA analysis are provided in the last section of the review, including the use of supercritical fluid chromatography (SFC), multidimensional liquid chromatography and electrophoretic separations, hyphenation of ion exchange chromatography to mass spectrometry, and use of ion mobility spectrometry mass spectrometry (IM-MS). Various application examples will also be presented throughout the review to highlight the benefits and limitations of these different analytical approaches for AAs determination.
Collapse
Affiliation(s)
- Sabrina Ferré
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland
| | - Víctor González-Ruiz
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland; Swiss Centre for Applied Human Toxicology (SCAHT), Switzerland
| | - Davy Guillarme
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland.
| | - Serge Rudaz
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland; Swiss Centre for Applied Human Toxicology (SCAHT), Switzerland
| |
Collapse
|
33
|
Development and validation of a rapid LC–MS/MS method for determination of methylated nucleosides and nucleobases in urine. J Chromatogr B Analyt Technol Biomed Life Sci 2019; 1128:121775. [DOI: 10.1016/j.jchromb.2019.121775] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2019] [Revised: 08/12/2019] [Accepted: 08/20/2019] [Indexed: 12/11/2022]
|
34
|
Seidl C, Bell DS, Stoll DR. A study of the re-equilibration of hydrophilic interaction columns with a focus on viability for use in two-dimensional liquid chromatography. J Chromatogr A 2019; 1604:460484. [DOI: 10.1016/j.chroma.2019.460484] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2019] [Revised: 08/26/2019] [Accepted: 08/26/2019] [Indexed: 10/26/2022]
|
35
|
Zborníková E, Knejzlík Z, Hauryliuk V, Krásný L, Rejman D. Analysis of nucleotide pools in bacteria using HPLC-MS in HILIC mode. Talanta 2019; 205:120161. [PMID: 31450400 DOI: 10.1016/j.talanta.2019.120161] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2019] [Revised: 07/15/2019] [Accepted: 07/17/2019] [Indexed: 01/25/2023]
Abstract
Nucleotides, nucleosides and their derivatives are present in all cells at varying concentrations that change with the nutritional, and energetic status of the cell. Precise measurement of the concentrations of these molecules is instrumental for understanding their regulatory effects. Such measurement is challenging due to the inherent instability of these molecules and, despite many decades of research, the reported values differ widely. Here, we present a comprehensive and easy-to-use approach for determination of the intracellular concentrations of >25 target molecular species. The approach uses rapid filtration and cold acidic extraction followed by high performance liquid chromatography (HPLC) in the hydrophilic interaction liquid chromatography (HILIC) mode using zwitterionic columns coupled with UV and MS detectors. The method reliably detects and quantifies all the analytes expected to be observed in the bacterial cell and paves the way for future studies correlating their concentrations with biological effects.
Collapse
Affiliation(s)
- Eva Zborníková
- Institute of Organic Chemistry and Biochemistry, Academy of Sciences of the Czech Republic, v.v.i., Flemingovonam. 2, CZ-166 10, Prague 6, Czech Republic; Charles University, Faculty of Science, Department of Analytical Chemistry, Hlavova 8, 128 43, Prague 2, Czech Republic
| | - Zdeněk Knejzlík
- Institute of Organic Chemistry and Biochemistry, Academy of Sciences of the Czech Republic, v.v.i., Flemingovonam. 2, CZ-166 10, Prague 6, Czech Republic
| | - Vasili Hauryliuk
- Department of Molecular Biology, Umeå University, Building 6K, 6L University Hospital Area, SE-901 87, Umeå, Sweden; Laboratory for Molecular Infection Medicine Sweden (MIMS), Umeå University, Building 6K and 6L, University Hospital Area, 90187, Umeå, Sweden; University of Tartu, Institute of Technology, 50411, Tartu, Estonia
| | - Libor Krásný
- Institute of Microbiology, Czech Academy of Sciences v.v.i., Vídeňská 1083, 142 20, Prague 4, Czech Republic
| | - Dominik Rejman
- Institute of Organic Chemistry and Biochemistry, Academy of Sciences of the Czech Republic, v.v.i., Flemingovonam. 2, CZ-166 10, Prague 6, Czech Republic.
| |
Collapse
|
36
|
Hirose T, Keck D, Izumi Y, Bamba T. Comparison of Retention Behavior between Supercritical Fluid Chromatography and Normal-Phase High-Performance Liquid Chromatography with Various Stationary Phases. Molecules 2019; 24:molecules24132425. [PMID: 31269632 PMCID: PMC6650800 DOI: 10.3390/molecules24132425] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2019] [Revised: 06/28/2019] [Accepted: 07/01/2019] [Indexed: 02/06/2023] Open
Abstract
The retention behavior of a wide variety of stationary phases was compared in supercritical fluid chromatography (SFC) and normal-phase high-performance liquid chromatography (NP-HPLC). We also attempted to elucidate the retention behavior in SFC by investigating the selectivity of the different stationary phases. SFC separation conditions with polar stationary phases, such as silica gel (SL) and diol (Diol) phases, operate via adsorptions that include hydrophilic and ionic interactions similar to those in NP-HPLC. Moreover, non-polar stationary phases, such as pentabromophenyl (PBr), pyrenylethyl (PYE), and octadecyl (C18), could be used despite the non-polar mobile phase conditions, because the dispersion and π-π interactions were stronger in SFC than in HPLC. These results reflect the selectivity of the stationary phase and its retention factor, thus providing useful information for the selection of appropriate stationary phases for particular analytes.
Collapse
Affiliation(s)
- Tsunehisa Hirose
- Nacalai Tesque, Inc., Ishibashi 617-0004 17, Kaide-cho, Muko-shi, Kyoto, Japan.
| | - Daniel Keck
- Nacalai Tesque, Inc., Ishibashi 617-0004 17, Kaide-cho, Muko-shi, Kyoto, Japan
| | - Yoshihiro Izumi
- Division of Metabolomics, Medical Institute of Bioregulation, Kyushu University, Maidashi 812-8582 3-1-1, Higashi-ku, Fukuoka, Japan
| | - Takeshi Bamba
- Division of Metabolomics, Medical Institute of Bioregulation, Kyushu University, Maidashi 812-8582 3-1-1, Higashi-ku, Fukuoka, Japan
| |
Collapse
|
37
|
Kartsova LA, Bessonova EA, Somova VD. Hydrophilic Interaction Chromatography. JOURNAL OF ANALYTICAL CHEMISTRY 2019. [DOI: 10.1134/s1061934819050058] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
38
|
Ikegami T. Hydrophilic interaction chromatography for the analysis of biopharmaceutical drugs and therapeutic peptides: A review based on the separation characteristics of the hydrophilic interaction chromatography phases. J Sep Sci 2019; 42:130-213. [DOI: 10.1002/jssc.201801074] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2018] [Revised: 11/17/2018] [Accepted: 11/18/2018] [Indexed: 12/13/2022]
Affiliation(s)
- Tohru Ikegami
- Faculty of Molecular Chemistry and Engineering; Kyoto Institute of Technology; Kyoto Japan
- Institute of Pharmaceutical Sciences; Pharmaceutical (Bio-) Analysis; Eberhard-Karls Universität Tübingen; Tübingen Germany
| |
Collapse
|
39
|
D’Atri V, Fekete S, Clarke A, Veuthey JL, Guillarme D. Recent Advances in Chromatography for Pharmaceutical Analysis. Anal Chem 2018; 91:210-239. [DOI: 10.1021/acs.analchem.8b05026] [Citation(s) in RCA: 55] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Valentina D’Atri
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, CMU-Rue Michel Servet 1, 1211 Geneva 4, Switzerland
| | - Szabolcs Fekete
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, CMU-Rue Michel Servet 1, 1211 Geneva 4, Switzerland
| | - Adrian Clarke
- Novartis Pharma AG, Technical Research and Development, Chemical and Analytical Development (CHAD), Basel, CH4056, Switzerland
| | - Jean-Luc Veuthey
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, CMU-Rue Michel Servet 1, 1211 Geneva 4, Switzerland
| | - Davy Guillarme
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, CMU-Rue Michel Servet 1, 1211 Geneva 4, Switzerland
| |
Collapse
|
40
|
Konya Y, Taniguchi M, Furuno M, Nakano Y, Tanaka N, Fukusaki E. Mechanistic study on the high-selectivity enantioseparation of amino acids using a chiral crown ether-bonded stationary phase and acidic, highly organic mobile phase by liquid chromatography/time-of-flight mass spectrometry. J Chromatogr A 2018; 1578:35-44. [PMID: 30340763 DOI: 10.1016/j.chroma.2018.10.004] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2018] [Revised: 09/26/2018] [Accepted: 10/05/2018] [Indexed: 12/16/2022]
Abstract
The separation mechanism of amino acid enantiomers using a chiral crown ether-bonded stationary phase, CROWNPAK CR-I(+), and acetonitrile (ACN)-rich mobile phases (MPs) was studied. The retention factors of proteinogenic l-amino acids (except proline) formed U-shaped plots against the ACN content in the MP with a sharp increase at a high ACN content, while d-amino acids showed much smaller increases or monotonous decreases in retention within the same range. The use of an acidic, highly organic MP with trifluoroacetic acid (TFA) provided a high enantioselectivity with a short separation time from the contribution of the increased binding of the ammonium group of the analytes to the crown ether functionality of the stationary phase and electrostatic repulsion counteracting the hydrophilic partition mechanism. Optimizing the sample diluent and MP alleviated the peak distortion caused by a moving water band that accompanied the hydrophilic interaction liquid chromatography-like elution conditions. The liquid chromatography/time-of-flight mass spectrometry method with the optimized MP - ACN/ethanol/water/TFA = 80/15/5/0.5 (v/v/v/v) - enabled the determination of eighteen pairs of proteinogenic amino acid enantiomers within 10 min. The conditions also provided the following advantages: (i) fast and highly reproducible separations under isocratic conditions, (ii) high sensitivity and low backpressure using the MP with a high organic content, and (iii) highly reliable peak identification by combining two columns (CR-I(+) and CR-I(-)), reversing the elution orders of the enantiomers.
Collapse
Affiliation(s)
- Yutaka Konya
- Department of Biotechnology, Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Moyu Taniguchi
- Department of Biotechnology, Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Masahiro Furuno
- Department of Biotechnology, Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Yosuke Nakano
- Department of Biotechnology, Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Nobuo Tanaka
- Department of Biotechnology, Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka, 565-0871, Japan.
| | - Eiichiro Fukusaki
- Department of Biotechnology, Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka, 565-0871, Japan.
| |
Collapse
|
41
|
Spalding JL, Naser FJ, Mahieu NG, Johnson SL, Patti GJ. Trace Phosphate Improves ZIC-pHILIC Peak Shape, Sensitivity, and Coverage for Untargeted Metabolomics. J Proteome Res 2018; 17:3537-3546. [PMID: 30160483 DOI: 10.1021/acs.jproteome.8b00487] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Existing hydrophilic interaction liquid chromatography (HILIC) methods, considered individually, each exhibit poor chromatographic performance for a substantial fraction of polar metabolites. In addition to limiting metabolome coverage, such deficiencies also complicate automated data processing. Here we show that some of these analytical challenges can be addressed for the ZIC-pHILIC, a zwitterionic stationary phase commonly used in metabolomics, with the addition of trace levels of phosphate. Specifically, micromolar phosphate extended metabolome coverage by hundreds of credentialed features, improved peak shapes, and reduced peak-detection errors during informatic processing. Although the addition of high levels of phosphate (millimolar) as a HILIC mobile phase buffer has been explored previously, such concentrations interfere with mass spectrometric (MS) detection. We show that using phosphate as a trace additive at micromolar concentrations improves analysis by electrospray MS, increasing signal for a diverse set of polar standards. Given the small amount of phosphate needed, comparable chromatographic improvements were also achieved by direct addition of phosphate to the sample during reconstitution. Our results suggest that defects in ZIC-pHILIC performance are predominantly driven by electrostatic interactions, which can be modulated by phosphate. These findings constitute both a methodological improvement for untargeted metabolomics and an advance in our understanding of the mechanisms limiting HILIC coverage.
Collapse
Affiliation(s)
- Jonathan L Spalding
- Department of Chemistry , Washington University in St. Louis , St. Louis , MO 63130 , United States.,Department of Genetics , Washington University in St. Louis , St. Louis , MO 63110 , United States.,Department of Medicine , Washington University in St. Louis , St. Louis , MO 63110 , United States
| | - Fuad J Naser
- Department of Chemistry , Washington University in St. Louis , St. Louis , MO 63130 , United States
| | - Nathaniel G Mahieu
- Department of Chemistry , Washington University in St. Louis , St. Louis , MO 63130 , United States
| | - Stephen L Johnson
- Department of Genetics , Washington University in St. Louis , St. Louis , MO 63110 , United States
| | - Gary J Patti
- Department of Chemistry , Washington University in St. Louis , St. Louis , MO 63130 , United States.,Department of Medicine , Washington University in St. Louis , St. Louis , MO 63110 , United States
| |
Collapse
|
42
|
Rounova O, Demin P, Korotkov M, Malkova V, Ustinnikova O. Development of a hydrophilic interaction high-performance liquid chromatography method for the determination of glycine in formulations of therapeutic immunoglobulins. Anal Bioanal Chem 2018; 410:6935-6942. [DOI: 10.1007/s00216-018-1297-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2018] [Revised: 07/24/2018] [Accepted: 07/26/2018] [Indexed: 10/28/2022]
|
43
|
Hsiao JJ, Potter OG, Chu TW, Yin H. Improved LC/MS Methods for the Analysis of Metal-Sensitive Analytes Using Medronic Acid as a Mobile Phase Additive. Anal Chem 2018; 90:9457-9464. [PMID: 29976062 DOI: 10.1021/acs.analchem.8b02100] [Citation(s) in RCA: 53] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Phosphorylated compounds and organic acids with multiple carboxylate groups are commonly observed to have poor peak shapes and signal in LC/MS experiments. The poor peak shape is caused by the presence of trace metals, particularly iron, contributed from a variety of sources within the chromatographic system. To ameliorate this problem, different solvent additives were investigated to reduce the amount of metal in the flow path to achieve better analytical performance for these metal-sensitive compounds. Here, we introduce the use of a solvent additive that can significantly improve the peak shapes and signal of metal-sensitive metabolites for LC/MS analysis. Moreover, the additive is shown to be amenable for other metal-sensitive applications, such as the analysis of phosphopeptides and polar phosphorylated pesticides, where the instruments could be used in either positive or negative analysis mode.
Collapse
Affiliation(s)
- Jordy J Hsiao
- Agilent Technologies, Santa Clara , California 95051 , United States
| | - Oscar G Potter
- Agilent Technologies, Santa Clara , California 95051 , United States
| | - Te-Wei Chu
- Agilent Technologies, Santa Clara , California 95051 , United States
| | - Hongfeng Yin
- Agilent Technologies, Santa Clara , California 95051 , United States
| |
Collapse
|
44
|
Arase S, Kimura S, Ikegami T. Method optimization of hydrophilic interaction chromatography separation of nucleotides using design of experiment approaches I: Comparison of several zwitterionic columns. J Pharm Biomed Anal 2018; 158:307-316. [PMID: 29909320 DOI: 10.1016/j.jpba.2018.05.014] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2018] [Revised: 04/27/2018] [Accepted: 05/11/2018] [Indexed: 10/16/2022]
Abstract
A systematic method in hydrophilic interaction chromatography (HILIC) was developed for the separation of four monophosphate nucleotides using design of experiment (DOE) approaches. Three HPLC parameters, the buffer concentration (ammonium acetate concentration), gradient time, and temperature, were evaluated within the quality design framework, and the effects on chromatographic parameters were investigated. Four zwitterionic columns (ZIC-HILIC, ZIC-cHILIC, NUCLEODUR HILIC, and PC HILIC) were used to separate four nucleotides, and the HPLC conditions for each column were successfully optimized, although PC HILIC did not give peaks that were suitable for optimization. In addition, it was proved that optimized HPLC conditions differed from column to column even when the same types of zwitterionic sulfobetaine-functionalized columns were applied. This tendency was explained by differences in the separation characteristics of each column, the thickness of the water-enriched layer on the surface of the silica supports, and the pH. DOE for development of the HPLC method provides an effective explanation of the interactions among the variable parameters, especially in HILIC mode. Finally, a robust analytical method could be established by setting the optimum parameters. Among the employed columns, ZIC-cHILIC provided the widest range of suitable analytical conditions. NUCLEODUR HILIC was difficult to build a robust analytical method since the elution order of cytidine monophosphate and guanosine monophosphate was reversed.
Collapse
Affiliation(s)
- Shuntaro Arase
- Eisai Co., Ltd., Formulation Research, Pharmaceutical Science & Technology Core Function Unit, Medicine Development Center, Kagamigahara, Gifu, 501-6195, Japan; Faculty of Molecular Chemistry and Engineering, Kyoto Institute of Technology, Matsugasaki, Sakyo-ku, Kyoto, 606-8585, Japan
| | - Susumu Kimura
- Eisai Co., Ltd., Formulation Research, Pharmaceutical Science & Technology Core Function Unit, Medicine Development Center, Kagamigahara, Gifu, 501-6195, Japan
| | - Tohru Ikegami
- Faculty of Molecular Chemistry and Engineering, Kyoto Institute of Technology, Matsugasaki, Sakyo-ku, Kyoto, 606-8585, Japan.
| |
Collapse
|
45
|
Boulard L, Dierkes G, Ternes T. Utilization of large volume zwitterionic hydrophilic interaction liquid chromatography for the analysis of polar pharmaceuticals in aqueous environmental samples: Benefits and limitations. J Chromatogr A 2018; 1535:27-43. [DOI: 10.1016/j.chroma.2017.12.023] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2017] [Revised: 11/21/2017] [Accepted: 12/08/2017] [Indexed: 01/31/2023]
|
46
|
Desfontaine V, Goyon A, Veuthey JL, Charve J, Guillarme D. Development of a LC-MS/MS method for the determination of isomeric glutamyl peptides in food ingredients. J Sep Sci 2017; 41:847-855. [PMID: 29193742 DOI: 10.1002/jssc.201701182] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2017] [Revised: 11/14/2017] [Accepted: 11/15/2017] [Indexed: 11/12/2022]
Abstract
A liquid chromatography with tandem mass spectrometry method was developed for the determination of 27 glutamyl di- and tripeptides in food ingredients. Such compounds are of importance for the food industry, as they can modulate the perception of basic tastes (sweet, salty, and umami). Due to their high polarity, the hydrophilic interaction chromatography mode was selected to have sufficient retention on the column and the best separation was obtained on an amide hybrid silica stationary phase packed with 1.7 μm particles. Thorough optimization of the mobile phase was performed as the start-composition had to be free of ammonium to avoid on-column cis-trans isomerization of the first eluting proline dipeptide. A baseline separation was achieved for all α and γ isomers whereas only a partial resolution was obtained for γ-Glu-Leu and γ-Glu-Ile, for which only the position of a methyl group differs. A fast sample preparation, based on successive dilutions, was performed before injection into the liquid chromatography with tandem mass spectrometry system. The developed method was then applied for the semi-quantification of glutamyl di- and tri-peptides in four different food ingredients. The methodology will further support the optimization of production processes to select the conditions for which the peptide concentrations would be the highest.
Collapse
Affiliation(s)
- Vincent Desfontaine
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Lausanne, Switzerland
| | - Alexandre Goyon
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Lausanne, Switzerland
| | - Jean-Luc Veuthey
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Lausanne, Switzerland
| | | | - Davy Guillarme
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Lausanne, Switzerland
| |
Collapse
|
47
|
Kertys M, Urbanova A, Mokry J. Quantification of Theophylline in Guinea Pig Plasma by LC-MS/MS Using Hydrophilic Interaction Liquid Chromatography Stationary Phase: Method Development, Validation, and Application in Study. ACTA MEDICA MARTINIANA 2017. [DOI: 10.1515/acm-2017-0012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Abstract
Theophylline has been used in the treatment of bronchial asthma and chronic obstructive pulmonary disease (COPD) for over 70 years. In order to maximize the effectiveness and safety of theophylline therapy it is important to individualize the dosage of the drug. In our study we focused on determination of theophylline concentrations in guinea pig plasma. A rapid, specific, and reliable LC-MS/MS-based method was developed and validated according to European Medicine Agency (EMA) guidelines. A hydrophilic interaction liquid chromatography (HILIC) separation mode for reduction time of sample preparation was used. The analysed sample was quantified in a positive ionization mode. Multiple reaction monitoring (MRM) using transition m/z 181.06→124.06 and m/z 187.17→127.06 was performed to quantify theophylline with deuterated internal standard ([2H6]-theophylline), respectively. Modification of collision energies was performed in parallel with chromatographic separation to further eliminate interference from the matrix. The method was validated for a range of 0.5 to 30 μg/mL of plasma sample. The intra-day and inter-day precision and accuracy of the quality control samples at low, me dium, and high concentration levels exhibited relative standard deviations (RSD) of less than 10 %. The method was successfully applied for the quantitation of theophylline in guinea pig plasma for better understanding its effects in a model of ovalbumin-induced allergic inflammation.
Collapse
Affiliation(s)
- M Kertys
- Department of Pharmacology, Jessenius Faculty of Medicine in Martin , Comenius University in Bratislava , Slovakia
- Biomedical Center Martin, Jessenius Faculty of Medicine in Martin , Comenius University in Bratislava , Slovakia
| | - A Urbanova
- Biomedical Center Martin, Jessenius Faculty of Medicine in Martin , Comenius University in Bratislava , Slovakia
- Department of Pharmacology, Jessenius Faculty of Medicine in Martin , Comenius University in Bratislava , Slovakia
| | - J Mokry
- Department of Pharmacology, Jessenius Faculty of Medicine in Martin , Comenius University in Bratislava , Slovakia
- Biomedical Center Martin, Jessenius Faculty of Medicine in Martin , Comenius University in Bratislava , Slovakia
| |
Collapse
|
48
|
Witkowski B, Duchnowicz A, Ganeczko M, Laudy A, Gierczak T, Biesaga M. Identification of proteins, drying oils, waxes and resins in the works of art micro-samples by chromatographic and mass spectrometric techniques. J Sep Sci 2017; 41:630-638. [PMID: 29150927 DOI: 10.1002/jssc.201700937] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2017] [Revised: 10/31/2017] [Accepted: 11/05/2017] [Indexed: 11/06/2022]
Abstract
Simplified method for simultaneous identification of proteins, drying oils, waxes, and resins in the works-of-art samples was developed. Liquid chromatography with mass spectrometry and gas chromatography with mass spectrometry were used to identify natural materials most frequently encountered in historical paintings. Protein binders were extracted with ammonia and purified using miniaturized solid-phase microextraction (Omix tips) to efficiently suppress matrix interferences. Zwitterionic stationary phase was used for separation of 16 underivatized amino acids analysis with hydrophilic interaction liquid chromatography that was subsequently quantified with liquid chromatography with mass spectrometry. Gas chromatography with mass spectrometry was used to analyze drying oils, waxes, and resins after one-step saponification/transmethylation with (m-trifluoromethylphenyl)trimethylammonium hydroxide (Meth-Prep II). While the drawback of this reagent is low reactivity towards hydroxyl groups, sample pretreatment was much simpler as compared to the other methods. Fatty acids derivatization with the Meth-Prep II reagent was compared with their silylation using N,O-bis(trimethylsilyl) trifluoroacetamide/trimethylchlorosilane mixture. It was concluded that fatty acids analysis as their methyl esters instead of trimethylsilyl esters had a minor impact on the method sensitivity. The developed method was used to analyze samples from 16th and 17th century historical paintings.
Collapse
Affiliation(s)
| | - Anna Duchnowicz
- Faculty of Chemistry,al. Żwirki i Wigury, University of Warsaw, Warsaw, Poland
| | - Monika Ganeczko
- Faculty of Chemistry,al. Żwirki i Wigury, University of Warsaw, Warsaw, Poland
| | - Agnieszka Laudy
- Museum of King Jan III's Palace at Wilanów, al., Stanisława Kostki Potockiego, Warsaw, Poland
| | - Tomasz Gierczak
- Faculty of Chemistry,al. Żwirki i Wigury, University of Warsaw, Warsaw, Poland
| | - Magdalena Biesaga
- Faculty of Chemistry,al. Żwirki i Wigury, University of Warsaw, Warsaw, Poland
| |
Collapse
|
49
|
Bobály B, D’Atri V, Beck A, Guillarme D, Fekete S. Analysis of recombinant monoclonal antibodies in hydrophilic interaction chromatography: A generic method development approach. J Pharm Biomed Anal 2017. [DOI: 10.1016/j.jpba.2017.06.016] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
50
|
Rinaldi F, Tengattini S, Calleri E, Bavaro T, Piubelli L, Pollegioni L, Massolini G, Temporini C. Application of a rapid HILIC-UV method for synthesis optimization and stability studies of immunogenic neo -glycoconjugates. J Pharm Biomed Anal 2017; 144:252-262. [DOI: 10.1016/j.jpba.2017.03.052] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2016] [Revised: 03/01/2017] [Accepted: 03/26/2017] [Indexed: 11/25/2022]
|