1
|
Plumb RS, Gethings LA, Isaac G, Munjoma NC, Wilson ID. Detection of pharmacolipidodynamic effects following the intravenous and oral administration of gefitinib to C57Bl/6JRj mice by rapid UHPLC-MS analysis of plasma. Sci Rep 2024; 14:17061. [PMID: 39048625 PMCID: PMC11269747 DOI: 10.1038/s41598-024-66764-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2023] [Accepted: 07/03/2024] [Indexed: 07/27/2024] Open
Abstract
Omics-based biomarker technologies, including metabolic profiling (metabolomics/metabonomics) and lipidomics, are making a significant impact on disease understanding, drug development, and translational research. A wide range of patho-physiological processes involve lipids and monitoring changes in lipid abundance can give valuable insights into mechanisms of drug action, off target pharmacology and toxicity. Here we report changes, detected by untargeted LC-MS, in the plasma lipid profiles of male C57Bl/6JRj mice following the PO and IV administration of the epidermal growth factor receptor (EGFR) inhibitor gefitinib. Statistical analysis of the data obtained for both the IV and PO samples showed time-related changes in the amounts of lipids from several different classes. The largest effects were associated with a rapid onset of these changes following gefitinib administration followed by a gradual return by 24 h post dose to the type of lipid profile seen in predose samples. Investigation of the lipids responsible for the variance observed in the data showed that the PI, PC, LPC, PE and TG were subject to the largest disruption with both transient increases and decreases in relative amounts seen in response to administration of the drug. The pattern of the changes in the relative abundances of those lipids subject to variation appeared to be correlated to the pharmacokinetics of gefitinib (and its major metabolites). These observations support the concept of a distinct pharmacolipidodynamic relationship between drug exposure and plasma lipid abundance.
Collapse
Affiliation(s)
| | | | - Giorgis Isaac
- Program in Molecular Medicine, University of Massachusetts, Chan Medical School, 373 Plantation Street, Worcester, MA, 01605, USA
| | | | - Ian D Wilson
- Computational & Systems Medicine, Department of Metabolism, Digestion and Reproduction, Imperial College, Burlington Danes Building, Du Cane Road, London, W12 0NN, UK.
| |
Collapse
|
2
|
Enhanced chromatographic efficiency obtained with vacuum jacketed columns facilitates the rapid UHPLC/MS/MS-based analysis of fasiglifam in rat plasma. Talanta 2023; 254:124089. [PMID: 36459869 DOI: 10.1016/j.talanta.2022.124089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Revised: 11/03/2022] [Accepted: 11/05/2022] [Indexed: 11/15/2022]
Abstract
The use of vacuum jacketed LC columns (VJC) to minimize on- and post-column band broadening to maximize chromatographic performance has been evaluated as a potential route to improved high throughput (HT) analysis. Here the use of the "VJC" approach has been applied to the HT bioanalysis of the antidiabetic GPR40 agonist drug fasiglifam in rat plasma samples obtained following a 5 mg/kg IV dose. The data obtained from a 1 minute VJC/MS-based analysis showed significant improvements compared to that from a conventional 2 minute UHPLC method for the drug. Notably, using VJC/MS with the rapid 1 min analysis provided a ca. 50% reduction in peak width coupled with a 2-5 fold higher peak response whilst doubling analytical throughput when compared to a conventional UHPLC/MS method. In addition, the increased resolution provided by the VJC system also improved the separation of fasiglifam from common matrix interferences such as co-extracted phospholipids thereby reducing the potential for matrix effects. The concatenation of these improvements suggests that the VJC approach may indeed provide a pathway to more sensitive, robust and high throughput drug bioanalysis, with particular advantages for drug discovery applications.
Collapse
|
3
|
Plumb RS, Gethings LA, Rainville PD, Isaac G, Trengove R, King AM, Wilson ID. Advances in high throughput LC/MS based metabolomics: A review. Trends Analyt Chem 2023. [DOI: 10.1016/j.trac.2023.116954] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
4
|
Gritti FG, Meyyappan S, Leveille WP, Hill J. Improved Performance of UHPLC–MS Hyphenated Systems. LCGC NORTH AMERICA 2022. [DOI: 10.56530/lcgc.na.im3069q9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
Abstract
An ultrahigh-pressure liquid chromatography–mass spectrometry (UHPLC–MS) research prototype instrument was built to improve the resolution power and the usability of conventional LC–MS hyphenated instruments for routine analyses in pharmaceutical applications. The improved characteristics of this UHPLC–MS system include: 1) the dramatic reduction of post-column sample dispersion; 2) the adoption of vacuum jacketed columns (VJC) for the reduction of undesirable radial temperature gradients across the column diameter; and 3) the presence of a column outlet end nut heater to refocus the distorted peaks prior to analyte ionization. The benefits of each of these added features are analyzed with a rigorous approach from a peak broadening perspective. A 2x improvement in peak capacities recorded with this prototype UHPLC–MS system compared to a standard system (Acquity UHPLC I-class/Xevo TQ-S) is illustrated for the gradient separation of seven small pharmaceutical compounds using a 2.1 mm x 100 mm column packed with sub-2-μm core-shell particles (1.6 μm Acquity UHPLC Cortecs C18 column).
Collapse
|
5
|
Plumb RS, Isaac G, Rainville PD, Hill J, Gethings LA, Johnson KA, Lauterbach J, Wilson ID. High Throughput UHPLC-MS-Based Lipidomics Using Vacuum Jacketed Columns. J Proteome Res 2021; 21:691-701. [PMID: 34968064 DOI: 10.1021/acs.jproteome.1c00836] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Reversed-phase UHPLC-MS is extensively employed for both the profiling of biological fluids and tissues to characterize lipid dysregulation in disease and toxicological studies. With conventional LC-MS systems the chromatographic performance and throughput are limited due to dispersion from the fluidic connections as well as radial and longitudinal thermal gradients in the LC column. In this study vacuum jacketed columns (VJC), positioned at the source of the mass spectrometer, were applied to the lipidomic analysis of plasma extracts. Compared to conventional UHPLC, the VJC-based methods offered greater resolution, faster analysis, and improved peak intensity. For a 5 min VJC analysis, the peak capacity increased by 66%, peak tailing reduced by up to 34%, and the number of lipids detected increased by 30% compared to conventional UHPLC. The narrower peaks, and thus increased resolution, compared to the conventional system resulted in a 2-fold increase in peak intensity as well a significant improvement in MS and MS/MS spectral quality resulting in a 22% increase in the number of lipids identified. When applied to mouse plasma samples, reproducibility of the lipid intensities in the pooled QC ranged from 1.8-12%, with no related drift in tR observed.
Collapse
Affiliation(s)
- Robert S Plumb
- Scientific Operations, Waters Corporation, IMMERSE, Cambridge, Massachusetts 02142, United States
| | - Giorgis Isaac
- Scientific Operations, Waters Corporation, IMMERSE, Cambridge, Massachusetts 02142, United States
| | - Paul D Rainville
- Scientific Operations, Waters Corporation, IMMERSE, Cambridge, Massachusetts 02142, United States
| | - Jason Hill
- Global Research, Waters Corporation, IMMERSE, Cambridge, Massachusetts 02142, United States
| | - Lee A Gethings
- Scientific Operations, Waters Corporation, Stamford Avenue, Wilmslow, SK9 4AX, U.K
| | - Kelly A Johnson
- Global Research, Waters Corporation, IMMERSE, Cambridge, Massachusetts 02142, United States
| | - Joshua Lauterbach
- Department of Chemistry, University of Massachusetts Amherst, Amherst, Massachusetts 01003, United States
| | - Ian D Wilson
- Computational & Systems Medicine, Department of Metabolism, Digestion and Reproduction, Imperial College, Exhibition Road, London, SW7 2AZ, U.K
| |
Collapse
|
6
|
Moussa A, Deridder S, Broeckhoven K, Desmet G. Detailed computational fluid dynamics study of the parameters contributing to the viscous heating band broadening in liquid chromatography at pressures up to 2500 bar in 2.1 mm columns. J Chromatogr A 2021; 1661:462683. [PMID: 34883357 DOI: 10.1016/j.chroma.2021.462683] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 11/10/2021] [Accepted: 11/11/2021] [Indexed: 10/19/2022]
Abstract
Over the past years viscous heating band broadening occurring in high pressure liquid chromatography has been studied extensively. In the present numerical study, we investigate the fine details of this band broadening contribution under extreme high-pressure conditions (2500 bar). To analyze the results, we first show that viscous heating leads to two clearly distinguishable band broadening effects, one originating from the radial differences in the species migration velocity and the other from the axial variations. It was found that the radial contribution is independent of the intrinsic band broadening of the bed (i.e. band broadening in absence of viscous heating) while it strongly depends on the radial dispersion coefficient and the retention enthalpy of the analytes. On the other hand, the axial contribution is strongly dependent on the bed intrinsic band broadening and it is found to be 4 to 5 times lower than the radial contribution. We also show the strong effect of the endfittings on the temperature gradients inside the column thus on the resulting viscous heating band broadening.
Collapse
Affiliation(s)
- Ali Moussa
- Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussel, Belgium
| | - Sander Deridder
- KU Leuven, Department of Chemical Engineering, Process and Environmental Technology Lab, J. De Nayerlaan 5, 2860 Sint-Katelijne-Waver, Belgium
| | - Ken Broeckhoven
- Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussel, Belgium
| | - Gert Desmet
- Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussel, Belgium.
| |
Collapse
|
7
|
Computational fluid dynamics study of potential solutions to alleviate viscous heating band broadening in 2.1 millimeter liquid chromatography columns. J Chromatogr A 2021; 1654:462452. [PMID: 34392122 DOI: 10.1016/j.chroma.2021.462452] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2021] [Revised: 08/03/2021] [Accepted: 08/04/2021] [Indexed: 01/19/2023]
Abstract
We report on a numerical simulation study of a number of potential column technology solutions to minimize the plate height contribution (Hvh) originating from the use of ultra-high pressures and their concomitant viscous heating effect. Looking as far as possible into the future of UHPLC, all main results are obtained for the case of a 2500 bar pressure gradient. However, to generalize the result, a correlation is given that can be used to interpolate the results to lower pressures with some 10% accuracy. For the considered case of a 2.1mm column, a liquid flow rate of 0.45 ml/min, an analyte with retention factor k(25°C)=3 and a retention enthalpy chosen such that ΔHR/R= -1000 K, it is found that, in order to keep the global plate height as measured at the column outlet (Hvh,glob,out) below 1 μm, the bed conductivity would need to be raised to λbed=2.4 W/m•K, i.e., 4 times higher than a typical packed bed of fully-porous or core-shell silica particles. An equivalent effect on the band broadening could be obtained if it would be possible to replace the steel column wall with a low conductivity material. In this case, a wall conductivity of 0.25 W/m•K, i.e., 64 times smaller than the conductivity of steel, would be needed to keep Hvh,glob,out below 1 μm. Results are also interpreted based on contour plots of the axial and radial velocity variation of a retained analyte.
Collapse
|
8
|
Plumb RS, McDonald T, Rainville PD, Hill J, Gethings LA, Johnson KA, Wilson ID. High-Throughput UHPLC/MS/MS-Based Metabolic Profiling Using a Vacuum Jacketed Column. Anal Chem 2021; 93:10644-10652. [PMID: 34279080 DOI: 10.1021/acs.analchem.1c01982] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
In UHPLC, frictional heating from the eluent flowing through the column at pressures of ca. 10-15 Kpsi causes radial diffusion via temperature differences between the center of the column and its walls. Longitudinal dispersion also occurs due to temperature gradients between the inlet and outlet. These effects cause band broadening but can be mitigated via a combination of vacuum jacketed stainless steel tubing, reduced column end nut mass, and a constant temperature in the column from heating the inlet fitting. Here, vacuum jacketed column (VJC) technology, employing a novel column housing located on the source of the mass spectrometer and minimized tubing from the column outlet to the electrospray probe, was applied to profiling metabolites in urine. For a 75 s reversed-phase gradient separation, the average peak widths for endogenous compounds in urine were 1.2 and 0.6 s for conventional LC/MS and VJC systems, respectively. The peak tailing factor was reduced from 1.25 to 1.13 when using the VJC system compared to conventional UHPLC, and the peak capacity increased from 65 to 120, with a 25% increase in features detected in urine. The increased resolving power of the VJC system reduced co-elution, simplifying MS and MS/MS spectra, providing a more confident metabolite identification. The increased LC performance also gave more intense MS peaks, with a 10-120% increase in response, improving the quality of the MS data and detection limits. Reducing the LC gradient duration to 37 s gave peak widths of ca. 0.4 s and a peak capacity of 84.
Collapse
Affiliation(s)
- Robert S Plumb
- Scientific Operations, Waters Corporation, IMMERSE, Cambridge, Massachusetts 02142, United States
| | - Thomas McDonald
- Global Research, Waters Corporation, IMMERSE, Cambridge, Massachusetts 02142, United States
| | - Paul D Rainville
- Scientific Operations, Waters Corporation, IMMERSE, Cambridge, Massachusetts 02142, United States
| | - Jason Hill
- Global Research, Waters Corporation, IMMERSE, Cambridge, Massachusetts 02142, United States
| | - Lee A Gethings
- Scientific Operations, Waters Corporation, Stamford Ave, Wilmslow SK9 4AX, U.K
| | - Kelly A Johnson
- Global Research, Waters Corporation, IMMERSE, Cambridge, Massachusetts 02142, United States
| | - Ian D Wilson
- Computational & Systems Medicine, Imperial College, Exhibition Rd, London SW7 2AZ, U.K
| |
Collapse
|
9
|
Werres T, Schmidt TC, Teutenberg T. The influence of injection volume on efficiency of microbore liquid chromatography columns for gradient and isocratic elution. J Chromatogr A 2021; 1641:461965. [PMID: 33611125 DOI: 10.1016/j.chroma.2021.461965] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2020] [Revised: 01/28/2021] [Accepted: 01/31/2021] [Indexed: 01/15/2023]
Abstract
The injection volume and the associated column volume overload is one of the most common issues in miniaturized chromatography. The injection volume should not exceed 10% of the effective column volume. A further reduction of the injection volume leads to an increase in chromatographic efficiency. However, the signal intensity must be above a certain threshold to generate a chromatographic peak that can be detected. Therefore, the injection volume has to be optimized to reach the ideal balance between chromatographic efficiency and sensitivity. This study examined the general influence of the injection volume for both isocratic and gradient elution, depending on the retention factor and peak standard deviation. For this purpose, substances of different polarity were selected to represent a broad elution spectrum. Besides the model analyte naphthalene, these were mainly pharmaceuticals. For all measurements a microbore column with an ID of 300 µm and packed with 1.9 μm fully porous particles was used. For isocratic elution, the injection volume was varied between 4 and 16% of the effective column volume. The retention factors were adjusted between 2 and 10. For gradient elution, the injection volume was varied between 4 and 160% of the effective column volume. The observed effects were further investigated using the gradient kinetic plot theory. In isocratic elution, a loss in plate height up to 50% was observed for components that elute near the void time. A significant reduction of the chromatographic efficiency was noticed up to a retention factor of 4. In gradient elution, a reduction in peak capacity could only be observed if the injection volume exceeded 40% of the effective column volume. For some substances, only a slight loss in peak capacity was noticed even with a volume overload of 160%.
Collapse
Affiliation(s)
- Tobias Werres
- Institut für Energie- und Umwelttechnik e. V., IUTA (Institute of Energy and Environmental Technology), Bliersheimer Str. 58-60, 47229 Duisburg, Germany; Instrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstr. 5, 45141, Essen, Germany
| | - Torsten C Schmidt
- Instrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstr. 5, 45141, Essen, Germany
| | - Thorsten Teutenberg
- Institut für Energie- und Umwelttechnik e. V., IUTA (Institute of Energy and Environmental Technology), Bliersheimer Str. 58-60, 47229 Duisburg, Germany.
| |
Collapse
|
10
|
Broeckhoven K, Desmet G. Methods to determine the kinetic performance limit of contemporary chromatographic techniques. J Sep Sci 2020; 44:323-339. [PMID: 32902146 DOI: 10.1002/jssc.202000779] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Revised: 08/24/2020] [Accepted: 08/31/2020] [Indexed: 12/28/2022]
Abstract
By combining separation efficiency data as a function of flow rate with the column permeability, the kinetic plot method allows to determine the limits of separation power (time vs. efficiency) of different chromatographic techniques and methods. The technique can be applied for all different types of chromatography (liquid, gas, or supercritical fluid), for different types of column morphologies (packed beds, monoliths, open tubular, micromachined columns), for pressure and electro-driven separations and in both isocratic and gradient elution mode. The present contribution gives an overview of the methods and calculations required to correctly determine these kinetic performance limits and their underlying limitations.
Collapse
Affiliation(s)
- Ken Broeckhoven
- Department of Chemical Engineering, Vrije Universiteit Brussel, Brussels, Belgium
| | - Gert Desmet
- Department of Chemical Engineering, Vrije Universiteit Brussel, Brussels, Belgium
| |
Collapse
|
11
|
Broeckhoven K, Desmet G. Advances and Challenges in Extremely High-Pressure Liquid Chromatography in Current and Future Analytical Scale Column Formats. Anal Chem 2019; 92:554-560. [DOI: 10.1021/acs.analchem.9b04278] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Ken Broeckhoven
- Vrije Universiteit Brussel, Department of Chemical Engineering (CHIS), Faculty of Engineering, Pleinlaan 2, 1050 Brussels, Belgium
| | - Gert Desmet
- Vrije Universiteit Brussel, Department of Chemical Engineering (CHIS), Faculty of Engineering, Pleinlaan 2, 1050 Brussels, Belgium
| |
Collapse
|
12
|
Kaplitz AS, Kresge GA, Selover B, Horvat L, Franklin EG, Godinho JM, Grinias KM, Foster SW, Davis JJ, Grinias JP. High-Throughput and Ultrafast Liquid Chromatography. Anal Chem 2019; 92:67-84. [DOI: 10.1021/acs.analchem.9b04713] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Alexander S. Kaplitz
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| | - Glenn A. Kresge
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| | - Benjamin Selover
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| | - Leah Horvat
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| | | | - Justin M. Godinho
- Advanced Materials Technology, Inc., Wilmington, Delaware 19810, United States
| | - Kaitlin M. Grinias
- Analytical Platforms & Platform Modernization, GlaxoSmithKline, Upper Providence, Collegeville, Pennsylvania 19426, United States
| | - Samuel W. Foster
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| | - Joshua J. Davis
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| | - James P. Grinias
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States
| |
Collapse
|
13
|
Ahmad AG, Qamar S, Seidel-Morgenstern A. Linearized non-equilibrium and non-isothermal two-dimensional model of liquid chromatography for studying thermal effects in cylindrical columns. J LIQ CHROMATOGR R T 2019. [DOI: 10.1080/10826076.2019.1625370] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Affiliation(s)
- Abdulaziz Garba Ahmad
- Department of Mathematics, COMSATS University Islamabad, Islamabad, Pakistan
- Department of Mathematics Programme, National Mathematical Centre Abuja, Abuja, Nigeria
| | - Shamsul Qamar
- Department of Mathematics, COMSATS University Islamabad, Islamabad, Pakistan
- Max Planck Institute for Dynamics of Complex Technical Systems, Magdeburg, Germany
| | | |
Collapse
|
14
|
Rehman JU, Muneer A, Abbasi JN, Qamar S, Seidel-Morgenstern A. Study of Thermal Effects in Two-Component Nonisothermal Liquid Chromatography Considering Thermally Insulated Columns. Ind Eng Chem Res 2018. [DOI: 10.1021/acs.iecr.8b02990] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Jamil Ur Rehman
- Department of Mathematics, COMSATS University Islamabad, Islamabad 45550, Pakistan
| | - Adeel Muneer
- Department of Mathematics, COMSATS University Islamabad, Islamabad 45550, Pakistan
| | - Javeria N. Abbasi
- Department of Mathematics, COMSATS University Islamabad, Islamabad 45550, Pakistan
| | - Shamsul Qamar
- Department of Mathematics, COMSATS University Islamabad, Islamabad 45550, Pakistan
- Max Planck Institute for Dynamics of Complex Technical Systems, Magdeburg 39016, Germany
| | | |
Collapse
|
15
|
Numerical and analytical investigation of the possibilities to enhance the thermal conductivity of core-shell particle packed beds. J Chromatogr A 2018; 1575:26-33. [DOI: 10.1016/j.chroma.2018.08.056] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2018] [Revised: 08/23/2018] [Accepted: 08/30/2018] [Indexed: 12/31/2022]
|
16
|
Using Superficially Porous Particles and Ultrahigh Pressure Liquid Chromatography in Pharmacopeial Monograph Modernization of Common Analgesics. Chromatographia 2018. [DOI: 10.1007/s10337-018-3593-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
17
|
Lambert N, Felinger A. The effect of the frictional heat on retention and efficiency in thermostated or insulated chromatographic columns packed with sub-2-μm particles. J Chromatogr A 2018; 1565:89-95. [DOI: 10.1016/j.chroma.2018.06.038] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2018] [Revised: 06/11/2018] [Accepted: 06/16/2018] [Indexed: 11/28/2022]
|
18
|
Qamar S, Kiran N, Anwar T, Bibi S, Seidel-Morgenstern A. Theoretical Investigation of Thermal Effects in an Adiabatic Chromatographic Column Using a Lumped Kinetic Model Incorporating Heat Transfer Resistances. Ind Eng Chem Res 2018. [DOI: 10.1021/acs.iecr.7b04555] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Shamsul Qamar
- Max Planck Institute for Dynamics of Complex Technical Systems, Magdeburg 39106, Germany
- COMSATS Institute of Information Technology, Islamabad 45550, Pakistan
| | - Nadia Kiran
- COMSATS Institute of Information Technology, Islamabad 45550, Pakistan
| | - Talha Anwar
- COMSATS Institute of Information Technology, Islamabad 45550, Pakistan
| | - Sameena Bibi
- Air University, PAF Complex,
Sector E-9 Islamabad 44000, Pakistan
| | | |
Collapse
|
19
|
Helmueller SC, Poe DP, Kaczmarski K. Adiabatic packed column supercritical fluid chromatography using a dual-zone still-air column heater. J Chromatogr A 2018; 1535:141-153. [DOI: 10.1016/j.chroma.2018.01.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2017] [Revised: 12/29/2017] [Accepted: 01/02/2018] [Indexed: 11/29/2022]
|
20
|
Asnin LD, Stepanova MV. Van't Hoff analysis in chiral chromatography. J Sep Sci 2018; 41:1319-1337. [DOI: 10.1002/jssc.201701264] [Citation(s) in RCA: 47] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2017] [Revised: 12/27/2017] [Accepted: 12/28/2017] [Indexed: 11/11/2022]
Affiliation(s)
- Leonid D. Asnin
- Department of Chemistry and Biotechnology; Perm National Research Polytechnic University; Perm Russia
| | - Maria V. Stepanova
- Department of Chemistry and Biotechnology; Perm National Research Polytechnic University; Perm Russia
| |
Collapse
|
21
|
Broeckhoven K, Desmet G. Considerations for the use of ultra-high pressures in liquid chromatography for 2.1 mm inner diameter columns. J Chromatogr A 2017; 1523:183-192. [DOI: 10.1016/j.chroma.2017.07.040] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2017] [Revised: 07/10/2017] [Accepted: 07/11/2017] [Indexed: 10/19/2022]
|
22
|
Theoretical analysis of the influence of forced and inherent temperature fluctuations in an adiabatic chromatographic column. Chem Eng Sci 2017. [DOI: 10.1016/j.ces.2016.12.027] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
23
|
Horváth K, Horváth S, Lukács D. Effect of axial temperature gradient on chromatographic efficiency under adiabatic conditions. J Chromatogr A 2017; 1483:80-85. [DOI: 10.1016/j.chroma.2016.12.063] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2016] [Revised: 12/19/2016] [Accepted: 12/20/2016] [Indexed: 10/20/2022]
|
24
|
Bridging the gap between gas and liquid chromatography. J Chromatogr A 2016; 1472:107-116. [DOI: 10.1016/j.chroma.2016.10.038] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2016] [Revised: 10/10/2016] [Accepted: 10/13/2016] [Indexed: 11/24/2022]
|
25
|
Gritti F. Unexpected retention and efficiency behaviors in supercritical fluid chromatography: A thermodynamic interpretation. J Chromatogr A 2016; 1468:209-216. [DOI: 10.1016/j.chroma.2016.09.020] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2016] [Revised: 09/08/2016] [Accepted: 09/09/2016] [Indexed: 11/26/2022]
|
26
|
Gritti F, Fogwill M, Gilar M, Jarrell JA. Maximizing performance in supercritical fluid chromatography using low-density mobile phases. J Chromatogr A 2016; 1468:217-227. [DOI: 10.1016/j.chroma.2016.09.024] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2016] [Revised: 09/09/2016] [Accepted: 09/12/2016] [Indexed: 11/30/2022]
|