1
|
Chen Y, Guan H. Colorimetric detection of glucose in food using gold nanoparticles as nanoenzymes combined with a portable smartphone-assisted microfluidic paper-based analysis device. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2025; 329:125523. [PMID: 39674109 DOI: 10.1016/j.saa.2024.125523] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/05/2024] [Revised: 11/06/2024] [Accepted: 11/28/2024] [Indexed: 12/16/2024]
Abstract
Glucose is an important source of energy for the human body, but excessive intake will destroy the body's metabolic balance and increase health risks. In this paper, a smartphone glucose colorimetric detection system was developed in a paper-based microfluidic analytical device (µPAD) using green synthetic gold nanoparticles (AuNPs) as probes for accurate, rapid and efficient quantitative analysis of glucose in food. The AuNPs, acting as mimetic enzymes, were capable of catalyzing the breakdown of H2O2 generated by the interaction of glucose oxidase (GOx) with glucose to OH, which subsequently oxidized the 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS), resulting in a typical green reaction. This reaction was integrated into a µPAD and the color change on the paper chip was colorimetrically analyzed using a smartphone, with UV-Vis verification. Under optimal conditions, the sensor exhibited a linear range for detecting glucose from 0.050 to 5.250 mmol/L and a limit of detection (LOD) of 7.615 µmol/L. The developed approach showed no significant deviation from UV-Vis determination and has good selectivity, as well as proved to be effective for detecting glucose in real samples. This platform for glucose detection combines green synthesized AuNPs, μPAD and a smartphone app, offering features such as intelligence, portability, speed, low cost, high sensitivity and high selectivity. And it holds great potential for broad applications in the field of food analysis.
Collapse
Affiliation(s)
- Yanyu Chen
- College of Food Engineering, Harbin University of Commerce, Harbin 150076, China
| | - Huanan Guan
- School of Gain Science and Technology, Jiangsu University of Science and Technology, Zhenjiang 212100, China; College of Food Engineering, Harbin University of Commerce, Harbin 150076, China.
| |
Collapse
|
2
|
Bai CC, Lang JY, Wang XY, Zhao JM, Dong LY, Liu JJ, Wang XH. Fabrication of natural enzyme-covered / amino-modified Pd-Pt bimetallic-doped zeolitic imidazolate framework for ultrasensitive detection of metabolites. ANAL SCI 2025; 41:23-34. [PMID: 39363137 DOI: 10.1007/s44211-024-00670-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2024] [Accepted: 09/08/2024] [Indexed: 10/05/2024]
Abstract
The present article introduced an natural enzyme-covered/amino-modified Pd-Pt bimetallic-doped zeolitic imidazolate framework (NAPPZ) for ultrasensitive and specific detection of glucose. The dodecahedral nanomaterial zeolitic imidazolate framework (ZIF-8)-loaded Pd-Pt bimetallic nanoparticles endowed the composite with peroxidase-like activity. The modification with glucose oxidase (GOx) facilitated the rapid access of H2O2 produced through glucose oxidation to the Pd-Pt nanoparticles vicinity reducing diffusion. GOx specifically catalyzes the transformation of glucose into H2O2, which then H2O2 rapidly migrates to the Pd-Pt nanoparticles, catalyzing the oxidation of colorless o-phenylenediamine into the orange-yellow product 2,3-diaminophenazine. Based on the aforementioned cascade reaction, the NAPPZ and NAPPZ based on ChOx were utilized for detecting glucose in human urine samples and cholesterol in milk, respectively. The NAPPZ strategy presented a broad detection range (20-1100 μmol L-1) and a low detection limit (15.9 μmol L-1) for glucose, and the NAPPZ based on ChOx strategy approach offered a broad detection range (10-500 μmol L-1) and low detection limit (6.4 μmol L-1) for cholesterol. Therefore, this novel method holds significant potential in the areas of clinical diagnostics and food safety.
Collapse
Affiliation(s)
- Chen-Chen Bai
- Pharmacy Department of Tianjin Baodi Hospital, Tianjin Medical University Baodi Hospital, Tianjin, 301800, China
| | - Jin-Ye Lang
- Tianjin Key Laboratory On Technologies Enabling Development of Clinical Therapeutics and Diagnostics, Building B for School of Pharmacy, Tianjin Medical University, 22 Qixiangtai Road, Heping District, Tianjin, 300070, China
| | - Xin-Yu Wang
- Tianjin Key Laboratory On Technologies Enabling Development of Clinical Therapeutics and Diagnostics, Building B for School of Pharmacy, Tianjin Medical University, 22 Qixiangtai Road, Heping District, Tianjin, 300070, China
| | - Jia-Meng Zhao
- Tianjin Key Laboratory On Technologies Enabling Development of Clinical Therapeutics and Diagnostics, Building B for School of Pharmacy, Tianjin Medical University, 22 Qixiangtai Road, Heping District, Tianjin, 300070, China
| | - Lin-Yi Dong
- Tianjin Key Laboratory On Technologies Enabling Development of Clinical Therapeutics and Diagnostics, Building B for School of Pharmacy, Tianjin Medical University, 22 Qixiangtai Road, Heping District, Tianjin, 300070, China
| | - Jun-Jie Liu
- Pharmacy Department of Tianjin Baodi Hospital, Tianjin Medical University Baodi Hospital, Tianjin, 301800, China.
| | - Xian-Hua Wang
- Tianjin Key Laboratory On Technologies Enabling Development of Clinical Therapeutics and Diagnostics, Building B for School of Pharmacy, Tianjin Medical University, 22 Qixiangtai Road, Heping District, Tianjin, 300070, China.
| |
Collapse
|
3
|
Feng C, Chen Z, Yin H, Gong J, Wang H, Wu S, Wang L. Construction of Pt/Ni/NiFe 2O 4/C nanocomposite with one dimensional hollow structure for portable glucose sensing application. ANAL SCI 2024; 40:1437-1448. [PMID: 38671292 DOI: 10.1007/s44211-024-00578-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2024] [Accepted: 04/08/2024] [Indexed: 04/28/2024]
Abstract
Designing portable electrochemical sensors combined with highly efficient glucose oxidation electrodes offers a significant opportunity for convenient glucose detection. In this report, we present the design and preparation of platinum deposited Ni/NiFe2O4/Carbon composite (Pt/Ni/NiFe2O4/C) derived from Ni/Fe metal-organic frameworks (MOFs) followed by Pt deposition. Energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), X-ray diffraction (XRD), and electron microscopy (EM) were utilized to analyze the crystal structure, morphology, and chemical composition of the resulting materials. The glucose sensing capabilities of the optimal Pt/Ni/NiFe2O4/C-3 were assessed using amperometry methods on a smartphone-based portable device. Acting as a nonenzymatic glucose sensor, the Pt/Ni/NiFe2O4/C-3 electrode demonstrated notable sensitivity and a low limit of detection for glucose. The portable sensor exhibits high sensitivities of 131.88 μM mM cm-2 at low glucose concentration (3-500 μM) and 29.52 μA mM cm-2 at high glucose concentration (700-4000 μM), achieving a low detection limit of 1.1 μM (S/N = 3). The sensor also demonstrates enhanced selectivity and stability for detecting glucose. Furthermore, the portable sensor exhibits a clear step-ampere response in the detection of serum samples with satisfactory recovery ranging from 99.30 to 101.32%. This suggests the significant potential of portable glucose sensing applications.
Collapse
Affiliation(s)
- Chengqi Feng
- Key Laboratory of Micro-Nano Sensing and IoT of Wenzhou, Wenzhou Institute of Hangzhou Dianzi University, Wenzhou, 325038, People's Republic of China
| | - Zhiyuan Chen
- Key Laboratory of Micro-Nano Sensing and IoT of Wenzhou, Wenzhou Institute of Hangzhou Dianzi University, Wenzhou, 325038, People's Republic of China
| | - Haoyong Yin
- Key Laboratory of Micro-Nano Sensing and IoT of Wenzhou, Wenzhou Institute of Hangzhou Dianzi University, Wenzhou, 325038, People's Republic of China.
| | - Jianying Gong
- Key Laboratory of Micro-Nano Sensing and IoT of Wenzhou, Wenzhou Institute of Hangzhou Dianzi University, Wenzhou, 325038, People's Republic of China
| | - Hui Wang
- Key Laboratory of Micro-Nano Sensing and IoT of Wenzhou, Wenzhou Institute of Hangzhou Dianzi University, Wenzhou, 325038, People's Republic of China
| | - Shengji Wu
- College of Engineering, Huzhou University, Huzhou, 313000, China.
| | - Ling Wang
- Department of Chemistry, Zhejiang Sci-Tech University, Hangzhou, 310018, People's Republic of China
| |
Collapse
|
4
|
He L, Su J, You T, Xiao S, Huang P, He D, Jiang P. Rapid and facile preparation of NiFe-layered double hydroxide nanosheets as self-supported electrode for glucose detection in drink sample. Food Chem 2024; 439:138163. [PMID: 38091783 DOI: 10.1016/j.foodchem.2023.138163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 12/01/2023] [Accepted: 12/05/2023] [Indexed: 01/10/2024]
Abstract
Layered double hydroxides have been widely used for electrochemical glucose detection due to their layered structure with more active sites, but they suffer from lower electrical conductivity and long-time hydrothermal preparation. In this paper, NiFe-layered double hydroxide nanosheets supported on nickel foam (NiFe-LDH NSs/NF) was prepared using an ultrafast and facile method via in-situ corroding foam nickel in FeCl3 solution under room temperature, and the whole synthetic process can be accomplished within several minutes. The as-fabricated NiFe-LDH NSs/NF shows significant catalytic activity in the glucose oxidation, showing its great promise in glucose detection. As a self-supported electrode, NiFe-LDH NSs/NF is favorable for glucose detection, with a sensitivity of 9.79 and 3.29 mA mM-1 cm-2 within the linear range of 0.001 to 1.16 mM and 1.16 to 4.67 mM, respectively. Moreover, NiFe-LDH NSs/NF is also selective and reliable towards glucose detection in drink sample.
Collapse
Affiliation(s)
- Liu He
- Chongqing Key Laboratory of Inorganic Functional Materials, College of Chemistry, Chongqing Normal University, Chongqing 401331, China
| | - Jiangyu Su
- Chongqing Key Laboratory of Inorganic Functional Materials, College of Chemistry, Chongqing Normal University, Chongqing 401331, China
| | - Teng You
- Chongqing Key Laboratory of Inorganic Functional Materials, College of Chemistry, Chongqing Normal University, Chongqing 401331, China
| | - Shuang Xiao
- Chongqing Key Laboratory of Inorganic Functional Materials, College of Chemistry, Chongqing Normal University, Chongqing 401331, China
| | - Ping Huang
- Chongqing Key Laboratory of Inorganic Functional Materials, College of Chemistry, Chongqing Normal University, Chongqing 401331, China
| | - Daiping He
- Chongqing Key Laboratory of Inorganic Functional Materials, College of Chemistry, Chongqing Normal University, Chongqing 401331, China
| | - Ping Jiang
- Chongqing Key Laboratory of Inorganic Functional Materials, College of Chemistry, Chongqing Normal University, Chongqing 401331, China.
| |
Collapse
|
5
|
Ali MY, Abdulrahman HB, Ting WT, Howlader MMR. Green synthesized gold nanoparticles and CuO-based nonenzymatic sensor for saliva glucose monitoring. RSC Adv 2024; 14:577-588. [PMID: 38173614 PMCID: PMC10758929 DOI: 10.1039/d3ra05644a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Accepted: 11/30/2023] [Indexed: 01/05/2024] Open
Abstract
Glucose, essential for brain and muscle functions, requires careful monitoring in diabetes and other chronic disease management. While blood glucose monitoring provides precise information about these diseases, it remains an invasive method. Saliva glucose monitoring could offer an alternative approach, but the glucose concentration in saliva is very low. In this work, we report a simple, low-cost, highly sensitive nonenzymatic electrochemical glucose sensor. We developed this sensor using green synthesized gold nanoparticles (AuNPs) and wet chemical synthesized copper oxide (CuO) nanoparticles on a screen-printed carbon electrode (Au/CuO/SPCE). The sensor's high sensitivity results from dual amplification strategies using AuNPs and CuO nanomaterials, each demonstrating catalytic activity towards glucose. This shows promising potential for saliva glucose monitoring. The AuNPs were synthesized using an Au precursor and orange peel extract (OPE), yielding stable colloidal AuNPs with a mean diameter of about 37 nm, thus eliminating the need for additional capping agents. Under optimal conditions, amperometric tests revealed that the sensor responded linearly to glucose concentrations ranging from 2 μM to 397 μM with a sensitivity of 236.70 μA mM-1 cm-2. Furthermore, the sensor demonstrated excellent reproducibility, stability and high selectivity for glucose in the presence of different biomolecules. We validated the sensor's efficacy by measuring glucose in human saliva, showing its potential for noninvasive glucose monitoring. This research advances the development of point-of-care devices, positioning the sensor as a promising tool for noninvasive glucose monitoring and improved diabetes management.
Collapse
Affiliation(s)
- Md Younus Ali
- Department of Electrical and Computer Engineering, McMaster University 1280 Main Street West Hamilton ON L8S 4K1 Canada
| | - Heman B Abdulrahman
- Department of Electrical and Computer Engineering, McMaster University 1280 Main Street West Hamilton ON L8S 4K1 Canada
| | - Wei-Ting Ting
- Department of Electrical and Computer Engineering, McMaster University 1280 Main Street West Hamilton ON L8S 4K1 Canada
| | - Matiar M R Howlader
- Department of Electrical and Computer Engineering, McMaster University 1280 Main Street West Hamilton ON L8S 4K1 Canada
| |
Collapse
|
6
|
Kim SE, Yoon JC, Tae HJ, Muthurasu A. Electrospun Manganese-Based Metal-Organic Frameworks for MnO x Nanostructures Embedded in Carbon Nanofibers as a High-Performance Nonenzymatic Glucose Sensor. ACS OMEGA 2023; 8:42689-42698. [PMID: 38024713 PMCID: PMC10652823 DOI: 10.1021/acsomega.3c05459] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Revised: 10/15/2023] [Accepted: 10/17/2023] [Indexed: 12/01/2023]
Abstract
Material-specific electrocatalytic activity and electrode design are essential factors in evaluating the performance of electrochemical sensors. Herein, the technique described involves electrospinning manganese-based metal-organic frameworks (Mn-MOFs) to develop MnOx nanostructures embedded in carbon nanofibers. The resulting structure features an electrocatalytic material for an enzyme-free glucose sensor. The elemental composition, morphology, and microstructure of the fabricated electrodes materials were characterized by using energy-dispersive X-ray spectroscopy (EDX), field-emission scanning electron microscopy (FESEM), and transmission electron microscopy (TEM). Cyclic voltammetry (CV) and amperometric i-t (current-time) techniques are characteristically employed to assess the electrochemical performance of materials. The MOF MnOx-CNFs nanostructures significantly improve detection performance for nonenzymatic amperometric glucose sensors, including a broad linear range (0 mM to 9.1 mM), high sensitivity (4080.6 μA mM-1 cm-2), a low detection limit (0.3 μM, S/N = 3), acceptable selectivity, outstanding reproducibility, and stability. The strategy of metal and metal oxide-integrated CNF nanostructures based on MOFs opens interesting possibilities for the development of high-performance electrochemical sensors.
Collapse
Affiliation(s)
- So Eun Kim
- Department
of Emergency Medicine, Research Institute
of Clinical Medicine of Jeonbuk National University and Biomedical
Research Institute of Jeonbuk National University Hospital, Jeonju 54907, Republic of Korea
| | - Jae Chol Yoon
- Department
of Emergency Medicine, Research Institute
of Clinical Medicine of Jeonbuk National University and Biomedical
Research Institute of Jeonbuk National University Hospital, Jeonju 54907, Republic of Korea
| | - Hyun-Jin Tae
- College
of Veterinary Medicine and Biosafety Research Institute, Jeonbuk National University, Iksan 54596, Republic of Korea
| | - Alagan Muthurasu
- Department
of Nano Convergence Technology, Jeonbuk
National University, Jeonju 54907, Republic
of Korea
| |
Collapse
|
7
|
Li J, Mahdavi B, Baghayeri M, Rivandi B, Lotfi M, Mahdi Zangeneh M, Zangeneh A, Tayebee R. A new formulation of Ni/Zn bi-metallic nanocomposite and evaluation of its applications for pollution removal, photocatalytic, electrochemical sensing, and anti-breast cancer. ENVIRONMENTAL RESEARCH 2023; 233:116462. [PMID: 37352956 DOI: 10.1016/j.envres.2023.116462] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Revised: 06/17/2023] [Accepted: 06/17/2023] [Indexed: 06/25/2023]
Abstract
Nanocomposites have gained attention due to their variety of applications in different fields. In this research, we have reported a green synthesis of a bi-metallic nanocomposite of nickel and zinc using an aqueous extract of Citrus sinensis in the presence of chitosan (Ni/Zn@orange/chitosan). The nanocomposite was characterized using different techniques. We have examined various applications for Ni/Zn@orange/chitosan. The NPs were manufactured in spherical morphology with a particle range size of 17.34-90.51 nm. Ni/Zn@orange/chitosan showed an acceptable ability to remove dyes of Congo red and methyl orange from an aqueous solution after 80 min furthermore, it uptaking the drug mefenamic acid from a solution. Ni/Zn@orange/chitosan also exhibited great photocatalytic activity in synthesizing benzimidazole using benzyl alcohol and o-phenylenediamine. Ni/Zn@orange/chitosan was found as a potent electrochemical sensor to determine glucose. In the molecular and cellular section of the current research, the cells with composite nanoparticles were studied by MTT way about the anti-breast adenocarcinoma potentials malignant cell lines. The IC50 of composite nanoparticles were 320, 460, 328, 500, 325, 379, 350, and 396 μg/mL concering RBA, NMU, SK-BR-3, CAMA-1, MCF7, AU565, MDA-MB-468, and Hs 281.T breast adenocarcinoma cell lines, respectively. The results revealed the newly synthesized nanocomposite is a potent photocatalyst, dye pollution removal agent, and an acceptable new drug to treat breast cancer.
Collapse
Affiliation(s)
- Jia Li
- Department of Breast Surgery, Shanxi Province Cancer Hospital, Shanxi Hospital Affiliated to Cancer Hospital, Chinese Academy of Medical Sciences, Cancer Hospital Affiliated to Shanxi Medical University, Taiyuan, Shanxi Province, 030013, China.
| | - Behnam Mahdavi
- Department of Chemistry, Faculty of Science, Hakim Sabzevari University, Sabzevar, Iran.
| | - Mehdi Baghayeri
- Department of Chemistry, Faculty of Science, Hakim Sabzevari University, Sabzevar, Iran.
| | - Behnaz Rivandi
- Department of Chemistry, Faculty of Science, Hakim Sabzevari University, Sabzevar, Iran
| | - Maryam Lotfi
- Department of Chemistry, Faculty of Science, Hakim Sabzevari University, Sabzevar, Iran
| | - Mohammad Mahdi Zangeneh
- Biotechnology and Medicinal Plants Research Center, Ilam University of Medical Sciences, Ilam, Iran
| | - Akram Zangeneh
- Biotechnology and Medicinal Plants Research Center, Ilam University of Medical Sciences, Ilam, Iran
| | - Reza Tayebee
- Department of Chemistry, Faculty of Science, Hakim Sabzevari University, Sabzevar, Iran
| |
Collapse
|
8
|
Elancheziyan M, Prakasham K, Eswaran M, Duraisamy M, Ganesan S, Lee SL, Ponnusamy VK. Eco-friendly fabrication of nonenzymatic electrochemical sensor based on cobalt/polymelamine/nitrogen-doped graphitic-porous carbon nanohybrid material for glucose monitoring in human blood. ENVIRONMENTAL RESEARCH 2023; 223:115403. [PMID: 36754108 DOI: 10.1016/j.envres.2023.115403] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/23/2022] [Revised: 12/27/2022] [Accepted: 01/30/2023] [Indexed: 06/18/2023]
Abstract
The design and development of eco-friendly fabrication of cost-effective electrochemical nonenzymatic biosensors with enhanced sensitivity and selectivity are one of the emerging area in nanomaterial and analytical chemistry. In this aspect, we developed a facile fabrication of tertiary nanocomposite material based on cobalt and polymelamine/nitrogen-doped graphitic porous carbon nanohybrid composite (Co-PM-NDGPC/SPE) for the application as a nonenzymatic electrochemical sensor to quantify glucose in human blood samples. Co-PM-NDGPC/SPE nanocomposite electrode fabrication was achieved using a single-step electrodeposition method under cyclic voltammetry (CV) technique under 1 M NH4Cl solution at 20 constitutive CV cycles (sweep rate 20 mV/s). Notably, the fabricated nonenzymatic electroactive nanocomposite material exhibited excellent electrocatalytic sensing towards the quantification of glucose in 0.1 M NaOH over a wide concentration range from 0.03 to 1.071 mM with a sensitive limit of detection 7.8 μM. Moreover, the Co-PM-NDGPC nanocomposite electrode with low charge transfer resistance (Rct∼81 Ω) and high ionic diffusion indicates excellent stability, reproducibility, and high sensitivity. The fabricated nanocomposite materials exhibit a commendable sensing response toward glucose molecules present in the blood serum samples recommends its usage in real-time applications.
Collapse
Affiliation(s)
- Mari Elancheziyan
- Department of Medicinal and Applied Chemistry, Kaohsiung Medical University, Kaohsiung City-807, Taiwan; Department of Chemistry, Saveetha School of Engineering, Saveetha Institute of Medical and Technical Sciences (SIMATS), Thandalam-602105, India
| | - Karthikeyan Prakasham
- Research Center for Precision Environmental Medicine, Kaohsiung Medical University, Kaohsiung City-807, Taiwan
| | - Muthusankar Eswaran
- Department of Medicinal and Applied Chemistry, Kaohsiung Medical University, Kaohsiung City-807, Taiwan; Department of Biology and Biological Engineering, Chalmers University of Technology, Gothenburg, Sweden
| | - Murugesan Duraisamy
- Research Center for Precision Environmental Medicine, Kaohsiung Medical University, Kaohsiung City-807, Taiwan; SSN Research Centre, SSN College of Engineering, Kalavakkam-603110, India
| | - Sivarasan Ganesan
- Department of Medicinal and Applied Chemistry, Kaohsiung Medical University, Kaohsiung City-807, Taiwan
| | - Siew Ling Lee
- Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia; Centre for Sustainable Nanomaterials, Ibnu Sina Institute for Scientific and Industrial Research, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia.
| | - Vinoth Kumar Ponnusamy
- Department of Medicinal and Applied Chemistry, Kaohsiung Medical University, Kaohsiung City-807, Taiwan; Research Center for Precision Environmental Medicine, Kaohsiung Medical University, Kaohsiung City-807, Taiwan; Department of Chemistry, National Sun Yat-sen University, Kaohsiung City-804, Taiwan; Department of Medical Research, Kaohsiung Medical University Hospital (KMUH), Kaohsiung City-807, Taiwan.
| |
Collapse
|
9
|
Luminescent lanthanide metallogel as a sensor array to efficiently discriminate various saccharides. J Mol Liq 2023. [DOI: 10.1016/j.molliq.2023.121447] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/15/2023]
|
10
|
Koyappayil A, Yeon SH, Chavan SG, Jin L, Go A, Lee MH. Efficient and rapid synthesis of ultrathin nickel-metal organic framework nanosheets for the sensitive determination of glucose. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107462] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
11
|
Chen T, Zhao P, Li J, Sun Z, Huang W. Construction of a novel Co-based coordination polymer and its study of non-enzymatic glucose sensors. J SOLID STATE CHEM 2022. [DOI: 10.1016/j.jssc.2022.123115] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
12
|
Enzyme Encapsulation by Facile Self-Assembly Silica-Modified Magnetic Nanoparticles for Glucose Monitoring in Urine. Pharmaceutics 2022; 14:pharmaceutics14061154. [PMID: 35745727 PMCID: PMC9227432 DOI: 10.3390/pharmaceutics14061154] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Revised: 05/21/2022] [Accepted: 05/25/2022] [Indexed: 12/10/2022] Open
Abstract
Silica nanoparticles hold tremendous potential for the encapsulation of enzymes. However, aqueous alcohol solutions and catalysts are prerequisites for the production of silica nanoparticles, which are too harsh for maintaining the enzyme activity. Herein, a procedure without any organic solvents and catalysts (acidic or alkaline) is developed for the synthesis of silica-encapsulated glucose-oxidase-coated magnetic nanoparticles by a facile self-assembly route, avoiding damage of the enzyme structure in the reaction system. The encapsulated enzyme was characterized by scanning electron microscopy, transmission electron microscopy, energy-dispersive spectrometry, and a vibrating sample magnetometer. Finally, a colorimetric sensing method was developed for the detection of glucose in urine samples based on the encapsulated glucose oxidase and a hydrogen peroxide test strip. The method exhibited a good linear performance in the concentration range of 20~160 μg mL−1 and good recoveries ranging from 94.3 to 118.0%. This work proves that the self-assembly method could be employed to encapsulate glucose oxidase into silica-coated magnetic particles. The developed colorimetric sensing method shows high sensitivity, which will provide a promising tool for the detection of glucose and the monitoring of diabetes.
Collapse
|
13
|
Drissi W, Chelaghmia ML, NACEF MOUNA, Affoune A, Satha H, Kihal R, Fisli H, Boukharouba C, Pontié M. In situ growth of Ni(OH)<sub>2 </sub>nanoparticles on 316L stainless steel foam: An efficient three‐dimensional non‐enzymatic glucose electrochemical sensor in real human blood serum samples. ELECTROANAL 2022. [DOI: 10.1002/elan.202100701] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Affiliation(s)
| | | | - MOUNA NACEF
- Laboratoire danalyses industrielles et genie des materiaux ALGERIA
| | | | | | | | | | - Chahira Boukharouba
- Université 8 Mai 1945 Guelma Faculté des Sciences et de la Technologie ALGERIA
| | | |
Collapse
|
14
|
Zhang M, Cui X, Li N. Smartphone-based mobile biosensors for the point-of-care testing of human metabolites. Mater Today Bio 2022; 14:100254. [PMID: 35469257 PMCID: PMC9034388 DOI: 10.1016/j.mtbio.2022.100254] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2022] [Revised: 03/14/2022] [Accepted: 03/31/2022] [Indexed: 11/29/2022] Open
Abstract
Rapid, accurate, portable and quantitative profiling of metabolic biomarkers is of great importance for disease diagnosis and prognosis. The recent development in the optical and electric biosensors based on the smartphone is promising for profiling of metabolites with advantages of rapid, reliability, accuracy, low-cost and multi-analytes analysis capability. In this review, we introduced the optical biosensing platforms including colorimetric, fluorescent and chemiluminescent sensing, and electrochemical biosensing platforms including wired and wireless communication. Challenges and future perspectives desired for reliable, accurate, cost-effective, and multi-functions smartphone-based biosensing systems were also discussed. We envision that such smartphone-based biosensing platforms will allow daily and comprehensive metabolites monitoring in the future, thus unlocking the potential to transform clinical diagnostics into non-clinical self-testing. We also believed that this progress report will encourage future research to develop advanced, integrated and multi-functional smartphone-based Point-of-Care testing (POCT) biosensors for the monitoring and diagnosis as well as personalized treatments of a spectrum of metabolic-disorder related diseases.
Collapse
|
15
|
Hu T, Wang D, Xu J, Chen K, Li X, Yi H, Ni Z. Glucose sensing on screen-printed electrochemical electrodes based on porous graphene aerogel @prussian blue. Biomed Microdevices 2022; 24:14. [PMID: 35218431 DOI: 10.1007/s10544-022-00614-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/01/2022] [Indexed: 12/24/2022]
Abstract
As one of the three major chronic diseases, diabetes often causes many complications, which can affect various parts of the body and even threaten the life of the patients. At present, the situation of diabetes in the world is quite serious. Accurate detection of blood glucose is very important for the diagnosis, treatment and medication of diabetes as well as the self-management of diabetic patients. In this paper, an electrochemical glucose biosensor was developed based on screen-printed electrode (SPE) modified with composite material of graphene aerogel (GA) and Prussian blue (PB) (denoted as GA@PB), which was fabricated via chemical reduction using L-ascorbic acid as a reducing agent through a freeze-drying process. Glucose was specifically captured by glucose oxidase (GOx) which were immobilized into the GA@PB by chitosan. The structure and performance of the sensor were characterized by scanning electron microscopy (SEM), Raman spectroscopy measurements, Fourier transform infrared spectrometer (FTIR), cyclic voltammetry (CV) and amperometric detection. The sensor exhibited a linear range of 0.5-6.0 mmol·L-1 with limit of detection (LOD) of 0.15 mmol·L-1, indicating that the combination of graphene aerogel and Prussian blue possess well conductivity and catalytic performance.
Collapse
Affiliation(s)
- Tao Hu
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China
| | - Di Wang
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China
| | - Jian Xu
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China
| | - Ke Chen
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China
| | - Xiao Li
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China.
| | - Hong Yi
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China.
| | - Zhonghua Ni
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China.
| |
Collapse
|
16
|
Murugan P, Annamalai J, Atchudan R, Govindasamy M, Nallaswamy D, Ganapathy D, Reshetilov A, Sundramoorthy AK. Electrochemical Sensing of Glucose Using Glucose Oxidase/PEDOT:4-Sulfocalix [4]arene/MXene Composite Modified Electrode. MICROMACHINES 2022; 13:mi13020304. [PMID: 35208428 PMCID: PMC8877456 DOI: 10.3390/mi13020304] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Revised: 02/09/2022] [Accepted: 02/13/2022] [Indexed: 12/12/2022]
Abstract
Glucose is one of the most important monosaccharides found in the food, as a part of more complex structures, which is a primary energy source for the brain and body. Thus, the monitoring of glucose concentration is more important in food and biological samples in order to maintain a healthy lifestyle. Herein, an electrochemical glucose biosensor was fabricated by immobilization of glucose oxidase (GOX) onto poly(3,4-ethylenedioxythiophene):4-sulfocalix [4]arene (PEDOT:SCX)/MXene modified electrode. For this purpose, firstly, PEDOT was synthesized in the presence of SCX (counterion) by the chemical oxidative method. Secondly, MXene (a 2D layered material) was synthesized by using a high-temperature furnace under a nitrogen atmosphere. After that, PEDOT:SCX/MXene (1:1) dispersion was prepared by ultrasonication which was later utilized to prepare PEDOT:SCX/MXene hybrid film. A successful formation of PEDOT:SCX/MXene film was confirmed by HR-SEM, Fourier transform infrared (FT-IR), and Raman spectroscopies. Due to the biocompatibility nature, successful immobilization of GOX was carried out onto chitosan modified PEDOT:SCX/MXene/GCE. Moreover, the electrochemical properties of PEDOT:SCX/MXene/GOX/GCE was studied through cyclic voltammetry and amperometry methods. Interestingly, a stable redox peak of FAD-GOX was observed at a formal potential of –0.435 V on PEDOT:SCX/MXene/GOX/GCE which indicated a direct electron transfer between the enzyme and the electrode surface. PEDOT:SCX/MXene/GOX/GCE also exhibited a linear response against glucose concentrations in the linear range from 0.5 to 8 mM. The effect of pH, sensors reproducibility, and repeatability of the PEDOT:SCX/MXene/GOX/GCE sensor were studied. Finally, this new biosensor was successfully applied to detect glucose in commercial fruit juice sample with satisfactory recovery.
Collapse
Affiliation(s)
- Preethika Murugan
- Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur 603203, Tamil Nadu, India;
| | - Jayshree Annamalai
- Department of Biotechnology, SRM Institute of Science and Technology, Kattankulathur 603203, Tamil Nadu, India;
| | - Raji Atchudan
- School of Chemical Engineering, Yeungnam University, Gyeongsan 38541, Korea;
| | - Mani Govindasamy
- Department of Materials Engineering, Ming-Chi University of Technology, New Taipei City 243, Taiwan;
| | - Deepak Nallaswamy
- Department of Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Poonamallee High Road, Velappanchavadi, Chennai 600077, Tamil Nadu, India; (D.N.); (D.G.)
| | - Dhanraj Ganapathy
- Department of Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Poonamallee High Road, Velappanchavadi, Chennai 600077, Tamil Nadu, India; (D.N.); (D.G.)
| | - Anatoly Reshetilov
- G.K. Skryabin Institute of Biochemistry and Physiology of Microorganisms, Pushchino Centre for Biological Research, Russian Academy of Sciences, 142290 Pushchino, Russia;
| | - Ashok K. Sundramoorthy
- Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur 603203, Tamil Nadu, India;
- Department of Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Poonamallee High Road, Velappanchavadi, Chennai 600077, Tamil Nadu, India; (D.N.); (D.G.)
- Correspondence:
| |
Collapse
|
17
|
A highly sensitive non-enzymatic glucose sensor based on CuNi nanoalloys through one-step electrodeposition strategy. J APPL ELECTROCHEM 2022. [DOI: 10.1007/s10800-022-01671-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
18
|
Yan L, Chu D, Chu XQ, Ge D, Chen X. Co/CoO nanoparticles armored by N-doped nanoporous carbon polyhedrons towards glucose oxidation in high-performance non-enzymatic sensors. NEW J CHEM 2022. [DOI: 10.1039/d2nj02490j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The Co/CoO nanoparticles armored by porous N-doped carbon polyhedrons were successfully prepared from ZIF-67 via a pyrolysis-reorganization method, demonstrating excellent sensing performance towards glucose oxidation.
Collapse
Affiliation(s)
- Li Yan
- College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing, 211800, P. R. China
| | - Dandan Chu
- College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing, 211800, P. R. China
| | - Xue-Qiang Chu
- College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing, 211800, P. R. China
| | - Danhua Ge
- College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing, 211800, P. R. China
| | - Xiaojun Chen
- College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing, 211800, P. R. China
- Jiangsu Key Laboratory of Molecular Biology for Skin Diseases and STIs, Nanjing, 210042, P. R. China
| |
Collapse
|
19
|
Hu Q, Qin J, Wang XF, Ran GY, Wang Q, Liu GX, Ma JP, Ge JY, Wang HY. Cu-Based Conductive MOF Grown in situ on Cu Foam as a Highly Selective and Stable Non-Enzymatic Glucose Sensor. Front Chem 2021; 9:786970. [PMID: 34912785 PMCID: PMC8666423 DOI: 10.3389/fchem.2021.786970] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Accepted: 11/04/2021] [Indexed: 11/16/2022] Open
Abstract
A non-enzymatic electrochemical sensor for glucose detection is executed by using a conductive metal–organic framework (MOF) Cu-MOF, which is built from the 2,3,6,7,10,11-hexahydroxytriphenylene (HHTP) ligand and copper acetate by hydrothermal reaction. The Cu-MOF demonstrates superior electrocatalytic activity for glucose oxidation under alkaline pH conditions. As an excellent non-enzymatic sensor, the Cu-MOF grown on Cu foam (Cu-MOF/CF) displays an ultra-low detection limit of 0.076 μM through a wide concentration range (0.001–0.95 mM) and a strong sensitivity of 30,030 mA μM−1 cm−2. Overall, the Cu-MOF/CF exhibits a low detection limit, high selectivity, excellent stability, fast response time, and good practical application feasibility for glucose detection and can promote the development of MOF materials in the field of electrochemical sensors.
Collapse
Affiliation(s)
- Qin Hu
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, China
| | - Jie Qin
- School of Life Sciences and Medicine, Shandong University of Technology, Zibo, China
| | - Xiao-Feng Wang
- School of Environmental Science, Nanjing Xiaozhuang University, Nanjing, China
| | - Guang-Ying Ran
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, China
| | - Qiang Wang
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, China
| | - Guang-Xiang Liu
- School of Environmental Science, Nanjing Xiaozhuang University, Nanjing, China
| | - Jian-Ping Ma
- School of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan, China
| | - Jing-Yuan Ge
- College of Chemistry and Materials Engineering, Wenzhou University, Wenzhou, China
| | - Hai-Ying Wang
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, China.,School of Environmental Science, Nanjing Xiaozhuang University, Nanjing, China
| |
Collapse
|
20
|
A molecularly imprinted electrochemical biosensor based on hierarchical Ti 2Nb 10O 29 (TNO) for glucose detection. Mikrochim Acta 2021; 189:24. [PMID: 34894290 DOI: 10.1007/s00604-021-05128-x] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Accepted: 12/02/2021] [Indexed: 10/19/2022]
Abstract
A novel molecularly imprinted electrochemical biosensor for glucose detection is reported based on a hierarchical N-rich carbon conductive-coated TNO structure (TNO@NC). Firstly, TNO@NC was fabricated by a novel polypyrrole-chemical vapor deposition (PPy-CVD) method with minimal waste generation. Afterward, the electrode modification with TNO@NC was performed by dropping TNO@NC particles on glassy carbon electrode surfaces by infrared heat lamp. Finally, the glucose-imprinted electrochemical biosensor was developed in presence of 75.0 mM pyrrole and 25.0 mM glucose in a potential range from + 0.20 to + 1.20 V versus Ag/AgCl via cyclic voltammetry (CV). The physicochemical and electrochemical characterizations of the fabricated molecularly imprinted biosensor was conducted by transmission electron microscopy (TEM), scanning electron microscopy (SEM), X-ray diffraction (XRD) method, X-ray photoelectron spectroscopy (XPS), electrochemical impedance spectroscopy (EIS), and CV techniques. The findings demonstrated that selective, sensitive, and stable electrochemical signals were proportional to different glucose concentrations, and the sensitivity of molecularly imprinted electrochemical biosensor for glucose detection was estimated to be 18.93 μA μM-1 cm-2 (R2 = 0.99) at + 0.30 V with the limit of detection (LOD) of 1.0 × 10-6 M. Hence, it can be speculated that the fabricated glucose-imprinted biosensor may be used in a multitude of areas, including public health and food quality.
Collapse
|
21
|
Chu D, Yan L, Chen Q, Chu XQ, Ge D, Chen X. Efficient improvement in non-enzymatic glucose detection induced by the hollow prism-like NiCo 2S 4 electrocatalyst. Dalton Trans 2021; 50:15162-15169. [PMID: 34617534 DOI: 10.1039/d1dt02371c] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Hollow prism-like NiCo2S4 materials (NiCo2S4 HNPs) were successfully fabricated by a two-step method. Scanning electron microscopy (SEM), transmission electron microscopy (TEM) and powder X-ray diffraction (XRD) confirmed the morphology and structure of the as-prepared NiCo2S4 nanoprisms. A non-enzymatic sensor based on NiCo2S4 HNPs was constructed with outstanding electrochemical activity towards glucose oxidation in alkaline medium. The sensor showed a rapid response time (∼0.1 s), a high sensitivity of 82.9 μA mM-1 cm-2, a wide linear range (0.005-20.2 mM) and a detection limit of 0.8 μM (S/N = 3) with a good selectivity and reproducibility. Additionally, the proposed electrode also confirmed the feasibility in practical blood serum. These results indicate that NiCo2S4/ITO has great potential in the development of non-enzymatic glucose sensor applications.
Collapse
Affiliation(s)
- Dandan Chu
- College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing, 211800, PR China.
| | - Li Yan
- College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing, 211800, PR China.
| | - Qiwen Chen
- College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing, 211800, PR China.
| | - Xue-Qiang Chu
- College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing, 211800, PR China.
| | - Danhua Ge
- College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing, 211800, PR China.
| | - Xiaojun Chen
- College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing, 211800, PR China.
| |
Collapse
|
22
|
Zhang C, Yao H, Ma Q, Yu B. Ultrasensitive glucose detection from tears and saliva through integrating a glucose oxidase-coupled DNAzyme and CRISPR-Cas12a. Analyst 2021; 146:6576-6581. [PMID: 34586111 DOI: 10.1039/d1an01385h] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The accurate and sensitive detection of glucose from secretory clinical samples, such as tears and saliva, remains a great challenge. In this research, a novel ultrasensitive glucose detection method consisting of a glucose oxidase (GOx), pistol-like DNAzyme (PLDz), and CRISPR-Cas12a system is proposed. First, the oxidation of glucose catalyzed by GOx leads to the production of H2O2; the self-cleavage activity of PLDz is activated after recognition of the produced H2O2. The two procedures triggered by COx and PLDz play an important role in accurately identifying glucose and converting glucose signals to nucleic acids. The obtained PLDz fragments can be recognized by the Cas12 enzyme and thus activate the trans-cleavage activity of the Cas12a enzyme. Finally, the surrounding reporter probes are cut by the Cas12a enzyme to produce fluorescence signals. In summary, an ultra-sensitive and specific fluorescence method has been developed for glucose detection from secretory clinical samples, which could potentially contribute to the noninvasive diagnosis of diabetes mellitus.
Collapse
Affiliation(s)
- Caiying Zhang
- Department of Endocrinology, Zhuji Affiliated Hospital of Shaoxing University, Zhuji City, Zhejiang Province, 311800, China
| | - Hongfeng Yao
- Department of Clinical Laboratory, Zhuji Affiliated Hospital of Shaoxing University, Zhuji City, Zhejiang Province, 311800, China
| | - Qiang Ma
- Department of Endocrinology, Zhuji Affiliated Hospital of Shaoxing University, Zhuji City, Zhejiang Province, 311800, China
| | - Bin Yu
- Department of medical administration, the Second Affiliated Hospital of Zhejiang University, Hangzhou City, Zhejiang Province, 312000, China.
| |
Collapse
|
23
|
Chen L, Huang X, Zeng X, Fang G, Chen W, Zhou H, Zhong X, Cai H. Signal-on bimodal sensing glucose based on enzyme product-etching MnO2 nanosheets for detachment of MoS2 quantum dots. CHINESE CHEM LETT 2021. [DOI: 10.1016/j.cclet.2021.01.030] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
24
|
Xu Z, Wang Q, Li R, Zhangsun H, Dong M, Wang L. Surface Selenylation Engineering for Construction of a Hierarchical NiSe 2/Carbon Nanorod: A High-Performance Nonenzymatic Glucose Sensor. ACS APPLIED MATERIALS & INTERFACES 2021; 13:22866-22873. [PMID: 33970598 DOI: 10.1021/acsami.1c04831] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
As glucose (Glu) is an essential substance for metabolism as well as a symbol to diagnose diabetes, the demand of Glu sensors has increased significantly in recent decades. In this work, a hierarchical Ni-based electrochemical enzyme-free Glu sensor, namely, NiSe2/CNR (carbon nanorod), was engineered through a facile thermal treatment using dimethylglyoxime dinickel salt with selenium (Se) powder. The prepared NiSe2/CNR not only subtly introduces a hierarchical structure with rod-like carbon nanorods and rock-like NiSe2 nanoparticles, which are extremely helpful in offering a greater catalytic activity area and more catalytic active sites, but also incorporates the Se element to increase the inherent activity. The fabricated NiSe2/CNR exhibits distinguished performance for Glu detection in alkaline electrolytes with linear ranges of 0.5-411 μM and 411 μM to 6.311 mM, high sensitivities of 3636 μA mM-1 cm-2 at low concentrations, and 2121 μA mM-1 cm-2 at high concentrations, as well as a low detection limit of 380 nM (S/N = 3). It also possesses favorable reproducibility, stability, and long-term storage capacity. The practical feasibility of NiSe2/CNR was also validated by detecting Glu in human serum. Moreover, the prepared hierarchical NiSe2/CNR is of general interest for the construction of hierarchical Ni-based sensors.
Collapse
Affiliation(s)
- Zhihao Xu
- College of Food Science and Engineering, Northwest A&F University, Yangling, 712100 Xianyang, Shaanxi, China
| | - Qinzhi Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling, 712100 Xianyang, Shaanxi, China
| | - Ruixia Li
- College of Food Science and Engineering, Northwest A&F University, Yangling, 712100 Xianyang, Shaanxi, China
| | - Hui Zhangsun
- College of Food Science and Engineering, Northwest A&F University, Yangling, 712100 Xianyang, Shaanxi, China
| | - Mengna Dong
- College of Food Science and Engineering, Northwest A&F University, Yangling, 712100 Xianyang, Shaanxi, China
| | - Li Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling, 712100 Xianyang, Shaanxi, China
| |
Collapse
|
25
|
Xie W, Gong Y, Huang S, Yu K. Phase‐Transfer Strategy toward High‐Throughput Chromatographic Detection of Pentosan Content in Wheat‐Derived Products. ChemistrySelect 2021. [DOI: 10.1002/slct.202003237] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Wei‐Qi Xie
- State Key Laboratory of Pulp and Paper Engineering South China University of Technology Guangzhou China
| | - Yi‐Xian Gong
- State Key Laboratory of Pulp and Paper Engineering South China University of Technology Guangzhou China
| | - Shi‐Wen Huang
- School of Materials Science and Engineering South China University of Technology Guangzhou China
| | - Kong‐Xian Yu
- Health Supervision Bureau of Liaoning Province Shenyang China
| |
Collapse
|
26
|
Carbon cloth-supported nanorod-like conductive Ni/Co bimetal MOF: A stable and high-performance enzyme-free electrochemical sensor for determination of glucose in serum and beverage. Food Chem 2021; 349:129202. [PMID: 33582540 DOI: 10.1016/j.foodchem.2021.129202] [Citation(s) in RCA: 75] [Impact Index Per Article: 18.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2020] [Revised: 01/19/2021] [Accepted: 01/24/2021] [Indexed: 11/21/2022]
Abstract
In this work, we propose a electrochemical enzyme-free glucose sensor by direct growth of conductive Ni/Co bimetal MOF on carbon cloth [Ni/Co(HHTP)MOF/CC] via a facile hydrothermal method. Due to excellent conductivity between Ni/Co(HHTP)MOF and CC, synergic catalytic effect of Ni and Co elements, the Ni/Co(HHTP)MOF/CC not only provides larger surface area and more effective active sites, but also boosts the charge transports and electro-catalytic performance. Under optimized conditions, the Ni/Co(HHTP)MOF/CC shows excellent activity with a linear range of 0.3 μM-2.312 mM, a low detection limit of 100 nM (S/N = 3), a fast response time of 2 s and a high sensitivity of 3250 μA mM-1 cm-2. Furthermore, the Ni/Co(HHTP)MOF/CC was successfully applied for the detection of glucose in real serum and beverages with competitive performances. This facile and cost-effective method provides a novel strategy for monitoring of glucose in biological and food samples.
Collapse
|
27
|
Electrochemical non-enzymatic glucose sensor using ionic liquid incorporated cobalt-based metal-organic framework. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105343] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
28
|
Yuan C, Qin X, Xu Y, Jing Q, Shi R, Wang Y. High sensitivity detection of H2O2 and glucose based on carbon quantum dots-catalyzed 3, 3′, 5, 5′-tetramethylbenzidine oxidation. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105365] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
29
|
Carvalho Soares L, Costa dos Santos C, Cássia Silva Luz R, Santos Damos F. Photoelectrochemical‐assisted Batch Injection Analysis (PEC‐BIA) of Glucose Exploiting Visible LED Light as an Excitation Source. ELECTROANAL 2020. [DOI: 10.1002/elan.201900436] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Affiliation(s)
- Leonardo Carvalho Soares
- Laboratory of Sensors, Devices and Analytical Methods, Department of ChemistryFederal University of Maranhão-UFMA 65080-805 São Luís MA Brazil
| | | | - Rita Cássia Silva Luz
- Laboratory of Sensors, Devices and Analytical Methods, Department of ChemistryFederal University of Maranhão-UFMA 65080-805 São Luís MA Brazil
| | - Flávio Santos Damos
- Laboratory of Sensors, Devices and Analytical Methods, Department of ChemistryFederal University of Maranhão-UFMA 65080-805 São Luís MA Brazil
| |
Collapse
|
30
|
Lu M, Deng Y, Li Y, Li T, Xu J, Chen SW, Wang J. Core-shell MOF@MOF composites for sensitive nonenzymatic glucose sensing in human serum. Anal Chim Acta 2020; 1110:35-43. [DOI: 10.1016/j.aca.2020.02.023] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2019] [Revised: 01/22/2020] [Accepted: 02/10/2020] [Indexed: 02/07/2023]
|
31
|
Well-dispersed poly(cysteine)-Ni(OH)2 nanocomposites on graphene-modified electrode surface for highly sensitive non-enzymatic glucose detection. Colloids Surf A Physicochem Eng Asp 2020. [DOI: 10.1016/j.colsurfa.2020.124549] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
32
|
High-performance non-enzymatic glucose electrochemical sensor constructed by transition nickel modified Ni@Cu-MOF. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2019.113783] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
33
|
Ge D, Yang Y, Ni X, Dong J, Qiu Q, Chu XQ, Chen X. Self-template formation of porous Co3O4 hollow nanoprisms for non-enzymatic glucose sensing in human serum. RSC Adv 2020; 10:38369-38377. [PMID: 35517558 PMCID: PMC9057297 DOI: 10.1039/d0ra06453j] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2020] [Accepted: 10/08/2020] [Indexed: 12/15/2022] Open
Abstract
A novel type of porous Co3O4 hollow nanoprism (HNP) was successfully prepared using tetragonal cobalt acetate hydroxide [Co5(OH)2(OAc)8·2H2O] as precursor by a facile solvothermal process and a subsequent calcination treatment. The morphology and structure of the Co3O4 HNPs were characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS), powder X-ray diffraction (XRD) and N2 adsorption–desorption measurements. An enzyme-free glucose sensor was constructed based on the Co3O4 HNPs, and the electrochemical performance was tested by cyclic voltammetry (CV) and chronoamperometry. The as-prepared sensor exhibited a good electrocatalytic activity for glucose oxidation at the applied potential of 0.6 V in alkaline solution, with a high sensitivity of 19.83 μA mM−1 cm−2 and a high upper limit of 30 mM, which provide the potential for direct determination of blood glucose without any dilution pretreatment. The Co3O4 HNPs had a porous and tubular structure with a large amount of accessible active sites, which enhanced the mass diffusion and accelerated the electron transfer. Moreover, the sensor also demonstrated a desirable stability, selectivity and reproducibility, and could verify the non-enzymatic analysis of glucose in real samples. Co3O4 hollow nanoprisms based non-enzymatic glucose sensor were prepared by a self-template process, exhibiting wide linear range, good selectivity and stability, which can directly monitoring blood glucose without any dilution pretreatment.![]()
Collapse
Affiliation(s)
- Danhua Ge
- College of Chemistry and Molecular Engineering
- Nanjing Tech University
- Nanjing
- PR China
| | - Yunqi Yang
- College of Chemistry and Molecular Engineering
- Nanjing Tech University
- Nanjing
- PR China
| | - Xiao Ni
- College of Chemistry and Molecular Engineering
- Nanjing Tech University
- Nanjing
- PR China
| | - Jinnan Dong
- College of Chemistry and Molecular Engineering
- Nanjing Tech University
- Nanjing
- PR China
| | - Qianying Qiu
- College of Chemistry and Molecular Engineering
- Nanjing Tech University
- Nanjing
- PR China
| | - Xue-Qiang Chu
- College of Chemistry and Molecular Engineering
- Nanjing Tech University
- Nanjing
- PR China
| | - Xiaojun Chen
- College of Chemistry and Molecular Engineering
- Nanjing Tech University
- Nanjing
- PR China
| |
Collapse
|
34
|
Metal/metal oxide@carbon composites derived from bimetallic Cu/Ni-based MOF and their electrocatalytic performance for glucose sensing. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2019.04.038] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
35
|
Chen X, Liu D, Cao G, Tang Y, Wu C. In Situ Synthesis of a Sandwich-like Graphene@ZIF-67 Heterostructure for Highly Sensitive Nonenzymatic Glucose Sensing in Human Serums. ACS APPLIED MATERIALS & INTERFACES 2019; 11:9374-9384. [PMID: 30727733 DOI: 10.1021/acsami.8b22478] [Citation(s) in RCA: 80] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Metal-organic frameworks (MOFs) have been extensively studied in recent years due to their tunable porosity, huge specific area, and controllable structure. The rich metal centers and large specific area have endowed MOFs with excellent electrochemical activity due to the multiple valence states, but the poor electronic conductivity of MOFs seriously impedes their electrocatalytic performance. Here, a polyhedral Co-based zeolite imidazole frame [Co(mim)2] n (denoted as ZIF-67, mim = 2-methylimidazole) is in situ loaded on the two sides of physically exfoliated graphene nanosheets (GSs) at room temperature, and sandwich-like GS@ZIF-67 hybrids with an ordered nanostructure are easily obtained. Compared with each individual component, the as-synthesized GS@ZIF-67 hybrids exhibit higher electrochemical activity toward glucose oxidation. Besides, the hierarchical nanocomposites also show better electrocatalytic performance compared with the same ratio of a physical mixture of GSs and ZIF-67, further demonstrating the synergistic effect between ZIF-67 and GSs. Thus, a highly sensitive nonenzymatic glucose electrochemical sensor is proposed with a linear range of 1-805.5 μM, sensitivity of 1521.1 μA Mm-1 cm-2, detection limit of 0.36 μM (S/N = 3), and excellent stability and selectivity. More importantly, the newly fabricated sensor is also successfully applied for glucose determination in human serums with satisfactory results, suggesting its promising potential toward glucose detection in real samples.
Collapse
Affiliation(s)
- Xuerong Chen
- Faculty of Materials Science & Engineering , Hubei University , Wuhan 430062 , China
- School of Laboratory Medicine , Hubei University of Chinese Medicine , Wuhan 430065 , China
| | - Dan Liu
- College of Chemistry and Chemical Engineering , Hunan Normal University , Changsha 410081 , China
| | - Guojun Cao
- Department of Hepatobiliary Surgery, Union Hospital , Tongji Medical College, Huazhong University of Science and Technology , Wuhan 430022 , China
| | - Yong Tang
- Department of Hepatobiliary Surgery, Union Hospital , Tongji Medical College, Huazhong University of Science and Technology , Wuhan 430022 , China
| | - Can Wu
- Faculty of Materials Science & Engineering , Hubei University , Wuhan 430062 , China
| |
Collapse
|
36
|
Xie WQ, Yu KX, Gong YX. Determination of iodate in iodized edible salt based on a headspace gas chromatographic technique. J Chromatogr A 2019; 1584:187-191. [DOI: 10.1016/j.chroma.2018.12.009] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2018] [Revised: 12/01/2018] [Accepted: 12/09/2018] [Indexed: 01/31/2023]
|
37
|
Luan F, Zhang S, Chen D, Wei F, Zhuang X. Ni3S2/ionic liquid-functionalized graphene as an enhanced material for the nonenzymatic detection of glucose. Microchem J 2018. [DOI: 10.1016/j.microc.2018.08.046] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|