1
|
Román-Camacho JJ, Santos-Dueñas IM, García-García I, García-Martínez T, Peinado RA, Mauricio JC. Correlating Microbial Dynamics with Key Metabolomic Profiles in Three Submerged Culture-Produced Vinegars. Foods 2024; 14:56. [PMID: 39796346 PMCID: PMC11720010 DOI: 10.3390/foods14010056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2024] [Revised: 12/19/2024] [Accepted: 12/25/2024] [Indexed: 01/13/2025] Open
Abstract
Although vinegar is a product obtained by a well-known bioprocess from a technical point of view, the complex microbiota responsible for its production and their involvement in the organoleptic profiles are not clear yet. In this work, three acetification profiles in submerged culture using both synthetic and raw materials from Andalusia (Spain) were characterized by metagenomic (16S rRNA amplicon sequencing) and metabolomic tools (stir-bar sorptive extraction with thermo-desorption coupled to gas chromatography-mass spectrometry (SBSE-TD-GC-MS) and high-performance liquid chromatography (HPLC)). A total of 29 phyla, 208 families, and many more genera were identified, comprising bacteria and archaea as well as 75 metabolites, including minor volatile compounds, amino acids, biogenic amines, and other nitrogenous compounds. It can be concluded that Komagataeibacter and Acetobacter were not only the predominant genera but also the ones that most influenced vinegar metabolite profiles by using different metabolic strategies for mutual collaboration, and together with other microbial groups, some of them were previously practically unknown in vinegar. These results can be of interest not only to deepen the basic knowledge about vinegar but also to the vinegar industry by elucidating microbial succession and the key associated metabolites.
Collapse
Affiliation(s)
- Juan J. Román-Camacho
- Department of Agricultural Chemistry, Edaphology, and Microbiology, Microbiology Area, Agrifood Campus of International Excellence ceiA3, University of Córdoba, 14014 Córdoba, Spain; (J.J.R.-C.); (T.G.-M.); (J.C.M.)
| | - Inés M. Santos-Dueñas
- Department of Inorganic Chemistry and Chemical Engineering, Chemical Engineering Area, Agrifood Campus of International Excellence ceiA3, Nano Chemistry Institute (IUNAN), University of Córdoba, 14014 Córdoba, Spain;
| | - Isidoro García-García
- Department of Inorganic Chemistry and Chemical Engineering, Chemical Engineering Area, Agrifood Campus of International Excellence ceiA3, Nano Chemistry Institute (IUNAN), University of Córdoba, 14014 Córdoba, Spain;
| | - Teresa García-Martínez
- Department of Agricultural Chemistry, Edaphology, and Microbiology, Microbiology Area, Agrifood Campus of International Excellence ceiA3, University of Córdoba, 14014 Córdoba, Spain; (J.J.R.-C.); (T.G.-M.); (J.C.M.)
| | - Rafael A. Peinado
- Department of Agricultural Chemistry, Edaphology, and Microbiology, Agricultural Chemistry Area, Agrifood Campus of International Excellence ceiA3, University of Córdoba, 14014 Córdoba, Spain;
| | - Juan C. Mauricio
- Department of Agricultural Chemistry, Edaphology, and Microbiology, Microbiology Area, Agrifood Campus of International Excellence ceiA3, University of Córdoba, 14014 Córdoba, Spain; (J.J.R.-C.); (T.G.-M.); (J.C.M.)
| |
Collapse
|
2
|
Román-Camacho JJ, Mauricio JC, Santos-Dueñas IM, García-Martínez T, García-García I. Recent advances in applying omic technologies for studying acetic acid bacteria in industrial vinegar production: A comprehensive review. Biotechnol J 2024; 19:e2300566. [PMID: 38403443 DOI: 10.1002/biot.202300566] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Revised: 12/22/2023] [Accepted: 12/28/2023] [Indexed: 02/27/2024]
Abstract
Vinegar and related bioproducts containing acetic acid as the main component are among the most appreciated fermented foodstuffs in numerous European and Asian countries because of their exceptional organoleptic and bio-healthy properties. Regarding the acetification process and obtaining of final products, there is still a lack of knowledge on fundamental aspects, especially those related to the study of biodiversity and metabolism of the present microbiota. In this context, omic technologies currently allow for the massive analysis of macromolecules and metabolites for the identification and characterization of these microorganisms working in their natural media without the need for isolation. This review approaches comprehensive research on the application of omic tools for the identification of vinegar microbiota, mainly acetic acid bacteria, with subsequent emphasis on the study of the microbial diversity, behavior, and key molecular strategies used by the predominant groups throughout acetification. The current omics tools are enabling both the finding of new vinegar microbiota members and exploring underlying strategies during the elaboration process. The species Komagataeibacter europaeus may be a model organism for present and future research in this industry; moreover, the development of integrated meta-omic analysis may facilitate the achievement of numerous of the proposed milestones. This work might provide useful guidance for the vinegar industry establishing the first steps towards the improvement of the acetification conditions and the development of new products with sensory and bio-healthy profiles adapted to the agri-food market.
Collapse
Affiliation(s)
- Juan J Román-Camacho
- Department of Agricultural Chemistry, Edaphology, and Microbiology (Microbiology area), Severo Ochoa building (C6), Agrifood Campus of International Excellence ceiA3, Universidad de Córdoba, Córdoba, Spain
| | - Juan C Mauricio
- Department of Agricultural Chemistry, Edaphology, and Microbiology (Microbiology area), Severo Ochoa building (C6), Agrifood Campus of International Excellence ceiA3, Universidad de Córdoba, Córdoba, Spain
| | - Inés María Santos-Dueñas
- Department of Inorganic Chemistry and Chemical Engineering (Chemical Engineering area), Instituto Químico Para la Energía y el Medioambiente (IQUEMA), Marie Curie building (C3), Agrifood Campus of International Excellence ceiA3, Nano Chemistry Institute (IUNAN), Universidad de Córdoba, Córdoba, Spain
| | - Teresa García-Martínez
- Department of Agricultural Chemistry, Edaphology, and Microbiology (Microbiology area), Severo Ochoa building (C6), Agrifood Campus of International Excellence ceiA3, Universidad de Córdoba, Córdoba, Spain
| | - Isidoro García-García
- Department of Inorganic Chemistry and Chemical Engineering (Chemical Engineering area), Instituto Químico Para la Energía y el Medioambiente (IQUEMA), Marie Curie building (C3), Agrifood Campus of International Excellence ceiA3, Nano Chemistry Institute (IUNAN), Universidad de Córdoba, Córdoba, Spain
| |
Collapse
|
3
|
Recent applications and chiral separation developments based on stationary phases in open tubular capillary electrochromatography (2019–2022). J Pharm Anal 2023; 13:323-339. [PMID: 37181297 PMCID: PMC10173184 DOI: 10.1016/j.jpha.2023.01.003] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2022] [Revised: 01/16/2023] [Accepted: 01/31/2023] [Indexed: 02/08/2023] Open
Abstract
Capillary electrochromatography (CEC) plays a significant role in chiral separation via the double separation principle, partition coefficient difference between the two phases, and electroosmotic flow-driven separation. Given the distinct properties of the inner wall stationary phase (SP), the separation ability of each SP differs from one another. Particularly, it provides large room for promising applications of open tubular capillary electrochromatography (OT-CEC). We divided the OT-CEC SPs developed over the past four years into six types: ionic liquids, nanoparticle materials, microporous materials, biomaterials, non-nanopolymers, and others, to mainly introduce their characteristics in chiral drug separation. There also added a few classic SPs that occurred within ten years as supplements to enrich the features of each SP. Additionally, we discuss their applications in metabolomics, food, cosmetics, environment, and biology as analytes in addition to chiral drugs. OT-CEC plays an increasingly significant role in chiral separation and may promote the development of capillary electrophoresis (CE) combined with other instruments in recent years, such as CE with mass spectrometry (CE/MS) and CE with ultraviolet light detector (CE/UV).
Collapse
|
4
|
Sandbaumhüter FA, Aerts JT, Theurillat R, Andrén PE, Thormann W, Jansson ET. Enantioselective CE-MS analysis of ketamine metabolites in urine. Electrophoresis 2023; 44:125-134. [PMID: 36398998 PMCID: PMC10108174 DOI: 10.1002/elps.202200175] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 11/16/2022] [Accepted: 11/17/2022] [Indexed: 11/21/2022]
Abstract
The chiral drug ketamine has long-lasting antidepressant effects with a fast onset and is also suitable to treat patients with therapy-resistant depression. The metabolite hydroxynorketamine (HNK) plays an important role in the antidepressant mechanism of action. Hydroxylation at the cyclohexanone ring occurs at positions 4, 5, and 6 and produces a total of 12 stereoisomers. Among those, the four 6HNK stereoisomers have the strongest antidepressant effects. Capillary electrophoresis with highly sulfated γ-cyclodextrin (CD) as a chiral selector in combination with mass spectrometry (MS) was used to develop a method for the enantioselective analysis of HNK stereoisomers with a special focus on the 6HNK stereoisomers. The partial filling approach was applied in order to avoid contamination of the MS with the chiral selector. Concentration of the chiral selector and the length of the separation zone were optimized. With 5% highly sulfated γ-CD in 20 mM ammonium formate with 10% formic acid and a 75% filling the four 6HNK stereoisomers could be separated with a resolution between 0.79 and 3.17. The method was applied to analyze fractionated equine urine collected after a ketamine infusion and to screen the fractions as well as unfractionated urine for the parent drug ketamine and other metabolites, including norketamine and dehydronorketamine.
Collapse
Affiliation(s)
| | - Jordan T Aerts
- Department of Pharmaceutical Biosciences, Uppsala University, Uppsala, Sweden
| | - Regula Theurillat
- Clinical Pharmacology Laboratory, Institute for Infectious Diseases, University of Bern, Bern, Switzerland
| | - Per E Andrén
- Department of Pharmaceutical Biosciences, Uppsala University, Uppsala, Sweden.,Science for Life Laboratory, Spatial Mass Spectrometry, Uppsala University, Uppsala, Sweden
| | - Wolfgang Thormann
- Clinical Pharmacology Laboratory, Institute for Infectious Diseases, University of Bern, Bern, Switzerland
| | - Erik T Jansson
- Department of Pharmaceutical Biosciences, Uppsala University, Uppsala, Sweden
| |
Collapse
|
5
|
Wu F, Wu X, Chi C, Ding CF. Simultaneous Differentiation of C═C Position Isomerism in Fatty Acids through Ion Mobility and Theoretical Calculations. Anal Chem 2022; 94:12213-12220. [PMID: 36008361 DOI: 10.1021/acs.analchem.2c02706] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Fatty acids play a pivotal role in biological processes and have many isomers, particularly at the C═C position, that influence their biological function. Distinguishing between isomers is crucial to investigating their role in health and disease. However, separating the isomers poses a significant analytical challenge. In this study, we developed a simple and rapid strategy combining ion mobility spectrometry and theoretical chemical calculations to differentiate and quantify the C═C positional isomers in 2-/3-butenoic acid (BA), 2-/3-/4-pentenoic acid (PA), and 2-/3-/5-hexenoic acid (HA). C═C positional isomerism was mobility-differentiated by simple complexation with crown ethers (12C4, 15C5, and 18C6) and divalent metal ions (Mg2+, Ca2+, Mn2+, Fe2+, Co2+, Ni2+, Zn2+, Sr2+, and Ba2+), that is, converting C═C positional isomers with small structural differences into complexes with large structural differences through the interaction with metal ions and crown ethers. Metallized isomers were formed but could not be differentiated due to their complex and overlapping extracted ion mobiliograms (EIMs). Binary crown ether-isomer complexes were not observed, indicating that C═C positional isomers could not be separated by simple mixing with crown ethers. However, significant EIM differences were obtained for the formed ternary complexes, allowing baseline separation for the isomers. Notably, all crown ethers and metal ions have a separation effect with the isomers, with a calculated separation resolution (Rp-p) of 0.07-2.44. Theoretical chemical calculations were performed to provide in-depth structural information for the complexes and explain the separation principle. Theoretical conformational space showed that the divalent metal ions act as a bridge connecting the crown ether and the isomer. Additionally, the ternary complex becomes more compact as the distance between C═C and -COOH increases. Theoretical results can reflect the features of mobility experiments, with relative errors between the experiment collision cross-section (CCS) and theoretical CCS of no more than ±8.06%. This method was also evaluated in terms of quantification, accuracy, and precision repeatability. Overall, this study establishes that the crown ether-metal ion pair can function as a robust unit for differentiating C═C positional isomerism.
Collapse
Affiliation(s)
- Fangling Wu
- Key Laboratory of Advanced Mass Spectrometry and Molecular Analysis of Zhejiang Province, Institute of Mass Spectrometry, School of Material Science and Chemical Engineering, Ningbo University, Ningbo, Zhejiang 315211, China
| | - Xishi Wu
- Engineering Laboratory of Advanced Energy Materials, Ningbo Institute of Materials Technology & Engineering, Chinese Academy of Sciences, Ningo, Zhejiang 315201, China
| | - Chaoxian Chi
- Key Laboratory of Advanced Mass Spectrometry and Molecular Analysis of Zhejiang Province, Institute of Mass Spectrometry, School of Material Science and Chemical Engineering, Ningbo University, Ningbo, Zhejiang 315211, China
| | - Chuan-Fan Ding
- Key Laboratory of Advanced Mass Spectrometry and Molecular Analysis of Zhejiang Province, Institute of Mass Spectrometry, School of Material Science and Chemical Engineering, Ningbo University, Ningbo, Zhejiang 315211, China
| |
Collapse
|
6
|
Liu Y, Xu F, Wu F, Wang H, Liang Z, Ding CF. Chiral distinction of phenyl-substituted ethanediol enantiomers by measuring the ion mobility of their ternary complexes. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107389] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
7
|
Shamsi SA, Akter F. Capillary Electrophoresis Mass Spectrometry: Developments and Applications for Enantioselective Analysis from 2011-2020. Molecules 2022; 27:4126. [PMID: 35807372 PMCID: PMC9268241 DOI: 10.3390/molecules27134126] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Revised: 06/15/2022] [Accepted: 06/21/2022] [Indexed: 12/01/2022] Open
Abstract
It is now more than 25 years since the first report of enantioselective analysis by capillary electrophoresis-mass spectrometry (CE-MS) appeared. This article reviews the power of chiral CE-MS in resolving issues on the use of chiral selector incompatibility with MS and poor detectability encountered for chiral compounds by UV detection. The review begins with the general principles, requirements, and critical aspects of chiral CE-MS instrumentation. Next, the review provides a survey of MS-compatible chiral selectors (CSs) reported during the past decade, and the key achievements encountered in the time period using these CSs. Within the context of the strategies used to combine CE and MS, special attention is paid to the approaches that feature partial filling technique, counter-migration techniques, and direct use of CS, such as molecular micelles. In particular, the development and application of moving and fixed CS for EKC-MS, MEKC-MS, and CEC-MS demonstrate how various chiral compounds analyses were solved in a simple and elegant way during the 2010-2020 review period. The most noteworthy applications in the determination of chiral compounds are critically examined. The operating analytical conditions are detailed in the Tables, and the authors provide commentary on future trends of chiral separations by CE-MS.
Collapse
Affiliation(s)
- Shahab A. Shamsi
- Department of Chemistry, Georgia State University, Atlanta, GA 30303, USA;
| | | |
Collapse
|
8
|
Wang A, Liu K, Tian M, Yang L. Open Tubular Capillary Electrochromatography-Mass Spectrometry for Analysis of Underivatized Amino Acid Enantiomers with a Porous Layer-Gold Nanoparticle-Modified Chiral Column. Anal Chem 2022; 94:9252-9260. [PMID: 35713648 DOI: 10.1021/acs.analchem.2c00233] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
By developing a novel chiral column, we integrate open tubular capillary electrochromatography into sheathless mass spectrometry (MS) for efficient analysis of underivatized amino acid enantiomers. The chiral column is easily fabricated by modifying the inner surface of a capillary with a three-dimensional porous layer (PL, thickness ∼ 90 nm, pore size ∼ 30 nm) and gold nanoparticles and by introducing a chiral selector, thiol β-cyclodextrin (SH-β-CD), onto the modified surface via Au-S bonds. This approach greatly enhances the specific surface area and thus the ratio of the stationary phase to mobile phase and interaction between the stationary phase and analytes. The proposed PLOT@Au@CD column is coupled to the sheathless CE-ESI-MS system for chiral analysis of amino acid enantiomers. No derivatization of amino acids is required for chiral analysis, and baseline separation of a total of 15 pairs of amino acid enantiomers is achieved within 17 min with high column efficiencies of 5.60 × 104 to 1.82 × 106 N/m, high resolutions of 1.51-10.0, and low limits of detection between 0.02 and 0.09 μg/mL. The separation efficiency and MS intensity are only slightly decreased over 60 runs or after usage for 15 days, showing excellent repeatability and stability of the PLOT@Au@CD column. The proposed method is successfully applied to the determination of amino acid enantiomers in vinegar samples with satisfactory accuracy. Our study provides a new approach for developing a chiral stationary phase in the chromatographic separation technique, which can be easily coupled to sensitive MS detection, thus it would be of value for various applications in the fields of chiral analysis.
Collapse
Affiliation(s)
- Anping Wang
- Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Department of Chemistry, Northeast Normal University, 5268 Renmin Street, Changchun, Jilin Province 130024, China
| | - Kexin Liu
- Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Department of Chemistry, Northeast Normal University, 5268 Renmin Street, Changchun, Jilin Province 130024, China.,Hangzhou Puyu Technology Development Co. Ltd, Hangzhou, Zhejiang Province, 311300, China
| | - Miaomiao Tian
- Institute of Chemical and Industrial Bioengineering, Jilin Engineering Normal University, 3050 Kaixuan Road, Changchun, Jilin Province, 130052, China
| | - Li Yang
- Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Department of Chemistry, Northeast Normal University, 5268 Renmin Street, Changchun, Jilin Province 130024, China
| |
Collapse
|
9
|
CHI Z, YANG L. Advances in chiral separation and analysis by capillary electrophoresis-mass spectrometry. Se Pu 2022; 40:509-519. [PMID: 35616196 PMCID: PMC9404244 DOI: 10.3724/sp.j.1123.2021.11006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
目前使用的绝大多数药物为手性化合物,它们具有相似的物理和化学性质,但药理活性不同,且常以外消旋混合物的形式存在,因此对手性化合物的分离在生物、环境、食品和医药等领域一直备受关注。与广泛使用的液相色谱-质谱(LC-MS)相比,毛细管电泳-质谱(CE-MS)作为一种新型分离分析技术,具有分离效率高、样品和试剂消耗量低、选择性高和分离模式多样化等诸多优势,已经发展成为手性分析领域中有广阔应用前景的分析方法之一。CE-MS结合了CE的高分离效率和低样品消耗以及MS的高灵敏度和强结构解析能力,在蛋白质组学和代谢组学等领域发挥了重要作用。CE杰出的手性拆分能力与MS优势的结合,亦使CE-MS成为实现手性化合物高效分离分析的完美组合。在过去的十几年里,基于不同CE-MS分离模式的高性能手性分析体系层出不穷,如电动色谱-质谱(EKC-MS)、胶束电动色谱-质谱(MEKC-MS)和毛细管电色谱-质谱(CEC-MS)等,并成功应用于医药、生物、食品和环境科学等领域的手性化合物分析。该文主要综述了2011~2021年,CE-MS在手性化合物分析领域的技术、手性选择剂(如改性环糊精和聚合物表面活性剂等)的使用以及在医药等领域应用方面的研究进展,并讨论了不同手性分析模式的局限性,为未来的CE-MS手性分离分析技术发展及应用提供借鉴。
Collapse
|
10
|
Recent Advances on Chiral Mobile Phase Additives: A Critical Review. JOURNAL OF ANALYSIS AND TESTING 2022. [DOI: 10.1007/s41664-022-00222-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
11
|
Chao H, Qiu L, Zhou X, Cui P, Wang C, Hu H, Jiang P, Shi H, Xuan Y, Wang J. Separation of ofloxacin enantiomers by CE with fluorescence detection using DNA oligonucleotides as chiral selectors. J Sep Sci 2022; 45:2699-2707. [PMID: 35544319 DOI: 10.1002/jssc.202200209] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Revised: 05/06/2022] [Accepted: 05/06/2022] [Indexed: 11/09/2022]
Abstract
This study used CE with fluorescence detection- and partial-filling mode-based method for chiral separation of ofloxacin. The DNA oligonucleotides with different base sequences were studied as potential chiral selectors including DNA tetrahedron, G-quadruplex, and G-riched double-strand DNA. Under the optimized conditions, all the DNA chiral selectors exhibited excellent chiral separation capabilities with a resolution higher than 1.5. The electrophoretic behavior of the ofloxacin enantiomer might result from the intermediate conjugate with different stabilities between chiral selectors and analytes by a combination of the hydrogen bond and spatial recognition structure. Moreover, satisfactory repeatability regarding run-to-run and interday repeatability was obtained, and all the RSD values of migration times and resolutions were below 4% (n = 6). Conclusively, both spatial structure and arrangement of the G bases potentiated the chiral separation capability of DNA for ofloxacin enantiomer. This work offered a stepping stone for enantioseparation using DNA as chiral selectors. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Hufei Chao
- School of Pharmacy, Changzhou University, Changzhou, Jiangsu, 213164, China
| | - Lin Qiu
- School of Pharmacy, Changzhou University, Changzhou, Jiangsu, 213164, China
| | - Xinpei Zhou
- School of Pharmacy, Changzhou University, Changzhou, Jiangsu, 213164, China
| | - Pengfei Cui
- School of Pharmacy, Changzhou University, Changzhou, Jiangsu, 213164, China
| | - Cheng Wang
- School of Pharmacy, Changzhou University, Changzhou, Jiangsu, 213164, China
| | - Huaanzi Hu
- School of Pharmacy, Changzhou University, Changzhou, Jiangsu, 213164, China
| | - Pengju Jiang
- School of Pharmacy, Changzhou University, Changzhou, Jiangsu, 213164, China
| | - Honglei Shi
- Wujin Hospital Affiliated with Jiangsu University, Changzhou, Jiangsu, 213017, P. R. China.,The Wujin Clinical College of Xuzhou Medical University, Changzhou, Jiangsu, 213017, P. R. China
| | - Yang Xuan
- Key Lab of Biotechnology and Bioresources Utilization of Ministry of Education, College of Life Science, Dalian Minzu University, Dalian, Liaoning, 116600, China
| | - Jianhao Wang
- School of Pharmacy, Changzhou University, Changzhou, Jiangsu, 213164, China
| |
Collapse
|
12
|
Pomeisl K, Vaňkátová P, Hamplová V. Enantioselective HPLC of aryl-substituted oxazolines as an efficient tool for determination of chiral purity of serine medicinal components. J Sep Sci 2022; 45:2217-2227. [PMID: 35460597 DOI: 10.1002/jssc.202100958] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Revised: 04/20/2022] [Accepted: 04/20/2022] [Indexed: 11/06/2022]
Abstract
A new approach for evaluation of chiral purity of serine esterification products bearing long-chain alkyl substituents was developed. The compounds were simply converted to aryl-substituted oxazolines which: (i) facilitates effective chromatographic enantioseparation and (ii) enables direct detection using ultraviolet absorption. The method employs polysaccharide-based chiral stationary phase and allows enantioseparation of highly stable oxazoline products in less than 6 minutes using simple binary mobile phase. As opposed to the previously used normal phase method the developed method was performed in the reversed-phase mode. Aside from the benefits of switching to less hazardous solvents with regards to the principles of Green Chemistry, this has also led to reduction of the analysis time. In comparison with known serine chromophores, the best enantioseparation of aryloxazoline rigid structure may be achieved only based on non-polar interactions with chiral stationary phase. In contrast, substitution of the chromophore moiety with hydroxyl substituent affected intra and intermolecular interactions that caused enantioseparation differences. Concurrently, we found a high chirality retention of (R)- and (S)-configuration oxazoline standards (≥ 99% e.e.) during introduction of ultraviolet label. The method is suitable for rapid injection of mixture containing the ultraviolet absorption marker without prior purification. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Karel Pomeisl
- Institute of Physics, Czech Academy of Sciences, Prague, Czech Republic
| | - Petra Vaňkátová
- Institute of Physics, Czech Academy of Sciences, Prague, Czech Republic.,Department of Analytical Chemistry, Faculty of Science, Charles University, Prague, Czech Republic
| | - Věra Hamplová
- Institute of Physics, Czech Academy of Sciences, Prague, Czech Republic
| |
Collapse
|
13
|
Yuan L, Liu L, Bai Y, Qin J, Chen M, Feng F. A novel ratiometric fluorescent probe for detection of l-glutamic acid based on dual-emission carbon dots. Talanta 2022; 245:123416. [PMID: 35427947 DOI: 10.1016/j.talanta.2022.123416] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2021] [Revised: 03/24/2022] [Accepted: 03/27/2022] [Indexed: 12/27/2022]
Abstract
In this article, we report for the first time the use of a dual-emission carbon dots (CDs) with orange-yellow fluorescence for the detection of l-glutamic acid (L-Glu). The CDs was synthesized through a facile strategy of one-pot hydrothermal route using o-phenylenediamine (oPD) and oxalic acid. The CDs exhibit two fluorescence emission peaks around 453 nm and 560 nm when the excitation wavelength is at 390 nm. In the existence of L-Glu the fluorescence at 560 nm was decreased, whereas the fluorescence at 453 nm was constant. The fluorescence intensity ratio at 560 nm and 453 nm (F560/F453) expressed two great linear relationships in the L-Glu concentration range from 0 to 200 μM and 200-400 μM, respectively, with a detection limit (LOD) of about 0.085 μM. In addition, it was used to analyze L-Glu in fetal bovine serum samples successfully, which recoveries were ranging from 97.07 to 103.7%. Those results demonstrate CDs can be further explored in biomedicine studies.
Collapse
Affiliation(s)
- Lin Yuan
- Shanxi Datong University, Datong 037009, PR China
| | - Lizhen Liu
- Shanxi Datong University, Datong 037009, PR China.
| | - Yunfeng Bai
- Shanxi Datong University, Datong 037009, PR China
| | - Jun Qin
- Shanxi Datong University, Datong 037009, PR China
| | - Meng Chen
- Shanxi Datong University, Datong 037009, PR China
| | - Feng Feng
- Shanxi Datong University, Datong 037009, PR China.
| |
Collapse
|
14
|
Li XL, Han Y, Huang Y, Sun X, Xiao S, Min JZ. Highly sensitive novel fluorescent chiral probe possessing (S)-2-methylproline structures for the determination of chiral amino compounds by ultra-performance liquid chromatography with fluorescence: An application in the saliva of healthy volunteer. J Chromatogr A 2021; 1661:462672. [PMID: 34896695 DOI: 10.1016/j.chroma.2021.462672] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 10/23/2021] [Accepted: 11/02/2021] [Indexed: 01/12/2023]
Abstract
We developed a novel fluorescent chiral probe, DBD-trans-2-methyl-L-proline (DBD-M-Pro), which can be used to target recognition of amino functional groups using chiral resolution. To investigate the chiral resolution efficiency, 20 chiral amino enantiomers (19 DL-amino acids and phenylethylamine) were labeled using ultra-performance liquid chromatography (UPLC) with a fluorescence (FL) system. Diastereomers were formed by the reactions of DBD-M-Pro with enantiomers of amino functional groups at 60 °C for 60 min and detected on a BEH C18 column (100 × 2.1 mm, 1.7 μm). Gradient elution of 10 mM ammonium acetate with 0.05% formic acid (FA) aqueous solution and 0.1% FA acetonitrile or 0.1% FA methanol solution was performed at an excitation wavelength (Ex) 460 nm and emission wavelength (Em) 550 nm. Each resulting derivative of D- and L- type was effectively separated. The results showed that the resolution (Rs) of 17 amino acids and phenylethylamine (PEA) in the range of 1.59-24.11, except for histidine (His) (Rs = 1.32) and serine (Ser) (Rs = 1.47), achieved completely separation. The DBD-M-Pro chiral probe has a robust chiral selectivity for D-amino acids. Furthermore, a new method for the simultaneous determination of six DL-amino acids (Pro, Val, Trp, Phe, Leu, Lys) in human saliva was developed. The proposed method showed resolution values of 1.78-16.38, and an excellent linear relationship was obtained in the range of 2.5-500 pmol (R2 ≥ 0.9990). The limit of detection (S/N = 3) ranged from 0.5 to 3.75 pmol. The intra-day and inter-day coefficient of variation (CV) were within the range of 1.75-11.73%. The average addition recoveries in saliva ranged from 95.99 to 106.97%. The methodology was used to determine the content of DL-amino acids and the D/L-amino acid ratio in the saliva of 40 healthy volunteers (15 males and 25 females), as well as evaluating the differences between men and women. Our study suggests that the DBD-M-Pro chiral probe could be an effective tool for screening potential D-amino acid biomarkers in disease.
Collapse
Affiliation(s)
- Xi-Ling Li
- Key Laboratory of Natural Medicines of the Changbai Mountain, Ministry of Education, Pharmaceutical Analysis, College of Pharmacy, Yanbian University, Yanji, Jilin 133002, China
| | - Yu Han
- Key Laboratory of Natural Medicines of the Changbai Mountain, Ministry of Education, Pharmaceutical Analysis, College of Pharmacy, Yanbian University, Yanji, Jilin 133002, China
| | - Yuan Huang
- Key Laboratory of Natural Medicines of the Changbai Mountain, Ministry of Education, Pharmaceutical Analysis, College of Pharmacy, Yanbian University, Yanji, Jilin 133002, China
| | - Xiaoqi Sun
- Key Laboratory of Natural Medicines of the Changbai Mountain, Ministry of Education, Pharmaceutical Analysis, College of Pharmacy, Yanbian University, Yanji, Jilin 133002, China
| | - Shuyun Xiao
- Key Laboratory of Natural Medicines of the Changbai Mountain, Ministry of Education, Pharmaceutical Analysis, College of Pharmacy, Yanbian University, Yanji, Jilin 133002, China
| | - Jun Zhe Min
- Key Laboratory of Natural Medicines of the Changbai Mountain, Ministry of Education, Pharmaceutical Analysis, College of Pharmacy, Yanbian University, Yanji, Jilin 133002, China.
| |
Collapse
|
15
|
IWATA N, WATABE Y, HORIE S, HAYAKAWA Y. A Novel Determination Method of Thirty-Seven<i> o</i>-Phthalaldehyde-Derivatized D/L-Amino Acids with Complementary Use of Two Chiral Thiols by High Performance Liquid Chromatography. CHROMATOGRAPHY 2021. [DOI: 10.15583/jpchrom.2021.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Affiliation(s)
- Natsuki IWATA
- Global Application Development Center, Analytical & Measuring Instruments Devision, Shimadzu Corporation
| | | | - Shinnosuke HORIE
- Global Application Development Center, Analytical & Measuring Instruments Devision, Shimadzu Corporation
| | - Yoshihiro HAYAKAWA
- Global Application Development Center, Analytical & Measuring Instruments Devision, Shimadzu Corporation
| |
Collapse
|
16
|
Twenty years of amino acid determination using capillary electrophoresis: A review. Anal Chim Acta 2021; 1174:338233. [DOI: 10.1016/j.aca.2021.338233] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 01/14/2021] [Accepted: 01/16/2021] [Indexed: 12/28/2022]
|
17
|
Abstract
Like many biological compounds, proteins are found primarily in their homochiral form. However, homochirality is not guaranteed throughout life. Determining their chiral proteinogenic sequence is a complex analytical challenge. This is because certain d-amino acids contained in proteins play a role in human health and disease. This is the case, for example, with d-Asp in elastin, β-amyloid and α-crystallin which, respectively, have an action on arteriosclerosis, Alzheimer’s disease and cataracts. Sequence-dependent and sequence-independent are the two strategies for detecting the presence and position of d-amino acids in proteins. These methods rely on enzymatic digestion by a site-specific enzyme and acid hydrolysis in a deuterium or tritium environment to limit the natural racemization of amino acids. In this review, chromatographic and electrophoretic techniques, such as LC, SFC, GC and CE, will be recently developed (2018–2020) for the enantioseparation of amino acids and peptides. For future work, the discovery and development of new chiral stationary phases and derivatization reagents could increase the resolution of chiral separations.
Collapse
|
18
|
Zhao Y, Zhu X, Jiang W, Liu H, Wang J, Sun B. Natural and Artificial Chiral-Based Systems for Separation Applications. Crit Rev Anal Chem 2021; 53:27-45. [PMID: 34152894 DOI: 10.1080/10408347.2021.1932408] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Chiral separation has attracted much attention for basic research and industrial applications in analytical chemistry. Generally, chiral separations use natural or artificial chiral-based materials as adsorbents. To improve the precision and efficiency of chiral separation, focus has shifted from natural and synthetic adsorbents to binary combinations of materials. This review specifically summarizes the significant advancements made in natural and artificial chiral adsorbents as promising candidates for diverse drug and biomolecule separation applications as well as the remaining drawbacks and challenges for research on chiral separations. The mechanisms of chiral-based recognition and separation and history and development of natural and artificial chiral-based systems are the focus of this review. Future directions in natural and artificial chiral-based systems for practical separations and other applications are also presented.
Collapse
Affiliation(s)
- Yuan Zhao
- Beijing Advanced Innovation Center for Food Nutrition and Human Health, Beijing Technology and Business University, Beijing, China.,School of Food and Health, Beijing Technology and Business University, Beijing, China
| | - Xuecheng Zhu
- Beijing Advanced Innovation Center for Food Nutrition and Human Health, Beijing Technology and Business University, Beijing, China.,School of Food and Health, Beijing Technology and Business University, Beijing, China
| | - Wei Jiang
- Beijing Advanced Innovation Center for Food Nutrition and Human Health, Beijing Technology and Business University, Beijing, China.,School of Food and Health, Beijing Technology and Business University, Beijing, China
| | - Huilin Liu
- Beijing Advanced Innovation Center for Food Nutrition and Human Health, Beijing Technology and Business University, Beijing, China.,School of Food and Health, Beijing Technology and Business University, Beijing, China
| | - Jing Wang
- Beijing Advanced Innovation Center for Food Nutrition and Human Health, Beijing Technology and Business University, Beijing, China.,School of Food and Health, Beijing Technology and Business University, Beijing, China
| | - Baoguo Sun
- Beijing Advanced Innovation Center for Food Nutrition and Human Health, Beijing Technology and Business University, Beijing, China.,School of Food and Health, Beijing Technology and Business University, Beijing, China
| |
Collapse
|
19
|
Patel VD, Shamsi SA, Sutherland K. Capillary electromigration techniques coupled to mass spectrometry: Applications to food analysis. Trends Analyt Chem 2021; 139. [DOI: 10.1016/j.trac.2021.116240] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
20
|
Investigating the position of the separation capillary and emitter tube tips in a nanoflow sheath-liquid CE-ESI-MS interface to decouple the ESI potential. Talanta 2021; 228:122212. [PMID: 33773698 DOI: 10.1016/j.talanta.2021.122212] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Revised: 02/08/2021] [Accepted: 02/09/2021] [Indexed: 12/11/2022]
Abstract
Robust decoupling of the ESI potential from the separation potential in CE-ESI-MS interfaces is very important for the high performance of the CE-ESI-MS devices and their applications for highly sensitive analyses of ionogenic compounds. In this study, we utilize a nanoflow sheath-liquid CE-ESI-MS interface composed of a quartz emitter and a separation fused silica capillary treated by etching, which are threaded to cross coupling for sheath liquid and electrode connection. Specifically, we have tested the ability of the interface to decouple the ESI potential from the separation potential at different positions of the separation capillary and ESI emitter tube tips. The interface with the separation capillary tip protruding the emitter tip by 20 μm did not provide sufficient robustness. The real ESI potential (delivered as 2.0 kV from the independent high voltage power supply HV2) ranged from 2.1 kV to 4.5 kV depending on the applied separation voltage (12.0-20.0 kV, provided by the power supply HV1) and electric conductivity of the background electrolyte (BGE) used. The interface robustness was partially improved when the capillary tip was aligned with the emitter tip. However, the complete decoupling of the spray and separation potentials was achieved only when the capillary tip was retracted 20 μm inside the emitter. In this arrangement, the ESI potential was stable and independent of both the separation potential (voltage) and the BGE conductivity. Moreover, this setting provided better sensitivity for the CE-ESI-MS analysis of selected drugs and benzylpyridinium cations than the setup with the capillary tip aligned with or protruding the emitter tip.
Collapse
|
21
|
El Deeb S, Silva CF, Junior CSN, Hanafi RS, Borges KB. Chiral Capillary Electrokinetic Chromatography: Principle and Applications, Detection and Identification, Design of Experiment, and Exploration of Chiral Recognition Using Molecular Modeling. Molecules 2021; 26:2841. [PMID: 34064769 PMCID: PMC8151978 DOI: 10.3390/molecules26102841] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Revised: 05/04/2021] [Accepted: 05/07/2021] [Indexed: 12/19/2022] Open
Abstract
This work reviews the literature of chiral capillary electrokinetic chromatography from January 2016 to March 2021. This is done to explore the state-of-the-art approach and recent developments carried out in this field. The separation principle of the technique is described and supported with simple graphical illustrations, showing migration under normal and reversed polarity modes of the separation voltage. The most relevant applications of the technique for enantioseparation of drugs and other enantiomeric molecules in different fields using chiral selectors in single, dual, or multiple systems are highlighted. Measures to improve the detection sensitivity of chiral capillary electrokinetic chromatography with UV detector are discussed, and the alternative aspects are explored, besides special emphases to hyphenation compatibility to mass spectrometry. Partial filling and counter migration techniques are described. Indirect identification of the separated enantiomers and the determination of enantiomeric migration order are mentioned. The application of Quality by Design principles to facilitate method development, optimization, and validation is presented. The elucidation and explanation of chiral recognition in molecular bases are discussed with special focus on the role of molecular modeling.
Collapse
Affiliation(s)
- Sami El Deeb
- Institute of Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, 38106 Braunschweig, Germany
| | - Camilla Fonseca Silva
- Departamento de Ciências Naturais, Campus Dom Bosco, Universidade Federal de São João del-Rei (UFSJ), Praça Dom Helvécio 74, Fábricas, São João del-Rei 36301-160, Minas Gerais, Brazil; (C.F.S.); (C.S.N.J.); (K.B.B.)
| | - Clebio Soares Nascimento Junior
- Departamento de Ciências Naturais, Campus Dom Bosco, Universidade Federal de São João del-Rei (UFSJ), Praça Dom Helvécio 74, Fábricas, São João del-Rei 36301-160, Minas Gerais, Brazil; (C.F.S.); (C.S.N.J.); (K.B.B.)
| | - Rasha Sayed Hanafi
- Department of Pharmaceutical Chemistry, Faculty of Pharmacy and Biotechnology, German University in Cairo, Cairo 11835, Egypt;
| | - Keyller Bastos Borges
- Departamento de Ciências Naturais, Campus Dom Bosco, Universidade Federal de São João del-Rei (UFSJ), Praça Dom Helvécio 74, Fábricas, São João del-Rei 36301-160, Minas Gerais, Brazil; (C.F.S.); (C.S.N.J.); (K.B.B.)
| |
Collapse
|
22
|
Pandey R, Collins M, Lu X, Sweeney SR, Chiou J, Lodi A, Tiziani S. Novel Strategy for Untargeted Chiral Metabolomics using Liquid Chromatography-High Resolution Tandem Mass Spectrometry. Anal Chem 2021; 93:5805-5814. [PMID: 33818082 DOI: 10.1021/acs.analchem.0c05325] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Stereospecific recognition of metabolites plays a significant role in the detection of potential disease biomarkers thereby providing new insights in diagnosis and prognosis. D-Hdroxy/amino acids are recognized as potential biomarkers in several metabolic disorders. Despite continuous advances in metabolomics technologies, the simultaneous measurement of different classes of enantiomeric metabolites in a single analytical run remains challenging. Here, we develop a novel strategy for untargeted chiral metabolomics of hydroxy/amine groups (-OH/-NH2) containing metabolites, including all hydroxy acids (HAs) and amino acids (AAs), by chiral derivatization coupled with liquid chromatography-high resolution tandem mass spectrometry (LC-HR-MS/MS). Diacetyl-tartaric anhydride (DATAN) was used for the simultaneous derivatization of-OH/-NH2 containing metabolites as well as the resulting diastereomers, and all the derivatized metabolites were resolved in a single analytical run. Data independent MS/MS acquisition (DIA) was applied to positively identify DATAN-labeled metabolites based on reagent specific diagnostic fragment ions. We discriminated chiral from achiral metabolites based on the reversal of elution order of D and L isomers derivatized with the enantiomeric pair (±) of DATAN in an untargeted manner. Using the developed strategy, a library of 301 standards that consisted of 214 chiral and 87 achiral metabolites were separated and detected in a single analytical run. This approach was then applied to investigate the enantioselective metabolic profile of the bone marrow (BM) and peripheral blood (PB) plasma samples from patients with acute myeloid leukemia (AML) at diagnosis and following completion of the induction phase of chemotherapeutic treatment. The sensitivity and selectivity of the developed method enabled the detection of trace levels of the D-enantiomer of HAs and AAs in primary plasma patient samples. Several of these metabolites were significantly altered in response to chemotherapy. The developed LC-HR-MS method entails a valuable step forward in chiral metabolomics.
Collapse
Affiliation(s)
- Renu Pandey
- Department of Nutritional Sciences, College of Natural Sciences, The University of Texas at Austin, Austin, Texas 78712, United States.,Dell Pediatric Research Institute, Dell Medical School, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Meghan Collins
- Department of Nutritional Sciences, College of Natural Sciences, The University of Texas at Austin, Austin, Texas 78712, United States.,Dell Pediatric Research Institute, Dell Medical School, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Xiyuan Lu
- Department of Nutritional Sciences, College of Natural Sciences, The University of Texas at Austin, Austin, Texas 78712, United States.,Dell Pediatric Research Institute, Dell Medical School, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Shannon R Sweeney
- Dell Pediatric Research Institute, Dell Medical School, The University of Texas at Austin, Austin, Texas 78712, United States.,Institute for Cell and Molecular Biology, College of Natural Sciences, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Jennifer Chiou
- Department of Nutritional Sciences, College of Natural Sciences, The University of Texas at Austin, Austin, Texas 78712, United States.,Dell Pediatric Research Institute, Dell Medical School, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Alessia Lodi
- Department of Nutritional Sciences, College of Natural Sciences, The University of Texas at Austin, Austin, Texas 78712, United States.,Dell Pediatric Research Institute, Dell Medical School, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Stefano Tiziani
- Department of Nutritional Sciences, College of Natural Sciences, The University of Texas at Austin, Austin, Texas 78712, United States.,Dell Pediatric Research Institute, Dell Medical School, The University of Texas at Austin, Austin, Texas 78712, United States.,Institute for Cell and Molecular Biology, College of Natural Sciences, The University of Texas at Austin, Austin, Texas 78712, United States.,Department of Oncology, Dell Medical School, LiveSTRONG Cancer Institutes, The University of Texas at Austin, Austin, Texas 78712, United States
| |
Collapse
|
23
|
Pérez-Alcaraz A, Borrull F, Aguilar C, Calull M, Benavente F. Enantiodetermination of R,S-3,4-methylenedioxypyrovalerone in urine samples by high pressure in-line solid-phase extraction capillary electrophoresis-mass spectrometry. Talanta 2021; 225:121994. [DOI: 10.1016/j.talanta.2020.121994] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Revised: 12/03/2020] [Accepted: 12/08/2020] [Indexed: 01/25/2023]
|
24
|
Zhang W, Ramautar R. CE-MS for metabolomics: Developments and applications in the period 2018-2020. Electrophoresis 2021; 42:381-401. [PMID: 32906195 PMCID: PMC7891659 DOI: 10.1002/elps.202000203] [Citation(s) in RCA: 67] [Impact Index Per Article: 16.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2020] [Revised: 08/30/2020] [Accepted: 09/01/2020] [Indexed: 02/06/2023]
Abstract
Capillary electrophoresis-mass spectrometry (CE-MS) is now a mature analytical technique in metabolomics, notably for the efficient profiling of polar and charged metabolites. Over the past few years, (further) progress has been made in the design of improved interfacing techniques for coupling CE to MS; also, in the development of CE-MS approaches for profiling metabolites in volume-restricted samples, and in strategies that further enhance the metabolic coverage. In this article, which is a follow-up of a previous review article covering the years 2016-2018 (Electrophoresis 2019, 40, 165-179), the main (technological) developments in CE-MS methods and strategies for metabolomics are discussed covering the literature from July 2018 to June 2020. Representative examples highlight the utility of CE-MS in the fields of biomedical, clinical, microbial, plant and food metabolomics. A complete overview of recent CE-MS-based metabolomics studies is given in a table, which provides information on sample type and pretreatment, capillary coatings, and MS detection mode. Finally, some general conclusions and perspectives are given.
Collapse
Affiliation(s)
- Wei Zhang
- Biomedical Microscale Analytics, Leiden Academic Centre for Drug ResearchLeiden UniversityLeidenThe Netherlands
| | - Rawi Ramautar
- Biomedical Microscale Analytics, Leiden Academic Centre for Drug ResearchLeiden UniversityLeidenThe Netherlands
| |
Collapse
|
25
|
Capillary Electrophoresis-Mass Spectrometry for Metabolomics: Possibilities and Perspectives. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2021; 1336:159-178. [PMID: 34628632 DOI: 10.1007/978-3-030-77252-9_9] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
Capillary electrophoresis-mass spectrometry (CE-MS) is a very useful analytical technique for the selective and highly efficient profiling of polar and charged metabolites in a wide range of biological samples. Compared to other analytical techniques, the use of CE-MS in metabolomics is relatively low as the approach is still regarded as technically challenging and not reproducible. In this chapter, the possibilities of CE-MS for metabolomics are highlighted with special emphasis on the use of recently developed interfacing designs. The utility of CE-MS for targeted and untargeted metabolomics studies is demonstrated by discussing representative and recent examples in the biomedical and clinical fields. The potential of CE-MS for large-scale and quantitative metabolomics studies is also addressed. Finally, some general conclusions and perspectives are given on this strong analytical separation technique for probing the polar metabolome.
Collapse
|
26
|
de Koster N, Clark CP, Kohler I. Past, present, and future developments in enantioselective analysis using capillary electromigration techniques. Electrophoresis 2021; 42:38-57. [PMID: 32914880 PMCID: PMC7821218 DOI: 10.1002/elps.202000151] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2020] [Revised: 08/22/2020] [Accepted: 09/08/2020] [Indexed: 12/16/2022]
Abstract
Enantioseparation of chiral products has become increasingly important in a large diversity of academic and industrial applications. The separation of chiral compounds is inherently challenging and thus requires a suitable analytical technique that can achieve high resolution and sensitivity. In this context, CE has shown remarkable results so far. Chiral CE offers an orthogonal enantioselectivity and is typically considered less costly than chromatographic techniques, since only minute amounts of chiral selectors are needed. Several CE approaches have been developed for chiral analysis, including chiral EKC and chiral CEC. Enantioseparations by EKC benefit from the wide variety of possible pseudostationary phases that can be employed. Chiral CEC, on the other hand, combines chromatographic separation principles with the bulk fluid movement of CE, benefitting from reduced band broadening as compared to pressure-driven systems. Although UV detection is conventionally used for these approaches, MS can also be considered. CE-MS represents a promising alternative due to the increased sensitivity and selectivity, enabling the chiral analysis of complex samples. The potential contamination of the MS ion source in EKC-MS can be overcome using partial-filling and counter-migration techniques. However, chiral analysis using monolithic and open-tubular CEC-MS awaits additional method validation and a dedicated commercial interface. Further efforts in chiral CE are expected toward the improvement of existing techniques, the development of novel pseudostationary phases, and establishing the use of chiral ionic liquids, molecular imprinted polymers, and metal-organic frameworks. These developments will certainly foster the adoption of CE(-MS) as a well-established technique in routine chiral analysis.
Collapse
Affiliation(s)
- Nicky de Koster
- Leiden Academic Centre for Drug Research, Division of Systems Biomedicine and PharmacologyLeiden UniversityLeidenThe Netherlands
| | - Charles P. Clark
- Leiden Academic Centre for Drug Research, Division of Systems Biomedicine and PharmacologyLeiden UniversityLeidenThe Netherlands
| | - Isabelle Kohler
- Division of BioAnalytical Chemistry, Department of Chemistry and Pharmaceutical Sciences, Amsterdam Institute for Molecular and Life SciencesVrije Universiteit AmsterdamAmsterdamThe Netherlands
| |
Collapse
|
27
|
Yan B, Huang ZA, Yahaya N, Chen DDY. Enantioselective analysis in complex matrices using capillary electrophoresis-mass spectrometry: A case study of the botanical drug Corydalis Rhizoma. J Chromatogr B Analyt Technol Biomed Life Sci 2020; 1152:122216. [PMID: 32531643 DOI: 10.1016/j.jchromb.2020.122216] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Revised: 06/02/2020] [Accepted: 06/04/2020] [Indexed: 01/13/2023]
Abstract
Enantioselective analysis is critically important in the pharmaceutical and agricultural industries. However, most of the methods reported were developed for the analysis of pure racemates acquired from chemical synthesis or purification. Direct analysis of chiral enantiomers in complex matrices has rarely been reported. This work demonstrated capillary electrophoresis-mass spectrometry (CE-MS) for the enantioselective analysis of botanical drugs for the first time, using a widely used botanical drug, Corydalis Rhizoma, as an example. The method was used for the simultaneous enantioselective analysis of dl-tetrahydropalmatine and (RS)-tetrahydroberberine (canadine) in Corydalis Rhizoma extract. Using (2-hydroxypropyl)-β-cyclodextrin as the chiral selector, a partial filling technique was used to avoid signal suppression and contamination of the MS detector. Post column organic modifier was used to assist with ionization in the flow through microvial CE-MS interface, therefore, organic solvents was not used in the background electrolyte. The completely aqueous background electrolyte contributed to better chiral separations. The CE-MS method established here can directly determine the analytes in their complex matrix without any pre-purification steps, while also offering high sensitivity and low operational costs (including sample, chiral selector and solvent). In the method validation process, good linearity (r > 0.993), sensitivity and accuracy (recoveries within 89.1-110.0%) were demonstrated. The CE-MS technique was shown to be able to provide good selectivity for the simultaneous chiral separation of multiple pairs of enantiomers in complex matrices.
Collapse
Affiliation(s)
- Binjun Yan
- College of Pharmaceutical Science, Zhejiang Chinese Medical University, Hangzhou 310053, China; Department of Chemistry, University of British Columbia, Vancouver, BC V6T 1Z1, Canada
| | - Zi-Ao Huang
- Department of Chemistry, University of British Columbia, Vancouver, BC V6T 1Z1, Canada
| | - Noorfatimah Yahaya
- Department of Chemistry, University of British Columbia, Vancouver, BC V6T 1Z1, Canada; Integrative Medicine Cluster, Advanced Medical and Dental Institute, Universiti Sains Malaysia, Penang 13200, Malaysia
| | - David Da Yong Chen
- Department of Chemistry, University of British Columbia, Vancouver, BC V6T 1Z1, Canada.
| |
Collapse
|
28
|
Carenzi G, Sacchi S, Abbondi M, Pollegioni L. Direct chromatographic methods for enantioresolution of amino acids: recent developments. Amino Acids 2020; 52:849-862. [DOI: 10.1007/s00726-020-02873-w] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Accepted: 07/05/2020] [Indexed: 12/24/2022]
|
29
|
Bernardo-Bermejo S, Sánchez-López E, Castro-Puyana M, Marina ML. Chiral capillary electrophoresis. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.115807] [Citation(s) in RCA: 66] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
30
|
Development of a cognitive function marker based on D-amino acid proportions using new chiral tandem LC-MS/MS systems. Sci Rep 2020; 10:804. [PMID: 31965028 PMCID: PMC6972825 DOI: 10.1038/s41598-020-57878-y] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2019] [Accepted: 12/27/2019] [Indexed: 12/14/2022] Open
Abstract
The incidence of dementia, a clinical symptom characterized by severe cognitive decline, is increasing worldwide. Predictive biomarkers are therefore required for early identification and management. D-amino acids in the brain contribute to cognitive function and are suggested as useful biomarkers for diagnosing dementia risk. To clarify their relationship with human cognitive decline, we developed an identification method of chiral metabolomics for detecting slight differences in chiral amino acid amounts. Chiral tandem liquid chromatography-tandem mass spectrometry systems were applied for sensitive and selective amino acid species along with chiral species determination based on anion and zwitterion exchange mechanisms. In a comprehensive health cohort (cross-sectional study), we measured blood chiral amino acid levels from 305 women (65–80 years old) classified into Control, Mild-cognitive-Impairment (MCI), and Dementia groups using the Mini-Mental State Examination. MCI exhibited higher D-Pro (D-Pro/(D-Pro + L-Pro)) proportion vs the Control group, suggesting this proportion as a useful biomarker for MCI. Biomarker accuracy was improved in combination with D-Ser proportion. Receiver operating characteristics analysis of the Control vs. MCI proportion obtained area under the curve (0.80) with 70% sensitivity and 84% specificity at the optimal cutoff value (0.30). Thus, dementia monitoring can be improved by including trace D-amino acids measurements.
Collapse
|
31
|
Establishing repeatability and ruggedness of chiral separations in micellar electrokinetic chromatography mass spectrometry: Combined use of covalently bonded capillary column and molecular micelles. J Chromatogr A 2019; 1617:460835. [PMID: 31928773 DOI: 10.1016/j.chroma.2019.460835] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2019] [Revised: 12/24/2019] [Accepted: 12/29/2019] [Indexed: 10/25/2022]
Abstract
Although micellar electrokinetic chromatography-mass spectrometry (MEKC-MS) using bare silica capillary filled with molecular micelles is an advantageous hyphenated technique for chiral analysis, it is still in the developmental stage. This is mainly because of the lower repeatability of retention time and peak area associated with the difficulty in controlling electroosmotic flow on bare silica capillaries. Besides the lower robustness and electrospray erosion of the fused-silica capillary tip, the lifetime is limited for 10-15 runs per capillary column. We have tested a new MEKC-MS method to eradicate this problem using a covalently bonded 2-acrylamido-2-methyl-1-propane-sulfonic acid (AMPS) column filled with free floating molecular micelles, polysodium N-undecenoxy carbonyl-L-leucinate (poly-L-SUCL). Simultaneous enantiomeric separations and MS/MS detection of three β-blockers [atenolol (ATEN), metoprolol (METO) and, pindolol (PINDO)] was achieved within 25 min with improved column lifetime of at least 45-50 runs. Excellent repeatability of retention time was observed for β-blockers, as evidenced by the relative standard deviation of less than 2% and 3% for intra-capillary and inter-capillary column, respectively. The linear calibration range of both β-blockers was simultaneously established using enantiomers of PINDO as an internal standard. The limit of detection and the lower limit of quantitation were 0.2 μg/mL and 0.5 μg/mL, respectively, for both ATEN and METO. Acceptable recovery of the enantiomeric content of the commercial METO tablet (98-99.5%) and ATEN tablet (89-92.5%) were obtained with adequate system suitability for the precision of peak area (≤10% RSD) under optimum conditions. The developed MEKC-MS approach was extended, which provided broader repeatibility of chiral separation to a panel of primary, secondary and tertiary amines as well as one anionic chiral compound.
Collapse
|
32
|
Fanali S, Chankvetadze B. Some thoughts about enantioseparations in capillary electrophoresis. Electrophoresis 2019; 40:2420-2437. [PMID: 31081552 DOI: 10.1002/elps.201900144] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2019] [Revised: 04/22/2019] [Accepted: 04/23/2019] [Indexed: 12/20/2022]
Abstract
In this overview the goal of the authors was to analyze from the historical perspective the reasons of success and failure of chiral capillary electrophoresis. In addition, the current trends are analyzed, unique advantages of capillary electrophoresis are highlighted and some future directions are discussed.
Collapse
Affiliation(s)
- Salvatore Fanali
- School in Natural Science and Engineering, University of Verona, Verona, Italy
| | - Bezhan Chankvetadze
- Institute of Physical and Analytical Chemistry, School of Exact and Natural Sciences, Tbilisi State University, Tbilisi, Georgia
| |
Collapse
|