1
|
Palacios-López DL, Prieto-Blanco MC, Moliner-Martínez Y, Campíns-Falcó P. Carbonyl compounds responsive 2,4-dinitrophenylhydrazine doped polydimethylsiloxane based membrane as alternative derivatizing strategy prior to in-tube solid phase microextraction coupled with capillary liquid chromatography analysis. J Chromatogr A 2025; 1740:465595. [PMID: 39700612 DOI: 10.1016/j.chroma.2024.465595] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2024] [Revised: 11/28/2024] [Accepted: 12/11/2024] [Indexed: 12/21/2024]
Abstract
In this work, a DNPH doped PDMS based membrane was developed to facilitate carbonyl compound derivatization. This membrane delivers DNPH in presence of carbonyl compounds to form hydrazones. Subsequently, the resulting hydrazones are preconcentrated, separated and detected by in-tube solid phase microextraction (IT-SPME) coupled on-line with capillary liquid chromatography (CapLC) with Uv-Vis diode array detection (DAD). The method proposed allowed the determination of the analytes up to 200 µg/L. The limits of detection were between 0.1 and 3.3 µg/L and intra-day precision and inter-day precision were lower than 7 % and 21 %. The applicability of the strategy proposed was tested in environmental (waters and PM10) and biological samples (saliva). Samples were satisfactorily analysed with recoveries in the range of 68 %-80 %. The main advantages of the proposed strategy were the increment of DNPH stability, a reduction in the solutions and wastes required for the analysis and protection of the chromatographic column minimizing the excess of DNPH, thus providing a more sustainable analytical method to estimate carbonyl compounds.
Collapse
Affiliation(s)
- Diana Lisset Palacios-López
- Grupo MINTOTA, Departament de Química Analítica, Facultat de Química, Universitat de Valencia, C/ Dr. Moliner 50, Burjassot, Valencia E46100, Spain
| | - María Carmen Prieto-Blanco
- Grupo QANAP, Instituto Universitario de Medio Ambiente (IUMA), Departamento de Química, Facultade de Ciencias, Universidade da Coruña, Zapateira, A Coruña 15071, Spain.
| | - Yolanda Moliner-Martínez
- Grupo MINTOTA, Departament de Química Analítica, Facultat de Química, Universitat de Valencia, C/ Dr. Moliner 50, Burjassot, Valencia E46100, Spain
| | - Pilar Campíns-Falcó
- Grupo MINTOTA, Departament de Química Analítica, Facultat de Química, Universitat de Valencia, C/ Dr. Moliner 50, Burjassot, Valencia E46100, Spain
| |
Collapse
|
2
|
Serb AF, Georgescu M, Onulov R, Novaconi CR, Sisu E, Bolocan A, Sandu RE. Mass-Spectrometry-Based Research of Cosmetic Ingredients. Molecules 2024; 29:1336. [PMID: 38542972 PMCID: PMC10974329 DOI: 10.3390/molecules29061336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Revised: 03/11/2024] [Accepted: 03/15/2024] [Indexed: 11/12/2024] Open
Abstract
Cosmetic products are chemical substances or mixtures used on the skin, hair, nails, teeth, and the mucous membranes of the oral cavity, whose use is intended to clean, protect, correct body odor, perfume, keep in good condition, or change appearance. The analysis of cosmetic ingredients is often challenging because of their huge complexity and their adulteration. Among various analytical tools, mass spectrometry (MS) has been largely used for compound detection, ingredient screening, quality control, detection of product authenticity, and health risk evaluation. This work is focused on the MS applications in detecting and quantification of some common cosmetic ingredients, i.e., preservatives, dyes, heavy metals, allergens, and bioconjugates in various matrices (leave-on or rinse-off cosmetic products). As a global view, MS-based analysis of bioconjugates is a narrow field, and LC- and GC/GC×GC-MS are widely used for the investigation of preservatives, dyes, and fragrances, while inductively coupled plasma (ICP)-MS is ideal for comprehensive analysis of heavy metals. Ambient ionization approaches and advanced separation methods (i.e., convergence chromatography (UPC2)) coupled to MS have been proven to be an excellent choice for the analysis of scented allergens. At the same time, the current paper explores the challenges of MS-based analysis for cosmetic safety studies.
Collapse
Affiliation(s)
- Alina Florina Serb
- Biochemistry Discipline, Biochemistry and Pharmacology Department, Victor Babes University of Medicine and Pharmacy Timisoara, Eftimie Murgu Sq. No.2, 300041 Timisoara, Romania
| | - Marius Georgescu
- Physiology Discipline, Functional Sciences Department, Victor Babes University of Medicine and Pharmacy Timisoara, Eftimie Murgu Sq. No.2, 300041 Timisoara, Romania
- Center of Immuno-Physiology and Biotechnologies (CIFBIOTEH), "Victor Babeș" University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timisoara, Romania
| | - Robert Onulov
- Faculty of Medicine, Victor Babes University of Medicine and Pharmacy Timisoara, Eftimie Murgu Sq. No.2, 300041 Timisoara, Romania
| | - Cristina Ramona Novaconi
- Faculty of Medicine, Victor Babes University of Medicine and Pharmacy Timisoara, Eftimie Murgu Sq. No.2, 300041 Timisoara, Romania
| | - Eugen Sisu
- Biochemistry Discipline, Biochemistry and Pharmacology Department, Victor Babes University of Medicine and Pharmacy Timisoara, Eftimie Murgu Sq. No.2, 300041 Timisoara, Romania
| | - Alexandru Bolocan
- Physiology Discipline, Functional Sciences Department, Victor Babes University of Medicine and Pharmacy Timisoara, Eftimie Murgu Sq. No.2, 300041 Timisoara, Romania
| | - Raluca Elena Sandu
- Department of Neurology, University of Medicine and Pharmacy of Craiova, St. Petru Rares, No. 2-4, 200433 Craiova, Romania
- Department of Biochemistry, University of Medicine and Pharmacy of Craiova, St. Petru Rares, No. 2-4, 200433 Craiova, Romania
| |
Collapse
|
3
|
Millán-Santiago J, Lucena R, Cárdenas S. Nylon 6-cellulose composite hosted in a hypodermic needle: Biofluid extraction and analysis by ambient mass spectrometry in a single device. J Pharm Anal 2023; 13:1346-1352. [PMID: 38174121 PMCID: PMC10759252 DOI: 10.1016/j.jpha.2023.06.015] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 05/28/2023] [Accepted: 06/27/2023] [Indexed: 01/05/2024] Open
Abstract
This study proposes a hypodermic needle (HN) as a sorbent holder and an electrospray (ESI) emitter, thus combining extraction and analysis in a single device. A novel nylon 6-cellulose (N6-Cel) composite sorbent is proposed to extract methadone from oral fluid samples. The cellulosic substrate provides the composite with high porosity, permitting the flow-through of the sample, while the polyamide contributes to the extraction of the analyte. The low price of the devices (considering the holder and the sorbent) contributes to the affordability of the method, and their small size allows easy transportation, opening the door to on-site extractions. Under the optimum conditions, the analyte can be determined by high-resolution ambient ionization mass spectrometry at a limit of detection (LOD) as low as 0.3 μg/L and precision (expressed as relative standard deviation, RSD) better than 9.3%. The trueness, expressed as relative recovery (RR), ranged from 90% to 109%. As high-resolution mass spectrometers are not available in many laboratories, the method was also adapted to low-resolution spectrometers. In this sense, the direct infusion of the eluates in a triple quadrupole-mass spectrometry provided an LOD of 2.2 μg/L. The RSD was better than 5.3%, and the RR ranged from 96% to 121%.
Collapse
Affiliation(s)
- Jaime Millán-Santiago
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Analytical Chemistry Department, Chemical Institute for Energy and Environment (IQUEMA), University of Cordoba, E-14071, Cordoba, Spain
| | - Rafael Lucena
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Analytical Chemistry Department, Chemical Institute for Energy and Environment (IQUEMA), University of Cordoba, E-14071, Cordoba, Spain
| | - Soledad Cárdenas
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Analytical Chemistry Department, Chemical Institute for Energy and Environment (IQUEMA), University of Cordoba, E-14071, Cordoba, Spain
| |
Collapse
|
4
|
Medina DAV, Cardoso AT, Borsatto JVB, Lanças FM. Open tubular liquid chromatography: Recent advances and future trends. J Sep Sci 2023; 46:e2300373. [PMID: 37582640 DOI: 10.1002/jssc.202300373] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Revised: 07/28/2023] [Accepted: 07/31/2023] [Indexed: 08/17/2023]
Abstract
Nano-liquid chromatography (nanoLC) is gaining significant attention as a primary analytical technique across various scientific domains. Unlike conventional high-performance LC, nanoLC utilizes columns with inner diameters (i.ds.) usually ranging from 10 to 150 μm and operates at mobile phase flow rates between 10 and 1000 nl/min, offering improved chromatographic performance and detectability. Currently, most exploration of nanoLC has focused on particle-packed columns. Although open tubular LC (OTLC) can provide superior performance, optimized OTLC columns require very narrow i.ds. (< 10 μm) and demand challenging instrumentation. At the moment, these challenges have limited the success of OTLC. Nevertheless, remarkable progress has been made in developing and utilizing OTLC systems featuring narrow columns (< 2 μm). Additionally, significant efforts have been made to explore larger columns (10-75 μm i.d), demonstrating practical applicability in many situations. Due to their perceived advantages, interest in OTLC has resurged in the last two decades. This review provides an updated outlook on the latest developments in OTLC, focusing on instrumental challenges, achievements, and advancements in column technology. Moreover, it outlines selected applications that illustrate the potential of OTLC for performing targeted and untargeted studies.
Collapse
Affiliation(s)
- Deyber Arley Vargas Medina
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, São Paulo, Brazil
| | - Alessandra Timoteo Cardoso
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, São Paulo, Brazil
| | - João Victor Basolli Borsatto
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, São Paulo, Brazil
| | - Fernando Mauro Lanças
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, São Paulo, Brazil
| |
Collapse
|
5
|
Shang Y, Meng X, Liu J, Song N, Zheng H, Han C, Ma Q. Applications of mass spectrometry in cosmetic analysis: An overview. J Chromatogr A 2023; 1705:464175. [PMID: 37406420 DOI: 10.1016/j.chroma.2023.464175] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2023] [Revised: 06/19/2023] [Accepted: 06/19/2023] [Indexed: 07/07/2023]
Abstract
Mass spectrometry (MS) is a crucial tool in cosmetic analysis. It is widely used for ingredient screening, quality control, risk monitoring, authenticity verification, and efficacy evaluation. However, due to the diversity of cosmetic products and the rapid development of MS-based analytical methods, the relevant literature needs a more systematic collation of information on this subject to unravel the true potential of MS in cosmetic analysis. Herein, an overview of the role of MS in cosmetic analysis over the past two decades is presented. The currently used sample preparation methods, ionization techniques, and types of mass analyzers are demonstrated in detail. In addition, a brief perspective on the future development of MS for cosmetic analysis is provided.
Collapse
Affiliation(s)
- Yuhan Shang
- Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| | - Xianshuang Meng
- Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| | - Juan Liu
- Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| | - Naining Song
- Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| | - Hongyan Zheng
- Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| | - Chao Han
- College of Biology and Environmental Engineering, Zhejiang Shuren University, Hangzhou 310015, China
| | - Qiang Ma
- Chinese Academy of Inspection and Quarantine, Beijing 100176, China.
| |
Collapse
|
6
|
Sartore DM, Vargas Medina DA, Bocelli MD, Jordan-Sinisterra M, Santos-Neto ÁJ, Lanças FM. Modern automated microextraction procedures for bioanalytical, environmental, and food analyses. J Sep Sci 2023; 46:e2300215. [PMID: 37232209 DOI: 10.1002/jssc.202300215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 05/02/2023] [Accepted: 05/04/2023] [Indexed: 05/27/2023]
Abstract
Sample preparation frequently is considered the most critical stage of the analytical workflow. It affects the analytical throughput and costs; moreover, it is the primary source of error and possible sample contamination. To increase efficiency, productivity, and reliability, while minimizing costs and environmental impacts, miniaturization and automation of sample preparation are necessary. Nowadays, several types of liquid-phase and solid-phase microextractions are available, as well as different automatization strategies. Thus, this review summarizes recent developments in automated microextractions coupled with liquid chromatography, from 2016 to 2022. Therefore, outstanding technologies and their main outcomes, as well as miniaturization and automation of sample preparation, are critically analyzed. Focus is given to main microextraction automation strategies, such as flow techniques, robotic systems, and column-switching approaches, reviewing their applications to the determination of small organic molecules in biological, environmental, and food/beverage samples.
Collapse
Affiliation(s)
- Douglas M Sartore
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, Brazil
| | - Deyber A Vargas Medina
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, Brazil
| | - Marcio D Bocelli
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, Brazil
| | - Marcela Jordan-Sinisterra
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, Brazil
| | - Álvaro J Santos-Neto
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, Brazil
| | - Fernando M Lanças
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, Brazil
| |
Collapse
|
7
|
Sharma N, Gupta M, Jain A, Verma KK. Tumbling vial extraction of 2,4-dinitrophenylhydrazones of carbonyl compounds in bottled water, beer and milk using naphthalene-based magnetic polyimide as sorbent and HPLC-DAD. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108573] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/27/2023]
|
8
|
Amico D, Tassone A, Pirrone N, Sprovieri F, Naccarato A. Recent applications and novel strategies for mercury determination in environmental samples using microextraction-based approaches: A review. JOURNAL OF HAZARDOUS MATERIALS 2022; 433:128823. [PMID: 35405590 DOI: 10.1016/j.jhazmat.2022.128823] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Revised: 03/25/2022] [Accepted: 03/29/2022] [Indexed: 06/14/2023]
Abstract
The growing need to monitor Hg levels in the environment to control its emissions and evaluate the effectiveness of reduction policies is driving the scientific community to focus efforts on creating analytical methods that are simpler, lower cost, more performing, and environmentally sustainable. In this context, an important contribution is provided by microextraction techniques, which have long proven to be simple, reliable, and to ensure an environmentally responsible sample preparation. This manuscript reviews the recent progress in the determination of environmental Hg using microextraction techniques. The considered studies involve all environmental compartments (i.e., air, water, soil, and biota) and have been discussed by grouping them according to the employed technique while pointing out the main advances achieved and the most important limitations. The ultimate goal is to provide an up-to-date overview of the analytical potential of microextraction techniques that can be exploited in various investigation fields and to highlight the most important knowledge gaps that should be addressed in the coming years, such as in-situ sampling, the use of natural materials, and the value of metrological support to obtain data SI-traceable and comparable.
Collapse
Affiliation(s)
- Domenico Amico
- CNR-Institute of Atmospheric Pollution Research, Rende, Italy
| | | | - Nicola Pirrone
- CNR-Institute of Atmospheric Pollution Research, Rende, Italy
| | | | - Attilio Naccarato
- CNR-Institute of Atmospheric Pollution Research, Rende, Italy; Department of Chemistry and Chemical Technologies, University of Calabria, Via P. Bucci, Rende, Italy.
| |
Collapse
|
9
|
Jirayupat C, Nagashima K, Hosomi T, Takahashi T, Samransuksamer B, Hanai Y, Nakao A, Nakatani M, Liu J, Zhang G, Tanaka W, Kanai M, Yasui T, Baba Y, Yanagida T. Breath odor-based individual authentication by an artificial olfactory sensor system and machine learning. Chem Commun (Camb) 2022; 58:6377-6380. [DOI: 10.1039/d1cc06384g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The potential feasibility of breath odor sensing-based individual authentication was demonstrated by a 16-channel chemiresistive sensor array and machine learning.
Collapse
Affiliation(s)
- Chaiyanut Jirayupat
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
- Interdisciplinary Graduate School of Engineering Sciences, Kyushu University, 6-1 Kasuga-Koen, Kasuga, Fukuoka, 816-8580, Japan
| | - Kazuki Nagashima
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
- PRESTO, Japan Science and Technology Agency, 4-1-8, Honcho, Kawaguchi-Shi, Saitama 332-0012, Japan
| | - Takuro Hosomi
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
- PRESTO, Japan Science and Technology Agency, 4-1-8, Honcho, Kawaguchi-Shi, Saitama 332-0012, Japan
| | - Tsunaki Takahashi
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
- PRESTO, Japan Science and Technology Agency, 4-1-8, Honcho, Kawaguchi-Shi, Saitama 332-0012, Japan
| | - Benjarong Samransuksamer
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | - Yosuke Hanai
- Panasonic Corporation, Industry Company, Sensing Solutions Development Center, Kadoma 1006, Kadoma, Osaka 571-8506, Japan
| | - Atsuo Nakao
- Panasonic Corporation, Industry Company, Sensing Solutions Development Center, Kadoma 1006, Kadoma, Osaka 571-8506, Japan
| | - Masaya Nakatani
- Panasonic Corporation, Industry Company, Sensing Solutions Development Center, Kadoma 1006, Kadoma, Osaka 571-8506, Japan
| | - Jiangyang Liu
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | - Guozhu Zhang
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | - Wataru Tanaka
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | - Masaki Kanai
- Institute for Materials Chemistry and Engineering, Kyushu University, 6-1 Kasuga-Koen, Kasuga, Fukuoka 816-8580, Japan
| | - Takao Yasui
- PRESTO, Japan Science and Technology Agency, 4-1-8, Honcho, Kawaguchi-Shi, Saitama 332-0012, Japan
- Department of Biomolecular Engineering, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya, 464-8603, Japan
| | - Yoshinobu Baba
- Department of Biomolecular Engineering, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya, 464-8603, Japan
| | - Takeshi Yanagida
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
- Interdisciplinary Graduate School of Engineering Sciences, Kyushu University, 6-1 Kasuga-Koen, Kasuga, Fukuoka, 816-8580, Japan
- Institute for Materials Chemistry and Engineering, Kyushu University, 6-1 Kasuga-Koen, Kasuga, Fukuoka 816-8580, Japan
| |
Collapse
|
10
|
Chen H, Song X, Huang X. Development of magnetism-assisted in-tube solid phase microextraction of phenolic acids in fruit juices prior to high-performance liquid chromatography quantification. J Sep Sci 2021; 44:3418-3428. [PMID: 34288429 DOI: 10.1002/jssc.202100473] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2021] [Revised: 07/13/2021] [Accepted: 07/17/2021] [Indexed: 01/05/2023]
Abstract
Magnetism-assisted in-tube solid phase microextraction based on porous monolith mingled with Fe3 O4 nanoparticles was developed for capture of phenolic acids in fruit juices. First, poly (1-allyl-3-methylimidazolium bis [(trifluoro methyl) sulfonyl] imide-co-ethylene dimethacrylate) monolith embedded with Fe3 O4 nanoparticles was facile fabrication in a capillary and employed as microextraction column. Subsequently, a magnetic coil adopted to produce variable magnetic fields during extraction stage was twined on the microextraction column. The analytes contents in eluant were quantified by high performance liquid chromatogram with diode array detector. Various parameters affecting the extraction performance were inspected and optimized in detail. Results revealed that the exertion of magnetic fields in adsorption and desorption steps enhanced the extraction efficiencies of analytes from 44.9-64.0% to 78.6-87.1%. Under the optimal extraction factors, the limits of detection were between 0.012 and 0.061 μg/L, relative standard deviations for precision in terms of intra- and inter-day assay variability ranged from 1.9 to 9.8%. The introduced approach was successfully applied to simultaneously quantify the contents of five analytes in real fruit juices with satisfying fortified recoveries (80.1-116%). The obtained results well demonstrate the promising potential of the developed method in the highly sensitive quantification of trace phenolic acids in complex samples.
Collapse
Affiliation(s)
- Hexun Chen
- Fujian Key Laboratory of Coastal Pollution Prevention and Control, College of the Environment and Ecology, Xiamen University, Xiamen, 361005, P. R. China
| | - Xiaochong Song
- Fujian Key Laboratory of Coastal Pollution Prevention and Control, College of the Environment and Ecology, Xiamen University, Xiamen, 361005, P. R. China
| | - Xiaojia Huang
- Fujian Key Laboratory of Coastal Pollution Prevention and Control, College of the Environment and Ecology, Xiamen University, Xiamen, 361005, P. R. China
| |
Collapse
|
11
|
Carbonized Aramid Fiber as the Adsorbent for In-Tube Solid-Phase Microextraction to Detect Estrogens in Water Samples. J CHEM-NY 2021. [DOI: 10.1155/2021/9970518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Carbonized aramid fiber was prepared as a new type of adsorbent for in-tube solid-phase microextraction. The surface structure, chemical composition, and graphitization degree of the resulted fiber was determined and characterized by scanning electron microscopy, X-ray photoelectron spectroscopy, and Raman spectrometry. The prepared fiber was packed in a stainless-steel tube instead of the sample loop of a six-port and tested for the extraction of five environmental estrogen hormones coupled with high-performance liquid chromatography. Several parameters affecting the estrogens’ extraction including the sampling volume, sampling rate, NaCl content, and desorption time were investigated in detail. The extraction tube with carbonized aramid fiber exhibited remarkable extraction performance towards five estrogen targets. The analysis method was established, and it exhibited a wide linear range (0.5–10.0 μg/L) with good linearity (correlation coefficient ≥0.9906), low limits of detection (0.011–0.13 μg/L), and high enrichment factors (178–1335) for the five analytes. Relative standard deviations (n = 3) for intraday (≤4.8%) and interday (≤4.0%) tests indicated that the extraction material had satisfactory repeatability. Bisphenol A released from a polycarbonate (PC) bottle was quantitatively detected with a concentration of 8.3 μg/L. The relative recoveries spiked at 5 and 10 μg/L were investigated, and the results were in the range of 74.3–121% for real water samples.
Collapse
|
12
|
Magnetism-assisted in-tube solid phase microextraction for the on-line chromium speciation in environmental water and soil samples. Microchem J 2021. [DOI: 10.1016/j.microc.2021.105956] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
13
|
Safari M, Yamini Y. Application of magnetic nanomaterials in magnetic in-tube solid-phase microextraction. Talanta 2021; 221:121648. [PMID: 33076165 DOI: 10.1016/j.talanta.2020.121648] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Revised: 09/07/2020] [Accepted: 09/08/2020] [Indexed: 12/12/2022]
Abstract
Development of magnetic nanomaterials has greatly promoted the innovation of in-tube solid-phase microextraction. This review article gives an insight into recent advances in the modifications and applications of magnetic nanomaterials for in-tube solid-phase microextraction. Also, different magnetic nanomaterials which have recently been utilized as in-tube solid-phase microextraction sorbents are classified. This study shows that magnetic nanomaterials have gained significant attention owing to large specific surface area, selective absorption, and surface modification. Magnetic in-tube solid-phase microextraction has been applied for the analysis of food samples, biological, and environmental. However, for full development of magnetic in-tube SPME, effort is still needed to overcome limitations, such as mechanical stability, selectivity and low extraction efficiency. To achieve these objectives, research on magnetic in-tube SPME is mainly focused in the preparation of new extractive phases.
Collapse
Affiliation(s)
- Meysam Safari
- Department of Basic Sciences, Kermanshah University of Technology, Kermanshah, Iran
| | - Yadollah Yamini
- Department of Chemistry, Faculty of Sciences, Tarbiat Modares University, P.O. Box 14115-175, Tehran, Iran.
| |
Collapse
|
14
|
Kataoka H. In-tube solid-phase microextraction: Current trends and future perspectives. J Chromatogr A 2020; 1636:461787. [PMID: 33359971 DOI: 10.1016/j.chroma.2020.461787] [Citation(s) in RCA: 47] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Revised: 12/02/2020] [Accepted: 12/04/2020] [Indexed: 01/01/2023]
Abstract
In-tube solid-phase microextraction (IT-SPME) was developed about 24 years ago as an effective sample preparation technique using an open tubular capillary column as an extraction device. IT-SPME is useful for micro-concentration, automated sample cleanup, and rapid online analysis, and can be used to determine the analytes in complex matrices simple sample processing methods such as direct sample injection or filtration. IT-SPME is usually performed in combination with high-performance liquid chromatography using an online column switching technology, in which the entire process from sample preparation to separation to data analysis is automated using the autosampler. Furthermore, IT-SPME minimizes the use of harmful organic solvents and is simple and labor-saving, making it a sustainable and environmentally friendly green analytical technique. Various operating systems and new sorbent materials have been developed to improve its extraction efficiency by, for example, enhancing its sorption capacity and selectivity. In addition, IT-SPME methods have been widely applied in environmental analysis, food analysis and bioanalysis. This review describes the present state of IT-SPME technology and summarizes its current trends and future perspectives, including method development and strategies to improve extraction efficiency.
Collapse
Affiliation(s)
- Hiroyuki Kataoka
- School of Pharmacy, Shujitsu University, Nishigawara, Okayama 703-8516, Japan.
| |
Collapse
|
15
|
Recent advances and trends in miniaturized sample preparation techniques. J Sep Sci 2019; 43:202-225. [DOI: 10.1002/jssc.201900776] [Citation(s) in RCA: 82] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2019] [Revised: 10/16/2019] [Accepted: 10/30/2019] [Indexed: 12/16/2022]
|
16
|
Magnetism-reinforced in-tube solid phase microextraction for the online determination of trace heavy metal ions in complex samples. Anal Chim Acta 2019; 1090:82-90. [DOI: 10.1016/j.aca.2019.09.028] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2019] [Revised: 09/09/2019] [Accepted: 09/12/2019] [Indexed: 12/22/2022]
|