1
|
Changizi Kecheklou A, Afshar Mogaddam MR, Sorouraddin SM, Farajzadeh MA, Fathi AA. Thin film microextraction of apixaban from plasma based on the covalent organic framework coated on a mesh prior to liquid chromatography-tandem mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2024; 1247:124302. [PMID: 39362117 DOI: 10.1016/j.jchromb.2024.124302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2024] [Revised: 08/31/2024] [Accepted: 09/05/2024] [Indexed: 10/05/2024]
Abstract
In this research, a new covalent organic framework was synthesized and utilized as a coating in thin film microextraction for the extraction of apixaban from plasma samples. This coating was applied to the mesh modified through immersion in a HF solution. The extracted drug was then analyzed using liquid chromatography-tandem mass spectrometry. By combining the high specific surface area and selectivity of the covalent organic framework, along with integrating the innovative thin film microextraction method and a sensitive analysis system, an efficient analytical approach was achieved. The target analyte was preconcentrated and extracted by immersing of the covalent organic framework-coated mesh as an absorbent into the biological sample. Subsequently, a sonication process was conducted for a specific duration. Following this, the extracted analyte was desorbed using acetonitrile as the elution solvent. The effective parameters of the proposed technique were optimized by using "one-parameter-at-a-time" strategy and the optimal conditions were selected. By integrating the developed method notable achievements were made in the terms of low limits of detection and quantification (0.17 and 0.56 µg/L, respectively), a wide linear range (0.05-250 µg/L), intra- and inter day precisions (with relative standard deviations of ≤14 %), as well as satisfactory extraction recoveries (53 % and 54 % in plasma and deionized water, respectively). Hence, it can be concluded that the introduced technique exhibits high efficiency and reliability when applied to biological samples.
Collapse
Affiliation(s)
| | - Mohammad Reza Afshar Mogaddam
- Food and Drug Safety Research Center, Tabriz University of Medical Sciences, Tabriz, Iran; Chemistry and Chemical Engineering Department, Khazar University, 41 Mehseti Street, Baku AZ1096, Azerbaijan; Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
| | | | - Mir Ali Farajzadeh
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran; Engineering Faculty, Near East University, 99138 Nicosia, North Cyprus, Mersin 10, Turkey
| | - Ali Akbar Fathi
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
| |
Collapse
|
2
|
Sartore DM, Vargas Medina DA, Bocelli MD, Jordan-Sinisterra M, Santos-Neto ÁJ, Lanças FM. Modern automated microextraction procedures for bioanalytical, environmental, and food analyses. J Sep Sci 2023; 46:e2300215. [PMID: 37232209 DOI: 10.1002/jssc.202300215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 05/02/2023] [Accepted: 05/04/2023] [Indexed: 05/27/2023]
Abstract
Sample preparation frequently is considered the most critical stage of the analytical workflow. It affects the analytical throughput and costs; moreover, it is the primary source of error and possible sample contamination. To increase efficiency, productivity, and reliability, while minimizing costs and environmental impacts, miniaturization and automation of sample preparation are necessary. Nowadays, several types of liquid-phase and solid-phase microextractions are available, as well as different automatization strategies. Thus, this review summarizes recent developments in automated microextractions coupled with liquid chromatography, from 2016 to 2022. Therefore, outstanding technologies and their main outcomes, as well as miniaturization and automation of sample preparation, are critically analyzed. Focus is given to main microextraction automation strategies, such as flow techniques, robotic systems, and column-switching approaches, reviewing their applications to the determination of small organic molecules in biological, environmental, and food/beverage samples.
Collapse
Affiliation(s)
- Douglas M Sartore
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, Brazil
| | - Deyber A Vargas Medina
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, Brazil
| | - Marcio D Bocelli
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, Brazil
| | - Marcela Jordan-Sinisterra
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, Brazil
| | - Álvaro J Santos-Neto
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, Brazil
| | - Fernando M Lanças
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, Brazil
| |
Collapse
|
3
|
Li Z, Yang M, Shen X, Zhu H, Li B. The Preparation of Covalent Bonding COF-TpBD Coating in Arrayed Nanopores of Stainless Steel Fiber for Solid-Phase Microextraction of Polycyclic Aromatic Hydrocarbons in Water. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:1393. [PMID: 36674147 PMCID: PMC9858968 DOI: 10.3390/ijerph20021393] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 01/06/2023] [Accepted: 01/10/2023] [Indexed: 06/17/2023]
Abstract
Covalent organic framework (COF)-TpBD was grafted on the arrayed nanopores of stainless steel fiber (SSF) with (3-aminopropyl) triethoxysilane as the cross-linking agent. The prepared SSF bonded with COF-TpBD showed high thermal and chemical stability and excellent repeatability. The prepared SSF bonded with COF-TpBD was also used for the solid-phase microextraction (SPME) of seven kinds of polycyclic aromatic hydrocarbons (PAHs) in actual water samples, followed by gas chromatography with flame ionization detection (GC-FID) determination, which exhibited low limits of detection (LODs), good relative standard deviation (RSD) and high recoveries.
Collapse
Affiliation(s)
- Zihan Li
- Department of Environmental Science and Engineering, North China Electric Power University, Baoding 071066, China
- Hebei Key Lab Power Plant Flue Gas Multipollutant, Baoding 071003, China
| | - Mengqi Yang
- Department of Environmental Science and Engineering, North China Electric Power University, Baoding 071066, China
- Hebei Key Lab Power Plant Flue Gas Multipollutant, Baoding 071003, China
| | - Xuetong Shen
- Department of Environmental Science and Engineering, North China Electric Power University, Baoding 071066, China
- Hebei Key Lab Power Plant Flue Gas Multipollutant, Baoding 071003, China
| | - Hongtao Zhu
- Department of Environmental Science and Engineering, North China Electric Power University, Baoding 071066, China
- Hebei Key Lab Power Plant Flue Gas Multipollutant, Baoding 071003, China
| | - Baohui Li
- Department of Environmental Science and Engineering, North China Electric Power University, Baoding 071066, China
- Hebei Key Lab Power Plant Flue Gas Multipollutant, Baoding 071003, China
| |
Collapse
|
4
|
Simple and rapid preparation of homemade SPME PDMS fibers and their application to the analysis of personal care products in water samples. CHEMICAL PAPERS 2023. [DOI: 10.1007/s11696-022-02608-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
5
|
Wang X, Han Y, Cao J, Yan H. Headspace solid-phase-microextraction using a graphene aerogel for gas chromatography–tandem mass spectrometry quantification of polychlorinated naphthalenes in shrimp. J Chromatogr A 2022; 1672:463012. [DOI: 10.1016/j.chroma.2022.463012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Revised: 03/27/2022] [Accepted: 03/30/2022] [Indexed: 10/18/2022]
|
6
|
Evaluation of New, Sputtered Carbon SPME Fibers with a Multi-Functional Group Test Mixture. SEPARATIONS 2021. [DOI: 10.3390/separations8120228] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
We report the first fabrication of sputtered carbon, solid-phase microextraction (SPME) fibers. These fibers have competitive extraction capabilities compared with the commercial carbon wide range (CWR) SPME fiber. This report also includes a demonstration of a newly developed SPME test mix that includes 15 different compounds with a wide range of functional groups and chemical properties. The fiber fabrication process involves sputtering carbon onto fused silica fibers, and the effects of throw distance on the morphology of the carbon coatings were studied. Four different carbon coating thicknesses were evaluated, with PDMS added as a stationary phase. These fibers were characterized with multiple analytical techniques, including scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), water contact angle (WCA) goniometry, as well as headspace (HS) and direct immersion (DI)–SPME–GC–MS. The best (11.5 µm) sputtered carbon SPME fibers, with and without PDMS, were evaluated using the new evaluation mix and compared with the commercial CWR fiber and a previously sputtered/developed silicon fiber. The new probe mix helped elucidate differences among the fibers, which would have been missed by current commercial test mixes. The sputtered carbon SPME fibers showed similar functional group selectivity as commercial CWR fibers. However, the sputtered carbon fibers showed higher responses per volume compared with the commercial CWR fiber, indicating the porous morphology of the sputtered carbon has the ability to overcome large phase thickness/volume discrepancies and increase the relative recovery for various compounds.
Collapse
|
7
|
Delińska K, Rakowska PW, Kloskowski A. Porous material-based sorbent coatings in solid-phase microextraction technique: Recent trends and future perspectives. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116386] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
8
|
Assessment of polycyclic aromatic hydrocarbons and derivatives in beer using a new cold fiber-solid phase microextraction system. Food Control 2021. [DOI: 10.1016/j.foodcont.2021.108104] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
9
|
Patel DI, Roychowdhury T, Shah D, Jacobsen C, Herrington JS, Hoisington J, Myers C, Salazar BG, Walker AV, Bell DS, Linford MR. 6-Phenylhexyl silane derivatized, sputtered silicon solid phase microextraction fiber for the parts-per-trillion detection of polyaromatic hydrocarbons in water and baby formula. J Sep Sci 2021; 44:2824-2836. [PMID: 33989452 DOI: 10.1002/jssc.202100266] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Revised: 05/11/2021] [Accepted: 05/12/2021] [Indexed: 12/23/2022]
Abstract
We report the fabrication of 6-phenylhexylsilane derivatized, sputtered silicon, solid phase microextraction fibers that show parts per trillion detection limits for polyaromatic hydrocarbons, and negligible carry over and phase bleed. Their fabrication involves sputtering silicon on silica fibers under various conditions. Six different fibers were evaluated by generating three different thicknesses of sputtered silicon at two different throw distances, which altered the morphologies of the silicon surfaces. All of the fibers were coated with similar thicknesses of 6-phenylhexylsilane (ca. 2 nm). These fibers were characterized with multiple analytical techniques. The optimum fiber configuration was then used to analyze polyaromatic hydrocarbons via direct immersion, gas chromatography mass spectrometry. Our best fiber for the extraction of low molecular weight polyaromatic hydrocarbons in water had similar performance to that of a commercial fiber. However, our fiber demonstrated ca. 3 times the extraction efficiency for higher molecular weight polyaromatic hydrocarbons. In addition, it outperformed the commercial fiber by showing better linearity, repeatability, and detection limits. A method for analyzing polyaromatic hydrocarbons in baby formula was developed, which showed very good linearity (0.5-125 ppb), repeatability (2-26%), detection limits (0.12-0.81 ppb), and recoveries (103-135%). In addition, our fiber showed much less (negligible) carry over and phase bleed than the commercially available fibers.
Collapse
Affiliation(s)
- Dhananjay I Patel
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah, 84602, USA
| | - Tuhin Roychowdhury
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah, 84602, USA
| | - Dhruv Shah
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah, 84602, USA
| | - Collin Jacobsen
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah, 84602, USA
| | - Jason S Herrington
- Restek Corporation, 110 Benner Circle, Bellefonte, Pennsylvania, 16823, USA
| | - Jason Hoisington
- Restek Corporation, 110 Benner Circle, Bellefonte, Pennsylvania, 16823, USA
| | - Colton Myers
- Restek Corporation, 110 Benner Circle, Bellefonte, Pennsylvania, 16823, USA
| | - Bryan G Salazar
- Department of Chemistry and Biochemistry, University of Texas at Dallas, Richardson, Texas, 75080, USA
| | - Amy V Walker
- Department of Chemistry and Biochemistry, University of Texas at Dallas, Richardson, Texas, 75080, USA.,Department of Materials Science and Engineering, University of Texas at Dallas, Richardson, Texas, 75080, USA
| | - David S Bell
- Restek Corporation, 110 Benner Circle, Bellefonte, Pennsylvania, 16823, USA
| | - Matthew R Linford
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah, 84602, USA
| |
Collapse
|
10
|
Jalili V, Barkhordari A, Ghiasvand A. Solid-phase microextraction technique for sampling and preconcentration of polycyclic aromatic hydrocarbons: A review. Microchem J 2020. [DOI: 10.1016/j.microc.2020.104967] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|