1
|
Hemida M, Haidar Ahmad IA, Barrientos RC, Regalado EL. Computer-assisted multifactorial method development for the streamlined separation and analysis of multicomponent mixtures in (Bio)pharmaceutical settings. Anal Chim Acta 2024; 1293:342178. [PMID: 38331548 DOI: 10.1016/j.aca.2023.342178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 12/13/2023] [Accepted: 12/23/2023] [Indexed: 02/10/2024]
Abstract
The (bio)pharmaceutical industry is rapidly moving towards complex drug modalities that require a commensurate level of analytical enabling technologies that can be deployed at a fast pace. Unsystematic method development and unnecessary manual intervention remain a major barrier towards a more efficient deployment of meaningful analytical assay across emerging modalities. Digitalization and automation are key to streamline method development and enable rapid assay deployment. This review discusses the use of computer-assisted multifactorial chromatographic method development strategies for fast-paced downstream characterization and purification of biopharmaceuticals. Various chromatographic techniques such as reversed-phase liquid chromatography (RPLC), hydrophilic interaction liquid chromatography (HILIC), ion exchange chromatography (IEX), hydrophobic interaction chromatography (HIC), and supercritical fluid chromatography (SFC) are addressed and critically reviewed. The most significant parameters for retention mechanism modelling, as well as mapping the separation landscape for optimal chromatographic selectivity and resolution are also discussed. Furthermore, several computer-assisted approaches for optimization and development of chromatographic methods of therapeutics, including linear, nonlinear, and multifactorial modelling are outlined. Finally, the potential of the chromatographic modelling and computer-assisted optimization strategies are also illustrated, highlighting substantial productivity improvements, and cost savings while accelerating method development, deployment and transfer processes for therapeutic analysis in industrial settings.
Collapse
Affiliation(s)
- Mohamed Hemida
- Analytical Research and Development, MRL, Merck & Co., Inc., 126 E. Lincoln Avenue, Rahway, NJ, 07065, United States.
| | - Imad A Haidar Ahmad
- Analytical Research and Development, MRL, Merck & Co., Inc., 126 E. Lincoln Avenue, Rahway, NJ, 07065, United States.
| | - Rodell C Barrientos
- Analytical Research and Development, MRL, Merck & Co., Inc., 126 E. Lincoln Avenue, Rahway, NJ, 07065, United States
| | - Erik L Regalado
- Analytical Research and Development, MRL, Merck & Co., Inc., 126 E. Lincoln Avenue, Rahway, NJ, 07065, United States
| |
Collapse
|
2
|
Packed modulation loops to reduce band broadening in two-dimensional liquid chromatography. J Chromatogr A 2023; 1690:463802. [PMID: 36681005 DOI: 10.1016/j.chroma.2023.463802] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 01/12/2023] [Accepted: 01/13/2023] [Indexed: 01/15/2023]
Abstract
Modulation interfaces employing sample loops are applied in many hyphenated separations such as two-dimensional liquid chromatography (2D-LC). When the first-dimension effluent in 2D-LC is eluted from the modulation loop, dispersion effects occur due to differences in the laminar flow velocity of the filling and emptying flow. These effects were recently studied by Moussa et al. whom recommended the use of coiled loops to promote radial diffusion and reduce this effect. In the 1980s, Coq et al. investigated the use of packed loops, which also promote radial diffusion, in large volume injection 1D-LC. Unfortunately, this concept was never investigated in the context of 2D-LC modulation. Our work evaluates use of packed loops in 2D-LC modulation and compares them to unpacked coiled and uncoiled modulation loops. The effect of the solvents, loop volume, differences in filling and emptying rates, and loop elution direction on the elution profile was investigated. Statistical moments were used as a pragmatic tool to quantify elution profile characteristics. Decreased dispersion was observed in all cases for the packed loops compared to unpacked loops and unpacked coiled loops. In particular for larger loop volumes the dispersion was reduced significantly. Furthermore, countercurrent elution resulted in narrower elution profiles in all cases compared to concurrent elution. We found that packed modulation loops are of high interested when analytes are not refocussed in the second-dimension separation (e.g. for size-exclusion chromatography). Moreover, our work suggests that the use of packed loops may aid in prevention of loop overfilling.
Collapse
|
3
|
Wicht K, Baert M, von Doehren N, Desmet G, de Villiers A, Lynen F. Speeding up temperature-responsive × reversed-phase comprehensive liquid chromatography through the combined exploitation of temperature and flow rate gradients. J Chromatogr A 2022; 1685:463584. [DOI: 10.1016/j.chroma.2022.463584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Revised: 10/15/2022] [Accepted: 10/18/2022] [Indexed: 11/27/2022]
|
4
|
Wicht K, Baert M, Schipperges S, von Doehren N, Desmet G, Van Geem KM, de Villiers A, Lynen F. Enhanced Sensitivity in Comprehensive Liquid Chromatography: Overcoming the Dilution Problem in LC × LC via Temperature-Responsive Liquid Chromatography. Anal Chem 2022; 94:16728-16737. [DOI: 10.1021/acs.analchem.2c03300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Kristina Wicht
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000 Ghent, Belgium
| | - Mathijs Baert
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000 Ghent, Belgium
| | - Sonja Schipperges
- Agilent Technologies, Hewlett Packard Street 8, D-76337 Waldbronn, Germany
| | - Norwin von Doehren
- Agilent Technologies, Netherlands BV, NL-4330 EA Middelburg, Netherlands
| | - Gert Desmet
- Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, B-1050 Brussel, Belgium
| | - Kevin M. Van Geem
- Laboratory for Chemical Technology (LCT), Department of Materials, Textiles and Chemical Engineering, Faculty of Engineering & Architecture, Ghent University, Technologiepark 125, B-9052 Zwijnaarde, Belgium
| | - André de Villiers
- Department of Chemistry and Polymer Science, University of Stellenbosch, Private Bag X1, ZA-7602 Matieland, South Africa
| | - Frédéric Lynen
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000 Ghent, Belgium
| |
Collapse
|
5
|
den Uijl MJ, Roeland T, Bos TS, Schoenmakers PJ, van Bommel MR, Pirok BW. Assessing the feasibility of stationary-phase-assisted modulation for two-dimensional liquid-chromatography separations. J Chromatogr A 2022; 1679:463388. [DOI: 10.1016/j.chroma.2022.463388] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 07/18/2022] [Accepted: 07/21/2022] [Indexed: 02/06/2023]
|
6
|
Brau T, Pirok B, Rutan S, Stoll D. Accuracy of retention model parameters obtained from retention data in liquid chromatography. J Sep Sci 2022; 45:3241-3255. [PMID: 35304809 DOI: 10.1002/jssc.202100911] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Revised: 03/02/2022] [Accepted: 03/14/2022] [Indexed: 11/10/2022]
Abstract
In liquid chromatography (LC), it is often very useful to have an accurate model of the retention factor, k, over a wide range of isocratic elution conditions. In principle, the parameters of a retention model can be obtained by fitting either isocratic or gradient retention factor data. However, in spite of many of our own attempts to accurately predict isocratic k values using retention models trained with gradient retention data, this has not worked in our hands. In the present study we have used synthetic isocratic and gradient retention data for small molecules under reversed-phase LC conditions. This allows us to discover challenges associated with predicting isocratic k's without the confounding influences of experimental issues that are difficult to model or eliminate. The results indicate that it is not currently possible to consistently predict isocratic retention factors for small molecules with accuracies better than 10%, even when using synthetic gradient retention data. Two distinct challenges in fitting gradient retention data were identified: 1) a lack of 'uniqueness' in the parameters; and 2) an inability to find the global optimum fit in a complex fitting landscape. Working with experimental data where measurement noise is unavoidable will only make the accuracy worse. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
| | - Bob Pirok
- Gustavus Adolphus College.,Van 't Hoff Institute for Molecular Sciences
| | | | | |
Collapse
|
7
|
Wicht K, Baert M, Muller M, Bandini E, Schipperges S, von Doehren N, Desmet G, de Villiers A, Lynen F. Comprehensive two-dimensional temperature-responsive × reversed phase liquid chromatography for the analysis of wine phenolics. Talanta 2022; 236:122889. [PMID: 34635268 DOI: 10.1016/j.talanta.2021.122889] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Revised: 09/13/2021] [Accepted: 09/14/2021] [Indexed: 11/18/2022]
Abstract
Phenolic compounds are an interesting class of natural products because of their proposed contribution to health benefits of foods and beverages and as a bio-source of organic (aromatic) building blocks. Phenolic extracts from natural products are often highly complex and contain compounds covering a broad range in molecular properties. While many 1D-LC and mass spectrometric approaches have been proposed for the analysis of phenolics, this complexity inevitably leads to challenging identification and purification. New insights into the composition of phenolic extracts can be obtained through online comprehensive two-dimensional liquid chromatography (LC × LC) coupled to photodiode array and mass spectrometric detection. However, several practical hurdles must be overcome to achieve high peak capacities and to obtain robust methods with this technique. In many LC × LC configurations, refocusing of analytes at the head of the 2D column is hindered by the high eluotropic strength of the solvent transferred from the 1D to the 2D, leading to peak breakthrough or broadening. LC × LC combinations whereby a purely aqueous mobile phase is used in the 1D and RPLC is used in the 2D are unaffected by these phenomena, leading to more robust methods. In this contribution, the combination of temperature-responsive liquid chromatography (TRLC) with RPLC is used for the first time for the analysis of phenolic extracts of natural origin to illustrate the potential of this alternative combination for natural product analyses. The possibilities of the combination are investigated through analysis of wine extracts by TRLC × RPLC-DAD and TRLC × RPLC-ESI-MS.
Collapse
Affiliation(s)
- Kristina Wicht
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000, Ghent, Belgium
| | - Mathijs Baert
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000, Ghent, Belgium
| | - Magriet Muller
- Department of Chemistry and Polymer Science, University of Stellenbosch, Private Bag X1, ZA-7602, Matieland, South Africa
| | - Elena Bandini
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000, Ghent, Belgium
| | - Sonja Schipperges
- Agilent Technologies, Hewlett Packard St 8, D-76337, Waldbronn, Germany
| | - Norwin von Doehren
- Agilent Technologies, Netherlands BV, NL-4330, EA, Middelburg, Netherlands
| | - Gert Desmet
- Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, B-1050, Brussel, Belgium
| | - André de Villiers
- Department of Chemistry and Polymer Science, University of Stellenbosch, Private Bag X1, ZA-7602, Matieland, South Africa
| | - Frederic Lynen
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000, Ghent, Belgium.
| |
Collapse
|
8
|
Moussa A, Lauer T, Stoll D, Desmet G, Broeckhoven K. Modelling of analyte profiles and band broadening generated by interface loops used in multi-dimensional liquid chromatography. J Chromatogr A 2021; 1659:462578. [PMID: 34700181 DOI: 10.1016/j.chroma.2021.462578] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Revised: 09/17/2021] [Accepted: 09/21/2021] [Indexed: 11/17/2022]
Abstract
Currently, the shape and variance of the analyte band entering the second dimension column when injected from an open loop interface in two-dimensional liquid chromatography is not fully understood. This is however important as it is connected to several other variables encountered when developing 2D-LC methods, including the first dimension flow rate, the sampling (modulation) time and the loop volume. Both numerical simulation methods and experimental measurements were used to understand and quantify the dispersion occurring in open tubular interface loops. Variables included are the analyte diffusion coefficient (Dmol), loop filling and emptying rates (Ffill & Fempty), loop inner diameter or radius (Rloop) and loop volume (Vloop). For a straight loop capillary, we find that the concentration profile (as measured at the loop outlet) depends only on a single dimensionless parameter tempty*=VloopFempty·DmolRloop2 and the ratio of the filling and emptying flow rates Fempty/Ffill. A model depending only on these two parameters was developed to predict of the peak variance resulting from the filling and emptying of a straight capillary operated in the first-in-last-out (FILO) modulation mode. Comparison of the concentration profiles and the corresponding variances obtained by either numerical simulation or experiments with straight capillaries shows the results generally agree very well. When the straight capillary is replaced by a tightly coiled loop, significantly smaller (20-40%) peak variances are observed compared to straight capillaries. The magnitude of these decreases is not predicted as well by simulations, however the simulation results are still useful in this case, because they represent an upper boundary (i.e., worst-case scenario) on the predicted variance.
Collapse
Affiliation(s)
- Ali Moussa
- Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussel, Belgium
| | - Thomas Lauer
- Gustavus Adolphus College, 800 West College Avenue, Saint Peter, MN, 56082, USA
| | - Dwight Stoll
- Gustavus Adolphus College, 800 West College Avenue, Saint Peter, MN, 56082, USA
| | - Gert Desmet
- Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussel, Belgium
| | - Ken Broeckhoven
- Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussel, Belgium.
| |
Collapse
|
9
|
Pérez-Cova M, Jaumot J, Tauler R. Untangling comprehensive two-dimensional liquid chromatography data sets using regions of interest and multivariate curve resolution approaches. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116207] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
10
|
Pepermans V, Chapel S, Heinisch S, Desmet G. Detailed numerical study of the peak shapes of neutral analytes injected at high solvent strength in short reversed-phase liquid chromatography columns and comparison with experimental observations. J Chromatogr A 2021; 1643:462078. [PMID: 33780885 DOI: 10.1016/j.chroma.2021.462078] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2020] [Revised: 03/10/2021] [Accepted: 03/13/2021] [Indexed: 12/27/2022]
Abstract
We report on a numerical investigation of the different steps in the development of the spatial concentration profiles developing along the axis of a liquid chromatography column when injecting large relative volumes (>10 to 20% of column volume) of analytes dissolved in a high solvent strength solvent band as can be encountered in the second dimension (2D) column of a two-dimensional liquid chromatography (2D-LC) system. More specifically, we made a detailed study of the different retention and the axial band broadening effects leading to the double-headed peak shapes or strongly fronting peaks that can be experimentally observed under certain conditions in 2D-LC. The establishment of these intricate peak profiles is discussed in all its fine, mechanistic details. The effect of the volume of the column, the volume and the shape of the sample band, the retention properties of the analyte and the band broadening experienced by the analytes and the sample solvent are investigated. A good agreement between the simulations and the experimental observations with caffeine and methylparaben injected in acetonitrile/water (ACN/H2O) mobile phase with different injection volumes is obtained. Save the difference in dwell volume, key features of experimental and simulated chromatograms agree within a few %. The simulations are also validated against a number of simple mathematical rules of thumb that can be established to predict the occurrence of a breakthrough fraction and estimate the amount of breakthrough.
Collapse
Affiliation(s)
- Vincent Pepermans
- Department of Chemical Engineering, Vrije Universiteit Brussel, Brussels, Belgium
| | - Soraya Chapel
- Université de Lyon, Institut des Sciences Analytiques, UMR 5280, CNRS, 5 rue de la Doua, 69100, Villeurbanne, France
| | - Sabine Heinisch
- Université de Lyon, Institut des Sciences Analytiques, UMR 5280, CNRS, 5 rue de la Doua, 69100, Villeurbanne, France
| | - Gert Desmet
- Department of Chemical Engineering, Vrije Universiteit Brussel, Brussels, Belgium.
| |
Collapse
|
11
|
Simulation of elution profiles in liquid chromatography – IV: Experimental characterization and modeling of solute injection profiles from a modulation valve used in two-dimensional liquid chromatography. J Chromatogr A 2020; 1626:461373. [DOI: 10.1016/j.chroma.2020.461373] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Revised: 06/25/2020] [Accepted: 06/26/2020] [Indexed: 11/21/2022]
|