M A, George SD. A surface-engineered contact lens for tear fluid biomolecule sensing. LAB ON A CHIP 2024; 24:2327-2334. [PMID: 38563256 DOI: 10.1039/d4lc00176a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/04/2024]
Abstract
The eyes provide rich physiological information and offer diagnostic potential as a sensing site, and probing tear constituents via the wearable contact lens could be explored for healthcare monitoring. Herein, we propose a novel adhesive contrast contact lens platform that can split tear film by natural means of tear secretion and blinking. The adhesive contrast is realized by selective grafting of a lubricant onto a polydimethylsiloxane (PDMS)-based contact lens, leading to high pinning zones on a non-adhesive background. The difference in contact angle hysteresis facilitates the liquid splitting. Further, the method offers control over the droplet volume by controlling the zone dimension. The adhesive contrast contact lens is coupled with fluorescent spectroscopic as well as colorimetric techniques to realize its potential as a diagnostic platform. The adhesive contrast contact lens is exploited to detect the level of lactoferrin in tear by sensitizing split droplets with Tb3+ ions. The adhesive contrast contact lens integrated with a fluorescence spectrometer was able to detect the lactoferrin level up to a concentration of 0.25 mg mL-1. Additionally, a colorimetric detection based on the fluorescence of the lactoferrin-terbium complex is demonstrated for the measurement of lactoferrin, with a limit of detection in the physiological range up to 0.5 mg mL-1.
Collapse
Affiliation(s)
- Aravind M
- Department of Atomic and Molecular Physics, Manipal Academy of Higher Education, Manipal, India - 576104.
| | - Sajan D George
- Department of Atomic and Molecular Physics, Manipal Academy of Higher Education, Manipal, India - 576104.
- Centre for Applied Nanosciences (CAN), Manipal Academy of Higher Education, Manipal, India - 576104
| |
Collapse
|
2
|
Corwin-Buell J, Callahan D, McGrath D, Millard K, Mosehauer G, Phatak NR. Biocidal Efficacies of Contact Lens Disinfecting Solutions Against International Organization for Standardization (ISO) Compendial Organisms. Clin Ophthalmol 2024; 18:337-345. [PMID: 38332902 PMCID: PMC10849899 DOI: 10.2147/opth.s445870] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2023] [Accepted: 01/17/2024] [Indexed: 02/10/2024] Open
Abstract
Purpose This study was conducted to evaluate and compare the in vitro disinfection efficacies of six commercial lens cleaning and disinfecting products for planned replacement soft contact lenses. Methods Disinfection efficacies of five multi-purpose solutions (MPSs) and one hydrogen peroxide solution (HPS) as control were evaluated in the presence of organic soil according to the International Organization for Standardization (ISO, Geneva, Switzerland) ISO 14729 stand-alone test protocol. The five specified compendial organisms, three bacteria (Staphylococcus aureus, Pseudomonas aeruginosa, and Serratia marcescens) and two fungi (Candida albicans and Fusarium solani) were incubated with each solution under standard conditions, after which microbes were recovered and quantified. Results Each of the solutions evaluated met or exceeded the standard's primary criteria (3-log reduction of bacteria and 1-log reduction of fungi) after incubation for the manufacturer-recommended soaking time, except for COMPLETE MPS, which achieved only 0.4 ± 0.1 average log reduction for C. albicans. However, differences in efficacy between the solutions were noted. Average log reduction across all microbes for Biotrue Hydration Plus (4.6 ± 0.1) was comparable to that for CLEAR CARE PLUS HPS (4.3 ± 0.1) and greater than those for OPTI-FREE puremoist (3.6 ± 0.1), OPTI-FREE Replenish (4.0 ± 0.2), ACUVUE RevitaLens (3.9 ± 0.03), and COMPLETE MPS (3.6 ± 0.1). Biotrue Hydration Plus was especially effective at reducing the population of C. albicans (4.2 ± 0.7-log reduction). Conclusion Products marketed for planned replacement soft CL disinfection generally meet the ISO 14729 standard's primary criteria for reducing populations of compendial organisms, with larger differences between solutions noted with C. albicans.
Collapse
Affiliation(s)
| | | | | | | | - Gary Mosehauer
- Vision Care, Bausch & Lomb Incorporated, Rochester, NY, USA
| | | |
Collapse
|
3
|
Itokawa T, Yamasaki K, Suzuki T, Koh S. Advances in Contact Lens Care Solutions: PVP-I Disinfectant and HAD Wetting Agents From Japan. Eye Contact Lens 2024; 50:91-101. [PMID: 38019569 DOI: 10.1097/icl.0000000000001060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/28/2023] [Indexed: 11/30/2023]
Abstract
ABSTRACT Half of the individuals who wear contact lenses use reusable lenses that require proper care. Improper contact lens (CL) care and using inadequate disinfecting solutions can lead to lens contamination, CL-related microbial keratitis, and Acanthamoeba keratitis. Oxidative disinfecting solutions, such as hydrogen peroxide, show higher efficacy than multipurpose solutions. Povidone-iodine (PVP-I), an oxidative disinfectant used in ophthalmic surgery, has been proven to be safe and effective. The PVP-I system, a CL disinfecting solution developed in Japan, has demonstrated excellent antimicrobial and antiviral properties. Although CL discomfort does not have a risk of ocular disorders with poor visual prognosis, such as keratitis, CL discomfort can still lead to lens dropout and thus needs to be addressed. To mitigate CL discomfort, it is essential to use disinfecting solutions containing surfactants and wetting agents that improve wettability of the lens surface. A CL solution containing hyaluronic acid derivatives (HADs) as wetting agents that permanently adhere to the lens surface to improve wettability of the lens surface was developed in Japan. There is potential for HAD to be integrated into various solutions. This article reviews the efficacy of novel PVP-I-based disinfecting solution and HAD wetting agents.
Collapse
Affiliation(s)
- Takashi Itokawa
- Department of Ophthalmology (T.I., T.S.), Toho University, Tokyo, Japan; OPHTECS Corporation (K.Y.), Kobe Research Center, Kobe, Japan; Ishizuchi Eye Clinic (T.S.), Ehime, Japan; Department of Innovative Visual Science (S.K.), Osaka University Graduate School of Medicine, Osaka, Japan; and Department of Ophthalmology (S.K.), Osaka University Graduate School of Medicine, Osaka, Japan
| | | | | | | |
Collapse
|
4
|
Costa D, De Matteis V, Treso F, Montani G, Martino M, Rinaldi R, Corrado M, Cascione M. Impact of the physical properties of contact lens materials on the discomfort: role of the coefficient of friction. Colloids Surf B Biointerfaces 2024; 233:113630. [PMID: 37956592 DOI: 10.1016/j.colsurfb.2023.113630] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 10/31/2023] [Accepted: 11/01/2023] [Indexed: 11/15/2023]
Abstract
Contact Lens Discomfort (CLD) is the main cause in contact lens (CLs) discontinuation, referred in literature as drop-out phenomenon. Despite such evidence was reported in several clinical studies, a relationship between physico-chemical properties of CLs and CLD is not still totally understood. In this regard, the friction of CLs surfaces seems to be related to discomfort feeling events, probably due to an alteration of the lubricate function of the tear film after the CL placement inside the ocular environment. In the last years, many studies have been finalized to the friction measurements of CLs surface, finding conflicting data due to a lack in standardized protocol. The aim of this review is primarily to show evident relationships between CLs surface properties (i.e. wettability, tear evaporation, tear film quality, etc.) and the coefficient of friction (CoF), resulting therefore the most relevant physical quantity in the CLs characterization. In addition, we reported the most recent studies in CLs tribology, which highlight that the introduction of a standard protocol in CoF measurements is necessary to obtain reproducible results, considering the aim to evaluate in a more precise way the relationship between this material surface property and comfort in CLs users.
Collapse
Affiliation(s)
- D Costa
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy
| | - V De Matteis
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Institute for Microelectronics and Microsystems (IMM), CNR, Via Monteroni, Lecce 73100, Italy.
| | - F Treso
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Centro di Ricerca in Contattologia Avanzata, Via Arnesano, Lecce 73100, Italy
| | - G Montani
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Centro di Ricerca in Contattologia Avanzata, Via Arnesano, Lecce 73100, Italy
| | - M Martino
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Centro di Ricerca in Contattologia Avanzata, Via Arnesano, Lecce 73100, Italy
| | - R Rinaldi
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Institute for Microelectronics and Microsystems (IMM), CNR, Via Monteroni, Lecce 73100, Italy
| | - M Corrado
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy
| | - M Cascione
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Institute for Microelectronics and Microsystems (IMM), CNR, Via Monteroni, Lecce 73100, Italy; Centro di Ricerca in Contattologia Avanzata, Via Arnesano, Lecce 73100, Italy.
| |
Collapse
|
5
|
Baghban R, Talebnejad MR, Meshksar A, Heydari M, Khalili MR. Recent advancements in nanomaterial-laden contact lenses for diagnosis and treatment of glaucoma, review and update. J Nanobiotechnology 2023; 21:402. [PMID: 37919748 PMCID: PMC10621182 DOI: 10.1186/s12951-023-02166-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2023] [Accepted: 10/18/2023] [Indexed: 11/04/2023] Open
Abstract
Despite the existence of numerous eye drops in the market, most of them are not sufficiently effective because of quick clearance and the barriers within the eye. To increase the delivery of the drugs to the eye, various new formulations have been explored in recent decades. These formulations aim to enhance drug retention and penetration, while enabling sustained drug release over extended periods. One such innovative approach is the utilization of contact lenses, which were originally designed for cosmetic purposes and vision correction. Contact lenses have appeared as a promising formulation for ocular drug delivery, as they can increase the bioavailability of drugs in the eye and diminish unwanted side effects. They are specifically appropriate for treating chronic eye conditions, making them an area of interest for researchers in the field of ophthalmology. This review outlines the promising potential of nanomaterial-laden contact lenses for diagnosis and treatment of glaucoma. It classifies therapeutic approaches based on nanomaterial type, summarizes diagnostic advances, discusses improvement of contact lenses properties, covers marketing perspectives, and acknowledges the challenges of these innovative contact lenses for glaucoma management.
Collapse
Affiliation(s)
- Roghayyeh Baghban
- Poostchi Ophthalmology Research Center, Department of Ophthalmology, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Mohammad Reza Talebnejad
- Poostchi Ophthalmology Research Center, Department of Ophthalmology, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran.
| | - Aidin Meshksar
- Poostchi Ophthalmology Research Center, Department of Ophthalmology, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Mojtaba Heydari
- Poostchi Ophthalmology Research Center, Department of Ophthalmology, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Mohammad Reza Khalili
- Poostchi Ophthalmology Research Center, Department of Ophthalmology, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
| |
Collapse
|
6
|
Wan K, Mashouf J, Hall B. Comfort After Refitting Symptomatic Habitual Reusable Toric Lens Wearers with a New Daily Disposable Contact Lens for Astigmatism. Clin Ophthalmol 2023; 17:3235-3241. [PMID: 37927572 PMCID: PMC10624181 DOI: 10.2147/opth.s429237] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Accepted: 09/20/2023] [Indexed: 11/07/2023] Open
Abstract
Purpose To subjectively evaluate comfort with a daily disposable (delefilcon A for astigmatism) contact lens compared to other common weekly/monthly soft toric contact lenses in symptomatic wearers. Methods This open-label, single arm study enrolled current reusable soft toric lens wearers with minimum score of 12 on the contact lens dry eye (CLDEQ-8) questionnaire. Subjects were also administered the CLDEQ-8 after 1 replacement schedule of their optimized habitual toric lenses (2 to 4 weeks), and after 2 weeks of wear with delefilcon A toric daily disposable lenses (Dailies Total1 for Astigmatism; Alcon Vision LLC, Fort Worth, Texas). Results A total of 85 subjects completed the study. Mean total CLDEQ-8 score was 16.8 ± 8.1 for subjects refit with their optimized habitual toric lenses and 12.4 ± 7.5 for subjects refit with delefilcon A toric lenses, a difference of 4.3 ± 10.4 (p < 0.001). With delefilcon A toric lenses, 78.9% of subjects reported little to no intensity of eye discomfort, compared to 51.7% for the habitual toric lenses (p = 0.005). In addition, 77.7% of subjects reported little to no intensity of dryness for delefilcon A toric lenses, compared to 50.6% for the habitual toric lenses (p = 0.001). Conclusion The subjective comfort in symptomatic habitual reusable toric contact lens wearers was improved by refitting with delefilcon A toric lenses.
Collapse
Affiliation(s)
- Keith Wan
- Scripps Optometric Group, San Diego, CA, USA
| | - Jay Mashouf
- Scripps Optometric Group, San Diego, CA, USA
| | | |
Collapse
|
7
|
Schulze MM, Fadel D, Luensmann D, Ng A, Guthrie S, Woods J, Jones L. Evaluating the Performance of Verofilcon A Daily Disposable Contact Lenses in a Group of Heavy Digital Device Users. Clin Ophthalmol 2023; 17:3165-3176. [PMID: 37901285 PMCID: PMC10612504 DOI: 10.2147/opth.s429250] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Accepted: 10/16/2023] [Indexed: 10/31/2023] Open
Abstract
Purpose The purpose of this study was to evaluate the performance of verofilcon A daily disposable contact lenses (CL) in CL wearers who identified themselves as heavy digital device users. Patients and Methods This prospective, non-masked, open-label study enrolled CL wearers who reported ≥6 hours digital device use per day. Participants were dispensed with the verofilcon A study lenses for 14±2 days, to be worn for at least 5 days a week and 10 hours per day, while continuing their normal routine of digital device use. Participants rated the lens performance at the Day 14 visit using a 0-100 (with 100 being best) scale. Ratings were completed at lens insertion, after 6 hours of digital device use, just before CL removal and for overall experience. Participants also completed a 4-point (strongly agree/disagree, slightly agree/disagree) Likert scale-based questionnaire. Results Thirty-two participants were eligible and completed the study (27 females; age 25.8 ± 6.0 years, ranging from 19 to 40). Overall lens performance ratings at the Day 14 visit (mean ± standard deviation) for comfort, dryness, and clarity of vision were 91 ± 11, 88 ± 11, and 92 ± 9, respectively. Subjective ratings were stable throughout the day with no significant differences after insertion, after 6 hours of digital device use and before CL removal (all p>0.05). The majority of participants agreed that the study lenses performed well, provided good all-day comfort (28/32; p<0.01) and good all-day vision (29/32; p<0.01). Participants also agreed that after ≥6 hours of digital device use they were satisfied with CL comfort (27/32; p<0.01), vision (29/32; p<0.01) and that the lenses provided good performance (26/32; p<0.01). Conclusion Verofilcon A lenses were found to perform well, with high ratings for comfort, dryness and vision that remained high throughout the day, during extensive digital device use.
Collapse
Affiliation(s)
- Marc-Matthias Schulze
- Centre for Ocular Research & Education (CORE), University of Waterloo, Waterloo, ON, Canada
| | - Daddi Fadel
- Centre for Ocular Research & Education (CORE), University of Waterloo, Waterloo, ON, Canada
| | - Doerte Luensmann
- Centre for Ocular Research & Education (CORE), University of Waterloo, Waterloo, ON, Canada
| | - Alison Ng
- Centre for Ocular Research & Education (CORE), University of Waterloo, Waterloo, ON, Canada
| | - Sarah Guthrie
- Centre for Ocular Research & Education (CORE), University of Waterloo, Waterloo, ON, Canada
| | - Jill Woods
- Centre for Ocular Research & Education (CORE), University of Waterloo, Waterloo, ON, Canada
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), University of Waterloo, Waterloo, ON, Canada
| |
Collapse
|
8
|
Ishihara K, Shi X, Fukazawa K, Yamaoka T, Yao G, Wu JY. Biomimetic-Engineered Silicone Hydrogel Contact Lens Materials. ACS APPLIED BIO MATERIALS 2023; 6:3600-3616. [PMID: 37616500 PMCID: PMC10521029 DOI: 10.1021/acsabm.3c00296] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Accepted: 08/16/2023] [Indexed: 08/26/2023]
Abstract
Contact lenses are one of the most successful applications of biomaterials. The chemical structure of the polymers used in contact lenses plays an important role in determining the function of contact lenses. Different types of contact lenses have been developed based on the chemical structure of polymers. When designing contact lenses, materials scientists consider factors such as mechanical properties, processing properties, optical properties, histocompatibility, and antifouling properties, to ensure long-term wear with minimal discomfort. Advances in contact lens materials have addressed traditional issues such as oxygen permeability and biocompatibility, improving overall comfort, and duration of use. For example, silicone hydrogel contact lenses with high oxygen permeability were developed to extend the duration of use. In addition, controlling the surface properties of contact lenses in direct contact with the cornea tissue through surface polymer modification mimics the surface morphology of corneal tissue while maintaining the essential properties of the contact lens, a significant improvement for long-term use and reuse of contact lenses. This review presents the material science elements required for advanced contact lenses of the future and summarizes the chemical methods for achieving these goals.
Collapse
Affiliation(s)
- Kazuhiko Ishihara
- Division
of Materials and Manufacturing Science, Graduate School of Engineering, Osaka University, Suita, Osaka 565-0871, Japan
| | - Xinfeng Shi
- Alcon
Research, LLC, Fort Worth, Texas 76134, United States
| | - Kyoko Fukazawa
- National
Cerebral and Cardiovascular Center Research Institute, Suita, Osaka 564-8565, Japan
| | - Tetsuji Yamaoka
- National
Cerebral and Cardiovascular Center Research Institute, Suita, Osaka 564-8565, Japan
| | - George Yao
- Alcon
Research, LLC, Duluth, Georgia 30097, United States
| | | |
Collapse
|
9
|
Hernández-Martínez D, Castro Pot E, Hernández Olmos P, Guzmán Hernández EA, Cobos DS, Villa Ramírez S, Villamar Duque TE, Durán Díaz Á, Omaña-Molina M. Acanthamoeba castellanii trophozoites that survive multipurpose solutions are able to adhere to cosmetic contact lenses, increasing the risk of infection. Heliyon 2023; 9:e19599. [PMID: 37809484 PMCID: PMC10558846 DOI: 10.1016/j.heliyon.2023.e19599] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Revised: 08/14/2023] [Accepted: 08/28/2023] [Indexed: 10/10/2023] Open
Abstract
Amoebae of the genus Acanthamoeba are etiological agents of amoebic keratitis, for which up to now there is no treatment of choice and one of its main risk factors is the use of contact lenses, including cosmetic contact lenses. Recently there has been an increase in amoebic keratitis cases due to the use of cosmetic contact lenses. Therefore, having a solution for the care of lenses with an efficient disinfectant effect that prevents the adhesion of trophozoites to lenses becomes essential. This study was carried out to determine the effect of 8 multipurpose contact lenses care solutions on Acanthamoeba castellanii trophozoites viability, and the efficiency of two of them to prevent the trophozoites adherence onto two cosmetic contact lenses (Acuvue 2, approved by the US Food and Drug Administration, and Magic Eye CCL, not approved). After 3 h of interaction, only AO Sept Plus, OPTI FREE Replenish, Renu Plus, Bio True and Multiplus significantly reduced the number of viable trophozoites with respect to the control; at 6 h Renu Plus, and at 12 h Conta Soft Plus and Multiplus, maintained the inhibitory effect. Only Opti Free Pure Moist did not significantly reduce the number of viable trophozoites. Multiplus and Opti Free Pure Moist (selected for their greater and lesser antiamibic effect) significantly reduced trophozoite adherence to both lenses; however, Opti Free Pure Moist was more efficient, despite the fact that A. castellanii adhered similarly to both lenses. Our results show that in all the multipurpose solutions evaluated, hundreds of viable A. castellanii trophozoites remain after several hours of incubation. Therefore, storage of the lenses in their case with MPS maintains the potential risk of amoebic keratitis in, cosmetic contact lenses wearers. Moreover, the use of CCL, not approved by the FDA, can increase the risk factor for AK since its poor manufacture can favor the permanence of amoebae, in addition to being a risk for corneal integrity.
Collapse
Affiliation(s)
- Dolores Hernández-Martínez
- Carrera de Médico Cirujano, Facultad de Estudios Superiores Iztacala, Universidad Nacional Autónoma de México, Estado de México, Mexico
| | - Edson Castro Pot
- Carrera de Optometría, Facultad de Estudios Superiores Iztacala, Universidad Nacional Autónoma de México, Estado de México, Mexico
| | - Perla Hernández Olmos
- Carrera de Optometría, Facultad de Estudios Superiores Iztacala, Universidad Nacional Autónoma de México, Estado de México, Mexico
| | | | - David Segura Cobos
- Carrera de Médico Cirujano, Facultad de Estudios Superiores Iztacala, Universidad Nacional Autónoma de México, Estado de México, Mexico
| | - Sandra Villa Ramírez
- Carrera de Optometría, Facultad de Estudios Superiores Iztacala, Universidad Nacional Autónoma de México, Estado de México, Mexico
| | - Tomás Ernesto Villamar Duque
- Carrera de Biología, Facultad de Estudios Superiores Iztacala, Universidad Nacional Autónoma de México, Estado de México, Mexico
| | - Ángel Durán Díaz
- Carrera de Biología, Facultad de Estudios Superiores Iztacala, Universidad Nacional Autónoma de México, Estado de México, Mexico
| | - Maritza Omaña-Molina
- Carrera de Médico Cirujano, Facultad de Estudios Superiores Iztacala, Universidad Nacional Autónoma de México, Estado de México, Mexico
| |
Collapse
|
10
|
Xiao K, Song H, Chen Z, Long Q. Conjunctival microbiome changes in soft contact lens users and contact lens discomfort patients. Biomarkers 2023; 28:531-537. [PMID: 37352111 DOI: 10.1080/1354750x.2023.2229532] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Accepted: 06/17/2023] [Indexed: 06/25/2023]
Abstract
INTRODUCTION Contact lens discomfort (CLD) acts as a challenging problem, and the associated conjunctival microbiome changes were unclear. MATERIAL AND METHODS Conjunctival sac swab samples were collected from 12 eyes of nonwearers (NW), 12 eyes of asymptomatic contact lens (ACL) wearers, and 11 eyes of CLD. The V3-V4 region of the 16S rRNA gene sequencing was used to investigate differences among three groups. RESULTS No differences in alpha diversity were observed among the three groups. The beta diversity showed a distinct microbiome composition between ACL and CLD group (P = 0.018) with principal coordinate analysis. The relative abundance of Firmicutes was significantly higher in CLD (48.18%) than in ACL (13.21%) group (P = 0.018). The abundance of Bacillus in patients with ACL (0.05%) or with CLD (0.02%) were significantly lower than that in the NW (1.27%) group (P = 0.024, 0.028, respectively). Moreover, the abundance of Firmicutes was positively correlated with the OSDI scores in CLD patients (r = 0.817, P < 0. 01, Spearman). DISCUSSIONS Patients with CLD have various degrees of bacterial microbiota imbalance in the conjunctival sac, compared with NW and ACL groups. CONCLUSION Firmicutes may serve as a potential biomarker for the CLD patients.
Collapse
Affiliation(s)
- Kang Xiao
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China
| | - Hang Song
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China
| | - Zhengyu Chen
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China
| | - Qin Long
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China
| |
Collapse
|
11
|
Jones L, Efron N, Bandamwar K, Barnett M, Jacobs DS, Jalbert I, Pult H, Rhee MK, Sheardown H, Shovlin JP, Stahl U, Stanila A, Tan J, Tavazzi S, Ucakhan OO, Willcox MDP, Downie LE. TFOS Lifestyle: Impact of contact lenses on the ocular surface. Ocul Surf 2023; 29:175-219. [PMID: 37149139 DOI: 10.1016/j.jtos.2023.04.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Accepted: 04/10/2023] [Indexed: 05/08/2023]
Abstract
Several lifestyle choices made by contact lens wearers can have adverse consequences on ocular health. These include being non-adherent to contact lens care, sleeping in lenses, ill-advised purchasing options, not seeing an eyecare professional for regular aftercare visits, wearing lenses when feeling unwell, wearing lenses too soon after various forms of ophthalmic surgery, and wearing lenses when engaged in risky behaviors (e.g., when using tobacco, alcohol or recreational drugs). Those with a pre-existing compromised ocular surface may find that contact lens wear exacerbates ocular disease morbidity. Conversely, contact lenses may have various therapeutic benefits. The coronavirus disease-2019 (COVID-19) pandemic impinged upon the lifestyle of contact lens wearers, introducing challenges such as mask-associated dry eye, contact lens discomfort with increased use of digital devices, inadvertent exposure to hand sanitizers, and reduced use of lenses. Wearing contact lenses in challenging environments, such as in the presence of dust and noxious chemicals, or where there is the possibility of ocular trauma (e.g., sport or working with tools) can be problematic, although in some instances lenses can be protective. Contact lenses can be worn for sport, theatre, at high altitude, driving at night, in the military and in space, and special considerations are required when prescribing in such situations to ensure successful outcomes. A systematic review and meta-analysis, incorporated within the review, identified that the influence of lifestyle factors on soft contact lens dropout remains poorly understood, and is an area in need of further research. Overall, this report investigated lifestyle-related choices made by clinicians and contact lens wearers and discovered that when appropriate lifestyle choices are made, contact lens wear can enhance the quality of life of wearers.
Collapse
Affiliation(s)
- Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada.
| | - Nathan Efron
- School of Optometry and Vision Science, Queensland University of Technology, Kelvin Grove, Queensland, Australia
| | - Kalika Bandamwar
- Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand
| | - Melissa Barnett
- University of California, Davis Eye Center, Sacramento, CA, USA
| | - Deborah S Jacobs
- Massachusetts Eye & Ear, Harvard Medical School, Boston, MA, USA
| | - Isabelle Jalbert
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Heiko Pult
- Dr Heiko Pult Optometry & Vision Research, Weinheim, Germany
| | | | - Heather Sheardown
- Department of Chemical Engineering, McMaster University, Hamilton, Ontario, Canada
| | | | - Ulli Stahl
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada
| | | | - Jacqueline Tan
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Silvia Tavazzi
- Department of Materials Science, University of Milano-Bicocca, Milan, Italy
| | | | - Mark D P Willcox
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Laura E Downie
- Department of Optometry and Vision Sciences, The University of Melbourne, Parkville, Victoria, Australia
| |
Collapse
|
12
|
Erdinest N. Development, Progression and Management of Contact Lenses and Eye Care-Editorial Letter. Vision (Basel) 2023; 7:vision7020035. [PMID: 37218953 DOI: 10.3390/vision7020035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2023] [Accepted: 04/18/2023] [Indexed: 05/24/2023] Open
Abstract
The world of contact lenses comprises a considerable segment of the ophthalmology field [...].
Collapse
Affiliation(s)
- Nir Erdinest
- Department of Ophthalmology, Hadassah-Hebrew University Medical Center, Faculty of Medicine, Hebrew University of Jerusalem, Jerusalem 91120, Israel
| |
Collapse
|
13
|
Martínez-Pérez C, Villa-Collar C, Santodomingo-Rubido J, Shinde L, Thite N, Wolffsohn JS. Opportunities and threats to contact lens practice in Spain. JOURNAL OF OPTOMETRY 2023; 16:116-127. [PMID: 35821106 PMCID: PMC10104793 DOI: 10.1016/j.optom.2022.06.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Revised: 04/21/2022] [Accepted: 06/16/2022] [Indexed: 06/15/2023]
Abstract
OBJECTIVE An international survey evaluated the opportunities and threats related to contact lens practice reported by eye care professionals worldwide. This study reports on the results specifically found in Spain and how these compare with those from other regions of the world. METHODS A questionnaire was distributed to eye care practitioners around the world through professional associations. The questionnaire consisted of 9, 5 and 12 questions about opportunities, interventions, and potential threats related to contact lens practice, respectively. RESULTS A total of 2,408 responses were obtained from practitioners worldwide, of which 436 responses were obtained from Spanish practitioners. Spain was found among the regions with the highest perception of opportunities (median: 6.5/10) along with Australasia, North America, Europe, and South America. Spanish (median: 7.3/10), along with South American practitioners, also reported the highest perception of threats. Continuously updating of knowledge/skills, recommending contact lens wearing options to potential patients, creating an efficient recall system for follow-up examinations and being competent in managing contact lens-related complications were reported as important interventions for contact lens practice growth by Spanish eye care practitioners. CONCLUSIONS Spain is one of the regions in the world with the highest perception of both opportunities and threats regarding future contact lens practice. As such, Spanish practitioners consider it important to continuously update knowledge/skills and to recommend and educate patients on the benefits of contact lens wear. Online sales were found to be one of the most important concerns reported by both Spanish and eye care practitioners worldwide.
Collapse
Affiliation(s)
- Clara Martínez-Pérez
- Department of Pharmacy, Biotechnology, Nutrition, Optics and Optometry, Faculty of Biomedical and Health Sciences, European University of Madrid, Madrid, Spain
| | - César Villa-Collar
- Department of Pharmacy, Biotechnology, Nutrition, Optics and Optometry, Faculty of Biomedical and Health Sciences, European University of Madrid, Madrid, Spain
| | | | | | - Nilesh Thite
- International Association of Contact Lens Educators, Pune, India
| | | |
Collapse
|
14
|
Ponzini E, Recchioni A, Cheloni R, Zeri F, Tavazzi S. Physical Properties and Interaction With the Ocular Surface of Water-Gradient Contact Lenses. Eye Contact Lens 2023; 49:152-159. [PMID: 36811833 DOI: 10.1097/icl.0000000000000974] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/24/2023]
Abstract
ABSTRACT Since the introduction of silicone hydrogel contact lenses, many silicone-hydrogel materials have been produced, including water-gradient contact lenses with a silicone hydrogel core and a thin hydrogel outer layer (e.g., delefilcon A, verofilcon A, and lehfilcon A). Their properties have been investigated in various studies assessing both the chemical-physical characteristics and the comfort, but the overall picture is not always consistent. In this study, water-gradient technology is reviewed by looking at basic physical properties both in vitro and in vivo and at the interaction with the human ocular surface. Surface and bulk dehydration, surface wetting and dewetting, shear stress, interaction with tear components and with other environmental compounds, and comfort are discussed.
Collapse
Affiliation(s)
- Erika Ponzini
- Materials Science Department (E.P., F.Z., S.T.), University of Milano Bicocca, Via R. Cozzi 55-I-20125 Milan, Italy; COMiB Research Center (E.P., F.Z., S.T.), University of Milano Bicocca, Via R. Cozzi 55-I-20125 Milan, Italy; Academic Unit of Ophthalmology (A.R.), Institute of Inflammation and Ageing, University of Birmingham, UK; Birmingham and Midland Eye Centre (A.R.), Birmingham, UK; Optometry & Vision Sciences Group (A.R.), School of Life & Health Sciences, Aston University, Birmingham, 8UK; UCL Institute of Ophthalmology (R.C.), London, UK; and College of Health and Life Sciences (F.Z.), Aston University, Aston Triangle, Birmingham, B4 7ET, UK
| | | | | | | | | |
Collapse
|
15
|
Naroo SA, Eperjesi F, Woods C, Zeri F. Evidence based care is derived from good evidence-based teaching and learning. Cont Lens Anterior Eye 2023; 46:101823. [PMID: 36863933 DOI: 10.1016/j.clae.2023.101823] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/04/2023]
Affiliation(s)
- Shehzad A Naroo
- College of Health and Life Sciences, Aston University, UK; International Association of Contact Lens Educators, Canada.
| | | | - Craig Woods
- School of Optometry and Vision Science, University of New South Wales, Australia; International Association of Contact Lens Educators, Canada
| | - Fabrizio Zeri
- College of Health and Life Sciences, Aston University, UK; University of Milano-Bicocca, Department of Materials Science, Milan, Italy; International Association of Contact Lens Educators, Canada
| |
Collapse
|
16
|
Yokoi N, Eftimov P, Georgiev GA. Dynamic Aspects of Pre-Soft Contact Lens Tear Film and Their Relation to Dry Eye: Basic Science and Clinical Relevance. Life (Basel) 2023; 13:life13040859. [PMID: 37109389 PMCID: PMC10142029 DOI: 10.3390/life13040859] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2023] [Revised: 02/17/2023] [Accepted: 03/16/2023] [Indexed: 04/29/2023] Open
Abstract
Soft contact lens (SCL) perturbs the intimate connection between the pre-lens tear film (PLTF) and the ocular surface in various ways, i.e., (i) decrease in tear meniscus radius and aqueous tear thickness, (ii) attenuation of tear film lipid layer spread, (iii) limited wettability of SCL surface, (iv) increased friction with eyelid wiper, etc. This often results in SCL-related dry eye (SCLRDE) manifested as PLTF instability and contact lens discomfort (CLD). In this review, the individual contributions of factors (i-iv) to PLTF breakup patterns (BUP) and CLD are considered via the tear film-oriented diagnosis framework adopted by the Asia Dry Eye Society from a clinical and basic science perspective. It is shown that SCLRDE (due to aqueous deficiency, increased evaporation, or decreased wettability) and BUP of PLTF classify within the same types as the ones observed for the precorneal tear film. The analysis of PLTF dynamics reveals that the inclusion of SCL enhances the manifestation of BUP associated with (i) decreased thickness of PLTF aqueous layer and (ii) limited SCL wettability as shown by the rapid expansion of BUP area. PLTF thinness and instability result in increased blink-related friction and lid wiper epitheliopathy as major contributor to CLD.
Collapse
Affiliation(s)
- Norihiko Yokoi
- Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan
| | - Petar Eftimov
- Department of Cell and Developmental Biology, Faculty of Biology, Sofia University "St. Kliment Ohridski", 1164 Sofia, Bulgaria
| | - Georgi As Georgiev
- Department of Optics and Spectroscopy, Faculty of Physics, Sofia University "St. Kliment Ohridski", 1164 Sofia, Bulgaria
| |
Collapse
|
17
|
Pastrana C, Carpena-Torres C, Rodríguez-Pomar C, Martin-Gil A, Carracedo G. Improvement of Soft Contact Lens Wettability After the Instillation of Hyaluronic Acid Eye Drops. Eye Contact Lens 2023; 49:120-126. [PMID: 36700614 DOI: 10.1097/icl.0000000000000955] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/19/2022] [Indexed: 01/27/2023]
Abstract
PURPOSE To evaluate the effect of the topical instillation of hyaluronic acid eye drops with different viscosity on soft contact lens wettability and comfort. METHODS A randomized and participant-masked study was performed, involving 20 participants (25.4±2.6 years). One eye wore hydrogel (ocufilcon D) contact lenses, and another eye wore silicone-hydrogel (somofilcon A) contact lenses. The in vivo wettability tear film surface quality (TFSQ) index and comfort were measured before and after the instillation of different eye drops: saline solution (control) and 0.1%, 0.2%, and 0.3% hyaluronic acid. RESULTS Compared with saline solution, the instillation of 0.1%, 0.2%, and 0.3% hyaluronic acid improved the in vivo wettability of the hydrogel contact lenses by decreasing their TFSQ mean for 5, 10, and 30 min, respectively ( P <0.05). During silicone-hydrogel contact lens wear, the hyaluronic acid did not affect wettability because there were no changes in TFSQ mean ( P ≥0.05), but the 0.3% hyaluronic acid produced a decrease in comfort for the first 3 min ( P <0.05). CONCLUSIONS The instillation of hyaluronic acid eye drops increased the in vivo wettability of the hydrogel contact lens, and the duration of this effect was directly related to its concentration and viscosity.
Collapse
Affiliation(s)
- Cristina Pastrana
- Ocupharm Research Group, Department of Optometry and Vision, Faculty of Optics and Optometry, Complutense University of Madrid, Madrid, Spain
| | | | | | | | | |
Collapse
|
18
|
Cho P, Boost MV, Cheung SW. Ocular signs and symptoms of orthokeratology patients associated with povidone iodine-based disinfecting solution. Cont Lens Anterior Eye 2023; 46:101742. [PMID: 35931598 DOI: 10.1016/j.clae.2022.101742] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2022] [Revised: 07/15/2022] [Accepted: 07/18/2022] [Indexed: 01/18/2023]
Abstract
PURPOSE To determine the frequency and severity of ocular symptoms and signs in new orthokeratology (ortho-k) subjects using a povidone iodine (PI) disinfecting system compared to those present before lens wear, and whether these were associated with cleaning regimes. METHODS This study recruited 80 subjects from two myopia control studies, who used a PI disinfecting solution for routine use. Ocular symptoms and signs at baseline, one- and six-month after lens wear were reported via questionnaires and ocular examination, respectively. To determine if rates of occurrence were attributable to differences in cleaning regime, subjects were randomly assigned into four groups with respect to routine care procedures, which involved various combinations of rubbing and use of a daily and/or enzymatic cleaner. RESULTS Sixty-eight subjects completed all aspects of the study. As there were no significant differences in incidence of signs and symptoms between the four groups before and after lens wear (Friedman tests, p > 0.07), data were combined for further analysis. Prior to lens wear, itchiness (69 %) and dryness (53 %) were the most commonly reported symptoms. The frequency and severity of all symptoms remained similar after lens wear (p > 0.10). Presence of follicles in the lower tarsal conjunctiva (22 %) and conjunctival injection (15 %) was frequently observed, but reduced significantly after lens wear (p < 0.01). Mild corneal staining, noted in 13 % of subjects at baseline, did not change significantly over time (p = 0.17). Ocular signs were not necessarily reflected in symptoms and vice versa. CONCLUSION Use of a PI-based solution did not increase the frequency or severity of ocular signs and symptoms observed before lens wear. Absence of a difference in occurrence of ocular discomfort with respect to cleaning regimes indicated that the use of the PI-based solution may adequately clean the lenses over a 6-month period.
Collapse
Affiliation(s)
- Pauline Cho
- School of Optometry, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong Special Administrative Region
| | - Maureen Valerie Boost
- School of Optometry, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong Special Administrative Region
| | - Sin Wan Cheung
- School of Optometry, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong Special Administrative Region.
| |
Collapse
|
19
|
Contact Lens Wear Induces Alterations of Lactoferrin Functionality in Human Tears. Pharmaceutics 2022; 14:pharmaceutics14102188. [PMID: 36297623 PMCID: PMC9612143 DOI: 10.3390/pharmaceutics14102188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Revised: 10/10/2022] [Accepted: 10/12/2022] [Indexed: 11/06/2022] Open
Abstract
The tear film is a complex matrix composed of several molecular classes, from small metal ions to macromolecules. Contact lens (CL) wear can affect the protein homeostasis of the tear film, by accumulating deposits on the CL surface and/or altering their structural and functional properties. This work investigates the effect of CL wear on lactoferrin (Lf), one of the most abundant tear proteins, known as an unspecific biomarker of inflammation. Tears from eight volunteers were collected and analyzed after alternated periods of CL wear and without CL. The experimental approach is to probe Lf into unprocessed human tears by the peculiar fluorescence emission originating from complex formation of Lf with terbium (Tb3+) at the iron-binding sites. The experimental data indicate that CL wear does not significantly affect the total amount of Lf. On the other hand, Lf affinity for Tb3+ is reduced upon CL wear, suggesting relevant changes in Lf structure and possible alterations of protein functionality. Future studies based on this approach will help define CL features (material, lens-care solution, wearing time, etc.) with minimal effects on tear protein activity, in order to obtain more biocompatible and comfortable devices.
Collapse
|
20
|
Zheng Y, Dou J, Wang Y, Zhu L, Yao G, Kim YH, Radke CJ, Wu JY. Sustained Release of a Polymeric Wetting Agent from a Silicone-Hydrogel Contact Lens Material. ACS OMEGA 2022; 7:29223-29230. [PMID: 36033690 PMCID: PMC9404521 DOI: 10.1021/acsomega.2c03310] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/27/2022] [Accepted: 07/27/2022] [Indexed: 06/15/2023]
Abstract
Uptake and release kinetics are investigated of a dilute aqueous polymeric-surfactant wetting agent, (ethylene oxide)45-(butylene oxide)10 copolymer, also referred to as poly(oxyethylene)-co-poly(oxybutylene), impregnated into a newly designed silicone-hydrogel lens material. Transient scanning concentration profiles of the fluorescently tagged polymeric surfactant follow Fick's second law with a diffusion coefficient near 10-11 cm2/s, a value 3-4 orders smaller than that of the free surfactant in bulk water. The Nernst partition coefficient of the tagged polymeric wetting agent, determined by fluorescence microscopy and by methanol extraction, is near 350, a very large value. Back-extraction of the polymeric-surfactant wetting agent releases only ∼20% of the loaded amount after soaking the fully loaded lens for over 7 days. The remaining ∼80% is irreversibly bound in the lens matrix. Reverse-phase liquid chromatography of the lens-loaded and lens-extracted surfactant demonstrates that the released wetting agent is more hydrophilic with a higher polarity. Aqueous poly(oxyethylene)-co-poly(oxybutylene) is hypothesized to attach strongly to the lens matrix, most likely to the lens silicone domains. Strong binding leads to slow transient diffusion, to large uptake, and to significant irreversible retention. These characteristics indicate the suitability of using a poly(oxyethylene)-co-poly(oxybutylene) nonionic polymeric surfactant to maintain enhanced lens wettability over time. Methodology and findings from this study provide useful insights for designing sustained-release contact-lens wetting agents and materials.
Collapse
Affiliation(s)
- Ying Zheng
- Alcon
Research LLC, 11460 Johns
Creek Parkway, Duluth, Georgia 30097, United States
| | - Jinbo Dou
- Alcon
Research LLC, 11460 Johns
Creek Parkway, Duluth, Georgia 30097, United States
| | - Yan Wang
- Alcon
Research LLC, 11460 Johns
Creek Parkway, Duluth, Georgia 30097, United States
| | - Lu Zhu
- Alcon
Research LLC, 11460 Johns
Creek Parkway, Duluth, Georgia 30097, United States
| | - George Yao
- Alcon
Research LLC, 11460 Johns
Creek Parkway, Duluth, Georgia 30097, United States
- Alcon
Research LLC, 6201 South
Freeway, Fort Worth, Texas 76134, United States
| | - Young Hyun Kim
- Alcon
Research LLC, 11460 Johns
Creek Parkway, Duluth, Georgia 30097, United States
- Chemical
and Biomolecular Engineering Department, University of California, Berkeley, California 94720, United States
- Herbert
Wertheim School of Optometry & Vision Science, University of California, Berkeley, California 94720, United States
| | - Clayton J. Radke
- Chemical
and Biomolecular Engineering Department, University of California, Berkeley, California 94720, United States
- Herbert
Wertheim School of Optometry & Vision Science, University of California, Berkeley, California 94720, United States
| | - James Yuliang Wu
- Alcon
Research LLC, 11460 Johns
Creek Parkway, Duluth, Georgia 30097, United States
- Alcon
Research LLC, 6201 South
Freeway, Fort Worth, Texas 76134, United States
| |
Collapse
|
21
|
Wang Y, Jacobs DS. Role of therapeutic contact lenses in management of corneal disease. Curr Opin Ophthalmol 2022; 33:306-310. [PMID: 35779054 DOI: 10.1097/icu.0000000000000859] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE OF REVIEW The current review highlights areas of innovation and research in the use of contact lenses in the treatment of corneal ectasia and ocular surface disease. RECENT FINDINGS A series of academic reports were published by a committee of experts reviewing evidence-based practice patterns of contact lens use. There continues to be active research in the use of contact lenses in the management of keratoconus, including mini-scleral lenses, custom impression-based scleral lenses and wavefront-guided scleral lenses. Recent reports on contact lenses for ocular surface disease were primarily reviews, retrospective case reports or case series, with publications on contact lens use in corneal epithelial defects, graft-vs.-host disease, limbal stem cell deficiency and neurotrophic keratitis. There are recent publications on advances in drug-eluting contact lenses. SUMMARY Corneal specialists should be aware of current advances in the field of contact lens expanding their use in corneal ectasia and ocular surface disease.
Collapse
Affiliation(s)
- Yvonne Wang
- Department of Ophthalmology, Yale School of Medicine, New Haven, Connecticut
| | - Deborah S Jacobs
- Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
22
|
Multipurpose Lens Care Systems and Silicone Hydrogel Contact Lens Wettability: A Systematic Review. Eye Contact Lens 2022; 48:356-361. [DOI: 10.1097/icl.0000000000000914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/12/2022] [Indexed: 11/26/2022]
|
23
|
Recchioni A, Mocciardini E, Ponzini E, Tavazzi S. Viscoelastic properties of the human tear film. Exp Eye Res 2022; 219:109083. [PMID: 35460666 DOI: 10.1016/j.exer.2022.109083] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Revised: 03/25/2022] [Accepted: 04/18/2022] [Indexed: 12/21/2022]
Abstract
When considering eye blinking from a tribological perspective, tear viscosity is expected to play a fundamental role. The application of rheological techniques to describe the tear film dates back to the late 1980s, but there has been a continuous need of reappraisal due to new findings in tear film biochemistry and to the development of new methods of physico-chemical characterization. This review provides an overview on tear rheological behavior by analyzing the peer-reviewed literature on this topic. Specifically, examples of in-vitro and in-vivo viscosity measurements are detailed, highlighting experimental criticalities and the need of a standard convention for rheological techniques to compare data across different studies, of analyses on tears of single individuals even within the limits of the low volume available, and of a further development of in-vivo techniques. Then, the controversial role of specific tear components on viscosity is discussed, together with the alterations associated to dry eye disease and contact lens wear. Finally, an updated focus is reported on the viscosity of artificial tears formulations.
Collapse
Affiliation(s)
- Alberto Recchioni
- Academic Unit of Ophthalmology, Institute of Inflammation and Ageing, University of Birmingham, UK; Optometry & Vision Sciences Group, School of Life & Health Sciences, Aston University, Birmingham, UK; Birmingham and Midland Eye Centre, Birmingham, UK
| | - Emanuele Mocciardini
- University of Milano Bicocca, Corso di laurea in Ottica e Optometria, via R. Cozzi 55, I-20125, Milan, Italy
| | - Erika Ponzini
- University of Milano Bicocca, Materials Science Department, via R. Cozzi 55, I-20125, Milan, Italy; University of Milano Bicocca, COMiB research center, via R. Cozzi 55, I-20125, Milan, Italy.
| | - Silvia Tavazzi
- University of Milano Bicocca, Materials Science Department, via R. Cozzi 55, I-20125, Milan, Italy; University of Milano Bicocca, COMiB research center, via R. Cozzi 55, I-20125, Milan, Italy
| |
Collapse
|
24
|
Influence of Selected Ophthalmic Fluids on the Wettability and Hydration of Hydrogel and Silicone Hydrogel Contact Lenses—In Vitro Study. MATERIALS 2022; 15:ma15030930. [PMID: 35160876 PMCID: PMC8839750 DOI: 10.3390/ma15030930] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/24/2021] [Revised: 01/11/2022] [Accepted: 01/20/2022] [Indexed: 11/16/2022]
Abstract
This study attempts to evaluate the effect of incubation in selected ophthalmic fluids on contact lenses (Etafilcon A, Omafilcon A, Narafilcon A, Senofilcon A). Four research groups differing in the incubation environment were created: (1) initial state, (2) contact lens solution (CLS), (3) contact lens solution and eye drops (ED) and (4) eye drops. Dehydration by gravimetric method and the contact angle (CA) by the sessile drop method were tested. The surface free energy (SFE) was also calculated with the use of several methods: Owens–Wendt, Wu, Neumann, and Neumann–Kwok. The greatest changes in the dehydration profile were observed for contact lenses incubated in ED. The most noticeable changes in CA values were observed for contact lenses incubated in ED, in which it was not possible to settle water drop after incubation. On the basis of SFE analysis, higher values were found for hydrogel contact lenses, e.g., according to the Owens–Wendt method, they ranged from 54.45 ± 6.56 mJ/m2 to 58.09 ± 4.86 mJ/m2, while in the case of silicone-hydrogel contact lenses, they ranged from 32.86 ± 3.47 mJ/m2 to 35.33 ± 6.56 mJ/m2. Incubation in all tested environments decreased the SFE values, but the differences were in most cases statistically insignificant. Calculating the SFE may be a useful method as it can be used to estimate the possibility of bacteria adhering to contact lens surfaces.
Collapse
|
25
|
Kalaiselvan P, Dutta D, Konda N, Vaddavalli PK, Sharma S, Stapleton F, Willcox MDP. Biocompatibility and Comfort during Extended Wear of Mel4 Peptide-Coated Antimicrobial Contact Lenses. Antibiotics (Basel) 2022; 11:antibiotics11010058. [PMID: 35052935 PMCID: PMC8772808 DOI: 10.3390/antibiotics11010058] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Revised: 12/30/2021] [Accepted: 12/31/2021] [Indexed: 02/05/2023] Open
Abstract
(1) Purpose: This study aimed to investigate the effects of Mel4 antimicrobial contact lenses (MACL) on the ocular surface and comfort during extended wear. (2) Methods: A prospective, randomised, double-masked, contralateral clinical trial was conducted with 176 subjects to evaluate the biocompatibility of contralateral wear of MACL. The wearing modality was 14-day extended lens wear for three months. The participants were assessed at lens dispensing, after one night, two weeks, one month and three months of extended wear and one month after study completion. (3) Results: There were no significant differences (p > 0.05) in ocular redness or palpebral roughness between Mel4 and control eyes at any of the study visits. There was no significant difference (p > 0.05) in corneal staining between Mel4 and control eyes. There were no significant differences in front surface wettability or deposits or back surface debris (p > 0.05). No statistically significant differences (p > 0.05) were found in comfort, dryness, CLDEQ-8 scores lens or edge awareness. There was no evidence for delayed reactions on the ocular surface after cessation of lens wear. (4) Conclusion: The novel MACLs showed similar comfort to control lenses and were biocompatible during extended wear. Thus, these lenses were compatible with the ocular surface.
Collapse
Affiliation(s)
- Parthasarathi Kalaiselvan
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW 2041, Australia; (D.D.); (F.S.); (M.D.P.W.)
- Correspondence:
| | - Debarun Dutta
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW 2041, Australia; (D.D.); (F.S.); (M.D.P.W.)
- School of Optometry, Aston University, Birmingham B4 7ET, UK
| | - Nagaraju Konda
- School of Medical Sciences, University of Hyderabad, Hyderabad 500 046, India;
| | - Pravin Krishna Vaddavalli
- Bausch & Lomb Contact Lens Centre, L V Prasad Eye Institute, Hyderabad 500 034, India;
- The Cornea Institute, L V Prasad Eye Institute, Hyderabad 500 034, India
| | - Savitri Sharma
- Jhaveri Microbiology Centre, L V Prasad Eye Institute, Hyderabad 500 034, India;
| | - Fiona Stapleton
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW 2041, Australia; (D.D.); (F.S.); (M.D.P.W.)
| | - Mark D. P. Willcox
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW 2041, Australia; (D.D.); (F.S.); (M.D.P.W.)
| |
Collapse
|
26
|
Koh S, Chalmers R, Yamasaki K, Kawasaki R, Nishida K. Factors influencing the 8-item contact lens dry eye questionnaire score and comparison of translations in Japanese soft contact lens wearers. Cont Lens Anterior Eye 2021; 45:101519. [PMID: 34620551 DOI: 10.1016/j.clae.2021.101519] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Revised: 08/21/2021] [Accepted: 09/27/2021] [Indexed: 11/03/2022]
Abstract
PURPOSE To determine (1) the factors associated with a high degree of self-reported symptoms with Japanese translations of the 8-Item Contact Lens Dry Eye Questionnaire (J-CLDEQ-8) in a cross-section of soft contact lens (SCL) wearers in Japan and (2) whether the difference in translation of the CLDEQ-8 affects the scores between validated and non-validated versions of the Japanese translation. METHODS Habitual SCL wearers completed the validated J-CLDEQ-8 and a previous non-validated version. Demographics and SCL history questions were queried when they presented for routine eye care in nine geographically distinct clinics across Japan. The following risk factors for high J-CLDEQ-8 scores (≥11) were tested: sex, age, SCL replacement (daily disposable vs. bi-weekly and monthly reusable), years of SCL wear, and self-reported use of rewetting drops. The scores of the validated and non-validated questionnaires were compared. RESULTS Significant patient-related risk factors for high J-CLDEQ-8 scores were female sex, use of reusable SCLs, longer years of SCL wear, and use of rewetting drops. Scores for six out of eight questions in the validated J-CLDEQ-8 were significantly higher than those of the non-validated version, resulting in a significant difference in the average total score between the two questionnaires (validated J-CLDEQ-8: 10.5 ± 5.9 vs non-validated J-CLDEQ-8: 9.5 ± 5.8, P < 0.001). CONCLUSIONS Female sex, use of reusable SCLs, longer years of SCL wear, and use of rewetting drops were significant risk factors for high J-CLDEQ-8 scores in a cross-sectional clinical population of Japanese SCL wearers. Symptoms with SCL are not predicted by age and must therefore be queried at follow-up visits for all SCL wearers. Differences in the two translations affected the ability of the questionnaire to identify individuals with high symptoms associated with SCL wear.
Collapse
Affiliation(s)
- Shizuka Koh
- Department of Innovative Visual Science, Osaka University Graduate School of Medicine, Osaka, Japan; Department of Ophthalmology, Osaka University Graduate School of Medicine, Osaka, Japan.
| | | | | | - Ryo Kawasaki
- Department of Ophthalmology, Osaka University Graduate School of Medicine, Osaka, Japan; Department of Vision Informatics, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Kohji Nishida
- Department of Ophthalmology, Osaka University Graduate School of Medicine, Osaka, Japan
| |
Collapse
|
27
|
Yasir M, Kumar Vijay A, Willcox M. Antiviral effect of multipurpose contact lens disinfecting solutions against coronavirus. Cont Lens Anterior Eye 2021; 45:101513. [PMID: 34465537 PMCID: PMC8390374 DOI: 10.1016/j.clae.2021.101513] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Revised: 08/14/2021] [Accepted: 08/23/2021] [Indexed: 02/06/2023]
Abstract
Purpose To evaluate the antiviral potential of five multipurpose disinfecting solutions against coronavirus (mouse hepatitis virus, a surrogate for SARS-CoV-2 human corona virus). Methods Test solutions (Biotrue, renu Advanced [Bausch and Lomb], ACUVUE RevitaLens [Johnson and Johnson Vision], cleadew [Ophtecs corp.] or AOSept Plus [Alcon]) were mixed with the coronavirus mouse hepatitis virus at 104 plaque forming units (PFU)/mL as the final concentration and incubated at room temperature for the specified disinfection time. Surviving virus from each sample was then quantified by standard plaque forming unit assay and the reduction of PFU for each disinfectant was compared to the phosphate buffer saline (PBS) treated negative control. A regimen test was also conducted using Biotrue. Results The three multipurpose disinfecting solutions Biotrue (containing PHMB and polyquaternium-1), renu Advanced (PHMB, polyquaternium-1 and alexidine) and ACUVUE RevitaLens (polyquaternium-1 and alexidine) did not kill the coronavirus at the manufacturers recommended disinfection time in the stand alone test. After treatment, the virus’s titer (3.8 ± 0.2 log10 for Biotrue, 3.7 ± 0.1 log10 for renu and 3.7 ± 0.2 log10 for RevitaLens) was similar to the negative control (3.7 ± 0.1 log10; p ≥ 0.996). AOSept Plus (hydrogen peroxide) and cleadew (povidone iodine) significantly (p < 0.001) reduced the numbers of coronaviruses to below the detection limit (i.e. killed 3.7 ± 0.1 log10 viruses compared to control). However, there was a significant reduction (p = 0.028) in numbers of coronaviruses attached to lenses when using the regimen test with Biotrue. Conclusions This study shows that oxidative contact lens disinfecting solutions (i.e. those containing povidone-iodine or hydrogen peroxide) provide superior antiviral activity against a coronavirus surrogate of SARS-CoV-2, unless the full regimen test (rub, rinse, disinfect) is used.
Collapse
Affiliation(s)
- Muhammad Yasir
- School of Optometry and Vision Science, University of New South Wales, NSW 2052, Australia
| | - Ajay Kumar Vijay
- School of Optometry and Vision Science, University of New South Wales, NSW 2052, Australia
| | - Mark Willcox
- School of Optometry and Vision Science, University of New South Wales, NSW 2052, Australia.
| |
Collapse
|
28
|
Carpena-Torres C, Pastrana C, Rodríguez-Pomar C, Serramito M, Carracedo G. Stabilization of comfort and visual quality after the insertion of soft contact lenses. Cont Lens Anterior Eye 2021; 45:101498. [PMID: 34373201 DOI: 10.1016/j.clae.2021.101498] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2021] [Revised: 07/20/2021] [Accepted: 08/01/2021] [Indexed: 11/03/2022]
Abstract
PURPOSE To evaluate comfort, visual function, and in vivo wettability after the insertion of hydrogel and silicone hydrogel contact lenses for a better understanding of how long practitioners should wait for the initial evaluation of soft contact lenses. METHODS A short-term prospective, contralateral, randomized, and participant-masked study was carried out. Twenty healthy participants (25.4 ± 2.6 years) were evaluated after the insertion of two different soft contact lenses at different times (1, 5, 10, 20, 30 min). Ocufilcon D (hydrogel) and Somofilcon A (silicone hydrogel) contact lenses were randomly assigned to both eyes of the same participant. Comfort, visual function under photopic conditions in terms of high-contrast visual acuity, low-contrast visual acuity, contrast sensitivity, and in vivo wettability were measured. RESULTS There was an increase in comfort (p < 0.001), high-contrast visual acuity (p < 0.05), and contrast sensitivity (p < 0.001, only with silicone hydrogel) directly related to time after contact lens insertion. Besides, in vivo wettability suffered a statistically significant deterioration directly related to time with both contact lenses (p < 0.05). Except for comfort and contrast sensitivity, all the parameters stabilized their values 10 min after the insertion of both soft contact lenses. Additionally, in vivo wettability and visual acuity differences were found between hydrogel and silicone hydrogel contact lenses (p < 0.05). CONCLUSIONS It would be possible to properly evaluate high-contrast visual acuity, low-contrast visual acuity, and in vivo wettability 10 min after the insertion of both soft contact lenses.
Collapse
Affiliation(s)
- Carlos Carpena-Torres
- Ocupharm Research Group, Department of Optometry and Vision, Faculty of Optics and Optometry, Complutense University of Madrid, Madrid, Spain
| | - Cristina Pastrana
- Ocupharm Research Group, Department of Optometry and Vision, Faculty of Optics and Optometry, Complutense University of Madrid, Madrid, Spain
| | - Candela Rodríguez-Pomar
- Ocupharm Research Group, Department of Optometry and Vision, Faculty of Optics and Optometry, Complutense University of Madrid, Madrid, Spain
| | - María Serramito
- Ocupharm Research Group, Department of Optometry and Vision, Faculty of Optics and Optometry, Complutense University of Madrid, Madrid, Spain
| | - Gonzalo Carracedo
- Ocupharm Research Group, Department of Optometry and Vision, Faculty of Optics and Optometry, Complutense University of Madrid, Madrid, Spain.
| |
Collapse
|
29
|
Miglio F, Ponzini E, Zeri F, Borghesi A, Tavazzi S. In vitro affinity for nicotine of soft contact lenses of different materials. Cont Lens Anterior Eye 2021; 45:101490. [PMID: 34294534 DOI: 10.1016/j.clae.2021.101490] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 07/02/2021] [Accepted: 07/07/2021] [Indexed: 02/06/2023]
Abstract
Smoking is a risk factor for the development of microbial keratitis and corneal infiltrates in contact lens (CL) wearers. It is still unknown if this risk is directly associated with the presence of nicotine in the eye and if adherence of nicotine on the CL can enhance these effects. A better understanding of the interaction between nicotine and CL materials could offer insights to explain this risk associated with smoking. The aim of this work was to compare the affinity of nicotine to different soft CL materials. CLs from FDA groups I, II, IV, and V were incubated in a 2-mM nicotine solution for 24 h and then in a 0.9% saline solution for the next 24 h. The amount of absorbed and released nicotine per CL was deduced as a function of time (t) by ultraviolet (UV) spectrophotometry and normalised to the mass of the hydrated CL. The data were described by the equation y = b -a t-1, where a and b are constants, and b represents the mass reached at the plateau after ~ 10 min of exposure. Groups IV and V displayed the highest (0.80 ± 0.09 µg) and lowest (0.27 ± 0.08 µg) nicotine absorption per mg of hydrated CL, respectively. The CL affinity for nicotine could be ascribed to the interaction between the positive charge of nicotine pyrrolidine nitrogen and the negative charges of the CLs, especially for the ionic IV group.
Collapse
Affiliation(s)
- Federica Miglio
- University of Milano Bicocca, Materials Science Department, via R. Cozzi 55, I-20125 Milan, Italy; University of Milano Bicocca, COMiB Research Center, via R. Cozzi 55, I-20125 Milan, Italy
| | - Erika Ponzini
- University of Milano Bicocca, Materials Science Department, via R. Cozzi 55, I-20125 Milan, Italy; University of Milano Bicocca, COMiB Research Center, via R. Cozzi 55, I-20125 Milan, Italy.
| | - Fabrizio Zeri
- University of Milano Bicocca, Materials Science Department, via R. Cozzi 55, I-20125 Milan, Italy; University of Milano Bicocca, COMiB Research Center, via R. Cozzi 55, I-20125 Milan, Italy; School of Life & Health Sciences, Aston University, Aston Triangle, Birmingham B4 7ET, UK
| | - Alessandro Borghesi
- University of Milano Bicocca, Materials Science Department, via R. Cozzi 55, I-20125 Milan, Italy; University of Milano Bicocca, COMiB Research Center, via R. Cozzi 55, I-20125 Milan, Italy
| | - Silvia Tavazzi
- University of Milano Bicocca, Materials Science Department, via R. Cozzi 55, I-20125 Milan, Italy; University of Milano Bicocca, COMiB Research Center, via R. Cozzi 55, I-20125 Milan, Italy
| |
Collapse
|
30
|
Vincent SJ, Cho P, Chan KY, Fadel D, Ghorbani-Mojarrad N, González-Méijome JM, Johnson L, Kang P, Michaud L, Simard P, Jones L. CLEAR - Orthokeratology. Cont Lens Anterior Eye 2021; 44:240-269. [DOI: 10.1016/j.clae.2021.02.003] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 02/01/2021] [Indexed: 12/25/2022]
|
31
|
CLEAR - Contact lens complications. Cont Lens Anterior Eye 2021; 44:330-367. [DOI: 10.1016/j.clae.2021.02.010] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2021] [Accepted: 02/01/2021] [Indexed: 12/20/2022]
|
32
|
Downie LE, Bandlitz S, Bergmanson JPG, Craig JP, Dutta D, Maldonado-Codina C, Ngo W, Siddireddy JS, Wolffsohn JS. CLEAR - Anatomy and physiology of the anterior eye. Cont Lens Anterior Eye 2021; 44:132-156. [PMID: 33775375 DOI: 10.1016/j.clae.2021.02.009] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Accepted: 02/01/2021] [Indexed: 02/06/2023]
Abstract
A key element of contact lens practice involves clinical evaluation of anterior eye health, including the cornea and limbus, conjunctiva and sclera, eyelids and eyelashes, lacrimal system and tear film. This report reviews the fundamental anatomy and physiology of these structures, including the vascular supply, venous drainage, lymphatic drainage, sensory innervation, physiology and function. This is the foundation for considering the potential interactions with, and effects of, contact lens wear on the anterior eye. This information is not consistently published as academic research and this report provides a synthesis from all available sources. With respect to terminology, the report aims to promote the consistent use of nomenclature in the field, and generally adopts anatomical terms recommended by the Federative Committee for Anatomical Terminology. Techniques for the examination of the ocular surface are also discussed.
Collapse
Affiliation(s)
- Laura E Downie
- Department of Optometry and Vision Sciences, The University of Melbourne, Australia.
| | - Stefan Bandlitz
- Höhere Fachschule für Augenoptik Köln, Cologne School of Optometry, Germany; School of Optometry, Aston University, Birmingham, UK
| | - Jan P G Bergmanson
- Texas Eye Research and Technology Center, University of Houston College of Optometry, United States
| | - Jennifer P Craig
- Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, New Zealand
| | - Debarun Dutta
- School of Optometry, Aston University, Birmingham, UK
| | - Carole Maldonado-Codina
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, UK
| | - William Ngo
- Centre for Ocular Research & Education, School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada; Centre for Eye and Vision Research (CEVR), 14W Hong Kong Science Park, Hong Kong
| | | | - James S Wolffsohn
- School of Optometry, Aston University, Birmingham, UK; Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, New Zealand
| |
Collapse
|
33
|
Wolffsohn JS, Dumbleton K, Huntjens B, Kandel H, Koh S, Kunnen CME, Nagra M, Pult H, Sulley AL, Vianya-Estopa M, Walsh K, Wong S, Stapleton F. CLEAR - Evidence-based contact lens practice. Cont Lens Anterior Eye 2021; 44:368-397. [PMID: 33775383 DOI: 10.1016/j.clae.2021.02.008] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Accepted: 02/01/2021] [Indexed: 12/15/2022]
Abstract
Evidence-based contact lens -->practice involves finding, appraising and applying research findings as the basis for patient management decisions. These decisions should be informed by the strength of the research study designs that address the question, as well as by the experience of the practitioner and the preferences and environment of the patient. This reports reviews and summarises the published research evidence that is available to inform soft and rigid contact lens history and symptoms taking, anterior eye health examination (including the optimised use of ophthalmic dyes, grading scales, imaging techniques and lid eversion), considerations for contact lens selection (including the ocular surface measurements required to select the most appropriate lens parameter, lens modality and material selection), evaluation of lens fit, prescribing (teaching self-application and removal, adaptation, care regimen and cleaning instructions, as well as -->minimising risks of lens wear through encouraging compliance) and an aftercare routine.
Collapse
Affiliation(s)
| | - Kathy Dumbleton
- School of Optometry, University of California, Berkeley, CA, USA
| | - Byki Huntjens
- Division of Optometry and Visual Sciences at City, University of London, London, UK
| | - Himal Kandel
- Save Sight Institute, Sydney Medical School, The University of Sydney, Sydney, Australia
| | - Shizuka Koh
- Department of Innovative Visual Science, Osaka University Graduate School of Medicine, Japan
| | | | - Manbir Nagra
- Vision and Eye Research Institute, ARU, Cambridge, UK
| | - Heiko Pult
- Optometry and Vision Research, Weinheim, Germany
| | | | - Marta Vianya-Estopa
- Department of Vision and Hearing Sciences Research Centre, Anglia Ruskin University, Cambridge, UK
| | - Karen Walsh
- Centre for Ocular Research & Education, School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada
| | - Stephanie Wong
- Centre for Ocular Research & Education, School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada
| | - Fiona Stapleton
- School of Optometry and Vision Science, UNSW Sydney, Australia
| |
Collapse
|
34
|
Wolffsohn JS, Morgan PB, Barnett M, Downie LE, Jacobs DS, Jones L, Richdale K, Stapleton F, Vincent SJ, Willcox M. Contact Lens Evidence-Based Academic Reports (CLEAR). Cont Lens Anterior Eye 2021; 44:129-131. [PMID: 33775374 DOI: 10.1016/j.clae.2021.02.011] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2021] [Accepted: 02/01/2021] [Indexed: 12/30/2022]
Affiliation(s)
| | - Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, UK
| | - Melissa Barnett
- University of California, Davis Eye Center, Sacramento, CA, USA
| | - Laura E Downie
- Department of Optometry and Vision Sciences, The University of Melbourne, Australia
| | - Deborah S Jacobs
- Massachusetts Eye & Ear, Cornea and Refractive Surgery Service, Boston, MA, USA; Harvard Medical School, Boston, MA, USA
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada; Centre for Eye and Vision Research (CEVR), Hong Kong
| | | | - Fiona Stapleton
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia
| | - Stephen J Vincent
- Queensland University of Technology (QUT), Centre for Vision and Eye Research, School of Optometry and Vision Science, Contact Lens and Visual Optics Laboratory, Brisbane, Australia
| | - Mark Willcox
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia
| |
Collapse
|
35
|
Jones L, Hui A, Phan CM, Read ML, Azar D, Buch J, Ciolino JB, Naroo SA, Pall B, Romond K, Sankaridurg P, Schnider CM, Terry L, Willcox M. CLEAR - Contact lens technologies of the future. Cont Lens Anterior Eye 2021; 44:398-430. [PMID: 33775384 DOI: 10.1016/j.clae.2021.02.007] [Citation(s) in RCA: 33] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Accepted: 02/01/2021] [Indexed: 12/20/2022]
Abstract
Contact lenses in the future will likely have functions other than correction of refractive error. Lenses designed to control the development of myopia are already commercially available. Contact lenses as drug delivery devices and powered through advancements in nanotechnology will open up further opportunities for unique uses of contact lenses. This review examines the use, or potential use, of contact lenses aside from their role to correct refractive error. Contact lenses can be used to detect systemic and ocular surface diseases, treat and manage various ocular conditions and as devices that can correct presbyopia, control the development of myopia or be used for augmented vision. There is also discussion of new developments in contact lens packaging and storage cases. The use of contact lenses as devices to detect systemic disease has mostly focussed on detecting changes to glucose levels in tears for monitoring diabetic control. Glucose can be detected using changes in colour, fluorescence or generation of electric signals by embedded sensors such as boronic acid, concanavalin A or glucose oxidase. Contact lenses that have gained regulatory approval can measure changes in intraocular pressure to monitor glaucoma by measuring small changes in corneal shape. Challenges include integrating sensors into contact lenses and detecting the signals generated. Various techniques are used to optimise uptake and release of the drugs to the ocular surface to treat diseases such as dry eye, glaucoma, infection and allergy. Contact lenses that either mechanically or electronically change their shape are being investigated for the management of presbyopia. Contact lenses that slow the development of myopia are based upon incorporating concentric rings of plus power, peripheral optical zone(s) with add power or non-monotonic variations in power. Various forms of these lenses have shown a reduction in myopia in clinical trials and are available in various markets.
Collapse
Affiliation(s)
- Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada; Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong.
| | - Alex Hui
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW, Australia
| | - Chau-Minh Phan
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada; Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong
| | - Michael L Read
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| | - Dimitri Azar
- Department of Ophthalmology and Visual Sciences, University of Illinois College of Medicine, Chicago, IL, USA; Verily Life Sciences, San Francisco, CA, USA
| | - John Buch
- Johnson & Johnson Vision Care, Jacksonville, FL, USA
| | - Joseph B Ciolino
- Department of Ophthalmology, Massachusetts Eye and Ear Infirmary, Harvard Medical School, Boston, MA, USA
| | - Shehzad A Naroo
- College of Health and Life Sciences, Aston University, Birmingham B4 7ET, UK
| | - Brian Pall
- Johnson & Johnson Vision Care, Jacksonville, FL, USA
| | - Kathleen Romond
- Department of Ophthalmology and Visual Sciences, University of Illinois College of Medicine, Chicago, IL, USA
| | - Padmaja Sankaridurg
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW, Australia; Brien Holden Vision Institute, Sydney, Australia
| | | | - Louise Terry
- School of Optometry and Vision Sciences, Cardiff University, UK
| | - Mark Willcox
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW, Australia
| |
Collapse
|
36
|
Morgan PB, Murphy PJ, Gifford KL, Gifford P, Golebiowski B, Johnson L, Makrynioti D, Moezzi AM, Moody K, Navascues-Cornago M, Schweizer H, Swiderska K, Young G, Willcox M. CLEAR - Effect of contact lens materials and designs on the anatomy and physiology of the eye. Cont Lens Anterior Eye 2021; 44:192-219. [PMID: 33775377 DOI: 10.1016/j.clae.2021.02.006] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 02/01/2021] [Indexed: 12/19/2022]
Abstract
This paper outlines changes to the ocular surface caused by contact lenses and their degree of clinical significance. Substantial research and development to improve oxygen permeability of rigid and soft contact lenses has meant that in many countries the issues caused by hypoxia to the ocular surface have largely been negated. The ability of contact lenses to change the axial growth characteristics of the globe is being utilised to help reduce the myopia pandemic and several studies and meta-analyses have shown that wearing orthokeratology lenses or soft multifocal contact lenses can reduce axial length growth (and hence myopia). However, effects on blinking, ptosis, the function of Meibomian glands, fluorescein and lissamine green staining of the conjunctiva and cornea, production of lid-parallel conjunctival folds and lid wiper epitheliopathy have received less research attention. Contact lens wear produces a subclinical inflammatory response manifested by increases in the number of dendritiform cells in the conjunctiva, cornea and limbus. Papillary conjunctivitis is also a complication of all types of contact lenses. Changes to wear schedule (daily disposable from overnight wear) or lens materials (hydrogel from SiHy) can reduce papillary conjunctivitis, but the effect of such changes on dendritic cell migration needs further study. These changes may be associated with decreased comfort but confirmatory studies are needed. Contact lenses can affect the sensitivity of the ocular surface to mechanical stimulation, but whether these changes affect comfort requires further investigation. In conclusion, there have been changes to lens materials, design and wear schedules over the past 20+ years that have improved their safety and seen the development of lenses that can reduce the myopia development. However, several changes to the ocular surface still occur and warrant further research effort in order to optimise the lens wearing experience.
Collapse
Affiliation(s)
- Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, UK.
| | - Paul J Murphy
- University of Waterloo, School of Optometry and Vision Science, Waterloo, Canada
| | - Kate L Gifford
- School of Optometry and Vision Science, Queensland University of Technology, Brisbane, Australia
| | - Paul Gifford
- School of Optometry and Vision Science, UNSW Sydney, Australia
| | | | - Leah Johnson
- CooperVision Specialty EyeCare, Gilbert, AZ, United States
| | - Dimitra Makrynioti
- School of Health Rehabilitation Sciences, University of Patras (Aigio), Greece
| | - Amir M Moezzi
- Centre for Ocular Research and Education, University of Waterloo, Canada
| | - Kurt Moody
- Johnson & Johnson Vision Care, Jacksonville, FL, United States
| | | | | | - Kasandra Swiderska
- Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, UK
| | | | - Mark Willcox
- School of Optometry and Vision Science, UNSW Sydney, Australia
| |
Collapse
|