1
|
Nooh A, Aoude A, Hart A, Tanzer M, Turcotte RE. Taper Junction Subsidence Occurs in Modular Tumor Endoprostheses: How Concerned Should We Be? Clin Orthop Relat Res 2024:00003086-990000000-01695. [PMID: 39243359 DOI: 10.1097/corr.0000000000003205] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Accepted: 07/08/2024] [Indexed: 09/09/2024]
Abstract
BACKGROUND Advancements in musculoskeletal oncologic treatment have allowed for longer survival of patients with malignant bone tumors and the associated longer use of tumor endoprostheses in those who have had such reconstructions. Several studies have reported on increased serum metal ions with the use of such implants. Modularity in these implants introduces the risk of taper junction corrosion and subsidence resulting in metal wear particle release that may cause an adverse local tissue reaction or systemic toxicity. Additionally, these implants contain a large surface area of cobalt and chromium. It is unclear whether the source of the increased serum ion levels was due to the taper junction corrosion or the implant itself. To our knowledge, no prior study has reported on taper junction subsidence. QUESTIONS/PURPOSES In this study we sought (1) to determine survivorship free from radiographic taper junction subsidence in a femoral modular tumor endoprosthesis, and (2) to identify the implant characteristics in the endoprostheses associated with taper subsidence. METHODS Between January 1996 and February 2020, the senior author performed 150 proximal or distal femur replacements following resections of soft tissue or bone tumors of the thigh and femur. Of those, 6% (9 of 150) of patients were lost to follow-up before 2 years, 25% (37 of 150) could not be analyzed due to absence of plain radiographs during follow-up, and 13% (20 of 150) died before 2 years follow-up, leaving 56% (84 of 150) for analysis in this retrospective study, with a median time for analysis of 14 years (range 2 to 31 years) after the index resection and endoprosthetic reconstruction for patients with distal femur replacements and 5 years (range 2 to 19 years) for patients with proximal femur replacement. Radiographs involving the entire implant were evaluated for the presence or absence of subsidence of the taper junction that was evident and clear to see if present. The association between the number of taper junctions, the length of resection, the number of collapsed junctions, and the time to collapse from the initial surgery were examined using regression analysis. RESULTS Overall, 14% (12 of 84) patients with a distal femur replacement had radiographic collapse of at least one of the modular tapers. Survivorship free from taper subsidence was 91% (95% CI 86% to 96%) at 10 years and 84% (95% CI 78% to 90%) at 20 years. All patients were in the distal femur replacement group. The median follow-up of patients with subsidence was 15 years (range 5 to 26). Fifty-eight percent (7 of 12) of patients had two junctions involved, 25% (3 of 12) had three junctions, and 17% (2 of 12) had one junction involved. All but one patient had subsidence in a single junction. The median time to subsidence was 15 years (range 4.5 to 24.0 years). The subsidence was progressive in all patients who demonstrated it. The taper junction subsidence was complete in 75% (9 of 12) of patients and partial in 25% (3 of 12). Univariate and multivariable regression analyses did not show that the risk factors we studied were associated with subsidence. Two patients with junction subsidence were revised, one for taper fracture and one during busing exchange for distal junction subsidence. CONCLUSION Taper damage with late and progressive subsidence of the intervening junction is not uncommon after distal femur replacement. The impact of such a complication is still unknown. Further studies should examine the long-term outcomes and correlate them with metal ion levels. LEVEL OF EVIDENCE Level III, therapeutic study.
Collapse
Affiliation(s)
- Anas Nooh
- College of Medicine, King AbdulAziz University, Jeddah, Saudi Arabia
- Division of Orthopaedic Surgery, McGill University, Montreal, Quebec, Canada
| | - Ahmed Aoude
- Division of Orthopaedic Surgery, McGill University, Montreal, Quebec, Canada
| | - Adam Hart
- Division of Orthopaedic Surgery, McGill University, Montreal, Quebec, Canada
| | - Michael Tanzer
- Division of Orthopaedic Surgery, McGill University, Montreal, Quebec, Canada
| | - Robert E Turcotte
- Division of Orthopaedic Surgery, McGill University, Montreal, Quebec, Canada
| |
Collapse
|
2
|
Dolinar D, Kocjančič B, Avsec K, Šetina Batič B, Kocijan A, Godec M, Sedlaček M, Debeljak M, Grant JT, Zupanc T, Jenko M. Characterization of Micro-Threaded Stem Taper Surfaces of Cementless Hip Endoprostheses. MATERIALS (BASEL, SWITZERLAND) 2024; 17:2751. [PMID: 38894016 PMCID: PMC11173811 DOI: 10.3390/ma17112751] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2024] [Revised: 05/26/2024] [Accepted: 05/29/2024] [Indexed: 06/21/2024]
Abstract
We investigated micro-threaded stem taper surface and its impact on premature failures, aseptic loosening, and infection in cementless hip endoprostheses. Our study focused on the fretting, and crevice corrosion of micro-threaded tapers, as well as the characterization of the microstructure and surface properties of two new and three retrieved Zweymüller stem tapers. The retrieved samples were selected and examined based on the head-stem taper interface being the sole source of modularity with a metallic component, specifically between the Ti alloy taper stem and the ceramic head. To determine the surface chemistry and microstructures of both new and retrieved hip endoprostheses stem taper titanium alloy, scanning -electron microscopy (SEM) was employed for morphological and microstructural analyses. Energy dispersive spectroscopy (EDS) was utilized for characterizing chemical element distribution, and electron backscattered diffraction (EBSD) was used for phase analysis. The roughness of the micro-threated stem tapers from different manufacturers was investigated using an optical profilometer, with standard roughness parameters Ra (average surface roughness) and Rz (mean peak to valley height of the roughness profile) being measured. Electrochemical studies revealed no fretting corrosion in retrieved stem tapers with ceramic heads. Consequently, three retrieved tapers and two new ones for comparison underwent potentiodynamic measurements in Hank's solution to determine the corrosion rate of new and retrieved stem taper surfaces. The results showed a low corrosion rate for both new and prematurely failed retrieved samples due to aseptic loosening. However, the corrosion rate was higher in infected and low-grade infected tapers. In conclusion, our study suggests that using ceramic heads reduces taper corrosion and subsequently decreases the incidence of premature failures in total hip arthroplasty.
Collapse
Affiliation(s)
- Drago Dolinar
- Department for Orthopaedic Surgery, University Medical Centre Ljubljana, Zaloška 9, 1000 Ljubljana, Slovenia; (D.D.); (B.K.); (K.A.); (T.Z.)
- Orthopaedic Surgery Chair, Faculty of Medicine, University of Ljubljana, Vrazov trg 2, 1000 Ljubljana, Slovenia
| | - Boštjan Kocjančič
- Department for Orthopaedic Surgery, University Medical Centre Ljubljana, Zaloška 9, 1000 Ljubljana, Slovenia; (D.D.); (B.K.); (K.A.); (T.Z.)
- Orthopaedic Surgery Chair, Faculty of Medicine, University of Ljubljana, Vrazov trg 2, 1000 Ljubljana, Slovenia
| | - Klemen Avsec
- Department for Orthopaedic Surgery, University Medical Centre Ljubljana, Zaloška 9, 1000 Ljubljana, Slovenia; (D.D.); (B.K.); (K.A.); (T.Z.)
- Orthopaedic Surgery Chair, Faculty of Medicine, University of Ljubljana, Vrazov trg 2, 1000 Ljubljana, Slovenia
| | - Barbara Šetina Batič
- Institute of Metals and Technology, Lepi pot 11, 1000 Ljubljana, Slovenia; (B.Š.B.); (A.K.); (M.G.); (M.S.)
| | - Aleksandra Kocijan
- Institute of Metals and Technology, Lepi pot 11, 1000 Ljubljana, Slovenia; (B.Š.B.); (A.K.); (M.G.); (M.S.)
| | - Matjaž Godec
- Institute of Metals and Technology, Lepi pot 11, 1000 Ljubljana, Slovenia; (B.Š.B.); (A.K.); (M.G.); (M.S.)
| | - Marko Sedlaček
- Institute of Metals and Technology, Lepi pot 11, 1000 Ljubljana, Slovenia; (B.Š.B.); (A.K.); (M.G.); (M.S.)
| | - Mojca Debeljak
- University Rehabilitation Institute Republic of Slovenia, Linhartova 51, 1000 Ljubljana, Slovenia;
| | - John T. Grant
- Research Institute, University of Dayton, Dayton, OH 45469, USA;
| | - Timon Zupanc
- Department for Orthopaedic Surgery, University Medical Centre Ljubljana, Zaloška 9, 1000 Ljubljana, Slovenia; (D.D.); (B.K.); (K.A.); (T.Z.)
| | - Monika Jenko
- MD-RI Institute for Materials Research in Medicine, Bohoričeva 5, 1000 Ljubljana, Slovenia
- MD Medicina, Sanatorium, Bohoričeva 5a, 1000 Ljubljana, Slovenia
| |
Collapse
|
3
|
Schlieker PJ, Morlock MM, Huber G. The force at the implant cannot be assessed by the mallet force-Unless supported by a model. PLoS One 2024; 19:e0303682. [PMID: 38758920 PMCID: PMC11101067 DOI: 10.1371/journal.pone.0303682] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Accepted: 04/29/2024] [Indexed: 05/19/2024] Open
Abstract
The implantation of uncemented prostheses requires the application of sufficient forces to achieve a press-fit of the implant in the bone. Excessive forces have to be omitted to limit bone damage. Force measurements along the force transmission path between mallet and implant are frequently used to investigate this trade-off. Placing a load cell at a position of interest (PoI), which might be the implant bone interface or the head taper junction, is technically challenging or even impossible so that nearby positions are chosen. Thus, a certain inertia and stiffness remain between the PoI and the sensor, and consequently the measured dynamic forces differ from those at the PoI. This experimental and numerical study aimed to investigate the amount of force reduction along the transmission path while joining femoral heads to stem tapers. Forces were measured in vitro at the tip of the mallet, directly above the polymer tip of the impactor and below the stem taper. Springs and masses were used to represent the responding tissue of a patient. A semi-empirical numerical model of the force transmission path was developed and validated in order to simulate a larger range of responding tissue properties than experimentally possible and to investigate the influence of different surgical instruments. A distinct attenuation was observed since the peak forces at the impactor reached 35% of the applied peak forces and 21% at the stem taper, respectively. The force curves were replicated with a median root mean square error of 3.8% of the corresponding mallet blow for the impactor and 3.6% for the stem. The force measurement position and the used surgical instruments have a strong influence on the measured forces. Consequently, the exact measurement conditions with regard to sensor positioning and used surgical instruments have to be specified and hence only studies with similar setups should be compared to avoid misestimation of the forces at the PoI. The proposed dynamic numerical model is a useful tool to calculate the impact of the chosen or changed mechanical parameters prior to executing experiments and also to extrapolate the effect of changing the applied forces to the resulting forces at the PoI.
Collapse
Affiliation(s)
- Peter J. Schlieker
- Institute of Biomechanics, TUHH Hamburg University of Technology, Hamburg, Germany
| | - Michael M. Morlock
- Institute of Biomechanics, TUHH Hamburg University of Technology, Hamburg, Germany
| | - Gerd Huber
- Institute of Biomechanics, TUHH Hamburg University of Technology, Hamburg, Germany
| |
Collapse
|
4
|
Darowski M, Ruehrmund L, Kluess D, Klinder A, Bader R, Mittelmeier W. The influence of surgical technique guidance and surgeon's experience on the femoral head assembly in total hip arthroplasty. Arch Orthop Trauma Surg 2024; 144:2391-2401. [PMID: 38563982 PMCID: PMC11093847 DOI: 10.1007/s00402-024-05282-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Accepted: 03/10/2024] [Indexed: 04/04/2024]
Abstract
INTRODUCTION The importance of the assembly procedure on the taper connection strength is evident. However, existent surgical technique guides frequently lack comprehensive and precise instructions in this regard. The aim of our experimental study was to evaluate the influence of the surgical technique guide on the femoral head assembly procedure in surgeons with differing levels of experience in total hip arthroplasty. MATERIALS AND METHODS Twenty-eight participants, divided into four groups based on their lifetime experience in total hip arthroplasty, conducted a femoral head assembly procedure in a simulated intraoperative environment before and after reviewing the surgical technique guide. Demographic information and the number of hammer blows were documented. Hammer velocity and impaction angle were recorded using an optical motion capturing system, while the impaction force was measured using a dynamic force sensor within the impactor. RESULTS We observed a high variation in the number of hammer blows, maximum force, and impaction angle. Overall, the number of hammer blows decreased significantly from 3 to 2.2 after reviewing the surgical technique guide. The only significant intragroup difference in the number of hammer blows was observed in the group with no prior experience in total hip arthroplasty. No correlation was found between individual factors (age, weight, height) or experience and the measured parameters (velocity, maximum force and angle). CONCLUSIONS The present study demonstrated a high variation in the parameters of the femoral head assembly procedure. Consideration of the surgical technique guide was found to be a limited factor among participants with varying levels of experience in total hip arthroplasty. These findings underline the importance of sufficient preoperative training, to standardize the assembly procedure, including impaction force, angle, and use of instruments.
Collapse
Affiliation(s)
- Martin Darowski
- Department of Orthopaedics, Rostock University Medical Center, Doberaner Straße 142, D-18057, Rostock, Germany.
| | - Leo Ruehrmund
- Department of Orthopaedics, Rostock University Medical Center, Doberaner Straße 142, D-18057, Rostock, Germany
| | - Daniel Kluess
- Department of Orthopaedics, Rostock University Medical Center, Doberaner Straße 142, D-18057, Rostock, Germany
| | - Annett Klinder
- Department of Orthopaedics, Rostock University Medical Center, Doberaner Straße 142, D-18057, Rostock, Germany
| | - Rainer Bader
- Department of Orthopaedics, Rostock University Medical Center, Doberaner Straße 142, D-18057, Rostock, Germany
| | - Wolfram Mittelmeier
- Department of Orthopaedics, Rostock University Medical Center, Doberaner Straße 142, D-18057, Rostock, Germany
| |
Collapse
|
5
|
Meier J, Hembus J, Bader R, Vogel D. Computer-based analysis of the taper connection strength of different revision head and adapter sleeve designs. BIOMED ENG-BIOMED TE 2024; 69:199-209. [PMID: 37698840 DOI: 10.1515/bmt-2023-0066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Accepted: 08/28/2023] [Indexed: 09/13/2023]
Abstract
OBJECTIVES Ceramic revision heads, equipped with titanium adapter sleeves, are used in femoral head revision in total hip arthroplasty to avoid ceramic fracture due to the damaged taper. METHODS A finite element analysis of the taper connection strength of revision heads with varying head diameters combined with adapter sleeves of different lengths was conducted. The influence of various assembly forces, head diameter, and length of the adapter sleeves was evaluated. For two combinations, the pattern of contact pressure was evaluated when applying a simplified joint load (3 kN, 45° load angle). Experimental validation was conducted with 36 mm heads and adapter sleeves in size S, as well as 28 mm heads and adapter sleeves in size XL. RESULTS The pull-off force increased with higher assembly forces. Using larger head diameters and adapter sleeves led to decreased pull-off forces, a reduced contact surface, and less contact pressure. The contact pressure showed significant peaks and a diagonal pattern under 45° angle loading when assembly forces were less than 4 kN, and larger adapter sleeves were utilized. CONCLUSION A sufficient assembly force should be ensured intraoperatively, especially with an increasing head diameter and adapter sleeve size, as lower assembly forces might lead to reduced taper connection strength.
Collapse
Affiliation(s)
- Johanna Meier
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| | - Jessica Hembus
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| | - Rainer Bader
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| | - Danny Vogel
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| |
Collapse
|
6
|
Hunger S, Rotsch C, Günther F, Drossel WG, Heyde CE. Influence of a Modified Procedure of Joining Ceramic Head and Adapter Sleeve on the Stem Taper in Revision: An Experimental Study. Bioengineering (Basel) 2024; 11:170. [PMID: 38391656 PMCID: PMC10886244 DOI: 10.3390/bioengineering11020170] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2023] [Revised: 02/01/2024] [Accepted: 02/07/2024] [Indexed: 02/24/2024] Open
Abstract
In revision operations, ceramic heads of modular hip implants can be replaced. As the surface of the stem taper can be damaged, additional adapter sleeves are applied. The components are usually connected manually by the surgeon in a one-step procedure by hammer impacts. In this study, we investigated a two-step joining procedure with reproducible impaction force. First, the adapter sleeve and head were joined quasi-statically with a force of 2 kN using an assembly device. In the second step, these components were applied to the stem taper using a pulse-controlled instrument. For reference, the joints were assembled according to standard conditions using a tensile testing machine. An average pull-off force of 1309 ± 201 N was achieved for the components joined by the instrument, and the average measured values for the components joined by the testing machine were 1290 ± 140 N. All specimens achieved a force >350 N when released and therefore met the acceptance criterion defined for this study. This study showed that a modified procedure in two steps with a defined force has a positive effect on the reproducibility of the measured joining forces compared to previous studies.
Collapse
Affiliation(s)
- Sandra Hunger
- Fraunhofer Institute for Machine Tools and Forming Technology IWU, 01187 Dresden, Germany
- Department of Orthopaedic, Trauma and Plastic Surgery Clinic, University of Leipzig Medical Center, 04103 Leipzig, Germany
| | - Christian Rotsch
- Fraunhofer Institute for Machine Tools and Forming Technology IWU, 01187 Dresden, Germany
- Department of Orthopaedic, Trauma and Plastic Surgery Clinic, University of Leipzig Medical Center, 04103 Leipzig, Germany
| | - Florian Günther
- Fraunhofer Institute for Machine Tools and Forming Technology IWU, 01187 Dresden, Germany
- Department of Orthopaedic, Trauma and Plastic Surgery Clinic, University of Leipzig Medical Center, 04103 Leipzig, Germany
| | - Welf-Guntram Drossel
- Fraunhofer Institute for Machine Tools and Forming Technology IWU, 01187 Dresden, Germany
- Institute for Machine Tools and Production Processes, Faculty of Mechanical Engineering, Chemnitz University of Technology, 09111 Chemnitz, Germany
| | - Christoph-Eckhard Heyde
- Department of Orthopaedic, Trauma and Plastic Surgery Clinic, University of Leipzig Medical Center, 04103 Leipzig, Germany
| |
Collapse
|
7
|
Rotsch C, Kemter-Esser K, Dohndorf J, Knothe M, Drossel WG, Heyde CE. Feasibility of a Shape-Memory-Alloy-Actuator System for Modular Acetabular Cups. Bioengineering (Basel) 2024; 11:75. [PMID: 38247952 PMCID: PMC10813518 DOI: 10.3390/bioengineering11010075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Revised: 12/29/2023] [Accepted: 01/05/2024] [Indexed: 01/23/2024] Open
Abstract
Hip implants have a modular structure which enables patient-specific adaptation but also revision of worn or damaged friction partners without compromising the implant-bone connection. To reduce complications during the extraction of ceramic inlays, this work presents a new approach of a shape-memory-alloy-actuator which enables the loosening of ceramic inlays from acetabular hip cups without ceramic chipping or damaging the metal cup. This technical in vitro study exam-ines two principles of heating currents and hot water for thermal activation of the shape-memory-alloy-actuator to generate a force between the metal cup and the ceramic inlay. Mechanical tests concerning push-in and push-out forces, deformation of the acetabular cup according to international test standards, and force generated by the actuator were generated to prove the feasibility of this new approach to ceramic inlay revision. The required disassembly force for a modular acetabular device achieved an average value of 602 N after static and 713 N after cyclic loading. The actuator can provide a push-out force up to 1951 N. In addition, it is shown that the necessary modifications to the implant modules for the implementation of the shape-memory-actuator-system do not result in any change in the mechanical properties compared to conventional systems.
Collapse
Affiliation(s)
- Christian Rotsch
- Fraunhofer Institute for Machine Tools and Forming Technology IWU, 01187 Dresden, Germany; (K.K.-E.); (J.D.); (W.-G.D.)
- University of Leipzig Medical Center, Orthopaedic, Trauma and Plastic Surgery Clinic, University of Leipzig, 04103 Leipzig, Germany;
| | - Karoline Kemter-Esser
- Fraunhofer Institute for Machine Tools and Forming Technology IWU, 01187 Dresden, Germany; (K.K.-E.); (J.D.); (W.-G.D.)
| | - Johanna Dohndorf
- Fraunhofer Institute for Machine Tools and Forming Technology IWU, 01187 Dresden, Germany; (K.K.-E.); (J.D.); (W.-G.D.)
- Institute of Biomedical Engineering, TUD Dresden University of Technology, 01307 Dresden, Germany
| | - Marcel Knothe
- IMA Materialforschung und Anwendungstechnik GmbH, 01099 Dresden, Germany;
| | - Welf-Guntram Drossel
- Fraunhofer Institute for Machine Tools and Forming Technology IWU, 01187 Dresden, Germany; (K.K.-E.); (J.D.); (W.-G.D.)
- Professorship Adaptronics and Lightweight Design in Production, Chemnitz University of Technology, 09107 Chemnitz, Germany
| | - Christoph-Eckhard Heyde
- University of Leipzig Medical Center, Orthopaedic, Trauma and Plastic Surgery Clinic, University of Leipzig, 04103 Leipzig, Germany;
| |
Collapse
|
8
|
Hunger S, Seidler A, Rotsch C, Heyde CE, Drossel WG. Evaluating the Feasibility and Reproducibility of a Novel Insertion Method for Modular Acetabular Ceramic Liners. Bioengineering (Basel) 2023; 10:1180. [PMID: 37892910 PMCID: PMC10604853 DOI: 10.3390/bioengineering10101180] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2023] [Revised: 09/24/2023] [Accepted: 10/03/2023] [Indexed: 10/29/2023] Open
Abstract
Modern hip implants have a modular design. In case of wear or other damage it allows surgeons to change the tribological partners, i.e., the acetabular liner and femoral ball. In both revision and primary surgery, the secure joining of the implant components is important for the success of the operation. The two components, namely the ceramic liner and hip cup, are connected via a conical press connection and should be concentrically aligned to avoid chipping. Malseated liners can reduce the life span in situ. The amount of the joining force, which is usually applied via a hammer, depends on the surgeon. In this study, an alternative joining method for acetabular ceramic liners in hip cups was investigated, which intends to make the process more reproducible and thus safer. For this purpose, a handpiece was used to apply a defined force impulse of 4 kN. For the concentric alignment of a ceramic liner in the hip cup, an adapter was developed based on findings via a qualitative finite element (FE) analysis. Insertion and pushout tests of the acetabular cup-liner connection were performed in the laboratory with the new instrument (handpiece with the connected adapter) to evaluate the functionality of the instrument and the reproducibility of the new insertion method. For comparison, liners and acetabular cups were joined using a testing machine according to the standard. The presented results demonstrate the technical proof-of-concept of the new joining method under laboratory conditions. They meet the acceptance criteria of established manufacturers, which proves the equivalency to proven methods for joining modular implant components. To verify the improvement of the new joining method compared to the conventionally used joining method, an application-oriented study with different surgeons and the new joining instrument under clinical conditions is necessary.
Collapse
Affiliation(s)
- Sandra Hunger
- Fraunhofer Institute for Machine Tools and Forming Technology IWU, 01187 Dresden, Germany; (A.S.); (C.R.); (W.-G.D.)
- Department of Orthopaedic, Trauma and Plastic Surgery Clinic, University of Leipzig Medical Center, 04103 Leipzig, Germany;
| | - Alexander Seidler
- Fraunhofer Institute for Machine Tools and Forming Technology IWU, 01187 Dresden, Germany; (A.S.); (C.R.); (W.-G.D.)
- Institute of Machine Elements and Machine Design, Faculty of Mechanical Science and Engineering, Dresden University of Technology, 01062 Dresden, Germany
| | - Christian Rotsch
- Fraunhofer Institute for Machine Tools and Forming Technology IWU, 01187 Dresden, Germany; (A.S.); (C.R.); (W.-G.D.)
- Department of Orthopaedic, Trauma and Plastic Surgery Clinic, University of Leipzig Medical Center, 04103 Leipzig, Germany;
| | - Christoph-Eckhard Heyde
- Department of Orthopaedic, Trauma and Plastic Surgery Clinic, University of Leipzig Medical Center, 04103 Leipzig, Germany;
| | - Welf-Guntram Drossel
- Fraunhofer Institute for Machine Tools and Forming Technology IWU, 01187 Dresden, Germany; (A.S.); (C.R.); (W.-G.D.)
- Institute for Machine Tools and Production Processes, Faculty of Mechanical Engineering, Chemnitz University of Technology, 09111 Chemnitz, Germany
| |
Collapse
|
9
|
Gustafson JA, Mell S, Levine BR, Pourzal R, Lundberg HJ. Interaction of surface topography and taper mismatch on head-stem modular junction contact mechanics during assembly in modern total hip replacement. J Orthop Res 2023; 41:418-425. [PMID: 35488727 PMCID: PMC9617811 DOI: 10.1002/jor.25357] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Revised: 04/11/2022] [Accepted: 04/28/2022] [Indexed: 02/04/2023]
Abstract
Implant failure due to fretting corrosion at the head-stem modular junction is an increasing problem in modular total hip arthroplasty. The effect of varying microgroove topography on modular junction contact mechanics has not been well characterized. The aim of this study was to employ a novel, microgrooved finite element (FEA) model of the hip taper interface and assess the role of microgroove geometry and taper mismatch angle on the modular junction mechanics during assembly. A two-dimensional, axisymmetric FEA model was created using a modern 12/14 taper design of a CoCrMo femoral head taper and Ti6Al4V stem taper. Microgrooves were modeled at the contacting interface of the tapers and varied based on height and spacing measurements obtained from a repository of measured retrievals. Additionally, taper angular mismatch between the head and stem was varied to simulate proximal- and distal-locked engagement. Forty simulations were conducted to parametrically evaluate the effects of microgroove surface topography and angular mismatch on predicted contact area, contact pressure, and equivalent plastic strain. Multiple linear regression analysis was highly significant (p < 0.001; R2 > 0.74) for all outcome variables. The regression analysis identified microgroove geometry on the head taper to have the greatest influence on modular junction contact mechanics. Additionally, there was a significant second order relationship between both peak contact pressure (p < 0.001) and plastic strain (p < 0.001) with taper mismatch angle. These modeling techniques will be used to identify the implant parameters that maximize taper interference strength via large in-silico parametric studies.
Collapse
Affiliation(s)
| | - Steven Mell
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Brett R. Levine
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Robin Pourzal
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Hannah J. Lundberg
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois
| |
Collapse
|
10
|
Abdelaal AM, Khalifa AA. A disposable plastic syringe helps protect the femoral stem trunnion during acetabular cup only revision: A technical note. JOURNAL OF MUSCULOSKELETAL SURGERY AND RESEARCH 2022; 7:49-51. [DOI: 10.25259/jmsr_134_2022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2023]
Abstract
Up to 25% of revision total hip arthroplasty (RTHA) requires acetabular cup only revision, during which the femoral stem is left in place. The metal retractors and instruments used to obtain the required exposure during revision surgery with the femoral stem in place could damage the trunnion, which could lead to further failure due to trunnionosis. Hence, protection of the trunnion during surgery is paramount. Here, we describe the use of a disposable plastic syringe to cover the trunnion during acetabular cup only RTHA, in which we consider an effective and cheap effective technique.
Collapse
Affiliation(s)
- Ahmed M. Abdelaal
- Department of Orthopedic and Traumatology, Assiut University Hospital, Assiut University, Assiut, Egypt
| | - Ahmed A. Khalifa
- Department of Orthopedics, Qena Faculty of Medicine and University Hospital, South Valley University, Qena, Egypt,
| |
Collapse
|
11
|
Dun S, Lim BH, Swope SW, Whitaker DR. A novel method to improve femoral head and stem taper stability intraoperatively in total hip arthroplasty - a proof of concept study. Orthop Traumatol Surg Res 2022; 108:103284. [PMID: 35470121 DOI: 10.1016/j.otsr.2022.103284] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Revised: 11/29/2021] [Accepted: 01/04/2022] [Indexed: 02/03/2023]
Abstract
BACKGROUND Mechanically assisted crevice corrosion (MACC) has been associated with the compromised durability and fixation of modular total hip implants, adverse reaction of local tissue, and other undesirable clinical outcomes in total hip arthroplasty (THA). MACC is primarily caused by the relative motion between the femoral head and stem. To minimize the relative motion the taper connection between the two components must be strong enough. The current study addressed the following questions: (1) Does increasing the mass of the femoral stem improve the taper connection strength intraoperatively? (2) Does increasing the mass of the femoral stem reduce the risk of periprosthetic tissue damage intraoperatively? HYPOTHESIS Increasing the mass of the femoral stem improve the taper connection strength intraoperatively. MATERIALS AND METHODS During the experiment, femoral heads were impacted onto the stem tapers with and without an additional weight attached to the stem. The femoral heads were then pulled off to investigate the strength of the taper connection. The stem displacement and acceleration at impaction were also measured to evaluate the risk of periprosthetic tissue damage. RESULTS The results showed that the pull-off force was increased by 24% (p=0.011, n=6) when an additional weight was attached to the stem. The additional weight also reduced the maximum stem acceleration and maximum stem displacement by 37% (p<0.001, n=6) and 14% (p=0.094, n=6), respectively. DISCUSSION These findings suggest that the femoral head and stem taper connection strength can be significantly improved and the risk of periprosthetic tissue damage significantly reduced intraoperatively by attaching an additional weight to the stem to increase its mass. LEVEL OF EVIDENCE III, comparative in vitro mechanical investigation.
Collapse
Affiliation(s)
- Shouchen Dun
- DePuy Synthes Joint Reconstruction, 700 Orthopaedic Drive, Warsaw, IN 46581, USA.
| | - Boon Him Lim
- DePuy Synthes Joint Reconstruction, 700 Orthopaedic Drive, Warsaw, IN 46581, USA
| | - Stephen W Swope
- DePuy Synthes Joint Reconstruction, 700 Orthopaedic Drive, Warsaw, IN 46581, USA
| | - Dustin R Whitaker
- DePuy Synthes Joint Reconstruction, 700 Orthopaedic Drive, Warsaw, IN 46581, USA
| |
Collapse
|
12
|
Hornung AL, Hall DJ, Je M, Wright JL, Nicholson GP, Garrigues GE, Pourzal R. Do total shoulder arthroplasty implants corrode? J Shoulder Elbow Surg 2022; 31:2381-2391. [PMID: 35671932 PMCID: PMC9588611 DOI: 10.1016/j.jse.2022.04.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Revised: 04/12/2022] [Accepted: 04/24/2022] [Indexed: 02/01/2023]
Abstract
BACKGROUND Total shoulder arthroplasty (TSA) has become the gold-standard treatment to relieve joint pain and disability in patients with glenohumeral osteoarthritis who do not respond to conservative treatment. An adverse reaction to metal debris released due to fretting corrosion has been a major concern in total hip arthroplasty. To date, it is unclear how frequently implant corrosion occurs in TSA and whether it is a cause of implant failure. This study aimed to characterize and quantify corrosion and fretting damage in a single anatomic TSA design and to compare the outcomes to the established outcomes of total hip arthroplasty. METHODS We analyzed 21 surgically retrieved anatomic TSAs of the same design (Tornier Aequalis Pressfit). The retrieved components were microscopically examined for taper corrosion, and taper damage was scored. Head and stem taper damage was quantitatively measured with a non-contact optical coordinate-measuring machine. In selected cases, damage was further characterized at high magnifications using scanning electron microscopy. Energy-dispersive x-ray spectroscopy and metallographic evaluations were performed to determine underlying alloy microstructure and composition. Comparisons between groups with different damage features were performed with independent-samples t tests; Mann-Whitney tests and multivariate linear regression were conducted to correlate damage with patient factors. The level of statistical significance was set at P < .05. RESULTS The average material loss for head and stem tapers was 0.007 mm3 and 0.001 mm3, respectively. Material loss was not correlated with sex, age, previous implant, or time in situ (P > .05). We observed greater volume loss in head tapers compared with stem tapers (P = .002). Implants with evidence of column damage had larger volumetric material loss than those without such evidence (P = .003). Column damage aligned with segregation bands within the alloy (preferential corrosion sites). The average angular mismatch was 0.03° (standard deviation, 0.0668°), with negative values indicating distal engagement and positive values indicating proximal engagement. Implants with proximal engagement were significantly more likely to have column damage than those with distal engagement (P = .030). DISCUSSION This study has shown not only that the metal components of TSA implants can corrode but also that the risk of corrosion can be reduced by (1) eliminating preferential corrosion sites and (2) ensuring distal engagement to prevent fluid infiltration into the modular junction.
Collapse
Affiliation(s)
- Alexander L Hornung
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA.
| | - Deborah J Hall
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Mable Je
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Jennifer L Wright
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Gregory P Nicholson
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA; Midwest Orthopedics at Rush, Chicago, IL, USA
| | - Grant E Garrigues
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA; Midwest Orthopedics at Rush, Chicago, IL, USA
| | - Robin Pourzal
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| |
Collapse
|
13
|
Fallahnezhad K, Feyzi M, Hashemi R, Taylor M. The Role of the Assembly Force in the Tribocorrosion Behaviour of Hip Implant Head-Neck Junctions: An Adaptive Finite Element Approach. Bioengineering (Basel) 2022; 9:629. [PMID: 36354540 PMCID: PMC9687484 DOI: 10.3390/bioengineering9110629] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Revised: 10/20/2022] [Accepted: 10/23/2022] [Indexed: 09/13/2023] Open
Abstract
The cyclic loading, in the corrosive medium of the human body, results in tribocorrosion at the interface of the head-neck taper junction of hip implants. The resulting metal ions and wear debris adversely affect the local tissues. The force applied by surgeons to assemble the junction has proven to play a major role in the mechanics of the taper junction which, in turn, can influence the tribocorrosion damage. Recently, finite element method has been used to predict the material loss at the head-neck interface. However, in most finite element studies, the contribution of electrochemical corrosion has been ignored. Therefore, a detailed study to investigate the influence of the assembly force on the tribocorrosive behaviour of the head-neck junction, which considers both the mechanical and chemical material removal, is of paramount interest. In this study, a finite-element-based algorithm was used to investigate the effect of assembly force on the tribocorrosion damage at the junction interface, for over four million cycles of simulated level gait. The patterns of the material removal in the modelling results were compared with the damage patterns observed in a group of retrieved modular hip implants. The results of this study showed that for different cases, chemical wear was in the range of 25-50% of the total material loss, after four million cycles. A minimum assembly force (4 kN for the studied cases) was needed to maintain the interlock in the junction. The computational model was able to predict the damage pattern at the retrieved head-neck interface.
Collapse
Affiliation(s)
- Khosro Fallahnezhad
- Medical Device Research Institute, College of Science and Engineering, Flinders University, 1284 South Road, Clovelly Park, SA 5042, Australia
| | | | | | | |
Collapse
|
14
|
Taper corrosion in total hip arthroplasty – How to assess and which design features are crucial? J Mech Behav Biomed Mater 2022; 133:105307. [DOI: 10.1016/j.jmbbm.2022.105307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Revised: 05/28/2022] [Accepted: 05/30/2022] [Indexed: 11/21/2022]
|
15
|
Godoy M, Gustafson JA, Hertzler JS, Bischoff JE, Pourzal R, Lundberg HJ. Model validation for estimating taper microgroove deformation during total hip arthroplasty head-neck assembly. J Biomech 2022; 140:111172. [PMID: 35696772 PMCID: PMC9801958 DOI: 10.1016/j.jbiomech.2022.111172] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Revised: 03/25/2022] [Accepted: 05/31/2022] [Indexed: 01/03/2023]
Abstract
Total hip arthroplasty (THA) failure and the need for revision surgery can result from fretting-corrosion damage of the head-neck modular taper junctions. Prior work has shown that implant geometry, such as microgrooves, influences damage on retrieved implants. Microgroove deformation within the modular taper junction occurs when the female head taper meets the male stem taper during THA surgical procedure. The objective of this work was to validate microgroove deformation after head-neck THA assembly as calculated by finite element analysis (FEA). Four 28 mm CoCrMo head tapers and four Ti6Al4V stem tapers were scanned via white light interferometry. Heads were assembled onto stem tapers until 6kN reaction force was achieved, followed by head removal using a cut-off machine. The stem tapers were then rescanned and analyzed. Simultaneously, a 2D axisymmetric FEA model was developed and assembled per implant geometries and experimental data. For experiments and FEA, the mean change in microgroove height was 1.23 µm and 1.40 µm, respectively. The largest microgroove height change occurred on the proximal stem taper due to the conical angles of the head and stem tapers. FEA showed that the head-stem assembly induced high stresses and microgroove peaks flattening. 76-89% and 91-100% of the microgrooves in the experiments and FEA, respectively, showed height changes along the contact length of the stem taper. A validated FEA model of THA head-neck modular junction contact mechanics is essential to identifying implant geometries and surface topographies that can potentially minimize the risk of fretting and fretting-corrosion at modular junctions.
Collapse
Affiliation(s)
- Michael Godoy
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | | | | | | | - Robin Pourzal
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Hannah J. Lundberg
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| |
Collapse
|
16
|
Bishop NE, Wright P, Preutenborbeck M. A parametric numerical analysis of femoral stem impaction. PLoS One 2022; 17:e0268561. [PMID: 35594265 PMCID: PMC9122192 DOI: 10.1371/journal.pone.0268561] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Accepted: 05/02/2022] [Indexed: 11/19/2022] Open
Abstract
Press-fitted implants are implanted by impaction to ensure adequate seating, but without overloading the components, the surgeon, or the patient. To understand this interrelationship a uniaxial discretised model of the hammer/introducer/implant/bone/soft-tissues was developed. A parametric analysis of applied energy, component materials and geometry, and interactions between implant and bone and between bone and soft-tissues was performed, with implant seating and component stresses as outcome variables. To reduce the impaction effort (energy) required by the surgeon for implant seating and also reduce stresses in the hardware the following outcomes were observed: Reduce energy per hit with more hits / Increase hammer mass / Decrease introducer mass / Increase implant-bone resistance (eg stem roughness). Hardware stiffness and patient mechanics were found to be less important and soft tissue forces, due to inertial protection by the bone mass, were so low that their damage would be unlikely. This simple model provides a basic understanding of how stress waves travel through the impacted system, and an understanding of their relevance to implantation technique and component design.
Collapse
Affiliation(s)
- Nicholas E. Bishop
- Hamburg University of Applied Sciences, Faculty of Life Sciences, Hamburg, Germany
- * E-mail:
| | | | | |
Collapse
|
17
|
Parametric analysis of the effect of impaction load on the stability of head-neck junction in total hip arthroplasty. Clin Biomech (Bristol, Avon) 2022; 94:105633. [PMID: 35364404 DOI: 10.1016/j.clinbiomech.2022.105633] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 03/15/2022] [Accepted: 03/22/2022] [Indexed: 02/07/2023]
Abstract
BACKGROUND Tribocorrosion at head-neck interface is one of the main causes leading to the failure of hip implants in total hip arthroplasty. Impaction load has been acknowledged as one of the key factors influencing the stability of the taper junction. It is understood that the magnitude of impaction force differs from the surgeon to surgeon in primary total hip arthroplasty or revision. Clinically, it is sufficient enough to keep the male and female tapers inseparable utilizing a low impaction, which seems to contradict previous researches. The objective of this study was to investigate the effect of impaction loads on the stability of taper junction during assembly and gaits. METHODS A finite element model with 12/14 taper and the taper mismatch of 4' was developed for investigation. The impaction force profiles were collected from surgeon as the inputs, and then the contact mechanics over one or multiple gaits was further analyzed and validated utilizing hip simulator test. FINDINGS Impaction force ranging from 200 to 2000 N could provide the same taper connection effect after the first gait due to the secondary seating. As for impaction loads of 3000 N and above, an increased impaction force would lead to the tighter taper connection. INTERPRETATION The effect of impaction load on the stability of head-neck junction is a piecewise function, indicating that the stability of taper junction is not affected by different impaction loads and tends to be consistent while its magnitude is below the threshold. Instead, the stability of taper junction is positively correlated with impaction force.
Collapse
|
18
|
Qurashi S, Pelletier MH, Wang T, Bramich N, Chinnappa J, Walsh WR. Stand up! Are normal weight-bearing forces sufficient for a 12/14 Morse taper locking in total hip arthroplasty? Hip Int 2022; 32:231-236. [PMID: 33081513 DOI: 10.1177/1120700020967000] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND The aim of this study was to investigate total hip arthroplasty (THA) Morse taper pull-off strengths after impaction prior to cyclical loading compared to cyclical loading alone. The practical relevance of the experiment is to provide a perspective on what may be clinically satisfactory taper assembly given the spectrum of head tapping patterns used by surgeons, as well as compare traditional impaction performed in standard THA with alternate methods of taper engagement such as 'in situ assembly' used in micro-invasive techniques. METHODS 36 taper constructs utilising a combination of cobalt-chrome alloy and ceramic-titanium alloy junctions were investigated in vitro in wet and dry conditions with cyclical loading of the constructs. Taper disengagement strengths with and without impaction were compared. Secondary investigation of the surface roughness of the heads and tapers was also assessed. RESULTS An impaction to a wet taper resulted in a greater pull off force compared to a dry taper with a CoCr head and taper combination. Impacting the head and dryness of the taper did not affect pull off forces of a ceramic femoral head on titanium taper. Pulling a head off a taper significantly alters the head surface roughness. CONCLUSION Impaction of a taper does not provide any benefit over cyclical loading of a taper assembly alone for pull-off strength.
Collapse
Affiliation(s)
- Suleman Qurashi
- Surgical & Orthopaedic Research Laboratories, Prince of Wales Clinical School University of New South Wales, Sydney, NSW, Australia.,The Hip & Knee Clinic at Harbour City Orthopaedics, Sydney, NSW, Australia.,Nepean Hospital, Kingswood, NSW Australia
| | - Matthew H Pelletier
- Surgical & Orthopaedic Research Laboratories, Prince of Wales Clinical School University of New South Wales, Sydney, NSW, Australia
| | - Tian Wang
- Surgical & Orthopaedic Research Laboratories, Prince of Wales Clinical School University of New South Wales, Sydney, NSW, Australia
| | - Nicholas Bramich
- Surgical & Orthopaedic Research Laboratories, Prince of Wales Clinical School University of New South Wales, Sydney, NSW, Australia
| | - Jason Chinnappa
- Surgical & Orthopaedic Research Laboratories, Prince of Wales Clinical School University of New South Wales, Sydney, NSW, Australia
| | - William R Walsh
- Surgical & Orthopaedic Research Laboratories, Prince of Wales Clinical School University of New South Wales, Sydney, NSW, Australia
| |
Collapse
|
19
|
Wight CM, Schemitsch EH. In vitro testing for hip head-neck taper tribocorrosion: A review of experimental methods. Proc Inst Mech Eng H 2022; 236:9544119221074582. [PMID: 35139678 PMCID: PMC8915230 DOI: 10.1177/09544119221074582] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
In vitro test methods are challenged by the multi-factorial nature of head-neck taper connection tribocorrosion due to the consequences of simplification. Incorrect study design and misinterpretation of results has led to contradictory findings regarding important factors affecting head-neck taper tribocorrosion. This review seeks to highlight important considerations when developing in vitro test methods, to help researchers strengthen their study design and analyze the implications of others' design decisions. The advantages, disadvantages, limitations and procedural considerations for finite element analyses, electrochemical studies and in vitro simulations related to head-neck taper connection tribocorrosion are discussed. Finite element analysis offers an efficient method for studying large ranges of mechanical parameters. However, they are limited by neglecting electrochemical, biological and fluid flow factors. Electrochemical studies may be preferred if these factors are considered important. Care must be taken in interpreting data from electrochemical studies, particularly when different materials are compared. Differences in material valence and toxicity affect clinical translation of electrochemical studies' results. At their most complex, electrochemical studies attempt to simulate all aspects of headneck taper connection tribocorrosion in a bench top study. Effective execution requires in-depth knowledge of the tribocorrosion phenomenon, the involved mechanisms, and their measures such that each study design decision is fully informed.
Collapse
Affiliation(s)
- Christian M Wight
- Institute of Biomaterial and Biomedical Engineering, University of Toronto, Toronto, ON, Canada
| | - Emil H Schemitsch
- Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine and Dentistry, The University of Western Ontario, London, ON, Canada
| |
Collapse
|
20
|
Wade A, Webster F, Beadling AR, Bryant MG. Importance of surgical assembly technique on the engagement of 12/14 modular tapers. Proc Inst Mech Eng H 2022; 236:158-168. [PMID: 34693823 PMCID: PMC8688978 DOI: 10.1177/09544119211053066] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Accepted: 09/19/2021] [Indexed: 11/30/2022]
Abstract
Fretting-corrosion at the modular taper junction in total hip replacements (THR), leading to implant failure, has been identified as a clinical concern and has received increased interest in recent years. There are many parameters thought to affect the performance of the taper junction, with the assembly process being one of the few consistently identified to have a direct impact. Despite this, the assembly process used by surgeons during THR surgery differs from a suggested 'ideal' process. For example, taper junctions of cutting tools should be pushed together rather than impacted, while ensuring as much concentricity as possible between the male and female taper and loading axis. This study devised six simple assembly methodologies to investigate how surgical variations affect the success of the compressive fit achieved at the taper interface compared to a controlled assembly method, designed to represent a more 'ideal' scenario. Key findings from this study suggest that a more successful and repeatable engagement can be achieved by quasi-statically loading the male and female taper concentrically with the loading axis. This was shown by a greater disassembly to assembly force ratio of 0.626 ± 0.07 when assembled using the more 'ideal' process, compared to 0.480 ± 0.05 when using a method closer to that used by a surgeon intraoperatively. Findings from this study can be used to help inform new surgical instrumentation and an improved surgical assembly method.
Collapse
Affiliation(s)
- A Wade
- School of Mechanical Engineering, Institute of Functional Surfaces, University of Leeds, Leeds, UK
| | - F Webster
- School of Mechanical Engineering, Institute of Functional Surfaces, University of Leeds, Leeds, UK
| | - AR Beadling
- School of Mechanical Engineering, Institute of Functional Surfaces, University of Leeds, Leeds, UK
| | - MG Bryant
- School of Mechanical Engineering, Institute of Functional Surfaces, University of Leeds, Leeds, UK
| |
Collapse
|
21
|
Mai PT, Bormann T, Müller U, Kretzer JP, Gibmeier J. Effect of surface topography and residual stress on the taper connection stability in total hip arthroplasty. J Mech Behav Biomed Mater 2022; 128:105119. [DOI: 10.1016/j.jmbbm.2022.105119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Revised: 01/10/2022] [Accepted: 02/03/2022] [Indexed: 11/26/2022]
|
22
|
Kim HS, Park JW, Lee YK, Porporati AA, Ha YC, Koo KH. Surgeons’ Awareness and Impaction Technique of a Ceramic Liner into a Metal Shell. Clin Orthop Surg 2022; 14:191-195. [PMID: 35685977 PMCID: PMC9152890 DOI: 10.4055/cios21102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/25/2021] [Revised: 08/08/2021] [Accepted: 08/08/2021] [Indexed: 11/17/2022] Open
Abstract
Background In ceramic-on-ceramic total hip arthroplasty, firm locking is necessary between a ceramic liner and an acetabular metal shell to prevent dissociation of the liner from the metal shell. We evaluated surgeons’ awareness of the technique for inserting the ceramic liner and measured the impaction force applied by surgeons during the insertion of the ceramic liner. Methods To evaluate the awareness, we conducted a survey using a questionnaire including techniques for ceramic liner insertion. The impaction force was measured using an impaction simulator in 224 surgeons. Results Most surgeons answered that they cleaned and dried up the inner surface of the metal shell before inserting a ceramic liner (96.4% and 86.2%, respectively), and 74.6% checked the correct seating of the ceramic liner. However, only 23.2% correctly answered that a minimum of 2kN (a light strike) was necessary to obtain a sufficient fit between the metal shell and the ceramic liner. The impaction force was weaker than 2 kN in 9.4% of the surgeons. Conclusions Education about the adequate impaction force to obtain a firm fit of the ceramic liner is necessary for surgeons who perform total hip arthroplasty using ceramic-on-ceramic bearings.
Collapse
Affiliation(s)
- Hong Seok Kim
- Department of Orthopedic Surgery, Seoul National University Bundang Hospital, Seongnam, Korea
| | - Jung-Wee Park
- Department of Orthopedic Surgery, Seoul National University Bundang Hospital, Seongnam, Korea
| | - Young-Kyun Lee
- Department of Orthopedic Surgery, Seoul National University Bundang Hospital, Seongnam, Korea
| | | | - Yong-Chan Ha
- Department of Orthopaedic Surgery, Chung-Ang University College of Medicine, Seoul, Korea
| | - Kyung-Hoi Koo
- Department of Orthopedic Surgery, Seoul National University Bundang Hospital, Seongnam, Korea
| |
Collapse
|
23
|
Diaz-Lopez R, Wen P, Shelton J. Influence of taper design and loading on taper micromotion. J Mech Behav Biomed Mater 2022; 128:105106. [DOI: 10.1016/j.jmbbm.2022.105106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Revised: 10/05/2021] [Accepted: 01/25/2022] [Indexed: 11/24/2022]
|
24
|
Bishop NE, Wright P, Dudrey-Harvey C, Preutenborbeck M. A model of uniaxial implant seating by impaction. Med Eng Phys 2021; 97:47-55. [PMID: 34756338 DOI: 10.1016/j.medengphy.2021.09.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Revised: 09/27/2021] [Accepted: 09/30/2021] [Indexed: 11/16/2022]
Abstract
Implants anchored by press-fit are predominantly implanted by impaction. This method allows sufficiently high forces to be generated easily by the surgeon. Suitable impaction should provide adequate implant seating without damaging the patient (tissues), the implant and implantation system, or the surgeon. However, issues have been documented for all of these factors. In this study a model to predict implant seating is developed, given an applied impaction impulse, the mass of the accelerated components and the push-in resistance force. The model was validated against experimental data for a contemporary femoral stem implanted in a polyurethane foam surrogate for bone, with the input parameters varied. The model tended to overestimate seating but represented seating patterns well. The model can be used to estimate implant seating using easily measured parameters and could be useful in the design of implantation systems, and in optimising impaction strategies.
Collapse
Affiliation(s)
- N E Bishop
- Hamburg University of Applied Sciences, Hamburg, Germany.
| | - P Wright
- DePuy Synthes, Leeds, United Kingdom
| | | | | |
Collapse
|
25
|
Herbster M, Berth A, Märtens N, Robra M, Welzel F, Dallmann F, Lohmann CH, Halle T, Bertrand J, Döring J. Intraoperative assembly of anatomical shoulder prosthesis frequently results in malalignment of the modular taper junction. J Orthop Res 2021; 39:2485-2496. [PMID: 33368644 DOI: 10.1002/jor.24975] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/29/2020] [Revised: 12/08/2020] [Accepted: 12/14/2020] [Indexed: 02/04/2023]
Abstract
Anatomical shoulder arthroplasties (ASA) may fail because of micromotion at the modular taper junction causing wear due to fretting. Sufficient taper strength can reduce micromotion and potential reasons for failure. However, there are no normative standards for a safe assembly process performed intraoperatively by the surgeon. The purpose of this study is to determine the effect of common intraoperative assembly strategies and to identify critical influencing factors on taper stability. ASA with standard and stemless humeral component in combination with concentric Al2 O3 heads and eccentric CoCr28Mo6 alloyed humeral heads were tested. Taper angles and surface roughness were determined. Force magnitudes and impact directions were recorded using a sensorized head impactor and a three-dimensional force measuring platform. Subsequently, the axial pull-off forces were measured and taper engagement areas were macroscopically evaluated. In comparison to standard stem tapers that were impacted with an assembly device, stemless tapers were impacted into the artificial bone with significantly lower forces. Taper strength correlates to maximum impact force and was higher for CoCr28Mo6 heads with a mean pull-off ratio of 0.56 than for Al2 O3 heads with 0.37. Interestingly, all tapers showed an asymmetric clamping behavior, due to tilting during impaction. This is caused by the variation of the resulting force vector and further promoted by humeral head eccentricity. Assembly technique markedly influences the force magnitude, impact direction, impulse, and consequently taper strength. The resulting force vector and head eccentricity were identified as potential risk factors for taper malalignment.
Collapse
Affiliation(s)
- Maria Herbster
- Institute of Materials and Joining Technology, Otto-von-Guericke University, Magdeburg, Germany
| | - Alexander Berth
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Nicole Märtens
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Marcel Robra
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Florian Welzel
- GFE-Gesellschaft für Fertigungstechnik und Entwicklung Schmalkalden e.V., Schmalkalden, Germany
| | | | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Thorsten Halle
- Institute of Materials and Joining Technology, Otto-von-Guericke University, Magdeburg, Germany
| | - Jessica Bertrand
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Joachim Döring
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| |
Collapse
|
26
|
Smith SM, Gilbert JL. Interfacial compliance, energy dissipation, frequency effects, and long-term fretting corrosion performance of Ti-6Al-4V/CoCrMo interfaces. J Biomed Mater Res A 2021; 110:409-423. [PMID: 34402604 DOI: 10.1002/jbm.a.37299] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2021] [Revised: 05/14/2021] [Accepted: 08/05/2021] [Indexed: 11/10/2022]
Abstract
Fretting corrosion in modular orthopedic implants is a well-documented process that may be associated with adverse local tissue reactions, pain, and revisions. Engineering modular junction interfaces to withstand applied fretting motion without surface abrasion could prevent implant degradation and surface damage. Previous work on geometrically modified Ti-6Al-4V/CoCrMo interfaces with increased compliance showed reduced fretting currents and surface damage during short term, variable-load in vitro testing. This study assesses the same interfaces under long-term conditions using an in vitro pin-on-disk fretting corrosion test apparatus. Preliminary variable-load frequency testing of typical control pin geometries showed a frequency-dependent current response, with underlying contact conditions of metal-metal interfaces that remained unchanged. One-million-cycle testing showed diminished fretting currents in all groups by 5 × 105 cycles, but consistently lower currents in the high-compliance group. Corresponding fretting currents and work of fretting measurements of high-compliance pins confirmed that minimal fretting was experienced at the interface, with elastic bending of the pin accounting for almost all applied displacement. Debris generated during testing were composed of titanium and chromium oxides, small amounts of cobalt and molybdenum oxides, and sodium and phosphate originating from the surrounding test solution. Post-test analyses of sample surfaces revealed substantially more surface damage on CoCrMo disks than Ti-6Al-4V pins, thought to be a result of adhesive wear of mixed oxide debris on the pin and abrasion of the disk by the oxide debris layer. Surface damage to high-compliance pins suggests some abrasion is unavoidable with geometric modifications.
Collapse
Affiliation(s)
- Stephanie M Smith
- Clemson-MUSC Bioengineering Program, Department of Bioengineering, Clemson University and the Medical University of South Carolina, Charleston, South Carolina, USA
| | - Jeremy L Gilbert
- Clemson-MUSC Bioengineering Program, Department of Bioengineering, Clemson University and the Medical University of South Carolina, Charleston, South Carolina, USA
| |
Collapse
|
27
|
Wendler T, Prietzel T, Möbius R, Fischer JP, Roth A, Zajonz D. Quantification of assembly forces during creation of head-neck taper junction considering soft tissue bearing: a biomechanical study. ARTHROPLASTY 2021; 3:20. [PMID: 35236493 PMCID: PMC8796494 DOI: 10.1186/s42836-021-00075-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Accepted: 02/28/2021] [Indexed: 11/16/2022] Open
Abstract
Background All current total hip arthroplasty (THA) systems are modular in design. Only during the operation femoral head and stem get connected by a Morse taper junction. The junction is realized by hammer blows from the surgeon. Decisive for the junction strength is the maximum force acting once in the direction of the neck axis, which is mainly influenced by the applied impulse and surrounding soft tissues. This leads to large differences in assembly forces between the surgeries. This study aimed to quantify the assembly forces of different surgeons under influence of surrounding soft tissue. Methods First, a measuring system, consisting of a prosthesis and a hammer, was developed. Both components are equipped with a piezoelectric force sensor. Initially, in situ experiments on human cadavers were carried out using this system in order to determine the actual assembly forces and to characterize the influence of human soft tissues. Afterwards, an in vitro model in the form of an artificial femur (Sawbones Europe AB, Malmo, Sweden) with implanted measuring stem embedded in gelatine was developed. The gelatine mixture was chosen in such a way that assembly forces applied to the model corresponded to those in situ. A study involving 31 surgeons was carried out on the aforementioned in vitro model, in which the assembly forces were determined. Results A model was developed, with the influence of human soft tissues being taken into account. The assembly forces measured on the in vitro model were, on average, 2037.2 N ± 724.9 N, ranging from 822.5 N to 3835.2 N. The comparison among the surgeons showed no significant differences in sex (P = 0.09), work experience (P = 0.71) and number of THAs performed per year (P = 0.69). Conclusions All measured assembly forces were below 4 kN, which is recommended in the literature. This could lead to increased corrosion following fretting in the head-neck interface. In addition, there was a very wide range of assembly forces among the surgeons, although other influencing factors such as different implant sizes or materials were not taken into account. To ensure optimal assembly force, the impaction should be standardized, e.g., by using an appropriate surgical instrument.
Collapse
Affiliation(s)
- Toni Wendler
- ZESBO - Centre for Research on Musculoskeletal Systems, Leipzig University, Semmelweisstraße 14, 04103, Leipzig, Germany. .,Institute of Anatomy, Leipzig University, Leipzig, Germany.
| | - Torsten Prietzel
- Department of Orthopaedics, Trauma and Reconstructive Surgery, Zeisigwaldkliniken Bethanien, Chemnitz, Germany
| | - Robert Möbius
- ZESBO - Centre for Research on Musculoskeletal Systems, Leipzig University, Semmelweisstraße 14, 04103, Leipzig, Germany.,Department of Neurosurgery, Leipzig University, Leipzig, Germany
| | - Jean-Pierre Fischer
- ZESBO - Centre for Research on Musculoskeletal Systems, Leipzig University, Semmelweisstraße 14, 04103, Leipzig, Germany.,Department of Orthopaedic, Trauma and Plastic Surgery, Leipzig University, Leipzig, Germany
| | - Andreas Roth
- Department of Orthopaedic, Trauma and Plastic Surgery, Leipzig University, Leipzig, Germany
| | - Dirk Zajonz
- ZESBO - Centre for Research on Musculoskeletal Systems, Leipzig University, Semmelweisstraße 14, 04103, Leipzig, Germany.,Department of Orthopaedics, Trauma and Reconstructive Surgery, Zeisigwaldkliniken Bethanien, Chemnitz, Germany.,Department of Orthopaedic, Trauma and Plastic Surgery, Leipzig University, Leipzig, Germany
| |
Collapse
|
28
|
Stockhausen KE, Riedel C, Belinski AV, Rothe D, Gehrke T, Klebig F, Gebauer M, Amling M, Citak M, Busse B. Variability in stem taper surface topography affects the degree of corrosion and fretting in total hip arthroplasty. Sci Rep 2021; 11:9348. [PMID: 33931680 PMCID: PMC8087796 DOI: 10.1038/s41598-021-88234-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Accepted: 03/19/2021] [Indexed: 12/29/2022] Open
Abstract
Degradation at the modular head-neck interface in total hip arthroplasty (THA) is predominately expressed in the form of corrosion and fretting, potentially causing peri-prosthetic failure by adverse reactions to metal debris. This retrieval study aimed to quantify variations in stem taper surface topographies and to assess the influence on the formation of corrosion and/or fretting in titanium alloy stem tapers combined with metal and ceramic heads. Four hip stem designs (Alloclassic, CLS, Bicontact and SL-Plus) were characterized using high-resolution 3D microscopy, and corrosion and fretting were rated using the Goldberg scoring scheme. Quantification of the taper surface topographies revealed a high variability in surface characteristics between threaded stem tapers: Alloclassic and CLS tapers feature deeply threaded trapezoid-shaped profiles with thread heights over 65 µm. The sawtooth-shaped Bicontact and triangular SL-Plus taper are characterized by low thread heights below 14 µm. Significantly lower corrosion and fretting scores were observed in lightly threaded compared to deeply threaded tapers in ceramic head combinations. No significant differences in corrosion or fretting scores with thread height were found in pairings with metal heads. Understanding the relationship between stem taper surface topography and the formation of corrosion and fretting could help to improve the performance of modern THAs and lead to longer-lasting clinical results.
Collapse
Affiliation(s)
- Kilian Elia Stockhausen
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestr. 55a, 22529, Hamburg, Germany
| | - Christoph Riedel
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestr. 55a, 22529, Hamburg, Germany
| | - Alex Victoria Belinski
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestr. 55a, 22529, Hamburg, Germany.,Department of Mechanical Engineering, University of California, 6141 Etcheverry Hall, Berkeley, CA, USA
| | - Dorothea Rothe
- Department of Orthopedic Surgery, Helios ENDO-Klinik, Holstenstraße 2, 22767, Hamburg, Germany
| | - Thorsten Gehrke
- Department of Orthopedic Surgery, Helios ENDO-Klinik, Holstenstraße 2, 22767, Hamburg, Germany
| | - Felix Klebig
- Department of Orthopedic Surgery, Helios ENDO-Klinik, Holstenstraße 2, 22767, Hamburg, Germany
| | - Matthias Gebauer
- Department of Orthopedic Surgery, Helios ENDO-Klinik, Holstenstraße 2, 22767, Hamburg, Germany
| | - Michael Amling
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestr. 55a, 22529, Hamburg, Germany
| | - Mustafa Citak
- Department of Orthopedic Surgery, Helios ENDO-Klinik, Holstenstraße 2, 22767, Hamburg, Germany
| | - Björn Busse
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestr. 55a, 22529, Hamburg, Germany. .,Interdisciplinary Competence Center for Interface Research (ICCIR), Martinistr. 52, 20251, Hamburg, Germany. .,Forum Medical Technology Health Hamburg (FMTHH), Butenfeld 34, 22529, Hamburg, Germany.
| |
Collapse
|
29
|
Feyzi M, Fallahnezhad K, Taylor M, Hashemi R. The mechanics of head-neck taper junctions: What do we know from finite element analysis? J Mech Behav Biomed Mater 2021; 116:104338. [PMID: 33524892 DOI: 10.1016/j.jmbbm.2021.104338] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Revised: 12/16/2020] [Accepted: 01/15/2021] [Indexed: 12/18/2022]
Abstract
Modular hip implants are widely used in hip arthroplasty because of the advantages they can offer such as flexibility in material combinations and geometrical adjustments. The mechanical environment of the modular junction in the body is quite challenging due to the complex and varying off-axial mechanical loads of physical activities applied to a tapered interface of two contacting materials (head and neck) assembled by an impact force intraoperatively. Experimental analogies to the in-vivo condition of the taper junction are complex, expensive and time-consuming to implement; hence, computational simulations have been a preferred approach taken by researchers for studying the mechanics of these modular junctions that can help us understand their failure mechanisms and improve their design and longevity after implantation. This paper provides a clearer insight into the mechanics of the head-neck taper junction through a careful review on the finite element studies of the junction and their findings. The effects of various factors on the mechanical outputs namely: stresses, micromotions, and contact situations are reviewed and discussed. Also, the simulation methodology of the studies in the literature is compared. Research opportunities for future are scrutinised through tabulating data and information that have been carefully retrieved form the reported findings.
Collapse
Affiliation(s)
- Mohsen Feyzi
- College of Science and Engineering, Medical Device Research Institute, Flinders University, Tonsley, SA, 5042, Australia
| | - Khosro Fallahnezhad
- College of Science and Engineering, Medical Device Research Institute, Flinders University, Tonsley, SA, 5042, Australia
| | - Mark Taylor
- College of Science and Engineering, Medical Device Research Institute, Flinders University, Tonsley, SA, 5042, Australia
| | - Reza Hashemi
- College of Science and Engineering, Medical Device Research Institute, Flinders University, Tonsley, SA, 5042, Australia.
| |
Collapse
|
30
|
Mueller U, Bormann T, Schroeder S, Kretzer JP. Taper junctions in modular hip joint replacements: What affects their stability? J Mech Behav Biomed Mater 2021; 116:104258. [PMID: 33497961 DOI: 10.1016/j.jmbbm.2020.104258] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Revised: 11/09/2020] [Accepted: 12/08/2020] [Indexed: 11/29/2022]
Abstract
BACKGROUND Although taper junctions are beneficial in the reconstruction of hip joints, some clinical concerns like the formation of adverse local tissue reactions have recently emerged. These reactions are associated with wear and corrosion products from the interface of insufficient taper connections regarding strength. Commonly used tapers vary in their geometric and topographical design parameter. Therefore, this study aims to evaluate interactions between design and surgical related parameters to the taper connection strength. METHODS In this study, the effect of the taper contact situation, surface roughness and head material in combination with assembly force on the taper connection strength were assessed using torque-off tests. Furthermore, the type of use in terms of single-use or re-use of the stem taper was investigated. RESULTS The study showed that the impaction force is the predominant factor that determines the taper strength followed by the type of use and the head material. The contact situation seems to slightly influence the determined torque-off moment, whereas the surface topography of the stem taper obviously plays a minor role for the taper connection strength. CONCLUSION Clinical users should be aware that an increased assembly force will strengthen the stability of the taper junction, whereas care should be taken when reusing hip stems with metal heads as this may decrease their connection strength.
Collapse
Affiliation(s)
- Ulrike Mueller
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany.
| | - Therese Bormann
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany.
| | - Stefan Schroeder
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany.
| | - J Philippe Kretzer
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany.
| |
Collapse
|
31
|
Büchner M, Cook RB, Dommann-Scherrer C, Meier C, Dommann A, Wahl P. It's worth cleaning - The examination of the female taper could identify a particular cause of trunnionosis at revision 16 years after total hip arthroplasty. J Mech Behav Biomed Mater 2021; 115:104304. [PMID: 33445103 DOI: 10.1016/j.jmbbm.2020.104304] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2020] [Revised: 11/28/2020] [Accepted: 12/29/2020] [Indexed: 11/18/2022]
Abstract
Adverse reaction to metal debris (ARMD) is an issue in metal-on-metal (MoM) total hip replacements (THR). It mainly affects large-head MoM THR, whereas 28-32 mm MoM pairings are associated with low long-term revision rates. However, the bearing surface is not necessarily the only cause of metal debris. This report documents with advanced analysis of the retrievals a particular cause of trunnionosis in late failure of a small diameter MoM THR and illustrates the importance of cleaning of the taper when seating the head in THR. A 65-year-old patient was revised due to ARMD 16 years after small diameter MoM THR. Debridement and exchange of the inlay and the head had been performed through an anterior approach. While the cup and the outer surface of the head were accessible to direct analysis by an optical coordinate measuring machine, the female taper had to be analysed indirectly by measuring an imprint. Wear from the cup and the head was within expected low ranges. The analysis of the female taper identified bone fragments, which contributed to trunnionosis. Failure due to ARMD after MoM THR is not necessarily caused by the bearing, but can be due to trunnionosis. Bone fragments within the taper contact in this case highlight the importance of meticulous cleaning of the taper before seating the head, to avoid trunnionosis.
Collapse
Affiliation(s)
- Mara Büchner
- Division of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, Winterthur, Switzerland
| | - Richard B Cook
- National Centre for Advanced Tribology at Southampton, University of Southampton, Southampton, United Kingdom
| | | | - Christoph Meier
- Division of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, Winterthur, Switzerland
| | - Alex Dommann
- EMPA Swiss Federal Laboratories for Material Science and Technology, St. Gallen, Switzerland; ARTORG Centre for Biomedical Engineering Research, University of Berne, Berne, Switzerland
| | - Peter Wahl
- Division of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, Winterthur, Switzerland.
| |
Collapse
|
32
|
Kawalkar AC, Vertzyas N, Neil MJ. Protection of the Femoral Trunnion During Acetabular Revision Hip Surgery-A Novel Technique. Arthroplast Today 2020; 6:911-913. [PMID: 33204787 PMCID: PMC7649106 DOI: 10.1016/j.artd.2020.09.015] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Revised: 09/22/2020] [Accepted: 09/27/2020] [Indexed: 11/16/2022] Open
Abstract
Revision of a failed acetabular component in the presence of an intact femoral prosthesis comprises approximately 20% of revision total hip replacements performed by the senior author. During this procedure, the femoral trunnion is at risk of damage because of scratching from retractors, reamers, or other instruments. Scratching can result in mechanically assisted crevice corrosion or adverse local-tissue reaction or trunnionosis leading to implant failure. We have used a variety of techniques for protection of the femoral taper over the last 30 years. We describe our current method of taper protection, using a cut segment of #5 silicon laryngeal airway, which is a simple and effective method.
Collapse
Affiliation(s)
- Abhijit C Kawalkar
- Orthopaedic and Joint Replacement Surgeon, Orange City Hospital and Research Institute, Nagpur, India
| | - Nick Vertzyas
- Orthopaedic Surgeon, & Chairman, Department of Orthopaedics, St Vincent's Clinic and Private Hospital, Sydney, New South Wales, Australia
| | - Michael J Neil
- Conjoint Associate Professor UNSW, Adjunct Associate Professor U Notre Dame, Orthopaedic Surgeon and Director, St. Vincent's Bone and Joint, St Vincent's Clinic and Private Hospital, Sydney, New South Wales, Australia
| |
Collapse
|
33
|
Morlock MM, Hube R, Wassilew G, Prange F, Huber G, Perka C. Taper corrosion: a complication of total hip arthroplasty. EFORT Open Rev 2020; 5:776-784. [PMID: 33312704 PMCID: PMC7722945 DOI: 10.1302/2058-5241.5.200013] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
The focus on taper corrosion in modular hip arthroplasty increased around 2007 as a result of clinical problems with large-head metal-on-metal (MoM) bearings on standard stems. Corrosion problems with bi-modular primary hip stems focused attention on this issue even more. Factors increasing the risk of taper corrosion were identified in laboratory and retrieval studies: stiffness of the stem neck, taper diameter and design, head diameter, offset, assembly force, head and stem material and loading. The high variability of the occurrence of corrosion in the clinical application highlights its multi-factorial nature, identifying the implantation procedure and patient-related factors as important additional factors for taper corrosion. Discontinuing the use of MoM has reduced the revisions due to metal-related pathologies dramatically from 49.7% (MoM > 32 mm), over 9.2% (MoM ⩽ 32 mm) to 0.8% (excluding all MoM). Further reduction can be achieved by omitting less stiff Ti-alloys and large metal heads (36 mm and above) against polyethylene (PE). Standardized taper assembly of smaller and ceramic heads will reduce the clinical occurrence of taper corrosion even further. If 36 mm heads are clinically indicated, only ceramic heads should be used. Taper-related problems will not comprise a major clinical problem anymore if the mentioned factors are respected.
Cite this article: EFORT Open Rev 2020;5:776-784. DOI: 10.1302/2058-5241.5.200013
Collapse
Affiliation(s)
| | | | - Georgi Wassilew
- Department for Orthopaedics and Orthopaedic Surgery, University of Greifswald, Greifswald, Germany
| | - Felix Prange
- TUHH Hamburg University of Technology, Hamburg, Germany
| | - Gerd Huber
- TUHH Hamburg University of Technology, Hamburg, Germany
| | - Carsten Perka
- Center for Musculoskeletal Surgery, Orthopedic Department, Charité - Universitätsmedizin Berlin, Berlin, Germany
| |
Collapse
|
34
|
Gustafson JA, Pourzal R, Levine BR, Jacobs JJ, Lundberg HJ. Modelling changes in modular taper micromechanics due to surgeon assembly technique in total hip arthroplasty. Bone Joint J 2020; 102-B:33-40. [PMID: 32600210 DOI: 10.1302/0301-620x.102b7.bjj-2019-1678.r1] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS The aim of this study was to develop a novel computational model for estimating head/stem taper mechanics during different simulated assembly conditions. METHODS Finite element models of generic cobalt-chromium (CoCr) heads on a titanium stem taper were developed and driven using dynamic assembly loads collected from clinicians. To verify contact mechanics at the taper interface, comparisons of deformed microgroove characteristics (height and width of microgrooves) were made between model estimates with those measured from five retrieved implants. Additionally, these models were used to assess the role of assembly technique-one-hit versus three-hits-on the taper interlock mechanical behaviour. RESULTS The model compared well to deformed microgrooves from the retrieved implants, predicting changes in microgroove height (mean 1.1 μm (0.2 to 1.3)) and width (mean 7.5 μm (1.0 to 18.5)) within the range of measured changes in height (mean 1.4 μm (0.4 to 2.3); p = 0.109) and width (mean 12.0 μm (1.5 to 25.4); p = 0.470). Consistent with benchtop studies, our model found that increasing assembly load magnitude led to increased taper engagement, contact pressure, and permanent deformation of the stem taper microgrooves. Interestingly, our model found assemblies using three hits at low loads (4 kN) led to decreased taper engagement, contact pressures and microgroove deformations throughout the stem taper compared with tapers assembled with one hit at the same magnitude. CONCLUSION These findings suggest additional assembly hits at low loads lead to inferior taper interlock strength compared with one firm hit, which may be influenced by loading rate or material strain hardening. These unique models can estimate microgroove deformations representative of real contact mechanics seen on retrievals, which will enable us to better understand how both surgeon assembly techniques and implant design affect taper interlock strength. Cite this article: Bone Joint J 2020;102-B(7 Supple B):33-40.
Collapse
Affiliation(s)
- Jonathan A Gustafson
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, USA
| | - Robin Pourzal
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, USA
| | - Brett R Levine
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, USA
| | - Joshua J Jacobs
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, USA
| | - Hannah J Lundberg
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, USA
| |
Collapse
|
35
|
Baumann AP, Vesnovsky O, Topoleski LDT, Donaldson FE, McMinn NLL, Vignola A, Di Prima M. Specimen-Specific Finite Element Models for Predicting Fretting Wear in Total Hip Arthroplasty Tapers. J Biomech Eng 2020; 142:071002. [PMID: 31913446 DOI: 10.1115/1.4045904] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2019] [Indexed: 11/08/2022]
Abstract
Products from fretting wear and corrosion in the taper junction of total hip arthroplasty (THA) devices can lead to adverse local tissue reactions. Predicting damage as a function of design parameters would aid in the development of more robust devices. The objectives of this study were to develop an automated method for identifying areas of fretting wear on THA taper junctions, and to assess the predictive ability of a finite element model to simulate fretting wear in THA taper junctions. THA constructs were fatigue loaded, thus inducing damage on the stem taper. An automated imaging and analysis algorithm quantified fretting wear on the taper surfaces. Specimen-specific finite element models were used to calculate fretting work done (FWD) at the taper junction. Simulated FWD was correlated to imaged fretting wear. Results showed that the automated imaging approach identified fretting wear on the taper surface. Additionally, finite element models showed the greatest predictive ability for tapers exhibiting distal contact. Finite element models predicted an average of 30.3% of imaged fretting wear. With additional validation, the imaging and finite element techniques may be useful to manufacturers and regulators in the development and review of new THA devices.
Collapse
Affiliation(s)
- Andrew P Baumann
- U.S. Food and Drug Administration, Center for Devices and Radiological Health, Office of Science and Engineering Laboratories, 10903 New Hampshire Avenue, Building 62, Room 2110, Silver Spring, MD 20993
| | - Oleg Vesnovsky
- U.S. Food and Drug Administration, Center for Devices and Radiological Health, Office of Science and Engineering Laboratories, 10903 New Hampshire Avenue, Building 62, Room 2227, Silver Spring, MD 20993
| | - L D Timmie Topoleski
- Department of Mechanical Engineering, University of Maryland, Baltimore County, 1000 Hilltop Circle, Baltimore, MD 21250
| | - Finn E Donaldson
- U.S. Food and Drug Administration, Center for Devices and Radiological Health, Office of Product Evaluation and Quality, OHT2: Office of Cardiovascular Devices, 10903 New Hampshire Avenue, Building 66, Room 1253, Silver Spring, MD 20993
| | - Nicole L L McMinn
- U.S. Food and Drug Administration, Center for Devices and Radiological Health, Office of Product Evaluation and Quality, OHT6: Office of Orthopedic Devices, 10903 New Hampshire Avenue, Building 66, Room 4435, Silver Spring, MD 20993
| | - Amelia Vignola
- U.S. Food and Drug Administration, Center for Devices and Radiological Health, Office of Science and Engineering Laboratories, 10903 New Hampshire Avenue, Building 62, Silver Spring, MD 20993
| | - Matthew Di Prima
- U.S. Food and Drug Administration, Center for Devices and Radiological Health, Office of Science and Engineering Laboratories, 10903 New Hampshire Avenue, Building 62, Room 2124, Silver Spring, MD 20993
| |
Collapse
|
36
|
Chaudhary M, Boruah S, Muratoglu OK, Varadarajan KM. Evaluation of pull-off strength and seating displacement of sleeved ceramic revision heads in modular hip arthroplasty. J Orthop Res 2020; 38:1523-1528. [PMID: 31769536 DOI: 10.1002/jor.24536] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/02/2019] [Accepted: 11/12/2019] [Indexed: 02/04/2023]
Abstract
Corrosion in revision total hip arthroplasty can be mitigated using a ceramic head on a well-fixed in situ stem, but concerns of their early failure because of any surface defects on in situ stem necessitates the use of a titanium sleeve, which furnishes a factory-finish surface. These sleeves are manufactured in different sizes allowing neck-length adjustment. The strength of the taper junction of non-sleeved primary heads is well-investigated, but the influence of an interposed titanium sleeve on achieving a secure taper lock is unclear. Therefore, this study aimed to investigate the pull-off strength and seating displacement of revision ceramic heads and titanium taper sleeves. Two different head diameters and two different taper adapter sleeve offset lengths were mated with trunnions at two different impaction forces. The seating displacement and pull-off force was recorded for each specimen. Profilometry of the grooved outer surfaces of the sleeve and trunnion was done before and after testing to analyze the change in surface roughness. The influence of head diameter, sleeve offset, and impaction force on seating displacement and pull-off force was analyzed using analysis of covariance. Pull-off forces for 6 kN assembly force were approximately three times those for 2 kN. The head diameter did not have a significant effect on the measured parameters. Compared with short offset length sleeves, extra-long increased seating displacement by 31% and reduced pull-off forces by 15%. While sleeves of different offset lengths permit control of neck length, surgeons must be careful of the impact of this choice on the stability of implant. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 38:1523-1528, 2020.
Collapse
Affiliation(s)
- Miriam Chaudhary
- Technology Implementation Research Center, Massachusetts General Hospital, 55 Fruit Street, Boston, Massachusetts, 02114
| | - Sourabh Boruah
- Technology Implementation Research Center, Massachusetts General Hospital, 55 Fruit Street, Boston, Massachusetts, 02114
| | - Orhun K Muratoglu
- Harris Orthopaedics Laboratory, Massachusetts General Hospital, Boston, Massachusetts
| | - Kartik M Varadarajan
- Technology Implementation Research Center, Massachusetts General Hospital, 55 Fruit Street, Boston, Massachusetts, 02114
| |
Collapse
|
37
|
Hall DJ, Pourzal R, Jacobs JJ. What Surgeons Need to Know About Adverse Local Tissue Reaction in Total Hip Arthroplasty. J Arthroplasty 2020; 35:S55-S59. [PMID: 32005621 PMCID: PMC7239747 DOI: 10.1016/j.arth.2020.01.016] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Accepted: 01/07/2020] [Indexed: 02/01/2023] Open
Abstract
Adverse local tissue reactions (ALTRs) were first associated with patients with failed metal-on-metal surface replacements and total hip arthroplasty (THA). However, an increasing number of cases of ALTR in metal-on-polyethylene (MOP) THA patients is being reported. Clinically, ALTR appears as benign, aseptic masses or bursae in the periprosthetic tissues. Histopathologically, ALTRs are distinguished by an intense lymphocyte infiltrate, destruction of the synovial surfaces, widespread necrosis, and fibrin exudate. Tribocorrosion of modular junctions appears to be the cause of ALTR in MOP patients. The various tribocorrosion damage modes occurring at modular junctions produce metal ions and a diversity of particulates in relation to size, chemical composition, and structure. The mechanisms by which these various products of tribocorrosion lead to ALTR are still a matter of considerable research. This review clarifies what constitutes ALTR, its relationship to implant factors, and highlights current methods for diagnosis and management of patients with ALTR in the setting of MOP THA.
Collapse
Affiliation(s)
- Deborah J Hall
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| | - Robin Pourzal
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| | - Joshua J Jacobs
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| |
Collapse
|
38
|
Influence of Different Damage Patterns of the Stem Taper on Fixation and Fracture Strength of Ceramic Ball Heads for Total Hip Replacement. BIOMED RESEARCH INTERNATIONAL 2020; 2020:7542062. [PMID: 32509869 PMCID: PMC7244970 DOI: 10.1155/2020/7542062] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/14/2020] [Revised: 04/01/2020] [Accepted: 04/15/2020] [Indexed: 11/17/2022]
Abstract
Background Modularity finds frequent application in total hip replacement, allowing a preferable individual configuration and a simplified revision by retaining the femoral stem and replacing the prosthetic head. However, micromotions within the interface between the head and the stem taper can arise, resulting in the release of wear debris and corrosion products. The aim of our experimental study was to evaluate the influence of different taper damages on the fixation and fracture stability of ceramic femoral heads, after static and dynamic implant loading. Methods Ceramic ball heads (36 mm diameter) and 12/14 stem tapers made of titanium with various mild damage patterns (intact, scratched, and truncated) were tested. The heads were assembled on the taper with a quasistatic load of 2 kN and separated into a static and a dynamic group afterwards. The dynamic group (n = 18) was loaded over 1.5 million gait cycles in a hip wear simulator (ISO 14242-1). In contrast, the static group (n = 18) was not mechanically loaded after assembly. To determine the taper stability, all heads of the dynamic and static groups were either pulled off (ASTM 2009) or turned off (ISO 7206-16). A head fracture test (ISO 7206-10) was also performed. Subsequent to the fixation stability tests, the taper surface was visually evaluated in terms of any signs of wear or corrosion after the dynamic loading. Results In 10 of the 18 cases, discoloration of the taper was determined after the dynamic loading and subsequent cleaning, indicating the first signs of corrosion. Pull-off forces as well as turn-off moments were increased between 23% and 54% after the dynamic loading compared to the unloaded tapers. No significant influence of taper damage was determined in terms of taper fixation strength. However, the taper damage led to a decrease in fracture strength by approximately 20% (scratched) and 40% (truncated), respectively. Conclusion The results suggest that careful handling and accurate manufacturing of the stem taper are crucial for the ceramic head fracture strength, even though a mild damage showed no significant influence on taper stability. Moreover, our data indicate that a further seating of the prosthetic head may occur during daily activities, when the resulting hip force increases the assembly load.
Collapse
|
39
|
Bormann T, Mai PT, Gibmeier J, Sonntag R, Müller U, Kretzer JP. Corrosion Behavior of Surface-Treated Metallic Implant Materials. MATERIALS 2020; 13:ma13092011. [PMID: 32344822 PMCID: PMC7254368 DOI: 10.3390/ma13092011] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 04/22/2020] [Accepted: 04/23/2020] [Indexed: 11/16/2022]
Abstract
Corrosion of taper connections in total hip arthroplasty remains of concern, as particles and ions generated by corrosive processes can cause clinical problems such as periprosthetic osteolysis or adverse reaction to metallic debris. Mechanical surface treatments that introduce compressive residual stresses (RSs) in metallic materials can lead to a better performance in terms of fretting and fatigue and may lower the susceptibility to corrosion. The study investigates the impact of mechanical surface treatments on the corrosion behavior of metallic biomaterials. Compressive RSs were introduced by deep rolling and microblasting in Ti6Al4V and CoCrMo samples. Polished samples served as reference. Corrosion behavior was characterized by repeated anodic polarization. Residual stresses of up to about −900 MPa were introduced by deep rolling with a reach in depth of approximately 500 µm. Microblasting led to compressive RSs up to approximately −800 and −600 MPa for Ti6Al4V and CoCrMo, respectively, in the immediate vicinity of the surface. For Ti6Al4V, microblasting resulted in decreased corrosion resistance with lower breakdown potentials and/or increased passive current densities in comparison to the polished and deep-rolled samples. The corrosion behavior of CoCrMo on the other hand was not affected by the mechanical surface treatments.
Collapse
Affiliation(s)
- Therese Bormann
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, 69118 Heidelberg, Germany
- Correspondence:
| | - Phuong Thao Mai
- Institute for Applied Materials, Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany
| | - Jens Gibmeier
- Institute for Applied Materials, Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany
| | - Robert Sonntag
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, 69118 Heidelberg, Germany
| | - Ulrike Müller
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, 69118 Heidelberg, Germany
| | - J. Philippe Kretzer
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, 69118 Heidelberg, Germany
| |
Collapse
|
40
|
Rieker CB, Wahl P. What the Surgeon Can Do to Reduce the Risk of Trunnionosis in Hip Arthroplasty: Recommendations from the Literature. MATERIALS 2020; 13:ma13081950. [PMID: 32326259 PMCID: PMC7215371 DOI: 10.3390/ma13081950] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/29/2020] [Revised: 04/15/2020] [Accepted: 04/17/2020] [Indexed: 01/24/2023]
Abstract
Trunnionosis, defined as wear and corrosion at the head–neck taper connection, is a cause of failure in hip arthroplasty. Trunnionosis is linked to a synergistic combination of factors related to the prosthesis, the patient, and the surgeon. This review presents analytical models that allow for the quantification of the impact of these factors, with the aim of providing practical recommendations to help surgeons minimize the occurrence of this failure mode. A tighter fit reduces micromotion and, consequently, fretting of the taper connection. The paramount parameters controlling the fixation force are the coefficient of friction and the impaction force. The influence of the head diameter, as well as of the diameter and angle of the taper, is comparatively small, but varus alignment of the taper and heads with longer necks are unfavourable under physiologic loads. The trunnion should be rinsed, cleaned, and dried carefully, while avoiding any contamination of the bore—the female counterpart within the head—prior to assembly. Biological debris, and even residual water, might critically reduce the fixation of the taper connection between the head and the neck. The impaction force applied to the components should correspond to at least two strong blows with a 500 g hammer, striking the head with an ad hoc impactor aligned with the axis of the taper. These strong blows should correspond to a minimum impaction force of 4000 N.
Collapse
Affiliation(s)
- Claude B. Rieker
- Scientific Affairs, Zimmer Biomet EMEA (Europa, Middle East and Africa), Sulzerallee 8, 8404 Winterthur, Switzerland
- Correspondence:
| | - Peter Wahl
- Division of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, Brauerstrasse 15, 8400 Winterthur, Switzerland;
| |
Collapse
|
41
|
Taper Design, Head Material, and Manufacturer Affect the Onset of Fretting Under Simulated Corrosion Conditions. J Arthroplasty 2020; 35:1117-1122. [PMID: 31836326 DOI: 10.1016/j.arth.2019.11.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2019] [Revised: 10/30/2019] [Accepted: 11/05/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND We investigated the effect of taper design, head material, and manufacturer on simulated mechanically assisted crevice corrosion (MACC). METHODS Six pristine C-taper stems coupled with alumina-zirconia or cobalt-chromium (CoCr) heads were tested in a mechanical/electrochemical setup to measure average fretting currents and fretting current onset loads. Outcomes were compared with previous data from V40 tapers from the same manufacturer and 12/14 tapers from another manufacturer. RESULTS Within a single manufacturer, differences in average fretting current between V40 and C-taper designs were dependent on head material. Only with V40 tapers did CoCr heads show higher average fretting currents than ceramic heads. Between manufacturers, differences were found between similar taper designs, as 12/14 taper couples showed higher average fretting currents than C-taper couples, regardless of head material. CONCLUSION Taper design, head material, and factors inherent to different manufacturers influence fretting current in simulated MACC. Unlike clinical and retrieval studies, this experimental design allows for investigations of factors affecting MACC in a controlled environment. Taper design, independent of manufacturer, contributes to the observed differences in average fretting current between head materials. In some taper designs, head composition, specifically ceramic, should not be considered alone to reduce risk of corrosion.
Collapse
|
42
|
Bechstedt M, Gustafson JA, Mell SP, Gührs J, Morlock MM, Levine BR, Lundberg HJ. Contact conditions for total hip head-neck modular taper junctions with microgrooved stem tapers. J Biomech 2020; 103:109689. [PMID: 32139099 DOI: 10.1016/j.jbiomech.2020.109689] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2019] [Revised: 02/21/2020] [Accepted: 02/23/2020] [Indexed: 10/24/2022]
Abstract
Implant failure due to fretting-corrosion of head-neck modular junctions is a rising problem in total hip arthroplasty. Fretting-corrosion initiates when micromotion leads to metal release; however, factors leading to micromotion, such as microgrooves on the stem taper, are not fully understood. The purpose of this study is to describe a finite element analysis technique to determine head-neck contact mechanics and investigate the effect of stem taper microgroove height during head-neck assembly. Two-dimensional axisymmetric finite element models were created. Models were created for a ceramic femoral head and a CoCrMo femoral head against Ti6Al4V stem tapers and compared to available data from prior experiments. Stem taper microgroove height was investigated with a generic 12/14 model. Head-neck assembly was performed to four maximum loads (500 N, 2000 N, 4000 N, 8000 N). For the stem taper coupled with the ceramic head, the number of microgrooves in contact and plastically deformed differed by 2.5 microgrooves (4%) and 6.5 microgrooves (11%), respectively, between the finite element models and experiment. For the stem taper coupled with the CoCrMo head, all microgrooves were in contact after all assembly loads in the finite element model due to an almost identical conical angle between the taper surfaces. In the experiments, all grooves were only in contact for the 8000 N assembly load. Contact area, plastic (permanent) deformation, and contact pressure increased with increasing assembly loads and deeper microgrooves. The described modeling technique can be used to investigate the relationship between implant design factors, allowing for optimal microgroove design within material couples.
Collapse
Affiliation(s)
- Maren Bechstedt
- Institute of Biomechanics, TUHH Hamburg University of Technology, 21073 Hamburg, Germany
| | - Jonathan A Gustafson
- Department of Orthopedic Surgery, Rush University Medical Center, 1611 W Harrison St Suite 201, Chicago, IL 60612, United States
| | - Steven P Mell
- Department of Orthopedic Surgery, Rush University Medical Center, 1611 W Harrison St Suite 201, Chicago, IL 60612, United States
| | - Julian Gührs
- Institute of Biomechanics, TUHH Hamburg University of Technology, 21073 Hamburg, Germany
| | - Michael M Morlock
- Institute of Biomechanics, TUHH Hamburg University of Technology, 21073 Hamburg, Germany
| | - Brett R Levine
- Department of Orthopedic Surgery, Rush University Medical Center, 1611 W Harrison St Suite 201, Chicago, IL 60612, United States
| | - Hannah J Lundberg
- Department of Orthopedic Surgery, Rush University Medical Center, 1611 W Harrison St Suite 201, Chicago, IL 60612, United States.
| |
Collapse
|
43
|
Falkenberg A, Biller S, Morlock MM, Huber G. Micromotion at the head-stem taper junction of total hip prostheses is influenced by prosthesis design-, patient- and surgeon-related factors. J Biomech 2020; 98:109424. [DOI: 10.1016/j.jbiomech.2019.109424] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2019] [Revised: 09/25/2019] [Accepted: 10/13/2019] [Indexed: 12/28/2022]
|
44
|
Crackau M, Märtens N, Harnisch K, Berth A, Döring J, Lohmann CH, Halle T, Bertrand J. In vivo corrosion and damages in modular shoulder prostheses. J Biomed Mater Res B Appl Biomater 2019; 108:1764-1778. [PMID: 31763747 DOI: 10.1002/jbm.b.34519] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2019] [Revised: 09/30/2019] [Accepted: 11/04/2019] [Indexed: 11/08/2022]
Abstract
Wear and corrosion at taper junctions of orthopaedic endoprostheses remain of great concern and are associated with adverse clinical reactions. Whereas tribocorrosion of hip tapers was extensively investigated, there is only little knowledge regarding the clinical performance of modular total shoulder prostheses. This retrieval study evaluated 35 modular taper junctions of anatomical shoulder explants using stereomicroscopy, confocal microscopy, as well as optical and scanning electron microscopy to determine the damage modes as well as the effects of taper topography and alloy microstructure. Among all humeral head tapers, 89% exhibited material degradation. Different overlapping wear mechanisms were identified such as plastic deformation, adhesive material transfer, microploughing, and fretting damage. Only CoCrMo cast alloy heads showed a susceptibility to electrochemically dominated fretting in comparison to CoCrMo wrought alloy. Moreover, corundum blasted stem tapers show a significantly increased incidence rate for microploughing. To date, this is the most comprehensive study on the damage types of modular taper junctions of anatomical shoulder arthroplasty proving the existence of fretting even on less weight-bearing implants. This study revealed critical fretting factors, such as the surface finish and the alloy type that are essential for the development of countermeasures that avoid any taper corrosion.
Collapse
Affiliation(s)
- Maria Crackau
- Institute of Materials and Joining Technology, Otto-von-Guericke University, Magdeburg, Germany.,Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Nicole Märtens
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Karsten Harnisch
- Institute of Materials and Joining Technology, Otto-von-Guericke University, Magdeburg, Germany
| | - Alexander Berth
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Joachim Döring
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Thorsten Halle
- Institute of Materials and Joining Technology, Otto-von-Guericke University, Magdeburg, Germany
| | - Jessica Bertrand
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| |
Collapse
|
45
|
Valente G, Lanting B, MacDonald S, Teeter MG, Van Citters D, Howard J. Femoral head material loss at the head-neck junction in total hip arthroplasty: the effect of head size, stem material and stem offset. Hip Int 2019; 29:647-651. [PMID: 30499342 DOI: 10.1177/1120700018814473] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION Material loss at the head-neck junction in total hip arthroplasty may cause adverse clinical symptoms and implant failure. The purpose of this study was to quantitatively examine the effects of head size, stem material and stem offset on material loss of the head-neck taper interface of a single trunnion design in retrieval implants of metal on polyethylene bearing surfaces. METHODS A retrieval study was performed to identify all 28-mm and 32-mm femoral heads from a single implant/taper design implanted for >2 years. This included n = 56 of the 28-mm heads and n = 23 of the 32-mm heads. The 28-mm femoral heads were matched to 32-mm femoral heads based on time in vivo and head length. A coordinate measuring machine was used to determine maximum linear corrosion depth (MLD). Differences in MLD for head diameter, stem material, and stem offset were determined. RESULTS There were no differences between groups for age, gender, BMI, or implantation time. There was no difference in MLD between 28 mm and 32 mm matched paired head diameters (p = 0.59). There was also no difference in MLD between titanium or cobalt-chromium stems (p = 0.79), and regular or high-offset stems (p = 0.95). CONCLUSION There is no statistical difference in femoral head MLD at the head-neck junction in THA between 28-mm and 32-mm matched paired femoral heads, similar or mixed alloy coupled femoral head stem constructs, and regular or high offset stems.
Collapse
Affiliation(s)
- Giuseppe Valente
- Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine and Dentistry, Western University, London Health Sciences Centre, University Hospital, London, ON, Canada
| | - Brent Lanting
- Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine and Dentistry, Western University, London Health Sciences Centre, University Hospital, London, ON, Canada
| | - Steven MacDonald
- Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine and Dentistry, Western University, London Health Sciences Centre, University Hospital, London, ON, Canada
| | - Matthew G Teeter
- Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada.,Surgical Innovation Program, Lawson Health Research Institute, London, ON, Canada
| | | | - James Howard
- Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine and Dentistry, Western University, London Health Sciences Centre, University Hospital, London, ON, Canada
| |
Collapse
|
46
|
Bitter T, Khan I, Marriott T, Lovelady E, Verdonschot N, Janssen D. The effects of manufacturing tolerances and assembly force on the volumetric wear at the taper junction in modular total hip arthroplasty. Comput Methods Biomech Biomed Engin 2019; 22:1061-1072. [DOI: 10.1080/10255842.2019.1627524] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Affiliation(s)
- Thom Bitter
- Orthopaedic Research lab, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| | | | | | | | - Nico Verdonschot
- Orthopaedic Research lab, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
- Laboratory for Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, Enschede, The Netherlands
| | - Dennis Janssen
- Orthopaedic Research lab, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| |
Collapse
|
47
|
Snethen K, Hernandez J, Harman M. The effect of manufacturing tolerances on the mechanical environment of taper junctions in modular TKR. J Mech Behav Biomed Mater 2019; 97:49-57. [PMID: 31100485 DOI: 10.1016/j.jmbbm.2019.04.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2018] [Revised: 10/19/2018] [Accepted: 04/11/2019] [Indexed: 10/27/2022]
Abstract
Taper design is known to influence corrosive behavior in taper junctions used in modular orthopaedic devices. Manufacturing tolerance of bore-cone tapers is a critical design parameter due to the effect on taper fit, but the effect of variations in manufacturing tolerance on the mechanics of taper junctions has not been well characterized, particularly in modular total knee replacement (TKR). The purpose of this study was to investigate the effect of manufacturing tolerance on stress and micromotion of modular TKR taper junctions. A 3D finite element (FE) model of a modular TKR taper junction was developed and assigned elastoplastic material properties. Model taper geometry was varied by perturbing the angle mismatch by 0.05° between ±0.25° and represented expected variation in manufacturing tolerance. Stress and micromotion were calculated during dynamic FE simulations for each taper junction geometry under varying activity loads and material combinations. Although an increase in angle mismatch generally resulted in higher stress and micromotion, plastic material behavior disrupted this trend for larger angle mismatches. Model predictions corresponded with corrosion behavior evident in vitro. If the FE results obtained here apply in vivo, the absence of elastoplastic material properties in a taper model may grossly overestimate the micromotion and underestimate corrosion behavior and ion release. It is recommended that manufacturing tolerances of bore-cone tapers in modular TKR designs should produce angle mismatches within 0.1° at the taper junction.
Collapse
Affiliation(s)
- Kyle Snethen
- Bioengineering Department, Clemson University, Clemson, USA
| | | | - Melinda Harman
- Bioengineering Department, Clemson University, Clemson, USA.
| |
Collapse
|
48
|
The Influence of Assembly Force on the Material Loss at the Metallic Head-Neck Junction of Hip Implants Subjected to Cyclic Fretting Wear. METALS 2019. [DOI: 10.3390/met9040422] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The impaction force required to assemble the head and stem components of hip implants is proven to play a major role in the mechanics of the taper junction. However, it is not clear if the assembly force could have an effect on fretting wear, which normally occurs at the junction. In this study, an adaptive finite element model was developed for a CoCr/CoCr head-neck junction with an angular mismatch of 0.01° in order to simulate the fretting wear process and predict the material loss under various assembly forces and over a high number of gait cycles. The junction was assembled with 2, 3, 4, and 5 kN and then subjected to 1,025,000 cycles of normal walking gait loading. The findings showed that material removal due to fretting wear increased when raising the assembly force. High assembly forces induced greater contact pressures over larger contact regions at the interface, which, in turn, resulted in more material loss and wear damage to the surface when compared to lower assembly forces. Although a high assembly force (greater than 4 kN) can further improve the initial strength and stability of the taper junction, it appears that it also increases the degree of fretting wear. Further studies are needed to investigate the assembly force in the other taper designs, angular mismatches, and material combinations.
Collapse
|
49
|
Materials for Hip Prostheses: A Review of Wear and Loading Considerations. MATERIALS 2019; 12:ma12030495. [PMID: 30764574 PMCID: PMC6384837 DOI: 10.3390/ma12030495] [Citation(s) in RCA: 99] [Impact Index Per Article: 19.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/11/2019] [Revised: 01/31/2019] [Accepted: 01/31/2019] [Indexed: 12/15/2022]
Abstract
Replacement surgery of hip joint consists of the substitution of the joint with an implant able to recreate the articulation functionality. This article aims to review the current state of the art of the biomaterials used for hip implants. Hip implants can be realized with different combination of materials, such as metals, ceramics and polymers. In this review, we analyze, from international literature, the specific characteristics required for biomaterials used in hip joint arthroplasty, i.e., being biocompatible, resisting heavy stress, opposing low frictional forces to sliding and having a low wear rate. A commentary on the evolution and actual existing hip prostheses is proposed. We analyzed the scientific literature, collecting information on the material behavior and the human-body response to it. Particular attention has been given to the tribological behavior of the biomaterials, as friction and wear have been key aspects to improve as hip implants evolve. After more than 50 years of evolution, in term of designs and materials, the actual wear rate of the most common implants is low, allowing us to sensibly reduce the risk related to the widespread debris distribution in the human body.
Collapse
|
50
|
Falkenberg A, Drummen P, Morlock MM, Huber G. Determination of local micromotion at the stem-neck taper junction of a bi-modular total hip prosthesis design. Med Eng Phys 2019; 65:31-38. [PMID: 30679024 DOI: 10.1016/j.medengphy.2019.01.003] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2018] [Revised: 01/08/2019] [Accepted: 01/10/2019] [Indexed: 11/26/2022]
Abstract
High rates of clinical complications with bi-modular hip prostheses are attributed to failure of the stem-neck taper junction. Taper wear analyses have shown extensive material loss as a result of corrosion, potentially initiated by micromotion. The purpose of the study was to determine the amount of micromotion at this junction for different loading, assembly and material conditions. Micromotion between the neck adapter (CoCr29Mo6-alloy) and the stem (TiMo12Zr6Fe2-alloy; both Rejuvenate, Stryker) within the taper junction of a bi-modular hip stem were determined by image matching analysis of consecutively recorded images through windows in the stem component. A finite element model was used to determine the micromotion in the taper regions outside the windows and validated with the measured micromotion. With the model, the influence of the load amplitude, assembly force and component materials were then investigated. Determined micromotion (14-79 µm) by far exceeded critical values (5 µm) associated with the onset of fretting corrosion. Increasing assembly forces achieved a significant reduction in micromotion. The numerical model revealed insufficient assembly to cause the neck to perform rocking motions under load, repetitively changing taper contact in combination with gap opening, which facilitates fluid ingress into the junction. Changing the stem material to a stiffer Ti-alloy achieved a reduction of the micromotion of about 30%. This study emphasises the high importance of material selection, assembly force and loading on the susceptibility of bi-modular hip stems to fretting and crevice corrosion. These findings can serve to explain the increased rate of clinically reported problems with this particular prosthesis design.
Collapse
Affiliation(s)
- Adrian Falkenberg
- Institute of Biomechanics, Hamburg University of Technology (TUHH), Denickestrasse 15, Hamburg 21073, Germany.
| | - Paul Drummen
- Institute of Biomechanics, Hamburg University of Technology (TUHH), Denickestrasse 15, Hamburg 21073, Germany
| | - Michael M Morlock
- Institute of Biomechanics, Hamburg University of Technology (TUHH), Denickestrasse 15, Hamburg 21073, Germany
| | - Gerd Huber
- Institute of Biomechanics, Hamburg University of Technology (TUHH), Denickestrasse 15, Hamburg 21073, Germany
| |
Collapse
|