1
|
Stücker S, Koßlowski F, Buchholz A, Lohmann CH, Bertrand J. High frequency of BCP, but less CPP crystal-mediated calcification in cartilage and synovial membrane of osteoarthritis patients. Osteoarthritis Cartilage 2024:S1063-4584(24)01176-2. [PMID: 38735362 DOI: 10.1016/j.joca.2024.04.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Revised: 04/03/2024] [Accepted: 04/08/2024] [Indexed: 05/14/2024]
Abstract
OBJECTIVE Ectopic articular calcification is a common phenomenon of osteoarthritic joints, and closely related with disease progression. Identification of the involved calcium crystal types represents an important topic in research and clinical practice. Difficulties in accurate detection and crystal type identification have led to inconsistent data on the prevalence and spatial distribution of BCP and CPP deposition. METHOD Combining multiple imaging methods including conventional radiography, histology and Raman spectroscopy, this study provides a comprehensive analysis of BCP and CPP based calcification, its frequency and distribution in cartilage and synovial membrane samples of 92 OA patients undergoing knee replacement surgery. RESULTS Conventional radiography showed calcifications in 35% of patients. Von Kossa staining detected calcified deposits in 88% and 57% of cartilage and synovial samples, respectively. BCP crystals presented as brittle deposits on top of the cartilage surface or embedded in synovial tissue. CPP deposits appeared as larger granular needle-shaped clusters or dense circular pockets below the cartilage surface or within synovial tissue. Spectroscopic analysis detected BCP crystals in 75% of cartilage and 43% of synovial samples. CPP deposition was only detected in 18% of cartilage and 15% of synovial samples, often coinciding with BCP deposits. CONCLUSION BCP is the predominant crystal type in calcified cartilage and synovium while CPP deposition is rare, often coinciding with BCP. Distinct and qualitative information on BCP and CPP deposits in joint tissues give rise to the speculation that different disease entities are involved that might need different treatment strategies.
Collapse
Affiliation(s)
- Sina Stücker
- Department of Orthopaedic Surgery, Otto-von-Guericke-University, Magdeburg, Germany
| | - Franziska Koßlowski
- Department of Orthopaedic Surgery, Otto-von-Guericke-University, Magdeburg, Germany
| | - Adrian Buchholz
- Department of Orthopaedic Surgery, Otto-von-Guericke-University, Magdeburg, Germany
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke-University, Magdeburg, Germany
| | - Jessica Bertrand
- Department of Orthopaedic Surgery, Otto-von-Guericke-University, Magdeburg, Germany.
| |
Collapse
|
2
|
Osmanski-Zenk K, Klinder A, Pingsmann A, Lohmann CH, Bail HJ, Kladny B, Mittelmeier W. Institutional Surgical Setting and Volume Effects of Certified Arthroplasty Centers in Germany: Evaluation of the Quality of Care in a 5-Year Comparison. Healthcare (Basel) 2024; 12:904. [PMID: 38727461 PMCID: PMC11083652 DOI: 10.3390/healthcare12090904] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2024] [Revised: 04/15/2024] [Accepted: 04/26/2024] [Indexed: 05/13/2024] Open
Abstract
To improve arthroplasty care quality, the EndoCert initiative focuses on structural, processual, and surgeon-related quality assurance. The aim of this study was to assess the impact of a surgeon's case load in certified centers on quality of care, distinguished by different types of surgeons. Data from the annual reports of EndoCert certified centers for the years 2017 to 2021 were analyzed. The study revealed reduced numbers of cases, while the number of surgeons remained constant. Since 2020, the decrease in the average case load per surgeons has become more pronounced. There were also differences between senior (sECrs) and EndoCert-registered surgeons (ECrs). Before the 2020 pandemic, over half of surgeons exceeded minimum annual case requirements, while, afterwards, this number declined, especially for the ECrs. Affiliated surgeons, who are also sECrs or ECrs, performed predominantly lower numbers of arthroplasties. However, a higher percentage of affiliated surgeons in a center correlated with faster surgeries and lower mortality rates. High numbers of arthroplasties per center or surgeon were not necessarily associated with better quality indicators, especially in the knee. While the comprehensive quality standards may offset volume effects, EndoCert should reconsider minimum volume regulations based on surgeon, but also on each joint.
Collapse
Affiliation(s)
- Katrin Osmanski-Zenk
- Orthopedic Clinic and Policlinic, University Rostock Medical Center, 18057 Rostock, Germany
| | - Annett Klinder
- Orthopedic Clinic and Policlinic, University Rostock Medical Center, 18057 Rostock, Germany
| | - Andreas Pingsmann
- Professional Association for Orthopaedics and Trauma Surgery, Biberburg Orthopaedic Associates, 14089 Berlin, Germany
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke-University, 39120 Magdeburg, Germany
| | - Hermann Josef Bail
- Department of Orthopedics and Traumatology, Paracelsus Medical University, 90471 Nuremberg, Germany
| | - Bernd Kladny
- Fachklinik Herzogenaurach, D-91074 Herzogenaurach, Germany
| | - Wolfram Mittelmeier
- Orthopedic Clinic and Policlinic, University Rostock Medical Center, 18057 Rostock, Germany
| |
Collapse
|
3
|
Berger K, Schiefner F, Rudolf M, Awiszus F, Junne F, Vogel M, Lohmann CH. Long-term effects of doping with anabolic steroids during adolescence on physical and mental health. Orthopadie (Heidelb) 2024:10.1007/s00132-024-04498-3. [PMID: 38653791 DOI: 10.1007/s00132-024-04498-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 03/13/2024] [Indexed: 04/25/2024]
Abstract
BACKGROUND Systematic doping programs like in the GDR were applied in adolescent competitive athletes to induce supramaximal athletic performance. The substances had adverse somatic and psychological effects. The psychological development of the young athletes was impaired and they suffered in adulthood from long-term effects and secondary diseases even years after the doping period. METHOD The study compared three groups: competitive athletes with doping (I), competitive athletes without doping (II) and persons with no sports activities (III). Somatic and psychological diseases were analyzed to identify the adverse effects of doping in the most vulnerable phase of development in adolescence. Participants were asked to supply a patient history and completed a questionnaire with standardized psychological tests. RESULTS The doping cohort had a higher rate of somatic diseases, psychological disorders and social and professional difficulties. The differences were gender-specific with males more often having impaired liver function, depression, tumors and difficulties associated with the workplace . The doping group reported more emotional and physical neglect during childhood. They proved to be less optimistic but more pessimistic, to perceive less social support and to be more depressive. The study identified less extraversion and more neuroticism. Posttraumatic stress disorder (PTSD) occurred in a small number of participants in the doping group. Doping is associated with psychiatric variables. Predictors were the subscale identifying feelings of the Toronto alexithymia scale 20 (TAS-20), the sense of coherence and the Beck depression inventory 2 (BDI-II) and the Beck depression inventory (BDI). CONCLUSION Physical and psychosocial effects imply correlation with the application of doping substances but might not only be due to the side effects of these substances but also caused by the system, which exerts great psychological pressure and stress during adolescence, a highly vulnerable phase.
Collapse
Affiliation(s)
- K Berger
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Leipziger Str. 44, 39120, Magdeburg, Germany.
| | - F Schiefner
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Leipziger Str. 44, 39120, Magdeburg, Germany
| | - M Rudolf
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Leipziger Str. 44, 39120, Magdeburg, Germany
| | - F Awiszus
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Leipziger Str. 44, 39120, Magdeburg, Germany
| | - F Junne
- Department for Psychosomatic and Psychotherapy, Otto-von-Guericke University, Magdeburg, Germany
| | - M Vogel
- Department for Psychosomatic and Psychotherapy, Otto-von-Guericke University, Magdeburg, Germany
| | - C H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Leipziger Str. 44, 39120, Magdeburg, Germany
| |
Collapse
|
4
|
Jahn J, Halm-Pozniak A, Klutzny M, Noll M, Stärke C, Lohmann CH, Bertrand J. Collagen 1 gel may improve the regenerative capacity of minced adult and preosteoarthritic cartilage. Knee Surg Sports Traumatol Arthrosc 2024; 32:821-828. [PMID: 38415965 DOI: 10.1002/ksa.12101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 02/10/2024] [Accepted: 02/12/2024] [Indexed: 02/29/2024]
Abstract
PURPOSE Minced cartilage implantation (MCI) is an evolving technique for the treatment of osteochondral lesions. It was hypothesised that mincing of cartilage may affect chondrocyte viability and phenotype and that embedding in collagen 1 gel results in an improved outcome. The objective of this study was to evaluate the impact of cartilage mincing and whether collagen 1 gel mediates beneficial effects on the chondrocyte phenotype and viability. METHODS Human cartilage samples from 11 patients undergoing total knee arthroplasty were collected and minced according to the MCI protocol. Minced cartilage was cultured for 1 week with and without embedding in collagen 1 gel and was compared with unminced cartilage flakes as control. Quantitative reverse transcription-PCR and immunohistochemical staining for the chondrocyte marker genes SOX9, COL2, ACAN, COL10 and MMP13 were used to examine the chondrocyte phenotype. Cell death was assessed by the terminal deoxynucleotidyl transferase dUTP nick-end labeling assay. RESULTS Increased chondrocyte cell death of cultured cartilage after mincing was observed. Chondrocytes from minced cartilage exhibited significantly decreased expression and protein levels of homeostatic and hypertrophic chondrocyte markers. Embedding in collagen 1 gel showed no positive effect on viability. However, remarkable is the increased expression of ACAN and the preserved protein level of SOX9 in the collagen 1-embedded minced cartilage. CONCLUSIONS This study shows that the mincing of cartilage leads to increased chondrocyte death and decreased expression of chondrocyte phenotypic marker genes after 7 days. The use of collagen 1 gel may improve the stability of the phenotype, which needs to be further elucidated. LEVEL OF EVIDENCE Level III (therapeutic).
Collapse
Affiliation(s)
- Jannik Jahn
- Department of Orthopedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | | | - Marcus Klutzny
- Department of Orthopedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Michaela Noll
- Department of Orthopedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
- Meidrix biomedicals GmbH, Esslingen, Germany
| | - Christian Stärke
- Department of Orthopedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Christoph H Lohmann
- Department of Orthopedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Jessica Bertrand
- Department of Orthopedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| |
Collapse
|
5
|
Halm-Pozniak A, Riediger C, Kopsch E, Awiszus F, Lohmann CH, Berth A. Influence of humeral position of the Affinis short® stemless shoulder arthroplasty system on long-term survival and clinical outcome. J Shoulder Elbow Surg 2024:S1058-2746(24)00191-5. [PMID: 38514008 DOI: 10.1016/j.jse.2024.01.051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/03/2023] [Revised: 01/23/2024] [Accepted: 01/30/2024] [Indexed: 03/23/2024]
Abstract
BACKGROUND The purpose of this study was to evaluate the influence of humeral position of Affinis short implant in stemless anatomic total shoulder arthroplasties (STSA) on clinical and radiological results and mid- to long-term survival in the treatment of primary osteoarthritis (OA) of the shoulder. METHODS 80 patients treated with a stemless shoulder arthroplasty for OA of the shoulder were evaluated with a mean follow-up (FU) of 92 ± 14 months (range 69 to 116 months) by Constant (CS)-Score, Disability of Shoulder, Arm and Hand (DASH)-Score and active range of motion (ROM). Radiographic assessment for bone adaptations and humeral implant position was performed by plain X-rays. Determination of pre- and postoperative center of rotation (COR) was used to assess the restoration of the geometry of the humeral head. The appraisal of proper humeral component positioning was correlated with the functional outcomes. A Kaplan-Meier analysis was calculated, investigating the influence of humeral implant position compared to survival time. Complications were noted. RESULTS The ROM (p < 0.001), CS-Score (p < 0.001) and DASH-Score (p < 0.001) showed significant improvements after surgery for the entire series. The COR restoration was anatomical in 75 % (n = 60) of all implants and in 25 % (n = 20) non-anatomical (pre- and postoperative COR deviation of 2.7 ± 1.8 mm vs. 5.1 ± 3.2 mm, p = 0.0380). The humeral component position did not affect the functional outcome whereas the ten-year unadjusted cumulative survival rate for the anatomic group was significant higher in comparison with the non-anatomical group (96.7 % vs. 75 %, p = 0.002). The radiological evaluation revealed minor periprosthetic bone adaptions in various forms without clinical significance or further intervention. No revision was necessary due to a failed fixation of the stemless humeral component. CONCLUSIONS Regarding primary OA of the shoulder, STSA derives excellent long-term survival and clinical outcome. These types of implants are able to restore the geometry of the humeral head. Non-anatomical reconstruction may influence the survival over a long-term period on different pathways. Further studies are necessary to elucidate the effect of humeral component position in STSA on functionality, pain and implant survival rate.
Collapse
Affiliation(s)
- Agnieszka Halm-Pozniak
- Department of Orthopaedic Surgery, Otto-von-Guericke-University, Leipziger Str. 44, 39120 Magdeburg, Germany.
| | - Christian Riediger
- Department of Orthopaedic Surgery, Otto-von-Guericke-University, Leipziger Str. 44, 39120 Magdeburg, Germany
| | - Elisabeth Kopsch
- Department of Orthopaedic Surgery, Otto-von-Guericke-University, Leipziger Str. 44, 39120 Magdeburg, Germany
| | - Friedemann Awiszus
- Department of Orthopaedic Surgery, Otto-von-Guericke-University, Leipziger Str. 44, 39120 Magdeburg, Germany
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke-University, Leipziger Str. 44, 39120 Magdeburg, Germany
| | - Alexander Berth
- Department of Orthopaedic Surgery, Otto-von-Guericke-University, Leipziger Str. 44, 39120 Magdeburg, Germany
| |
Collapse
|
6
|
Bormann T, Kretzer JP, Jaeger S, Lohmann CH. Is taper corrosion in modular revision hip stem junctions associated with patient or implant specific factors? A retrieval analysis. J Mech Behav Biomed Mater 2024; 150:106326. [PMID: 38141361 DOI: 10.1016/j.jmbbm.2023.106326] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Revised: 12/04/2023] [Accepted: 12/11/2023] [Indexed: 12/25/2023]
Abstract
Implant modularity within revision total hip arthroplasty (THA) offers multiple implant configurations and allows surgeons a high intraoperative flexibility to restore functionality to the patients joint, even in complex revision cases. However, a rare but devastating complication for patients, clinicians and manufacturers presenting a breakage of the taper junction between the distal stem and the proximal implant part. Aside from implant and patient specific risk factors, corrosion and fretting at the stem junctions have been associated with taper failure. Whether corrosive processes are a precursor of failure or rather an accompaniment of material fatigue is thereby still unclear. Therefore, this study aims to investigate the incidence of taper corrosion in a collection of 17 retrievals from a single type (MRP-Titan, Peter Brehm GmbH) and on the correlation of taper corrosion to implant and patient specific factors. None of the implants was revised for problems related to the taper junction, corrosion or the implant itself. The modular stem junction of all retrievals was visually rated with respect to corrosion, fretting and surface contamination. Additionally, the stability of taper junctions of retrievals where the proximal part with the neck was still assembled to the stem was determined by measuring the loosening moment of the securing screw and the push-out-force for taper dissociation. There was no difference between the mean push-out-force of the retrievals (14 kN ± 1.2 kN) and new reference samples (12.6 kN ± 0.5 kN). Approximately one third of the investigated retrievals showed considerable taper corrosion. The extent of corrosion increased with time in vivo and contamination of the neck piece, while it decreased with the loosening moment of the locking screw. The parameters femoral head offset, neck piece length, lateralized neck pieces, obesity of patients and septic/aseptic revision were not correlated to taper corrosion. Taper corrosion seems to occur regularly in modular taper junctions and is not necessarily connected to taper failure. A correct assembly of the junction and avoiding taper surface contamination during revision surgery is mandatory.
Collapse
Affiliation(s)
- Therese Bormann
- Heidelberg University Hospital, Department of Orthopaedics, Laboratory of Biomechanics and Implant Research, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany.
| | - J Philippe Kretzer
- Heidelberg University Hospital, Department of Orthopaedics, Laboratory of Biomechanics and Implant Research, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany
| | - Sebastian Jaeger
- Heidelberg University Hospital, Department of Orthopaedics, Laboratory of Biomechanics and Implant Research, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany
| | - Christoph H Lohmann
- Department of Orthopaedics, University Hospital Magdeburg, Otto-von-Guericke University, Leipziger Str. 44, 39120, Magdeburg, Germany
| |
Collapse
|
7
|
Halm-Pozniak A, Lohmann CH, Awiszus F, Rudolf M, Bertrand J, Berth A. Injection of autologous conditioned plasma combined with a collagen scaffold may improve the clinical outcome in shoulder impingement syndrome: a prospective study. Eur J Orthop Surg Traumatol 2023; 33:3623-3630. [PMID: 37253875 PMCID: PMC10651528 DOI: 10.1007/s00590-023-03595-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Accepted: 05/17/2023] [Indexed: 06/01/2023]
Abstract
BACKGROUND Shoulder impingement syndrome (SIS) is one of the most common diseases of the shoulder and can be addressed with various therapeutic concepts. Orthobiological agents such as platelet rich plasma with a low side effect rate gain importance in the conservative treatment of SIS. Currently, the knowledge about success rate influencing factors, such as the growth factors (GF) concentration or acromion type, is limited. The aim of this study was to analyze the clinical outcome in the therapy of external SIS using autologous conditioned plasma combined with recombinant human collagen scaffold (ACP/STR) injection in comparison with a corticosteroid-local anesthetic (CSA) injection. Additionally, the influence of potential limiting factors such as GF concentration, age and acromial morphology was proved. MATERIALS AND METHODS This prospective pseudo-randomized trial recruited 58 patients with external SIS who received an ultrasound-guided subacromial injection either an ACP/STR or a CSA followed by physical therapy. Follow-up (FU) was performed at 6 weeks, 3 and 6 months. The outcome was assessed with Constant-Murley score, disability of arm, shoulder and hand score and simple shoulder test. The concentration of GF was measured using ELISA. RESULTS During the FU, the improvement of outcome measures was observed with no differences between both groups. Shoulder force was significantly increased in the ACP/STR group (p < 0.01). We found no correlation between the amount of GF and age or gender in the ACP/STR patients. An acromion Bigliani type III predisposes for therapy failure (p < 0.001, OR = 56) in both treatment groups. CONCLUSIONS Patients with SIS benefit regarding to PROMs after both ACP/STR and CSA injection and physical therapy. Patients who received ACP/STR obtained superior improvement in force. The quantity of GF did not vary depending on the age, so that ACP/STR can be a treatment option for SIS in elderly patients with multimorbidity. The presence of an acromion type III seems to be a predictive factor for limited effectivity of injections in the clinical management of SIS.
Collapse
Affiliation(s)
- Agnieszka Halm-Pozniak
- Department of Orthopaedic Surgery, Otto-Von-Guericke-University Magdeburg, 44 Leipziger St., 39120, Magdeburg, Germany.
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto-Von-Guericke-University Magdeburg, 44 Leipziger St., 39120, Magdeburg, Germany
| | - Friedemann Awiszus
- Department of Orthopaedic Surgery, Otto-Von-Guericke-University Magdeburg, 44 Leipziger St., 39120, Magdeburg, Germany
| | - Margit Rudolf
- Department of Orthopaedic Surgery, Otto-Von-Guericke-University Magdeburg, 44 Leipziger St., 39120, Magdeburg, Germany
| | - Jessica Bertrand
- Department of Orthopaedic Surgery, Otto-Von-Guericke-University Magdeburg, 44 Leipziger St., 39120, Magdeburg, Germany
| | - Alexander Berth
- Department of Orthopaedic Surgery, Otto-Von-Guericke-University Magdeburg, 44 Leipziger St., 39120, Magdeburg, Germany
| |
Collapse
|
8
|
Herbster M, Müller E, Jahn J, Buchholz A, Tootsi K, Lohmann CH, Halle T, Bertrand J. In vivo corrosion on retrieved hip endoprostheses and in vitro effects of corrosion products on bone mineralization. Bone 2023; 175:116852. [PMID: 37473933 DOI: 10.1016/j.bone.2023.116852] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 07/14/2023] [Accepted: 07/17/2023] [Indexed: 07/22/2023]
Abstract
In vivo corrosion of modular endoprostheses remains a great concern, as the release of heavy metal ions can impair the implant's service life and the wellbeing of the patient. The detailed corrosion mechanisms that occur in vivo are so far not completely understood. In this context, the effects of implant released cobalt (Co) and chromium (Cr) ions on osteoblast mineralization and gene expression have not been investigated extensively. This comprehensive study aimed at furthering the understanding of in vivo implant corrosion from the clinical signs via prosthesis retrievals and histology of the synovial membranes down to the molecular processes instigated by corrosion products and its effects on bone mineralization. A detailed in vivo failure analysis was performed investigating 22 retrieved hip endoprostheses from different manufacturers and taper material combinations. The aim was to find a correlation of taper damage and especially corrosion to susceptible biomedical alloys and its effect on periprosthetic tissue as well as the clinical implant performance with regard to revision diagnosis and presence of radiolucent lines (RLL). A second part investigated the effects of Co and Cr ions on the in vitro mineralization process of osteoblasts. Cell cultures were exposed to relevant concentrations of CoCl2 and CrCl3 (0 μM, 100 μM, 200 μM) with and without addition of phosphate. Mineralization behavior was analyzed with Alizarin Red assay and Von Kossa staining of calcium depots, alkaline phosphatase activity of osteoblasts and gene expression was analyzed with real time quantitative PCR. The retrieval study provides evidence of in vivo fretting and crevice corrosion on all metallic tapers combined with either ceramic or metal femoral heads. Within the modular taper junctions, selective dissolution of the α phase occurred in wrought TiAl6V4 alloys, and etching of the fine-grained wrought CoCr28Mo6 alloy implants was observed in formed crevices. In addition, significant amounts of wear particles and corrosion products were detected in retrieved synovial membranes. An increased risk for the occurrence of a RLL in the proximal zones was determined for patients with a corroded mixed metal taper. Whereas Co ions have hardly any effects on mineralization, Cr ions cause a significant concentration dependent decrease in mineralization rate of osteoblasts. However, this effect is alleviated by addition of a phosphate source. Our data reveal that Cr ions depleted dissolved phosphates by forming an insoluble complex (CrPO4), which inhibits the phosphate dependent mineralization process. No significant effect of the heavy metal ions on osteoblast activity by means of alkaline phosphate activity as well as on gene expression is determined. This study broadens the understanding of in vivo corrosion of metallic modular implants and its clinically relevant effects on mineralization. Based on these findings, in vivo corrosion of CoCr28Mo6 endoprostheses should be limited to avoid inhibitory effects of Cr3+ on bone mineralization which can contribute to premature implant failure.
Collapse
Affiliation(s)
- Maria Herbster
- Institute of Materials and Joining Technology, Otto-von-Guericke University Magdeburg, Germany.
| | - Eva Müller
- Department of Orthopedic Surgery, Otto-von-Guericke University Magdeburg, Germany
| | - Jannik Jahn
- Department of Orthopedic Surgery, Otto-von-Guericke University Magdeburg, Germany
| | - Adrian Buchholz
- Department of Orthopedic Surgery, Otto-von-Guericke University Magdeburg, Germany
| | - Kaspar Tootsi
- Department of Orthopedic Surgery, Otto-von-Guericke University Magdeburg, Germany; Department of Traumatology and Orthopedics, University of Tartu, Tartu University Hospital, Tartu, Estonia
| | - Christoph H Lohmann
- Department of Orthopedic Surgery, Otto-von-Guericke University Magdeburg, Germany
| | - Thorsten Halle
- Institute of Materials and Joining Technology, Otto-von-Guericke University Magdeburg, Germany
| | - Jessica Bertrand
- Department of Orthopedic Surgery, Otto-von-Guericke University Magdeburg, Germany
| |
Collapse
|
9
|
Richter E, Lohmann CH, Dell’Accio F, Goettsch C, Bertrand J. Sortilin Is Upregulated in Osteoarthritis-Dependent Cartilage Calcification and Associated with Cellular Senescence. Int J Mol Sci 2023; 24:12343. [PMID: 37569721 PMCID: PMC10418692 DOI: 10.3390/ijms241512343] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Revised: 07/27/2023] [Accepted: 07/31/2023] [Indexed: 08/13/2023] Open
Abstract
Osteoarthritis (OA) is a chronic joint disease characterized by articular cartilage calcification, loss of articular cartilage, bone changes, pain, and disability. Cartilage calcification is one hallmark of OA and is predominantly caused by basic calcium crystals formed due to an imbalance of the pyrophosphate pathway. Sortilin is a transmembrane protein that contributes to vascular calcification in atherosclerosis by externalizing alkaline phosphatase (ALP)-containing vesicles. Calcification in atherosclerosis and osteoarthritis has been associated with cellular senescence. The aim of this study was to investigate the potential role of sortilin and senescence in osteoarthritis-dependent cartilage calcification. Osteoarthritic cartilage from human knee joints was collected after joint replacement, and samples were analyzed by immunohistochemistry and quantitative RT-PCR analysis. Human chondrocytes were treated with osteogenic medium for up to 21 days to induce calcification. Western blots for sortilin and ALP, as well as an ALP activity assay, were performed. Human chondrocytes were treated with mitomycin C to induce senescence, and sortilin expression was quantified at the protein and gene levels. Sections of knee joints from a murine model of osteoarthritis were stained for sortilin and p16 and analyzed by immunohistochemistry. Treatment of wild-type chondrocytes using an osteogenic medium similar to human chondrocytes was performed. Osteoarthritic cartilage from mouse and human knee joints showed an increased number of sortilin and p16-positive chondrocytes compared to healthy cartilage. This observation was corroborated by increased gene expression of sortilin and p16 in mild and moderate osteoarthritic cartilage samples. To investigate the mechanism of sortilin regulation, human chondrocytes were treated with osteogenic medium to induce calcification. Sortilin protein levels and expression were increased after 7 days of stimulation, whereas ALP levels and activity were upregulated after 21 days of stimulation. Similar observations were made in a murine osteoarthritis model. Mechanistically, senescent chondrocytes induced by mitomycin C showed an upregulation of sortilin and ALP gene expression compared to non-senescent chondrocytes. Our data indicate that sortilin and ALP are upregulated during cartilage calcification, which is associated with chondrocyte senescence and thus might contribute to the pathogenesis of osteoarthritis. Cellular senescence seems to induce sortilin expression.
Collapse
Affiliation(s)
- Elisabeth Richter
- Department of Orthopaedic Surgery, Otto von Guericke University Magdeburg, 39120 Magdeburg, Germany; (E.R.); (C.H.L.)
| | - Christoph H. Lohmann
- Department of Orthopaedic Surgery, Otto von Guericke University Magdeburg, 39120 Magdeburg, Germany; (E.R.); (C.H.L.)
| | - Francesco Dell’Accio
- William Harvey Research Institute, Queen Mary University London, London EC1M 6BQ, UK;
| | - Claudia Goettsch
- Department of Internal Medicine I-Cardiology, RWTH Aachen University, 52062 Aachen, Germany
| | - Jessica Bertrand
- Department of Orthopaedic Surgery, Otto von Guericke University Magdeburg, 39120 Magdeburg, Germany; (E.R.); (C.H.L.)
| |
Collapse
|
10
|
Halm-Pozniak A, Lohmann CH, Zagra L, Braun B, Gordon M, Grimm B. Best practice in digital orthopaedics. EFORT Open Rev 2023; 8:283-290. [PMID: 37158429 DOI: 10.1530/eor-23-0081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/10/2023] Open
Abstract
Digitization in orthopaedics and traumatology is an enormously fast-evolving field with numerous players and stakeholders. It will be of utmost importance that the different groups of technologists, users, patients, and actors in the healthcare systems learn to communicate in a language with a common basis. Understanding the requirements of technologies, the potentials of digital application, their interplay, and the combined aim to improve health of patients, would lead to an extraordinary chance to improve health care. Patients' expectations and surgeons' capacities to use digital technologies must be transparent and accepted by both sides. The management of big data needs tremendous care as well as concepts for the ethics in handling data and technologies have to be established while also considering the impact of withholding or delaying benefits thereof. This review focuses on the available technologies such as Apps, wearables, robotics, artificial intelligence, virtual and augmented reality, smart implants, and telemedicine. It will be necessary to closely follow the future developments and carefully pay attention to ethical aspects and transparency.
Collapse
Affiliation(s)
| | | | - Luigi Zagra
- IRCCS Istituto Ortopedico Galeazzi, Hip Department, Milan, Italy
| | - Benedikt Braun
- Department of Trauma and Reconstructive Surgery at the Eberhard Karls University Tübingen, BG Unfallklinik Tübingen, Germany
| | - Max Gordon
- Department of Clinical Sciences at Danderyd Hospital, Unit of Orthopedics, Karolinska Institutet, Stockholm, Sweden
| | - Bernd Grimm
- Department of Precision Health, Luxembourg Institute of Health, Human Motion, Orthopaedics, Sports Medicine, Digital Methods, Luxembourg
| |
Collapse
|
11
|
Döring J, Basten S, Ecke M, Herbster M, Kirsch B, Halle T, Lohmann CH, Bertrand J, Aurich J. Surface integrity modification of CoCrMo alloy by deep rolling in combination with sub-zero cooling as potential implant application. J Biomed Mater Res B Appl Biomater 2023; 111:946-957. [PMID: 36479964 DOI: 10.1002/jbm.b.35204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Revised: 10/05/2022] [Accepted: 11/16/2022] [Indexed: 12/14/2022]
Abstract
Alloys made of CoCrMo are well established as implants materials since decades in orthopedic surgery. The good mechanical properties, biocompatibility and especially the corrosion resistance are important rationales for the use of these alloys. Nevertheless, retrieved implants from revision surgery showed the occurrence of abrasion and corrosion. The wear mechanisms and the occurring corrosion processes might be reduced with a functionalization of the surface. The hexagonal phase of the cobalt chromium matrix plays an important role in the surface functionalization. It can be specifically transformed and set during the manufacturing process. One possibility for the induction of the transformation is the use of a deep rolling process in combination with a novel "sub-zero" cooling strategy during machining. The influence of force and temperature during the deep rolling process on the formation of the hexagonal Co-phase is examined in this study. The results from the targeted setting of the hexagonal Co-phase in the subsurface are shown. For this purpose, EBSD studies have been carried out to detect and quantify the proportion of Co-hex phase in the subsurface of the modified alloys. To analyze the mechanical properties, we measured the residual stress and hardness in the near surface layer under conditions close to the application. Furthermore, we performed biological tests to show a potential influence of the modification on the biocompatibility when using the sub-zero cooling approach. We observed no negative effect on the osteoblastic cell line which attached similarly to all tested surfaces. The investigations provide first insights into the potential use of "sub-zero" cooling in modifying orthopedic implant materials, but also the respective limits with regard to the surface functionalization. Deep rolling in combination with an innovative cooling strategy has a great potential to improve the mechanical properties of CoCr28Mo6 wrought alloy, by subsurface hardening and phase transformation.
Collapse
Affiliation(s)
- Joachim Döring
- Department of Orthopaedic Surgery, Medical Faculty, Otto-von-Guericke-University Magdeburg, Magdeburg, Germany
| | - Stephan Basten
- Institute for Manufacturing Technology and Production Systems, TU Kaiserslautern, Kaiserslautern, Germany
| | - Martin Ecke
- Institute of Materials and Joining Technology, Otto-von-Guericke-University Magdeburg, Magdeburg, Germany
| | - Maria Herbster
- Department of Orthopaedic Surgery, Medical Faculty, Otto-von-Guericke-University Magdeburg, Magdeburg, Germany.,Institute of Materials and Joining Technology, Otto-von-Guericke-University Magdeburg, Magdeburg, Germany
| | - Benjamin Kirsch
- Institute for Manufacturing Technology and Production Systems, TU Kaiserslautern, Kaiserslautern, Germany
| | - Thorsten Halle
- Institute of Materials and Joining Technology, Otto-von-Guericke-University Magdeburg, Magdeburg, Germany
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Medical Faculty, Otto-von-Guericke-University Magdeburg, Magdeburg, Germany
| | - Jessica Bertrand
- Department of Orthopaedic Surgery, Medical Faculty, Otto-von-Guericke-University Magdeburg, Magdeburg, Germany
| | - Jan Aurich
- Institute for Manufacturing Technology and Production Systems, TU Kaiserslautern, Kaiserslautern, Germany
| |
Collapse
|
12
|
Sühn T, Esmaeili N, Mattepu SY, Spiller M, Boese A, Urrutia R, Poblete V, Hansen C, Lohmann CH, Illanes A, Friebe M. Vibro-Acoustic Sensing of Instrument Interactions as a Potential Source of Texture-Related Information in Robotic Palpation. Sensors (Basel) 2023; 23:3141. [PMID: 36991854 PMCID: PMC10056323 DOI: 10.3390/s23063141] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/25/2023] [Revised: 03/02/2023] [Accepted: 03/09/2023] [Indexed: 06/19/2023]
Abstract
The direct tactile assessment of surface textures during palpation is an essential component of open surgery that is impeded in minimally invasive and robot-assisted surgery. When indirectly palpating with a surgical instrument, the structural vibrations from this interaction contain tactile information that can be extracted and analysed. This study investigates the influence of the parameters contact angle α and velocity v→ on the vibro-acoustic signals from this indirect palpation. A 7-DOF robotic arm, a standard surgical instrument, and a vibration measurement system were used to palpate three different materials with varying α and v→. The signals were processed based on continuous wavelet transformation. They showed material-specific signatures in the time-frequency domain that retained their general characteristic for varying α and v→. Energy-related and statistical features were extracted, and supervised classification was performed, where the testing data comprised only signals acquired with different palpation parameters than for training data. The classifiers support vector machine and k-nearest neighbours provided 99.67% and 96.00% accuracy for the differentiation of the materials. The results indicate the robustness of the features against variations in the palpation parameters. This is a prerequisite for an application in minimally invasive surgery but needs to be confirmed in realistic experiments with biological tissues.
Collapse
Affiliation(s)
- Thomas Sühn
- Department of Orthopaedic Surgery, Otto-von-Guericke University Magdeburg, 39120 Magdeburg, Germany
- SURAG Medical GmbH, 39118 Magdeburg, Germany
| | | | - Sandeep Y. Mattepu
- INKA Innovation Laboratory for Image Guided Therapy, Otto-von-Guericke University Magdeburg, 39120 Magdeburg, Germany
| | | | - Axel Boese
- INKA Innovation Laboratory for Image Guided Therapy, Otto-von-Guericke University Magdeburg, 39120 Magdeburg, Germany
| | - Robin Urrutia
- Instituto de Acústica, Facultad de Ciencias de la Ingeniería, Universidad Austral de Chile, Valdivia 5111187, Chile
| | - Victor Poblete
- Instituto de Acústica, Facultad de Ciencias de la Ingeniería, Universidad Austral de Chile, Valdivia 5111187, Chile
| | - Christian Hansen
- Research Campus STIMULATE, Otto-von-Guericke University Magdeburg, 39106 Magdeburg, Germany
| | - Christoph H. Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University Magdeburg, 39120 Magdeburg, Germany
| | | | - Michael Friebe
- INKA Innovation Laboratory for Image Guided Therapy, Otto-von-Guericke University Magdeburg, 39120 Magdeburg, Germany
- Department of Measurement and Electronics, AGH University of Science and Technology, 30-059 Kraków, Poland
- CIB—Center of Innovation and Business Development, FOM University of Applied Sciences, 45127 Essen, Germany
| |
Collapse
|
13
|
Brunken F, Senft T, Herbster M, Relja B, Bertrand J, Lohmann CH. CoNiCrMo Particles, but Not TiAlV Particles, Activate the NLRP3 Inflammasome in Periprosthetic Cells. Int J Mol Sci 2023; 24:ijms24065108. [PMID: 36982177 PMCID: PMC10048784 DOI: 10.3390/ijms24065108] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 02/22/2023] [Accepted: 03/01/2023] [Indexed: 03/11/2023] Open
Abstract
Aseptic loosening is the main reason for arthroplasty failure. The wear particles generated at the tribological bearings are thought to induce an inflammatory tissue response, leading to bone loss and the subsequent loosening of the implant. Different wear particles have been shown to activate the inflammasome, thereby contributing to an inflammatory milieu in the direct vicinity of the implant. The aim of this study was to investigate whether the NLRP3 inflammasome is activated by different metal particles in vitro and in vivo. Three different cell lines representing periprosthetic cell subsets (MM6, MG63 and Jurkat) were incubated with different amounts of TiAlV or CoNiCrMo particles. The activation of the NLRP3 inflammasome was determined through the detection of the caspase 1 cleavage product p20 in a Western blot. The formation of the inflammasome was also investigated in vivo using immunohistological staining for ASC in primary synovial tissues as well as tissues containing TiAlV and CoCrMo particles and in vitro after the stimulation of the cells. The results show that the CoCrMo particles induced ASC more markedly, as a readout for inflammasome formation in vivo, compared to TiAlV particular wear. The CoNiCrMo particles also induced ASC-speck formation in all the tested cell lines, which was not induced by the TiAlV particles. The Western blot shows that NRLP3 inflammasome activation, measured through caspase 1 cleavage, was increased only by the CoNiCrMo particles in the MG63 cells. We conclude from our data that the activation of the inflammasome is mainly driven by CoNiCrMo particles and less by TiAlV particles, indicating that different inflammatory pathways are activated by the different alloys.
Collapse
Affiliation(s)
- Fenna Brunken
- Department of Orthopaedic Surgery, Otto-von-Guericke-University, 39120 Magdeburg, Germany
| | - Tristan Senft
- Department of Orthopaedic Surgery, Otto-von-Guericke-University, 39120 Magdeburg, Germany
| | - Maria Herbster
- Department of Orthopaedic Surgery, Otto-von-Guericke-University, 39120 Magdeburg, Germany
- Institute of Materials and Joining Technology, Otto-von-Guericke-University, 39120 Magdeburg, Germany
| | - Borna Relja
- Department of Experimental Radiology, Otto-von-Guericke-University, 39120 Magdeburg, Germany
| | - Jessica Bertrand
- Department of Orthopaedic Surgery, Otto-von-Guericke-University, 39120 Magdeburg, Germany
- Correspondence: ; Tel.: +49-391-67-15804
| | - Christoph H. Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke-University, 39120 Magdeburg, Germany
| |
Collapse
|
14
|
Döring J, Buchholz A, Herbster M, Gehring J, Betke U, Chodór P, Zabrzyński J, Bertrand J, Lohmann CH, Łapaj Ł. Damage analysis of retrieved Biolox Ⓡdelta components used in hard and soft bearings. Acta Biomater 2023; 158:827-842. [PMID: 36599400 DOI: 10.1016/j.actbio.2022.12.055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Revised: 12/21/2022] [Accepted: 12/23/2022] [Indexed: 01/02/2023]
Abstract
This retrieval study included 43 Biolox delta explants (18 CoC, 25 CoP). Implants were examined macroscopically, whereby damage was evaluated using a semi quantitative scoring system. Confocal microscopy was used to examine wear related damage patterns of the articulating surfaces. Scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS) was used to analyze wear marks on the implant surface and wear debris in periprosthetic tissue samples. Raman spectroscopy and X-ray diffraction (XRD) were used to quantify monoclinic zirconia fractions. On all components, in vivo wear resulted predominantly in different damage patterns caused by metal transfer. In CoC bearings stripe wear was additionally detected, and some implants underwent severe damage due to component breakage. The wear scores were higher for CoC components, with no differences between the scores for CoC heads and liners. Wear features caused comparable roughening on implants from CoC and CoP bearings. SEM studies demonstrated that most wear marks were caused by metal debris released from implant components. Grain pull-out was observed in stripe wear regions. Monoclinic phase shift was observed in a similar quantity on components from CoP and CoC bearings. The increase of monoclinic zirconia content around metal deposits was minimal and was more pronounced in areas of stripe wear. The results of this study indicate, that ZTA components in general undergo minimal wear in both, CoC and CoP bearings, however, it is more pronounced in the former. Metal deposits, as the most common wear feature, have no significant effect on monoclinic phase transition. STATEMENT OF SIGNIFICANCE: In this paper, we classify all damage patterns macroscopically according to an established scoring system and assess them regarding surface roughness (confocal microscopy) and monoclinic phase content (Raman spectroscopy) in order to derive the severity for patients. We compare hard-hard and hard-soft bearings and relate damage patterns with metal transfer based on SEM/EDS examinations. Furthermore, we work out correlations between patient-specific data, cause of revision and the physical condition of each individual sample Our cohort consists of 43 Biolox delta retrievals, a comparatively large quantity. In addition, we address current topics such as metal transfer and, based on the classification of damage patterns, provide incentives and/or meaningful focal points for further research.
Collapse
Affiliation(s)
- Joachim Döring
- Department of Orthopaedic Surgery, Otto-von-Guericke-University, Magdeburg, Germany.
| | - Adrian Buchholz
- Department of Orthopaedic Surgery, Otto-von-Guericke-University, Magdeburg, Germany
| | - Maria Herbster
- Institute of Materials and Joining Technology, Otto-von-Guericke-University, Magdeburg, Germany
| | - Jennifer Gehring
- Department of Orthopaedic Surgery, Otto-von-Guericke-University, Magdeburg, Germany
| | - Ulf Betke
- Institute of Materials and Joining Technology, Otto-von-Guericke-University, Magdeburg, Germany
| | - Paweł Chodór
- Department of General Orthopaedics, Musculoskeletal Oncology and Trauma Surgery, Poznań, Poland
| | - Jan Zabrzyński
- Faculty of Medicine, Nicolas Copernicus University, Toruń, Collegium Medicum in Bydgoszcz, Poland
| | - Jessica Bertrand
- Department of Orthopaedic Surgery, Otto-von-Guericke-University, Magdeburg, Germany
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke-University, Magdeburg, Germany
| | - Łukasz Łapaj
- Department of General Orthopaedics, Musculoskeletal Oncology and Trauma Surgery, Poznań, Poland
| |
Collapse
|
15
|
Lohmann CH, Holzapfel BM. [Implant-associated complications in hip arthroplasty: biological reactions of the "microenvironment" to the implant]. Orthopadie (Heidelb) 2023; 52:177. [PMID: 36894645 DOI: 10.1007/s00132-023-04350-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Subscribe] [Scholar Register] [Accepted: 01/16/2023] [Indexed: 03/11/2023]
Affiliation(s)
- Christoph H Lohmann
- Medizinische Fakultät, Otto-von-Guericke-Universität Magdeburg, Leipziger Str. 44, 39120, Magdeburg, Deutschland.
| | - Boris M Holzapfel
- Klinik für Orthopädie und Unfallchirurgie, Muskuloskelettales Universitätszentrum München (MUM), Universitätsklinikum, LMU München, Marchioninistr. 15, 81377, München, Deutschland.
| |
Collapse
|
16
|
Costa MD, Donner S, Bertrand J, Pop OL, Lohmann CH. Hypersensitivity and lymphocyte activation after total hip arthroplasty. Orthopadie (Heidelb) 2023; 52:214-221. [PMID: 36820851 DOI: 10.1007/s00132-023-04349-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 01/16/2023] [Indexed: 02/24/2023]
Abstract
In the last decades total hip arthroplasty (THA) has become a standard procedure with many benefits but also a few still unsolved complications, which can lead to surgical revision in 19-23% of cases. Thus, aseptic loosening and metal hypersensitivity remain challenges. The phenomenon of wear debris causes chronic inflammation, which produces osteolysis and aseptic loosening. Wear debris promotes osteoclast production and inhibits osteoblasts by secretion of pro-inflammatory cytokines. Micro-abrasions can be induced by abrasive, adhesive and fatigue wear and cause a liberation of metal ions, which lead to another immune response elicited mostly by macrophages. Another reaction in the neocapsule can be a type IV hypersensitivity reaction to various alloys, containing metals such as nickel, cobalt and chromium. Patch testing and the lymphocyte transformation test (LTT) are not the best diagnostic possibilities to exclude a postoperative hypersensitivity reaction, because of the different alignment of the epicutaneous cells compared to the periprosthetic deep tissue. This hypersensitivity reaction is mostly induced by cytokines, which are secreted by macrophages rather than lymphocytes. In cell cultures and in animal studies, multipotent mesenchymal stem cells (MSC) have been shown to play a role in improving initial implant integration, to limit periprosthetic osteolysis and also to reconstitute peri-implant bone stock during implant revision. Thus, MSC might be used in the future to prolong the durability of THA. A better understanding of the interactions between primary chronic inflammation, corrosion, osteolysis and hypersensitivity is mandatory to develop new therapeutic strategies, aiming at the reduction of the incidence of implant failures. In this article the underlying immunological mechanisms to aseptic loosening are presented.
Collapse
Affiliation(s)
- Maximilian D Costa
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Leipziger Str. 44, 39120, Magdeburg, Germany
- Department of Morphological Sciences, Faculty of Medicine and Pharmacy, University of Oradea, Oradea, Romania
| | - Stefanie Donner
- Centre for Musculoskeletal Surgery, Charité-University Medicine, Berlin, Germany
| | - Jessica Bertrand
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Leipziger Str. 44, 39120, Magdeburg, Germany
| | - Ovidiu-Laurean Pop
- Department of Morphological Sciences, Faculty of Medicine and Pharmacy, University of Oradea, Oradea, Romania
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Leipziger Str. 44, 39120, Magdeburg, Germany.
| |
Collapse
|
17
|
Meinshausen AK, Färber J, Illiger S, Macor P, Lohmann CH, Bertrand J. C9 immunostaining as a tissue biomarker for periprosthetic joint infection diagnosis. Front Immunol 2023; 14:1112188. [PMID: 36895567 PMCID: PMC9989178 DOI: 10.3389/fimmu.2023.1112188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Accepted: 02/01/2023] [Indexed: 02/23/2023] Open
Abstract
Background Culture-negative periprosthetic joint infections (PJI) are often false diagnosed as aseptic implant failure leading to unnecessary revision surgeries due to repeated infections. A marker to increase the security of e PJI diagnosis is therefore of great importance. The aim of this study was to test C9 immunostaining of periprosthetic tissue as a novel tissue-biomarker for a more reliable identification of PJI, as well as potential cross-reactivity. Method We included 98 patients in this study undergoing septic or aseptic revision surgeries. Standard microbiological diagnosis was performed in all cases for classification of patients. Serum parameters including C-reactive protein (CRP) serum levels and white blood cell (WBC) count were included, and the periprosthetic tissue was immunostained for C9 presence. The amount of C9 tissue staining was evaluated in septic versus aseptic tissue and the amount of C9 staining was correlated with the different pathogens causing the infection. To exclude cross-reactions between C9 immunostaining and other inflammatory joint conditions, we included tissue samples of a separate cohort with rheumatoid arthritis, wear particles and chondrocalcinosis. Results The microbiological diagnosis detected PJI in 58 patients; the remaining 40 patients were classified as aseptic. Serum CRP values were significantly increased in the PJI cohort. Serum WBC was not different between septic and aseptic cases. We found a significant increase in C9 immunostaining in the PJI periprosthetic tissue. To test the predictive value of C9 as biomarker for PJI we performed a ROC analyses. According to the Youden's criteria C9 is a very good biomarker for PJI detection with a sensitivity of 89% and a specificity of 75% and an AUC of 0.84. We did not observe a correlation of C9 staining with the pathogen causing the PJI. However, we observed a cross reactivity with the inflammatory joint disease like rheumatoid arthritis and different metal wear types. In addition, we did not observe a cross reactivity with chondrocalcinosis. Conclusion Our study identifies C9 as a potential tissue-biomarker for the identification of PJI using immunohistological staining of tissue biopsies. The use of C9 staining could help to reduce the number of false negative diagnoses of PJI.
Collapse
Affiliation(s)
- Ann-Kathrin Meinshausen
- Department of Orthopaedic Surgery, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| | - Jacqueline Färber
- Institute of Medical Microbiology, Infection Control and Prevention, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| | - Sebastian Illiger
- Department of Orthopaedic Surgery, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| | - Paolo Macor
- Department of Life Sciences, University of Trieste, Trieste, Italy
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University Magdeburg, Magdeburg, Germany.,Health Campus Immunology, Infectiology and Inflammation, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| | - Jessica Bertrand
- Department of Orthopaedic Surgery, Otto-von-Guericke University Magdeburg, Magdeburg, Germany.,Health Campus Immunology, Infectiology and Inflammation, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| |
Collapse
|
18
|
Cohen DJ, Lohmann CH, Scott KM, Olson LC, Boyan BD, Schwartz Z. Osseointegration and Remodeling of Mineralized Bone Graft Are Negatively Impacted by Prior Treatment with Bisphosphonates. J Bone Joint Surg Am 2022; 104:1750-1759. [PMID: 35983995 PMCID: PMC10007861 DOI: 10.2106/jbjs.21.01489] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Bisphosphonates limit resorption by inhibiting osteoclast formation and activation. They are removed during preparation of demineralized bone matrix (DBM) particles, but it is not known if osteogenesis and incorporation of mineralized bone allografts from patients treated with oral bisphosphonates are affected in vivo. METHODS Human block allografts from 3 bisphosphonate-treated donors and 3 age and sex-matched control donors who had not received bisphosphonates were obtained (Musculoskeletal Transplant Foundation); one-half from each donor was demineralized. In the first study, 3 × 2-mm mineralized and demineralized cylindrical grafts were implanted bilaterally in the femoral metaphysis of 56 rats. In the second study, samples from each group were pooled, prepared as particles, and implanted bilaterally in the femoral marrow canal of 24 rats. Osseointegration, defined as native bone in contact with allograft, was assessed at 10 weeks by micro-computed tomography (CT) and histomorphometry. RESULTS Micro-CT showed greater bone volume in sites treated with demineralized samples compared with the control mineralized and bisphosphonate-exposed mineralized samples. More new bone was generated along the cortical-endosteal interface compared with mineralized samples. Histology showed significantly less new bone in contact with the mineralized bisphosphonate-exposed allograft (10.4%) compared with mineralized samples that did not receive bisphosphonates (22.8%) and demineralized samples (31.7% and 42.8%). A gap was observed between native bone and allograft in the bisphosphonate-exposed mineralized samples (0.50 mm 2 ). The gap area was significantly greater compared with mineralized samples that did not receive bisphosphonates (0.16 mm 2 ) and demineralized samples (0.10 and 0.03 mm 2 ). CONCLUSIONS Mineralized allografts were osseointegrated, but not remodeled or replaced by living bone, preventing full regeneration of the bone defect. Prior treatment of the donor with bisphosphonates affected osteogenesis, preventing osteointegration and remodeling of the allograft into the regenerating bone. CLINICAL RELEVANCE Clinical use of mineralized allografts from patients who had received bisphosphonate therapy needs to be evaluated; in this animal model, such grafts were not integrated into the host bone or remodeled, and full regeneration of the bone defects was prevented.
Collapse
Affiliation(s)
- D Joshua Cohen
- Department of Biomedical Engineering, College of Engineering, Virginia Commonwealth University, Richmond, Virginia
| | - Christoph H Lohmann
- Department of Orthopaedics, Otto-von-Guericke University, Magdeburg, Germany
| | - Kayla M Scott
- Department of Biomedical Engineering, College of Engineering, Virginia Commonwealth University, Richmond, Virginia
| | - Lucas C Olson
- Department of Biomedical Engineering, College of Engineering, Virginia Commonwealth University, Richmond, Virginia
| | - Barbara D Boyan
- Department of Biomedical Engineering, College of Engineering, Virginia Commonwealth University, Richmond, Virginia.,Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Georgia
| | - Zvi Schwartz
- Department of Biomedical Engineering, College of Engineering, Virginia Commonwealth University, Richmond, Virginia.,Department of Periodontics, University of Texas Health Science Center at San Antonio, San Antonio, Texas
| |
Collapse
|
19
|
Vogel M, Binneböse M, Wallis H, Lohmann CH, Junne F, Berth A, Riediger C. The Unhappy Shoulder: A Conceptual Review of the Psychosomatics of Shoulder Pain. J Clin Med 2022; 11:jcm11185490. [PMID: 36143137 PMCID: PMC9504378 DOI: 10.3390/jcm11185490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 09/09/2022] [Accepted: 09/14/2022] [Indexed: 11/16/2022] Open
Abstract
INTRODUCTION Chronic pain is a multifaceted disorder genuinely entangled with psychic and psychosomatic symptoms, which are typically involved in the processes of chronification. The impingement syndrome of the shoulder is no exception to this rule, but several studies have shown respective peculiarities among those with pain and impingement of the shoulder. Notably, chronic pain is a lateralized experience, and, similarly, its psychosomatic correlates may be attached to the hemispheres functionally. AIM The present review therefore gives an overview of the respective findings, with regard not only to psychopathology, but also to personality factors and psychologic trauma, since the latter are reportedly associated with chronic pain. Moreover, we acknowledge symmetry as a possible pathogenic factor. METHODS This narrative review followed the current standards for conducting narrative studies. Based on prior findings, our research strategy included the relevance of psychotraumatologic and symmetrical aspects, as well as comorbidity. We retrieved the relevant literature reporting on the impact of psychopathology as well as personality features on shoulder pain, as published up to January 2022 from the Medline database (1966-2022). Study selecton: We included numerous studies, and considered the contextual relevance of studies referring to the neuropsychosomatics of chronic pain. RESULTS Pain-specific fears, depression, and anxiety are important predictors of shoulder pain, and the latter is generally overrepresented in those with trauma and PTSD. Moreover, associations of shoulder pain with psychological variables are stronger as regards surgical therapies as compared to conservative ones. This may point to a specific and possibly trauma-related vulnerability for perioperative maladaptation. Additionally, functional hemispheric lateralization may explain some of those results given that limb pain is a naturally lateralized experience. Not least, psychosocial risk factors are shared between shoulder pain and its physical comorbidities (e.g., hypertension), and the incapacitated state of the shoulder is a massive threat to the function of the human body as a whole. CONCLUSIONS This review suggests the involvement of psychosomatic and psychotraumatologic factors in shoulder impingement-related chronic pain, but the inconclusiveness and heterogeneity of the literature in the field is possibly suggestive of other determinants such as laterality.
Collapse
Affiliation(s)
- Matthias Vogel
- Department of Psychosomatic Medicine and Psychotherapy, Otto-von Guericke-University of Magdeburg, 39120 Magdeburg, Germany
- Correspondence: ; Tel.: +49391-6714200; Fax: +49391-6714202
| | - Marius Binneböse
- Department of Psychosomatic Medicine and Psychotherapy, Otto-von Guericke-University of Magdeburg, 39120 Magdeburg, Germany
| | - Hannah Wallis
- Department of Psychosomatic Medicine and Psychotherapy, Otto-von Guericke-University of Magdeburg, 39120 Magdeburg, Germany
| | - Christoph H. Lohmann
- Department of Orthopedic Surgery, Otto-von Guericke-University of Magdeburg, 39120 Magdeburg, Germany
| | - Florian Junne
- Department of Psychosomatic Medicine and Psychotherapy, Otto-von Guericke-University of Magdeburg, 39120 Magdeburg, Germany
| | - Alexander Berth
- Department of Orthopedic Surgery, Otto-von Guericke-University of Magdeburg, 39120 Magdeburg, Germany
| | - Christian Riediger
- Department of Orthopedic Surgery, Otto-von Guericke-University of Magdeburg, 39120 Magdeburg, Germany
| |
Collapse
|
20
|
Herbster M, Harnisch K, Kriegel P, Heyn A, Krüger M, Lohmann CH, Bertrand J, Halle T. Microstructural Modification of TiAl6V4 Alloy to Avoid Detrimental Effects Due to Selective In Vivo Crevice Corrosion. Materials (Basel) 2022; 15:5733. [PMID: 36013867 PMCID: PMC9414096 DOI: 10.3390/ma15165733] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Revised: 08/16/2022] [Accepted: 08/17/2022] [Indexed: 06/15/2023]
Abstract
TiAl6V4 wrought alloy is a standard material used for endoprostheses due to its ideal characteristics in terms of osseointegration. However, the insufficient wear and crevice corrosion resistance of TiAl6V4 are limiting factors that can cause clinical problems. Therefore, the objective of this study was to analyze and identify suitable phases and microstructural states of TiAl6V4 alloy with advantageous implant properties by thermal treatments. By varying the temperature and cooling rate, four heat treatment strategies were derived that produced different microstructural states that differed in morphology, arrangement and proportions of phases present. All TiAl6V4 modifications were characterized regarding their microstructure, mechanical, corrosive and tribological properties, as well as cell adhesion. The acicular, martensitic microstructure achieves a significant hardness increase by up to 63% and exhibits improved corrosion and wear resistance compared to the forged condition. Whereas the modified microstructures showed similar electrochemical properties in polarization tests using different electrolytes (PBS with H2O2 and HCl additives), selective α or β phase dissolution occurred under severe inflammatory crevice conditions after four weeks of exposure at 37 °C. The microstructurally selective corrosion processes resemble the damage patterns of retrieved Ti-based implants and provide a better understanding of clinically relevant in vivo crevice corrosion mechanisms. Furthermore, a microstructural effect on cell attachment was determined and is correlated to the size of the vanadium-rich β phase. These key findings highlight the relevance of an adapted processing of TiAl6V4 alloy to increase the longevity of implants.
Collapse
Affiliation(s)
- Maria Herbster
- Institute of Materials and Joining Technology, Otto-von-Guericke University, 39106 Magdeburg, Germany
| | - Karsten Harnisch
- Institute of Materials and Joining Technology, Otto-von-Guericke University, 39106 Magdeburg, Germany
| | - Paulina Kriegel
- Institute of Materials and Joining Technology, Otto-von-Guericke University, 39106 Magdeburg, Germany
| | - Andreas Heyn
- Institute of Materials and Joining Technology, Otto-von-Guericke University, 39106 Magdeburg, Germany
| | - Manja Krüger
- Institute of Materials and Joining Technology, Otto-von-Guericke University, 39106 Magdeburg, Germany
| | - Christoph H. Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University, 39120 Magdeburg, Germany
| | - Jessica Bertrand
- Department of Orthopaedic Surgery, Otto-von-Guericke University, 39120 Magdeburg, Germany
| | - Thorsten Halle
- Institute of Materials and Joining Technology, Otto-von-Guericke University, 39106 Magdeburg, Germany
| |
Collapse
|
21
|
Märtens N, März V, Bertrand J, Lohmann CH, Berth A. Radiological changes in shoulder osteoarthritis and pain sensation correlate with patients’ age. J Orthop Surg Res 2022; 17:277. [PMID: 35570309 PMCID: PMC9107673 DOI: 10.1186/s13018-022-03137-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Accepted: 04/19/2022] [Indexed: 11/18/2022] Open
Abstract
Purpose Osteoarthritis (OA) is one of the most common musculoskeletal disorders in the aging population. The correlation of radiographic OA severity, disability and pain is variable and inconsistent for the different joints. This study aims to elucidate the relationship between histological and radiological signs of shoulder OA with pain sensation and functional impairment to potentially adapt the recommendation for surgical treatment for primary total shoulder arthroplasty (TSA). Methods Forty-four patients with shoulder OA undergoing TSA using an anatomic stemless implant were included in this study. The radiological OA severity was scored pre-operatively on true ap X-rays according to the Kellgren–Lawrence score (KL-Score). Acromial types according to Bigliani were defined by pre-operative radiological images. The histological OA severity was determined according to the OARSI-Score using bone–cartilage sections from loaded areas of the humeral head. Pain was quantified using the visual analog scale (VAS). The functional status was assessed by the items “mobility” and “strength” out of the Constant–Murley score (CS Score). Demographic data including BMI, age, gender, diabetes mellitus and smoking were recorded. Results There was no correlation between radiographic and histological severity in shoulder OA. However, a correlation of age and the severity of radiological changes was observed. Further, pain did not correlate with histological or radiological scores, whereas it correlated with age and the presence of diabetes mellitus. The functional shoulder status (mobility, strength) correlated with the severity of radiological changes, but not with the histologic scoring, which correlated with nicotine abuse. Conclusion This study shows that increased age is the main determinant of radiological changes in shoulder OA, as well as pain. Therefore, age and pain sensation should be considered as important parameters for the recommendation for TSA. Supplementary Information The online version contains supplementary material available at 10.1186/s13018-022-03137-x.
Collapse
|
22
|
Vogel M, Binneböse M, Lohmann CH, Junne F, Berth A, Riediger C. Are Anxiety and Depression Taking Sides with Knee-Pain in Osteoarthritis? J Clin Med 2022; 11:jcm11041094. [PMID: 35207366 PMCID: PMC8876729 DOI: 10.3390/jcm11041094] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Revised: 02/12/2022] [Accepted: 02/16/2022] [Indexed: 12/03/2022] Open
Abstract
Introduction: Total knee arthroplasty (TKA) bears a potential of rendering patients unsatisfied with the operation as a result of negative affectivity related to osteoarthritis and TKA. Not only is pain a lateralized experience, but negative affect and other psychosomatic correlates of pain might also be processed on grounds of lateralization. Lateralization in this context is likely linked to the amygdalae, which display differential left/right patterns of association with psychopathology. What is noteworthy is that osteoarthritis itself is linked not only to negative effects but also to childhood abuse. Method: The present study tests lateralization of psychosomatic correlates of knee-pain using the brief symptom inventory-18 (BSI-18), the dissociative experiences scale (FDS-20), the pain catastrophizing scale (PCS), the Tampa scale of kinesiophobia (TSK), the childhood trauma screener (CTS) and WOMAC. More precisely, we were interested in predicting the side of operations by means of the above-mentioned constructs using binary logistic regression, based on 150 participants (78 left knees) awaiting TKA for knee-osteoarthritis. Results: Somatization (p = 0.003), childhood abuse (p = 0.04) and pain-catastrophizing (p = 0.04) predicted operations on the right side. Anxiety (p = 0.001) and kinesiophobia (p = 0.002) predicted operations on the left side. Conclusions: Knee-pain may be differentially modulated by its psychosomatic correlates as a result of lateralization and corresponding patterns of psychosomatic reagibility.
Collapse
Affiliation(s)
- Matthias Vogel
- Department of Psychosmatic Medicine and Psychotherapy, Otto-von-Guericke-University of Magdeburg, 39120 Magdeburg, Germany; (M.B.); (F.J.)
- Correspondence: ; Tel.: +49-391-6714200; Fax: +49-391-6714202
| | - Marius Binneböse
- Department of Psychosmatic Medicine and Psychotherapy, Otto-von-Guericke-University of Magdeburg, 39120 Magdeburg, Germany; (M.B.); (F.J.)
| | - Christoph H. Lohmann
- Department of Orthopedic Surgery, Otto-von-Guericke-University of Magdeburg, 39120 Magdeburg, Germany; (C.H.L.); (A.B.); (C.R.)
| | - Florian Junne
- Department of Psychosmatic Medicine and Psychotherapy, Otto-von-Guericke-University of Magdeburg, 39120 Magdeburg, Germany; (M.B.); (F.J.)
| | - Alexander Berth
- Department of Orthopedic Surgery, Otto-von-Guericke-University of Magdeburg, 39120 Magdeburg, Germany; (C.H.L.); (A.B.); (C.R.)
| | - Christian Riediger
- Department of Orthopedic Surgery, Otto-von-Guericke-University of Magdeburg, 39120 Magdeburg, Germany; (C.H.L.); (A.B.); (C.R.)
| |
Collapse
|
23
|
Herbster M, Rosemann P, Michael O, Harnisch K, Ecke M, Heyn A, Lohmann CH, Bertrand J, Halle T. Microstructure-dependent crevice corrosion damage of implant materials CoCr28Mo6, TiAl6V4 and REX 734 under severe inflammatory conditions. J Biomed Mater Res B Appl Biomater 2022; 110:1687-1704. [PMID: 35174958 DOI: 10.1002/jbm.b.35030] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 01/10/2022] [Accepted: 01/31/2022] [Indexed: 11/10/2022]
Abstract
Fretting corrosion is associated with increased risk of premature implant failure. In this complex in vivo corrosion system, the contribution of static crevice corrosion of the joined metal alloys is still unknown. The aim of this study was to develop a methodology for testing crevice corrosion behavior that simulates the physiological conditions of modular taper junctions and to identify critical factors on corrosion susceptibility. Samples of medical grade CoCr28Mo6 cast and wrought alloy, TiAl6V4 wrought alloy and REX 734 stainless steel were prepared metallographically and the microstructure was investigated using scanning electron microscopy (SEM). Crevice formers that mimic typical geometries of taper junctions were developed. Crevice corrosion immersion tests were performed in different physiological fluids (bovine serum or phosphate buffered saline with additives of 30 mM H2 O2 at pH = 1) for 4 weeks at 37°C. SEM with energy dispersive X-ray spectroscopy as well as focused ion beam were used to characterize the surface morphology, investigate present damages and identify the chemical composition of residues. Macroscopic inspection showed increased crevice corrosion susceptibility of TiAl6V4 and REX 734 under severe simulated inflammatory conditions. CoCr28Mo6 cast alloy exhibited degraded areas next to Cr- and Mo-rich precipitations that were located within the opposed crevices. The results indicate that aggressive electrolyte composition and crevice heights of 50-500 μm are critical influencing factors on crevice corrosion of biomedical alloys. Furthermore, manufacturing-related microstructure of common implant alloys determines the deterioration of corrosion resistance. The developed method should be used to enhance the corrosion resistance of common implant biomaterials by an adapted microstructure.
Collapse
Affiliation(s)
- Maria Herbster
- Institute of Materials and Joining Technology, Otto-von-Guericke University, Magdeburg, Germany.,Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Paul Rosemann
- Institute of Materials and Joining Technology, Otto-von-Guericke University, Magdeburg, Germany.,Institute of Technology and Production in Mechanical Engineering, HTWK University of Applied Sciences, Leipzig, Germany
| | - Oliver Michael
- Institute of Materials and Joining Technology, Otto-von-Guericke University, Magdeburg, Germany
| | - Karsten Harnisch
- Institute of Materials and Joining Technology, Otto-von-Guericke University, Magdeburg, Germany
| | - Martin Ecke
- Institute of Materials and Joining Technology, Otto-von-Guericke University, Magdeburg, Germany
| | - Andreas Heyn
- Institute of Materials and Joining Technology, Otto-von-Guericke University, Magdeburg, Germany
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Jessica Bertrand
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Thorsten Halle
- Institute of Materials and Joining Technology, Otto-von-Guericke University, Magdeburg, Germany
| |
Collapse
|
24
|
Herbster M, Berth A, Märtens N, Robra M, Welzel F, Dallmann F, Lohmann CH, Halle T, Bertrand J, Döring J. Intraoperative assembly of anatomical shoulder prosthesis frequently results in malalignment of the modular taper junction. J Orthop Res 2021; 39:2485-2496. [PMID: 33368644 DOI: 10.1002/jor.24975] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/29/2020] [Revised: 12/08/2020] [Accepted: 12/14/2020] [Indexed: 02/04/2023]
Abstract
Anatomical shoulder arthroplasties (ASA) may fail because of micromotion at the modular taper junction causing wear due to fretting. Sufficient taper strength can reduce micromotion and potential reasons for failure. However, there are no normative standards for a safe assembly process performed intraoperatively by the surgeon. The purpose of this study is to determine the effect of common intraoperative assembly strategies and to identify critical influencing factors on taper stability. ASA with standard and stemless humeral component in combination with concentric Al2 O3 heads and eccentric CoCr28Mo6 alloyed humeral heads were tested. Taper angles and surface roughness were determined. Force magnitudes and impact directions were recorded using a sensorized head impactor and a three-dimensional force measuring platform. Subsequently, the axial pull-off forces were measured and taper engagement areas were macroscopically evaluated. In comparison to standard stem tapers that were impacted with an assembly device, stemless tapers were impacted into the artificial bone with significantly lower forces. Taper strength correlates to maximum impact force and was higher for CoCr28Mo6 heads with a mean pull-off ratio of 0.56 than for Al2 O3 heads with 0.37. Interestingly, all tapers showed an asymmetric clamping behavior, due to tilting during impaction. This is caused by the variation of the resulting force vector and further promoted by humeral head eccentricity. Assembly technique markedly influences the force magnitude, impact direction, impulse, and consequently taper strength. The resulting force vector and head eccentricity were identified as potential risk factors for taper malalignment.
Collapse
Affiliation(s)
- Maria Herbster
- Institute of Materials and Joining Technology, Otto-von-Guericke University, Magdeburg, Germany
| | - Alexander Berth
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Nicole Märtens
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Marcel Robra
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Florian Welzel
- GFE-Gesellschaft für Fertigungstechnik und Entwicklung Schmalkalden e.V., Schmalkalden, Germany
| | | | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Thorsten Halle
- Institute of Materials and Joining Technology, Otto-von-Guericke University, Magdeburg, Germany
| | - Jessica Bertrand
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Joachim Döring
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| |
Collapse
|
25
|
Osmanski-Zenk K, Klinder A, Rimke C, Wirtz DC, Lohmann CH, Haas H, Kladny B, Mittelmeier W. Evaluation of the standard procedure for treatment of periprosthetic joint infections of total knee and hip arthroplasty: a comparison of the 2015 and 2020 census in total joint replacement centres in Germany. BMC Musculoskelet Disord 2021; 22:791. [PMID: 34525989 PMCID: PMC8444384 DOI: 10.1186/s12891-021-04661-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Accepted: 08/26/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND There are different procedures for both, the diagnosis and the therapy of a periprosthetic joint infection (PJI), however, national or international guidelines for a standardised treatment regime are still lacking. The present paper evaluates the use of the predominant treatment protocols for PJI in certified total joint replacement centres (EPZ) in Germany based on an EndoCert questionnaire. MATERIALS AND METHODS The questionnaire was developed in cooperation with the EndoCert Certification Commission to survey the treatment protocols for septic revision arthroplasties in EPZ. Questions targeted the various treatment options including prosthesis preserving procedures (DAIR - Debridement, antibiotics, irrigation, and retention of the prosthesis), one-stage revision, two-stage revision, removal of the endoprosthesis and diagnostic sampling prior to re-implantation. All certified EPZ participated (n = 504) and the results from the current survey in 2020 were compared to data from a previous analysis in 2015. RESULTS The number of centres that performed DAIR up to a maximum of 4 weeks and more than 10 weeks after index surgery decreased since 2015, while the number of centres that provided a one-stage revision as a treatment option increased (hip: + 6.3%; knee: + 6.6%). The majority of the centres (73.2%) indicated a 4-8 week period as the preferred interval between prosthesis removal and re-implantation in two-stage revision in hip as well as knee revisions. Centres with a higher number of revision surgeries (> 200 revisions/year), opted even more often for the 4-8 week period (92.3%). In two-stage revision the use of metal-based spacers with/without reinforcement with antibiotic-containing cement as an interim placeholder was significantly reduced in 2020 compared to 2015. There was also a clear preference for cemented anchoring in two-stage revision arthroplasty in the knee in 2020, whereas the majority of hip replacements was cementless. Additionally, in 2020 the number of samples for microbiological testing during the removal of the infected endoprosthesis increased and 72% of the centres took five or more samples. Overall, the number of EPZ with a standardised protocol for the procedure expanded from 2015 to 2020. CONCLUSION While there was a trend towards standardised therapeutic algorithms for PJI with more uniform choices among the centres in 2020 compared to 2015, the treatment often remains an individual decision. However, since a consistent treatment regime is of vital importance with an expected rise of total numbers of revision arthroplasties, uniform definitions with regard to comparability and standardisation are necessary for the further development of the EndoCert system.
Collapse
Affiliation(s)
- Katrin Osmanski-Zenk
- Orthopädische Klinik und Poliklinik, Universitätsmedizin Rostock, Doberaner Straße 142, 18057, Rostock, Germany.
| | - Annett Klinder
- Orthopädische Klinik und Poliklinik, Universitätsmedizin Rostock, Doberaner Straße 142, 18057, Rostock, Germany
| | - Christina Rimke
- Orthopädische Klinik und Poliklinik, Universitätsmedizin Rostock, Doberaner Straße 142, 18057, Rostock, Germany
| | - Dieter C Wirtz
- Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Bonn, 53127, Bonn, Germany
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke-Universität, 39120, Magdeburg, Germany
| | - Holger Haas
- Zentrum für Orthopädie, Unfallchirurgie und Sportmedizin, Gemeinschaftskrankenhaus Bonn, 53113, Bonn, Germany
| | - Bernd Kladny
- Fachklinik Herzogenaurach, 91074, Herzogenaurach, Germany
| | - Wolfram Mittelmeier
- Orthopädische Klinik und Poliklinik, Universitätsmedizin Rostock, Doberaner Straße 142, 18057, Rostock, Germany
| |
Collapse
|
26
|
Abstract
AIMS The purpose of this study was to compare clinical results, long-term survival, and complication rates of stemless shoulder prosthesis with stemmed anatomical shoulder prostheses for treatment of osteoarthritis and to analyze radiological bone changes around the implants during follow-up. METHODS A total of 161 patients treated with either a stemmed or a stemless shoulder arthroplasty for primary osteoarthritis of the shoulder were evaluated with a mean follow-up of 118 months (102 to 158). The Constant score (CS), the Disabilities of the Arm, Shoulder and Hand (DASH) score, and active range of motion (ROM) were recorded. Radiological analysis for bone adaptations was performed by plain radiographs. A Kaplan-Meier survivorship analysis was calculated and complications were noted. RESULTS The ROM (p < 0.001), CS (p < 0.001), and DASH score (p < 0.001) showed significant improvements after shoulder arthroplasty for both implants. There were no differences between the groups treated with stemmed or stemless shoulder prosthesis with respect to the mean CS (79.2 (35 to 118) vs 74.4 (31 to 99); p = 0.519) and DASH scores (11.4 (8 to 29) vs 13.2 (7 to 23); p = 0.210). The ten-year unadjusted cumulative survival rate was 95.3% for the stemmed anatomical shoulder prosthesis and 91.5% for the stemless shoulder prosthesis and did not differ between the treatment groups (p = 0.251). The radiological evaluation of the humeral components in both groups did not show loosening of the humeral implant. The main reason for revision for each type of arthroplasties were complications related to the glenoid. CONCLUSION The use of anatomical stemless shoulder prosthesis yielded good and reliable results and did not differ from anatomical stemmed shoulder prosthesis over a mean period of ten years. The differences in periprosthetic humeral bone adaptations between both implants have no clinical impact during the follow-up. Cite this article: Bone Joint J 2021;103-B(7):1292-1300.
Collapse
Affiliation(s)
- Nicole Märtens
- Department of Orthopaedic Surgery, Otto von Guericke University Magdeburg, Magdeburg, Germany
| | - Maximilian Heinze
- Department of Orthopaedic Surgery, Asklepios Harzkliniken Fritz-König-Stift Bad Harzburg, Bad Harzburg, Germany
| | - Friedemann Awiszus
- Department of Orthopaedic Surgery, Otto von Guericke University Magdeburg, Magdeburg, Germany
| | - Jessica Bertrand
- Department of Orthopaedic Surgery, Otto von Guericke University Magdeburg, Magdeburg, Germany
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto von Guericke University Magdeburg, Magdeburg, Germany
| | - Alexander Berth
- Department of Orthopaedic Surgery, Otto von Guericke University Magdeburg, Magdeburg, Germany
| |
Collapse
|
27
|
Lazar TA, Edelmann M, Awiszus F, Lohmann CH. Surgical site, gender, and place of residence influence the time to resume driving after total joint arthroplasty. Arch Physiother 2021; 11:16. [PMID: 34183073 PMCID: PMC8240401 DOI: 10.1186/s40945-021-00111-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 05/26/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND For a large proportion of the population, especially those residing in the countryside, the use of a car for daily activities is indispensable. Following a TKA or THA procedure, the overseeing physician will usually recommend refraining from driving, sometimes up to 12 weeks after surgery with a major social and economical impact on patient's life. OBJECTIVE Considering the legal stipulations in Germany regarding fitness to drive a motor vehicle, the aim of this study is to determine the time point when patients after total knee arthroplasty (TKA) or total hip arthroplasty (THA) take up driving again postoperatively. Further, we assessed the replaced joint, side, gender, place of residence and physician's recommendations influencing the patient in making the decision to start driving again. METHODS 92 eligible participants, contained within the frame of a prospective experimental observational study, were contacted via telephone 12 weeks after surgery and interviewed using a structured questionnaire. The answers were statistically analysed using SPSS® Version 26 for Windows. RESULTS Male participants resumed driving between the 6th and 7th week post-surgery, female participants resumed driving between the 8th and 9th week post-surgery. For 58.6% of patients the reason for the first post-operative use of a vehicle was medical: the journey to physical therapy or to a doctor's appointment. There were statistically significant differences regarding operated side, gender and place of residence. TKA impaired patients the most. Patients recovering from a TKA drove considerably later. Patients recovering from a right sided TKA had an increased risk (9 times) not to become an "early driver". Female patients who underwent TKA had an increased risk by a factor of 21 of becoming a "late driver". In the ageing population, surgeons, physical therapists and rehabilitation professionals need to consider new approaches in providing options for patients' mobility. Interestingly, there is a different need for early use of own vehicle in rural regions whereas in cities patients start driving later. There are clear differences between gender and surgical site. CONCLUSIONS The rehabilitation following a right sided TKA proved a challenge with regard to the reuptake of driving. This should be taken into account when planning the course of therapy for patients who are driving regulary. Female patients could benefit from special training. TRIAL REGISTRATION retrospectively registered, DRKS00018693 https://www.drks.de/drks_web/navigate.do?navigationId=trial . HTML&TRIAL_ID=DRKS00018693.
Collapse
Affiliation(s)
- Tiberiu-Adrian Lazar
- Department of Orthopedic Rehabilitation, Celenus Fachklinik Teufelsbad, 18 Michaelstein Strasse, 38889, Blankenburg, Germany. .,Department of Orthopedic Surgery, Otto-von-Guericke University, 44 Leipziger Strasse, 39120, Magdeburg, Germany.
| | - Martin Edelmann
- Department of Orthopedic Rehabilitation, Celenus Fachklinik Teufelsbad, 18 Michaelstein Strasse, 38889, Blankenburg, Germany
| | - Friedemann Awiszus
- Department of Orthopedic Surgery, Otto-von-Guericke University, 44 Leipziger Strasse, 39120, Magdeburg, Germany
| | - Christoph H Lohmann
- Department of Orthopedic Surgery, Otto-von-Guericke University, 44 Leipziger Strasse, 39120, Magdeburg, Germany
| |
Collapse
|
28
|
Meyer F, Dittmann A, Kornak U, Herbster M, Pap T, Lohmann CH, Bertrand J. Chondrocytes From Osteoarthritic and Chondrocalcinosis Cartilage Represent Different Phenotypes. Front Cell Dev Biol 2021; 9:622287. [PMID: 33981699 PMCID: PMC8107373 DOI: 10.3389/fcell.2021.622287] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Accepted: 03/02/2021] [Indexed: 11/13/2022] Open
Abstract
Basic calcium phosphate (BCP)-based calcification of cartilage is a common finding during osteoarthritis (OA) and is directly linked to the severity of the disease and hypertrophic differentiation of chondrocytes. Chondrocalcinosis (CC) is associated with calcium pyrophosphate dihydrate (CPPD) deposition disease in the joint inducing OA-like symptoms. There is only little knowledge about the effect of CPPD crystals on chondrocytes and the signaling pathways involved in their generation. The aim of this study was to investigate the chondrocyte phenotype in CC cartilage and the effect of CPPD crystals on chondrocytes. Cartilage samples of patients with CC, patients with severe OA, and healthy donors were included in this study. The presence of CC was evaluated using standard X-ray pictures, as well as von Kossa staining of cartilage sections. OA severity was evaluated using the Chambers Score on cartilage sections, as well as the radiological Kellgren–Lawrence Score. Patients with radiologically detectable CC presented calcification mainly on the cartilage surface, whereas OA patients showed calcification mainly in the pericellular matrix of hypertrophic chondrocytes. OA cartilage exhibited increased levels of collagen X and matrix metalloproteinase 13 (MMP13) compared with CC and healthy cartilage. This observation was confirmed by qRT-PCR using cartilage samples. No relevant influence of CPPD crystals on hypertrophic marker genes was observed in vitro, whereas BCP crystals significantly induced hypertrophic differentiation of chondrocytes. Interestingly, we observed an increased expression of p16 and p21 in cartilage samples of CC patients compared with OA patients and healthy controls, indicating cellular senescence. To investigate whether CPPD crystals were sufficient to induce senescence, we incubated chondrocytes with BCP and CPPD crystals and quantified senescence using β-gal staining. No significant difference was observed for the staining, but an increase of p16 expression was observed after 10 days of culture. Primary chondrocytes from CC patients produced CPPD crystals in culture. This phenotype was stabilized by mitomycin C-induced senescence. Healthy and OA chondrocytes did not exhibit this phenotype. BCP and CPPD crystals seem to be associated with two different chondrocyte phenotypes. Whereas BCP deposition is associated with chondrocyte hypertrophy, CPPD deposition is associated with cellular senescence.
Collapse
Affiliation(s)
- Franziska Meyer
- Department of Orthopaedic Surgery, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| | - Annalena Dittmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| | - Uwe Kornak
- Institut für Humangenetik, Universitätsmedizin Göttingen, Göttingen, Germany
| | - Maria Herbster
- Department of Orthopaedic Surgery, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| | - Thomas Pap
- Institute of Experimental Musculoskeletal Medicine, University Hospital Muenster, Münster, Germany
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| | - Jessica Bertrand
- Department of Orthopaedic Surgery, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| |
Collapse
|
29
|
Grosser OS, Klutzny M, Wissel H, Kupitz D, Finger M, Schenke S, Wuestemann J, Lohmann CH, Hoeschen C, Pech M, Staerke C, Kreissl MC. Quantitative imaging of bone remodeling in patients with a unicompartmental joint unloading knee implant (ATLAS Knee System)-effect of metal artifacts on a SPECT-CT-based quantification. EJNMMI Phys 2021; 8:15. [PMID: 33595735 PMCID: PMC7889783 DOI: 10.1186/s40658-021-00360-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2020] [Accepted: 01/28/2021] [Indexed: 12/23/2022] Open
Abstract
Background SPECT-CT using radiolabeled phosphonates is considered a standard for assessing bone metabolism (e.g., in patients with osteoarthritis of knee joints). However, SPECT can be influenced by metal artifacts in CT caused by endoprostheses affecting attenuation correction. The current study examined the effects of metal artifacts in CT of a specific endoprosthesis design on quantitative hybrid SPECT-CT imaging. The implant was positioned inside a phantom homogenously filled with activity (955 MBq 99mTc). CT imaging was performed for different X-ray tube currents (I = 10, 40, 125 mA) and table pitches (p = 0.562 and 1.375). X-ray tube voltage (U = 120 kVp) and primary collimation (16 × 0.625 mm) were kept constant for all scans. The CT reconstruction was performed with five different reconstruction kernels (slice thickness, 1.25 mm and 3.75 mm, each 512 × 512 matrix). Effects from metal artifacts were analyzed for different CT scans and reconstruction protocols. ROI analysis of CT and SPECT data was performed for two slice positions/volumes representing the typical locations for target structures relative to the prosthesis (e.g., femur and tibia). A reference region (homogenous activity concentration without influence from metal artifacts) was analyzed for comparison. Results Significant effects caused by CT metal artifacts on attenuation-corrected SPECT were observed for the different slice positions, reconstructed slice thicknesses of CT data, and pitch and CT-reconstruction kernels used (all, p < 0.0001). Based on the optimization, a set of three protocols was identified minimizing the effect of CT metal artifacts on SPECT data. Regarding the reference region, the activity concentration in the anatomically correlated volume was underestimated by 8.9–10.1%. A slight inhomogeneity of the reconstructed activity concentration was detected inside the regions with a median up to 0.81% (p < 0.0001). Using an X-ray tube current of 40 mA showed the best result, balancing quantification and CT exposure. Conclusion The results of this study demonstrate the need for the evaluation of SPECT-CT protocols in prosthesis imaging. Phantom experiments demonstrated the possibility for quantitative SPECT-CT of bone turnover in a specific prosthesis design. Meanwhile, a systematic bias caused by metal implants on quantitative SPECT data has to be considered. Supplementary Information The online version contains supplementary material available at 10.1186/s40658-021-00360-z.
Collapse
Affiliation(s)
- Oliver S Grosser
- Department of Radiology and Nuclear Medicine, University Hospital Magdeburg and Medical Faculty of Otto-von-Guericke University, Leipziger Strasse 44, 39120, Magdeburg, Germany. .,Research Campus STIMULATE, Otto-von-Guericke University, Magdeburg, Germany.
| | - Marcus Klutzny
- Department of Orthopaedic Surgery, University Hospital Magdeburg and Medical Faculty of Otto-von-Guericke University, Magdeburg, Germany
| | - Heiko Wissel
- Department of Radiology and Nuclear Medicine, University Hospital Magdeburg and Medical Faculty of Otto-von-Guericke University, Leipziger Strasse 44, 39120, Magdeburg, Germany
| | - Dennis Kupitz
- Department of Radiology and Nuclear Medicine, University Hospital Magdeburg and Medical Faculty of Otto-von-Guericke University, Leipziger Strasse 44, 39120, Magdeburg, Germany
| | - Michael Finger
- Department of Radiology and Nuclear Medicine, University Hospital Magdeburg and Medical Faculty of Otto-von-Guericke University, Leipziger Strasse 44, 39120, Magdeburg, Germany
| | - Simone Schenke
- Department of Radiology and Nuclear Medicine, University Hospital Magdeburg and Medical Faculty of Otto-von-Guericke University, Leipziger Strasse 44, 39120, Magdeburg, Germany
| | - Jan Wuestemann
- Department of Radiology and Nuclear Medicine, University Hospital Magdeburg and Medical Faculty of Otto-von-Guericke University, Leipziger Strasse 44, 39120, Magdeburg, Germany
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, University Hospital Magdeburg and Medical Faculty of Otto-von-Guericke University, Magdeburg, Germany
| | - Christoph Hoeschen
- Chair of Medical Systems Technology, Institute of Medical Engineering, Faculty of Electrical Engineering and Information Technology, Otto-von-Guericke University, Magdeburg, Germany
| | - Maciej Pech
- Department of Radiology and Nuclear Medicine, University Hospital Magdeburg and Medical Faculty of Otto-von-Guericke University, Leipziger Strasse 44, 39120, Magdeburg, Germany.,Research Campus STIMULATE, Otto-von-Guericke University, Magdeburg, Germany
| | - Christian Staerke
- Department of Orthopaedic Surgery, University Hospital Magdeburg and Medical Faculty of Otto-von-Guericke University, Magdeburg, Germany
| | - Michael C Kreissl
- Department of Radiology and Nuclear Medicine, University Hospital Magdeburg and Medical Faculty of Otto-von-Guericke University, Leipziger Strasse 44, 39120, Magdeburg, Germany.,Research Campus STIMULATE, Otto-von-Guericke University, Magdeburg, Germany
| |
Collapse
|
30
|
Bollmann M, Pinno K, Ehnold LI, Märtens N, Märtson A, Pap T, Stärke C, Lohmann CH, Bertrand J. MMP-9 mediated Syndecan-4 shedding correlates with osteoarthritis severity. Osteoarthritis Cartilage 2021; 29:280-289. [PMID: 33246160 DOI: 10.1016/j.joca.2020.10.009] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 09/25/2020] [Accepted: 10/13/2020] [Indexed: 02/02/2023]
Abstract
OBJECTIVE Osteoarthritis (OA) is a degenerative joint disease inducing the degradation of the articular cartilage. Syndecan-4 (Sdc4) is a heparan sulfate proteoglycan, expressed under inflammatory conditions and by chondrocytes during OA. Little is known about Sdc4 shedding and its regulation in OA. Therefore, we investigated the regulation of Sdc4 shedding and underlying shedding mechanisms under OA conditions. DESIGN Articular cartilage, serum, synovial fluid and synovial membrane from OA patients with different radiological severity were analyzed. ELISA, RT-qPCR and IHC for Sdc4, MMP-2 and -9 were performed. MMP inhibitors and siRNA were evaluated for their effect on Sdc4 shedding by ELISA and on IL-1 signaling by western blot (pERK/ERK). RESULTS Shed Sdc4 was increased in synovial fluid of OA patients, but not in the serum and is a good predictor (AUC = 0.72) for OA severity with a sensitivity of 67.5% and specificity 65.2%. MMP-9, but not MMP-2, was increased in cartilage and synovial membrane at mRNA levels and in the synovial fluid at protein levels. Shed Sdc4 correlated with the amount of MMP-9 in synovial fluid. Further, the inhibition and knock-down of MMP-9 decreased the amount of shed Sdc4 in vitro. Increased Sdc4 shedding resulted in less phosphorylation of ERK upon IL-1β stimulation. CONCLUSION Shed Sdc4 might be a good prognostic biomarker for OA mediated cartilage degradation. MMP-9 seems to be the relevant sheddase for Sdc4 under OA conditions, desensitizing chondrocytes towards IL-1 signaling.
Collapse
Affiliation(s)
- M Bollmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - K Pinno
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - L I Ehnold
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - N Märtens
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - A Märtson
- Department of Traumatology and Orthopedics, University of Tartu, Tartu University Hospital, Tartu, Estonia
| | - T Pap
- Institute of Musculoskeletal Medicine, University Hospital Münster, Münster, Germany
| | - C Stärke
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - C H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - J Bertrand
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany.
| |
Collapse
|
31
|
Vogel M, Meyer F, Frommer J, Walter M, Lohmann CH, Croner R. Unwillingly traumatizing: is there a psycho-traumatologic pathway from general surgery to postoperative maladaptation? Scand J Pain 2020; 21:238-246. [PMID: 34387954 DOI: 10.1515/sjpain-2020-0081] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2020] [Accepted: 10/04/2020] [Indexed: 12/17/2022]
Abstract
BACKGROUND Surgery may possibly be undermined by psychologic, psychiatric and psychosomatic problems, as long as these problems interfere with a patient's capacity to cope with surgery adaptively. Recent studies have shown that interpersonal trauma, e.g. abuse or neglect, and its correlates are involved in the adaptation to surgery. This observation is heuristically coherent, given the respective traumatization is an interpersonal event occurring in a relationship. Notably, surgery inevitably leads to the violation of physical boundaries within a doctor-patient relationship. Based on the principles of psycho-traumatologic thinking, such a constellation is deemed qualified to activate posttraumatic symptoms in the traumatized. METHOD The present topical review summarizes the respective findings which point to a subgroup of patients undergoing surgery, in whom difficulty bearing tension and confiding in others may cause adaptive problems relevant to surgery. Although this theorizing is empirically substantiated primarily with respect to total knee arthroplasty (TKA), a pubmed-research reveals psychopathologic distress to occur prior to surgery beyond TKA. Likewise, posttraumatic distress occurs in large numbers in the context of several operations, including cardiac, cancer and hernia surgery. CONCLUSION Aspects of psychological trauma may be linked to the outcomes of general surgery, as well, e.g. biliary, hernia or appendix surgery. The mechanisms possibly involved in this process are outlined in terms of a hierarchical organization of specific anxiety and negative affect as well as in terms of psychodynamics which imply the unconscious action of psychologic defenses at their core. IMPLICATIONS Not least, we encourage the screening for trauma and its correlates including defenses prior to general surgery in order to identify surgical candidates at risk of, e.g. chronic postoperative pain, before the operation.
Collapse
Affiliation(s)
- Matthias Vogel
- Department of Psychosomatic Medicine and Psychotherapy, Otto-von-Guericke University, Magdeburg, Germany
| | - Frank Meyer
- Department of Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Jörg Frommer
- Department of Psychosomatic Medicine and Psychotherapy, Otto-von-Guericke University, Magdeburg, Germany
| | - Martin Walter
- Department of Psychiatry and Psychotherapy, University Hospital Jena Friedrich Schiller University, Jena, Germany
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Roland Croner
- Department of Surgery, Otto-von-Guericke University, Magdeburg, Germany
| |
Collapse
|
32
|
Herbster M, Döring J, Nohava J, Lohmann CH, Halle T, Bertrand J. Retrieval study of commercially available knee implant coatings TiN, TiNbN and ZrN on TiAl6V4 and CoCr28Mo6. J Mech Behav Biomed Mater 2020; 112:104034. [PMID: 32871541 DOI: 10.1016/j.jmbbm.2020.104034] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Revised: 07/21/2020] [Accepted: 08/10/2020] [Indexed: 12/13/2022]
Abstract
BACKGROUND Coated implant components for total knee arthroplasties are primarily used for metal-sensitive patients and are offered by different manufacturers. However, there is only little knowledge with respect to their coating design and supposed superior tribological performance. Our aim was to compare retrieved coated implants by identifying present damages, critical factors influencing the coating durability and their correlation to the clinical performance. MATERIALS AND METHODS 28 retrieved knee endoprostheses from nine different manufacturers were analyzed for potential surface defects as well as the coating strategy for each manufacturer. The coating designs were investigated on preserved regions with regard to substrate and coating material, layer thickness and roughness using scanning electron microscopy and confocal microscopy. Furthermore, the mechanical properties and adhesive strength of the layer were evaluated by nanoindentation and scratch testing. The friction performance of the coatings against ultra-high molecular weight polyethylene (UHMWPE) was investigated in a tribological test. In addition, clinical data were collected and evaluated for all patients. RESULTS Our cohort of 28 retrieved knee endoprostheses exhibited different damage patterns in the articulating area with an incidence of 79% for discoloration and 21% for coating delamination. All coatings presented droplets, macropores and pinholes in preserved areas, which can be attributed to the coating and post-polishing processes. Interestingly, the adhesive strength was significantly increased by 60.4% for titanium nitride coatings on TiAl6V4 alloy in comparison to CoCr28Mo6 substrates. The friction behavior of titanium nitride coatings against UHMWPE is similar to uncoated CoCr28Mo6 alloy and lowest for the ZrN multi-layer coating with a reduction of 14%. DISCUSSION This study shows that manufacturing related coating deposition defects can cause wear due to adhesive failure and corrosion underneath the coating layers. Adhesive strength was identified as a critical factor for coating durability. Minor adhesive strength was present on CoCr28Mo6 cast alloy in comparison to good adhesion of Ti-based coatings on TiAl6V4 wrought alloy. Based on our findings, this is consistent to higher prevalence rates of CoCr28Mo6/TiNbN coatings for gross delamination and pitting damage with increasing implantation time.
Collapse
Affiliation(s)
- Maria Herbster
- Institute of Materials and Joining Technology, Otto-von-Guericke University, Magdeburg, Germany.
| | - Joachim Döring
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | | | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Thorsten Halle
- Institute of Materials and Joining Technology, Otto-von-Guericke University, Magdeburg, Germany
| | - Jessica Bertrand
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| |
Collapse
|
33
|
Abstract
Aims This study aimed to examine the effects of tumour necrosis factor-alpha (TNF-α) on osteoblasts in metal wear-induced bone loss. Methods TNF-α immunoexpression was examined in periprosthetic tissues of patients with failed metal-on-metal hip arthroplasties and also in myeloid MM6 cells after treatment with cobalt ions. Viability and function of human osteoblast-like SaOs-2 cells treated with recombinant TNF-α were studied by immunofluorescence, terminal deoxynucleotidyl transferase-mediated dUTP nick end labelling (TUNEL) assay, western blotting, and enzyme-linked immunosorbent assay (ELISA). Results Macrophages, lymphocytes, and endothelial cells displayed strong TNF-α immunoexpression in periprosthetic tissues containing metal wear debris. Colocalization of TNF-α with the macrophage marker CD68 and the pan-T cell marker CD3 confirmed TNF-α expression in these cells. Cobalt-treated MM6 cells secreted more TNF-α than control cells, reflecting the role of metal wear products in activating the TNF-α pathway in the myeloid cells. While TNF-α did not alter the immunoexpression of the TNF-receptor 1 (TNF-R1) in SaOs-2 cells, it increased the release of the soluble TNF-receptor 1 (sTNF-R1). There was also evidence for TNF-α-induced apoptosis. TNF-α further elicited the expression of the endoplasmic reticulum stress markers inositol-requiring enzyme (IRE)-1α, binding-immunoglobulin protein (BiP), and endoplasmic oxidoreductin1 (Ero1)-Lα. In addition, TNF-α decreased pro-collagen I α 1 secretion without diminishing its synthesis. TNF-α also induced an inflammatory response in SaOs-2 cells, as evidenced by the release of reactive oxygen and nitrogen species and the proinflammatory cytokine vascular endothelial growth factor. Conclusion The results suggest a novel osteoblastic mechanism, which could be mediated by TNF-α and may be involved in metal wear debris-induced periprosthetic bone loss. Cite this article: Bone Joint Res 2020;9(11):827–839.
Collapse
Affiliation(s)
- Rita Hameister
- Department of Anatomy, Yong Loo Lin School of Medicine, National University of Singapore, Singapore
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto von Guericke University Magdeburg, Magdeburg, Germany
| | - S Thameem Dheen
- Department of Anatomy, Yong Loo Lin School of Medicine, National University of Singapore, Singapore
| | | | - Charanjit Kaur
- Department of Anatomy, Yong Loo Lin School of Medicine, National University of Singapore, Singapore
| |
Collapse
|
34
|
Rimke C, Enz A, Bail HJ, Heppt P, Kladny B, von Lewinski G, Lohmann CH, Osmanski-Zenk K, Haas H, Mittelmeier W. Evaluation of the standard procedure for the treatment of periprosthetic joint infections (PJI) in Germany - results of a survey within the EndoCert initiative. BMC Musculoskelet Disord 2020; 21:694. [PMID: 33076900 PMCID: PMC7574524 DOI: 10.1186/s12891-020-03670-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Accepted: 09/24/2020] [Indexed: 02/07/2023] Open
Abstract
BACKGROUND The periprosthetic joint infection (PJI) is a severe complication in the field of arthroplasty. Despite the rising number of primary joint replacements, no unified therapeutic standard has been established for the treatment of PJI yet. METHODS A survey on the principles of treatment of PJI in Germany was conducted. A total of 515 EndoProthetikZentren (EPZ) were included, resulting in a response rate of 100%. RESULTS For early infections 97.6% of the centers use prosthesis-preserving procedures (DAIR). A one-stage exchange was implemented by less than 50% of the centers. If implemented, this treatment entails a prior selection of patients for a successful treatment. The two-stage exchange is performed in all centers, and most centers proceed with the implantation of a cemented spacer between stages. 75% of the centers proceed with a center-based concept for the treatment of PJI. CONCLUSION The aim of a uniform PJI standard at the centers has not yet been fully achieved. Further improvements within the certification were initiated. The most relevant treatment options in Germany are displayed. The two-stage revision with a cemented spacer is the most widely implemented treatment. This exposition of principles could help for the further development of standardized treatment guidelines and definitions.
Collapse
Affiliation(s)
- Christina Rimke
- Orthopädische Klinik und Poliklinik, Universitätsmedizin Rostock, Doberaner Straße 142, 18059, Rostock, Germany
| | - Andreas Enz
- Orthopädische Klinik und Poliklinik, Universitätsmedizin Rostock, Doberaner Straße 142, 18059, Rostock, Germany.
| | - Hermann Josef Bail
- Klinik für Orthopädie und Unfallchirurgie, Klinikum Nürnberg Süd, Universitätsklinik der Paracelsus Medizinischen Privatuniversität Nürnberg, Breslauer Straße 201, 90471, Nuremberg, Germany
| | - Peter Heppt
- OCE Orthopädie Centrum Erlangen, Nägelsbachstraße 49A, 91052, Erlangen, Germany
| | - Bernd Kladny
- M&I Fachklinik Herzogenaurach, In der Reuth 1, 91074, Herzogenaurach, Germany
| | - Gabriela von Lewinski
- Klinik für Unfallchirurgie, Orthopädie und Plastische Chirurgie, Universitätsmedizin Göttingen, Robert-Koch-Straße 40, 37075, Goettingen, Germany
| | - Christoph H Lohmann
- Orthopädische Universitätsklinik, Otto-von-Guericke Universität Magdeburg, Leipziger Str. 44, 39120, Magdeburg, Germany
| | - Katrin Osmanski-Zenk
- Orthopädische Klinik und Poliklinik, Universitätsmedizin Rostock, Doberaner Straße 142, 18059, Rostock, Germany
| | - Holger Haas
- Allgemeine Orthopädie, Unfallchirurgie und Sportmedizin, Gemeinschaftskrankenhaus St Elisabeth St Petrus St Johannes gGmbH, Haus St. Petrus / Bonner Talweg 4-6, 53113, Bonn, Germany
| | - Wolfram Mittelmeier
- Orthopädische Klinik und Poliklinik, Universitätsmedizin Rostock, Doberaner Straße 142, 18059, Rostock, Germany
| |
Collapse
|
35
|
Amrhein J, Drynda S, Schlatt L, Karst U, Lohmann CH, Ciarimboli G, Bertrand J. Tofacitinib and Baricitinib Are Taken up by Different Uptake Mechanisms Determining the Efficacy of Both Drugs in RA. Int J Mol Sci 2020; 21:ijms21186632. [PMID: 32927842 PMCID: PMC7556031 DOI: 10.3390/ijms21186632] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Revised: 09/03/2020] [Accepted: 09/09/2020] [Indexed: 12/29/2022] Open
Abstract
Background: Rheumatoid arthritis (RA) is a systemic autoimmune disease in which synovial fibroblasts (SF) play a key role. Baricitinib and Tofacitinib both act intracellularly, blocking the ATP-binding side of JAK proteins and thereby the downstream signalling pathway via STAT-3. Therefore, we investigated the role of organic cation transporters (OCTs) in Baricitinib and Tofacitinib cellular transport. Methods: OCT expression was analysed in SF isolated from RA and osteoarthritis (OA) patients, as well as peripheral blood mononuclear cells. The interaction of Baricitinib and Tofacitinib with OCTs was investigated using quenching experiments. The intracellular accumulation of both drugs was quantified using LC/MS. Target inhibition for both drugs was tested using Western blot for phosphorylated JAK1 and STAT3 upon stimulation with IL-6. Results: MATE-1 expression increased in OASF compared to RASF. The other OCTs were not differentially expressed. The transport of Baricitinib was not OCT dependent. Tofacitinib; however, was exported from RASF in a MATE-1 dependent way. Tofacitinib and Baricitinib showed comparable inhibition of downstream signalling pathways. Conclusion: We observed different cellular uptake strategies for Baricitinib and Tofacitinib. Tofacitinib was exported out of healthy cells due to the increased expression of MATE1. This might make Tofacitinib the favourable drug.
Collapse
Affiliation(s)
- Jan Amrhein
- Experimental Nephrology, Department of Internal Medicine D, University Hospital Münster, 48149 Münster, Germany; (J.A.); (G.C.)
| | - Susanne Drynda
- Department of Orthopedic Surgery, Otto-von-Guericke University, 39120 Magdeburg, Germany; (S.D.); (C.H.L.)
| | - Lukas Schlatt
- Institute of Inorganic and Analytical Chemistry, University of Münster, 48149 Münster, Germany; (L.S.); (U.K.)
| | - Uwe Karst
- Institute of Inorganic and Analytical Chemistry, University of Münster, 48149 Münster, Germany; (L.S.); (U.K.)
| | - Christoph H. Lohmann
- Department of Orthopedic Surgery, Otto-von-Guericke University, 39120 Magdeburg, Germany; (S.D.); (C.H.L.)
| | - Giuliano Ciarimboli
- Experimental Nephrology, Department of Internal Medicine D, University Hospital Münster, 48149 Münster, Germany; (J.A.); (G.C.)
| | - Jessica Bertrand
- Department of Orthopedic Surgery, Otto-von-Guericke University, 39120 Magdeburg, Germany; (S.D.); (C.H.L.)
- Correspondence: ; Tel.: +49-391-67-15804
| |
Collapse
|
36
|
Bertrand J, Kräft T, Gronau T, Sherwood J, Rutsch F, Lioté F, Dell'Accio F, Lohmann CH, Bollmann M, Held A, Pap T. BCP crystals promote chondrocyte hypertrophic differentiation in OA cartilage by sequestering Wnt3a. Ann Rheum Dis 2020; 79:975-984. [PMID: 32371389 DOI: 10.1136/annrheumdis-2019-216648] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2019] [Revised: 04/15/2020] [Accepted: 04/18/2020] [Indexed: 12/14/2022]
Abstract
OBJECTIVE Calcification of cartilage with basic calcium phosphate (BCP) crystals is a common phenomenon during osteoarthritis (OA). It is directly linked to the severity of the disease and known to be associated to hypertrophic differentiation of chondrocytes. One morphogen regulating hypertrophic chondrocyte differentiation is Wnt3a. METHODS Calcification and sulfation of extracellular matrix of the cartilage was analysed over a time course from 6 to 22 weeks in mice and different OA grades of human cartilage. Wnt3a and ß-catenin was stained in human and murine cartilage. Expression of sulfation modulating enzymes (HS2St1, HS6St1) was analysed using quantitative reverse transcription PCR (RT-PCR). The influence of BCP crystals on the chondrocyte phenotype was investigated using quantitative RT-PCR for the marker genes Axin2, Sox9, Col2, MMP13, ColX and Aggrecan. Using western blot for β-catenin and pLRP6 we investigated the activation of Wnt signalling. The binding capacity of BCP for Wnt3a was analysed using immunohistochemical staining and western blot. RESULTS Here, we report that pericellular matrix sulfation is increased in human and murine OA. Wnt3a co-localised with heparan sulfate proteoglycans in the pericellular matrix of chondrocytes in OA cartilage, in which canonical Wnt signalling was activated. In vitro, BCP crystals physically bound to Wnt3a. Interestingly, BCP crystals were sufficient to induce canonical Wnt signalling as assessed by phosphorylation of LRP6 and stabilisation of β-catenin, and to induce a hypertrophic shift of the chondrocyte phenotype. CONCLUSION Consequently, our data identify BCP crystals as a concentrating factor for Wnt3a in the pericellular matrix and an inducer of chondrocyte hypertrophy.
Collapse
Affiliation(s)
- Jessica Bertrand
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Tabea Kräft
- Division of Mol Medicine of Musculoskeletal Tissue, University Munster, Munster, Germany
| | - Tobias Gronau
- Division of Mol Medicine of Musculoskeletal Tissue, University Munster, Munster, Germany
| | - Joanna Sherwood
- Division of Mol Medicine of Musculoskeletal Tissue, University Munster, Munster, Germany
| | - Frank Rutsch
- Department of General Pediatrics, University Munster, Munster, Germany
| | - Frédéric Lioté
- INSERM UMR-1132, Université Paris Diderot, Paris, France
| | - Francesco Dell'Accio
- William Harvey Research Institute, Centre for Experimental Medicine and Rheumatology, London, UK
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Miriam Bollmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Annelena Held
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Thomas Pap
- Division of Mol Medicine of Musculoskeletal Tissue, University Munster, Munster, Germany
| |
Collapse
|
37
|
Lotz EM, Lohmann CH, Boyan BD, Schwartz Z. Bisphosphonates inhibit surface-mediated osteogenesis. J Biomed Mater Res A 2020; 108:1774-1786. [PMID: 32276287 DOI: 10.1002/jbm.a.36944] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2018] [Revised: 03/09/2020] [Accepted: 03/11/2020] [Indexed: 12/17/2022]
Abstract
Bisphosphonates (BPs) target osteoclasts, slowing bone resorption thus providing rationale to support osseointegration. However, BPs may negatively affect osteoblasts, impairing peri-implant bone formation. The goal of this study was to assess the effects BPs have on surface-mediated osteogenesis of osteoblasts. MG63 cells were cultured on 15-mm grade 2 titanium disks: smooth, hydrophobic-microrough, or hydrophilic-microrough (Institut Straumann AG, Basel, Switzerland). Tissue culture polystyrene (TCPS) was used as a control. At confluence, cells were treated with 0, 10-8 , 10-7 , and 10-6 M of alendronate, zoledronate, or ibandronate for 24 hr. Sprague Dawley rats were also treated with 1 μg/kg/day ibandronate or phosphate-buffered saline control for 5 weeks. Calvarial osteoblasts (rat osteoblasts [rOBs]) were isolated, characterized, and cultured on surfaces. Osteogenic markers in the media were quantified using ELISAs. BP treatment reduced osteocalcin, osteoprotegerin, osteopontin, bone morphogenetic protein-2, prostaglandin E2 , transforming growth factor β1, interleukin 10, and vascular endothelial growth factor in MG63 cells. The effect was more robust on rough surfaces, and higher concentrations of BPs stunted production to TCPS/PT levels. Ibandronate conditioned rOBs produced less osteogenic markers similar to direct BP treatment. These results suggest that BP exposure jeopardizes the pro-osteogenic response osteoblasts have to microstructured surfaces. Their effects persist in vivo and negatively condition osteoblast response in vitro. Clinically, BPs could compromise osseointegration.
Collapse
Affiliation(s)
- Ethan M Lotz
- Department of Biomedical Engineering, College of Engineering, Virginia Commonwealth University, Richmond, Virginia, USA
| | - Christoph H Lohmann
- Department of Orthopaedics, Otto-von-Guericke-University, Magdeburg, Germany
| | - Barbara D Boyan
- Department of Biomedical Engineering, College of Engineering, Virginia Commonwealth University, Richmond, Virginia, USA
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA
| | - Zvi Schwartz
- Department of Biomedical Engineering, College of Engineering, Virginia Commonwealth University, Richmond, Virginia, USA
- Department of Periodontics, University of Texas Health Science Center at San Antonio, San Antonio, Texas, USA
| |
Collapse
|
38
|
Koks S, Wood DJ, Reimann E, Awiszus F, Lohmann CH, Bertrand J, Prans E, Maasalu K, Märtson A. The Genetic Variations Associated With Time to Aseptic Loosening After Total Joint Arthroplasty. J Arthroplasty 2020; 35:981-988. [PMID: 31791832 DOI: 10.1016/j.arth.2019.11.004] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/17/2019] [Revised: 10/07/2019] [Accepted: 11/04/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Total joint arthroplasty (TJA) is one of the most frequent surgical procedures performed in modern hospitals, and aseptic loosening is the most common indication for revision surgeries. We conducted a systemic exploration of potential genetic determinants for early aseptic loosening. METHODS Data from 423 patients undergoing TJA were collected and analyzed. Three analytical groups were formed based on joint arthroplasty status. Group 1 were TJA patients without symptoms of aseptic loosening of at least 1 year, group 2 were patients with primary TJA, and group 3 were patients receiving revision surgery because of aseptic loosening. Genome-wide genotyping comparing genotype frequencies between patients with and without aseptic loosening (group 3 vs groups 1 and 2) was conducted. A case-control association analysis and linear modeling were applied to identify the impact of the identified genes on implant survival with time to the revision as an outcome measure. RESULTS We identified 52 single-nucleotide polymorphisms (SNPs) with a genome-wide suggestive P value less than 10-5 to be associated with the implant loosening. The most remarkable odds ratios (OR) were found with the variations in the IFIT2/IFIT3 (OR, 21.6), CERK (OR, 12.6), and PAPPA (OR, 14.0) genes. Variations in the genotypes of 4 SNPs-rs115871127, rs16823835, rs13275667, and rs2514486-predicted variability in the time to aseptic loosening. The time to aseptic loosening varied from 8 to 16 years depending on the genotype, indicating a substantial effect of genetic variance. CONCLUSION Development of the aseptic loosening is associated with several genetic variations and we identified at least 4 SNPs with a significant effect on the time for loosening. These data could help to develop a personalized approach for TJA and loosening management.
Collapse
Affiliation(s)
- Sulev Koks
- Centre for Molecular Medicine and Innovative Therapeutics, Murdoch University, Murdoch, WA, Australia; The Perron Institute for Neurological and Translational Science, Nedlands, WA, Australia
| | - David J Wood
- Department of Surgery, The University of Western Australia, Nedlands, WA, Australia
| | - Ene Reimann
- Department of Pathophysiology, University of Tartu, Tartu, Estonia
| | - Friedemann Awiszus
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Jessica Bertrand
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Ele Prans
- Department of Pathophysiology, University of Tartu, Tartu, Estonia
| | - Katre Maasalu
- Department of Traumatology and Orthopaedics, University of Tartu, Tartu, Estonia; Clinic of Traumatology and Orthopaedics, Tartu University Hospital, Tartu, Estonia
| | - Aare Märtson
- Department of Traumatology and Orthopaedics, University of Tartu, Tartu, Estonia; Clinic of Traumatology and Orthopaedics, Tartu University Hospital, Tartu, Estonia
| |
Collapse
|
39
|
Vogel M, Frenzel L, Riediger C, Haase M, Frommer J, Lohmann CH, Illiger S. The Pain Paradox of Borderline Personality and Total Knee Arthroplasty (TKA): Recruiting Borderline Personality Organization to Predict the One-Year Postoperative Outcome. J Pain Res 2020; 13:49-55. [PMID: 32021394 PMCID: PMC6959492 DOI: 10.2147/jpr.s226433] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2019] [Accepted: 12/24/2019] [Indexed: 11/23/2022] Open
Abstract
Background TKA is a common treatment for arthropathies of the knee; however, its results are compromised by psychosocial equivalents of pain: prior research suggests persistent pain and dysfunction after TKA not only to be linked to psychological symptoms such as depression or anxiety but also to psychodynamic determinants of borderline personality, namely borderline personality organization. Osteoarthritis (OA) and Rheumatoid arthritis (RA), the main indications for TKA, are themselves linked to personality factors and disorders, e.g. borderline. The present study investigates the influence of borderline personality organization (BPO) on the outcomes of TKA one year postoperatively. Methods We studied 144 patients scheduled for primary TKA before and after the operation using the IPO-16 and the WOMAC for the assessment of knee pain and function. Results Non-parametric correlations were found between primitive defenses and knee-pain, not function. Linear regression showed prediction of knee pain and knee function by the preoperative WOMAC scores (p<0.01), whereas there was additional prediction of knee-pain by gender (p=0.03) and primitive defenses (p=0.04). Discussion The results suggest a psychodynamic mechanism of maladaptation after TKA apparently representing the bodily manifestations of fundamental psychic defenses.
Collapse
Affiliation(s)
- Matthias Vogel
- Universitätsklinik für Psychosomatische Medizin und Psychotherapie der Otto-von-Guericke-Universität Magdeburg, Magdeburg 39120, Germany
| | - Lydia Frenzel
- Universitätsklinik für Psychosomatische Medizin und Psychotherapie der Otto-von-Guericke-Universität Magdeburg, Magdeburg 39120, Germany
| | - Christian Riediger
- Universitätsklinik für Orthopädie der Otto-von-Guericke-Universität Magdeburg, Magdeburg 39120, Germany
| | - Matthias Haase
- Universitätsklinik für Psychosomatische Medizin und Psychotherapie der Otto-von-Guericke-Universität Magdeburg, Magdeburg 39120, Germany
| | - Jörg Frommer
- Universitätsklinik für Psychosomatische Medizin und Psychotherapie der Otto-von-Guericke-Universität Magdeburg, Magdeburg 39120, Germany
| | - Christoph H Lohmann
- Universitätsklinik für Orthopädie der Otto-von-Guericke-Universität Magdeburg, Magdeburg 39120, Germany
| | - Sebastian Illiger
- Universitätsklinik für Orthopädie der Otto-von-Guericke-Universität Magdeburg, Magdeburg 39120, Germany
| |
Collapse
|
40
|
Hameister R, Kaur C, Dheen ST, Lohmann CH, Singh G. Reactive oxygen/nitrogen species (ROS/RNS) and oxidative stress in arthroplasty. J Biomed Mater Res B Appl Biomater 2020; 108:2073-2087. [PMID: 31898397 DOI: 10.1002/jbm.b.34546] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2019] [Revised: 11/19/2019] [Accepted: 12/08/2019] [Indexed: 12/16/2022]
Abstract
The interplay between implant design, biomaterial characteristics, and the local microenvironment adjacent to the implant is of utmost importance for implant performance and success of the joint replacement surgery. Reactive oxygen and nitrogen species (ROS/RNS) are among the various factors affecting the host as well as the implant components. Excessive formation of ROS and RNS can lead to oxidative stress, a condition that is known to damage cells and tissues and also to affect signaling pathways. It may further compromise implant longevity by accelerating implant degradation, primarily through activation of inflammatory cells. In addition, wear products of metallic, ceramic, polyethylene, or bone cement origin may also generate oxidative stress themselves. This review outlines the generation of free radicals and oxidative stress in arthroplasty and provides a conceptual framework on its implications for soft tissue remodeling and bone resorption (osteolysis) as well as implant longevity. Key findings derived from cell culture studies, animal models, and patients' samples are presented. Strategies to control oxidative stress by implant design and antioxidants are explored and areas of controversy and challenges are highlighted. Finally, directions for future research are identified. A better understanding of the host-implant interplay and the role of free radicals and oxidative stress will help to evaluate therapeutic approaches and will ultimately improve implant performance in arthroplasty.
Collapse
Affiliation(s)
- Rita Hameister
- Department of Anatomy, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Charanjit Kaur
- Department of Anatomy, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Shaikali Thameem Dheen
- Department of Anatomy, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Gurpal Singh
- Centre for Orthopaedics Pte Ltd, Singapore, Singapore
| |
Collapse
|
41
|
Crackau M, Märtens N, Harnisch K, Berth A, Döring J, Lohmann CH, Halle T, Bertrand J. In vivo corrosion and damages in modular shoulder prostheses. J Biomed Mater Res B Appl Biomater 2019; 108:1764-1778. [PMID: 31763747 DOI: 10.1002/jbm.b.34519] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2019] [Revised: 09/30/2019] [Accepted: 11/04/2019] [Indexed: 11/08/2022]
Abstract
Wear and corrosion at taper junctions of orthopaedic endoprostheses remain of great concern and are associated with adverse clinical reactions. Whereas tribocorrosion of hip tapers was extensively investigated, there is only little knowledge regarding the clinical performance of modular total shoulder prostheses. This retrieval study evaluated 35 modular taper junctions of anatomical shoulder explants using stereomicroscopy, confocal microscopy, as well as optical and scanning electron microscopy to determine the damage modes as well as the effects of taper topography and alloy microstructure. Among all humeral head tapers, 89% exhibited material degradation. Different overlapping wear mechanisms were identified such as plastic deformation, adhesive material transfer, microploughing, and fretting damage. Only CoCrMo cast alloy heads showed a susceptibility to electrochemically dominated fretting in comparison to CoCrMo wrought alloy. Moreover, corundum blasted stem tapers show a significantly increased incidence rate for microploughing. To date, this is the most comprehensive study on the damage types of modular taper junctions of anatomical shoulder arthroplasty proving the existence of fretting even on less weight-bearing implants. This study revealed critical fretting factors, such as the surface finish and the alloy type that are essential for the development of countermeasures that avoid any taper corrosion.
Collapse
Affiliation(s)
- Maria Crackau
- Institute of Materials and Joining Technology, Otto-von-Guericke University, Magdeburg, Germany.,Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Nicole Märtens
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Karsten Harnisch
- Institute of Materials and Joining Technology, Otto-von-Guericke University, Magdeburg, Germany
| | - Alexander Berth
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Joachim Döring
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Thorsten Halle
- Institute of Materials and Joining Technology, Otto-von-Guericke University, Magdeburg, Germany
| | - Jessica Bertrand
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| |
Collapse
|
42
|
Hameister R, Lohmann CH, Dheen ST, Singh G, Kaur C. Bone biology in postnatal Wistar rats following hypoxia-reoxygenation. Histol Histopathol 2019; 35:111-124. [PMID: 31268167 DOI: 10.14670/hh-18-143] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Hypoxia response pathways have a central role in normal and abnormal bone biology but the effect of systemic hypoxia-reoxygenation on bone is not clear. Following hypoxic exposure, aberrant synthesis, folding and trafficking of proteins has been reported to occur, which can result in endoplasmic reticulum (ER) stress and may finally cause cell death. This study aimed to examine the effect of systemic hypoxia-reoxygenation injury on bone biology in postnatal rats. Immunoexpression of HIF-1α and VEGF was upregulated in femurs of newborn Wistar rats in response to systemic hypoxia-reoxygenation. Along with that, increased apoptosis of osteoblast precursors, osteoblasts, osteocytes and endothelial cells was observed in comparison to femurs of control animals by transmission electron microscopy, TUNEL staining and immunoexpression of cleaved caspase-3. The viability of osteoclasts was not affected. After hypoxia-reoxygenation, ER stress was observed in the osteoblasts and osteocytes as indicated by dilatation of the ER and enhanced immunoexpression of the ER stress marker GRP78. Localisation of collagen α1 immunoreaction was widespread in the bone matrix of control femurs but was confined to the osteoblasts and osteocytes in response to hypoxia-reoxygenation. In support of these findings, in vitro work showed reduced viability of osteoblast-like SaOs-2 cells and upregulation of GRP78 protein expression in them by western blotting following exposure to hypoxia. This suggests that systemic hypoxia-reoxygenation may disturb bone biology in postnatal Wistar rats by inducing ER stress and apoptosis in osteoblasts and osteocytes, without affecting the viability of osteoclasts. More in-depth research is needed to confirm causality between ER stress and apoptosis of osteoblasts and osteocytes.
Collapse
Affiliation(s)
- Rita Hameister
- Department of Anatomy, Yong Loo Lin School of Medicine, National University of Singapore, Singapore
| | - Christoph H Lohmann
- Otto-von-Guericke University, Department of Orthopaedic Surgery, Magdeburg, Germany
| | - S Thameem Dheen
- Department of Anatomy, Yong Loo Lin School of Medicine, National University of Singapore, Singapore
| | - Gurpal Singh
- University Orthopaedics, Hand and Reconstructive Microsurgery Cluster, National University Health System, Singapore
| | - Charanjit Kaur
- Department of Anatomy, Yong Loo Lin School of Medicine, National University of Singapore, Singapore.
| |
Collapse
|
43
|
Döring J, Crackau M, Nestler C, Welzel F, Bertrand J, Lohmann CH. Characteristics of different cathodic arc deposition coatings on CoCrMo for biomedical applications. J Mech Behav Biomed Mater 2019; 97:212-221. [PMID: 31129165 DOI: 10.1016/j.jmbbm.2019.04.026] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2018] [Revised: 03/11/2019] [Accepted: 04/13/2019] [Indexed: 01/19/2023]
Abstract
Coatings of endoprostheses are used to improve the tribological performance of arthroplasties. A major challenge for the successful use of these coatings, however, is a stable layer adhesion, a smooth surface, as well as a reduction in droplet formation during the coating process. Explants with commercially available coatings were investigated to assess surface/layer defects and adhesion properties. For the investigation of new coatings, we used cathodic arc deposition (Arc-PVD) to generate TiN, ZrN similar to the currently commercially available coatings and three different diamond like carbon (DLC) coatings on CoCrMo substrate. All surface coatings were mechanically specified by measuring roughness, coating thickness, abrasive wear and critical loads. A friction wear test was modified using an UHMWPE counterpart with a contact pressure of 10 MPa to compare different coatings in one tribological test setup. Calf serum was used as lubricant. The commercially used coatings on the retrieved explants show several defects and the critical load for coating failure varied widely. All produced surface coatings showed an increased surface roughness after coating compared to uncoated samples, which was due to droplet formation, especially in the DLC coatings. A diamond post-polishing process was performed to reduce the surface roughness and reach the ISO standard of Ra < 50 nm. The ZrN and TiN coatings exhibited a decreased friction after removing of the droplets in comparison to uncoated CoCrMo samples, indicating that the post-polishing process might be a useful tool to ameliorate the tribological performance. The friction coefficient for all tested DLC layers was more than two times increased compared to the CoCrMo samples. The use of hard/soft bearings with DLC coated endoprostheses seems to be not advantageous.
Collapse
Affiliation(s)
- Joachim Döring
- Department of Orthopaedic Surgery, Medical Faculty, Otto-von-Guericke-University Magdeburg, Leipziger Straße 44, 39120, Magdeburg, Germany.
| | - Maria Crackau
- Department of Orthopaedic Surgery, Medical Faculty, Otto-von-Guericke-University Magdeburg, Leipziger Straße 44, 39120, Magdeburg, Germany
| | - Christian Nestler
- Department of Orthopaedic Surgery, Medical Faculty, Otto-von-Guericke-University Magdeburg, Leipziger Straße 44, 39120, Magdeburg, Germany; Institute of Manufacturing Technology and Quality Management, Otto-von-Guericke-University Magdeburg, Universitätsplatz 2, 39106, Magdeburg, Germany
| | - Florian Welzel
- Institute of Manufacturing Technology and Quality Management, Otto-von-Guericke-University Magdeburg, Universitätsplatz 2, 39106, Magdeburg, Germany
| | - Jessica Bertrand
- Department of Orthopaedic Surgery, Medical Faculty, Otto-von-Guericke-University Magdeburg, Leipziger Straße 44, 39120, Magdeburg, Germany
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Medical Faculty, Otto-von-Guericke-University Magdeburg, Leipziger Straße 44, 39120, Magdeburg, Germany
| |
Collapse
|
44
|
Römmelt C, Munsch T, Drynda A, Lessmann V, Lohmann CH, Bertrand J. Periprosthetic hypoxia as consequence of TRPM7 mediated cobalt influx in osteoblasts. J Biomed Mater Res B Appl Biomater 2018; 107:1806-1813. [PMID: 30508321 DOI: 10.1002/jbm.b.34273] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2018] [Revised: 08/03/2018] [Accepted: 10/07/2018] [Indexed: 01/05/2023]
Abstract
The reasons for the high number of loosened metal-on-metal (MoM) hip implants are still not fully understood. Hypoxia-inducible factor 1 (HIF-1) mediated signaling pathways, which normally modulate tissue metabolism under hypoxic circumstances, could be triggered by metallic wear debris and influence bone metabolism favoring osteolysis. This may lead to early loosening of the orthopedic implants. Immunhistochemical staining of periprosthetic tissues of failed artificial hip implants showed that the concentration of HIF-1α in the surrounding tissues of failed MoM hip implants was significantly higher in comparison to failed metal-on-polyethylene (MoP) hip implants and osteoarthritic tissues. Therefore, we examined the Co2+ -uptake mechanisms and the influence of Co2+ uptake on HIF-1α stabilization. Based on cobalt mediated quenching effects, calcium imaging experiments using fura-2 showed a concentration-dependent cobalt influx in MG-63 cells, which could be inhibited by the unspecific TRPM7 channel inhibitor 2-APB (20 μM) and TRPM7 specific siRNA. Western blots confirmed a dose dependent increase of HIF-1α upon stimulation with Co2+ . This effect could be abrogated by inhibition of cobalt influx using 2-APB. This study shows that chemical hypoxia originating from HIF-1α upregulation within the periprosthetic tissue is related to cobalt wear debris and highlights TRPM7 as an important key mediator in this context. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1806-1813, 2019.
Collapse
Affiliation(s)
- Constantin Römmelt
- Department of Orthopaedic Surgery, Otto-von-Guericke University, 39120, Magdeburg, Germany
| | - Thomas Munsch
- Institute of Physiology, Otto-von-Guericke University, 39120, Magdeburg, Germany.,Center for Behavioral Brain Sciences (CBBS), 39120, Magdeburg, Germany
| | - Andreas Drynda
- Department of Orthopaedic Surgery, Otto-von-Guericke University, 39120, Magdeburg, Germany
| | - Volkmar Lessmann
- Institute of Physiology, Otto-von-Guericke University, 39120, Magdeburg, Germany.,Center for Behavioral Brain Sciences (CBBS), 39120, Magdeburg, Germany
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University, 39120, Magdeburg, Germany
| | - Jessica Bertrand
- Department of Orthopaedic Surgery, Otto-von-Guericke University, 39120, Magdeburg, Germany
| |
Collapse
|
45
|
Chamaon K, Schönfeld P, Awiszus F, Bertrand J, Lohmann CH. Ionic cobalt but not metal particles induces ROS generation in immune cells in vitro. J Biomed Mater Res B Appl Biomater 2018; 107:1246-1253. [PMID: 30261124 DOI: 10.1002/jbm.b.34217] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2018] [Revised: 07/31/2018] [Accepted: 08/02/2018] [Indexed: 12/25/2022]
Abstract
Total joint replacement is one of the most successful procedures in orthopedic surgery today. However, metal implant materials undergo wear and corrosion processes. Generated particles and ions can cause a variety of cellular reactions. Cobalt-containing alloys are used frequently in implant materials. Some studies suggest that cobalt exhibits potential cytotoxic effects, for example, via generation of reactive oxygen species (ROS). To further elucidate the effects of cobalt on human cells, we determined cell viability and cytosolic and mitochondrial superoxide formation after incubation of either ions or particles with different cells. MM-6 and Jurkat cell lines were treated for 24, 48 and 72 h with either CoCrMo particles or cobalt ions (supplied as CoCl2 ). A total of 24 h exposure of both forms of cobalt did not induce cell death using terminal deoxynucleotidyl transferase (TUNEL) and trypan blue assay. Interestingly, the formation of superoxide (O2 .- ) is evoked mainly by ionic CoCl2 but not cobalt particles. Cobalt alloy particles are likely to even suppress O2 .- formation in mitochondria in both used cell lines. Furthermore, we did not observe any effect of cobalt particles on O2 .- formation in peripheral blood mononuclear cells (PBMCs) from healthy donors. We also found that the O2 - formation by CoCl2 within mitochondria is a generalized effect for all cell types used, while the formation of superoxide in cytosolic compartment is cell-type dependent. In summary, our data suggest that cobalt ions specifically induce the formation of O2 .- , whereas the cobalt particles were better tolerated. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1246-1253, 2019.
Collapse
Affiliation(s)
- Kathrin Chamaon
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Leipziger Str. 44, 39120, Magdeburg, Germany
| | - Peter Schönfeld
- Institute for Biochemistry and Cell Biology, Otto-von-Guericke University, Leipziger Str. 44, 39120, Magdeburg, Germany
| | - Friedemann Awiszus
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Leipziger Str. 44, 39120, Magdeburg, Germany
| | - Jessica Bertrand
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Leipziger Str. 44, 39120, Magdeburg, Germany
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Leipziger Str. 44, 39120, Magdeburg, Germany
| |
Collapse
|
46
|
Hameister R, Lim CT, Lohmann CH, Wang W, Singh G. What Is the Role of Diagnostic and Therapeutic Sonication in Periprosthetic Joint Infections? J Arthroplasty 2018; 33:2575-2581. [PMID: 29599035 DOI: 10.1016/j.arth.2018.02.077] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2017] [Revised: 02/17/2018] [Accepted: 02/20/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Periprosthetic joint infection (PJI) is one of the most dreaded complications in joint replacement surgery. Diagnosis and treatment can be difficult and biofilms are of major concern due to their low susceptibility toward antibiotics. METHODS This review focuses on the use of sonication as an evolving diagnostic and adjunct treatment modality in the context of PJI. Therapeutic application of sonication is discussed separately for its (i) direct action on bacteria, (ii) synergistic effects with antibiotics, and (iii) effects on release of antibiotics from bone cement. RESULTS Used as a diagnostic tool, sonication shows promising results with respect to sensitivity and specificity when compared to conventional methods, notably after previous administration of antibiotics. As an adjunct treatment modality, the chemical, physical, and mechanical effects of sonication are primarily driven by cavitation and recognized as the main cause for bactericidal effects but the exact underlying mechanisms have not been identified yet. Sonication alone does not have the ability to completely eradicate biofilms but synergistic effects when used in conjunction with antibiotics have been reported. There is also evidence for enhanced antibiotic release from bone cement. CONCLUSION Sonication is as an evolving modality in the context of PJIs. As a diagnostic tool, it has not been introduced in routine clinical practice and sonication as a treatment modality in PJIs is still in an experimental stage. Factors such as frequency, pressure, chemical activity, intensity, and exposure time need to be evaluated for optimal application of sonication and may also improve study comparison.
Collapse
Affiliation(s)
- Rita Hameister
- Department of Anatomy, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Chin T Lim
- National University Health System, University Orthopaedics, Hand and Reconstructive Microsurgery Cluster, Singapore, Singapore
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto von Guericke University Magdeburg, Magdeburg, Germany
| | - Wilson Wang
- National University Health System, University Orthopaedics, Hand and Reconstructive Microsurgery Cluster, Singapore, Singapore
| | - Gurpal Singh
- National University Health System, University Orthopaedics, Hand and Reconstructive Microsurgery Cluster, Singapore, Singapore
| |
Collapse
|
47
|
Held A, Glas A, Dietrich L, Bollmann M, Brandstädter K, Grossmann TN, Lohmann CH, Pap T, Bertrand J. Targeting β-catenin dependent Wnt signaling via peptidomimetic inhibitors in murine chondrocytes and OA cartilage. Osteoarthritis Cartilage 2018; 26:818-823. [PMID: 29559252 DOI: 10.1016/j.joca.2018.02.908] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/05/2017] [Revised: 02/21/2018] [Accepted: 02/27/2018] [Indexed: 02/02/2023]
Abstract
OBJECTIVE The canonical Wnt signaling pathway has been shown to be involved in regulating chondrocyte hypertrophic differentiation during Osteoarthritis (OA). The aim of this study was to test the therapeutic potential of two stapled peptide canonical Wnt inhibitors - SAH-Bcl9 and StAx-35R - in preventing Wnt induced cartilage changes in OA. METHODS Primary neonatal murine chondrocytes and cartilage explants from OA patients undergoing total joint replacement for knee OA, were used for microscopy to determine matrix and cell penetrating capacity of fluorescein isothiocyanate FITC-tagged SAH-Bcl9 and StAx-35R peptides. T cell factor/lymphoid enhancer-binding factor (TCF/LEF) reporter assays were used to monitor the inhibition of Wnt3a induced β-catenin signaling by each peptide. Changes in chondrocyte phenotypic marker gene expression were analyzed by qRT PCR. RESULTS Both peptides localized intercellular in primary murine chondrocytes and cartilage explants. They inhibited Wnt3a induced TCF/LEF promoter activity in primary murine chondrocytes. Both inhibitors did not rescue Wnt3a altered expression of chondrocyte phenotypic genes (Sox9, Col2a1, Acan) and hypertrophy marker gene (Col10a1) at high doses (100 ng/ml). Upon application of 10 ng/ml Wnt3a, StAx-35R partially reversed the Wnt effect on Sox9 and Col2a1 gene expression. Both peptides, however, reversed the downregulation of SOX9 and aggrecan (ACAN), and decrease of COL10A1 gene expression in preserved human OA cartilage explants. CONCLUSION These data indicate that blockade of canonical Wnt signaling might be a therapeutic strategy to treat early OA cases and protect further cartilage degradation by preventing chondrocyte hypertrophic differentiation.
Collapse
Affiliation(s)
- A Held
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - A Glas
- Chemical Genomics Centre of the Max-Planck Society, Dortmund, Germany
| | - L Dietrich
- Chemical Genomics Centre of the Max-Planck Society, Dortmund, Germany
| | - M Bollmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - K Brandstädter
- Institute of Forensic Medicine, University Hospital Halle, Remote Office Magdeburg, Halle (Saale), Magdeburg, Germany
| | - T N Grossmann
- Chemical Genomics Centre of the Max-Planck Society, Dortmund, Germany; Department of Chemistry and Pharmaceutical Science, VU University Amsterdam, Amsterdam, The Netherlands
| | - C H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - T Pap
- Institute of Experimental Musculoskeletal Medicine, University Hospital Münster, Münster, Germany
| | - J Bertrand
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany.
| |
Collapse
|
48
|
Vogel M, Riediger C, Illiger S, Frenzel L, Frommer J, Lohmann CH. Using Borderline Personality Organization to Predict Outcome after Total Knee Arthroplasty. Psychother Psychosom 2018; 86:183-184. [PMID: 28490017 DOI: 10.1159/000454927] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/05/2016] [Accepted: 12/03/2016] [Indexed: 11/19/2022]
Affiliation(s)
- Matthias Vogel
- Universitätsklinik für Psychosomatische Medizin und Psychotherapie, Magdeburg, Germany
| | | | | | | | | | | |
Collapse
|
49
|
Drynda S, Drynda A, Feuerstein B, Kekow J, Lohmann CH, Bertrand J. The effects of cobalt and chromium ions on transforming growth factor-beta patterns and mineralization in human osteoblast-like MG63 and SaOs-2 cells. J Biomed Mater Res A 2018; 106:2105-2115. [DOI: 10.1002/jbm.a.36409] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2018] [Revised: 03/11/2018] [Accepted: 03/15/2018] [Indexed: 01/04/2023]
Affiliation(s)
- Susanne Drynda
- Department of Orthopaedic Surgery; Otto-von-Guericke University; Magdeburg Germany
- Clinic for Rheumatology, Otto-von-Guericke University; Magdeburg Germany
| | - Andreas Drynda
- Department of Orthopaedic Surgery; Otto-von-Guericke University; Magdeburg Germany
| | - Bernd Feuerstein
- Department of Mechanical Engineering; Magdeburg-Stendal University of Applied Sciences; Magdeburg Germany
| | - Jörn Kekow
- Clinic for Rheumatology, Otto-von-Guericke University; Magdeburg Germany
| | - Christoph H. Lohmann
- Department of Orthopaedic Surgery; Otto-von-Guericke University; Magdeburg Germany
| | - Jessica Bertrand
- Department of Orthopaedic Surgery; Otto-von-Guericke University; Magdeburg Germany
| |
Collapse
|
50
|
Stärke F, Awiszus F, Lohmann CH, Stärke C. The effect of irrigation time and type of irrigation fluid on cartilage surface friction. J Mech Behav Biomed Mater 2017; 77:187-191. [PMID: 28926768 DOI: 10.1016/j.jmbbm.2017.09.008] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2017] [Revised: 08/29/2017] [Accepted: 09/04/2017] [Indexed: 11/18/2022]
Abstract
It is known that fluid irrigation used during arthroscopic procedures causes a wash-out of lubricating substances from the articular cartilage surface and leads to increased friction. It was the goal of this study to investigate whether this effect depends on the time of irrigation and type of fluid used. Rabbit hind legs were used for the tests. The knees were dissected and the friction coefficient of the femoral cartilage measured against glass in a boundary lubrication state. To determine the influence of irrigation time and fluid, groups of 12 knees received either no irrigation (control), 15, 60 or 120min of irrigation with lactated Ringer's solution or 60min of irrigation with normal saline or a sorbitol/mannitol solution. The time of irrigation had a significant effect on the static and kinetic coefficient of friction (CoF), as had the type of fluid. Longer irrigation time with Ringer's solution was associated with increased friction coefficients (relative increase of the kinetic CoF compared to the control after 15, 60 and 120min: 16%, 76% and 88% respectively). The sorbitol/mannitol solution affected the static and kinetic CoF significantly less than either Ringer's or normal saline. The washout of lubricating glycoproteins from the cartilage surface and the associated increase of friction can be effectively influenced by controlling the time of irrigation and type of fluid used. The time of exposure to the irrigation fluid should be as short as possible and monosaccharide solutions might offer a benefit compared to salt solutions in terms of the resultant friction.
Collapse
Affiliation(s)
- F Stärke
- Orthopedics Department, University Hospital Magdeburg, Leipziger Straße 44, 39120 Magdeburg, Germany
| | - F Awiszus
- Orthopedics Department, University Hospital Magdeburg, Leipziger Straße 44, 39120 Magdeburg, Germany
| | - C H Lohmann
- Orthopedics Department, University Hospital Magdeburg, Leipziger Straße 44, 39120 Magdeburg, Germany
| | - C Stärke
- Orthopedics Department, University Hospital Magdeburg, Leipziger Straße 44, 39120 Magdeburg, Germany.
| |
Collapse
|