Wearne LS, Rapagna S, Awadalla M, Keene G, Taylor M, Perilli E. Quantifying the immediate post-implantation strain field of cadaveric tibiae implanted with cementless tibial trays: A time-elapsed micro-CT and digital volume correlation analysis during stair descent. J Mech Behav Biomed Mater 2024; 151:106347. [PMID: 38181568 DOI: 10.1016/j.jmbbm.2023.106347] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 12/18/2023] [Accepted: 12/22/2023] [Indexed: 01/07/2024]
Abstract
Primary stability, the mechanical fixation between implant and bone prior to osseointegration, is crucial for the long-term success of cementless tibial trays. However, little is known about the mechanical interplay between the implant and bone internally, as experimental studies quantifying internal strain are limited. This study employed digital volume correlation (DVC) to quantify the immediate post-implantation strain field of five cadaveric tibiae implanted with a commercially available cementless titanium tibial tray (Attune, DePuy Synthes). The tibiae were subjected to a five-step loading sequence (0-2.5 bodyweight, BW) replicating stair descent, with concomitant time-elapsed micro-CT imaging. With progressive loads, increased compression of trabecular bone was quantified, with the highest strains directly under the posterior region of the tibial tray implant, dissipating with increasing distance from the bone-implant interface. After load removal of the last load step (2.5BW), residual strains were observed in all of the five tibiae, with residual strains confined within 3.14 mm from the bone-implant interface. The residual strain is reflective of the observed initial migration of cementless tibial trays reported in clinical studies. The presence of strains above the yield strain of bone accepted in literature suggests that inelastic properties should be included within finite element models of the initial mechanical environment. This study provides a means to experimentally quantify the internal strain distribution of human tibia with cementless trays, increasing the understanding of the mechanical interaction between bone and implant.
Collapse
Affiliation(s)
- Lauren S Wearne
- Medical Device Research Institute, College of Science and Engineering, Flinders University, Adelaide, South Australia, Australia
| | - Sophie Rapagna
- Medical Device Research Institute, College of Science and Engineering, Flinders University, Adelaide, South Australia, Australia; Flinders Microscopy and Microanalysis, College of Science and Engineering, Flinders University, Adelaide, South Australia, Australia
| | - Maged Awadalla
- Medical Device Research Institute, College of Science and Engineering, Flinders University, Adelaide, South Australia, Australia
| | - Greg Keene
- Orthopaedic Department, SportsMed, Adelaide, South Australia, Australia
| | - Mark Taylor
- Medical Device Research Institute, College of Science and Engineering, Flinders University, Adelaide, South Australia, Australia
| | - Egon Perilli
- Medical Device Research Institute, College of Science and Engineering, Flinders University, Adelaide, South Australia, Australia.
| |
Collapse
|
2
|
Palanca M, Cavazzoni G, Dall'Ara E. The role of bone metastases on the mechanical competence of human vertebrae. Bone 2023:116814. [PMID: 37257631 DOI: 10.1016/j.bone.2023.116814] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 05/03/2023] [Accepted: 05/23/2023] [Indexed: 06/02/2023]
Abstract
Spine is the most common site for bone metastases. The evaluation of the mechanical competence and failure location in metastatic vertebrae is a biomechanical and clinical challenge. Little is known about the failure behaviour of vertebrae with metastatic lesions. The aim of this study was to use combined micro-Computed Tomography (microCT) and time-lapsed mechanical testing to reveal the failure location in metastatic vertebrae. Fifteen spine segments, each including a metastatic and a radiologically healthy vertebra, were tested in compression up to failure within a microCT. Volumetric strains were measured using Digital Volume Correlation. The images of undeformed and deformed specimens were overlapped to identify the failure location. Vertebrae with lytic metastases experienced the largest average compressive strains (median ± standard deviation: -8506 ± 4748microstrain), followed by the vertebrae with mixed metastases (-7035 ± 15605microstrain), the radiologically healthy vertebrae (-5743 ± 5697microstrain), and the vertebrae with blastic metastases (-3150 ± 4641microstrain). Strain peaks were localised within and nearby the lytic lesions or around the blastic tissue. Failure between the endplate and the metastasis was identified in vertebrae with lytic metastases, whereas failure localised around the metastasis in vertebrae with blastic lesions. This study showed for the first time the role of metastases on the vertebral internal deformations. While lytic lesions lead to failure of the metastatic vertebra, vertebrae with blastic metastases are more likely to induce failure in the adjacent vertebrae. Nevertheless, every metastatic lesion affects the vertebral deformation differently, making it essential to assess how the lesion affects the bone microstructure. These results suggest that the properties of the lesion (type, size, location within the vertebral body) should be considered when developing clinical tools to predict the risk of fracture in patients with metastatic lesions.
Collapse
Affiliation(s)
- Marco Palanca
- Dept of Oncology and Metabolism, The University of Sheffield, Sheffield, UK; INSIGNEO Institute for In Silico Medicine, The University of Sheffield, Sheffield, UK; Dept of Industrial Engineering, Alma Mater Studiorum - University of Bologna, Bologna, Italy.
| | - Giulia Cavazzoni
- Dept of Oncology and Metabolism, The University of Sheffield, Sheffield, UK; INSIGNEO Institute for In Silico Medicine, The University of Sheffield, Sheffield, UK; Dept of Industrial Engineering, Alma Mater Studiorum - University of Bologna, Bologna, Italy
| | - Enrico Dall'Ara
- Dept of Oncology and Metabolism, The University of Sheffield, Sheffield, UK; INSIGNEO Institute for In Silico Medicine, The University of Sheffield, Sheffield, UK
| |
Collapse
|
3
|
Cavazzoni G, Cristofolini L, Dall’Ara E, Palanca M. Bone metastases do not affect the measurement uncertainties of a global digital volume correlation algorithm. Front Bioeng Biotechnol 2023; 11:1152358. [PMID: 37008039 PMCID: PMC10060622 DOI: 10.3389/fbioe.2023.1152358] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Accepted: 03/06/2023] [Indexed: 03/18/2023] Open
Abstract
Introduction: Measurement uncertainties of Digital Volume Correlation (DVC) are influenced by several factors, like input images quality, correlation algorithm, bone type, etc. However, it is still unknown if highly heterogeneous trabecular microstructures, typical of lytic and blastic metastases, affect the precision of DVC measurements.Methods: Fifteen metastatic and nine healthy vertebral bodies were scanned twice in zero-strain conditions with a micro-computed tomography (isotropic voxel size = 39 μm). The bone microstructural parameters (Bone Volume Fraction, Structure Thickness, Structure Separation, Structure Number) were calculated. Displacements and strains were evaluated through a global DVC approach (BoneDVC). The relationship between the standard deviation of the error (SDER) and the microstructural parameters was investigated in the entire vertebrae. To evaluate to what extent the measurement uncertainty is influenced by the microstructure, similar relationships were assessed within sub-regions of interest.Results: Higher variability in the SDER was found for metastatic vertebrae compared to the healthy ones (range 91-1030 με versus 222–599 με). A weak correlation was found between the SDER and the Structure Separation in metastatic vertebrae and in the sub-regions of interest, highlighting that the heterogenous trabecular microstructure only weakly affects the measurement uncertainties of BoneDVC. No correlation was found for the other microstructural parameters. The spatial distribution of the strain measurement uncertainties seemed to be associated with regions with reduced greyscale gradient variation in the microCT images.Discussion: Measurement uncertainties cannot be taken for granted but need to be assessed in each single application of the DVC to consider the minimum unavoidable measurement uncertainty when interpreting the results.
Collapse
Affiliation(s)
- Giulia Cavazzoni
- Department of Industrial Engineering, School of Engineering and Architecture, Alma Mater Studiorum-University of Bologna, Bologna, Italy
- Department of Oncology and Metabolism, The University of Sheffield, Sheffield, United Kingdom
- INSIGNEO Institute for in Silico Medicine, The University of Sheffield, Sheffield, United Kingdom
| | - Luca Cristofolini
- Department of Industrial Engineering, School of Engineering and Architecture, Alma Mater Studiorum-University of Bologna, Bologna, Italy
| | - Enrico Dall’Ara
- Department of Oncology and Metabolism, The University of Sheffield, Sheffield, United Kingdom
- INSIGNEO Institute for in Silico Medicine, The University of Sheffield, Sheffield, United Kingdom
| | - Marco Palanca
- Department of Industrial Engineering, School of Engineering and Architecture, Alma Mater Studiorum-University of Bologna, Bologna, Italy
- Department of Oncology and Metabolism, The University of Sheffield, Sheffield, United Kingdom
- INSIGNEO Institute for in Silico Medicine, The University of Sheffield, Sheffield, United Kingdom
- *Correspondence: Marco Palanca,
| |
Collapse
|
4
|
Dall'Ara E, Bodey AJ, Isaksson H, Tozzi G. A practical guide for in situ mechanical testing of musculoskeletal tissues using synchrotron tomography. J Mech Behav Biomed Mater 2022; 133:105297. [PMID: 35691205 DOI: 10.1016/j.jmbbm.2022.105297] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2022] [Revised: 05/03/2022] [Accepted: 05/25/2022] [Indexed: 02/07/2023]
Abstract
Musculoskeletal tissues are complex hierarchical materials where mechanical response is linked to structural and material properties at different dimensional levels. Therefore, high-resolution three-dimensional tomography is very useful for assessing tissue properties at different scales. In particular, Synchrotron Radiation micro-Computed Tomography (SR-microCT) has been used in several applications to analyze the structure of bone and biomaterials. In the past decade the development of digital volume correlation (DVC) algorithms applied to SR-microCT images and its combination with in situ mechanical testing (four-dimensional imaging) have allowed researchers to visualise, for the first time, the deformation of musculoskeletal tissues and their interaction with biomaterials under different loading scenarios. However, there are several experimental challenges that make these measurements difficult and at high risk of failure. Challenges relate to sample preparation, imaging parameters, loading setup, accumulated tissue damage for multiple tomographic acquisitions, reconstruction methods and data processing. Considering that access to SR-microCT facilities is usually associated with bidding processes and long waiting times, the failure of these experiments could notably slow down the advancement of this research area and reduce its impact. Many of the experimental failures can be avoided with increased experience in performing the tests and better guidelines for preparation and execution of these complex experiments; publication of negative results could help interested researchers to avoid recurring mistakes. Therefore, the goal of this article is to highlight the potential and pitfalls in the design and execution of in situ SR-microCT experiments, involving multiple scans, of musculoskeletal tissues for the assessment of their structural and/or mechanical properties. The advice and guidelines that follow should improve the success rate of this type of experiment, allowing the community to reach higher impact more efficiently.
Collapse
Affiliation(s)
- E Dall'Ara
- Department of Oncology and Metabolism, Mellanby Centre for Bone Research, University of Sheffield, UK; INSIGNEO Institute for in Silico Medicine, University of Sheffield, UK.
| | | | - H Isaksson
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - G Tozzi
- School of Engineering, London South Bank University, London, UK
| |
Collapse
|
5
|
Kok J, Törnquist E, Raina DB, Le Cann S, Novak V, Širka A, Lidgren L, Grassi L, Isaksson H. Fracture behavior of a composite of bone and calcium sulfate/hydroxyapatite. J Mech Behav Biomed Mater 2022; 130:105201. [DOI: 10.1016/j.jmbbm.2022.105201] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Revised: 03/19/2022] [Accepted: 03/25/2022] [Indexed: 12/12/2022]
|
6
|
Dall'Ara E, Tozzi G. Digital volume correlation for the characterization of musculoskeletal tissues: Current challenges and future developments. Front Bioeng Biotechnol 2022; 10:1010056. [PMID: 36267445 PMCID: PMC9577231 DOI: 10.3389/fbioe.2022.1010056] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2022] [Accepted: 09/20/2022] [Indexed: 11/13/2022] Open
Abstract
Biological tissues are complex hierarchical materials, difficult to characterise due to the challenges associated to the separation of scale and heterogeneity of the mechanical properties at different dimensional levels. The Digital Volume Correlation approach is the only image-based experimental approach that can accurately measure internal strain field within biological tissues under complex loading scenarios. In this minireview examples of DVC applications to study the deformation of musculoskeletal tissues at different dimensional scales are reported, highlighting the potential and challenges of this relatively new technique. The manuscript aims at reporting the wide breath of DVC applications in the past 2 decades and discuss future perspective for this unique technique, including fast analysis, applications on soft tissues, high precision approaches, and clinical applications.
Collapse
Affiliation(s)
- Enrico Dall'Ara
- Department of Oncology and Metabolism, Mellanby Centre for Bone Research, University of Sheffield, Sheffield, United Kingdom.,INSIGNEO Institute for in Silico Medicine, University of Sheffield, Sheffield, United Kingdom
| | - Gianluca Tozzi
- School of Engineering, University of Greenwich, Chatham Maritime, United Kingdom
| |
Collapse
|
7
|
Palanca M, Oliviero S, Dall'Ara E. MicroFE models of porcine vertebrae with induced bone focal lesions: Validation of predicted displacements with digital volume correlation. J Mech Behav Biomed Mater 2022; 125:104872. [PMID: 34655942 DOI: 10.1016/j.jmbbm.2021.104872] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 09/21/2021] [Accepted: 09/30/2021] [Indexed: 12/16/2022]
Abstract
The evaluation of the local mechanical behavior as a result of metastatic lesions is fundamental for the characterization of the mechanical competence of metastatic vertebrae. Micro finite element (microFE) models have the potential of addressing this challenge through laboratory studies but their predictions of local deformation due to the complexity of the bone structure compromized by the lesion must be validated against experiments. In this study, the displacements predicted by homogeneous, linear and isotropic microFE models of vertebrae were validated against experimental Digital Volume Correlation (DVC) measurements. Porcine spine segments, with and without mechanically induced focal lesions, were tested in compression within a micro computed tomography (microCT) scanner. The displacement within the bone were measured with an optimized global DVC approach (BoneDVC). MicroFE models of the intact and lesioned vertebrae, including or excluding the growth plates, were developed from the microCT images. The microFE and DVC boundary conditions were matched. The displacements measured by the DVC and predicted by the microFE along each Cartesian direction were compared. The results showed an excellent agreement between the measured and predicted displacements, both for intact and metastatic vertebrae, in the middle of the vertebra, in those cases where the structure was not loaded beyond yield (0.69 < R2 < 1.00). Models with growth plates showed the worst correlations (0.02 < R2 < 0.99), while a clear improvement was observed if the growth plates were excluded (0.56 < R2 < 1.00). In conclusion, these simplified models can predict complex displacement fields in the elastic regime with high reliability, more complex non-linear models should be implemented to predict regions with high deformation, when the bone is loaded beyond yield.
Collapse
Affiliation(s)
- Marco Palanca
- Dept of Oncology and Metabolism, And INSIGNEO Institute for in silico medicine, University of Sheffield, Sheffield, UK.
| | - Sara Oliviero
- Dept of Oncology and Metabolism, And INSIGNEO Institute for in silico medicine, University of Sheffield, Sheffield, UK
| | - Enrico Dall'Ara
- Dept of Oncology and Metabolism, And INSIGNEO Institute for in silico medicine, University of Sheffield, Sheffield, UK
| |
Collapse
|
8
|
Time-resolved in situ synchrotron-microCT: 4D deformation of bone and bone analogues using digital volume correlation. Acta Biomater 2021; 131:424-439. [PMID: 34126266 DOI: 10.1016/j.actbio.2021.06.014] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2021] [Revised: 05/07/2021] [Accepted: 06/07/2021] [Indexed: 02/08/2023]
Abstract
Digital volume correlation (DVC) in combination with high-resolution micro-computed tomography (microCT) imaging and in situ mechanical testing is gaining popularity for quantifying 3D full-field strains in bone and biomaterials. However, traditional in situ time-lapsed (i.e., interrupted) mechanical testing cannot fully capture the dynamic strain mechanisms in viscoelastic biological materials. The aim of this study was to investigate the time-resolved deformation of bone structures and analogues via continuous in situ synchrotron-radiation microCT (SR-microCT) compression and DVC to gain a better insight into their structure-function relationships. Fast SR-microCT imaging enabled the deformation behaviour to be captured with high temporal and spatial resolution. Time-resolved DVC highlighted the relationship between local strains and damage initiation and progression in the different biostructures undergoing plastic deformation, bending and/or buckling of their main microstructural elements. The results showed that SR-microCT continuous mechanical testing complemented and enhanced the information obtained from time-lapsed testing, which may underestimate the 3D strain magnitudes as a result of the stress relaxation occurring in between steps before image acquisition in porous biomaterials. Altogether, the findings of this study highlight the importance of time-resolved in situ experiments to fully characterise the time-dependent mechanical behaviour of biological tissues and biomaterials and to further explore their micromechanics under physiologically relevant conditions. STATEMENT OF SIGNIFICANCE: Time-resolved synchrotron X-ray tomography in combination with in situ mechanical testing provided the first four-dimensional analysis of the mechanical deformation of bone and bone analogues. To unravel the interplay of damage initiation and progression with local deformation, digital volume correlation was used to map the local strain field while microstructural changes were tracked with high temporal and spatial resolution. The results highlighted the importance of fast imaging and time-resolved in situ experiments to capture the real deformation of complex porous materials to fully characterize the local strain-damage relationship. The findings are notably improving the understanding of time-dependent mechanical behaviour of bone tissue, with the potential to be extend to highly viscoelastic biomaterials and soft tissues.
Collapse
|
9
|
Palanca M, De Donno G, Dall’Ara E. A novel approach to evaluate the effects of artificial bone focal lesion on the three-dimensional strain distributions within the vertebral body. PLoS One 2021; 16:e0251873. [PMID: 34061879 PMCID: PMC8168867 DOI: 10.1371/journal.pone.0251873] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Accepted: 05/05/2021] [Indexed: 12/14/2022] Open
Abstract
The spine is the first site for incidence of bone metastasis. Thus, the vertebrae have a high potential risk of being weakened by metastatic tissues. The evaluation of strength of the bone affected by the presence of metastases is fundamental to assess the fracture risk. This work proposes a robust method to evaluate the variations of strain distributions due to artificial lesions within the vertebral body, based on in situ mechanical testing and digital volume correlation. Five porcine vertebrae were tested in compression up to 6500N inside a micro computed tomography scanner. For each specimen, images were acquired before and after the application of the load, before and after the introduction of the artificial lesions. Principal strains were computed within the bone by means of digital volume correlation (DVC). All intact specimens showed a consistent strain distribution, with peak minimum principal strain in the range -1.8% to -0.7% in the middle of the vertebra, demonstrating the robustness of the method. Similar distributions of strains were found for the intact vertebrae in the different regions. The artificial lesion generally doubled the strain in the middle portion of the specimen, probably due to stress concentrations close to the defect. In conclusion, a robust method to evaluate the redistribution of the strain due to artificial lesions within the vertebral body was developed and will be used in the future to improve current clinical assessment of fracture risk in metastatic spines.
Collapse
Affiliation(s)
- Marco Palanca
- Dept of Oncology and Metabolism and INSIGNEO Institute for in silico Medicine, The University of Sheffield, Sheffield, United Kingdom
| | - Giulia De Donno
- Dept of Oncology and Metabolism and INSIGNEO Institute for in silico Medicine, The University of Sheffield, Sheffield, United Kingdom
- Dept of Industrial Engineering, Alma Mater Studiorum, Università di Bologna, Bologna, Italy
| | - Enrico Dall’Ara
- Dept of Oncology and Metabolism and INSIGNEO Institute for in silico Medicine, The University of Sheffield, Sheffield, United Kingdom
| |
Collapse
|
10
|
Arora H, Mitchell RL, Johnston R, Manolesos M, Howells D, Sherwood JM, Bodey AJ, Wanelik K. Correlating Local Volumetric Tissue Strains with Global Lung Mechanics Measurements. MATERIALS (BASEL, SWITZERLAND) 2021; 14:439. [PMID: 33477444 PMCID: PMC7829924 DOI: 10.3390/ma14020439] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/21/2020] [Revised: 12/16/2020] [Accepted: 01/13/2021] [Indexed: 12/30/2022]
Abstract
The mechanics of breathing is a fascinating and vital process. The lung has complexities and subtle heterogeneities in structure across length scales that influence mechanics and function. This study establishes an experimental pipeline for capturing alveolar deformations during a respiratory cycle using synchrotron radiation micro-computed tomography (SR-micro-CT). Rodent lungs were mechanically ventilated and imaged at various time points during the respiratory cycle. Pressure-Volume (P-V) characteristics were recorded to capture any changes in overall lung mechanical behaviour during the experiment. A sequence of tomograms was collected from the lungs within the intact thoracic cavity. Digital volume correlation (DVC) was used to compute the three-dimensional strain field at the alveolar level from the time sequence of reconstructed tomograms. Regional differences in ventilation were highlighted during the respiratory cycle, relating the local strains within the lung tissue to the global ventilation measurements. Strains locally reached approximately 150% compared to the averaged regional deformations of approximately 80-100%. Redistribution of air within the lungs was observed during cycling. Regions which were relatively poorly ventilated (low deformations compared to its neighbouring region) were deforming more uniformly at later stages of the experiment (consistent with its neighbouring region). Such heterogenous phenomena are common in everyday breathing. In pathological lungs, some of these non-uniformities in deformation behaviour can become exaggerated, leading to poor function or further damage. The technique presented can help characterize the multiscale biomechanical nature of a given pathology to improve patient management strategies, considering both the local and global lung mechanics.
Collapse
Affiliation(s)
- Hari Arora
- Faculty of Science and Engineering, Swansea University, Swansea SA1 8EN, UK; (R.J.); (M.M.); (D.H.)
| | - Ria L. Mitchell
- Faculty of Engineering, The University of Sheffield, Sheffield S10 2TN, UK;
| | - Richard Johnston
- Faculty of Science and Engineering, Swansea University, Swansea SA1 8EN, UK; (R.J.); (M.M.); (D.H.)
| | - Marinos Manolesos
- Faculty of Science and Engineering, Swansea University, Swansea SA1 8EN, UK; (R.J.); (M.M.); (D.H.)
| | - David Howells
- Faculty of Science and Engineering, Swansea University, Swansea SA1 8EN, UK; (R.J.); (M.M.); (D.H.)
| | - Joseph M. Sherwood
- Department of Bioengineering, Imperial College London, London SW7 2AZ, UK;
| | - Andrew J. Bodey
- Diamond Light Source Ltd., Didcot OX11 0DE, Oxfordshire, UK; (A.J.B.); (K.W.)
| | - Kaz Wanelik
- Diamond Light Source Ltd., Didcot OX11 0DE, Oxfordshire, UK; (A.J.B.); (K.W.)
| |
Collapse
|
11
|
Tavana S, Clark JN, Newell N, Calder JD, Hansen U. In Vivo Deformation and Strain Measurements in Human Bone Using Digital Volume Correlation (DVC) and 3T Clinical MRI. MATERIALS 2020; 13:ma13235354. [PMID: 33255848 PMCID: PMC7728341 DOI: 10.3390/ma13235354] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/25/2020] [Revised: 11/20/2020] [Accepted: 11/23/2020] [Indexed: 12/15/2022]
Abstract
Strains within bone play an important role in the remodelling process and the mechanisms of fracture. The ability to assess these strains in vivo can provide clinically relevant information regarding bone health, injury risk, and can also be used to optimise treatments. In vivo bone strains have been investigated using multiple experimental techniques, but none have quantified 3D strains using non-invasive techniques. Digital volume correlation based on clinical MRI (DVC-MRI) is a non-invasive technique that has the potential to achieve this. However, before it can be implemented, uncertainties associated with the measurements must be quantified. Here, DVC-MRI was evaluated to assess its potential to measure in vivo strains in the talus. A zero-strain test (two repeated unloaded scans) was conducted using three MRI sequences, and three DVC approaches to quantify errors and to establish optimal settings. With optimal settings, strains could be measured with a precision of 200 με and accuracy of 480 με for a spatial resolution of 7.5 mm, and a precision of 133 με and accuracy of 251 με for a spatial resolution of 10 mm. These results demonstrate that this technique has the potential to measure relevant levels of in vivo bone strain and to be used for a range of clinical applications.
Collapse
Affiliation(s)
- Saman Tavana
- Department of Mechanical Engineering, Imperial College London, South Kensington Campus, London SW7 2AZ, UK; (J.N.C.); (N.N.)
- Correspondence: (S.T.); (U.H.); Tel.: +44-(0)20-7594-7061 (U.H.)
| | - Jeffrey N. Clark
- Department of Mechanical Engineering, Imperial College London, South Kensington Campus, London SW7 2AZ, UK; (J.N.C.); (N.N.)
| | - Nicolas Newell
- Department of Mechanical Engineering, Imperial College London, South Kensington Campus, London SW7 2AZ, UK; (J.N.C.); (N.N.)
| | - James D. Calder
- Department of Bioengineering, Imperial College London, London SW7 2AZ, UK;
- Fortius Clinic, 17 Fitzhardinge St, London W1H 6EQ, UK
| | - Ulrich Hansen
- Department of Mechanical Engineering, Imperial College London, South Kensington Campus, London SW7 2AZ, UK; (J.N.C.); (N.N.)
- Correspondence: (S.T.); (U.H.); Tel.: +44-(0)20-7594-7061 (U.H.)
| |
Collapse
|
12
|
Boulanaache Y, Becce F, Farron A, Pioletti DP, Terrier A. Glenoid bone strain after anatomical total shoulder arthroplasty: In vitro measurements with micro-CT and digital volume correlation. Med Eng Phys 2020; 85:48-54. [PMID: 33081963 DOI: 10.1016/j.medengphy.2020.09.009] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2019] [Revised: 08/31/2020] [Accepted: 09/23/2020] [Indexed: 01/09/2023]
Abstract
Glenoid implant loosening remains a major source of failure and concern after anatomical total shoulder arthroplasty (aTSA). It is assumed to be associated with eccentric loading and excessive bone strain, but direct measurement of bone strain after aTSA is not available yet. Therefore, our objective was to develop an in vitro technique for measuring bone strain around a loaded glenoid implant. A custom loading device (1500 N) was designed to fit within a micro-CT scanner, to use digital volume correlation for measuring displacement and calculating strain. Errors were evaluated with three pairs of unloaded scans. The average displacement random error of three pairs of unloaded scans was 6.1 µm. Corresponding systematic and random errors of strain components were less than 806.0 µε and 2039.9 µε, respectively. The average strain accuracy (MAER) and precision (SDER) were 694.3 µε and 440.3 µε, respectively. The loaded minimum principal strain (8738.9 µε) was 12.6 times higher than the MAER (694.3 µε) on average, and was above the MAER for most of the glenoid bone volume (98.1%). Therefore, this technique proves to be accurate and precise enough to eventually compare glenoid implant designs, fixation techniques, or to validate numerical models of specimens under similar loading.
Collapse
Affiliation(s)
- Y Boulanaache
- Laboratory of Biomechanical Orthopedics, Ecole Polytechnique Fédérale de Lausanne, Station 9, 1015 Lausanne, Switzerland
| | - F Becce
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - A Farron
- Service of Orthopedics and Traumatology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - D P Pioletti
- Laboratory of Biomechanical Orthopedics, Ecole Polytechnique Fédérale de Lausanne, Station 9, 1015 Lausanne, Switzerland
| | - A Terrier
- Laboratory of Biomechanical Orthopedics, Ecole Polytechnique Fédérale de Lausanne, Station 9, 1015 Lausanne, Switzerland.
| |
Collapse
|
13
|
Measurement of Internal Implantation Strains in Analogue Bone Using DVC. MATERIALS 2020; 13:ma13184050. [PMID: 32932608 PMCID: PMC7559792 DOI: 10.3390/ma13184050] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/01/2020] [Revised: 09/04/2020] [Accepted: 09/08/2020] [Indexed: 11/16/2022]
Abstract
The survivorship of cementless orthopaedic implants may be related to their initial stability; insufficient press-fit can lead to excessive micromotion between the implant and bone, joint pain, and surgical revision. However, too much interference between implant and bone can produce excessive strains and damage the bone, which also compromises stability. An understanding of the nature and mechanisms of strain generation during implantation would therefore be valuable. Previous measurements of implantation strain have been limited to local discrete or surface measurements. In this work, we devise a Digital Volume Correlation (DVC) methodology to measure the implantation strain throughout the volume. A simplified implant model was implanted into analogue bone media using a customised loading rig, and a micro-CT protocol optimised to minimise artefacts due to the presence of the implant. The measured strains were interpreted by FE modelling of the displacement-controlled implantation, using a bilinear elastoplastic constitutive model for the analogue bone. The coefficient of friction between the implant and bone was determined using the experimental measurements of the reaction force. Large strains at the interface between the analogue bone and implant produced localised deterioration of the correlation coefficient, compromising the ability to measure strains in this region. Following correlation coefficient thresholding (removing strains with a coefficient less than 0.9), the observed strain patterns were similar between the DVC and FE. However, the magnitude of FE strains was approximately double those measured experimentally. This difference suggests the need for improvements in the interface failure model, for example, to account for localised buckling of the cellular analogue bone structure. A further recommendation from this work is that future DVC experiments involving similar geometries and structures should employ a subvolume size of 0.97 mm as a starting point.
Collapse
|
14
|
Tozzi G, Peña Fernández M, Davis S, Karali A, Kao AP, Blunn G. Full-Field Strain Uncertainties and Residuals at the Cartilage-Bone Interface in Unstained Tissues Using Propagation-Based Phase-Contrast XCT and Digital Volume Correlation. MATERIALS (BASEL, SWITZERLAND) 2020; 13:E2579. [PMID: 32516970 PMCID: PMC7321571 DOI: 10.3390/ma13112579] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Revised: 06/02/2020] [Accepted: 06/03/2020] [Indexed: 01/02/2023]
Abstract
A deeper understanding of the cartilage-bone mechanics is fundamental to unravel onset and progression of osteoarthritis, enabling better diagnosis and treatment. The aim of this study is therefore to explore the capability of X-ray computed (XCT) phase-contrast imaging in a lab-based system to enable digital volume correlation (DVC) measurements of unstained cartilage-bone plugs from healthy adult bovines. DVC strain uncertainties were computed for both articular cartilage and mineralized tissue (calcified cartilage and subchondral bone) in the specimens at increasing propagation distances, ranging from absorption up to four times (4× such effective distance. In addition, a process of dehydration and rehydration was proposed to improve feature recognition in XCT of articular cartilage and mechanical properties of this tissue during the process were assessed via micromechanical probing (indentation), which was also used to determine the effect of long X-ray exposure. Finally, full-field strain from DVC was computed to quantify residual strain distribution at the cartilage-bone interface following unconfined compression test (ex situ). It was found that enhanced gray-scale feature recognition at the cartilage-bone interface was achieved using phase-contrast, resulting in reduced DVC strain uncertainties compared to absorption. Residual strains up to ~7000 µε in the articular cartilage were transferred to subchondral bone via the calcified cartilage and micromechanics revealed the predominant effect of long phase-contrast X-ray exposure in reducing both stiffness and hardness of the articular cartilage. The results of this study will pave the way for further development and refinement of the techniques, improving XCT-based strain measurements in cartilage-bone and other soft-hard tissue interfaces.
Collapse
Affiliation(s)
- Gianluca Tozzi
- Zeiss Global Centre, School of Mechanical and Design Engineering, University of Portsmouth, Portsmouth PO1 3DJ, UK; (M.P.F.); (A.K.); (A.P.K.)
| | - Marta Peña Fernández
- Zeiss Global Centre, School of Mechanical and Design Engineering, University of Portsmouth, Portsmouth PO1 3DJ, UK; (M.P.F.); (A.K.); (A.P.K.)
- School of Engineering Sciences, KTH Royal Institute of Technology, 100 44 Stockholm, Sweden
| | - Sarah Davis
- School of Pharmacy and Biomedical Science, University of Portsmouth, Portsmouth PO1 2DT, UK; (S.D.); (G.B.)
| | - Aikaterina Karali
- Zeiss Global Centre, School of Mechanical and Design Engineering, University of Portsmouth, Portsmouth PO1 3DJ, UK; (M.P.F.); (A.K.); (A.P.K.)
| | - Alexander Peter Kao
- Zeiss Global Centre, School of Mechanical and Design Engineering, University of Portsmouth, Portsmouth PO1 3DJ, UK; (M.P.F.); (A.K.); (A.P.K.)
| | - Gordon Blunn
- School of Pharmacy and Biomedical Science, University of Portsmouth, Portsmouth PO1 2DT, UK; (S.D.); (G.B.)
| |
Collapse
|
15
|
Peña Fernández M, Black C, Dawson J, Gibbs D, Kanczler J, Oreffo ROC, Tozzi G. Exploratory Full-Field Strain Analysis of Regenerated Bone Tissue from Osteoinductive Biomaterials. MATERIALS (BASEL, SWITZERLAND) 2020; 13:E168. [PMID: 31906343 PMCID: PMC6981952 DOI: 10.3390/ma13010168] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/24/2019] [Revised: 12/02/2019] [Accepted: 12/28/2019] [Indexed: 12/25/2022]
Abstract
Biomaterials for bone regeneration are constantly under development, and their application in critical-sized defects represents a promising alternative to bone grafting techniques. However, the ability of all these materials to produce bone mechanically comparable with the native tissue remains unclear. This study aims to explore the full-field strain evolution in newly formed bone tissue produced in vivo by different osteoinductive strategies, including delivery systems for BMP-2 release. In situ high-resolution X-ray micro-computed tomography (microCT) and digital volume correlation (DVC) were used to qualitatively assess the micromechanics of regenerated bone tissue. Local strain in the tissue was evaluated in relation to the different bone morphometry and mineralization for specimens (n = 2 p/treatment) retrieved at a single time point (10 weeks in vivo). Results indicated a variety of load-transfer ability for the different treatments, highlighting the mechanical adaptation of bone structure in the early stages of bone healing. Although exploratory due to the limited sample size, the findings and analysis reported herein suggest how the combination of microCT and DVC can provide enhanced understanding of the micromechanics of newly formed bone produced in vivo, with the potential to inform further development of novel bone regeneration approaches.
Collapse
Affiliation(s)
- Marta Peña Fernández
- School of Mechanical and Design Engineering, University of Portsmouth, Portsmouth PO1 3DJ, UK;
| | - Cameron Black
- Bone & Joint Research Group, Centre for Human Development Stem Cells and Regeneration, Faculty of Medicine, University of Southampton, Southampton SO16 6YD, UK; (C.B.); (J.D.); (D.G.); (J.K.); (R.O.C.O.)
| | - Jon Dawson
- Bone & Joint Research Group, Centre for Human Development Stem Cells and Regeneration, Faculty of Medicine, University of Southampton, Southampton SO16 6YD, UK; (C.B.); (J.D.); (D.G.); (J.K.); (R.O.C.O.)
| | - David Gibbs
- Bone & Joint Research Group, Centre for Human Development Stem Cells and Regeneration, Faculty of Medicine, University of Southampton, Southampton SO16 6YD, UK; (C.B.); (J.D.); (D.G.); (J.K.); (R.O.C.O.)
- School of Maritime Science and Engineering, Solent University, Southampton SO14 0YN, UK
| | - Janos Kanczler
- Bone & Joint Research Group, Centre for Human Development Stem Cells and Regeneration, Faculty of Medicine, University of Southampton, Southampton SO16 6YD, UK; (C.B.); (J.D.); (D.G.); (J.K.); (R.O.C.O.)
| | - Richard O. C. Oreffo
- Bone & Joint Research Group, Centre for Human Development Stem Cells and Regeneration, Faculty of Medicine, University of Southampton, Southampton SO16 6YD, UK; (C.B.); (J.D.); (D.G.); (J.K.); (R.O.C.O.)
| | - Gianluca Tozzi
- School of Mechanical and Design Engineering, University of Portsmouth, Portsmouth PO1 3DJ, UK;
| |
Collapse
|
16
|
Peña Fernández M, Dall’Ara E, Bodey AJ, Parwani R, Barber AH, Blunn GW, Tozzi G. Full-Field Strain Analysis of Bone–Biomaterial Systems Produced by the Implantation of Osteoregenerative Biomaterials in an Ovine Model. ACS Biomater Sci Eng 2019; 5:2543-2554. [DOI: 10.1021/acsbiomaterials.8b01044] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Affiliation(s)
- Marta Peña Fernández
- Zeiss Global Centre, School of Mechanical and Design Engineering, University of Portsmouth, Anglesea Building, Anglesea Road, Portsmouth, PO1 3DJ, U.K
| | - Enrico Dall’Ara
- Department of Oncology and Metabolism and INSIGNEO Institute for in silico Medicine, University of Sheffield, The Pam Liversidge Building, Sir Robert Hadfield Building, Mappin Street, Sheffield, S1 3JD, U.K
| | - Andrew J. Bodey
- Diamond Light Source, Diamond House, Harwell Science and Innovation Campus, Fermi Avenue, Didcot, OX11 0DE, U.K
| | - Rachna Parwani
- Zeiss Global Centre, School of Mechanical and Design Engineering, University of Portsmouth, Anglesea Building, Anglesea Road, Portsmouth, PO1 3DJ, U.K
| | - Asa H. Barber
- Zeiss Global Centre, School of Mechanical and Design Engineering, University of Portsmouth, Anglesea Building, Anglesea Road, Portsmouth, PO1 3DJ, U.K
- School of Engineering, London South Bank University, 103 Borough Road, London, SE1 0AA, U.K
| | - Gordon W. Blunn
- School of Pharmacy and Biomedical Sciences, University of Portsmouth, St. Michael’s Building, White Swan Road, Portsmouth, PO1 2DT, U.K
| | - Gianluca Tozzi
- Zeiss Global Centre, School of Mechanical and Design Engineering, University of Portsmouth, Anglesea Building, Anglesea Road, Portsmouth, PO1 3DJ, U.K
| |
Collapse
|
17
|
Huang L, Korhonen RK, Turunen MJ, Finnilä MAJ. Experimental mechanical strain measurement of tissues. PeerJ 2019; 7:e6545. [PMID: 30867989 PMCID: PMC6409087 DOI: 10.7717/peerj.6545] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2018] [Accepted: 01/31/2019] [Indexed: 12/22/2022] Open
Abstract
Strain, an important biomechanical factor, occurs at different scales from molecules and cells to tissues and organs in physiological conditions. Under mechanical strain, the strength of tissues and their micro- and nanocomponents, the structure, proliferation, differentiation and apoptosis of cells and even the cytokines expressed by cells probably shift. Thus, the measurement of mechanical strain (i.e., relative displacement or deformation) is critical to understand functional changes in tissues, and to elucidate basic relationships between mechanical loading and tissue response. In the last decades, a great number of methods have been developed and applied to measure the deformations and mechanical strains in tissues comprising bone, tendon, ligament, muscle and brain as well as blood vessels. In this article, we have reviewed the mechanical strain measurement from six aspects: electro-based, light-based, ultrasound-based, magnetic resonance-based and computed tomography-based techniques, and the texture correlation-based image processing method. The review may help solving the problems of experimental and mechanical strain measurement of tissues under different measurement environments.
Collapse
Affiliation(s)
- Lingwei Huang
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - Rami K Korhonen
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - Mikael J Turunen
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - Mikko A J Finnilä
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland.,Research Unit of Medical Imaging, Physics and Technology, University of Oulu, Oulu, Finland.,Medical Research Center Oulu, Oulu University Hospital, Oulu, Finland
| |
Collapse
|
18
|
Variability in strain distribution in the mice tibia loading model: A preliminary study using digital volume correlation. Med Eng Phys 2018; 62:7-16. [PMID: 30243888 DOI: 10.1016/j.medengphy.2018.09.001] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2017] [Revised: 06/28/2018] [Accepted: 09/02/2018] [Indexed: 01/27/2023]
Abstract
It is well known that bone has an enormous adaptive capacity to mechanical loadings, and to this extent, several in vivo studies on mouse tibia use established cyclic compressive loading protocols to investigate the effects of mechanical stimuli. In these experiments, the applied axial load is well controlled but the positioning of the hind-limb between the loading endcaps may dramatically affect the strain distribution induced on the tibia. In this study, the full field strain distribution induced by a typical in vivo setup on mouse tibiae was investigated through a combination of in situ compressive testing, µCT scanning and a global digital volume correlation (DVC) approach. The precision of the DVC method and the effect of repositioning on the strain distributions were evaluated. Acceptable uncertainties of the DVC approach for the analysis of loaded tibiae (411 ± 58µɛ) were found for nodal spacing of approximately 50 voxels (520 µm). When pairs of in situ preloaded and loaded images were registered, low variability of the strain distributions within the tibia were seen (range of mean differences in principal strains: 585-1800µɛ). On contrary, larger differences were seen after repositioning (range of mean differences in principal strains: 2500-5500µɛ). To conclude, these preliminary results on thee specimens showed that the DVC approach applied to the mouse tibia can be precise enough to evaluate local strain distributions under loads, and that repositioning of the hind-limb within the testing machine can induce large differences in the strain distributions that should be accounted for when modelling this system.
Collapse
|
19
|
Peña Fernández M, Cipiccia S, Dall'Ara E, Bodey AJ, Parwani R, Pani M, Blunn GW, Barber AH, Tozzi G. Effect of SR-microCT radiation on the mechanical integrity of trabecular bone using in situ mechanical testing and digital volume correlation. J Mech Behav Biomed Mater 2018; 88:109-119. [PMID: 30165258 DOI: 10.1016/j.jmbbm.2018.08.012] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2017] [Revised: 07/21/2018] [Accepted: 08/13/2018] [Indexed: 01/06/2023]
Abstract
The use of synchrotron radiation micro-computed tomography (SR-microCT) is becoming increasingly popular for studying the relationship between microstructure and bone mechanics subjected to in situ mechanical testing. However, it is well known that the effect of SR X-ray radiation can considerably alter the mechanical properties of bone tissue. Digital volume correlation (DVC) has been extensively used to compute full-field strain distributions in bone specimens subjected to step-wise mechanical loading, but tissue damage from sequential SR-microCT scans has not been previously addressed. Therefore, the aim of this study is to examine the influence of SR irradiation-induced microdamage on the apparent elastic properties of trabecular bone using DVC applied to in situ SR-microCT tomograms obtained with different exposure times. Results showed how DVC was able to identify high local strain levels (> 10,000 µε) corresponding to visible microcracks at high irradiation doses (~ 230 kGy), despite the apparent elastic properties remained unaltered. Microcracks were not detected and bone plasticity was preserved for low irradiation doses (~ 33 kGy), although image quality and consequently, DVC performance were reduced. DVC results suggested some local deterioration of tissue that might have resulted from mechanical strain concentration further enhanced by some level of local irradiation even for low accumulated dose.
Collapse
Affiliation(s)
- Marta Peña Fernández
- Zeiss Global Centre, School of Engineering, University of Portsmouth, Portsmouth, UK
| | | | - Enrico Dall'Ara
- Department of Oncology and Metabolism and INSIGNEO Institute For in Silico Medicine, University of Sheffield, Sheffield, UK
| | | | - Rachna Parwani
- Zeiss Global Centre, School of Engineering, University of Portsmouth, Portsmouth, UK
| | - Martino Pani
- Zeiss Global Centre, School of Engineering, University of Portsmouth, Portsmouth, UK
| | - Gordon W Blunn
- School of Pharmacy and Biomedical Sciences, University of Portsmouth, Portsmouth, UK
| | - Asa H Barber
- Zeiss Global Centre, School of Engineering, University of Portsmouth, Portsmouth, UK; School of Engineering, London South Bank University, London, UK
| | - Gianluca Tozzi
- Zeiss Global Centre, School of Engineering, University of Portsmouth, Portsmouth, UK.
| |
Collapse
|
20
|
PEÑA FERNÁNDEZ M, BARBER A, BLUNN G, TOZZI G. Optimization of digital volume correlation computation in SR-microCT images of trabecular bone and bone-biomaterial systems. J Microsc 2018; 272:213-228. [DOI: 10.1111/jmi.12745] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2018] [Revised: 06/30/2018] [Accepted: 07/11/2018] [Indexed: 11/28/2022]
Affiliation(s)
| | - A.H. BARBER
- School of Engineering; University of Portsmouth; Portsmouth U.K
- School of Engineering; London South Bank University; U.K
| | - G.W. BLUNN
- School of Pharmacy and Biomedical Sciences; University of Portsmouth; Portsmouth U.K
| | - G. TOZZI
- School of Engineering; University of Portsmouth; Portsmouth U.K
| |
Collapse
|
21
|
Ruspi ML, Palanca M, Faldini C, Cristofolini L. Full-field in vitro investigation of hard and soft tissue strain in the spine by means of Digital Image Correlation. Muscles Ligaments Tendons J 2018; 7:538-545. [PMID: 29721455 DOI: 10.11138/mltj/2017.7.4.538] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Introduction The spine deserves careful biomechanical investigation, because of the different types of degeneration deriving from daily stress, trauma, and hard and soft tissue pathologies. Many biomechanical studies evaluated the range of motion, structural stiffness of spine segments under different loading conditions, without addressing the strain distribution. Strain gauges have been used to measure strain in the vertebral body, in a pointwise way.What is currently missing is a method to measure the distribution of strain in the soft tissues (intervertebral discs and ligaments), and an integration between measurements in the hard and soft tissues. Digital Image Correlation (DIC) is a recently developed optical technique, which allows measuring the distribution of displacements and deformation in a contact-less way. It can provide a full-field view of the examined surface under load. DIC can therefore give a more complete knowledge of the biomechanics of the spine. Methods This study was performed multisegmental porcine spine specimens with two loading configurations (flexion and lateral bending), while DIC was used to measure the strain distribution. The tests showed the different deformation in the vertebral body, intervertebral discs and ligaments in compression and tension. At the same time it was possible to visualize the growth plates, which are Conclusion: Significantly softer than the vertebral bone.This work showed the feasibility of investigating the spine in a full-field way, and to quantify the strain inhomogeneity in the vertebrae and soft tissues. Therefore DIC can help improve implantable devices and the surgical technique.
Collapse
Affiliation(s)
- Maria Luisa Ruspi
- Department of Industrial Engineering, School of Engineering and Architecture, Alma Mater Studiorum-University of Bologna, Bologna, Italy
| | - Marco Palanca
- Department of Industrial Engineering, School of Engineering and Architecture, Alma Mater Studiorum-University of Bologna, Bologna, Italy
| | - Cesare Faldini
- Department of Biomedical and Neuromotor Sciences, Alma Mater Studiorum University of Bologna, Italy.,2 Orthopaedic and Traumatologic Clinic, Rizzoli Orthopaedic Institute
| | - Luca Cristofolini
- Department of Industrial Engineering, School of Engineering and Architecture, Alma Mater Studiorum-University of Bologna, Bologna, Italy
| |
Collapse
|
22
|
DANESI VALENTINA, FALDINI CESARE, CRISTOFOLINI LUCA. METHODS FOR THE CHARACTERIZATION OF THE LONG-TERM MECHANICAL PERFORMANCE OF CEMENTS FOR VERTEBROPLASTY AND KYPHOPLASTY: CRITICAL REVIEW AND SUGGESTIONS FOR TEST METHODS. J MECH MED BIOL 2018. [DOI: 10.1142/s0219519417300022] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
There is a growing interest towards bone cements for use in vertebroplasty and kyphoplasty, as such spine procedures are becoming more and more common. Such cements feature different compositions, including both traditional acrylic cements and resorbable and bioactive materials. Due to the different compositions and intended use, the mechanical requirements of cements for spinal applications differ from those of traditional cements used in joint replacement. Because of the great clinical implications, it is very important to assess their long-term mechanical competence in terms of fatigue strength and creep. This paper aims at offering a critical overview of the methods currently adopted for such mechanical tests. The existing international standards and guidelines and the literature were searched for publications relevant to fatigue and creep of cements for vertebroplasty and kyphoplasty. While standard methods are available for traditional bone cements in general, no standard indicates specific methods or acceptance criteria for fatigue and creep of cements for vertebroplasty and kyphoplasty. Similarly, a large number of papers were published on cements for joint replacements, but only few cover fatigue and creep of cements for vertebroplasty and kyphoplasty. Furthermore, the literature was analyzed to provide some indications of tests parameters and acceptance criteria (number of cycles, duration in time, stress levels, acceptable amount of creep) for possible tests specifically relevant to cements for spinal applications.
Collapse
Affiliation(s)
- VALENTINA DANESI
- Department of Industrial Engineering, Alma Mater Studiorum — Università di Bologna, Italy
| | - CESARE FALDINI
- Department of Biomedical and Neuromotor Sciences, Alma Mater Studiorum — Università di Bologna, Italy
- Department of Orthopaedics and Trauma Surgery, Università di Bologna — Istituto Ortopedico Rizzoli, Bologna, Italy
| | - LUCA CRISTOFOLINI
- Department of Industrial Engineering, Alma Mater Studiorum — Università di Bologna, Italy
| |
Collapse
|
23
|
Micro Finite Element models of the vertebral body: Validation of local displacement predictions. PLoS One 2017; 12:e0180151. [PMID: 28700618 PMCID: PMC5507408 DOI: 10.1371/journal.pone.0180151] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2017] [Accepted: 06/10/2017] [Indexed: 11/19/2022] Open
Abstract
The estimation of local and structural mechanical properties of bones with micro Finite Element (microFE) models based on Micro Computed Tomography images depends on the quality bone geometry is captured, reconstructed and modelled. The aim of this study was to validate microFE models predictions of local displacements for vertebral bodies and to evaluate the effect of the elastic tissue modulus on model’s predictions of axial forces. Four porcine thoracic vertebrae were axially compressed in situ, in a step-wise fashion and scanned at approximately 39μm resolution in preloaded and loaded conditions. A global digital volume correlation (DVC) approach was used to compute the full-field displacements. Homogeneous, isotropic and linear elastic microFE models were generated with boundary conditions assigned from the interpolated displacement field measured from the DVC. Measured and predicted local displacements were compared for the cortical and trabecular compartments in the middle of the specimens. Models were run with two different tissue moduli defined from microindentation data (12.0GPa) and a back-calculation procedure (4.6GPa). The predicted sum of axial reaction forces was compared to the experimental values for each specimen. MicroFE models predicted more than 87% of the variation in the displacement measurements (R2 = 0.87–0.99). However, model predictions of axial forces were largely overestimated (80–369%) for a tissue modulus of 12.0GPa, whereas differences in the range 10–80% were found for a back-calculated tissue modulus. The specimen with the lowest density showed a large number of elements strained beyond yield and the highest predictive errors. This study shows that the simplest microFE models can accurately predict quantitatively the local displacements and qualitatively the strain distribution within the vertebral body, independently from the considered bone types.
Collapse
|
24
|
Palanca M, Bodey AJ, Giorgi M, Viceconti M, Lacroix D, Cristofolini L, Dall'Ara E. Local displacement and strain uncertainties in different bone types by digital volume correlation of synchrotron microtomograms. J Biomech 2017; 58:27-36. [DOI: 10.1016/j.jbiomech.2017.04.007] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2016] [Revised: 04/01/2017] [Accepted: 04/09/2017] [Indexed: 10/19/2022]
|
25
|
Tozzi G, Dall’Ara E, Palanca M, Curto M, Innocente F, Cristofolini L. Strain uncertainties from two digital volume correlation approaches in prophylactically augmented vertebrae: Local analysis on bone and cement-bone microstructures. J Mech Behav Biomed Mater 2017; 67:117-126. [DOI: 10.1016/j.jmbbm.2016.12.006] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2016] [Revised: 11/02/2016] [Accepted: 12/08/2016] [Indexed: 10/20/2022]
|