1
|
Welzel T, El Shafie RA, V Nettelbladt B, Bernhardt D, Rieken S, Debus J. Stereotactic radiotherapy of brain metastases: clinical impact of three-dimensional SPACE imaging for 3T-MRI-based treatment planning. Strahlenther Onkol 2022; 198:926-933. [PMID: 35976408 PMCID: PMC9515140 DOI: 10.1007/s00066-022-01996-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Accepted: 07/31/2022] [Indexed: 11/30/2022]
Abstract
Purpose For planning CyberKnife stereotactic radiosurgery (CK SRS) of brain metastases (BM), it is essential to precisely determine the exact number and location of BM in MRI. Recent MR studies suggest the superiority of contrast-enhanced 3D fast spin echo SPACE (sampling perfection with application-optimized contrast by using different flip angle evolutions) images over 3D gradient echo (GE) T1-weighted MPRAGE (magnetization-prepared rapid gradient echo) images for detecting small BM. The aim of this study is to test the usability of the SPACE sequence for MRI-based radiation treatment planning and its impact on changing treatment. Methods For MRI-based radiation treatment planning using 3T MRI in 199 patients with cerebral oligometastases, we compared the detectability of BM in post-gadolinium SPACE images, post-gadolinium MPRAGE images, and post-gadolinium late-phase MPRAGE images. Results When SPACE images were used for MRI-based radiation treatment planning, 29.8% and 16.9% more BM, respectively, were detected and included in treatment planning than in the post-gadolinium MPRAGE images and the post-gadolinium late-phase MPRAGE images (post-gadolinium MPRAGE imaging: ntotal = 681, mean ± SD 3.4 ± 4.2; post-gadolinium SPACE imaging: ntotal = 884, mean ± SD 4.4 ± 6.0; post-gadolinium late-phase MPRAGE imaging: ntotal = 796, mean ± SD 4.0 ± 5.3; Ppost-gadolinium SPACE imaging versus post-gadolinium MPRAGE imaging < 0.0001, Ppost-gadolinium SPACE imaging versus post-gadolinium late-phase MPRAGE imaging< 0.0001). Conclusion For 3T MRI-based treatment planning of stereotactic radiosurgery of BM, we recommend the use of post-gadolinium SPACE imaging rather than post-gadolinium MPRAGE imaging.
Collapse
Affiliation(s)
- Thomas Welzel
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany. .,Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany. .,National Center for Tumor diseases (NCT), Heidelberg, Germany.
| | - Rami A El Shafie
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany.,Department of Radiation Oncology, University Medical Center Göttingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany
| | - Bastian V Nettelbladt
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany.,National Center for Tumor diseases (NCT), Heidelberg, Germany
| | - Denise Bernhardt
- Department of Radiation Oncology, Klinikum rechts der Isar, Technical University Munich, Ismaninger Str. 22, 81675, Munich, Germany
| | - Stefan Rieken
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany.,Department of Radiation Oncology, University Medical Center Göttingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany
| | - Jürgen Debus
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany.,National Center for Tumor diseases (NCT), Heidelberg, Germany.,German Cancer Consortium (DKTK), Partner site Heidelberg, German Cancer Research Center (DKFZ), Heidelberg, Germany
| |
Collapse
|
2
|
Mitchell D, Kwon HJ, Kubica PA, Huff WX, O’Regan R, Dey M. Brain metastases: An update on the multi-disciplinary approach of clinical management. Neurochirurgie 2022; 68:69-85. [PMID: 33864773 PMCID: PMC8514593 DOI: 10.1016/j.neuchi.2021.04.001] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Revised: 03/16/2021] [Accepted: 04/03/2021] [Indexed: 01/03/2023]
Abstract
IMPORTANCE Brain metastasis (BM) is the most common malignant intracranial neoplasm in adults with over 100,000 new cases annually in the United States and outnumbering primary brain tumors 10:1. OBSERVATIONS The incidence of BM in adult cancer patients ranges from 10-40%, and is increasing with improved surveillance, effective systemic therapy, and an aging population. The overall prognosis of cancer patients is largely dependent on the presence or absence of brain metastasis, and therefore, a timely and accurate diagnosis is crucial for improving long-term outcomes, especially in the current era of significantly improved systemic therapy for many common cancers. BM should be suspected in any cancer patient who develops new neurological deficits or behavioral abnormalities. Gadolinium enhanced MRI is the preferred imaging technique and BM must be distinguished from other pathologies. Large, symptomatic lesion(s) in patients with good functional status are best treated with surgery and stereotactic radiosurgery (SRS). Due to neurocognitive side effects and improved overall survival of cancer patients, whole brain radiotherapy (WBRT) is reserved as salvage therapy for patients with multiple lesions or as palliation. Newer approaches including multi-lesion stereotactic surgery, targeted therapy, and immunotherapy are also being investigated to improve outcomes while preserving quality of life. CONCLUSION With the significant advancements in the systemic treatment for cancer patients, addressing BM effectively is critical for overall survival. In addition to patient's performance status, therapeutic approach should be based on the type of primary tumor and associated molecular profile as well as the size, number, and location of metastatic lesion(s).
Collapse
Affiliation(s)
- D Mitchell
- Department of Neurosurgery, Indiana University School of Medicine, Indiana University Purdue University Indianapolis, IN, USA
| | - HJ Kwon
- Department of Neurosurgery, Indiana University School of Medicine, Indiana University Purdue University Indianapolis, IN, USA
| | - PA Kubica
- Department of Neurosurgery, University of Wisconsin School of Medicine & Public Health, UW Carbone Cancer Center, Madison, WI, USA
| | - WX Huff
- Department of Neurosurgery, Indiana University School of Medicine, Indiana University Purdue University Indianapolis, IN, USA
| | - R O’Regan
- Department of Medicine/Hematology Oncology, University of Wisconsin School of Medicine & Public Health, UW Carbone Cancer Center, Madison, WI, USA
| | - M Dey
- Department of Neurosurgery, University of Wisconsin School of Medicine & Public Health, UW Carbone Cancer Center, Madison, WI, USA,Correspondence Should Be Addressed To: Mahua Dey, MD, University of Wisconsin School of Medicine & Public Health, 600 Highland Ave, Madison, WI 53792; Tel: 317-274-2601;
| |
Collapse
|
3
|
Yuan J, Law SCK, Wong KK, Lo GG, Kam MKM, Kwan WH, Xue C, Wong OL, Yu SK, Cheung KY. 3D T1-weighted turbo spin echo contrast-enhanced MRI at 1.5 T for frameless brain metastases radiotherapy. J Cancer Res Clin Oncol 2021; 148:1749-1759. [PMID: 34363123 DOI: 10.1007/s00432-021-03755-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Accepted: 07/31/2021] [Indexed: 11/27/2022]
Abstract
PURPOSE Performance of 3D-T1W-TSE has been proven superior to 3D-MP-GRE at 3 T on brain metastases (BM) contrast-enhanced (CE) MRI. However, its performance at 1.5 T is largely unknown and sparsely reported. This study aims to assess image quality, lesion detectability and conspicuity of 1.5 T 3D-T1W-TSE on planning MRI of frameless BM radiotherapy. METHODS 94 BM patients to be treated by frameless brain radiotherapy were scanned using 3D-T1W-TSE with immobilization on multi-vendor 1.5 T MRI-simulators. BMs were jointly diagnosed by 4 reviewers. Enhanced lesion conspicuity was quantitatively assessed by calculating contrast ratio (CR) and contrast-to-noise ratio (CNR). Signal-to-noise ratio (SNR) reduction of white matter due to the use of flexible coil was assessed. Lesion detectability and conspicuity were compared between 1.5 T planning MRI and 3 T diagnostic MRI by an oncologist and a radiologist in 10 patients. RESULTS 497 BMs were jointly diagnosed. The CR and CNR were 75.2 ± 39.9% and 14.2 ± 8.1, respectively. SNR reduced considerably from 31.7 ± 8.3 to 21.9 ± 5.4 with the longer distance to coils. 3 T diagnostic MRI and 1.5 T planning MRI yielded exactly the same detection of 84 BMs. Qualitatively, lesion conspicuity at 1.5 T was not inferior to that at 3 T. Quantitatively, lower brain SNR and lesion CNR were found at 1.5 T, while lesion CR at 1.5 T was highly comparable to that at 3 T. CONCLUSION 1.5 T 3D-T1W-TSE planning MRI of frameless BM radiotherapy was comprehensively assessed. Highly comparable BM detectability and conspicuity were achieved by 1.5 T planning MRI compared to 3 T diagnostic MRI. 1.5 T 3D-T1W-TSE should be valuable for frameless brain radiotherapy planning.
Collapse
Affiliation(s)
- Jing Yuan
- Medical Physics and Research Department, Hong Kong Sanatorium and Hospital, 8/F, Li Shu Fan Block, 2 Village Road, Happy Valley, Hong Kong SAR, China.
| | - Stephen C K Law
- Comprehensive Oncology Centre, Hong Kong Sanatorium and Hospital, Happy Valley, Hong Kong SAR, China
| | - Ka Kin Wong
- Department of Diagnostic and Interventional Radiology, Hong Kong Sanatorium and Hospital, Happy Valley, Hong Kong SAR, China
| | - Gladys G Lo
- Department of Diagnostic and Interventional Radiology, Hong Kong Sanatorium and Hospital, Happy Valley, Hong Kong SAR, China
| | - Michael K M Kam
- Comprehensive Oncology Centre, Hong Kong Sanatorium and Hospital, Happy Valley, Hong Kong SAR, China
| | - Wing Hong Kwan
- Comprehensive Oncology Centre, Hong Kong Sanatorium and Hospital, Happy Valley, Hong Kong SAR, China
| | - Cindy Xue
- Medical Physics and Research Department, Hong Kong Sanatorium and Hospital, 8/F, Li Shu Fan Block, 2 Village Road, Happy Valley, Hong Kong SAR, China
| | - Oi Lei Wong
- Medical Physics and Research Department, Hong Kong Sanatorium and Hospital, 8/F, Li Shu Fan Block, 2 Village Road, Happy Valley, Hong Kong SAR, China
| | - Siu Ki Yu
- Medical Physics and Research Department, Hong Kong Sanatorium and Hospital, 8/F, Li Shu Fan Block, 2 Village Road, Happy Valley, Hong Kong SAR, China
| | - Kin Yin Cheung
- Medical Physics and Research Department, Hong Kong Sanatorium and Hospital, 8/F, Li Shu Fan Block, 2 Village Road, Happy Valley, Hong Kong SAR, China
| |
Collapse
|
4
|
Kim D, Heo YJ, Jeong HW, Baek JW, Han JY, Lee JY, Jin SC, Baek HJ. Usefulness of the Delay Alternating with Nutation for Tailored Excitation Pulse with T1-Weighted Sampling Perfection with Application-Optimized Contrasts Using Different Flip Angle Evolution in the Detection of Cerebral Metastases: Comparison with MPRAGE Imaging. AJNR Am J Neuroradiol 2019; 40:1469-1475. [PMID: 31371358 DOI: 10.3174/ajnr.a6158] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2019] [Accepted: 06/27/2019] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Contrast-enhanced T1-weighted sampling perfection with application-optimized contrasts by using different flip angle evolution (SPACE) with the delay alternating with nutation for tailored excitation (DANTE) pulse could suppress the blood flow signal and provide a higher contrast-to-noise ratio of enhancing lesion-to-brain parenchyma than the MPRAGE sequence. The purpose of our study was to evaluate the usefulness of SPACE with DANTE compared with MPRAGE for detecting brain metastases. MATERIALS AND METHODS Seventy-one patients who underwent contrast-enhanced SPACE with DANTE and MPRAGE sequences and who were suspected of having metastatic lesions were included. Two neuroradiologists determined the number of enhancing lesions, and diagnostic performance was evaluated using figure of merit, sensitivity, positive predictive value, interobserver agreement, and reading time. Contrast-to-noise ratiolesion/parenchyma and contrast-to-noise ratiowhite matter/gray matter were also assessed. RESULTS SPACE with DANTE (observer one, 328; observer two, 324) revealed significantly more small (<5 mm) enhancing lesions than MPRAGE (observer one, 175; observer two, 150) (P < 0.001 for observer 1, P ≤ .0001 for observer 2). Furthermore, SPACE with DANTE showed significantly higher figure of merit and sensitivity and shorter reading time than MPRAGE for both observers. The mean contrast-to-noise ratiolesion/parenchyma of SPACE with DANTE (52.3 ± 43.1) was significantly higher than that of MPRAGE (17.5 ± 19.3) (P ≤ .0001), but the mean contrast-to-noise ratiowhite matter/gray matter of SPACE with DANTE (-0.65 ± 1.39) was significantly lower than that of MPRAGE (3.08 ± 1.39) (P ≤ .0001). CONCLUSIONS Compared with MPRAGE, SPACE with DANTE significantly improves the detection of brain metastases.
Collapse
Affiliation(s)
- D Kim
- From the Departments of Radiology (D.K., Y.J.H., H.W.J., J.W.B., J.-Y.H.)
| | - Y J Heo
- From the Departments of Radiology (D.K., Y.J.H., H.W.J., J.W.B., J.-Y.H.)
| | - H W Jeong
- From the Departments of Radiology (D.K., Y.J.H., H.W.J., J.W.B., J.-Y.H.)
| | - J W Baek
- From the Departments of Radiology (D.K., Y.J.H., H.W.J., J.W.B., J.-Y.H.)
| | - J-Y Han
- From the Departments of Radiology (D.K., Y.J.H., H.W.J., J.W.B., J.-Y.H.)
| | - J Y Lee
- Internal Medicine (J.Y.L.), Inje University Busan Paik Hospital, Busan, Korea
| | - S-C Jin
- Department of Neurosurgery (S.-C.J.), Inje University Haeundae Paik Hospital, Busan, Republic of Korea
| | - H J Baek
- Department of Radiology (H.J.B.), Gyeongsang National University School of Medicine and Gyeongsang National University Changwon Hospital, Changwon, Republic of Korea
| |
Collapse
|
5
|
CNS Involvement in Non-CNS Tumors. Clin Neuroradiol 2019. [DOI: 10.1007/978-3-319-61423-6_61-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
6
|
CNS Involvement in Non-CNS Tumors. Clin Neuroradiol 2019. [DOI: 10.1007/978-3-319-68536-6_61] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
7
|
Geometric distortion in magnetic resonance imaging systems assessed using an open-source plugin for scientific image analysis. Radiol Phys Technol 2018; 11:467-472. [PMID: 30255438 DOI: 10.1007/s12194-018-0477-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2018] [Revised: 09/18/2018] [Accepted: 09/18/2018] [Indexed: 10/28/2022]
Abstract
Tumor locations are commonly delineated by referring to magnetic resonance (MR) images. However, MR images have geometric distortions that cannot be completely corrected. This study aimed to investigate quantitatively uncorrectable error [residual error (RE)] with the use of an open-source plugin for scientific image analysis. The RE values were calculated by Fiji, which was enhanced by Image J image processing software. The results obtained with the open-source plugin for scientific image analysis agreed with the results obtained with the commercially available software. Obtaining detailed geometric distortion data for each facility and device could facilitate safe treatment because the homogeneous magnetic field in MR imaging varies across devices and over time. Therefore, using an open-source plugin for scientific image analysis may be an accurate and effective technique for evaluating the RE of MR imaging systems.
Collapse
|
8
|
Yoon BC, Saad AF, Rezaii P, Wintermark M, Zaharchuk G, Iv M. Evaluation of Thick-Slab Overlapping MIP Images of Contrast-Enhanced 3D T1-Weighted CUBE for Detection of Intracranial Metastases: A Pilot Study for Comparison of Lesion Detection, Interpretation Time, and Sensitivity with Nonoverlapping CUBE MIP, CUBE, and Inversion-Recovery-Prepared Fast-Spoiled Gradient Recalled Brain Volume. AJNR Am J Neuroradiol 2018; 39:1635-1642. [PMID: 30093483 DOI: 10.3174/ajnr.a5747] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2017] [Accepted: 06/16/2018] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Early and accurate identification of cerebral metastases is important for prognostication and treatment planning although this process is often time consuming and labor intensive, especially with the hundreds of images associated with 3D volumetric imaging. This study aimed to evaluate the benefits of thick-slab overlapping MIPs constructed from contrast-enhanced T1-weighted CUBE (overlapping CUBE MIP) for the detection of brain metastases in comparison with traditional CUBE and inversion-recovery prepared fast-spoiled gradient recalled brain volume (IR-FSPGR-BRAVO) and nonoverlapping CUBE MIP. MATERIALS AND METHODS A retrospective review of 48 patients with cerebral metastases was performed at our institution from June 2016 to October 2017. Brain MRIs, which were acquired on multiple 3T scanners, included gadolinium-enhanced T1-weighted IR-FSPGR-BRAVO and CUBE, with subsequent generation of nonoverlapping CUBE MIP and overlapping CUBE MIP. Two blinded radiologists identified the total number and location of metastases on each image type. The Cohen κ was used to determine interrater agreement. Sensitivity, interpretation time, and lesion contrast-to-noise ratio were assessed. RESULTS Interrater agreement for identification of metastases was fair-to-moderate for all image types (κ = 0.222-0.598). The total number of metastases identified was not significantly different across the image types. Interpretation time for CUBE MIPs was significantly shorter than for CUBE and IR-FSPGR-BRAVO, saving at least 50 seconds per case on average (P < .001). The mean lesion contrast-to-noise ratio for both CUBE MIPs was higher than for IR-FSPGR-BRAVO. The mean contrast-to-noise ratio for small lesions (<4 mm) was lower for nonoverlapping CUBE MIP (1.55) than for overlapping CUBE MIP (2.35). For both readers, the sensitivity for lesion detection was high for all image types but highest for overlapping CUBE MIP and CUBE (0.93-0.97). CONCLUSIONS This study suggests that the use of overlapping CUBE MIP or nonoverlapping CUBE MIP for the detection of brain metastases can reduce interpretation time without sacrificing sensitivity, though the contrast-to-noise ratio of lesions is highest for overlapping CUBE MIP.
Collapse
Affiliation(s)
- B C Yoon
- From the Department of Radiology, Division of Neuroimaging and Neurointervention, Stanford University, Stanford, California
| | - A F Saad
- From the Department of Radiology, Division of Neuroimaging and Neurointervention, Stanford University, Stanford, California
| | - P Rezaii
- From the Department of Radiology, Division of Neuroimaging and Neurointervention, Stanford University, Stanford, California
| | - M Wintermark
- From the Department of Radiology, Division of Neuroimaging and Neurointervention, Stanford University, Stanford, California
| | - G Zaharchuk
- From the Department of Radiology, Division of Neuroimaging and Neurointervention, Stanford University, Stanford, California
| | - M Iv
- From the Department of Radiology, Division of Neuroimaging and Neurointervention, Stanford University, Stanford, California.
| |
Collapse
|
9
|
Thust SC, van den Bent MJ, Smits M. Pseudoprogression of brain tumors. J Magn Reson Imaging 2018; 48:571-589. [PMID: 29734497 PMCID: PMC6175399 DOI: 10.1002/jmri.26171] [Citation(s) in RCA: 168] [Impact Index Per Article: 28.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2018] [Accepted: 04/07/2018] [Indexed: 12/11/2022] Open
Abstract
This review describes the definition, incidence, clinical implications, and magnetic resonance imaging (MRI) findings of pseudoprogression of brain tumors, in particular, but not limited to, high-grade glioma. Pseudoprogression is an important clinical problem after brain tumor treatment, interfering not only with day-to-day patient care but also the execution and interpretation of clinical trials. Radiologically, pseudoprogression is defined as a new or enlarging area(s) of contrast agent enhancement, in the absence of true tumor growth, which subsides or stabilizes without a change in therapy. The clinical definitions of pseudoprogression have been quite variable, which may explain some of the differences in reported incidences, which range from 9-30%. Conventional structural MRI is insufficient for distinguishing pseudoprogression from true progressive disease, and advanced imaging is needed to obtain higher levels of diagnostic certainty. Perfusion MRI is the most widely used imaging technique to diagnose pseudoprogression and has high reported diagnostic accuracy. Diagnostic performance of MR spectroscopy (MRS) appears to be somewhat higher, but MRS is less suitable for the routine and universal application in brain tumor follow-up. The combination of MRS and diffusion-weighted imaging and/or perfusion MRI seems to be particularly powerful, with diagnostic accuracy reaching up to or even greater than 90%. While diagnostic performance can be high with appropriate implementation and interpretation, even a combination of techniques, however, does not provide 100% accuracy. It should also be noted that most studies to date are small, heterogeneous, and retrospective in nature. Future improvements in diagnostic accuracy can be expected with harmonization of acquisition and postprocessing, quantitative MRI and computer-aided diagnostic technology, and meticulous evaluation with clinical and pathological data. LEVEL OF EVIDENCE 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018.
Collapse
Affiliation(s)
- Stefanie C. Thust
- Lysholm Neuroradiology DepartmentNational Hospital for Neurology and NeurosurgeryLondonUK
- Department of Brain Rehabilitation and RepairUCL Institute of NeurologyLondonUK
- Imaging DepartmentUniversity College London HospitalLondonUK
| | - Martin J. van den Bent
- Department of NeurologyThe Brain Tumor Centre at Erasmus MC Cancer InstituteRotterdamThe Netherlands
| | - Marion Smits
- Department of Radiology and Nuclear Medicine, Erasmus MCUniversity Medical Centre RotterdamRotterdamThe Netherlands
| |
Collapse
|
10
|
Deike-Hofmann K, Thünemann D, Breckwoldt MO, Schwarz D, Radbruch A, Enk A, Bendszus M, Hassel J, Schlemmer HP, Bäumer P. Sensitivity of different MRI sequences in the early detection of melanoma brain metastases. PLoS One 2018; 13:e0193946. [PMID: 29596475 PMCID: PMC5875773 DOI: 10.1371/journal.pone.0193946] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2017] [Accepted: 02/21/2018] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND After the emergence of new MRI techniques such as susceptibility- and diffusion-weighted imaging (SWI and DWI) and because of specific imaging characteristics of melanoma brain metastases (MBM), it is unclear which MRI sequences are most beneficial for detection of MBM. This study was performed to investigate the sensitivity of six clinical MRI sequences in the early detection of MBM. METHODS Medical records of all melanoma patients referred to our center between November 2005 and December 2016 were reviewed for presence of MBM. Analysis encompassed six MRI sequences at the time of initial diagnosis of first or new MBM, including non-enhanced T1-weighted (T1w), contrast-enhanced T1w (ceT1w), T2-weighted (T2w), T2w-FLAIR, susceptibility-weighted (SWI) and diffusion-weighted (DWI) MRI. Each lesion was rated with respect to its conspicuity (score from 0-not detectable to 3-clearly visible). RESULTS Of 1210 patients, 217 with MBM were included in the analysis and up to 5 lesions per patient were evaluated. A total of 720 metastases were assessed and all six sequences were available for 425 MBM. Sensitivity (conspicuity ≥2) was 99.7% for ceT1w, 77.0% for FLAIR, 64.7% for SWI, 61.0% for T2w, 56.7% for T1w, and 48.4% for DWI. Thirty-one (7.3%) of 425 lesions were only detectable by ceT1w but no other sequence. CONCLUSIONS Contrast-enhanced T1-weighting is more sensitive than all other sequences for detection of MBM. Disruption of the blood-brain-barrier is consistently an earlier sign in MBM than perifocal edema, signal loss on SWI or diffusion restriction.
Collapse
Affiliation(s)
| | - Daniel Thünemann
- Department of Radiology, German Cancer Research Center, DKFZ, Heidelberg, Germany
| | - Michael O. Breckwoldt
- Department of Radiology, German Cancer Research Center, DKFZ, Heidelberg, Germany
- Department of Neuroradiology, University of Heidelberg Medical Center, Heidelberg, Germany
| | - Daniel Schwarz
- Department of Radiology, German Cancer Research Center, DKFZ, Heidelberg, Germany
- Department of Neuroradiology, University of Heidelberg Medical Center, Heidelberg, Germany
| | - Alexander Radbruch
- Department of Radiology, German Cancer Research Center, DKFZ, Heidelberg, Germany
| | - Alexander Enk
- Department of Dermatology, National Center for Tumor Diseases, NCT, University of Heidelberg Medical Center Heidelberg, Germany
| | - Martin Bendszus
- Department of Neuroradiology, University of Heidelberg Medical Center, Heidelberg, Germany
| | - Jessica Hassel
- Department of Dermatology, National Center for Tumor Diseases, NCT, University of Heidelberg Medical Center Heidelberg, Germany
| | | | - Philipp Bäumer
- Department of Radiology, German Cancer Research Center, DKFZ, Heidelberg, Germany
- * E-mail:
| |
Collapse
|
11
|
Thust SC, Heiland S, Falini A, Jäger HR, Waldman AD, Sundgren PC, Godi C, Katsaros VK, Ramos A, Bargallo N, Vernooij MW, Yousry T, Bendszus M, Smits M. Glioma imaging in Europe: A survey of 220 centres and recommendations for best clinical practice. Eur Radiol 2018. [PMID: 29536240 PMCID: PMC6028837 DOI: 10.1007/s00330-018-5314-5] [Citation(s) in RCA: 129] [Impact Index Per Article: 21.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Objectives At a European Society of Neuroradiology (ESNR) Annual Meeting 2015 workshop, commonalities in practice, current controversies and technical hurdles in glioma MRI were discussed. We aimed to formulate guidance on MRI of glioma and determine its feasibility, by seeking information on glioma imaging practices from the European Neuroradiology community. Methods Invitations to a structured survey were emailed to ESNR members (n=1,662) and associates (n=6,400), European national radiologists’ societies and distributed via social media. Results Responses were received from 220 institutions (59% academic). Conventional imaging protocols generally include T2w, T2-FLAIR, DWI, and pre- and post-contrast T1w. Perfusion MRI is used widely (85.5%), while spectroscopy seems reserved for specific indications. Reasons for omitting advanced imaging modalities include lack of facility/software, time constraints and no requests. Early postoperative MRI is routinely carried out by 74% within 24–72 h, but only 17% report a percent measure of resection. For follow-up, most sites (60%) issue qualitative reports, while 27% report an assessment according to the RANO criteria. A minority of sites use a reporting template (23%). Conclusion Clinical best practice recommendations for glioma imaging assessment are proposed and the current role of advanced MRI modalities in routine use is addressed. Key Points • We recommend the EORTC-NBTS protocol as the clinical standard glioma protocol. • Perfusion MRI is recommended for diagnosis and follow-up of glioma. • Use of advanced imaging could be promoted with increased education activities. • Most response assessment is currently performed qualitatively. • Reporting templates are not widely used, and could facilitate standardisation. Electronic supplementary material The online version of this article (10.1007/s00330-018-5314-5) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- S C Thust
- Lysholm Neuroradiology Department, National Hospital for Neurology and Neurosurgery, London, UK
- Department of Brain Rehabilitation and Repair, UCL Institute of Neurology, London, UK
- Imaging Department, University College London Hospital, London, UK
| | - S Heiland
- Department of Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany
| | - A Falini
- Department of Neuroradiology, San Raffaele Scientific Institute, Milan, Italy
| | - H R Jäger
- Lysholm Neuroradiology Department, National Hospital for Neurology and Neurosurgery, London, UK
- Department of Brain Rehabilitation and Repair, UCL Institute of Neurology, London, UK
- Imaging Department, University College London Hospital, London, UK
| | - A D Waldman
- Neuroimaging Sciences, University of Edinburgh, Edinburgh, UK
| | - P C Sundgren
- Institution for Clinical Sciences/Radiology, Lund University, Lund, Sweden
- Centre for Imaging and Physiology, Skåne University hospital, Lund, Sweden
| | - C Godi
- Department of Neuroradiology, San Raffaele Scientific Institute, Milan, Italy
| | - V K Katsaros
- General Anti-Cancer and Oncological Hospital "Agios Savvas", Athens, Greece
- Central Clinic of Athens, Athens, Greece
- University of Athens, Athens, Greece
| | - A Ramos
- Hospital 12 de Octubre, Madrid, Spain
| | - N Bargallo
- Image Diagnostic Centre, Hospital Clinic de Barcelona, Barcelona, Spain
- Magnetic Resonance Core Facility, Institut per la Recerca Biomedica August Pi i Sunyer (IDIBAPS), Barcelona, Spain
| | - M W Vernooij
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
- Department of Epidemiology, Erasmus MC, Rotterdam, The Netherlands
| | - T Yousry
- Lysholm Neuroradiology Department, National Hospital for Neurology and Neurosurgery, London, UK
| | - M Bendszus
- Department of Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany
| | - M Smits
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands.
| |
Collapse
|
12
|
Abstract
Magnetic resonance imaging (MRI) is the cornerstone for evaluating patients with brain masses such as primary and metastatic tumors. Important challenges in effectively detecting and diagnosing brain metastases and in accurately characterizing their subsequent response to treatment remain. These difficulties include discriminating metastases from potential mimics such as primary brain tumors and infection, detecting small metastases, and differentiating treatment response from tumor recurrence and progression. Optimal patient management could be benefited by improved and well-validated prognostic and predictive imaging markers, as well as early response markers to identify successful treatment prior to changes in tumor size. To address these fundamental needs, newer MRI techniques including diffusion and perfusion imaging, MR spectroscopy, and positron emission tomography (PET) tracers beyond traditionally used 18-fluorodeoxyglucose are the subject of extensive ongoing investigations, with several promising avenues of added value already identified. These newer techniques provide a wealth of physiologic and metabolic information that may supplement standard MR evaluation, by providing the ability to monitor and characterize cellularity, angiogenesis, perfusion, pH, hypoxia, metabolite concentrations, and other critical features of malignancy. This chapter reviews standard and advanced imaging of brain metastases provided by computed tomography, MRI, and amino acid PET, focusing on potential biomarkers that can serve as problem-solving tools in the clinical management of patients with brain metastases.
Collapse
Affiliation(s)
- Whitney B Pope
- Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, CA, United States.
| |
Collapse
|
13
|
Thaler C, Schneider T, Sedlacik J, Kutzner D, Stellmann JP, Heesen C, Fiehler J, Siemonsen S. T1w dark blood imaging improves detection of contrast enhancing lesions in multiple sclerosis. PLoS One 2017; 12:e0183099. [PMID: 28797082 PMCID: PMC5552307 DOI: 10.1371/journal.pone.0183099] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2017] [Accepted: 07/29/2017] [Indexed: 11/18/2022] Open
Abstract
PURPOSE In multiple sclerosis (MS) the sensitivity for detection of contrast enhancing lesions (CEL) in T1-weighted scans is essential for diagnostics and therapy decisions. The purpose of our study was to evaluate the sensitivity of T1w MPRAGE scans in comparison to T1w dark blood technique (T1-DB) for CEL in MS. MATERIALS AND METHODS 3T MR imaging was performed in 37 MS patients, including T2-weighted imaging, T1w MPRAGE before and after gadolinium injection (unenhanced-T1 and T1-CE) and T1-DB imaging. After gadolinium application, the T1-DB scan was performed prior to T1-CE. From unenhanced-T1 and T1-CE scans, subtraction images (T1-SUB) were calculated. The number of CEL was determined separately on T1-CE and T1-DB by two raters independently. Lesions only detected on T1-DB scans then were verified on T1-SUB. Only lesions detected by both raters were included in further analysis. RESULTS In 16 patients, at least one CEL was detected by both rater, either on T1-CE or T1-DB. All lesions that were detected on T1-CE were also detected on T1-DB images. The total number of contrast enhancing lesions detected on T1-DB images (n = 54) by both raters was significantly higher than the corresponding number of lesions identified on T1-CE (n = 27) (p = 0.01); all of these lesions could be verified on SUB images. In 21 patients, no CEL was detected in any of the sequences. CONCLUSIONS The application of T1-DB technique increases the sensitivity for CEL in MS, especially for those lesions that show only subtle increase in intensity after Gadolinium application but remain hypo- or iso-intense to surrounding tissue.
Collapse
Affiliation(s)
- Christian Thaler
- Department of Diagnostic and Interventional Neuroradiology, University Medical Centre Hamburg-Eppendorf, Hamburg, Germany
- * E-mail:
| | - Tanja Schneider
- Department of Diagnostic and Interventional Neuroradiology, University Medical Centre Hamburg-Eppendorf, Hamburg, Germany
| | - Jan Sedlacik
- Department of Diagnostic and Interventional Neuroradiology, University Medical Centre Hamburg-Eppendorf, Hamburg, Germany
| | - Daniel Kutzner
- Department of Diagnostic and Interventional Neuroradiology, University Medical Centre Hamburg-Eppendorf, Hamburg, Germany
| | - Jan-Patrick Stellmann
- Department of Neurology, University Medical Centre Hamburg-Eppendorf, Hamburg, Germany
- Institute for Neuroimmunology and Clinical MS Research, University Medical Centre Hamburg-Eppendorf, Hamburg, Germany
| | - Christoph Heesen
- Department of Neurology, University Medical Centre Hamburg-Eppendorf, Hamburg, Germany
- Institute for Neuroimmunology and Clinical MS Research, University Medical Centre Hamburg-Eppendorf, Hamburg, Germany
| | - Jens Fiehler
- Department of Diagnostic and Interventional Neuroradiology, University Medical Centre Hamburg-Eppendorf, Hamburg, Germany
| | - Susanne Siemonsen
- Department of Diagnostic and Interventional Neuroradiology, University Medical Centre Hamburg-Eppendorf, Hamburg, Germany
| |
Collapse
|
14
|
Bae YJ, Choi BS, Lee KM, Yoon YH, Sunwoo L, Jung C, Kim JH. Efficacy of Maximum Intensity Projection of Contrast-Enhanced 3D Turbo-Spin Echo Imaging with Improved Motion-Sensitized Driven-Equilibrium Preparation in the Detection of Brain Metastases. Korean J Radiol 2017; 18:699-709. [PMID: 28670165 PMCID: PMC5447646 DOI: 10.3348/kjr.2017.18.4.699] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2016] [Accepted: 01/16/2017] [Indexed: 11/15/2022] Open
Abstract
Objective To evaluate the diagnostic benefits of 5-mm maximum intensity projection of improved motion-sensitized driven-equilibrium prepared contrast-enhanced 3D T1-weighted turbo-spin echo imaging (MIP iMSDE-TSE) in the detection of brain metastases. The imaging technique was compared with 1-mm images of iMSDE-TSE (non-MIP iMSDE-TSE), 1-mm contrast-enhanced 3D T1-weighted gradient-echo imaging (non-MIP 3D-GRE), and 5-mm MIP 3D-GRE. Materials and Methods From October 2014 to July 2015, 30 patients with 460 enhancing brain metastases (size > 3 mm, n = 150; size ≤ 3 mm, n = 310) were scanned with non-MIP iMSDE-TSE and non-MIP 3D-GRE. We then performed 5-mm MIP reconstruction of these images. Two independent neuroradiologists reviewed these four sequences. Their diagnostic performance was compared using the following parameters: sensitivity, reading time, and figure of merit (FOM) derived by jackknife alternative free-response receiver operating characteristic analysis. Interobserver agreement was also tested. Results The mean FOM (all lesions, 0.984; lesions ≤ 3 mm, 0.980) and sensitivity ([reader 1: all lesions, 97.3%; lesions ≤ 3 mm, 96.2%], [reader 2: all lesions, 97.0%; lesions ≤ 3 mm, 95.8%]) of MIP iMSDE-TSE was comparable to the mean FOM (0.985, 0.977) and sensitivity ([reader 1: 96.7, 99.0%], [reader 2: 97, 95.3%]) of non-MIP iMSDE-TSE, but they were superior to those of non-MIP and MIP 3D-GREs (all, p < 0.001). The reading time of MIP iMSDE-TSE (reader 1: 47.7 ± 35.9 seconds; reader 2: 44.7 ± 23.6 seconds) was significantly shorter than that of non-MIP iMSDE-TSE (reader 1: 78.8 ± 43.7 seconds, p = 0.01; reader 2: 82.9 ± 39.9 seconds, p < 0.001). Interobserver agreement was excellent (κ > 0.75) for all lesions in both sequences. Conclusion MIP iMSDE-TSE showed high detectability of brain metastases. Its detectability was comparable to that of non-MIP iMSDE-TSE, but it was superior to the detectability of non-MIP/MIP 3D-GREs. With a shorter reading time, the false-positive results of MIP iMSDE-TSE were greater. We suggest that MIP iMSDE-TSE can provide high diagnostic performance and low false-positive rates when combined with 1-mm sequences.
Collapse
Affiliation(s)
- Yun Jung Bae
- Department of Radiology, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam 13620, Korea
| | - Byung Se Choi
- Department of Radiology, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam 13620, Korea
| | - Kyung Mi Lee
- Department of Radiology, Kyung Hee University College of Medicine, Kyung Hee University Hospital, Seoul 02447, Korea
| | - Yeon Hong Yoon
- Department of Radiology, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam 13620, Korea
| | - Leonard Sunwoo
- Department of Radiology, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam 13620, Korea
| | - Cheolkyu Jung
- Department of Radiology, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam 13620, Korea
| | - Jae Hyoung Kim
- Department of Radiology, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam 13620, Korea
| |
Collapse
|
15
|
Kammer NN, Coppenrath E, Treitl KM, Kooijman H, Dietrich O, Saam T. Comparison of contrast-enhanced modified T1-weighted 3D TSE black-blood and 3D MP-RAGE sequences for the detection of cerebral metastases and brain tumours. Eur Radiol 2015; 26:1818-25. [PMID: 26334511 DOI: 10.1007/s00330-015-3975-x] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2015] [Revised: 07/24/2015] [Accepted: 08/07/2015] [Indexed: 10/23/2022]
Abstract
OBJECTIVES To compare a modified T1-weighted 3D TSE black-blood sequence with sub-millimetre resolution (T1-mVISTA) with a magnetization-prepared rapid gradient echo (MP-RAGE) sequence for the diagnosis of cerebral malignomas. METHODS Forty-six patients with known or suspected intracranial tumours and 15 control patients were included in this retrospective study. All patients underwent T1-mVISTA (0.75-mm isotropic resolution, 4:43 min) and MP-RAGE (0.8-mm isotropic resolution, 4:46 minutes) at 3-Tesla in random order after application of contrast agent. Two experienced radiologists determined the number of lesions. Maximum diameter, diagnostic confidence (DC), visual assessment of contrast enhancement (VCE) and CNRlesion/parenchyma were assessed for each lesion. RESULTS Significantly more lesions were detected with T1-mVISTA compared to the MP-RAGE (61 vs. 36; p < 0.05). Further, DC and VCE was rated significantly higher in the T1-mVISTA (p < 0.05 and p < 0.001). Mean CNRlesion/parenchyma was twofold higher for T1-mVISTA (24.2 ± 17.5 vs. 12.7 ± 11.5, p < 0.001). The 25 lesions detected only in T1-mVISTA were significantly smaller than those detected in both sequences (4.3 ± 3.7 mm vs. 11.3 ± 10.7 mm; p < 0.01). CONCLUSIONS T1-mVISTA increases the contrast of lesions significantly compared to MP-RAGE and might therefore improve detection rates of small lesions in early stages of disease. KEY POINTS • T1-mVISTA leads to significantly higher contrast-to-noise ratios of cerebral malignomas. • T1-mVISTA detects significantly more metastatic lesions compared to 3D-MPRAGE. • Lesions detected only by T1-mVISTA are smaller than those detected in both sequences. • Diagnostic confidence is significantly higher for lesions detected by T1-mVISTA. • Application of T1-mVISTA might be of high relevance in early stages of disease.
Collapse
Affiliation(s)
- N N Kammer
- Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, Nussbaumstr. 20, 80336, Munich, Germany.
| | - E Coppenrath
- Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, Nussbaumstr. 20, 80336, Munich, Germany
| | - K M Treitl
- Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, Nussbaumstr. 20, 80336, Munich, Germany
| | - H Kooijman
- Philips Healthcare, Luebeckertordamm 5, 20099, Hamburg, Germany
| | - O Dietrich
- Josef Lissner Laboratory for Biomedical Imaging, Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, Marchioninistr 15, 81377, Munich, Germany
| | - T Saam
- Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, Nussbaumstr. 20, 80336, Munich, Germany
| |
Collapse
|