1
|
McDonald C, Camino E, Escandon R, Finkel RS, Fischer R, Flanigan K, Furlong P, Juhasz R, Martin AS, Villa C, Sweeney HL. Draft Guidance for Industry Duchenne Muscular Dystrophy, Becker Muscular Dystrophy, and Related Dystrophinopathies - Developing Potential Treatments for the Entire Spectrum of Disease. J Neuromuscul Dis 2024; 11:499-523. [PMID: 38363616 DOI: 10.3233/jnd-230219] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2024]
Abstract
Background Duchenne muscular dystrophy (DMD) and related dystrophinopathies are neuromuscular conditions with great unmet medical needs that require the development of effective medical treatments. Objective To aid sponsors in clinical development of drugs and therapeutic biological products for treating DMD across the disease spectrum by integrating advancements, patient registries, natural history studies, and more into a comprehensive guidance. Methods This guidance emerged from collaboration between the FDA, the Duchenne community, and industry stakeholders. It entailed a structured approach, involving multiple committees and boards. From its inception in 2014, the guidance underwent revisions incorporating insights from gene therapy studies, cardiac function research, and innovative clinical trial designs. Results The guidance provides a deeper understanding of DMD and its variants, focusing on patient engagement, diagnostic criteria, natural history, biomarkers, and clinical trials. It underscores patient-focused drug development, the significance of dystrophin as a biomarker, and the pivotal role of magnetic resonance imaging in assessing disease progression. Additionally, the guidance addresses cardiomyopathy's prominence in DMD and the burgeoning field of gene therapy. Conclusions The updated guidance offers a comprehensive understanding of DMD, emphasizing patient-centric approaches, innovative trial designs, and the importance of biomarkers. The focus on cardiomyopathy and gene therapy signifies the evolving realm of DMD research. It acts as a crucial roadmap for sponsors, potentially leading to improved treatments for DMD.
Collapse
Affiliation(s)
| | - Eric Camino
- Parent Project Muscular Dystrophy, Washington, DC, USA
| | - Rafael Escandon
- DGBI Consulting, LLC, Bainbridge Island, Washington, DC, USA
| | | | - Ryan Fischer
- Parent Project Muscular Dystrophy, Washington, DC, USA
| | - Kevin Flanigan
- Center for Experimental Neurotherapeutics, Department of Pediatric Medicine, St. Jude Children's Research Hospital, Memphis, TN, USA
| | - Pat Furlong
- Parent Project Muscular Dystrophy, Washington, DC, USA
| | - Rose Juhasz
- Nationwide Children's Hospital, Columbus, OH, USA
| | - Ann S Martin
- Parent Project Muscular Dystrophy, Washington, DC, USA
| | - Chet Villa
- Trinity Health Michigan, Grand Rapids, MI, USA
| | - H Lee Sweeney
- Cincinnati Children's Hospital Medical Center within the UC Department of Pediatrics, Cincinnati, OH, USA
| |
Collapse
|
2
|
Hu C, Wang T, Leung KWC, Li L, Tong RKY. Muscle Electrical Impedance Properties and Activation Alteration After Functional Electrical Stimulation-Assisted Cycling Training for Chronic Stroke Survivors: A Longitudinal Pilot Study. Front Neurol 2022; 12:746263. [PMID: 34975713 PMCID: PMC8716001 DOI: 10.3389/fneur.2021.746263] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Accepted: 10/29/2021] [Indexed: 11/17/2022] Open
Abstract
Electrical impedance myography (EIM) is a sensitive assessment for neuromuscular diseases to detect muscle inherent properties, whereas surface electromyography (sEMG) is a common technique for monitoring muscle activation. However, the application of EIM in detecting training effects on stroke survivors is relatively few. This study aimed to evaluate the muscle inherent properties and muscle activation alteration after functional electrical stimulation (FES)-assisted cycling training to chronic stroke survivors. Fifteen people with chronic stroke were recruited for 20 sessions of FES-assisted cycling training (40 min/session, 3–5 sessions/week). The periodically stimulated and assessed muscle groups were quadriceps (QC), tibialis anterior (TA), hamstrings (HS), and medial head of gastrocnemius (MG) on the paretic lower extremity. EIM parameters [resistance (R), reactance (X), phase angle (θ), and anisotropy ratio (AR)], clinical scales (Fugl-Meyer Lower Extremity (FMA-LE), Berg Balance Scale (BBS), and 6-min walking test (6MWT)] and sEMG parameters [including root-mean square (RMS) and co-contraction index (CI) value] were collected and computed before and after the training. Linear correlation analysis was conducted between EIM and clinical scales as well as between sEMG and clinical scales. The results showed that motor function of the lower extremity, balance, and walking performance of subjects improved after the training. After training, θ value of TA (P = 0.014) and MG (P = 0.017) significantly increased, and AR of X (P = 0.004) value and AR of θ value (P = 0.041) significantly increased on TA. The RMS value of TA decreased (P = 0.022) and a significant reduction of CI was revealed on TA/MG muscle pair (P < 0.001). Significant correlation was found between EIM and clinical assessments (AR of X value of TA and FMA-LE: r = 0.54, P = 0.046; X value of TA and BBS score: 0.628, P = 0.016), and between sEMG and clinical scores (RMS of TA and BBS score: r = −0.582, P = 0.029). This study demonstrated that FES-assisted cycling training improved lower limb function by developing coordinated muscle activation and facilitating an orderly myofiber arrangement. The current study also indicated that EIM can jointly evaluate lower extremity function alteration with sEMG after rehabilitation training. Clinical Trail Registration: The study was registered on the Clinical Trial Registry (trial registration number: NCT 03208439, https://clinicaltrials.gov/ct2/show/NCT03208439).
Collapse
Affiliation(s)
- Chengpeng Hu
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Tong Wang
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Kenry W C Leung
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Le Li
- Institute of Medical Research, Northwestern Polytechnical University, Xi'an, China
| | - Raymond Kai-Yu Tong
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China
| |
Collapse
|
3
|
Interrater and Intrarater Reliability of Electrical Impedance Myography: A Comparison between Large and Small Handheld Electrode Arrays. JOURNAL OF HEALTHCARE ENGINEERING 2021; 2021:7296322. [PMID: 34765103 PMCID: PMC8577940 DOI: 10.1155/2021/7296322] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/13/2021] [Revised: 07/28/2021] [Accepted: 10/19/2021] [Indexed: 11/17/2022]
Abstract
The objective of this study was to evaluate the interrater and intrarater reliability of electrical impedance myography (EIM) using handheld sensors of different sizes. Electrical impedance myography of the biceps brachii muscle of twenty healthy individuals was performed by two raters using both large and small sensors. The procedures were also repeated 5 to 8 days after the first recording session. The repeatability of the resistance, reactance, and phase angle at two different current frequencies (50 and 100 kHz) was assessed by the intraclass correlation coefficient (ICC). The ICCs of the large sensor were higher than those of the small sensor for both the intrarater and interrater reliabilities. High-frequency current tended to improve the ICC for the small sensor. These results indicate reasonable repeatability of the handheld electrode arrays for EIM measurements. The findings suggest that electrode array should be selected appropriately according to the size of the tested muscle.
Collapse
|
4
|
Hobson-Webb LD, Zwelling PJ, Raja SS, Pifer AN, Kishnani PS. Quantitative muscle ultrasound and electrical impedance myography in late onset Pompe disease: A pilot study of reliability, longitudinal change and correlation with function. Mol Genet Metab Rep 2021; 28:100785. [PMID: 34401343 PMCID: PMC8348861 DOI: 10.1016/j.ymgmr.2021.100785] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Accepted: 07/26/2021] [Indexed: 01/23/2023] Open
Abstract
Background/objectives Late-onset Pompe disease (LOPD) is slowly progressive, making it difficult to assess clinical change and response to interventions. In this study, quantitative muscle ultrasonography (QMUS) and electrical impedance myography (EIM) were evaluated as potential biomarkers. Methods 25 patients with confirmed LOPD were recruited from the Duke Pompe Clinic and evaluated with standard clinical measures, QMUS, standard EIM (sEIM) and hand-held EIM (hEIM). Patients were evaluated at baseline, 12 months and 24 months. MUS, sEIM and hEIM were compared with the clinical data. Five patients were given hEIM devices to perform measurements at home. Results QMUS and hEIM had good reliability as measures of muscle structure and conduction properties. Home, patient-performed hEIM measurements did not differ significantly from those performed in the clinic setting. Thirteen patients completed all follow-up measures. Most measures did not change over the study period, however, vastus lateralis echointensity increased 27%, a sign of declining muscle health. Additionally, significant correlations between QMUS, hEIM and measures of muscle strength and function were present. Conclusions QMUS and hEIM may provide useful outcome measures for future studies in LOPD with hEIM providing an opportunity to collect data at home. Larger, multicenter studies are needed to explore these possibilities.
Collapse
Affiliation(s)
- Lisa D Hobson-Webb
- Department of Neurology/Neuromuscular Division, Duke University, Durham, NC, USA
| | - Paul J Zwelling
- Department of Neurology/Neuromuscular Division, Duke University, Durham, NC, USA
| | - Shruti S Raja
- Department of Neurology/Neuromuscular Division, Duke University, Durham, NC, USA
| | - Ashley N Pifer
- Department of Medicine/Infectious Disease, Duke University, Durham, NC, USA
| | - Priya S Kishnani
- Department of Pediatrics, Division of Medical Genetics, Duke University School of Medicine, Durham, NC, USA
| |
Collapse
|
5
|
Martinez-Gonzalez M, Montilla-Herrador J, García-Vidal JA, Escolar-Reina P, Gacto-Sánchez M, Medina-Mirapeix F. Intra- and inter-rater reliability of electrical impedance myography using adhesive electrodes in healthy volunteers. J Electromyogr Kinesiol 2020; 55:102456. [PMID: 32905888 DOI: 10.1016/j.jelekin.2020.102456] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Revised: 07/31/2020] [Accepted: 08/01/2020] [Indexed: 12/14/2022] Open
Abstract
In spite of the growing use of the electrical impedance myography (EIM) measures for clinical assessment and follow-up of diseased muscle tissue, reliability studies are scarce. We evaluate the reliability of the (EIM) technique using four adhesive electrodes over the muscle of interest. Intra- and inter-rater reliability was studied within the same session and between sessions. Thirty-one healthy and volunteer subjects aged between 20 and 26 years were recruited. Phase angle, reactance and resistance were assessed for each EIM measurement. Intraclass correlation coefficient (ICC) was used to determine the relative reliability. Absolute reliability was expressed as the standard error of measurement and the minimum detectable change. Relative reliability within the same session and between sessions for the EIM technique was excellent (ICCs > 0.9) concerning both intra- and inter-rater reliability, except for the component reactance. The absolute reliability was very high for the three EIM components. EIM measures using four adhesive electrodes over the area of interest is a reliable technique to assess muscle tissue status. This study confirms that these measurement results barely vary depending on the examiner and the moment. The present study also confirms phase angle as the least affected EIM component by examiner and evaluation moment.
Collapse
Affiliation(s)
- Mariano Martinez-Gonzalez
- Instituto Murciano de Investigación Biosanitaria Virgen de la Arrixaca (IMIB-Arrixaca), Murcia, Spain; Department of Physical Therapy, University of Murcia, Murcia, Spain.
| | - Joaquina Montilla-Herrador
- Instituto Murciano de Investigación Biosanitaria Virgen de la Arrixaca (IMIB-Arrixaca), Murcia, Spain; Department of Physical Therapy, University of Murcia, Murcia, Spain
| | - Jose A García-Vidal
- Instituto Murciano de Investigación Biosanitaria Virgen de la Arrixaca (IMIB-Arrixaca), Murcia, Spain; Department of Physical Therapy, University of Murcia, Murcia, Spain
| | - Pilar Escolar-Reina
- Instituto Murciano de Investigación Biosanitaria Virgen de la Arrixaca (IMIB-Arrixaca), Murcia, Spain; Department of Physical Therapy, University of Murcia, Murcia, Spain
| | - Mariano Gacto-Sánchez
- Department of Physical Therapy, EUSES University School, University of Girona, Spain
| | - Francesc Medina-Mirapeix
- Instituto Murciano de Investigación Biosanitaria Virgen de la Arrixaca (IMIB-Arrixaca), Murcia, Spain; Department of Physical Therapy, University of Murcia, Murcia, Spain
| |
Collapse
|
6
|
Alix JJP, McDonough HE, Sonbas B, French SJ, Rao DG, Kadirkamanathan V, McDermott CJ, Healey TJ, Shaw PJ. Multi-dimensional electrical impedance myography of the tongue as a potential biomarker for amyotrophic lateral sclerosis. Clin Neurophysiol 2020; 131:799-808. [PMID: 32066098 DOI: 10.1016/j.clinph.2019.12.418] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2019] [Revised: 12/09/2019] [Accepted: 12/15/2019] [Indexed: 12/11/2022]
Abstract
OBJECTIVE In amyotrophic lateral sclerosis (ALS) bulbar disease biomarkers are lacking. We evaluated a novel tongue electrical impedance myography (EIM) system, utilising both 2D and 3D electrode configurations for detection of tongue pathology. METHODS Longitudinal multi-frequency phase angle spectra were recorded from 41 patients with ALS (baseline, 3 and 6 months) and 30 healthy volunteers (baseline and 6 months). ALS functional rating scale-revised (ALSFRS-R) data and quantitative tongue strength measurements were collected. EIM data were analysed for reliability (intra-class correlation coefficient; ICC) and differences between patients and volunteers ascertained using both univariate (Mann-Whitney U test) and multivariate techniques (feature selection and L2 norm). RESULTS The device produced highly reliable data (pooled ICC: 0.836). Significant EIM differences were apparent between ALS patients and healthy volunteers (P < 0.001). EIM data demonstrated a significant relationship to tongue strength and bulbar ALSFRS-R scores (P < 0.015). The EIM recordings revealed a group level longitudinal change over 6 months and consistently identified patients in whom symptoms or tongue strength changed. CONCLUSIONS The novel EIM tongue system produces reliable data and can differentiate between healthy muscle and ALS-related disease. SIGNIFICANCE Tongue EIM utilising multiple frequencies and electrode configurations has potential as a bulbar disease biomarker in ALS.
Collapse
Affiliation(s)
- James J P Alix
- Sheffield Institute for Translational Neuroscience, University of Sheffield, UK; Department of Clinical Neurophysiology, Sheffield Teaching Hospitals NHS Foundation Trust, UK.
| | - Harry E McDonough
- Sheffield Institute for Translational Neuroscience, University of Sheffield, UK
| | - Buket Sonbas
- Department of Automatic Control and Systems Engineering, University of Sheffield
| | - Sophie J French
- Sheffield Institute for Translational Neuroscience, University of Sheffield, UK
| | - D Ganesh Rao
- Department of Clinical Neurophysiology, Sheffield Teaching Hospitals NHS Foundation Trust, UK
| | | | - Christopher J McDermott
- Sheffield Institute for Translational Neuroscience, University of Sheffield, UK; Department of Neurology, Sheffield Teaching Hospitals NHS Foundation Trust, UK
| | - T Jamie Healey
- Department of Clinical Engineering, Sheffield Teaching Hospitals NHS Foundation Trust, UK
| | - Pamela J Shaw
- Sheffield Institute for Translational Neuroscience, University of Sheffield, UK; Department of Neurology, Sheffield Teaching Hospitals NHS Foundation Trust, UK
| |
Collapse
|
7
|
Roy B, Darras BT, Zaidman CM, Wu JS, Kapur K, Rutkove SB. Exploring the relationship between electrical impedance myography and quantitative ultrasound parameters in Duchenne muscular dystrophy. Clin Neurophysiol 2019; 130:515-520. [PMID: 30772764 DOI: 10.1016/j.clinph.2019.01.018] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2018] [Revised: 12/10/2018] [Accepted: 01/13/2019] [Indexed: 12/14/2022]
Abstract
OBJECTIVES Quantitative ultrasound (QUS), including grayscale level analysis (GLA) and quantitative backscatter analysis (QBA), and electrical impedance myography (EIM) have been proposed as biomarkers in Duchenne muscular dystrophy (DMD). However, the relationship between these methods has not been assessed. METHODS QUS values (including GLA and QBA) and several EIM measures were recorded from six muscles in 36 DMD and 29 healthy boys between ages 5 and 13 years at baseline, 6-months, and 12-months. RESULTS In the DMD boys, a moderate correlation was noted between QUS and EIM parameters, with the strongest correlations being identified for averaged muscle values. Of the individual muscles, biceps brachii and deltoid showed the strongest correlations. For example, in biceps, the QBA/EIM correlation coefficient (Spearman rho) was ≥0.70 (p < 0.01). Importantly, changes in QUS values over 12 months also correlated moderately with changes in EIM parameters and EIM/QBA rho values mostly varied between -0.53 and -0.70 (p ≤ 0.02). No significant correlations were identified in the healthy boys. CONCLUSIONS A moderate correlation of QUS with EIM in DMD boys suggests that the two technologies provide related data but are sensitive to different pathological features of muscle. SIGNIFICANCE The use of both technologies jointly in assessing DMD progression and response to therapy should be considered.
Collapse
Affiliation(s)
- Bhaskar Roy
- Beth Israel Deaconess Medical Center, Boston, MA, USA
| | | | | | - Jim S Wu
- Beth Israel Deaconess Medical Center, Boston, MA, USA
| | - Kush Kapur
- Boston Children's Hospital, Boston, MA, USA
| | | |
Collapse
|
8
|
Hobson-Webb LD, Zwelling PJ, Pifer AN, Killelea CM, Faherty MS, Sell TC, Pastva AM. Point of Care Quantitative Assessment of Muscle Health in Older Individuals: An Investigation of Quantitative Muscle Ultrasound and Electrical Impedance Myography Techniques. Geriatrics (Basel) 2018; 3:geriatrics3040092. [PMID: 31011127 PMCID: PMC6371147 DOI: 10.3390/geriatrics3040092] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2018] [Revised: 12/08/2018] [Accepted: 12/13/2018] [Indexed: 12/13/2022] Open
Abstract
Background: Muscle health is recognized for its critical role in the functionality and well-being of older adults. Readily accessible, reliable, and inexpensive methods of measuring muscle health are needed to advance research and clinical care. Methods: In this prospective, blinded study, 27 patients underwent quantitative muscle ultrasound (QMUS), standard electrical impedance myography (sEIM), and handheld electrical impedance myography (hEIM) of the anterior thigh musculature by two independent examiners. Subjects also had dual-energy X-ray absorptiometry (DEXA) scans and standardized tests of physical function and strength. Data were analyzed for intra- and inter-rater reliability, along with correlations with DEXA and physical measures. Results: Measures of intra- and inter-rater reliability were excellent (>0.90) for all QMUS, sEIM, and hEIM parameters except intra-rater reliability of rectus femoris echointensity (0.87–0.89). There were moderate, inverse correlations between QMUS, sEIM, and hEIM parameters and measures of knee extensor strength. Moderate to strong correlations (0.57–0.81) were noted between investigational measures and DEXA-measured fat mass. Conclusions: QMUS, sEIM and hEIM were highly reliable in a controlled, same-day testing protocol. Multiple correlations with measures of strength and body composition were noted for each method. Point-of-care technologies may provide an alternative means of measuring health.
Collapse
Affiliation(s)
- Lisa D Hobson-Webb
- Duke University Department of Neurology/Neuromuscular Division, Durham, NC 27710, USA.
| | - Paul J Zwelling
- Duke University Department of Neurology/Neuromuscular Division, Durham, NC 27710, USA.
| | - Ashley N Pifer
- Duke University Department of Neurology/Neuromuscular Division, Durham, NC 27710, USA.
| | - Carrie M Killelea
- Duke University Department of Orthopaedic Surgery, Durham, NC 27710, USA.
- Michael W. Krzyzewski Human Performance Laboratory, Durham, NC 27710, USA.
| | - Mallory S Faherty
- Duke University Department of Orthopaedic Surgery, Durham, NC 27710, USA.
- Michael W. Krzyzewski Human Performance Laboratory, Durham, NC 27710, USA.
| | - Timothy C Sell
- Duke University Department of Orthopaedic Surgery, Durham, NC 27710, USA.
- Michael W. Krzyzewski Human Performance Laboratory, Durham, NC 27710, USA.
| | - Amy M Pastva
- Duke University Department of Orthopaedic Surgery, Durham, NC 27710, USA.
- Duke University Claude D. Pepper Older American Independence Center Durham, NC 27710, USA.
| |
Collapse
|
9
|
McLester CN, Dewitt AD, Rooks R, McLester JR. An investigation of the accuracy and reliability of body composition assessed with a handheld electrical impedance myography device. Eur J Sport Sci 2018; 18:763-771. [PMID: 29544083 DOI: 10.1080/17461391.2018.1448458] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
The purpose of this study was to compare the body fat per cent (BF%) assessed with a unique handheld electrical impedance myography (EIM) device, along with other popular methods, to dual-energy X-ray absorptiometry (DXA). Participants included 33 males (aged 24.3 ± 4.6 years) and 38 females (aged 25.3 ± 8.9 years) who completed 2 visits separated by 24-72 h. The assessments included DXA, bioelectrical impedance analysis (BIA), skinfold measures (SKF), and three separate EIM measurements. No significant differences in BF% (P > 0.05) were found between all EIM assessments when compared against DXA for both males and females for each visit. All methods showed no significant differences in BF% (P > 0.05) between days within themselves. Across both days, the standard error of the estimate (SEE) for the EIM measurements ranged from 2.66% to 3.15%, the SEE for BIA was 2.80 and 2.85, and for SKF was 2.90 and 2.82. The 95% limits of agreement ranged from ±5.34% to ±6.38% for EIM measurements and were highest for SKF (±7.42% and ±7.47%). The total error for both days was largest for SKF (5.20% and 5.35%) and lowest for the EIM measurements (2.48-3.24%). This investigation supports use of a handheld EIM device as an accurate and reliable method of estimating BF% compared to DXA in young, apparently healthy individuals with BF% in the range of 10-22% for males and 20-32% in females and suggests this EIM device be considered a viable alternative to other established field measurements in this population.
Collapse
Affiliation(s)
- Cherilyn N McLester
- a Department of Exercise Science and Sport Management , Kennesaw State University , Kennesaw , GA , USA
| | - Alex D Dewitt
- a Department of Exercise Science and Sport Management , Kennesaw State University , Kennesaw , GA , USA
| | - Rasmus Rooks
- a Department of Exercise Science and Sport Management , Kennesaw State University , Kennesaw , GA , USA
| | - John R McLester
- a Department of Exercise Science and Sport Management , Kennesaw State University , Kennesaw , GA , USA
| |
Collapse
|
10
|
Handheld Electrical Impedance Myography Probe for Assessing Carpal Tunnel Syndrome. Ann Biomed Eng 2017; 45:1572-1580. [DOI: 10.1007/s10439-017-1819-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2016] [Accepted: 03/07/2017] [Indexed: 02/06/2023]
|
11
|
Hakim CH, Mijailovic A, Lessa TB, Coates JR, Shin C, Rutkove SB, Duan D. Non-invasive evaluation of muscle disease in the canine model of Duchenne muscular dystrophy by electrical impedance myography. PLoS One 2017; 12:e0173557. [PMID: 28339469 PMCID: PMC5365102 DOI: 10.1371/journal.pone.0173557] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2016] [Accepted: 02/23/2017] [Indexed: 02/07/2023] Open
Abstract
Dystrophin-deficient dogs are by far the best available large animal models for Duchenne muscular dystrophy (DMD), the most common lethal childhood muscle degenerative disease. The use of the canine DMD model in basic disease mechanism research and translational studies will be greatly enhanced with the development of reliable outcome measures. Electrical impedance myography (EIM) is a non-invasive painless procedure that provides quantitative data relating to muscle composition and histology. EIM has been extensively used in neuromuscular disease research in both human patients and rodent models. Recent studies suggest that EIM may represent a highly reliable and convenient outcome measure in DMD patients and the mdx mouse model of DMD. To determine whether EIM can be used as a biomarker of disease severity in the canine model, we performed the assay in fourteen young (~6.6-m-old; 6 normal and 8 affected) and ten mature (~16.9-m-old; 4 normal and 6 affected) dogs of mixed background breeds. EIM was well tolerated with good inter-rater reliability. Affected dogs showed higher resistance, lower reactance and phase. The difference became more straightforward in mature dogs. Importantly, we observed a statistically significant correlation between the EIM data and muscle fibrosis. Our results suggest that EIM is a valuable objective measurement in the canine DMD model.
Collapse
Affiliation(s)
- Chady H. Hakim
- Department of Molecular Microbiology and Immunology, School of Medicine, The University of Missouri, Columbia, MO, United States of America
| | - Alex Mijailovic
- Department of Neurology, Beth Israel Deaconess Medical Center, Boston, MA, United States of America
| | - Thais B. Lessa
- Department of Molecular Microbiology and Immunology, School of Medicine, The University of Missouri, Columbia, MO, United States of America
| | - Joan R. Coates
- Department of Veterinary Medicine and Surgery, College of Veterinary Medicine, University of Missouri, Columbia, MO, United States of America
| | - Carmen Shin
- Department of Neurology, Beth Israel Deaconess Medical Center, Boston, MA, United States of America
| | - Seward B. Rutkove
- Department of Neurology, Beth Israel Deaconess Medical Center, Boston, MA, United States of America
| | - Dongsheng Duan
- Department of Molecular Microbiology and Immunology, School of Medicine, The University of Missouri, Columbia, MO, United States of America
- Department of Biomedical Sciences, College of Veterinary Medicine, University of Missouri, Columbia, MO, United States of America
- Department of Neurology, School of Medicine, University of Missouri, Columbia, MO, United States of America
- Department of Bioengineering, University of Missouri, Columbia, MO, United States of America
| |
Collapse
|