Guven AE, Chiapparelli E, Camino-Willhuber G, Zhu J, Schönnagel L, Amoroso K, Caffard T, Erduran A, Shue J, Sama AA, Girardi FP, Cammisa FP, Hughes AP. Assessing paraspinal muscle atrophy with electrical impedance myography: Limitations and insights. J Orthop Res 2024; 42:2072-2079. [PMID: 38594874 DOI: 10.1002/jor.25848] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Revised: 03/21/2024] [Accepted: 03/27/2024] [Indexed: 04/11/2024]
Abstract
Paraspinal muscle atrophy is gaining attention in spine surgery due to its link to back pain, spinal degeneration and worse postoperative outcomes. Electrical impedance myography (EIM) is a noninvasive diagnostic tool for muscle quality assessment, primarily utilized for patients with neuromuscular diseases. However, EIM's accuracy for paraspinal muscle assessment remains understudied. In this study, we investigated the correlation between EIM readings and MRI-derived muscle parameters, as well as the influence of dermal and subcutaneous parameters on these readings. We retrospectively analyzed patients with lumbar spinal degeneration who underwent paraspinal EIM assessment between May 2023 to July 2023. Paraspinal muscle fatty infiltration (FI) and functional cross-sectional area (fCSA), as well as the subcutaneous thickness were assessed on MRI scans. Skin ultrasound imaging was assessed for dermal thickness and the echogenicities of the dermal and subcutaneous layers. All measurements were performed on the bilaterally. The correlation between EIM readings were compared with ultrasound and MRI parameters using Spearman's correlation analyses. A total of 20 patients (65.0% female) with a median age of 69.5 years (IQR, 61.3-73.8) were analyzed. The fCSA and FI did not significantly correlate with the EIM readings, regardless of frequency. All EIM readings across frequencies correlated with subcutaneous thickness, echogenicity, or dermal thickness. With the current methodology, paraspinal EIM is not a valid alternative to MRI assessment of muscle quality, as it is strongly influenced by the dermal and subcutaneous layers. Further studies are required for refining the methodology and confirming our results.
Collapse
Affiliation(s)
- Ali E Guven
- Department of Orthopaedic Surgery, Hospital for Special Surgery, Weill Cornell Medicine, New York, USA
| | - Erika Chiapparelli
- Department of Orthopaedic Surgery, Hospital for Special Surgery, Weill Cornell Medicine, New York, USA
| | - Gaston Camino-Willhuber
- Department of Orthopaedic Surgery, Hospital for Special Surgery, Weill Cornell Medicine, New York, USA
| | - Jiaqi Zhu
- Biostatistics Core, Hospital for Special Surgery, New York, USA
| | - Lukas Schönnagel
- Department of Orthopaedic Surgery, Hospital for Special Surgery, Weill Cornell Medicine, New York, USA
- Center for Musculoskeletal Surgery, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Krizia Amoroso
- Department of Orthopaedic Surgery, Hospital for Special Surgery, Weill Cornell Medicine, New York, USA
| | - Thomas Caffard
- Department of Orthopaedic Surgery, Hospital for Special Surgery, Weill Cornell Medicine, New York, USA
- Universitätsklinikum Ulm, Klinik für Orthopädie, Ulm, Germany
| | - Ada Erduran
- Department of Electrical Engineering, Technical University Berlin, Berlin, Germany
| | - Jennifer Shue
- Department of Orthopaedic Surgery, Hospital for Special Surgery, Weill Cornell Medicine, New York, USA
| | - Andrew A Sama
- Department of Orthopaedic Surgery, Hospital for Special Surgery, Weill Cornell Medicine, New York, USA
| | - Federico P Girardi
- Department of Orthopaedic Surgery, Hospital for Special Surgery, Weill Cornell Medicine, New York, USA
| | - Frank P Cammisa
- Department of Orthopaedic Surgery, Hospital for Special Surgery, Weill Cornell Medicine, New York, USA
| | - Alexander P Hughes
- Department of Orthopaedic Surgery, Hospital for Special Surgery, Weill Cornell Medicine, New York, USA
| |
Collapse
|
2
|
Wu D, Tian P, Zhang S, Wang Q, Yu K, Wang Y, Gao Z, Huang L, Li X, Zhai X, Tian M, Huang C, Zhang H, Zhang J. A Surface Electromyography (sEMG) System Applied for Grip Force Monitoring. SENSORS (BASEL, SWITZERLAND) 2024; 24:3818. [PMID: 38931601 PMCID: PMC11207591 DOI: 10.3390/s24123818] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2024] [Revised: 05/31/2024] [Accepted: 06/07/2024] [Indexed: 06/28/2024]
Abstract
Muscles play an indispensable role in human life. Surface electromyography (sEMG), as a non-invasive method, is crucial for monitoring muscle status. It is characterized by its real-time, portable nature and is extensively utilized in sports and rehabilitation sciences. This study proposed a wireless acquisition system based on multi-channel sEMG for objective monitoring of grip force. The system consists of an sEMG acquisition module containing four-channel discrete terminals and a host computer receiver module, using Bluetooth wireless transmission. The system is portable, wearable, low-cost, and easy to operate. Leveraging the system, an experiment for grip force prediction was designed, employing the bald eagle search (BES) algorithm to enhance the Random Forest (RF) algorithm. This approach established a grip force prediction model based on dual-channel sEMG signals. As tested, the performance of acquisition terminal proceeded as follows: the gain was up to 1125 times, and the common mode rejection ratio (CMRR) remained high in the sEMG signal band range (96.94 dB (100 Hz), 84.12 dB (500 Hz)), while the performance of the grip force prediction algorithm had an R2 of 0.9215, an MAE of 1.0637, and an MSE of 1.7479. The proposed system demonstrates excellent performance in real-time signal acquisition and grip force prediction, proving to be an effective muscle status monitoring tool for rehabilitation, training, disease condition surveillance and scientific fitness applications.
Collapse
Affiliation(s)
- Dantong Wu
- Institute of Microelectronics of the Chinese Academy of Sciences, Beijing 100029, China; (D.W.); (P.T.); (S.Z.); (Q.W.); (K.Y.); (Y.W.); (Z.G.); (L.H.); (X.L.); (X.Z.); (M.T.); (C.H.)
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Peng Tian
- Institute of Microelectronics of the Chinese Academy of Sciences, Beijing 100029, China; (D.W.); (P.T.); (S.Z.); (Q.W.); (K.Y.); (Y.W.); (Z.G.); (L.H.); (X.L.); (X.Z.); (M.T.); (C.H.)
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Shuai Zhang
- Institute of Microelectronics of the Chinese Academy of Sciences, Beijing 100029, China; (D.W.); (P.T.); (S.Z.); (Q.W.); (K.Y.); (Y.W.); (Z.G.); (L.H.); (X.L.); (X.Z.); (M.T.); (C.H.)
| | - Qihang Wang
- Institute of Microelectronics of the Chinese Academy of Sciences, Beijing 100029, China; (D.W.); (P.T.); (S.Z.); (Q.W.); (K.Y.); (Y.W.); (Z.G.); (L.H.); (X.L.); (X.Z.); (M.T.); (C.H.)
| | - Kang Yu
- Institute of Microelectronics of the Chinese Academy of Sciences, Beijing 100029, China; (D.W.); (P.T.); (S.Z.); (Q.W.); (K.Y.); (Y.W.); (Z.G.); (L.H.); (X.L.); (X.Z.); (M.T.); (C.H.)
| | - Yunfeng Wang
- Institute of Microelectronics of the Chinese Academy of Sciences, Beijing 100029, China; (D.W.); (P.T.); (S.Z.); (Q.W.); (K.Y.); (Y.W.); (Z.G.); (L.H.); (X.L.); (X.Z.); (M.T.); (C.H.)
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Zhixing Gao
- Institute of Microelectronics of the Chinese Academy of Sciences, Beijing 100029, China; (D.W.); (P.T.); (S.Z.); (Q.W.); (K.Y.); (Y.W.); (Z.G.); (L.H.); (X.L.); (X.Z.); (M.T.); (C.H.)
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Lin Huang
- Institute of Microelectronics of the Chinese Academy of Sciences, Beijing 100029, China; (D.W.); (P.T.); (S.Z.); (Q.W.); (K.Y.); (Y.W.); (Z.G.); (L.H.); (X.L.); (X.Z.); (M.T.); (C.H.)
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Xiangyu Li
- Institute of Microelectronics of the Chinese Academy of Sciences, Beijing 100029, China; (D.W.); (P.T.); (S.Z.); (Q.W.); (K.Y.); (Y.W.); (Z.G.); (L.H.); (X.L.); (X.Z.); (M.T.); (C.H.)
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Xingchen Zhai
- Institute of Microelectronics of the Chinese Academy of Sciences, Beijing 100029, China; (D.W.); (P.T.); (S.Z.); (Q.W.); (K.Y.); (Y.W.); (Z.G.); (L.H.); (X.L.); (X.Z.); (M.T.); (C.H.)
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Meng Tian
- Institute of Microelectronics of the Chinese Academy of Sciences, Beijing 100029, China; (D.W.); (P.T.); (S.Z.); (Q.W.); (K.Y.); (Y.W.); (Z.G.); (L.H.); (X.L.); (X.Z.); (M.T.); (C.H.)
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Chengjun Huang
- Institute of Microelectronics of the Chinese Academy of Sciences, Beijing 100029, China; (D.W.); (P.T.); (S.Z.); (Q.W.); (K.Y.); (Y.W.); (Z.G.); (L.H.); (X.L.); (X.Z.); (M.T.); (C.H.)
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Haiying Zhang
- Institute of Microelectronics of the Chinese Academy of Sciences, Beijing 100029, China; (D.W.); (P.T.); (S.Z.); (Q.W.); (K.Y.); (Y.W.); (Z.G.); (L.H.); (X.L.); (X.Z.); (M.T.); (C.H.)
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Jun Zhang
- Institute of Microelectronics of the Chinese Academy of Sciences, Beijing 100029, China; (D.W.); (P.T.); (S.Z.); (Q.W.); (K.Y.); (Y.W.); (Z.G.); (L.H.); (X.L.); (X.Z.); (M.T.); (C.H.)
- University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
3
|
Hansen NJ, Woodman K, Buoy S, Mao S, Barbon CEA, Lai SY, Fuller CD, Hutcheson KA, Sanchez B. Tongue electrical impedance myography correlates with functional, neurophysiologic, and clinical outcome measures in long-term oropharyngeal cancer survivors with and without hypoglossal neuropathy: An exploratory study. Head Neck 2024; 46:581-591. [PMID: 38133080 PMCID: PMC10922903 DOI: 10.1002/hed.27618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2023] [Revised: 12/12/2023] [Accepted: 12/14/2023] [Indexed: 12/23/2023] Open
Abstract
BACKGROUND This pilot study analyzed correlations between tongue electrical impedance myography (EIM), standard tongue electromyography (EMG), and tongue functional measures in N = 4 long-term oropharyngeal cancer (OPC) survivors. METHODS Patients were screened for a supportive care trial (NCT04151082). Hypoglossal nerve function was evaluated with genioglossus needle EMG, functional measures with the Iowa oral performance instrument (IOPI), and multi-frequency tissue composition with tongue EIM. RESULTS Tongue EIM conductivity was higher for patients with EMG-confirmed cranial nerve XII neuropathy than those without (p = 0.005) and in patients with mild versus normal EMG reinnervation ratings (16 kHz EIM: p = 0.051). Tongue EIM correlated with IOPI strength measurements (e.g., anterior maximum isometric lingual strength: r2 = 0.62, p = 0.020). CONCLUSIONS Tongue EIM measures related to tongue strength and the presence of XII neuropathy. Noninvasive tongue EIM may be a convenient adjunctive biomarker to assess tongue health in OPC survivors.
Collapse
Affiliation(s)
- Nathan J. Hansen
- Department of Electrical and Computer Engineering, The University of Utah, Salt Lake City, Utah, USA
| | - Karin Woodman
- Department of Neurology, The University of Texas, MD Anderson Cancer Center, Houston, Texas, USA
| | - Sheila Buoy
- Department of Head and Neck Surgery, Division of Surgery, The University of Texas, MD Anderson Cancer Center, Houston, Texas, USA
| | - Shitong Mao
- Department of Head and Neck Surgery, Division of Surgery, The University of Texas, MD Anderson Cancer Center, Houston, Texas, USA
| | - Carly E. A. Barbon
- Department of Head and Neck Surgery, Division of Surgery, The University of Texas, MD Anderson Cancer Center, Houston, Texas, USA
| | - Stephen Y. Lai
- Department of Head and Neck Surgery, Division of Surgery, The University of Texas, MD Anderson Cancer Center, Houston, Texas, USA
- Division of Radiation Oncology, The University of Texas, MD Anderson Cancer Center, Houston, Texas, USA
| | - C. David Fuller
- Division of Radiation Oncology, The University of Texas, MD Anderson Cancer Center, Houston, Texas, USA
| | - Katherine A. Hutcheson
- Department of Head and Neck Surgery, Division of Surgery, The University of Texas, MD Anderson Cancer Center, Houston, Texas, USA
- Division of Radiation Oncology, The University of Texas, MD Anderson Cancer Center, Houston, Texas, USA
| | - Benjamin Sanchez
- Department of Electrical and Computer Engineering, The University of Utah, Salt Lake City, Utah, USA
| |
Collapse
|
4
|
Offit MB, Khanli HM, Wu T, Lehky TJ. Electrical impedance myography in healthy volunteers. Muscle Nerve 2024; 69:288-294. [PMID: 37787098 PMCID: PMC10922034 DOI: 10.1002/mus.27978] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 09/07/2023] [Accepted: 09/10/2023] [Indexed: 10/04/2023]
Abstract
INTRODUCTION/AIMS Electrical impedance myography (EIM) is a noninvasive technique being used in clinical studies to characterize muscle by phase, reactance, and resistance after application of a low-intensity current. The aim of this study was to obtain 50-kHz EIM data from healthy volunteers (HVs) for use in future clinical and research studies, perform reliability tests on EIM outcome measures, and compare findings with muscle ultrasound variables. METHODS Four arm and four leg muscles of HVs were evaluated using an EIM device with two sensors, P/N 20-0045 and P/N 014-009. Muscles were evaluated individually and eight-muscle average (8MU), four-muscle upper extremity average, and four-muscle lower extremity average. An intraclass correlation coefficient (ICC) was applied to assess interrater, intrarater, and intersensor reliability using a subset of HVs. Ultrasound studies on muscle thickness and elastography were also performed on a subset of HVs. RESULTS For the P/N 20-0045 sensor, the 8MU EIM mean and standard deviation (n = 41) was 14.54 ± 3.31 for phase, 7.04 ± 1.22 for reactance, and 28.91 ± 7.63 for resistance. Reliability for 8MU phase (n = 22) was good to excellent for both interrater (n = 22, ICC = 0.920, 95% CI 0.820 to 0.966) and intrarater (n = 22, ICC = 0.950, 95% CI 0.778 to 0.983). The P/N 014-009 sensor had similar reliability findings. Correlation analyses showed no association between EIM and muscle thickness. DISCUSSION EIM is a reproducible measure of muscle physiology. Obtaining EIM values from HVs allows us to gain a better understanding how EIM may be altered in diseased muscle.
Collapse
Affiliation(s)
- Michelle B. Offit
- Electromyography Section, National Institutes of Health of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, Maryland, USA
- Neurology Department, Georgetown University, Washington, DC, USA
| | - Hadi Mohammad Khanli
- Electromyography Section, National Institutes of Health of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, Maryland, USA
- Neurology Department, City of Hope Comprehensive Cancer Center, Duarte, California, USA
| | - Tianxia Wu
- Clinical Trials Unit, National Institutes of Health of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, Maryland, USA
| | - Tanya J. Lehky
- Electromyography Section, National Institutes of Health of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, Maryland, USA
| |
Collapse
|
5
|
Kapravchuk V, Briko A, Kobelev A, Hammoud A, Shchukin S. An Approach to Using Electrical Impedance Myography Signal Sensors to Assess Morphofunctional Changes in Tissue during Muscle Contraction. BIOSENSORS 2024; 14:76. [PMID: 38391995 PMCID: PMC10886557 DOI: 10.3390/bios14020076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Revised: 01/23/2024] [Accepted: 01/27/2024] [Indexed: 02/24/2024]
Abstract
This present work is aimed at conducting fundamental and exploratory studies of the mechanisms of electrical impedance signal formation. This paper also considers morphofunctional changes in forearm tissues during the performance of basic hand actions. For this purpose, the existing research benches were modernized to conduct experiments of mapping forearm muscle activity by electrode systems on the basis of complexing the electrical impedance signals and electromyography signals and recording electrode systems' pressing force using force transducers. Studies were carried out with the involvement of healthy volunteers in the implementation of vertical movement of the electrode system and ultrasound transducer when the subject's upper limb was positioned in the bed of the stand while performing basic hand actions in order to identify the relationship between the morphofunctional activity of the upper limb muscles and the recorded parameters of the electro-impedance myography signal. On the basis of the results of the studies, including complex measurements of neuromuscular activity on healthy volunteers such as the signals of electro-impedance myography and pressing force, analyses of the morphofunctional changes in tissues during action performance on the basis of ultrasound and MRI studies and the factors influencing the recorded signals of electro-impedance myography are described. The results are of fundamental importance and will enable reproducible electro-impedance myography signals, which, in turn, allow improved anthropomorphic control.
Collapse
Affiliation(s)
- Vladislava Kapravchuk
- Department of Medical and Technical Information Technology, Bauman Moscow State Technical University, 105005 Moscow, Russia; (A.B.); (A.K.); (A.H.); (S.S.)
| | | | | | | | | |
Collapse
|
6
|
Abstract
Although the past two decades have produced exciting discoveries in the genetics and pathology of amyotrophic lateral sclerosis (ALS), progress in developing an effective therapy remains slow. This review summarizes the critical discoveries and outlines the advances in disease characterization, diagnosis, imaging, and biomarkers, along with the current status of approaches to ALS care and treatment. Additional knowledge of the factors driving disease progression and heterogeneity will hopefully soon transform the care for patients with ALS into an individualized, multi-prong approach able to prevent disease progression sufficiently to allow for a dignified life with limited disability.
Collapse
Affiliation(s)
- Hristelina Ilieva
- Jefferson Weinberg ALS Center, Thomas Jefferson University, Philadelphia, PA, USA
| | | | - Justin Kwan
- National Institute of Neurological Disorders and Stroke, National Institute of Health, Bethesda, MD, USA
| |
Collapse
|
7
|
Mandeville R, Sanchez B, Johnston B, Bazarek S, Thum JA, Birmingham A, See RHB, Leochico CFD, Kumar V, Dowlatshahi AS, Brown J, Stashuk D, Rutkove SB. A scoping review of current and emerging techniques for evaluation of peripheral nerve health, degeneration, and regeneration: part 1, neurophysiology. J Neural Eng 2023; 20:041001. [PMID: 37279730 DOI: 10.1088/1741-2552/acdbeb] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Accepted: 06/06/2023] [Indexed: 06/08/2023]
Abstract
Peripheral neuroregeneration research and therapeutic options are expanding exponentially. With this expansion comes an increasing need to reliably evaluate and quantify nerve health. Valid and responsive measures that can serve as biomarkers of the nerve status are essential for both clinical and research purposes for diagnosis, longitudinal follow-up, and monitoring the impact of any intervention. Furthermore, such biomarkers can elucidate regeneration mechanisms and open new avenues for research. Without these measures, clinical decision-making falls short, and research becomes more costly, time-consuming, and sometimes infeasible. As a companion to Part 2, which is focused on non-invasive imaging, Part 1 of this two-part scoping review systematically identifies and critically examines many current and emerging neurophysiological techniques that have the potential to evaluate peripheral nerve health, particularly from the perspective of regenerative therapies and research.
Collapse
Affiliation(s)
- Ross Mandeville
- Department of Neurology, Beth Israel Deaconess Medical Center, Boston, MA 02215, United States of America
| | - Benjamin Sanchez
- Department Electrical and Computer Engineering, University of Utah, Salt Lake City, UT 84112, United States of America
| | - Benjamin Johnston
- Department of Neurosurgery, Brigham and Women's Hospital, Boston, MA 02115, United States of America
| | - Stanley Bazarek
- Department of Neurosurgery, Brigham and Women's Hospital, Boston, MA 02115, United States of America
| | - Jasmine A Thum
- Department of Neurosurgery, Massachusetts General Hospital, Boston, MA 02114, United States of America
| | - Austin Birmingham
- Department of Neurosurgery, Massachusetts General Hospital, Boston, MA 02114, United States of America
| | - Reiner Henson B See
- Department of Neurology, Massachusetts General Hospital, Boston, MA 02114, United States of America
| | - Carl Froilan D Leochico
- Department of Physical Medicine and Rehabilitation, St. Luke's Medical Center, Global City, Taguig, The Philippines
- Department of Rehabilitation Medicine, Philippine General Hospital, University of the Philippines Manila, Manila, The Philippines
| | - Viksit Kumar
- Department of Radiology, Massachusetts General Hospital, Boston, MA 02114, United States of America
| | - Arriyan S Dowlatshahi
- Department of Surgery, Beth Israel Deaconess Medical Center, Boston, MA 02215, United States of America
| | - Justin Brown
- Department of Neurosurgery, Massachusetts General Hospital, Boston, MA 02114, United States of America
| | - Daniel Stashuk
- Department of Systems Design Engineering, University of Waterloo, Ontario N2L 3G1, Canada
| | - Seward B Rutkove
- Department of Neurology, Beth Israel Deaconess Medical Center, Boston, MA 02215, United States of America
| |
Collapse
|
8
|
Rutkove SB, Callegari S, Concepcion H, Mourey T, Widrick J, Nagy JA, Nath AK. Electrical impedance myography detects age-related skeletal muscle atrophy in adult zebrafish. Sci Rep 2023; 13:7191. [PMID: 37137956 PMCID: PMC10156759 DOI: 10.1038/s41598-023-34119-6] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Accepted: 04/25/2023] [Indexed: 05/05/2023] Open
Abstract
Age-related deficits in skeletal muscle function, termed sarcopenia, are due to loss of muscle mass and changes in the intrinsic mechanisms underlying contraction. Sarcopenia is associated with falls, functional decline, and mortality. Electrical impedance myography (EIM)-a minimally invasive, rapid electrophysiological tool-can be applied to animals and humans to monitor muscle health, thereby serving as a biomarker in both preclinical and clinical studies. EIM has been successfully employed in several species; however, the application of EIM to the assessment of zebrafish-a model organism amenable to high-throughput experimentation-has not been reported. Here, we demonstrated differences in EIM measures between the skeletal muscles of young (6 months of age) and aged (33 months of age) zebrafish. For example, EIM phase angle and reactance at 2 kHz showed significantly decreased phase angle (5.3 ± 2.1 versus 10.7 ± 1.5°; p = 0.001) and reactance (89.0 ± 3.9 versus 172.2 ± 54.8 ohms; p = 0.007) in aged versus young animals. Total muscle area, in addition to other morphometric features, was also strongly correlated to EIM 2 kHz phase angle across both groups (r = 0.7133, p = 0.01). Moreover, there was a strong correlation between 2 kHz phase angle and established metrics of zebrafish swimming performance, including turn angle, angular velocity, and lateral motion (r = 0.7253, r = 0.7308, r = 0.7857, respectively, p < 0.01 for all). In addition, the technique was shown to have high reproducibility between repeated measurements with a mean percentage difference of 5.34 ± 1.17% for phase angle. These relationships were also confirmed in a separate replication cohort. Together, these findings establish EIM as a fast, sensitive method for quantifying zebrafish muscle function and quality. Moreover, identifying the abnormalities in the bioelectrical properties of sarcopenic zebrafish provides new opportunities to evaluate potential therapeutics for age-related neuromuscular disorders and to interrogate the disease mechanisms of muscle degeneration.
Collapse
Affiliation(s)
- Seward B Rutkove
- Department of Neurology, Beth Israel Deaconess Medical Center, Boston, MA, 02215, USA.
- Harvard Medical School, Boston, MA, 02215, USA.
| | - Santiago Callegari
- Department of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, 02215, USA
| | - Holly Concepcion
- Department of Neurology, Beth Israel Deaconess Medical Center, Boston, MA, 02215, USA
| | - Tyler Mourey
- Zebrafish Core Facility, Beth Israel Deaconess Medical Center, Boston, MA, 02215, USA
| | - Jeffrey Widrick
- Harvard Medical School, Boston, MA, 02215, USA
- Division of Genetics and Genomics, Boston Children's Hospital, Boston, MA, 02115, USA
| | - Janice A Nagy
- Department of Neurology, Beth Israel Deaconess Medical Center, Boston, MA, 02215, USA
| | - Anjali K Nath
- Harvard Medical School, Boston, MA, 02215, USA.
- Department of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, 02215, USA.
- Broad Institute, Cambridge, MA, 02142, USA.
| |
Collapse
|
9
|
Ha GB, Steinberg BA, Freedman R, Bayés-Genís A, Sanchez B. Safety evaluation of smart scales, smart watches, and smart rings with bioimpedance technology shows evidence of potential interference in cardiac implantable electronic devices. Heart Rhythm 2023; 20:561-571. [PMID: 36997272 DOI: 10.1016/j.hrthm.2022.11.026] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Revised: 11/21/2022] [Accepted: 11/27/2022] [Indexed: 02/24/2023]
Abstract
BACKGROUND Smart scales, smart watches, and smart rings with bioimpedance technology may create interference in patients with cardiac implantable electronic devices (CIEDs). OBJECTIVES The purpose of this study was to determine interference at CIEDs with simulations and benchtop testing, and to compare the results with maximum values defined in the ISO 14117 electromagnetic interference standard for these devices. METHODS The interference at pacing electrodes was determined by simulations on a male and a female computable model. A benchtop evaluation of representative CIEDs from 3 different manufacturers as specified in the ISO 14117 standard also was performed. RESULTS Simulations showed evidence of interference with voltage values exceeding threshold values defined in the ISO 14117 standard. The level of interference varied with the frequency and amplitude of the bioimpedance signal, and between male and female models. The level of interference generated with smart scale and smart rings simulations was lower than with smart watches. Across device manufacturers, generators demonstrated susceptibility to oversensing and pacing inhibition at different signal amplitudes and frequencies. CONCLUSIONS This study evaluated the safety of smart scales, smart watches, and smart rings with bioimpedance technology via simulation and testing. Our results indicate that these consumer electronic devices could interfere in patients with CIEDs. The present findings do not recommend the use of these devices in this population due to potential interference.
Collapse
Affiliation(s)
- Gia-Bao Ha
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, Utah
| | - Benjamin A Steinberg
- Department of Medicine, University of Utah Health Sciences Center, Salt Lake City, Utah
| | - Roger Freedman
- Department of Medicine, University of Utah Health Sciences Center, Salt Lake City, Utah
| | - Antoni Bayés-Genís
- Department of Cardiology, Heart Institute, Hospital Universitari Germans Trias i Pujol, Badalona, Spain; Centro de Investigación Biomédica en Red Enfermedades Cardiovasculares (CIBERCV), Madrid, Spain; Autonomous University of Barcelona, Barcelona, Spain
| | - Benjamin Sanchez
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, Utah.
| |
Collapse
|
10
|
Gong Z, Lo WLA, Wang R, Li L. Electrical impedance myography combined with quantitative assessment techniques in paretic muscle of stroke survivors: Insights and challenges. Front Aging Neurosci 2023; 15:1130230. [PMID: 37020859 PMCID: PMC10069712 DOI: 10.3389/fnagi.2023.1130230] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Accepted: 02/27/2023] [Indexed: 03/18/2023] Open
Abstract
Aging is a non-modifiable risk factor for stroke and the global burden of stroke is continuing to increase due to the aging society. Muscle dysfunction, common sequela of stroke, has long been of research interests. Therefore, how to accurately assess muscle function is particularly important. Electrical impedance myography (EIM) has proven to be feasible to assess muscle impairment in patients with stroke in terms of micro structures, such as muscle membrane integrity, extracellular and intracellular fluids. However, EIM alone is not sufficient to assess muscle function comprehensively given the complex contributors to paretic muscle after an insult. This article discusses the potential to combine EIM and other common quantitative methods as ways to improve the assessment of muscle function in stroke survivors. Clinically, these combined assessments provide not only a distinct advantage for greater accuracy of muscle assessment through cross-validation, but also the physiological explanation on muscle dysfunction at the micro level. Different combinations of assessments are discussed with insights for different purposes. The assessments of morphological, mechanical and contractile properties combined with EIM are focused since changes in muscle structures, tone and strength directly reflect the muscle function of stroke survivors. With advances in computational technology, finite element model and machine learning model that incorporate multi-modal evaluation parameters to enable the establishment of predictive or diagnostic model will be the next step forward to assess muscle function for individual with stroke.
Collapse
Affiliation(s)
- Ze Gong
- Research & Development Institute of Northwestern Polytechnical University in Shenzhen, Shenzhen, China
- Institute of Medical Research, Northwestern Polytechnical University, Xi’an, China
| | - Wai Leung Ambrose Lo
- Department of Rehabilitation Medicine, First Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
| | - Ruoli Wang
- KTH MoveAbility Lab, Department of Engineering Mechanics, KTH Royal Institute of Technology, Stockholm, Sweden
| | - Le Li
- Research & Development Institute of Northwestern Polytechnical University in Shenzhen, Shenzhen, China
- Institute of Medical Research, Northwestern Polytechnical University, Xi’an, China
- *Correspondence: Le Li,
| |
Collapse
|
11
|
Schooling CN, Healey T, McDonough HE, French SJ, McDermott CJ, Shaw PJ, Kadirkamanathan V, Alix JJ. Tensor electrical impedance myography identifies bulbar disease progression in amyotrophic lateral sclerosis. Clin Neurophysiol 2022; 139:69-75. [DOI: 10.1016/j.clinph.2022.04.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 04/08/2022] [Accepted: 04/15/2022] [Indexed: 11/17/2022]
|
12
|
Kwon H, Park HC, Barrera AC, Rutkove SB, Sanchez B. On the measurement of skeletal muscle anisotropic permittivity property with a single cross-shaped needle insertion. Sci Rep 2022; 12:8494. [PMID: 35589764 PMCID: PMC9120124 DOI: 10.1038/s41598-022-12289-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Accepted: 05/09/2022] [Indexed: 11/10/2022] Open
Abstract
Application of minimally invasive methods to enable the measurement of tissue permittivity in the neuromuscular clinic remain elusive. This paper provides a theoretical and modeling study on the measurement of the permittivity of two-dimensional anisotropic tissues such as skeletal muscle with a multi-electrode cross-shaped needle. For this, we design a novel cross-shaped needle with multiple-electrodes and analyse apparent impedance corresponding to the measured impedance. In addition, we propose three methods of estimate anisotropic muscle permittivity. Compared to existing electrical impedance-based needle methods that we have developed, the new needle design and numerical methods associated enable estimating in vivo muscle permittivity values with only a single needle insertion. Being able to measure muscle permittivity directly with a single needle insertion could open up an entirely new area of research with direct clinical application, including using these values to assist in neuromuscular diagnosis and to assess subtle effects of therapeutic intervention on muscle health.
Collapse
Affiliation(s)
- Hyeuknam Kwon
- Division of Software, Yonsei University, Wonju, Republic of Korea.
| | - Hyoung Churl Park
- Department of Mathematics, Yonsei University, Wonju, Republic of Korea
| | - Albert Cheto Barrera
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT, 84112, USA
| | - Seward B Rutkove
- Department of Neurology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, 02215, USA
| | - Benjamin Sanchez
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT, 84112, USA.
| |
Collapse
|
13
|
Altered electrical properties in skeletal muscle of mice with glycogen storage disease type II. Sci Rep 2022; 12:5327. [PMID: 35351934 PMCID: PMC8964715 DOI: 10.1038/s41598-022-09328-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Accepted: 03/14/2022] [Indexed: 01/15/2023] Open
Abstract
Electrical impedance methods, including electrical impedance myography, are increasingly being used as biomarkers of muscle health since they measure passive electrical properties of muscle that alter in disease. One disorder, Pompe Disease (Glycogen storage disease type II (GSDII)), remains relatively unstudied. This disease is marked by dramatic accumulation of intracellular myofiber glycogen. Here we assessed the electrical properties of skeletal muscle in a model of GSDII, the Pompe6neo/6neo (Pompe) mouse. Ex vivo impedance measurements of gastrocnemius (GA) were obtained using a dielectric measuring cell in 30-week-old female Pompe (N = 10) and WT (N = 10) mice. Longitudinal and transverse conductivity, σ, and the relative permittivity, εr, and Cole–Cole complex resistivity parameters at 0 Hz and infinite frequency, ρo and ρ∞, respectively, and the intracellular resistivity, ρintracellular were determined from the impedance data. Glycogen content (GC) was visualized histologically and quantified biochemically. At frequencies > 1 MHz, Pompe mice demonstrated significantly decreased longitudinal and transverse conductivity, increased Cole–Cole parameters, ρo and ρo-ρ∞, and decreased ρintracellular. Changes in longitudinal conductivity and ρintracellular correlated with increased GC in Pompe animals. Ex vivo high frequency impedance measures are sensitive to alterations in intracellular myofiber features considered characteristic of GSDII, making them potentially useful measures of disease status.
Collapse
|
14
|
Luo X, Wang S, Sanchez B. Modeling and simulation of needle electrical impedance myography in nonhomogeneous isotropic skeletal muscle. IEEE JOURNAL OF ELECTROMAGNETICS, RF AND MICROWAVES IN MEDICINE AND BIOLOGY 2022; 6:103-110. [PMID: 35434441 PMCID: PMC9012450 DOI: 10.1109/jerm.2021.3091515] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Objective Needle electrical impedance myography (EIM) is a recently developed technique for neuromuscular evaluation. Despite its preliminary successful clinical application, further understanding is needed to aid interpreting EIM outcomes in nonhomogeneous skeletal muscle measurements. Methods The framework presented models needle EIM measurements in a bidomain isotropic model. Finite element method (FEM) simulations verify the validity of our model predictions studying two cases: a spherical volume surrounded by tissue and a two-layered tissue. Results Our models show that EIM is influenced by the vicinity of tissue with different electrical properties. The apparent resistance, reactance and phase relative errors between our theoretical predictions and FEM simulations in the spherical volume case study are ≤0.2%, ≤1.2% and ≤1.0%, respectively. For the two-layered tissue model case study, the relative errors are ≤2%. Conclusions We propose a bio-physics driven analytical framework describing needle EIM measurements in a nonhomogeneous bidomain tissue model. Clinical impact Our theoretical predictions may lead to new ways for interpreting needle EIM data in neuromuscular diseases that cause compositional changes in muscle content, e.g. connective tissue deposition within the muscle. These changes will manifest themselves by changing the electric properties of the conductor media and will impact impedance values.
Collapse
Affiliation(s)
- Xuesong Luo
- Department of Automation Science and Electric Engineering, Beijing Advanced Innovation Center for Big Data-Based Precision Medicine, Beihang University, Beijing 100083, China,Sanchez Research Lab, Department of Electrical and Computer Engineering, Sorenson Molecular Biotechnology Building, 36 South Wasatch Drive, University of Utah, Salt Lake City, UT 84112, USA
| | - Shaoping Wang
- Department of Automation Science and Electric Engineering, Beijing Advanced Innovation Center for Big Data-Based Precision Medicine, Beihang University, Beijing 100083, China
| | - Benjamin Sanchez
- Sanchez Research Lab, Department of Electrical and Computer Engineering, Sorenson Molecular Biotechnology Building, 36 South Wasatch Drive, University of Utah, Salt Lake City, UT 84112, USA
| |
Collapse
|
15
|
Hu C, Wang T, Leung KWC, Li L, Tong RKY. Muscle Electrical Impedance Properties and Activation Alteration After Functional Electrical Stimulation-Assisted Cycling Training for Chronic Stroke Survivors: A Longitudinal Pilot Study. Front Neurol 2022; 12:746263. [PMID: 34975713 PMCID: PMC8716001 DOI: 10.3389/fneur.2021.746263] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Accepted: 10/29/2021] [Indexed: 11/17/2022] Open
Abstract
Electrical impedance myography (EIM) is a sensitive assessment for neuromuscular diseases to detect muscle inherent properties, whereas surface electromyography (sEMG) is a common technique for monitoring muscle activation. However, the application of EIM in detecting training effects on stroke survivors is relatively few. This study aimed to evaluate the muscle inherent properties and muscle activation alteration after functional electrical stimulation (FES)-assisted cycling training to chronic stroke survivors. Fifteen people with chronic stroke were recruited for 20 sessions of FES-assisted cycling training (40 min/session, 3–5 sessions/week). The periodically stimulated and assessed muscle groups were quadriceps (QC), tibialis anterior (TA), hamstrings (HS), and medial head of gastrocnemius (MG) on the paretic lower extremity. EIM parameters [resistance (R), reactance (X), phase angle (θ), and anisotropy ratio (AR)], clinical scales (Fugl-Meyer Lower Extremity (FMA-LE), Berg Balance Scale (BBS), and 6-min walking test (6MWT)] and sEMG parameters [including root-mean square (RMS) and co-contraction index (CI) value] were collected and computed before and after the training. Linear correlation analysis was conducted between EIM and clinical scales as well as between sEMG and clinical scales. The results showed that motor function of the lower extremity, balance, and walking performance of subjects improved after the training. After training, θ value of TA (P = 0.014) and MG (P = 0.017) significantly increased, and AR of X (P = 0.004) value and AR of θ value (P = 0.041) significantly increased on TA. The RMS value of TA decreased (P = 0.022) and a significant reduction of CI was revealed on TA/MG muscle pair (P < 0.001). Significant correlation was found between EIM and clinical assessments (AR of X value of TA and FMA-LE: r = 0.54, P = 0.046; X value of TA and BBS score: 0.628, P = 0.016), and between sEMG and clinical scores (RMS of TA and BBS score: r = −0.582, P = 0.029). This study demonstrated that FES-assisted cycling training improved lower limb function by developing coordinated muscle activation and facilitating an orderly myofiber arrangement. The current study also indicated that EIM can jointly evaluate lower extremity function alteration with sEMG after rehabilitation training. Clinical Trail Registration: The study was registered on the Clinical Trial Registry (trial registration number: NCT 03208439, https://clinicaltrials.gov/ct2/show/NCT03208439).
Collapse
Affiliation(s)
- Chengpeng Hu
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Tong Wang
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Kenry W C Leung
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Le Li
- Institute of Medical Research, Northwestern Polytechnical University, Xi'an, China
| | - Raymond Kai-Yu Tong
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China
| |
Collapse
|
16
|
Luo X, Zhou Y, Smart T, Grossman D, Sanchez B. Electrical Characterization of Basal Cell Carcinoma Using a Handheld Electrical Impedance Dermography Device. JID INNOVATIONS 2022; 2:100075. [PMID: 35072140 PMCID: PMC8762075 DOI: 10.1016/j.xjidi.2021.100075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2021] [Revised: 11/01/2021] [Accepted: 11/02/2021] [Indexed: 10/28/2022] Open
|
17
|
Luo X, Wang S, Rutkove SB, Sanchez B. Nonhomogeneous volume conduction effects affecting needle electromyography: an analytical and simulation study. Physiol Meas 2021; 42:10.1088/1361-6579/ac38c0. [PMID: 34763321 PMCID: PMC8744488 DOI: 10.1088/1361-6579/ac38c0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Accepted: 11/11/2021] [Indexed: 12/30/2022]
Abstract
Objective.Needle electromyography (EMG) is used to study the electrical behavior of myofiber properties in patients with neuromuscular disorders. However, due to the complexity of electrical potential spatial propagation in nonhomogeneous diseased muscle, a comprehensive understanding of volume conduction effects remains elusive. Here, we develop a framework to study the conduction effect of extracellular abnormalities and electrode positioning on extracellular local field potential (LFP) recordings.Methods.The framework describes the macroscopic conduction of electrical potential in an isotropic, nonhomogeneous (i.e. two tissue) model. Numerical and finite element model simulations are provided to study the conduction effect in prototypical monopolar EMG measurements.Results.LFPs recorded are influenced in amplitude, phase and duration by the electrode position in regards to the vicinity of tissue with different electrical properties.Conclusion.The framework reveals the influence of multiple mechanisms affecting LFPs including changes in the distance between the source-electrode and tissue electrical properties.Clinical significance.Our modeled predictions may lead to new ways for interpreting volume conduction effects on recorded EMG activity, for example in neuromuscular diseases that cause structural and compositional changes in muscle tissue. These change will manifest itself by changing the electric properties of the conductor media and will impact recorded potentials in the area of affected tissue.
Collapse
Affiliation(s)
- Xuesong Luo
- Department of Automation Science and Electric Engineering, Beijing Advanced Innovation Center for Big Data-Based Precision Medicine, Beihang University, Beijing 100083, China
- Sanchez Research Lab, Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT 84112-9206, USA
| | - Shaoping Wang
- Department of Automation Science and Electric Engineering, Beijing Advanced Innovation Center for Big Data-Based Precision Medicine, Beihang University, Beijing 100083, China
| | - Seward B. Rutkove
- Department of Neurology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA 02215, USA
| | - Benjamin Sanchez
- Sanchez Research Lab, Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT 84112-9206, USA
| |
Collapse
|
18
|
Schooling CN, Jamie Healey T, McDonough HE, French SJ, McDermott CJ, Shaw PJ, Kadirkamanathan V, Alix JJP. Tensor electrical impedance myography identifies clinically relevant features in amyotrophic lateral sclerosis. Physiol Meas 2021; 42. [PMID: 34521070 DOI: 10.1088/1361-6579/ac2672] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Accepted: 09/14/2021] [Indexed: 11/12/2022]
Abstract
Objective.Electrical impedance myography (EIM) shows promise as an effective biomarker in amyotrophic lateral sclerosis (ALS). EIM applies multiple input frequencies to characterise muscle properties, often via multiple electrode configurations. Herein, we assess if non-negative tensor factorisation (NTF) can provide a framework for identifying clinically relevant features within a high dimensional EIM dataset.Approach.EIM data were recorded from the tongue of healthy and ALS diseased individuals. Resistivity and reactivity measurements were made for 14 frequencies, in three electrode configurations. This gives 84 (2 × 14 × 3) distinct data points per participant. NTF was applied to the dataset for dimensionality reduction, termed tensor EIM. Significance tests, symptom correlation and classification approaches were explored to compare NTF to using all raw data and feature selection.Main Results.Tensor EIM provides highly significant differentiation between healthy and ALS patients (p< 0.001, AUROC = 0.78). Similarly tensor EIM differentiates between mild and severe disease states (p< 0.001, AUROC = 0.75) and significantly correlates with symptoms (ρ= 0.7,p< 0.001). A trend of centre frequency shifting to the right was identified in diseased spectra, which is in line with the electrical changes expected following muscle atrophy.Significance.Tensor EIM provides clinically relevant metrics for identifying ALS-related muscle disease. This procedure has the advantage of using the whole spectral dataset, with reduced risk of overfitting. The process identifies spectral shapes specific to disease allowing for a deeper clinical interpretation.
Collapse
Affiliation(s)
- Chlöe N Schooling
- Sheffield Institute for Translational Neuroscience, University of Sheffield, United Kingdom.,Department of Automatic Control and Systems Engineering, University of Sheffield, United Kingdom
| | - T Jamie Healey
- Department of Clinical Engineering, Sheffield Teaching Hospitals NHS Foundation Trust, United Kingdom
| | - Harry E McDonough
- Sheffield Institute for Translational Neuroscience, University of Sheffield, United Kingdom
| | - Sophie J French
- Sheffield Institute for Translational Neuroscience, University of Sheffield, United Kingdom
| | | | - Pamela J Shaw
- Sheffield Institute for Translational Neuroscience, University of Sheffield, United Kingdom
| | - Visakan Kadirkamanathan
- Department of Automatic Control and Systems Engineering, University of Sheffield, United Kingdom
| | - James J P Alix
- Sheffield Institute for Translational Neuroscience, University of Sheffield, United Kingdom
| |
Collapse
|
19
|
Luo X, Pulido HVG, Rutkove SB, Sanchez B. A Bioimpedance-Based Device to Assess the Volume Conduction Properties of the Tongue in Neurological Disorders Affecting Bulbar function. IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY 2021; 2:278-285. [PMID: 35402988 PMCID: PMC8940204 DOI: 10.1109/ojemb.2021.3117871] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Revised: 10/01/2021] [Accepted: 10/01/2021] [Indexed: 12/03/2022] Open
Abstract
Goal: Current instruments for bulbar assessment exhibit technical limitations that hinder the execution of clinical studies. The volume conduction properties (VCP) of the tongue reflect ionic content and myofiber integrity and they can serve as a new biomarker for evaluating neurological disorders with bulbar dysfunction. Methods: We designed a standalone bioimpedance measurement system that enables accurate, multi-frequency measurement of tongue anisotropic VCP including conductivity and relative permittivity. The system includes a tongue depressor with 16 non-invasive surface sensors for electrical contact with the tongue at directions 0[Formula: see text], 45[Formula: see text], 90[Formula: see text] and 150[Formula: see text]. The depressor is interfaced with the tongue electronic system with Bluetooth connectivity, and a smartphone application. De-identified patient data is sent by email. Results: We first determined the accuracy of the hardware performing phantom measurements mimicking a broad range of tongue values and determined the error to be [Formula: see text]1%. We then validated our new technology measuring a cohort of 7 healthy human subjects under Institutional Review Board approval. Conclusions: None of the subjects who participated suffered discomfort or gag reflexes. The novel technique presented for intra-oral assessment of tongue VCP provides standard, objective and quantitative data potentially sensitive to alterations in tongue internal structure and composition.
Collapse
Affiliation(s)
- Xuesong Luo
- Sanchez Research Lab, Department of Electrical and Computer EngineeringUniversity of UtahSalt Lake CityUT84112USA
| | | | - Seward B. Rutkove
- Department of Neurology, Beth Israel Deaconess Medical CenterHarvard Medical SchoolBostonMA02115USA
| | - Benjamin Sanchez
- Sanchez Research Lab, Department of Electrical and Computer EngineeringUniversity of UtahSalt Lake CityUT84112USA
| |
Collapse
|
20
|
Luo X, Wang S, Sanchez B. A framework for modeling bioimpedance measurements of nonhomogeneous tissues: a theoretical and simulation study. Physiol Meas 2021; 42. [PMID: 33984840 DOI: 10.1088/1361-6579/ac010d] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2021] [Accepted: 05/13/2021] [Indexed: 11/11/2022]
Abstract
Objective.Bioimpedance technology is experiencing an increased use to assess health in a wide range of new consumer, research and clinical applications. However, the interaction between tissues producing bioimpedance data is often unclear.Methods.This work provides a novel theoretical framework to model bioimpedance measurements of nonhomogeneous tissues. We consider five case studies to validate the usefulness of our approach against finite element model simulations.Results.Theoretical and FEM-simulated apparent resistance and reactance data were in good agreement, with a maximum relative errors <4% and <8%, respectively.Conclusion.The biophysics-driven framework developed provides compact analytical expressions to model nonhomogeneous bioimpedance measurements including multiple tissues with arbitrary shape and electrical properties. This work provides a new perspective to interpret nonhomogeneous bioimpedance measurements usingseries,parallel, andseries-parallelcircuit-like topology equivalents.Significance.Our framework is a new tool to better understand and describe complex nonhomogeneous biological measurements as, for example, cardiac, brain and respiratory applications using (non)invasive electrodes.
Collapse
Affiliation(s)
- Xuesong Luo
- Department of Automation Science and Electric Engineering, Beijing Advanced Innovation Center for Big Data-Based Precision Medicine, Beihang University, Beijing 100083, People's Republic of China.,Sanchez Research Lab, Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT 84112-9206, United States of America
| | - Shaoping Wang
- Department of Automation Science and Electric Engineering, Beijing Advanced Innovation Center for Big Data-Based Precision Medicine, Beihang University, Beijing 100083, People's Republic of China
| | - Benjamin Sanchez
- Sanchez Research Lab, Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT 84112-9206, United States of America
| |
Collapse
|
21
|
Luo X, Sanchez B. In silicomuscle volume conduction study validates in vivomeasurement of tongue volume conduction properties using a user tongue array depressor. Physiol Meas 2021; 42. [PMID: 33690188 DOI: 10.1088/1361-6579/abed36] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Accepted: 03/09/2021] [Indexed: 01/24/2023]
Abstract
Objective.Electrophysiological assessment of the tongue volume conduction properties (VCPs) using our novel multi-electrode user tongue array (UTA) depressor has the promise to serve as a biomarker in patients with bulbar dysfunction. However, whetherin vivodata collected using the UTA depressor accurately reflect the tongue VCPs remains unknown.Approach.To address this question, we performedin silicosimulations of the depressor with an accurate anatomical tongue finite element model (FEM) using healthy human tongue VCP values, namely the conductivity and the relative permittivity, in the sagittal plane (i.e. longitudinal direction) and axial and coronal planes (i.e. transverse directions). We then established the relationship between tongue VCP values simulated from our model to measured human data.Main results.Experimental versus simulated tongue VCP values including their spatial variation were in good agreement with differences well within the variability of the experimental results. Tongue FEM simulations corroborate the feasibility of our UTA depressor in assessing tongue VCPs.Significance.The UTA depressor is a new non-invasive and safe tool to measure tongue VCPs. These electrical properties reflect the tongue's ionic composition and cellular membrane integrity and could serve as a novel electrophysiological biomarker in neurological disorders affecting the tongue.
Collapse
Affiliation(s)
- Xuesong Luo
- Sanchez Research Lab, Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT 84112-9206, United States of America
| | - Benjamin Sanchez
- Sanchez Research Lab, Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT 84112-9206, United States of America
| |
Collapse
|
22
|
Clark BC, Rutkove S, Lupton EC, Padilla CJ, Arnold WD. Potential Utility of Electrical Impedance Myography in Evaluating Age-Related Skeletal Muscle Function Deficits. Front Physiol 2021; 12:666964. [PMID: 34025454 PMCID: PMC8138591 DOI: 10.3389/fphys.2021.666964] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Accepted: 04/13/2021] [Indexed: 12/19/2022] Open
Abstract
Skeletal muscle function deficits associated with advancing age are due to several physiological and morphological changes including loss of muscle size and quality (conceptualized as a reduction in the intrinsic force-generating capacity of a muscle when adjusted for muscle size). Several factors can contribute to loss of muscle quality, including denervation, excitation-contraction uncoupling, increased fibrosis, and myosteatosis (excessive levels of inter- and intramuscular adipose tissue and intramyocellular lipids). These factors also adversely affect metabolic function. There is a major unmet need for tools to rapidly and easily assess muscle mass and quality in clinical settings with minimal patient and provider burden. Herein, we discuss the potential for electrical impedance myography (EIM) as a tool to evaluate muscle mass and quality in older adults. EIM applies weak, non-detectible (e.g., 400 μA), mutifrequency (e.g., 1 kHz–1 MHz) electrical currents to a muscle (or muscle group) through two excitation electrodes, and resulting voltages are measured via two sense electrodes. Measurements are fast (~5 s/muscle), simple to perform, and unaffected by factors such as hydration that may affect other simple measures of muscle status. After nearly 2 decades of study, EIM has been shown to reflect muscle health status, including the presence of atrophy, fibrosis, and fatty infiltration, in a variety of conditions (e.g., developmental growth and maturation, conditioning/deconditioning, and obesity) and neuromuscular diseases states [e.g., amyotrophic lateral sclerosis (ALS) and muscular dystrophies]. In this article, we describe prior work and current evidence of EIM’s potential utility as a measure of muscle health in aging and geriatric medicine.
Collapse
Affiliation(s)
- Brian C Clark
- Ohio Musculoskeletal and Neurological Institute (OMNI), Ohio University, Athens, OH, United States.,Department of Biomedical Sciences, Ohio University, Athens, OH, United States.,Division of Geriatric Medicine, Ohio University, Athens, OH, United States
| | - Seward Rutkove
- Department of Neurology, Harvard Medical School, Beth Israel Deaconess Medical Center, Boston, MA, United States
| | | | - Carlos J Padilla
- Department of Neurology, Ohio State University, Columbus, OH, United States
| | - W David Arnold
- Department of Neurology, Ohio State University, Columbus, OH, United States
| |
Collapse
|
23
|
Sanchez B. Reply to "Putting the patient first: The validity and value of surface-based electrical impedance myography techniques". Clin Neurophysiol 2021; 132:1754-1755. [PMID: 33941477 DOI: 10.1016/j.clinph.2021.03.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2021] [Accepted: 03/29/2021] [Indexed: 11/17/2022]
Affiliation(s)
- Benjamin Sanchez
- Department of Electrical and Computer Engineering, University of Utah, Sorenson Molecular Biotechnology Building, Office 3721, 36 South Wasatch Drive, Salt Lake City, UT 84112-8930, USA.
| |
Collapse
|
24
|
Rutkove SB, Narayanaswami P, David Arnold W, Kolb SJ, Clark BC, Darras BT, Halter RJ, Shefner JM. Putting the patient first: The validity and value of surface-based electrical impedance myography techniques. Clin Neurophysiol 2021; 132:1752-1753. [PMID: 33896693 DOI: 10.1016/j.clinph.2021.03.020] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2021] [Accepted: 03/15/2021] [Indexed: 10/21/2022]
Affiliation(s)
- Seward B Rutkove
- Department of Neurology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA.
| | - Pushpa Narayanaswami
- Department of Neurology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - W David Arnold
- Department of Neurology, The Ohio State University Wexner Medical Center, Columbus, OH, USA
| | - Stephen J Kolb
- Department of Neurology, The Ohio State University Wexner Medical Center, Columbus, OH, USA
| | - Brian C Clark
- Ohio Musculoskeletal and Neurological Institute, Ohio University, Athens, OH, USA
| | - Basil T Darras
- Department of Neurology, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
| | - Ryan J Halter
- Thayer School of Engineering, Dartmouth College, Hanover, NH, USA
| | - Jeremy M Shefner
- Department of Neurology, Barrow Neurological Institute, Phoenix, AZ, USA
| |
Collapse
|
25
|
Cardoner MMDM, Kwon H, Pulido HVG, Nagy J, Rutkove S, Sanchez B. Modeling and Reproducibility of Twin Concentric Electrical Impedance Myography. IEEE Trans Biomed Eng 2021; 68:3068-3077. [PMID: 33661730 DOI: 10.1109/tbme.2021.3063724] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
OBJECTIVE Electrical impedance myography (EIM) is a recent technology to assess muscle health. As of today, the clinical application of EIM has been applied only to evaluate muscle condition using non-invasive surface electrodes in contact with the skin; however, intermediate tissues at the recording site introduce confounding artifacts which reduce the technique's performance as a biomarker of neuromuscular disorders (NMD). Here, we develop and test in humans a new approach using two concentric needles for intramuscular EIM recordings. METHODS First, we study the recording characteristics of dual concentric needle EIM via analytical models and finite element models (FEMs). Next, the validity of the models is verified by performing experiments on saline and agar phantoms. Finally, 8 subjects with various neuromuscular diseases were studied measuring tibialis anterior, biceps, deltoid, adductor pollicis brevis, first dorsal interosseous and flexor carpi radialis muscles. RESULTS Analytical and FEM simulations are in good agreement with a maximum experimental discrepancy 8% and 9% using gauge needles 26 and 30, respectively. The inter-session reproducibility, as measured by the intraclass correlation coefficients for all muscles studied, was 0.926, which is comparable or exceeds the reproducibility of other well-established electrophysiological tests to assess muscle health. CONCLUSION The reproducibility of the technique support future clinical validation of needle EIM for assessment of disease status, either as part of standard patient care or as biomarker measure in clinical trials. SIGNIFICANCE Needle EIM has the potential of becoming a valuable diagnostic tool to evaluate NMD in adult population.
Collapse
|