Guo J, Fan X, Yao Y, Yun J, Wang X, Wang Y, Wang Y. Influence of Head Circumference on the Accuracy of Facial Scanning: An In vitro Study. Int Dent J 2024:S0020-6539(24)01496-5. [PMID: 39341751 DOI: 10.1016/j.identj.2024.09.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2024] [Revised: 08/22/2024] [Accepted: 09/04/2024] [Indexed: 10/01/2024] Open
Abstract
OBJECTIVES This study aimed to investigate the impact of head circumference on the accuracy of three-dimensional (3D) facial scans, focusing on trueness and precision across three mannequin heads of different sizes. MATERIAL AND METHODS Three 3D-printed mannequin heads with circumferences of 30, 50, and 65 cm were used. Ten facial landmarks were identified to measure seven interlandmark distances and two angles. Direct anthropometric measurement, serving as the reference value, was taken using a digital vernier calliper for linear distance, and angle was calculated using the law of cosines. Each head was scanned six times using two systems: a dual-structured light facial scanner (iTom) and a stereophotogrammetry system (3dMD). Digital measurements were analysed using Meshlab and Blender for distances and angles, respectively. Trueness values were determined by comparing measurements to reference measurements, while precision values were derived from the variability among the six scans. Statistical analysis was performed using the Kruskal-Wallis test due to nonhomogeneous variances, followed by Bonferroni correction for pairwise group comparisons. RESULTS For each scanning system, overall deviations in trueness and precision significantly increased with head circumference. Five of the seven distances and one angle showed significant compromises in trueness with larger head circumferences. Most measurements exhibited significant precision decreasing due to head circumference changes, except for N-Pn and Pn-Sn. Additionally, 3dMD displayed higher overall trueness compared to iTom, with five out of seven linear measurements and one angular measurement showing better results. CONCLUSION Head circumference significantly affects both trueness and precision of 3D facial scans for both technologies, suggesting that facial imaging should be used with caution for larger faces. Selecting an appropriate scanning system, such as 3dMD, can help mitigate the negative effects of scanning larger objects.
Collapse
Affiliation(s)
- Jiawen Guo
- Hospital of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, China
| | - Xiaolei Fan
- Hospital of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, China
| | - Yichen Yao
- Hospital of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, China
| | - Jiaojiao Yun
- Hospital of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, China
| | - Xiaoshuang Wang
- Hospital of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, China
| | - Yanlan Wang
- Hospital of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, China
| | - Yan Wang
- Hospital of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, China.
| |
Collapse
|
2
|
Srinivasan M, Berisha F, Bronzino I, Kamnoedboon P, Leles CR. Reliability of a face scanner in measuring the vertical dimension of occlusion. J Dent 2024; 146:105016. [PMID: 38679136 DOI: 10.1016/j.jdent.2024.105016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Revised: 04/18/2024] [Accepted: 04/21/2024] [Indexed: 05/14/2024] Open
Abstract
OBJECTIVE This study evaluated the reliability of a face scanner in measuring the vertical dimension of occlusion (VDO). METHODS Fully dentate volunteers (n = 20; mean-age = 30.0 ± 10.7 years) were recruited. Clinical facial measurements were obtained using a digital caliper and a face scanner (Obiscanner, Fifthingenium, Italy). The scans were imported into a mesh-processing software, and the distances were measured digitally. Measurements were obtained for each participant with the jaws positioned in maximal intercuspation (MI) and with increased vertical distances of 2, 4, and 6 mm. Vertical and horizontal measures were obtained using facial anatomical landmarks: Glabella (GL), Pronasale (PrN), Subnasale (SbN), inferior border of the right and left Alare, Labiale superius (Ls), right and left Cheilion (Ch), Soft Pogonion (SPg), right and left Tragus of the ear (Tr), for all selected vertical positions. Data analysis included intra-class correlation coefficient (ICC), pairwise comparison tests, Bland-Altman plots, and Passing-Bablok regression. RESULTS 120 VDO measurements (clinical=60, digital=60) were recorded by two independent evaluators. Mean differences between digital and clinical measurements ranged from 0.054 ± 0.14 mm to 0.203 ± 0.13 mm. All parameters were strongly correlated (r > 0.93; p < 0.001). ICC estimates revealed excellent reliability, and the measuring procedure yielded the same results on repeated trials irrespective of the raters and measurement methods. Bland-Altman plots revealed a difference, between digital and clinical measurements, of 1.7 % for the vertical measurements. Regression analysis revealed no significant proportional difference between the two methods, so both can be used interchangeably. CONCLUSIONS The findings of this study demonstrate that VDO can be measured accurately from face scans using 3D mesh-processing software and that even small changes in the VDO could be detected using the digital methods. CLINICAL SIGNIFICANCE Findings provide evidence about the reliability of a digital method for jaw relation registrations and may be applied towards incorporating this method into clinical workflows for computer-aided-design/ computer-assisted-manufacturing (CAD-CAM) dentures.
Collapse
Affiliation(s)
- Murali Srinivasan
- Clinic of General-, Special Care- and Geriatric Dentistry, Center for Dental Medicine, University of Zurich, Zurich, Switzerland.
| | - Florentin Berisha
- Clinic of General-, Special Care- and Geriatric Dentistry, Center for Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Innocenzo Bronzino
- Clinic of General-, Special Care- and Geriatric Dentistry, Center for Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Porawit Kamnoedboon
- Clinic of General-, Special Care- and Geriatric Dentistry, Center for Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Claudio Rodrigues Leles
- Clinic of General-, Special Care- and Geriatric Dentistry, Center for Dental Medicine, University of Zurich, Zurich, Switzerland; School of Dentistry, Federal University of Goias, Goiania, Brazil; Department of Reconstructive Dentistry, Division of Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| |
Collapse
|
3
|
Luo Y, Zhao M, Lu J. Accuracy of Smartphone-Based Three-Dimensional Facial Scanning System: A Systematic Review. Aesthetic Plast Surg 2024:10.1007/s00266-024-04121-y. [PMID: 38831068 DOI: 10.1007/s00266-024-04121-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2023] [Accepted: 05/02/2024] [Indexed: 06/05/2024]
Abstract
BACKGROUND Recently, the integration of 3D face scanning into smartphones has raised vast interest in plastic surgery. With the release of smartphones featuring 3D face scanning technology, users now can capture detailed 3D models of their faces using their smartphones. However, trueness and precision of this system is less well established. METHODS PubMed, Cochrane Library, Embase, ScienceDirect, Scopus, and Web of Science databases were searched for studies evaluating 3D scanning of smartphone devices and conventional 3D imaging systems from January 1, 2017, to June 1, 2023. A qualitative systematic review was conducted by two review authors after independently selecting studies, extracting data, and assessing the risk of bias of included studies. RESULTS A total of 11 studies were included, all focusing on the accuracy of smartphone 3D facial scanning. The results show that although smartphones perform poorly on deep and irregular surfaces, they are accurate enough for clinical applications and have the advantage of being economical and portable. CONCLUSIONS Smartphone-based 3D facial scanning has been basically validated for clinical application, showing broad clinical application prospects in plastic surgery. LEVEL OF EVIDENCE II This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Collapse
Affiliation(s)
- Yuna Luo
- Cranio-Maxillo-Facial Surgery Department, Plastic Surgery Hospital, Chinese Academy of Medical Sciences, Peking Union Medical College, No. 33 Ba-Da-Chu Road, Shi-Jing-Shan District, Beijing, 100144, China
- Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China
| | - Minghao Zhao
- Cranio-Maxillo-Facial Surgery Department, Plastic Surgery Hospital, Chinese Academy of Medical Sciences, Peking Union Medical College, No. 33 Ba-Da-Chu Road, Shi-Jing-Shan District, Beijing, 100144, China
| | - Jianjian Lu
- Cranio-Maxillo-Facial Surgery Department, Plastic Surgery Hospital, Chinese Academy of Medical Sciences, Peking Union Medical College, No. 33 Ba-Da-Chu Road, Shi-Jing-Shan District, Beijing, 100144, China.
| |
Collapse
|
4
|
Generalova AN, Vikhrov AA, Prostyakova AI, Apresyan SV, Stepanov AG, Myasoedov MS, Oleinikov VA. Polymers in 3D printing of external maxillofacial prostheses and in their retention systems. Int J Pharm 2024; 657:124181. [PMID: 38697583 DOI: 10.1016/j.ijpharm.2024.124181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2023] [Revised: 04/12/2024] [Accepted: 04/28/2024] [Indexed: 05/05/2024]
Abstract
Maxillofacial defects, arising from trauma, oncological disease or congenital abnormalities, detrimentally affect daily life. Prosthetic repair offers the aesthetic and functional reconstruction with the help of materials mimicking natural tissues. 3D polymer printing enables the design of patient-specific prostheses with high structural complexity, as well as rapid and low-cost fabrication on-demand. However, 3D printing for prosthetics is still in the early stage of development and faces various challenges for widespread use. This is because the most suitable polymers for maxillofacial restoration are soft materials that do not have the required printability, mechanical strength of the printed parts, as well as functionality. This review focuses on the challenges and opportunities of 3D printing techniques for production of polymer maxillofacial prostheses using computer-aided design and modeling software. Review discusses the widely used polymers, as well as their blends and composites, which meet the most important assessment criteria, such as the physicochemical, biological, aesthetic properties and processability in 3D printing. In addition, strategies for improving the polymer properties, such as their printability, mechanical strength, and their ability to print multimaterial and architectural structures are highlighted. The current state of the prosthetic retention system is presented with a focus on actively used polymer adhesives and the recently implemented prosthesis-supporting osseointegrated implants, with an emphasis on their creation from 3D-printed polymers. The successful prosthetics is discussed in terms of the specificity of polymer materials at the restoration site. The approaches and technological prospects are also explored through the examples of the nasal, auricle and ocular prostheses, ranging from prototypes to end-use products.
Collapse
Affiliation(s)
- Alla N Generalova
- Shemyakin-Ovchinnikov Institute of Bioorganic Chemistry of the Russian Academy of Sciences, Miklukho-Maklaya 16/10, 117997 Moscow, Russia; Federal Scientific Research Center "Crystallography and Photonics" of the Russian Academy of Sciences, 119333 Moscow, Russia.
| | - Alexander A Vikhrov
- Shemyakin-Ovchinnikov Institute of Bioorganic Chemistry of the Russian Academy of Sciences, Miklukho-Maklaya 16/10, 117997 Moscow, Russia
| | - Anna I Prostyakova
- Shemyakin-Ovchinnikov Institute of Bioorganic Chemistry of the Russian Academy of Sciences, Miklukho-Maklaya 16/10, 117997 Moscow, Russia
| | - Samvel V Apresyan
- Institute of Digital Dentistry, Medical Institute, Peoples' Friendship University of Russia (RUDN University), Miklukho-Maklaya 6, 117198 Moscow, Russia
| | - Alexander G Stepanov
- Institute of Digital Dentistry, Medical Institute, Peoples' Friendship University of Russia (RUDN University), Miklukho-Maklaya 6, 117198 Moscow, Russia
| | - Maxim S Myasoedov
- Shemyakin-Ovchinnikov Institute of Bioorganic Chemistry of the Russian Academy of Sciences, Miklukho-Maklaya 16/10, 117997 Moscow, Russia
| | - Vladimir A Oleinikov
- Shemyakin-Ovchinnikov Institute of Bioorganic Chemistry of the Russian Academy of Sciences, Miklukho-Maklaya 16/10, 117997 Moscow, Russia
| |
Collapse
|
5
|
Revilla-León M, Zeitler JM, Kois JC. Scan body system to translate natural head position and virtual mounting into a 3-dimensional virtual patient: A dental technique. J Prosthet Dent 2024; 131:787-792. [PMID: 35672165 DOI: 10.1016/j.prosdent.2022.04.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Revised: 04/13/2022] [Accepted: 04/13/2022] [Indexed: 10/18/2022]
Abstract
Various techniques have been developed for a 3-dimensional (3D) virtual patient. However, those techniques do not enable the registration of the alignment of the facial and intraoral digital scans, the registration for the mounting on the virtual articulator, and the integration of the natural head position (NHP) together. In the present manuscript, a scan body system is described that assists with the translation of the horizon orientation within the NHP of the patient into a computer-aided design software program. Additionally, the scan body system facilitates the facial and intraoral alignment, as well as the mounting of the maxillary virtual cast on the virtual articulator. This scan body system facilitates the integration of the 3D virtual patient and reduces chair and laboratory time.
Collapse
Affiliation(s)
- Marta Revilla-León
- Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash; Director of Research and Digital Dentistry, Kois Center, Seattle, Wash; Adjunct Professor, Department of Prosthodontics, Tufts University, Boston, Mass.
| | | | - John C Kois
- Founder and Director, Kois Center, Seattle, Wash; Affiliate Professor, Graduate Prosthodontics, Department of Restorative Dentistry, University of Washington, Seattle, Wash; Private practice, Seattle, Wash
| |
Collapse
|
6
|
Singh P, Bornstein MM, Hsung RTC, Ajmera DH, Leung YY, Gu M. Frontiers in Three-Dimensional Surface Imaging Systems for 3D Face Acquisition in Craniofacial Research and Practice: An Updated Literature Review. Diagnostics (Basel) 2024; 14:423. [PMID: 38396462 PMCID: PMC10888365 DOI: 10.3390/diagnostics14040423] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 02/02/2024] [Accepted: 02/08/2024] [Indexed: 02/25/2024] Open
Abstract
Digitalizing all aspects of dental care is a contemporary approach to ensuring the best possible clinical outcomes. Ongoing advancements in 3D face acquisition have been driven by continuous research on craniofacial structures and treatment effects. An array of 3D surface-imaging systems are currently available for generating photorealistic 3D facial images. However, choosing a purpose-specific system is challenging for clinicians due to variations in accuracy, reliability, resolution, and portability. Therefore, this review aims to provide clinicians and researchers with an overview of currently used or potential 3D surface imaging technologies and systems for 3D face acquisition in craniofacial research and daily practice. Through a comprehensive literature search, 71 articles meeting the inclusion criteria were included in the qualitative analysis, investigating the hardware, software, and operational aspects of these systems. The review offers updated information on 3D surface imaging technologies and systems to guide clinicians in selecting an optimal 3D face acquisition system. While some of these systems have already been implemented in clinical settings, others hold promise. Furthermore, driven by technological advances, novel devices will become cost-effective and portable, and will also enable accurate quantitative assessments, rapid treatment simulations, and improved outcomes.
Collapse
Affiliation(s)
- Pradeep Singh
- Discipline of Orthodontics, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China; (P.S.); (D.H.A.)
| | - Michael M. Bornstein
- Department of Oral Health & Medicine, University Center for Dental Medicine Basel UZB, University of Basel, Mattenstrasse 40, 4058 Basel, Switzerland;
| | - Richard Tai-Chiu Hsung
- Department of Computer Science, Hong Kong Chu Hai College, Hong Kong SAR, China;
- Discipline of Oral and Maxillofacial Surgery, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China;
| | - Deepal Haresh Ajmera
- Discipline of Orthodontics, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China; (P.S.); (D.H.A.)
| | - Yiu Yan Leung
- Discipline of Oral and Maxillofacial Surgery, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China;
| | - Min Gu
- Discipline of Orthodontics, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China; (P.S.); (D.H.A.)
| |
Collapse
|
7
|
Zhang C, Lu T, Wang L, Wen J, Huang Z, Lin S, Zhou Y, Li G, Li H. Three-dimensional analysis of hard and soft tissue changes in skeletal class II patients with high mandibular plane angle undergoing surgery. Sci Rep 2024; 14:2519. [PMID: 38291067 PMCID: PMC10827781 DOI: 10.1038/s41598-024-51322-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Accepted: 01/03/2024] [Indexed: 02/01/2024] Open
Abstract
This study aimed to study 3-dimensional (3D) changes of hard and soft tissues of skeletal class II patients after 2-jaw surgery and genioplasty. 32 adult patients diagnosed with mandibular hypoplasia who underwent 2-jaw surgery of maxillary impaction, mandibular advancement and genioplasty were enrolled. Cone-beam computed tomography and 3D stereophotogrammetry was conducted 1 week before and 6 months after surgery. Dolphin imaging software was used to establish a 3D digitizing model and 3D measurement system. Paired t-test was performed to compare the values before and after surgery. Pearson's correlation test assessed the degree of correlations between hard and soft tissue change. The mean impaction of the maxilla was 2.600 ± 3.088 mm at A. The mean advancement of the mandible was 7.806 ± 2.647 mm at B. There was a significant upward and forward movement for most landmarks of the nose and lip, while a significant decrease in nasal tip height (lateral view), upper lip height, and upper and lower vermilion height. The nose's width was significantly increased. For maxillary, Sn, Ac-r, Ac-l, and Ls demonstrated a significant correlation with A and U1 in the anteroposterior axis. However, there were no significant correlations among them in the vertical axis. For mandibular, Li demonstrated a significant correlation with L1 in the anteroposterior axis specifically for the mandible. Notably, correlations between the landmarks of the chin's hard and soft tissues were observed across all axes. The utilization of 3-D analysis facilitated a quantitative comprehension of both hard and soft tissues, thereby furnishing valuable insights for the strategic formulation of orthognathic treatment plans targeting patients with skeletal class II conditions.
Collapse
Affiliation(s)
- Caixia Zhang
- Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Research Institute of Stomatology, Nanjing University, Nanjing, China
| | - Tong Lu
- Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Research Institute of Stomatology, Nanjing University, Nanjing, China
| | - Lichan Wang
- Nanjing Lishui Stomatological Hospital, Nanjing, China
| | - Juan Wen
- Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Research Institute of Stomatology, Nanjing University, Nanjing, China
| | - Ziwei Huang
- Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Research Institute of Stomatology, Nanjing University, Nanjing, China
| | - Shuang Lin
- Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Research Institute of Stomatology, Nanjing University, Nanjing, China
| | - Yiwen Zhou
- Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Research Institute of Stomatology, Nanjing University, Nanjing, China
| | - Guifeng Li
- Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Research Institute of Stomatology, Nanjing University, Nanjing, China.
| | - Huang Li
- Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Research Institute of Stomatology, Nanjing University, Nanjing, China.
| |
Collapse
|
8
|
Chen B, Cao R, Song D, Qiu P, Liao C, Li Y. Predicting obstructive sleep apnea hypopnea syndrome using three-dimensional optical devices: A systematic review. Digit Health 2024; 10:20552076241271749. [PMID: 39119554 PMCID: PMC11307370 DOI: 10.1177/20552076241271749] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Accepted: 07/01/2024] [Indexed: 08/10/2024] Open
Abstract
Purpose As a global health concern, the diagnosis of obstructive sleep apnea hypopnea syndrome (OSAHS), characterized by partial reductions and complete pauses in ventilation, has garnered significant scientific and public attention. With the advancement of digital technology, the utilization of three-dimensional (3D) optical devices demonstrates unparalleled potential in diagnosing OSAHS. This study aimed to review the current literature to assess the accuracy of 3D optical devices in identifying the prevalence and severity of OSAHS. Methods A systematic literature search was conducted in the Web of Science, Scopus, PubMed/MEDLINE, and Cochrane Library databases for English studies published up to April 2024. Peer-reviewed researches assessing the diagnostic utility of 3D optical devices for OSAHS were included. The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) guideline was employed to appraise the risk of bias. Results The search yielded 3216 results, with 10 articles meeting the inclusion criteria for this study. Selected studies utilized structured light scanners, stereophotogrammetry, and red, green, blue-depth (RGB-D) cameras. Stereophotogrammetry-based 3D optical devices exhibited promising potential in OSAHS prediction. Conclusions The utilization of 3D optical devices holds considerable promise for OSAHS diagnosis, offering potential improvements in accuracy, cost reduction, and time efficiency. However, further clinical data are essential to assist clinicians in the early detection of OSAHS using 3D optical devices.
Collapse
Affiliation(s)
| | | | - Danni Song
- Shanghai Engineering Research Center of Tooth Restoration and Regeneration & Tongji Research Institute of Stomatology & Department of Orthodontics, Stomatological Hospital and Dental School, Tongji University, Shanghai, China
| | - Piaopiao Qiu
- Shanghai Engineering Research Center of Tooth Restoration and Regeneration & Tongji Research Institute of Stomatology & Department of Orthodontics, Stomatological Hospital and Dental School, Tongji University, Shanghai, China
| | - Chongshan Liao
- Shanghai Engineering Research Center of Tooth Restoration and Regeneration & Tongji Research Institute of Stomatology & Department of Orthodontics, Stomatological Hospital and Dental School, Tongji University, Shanghai, China
| | - Yongming Li
- Yongming Li, Shanghai Engineering Research Center of Tooth Restoration and Regeneration & Tongji Research Institute of Stomatology & Department of Orthodontics, Stomatological Hospital and Dental School, Tongji University, Shanghai, China.
| |
Collapse
|
9
|
Rosmaninho A, Zeitler JM, Vedovato E, Kois JC, Revilla-León M. Using an additively manufactured natural head position reference device to transfer the horizon orientation plane and integrate it with a 3-dimensional virtual patient: A dental technique. J Prosthet Dent 2024; 131:7-12. [PMID: 35382942 DOI: 10.1016/j.prosdent.2022.02.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Revised: 02/14/2022] [Accepted: 02/15/2022] [Indexed: 10/18/2022]
Abstract
A virtual patient is obtained by aligning a patient's digital information, including facial and intraoral digital scans with or without hard tissue information from a cone beam computed tomography scan. However, while computer-aided design programs facilitate virtual patient integration, they do not provide a way to relate the horizon orientation with the patient's horizontal and vertical facial references. The present technique describes a way of relating the horizon orientation plane to the natural head position of the patient. An additively manufactured natural head position reference device was used to transfer the horizon orientation plane to the 3-dimensional virtual patient.
Collapse
Affiliation(s)
| | | | | | - John C Kois
- Founder and Director Kois Center, Seattle, Wash; Affiliate Professor, Graduate Prosthodontics, Department of Restorative Dentistry, University of Washington, Seattle, Wash; Private Practice, Seattle, Wash
| | - Marta Revilla-León
- Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash; Director of Research and Digital Dentistry, Kois Center, Seattle, Wash; Adjunct Professor, Department of Prosthodontics, Tufts University, Boston, Mass.
| |
Collapse
|
10
|
Cen Y, Huang X, Liu J, Qin Y, Wu X, Ye S, Du S, Liao W. Application of three-dimensional reconstruction technology in dentistry: a narrative review. BMC Oral Health 2023; 23:630. [PMID: 37667286 PMCID: PMC10476426 DOI: 10.1186/s12903-023-03142-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Accepted: 06/16/2023] [Indexed: 09/06/2023] Open
Abstract
BACKGROUND Three-dimensional(3D) reconstruction technology is a method of transforming real goals into mathematical models consistent with computer logic expressions and has been widely used in dentistry, but the lack of review and summary leads to confusion and misinterpretation of information. The purpose of this review is to provide the first comprehensive link and scientific analysis of 3D reconstruction technology and dentistry to bridge the information bias between these two disciplines. METHODS The IEEE Xplore and PubMed databases were used for rigorous searches based on specific inclusion and exclusion criteria, supplemented by Google Academic as a complementary tool to retrieve all literature up to February 2023. We conducted a narrative review focusing on the empirical findings of the application of 3D reconstruction technology to dentistry. RESULTS We classify the technologies applied to dentistry according to their principles and summarize the different characteristics of each category, as well as the different application scenarios determined by these characteristics of each technique. In addition, we indicate their development prospects and worthy research directions in the field of dentistry, from individual techniques to the overall discipline of 3D reconstruction technology, respectively. CONCLUSIONS Researchers and clinicians should make different decisions on the choice of 3D reconstruction technology based on different objectives. The main trend in the future development of 3D reconstruction technology is the joint application of technology.
Collapse
Affiliation(s)
- Yueyan Cen
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, No.14, 3Rd Section of Ren Min Nan Rd. Chengdu, Sichuan, 610041, China
| | - Xinyue Huang
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, No.14, 3Rd Section of Ren Min Nan Rd. Chengdu, Sichuan, 610041, China
| | - Jialing Liu
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, No.14, 3Rd Section of Ren Min Nan Rd. Chengdu, Sichuan, 610041, China
| | - Yichun Qin
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, No.14, 3Rd Section of Ren Min Nan Rd. Chengdu, Sichuan, 610041, China
| | - Xinrui Wu
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, No.14, 3Rd Section of Ren Min Nan Rd. Chengdu, Sichuan, 610041, China
| | - Shiyang Ye
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, No.14, 3Rd Section of Ren Min Nan Rd. Chengdu, Sichuan, 610041, China
| | - Shufang Du
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, No.14, 3Rd Section of Ren Min Nan Rd. Chengdu, Sichuan, 610041, China.
| | - Wen Liao
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, No.14, 3Rd Section of Ren Min Nan Rd. Chengdu, Sichuan, 610041, China.
| |
Collapse
|
11
|
Kühlman DC, Almuzian M, Coppini C, Alzoubi EE. Accuracy (trueness and precision) of four tablet-based applications for three-dimensional facial scanning: an in-vitro study.: Tablet-based applications for 3D facial scanning. J Dent 2023:104533. [PMID: 37149254 DOI: 10.1016/j.jdent.2023.104533] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 04/01/2023] [Accepted: 05/03/2023] [Indexed: 05/08/2023] Open
Abstract
OBJECTIVES This study aimed to investigate the overall and regional accuracy (trueness and precision) of digital three-dimensional (3D) facial scans obtained from four tablet-based applications, which were (Bellus) the Bellus Dental Pro® (Bellus3D, Inc. Campbell, CA, USA), (Capture) the Capture®: 3D Scan Anything (Standard Cyborg, Inc. San Francisco, CA, USA), (Heges) the Heges® (by Marek Simonik, Ostrava, North Moravia, Czech Republic), and (Scandy) the Scandy Pro 3D Scanner® (Scandy LLC, New Orleans, LA, USA). METHODS A mannequin's face was marked with 63 landmarks. Subsequently, it was scanned 5 times using each scan application on an iPad Pro® (Apple Inc., Cupertino, CA, USA). The digital measurements were obtained with MeshLab® (CNR-ISTI, Pisa, Tuscany, Italy) and compared to the manual measurements using a digital vernier caliper (Truper Herramientas S.A., Colonia Granada, Mexico City, Mexico). The absolute mean difference and the standard deviation of the dimensional discrepancies were calculated. Moreover, the data were analysed by using one-way ANOVA, Levene's test, and Bonferroni´s correction. RESULTS The absolute mean trueness values were Bellus 0.41 ± 0.35 mm, Capture 0.38 ± 0.37 mm, Heges 0.39 ± 0.38 mm, and Scandy 0.47 ± 0.44 mm. Moreover, precision values were Bellus 0.46 mm, Capture 0.46 mm, Heges 0.54 mm, and Scandy 0.64 mm. Comparing the regions, Capture and Scandy showed the highest absolute mean difference, which was 0.81 mm in the Frontal and Zygomaticofacial regions, respectively. CONCLUSIONS The trueness and precision of all four tablet-based applications were clinically acceptable for diagnosis and treatment planning. CLINICAL SIGNIFICANCE The future of the three-dimensional facial scan is auspicious, and it has the potential to be affordable, accurate, and of great value for clinicians in their daily practice.
Collapse
Affiliation(s)
- Deise Caldas Kühlman
- Department of Child Dental Health and Orthodontics, Faculty of Dental Surgery, Medical School University of Malta, Msida MSD 2080, Malta.
| | - Mohammed Almuzian
- ASMD College, Honorary Research Fellow, Department of Orthodontics, Edinburgh Medical School, University of Edinburgh, Lauriston building, Lauriston place, Edinburgh, EH3 9HA
| | - Christianne Coppini
- Department of Child Dental Health and Orthodontics, Faculty of Dental Surgery, Medical School University of Malta, Msida MSD 2080, Malta
| | - Emad Eddin Alzoubi
- Department of Child Dental Health and Orthodontics, Faculty of Dental Surgery, Medical School University of Malta, Msida MSD 2080, Malta
| |
Collapse
|
12
|
Cho RY, Byun SH, Yi SM, Ahn HJ, Nam YS, Park IY, On SW, Kim JC, Yang BE. Comparative Analysis of Three Facial Scanners for Creating Digital Twins by Focusing on the Difference in Scanning Method. Bioengineering (Basel) 2023; 10:bioengineering10050545. [PMID: 37237615 DOI: 10.3390/bioengineering10050545] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 04/24/2023] [Accepted: 04/27/2023] [Indexed: 05/28/2023] Open
Abstract
BACKGROUND Multi-dimensional facial imaging is increasingly used in hospital clinics. A digital twin of the face can be created by reconstructing three-dimensional (3D) facial images using facial scanners. Therefore, the reliability, strengths, and weaknesses of scanners should be investigated and approved; Methods: Images obtained from three facial scanners (RayFace, MegaGen, and Artec Eva) were compared with cone-beam computed tomography images as the standard. Surface discrepancies were measured and analyzed at 14 specific reference points; Results: All scanners used in this study achieved acceptable results, although only scanner 3 obtained preferable results. Each scanner exhibited weak and strong points because of differences in the scanning methods. Scanner 2 exhibited the best result on the left endocanthion; scanner 1 achieved the best result on the left exocanthion and left alare; and scanner 3 achieved the best result on the left exocanthion (both cheeks); Conclusions: These comparative analysis data can be used when creating digital twins through segmentation, selecting and merging data, or developing a new scanner to overcome all shortcomings.
Collapse
Affiliation(s)
- Ran-Yeong Cho
- Department of Oral and Maxillofacial Surgery, Hallym University Sacred Heart Hospital, Anyang 14066, Republic of Korea
- Graduate School of Clinical Dentistry, Hallym University, Chuncheon 24252, Republic of Korea
- Institute of Clinical Dentistry, Hallym University, Chuncheon 24252, Republic of Korea
| | - Soo-Hwan Byun
- Department of Oral and Maxillofacial Surgery, Hallym University Sacred Heart Hospital, Anyang 14066, Republic of Korea
- Graduate School of Clinical Dentistry, Hallym University, Chuncheon 24252, Republic of Korea
- Institute of Clinical Dentistry, Hallym University, Chuncheon 24252, Republic of Korea
| | - Sang-Min Yi
- Department of Oral and Maxillofacial Surgery, Hallym University Sacred Heart Hospital, Anyang 14066, Republic of Korea
- Graduate School of Clinical Dentistry, Hallym University, Chuncheon 24252, Republic of Korea
- Institute of Clinical Dentistry, Hallym University, Chuncheon 24252, Republic of Korea
| | - Hee-Ju Ahn
- Department of Oral and Maxillofacial Surgery, Hallym University Sacred Heart Hospital, Anyang 14066, Republic of Korea
- Graduate School of Clinical Dentistry, Hallym University, Chuncheon 24252, Republic of Korea
- Institute of Clinical Dentistry, Hallym University, Chuncheon 24252, Republic of Korea
| | - Yoo-Sung Nam
- Department of Oral and Maxillofacial Surgery, Hallym University Sacred Heart Hospital, Anyang 14066, Republic of Korea
- Graduate School of Clinical Dentistry, Hallym University, Chuncheon 24252, Republic of Korea
- Institute of Clinical Dentistry, Hallym University, Chuncheon 24252, Republic of Korea
| | - In-Young Park
- Graduate School of Clinical Dentistry, Hallym University, Chuncheon 24252, Republic of Korea
- Institute of Clinical Dentistry, Hallym University, Chuncheon 24252, Republic of Korea
| | - Sung-Woon On
- Graduate School of Clinical Dentistry, Hallym University, Chuncheon 24252, Republic of Korea
- Institute of Clinical Dentistry, Hallym University, Chuncheon 24252, Republic of Korea
- Division of Oral and Maxillofacial Surgery, Department of Dentistry, Hallym University Dongtan Sacred Heart Hospital, Hwaseong 18450, Republic of Korea
| | - Jong-Cheol Kim
- Department of Oral and Maxillofacial Surgery, Hallym University Sacred Heart Hospital, Anyang 14066, Republic of Korea
- Mir Dental Hospital, Daegu 41940, Republic of Korea
| | - Byoung-Eun Yang
- Department of Oral and Maxillofacial Surgery, Hallym University Sacred Heart Hospital, Anyang 14066, Republic of Korea
- Graduate School of Clinical Dentistry, Hallym University, Chuncheon 24252, Republic of Korea
- Institute of Clinical Dentistry, Hallym University, Chuncheon 24252, Republic of Korea
| |
Collapse
|
13
|
Cascos R, Ortiz Del Amo L, Álvarez-Guzmán F, Antonaya-Martín JL, Celemín-Viñuela A, Gómez-Costa D, Zafra-Vallejo M, Agustín-Panadero R, Gómez-Polo M. Accuracy between 2D Photography and Dual-Structured Light 3D Facial Scanner for Facial Anthropometry: A Clinical Study. J Clin Med 2023; 12:jcm12093090. [PMID: 37176531 PMCID: PMC10179155 DOI: 10.3390/jcm12093090] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2023] [Revised: 04/18/2023] [Accepted: 04/21/2023] [Indexed: 05/15/2023] Open
Abstract
(1) Background: Facial scanners are used in different fields of dentistry to digitalize the soft tissues of the patient's face. The development of technology has allowed the patient to have a 3-dimensional virtual representation, facilitating facial integration in the diagnosis and treatment plan. However, the accuracy of the facial scanner and the obtaining of better results with respect to the manual or two-dimensional (2D) method are questionable. The objective of this clinical trial was to evaluate the usefulness and accuracy of the 3D method (a dual-structured light facial scanner) and compare it with the 2D method (photography) to obtain facial analysis in the maximum intercuspation position and smile position. (2) Methods: A total of 60 participants were included, and nine facial landmarks and five interlandmarks distances were determined by two independent calibrated operators for each participant. All measurements were made using three methods: the manual method (manual measurement), the 2D method (photography), and the 3D method (facial scanner). All clinical and lighting conditions, as well as the specific parameters of each method, were standardized and controlled. The facial interlandmark distances were made by using a digital caliper, a 2D software program (Adobe Photoshop, version 21.0.2), and a 3D software program (Meshlab, version 2020.12), respectively. The data were analyzed by SPSS statistical software. The Kolmogorov-Smirnov test revealed that trueness and precision values were normally distributed (p > 0.05), so a Student's t-test was employed. (3) Results: Statistically significant differences (p ≤ 0.01) were observed in all interlandmark measurements in the 2D group (photography) to compare with the manual group. The 2D method obtained a mean accuracy value of 2.09 (±3.38) and 2.494 (±3.67) in maximum intercuspation and smile, respectively. On the other hand, the 3D method (facial scanner) obtained a mean accuracy value of 0.61 (±1.65) and 0.28 (±2.03) in maximum intercuspation and smile, respectively. There were no statistically significant differences with the manual method. (4) Conclusions: The employed technique demonstrated that it influences the accuracy of facial records. The 3D method reported acceptable accuracy values, while the 2D method showed discrepancies over the clinically acceptable limits.
Collapse
Affiliation(s)
- Rocío Cascos
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain
- Department of Nursing and Estomatology, Faculty of Health Sciences, Rey Juan Carlos University, 28922 Madrid, Spain
| | - Laura Ortiz Del Amo
- Department of Nursing and Estomatology, Faculty of Health Sciences, Rey Juan Carlos University, 28922 Madrid, Spain
| | - Francisco Álvarez-Guzmán
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain
| | - José Luis Antonaya-Martín
- Department of Nursing and Estomatology, Faculty of Health Sciences, Rey Juan Carlos University, 28922 Madrid, Spain
| | - Alicia Celemín-Viñuela
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain
| | - Diego Gómez-Costa
- Department of Nursing and Estomatology, Faculty of Health Sciences, Rey Juan Carlos University, 28922 Madrid, Spain
| | - Mónica Zafra-Vallejo
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain
| | - Rubén Agustín-Panadero
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain
| | - Miguel Gómez-Polo
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain
| |
Collapse
|
14
|
Comparison Study of Extraction Accuracy of 3D Facial Anatomical Landmarks Based on Non-Rigid Registration of Face Template. Diagnostics (Basel) 2023; 13:diagnostics13061086. [PMID: 36980394 PMCID: PMC10047049 DOI: 10.3390/diagnostics13061086] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 03/03/2023] [Accepted: 03/06/2023] [Indexed: 03/15/2023] Open
Abstract
(1) Background: Three-dimensional (3D) facial anatomical landmarks are the premise and foundation of facial morphology analysis. At present, there is no ideal automatic determination method for 3D facial anatomical landmarks. This research aims to realize the automatic determination of 3D facial anatomical landmarks based on the non-rigid registration algorithm developed by our research team and to evaluate its landmark localization accuracy. (2) Methods: A 3D facial scanner, Face Scan, was used to collect 3D facial data of 20 adult males without significant facial deformities. Using the radial basis function optimized non-rigid registration algorithm, TH-OCR, developed by our research team (experimental group: TH group) and the non-rigid registration algorithm, MeshMonk (control group: MM group), a 3D face template constructed in our previous research was deformed and registered to each participant’s data. The automatic determination of 3D facial anatomical landmarks was realized according to the index of 32 facial anatomical landmarks determined on the 3D face template. Considering these 32 facial anatomical landmarks manually selected by experts on the 3D facial data as the gold standard, the distance between the automatically determined and the corresponding manually selected facial anatomical landmarks was calculated as the “landmark localization error” to evaluate the effect and feasibility of the automatic determination method (template method). (3) Results: The mean landmark localization error of all facial anatomical landmarks in the TH and MM groups was 2.34 ± 1.76 mm and 2.16 ± 1.97 mm, respectively. The automatic determination of the anatomical landmarks in the middle face was better than that in the upper and lower face in both groups. Further, the automatic determination of anatomical landmarks in the center of the face was better than in the marginal part. (4) Conclusions: In this study, the automatic determination of 3D facial anatomical landmarks was realized based on non-rigid registration algorithms. There is no significant difference in the automatic landmark localization accuracy between the TH-OCR algorithm and the MeshMonk algorithm, and both can meet the needs of oral clinical applications to a certain extent.
Collapse
|
15
|
Xiao Z, Chen G, Zhao Y, Wang Y, Gu Y. Perceptual difference of smile aesthetics between 2-dimensional photographs and 3-dimensional dentofacial images: a cross-sectional study. BMC Oral Health 2023; 23:104. [PMID: 36797718 PMCID: PMC9933254 DOI: 10.1186/s12903-023-02798-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Accepted: 02/08/2023] [Indexed: 02/18/2023] Open
Abstract
BACKGROUND The aim of this study was to compare the perceptual difference of smile aesthetics between 2D photographs and 3D dentofacial images as perceived by orthodontists and graduate students. METHODS Forty-eight subjects finished orthodontic treatment were recruited with 2D photographs of frontal, oblique and lateral views as well as 3D dentofacial images. Twelve senior orthodontists and 13 postgraduate students were asked to rate the 2D and 3D smile simulations based on visual analog scale (VAS) and to vote for smile features that affect the attractiveness of smile. At the end, they completed a questionnaire about their views on different smile simulations. Wilcoxon signed-rank, Bland-Altman analysis, and multiple linear regression were used to compare the ratings and votes of smile perception between raters and between records. RESULTS Orthodontists and postgraduate students rated smile consistently with 2D photographs, while orthodontists tended to give a higher rate for unattractive smiles and a lower rate for attractive smiles with 3D dentofacial images. The 3D dentofacial images were rated significantly lower than 2D photographs and the voting of most of the smile features showed significant negative main effect on VAS scores, while the effect of demographic characteristics of raters, voting on visible width of upper dentition and buccal corridor was not significant. In addition, a significant negative main effect of commissure and facial profile was found on the rating discrepancy between 2D and 3D images. CONCLUSIONS Senior orthodontists tend to perceived 3D images more conservatively in smile evaluation. 3D dentofacial images were rated lower than 2D photographs and most of the smile features affect the aesthetic perception of smile. The perceptual difference of commissure and facial profile contributed to the lower ratings in 3D dentofacial images.
Collapse
Affiliation(s)
- Zhuoxing Xiao
- grid.11135.370000 0001 2256 9319National Center for Stomatology & National Clinical Research Center for Oral Disease & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology, Key Laboratory of Digital Stomatology & Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health & NMPA Key Laboratory for Dental Materials, Department of Orthodontics, Peking University School and Hospital of Stomatology, No. 22 Zhongguancun South Avenue, Haidian District, Beijing, 100081 People’s Republic of China
| | - Gui Chen
- grid.11135.370000 0001 2256 9319National Center for Stomatology & National Clinical Research Center for Oral Disease & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology, Key Laboratory of Digital Stomatology & Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health & NMPA Key Laboratory for Dental Materials, Department of Orthodontics, Peking University School and Hospital of Stomatology, No. 22 Zhongguancun South Avenue, Haidian District, Beijing, 100081 People’s Republic of China
| | - Yijiao Zhao
- grid.11135.370000 0001 2256 9319National Center for Stomatology & National Clinical Research Center for Oral Disease % National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology, Key Laboratory of Digital Stomatology & Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health & NMPA Key Laboratory for Dental Materials, Center of Digital Dentistry, Peking University School and Hospital of Stomatology, No. 22 Zhongguancun South Avenue, Haidian District, Beijing, 100081 People’s Republic of China
| | - Yong Wang
- grid.11135.370000 0001 2256 9319National Center for Stomatology & National Clinical Research Center for Oral Disease % National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology, Key Laboratory of Digital Stomatology & Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health & NMPA Key Laboratory for Dental Materials, Center of Digital Dentistry, Peking University School and Hospital of Stomatology, No. 22 Zhongguancun South Avenue, Haidian District, Beijing, 100081 People’s Republic of China
| | - Yan Gu
- National Center for Stomatology & National Clinical Research Center for Oral Disease & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology, Key Laboratory of Digital Stomatology & Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health & NMPA Key Laboratory for Dental Materials, Department of Orthodontics, Peking University School and Hospital of Stomatology, No. 22 Zhongguancun South Avenue, Haidian District, Beijing, 100081, People's Republic of China.
| |
Collapse
|
16
|
Cao R, Chen B, Xu H, Cai Y, Liu W. Accuracy of three-dimensional optical devices for facial soft-tissue measurement in clinical practice of stomatology: A PRISMA systematic review. Medicine (Baltimore) 2022; 101:e31922. [PMID: 36451461 PMCID: PMC9704975 DOI: 10.1097/md.0000000000031922] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Accepted: 10/31/2022] [Indexed: 12/02/2022] Open
Abstract
BACKGROUND The accuracy of 3-dimensional (3D) optical devices for facial soft-tissue measurement is essential to the success of clinical treatment in stomatology. The aim of the present systematic review was to summarize the accuracy of 3D optical devices used for facial soft-tissue assessment in stomatology. METHODS An extensive systematic literature search was performed in the PubMed/MEDLINE, Embase, Scopus and Cochrane Library databases for studies published in the English language up to May 2022 in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. Peer-reviewed journal articles evaluating the facial soft-tissue morphology by 3D optical devices were included. The risk of bias was performed using the Quality Assessment Tool for Diagnostic Accuracy Studies-2 guidelines by the 2 reviewers. The potential publication bias was analyzed using the Review Manager software. RESULTS The query returned 1853 results. A total of 38 studies were included in this review. Articles were categorized based on the principle of devices: laser-based scanning, structured-light scanning, stereophotogrammetry and red, green, blue-depth camera. CONCLUSION Overall, the 3D optical devices demonstrated excellent accuracy and reliability for facial soft-tissue measurement in stomatology. red, green, blue-depth camera can collect accurate static and dynamic 3D facial scans with low cost and high measurement accuracy. Practical needs and availability of resources should be considered when these devices are used in clinical settings.
Collapse
Affiliation(s)
- Rongkai Cao
- School and Hospital of Stomatology, Tongji University, Shanghai Engineering Research Center of Tooth Restoration and Regeneration, Shanghai, China
| | - Beibei Chen
- School and Hospital of Stomatology, Tongji University, Shanghai Engineering Research Center of Tooth Restoration and Regeneration, Shanghai, China
| | - Hui Xu
- School and Hospital of Stomatology, Tongji University, Shanghai Engineering Research Center of Tooth Restoration and Regeneration, Shanghai, China
| | - Yiyi Cai
- School and Hospital of Stomatology, Tongji University, Shanghai Engineering Research Center of Tooth Restoration and Regeneration, Shanghai, China
| | - Weicai Liu
- School and Hospital of Stomatology, Tongji University, Shanghai Engineering Research Center of Tooth Restoration and Regeneration, Shanghai, China
| |
Collapse
|
17
|
Facial Scanning Accuracy with Stereophotogrammetry and Smartphone Technology in Children: A Systematic Review. CHILDREN 2022; 9:children9091390. [PMID: 36138698 PMCID: PMC9498045 DOI: 10.3390/children9091390] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/29/2022] [Revised: 09/03/2022] [Accepted: 09/12/2022] [Indexed: 12/23/2022]
Abstract
The aim of the study was to systematically review and compare the accuracy of smartphone scanners versus stereophotogrammetry technology for facial digitization in children. A systematic literature search strategy of articles published from 1 January 2010 to 30 August 2022 was adopted through a combination of Mesh terms and free text words pooled through boolean operators on the following databases: PubMed, Scopus, Web of Science, Cochrane Library, LILACS, and OpenGrey. Twenty-three articles met the inclusion criteria. Stationary stereophotogrammetry devices showed a mean accuracy that ranged from 0.087 to 0.860 mm, portable stereophotogrammetry scanners from 0.150 to 0.849 mm, and smartphones from 0.460 to 1.400 mm. Regarding the risk of bias assessment, fourteen papers showed an overall low risk, three articles had unclear risk and four articles had high risk. Although smartphones showed less performance on deep and irregular surfaces, all the analyzed devices were sufficiently accurate for clinical application. Internal depth-sensing cameras or external infrared structured-light depth-sensing cameras plugged into smartphones/tablets increased the accuracy. These devices are portable and inexpensive but require greater operator experience and patient compliance for the incremented time of acquisition. Stationary stereophotogrammetry is the gold standard for greater accuracy and shorter acquisition time, avoiding motion artifacts.
Collapse
|
18
|
Effect of Ambient Lights on the Accuracy of a 3-Dimensional Optical Scanner for Face Scans: An In Vitro Study. JOURNAL OF HEALTHCARE ENGINEERING 2022; 2022:2637078. [PMID: 36032545 PMCID: PMC9400401 DOI: 10.1155/2022/2637078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/23/2022] [Accepted: 07/15/2022] [Indexed: 11/21/2022]
Abstract
Most 3D scanners use optical technology that is impacted by lighting conditions, especially in triangulation with structured-light or laser techniques. However, the effect of ambient lights on the accuracy of the face scans remains unclear. The purpose of this study is to investigate the effect of ambient lights on the accuracy of the face scans obtained from the face scanner (EinScan Pro 2X Plus, Shining 3D Tech. Co., LTD., Hangzhou, China). A head model was designed in Rhinoceros 5 software (Rhino, Robert McNeel and Associates for Windows, Washington DC, USA) and printed with 200 micron resolution of polylactic acid and was dented with 2.0 mm of carbide bur to aid in superimposition in software. The head model was measured by a coordinate-measuring machine (CMM) to generate a reference stereolithography (STL) file as a control. The face model was scanned four times under nine light conditions: cool white (CW), warm white (WW), daylight (DL), natural light (NL), and illuminant (9w, 18w, 22w). Scan data were exported into an STL file. The scan STL files obtained were compared with the reference STL file by 3D inspection software (Geomagic Control X version 17, Geomagic, Morrisville, NC, USA). The deviations and root mean square errors (RMSEs) between the reference model (trueness) and within the group (precision) were selected for the statistical analysis. The statistical analysis was done using SPSS 20.0 (IBM Company, Chicago, USA). The trueness and precision were evaluated with the one-way ANOVA with multiple comparisons using the Tukey method. For trueness, the scanner showed the lowest RMSE under the NL group (77.18 ± 3.22) and the highest RMSE under the 18w-DL group (95.33 ± 6.89). There was a statistically significant difference between the NL group and the 18w-DL group (p < 0.05) for trueness. Similarly, for precision, the scanner showed the lowest RMSE under the NL group (56.92 ± 4.56) and the highest RMSE under the 9w-CW group (78.52 ± 10.61). There was statistically significant difference between NL, 18w-WW, 18w-CW, 18w-DL, 22w-WW, 22w-DL, 9w-CW, 9w-WW, and 9w-DL (p < 0.05) for the precision. Ambient lights affected the face scans. Under the natural light condition, the face scanner had the best accuracy in terms of both trueness and precision. The 18w-DL and 9w-WW conditions showed the least trueness whereasthe 9w-CW and 9w-DL conditions showed the least precision.
Collapse
|
19
|
Portable three-dimensional imaging to monitor small volume enhancement in face, vulva, and hand: A comparative study. J Plast Reconstr Aesthet Surg 2022; 75:3574-3585. [PMID: 35659734 DOI: 10.1016/j.bjps.2022.04.042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Revised: 03/21/2022] [Accepted: 04/12/2022] [Indexed: 11/23/2022]
Abstract
Multiple handheld three-dimensional (3D) systems are available on the market, but data regarding their use in detecting small volumes are limited. The aim of this study was to compare different portable 3D technologies in detecting small volumetric enhancement on a mannequin model and a series of patients. Five portable 3D systems (Artec Eva, Crisalix, Go!Scan, LifeViz Mini, and Vectra H1) were tested in a controlled environment with standardised volumes and in a clinical setting with patients undergoing small volume fat grafting to face, vulva, and hand. Accuracy was assessed with absolute and relative technical error measurement (TEM and rTEM); precision with intra- and inter-observer reliability (rp and ICC); and usability in clinical practice with the following parameters: portability, suitability of use in operating theatre/clinic, ease of use of hardware and software, speed of capture, image quality, patient comfort, and cost. All tested devices presented overall good accuracy in detecting small volumetric changes ranging from 0.5 to 4 cc. Structured-light laser scanners (Artec Eva and Go!Scan) showed high accuracy, but their use in clinical practice was limited by longer capture time, multiple wiring, and complex software for analysis. Crisalix was considered the most user-friendly, less bothering for patients, and truly portable, but its use was limited to the face because the software does not include vulva and hand. Three-dimensional technologies exploiting the principle of passive stereophotogrammetry such as LifeViz Mini and Vectra H1 were the most versatile for assessing accurately multiple body areas, representing overall the best long-term value for money. Therefore, 3D portable technology is a non-invasive, accurate, and reproducible method to assess the volumetric outcome after facial, vulval, and hand injectables. The choice of the 3D system should be based on the clinical need and resources available.
Collapse
|
20
|
Wang XW, Liu ZJ, Diao J, Zhao YJ, Jiang JH. Morphologic reproducibility in 6 regions of the 3-dimensional facial models acquired by a standardized procedure: An in vivo study. Am J Orthod Dentofacial Orthop 2021; 161:e287-e295. [PMID: 34924284 DOI: 10.1016/j.ajodo.2020.11.042] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2020] [Revised: 11/01/2020] [Accepted: 11/01/2020] [Indexed: 11/01/2022]
Abstract
INTRODUCTION A standardized procedure was proposed to control involuntary motion and other factors during the capture of structural light scanning that could influence the morphology of 3-dimensional facial models; interoperator reproducibility was evaluated. METHODS Twenty subjects volunteered for facial scanning. Three researchers scanned each volunteer 3 times on the same day using the FaceScan structural light scanning system (Isravision, Darmstadt, Germany) and after the proposed procedure. Captures were done at 5-minute intervals. The 3 facial scans acquired by the same researcher were compared by reverse engineering software (Geomagic; 3D Systems, Rock Hill, SC). Six facial regions, including forehead, nose, paranasal, upper lip, lower lip and chin, and cheek, were divided. With the first scan as a reference, the other 2 scans were registered, and surface-to-surface distance maps were acquired to calculate the mean, standard deviation, and root mean squares (RMS) between 2 surfaces. The reproducibility between 3 researchers was then evaluated by a 1-way analysis of variance. RESULTS The mean of 6 facial regions was close to 0. The RMS of lip regions were largest (0.48-0.53 mm), the forehead was smallest (0.21 mm), and the others ranged 0.37 mm to 0.42 mm. The standard deviation was slightly smaller than RMS and had the same trend of change. There was no significant difference in RMS among the 3 researchers (P >0.05). CONCLUSIONS With the constraint of the standardized procedure, the morphologic reproducibility of facial models in 6 regions was satisfying.
Collapse
Affiliation(s)
- Xin-Wen Wang
- Department of Orthodontics, Peking University School and Hospital of Stomatology, Beijing, China
| | - Zi-Jin Liu
- Department of Orthodontics, Peking University School and Hospital of Stomatology, Beijing, China
| | - Jing Diao
- Department of Preventive Medicine, Peking University School and Hospital of Stomatology, Beijing, China
| | - Yi-Jiao Zhao
- National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing, China
| | - Jiu-Hui Jiang
- Department of Orthodontics, Peking University School and Hospital of Stomatology, Beijing, China.
| |
Collapse
|
21
|
Bermejo E, Taniguchi K, Ogawa Y, Martos R, Valsecchi A, Mesejo P, Ibáñez O, Imaizumi K. Automatic landmark annotation in 3D surface scans of skulls: Methodological proposal and reliability study. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2021; 210:106380. [PMID: 34478914 DOI: 10.1016/j.cmpb.2021.106380] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Accepted: 08/22/2021] [Indexed: 05/09/2023]
Abstract
BACKGROUND AND OBJECTIVES Craniometric landmarks are essential in many biomedical applications, such as morphometric analysis or forensic identification. The process of locating landmarks is usually a manual and slow task, highly influenced by fatigue, skills and the experience of the practitioner. Localization errors are propagated and magnified in subsequent steps, which can result in incorrect measurements or assumptions. Thereby, standardization, reliability and reproducibility lay the foundations for the necessary accuracy in subsequent measurements or anatomical analysis. In this paper, we present an automatic method to annotate 3D surface skull models taking into account anatomical and geometrical features. METHODS The proposed method follows a hybrid structure where a deformable template is used to initialize the landmark positions. Then, a refinement stage is applied using prior anatomical knowledge to ensure a correct placement. Our proposal is validated over thirty 3D skull scans of male Caucasians, acquired by hand-held surface scanning, and a set of 58 craniometric landmarks. A statistical analysis was carried out to analyze the inter- and intra-observer variability of manual annotations and the automatic results, along with a visual assessment of the final results. RESULTS Inter-observer errors show significant differences, which are reflected in the expert consensus used as reference. The average localization error was 2.19±1.5 mm when comparing the automatic landmarks to the reference location. The subsequent visual analysis confirmed the reliability of the refinement method for most landmarks. CONCLUSIONS Repeated manual annotations show a high variability depending on both skills and expertise of the observer, and landmarks' location and characteristics. In contrast, the automatic method provides an accurate, robust and reproducible alternative to the tedious and error-prone task of manual landmarking.
Collapse
Affiliation(s)
- Enrique Bermejo
- Second Forensic Biology Section, National Research Institute of Police Science, Chiba 277-0882, Japan; Andalusian Research Institute in Data Science and Computational Intelligence (DaSCI), University of Granada, Granada 18071, Spain.
| | - Kei Taniguchi
- Second Forensic Biology Section, National Research Institute of Police Science, Chiba 277-0882, Japan
| | - Yoshinori Ogawa
- Second Forensic Biology Section, National Research Institute of Police Science, Chiba 277-0882, Japan
| | - Rubén Martos
- Physical Anthropology Lab, Dpt. of Legal Medicine, Toxicology and Physical Anthropology, University of Granada, Granada 18071, Spain
| | - Andrea Valsecchi
- Panacea Cooperative Research S. Coop., Ponferrada 24402, Spain; Andalusian Research Institute in Data Science and Computational Intelligence (DaSCI), University of Granada, Granada 18071, Spain
| | - Pablo Mesejo
- Panacea Cooperative Research S. Coop., Ponferrada 24402, Spain; Andalusian Research Institute in Data Science and Computational Intelligence (DaSCI), University of Granada, Granada 18071, Spain
| | - Oscar Ibáñez
- Panacea Cooperative Research S. Coop., Ponferrada 24402, Spain; Andalusian Research Institute in Data Science and Computational Intelligence (DaSCI), University of Granada, Granada 18071, Spain
| | - Kazuhiko Imaizumi
- Second Forensic Biology Section, National Research Institute of Police Science, Chiba 277-0882, Japan
| |
Collapse
|
22
|
Akan B, Gökçe G, Şahan AO, Veli İ. Tooth-borne versus tooth-bone-borne rapid maxillary expanders according to a stereophotogrammetric evaluation of facial soft tissues: A randomized clinical trial. Orthod Craniofac Res 2021; 24:438-448. [PMID: 34105880 DOI: 10.1111/ocr.12509] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2021] [Revised: 05/15/2021] [Accepted: 06/03/2021] [Indexed: 11/29/2022]
Abstract
OBJECTIVES To evaluate the effects of tooth-borne and tooth-bone-borne rapid maxillary expansion (RME) on soft tissue with stereophotogrammetry. SETTING AND SAMPLE POPULATION Thirty two patients (15 males and 17 females) who met inclusion criteria were divided into two groups. In the first group, tooth-borne RME appliance (hyrax) was applied to 16 patients (9 males and 7 females mean age 13.4 ± 1.3 years), and in the second group, tooth-bone-borne RME appliance (hybrid hyrax) was applied to 16 patients (6 males and 10 females, mean age 13.05 ± 1.24 years). MATERIALS AND METHODS Changes in soft tissues before RME (T0) and post-retention (T1) period were evaluated by stereophotogrammetry. Linear and angular measurements were performed. Independent- and dependent-sample t tests were used to compare intra- and inter-group differences at P < .05 significance level. RESULTS The data revealed statistically significant changes in nasal width, mid-face width, upper lip vermillion length/lower lip vermillion length ratio and upper lip angle in hyrax group. (P < .05) Also nasal width, lower lip length, lower lip vermillion length, anterior face height, lower face height, convexity angle and mandibular angle showed statistically significant changes in hybrid hyrax group. (P < .05) In the inter-group evaluation, no significant differences were found except upper lip and mandible angle. (P < .05). CONCLUSION Both hyrax and hybrid hyrax expanders had effects on soft tissue profile. Anterior face height and lower face height increased in both groups. Upper lip length increased by 0.36 mm in the hybrid group and 0.10 mm in the hyrax group. TRIAL REGISTRATION This trial was registered at Clinicaltrials.gov (Identifier: NCT04828213).
Collapse
Affiliation(s)
- Burçin Akan
- Department of Orthodontics, Faculty of Dentistry, Izmir Katip Celebi University, Izmir, Turkey
| | - Gökçenur Gökçe
- Department of Orthodontics, Faculty of Dentistry, Izmir Katip Celebi University, Izmir, Turkey
| | | | - İlknur Veli
- Department of Orthodontics, Izmir Katip Celebi University, Izmir, Turkey
| |
Collapse
|
23
|
Nightingale RC, Ross MT, Cruz RLJ, Allenby MC, Powell SK, Woodruff MA. Frugal 3D scanning using smartphones provides an accessible framework for capturing the external ear. J Plast Reconstr Aesthet Surg 2021; 74:3066-3072. [PMID: 34088646 DOI: 10.1016/j.bjps.2021.03.131] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Revised: 02/07/2021] [Accepted: 03/13/2021] [Indexed: 11/25/2022]
Abstract
Three-dimensional (3D) scanning technologies, such as medical imaging and surface scanning, have important applications for capturing patient anatomy to create personalised prosthetics. Digital approaches for capturing anatomical detail as opposed to traditional, invasive impression techniques significantly reduces turnaround times and lower production costs while still maintaining the high aesthetic quality of the end product. While previous case studies utilise expensive 3D scanning and modelling frameworks, their clinical translation is limited due to high equipment costs. In this study, we develop and validate a low-cost framework for clinical 3D scanning of the external ear using photogrammetry and a smartphone camera. We recruited five novice operators who watched an instructional video before scanning 20 healthy adult participant ears who did not have microtia. Our results show that the smartphone-based photogrammetry methodology produces 3D scans of the external ear that were accurate to (1.5 ± 0.4) mm and were (71 ± 14) % complete compared with those from a gold standard reference scanner, with no significant difference observed between operators. A moderate to strong interrater reliability was determined for all novice operators, suggesting that all novice operators were able to capture repeatable scans. The development of this smartphone photogrammetry approach has the potential to provide a non-invasive, inexpensive and accessible means to capture patient morphology for use in clinical assessment and personalised device manufacture, specifically for ear prostheses. We also demonstrate that inexperienced operators can rapidly learn and apply smartphone photogrammetry for accurate and reliable scans of the external ear with important applications for future clinical translation.
Collapse
Affiliation(s)
- Renee C Nightingale
- Queensland University of Technology (QUT), Brisbane, Queensland, 4000, Australia
| | - Maureen T Ross
- Queensland University of Technology (QUT), Brisbane, Queensland, 4000, Australia
| | - Rena L J Cruz
- Queensland University of Technology (QUT), Brisbane, Queensland, 4000, Australia
| | - Mark C Allenby
- Queensland University of Technology (QUT), Brisbane, Queensland, 4000, Australia
| | - Sean K Powell
- Queensland University of Technology (QUT), Brisbane, Queensland, 4000, Australia.
| | - Maria A Woodruff
- Queensland University of Technology (QUT), Brisbane, Queensland, 4000, Australia
| |
Collapse
|
24
|
Revilla-León M, Pérez-Barquero JA, Barmak BA, Agustín-Panadero R, Fernández-Estevan L, Att W. Facial scanning accuracy depending on the alignment algorithm and digitized surface area location: An in vitro study. J Dent 2021; 110:103680. [PMID: 33901605 DOI: 10.1016/j.jdent.2021.103680] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2021] [Revised: 04/16/2021] [Accepted: 04/19/2021] [Indexed: 11/26/2022] Open
Abstract
OBJECTIVES To measure the accuracy (trueness and precision) of a facial scanner depending on the alignment method and the digitized surface area location. METHODS Fourteen markers were adhered on a head mannequin and digitized using an industrial scanner (GOM Atos Q 3D 12 M; Carl Zeiss Industrielle Messtechnik GmbH). A control mesh was acquired. Subsequently, the mannequin was digitized using a facial scanner (Arc4; Bellus3D) (n = 30). The control mesh was delineated into 10 areas. Based on the alignment procedures, two groups were created: reference best fit (RBF group) and landmark-based best fit (LA group). The root mean square was used to calculate the discrepancy between the control mesh and each facial scan. A 2-way ANOVA and Tukey pairwise comparison tests were used to compare trueness and precision between the 2 groups across 10 areas (α = .05). RESULTS Both alignment algorithms (P = .007) and digitized area (P < .001) were significant predictors of trueness with a significant interaction between the two predictors (F (9, 580) =25.13, P < .001). Tukey pairwise comparison showed that there was a significant difference between mean trueness values of RBF (mean=0.53 mm) and LA (mean=0.55 mm) groups. Moreover, a significant difference was detected among the trueness values across surface areas. The A9-area (left tragus area) had the highest and A5-area (right cheek area) had the lowest mean trueness. Both alignment algorithm (P < .001) and digitized surface area (P < .001) were significant predictors of precision with a significant interaction between the two predictors (F (9, 580) =14.34, P < .001). Tukey pairwise comparison showed that there was a significant difference between mean precision values of RBF (mean=0.38 mm) and LA (mean=0.35 mm) groups. Moreover, a significant difference was detected among the precision values across surface areas. Comparing the surface areas, A9-area had the highest and A10-area (forehead area) had the lowest mean precision. CONCLUSIONS Alignment procedures influenced on the scanning trueness and precision mean values, but the facial scanner accuracy values obtained were within the clinically acceptable accuracy threshold of less or equal than 2 mm. Furthermore, the scanning accuracy (for both trueness and precision) depended on the location of the scanned surface area, being more accurate on the middle of the face than on the sides of the face.
Collapse
Affiliation(s)
- Marta Revilla-León
- Comprehensive Dentistry Department, College of Dentistry, Texas A&M University, Dallas, TX, United States; Affiliate Faculty Graduate Prosthodontics, Restorative Dentistry Department, School of Dentistry, University of Washington, Seattle, WA, United States; Researcher at Revilla Research Center, Madrid, Spain.
| | | | - Basir A Barmak
- Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, NY, United States
| | - Rubén Agustín-Panadero
- Department of Dental Medicine, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain
| | - Lucía Fernández-Estevan
- Department of Dental Medicine, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain
| | - Wael Att
- Department of Prosthodontics, Tuff University School of Dental Medicine, Boston, MA, United States
| |
Collapse
|
25
|
Three-Dimensional Reproducibility of the Soft Tissue Landmarks Taken by Structured-Light Facial Scanner in Accordance with the Head Position Change. Healthcare (Basel) 2021; 9:healthcare9040428. [PMID: 33917171 PMCID: PMC8067862 DOI: 10.3390/healthcare9040428] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2021] [Revised: 03/31/2021] [Accepted: 04/05/2021] [Indexed: 11/16/2022] Open
Abstract
The aim of this study was to evaluate the three-dimensional reproducibility of the structured-light facial scanner according to the head position change. A mannequin head was used and angle of the mannequin’s axis-orbital plane to the true horizontal plane was adjusted to +10, +5, 0, −5, and −10°. Facial scanning was conducted 30 times, respectively, and 150 3D images were obtained. Reoriented landmarks of each group were compared and analyzed. Reproducibility decreased as the distance from the facial center increased. Additionally, the landmarks below showed lower reproducibility and higher dispersion than landmarks above. These differences occurred mainly in the anteroposterior direction as opposed to other directions. Positive inclination of the head position showed superior reproducibility compared to a negative inclination. This study showed that reproducibility of a structured-light scanner could be varied depending on the head position. Inaccuracies of landmarks in the anteroposterior direction are greater than in other directions. This means that evaluations of the profile using a structured-light scanner should be made carefully. Therefore, the proper head position should be set to ensure the accuracy of the image.
Collapse
|
26
|
Accuracy of a patient 3-dimensional virtual representation obtained from the superimposition of facial and intraoral scans guided by extraoral and intraoral scan body systems. J Prosthet Dent 2021; 128:984-993. [PMID: 33838919 DOI: 10.1016/j.prosdent.2021.02.023] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2020] [Revised: 02/17/2021] [Accepted: 02/17/2021] [Indexed: 11/22/2022]
Abstract
STATEMENT OF PROBLEM A patient 3-dimensional virtual representation aims to facilitate the integration of facial references into treatment planning or prosthesis design procedures, but the accuracy of the virtual patient representation remains unclear. PURPOSE The purpose of the present observational clinical study was to determine and compare the accuracy (trueness and precision) of a virtual patient obtained from the superimposition procedures of facial and intraoral digital scans guided by 2 scan body systems. MATERIAL AND METHODS Ten participants were recruited. An intraoral digital scan was completed (TRIOS 4). Four fiduciary markers were placed in the glabella (Gb), left (IOL) and right infraorbital canal (IOR), and tip of the nose (TN). Two digitizing procedures were completed: cone beam computed tomography (CBCT) (i-CAT FLX V-Series) and facial scans (Face Camera Pro Bellus) with 2 different scan body systems: AFT (ScanBodyFace) and Sat 3D (Sat 3D). For the AFT system, a reference facial scan was obtained, followed by a facial scan with the participant in the same position as when capturing the CBCT scan. For the Sat 3D system, a reference facial scan was recorded, followed by a facial scan with the patient in the same position as when capturing the CBCT scan. The patient 3-dimensional representation for each scan body system was obtained by using a computer program (Matera 2.4). A total of 14 interlandmark distances were measured in the CBCT scan and both 3-dimensional patient representations. The discrepancies between the CBCT scan (considered the standard) and each 3-dimensional representation of each patient were used to analyze the data. The Kolmogorov-Smirnov test revealed that trueness and precision values were not normally distributed (P<.05). A log10 transformation was performed with 1-way repeated-measures MANOVA (α=.05). RESULTS The accuracy of the virtual 3-dimensional patient representations obtained by using AFT and Sat 3D systems showed a trueness ranging from 0.50 to 1.64 mm and a precision ranging from 0.04 to 0.14 mm. The Wilks lambda detected an overall significant difference in the accuracy values between the AFT and Sat 3D systems (F=3628.041, df=14, P<.001). A significant difference was found in 12 of the 14 interlandmark measurements (P<.05). The AFT system presented significantly higher discrepancy values in Gb-IOL, TN-IOR, IOL-IOR, and TN-6 (P<.05) than in the Sat 3D system. The Sat 3D system had a significantly higher discrepancy in Gb-TN, TN-IOL, IOL-3, IOL-6, TN-8, TN-9, TN-11, IOR-11, and IOR-14 (P<.05) than in the AFT system. The Wilcoxon signed-rank test did not detect any significant difference in the precision values between the AFT and Sat 3D systems (Z=-0.838, P=.402). CONCLUSIONS The accuracy of the patient 3-dimensional virtual representations obtained using AFT and Sat 3D systems showed trueness values ranging from 0.50 to 1.64 mm and precision values ranging from 0.04 to 0.14 mm. The AFT system obtained higher trueness than the Sat 3D system, but both systems showed similar precision values.
Collapse
|
27
|
Evaluation of the Soft Tissue Changes after Rapid Maxillary Expansion Using a Handheld Three-Dimensional Scanner: A Prospective Study. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph18073379. [PMID: 33805172 PMCID: PMC8036493 DOI: 10.3390/ijerph18073379] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/07/2021] [Revised: 03/20/2021] [Accepted: 03/22/2021] [Indexed: 11/17/2022]
Abstract
Facial soft tissue esthetics is a priority in orthodontic treatment, and emerging of the digital technologies can offer new methods to help the orthodontist toward an esthetic outcome. This prospective study aimed to assess the soft tissue changes of the face after six months of retention following Rapid Maxillary Expansion (RME). The sample consisted of 25 patients (13 females, 12 males, mean age: 11.6 years) who presented with unilateral or bilateral posterior crossbite requiring RME, which was performed with a Hyrax expander. 3D facial images were obtained before treatment (T0) and at the end of a six-month retention period after the treatment (T1) using a structured-light 3D handheld scanner. Linear and angular measurements were performed and 3D deviation analyses were done for six morphological regions of the face. Significant changes in various areas of the nasal and the upper lip regions were observed. Based on the results of the study and within the limitations of the study, RME with a Hyrax expander results in significant morphological changes of the face after a six-month retention period.
Collapse
|
28
|
Three-dimensional scanners for soft-tissue facial assessment in clinical practice. J Plast Reconstr Aesthet Surg 2021; 74:605-614. [DOI: 10.1016/j.bjps.2020.08.050] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2020] [Accepted: 08/18/2020] [Indexed: 01/01/2023]
|
29
|
Abstract
The reproducibility of scanning in the periorbital region with 3D technology to enable objective evaluations of surgical treatment in the periorbital region was assessed. Facial 3D-scans of 15 volunteers were captured at different time points with a handheld Artec Space Spider structured light scanner. Two scans were made with a one minute interval and repeated after 1 year; for both a natural head position and with the head in a fixation-device. On assessing the area between the eyelashes and eyebrows, the medians of the average deviations between the various cross-sections of the one minute interval 3D-scans ranged from 0.17 to 0.21 mm at baseline, and from 0.10 to 0.11 mm when the minute-interval scanning was repeated one year later. The systematic differences when scanning in a natural head position and fixated position were comparable. The reproducibility of the 3D processing was excellent (intraclass correlation coefficient > 0.9). The repeated scanning deviations (baseline versus one year data) were well within the accepted clinical threshold of 1 mm. Scanning with a hand-held 3D-scanning device (Artec Space Spider) is a promising tool to assess changes in the periorbital region following surgical treatment since the median deviations are well below the clinically accepted 1 mm measuring error, for both the natural head and fixated positions.
Collapse
|
30
|
Nightingale RC, Ross MT, Allenby MC, Woodruff MA, Powell SK. A Method for Economical Smartphone‐Based Clinical 3D Facial Scanning. J Prosthodont 2020; 29:818-825. [DOI: 10.1111/jopr.13274] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/08/2020] [Indexed: 11/29/2022] Open
Affiliation(s)
- Renee Christine Nightingale
- Science and Engineering Faculty Queensland University of Technology (QUT) Brisbane Queensland Australia
- Institute of Health and Biomedical Innovation Queensland University of Technology (QUT) Kelvin Grove Queensland Australia
| | - Maureen Therese Ross
- Science and Engineering Faculty Queensland University of Technology (QUT) Brisbane Queensland Australia
- Institute of Health and Biomedical Innovation Queensland University of Technology (QUT) Kelvin Grove Queensland Australia
| | - Mark Colin Allenby
- Science and Engineering Faculty Queensland University of Technology (QUT) Brisbane Queensland Australia
- Institute of Health and Biomedical Innovation Queensland University of Technology (QUT) Kelvin Grove Queensland Australia
| | - Maria Ann Woodruff
- Science and Engineering Faculty Queensland University of Technology (QUT) Brisbane Queensland Australia
- Institute of Health and Biomedical Innovation Queensland University of Technology (QUT) Kelvin Grove Queensland Australia
| | - Sean Keiran Powell
- Science and Engineering Faculty Queensland University of Technology (QUT) Brisbane Queensland Australia
- Institute of Health and Biomedical Innovation Queensland University of Technology (QUT) Kelvin Grove Queensland Australia
| |
Collapse
|
31
|
Piedra-Cascón W, Meyer MJ, Methani MM, Revilla-León M. Accuracy (trueness and precision) of a dual-structured light facial scanner and interexaminer reliability. J Prosthet Dent 2020; 124:567-574. [DOI: 10.1016/j.prosdent.2019.10.010] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2019] [Revised: 10/08/2019] [Accepted: 10/08/2019] [Indexed: 11/25/2022]
|
32
|
Mai HN, Lee DH. Accuracy of Mobile Device-Compatible 3D Scanners for Facial Digitization: Systematic Review and Meta-Analysis. J Med Internet Res 2020; 22:e22228. [PMID: 33095178 PMCID: PMC7647818 DOI: 10.2196/22228] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2020] [Revised: 09/29/2020] [Accepted: 09/30/2020] [Indexed: 12/11/2022] Open
Abstract
Background The accurate assessment and acquisition of facial anatomical information significantly contributes to enhancing the reliability of treatments in dental and medical fields, and has applications in fields such as craniomaxillofacial surgery, orthodontics, prosthodontics, orthopedics, and forensic medicine. Mobile device–compatible 3D facial scanners have been reported to be an effective tool for clinical use, but the accuracy of digital facial impressions obtained with the scanners has not been explored. Objective We aimed to review comparisons of the accuracy of mobile device–compatible face scanners for facial digitization with that of systems for professional 3D facial scanning. Methods Individual search strategies were employed in PubMed (MEDLINE), Scopus, Science Direct, and Cochrane Library databases to search for articles published up to May 27, 2020. Peer-reviewed journal articles evaluating the accuracy of 3D facial models generated by mobile device–compatible face scanners were included. Cohen d effect size estimates and confidence intervals of standardized mean difference (SMD) data sets were used for meta-analysis. Results By automatic database searching, 3942 articles were identified, of which 11 articles were considered eligible for narrative review, with 6 studies included in the meta-analysis. Overall, the accuracy of face models obtained using mobile device–compatible face scanners was significantly lower than that of face models obtained using professional 3D facial scanners (SMD 3.96 mm, 95% CI 2.81-5.10 mm; z=6.78; P<.001). The difference between face scanning when performed on inanimate facial models was significantly higher (SMD 10.53 mm, 95% CI 6.29-14.77 mm) than that when performed on living participants (SMD 2.58 mm, 95% CI 1.70-3.47 mm, P<.001, df=12.94). Conclusions Overall, mobile device–compatible face scanners did not perform as well as professional scanning systems in 3D facial acquisition, but the deviations were within the clinically acceptable range of <1.5 mm. Significant differences between results when 3D facial scans were performed on inanimate facial objects and when performed on the faces of living participants were found; thus, caution should be exercised when interpreting results from studies conducted on inanimate objects.
Collapse
Affiliation(s)
- Hang-Nga Mai
- Institute for Translational Research in Dentistry, Kyungpook National University, Daegu, Republic of Korea
| | - Du-Hyeong Lee
- Institute for Translational Research in Dentistry, Kyungpook National University, Daegu, Republic of Korea.,Department of Prosthodontics, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea
| |
Collapse
|
33
|
Verna C, Détroit F, Kupczik K, Arnaud J, Balzeau A, Grimaud-Hervé D, Bertrand S, Riou B, Moncel MH. The Middle Pleistocene hominin mandible from Payre (Ardèche, France). J Hum Evol 2020; 144:102775. [DOI: 10.1016/j.jhevol.2020.102775] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2019] [Revised: 02/18/2020] [Accepted: 03/12/2020] [Indexed: 02/06/2023]
|
34
|
Mehta V, Ahmad N. Cone beamed computed tomography in pediatric dentistry: Concepts revisited. J Oral Biol Craniofac Res 2020; 10:210-211. [PMID: 32420015 PMCID: PMC7214934 DOI: 10.1016/j.jobcr.2020.03.013] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2020] [Accepted: 03/31/2020] [Indexed: 01/19/2023] Open
Abstract
Oral diagnosis and treatment planning is of utmost importance in pediatric dentistry. Although intraoral and conventional radiographic procedures have been used extensively since decades, there two-dimensional representation has raised many questions. Cone beamed computed tomography with 3-D technology is a replacement for conventional 2-D imaging and has a wide application among child patients in pediatric dentistry. This article therefore deals with current facts and myths about clinical situations where CBCT is indicated in pediatric patients.
Collapse
Affiliation(s)
- Vivek Mehta
- Department of Pediatric and Preventive Dentistry, Faculty of Dentistry, Jamia Millia Islamia, New Delhi, 110025, India
| | - Nafis Ahmad
- Department of Prosthodontics and Crown and Bridge, Faculty of Dentistry, Jamia Millia Islamia, New Delhi, 110025, India
| |
Collapse
|
35
|
Li M, Fang Z, Cong W, Niu C, Wu W, Uher J, Bennett J, Rubinstein JT, Wang GE. Clinical Micro-CT Empowered by Interior Tomography, Robotic Scanning, and Deep Learning. IEEE ACCESS : PRACTICAL INNOVATIONS, OPEN SOLUTIONS 2020; 8:229018-229032. [PMID: 33777595 PMCID: PMC7996632 DOI: 10.1109/access.2020.3046187] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
While micro-CT systems are instrumental in preclinical research, clinical micro-CT imaging has long been desired with cochlear implantation as a primary application. The structural details of the cochlear implant and the temporal bone require a significantly higher image resolution than that (about 0.2 mm) provided by current medical CT scanners. In this paper, we propose a clinical micro-CT (CMCT) system design integrating conventional spiral cone-beam CT, contemporary interior tomography, deep learning techniques, and the technologies of a micro-focus X-ray source, a photon-counting detector (PCD), and robotic arms for ultrahigh-resolution localized tomography of a freely-selected volume of interest (VOI) at a minimized radiation dose level. The whole system consists of a standard CT scanner for a clinical CT exam and VOI specification, and a robotic micro-CT scanner for a local scan of high spatial and spectral resolution at minimized radiation dose. The prior information from the global scan is also fully utilized for background compensation of the local scan data for accurate and stable VOI reconstruction. Our results and analysis show that the proposed hybrid reconstruction algorithm delivers accurate high-resolution local reconstruction, and is insensitive to the misalignment of the isocenter position, initial view angle and scale mismatch in the data/image registration. These findings demonstrate the feasibility of our system design. We envision that deep learning techniques can be leveraged for optimized imaging performance. With high-resolution imaging, high dose efficiency and low system cost synergistically, our proposed CMCT system has great promise in temporal bone imaging as well as various other clinical applications.
Collapse
Affiliation(s)
- Mengzhou Li
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
| | - Zheng Fang
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
- Department of Instrumental and Electrical Engineering, Xiamen University, Xiamen 361102, China
| | - Wenxiang Cong
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
| | - Chuang Niu
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
| | - Weiwen Wu
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
| | - Josef Uher
- Radalytica a.s., 17000 Prague, Czech Republic
| | | | - Jay T Rubinstein
- Virginia Merrill Bloedel Hearing Research Center, Department of Otolaryngology-HNS, University of Washington, Seattle, WA 98195, USA
| | - G E Wang
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
| |
Collapse
|
36
|
Zhang S, Wu M, Wu Y, Wu G, Liu F. Fixed window aggregation AD-census algorithm for phase-based stereo matching. APPLIED OPTICS 2019; 58:8950-8958. [PMID: 31873677 DOI: 10.1364/ao.58.008950] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2019] [Accepted: 10/14/2019] [Indexed: 06/10/2023]
Abstract
Phase-based stereo matching (PSM) is a vital step in binocular structured light. PSM is hard to strike a balance between efficiency and accuracy, especially because of the absolute phase matrix's (APM) double data type. It means that PSM needs more run time and memory than conventional intensity images' stereo matching. In this paper, we propose a modified absolute difference (AD)-Census algorithm called the fixed window aggregation AD-Census (FWA-AD-Census) to balance the contradiction between efficiency and accuracy in PSM. The FWA-AD-Census aggregates matching cost in a fixed support window instead of an adaptive support window in AD-Census. We analyze the reason why PSM is more suitable to aggregate the matching cost in a fixed support window. Simulations and experiments are conducted to verify the FWA-AD-Census's performances by comparing the FWA-AD-Census with two other local stereo matching algorithms. One is the AD-Census, which is more accurate but less efficient. Its matching cost is aggregated in an adaptive support window. Another is the sum of absolute difference (SAD), which is more efficient but less accurate, and its matching cost is aggregated in a fixed support window. Theoretical analysis and experimental results both indicate that the proposed algorithm can achieve similar accuracy to the AD-Census with less run time.
Collapse
|
37
|
Jain S, Choudhary K, Nagi R, Shukla S, Kaur N, Grover D. New evolution of cone-beam computed tomography in dentistry: Combining digital technologies. Imaging Sci Dent 2019; 49:179-190. [PMID: 31583200 PMCID: PMC6761063 DOI: 10.5624/isd.2019.49.3.179] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2018] [Revised: 04/24/2019] [Accepted: 05/08/2019] [Indexed: 02/06/2023] Open
Abstract
Panoramic radiographs and computed tomography (CT) play a paramount role in the accurate diagnosis, treatment planning, and prognostic evaluation of various complex dental pathologies. The advent of cone-beam computed tomography (CBCT) has revolutionized the practice of dentistry, and this technique is now considered the gold standard for imaging the oral and maxillofacial area due to its numerous advantages, including reductions in exposure time, radiation dose, and cost in comparison to other imaging modalities. This review highlights the broad use of CBCT in the dentomaxillofacial region, and also focuses on future software advancements that can further optimize CBCT imaging.
Collapse
Affiliation(s)
- Supreet Jain
- Department of Oral Medicine and Radiology, New Horizon Dental College and Research Institute, Sakri, Bilaspur, India
| | - Kartik Choudhary
- Department of Pedodontics and Preventive Dentistry, Mansarovar Dental College, Bhopal, India
| | - Ravleen Nagi
- Department of Oral Medicine and Radiology, Swami Devi Dayal Hospital and Dental College, Panchkula, India
| | - Stuti Shukla
- Department of Oral Medicine and Radiology, New Horizon Dental College and Research Institute, Sakri, Bilaspur, India
| | - Navneet Kaur
- Department of Periodontology, National Dental College and Hospital, Dera Bassi, Mohali, India
| | - Deepak Grover
- Department of Periodontology, National Dental College and Hospital, Dera Bassi, Mohali, India
| |
Collapse
|
38
|
Reliability of a three-dimensional facial camera for dental and medical applications: A pilot study. J Prosthet Dent 2019; 122:282-287. [DOI: 10.1016/j.prosdent.2018.10.016] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2017] [Revised: 10/08/2018] [Accepted: 10/08/2018] [Indexed: 11/15/2022]
|
39
|
Kim KA, Chang YJ, Lee SH, An HJ, Park KH. Three-dimensional soft tissue changes according to skeletal changes after mandibular setback surgery by using cone-beam computed tomography and a structured light scanner. Prog Orthod 2019; 20:25. [PMID: 31257550 PMCID: PMC6599813 DOI: 10.1186/s40510-019-0282-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2019] [Accepted: 06/06/2019] [Indexed: 11/24/2022] Open
Abstract
Background To evaluate the three-dimensional (3D) changes after mandibular setback surgery (MSS) in skeletal Class III malocclusion using cone-beam computed tomography (CBCT) and a structured light-based scanner. Methods Twenty-eight adult Korean patients with skeletal Class III malocclusion treated by MSS were evaluated. CBCT and facial scan images were recorded one week before and six months after surgery. To use an identical 3D coordinate system, superimposition was performed, and nine skeletal and 18 soft tissue landmarks were identified. Changes in the landmarks and correlation coefficients and ratios between hard and soft tissue changes were evaluated. Paired t test and Pearson’s correlation test were performed. Results After MSS, the amount of transverse correction was 2.45 mm; mandibular setback, 5.80 mm; and vertical reduction, 1.64 mm at the menton, on average. In the transverse axis, there were significant changes and correlations in the lips and chin and an increasing gradient of ratios from the lower lip to the chin. In the anteroposterior axis, the lower lip and chin moved backward significantly and showed notable correlation with hard tissue movement. In the vertical axis, significant upward movement was observed in the landmarks related to the chin, but only lower facial height was significantly decreased. Conclusions Soft tissue changes according to hard tissue movement after MSS exhibited a distinct pattern of an increasing gradient from the lips to the chin in a transverse aspect.
Collapse
Affiliation(s)
- Kyung-A Kim
- Department of Orthodontics, School of Dentistry, Kyung Hee University, 1 Hoegi-Dong, Dongdaemoon-Ku, Seoul, 130-701, South Korea
| | - Ye-Jin Chang
- Department of Orthodontics, Graduate School, Kyung Hee University, Seoul, South Korea
| | - Su-Hyun Lee
- Department of Orthodontics, Graduate School, Kyung Hee University, Seoul, South Korea
| | - Hyun-Joon An
- Department of Orthodontics, Graduate School, Kyung Hee University, Seoul, South Korea
| | - Ki-Ho Park
- Department of Orthodontics, School of Dentistry, Kyung Hee University, 1 Hoegi-Dong, Dongdaemoon-Ku, Seoul, 130-701, South Korea.
| |
Collapse
|
40
|
Izadi A, Vafaee F, Shishehian A, Roshanaei G, Fathi Afkari B. Evaluation of dimensional accuracy of dental bridges manufactured with conventional casting technique and CAD/CAM system with Ceramill Sintron blocks using CMM. J Dent Res Dent Clin Dent Prospects 2019; 12:264-271. [PMID: 30774792 PMCID: PMC6368946 DOI: 10.15171/joddd.2018.041] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2018] [Accepted: 11/19/2018] [Indexed: 11/09/2022] Open
Abstract
Background. Recently, non-presintered chromium-cobalt (Cr-Co) blocks with the commercial name of Ceramill Sintron were introduced to the market. However, comprehensive studies on the dimensional accuracy and fit of multi-unit frameworks made of these blocks using the coordinate measuring machine (CMM) are lacking. This study aimed to assess and compare the dimensional changes and fit of conventional casting and milled frameworks using Ceramill Sintron.
Methods. A metal model was designed and scanned and 5-unit frameworks were fabricated using two techniques: (I) the conventional casting method (n=20): the wax model was designed, milled in the CAD/CAM machine, flasked and invested; (II) the milling method using Ceramill Sintron blocks (n=20): the wax patterns of group 1 were used; Ceramill Sintron blocks were milled and sintered. Measurements were made on the original reference model and the fabricated frameworks using the CMM in all the three spatial dimensions, and dimensional changes were recorded in a checklist. Data were analyzed with descriptive statistics, and the two groups were compared using one-way ANOVA and Tukey test (α=0.05).
Results. The fabricated frameworks in both groups showed significant dimensional changes in all the three dimensions. Comparison of dimensional changes between the two groups revealed no significant differences (P>0.05) except for transverse changes (arch) that were significantly greater in Ceramill Sintron frameworks (P<0.05).
Conclusion. The two manufacturing processes were the same regarding dimensional changes and the magnitude of marginal gaps and both processes resulted in significant dimensional changes in frameworks. Ceramill Sintron frameworks showed significantly greater transverse changes than the conventional frameworks.
Collapse
Affiliation(s)
- Alireza Izadi
- Department of Prosthodontic Dentistry, Faculty of Dentistry, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Fariborz Vafaee
- Implant Research Center, Department of Prosthodontics, Faculty of Dentistry, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Arash Shishehian
- Department of Prosthodontic Dentistry, Faculty of Dentistry, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Ghodratollah Roshanaei
- Modeling of Noncommunicable Diseases Research Center, Department of Biostatistics and Epidemiology, Faculty of Public Health, Hamadan University
| | - Behzad Fathi Afkari
- Department of Prosthodontic Dentistry, Faculty of Dentistry, Hamadan University of Medical Sciences, Hamadan, Iran
| |
Collapse
|
41
|
Jung J, Lee CH, Lee JW, Choi BJ. Three dimensional evaluation of soft tissue after orthognathic surgery. Head Face Med 2018; 14:21. [PMID: 30290762 PMCID: PMC6173856 DOI: 10.1186/s13005-018-0179-z] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2017] [Accepted: 09/28/2018] [Indexed: 11/28/2022] Open
Abstract
Background To evaluate the nasolabial soft tissue change three-dimensionally after orthognathic surgery, using a structured light scanner. Methods Thirty-two malocclusion patients, who underwent orthognathic surgery, were evaluated. CBCT and 3D facial scans were obtained before surgery and 3 months after surgery. The 3D changes in the 26 landmarks, and the relative ratio of the soft tissue movement to the bony movement, were evaluated. Results In the Le Fort I advancement patients, the nasal tip moved 17% forward, compared to the maxillary bony movement, but the nasal prominence decreased 15%. The alar width increased 4 mm after the advancement, and the width decreased 4.7 mm after Le Fort I setback. The relative ratio of the soft tissue movement to the bony movement after bilateral sagittal split osteotomy was about 66% at the Li point in the anteroposterior direction, and it was 21% in the Le Fort I advancement and 14% in Le Fort I setback at the Ls point. Conclusion Alar cinch suturing may not be sufficient to overcome the effect of the maxilla advancement compressing the nasal complex. Alar width widening was prevented in Le Fort I setback. However, it is uncertain that the alar cinch suturing was solely responsible. The soft tissue around the mandible tends to accompany the bony movement more than the maxillary area. In addition, structured light scanning system proved to be a useful tool to evaluate the nasolabial soft tissue.
Collapse
Affiliation(s)
- Junho Jung
- Department of Oral and Maxillofacial Surgery, School of Dentistry, Kyung Hee University, 26, Kyungheedae-ro, Dongdaemun-gu, 02447, Seoul, Republic of Korea
| | - Chi-Heun Lee
- Department of Oral and Maxillofacial Surgery, School of Dentistry, Kyung Hee University, 26, Kyungheedae-ro, Dongdaemun-gu, 02447, Seoul, Republic of Korea
| | - Jung-Woo Lee
- Department of Oral and Maxillofacial Surgery, School of Dentistry, Kyung Hee University, 26, Kyungheedae-ro, Dongdaemun-gu, 02447, Seoul, Republic of Korea
| | - Byung-Joon Choi
- Department of Oral and Maxillofacial Surgery, School of Dentistry, Kyung Hee University, 26, Kyungheedae-ro, Dongdaemun-gu, 02447, Seoul, Republic of Korea.
| |
Collapse
|
42
|
Influence of involuntary facial expressions on reproducibility of 3D stereophotogrammetry in children with and without complete unilateral cleft lip and palate from 3 to 18 months of age. Clin Oral Investig 2018; 23:1041-1050. [DOI: 10.1007/s00784-018-2520-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2017] [Accepted: 06/06/2018] [Indexed: 11/26/2022]
|
43
|
Hollar KA, Ferguson DS, Everingham JB, Helms JL, Warburton KJ, Lujan TJ. Quantifying wear depth in hip prostheses using a 3D optical scanner. WEAR : AN INTERNATIONAL JOURNAL ON THE SCIENCE AND TECHNOLOGY OF FRICTION LUBRICATION AND WEAR 2018; 394-395:195-202. [PMID: 30220743 PMCID: PMC6136671 DOI: 10.1016/j.wear.2017.10.008] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
The visualization of wear depth in hip prostheses can assist the evaluation of new bearing materials and implant designs. The goal of this study was to develop an accurate, fast, and economical methodology to generate colorimetric maps of wear depth in hip implants using a structured light 3D optical scanning system. The accuracy and precision of this novel technique were determined using reference blocks with known wear depths. This technique was then used to measure the in vitro wear of a hip resurfacing device for canines that incorporates a highly cross-linked polyethylene liner. The 3D optical scanner had an average accuracy of 2.1 µm and an average precision of 1.4 µm, which corresponded to errors less than 10% when measuring wear depths of 20 µm or greater. The scanner was able to repeatedly generate 3D colorimetric maps of wear depth in highly cross-linked polyethylene liners in 20 min or less. These colorimetric maps identified localized regions with 3-fold greater wear than the average wear depth, and revealed liners with asymmetric wear patterns. For the first time, this study has validated the use of 3D optical scanning to quantify in vitro surface wear in a hip replacement device.
Collapse
Affiliation(s)
- Katherine A. Hollar
- Boise State University, 1910 University Drive, Boise, ID 83725-2085, United States
| | - Daniel S. Ferguson
- Global Inspection Solutions, LLC, 6635 North Baltimore Avenue, Portland, OR 97203, United States
| | - John B. Everingham
- Boise State University, 1910 University Drive, Boise, ID 83725-2085, United States
| | - Jillian L. Helms
- Boise State University, 1910 University Drive, Boise, ID 83725-2085, United States
| | - Kevin J. Warburton
- Boise State University, 1910 University Drive, Boise, ID 83725-2085, United States
| | - Trevor J. Lujan
- Boise State University, 1910 University Drive, Boise, ID 83725-2085, United States
| |
Collapse
|
44
|
Lee KW, Kim SH, Gil YC, Hu KS, Kim HJ. Validity and reliability of a structured-light 3D scanner and an ultrasound imaging system for measurements of facial skin thickness. Clin Anat 2017; 30:878-886. [DOI: 10.1002/ca.22931] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2017] [Accepted: 05/29/2017] [Indexed: 10/19/2022]
Affiliation(s)
- Kang-Woo Lee
- Division in Anatomy and Developmental Biology, Department of Oral Biology; Human Identification Research Center, BK21 PLUS Project, Yonsei University College of Dentistry; Seoul 03722 South Korea
| | - Sang-Hwan Kim
- Division in Anatomy and Developmental Biology, Department of Oral Biology; Human Identification Research Center, BK21 PLUS Project, Yonsei University College of Dentistry; Seoul 03722 South Korea
| | - Young-Chun Gil
- Division in Anatomy and Developmental Biology, Department of Oral Biology; Human Identification Research Center, BK21 PLUS Project, Yonsei University College of Dentistry; Seoul 03722 South Korea
| | - Kyung-Seok Hu
- Division in Anatomy and Developmental Biology, Department of Oral Biology; Human Identification Research Center, BK21 PLUS Project, Yonsei University College of Dentistry; Seoul 03722 South Korea
| | - Hee-Jin Kim
- Division in Anatomy and Developmental Biology, Department of Oral Biology; Human Identification Research Center, BK21 PLUS Project, Yonsei University College of Dentistry; Seoul 03722 South Korea
| |
Collapse
|
45
|
Simunovic F, Schlager S, Montanari M, Iblher N. Prospective 3D analysis of facial soft tissue augmentation with calcium hydroxylapatite. J COSMET LASER THER 2017; 19:283-289. [DOI: 10.1080/14764172.2017.1307411] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Affiliation(s)
- Filip Simunovic
- Department of Plastic and Hand Surgery, Freiburg University Medical Center, Freiburg, Germany
| | - Stefan Schlager
- Department of Biological Anthropology, University of Freiburg, Freiburg, Germany
| | | | - Niklas Iblher
- Private Practice for Plastic and Aesthetic Surgery, Freiburg, Germany
| |
Collapse
|
46
|
Abstract
STUDY DESIGN Serial histological investigation was performed on 10 cadaveric specimens and biomechanical tests were performed on five specimens, both focused on the tissue connexion between the rectus capitis posterior minor (RCPMi) and the spinal dura. OBJECTIVE This study had two components: to clarify the microscopic structure of the tissue link between RCPMi and the dura mater, and to evaluate the mechanical role of this tissue complex. SUMMARY OF BACKGROUND DATA Dissection-based and imaging-based reports have suggested a connective tissue link between the RCPMi and the dura mater at the posterior-atlanto-occipital (PAO) level. Existence of this link, and properties, remain unclear. METHODS Histological investigation: RCPMi muscles, their bony attachments, PAO space, and adjacent spinal dura mater were resected from 10 cadavers. Tissues were subdivided into medial and lateral parts. Serial histological sections were prepared to cover maximum surface area; Masson trichrome stain was used to evaluate the tissue connection. Biomechanical investigation: individualized RCPMi muscles from five cadavers were detached from their origin. Each muscle was loaded incrementally up to 2 kg, with the cervical spine hyperextended. Using a structured light scanner, the dura mater was scanned for each loaded state. Comparison between unloaded and each loaded scanned surface quantified the displacement of the dura mater. RESULTS Histological investigation confirmed the existence of a connective tissue link between the RCPMi and the dura mater. The biomechanical testing suggests that this tissue link complex can reduce the bulging of the dura mater into the spinal canal, caused during hyperextension, by 53.4% ± 6.9% under RCPMi loading. CONCLUSION This histological investigation clarified the structure of the tissue link between the RCPMi and the dura mater. The biomechanical testing indicated a potential mechanical function of the RCPMi in regards to the spinal dura mater, which may include a stabilizing role of the dura mater during neck extension. LEVEL OF EVIDENCE N/A.
Collapse
|
47
|
Dindaroğlu F, Duran GS, Görgülü S. Reproducibility of the lip position at rest: A 3-dimensional perspective. Am J Orthod Dentofacial Orthop 2017; 149:757-65. [PMID: 27131258 DOI: 10.1016/j.ajodo.2015.10.029] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2014] [Revised: 10/01/2015] [Accepted: 10/01/2015] [Indexed: 10/21/2022]
Abstract
INTRODUCTION In this study, we evaluated the reproducibility of the lip position at rest in 3 dimensions using reverse engineering software and stereophotogrammetric images. METHODS We used 3dMD Flex (3dMD, Atlanta, Ga) to obtain 60 stereophotogrammetric images from the same participant. Thirty images were obtained in 3 sessions on the same day, and the procedure was repeated 6 weeks later for 30 more images. The surface-base registration, the segmentation of the upper and lower lips, and the 3-dimensional deviation analysis were performed with Geomagic Control (3D Systems, Rock Hill, SC) software. The Shapiro-Wilk test, paired sample t test, Bland-Altman plots, and Wilcoxon signed rank test were used for statistical analysis at a significance level of P <0.05. RESULTS The deviations of the upper lip on the first images were between 0.16 and 1.39 mm. The mean total deviation was 0.25 ± 0.12 mm. The mean deviation of the lower lip was 0.34 ± 0.17 mm. The deviations were observed between -1.96 and 1.97 mm. When the mean positive (P = 0.633 and P = 0.171, respectively) and the mean negative (P = 0.771 and P = 0.842, respectively) deviations of the upper and lower lips were analyzed, there was no significant difference between the 2 time points. CONCLUSIONS The results suggest that the rest position can be reproduced within a small range both on the same day and between the sessions. More research with larger samples is needed to confirm these results.
Collapse
Affiliation(s)
- Furkan Dindaroğlu
- Research assistant, Department of Orthodontics, Dental Sciences Center, Gülhane Military Medical Academy, Etlik, Ankara, Turkey.
| | - Gökhan Serhat Duran
- Postgraduate student, Department of Orthodontics, Dental Sciences Center, Gülhane Military Medical Academy, Etlik, Ankara, Turkey
| | - Serkan Görgülü
- Associate professor, Department of Orthodontics, Dental Sciences Center, Gülhane Military Medical Academy, Etlik, Ankara, Turkey
| |
Collapse
|
48
|
Three-Dimensional Handheld Scanning to Quantify Head-Shape Changes in Spring-Assisted Surgery for Sagittal Craniosynostosis. J Craniofac Surg 2016; 27:2117-2123. [DOI: 10.1097/scs.0000000000003108] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
49
|
Analysis and Compensation for Lateral Chromatic Aberration in a Color Coding Structured Light 3D Measurement System. SENSORS 2016; 16:s16091426. [PMID: 27598174 PMCID: PMC5038704 DOI: 10.3390/s16091426] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/13/2016] [Revised: 08/13/2016] [Accepted: 08/30/2016] [Indexed: 11/20/2022]
Abstract
While color-coding methods have improved the measuring efficiency of a structured light three-dimensional (3D) measurement system, they decreased the measuring accuracy significantly due to lateral chromatic aberration (LCA). In this study, the LCA in a structured light measurement system is analyzed, and a method is proposed to compensate the error caused by the LCA. Firstly, based on the projective transformation, a 3D error map of LCA is constructed in the projector images by using a flat board and comparing the image coordinates of red, green and blue circles with the coordinates of white circles at preselected sample points within the measurement volume. The 3D map consists of the errors, which are the equivalent errors caused by LCA of the camera and projector. Then in measurements, error values of LCA are calculated and compensated to correct the projector image coordinates through the 3D error map and a tri-linear interpolation method. Eventually, 3D coordinates with higher accuracy are re-calculated according to the compensated image coordinates. The effectiveness of the proposed method is verified in the following experiments.
Collapse
|
50
|
Brüllmann D, Muench T, Schulze R. Construction of a low-cost surface scanner for medical studies: a feasibility study. Oral Radiol 2016. [DOI: 10.1007/s11282-016-0236-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|