1
|
Yang X, Liu L, Yan Z, Yu J, Hu X, Yu X, Dong C, Chen J, Liu H, Yu Z, Deng X, Ni D, Gou Z, Huang X. Hierarchical online contrastive anomaly detection for fetal arrhythmia diagnosis in ultrasound. Med Image Anal 2024; 97:103229. [PMID: 38897033 DOI: 10.1016/j.media.2024.103229] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Revised: 03/10/2024] [Accepted: 06/03/2024] [Indexed: 06/21/2024]
Abstract
Arrhythmia is a major cardiac abnormality in fetuses. Therefore, early diagnosis of arrhythmia is clinically crucial. Pulsed-wave Doppler ultrasound is a commonly used diagnostic tool for fetal arrhythmia. Its key step for diagnosis involves identifying adjacent measurable cardiac cycles (MCCs). As cardiac activity is complex and the experience of sonographers is often varied, automation can improve user-independence and diagnostic-validity. However, arrhythmias pose several challenges for automation because of complex waveform variations, which can cause major localization bias and missed or false detection of MCCs. Filtering out non-MCC anomalies is difficult because of large intra-class and small inter-class variations between MCCs and non-MCCs caused by agnostic morphological waveform variations. Moreover, rare arrhythmia cases are insufficient for classification algorithms to adequately learn discriminative features. Using only normal cases for training, we propose a novel hierarchical online contrastive anomaly detection (HOCAD) framework for arrhythmia diagnosis during test time. The contribution of this study is three-fold. First, we develop a coarse-to-fine framework inspired by hierarchical diagnostic logic, which can refine localization and avoid missed detection of MCCs. Second, we propose an online learning-based contrastive anomaly detection with two new anomaly scores, which can adaptively filter out non-MCC anomalies on a single image during testing. With these complementary efforts, we precisely determine MCCs for correct measurements and diagnosis. Third, to the best of our knowledge, this is the first reported study investigating intelligent diagnosis of fetal arrhythmia on a large-scale and multi-center ultrasound dataset. Extensive experiments on 3850 cases, including 266 cases covering three typical types of arrhythmias, demonstrate the effectiveness of the proposed framework.
Collapse
Affiliation(s)
- Xin Yang
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, China, Shenzhen, China; Medical Ultrasound Image Computing (MUSIC) Laboratory, Shenzhen University, Shenzhen, China
| | - Lian Liu
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, China, Shenzhen, China; Medical Ultrasound Image Computing (MUSIC) Laboratory, Shenzhen University, Shenzhen, China
| | - Zhongnuo Yan
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, China, Shenzhen, China; Medical Ultrasound Image Computing (MUSIC) Laboratory, Shenzhen University, Shenzhen, China
| | - Junxuan Yu
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, China, Shenzhen, China; Medical Ultrasound Image Computing (MUSIC) Laboratory, Shenzhen University, Shenzhen, China
| | - Xindi Hu
- Shenzhen RayShape Medical Technology Co., Ltd, Shenzhen, Guangdong, China
| | - Xuejuan Yu
- Department of Ultrasonography, Suzhou Xiangcheng People's Hospital, Suzhou, Jiangsu, China
| | - Caixia Dong
- Department of Ultrasonography, Wulin Hospital, Hangzhou, Zhejiang, China
| | - Ju Chen
- Department of Ultrasonography, Taicang First People's Hospital, Suzhou, Jiangsu, China
| | - Hongmei Liu
- Department of Ultrasonography, Panzhou Emerging Hospital, Panzhou, Guizhou, China
| | - Zhuan Yu
- Department of Ultrasonography, The Affiliated Hospital of Jiangsu University, Zhenjiang, Jiangsu, China
| | - Xuedong Deng
- Center for Medical Ultrasound, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, Jiangsu, China
| | - Dong Ni
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, China, Shenzhen, China; Medical Ultrasound Image Computing (MUSIC) Laboratory, Shenzhen University, Shenzhen, China
| | - Zhongshan Gou
- Center for Cardiovascular Disease, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, Jiangsu, China.
| | - Xiaoqiong Huang
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, China, Shenzhen, China; Medical Ultrasound Image Computing (MUSIC) Laboratory, Shenzhen University, Shenzhen, China.
| |
Collapse
|
2
|
Giordano N, Sbrollini A, Morettini M, Rosati S, Balestra G, Gambi E, Knaflitz M, Burattini L. Acquisition Devices for Fetal Phonocardiography: A Scoping Review. Bioengineering (Basel) 2024; 11:367. [PMID: 38671788 PMCID: PMC11048557 DOI: 10.3390/bioengineering11040367] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Revised: 03/29/2024] [Accepted: 04/09/2024] [Indexed: 04/28/2024] Open
Abstract
Timely and reliable fetal monitoring is crucial to prevent adverse events during pregnancy and delivery. Fetal phonocardiography, i.e., the recording of fetal heart sounds, is emerging as a novel possibility to monitor fetal health status. Indeed, due to its passive nature and its noninvasiveness, the technique is suitable for long-term monitoring and for telemonitoring applications. Despite the high share of literature focusing on signal processing, no previous work has reviewed the technological hardware solutions devoted to the recording of fetal heart sounds. Thus, the aim of this scoping review is to collect information regarding the acquisition devices for fetal phonocardiography (FPCG), focusing on technical specifications and clinical use. Overall, PRISMA-guidelines-based analysis selected 57 studies that described 26 research prototypes and eight commercial devices for FPCG acquisition. Results of our review study reveal that no commercial devices were designed for fetal-specific purposes, that the latest advances involve the use of multiple microphones and sensors, and that no quantitative validation was usually performed. By highlighting the past and future trends and the most relevant innovations from both a technical and clinical perspective, this review will represent a useful reference for the evaluation of different acquisition devices and for the development of new FPCG-based systems for fetal monitoring.
Collapse
Affiliation(s)
- Noemi Giordano
- Department of Electronics and Telecommunications and PoliToBIOMedLab, Politecnico di Torino, 10129 Torino, Italy; (N.G.); (S.R.); (G.B.); (M.K.)
| | - Agnese Sbrollini
- Department of Information Engineering, Engineering Faculty, Università Politecnica delle Marche, 60131 Ancona, Italy; (A.S.); (M.M.); (E.G.)
| | - Micaela Morettini
- Department of Information Engineering, Engineering Faculty, Università Politecnica delle Marche, 60131 Ancona, Italy; (A.S.); (M.M.); (E.G.)
| | - Samanta Rosati
- Department of Electronics and Telecommunications and PoliToBIOMedLab, Politecnico di Torino, 10129 Torino, Italy; (N.G.); (S.R.); (G.B.); (M.K.)
| | - Gabriella Balestra
- Department of Electronics and Telecommunications and PoliToBIOMedLab, Politecnico di Torino, 10129 Torino, Italy; (N.G.); (S.R.); (G.B.); (M.K.)
| | - Ennio Gambi
- Department of Information Engineering, Engineering Faculty, Università Politecnica delle Marche, 60131 Ancona, Italy; (A.S.); (M.M.); (E.G.)
| | - Marco Knaflitz
- Department of Electronics and Telecommunications and PoliToBIOMedLab, Politecnico di Torino, 10129 Torino, Italy; (N.G.); (S.R.); (G.B.); (M.K.)
| | - Laura Burattini
- Department of Information Engineering, Engineering Faculty, Università Politecnica delle Marche, 60131 Ancona, Italy; (A.S.); (M.M.); (E.G.)
| |
Collapse
|
3
|
Stremmel C, Breitschwerdt R. Digital Transformation in the Diagnostics and Therapy of Cardiovascular Diseases: Comprehensive Literature Review. JMIR Cardio 2023; 7:e44983. [PMID: 37647103 PMCID: PMC10500361 DOI: 10.2196/44983] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2022] [Revised: 06/12/2023] [Accepted: 08/07/2023] [Indexed: 09/01/2023] Open
Abstract
BACKGROUND The digital transformation of our health care system has experienced a clear shift in the last few years due to political, medical, and technical innovations and reorganization. In particular, the cardiovascular field has undergone a significant change, with new broad perspectives in terms of optimized treatment strategies for patients nowadays. OBJECTIVE After a short historical introduction, this comprehensive literature review aimed to provide a detailed overview of the scientific evidence regarding digitalization in the diagnostics and therapy of cardiovascular diseases (CVDs). METHODS We performed an extensive literature search of the PubMed database and included all related articles that were published as of March 2022. Of the 3021 studies identified, 1639 (54.25%) studies were selected for a structured analysis and presentation (original articles: n=1273, 77.67%; reviews or comments: n=366, 22.33%). In addition to studies on CVDs in general, 829 studies could be assigned to a specific CVD with a diagnostic and therapeutic approach. For data presentation, all 829 publications were grouped into 6 categories of CVDs. RESULTS Evidence-based innovations in the cardiovascular field cover a wide medical spectrum, starting from the diagnosis of congenital heart diseases or arrhythmias and overoptimized workflows in the emergency care setting of acute myocardial infarction to telemedical care for patients having chronic diseases such as heart failure, coronary artery disease, or hypertension. The use of smartphones and wearables as well as the integration of artificial intelligence provides important tools for location-independent medical care and the prevention of adverse events. CONCLUSIONS Digital transformation has opened up multiple new perspectives in the cardiovascular field, with rapidly expanding scientific evidence. Beyond important improvements in terms of patient care, these innovations are also capable of reducing costs for our health care system. In the next few years, digital transformation will continue to revolutionize the field of cardiovascular medicine and broaden our medical and scientific horizons.
Collapse
|
4
|
Cheema A, Singh M, Kumar M, Setia G. Combined empirical mode decomposition and phase space reconstruction based psychologically stressed and non-stressed state classification from cardiac sound signals. Biomed Signal Process Control 2023. [DOI: 10.1016/j.bspc.2023.104585] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
|
5
|
Jiménez-González A, Salas-Márquez U. Time-frequency characteristics of the vibrations underlying the first fetal heart sound: a preliminary study. Med Biol Eng Comput 2023; 61:739-756. [PMID: 36598675 DOI: 10.1007/s11517-022-02756-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2021] [Accepted: 12/22/2022] [Indexed: 01/05/2023]
Abstract
This work studied, for the first time, the time-frequency characteristics of the vibrations underlying the first fetal heart sound (S1). To this end, the continuous wavelet transform was used to produce time-energy and time-frequency representations of S1 from where five vibrations were studied by their timing, energy, and frequency characteristics in three gestational age groups (early, G1, preterm, G2, and term, G3). Results on a dataset of 1111 S1s (9 phonocardiograms between 33 and 40 weeks) indicate that such representations uncovered a set of five well-defined, non-overlapped, and large-energy vibrations whose features presented interesting behaviors. Thus, for each group, while the timing characteristics of the five vibrations were likely to be statically different, their frequencies were similar. Also, the energies of the vibrations were likely to be different only in G2 and G3. Alternatively, while the frequencies and energies of each vibration were likely to statistically change among groups (excluding the energy of the third vibration), the timings were more likely to change only from G1 to G2 and from G2 to G3. Therefore, this methodology seems suitable to detect and study the generating vibrations of S1. Future work will test the correlation between these vibrations and the valvular events.
Collapse
Affiliation(s)
- Aída Jiménez-González
- Department of Electrical Engineering, Universidad Autónoma Metropolitana-Iztapalapa, Av. San Rafael Atlixco 186, Col. Vicentina, Alcaldía Iztapalapa, C.P. 09340, México City, México.
| | - Usiel Salas-Márquez
- Department of Electrical Engineering, Universidad Autónoma Metropolitana-Iztapalapa, Av. San Rafael Atlixco 186, Col. Vicentina, Alcaldía Iztapalapa, C.P. 09340, México City, México
| |
Collapse
|
6
|
Kahankova R, Barnova K, Jaros R, Pavlicek J, Snasel V, Martinek R. Pregnancy in the time of COVID-19: towards Fetal monitoring 4.0. BMC Pregnancy Childbirth 2023; 23:33. [PMID: 36647041 PMCID: PMC9841500 DOI: 10.1186/s12884-023-05349-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Accepted: 01/05/2023] [Indexed: 01/18/2023] Open
Abstract
On the outbreak of the global COVID-19 pandemic, high-risk and vulnerable groups in the population were at particular risk of severe disease progression. Pregnant women were one of these groups. The infectious disease endangered not only the physical health of pregnant women, but also their mental well-being. Improving the mental health of pregnant women and reducing their risk of an infectious disease could be achieved by using remote home monitoring solutions. These would allow the health of the mother and fetus to be monitored from the comfort of their home, a reduction in the number of physical visits to the doctor and thereby eliminate the need for the mother to venture into high-risk public places. The most commonly used technique in clinical practice, cardiotocography, suffers from low specificity and requires skilled personnel for the examination. For that and due to the intermittent and active nature of its measurements, it is inappropriate for continuous home monitoring. The pandemic has demonstrated that the future lies in accurate remote monitoring and it is therefore vital to search for an option for fetal monitoring based on state-of-the-art technology that would provide a safe, accurate, and reliable information regarding fetal and maternal health state. In this paper, we thus provide a technical and critical review of the latest literature and on this topic to provide the readers the insights to the applications and future directions in fetal monitoring. We extensively discuss the remaining challenges and obstacles in future research and in developing the fetal monitoring in the new era of Fetal monitoring 4.0, based on the pillars of Healthcare 4.0.
Collapse
Affiliation(s)
- Radana Kahankova
- grid.440850.d0000 0000 9643 2828Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB–Technical University of Ostrava, Ostrava, Czechia
| | - Katerina Barnova
- grid.440850.d0000 0000 9643 2828Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB–Technical University of Ostrava, Ostrava, Czechia
| | - Rene Jaros
- grid.440850.d0000 0000 9643 2828Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB–Technical University of Ostrava, Ostrava, Czechia
| | - Jan Pavlicek
- grid.412684.d0000 0001 2155 4545Department of Pediatrics, Faculty Hospital, Faculty of Medicine, Ostrava University, Ostrava, Czechia
| | - Vaclav Snasel
- grid.440850.d0000 0000 9643 2828Department of Computer Science, Faculty of Electrical Engineering and Computer Science, VSB–Technical University of Ostrava, Ostrava, Czechia
| | - Radek Martinek
- grid.440850.d0000 0000 9643 2828Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB–Technical University of Ostrava, Ostrava, Czechia
| |
Collapse
|
7
|
Farahi M, Casals A, Sarrafzadeh O, Zamani Y, Ahmadi H, Behbood N, Habibian H. Beat-to-beat fetal heart rate analysis using portable medical device and wavelet transformation technique. Heliyon 2022; 8:e12655. [PMID: 36636218 PMCID: PMC9830175 DOI: 10.1016/j.heliyon.2022.e12655] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Revised: 06/26/2022] [Accepted: 12/18/2022] [Indexed: 12/24/2022] Open
Abstract
Objective: Beat-to-beat tele-fetal monitoring and comparison with clinical data are studied with a wavelet transformation approach. Tele-fetal monitoring is a big progress toward a wearable medical device for pregnant women capable of obtaining prenatal care at home. Study Design: We apply a wavelet transformation algorithm for fetal cardiac monitoring using a portable fetal Doppler medical device. After an investigation of 85 different mother wavelets, a bio-orthogonal 2.2 mother wavelet in level 4 of decomposition is chosen. The efficiency of the proposed method is evaluated using two data sets including public and clinical. Results: From publicly available data on PhysioBank, and simultaneous clinical measurement, we prove that the comparison between obtained fetal heart rate by the algorithm and the baselines yields a promising accuracy beyond 95%. Conclusion: Finally, we conclude that the proposed algorithm would be a robust technique for any similar tele-fetal monitoring approach.
Collapse
Affiliation(s)
- Maria Farahi
- Sana Meditech S.L. Company, 08014 Barcelona, Spain,Enginyeria de Sistemas, Automatica i Informatica Industrial (ESAII), Universitat Politècnica de Catalunya, 08034 Barcelona, Spain,Corresponding author at: Enginyeria de Sistemas, Automatica i Informatica Industrial (ESAII), Universitat Politècnica de Catalunya, 08034 Barcelona, Spain.
| | - Alícia Casals
- Enginyeria de Sistemas, Automatica i Informatica Industrial (ESAII), Universitat Politècnica de Catalunya, 08034 Barcelona, Spain
| | | | | | | | | | | |
Collapse
|
8
|
Mallegni N, Molinari G, Ricci C, Lazzeri A, La Rosa D, Crivello A, Milazzo M. Sensing Devices for Detecting and Processing Acoustic Signals in Healthcare. BIOSENSORS 2022; 12:835. [PMID: 36290973 PMCID: PMC9599683 DOI: 10.3390/bios12100835] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 09/27/2022] [Accepted: 10/05/2022] [Indexed: 06/16/2023]
Abstract
Acoustic signals are important markers to monitor physiological and pathological conditions, e.g., heart and respiratory sounds. The employment of traditional devices, such as stethoscopes, has been progressively superseded by new miniaturized devices, usually identified as microelectromechanical systems (MEMS). These tools are able to better detect the vibrational content of acoustic signals in order to provide a more reliable description of their features (e.g., amplitude, frequency bandwidth). Starting from the description of the structure and working principles of MEMS, we provide a review of their emerging applications in the healthcare field, discussing the advantages and limitations of each framework. Finally, we deliver a discussion on the lessons learned from the literature, and the open questions and challenges in the field that the scientific community must address in the near future.
Collapse
Affiliation(s)
- Norma Mallegni
- Department of Civil and Industrial Engineering, University of Pisa, 56122 Pisa, Italy
| | - Giovanna Molinari
- Department of Civil and Industrial Engineering, University of Pisa, 56122 Pisa, Italy
| | - Claudio Ricci
- Department of Civil and Industrial Engineering, University of Pisa, 56122 Pisa, Italy
| | - Andrea Lazzeri
- Department of Civil and Industrial Engineering, University of Pisa, 56122 Pisa, Italy
| | - Davide La Rosa
- ISTI-CNR, Institute of Information Science and Technologies, 56124 Pisa, Italy
| | - Antonino Crivello
- ISTI-CNR, Institute of Information Science and Technologies, 56124 Pisa, Italy
| | - Mario Milazzo
- Department of Civil and Industrial Engineering, University of Pisa, 56122 Pisa, Italy
| |
Collapse
|
9
|
Non-invasive fetal monitoring: Fetal Heart Rate multimodal estimation from abdominal electrocardiography and phonocardiography. J Gynecol Obstet Hum Reprod 2022; 51:102421. [DOI: 10.1016/j.jogoh.2022.102421] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Revised: 05/26/2022] [Accepted: 06/02/2022] [Indexed: 11/19/2022]
|
10
|
Barnova K, Kahankova R, Jaros R, Litschmannova M, Martinek R. A comparative study of single-channel signal processing methods in fetal phonocardiography. PLoS One 2022; 17:e0269884. [PMID: 35984866 PMCID: PMC9390939 DOI: 10.1371/journal.pone.0269884] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2021] [Accepted: 05/29/2022] [Indexed: 11/18/2022] Open
Abstract
Fetal phonocardiography is a non-invasive, completely passive and low-cost method based on sensing acoustic signals from the maternal abdomen. However, different types of interference are sensed along with the desired fetal phonocardiography. This study focuses on the comparison of fetal phonocardiography filtering using eight algorithms: Savitzky-Golay filter, finite impulse response filter, adaptive wavelet transform, maximal overlap discrete wavelet transform, variational mode decomposition, empirical mode decomposition, ensemble empirical mode decomposition, and complete ensemble empirical mode decomposition with adaptive noise. The effectiveness of those methods was tested on four types of interference (maternal sounds, movement artifacts, Gaussian noise, and ambient noise) and eleven combinations of these disturbances. The dataset was created using two synthetic records r01 and r02, where the record r02 was loaded with higher levels of interference than the record r01. The evaluation was performed using the objective parameters such as accuracy of the detection of S1 and S2 sounds, signal-to-noise ratio improvement, and mean error of heart interval measurement. According to all parameters, the best results were achieved using the complete ensemble empirical mode decomposition with adaptive noise method with average values of accuracy = 91.53% in the detection of S1 and accuracy = 68.89% in the detection of S2. The average value of signal-to-noise ratio improvement achieved by complete ensemble empirical mode decomposition with adaptive noise method was 9.75 dB and the average value of the mean error of heart interval measurement was 3.27 ms.
Collapse
Affiliation(s)
- Katerina Barnova
- Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB–Technical University of Ostrava, Ostrava, Czechia
| | - Radana Kahankova
- Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB–Technical University of Ostrava, Ostrava, Czechia
| | - Rene Jaros
- Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB–Technical University of Ostrava, Ostrava, Czechia
- * E-mail:
| | - Martina Litschmannova
- Department of Applied Mathematics, Faculty of Electrical Engineering and Computer Science, VSB–Technical University of Ostrava, Ostrava, Czechia
| | - Radek Martinek
- Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB–Technical University of Ostrava, Ostrava, Czechia
| |
Collapse
|
11
|
Al-yousif S, Najm IA, Talab HS, Hasan Al Qahtani N, Alfiras M, Al-Rawi OYM, Subhi Al-Dayyeni W, Amer Ahmed Alrawi A, Jabbar Mnati M, Jarrar M, Ghabban F, Al-Shareefi NA, Musa Jaber M, H. Saleh A, Md Tahir N, Najim HT, Taher M. Intrapartum cardiotocography trace pattern pre-processing, features extraction and fetal health condition diagnoses based on RCOG guideline. PeerJ Comput Sci 2022; 8:e1050. [PMID: 36092005 PMCID: PMC9454876 DOI: 10.7717/peerj-cs.1050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2021] [Accepted: 06/30/2022] [Indexed: 06/15/2023]
Abstract
CONTEXT The computerization of both fetal heart rate (FHR) and intelligent classification modeling of the cardiotocograph (CTG) is one of the approaches that are utilized in assisting obstetricians in conducting initial interpretation based on (CTG) analysis. CTG tracing interpretation is crucial for the monitoring of the fetal status during weeks into the pregnancy and childbirth. Most contemporary studies rely on computer-assisted fetal heart rate (FHR) feature extraction and CTG categorization to determine the best precise diagnosis for tracking fetal health during pregnancy. Furthermore, through the utilization of a computer-assisted fetal monitoring system, the FHR patterns can be precisely detected and categorized. OBJECTIVE The goal of this project is to create a reliable feature extraction algorithm for the FHR as well as a systematic and viable classifier for the CTG through the utilization of the MATLAB platform, all the while adhering to the recognized Royal College of Obstetricians and Gynecologists (RCOG) recommendations. METHOD The compiled CTG data from spiky artifacts were cleaned by a specifically created application and compensated for missing data using the guidelines provided by RCOG and the MATLAB toolbox after the implemented data has been processed and the FHR fundamental features have been extracted, for example, the baseline, acceleration, deceleration, and baseline variability. This is followed by the classification phase based on the MATLAB environment. Next, using the guideline provided by the RCOG, the signals patterns of CTG were classified into three categories specifically as normal, abnormal (suspicious), or pathological. Furthermore, to ensure the effectiveness of the created computerized procedure and confirm the robustness of the method, the visual interpretation performed by five obstetricians is compared with the results utilizing the computerized version for the 150 CTG signals. RESULTS The attained CTG signal categorization results revealed that there is variability, particularly a trivial dissimilarity of approximately (+/-4 and 6) beats per minute (b.p.m.). It was demonstrated that obstetricians' observations coincide with algorithms based on deceleration type and number, except for acceleration values that differ by up to (+/-4). DISCUSSION The results obtained based on CTG interpretation showed that the utilization of the computerized approach employed in infirmaries and home care services for pregnant women is indeed suitable. CONCLUSIONS The classification based on CTG that was used for the interpretation of the FHR attribute as discussed in this study is based on the RCOG guidelines. The system is evaluated and validated by experts based on their expert opinions and was compared with the CTG feature extraction and classification algorithms developed using MATLAB.
Collapse
Affiliation(s)
- Shahad Al-yousif
- Research Centre, The University of Almashreq, Baghdad, Iraq
- College of Engineering, Department of Electrical & Electronic Engineering, Gulf University, Almasnad, Kingdom of Bahrain
- Department of Medical Instrumentation Engineering Techniques, Dijlah University College, Baghdad, Iraq
| | - Ihab A. Najm
- College of Engineering, Tikrit University, Tikrit, Iraq
| | - Hossam Subhi Talab
- Children Welfare Teaching Hospital, Medical City, (MD, CABP, CAB Neonatology), Baghdad, Iraq
| | - Nourah Hasan Al Qahtani
- Department of Obstetrics and Gynecology, College of Medicine, Imam Abdulrahman Bin Faisal University, Al Dammam, Saudi Arabia
| | - M. Alfiras
- College of Engineering, Department of Electrical & Electronic Engineering, Gulf University, Almasnad, Kingdom of Bahrain
| | - Osama YM Al-Rawi
- College of Engineering, Department of Electrical & Electronic Engineering, Gulf University, Almasnad, Kingdom of Bahrain
| | | | | | - Mohannad Jabbar Mnati
- Department of Electronic Technology, Institute of Technology Baghdad, Middle Technical University, Baghdad, Iraq
| | - Mu’taman Jarrar
- College of Medicine, Imam Abdulrahman Bin Faisal University, Al Dammam, Saudi Arabia
| | - Fahad Ghabban
- Department of Information Systems College of Computer Science and Engineering, Taibah University, Al Madinah Al Munawwarah, Saudi Arabia
| | - Nael A. Al-Shareefi
- College of Biomedical Informatics, University of Information Technology and Communications (UOITC), Baghdad, Iraq
| | - Mustafa Musa Jaber
- Al-Turath University College, Department of Computer Engineering, Baghdad, Iraq
- Department of Medical Instruments Engineering Techniques, Al-Farahidi University, Baghdad, Iraq
| | | | - Nooritawati Md Tahir
- Electrical Engineering Department, College of Engineering, Universiti Teknologi MARA, Shah Alam, Malaysia
- Integrative Pharmacogenomics Institute (iPROMISE), Universiti Teknologi MARA, Shah Alam, Malaysia
- Institute of Big Data Analytics and Artificial Intelligence (IBDAAI), Universiti Teknologi MARA, Shah Alam, Malaysia
| | - Huda T. Najim
- Department of Biomedical Engineering, University of Technology, Baghdad, Iraq
| | - Mayada Taher
- Department of Laser and Optoelectronics Engineering, University of Technology, Baghdad, Iraq
| |
Collapse
|
12
|
Fontecave-Jallon J, Haouas A, Tanguy S. Abdominal cardiovascular sound recording and analysis using cardio-microphones. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:820-823. [PMID: 36086057 DOI: 10.1109/embc48229.2022.9870910] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
In view of using abdominal microphones for fetal heart rate (FHR) monitoring, the analysis of the obtained abdominal phonocardiogram (PCG) signals is complex due to many interferential noises including blood flow sounds. In order to improve the understanding of abdominal phonocardiography, a preliminary study was conducted in one healthy volunteer and designed to characterize the PCG signals all over the abdomen. Acquisitions of PCG signals in different abdominal areas were realized, synchronously with one thoracic PCG signal and one electrocardiogram signal. The analysis was carried out based on the temporal behavior, amplitude and mean pattern of each signal. The synchronized rhythmic signature of each signal confirms that the PCG signals obtained on the abdominal area are resulting from heart function. However, the abdominal PCG patterns are totally different from the thoracic PCG one, suggesting the recording of vascular blood flow sounds on the abdomen instead of cardiac valve sounds. Moreover, the abdominal signal magnitude depends on the sensor position and therefore to the size of the underlying vessel. The sounds characterization of abdominal PCG signals could help improving the processing of such signals in the purpose of FHR monitoring.
Collapse
|
13
|
Shokouhmand A, Tavassolian N. Fetal Movement Cancellation in Abdominal Electrocardiogram Recordings Using Signal-to-Signal Translation. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:2017-2020. [PMID: 36086419 DOI: 10.1109/embc48229.2022.9871826] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
This study addresses the cancellation of fetal movement in abdominal electrocardiogram (AECG) recordings through deep neural networks. For this purpose, a generative signal-to-signal translation model consisting of two coupled generators is employed to discover the relations between fetal movement-contaminated and clean AECG recordings. The model is trained on the fetal ECG synthetic database (FECGSYNDB) which provides AECG recordings from 10 pregnancies along with their ground-truth maternal and fetal ECG signals. The signals are initially segmented into 4-second segments and then fed into the network for denoising. It is demonstrated that the signal-to-signal translation method can reconstruct clean AECG signals with average mean-absolute-error (MAE), root-mean-square deviation (RMSD), and Pearson correlation coefficient (PCC) of 0.099, 0.124, and 99.12% respectively, between clean and denoised AECG signals. Furthermore, the robustness of the method to low signal-to-noise ratio (SNR) input values is shown by an RMSD range of (0.047, 0.352) for SNR values within the range of (-3, 3) dB. Clinical Relevance- The proposed framework allows for the denoising of abdominal ECG signals for non-invasive fetal heart rate monitoring. The approach is accurate due to the use of advanced neural network techniques.
Collapse
|
14
|
Mertes G, Long Y, Liu Z, Li Y, Yang Y, Clifton DA. A Deep Learning Approach for the Assessment of Signal Quality of Non-Invasive Foetal Electrocardiography. SENSORS (BASEL, SWITZERLAND) 2022; 22:3303. [PMID: 35591004 PMCID: PMC9103336 DOI: 10.3390/s22093303] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/13/2021] [Revised: 05/28/2021] [Accepted: 06/01/2021] [Indexed: 06/15/2023]
Abstract
Non-invasive foetal electrocardiography (NI-FECG) has become an important prenatal monitoring method in the hospital. However, due to its susceptibility to non-stationary noise sources and lack of robust extraction methods, the capture of high-quality NI-FECG remains a challenge. Recording waveforms of sufficient quality for clinical use typically requires human visual inspection of each recording. A Signal Quality Index (SQI) can help to automate this task but, contrary to adult ECG, work on SQIs for NI-FECG is sparse. In this paper, a multi-channel signal quality classifier for NI-FECG waveforms is presented. The model can be used during the capture of NI-FECG to assist technicians to record high-quality waveforms, which is currently a labour-intensive task. A Convolutional Neural Network (CNN) is trained to distinguish between NI-FECG segments of high and low quality. NI-FECG recordings with one maternal channel and three abdominal channels were collected from 100 subjects during a routine hospital screening (102.6 min of data). The model achieves an average 10-fold cross-validated AUC of 0.95 ± 0.02. The results show that the model can reliably assess the FECG signal quality on our dataset. The proposed model can improve the automated capture and analysis of NI-FECG as well as reduce technician labour time.
Collapse
Affiliation(s)
- Gert Mertes
- Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford OX1 2JD, UK; (G.M.); (Z.L.); (D.A.C.)
- Oxford Suzhou Centre for Advanced Research, Suzhou 215123, China
| | - Yuan Long
- Department of Cardiovascular Medicine, Wuhan Children’s Hospital (Wuhan Maternal and Child Healthcare Hospital), Huazhong University of Science and Technology, Wuhan 430015, China;
| | - Zhangdaihong Liu
- Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford OX1 2JD, UK; (G.M.); (Z.L.); (D.A.C.)
- Oxford Suzhou Centre for Advanced Research, Suzhou 215123, China
| | - Yuhui Li
- Department of Oncology, Central Hospital of Wuhan, Huazhong University of Science and Technology, Wuhan 430014, China;
| | - Yang Yang
- Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford OX1 2JD, UK; (G.M.); (Z.L.); (D.A.C.)
- Oxford Suzhou Centre for Advanced Research, Suzhou 215123, China
| | - David A. Clifton
- Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford OX1 2JD, UK; (G.M.); (Z.L.); (D.A.C.)
- Oxford Suzhou Centre for Advanced Research, Suzhou 215123, China
| |
Collapse
|
15
|
Ribeiro M, Monteiro-Santos J, Castro L, Antunes L, Costa-Santos C, Teixeira A, Henriques TS. Non-linear Methods Predominant in Fetal Heart Rate Analysis: A Systematic Review. Front Med (Lausanne) 2021; 8:661226. [PMID: 34917624 PMCID: PMC8669823 DOI: 10.3389/fmed.2021.661226] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Accepted: 11/04/2021] [Indexed: 12/19/2022] Open
Abstract
The analysis of fetal heart rate variability has served as a scientific and diagnostic tool to quantify cardiac activity fluctuations, being good indicators of fetal well-being. Many mathematical analyses were proposed to evaluate fetal heart rate variability. We focused on non-linear analysis based on concepts of chaos, fractality, and complexity: entropies, compression, fractal analysis, and wavelets. These methods have been successfully applied in the signal processing phase and increase knowledge about cardiovascular dynamics in healthy and pathological fetuses. This review summarizes those methods and investigates how non-linear measures are related to each paper's research objectives. Of the 388 articles obtained in the PubMed/Medline database and of the 421 articles in the Web of Science database, 270 articles were included in the review after all exclusion criteria were applied. While approximate entropy is the most used method in classification papers, in signal processing, the most used non-linear method was Daubechies wavelets. The top five primary research objectives covered by the selected papers were detection of signal processing, hypoxia, maturation or gestational age, intrauterine growth restriction, and fetal distress. This review shows that non-linear indices can be used to assess numerous prenatal conditions. However, they are not yet applied in clinical practice due to some critical concerns. Some studies show that the combination of several linear and non-linear indices would be ideal for improving the analysis of the fetus's well-being. Future studies should narrow the research question so a meta-analysis could be performed, probing the indices' performance.
Collapse
Affiliation(s)
- Maria Ribeiro
- Institute for Systems and Computer Engineering, Technology and Science, Porto, Portugal.,Computer Science Department, Faculty of Sciences, University of Porto, Porto, Portugal
| | - João Monteiro-Santos
- Centre for Health Technology and Services Research, Faculty of Medicine University of Porto, Porto, Portugal.,Department of Community Medicine, Information and Health Decision Sciences, Faculty of Medicine, University of Porto, Porto, Portugal
| | - Luísa Castro
- Centre for Health Technology and Services Research, Faculty of Medicine University of Porto, Porto, Portugal.,Department of Community Medicine, Information and Health Decision Sciences, Faculty of Medicine, University of Porto, Porto, Portugal.,School of Health of Polytechnic of Porto, Porto, Portugal
| | - Luís Antunes
- Institute for Systems and Computer Engineering, Technology and Science, Porto, Portugal.,Computer Science Department, Faculty of Sciences, University of Porto, Porto, Portugal
| | - Cristina Costa-Santos
- Centre for Health Technology and Services Research, Faculty of Medicine University of Porto, Porto, Portugal.,Department of Community Medicine, Information and Health Decision Sciences, Faculty of Medicine, University of Porto, Porto, Portugal
| | - Andreia Teixeira
- Centre for Health Technology and Services Research, Faculty of Medicine University of Porto, Porto, Portugal.,Department of Community Medicine, Information and Health Decision Sciences, Faculty of Medicine, University of Porto, Porto, Portugal.,Instituto Politécnico de Viana do Castelo, Viana do Castelo, Portugal
| | - Teresa S Henriques
- Centre for Health Technology and Services Research, Faculty of Medicine University of Porto, Porto, Portugal.,Department of Community Medicine, Information and Health Decision Sciences, Faculty of Medicine, University of Porto, Porto, Portugal
| |
Collapse
|
16
|
Shandhi MMH, Goldsack JC, Ryan K, Bennion A, Kotla AV, Feng A, Jiang Y, Wang WK, Hurst T, Patena J, Carini S, Chung J, Dunn J. Recent Academic Research on Clinically Relevant Digital Measures: Systematic Review. J Med Internet Res 2021; 23:e29875. [PMID: 34524089 PMCID: PMC8482196 DOI: 10.2196/29875] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2021] [Revised: 07/02/2021] [Accepted: 08/12/2021] [Indexed: 01/16/2023] Open
Abstract
Background Digital clinical measures collected via various digital sensing technologies such as smartphones, smartwatches, wearables, ingestibles, and implantables are increasingly used by individuals and clinicians to capture health outcomes or behavioral and physiological characteristics of individuals. Although academia is taking an active role in evaluating digital sensing products, academic contributions to advancing the safe, effective, ethical, and equitable use of digital clinical measures are poorly characterized. Objective We performed a systematic review to characterize the nature of academic research on digital clinical measures and to compare and contrast the types of sensors used and the sources of funding support for specific subareas of this research. Methods We conducted a PubMed search using a range of search terms to retrieve peer-reviewed articles reporting US-led academic research on digital clinical measures between January 2019 and February 2021. We screened each publication against specific inclusion and exclusion criteria. We then identified and categorized research studies based on the types of academic research, sensors used, and funding sources. Finally, we compared and contrasted the funding support for these specific subareas of research and sensor types. Results The search retrieved 4240 articles of interest. Following the screening, 295 articles remained for data extraction and categorization. The top five research subareas included operations research (research analysis; n=225, 76%), analytical validation (n=173, 59%), usability and utility (data visualization; n=123, 42%), verification (n=93, 32%), and clinical validation (n=83, 28%). The three most underrepresented areas of research into digital clinical measures were ethics (n=0, 0%), security (n=1, 0.5%), and data rights and governance (n=1, 0.5%). Movement and activity trackers were the most commonly studied sensor type, and physiological (mechanical) sensors were the least frequently studied. We found that government agencies are providing the most funding for research on digital clinical measures (n=192, 65%), followed by independent foundations (n=109, 37%) and industries (n=56, 19%), with the remaining 12% (n=36) of these studies completely unfunded. Conclusions Specific subareas of academic research related to digital clinical measures are not keeping pace with the rapid expansion and adoption of digital sensing products. An integrated and coordinated effort is required across academia, academic partners, and academic funders to establish the field of digital clinical measures as an evidence-based field worthy of our trust.
Collapse
Affiliation(s)
| | | | - Kyle Ryan
- Big Ideas Lab, Department of Biomedical Engineering, Duke University, Durham, NC, United States
| | - Alexandra Bennion
- Big Ideas Lab, Department of Biomedical Engineering, Duke University, Durham, NC, United States
| | - Aditya V Kotla
- Big Ideas Lab, Department of Biomedical Engineering, Duke University, Durham, NC, United States
| | - Alina Feng
- Big Ideas Lab, Department of Biomedical Engineering, Duke University, Durham, NC, United States
| | - Yihang Jiang
- Department of Biomedical Engineering, Duke University, Durham, NC, United States
| | - Will Ke Wang
- Department of Biomedical Engineering, Duke University, Durham, NC, United States
| | - Tina Hurst
- Activinsights Ltd, Cambridgeshire, United Kingdom
| | - John Patena
- Brown-Lifespan Center for Digital Health, Brown University, Providence, RI, United States
| | - Simona Carini
- Division of General Internal Medicine, University of California, San Francisco, CA, United States
| | - Jeanne Chung
- Digital Medicine Society, Boston, MA, United States
| | - Jessilyn Dunn
- Department of Biomedical Engineering, Duke University, Durham, NC, United States.,Department of Biostatistics & Bioinformatics, Duke University, Durham, NC, United States
| |
Collapse
|
17
|
Goda MÁ, Telek T, Kovács F. Novel Phonography-Based Measurement for Fetal Breathing Movement in the Third Trimester. SENSORS 2020; 21:s21010211. [PMID: 33396263 PMCID: PMC7794941 DOI: 10.3390/s21010211] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Revised: 12/25/2020] [Accepted: 12/27/2020] [Indexed: 12/17/2022]
Abstract
The detailed assessment of fetal breathing movement (FBM) monitoring can be a pre-indicator of many critical cases in the third trimester of pregnancy. Standard 3D ultrasound monitoring is time-consuming for FBM detection. Therefore, this type of measurement is not common. The main goal of this research is to provide a comprehensive image about FBMs, which can also have potential for application in telemedicine. Fifty pregnancies were examined by phonography, and nearly 9000 FBMs were identified. In the case of male and female fetuses, 4740 and 3100 FBM episodes were detected, respectively. The measurements proved that FBMs are well detectable in the 20-30 Hz frequency band. For these episodes, an average duration of 1.008 ± 0.13 s (p < 0.03) was measured in the third trimester. The recorded material lasted for 16 h altogether. Based on these measurements, an accurate assessment of FBMs could be performed. The epochs can be divided into smaller-episode groups separated by shorter breaks. During the pregnancy, the rate of these breaks continuously decreases, and episode groups become more contiguous. However, there are significant differences between male and female fetuses. The proportion of the episodes which were classified into minimally 10-member episode groups was 19.7% for males and only 12.1% for females, even at the end of the third trimester. In terms of FBM detection, phonography offers a novel opportunity for long-term monitoring. Combined with cardiac diagnostic methods, it can be used for fetal activity assessment in the third trimester and make measurement appreciably easier than before.
Collapse
Affiliation(s)
- Márton Áron Goda
- Faculty of Information Technology and Bionics, Pázmány Péter Catholic University, Práter utca 50/a, 1083 Budapest, Hungary;
- Correspondence:
| | - Tamás Telek
- St. Margaret Hospital, Bécsi út 132, 1032 Budapest, Hungary;
| | - Ferenc Kovács
- Faculty of Information Technology and Bionics, Pázmány Péter Catholic University, Práter utca 50/a, 1083 Budapest, Hungary;
| |
Collapse
|
18
|
Valderrama CE, Ketabi N, Marzbanrad F, Rohloff P, Clifford GD. A review of fetal cardiac monitoring, with a focus on low- and middle-income countries. Physiol Meas 2020; 41:11TR01. [PMID: 33105122 PMCID: PMC9216228 DOI: 10.1088/1361-6579/abc4c7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
There is limited evidence regarding the utility of fetal monitoring during pregnancy, particularly during labor and delivery. Developed countries rely on consensus ‘best practices’ of obstetrics and gynecology professional societies to guide their protocols and policies. Protocols are often driven by the desire to be as safe as possible and avoid litigation, regardless of the cost of downstream treatment. In high-resource settings, there may be a justification for this approach. In low-resource settings, in particular, interventions can be costly and lead to adverse outcomes in subsequent pregnancies. Therefore, it is essential to consider the evidence and cost of different fetal monitoring approaches, particularly in the context of treatment and care in low-to-middle income countries. This article reviews the standard methods used for fetal monitoring, with particular emphasis on fetal cardiac assessment, which is a reliable indicator of fetal well-being. An overview of fetal monitoring practices in low-to-middle income counties, including perinatal care access challenges, is also presented. Finally, an overview of how mobile technology may help reduce barriers to perinatal care access in low-resource settings is provided.
Collapse
Affiliation(s)
- Camilo E Valderrama
- Data Intelligence for Health Lab, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
| | | | | | | | | |
Collapse
|
19
|
Kovacs F, Goda MA, Hosszu G, Telek T. A Proposed Phonography-Based Measurement of Fetal Breathing Movement Using Segmented Structures with Frequency Splitting. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:4483-4486. [PMID: 33018990 DOI: 10.1109/embc44109.2020.9175477] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
This paper proposes a detection method of fetal breathing movement (FBM) as an important data of fetal well-being. To analyze the chaotic nature of the individual episodes, the frequency band has been split into single test frequencies in order to find its starting point (SP) as a signal free (quiet) zone. Computing some features of the signal the sound will be distinguishable from the disturbing signals as hiccups, body's rotation and limb movements or even additional noises of maternal heart beats. The SPs of the episodes are characterized by an approximation process in order to select the real ones.Clinical relevance- The method is an irradiation free measurement, carried out on the maternal abdomen. Furthermore, connected with the fetal phonocardiographic (fPCG) monitoring the method offers a non-invasive way for FBM detection applicable also at home. More than 50 pregnancies were examined with the proposed method for at least for 20-min with synchronous measurements by the proposed phonographic device and a 3D ultrasound machine in the third trimester.
Collapse
|
20
|
Tomassini S, Sbrollini A, Strazza A, Sameni R, Marcantoni I, Morettini M, Burattini L. AdvFPCG-Delineator: Advanced delineator for fetal phonocardiography. Biomed Signal Process Control 2020. [DOI: 10.1016/j.bspc.2020.102021] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
21
|
Dia N, Fontecave-Jallon J, Gumery PY, Rivet B. Fetal heart rate estimation from a single phonocardiogram signal using non-negative matrix factorization. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:5983-5986. [PMID: 31947210 DOI: 10.1109/embc.2019.8857220] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Fetal heart rate (FHR) is an important characteristic in fetal well-being follow-up. It is classically estimated using the cardiotocogram (CTG) non-invasive reference technique. However, this latter presents some significant drawbacks. An alternative non-invasive solution based on the fetal phonocardiogram (fetal PCG) can be used. But most of proposed methods based on the PCG signal need to detect and to label the fetal cardiac S1 and S2 sounds, which may be a difficult task in certain conditions. Therefore, in this paper, we propose a new methodology for FHR estimation from fetal PCG with one single cardio-microphone and without the distinction constraint of heart sounds. The method is based on the non-negative matrix factorization (NMF) applied on the spectrogram of fetal PCG considered as a source-filter model. The proposed method provides satisfactory results on a preliminary dataset of abdominal PCG signals. When compared to the reference CTG, correlation on FHR estimations between PCG and CTG is around 90%.
Collapse
|
22
|
Charlier P, Herman C, Rochedreux N, Logier R, Garabedian C, Debarge V, Jonckheere JD. AcCorps: A low-cost 3D printed stethoscope for fetal phonocardiography. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2019; 2019:52-55. [PMID: 31945843 DOI: 10.1109/embc.2019.8856575] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
The analysis of fetal heart rate provides valuable information regarding the fetus wellbeing. Fetal phonocardiography is a low-cost and passive method allowing the acquisition of fetal heart rate by recording acoustic vibrations on the mother's abdomen. However, most of available stethoscopes are not optimized for a robust acquisition of fetal heart sound. In this publication, we investigated a new design of low-cost and 3D printed stethoscope. This device was optimized to provide an acoustic amplification especially in the low-frequency band which corresponds to the fetal heart sounds. This device was tested i) in silico, ii) on a test bench and iii) on 5 pregnant volunteers.
Collapse
|
23
|
Cheema A, Singh M. An application of phonocardiography signals for psychological stress detection using non-linear entropy based features in empirical mode decomposition domain. Appl Soft Comput 2019. [DOI: 10.1016/j.asoc.2019.01.006] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
24
|
Cheema A, Singh M. Psychological stress detection using phonocardiography signal: An empirical mode decomposition approach. Biomed Signal Process Control 2019. [DOI: 10.1016/j.bspc.2018.12.028] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
25
|
Jaros R, Martinek R, Kahankova R. Non-Adaptive Methods for Fetal ECG Signal Processing: A Review and Appraisal. SENSORS 2018; 18:s18113648. [PMID: 30373259 PMCID: PMC6263968 DOI: 10.3390/s18113648] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/28/2018] [Revised: 10/18/2018] [Accepted: 10/24/2018] [Indexed: 11/16/2022]
Abstract
Fetal electrocardiography is among the most promising methods of modern electronic fetal monitoring. However, before they can be fully deployed in the clinical practice as a gold standard, the challenges associated with the signal quality must be solved. During the last two decades, a great amount of articles dealing with improving the quality of the fetal electrocardiogram signal acquired from the abdominal recordings have been introduced. This article aims to present an extensive literature survey of different non-adaptive signal processing methods applied for fetal electrocardiogram extraction and enhancement. It is limiting that a different non-adaptive method works well for each type of signal, but independent component analysis, principal component analysis and wavelet transforms are the most commonly published methods of signal processing and have good accuracy and speed of algorithms.
Collapse
Affiliation(s)
- Rene Jaros
- Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17. listopadu 15, 708 33 Ostrava, Czech Republic.
| | - Radek Martinek
- Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17. listopadu 15, 708 33 Ostrava, Czech Republic.
| | - Radana Kahankova
- Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17. listopadu 15, 708 33 Ostrava, Czech Republic.
| |
Collapse
|
26
|
Mubarak QUA, Akram MU, Shaukat A, Hussain F, Khawaja SG, Butt WH. Analysis of PCG signals using quality assessment and homomorphic filters for localization and classification of heart sounds. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2018; 164:143-157. [PMID: 30195422 DOI: 10.1016/j.cmpb.2018.07.006] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2018] [Revised: 06/26/2018] [Accepted: 07/16/2018] [Indexed: 05/21/2023]
Abstract
BACKGROUND AND OBJECTIVE Accurate localization of heart beats in phonocardiogram (PCG) signal is very crucial for correct segmentation and classification of heart sounds into S1 and S2. This task becomes challenging due to inclusion of noise in acquisition process owing to number of different factors. In this paper we propose a system for heart sound localization and classification into S1 and S2. The proposed system introduces the concept of quality assessment before localization, feature extraction and classification of heart sounds. METHODS The signal quality is assessed by predefined criteria based upon number of peaks and zero crossing of PCG signal. Once quality assessment is performed, then heart beats within PCG signal are localized, which is done by envelope extraction using homomorphic envelogram and finding prominent peaks. In order to classify localized peaks into S1 and S2, temporal and time-frequency based statistical features have been used. Support Vector Machine using radial basis function kernel is used for classification of heart beats into S1 and S2 based upon extracted features. The performance of the proposed system is evaluated using Accuracy, Sensitivity, Specificity, F-measure and Total Error. The dataset provided by PASCAL classifying heart sound challenge is used for testing. RESULTS Performance of system is significantly improved by quality assessment. Results shows that proposed Localization algorithm achieves accuracy up to 97% and generates smallest total average error among top 3 challenge participants. The classification algorithm achieves accuracy up to 91%. CONCLUSION The system provides firm foundation for the detection of normal and abnormal heart sounds for cardiovascular disease detection.
Collapse
Affiliation(s)
- Qurat-Ul-Ain Mubarak
- Department of Computer & Software Engineering, College of Electrical & Mechanical Engineering, National University of Sciences and Technology, Islamabad, Pakistan.
| | - Muhammad Usman Akram
- Department of Computer & Software Engineering, College of Electrical & Mechanical Engineering, National University of Sciences and Technology, Islamabad, Pakistan
| | - Arslan Shaukat
- Department of Computer & Software Engineering, College of Electrical & Mechanical Engineering, National University of Sciences and Technology, Islamabad, Pakistan
| | - Farhan Hussain
- Department of Computer & Software Engineering, College of Electrical & Mechanical Engineering, National University of Sciences and Technology, Islamabad, Pakistan
| | - Sajid Gul Khawaja
- Department of Computer & Software Engineering, College of Electrical & Mechanical Engineering, National University of Sciences and Technology, Islamabad, Pakistan
| | - Wasi Haider Butt
- Department of Computer & Software Engineering, College of Electrical & Mechanical Engineering, National University of Sciences and Technology, Islamabad, Pakistan
| |
Collapse
|
27
|
Validation of beat by beat fetal heart signals acquired from four-channel fetal phonocardiogram with fetal electrocardiogram in healthy late pregnancy. Sci Rep 2018; 8:13635. [PMID: 30206289 PMCID: PMC6134006 DOI: 10.1038/s41598-018-31898-1] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2018] [Accepted: 08/29/2018] [Indexed: 11/08/2022] Open
Abstract
Fetal heart rate monitoring is an essential obstetric procedure, however, false-positive results cause unnecessary obstetric interventions and healthcare cost. In this study, we propose a low cost and non-invasive fetal phonocardiography based signal system to measure the fetal heart sounds and fetal heart rate. Phonocardiogram (PCG) signals contain acoustic information reflecting the contraction and relaxation of the heart. We have developed a four-channel recording device with four separated piezoelectric sensors harnessed by a cloth sheet to record abdominal phonogram signals. A multi-lag covariance matrix based eigenvalue decomposition technique was used to extract fetal and maternal heart sounds as well as maternal breathing movement. In order to validate the fetal heart sounds extracted by PCG signal processing, 10 minutes' simultaneous recordings of fetal Electrocardiogram (fECG) and abdominal phonogram from 15 pregnant women (27 ± 5-year-old) with fetal gestation ages between 33 and 40 weeks were obtained and processed. Highly significant (p < 0.01) correlation (r = 0.96; N = 270) was found between beat to beat fetal heart rate (FHRECG) from fECG and the same (FHRPCG) from fetal PCG signals. Bland-Altman plot of FHRECG and FHRPCG shows good agreement (<5% difference). We conclude that the proposed beat to beat fetal heart rate measurement system would be useful for monitoring fetal neurological wellbeing as a better alternative to traditional cardiotocogram based antenatal fetal heart rate monitoring.
Collapse
|
28
|
Marzbanrad F, Stroux L, Clifford GD. Cardiotocography and beyond: a review of one-dimensional Doppler ultrasound application in fetal monitoring. Physiol Meas 2018; 39:08TR01. [PMID: 30027897 PMCID: PMC6237616 DOI: 10.1088/1361-6579/aad4d1] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
One-dimensional Doppler ultrasound (1D-DUS) provides a low-cost and simple method for acquiring a rich signal for use in cardiovascular screening. However, despite the use of 1D-DUS in cardiotocography (CTG) for decades, there are still challenges that limit the effectiveness of its users in reducing fetal and neonatal morbidities and mortalities. This is partly due to the noisy, transient, complex and nonstationary nature of the 1D-DUS signals. Current challenges also include lack of efficient signal quality metrics, insufficient signal processing techniques for extraction of fetal heart rate and other vital parameters with adequate temporal resolution, and lack of appropriate clinical decision support for CTG and Doppler interpretation. Moreover, the almost complete lack of open research in both hardware and software in this field, as well as commercial pressures to market the much more expensive and difficult to use Doppler imaging devices, has hampered innovation. This paper reviews the basics of fetal cardiac function, 1D-DUS signal generation and processing, its application in fetal monitoring and assessment of fetal development and wellbeing. It also provides recommendations for future development of signal processing and modeling approaches, to improve the application of 1D-DUS in fetal monitoring, as well as the need for annotated open databases.
Collapse
Affiliation(s)
- Faezeh Marzbanrad
- Department of Electrical and Computer Systems Engineering, Monash University, Clayton, VIC, Australia
| | | | | |
Collapse
|
29
|
Zhong W, Liao L, Guo X, Wang G. A deep learning approach for fetal QRS complex detection. Physiol Meas 2018; 39:045004. [DOI: 10.1088/1361-6579/aab297] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
30
|
Romano M, Bifulco P, Ponsiglione A, Gargiulo G, Amato F, Cesarelli M. Evaluation of floatingline and foetal heart rate variability. Biomed Signal Process Control 2018. [DOI: 10.1016/j.bspc.2017.07.018] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
31
|
Martinek R, Kahankova R, Nazeran H, Konecny J, Jezewski J, Janku P, Bilik P, Zidek J, Nedoma J, Fajkus M. Non-Invasive Fetal Monitoring: A Maternal Surface ECG Electrode Placement-Based Novel Approach for Optimization of Adaptive Filter Control Parameters Using the LMS and RLS Algorithms. SENSORS 2017; 17:s17051154. [PMID: 28534810 PMCID: PMC5470900 DOI: 10.3390/s17051154] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/24/2017] [Revised: 05/05/2017] [Accepted: 05/12/2017] [Indexed: 11/16/2022]
Abstract
This paper is focused on the design, implementation and verification of a novel method for the optimization of the control parameters (such as step size μ and filter order N) of LMS and RLS adaptive filters used for noninvasive fetal monitoring. The optimization algorithm is driven by considering the ECG electrode positions on the maternal body surface in improving the performance of these adaptive filters. The main criterion for optimal parameter selection was the Signal-to-Noise Ratio (SNR). We conducted experiments using signals supplied by the latest version of our LabVIEW-Based Multi-Channel Non-Invasive Abdominal Maternal-Fetal Electrocardiogram Signal Generator, which provides the flexibility and capability of modeling the principal distribution of maternal/fetal ECGs in the human body. Our novel algorithm enabled us to find the optimal settings of the adaptive filters based on maternal surface ECG electrode placements. The experimental results further confirmed the theoretical assumption that the optimal settings of these adaptive filters are dependent on the ECG electrode positions on the maternal body, and therefore, we were able to achieve far better results than without the use of optimization. These improvements in turn could lead to a more accurate detection of fetal hypoxia. Consequently, our approach could offer the potential to be used in clinical practice to establish recommendations for standard electrode placement and find the optimal adaptive filter settings for extracting high quality fetal ECG signals for further processing. Ultimately, diagnostic-grade fetal ECG signals would ensure the reliable detection of fetal hypoxia.
Collapse
Affiliation(s)
- Radek Martinek
- Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, 70833 Ostrava, Czech Republic.
| | - Radana Kahankova
- Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, 70833 Ostrava, Czech Republic.
| | - Homer Nazeran
- Department of Electrical and Computer Engineering, University of Texas El Paso, 500 W University Ave, El Paso, TX 79968, USA.
| | - Jaromir Konecny
- Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, 70833 Ostrava, Czech Republic.
| | - Janusz Jezewski
- Institute of Medical Technology and Equipment ITAM, 118 Roosevelt Str., 41-800 Zabrze, Poland.
| | - Petr Janku
- Department of Obstetrics and Gynecology, Masaryk University and University Hospital Brno, Jihlavska 20, 625 00 Brno, Czech Republic.
| | - Petr Bilik
- Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, 70833 Ostrava, Czech Republic.
| | - Jan Zidek
- Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, 70833 Ostrava, Czech Republic.
| | - Jan Nedoma
- Department of Telecommunications, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, 70833 Ostrava, Czech Republic.
| | - Marcel Fajkus
- Department of Telecommunications, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, 70833 Ostrava, Czech Republic.
| |
Collapse
|
32
|
Martinek R, Nedoma J, Fajkus M, Kahankova R, Konecny J, Janku P, Kepak S, Bilik P, Nazeran H. A Phonocardiographic-Based Fiber-Optic Sensor and Adaptive Filtering System for Noninvasive Continuous Fetal Heart Rate Monitoring. SENSORS 2017; 17:s17040890. [PMID: 28420215 PMCID: PMC5426540 DOI: 10.3390/s17040890] [Citation(s) in RCA: 63] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/05/2017] [Revised: 03/28/2017] [Accepted: 04/12/2017] [Indexed: 11/21/2022]
Abstract
This paper focuses on the design, realization, and verification of a novel phonocardiographic- based fiber-optic sensor and adaptive signal processing system for noninvasive continuous fetal heart rate (fHR) monitoring. Our proposed system utilizes two Mach-Zehnder interferometeric sensors. Based on the analysis of real measurement data, we developed a simplified dynamic model for the generation and distribution of heart sounds throughout the human body. Building on this signal model, we then designed, implemented, and verified our adaptive signal processing system by implementing two stochastic gradient-based algorithms: the Least Mean Square Algorithm (LMS), and the Normalized Least Mean Square (NLMS) Algorithm. With this system we were able to extract the fHR information from high quality fetal phonocardiograms (fPCGs), filtered from abdominal maternal phonocardiograms (mPCGs) by performing fPCG signal peak detection. Common signal processing methods such as linear filtering, signal subtraction, and others could not be used for this purpose as fPCG and mPCG signals share overlapping frequency spectra. The performance of the adaptive system was evaluated by using both qualitative (gynecological studies) and quantitative measures such as: Signal-to-Noise Ratio—SNR, Root Mean Square Error—RMSE, Sensitivity—S+, and Positive Predictive Value—PPV.
Collapse
Affiliation(s)
- Radek Martinek
- Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, Ostrava 70833, Czech Republic.
| | - Jan Nedoma
- Department of Telecommunications, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, Ostrava 70833, Czech Republic.
| | - Marcel Fajkus
- Department of Telecommunications, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, Ostrava 70833, Czech Republic.
| | - Radana Kahankova
- Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, Ostrava 70833, Czech Republic.
| | - Jaromir Konecny
- Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, Ostrava 70833, Czech Republic.
| | - Petr Janku
- Department of Obstetrics and Gynecology, Masaryk University and University Hospital Brno, Jihlavska 20, 625 00 Brno, Czech Republic.
| | - Stanislav Kepak
- Department of Telecommunications, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, Ostrava 70833, Czech Republic.
| | - Petr Bilik
- Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, Ostrava 70833, Czech Republic.
| | - Homer Nazeran
- Department of Electrical and Computer Engineering, University of Texas El Paso, 500 W University Ave, El Paso, TX 79968, USA.
| |
Collapse
|
33
|
Chetlur Adithya P, Sankar R, Moreno WA, Hart S. Trends in fetal monitoring through phonocardiography: Challenges and future directions. Biomed Signal Process Control 2017. [DOI: 10.1016/j.bspc.2016.11.007] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
34
|
Behar J, Andreotti F, Zaunseder S, Oster J, Clifford GD. A practical guide to non-invasive foetal electrocardiogram extraction and analysis. Physiol Meas 2016; 37:R1-R35. [DOI: 10.1088/0967-3334/37/5/r1] [Citation(s) in RCA: 75] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
35
|
Fetal Heart Rate Monitoring from Phonocardiograph Signal Using Repetition Frequency of Heart Sounds. JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING 2016. [DOI: 10.1155/2016/2404267] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
As a passive, harmless, and low-cost diagnosis tool, fetal heart rate (FHR) monitoring based on fetal phonocardiography (fPCG) signal is alternative to ultrasonographic cardiotocography. Previous fPCG-based methods commonly relied on the time difference of detected heart sound bursts. However, the performance is unavoidable to degrade due to missed heart sounds in very low signal-to-noise ratio environments. This paper proposes a FHR monitoring method using repetition frequency of heart sounds. The proposed method can track time-varying heart rate without both heart sound burst identification and denoising. The average accuracy rate comparison to benchmark is 88.3% as the SNR ranges from −4.4 dB to −26.7 dB.
Collapse
|
36
|
Rooijakkers MJ, Rabotti C, de Lau H, Oei SG, Bergmans JWM, Mischi M. Feasibility Study of a New Method for Low-Complexity Fetal Movement Detection From Abdominal ECG Recordings. IEEE J Biomed Health Inform 2015; 20:1361-8. [PMID: 26151947 DOI: 10.1109/jbhi.2015.2452266] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Fetal movement counting can provide valuable information on the fetal health, as a strong decrease in the number of movements can be seen as a precursor to fetal death. Typically, assessment of fetal health by fetal movement counting relies on the maternal perception of fetal activity. The percentage of detected movements is strongly subject dependent and with undivided attention of the mother varies between 37% and 88%. Various methods to assist in fetal movement detection exist based on a wide spectrum of measurement techniques. However, these are unsuitable for ambulatory or long-term observation. In this paper, a novel low-complexity method for fetal movement detection is presented based on amplitude and shape changes in the abdominally recorded fetal ECG. This method was compared to a state-of-the-art method from the literature. Using ultrasound-based movement annotations as ground truth, the presented method outperforms the state-of-the-art abdominal-ECG based method, with a sensitivity, specificity, and accuracy of 56%, 68%, and 63%, respectively. Additionally, a significant reduction in algorithm complexity is achieved, possibly enabling continuous ambulatory fetal movement detection and early detection of reduced fetal motility.
Collapse
|
37
|
Sun S. An innovative intelligent system based on automatic diagnostic feature extraction for diagnosing heart diseases. Knowl Based Syst 2015. [DOI: 10.1016/j.knosys.2014.12.001] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
38
|
Hu Y, Kim EG, Cao G, Liu S, Xu Y. Physiological acoustic sensing based on accelerometers: a survey for mobile healthcare. Ann Biomed Eng 2014; 42:2264-77. [PMID: 25234130 DOI: 10.1007/s10439-014-1111-8] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2014] [Accepted: 09/05/2014] [Indexed: 02/07/2023]
Abstract
This paper reviews the applications of accelerometers on the detection of physiological acoustic signals such as heart sounds, respiratory sounds, and gastrointestinal sounds. These acoustic signals contain a rich reservoir of vital physiological and pathological information. Accelerometer-based systems enable continuous, mobile, low-cost, and unobtrusive monitoring of physiological acoustic signals and thus can play significant roles in the emerging mobile healthcare. In this review, we first briefly explain the operation principle of accelerometers and specifications that are important for mobile healthcare. Applications of accelerometer-based monitoring systems are then presented. Next, we review a variety of accelerometers which have been reported in literatures for physiological acoustic sensing, including both commercial products and research prototypes. Finally, we discuss some challenges and our vision for future development.
Collapse
Affiliation(s)
- Yating Hu
- Engineering Technology, Middle Tennessee State University, Murfreesboro, TN, 37132, USA
| | | | | | | | | |
Collapse
|
39
|
Sun S, Jiang Z, Wang H, Fang Y. Automatic moment segmentation and peak detection analysis of heart sound pattern via short-time modified Hilbert transform. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2014; 114:219-230. [PMID: 24657095 DOI: 10.1016/j.cmpb.2014.02.004] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/02/2013] [Revised: 01/05/2014] [Accepted: 02/11/2014] [Indexed: 06/03/2023]
Abstract
This paper proposes a novel automatic method for the moment segmentation and peak detection analysis of heart sound (HS) pattern, with special attention to the characteristics of the envelopes of HS and considering the properties of the Hilbert transform (HT). The moment segmentation and peak location are accomplished in two steps. First, by applying the Viola integral waveform method in the time domain, the envelope (E(T)) of the HS signal is obtained with an emphasis on the first heart sound (S1) and the second heart sound (S2). Then, based on the characteristics of the E(T) and the properties of the HT of the convex and concave functions, a novel method, the short-time modified Hilbert transform (STMHT), is proposed to automatically locate the moment segmentation and peak points for the HS by the zero crossing points of the STMHT. A fast algorithm for calculating the STMHT of E(T) can be expressed by multiplying the E(T) by an equivalent window (W(E)). According to the range of heart beats and based on the numerical experiments and the important parameters of the STMHT, a moving window width of N=1s is validated for locating the moment segmentation and peak points for HS. The proposed moment segmentation and peak location procedure method is validated by sounds from Michigan HS database and sounds from clinical heart diseases, such as a ventricular septal defect (VSD), an aortic septal defect (ASD), Tetralogy of Fallot (TOF), rheumatic heart disease (RHD), and so on. As a result, for the sounds where S2 can be separated from S1, the average accuracies achieved for the peak of S1 (AP₁), the peak of S2 (AP₂), the moment segmentation points from S1 to S2 (AT₁₂) and the cardiac cycle (ACC) are 98.53%, 98.31% and 98.36% and 97.37%, respectively. For the sounds where S1 cannot be separated from S2, the average accuracies achieved for the peak of S1 and S2 (AP₁₂) and the cardiac cycle ACC are 100% and 96.69%.
Collapse
Affiliation(s)
- Shuping Sun
- Department of Mechanical Engineering, Yamaguchi University, Tokiwadai 2-16-1, Ube, Yamaguchi, Japan.
| | - Zhongwei Jiang
- Department of Mechanical Engineering, Yamaguchi University, Tokiwadai 2-16-1, Ube, Yamaguchi, Japan
| | - Haibin Wang
- School of Electrical and Information Engineering, Xihua University, Chengdu 610039, China
| | - Yu Fang
- School of Electrical and Information Engineering, Xihua University, Chengdu 610039, China
| |
Collapse
|
40
|
Chourasia VS, Tiwari AK, Gangopadhyay R. Interval type-2 fuzzy logic based antenatal care system using phonocardiography. Appl Soft Comput 2014. [DOI: 10.1016/j.asoc.2013.08.016] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
41
|
Cesarelli M, Ruffo M, Romano M, Bifulco P. Simulation of foetal phonocardiographic recordings for testing of FHR extraction algorithms. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2012; 107:513-523. [PMID: 22178069 DOI: 10.1016/j.cmpb.2011.11.008] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/15/2011] [Revised: 11/21/2011] [Accepted: 11/27/2011] [Indexed: 05/31/2023]
Abstract
A valuable alternative to traditional diagnostic tools, such as ultrasonographic cardiotocography, to monitor general foetal well-being by means of foetal heart rate analysis is foetal phonocardiography, a passive and low cost recording of foetal heart sounds. In this paper, it is presented a simulator software of foetal phonocardiographic signals relative to different foetal states and recording conditions (for example different kinds and levels of noise). Before developing the software, a data collection pilot study was conducted with the purpose of specifically identifying the characteristics of the waveforms of the foetal and maternal heart sounds, since the available literature is not rigorous in this area. The developed software, due to the possibility to simulate different physiological and pathological foetal conditions and recording situations simply modifying some system parameters, can be useful as a teaching tool for demonstration to medical students and others and also for testing and assessment of foetal heart rate extraction algorithms from foetal phonocardiographic (fPCG) recordings. On this purpose, the simulator software was used to test an algorithm developed by the authors for foetal heart rate extraction considering different foetal heart rate parameters and signal to noise ratio values. Our tests demonstrated that simulated fPCG signals are very close to real fPCG recordings.
Collapse
Affiliation(s)
- M Cesarelli
- Department of Biomedical, Electronic and Telecommunication Engineering, University Federico II, via Claudio no. 21, Naples, Italy.
| | | | | | | |
Collapse
|