1
|
Zhao K, Zhang Z, Zhou Y, Lin X. Ag-CeO 2 Based on Electrochemical Sensor for High-Efficient On-Site Detection of Nitrite in Aquaculture Water and Beverages. Molecules 2024; 29:2644. [PMID: 38893519 PMCID: PMC11173993 DOI: 10.3390/molecules29112644] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2024] [Revised: 05/28/2024] [Accepted: 05/28/2024] [Indexed: 06/21/2024] Open
Abstract
Nitrite is one of the most common nitrogenous compounds, which is not only an important indicator of aquaculture water but also widely used as a food additive. Its potential toxicity poses a huge threat to aquatic products and human health. Therefore, it is important to develop a convenient and rapid sensor for the high-efficient onsite detection of nitrite. In this work, a novel electrochemical sensor was developed for the qualitative and quantitative analysis of nitrite. The developed nitrite electrochemical detection system is easily applied in onsite detection. The electrochemical working electrode was constructed based on the combination of Ag-CeO2 and conductive carbon paste (CPE) with excellent electrocatalysis activity and rapid electron transfer ability. By the application of the developed system and under the optimal conditions, the linear range was from 40.0 μM to 500.0 μM, and the detection limit was reduced to 4.3 μM. The recovery was between 92.1% and 108.1%, and the relative standard deviations (RSDs) were 0.49%~9.31%. The sensor exhibited superior reproducibility, high stability sensitivity, and anti-interference ability, confirming its effectiveness for nitrite analysis. Finally, the developed electrochemical sensor was successfully applied to detect nitrite in beverages and aquaculture water samples, indicating that this approach has great potential in onsite food testing and environmental monitoring.
Collapse
Affiliation(s)
- Kunmeng Zhao
- College of Chemical Engineering, Huaqiao University, Xiamen 361021, China
- College of Materials Science and Engineering, Huaqiao University, Xiamen 361021, China
| | - Ziyao Zhang
- College of Chemical Engineering, Huaqiao University, Xiamen 361021, China
| | - Yihui Zhou
- College of Chemical Engineering, Huaqiao University, Xiamen 361021, China
| | - Xuexia Lin
- College of Chemical Engineering, Huaqiao University, Xiamen 361021, China
- College of Materials Science and Engineering, Huaqiao University, Xiamen 361021, China
| |
Collapse
|
2
|
Baye AF, Bandal HA, Kim H. FeC x-coated biochar nanosheets as efficient bifunctional catalyst for electrochemical detection and reduction of 4-nitrophenol. ENVIRONMENTAL RESEARCH 2024; 246:118071. [PMID: 38163546 DOI: 10.1016/j.envres.2023.118071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 12/10/2023] [Accepted: 12/26/2023] [Indexed: 01/03/2024]
Abstract
Herein, we present the exceptional performance of FeCx-coated carbon sheets (FC) derived from the pyrolysis of waste biomass as a bifunctional catalyst for electrochemical detection and catalytic reduction of 4-nitrophenol (4-NP). Despite having a lower surface area, larger particle size, and lesser N content, the FC material prepared at a calcination temperature of 900 °C (FC900) outperforms the other samples. Deeper investigations revealed that the FC900 efficiently facilitates the charge transfer process and enhances the diffusion rate of 4-NP, leading to increased surface coverage of 4-NP on the surface of FC900. Additionally, relatively weaker interactions between 4-NP and FC900 allow the facile adsorption and desorption of reaction intermediates. Due to the synergetic interplay of these factors, FC900 exhibited a linear response to changes in 4-NP concentration from 1 μM to 100 μM with a low limit of detection (LOD) of 84 nM (S/N = 3) and high sensitivity of 12.15 μA μM-1 cm-2. Importantly, it selectively detects 4-NP in the presence of five times more concentrated 2-aminophenol, 4-aminophenol, catechol, resorcinol, and hydroquinone and ten times more concentrated metal salts such as Na2SO4. NaNO3, KCl, CuCl2, and CaCl2. Moreover, FC900 can accurately detect micromolar levels of 4-NP in river water with high recovery values (99.8-103.5 %). In addition, FC900 exhibited outstanding catalytic activity in reducing 4-NP to 4-aminophenol (4-AP), achieving complete conversion within 8 min with a high-rate constant of 0.42 min-1. FC900 also shows high recyclability in six consecutive catalytic reactions due to Fe magnetic property.
Collapse
Affiliation(s)
- Anteneh F Baye
- Department of Energy Science and Technology, Environmental Waste Recycle Institute, Myongji University, Yongin, Gyeonggi-do, 17058, Republic of Korea.
| | - Harshad A Bandal
- Department of Energy Science and Technology, Environmental Waste Recycle Institute, Myongji University, Yongin, Gyeonggi-do, 17058, Republic of Korea.
| | - Hern Kim
- Department of Energy Science and Technology, Environmental Waste Recycle Institute, Myongji University, Yongin, Gyeonggi-do, 17058, Republic of Korea.
| |
Collapse
|
3
|
Wang X, Karaman C, Zhang Y, Xia C. Graphene oxide/cellulose nanofibril composite: A high-performance catalyst for the fabrication of an electrochemical sensor for quantification of p-nitrophenol, a hazardous water pollutant. CHEMOSPHERE 2023; 331:138813. [PMID: 37127202 DOI: 10.1016/j.chemosphere.2023.138813] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Revised: 03/17/2023] [Accepted: 04/28/2023] [Indexed: 05/03/2023]
Abstract
The detection and quantification of p-Nitrophenol (p-NP) in environmental samples are important for understanding the extent and impact of environmental pollution, protecting human health, ensuring regulatory compliance, and guiding remediation efforts. The main objective of this work was to investigate the electrochemical performance of a graphene oxide/cellulose nanofibril composite (GO/CNF) modified carbon paste electrode (GO/CNF/CPE) for the sensitive and reliable detection of p-nitrophenol in water samples. The transmission electron microscopy (TEM) technique was employed to enlighten the structure of nanocomposites. The electrochemical behavior of the fabricated electrochemical sensor was characterized via differential pulse voltammetry (DPV), linear sweep voltammetry (LSV), and electrochemical impedance spectroscopy (EIS). Under optimized analytical conditions, the peak current of the analyte showed a wide linear relationship with its concentration in a range of 3.0 nM-210 μM with a low amount of the limit of detection (LOD) value of 0.8 nM determined by the DPV method. The proposed electrochemical sensor demonstrated excellent sensitivity, selectivity, and accuracy metrics in real sample analysis of p-nitrophenol.
Collapse
Affiliation(s)
- Xuan Wang
- Jiangsu Co-Innovation Center of Efficient Processing and Utilization of Forest Resources, International Innovation Center for Forest Chemicals and Materials, College of Materials Science and Engineering, Nanjing Forestry University, Nanjing, Jiangsu, 210037, China
| | - Ceren Karaman
- Department of Electricity and Energy, Vocational School of Technical Sciences, Akdeniz University, Antalya, 07070, Turkey; School of Engineering, Lebanese American University, Byblos, Lebanon.
| | - Yaoli Zhang
- Jiangsu Co-Innovation Center of Efficient Processing and Utilization of Forest Resources, International Innovation Center for Forest Chemicals and Materials, College of Materials Science and Engineering, Nanjing Forestry University, Nanjing, Jiangsu, 210037, China
| | - Changlei Xia
- Jiangsu Co-Innovation Center of Efficient Processing and Utilization of Forest Resources, International Innovation Center for Forest Chemicals and Materials, College of Materials Science and Engineering, Nanjing Forestry University, Nanjing, Jiangsu, 210037, China.
| |
Collapse
|
4
|
Ansari AA, Muthumareeswaran M, Lv R. Coordination chemistry of the host matrices with dopant luminescent Ln3+ ion and their impact on luminescent properties. Coord Chem Rev 2022. [DOI: 10.1016/j.ccr.2022.214584] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
5
|
Li G, Yuan B, Chen S, Gan L, Xu C. Covalent Organic Frameworks-TpPa-1 as an Emerging Platform for Electrochemical Sensing. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:nano12172953. [PMID: 36079991 PMCID: PMC9457582 DOI: 10.3390/nano12172953] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2022] [Revised: 08/19/2022] [Accepted: 08/22/2022] [Indexed: 06/07/2023]
Abstract
Covalent organic frameworks (COFs) are a new type of metal-free porous architecture with a well-designed pore structure and high stability. Here an efficient electrochemical sensing platform was demonstrated based on COFs TpPa-1 constructed by 1,3,5-triformylphloroglucinol (Tp) with p-phenylenediamine (Pa-1), which possesses abundant nitrogen and oxo-functionalities. COFs TpPa-1 exhibited good water dispersibility and strong adsorption affinities for Pd2+ and thus was used as loading support to modify Pd2+. The Pd2+-modified COFs TpPa-1 electrode (Pd2+/COFs) showed high electrocatalytic activity for both hydrazine oxidation reaction and nitrophenol reduction reaction. In addition, TpPa-1-derived nitrogen-doped carbon presented high activity for the electro-oxidation of reduced glutathione (GSH), and sensitive electrochemical detection of GSH was achieved. The presented COFs TpPa-1 can be utilized as a precursor as well as support for anchoring electro-active molecules and nanoparticles, which will be useful for electrochemical sensing and electrocatalysis.
Collapse
|
6
|
Zhang Y, Chu C, Xu Y, Ma Z, Han H. Bimetallic catalyst derived from copper cobalt carbonate hydroxides mediated ZIF-67 composite for efficient hydrogenation of 4-nitrophenol. Colloids Surf A Physicochem Eng Asp 2022. [DOI: 10.1016/j.colsurfa.2022.128477] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
7
|
Perovskite Nanoparticles as an Electrochemical Sensing Platform for Detection of Warfarin. BIOSENSORS 2022; 12:bios12020092. [PMID: 35200352 PMCID: PMC8869580 DOI: 10.3390/bios12020092] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Revised: 01/28/2022] [Accepted: 01/31/2022] [Indexed: 11/17/2022]
Abstract
Chemically prepared PrAlO3 perovskite nanoparticles (NPs) were applied for the electrochemical detection of warfarin, which is commonly utilized for preventing blood clots, such as in deep vein thrombosis. PrAlO3 perovskite NPs were synthesized by the co-precipitation process at environmental conditions. Crystallographic structure, phase purity, morphological structure, thermal stability, optical properties, and electrochemical characteristics were investigated by X-ray diffraction (XRD), transmission electron microscopy (TEM), thermogravimetric analysis (TGA), Fourier transform infrared (FTIR) spectroscopy, UV-visible analysis, and cyclic voltammetry techniques. TEM micrographs showed the highly crystalline structure, smooth surface, irregular shape, and size of nanocrystalline particles with an average size of 20–30 nm. Particularly crystalline perovskite NPs were pasted on glassy carbon electrodes (GCE) to electrochemically detect the warfarin contents in liquid samples. The fabricated electrode was electrochemically characterized by different parameters such as different potential, scan rates, same potential with seven consecutive cycles, time response, real-time sample analysis, and as a function of warfarin concentration in phosphate buffer solution (0.1 M PBS, pH 7.2). The electrochemical electrode was further verified with various potentials of 5, 10, 20, 50, 100, and 150 mV/s, which exhibited sequential enhancements in the potential range. For detecting warfarin over a wide concentration range (19.5 µM–5000 µM), the detection devices offered good sensitivity and a low limit of detection (19.5 µM). The time-dependent influence was examined using chronoamperometry (perovskite NPs/GCE) in the absence and presence of warfarin at four distinct voltages of +0.05 to +1.2 V from 0 to 1000 s. The repeatability and reliability of the constructed electrochemical sensing electrode were also evaluated in terms of cyclic response for 30 days, demonstrating that it is substantially more reliable for a longer period. The fabricated perovskite NPs/GCE electrodes could be employed for the rapid identification of other drugs.
Collapse
|
8
|
Current progress in organic–inorganic hetero-nano-interfaces based electrochemical biosensors for healthcare monitoring. Coord Chem Rev 2022. [DOI: 10.1016/j.ccr.2021.214282] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
9
|
Dar RA, Naikoo GA, Srivastava AK, Hassan IU, Karna SP, Giri L, Shaikh AMH, Rezakazemi M, Ahmed W. Performance of graphene-zinc oxide nanocomposite coated-glassy carbon electrode in the sensitive determination of para-nitrophenol. Sci Rep 2022; 12:117. [PMID: 34996919 PMCID: PMC8741969 DOI: 10.1038/s41598-021-03495-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2021] [Accepted: 11/25/2021] [Indexed: 12/28/2022] Open
Abstract
Graphene: zinc oxide nanocomposite (GN:ZnO NC) platform was tried for the sensitive determination of para-nitrophenol (p-NP) through the electrochemical method. ZnO nanoparticles (NPs) were synthesized by the modified wet-chemical method where in potassium hydroxide and zinc nitrate were used as precursors and starch as a stabilizing agent. A green and facile approach was applied to synthesize GN:ZnO NC in which glucose was employed as a reductant to reduce graphene-oxide to graphene in the presence of ZnO NPs. The synthesized NC was characterized using scanning and high-resolution transmission electron microscopy, energy dispersive x-ray analysis, X-ray diffraction and Raman spectroscopic techniques to examine the crystal phase, crystallinity, morphology, chemical composition and phase structure. GN:ZnO NC layer deposited over the glassy carbon electrode (GCE) was initially probed for its electrochemical performance using the standard 1 mM K3[Fe(CN)6] model complex. GN:ZnO NC modified GCE was monitored based on p-NP concentration. An enhanced current response was observed in 0.1 M phosphate buffer of pH 6.8 for the determination of p-NP in a linear working range of 0.09 × 10-6 to 21.80 × 10-6 M with a lower detection limit of 8.8 × 10-9 M employing square wave adsorptive stripping voltammetric technique at a deposition-potential and deposition-time of - 1.0 V and 300 s, respectively. This electrochemical sensor displayed very high specificity for p-NP with no observed interference from some other possible interfering substances such as 2, 4-di-NP, ortho-NP, and meta-NP. The developed strategy was useful for sensitive detection of p-NP quantity in canals/rivers and ground H2O samples with good recoveries.
Collapse
Affiliation(s)
- Riyaz Ahmad Dar
- Department of Chemistry, Maharashtra College of Arts, Science and Commerce, Mumbai, 400008, India.
| | - Gowhar Ahmad Naikoo
- Department of Mathematics and Sciences, College of Arts and Applied Sciences, Dhofar University, PC 211, Salalah, Sultanate of Oman.
| | - Ashwini Kumar Srivastava
- Department of Chemistry, University of Mumbai, Vidyanagari, Santacruz (East), Mumbai, 400098, India
| | - Israr Ul Hassan
- College of Engineering, Dhofar University, PC 211, Salalah, Sultanate of Oman
| | - Shashi P Karna
- US Army Research Laboratory, Weapons and Materials Research Laboratory, FCDD-RLW-, Aberdeen Proving Ground, Maryland, 21005-5069, USA
| | - Lily Giri
- US Army Research Laboratory, Weapons and Materials Research Laboratory, FCDD-RLW-, Aberdeen Proving Ground, Maryland, 21005-5069, USA
| | - Ahamad M H Shaikh
- Department of Chemistry, Maharashtra College of Arts, Science and Commerce, Mumbai, 400008, India
| | - Mashallah Rezakazemi
- Faculty of Chemical and Materials Engineering, Shahrood University of Technology, Shahrood, Iran
| | - Waqar Ahmed
- School of Mathematics and Physics, College of Science, University of Lincoln, Lincoln, LN6 7TS, UK
| |
Collapse
|
10
|
Lei L, Li C, Huang W, Wu K. Simultaneous detection of 4-chlorophenol and 4-nitrophenol using a Ti 3C 2T x MXene based electrochemical sensor. Analyst 2021; 146:7593-7600. [PMID: 34780586 DOI: 10.1039/d1an01799c] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Developing a sensitive and rapid detection method for 4-chlorophenol (4-CP) and 4-nitrophenol (4-NP) is very important due to their high toxicity. In this work, bulk Ti3AlC2 powder was etched to Ti3C2Tx for the first time through a hydrothermal reaction in NaF/HCl solution. After ultrasonication in N-methylpyrrolidone (NMP), Ti3C2Tx powder was successfully exfoliated into multilayered Ti3C2Tx nanosheets (i.e. Ti3C2Tx MXene). The prepared Ti3C2Tx MXene not only has a large electrochemical surface area for the oxidation of 4-CP and 4-NP, but also lowers their electron transfer resistance. As a result, the oxidation signals of 4-CP and 4-NP are significantly improved on the surface of the Ti3C2Tx MXene. Based on the remarkable signal amplification of the Ti3C2Tx MXene, a sensitive and rapid method was developed for the simultaneous detection of 4-CP and 4-NP. The linear range is from 0.1 to 20.0 μM for 4-CP, and from 0.5 to 25.0 μM for 4-NP, with detection limits of 0.062 μM (4-CP) and 0.11 μM (4-NP). This method was used in wastewater samples, and the accuracy was confirmed to be good by high-performance liquid chromatography.
Collapse
Affiliation(s)
- Ling Lei
- Hubei Key Laboratory of Bioinorganic Chemistry and Materia Medica, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan 430074, China.
| | - Caoling Li
- Hubei Key Laboratory of Bioinorganic Chemistry and Materia Medica, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan 430074, China.
| | - Wensheng Huang
- Hubei Key Laboratory of Biological Resources Protection and Utilization, School of Chemistry and Environmental Engineering, Hubei University for Nationalities, Enshi 445000, China.
| | - Kangbing Wu
- Hubei Key Laboratory of Bioinorganic Chemistry and Materia Medica, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan 430074, China.
| |
Collapse
|
11
|
Chen D, Zhang Y, Mao P, Jiang X, Li J, Sun A, Shen J. Carbon black supported on a Mn-MIL-100 framework as high-efficiency electrocatalysts for nitrophenol reduction. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115824] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
12
|
Luminescent lanthanide nanocomposites in thermometry: Chemistry of dopant ions and host matrices. Coord Chem Rev 2021. [DOI: 10.1016/j.ccr.2021.214040] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
13
|
Ansari AA, Parchur AK, Thorat ND, Chen G. New advances in pre-clinical diagnostic imaging perspectives of functionalized upconversion nanoparticle-based nanomedicine. Coord Chem Rev 2021. [DOI: 10.1016/j.ccr.2021.213971] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|