1
|
Galappaththige S, Pathmanathan P, Gray RA. A computational modeling framework for pre-clinical evaluation of cardiac mapping systems. Front Physiol 2023; 14:1074527. [PMID: 37485068 PMCID: PMC10358980 DOI: 10.3389/fphys.2023.1074527] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Accepted: 05/31/2023] [Indexed: 07/25/2023] Open
Abstract
There are a variety of difficulties in evaluating clinical cardiac mapping systems, most notably the inability to record the transmembrane potential throughout the entire heart during patient procedures which prevents the comparison to a relevant "gold standard". Cardiac mapping systems are comprised of hardware and software elements including sophisticated mathematical algorithms, both of which continue to undergo rapid innovation. The purpose of this study is to develop a computational modeling framework to evaluate the performance of cardiac mapping systems. The framework enables rigorous evaluation of a mapping system's ability to localize and characterize (i.e., focal or reentrant) arrhythmogenic sources in the heart. The main component of our tool is a library of computer simulations of various dynamic patterns throughout the entire heart in which the type and location of the arrhythmogenic sources are known. Our framework allows for performance evaluation for various electrode configurations, heart geometries, arrhythmias, and electrogram noise levels and involves blind comparison of mapping systems against a "silver standard" comprised of computer simulations in which the precise transmembrane potential patterns throughout the heart are known. A feasibility study was performed using simulations of patterns in the human left atria and three hypothetical virtual catheter electrode arrays. Activation times (AcT) and patterns (AcP) were computed for three virtual electrode arrays: two basket arrays with good and poor contact and one high-resolution grid with uniform spacing. The average root mean squared difference of AcTs of electrograms and those of the nearest endocardial action potential was less than 1 ms and therefore appears to be a poor performance metric. In an effort to standardize performance evaluation of mapping systems a novel performance metric is introduced based on the number of AcPs identified correctly and those considered spurious as well as misclassifications of arrhythmia type; spatial and temporal localization accuracy of correctly identified patterns was also quantified. This approach provides a rigorous quantitative analysis of cardiac mapping system performance. Proof of concept of this computational evaluation framework suggests that it could help safeguard that mapping systems perform as expected as well as provide estimates of system accuracy.
Collapse
|
2
|
Atrial fibrosis identification with unipolar electrogram eigenvalue distribution analysis in multi-electrode arrays. Med Biol Eng Comput 2022; 60:3091-3112. [PMID: 36098928 PMCID: PMC9537244 DOI: 10.1007/s11517-022-02648-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Accepted: 08/09/2022] [Indexed: 12/01/2022]
Abstract
Abstract Atrial fibrosis plays a key role in the initiation and progression of atrial fibrillation (AF). Atrial fibrosis is typically identified by a peak-to-peak amplitude of bipolar electrograms (b-EGMs) lower than 0.5 mV, which may be considered as ablation targets. Nevertheless, this approach disregards signal spatiotemporal information and b-EGM sensitivity to catheter orientation. To overcome these limitations, we propose the dominant-to-remaining eigenvalue dominance ratio (EIGDR) of unipolar electrograms (u-EGMs) within neighbor electrode cliques as a waveform dispersion measure, hypothesizing that it is correlated with the presence of fibrosis. A simulated 2D tissue with a fibrosis patch was used for validation. We computed EIGDR maps from both original and time-aligned u-EGMs, denoted as \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$\mathcal {R}$$\end{document}R and \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$\mathcal{R}^{\mathcal{A}}$$\end{document}RA, respectively, also mapping the gain in eigenvalue concentration obtained by the alignment, \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$\Delta \mathcal{R}^{\mathcal{A}}$$\end{document}ΔRA. The performance of each map in detecting fibrosis was evaluated in scenarios including noise and variable electrode-tissue distance. Best results were achieved by \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$\mathcal{R}^{\mathcal{A}}$$\end{document}RA, reaching 94% detection accuracy, versus the 86% of b-EGMs voltage maps. The proposed strategy was also tested in real u-EGMs from fibrotic and non-fibrotic areas over 3D electroanatomical maps, supporting the ability of the EIGDRs as fibrosis markers, encouraging further studies to confirm their translation to clinical settings. Graphical Abstract Upper panels: map of \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$\mathcal {R}^{\mathcal {A}}$$\end{document}RA from 3×3 cliques for Ψ= 0∘ and bipolar voltage map Vb-m, performed assuming a variable electrode-to-tissue distance and noisy u-EGMs (noise level σv = 46.4 μV ). Lower panels: detected fibrotic areas (brown), using the thresholds that maximize detection accuracy of each map ![]()
Collapse
|
3
|
Bartolucci C, Fabbri C, Tomasi C, Sabbatani P, Severi S, Corsi C. Computational Analysis of Mapping Catheter Geometry and Contact Quality Effects on Rotor Detection in Atrial Fibrillation. Front Physiol 2021; 12:732161. [PMID: 34955872 PMCID: PMC8696082 DOI: 10.3389/fphys.2021.732161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Accepted: 11/18/2021] [Indexed: 11/30/2022] Open
Abstract
Atrial fibrillation (AF) is the most common cardiac arrhythmia and catheter mapping has been proved to be an effective approach for detecting AF drivers to be targeted by ablation. Among drivers, the so-called rotors have gained the most attention: their identification and spatial location could help to understand which patient-specific mechanisms are acting, and thus to guide the ablation execution. Since rotor detection by multi-electrode catheters may be influenced by several structural parameters including inter-electrode spacing, catheter coverage, and endocardium-catheter distance, in this study we proposed a tool for testing the ability of different catheter shapes to detect rotors in different conditions. An approach based on the solution of the monodomain equations coupled with a modified Courtemanche ionic atrial model, that considers an electrical remodeling, was applied to simulate spiral wave dynamics on a 2D model for 7.75 s. The developed framework allowed the acquisition of unipolar signals at 2 KHz. Two high-density multipolar catheters were simulated (Advisor™ HD Grid and PentaRay®) and placed in a 2D region in which the simulated spiral wave persists longer. The configuration of the catheters was then modified by changing the number of electrodes, inter-electrodes distance, position, and atrial-wall distance for assessing how they would affect the rotor detection. In contact with the wall and at 1 mm distance from it, all the configurations detected the rotor correctly, irrespective of geometry, coverage, and inter-electrode distance. In the HDGrid-like geometry, the increase of the inter-electrode distance from 3 to 6 mm caused rotor detection failure at 2 mm distance from the LA wall. In the PentaRay-like configuration, regardless of inter-electrode distance, rotor detection failed at 3 mm endocardium-catheter distance. The asymmetry of this catheter resulted in rotation-dependent rotor detection. To conclude, the computational framework we developed is based on realistic catheter shapes designed with parameter configurations which resemble clinical settings. Results showed it is well suited to investigate how mapping catheter geometry and location affect AF driver detection, therefore it is a reliable tool to design and test new mapping catheters.
Collapse
Affiliation(s)
- Chiara Bartolucci
- Computational Physiopathology Unit, Department of Electrical, Electronic and Information Engineering "Guglielmo Marconi", University of Bologna, Bologna, Italy
| | - Claudio Fabbri
- Computational Physiopathology Unit, Department of Electrical, Electronic and Information Engineering "Guglielmo Marconi", University of Bologna, Bologna, Italy
| | - Corrado Tomasi
- Electrophysiology Laboratory, Cardiology Unit, Ravenna and Cesena Hospitals, Azienda Unità Sanitaria Locale della Romagna, Ravenna, Italy
| | - Paolo Sabbatani
- Electrophysiology Laboratory, Cardiology Unit, Ravenna and Cesena Hospitals, Azienda Unità Sanitaria Locale della Romagna, Ravenna, Italy
| | - Stefano Severi
- Computational Physiopathology Unit, Department of Electrical, Electronic and Information Engineering "Guglielmo Marconi", University of Bologna, Bologna, Italy
| | - Cristiana Corsi
- Computational Physiopathology Unit, Department of Electrical, Electronic and Information Engineering "Guglielmo Marconi", University of Bologna, Bologna, Italy
| |
Collapse
|
4
|
Salvador-Montañés Ó, Ramirez RJ, Takemoto Y, Ennis SR, Garcia-Iglesias D, Wang S, Wolfer PJ, Jiang J, Mironov SV, Pandit SV, Jalife J, Berenfeld O. Panoramic Endocardial Optical Mapping Demonstrates Serial Rotors Acceleration and Increasing Complexity of Activity During Onset of Cholinergic Atrial Fibrillation. J Am Heart Assoc 2021; 10:e022300. [PMID: 34726079 PMCID: PMC8751940 DOI: 10.1161/jaha.121.022300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background Activation during onset of atrial fibrillation is poorly understood. We aimed at developing a panoramic optical mapping system for the atria and test the hypothesis that sequential rotors underlie acceleration of atrial fibrillation during onset. Methods and Results Five sheep hearts were Langendorff perfused in the presence of 0.25 µmol/L carbachol. Novel optical system recorded activations simultaneously from the entire left and right atrial endocardial surfaces. Twenty sustained (>40 s) atrial fibrillation episodes were induced by a train and premature stimuli protocol. Movies obtained immediately (Initiation stage) and 30 s (Early Stabilization stage) after premature stimulus were analyzed. Serial rotor formation was observed in all sustained inductions and none in nonsustained inductions. In sustained episodes maximal dominant frequency increased from (mean±SD) 11.5±1.74 Hz during Initiation to 14.79±1.30 Hz at Early Stabilization (P<0.0001) and stabilized thereafter. At rotor sites, mean cycle length (CL) during 10 prerotor activations increased every cycle by 0.53% (P=0.0303) during Initiation and 0.34% (P=0.0003) during Early Stabilization. In contrast, CLs at rotor sites showed abrupt decreases after the rotors appearances by a mean of 9.65% (P<0.0001) during both stages. At Initiation, atria‐wide accelerations and decelerations during rotors showed a net acceleration result whereby post‐rotors atria‐wide minimal CL (CLmin) were 95.5±6.8% of the prerotor CLmin (P=0.0042). In contrast, during Early Stabilization, there was no net acceleration in CLmin during accelerating rotors (prerotor=84.9±11.0% versus postrotor=85.8±10.8% of Initiation, P=0.4029). Levels of rotor drift distance and velocity correlated with atria‐wide acceleration. Nonrotor phase singularity points did not accelerate atria‐wide activation but multiplied during Initiation until Early Stabilization. Increasing number of singularity points, indicating increased complexity, correlated with atria‐wide CLmin reduction (P<0.0001). Conclusions Novel panoramic optical mapping of the atria demonstrates shortening CL at rotor sites during cholinergic atrial fibrillation onset. Atrial fibrillation acceleration toward Early Stabilization correlates with the net result of atria‐wide accelerations during drifting rotors activity.
Collapse
Affiliation(s)
- Óscar Salvador-Montañés
- Center for Arrhythmia Research Department of Internal Medicine - Cardiology University of Michigan Ann Arbor MI.,Facultad de Medicina Universidad Francisco de Vitoria, Pozuelo de Alarcon Mardid Spain.,Hospital Universitario de Torrejón Mardid Spain
| | - Rafael J Ramirez
- Center for Arrhythmia Research Department of Internal Medicine - Cardiology University of Michigan Ann Arbor MI.,The Department of Physiology and Biophysics Virginia Commonwealth University Richmond VA
| | - Yoshio Takemoto
- Center for Arrhythmia Research Department of Internal Medicine - Cardiology University of Michigan Ann Arbor MI.,Cardiovascular Medicine Gifu Prefectural Tajimi Hospital Tajimi Japan
| | - Steven R Ennis
- Center for Arrhythmia Research Department of Internal Medicine - Cardiology University of Michigan Ann Arbor MI
| | - Daniel Garcia-Iglesias
- Center for Arrhythmia Research Department of Internal Medicine - Cardiology University of Michigan Ann Arbor MI.,Hospital Universitario Central de Asturias Oviedo Spain
| | - Sicong Wang
- Center for Arrhythmia Research Department of Internal Medicine - Cardiology University of Michigan Ann Arbor MI.,Institute for Stem Cell Biology and Regenerative Medicine Stanford University Palo Alto CA
| | - Patrick J Wolfer
- Center for Arrhythmia Research Department of Internal Medicine - Cardiology University of Michigan Ann Arbor MI.,Michigan Technological University Houghton MI
| | - Jiang Jiang
- Center for Arrhythmia Research Department of Internal Medicine - Cardiology University of Michigan Ann Arbor MI
| | - Sergey V Mironov
- Center for Arrhythmia Research Department of Internal Medicine - Cardiology University of Michigan Ann Arbor MI
| | - Sandeep V Pandit
- Center for Arrhythmia Research Department of Internal Medicine - Cardiology University of Michigan Ann Arbor MI
| | - José Jalife
- Center for Arrhythmia Research Department of Internal Medicine - Cardiology University of Michigan Ann Arbor MI.,Centro Nacional de Investigaciones Cardiovasculares Carlos III Madrid Spain
| | - Omer Berenfeld
- Center for Arrhythmia Research Department of Internal Medicine - Cardiology University of Michigan Ann Arbor MI
| |
Collapse
|
5
|
Riccio J, Alcaine A, Rocher S, Martinez-Mateu L, Laranjo S, Saiz J, Laguna P, Martínez JP. Characterization of Atrial Propagation Patterns and Fibrotic Substrate With a Modified Omnipolar Electrogram Strategy in Multi-Electrode Arrays. Front Physiol 2021; 12:674223. [PMID: 34539424 PMCID: PMC8446360 DOI: 10.3389/fphys.2021.674223] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Accepted: 07/13/2021] [Indexed: 11/15/2022] Open
Abstract
Introduction: The omnipolar electrogram method was recently proposed to try to generate orientation-independent electrograms. It estimates the electric field from the bipolar electrograms of a clique, under the assumption of locally plane and homogeneous propagation. The local electric field evolution over time describes a loop trajectory from which omnipolar signals in the propagation direction, substrate and propagation features, are derived. In this work, we propose substrate and conduction velocity mapping modalities based on a modified version of the omnipolar electrogram method, which aims to reduce orientation-dependent residual components in the standard approach. Methods: A simulated electrical propagation in 2D, with a tissue including a circular patch of diffuse fibrosis, was used for validation. Unipolar electrograms were calculated in a multi-electrode array, also deriving bipolar electrograms along the two main directions of the grid. Simulated bipolar electrograms were also contaminated with real noise, to assess the robustness of the mapping strategies against noise. The performance of the maps in identifying fibrosis and in reproducing unipolar reference voltage maps was evaluated. Bipolar voltage maps were also considered for performance comparison. Results: Results show that the modified omnipolar mapping strategies are more accurate and robust against noise than bipolar and standard omnipolar maps in fibrosis detection (accuracies higher than 85 vs. 80% and 70%, respectively). They present better correlation with unipolar reference voltage maps than bipolar and original omnipolar maps (Pearson's correlations higher than 0.75 vs. 0.60 and 0.70, respectively). Conclusion: The modified omnipolar method improves fibrosis detection, characterization of substrate and propagation, also reducing the residual sensitivity to directionality over the standard approach and improving robustness against noise. Nevertheless, studies with real electrograms will elucidate its impact in catheter ablation interventions.
Collapse
Affiliation(s)
- Jennifer Riccio
- Biomedical Signal Interpretation and Computational Simulation Group, Aragón Institute of Engineering Research, IIS Aragón, Universidad de Zaragoza, Zaragoza, Spain
| | - Alejandro Alcaine
- Biomedical Signal Interpretation and Computational Simulation Group, Aragón Institute of Engineering Research, IIS Aragón, Universidad de Zaragoza, Zaragoza, Spain
- Facultad de Ciencias de la Salud, Universidad San Jorge, Zaragoza, Spain
- Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, Zaragoza, Spain
| | - Sara Rocher
- Centro de Investigación e Innovación en Ingeniería, Universitat Politècnica de València, Valencia, Spain
| | - Laura Martinez-Mateu
- Departamento de Teoría de la Señal y Comunicaciones y Sistemas Telemáticos y Computación, Universidad Rey Juan Carlos, Madrid, Spain
| | - Sergio Laranjo
- Department of Pediatric Cardiology, Hospital Santa Marta, Centro Hospitalar de Lisboa Central, Lisbon, Portugal
| | - Javier Saiz
- Centro de Investigación e Innovación en Ingeniería, Universitat Politècnica de València, Valencia, Spain
| | - Pablo Laguna
- Biomedical Signal Interpretation and Computational Simulation Group, Aragón Institute of Engineering Research, IIS Aragón, Universidad de Zaragoza, Zaragoza, Spain
- Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, Zaragoza, Spain
| | - Juan Pablo Martínez
- Biomedical Signal Interpretation and Computational Simulation Group, Aragón Institute of Engineering Research, IIS Aragón, Universidad de Zaragoza, Zaragoza, Spain
- Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, Zaragoza, Spain
| |
Collapse
|
6
|
Van Nieuwenhuyse E, Martinez-Mateu L, Saiz J, Panfilov AV, Vandersickel N. Directed graph mapping exceeds phase mapping in discriminating true and false rotors detected with a basket catheter in a complex in-silico excitation pattern. Comput Biol Med 2021; 133:104381. [PMID: 33901713 PMCID: PMC8204274 DOI: 10.1016/j.compbiomed.2021.104381] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Revised: 04/02/2021] [Accepted: 04/02/2021] [Indexed: 12/04/2022]
Abstract
Atrial fibrillation (AF) is the most frequently encountered arrhythmia in clinical practise. One of the major problems in the management of AF is the difficulty in identifying the arrhythmia sources from clinical recordings. That difficulty occurs because it is currently impossible to verify algorithms which determine these sources in clinical data, as high resolution true excitation patterns cannot be recorded in patients. Therefore, alternative approaches, like computer modelling are of great interest. In a recent published study such an approach was applied for the verification of one of the most commonly used algorithms, phase mapping (PM). A meandering rotor was simulated in the right atrium and a basket catheter was placed at 3 different locations: at the Superior Vena Cava (SVC), the Crista Terminalis (CT) and at the Coronary Sinus (CS). It was shown that although PM can identify the true source, it also finds several false sources due to the far-field effects and interpolation errors in all three positions. In addition, the detection efficiency strongly depended on the basket location. Recently, a novel tool was developed to analyse any arrhythmia called Directed Graph Mapping (DGM). DGM is based on network theory and creates a directed graph of the excitation pattern, from which the location and the source of the arrhythmia can be detected. Therefore, the objective of the current study was to compare the efficiency of DGM with PM on the basket dataset of this meandering rotor. The DGM-tool was applied for a wide variety of conduction velocities (minimal and maximal), which are input parameters of DGM. Overall we found that DGM was able to distinguish between the true rotor and false rotors for both the SVC and CT basket positions. For example, for the SVC position with a CVmin=0.01cmms, DGM detected the true core with a prevalence of 82% versus 94% for PM. Three false rotors where detected for 39.16% (DGM) versus 100% (PM); 22.64% (DGM) versus 100% (PM); and 0% (DGM) versus 57% (PM). Increasing CVmin to 0.02cmms had a stronger effect on the false rotors than on the true rotor. This led to a detection rate of 56.6% for the true rotor, while all the other false rotors disappeared. A similar trend was observed for the CT position. For the CS position, DGM already had a low performance for the true rotor for CVmin=0.01cmms (14.7%). For CVmin=0.02cmms the false and the true rotors could therefore not be distinguished. We can conclude that DGM can overcome some of the limitations of PM by varying one of its input parameters (CVmin). The true rotor is less dependent on this parameter than the false rotors, which disappear at a CVmin=0.02cmms. In order to increase to detection rate of the true rotor, one can decrease CVmin and discard the new rotors which also appear at lower values of CVmin.
Collapse
Affiliation(s)
| | - Laura Martinez-Mateu
- Departamento de Teoría de La Señal y Las Comunicaciones y Sistemas Telemáticos y Computación, Universidad Rey Juan Carlos, Madrid, Spain
| | - Javier Saiz
- Centro de Investigación e Innovación en Bioingeniería, Universitat Politècnica de València, Valencia, Spain
| | - Alexander V Panfilov
- Department of Physics and Astronomy, Ghent University, Ghent, Belgium; Ural Federal University, Ekaterinburg, Russia; World-Class Research Center "Digital Biodesign and Personalized Healthcare", Sechenov University, Moscow, Russia
| | - Nele Vandersickel
- Department of Physics and Astronomy, Ghent University, Ghent, Belgium
| |
Collapse
|
7
|
Belletti R, Romero L, Martinez-Mateu L, Cherry EM, Fenton FH, Saiz J. Arrhythmogenic Effects of Genetic Mutations Affecting Potassium Channels in Human Atrial Fibrillation: A Simulation Study. Front Physiol 2021; 12:681943. [PMID: 34135774 PMCID: PMC8201780 DOI: 10.3389/fphys.2021.681943] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Accepted: 05/05/2021] [Indexed: 11/16/2022] Open
Abstract
Genetic mutations in genes encoding for potassium channel protein structures have been recently associated with episodes of atrial fibrillation in asymptomatic patients. The aim of this study is to investigate the potential arrhythmogenicity of three gain-of-function mutations related to atrial fibrillation-namely, KCNH2 T895M, KCNH2 T436M, and KCNE3-V17M-using modeling and simulation of the electrophysiological activity of the heart. A genetic algorithm was used to tune the parameters' value of the original ionic currents to reproduce the alterations experimentally observed caused by the mutations. The effects on action potentials, ionic currents, and restitution properties were analyzed using versions of the Courtemanche human atrial myocyte model in different tissues: pulmonary vein, right, and left atrium. Atrial susceptibility of the tissues to spiral wave generation was also investigated studying the temporal vulnerability. The presence of the three mutations resulted in an overall more arrhythmogenic substrate. Higher current density, action potential duration shortening, and flattening of the restitution curves were the major effects of the three mutations at the single-cell level. The genetic mutations at the tissue level induced a higher temporal vulnerability to the rotor's initiation and progression, by sustaining spiral waves that perpetuate until the end of the simulation. The mutation with the highest pro-arrhythmic effects, exhibiting the widest sustained VW and the smallest meandering rotor's tip areas, was KCNE3-V17M. Moreover, the increased susceptibility to arrhythmias and rotor's stability was tissue-dependent. Pulmonary vein tissues were more prone to rotor's initiation, while in left atrium tissues rotors were more easily sustained. Re-entries were also progressively more stable in pulmonary vein tissue, followed by the left atrium, and finally the right atrium. The presence of the genetic mutations increased the susceptibility to arrhythmias by promoting the rotor's initiation and maintenance. The study provides useful insights into the mechanisms underlying fibrillatory events caused by KCNH2 T895M, KCNH2 T436M, and KCNE3-V17M and might aid the planning of patient-specific targeted therapies.
Collapse
Affiliation(s)
- Rebecca Belletti
- Centro de Investigación e Innovación en Bioingeniería, Universitat Politècnica de València, Valencia, Spain
| | - Lucia Romero
- Centro de Investigación e Innovación en Bioingeniería, Universitat Politècnica de València, Valencia, Spain
| | - Laura Martinez-Mateu
- Departamento de Teoría de la Señal y Comunicaciones y Sistemas Telemáticos y Computación, Universidad Rey Juan Carlos, Madrid, Spain
| | - Elizabeth M. Cherry
- School of Computational Science and Engineering, Georgia Institute of Technology, Atlanta, GA, United States
| | - Flavio H. Fenton
- School of Physics, Georgia Institute of Technology, Atlanta, GA, United States
| | - Javier Saiz
- Centro de Investigación e Innovación en Bioingeniería, Universitat Politècnica de València, Valencia, Spain
| |
Collapse
|
8
|
Rodrigo M, Waddell K, Magee S, Rogers AJ, Alhusseini M, Hernandez-Romero I, Costoya-Sánchez A, Liberos A, Narayan SM. Non-invasive Spatial Mapping of Frequencies in Atrial Fibrillation: Correlation With Contact Mapping. Front Physiol 2021; 11:611266. [PMID: 33584334 PMCID: PMC7873897 DOI: 10.3389/fphys.2020.611266] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Accepted: 12/04/2020] [Indexed: 11/13/2022] Open
Abstract
Introduction: Regional differences in activation rates may contribute to the electrical substrates that maintain atrial fibrillation (AF), and estimating them non-invasively may help guide ablation or select anti-arrhythmic medications. We tested whether non-invasive assessment of regional AF rate accurately represents intracardiac recordings. Methods: In 47 patients with AF (27 persistent, age 63 ± 13 years) we performed 57-lead non-invasive Electrocardiographic Imaging (ECGI) in AF, simultaneously with 64-pole intracardiac signals of both atria. ECGI was reconstructed by Tikhonov regularization. We constructed personalized 3D AF rate distribution maps by Dominant Frequency (DF) analysis from intracardiac and non-invasive recordings. Results: Raw intracardiac and non-invasive DF differed substantially, by 0.54 Hz [0.13 – 1.37] across bi-atrial regions (R2 = 0.11). Filtering by high spectral organization reduced this difference to 0.10 Hz (cycle length difference of 1 – 11 ms) [0.03 – 0.42] for patient-level comparisons (R2 = 0.62), and 0.19 Hz [0.03 – 0.59] and 0.20 Hz [0.04 – 0.61] for median and highest DF, respectively. Non-invasive and highest DF predicted acute ablation success (p = 0.04). Conclusion: Non-invasive estimation of atrial activation rates is feasible and, when filtered by high spectral organization, provide a moderate estimate of intracardiac recording rates in AF. Non-invasive technology could be an effective tool to identify patients who may respond to AF ablation for personalized therapy.
Collapse
Affiliation(s)
- Miguel Rodrigo
- Stanford University School of Medicine, Stanford, CA, United States.,ITACA Institute, Universitat Politècnica de València, Valencia, Spain
| | - Kian Waddell
- Stanford University School of Medicine, Stanford, CA, United States
| | - Sarah Magee
- Stanford University School of Medicine, Stanford, CA, United States
| | - Albert J Rogers
- Stanford University School of Medicine, Stanford, CA, United States
| | | | | | | | - Alejandro Liberos
- ITACA Institute, Universitat Politècnica de València, Valencia, Spain
| | - Sanjiv M Narayan
- Stanford University School of Medicine, Stanford, CA, United States
| |
Collapse
|
9
|
Abstract
Determining optimal treatment strategies for complex arrhythmogenesis in AF is confounded by the lack of consensus regarding the mechanisms causing AF. Studies report different mechanisms for AF, ranging from hierarchical drivers to anarchical multiple activation wavelets. Differences in the assessment of AF mechanisms are likely due to AF being recorded across diverse models using different investigational tools, spatial scales and clinical populations. The authors review different AF mechanisms, including anatomical and functional re-entry, hierarchical drivers and anarchical multiple wavelets. They then describe different cardiac mapping techniques and analysis tools, including activation mapping, phase mapping and fibrosis identification. They explain and review different data challenges, including differences between recording devices in spatial and temporal resolutions, spatial coverage and recording surface, and report clinical outcomes using different data modalities. They suggest future research directions for investigating the mechanisms underlying human AF.
Collapse
Affiliation(s)
- Caroline H Roney
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.,Imperial Centre for Cardiac Engineering, Imperial College London, London, UK
| | - Andrew L Wit
- Imperial Centre for Cardiac Engineering, Imperial College London, London, UK.,Department of Pharmacology, Columbia University College of Physicians and Surgeons, New York, NY, US
| | - Nicholas S Peters
- Imperial Centre for Cardiac Engineering, Imperial College London, London, UK.,National Heart and Lung Institute, Imperial College London, London, UK
| |
Collapse
|