1
|
Ashraf G, Aziz A, Iftikhar T, Zhong ZT, Asif M, Chen W. The Roadmap of Graphene-Based Sensors: Electrochemical Methods for Bioanalytical Applications. BIOSENSORS 2022; 12:1183. [PMID: 36551150 PMCID: PMC9775289 DOI: 10.3390/bios12121183] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Revised: 12/07/2022] [Accepted: 12/16/2022] [Indexed: 06/17/2023]
Abstract
Graphene (GR) has engrossed immense research attention as an emerging carbon material owing to its enthralling electrochemical (EC) and physical properties. Herein, we debate the role of GR-based nanomaterials (NMs) in refining EC sensing performance toward bioanalytes detection. Following the introduction, we briefly discuss the GR fabrication, properties, application as electrode materials, the principle of EC sensing system, and the importance of bioanalytes detection in early disease diagnosis. Along with the brief description of GR-derivatives, simulation, and doping, classification of GR-based EC sensors such as cancer biomarkers, neurotransmitters, DNA sensors, immunosensors, and various other bioanalytes detection is provided. The working mechanism of topical GR-based EC sensors, advantages, and real-time analysis of these along with details of analytical merit of figures for EC sensors are discussed. Last, we have concluded the review by providing some suggestions to overcome the existing downsides of GR-based sensors and future outlook. The advancement of electrochemistry, nanotechnology, and point-of-care (POC) devices could offer the next generation of precise, sensitive, and reliable EC sensors.
Collapse
Affiliation(s)
- Ghazala Ashraf
- Britton Chance Center for Biomedical Photonics at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Ayesha Aziz
- Britton Chance Center for Biomedical Photonics at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Tayyaba Iftikhar
- Key Laboratory of Material Chemistry for Energy Conversion and Storage, Ministry of Education, Hubei Key Laboratory of Material Chemistry and Service Failure, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Zi-Tao Zhong
- Britton Chance Center for Biomedical Photonics at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Muhammad Asif
- Hubei Key Laboratory of Plasma Chemistry and Advanced Materials, School of Materials Science and Engineering, Wuhan Institute of Technology, Wuhan 430205, China
| | - Wei Chen
- Britton Chance Center for Biomedical Photonics at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| |
Collapse
|
2
|
Ashraf G, Ahmad T, Ahmed MZ, Murtaza, Rasimi Y. Advances in Metal-Organic Framework (MOFs) based biosensors for diagnosis: An update. Curr Top Med Chem 2022; 22:CTMC-EPUB-125974. [PMID: 36043769 DOI: 10.2174/1568026622666220829125548] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Revised: 06/02/2022] [Accepted: 06/29/2022] [Indexed: 11/22/2022]
Abstract
Metal-organic frameworks (MOFs) have significant advantages over other candidate classes of chemo-sensory materials owing to their extraordinary structural tunability and characteristics. MOF-based biosensing is a simple, and convenient method for identifying various species. Biomarkers are molecular or cellular processes that link environmental exposure to a health outcome. Biomarkers are important in understanding the links between environmental chemical exposure and the development of chronic diseases, as well as in identifying disease-prone subgroups. Until now, several species, including nanoparticles (NPs) and their nanocomposites, small molecules, and unique complex systems, have been used for the chemical sensing of biomarkers. Following the overview of the field, we discussed the various fabrication methods for MOFs development in this review. We provide a thorough overview of the previous five years of progress to broaden the scope of analytes for future research. Several enzymatic and non-enzymatic sensors are offered, together with a mandatory measuring method that includes detection range and dynamic range. In addition, we reviewed the comparison of enzymatic and non-enzymatic biosensors, inventive edges, and the difficulties that need to be solved. This work might open up new possibilities for material production, sensor development, medical diagnostics, and other sensing fields.
Collapse
Affiliation(s)
- Ghazala Ashraf
- Britton Chance Center for Biomedical Photonics at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan Hubei, P. R. China
| | - Tauqir Ahmad
- Chemistry Department, King Fahd University of Petroleum and Minerals, Dhahran, Saudi Arabia
| | | | - Murtaza
- Department of Chemical Sciences, University of Lakki Marwat, Khyber Pakhtunkhwa, Pakistan
| | - Yousef Rasimi
- Cellular and Molecular Research Center, Urmia University of Medical Sciences, Urmia, Iran
- Department of Biochemistry, School of Medicine, Urmia University of Medical Sciences, Urmia, Iran
| |
Collapse
|
3
|
Zhang J, Yang L, Pei J, Tian Y, Liu J. A reagentless electrochemical immunosensor for sensitive detection of carcinoembryonic antigen based on the interface with redox probe-modified electron transfer wires and effectively immobilized antibody. Front Chem 2022; 10:939736. [PMID: 36003618 PMCID: PMC9393226 DOI: 10.3389/fchem.2022.939736] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Accepted: 06/27/2022] [Indexed: 12/13/2022] Open
Abstract
Convenient and sensitive detection of tumors marked in serum samples is of great significance for the early diagnosis of cancers. Facile fabrication of reagentless electrochemical immunosensor with efficient sensing interface and high sensitivity is still a challenge. Herein, an electrochemical immunosensor was easily fabricated based on the easy fabrication of immunoassay interface with electron transfer wires, confined redox probes, and conveniently immobilized antibodies, which can achieve sensitive and reagentless determination of the tumor marker, carcinoembryonic antigen (CEA). Carboxyl multi-walled carbon nanotubes (MWCNTs) were firstly modified with an electrochemical redox probe, methylene blue (MB), which has redox potentials distinguished from those of redox molecules commonly existing in biological samples (for example, ascorbic acid and uric acid). After the as-prepared MB-modified MWCNT (MWCNT-MB) was coated on the supporting glassy carbon electrode (GCE), the MWCNT-MB/GCE exhibited improved active area and electron transfer property. Polydopamine (PDA) was then in situ synthesized through simple self-polymerization of dopamine, which acts as the bio-linker to covalently immobilize the anti-CEA antibody (Ab). The developed immunosensor could be applied for electrochemical detection of CEA based on the decrease in the redox signal of MB after specific binding of CEA and immobilized Ab. The fabricated immunosensor can achieve sensitive determination of CEA ranging from 10 pg/ml to 100 ng/ml with a limit of detection (LOD) of 0.6 pg/ml. Determination of CEA in human serum samples was also realized with high accuracy.
Collapse
Affiliation(s)
- Jing Zhang
- Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Third Hospital of Shanxi Medical University, Taiyuan, China
- Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Luoxing Yang
- Key Laboratory of Surface & Interface Science of Polymer Materials of Zhejiang Province, Department of Chemistry, Zhejiang Sci-Tech University, Hangzhou, China
| | - Jie Pei
- Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Third Hospital of Shanxi Medical University, Taiyuan, China
- Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Yanzhang Tian
- Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Third Hospital of Shanxi Medical University, Taiyuan, China
- Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
- *Correspondence: Yanzhang Tian, ; Jiyang Liu,
| | - Jiyang Liu
- Key Laboratory of Surface & Interface Science of Polymer Materials of Zhejiang Province, Department of Chemistry, Zhejiang Sci-Tech University, Hangzhou, China
- *Correspondence: Yanzhang Tian, ; Jiyang Liu,
| |
Collapse
|
4
|
Kuang Z, Luginsland J, Thomas RJ, Dennis PB, Kelley-Loughnane N, Roach WP, Naik RR. Molecular dynamics simulations explore effects of electric field orientations on spike proteins of SARS-CoV-2 virions. Sci Rep 2022; 12:12986. [PMID: 35906467 PMCID: PMC9334739 DOI: 10.1038/s41598-022-17009-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2021] [Accepted: 07/19/2022] [Indexed: 11/21/2022] Open
Abstract
Emergence of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and its current worldwide spread have caused a pandemic of acute respiratory disease COVID-19. The virus can result in mild to severe, and even to fatal respiratory illness in humans, threatening human health and public safety. The spike (S) protein on the surface of viral membrane is responsible for viral entry into host cells. The discovery of methods to inactivate the entry of SARS-CoV-2 through disruption of the S protein binding to its cognate receptor on the host cell is an active research area. To explore other prevention strategies against the quick spread of the virus and its mutants, non-equilibrium molecular dynamics simulations have been employed to explore the possibility of manipulating the structure–activity of the SARS-CoV-2 spike glycoprotein by applying electric fields (EFs) in both the protein axial directions and in the direction perpendicular to the protein axis. We have found out the application of EFs perpendicular to the protein axis is most effective in denaturing the HR2 domain which plays critical role in viral-host membrane fusion. This finding suggests that varying irradiation angles may be an important consideration in developing EF based non-invasive technologies to inactivate the virus.
Collapse
Affiliation(s)
- Zhifeng Kuang
- Materials and Manufacturing Directorate, Air Force Research Laboratory, WPAFB, Dayton, OH, 45433, USA.
| | - John Luginsland
- Work Performed With Confluent Sciences, LLC, Albuquerque, NM, 87111, USA
| | - Robert J Thomas
- 711th Human Performance Wing, Air Force Research Laboratory, JBSA Fort Sam Houston, San Antonio, TX, 78234, USA
| | - Patrick B Dennis
- Materials and Manufacturing Directorate, Air Force Research Laboratory, WPAFB, Dayton, OH, 45433, USA
| | - Nancy Kelley-Loughnane
- Materials and Manufacturing Directorate, Air Force Research Laboratory, WPAFB, Dayton, OH, 45433, USA
| | - William P Roach
- Air Force Office of Scientific Research, Arlington, VA, 22203, USA
| | - Rajesh R Naik
- 711Th Human Performance Wing, Air Force Research Laboratory, WPAFB, Dayton, OH, 45433, USA.
| |
Collapse
|
5
|
A Review on Potential Electrochemical Point-of-Care Tests Targeting Pandemic Infectious Disease Detection: COVID-19 as a Reference. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10070269] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Fast and accurate point-of-care testing (POCT) of infectious diseases is crucial for diminishing the pandemic miseries. To fight the pandemic coronavirus disease 2019 (COVID-19), numerous interesting electrochemical point-of-care (POC) tests have been evolved to rapidly identify the causal organism SARS-CoV-2 virus, its nucleic acid and antigens, and antibodies of the patients. Many of those electrochemical biosensors are impressive in terms of miniaturization, mass production, ease of use, and speed of test, and they could be recommended for future applications in pandemic-like circumstances. On the other hand, self-diagnosis, sensitivity, specificity, surface chemistry, electrochemical components, device configuration, portability, small analyzers, and other features of the tests can yet be improved. Therefore, this report reviews the developmental trend of electrochemical POC tests (i.e., test platforms and features) reported for the rapid diagnosis of COVID-19 and correlates any significant advancements with relevant references. POCTs incorporating microfluidic/plastic chips, paper devices, nanomaterial-aided platforms, smartphone integration, self-diagnosis, and epidemiological reporting attributes are also surfed to help with future pandemic preparedness. This review especially screens the low-cost and easily affordable setups so that management of pandemic disease becomes faster and easier. Overall, the review is a wide-ranging package for finding appropriate strategies of electrochemical POCT targeting pandemic infectious disease detection.
Collapse
|
6
|
Hamidi-Asl E, Heidari-Khoshkelat L, Bakhsh Raoof J, Richard TP, Farhad S, Ghani M. A review on the recent achievements on coronaviruses recognition using electrochemical detection methods. Microchem J 2022; 178:107322. [PMID: 35233118 PMCID: PMC8875855 DOI: 10.1016/j.microc.2022.107322] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Revised: 02/21/2022] [Accepted: 02/22/2022] [Indexed: 12/14/2022]
Abstract
Various coronaviruses, which cause a wide range of human and animal diseases, have emerged in the past 50 years. This may be due to their abilities to recombine, mutate, and infect multiple species and cell types. A novel coronavirus, which is a family of severe acute respiratory syndrome (SARS) and Middle East respiratory syndrome (MERS), has been termed COVID-19 by the World Health Organization (WHO). COVID-19 is the strain that has not been previously identified in humans. The early identification and diagnosis of the virus is crucial for effective pandemic prevention. In this study, we review shortly various diagnostic methods for virus assay and focus on recent advances in electrochemical biosensors for COVID-19 detection.
Collapse
Affiliation(s)
- Ezat Hamidi-Asl
- Advanced Energy & Manufacturing Lab, Department of Mechanical Engineering, University of Akron, Akron, OH 44325, USA
| | - Leyla Heidari-Khoshkelat
- Eletroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran
| | - Jahan Bakhsh Raoof
- Eletroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran
| | - Tara P Richard
- Department of Biological Science, Southeastern Louisiana University, Hammond, LA 70402, USA
| | - Siamak Farhad
- Advanced Energy & Manufacturing Lab, Department of Mechanical Engineering, University of Akron, Akron, OH 44325, USA
| | - Milad Ghani
- Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran
| |
Collapse
|
7
|
Zambry NS, Obande GA, Khalid MF, Bustami Y, Hamzah HH, Awang MS, Aziah I, Manaf AA. Utilizing Electrochemical-Based Sensing Approaches for the Detection of SARS-CoV-2 in Clinical Samples: A Review. BIOSENSORS 2022; 12:473. [PMID: 35884276 PMCID: PMC9312918 DOI: 10.3390/bios12070473] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/22/2022] [Revised: 06/20/2022] [Accepted: 06/21/2022] [Indexed: 05/16/2023]
Abstract
The development of precise and efficient diagnostic tools enables early treatment and proper isolation of infected individuals, hence limiting the spread of coronavirus disease 2019 (COVID-19). The standard diagnostic tests used by healthcare workers to diagnose severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infection have some limitations, including longer detection time, the need for qualified individuals, and the use of sophisticated bench-top equipment, which limit their use for rapid SARS-CoV-2 assessment. Advances in sensor technology have renewed the interest in electrochemical biosensors miniaturization, which provide improved diagnostic qualities such as rapid response, simplicity of operation, portability, and readiness for on-site screening of infection. This review gives a condensed overview of the current electrochemical sensing platform strategies for SARS-CoV-2 detection in clinical samples. The fundamentals of fabricating electrochemical biosensors, such as the chosen electrode materials, electrochemical transducing techniques, and sensitive biorecognition molecules, are thoroughly discussed in this paper. Furthermore, we summarised electrochemical biosensors detection strategies and their analytical performance on diverse clinical samples, including saliva, blood, and nasopharyngeal swab. Finally, we address the employment of miniaturized electrochemical biosensors integrated with microfluidic technology in viral electrochemical biosensors, emphasizing its potential for on-site diagnostics applications.
Collapse
Affiliation(s)
- Nor Syafirah Zambry
- Institute for Research in Molecular Medicine (INFORMM), Health Campus, Universiti Sains Malaysia, Kubang Kerian 16150, Kelantan, Malaysia; (N.S.Z.); (M.F.K.)
| | - Godwin Attah Obande
- Department of Medical Microbiology and Parasitology, Universiti Sains Malaysia, Kubang Kerian 16150, Kelantan, Malaysia;
- Department of Microbiology, Faculty of Science, Federal University of Lafia, Lafia PMB 146, Nasarawa State, Nigeria
| | - Muhammad Fazli Khalid
- Institute for Research in Molecular Medicine (INFORMM), Health Campus, Universiti Sains Malaysia, Kubang Kerian 16150, Kelantan, Malaysia; (N.S.Z.); (M.F.K.)
| | - Yazmin Bustami
- School of Biological Sciences, Universiti Sains Malaysia, Gelugor 11800, Pulau Pinang, Malaysia;
| | - Hairul Hisham Hamzah
- School of Chemical Sciences, Universiti Sains Malaysia, Gelugor 11800, Pulau Pinang, Malaysia;
| | - Mohd Syafiq Awang
- Collaborative Microelectronic Design Excellence Centre (CEDEC), Sains@USM, Universiti Sains Malaysia, Bayan Lepas 11900, Pulau Pinang, Malaysia;
| | - Ismail Aziah
- Institute for Research in Molecular Medicine (INFORMM), Health Campus, Universiti Sains Malaysia, Kubang Kerian 16150, Kelantan, Malaysia; (N.S.Z.); (M.F.K.)
| | - Asrulnizam Abd Manaf
- Collaborative Microelectronic Design Excellence Centre (CEDEC), Sains@USM, Universiti Sains Malaysia, Bayan Lepas 11900, Pulau Pinang, Malaysia;
| |
Collapse
|
8
|
Ashraf G, Zhong ZT, Asif M, Aziz A, Song L, Zhang S, Liu B, Chen W, Zhao YD. Extension of duplex specific nuclease sensing application with RNA aptamer. Talanta 2022; 242:123314. [PMID: 35182839 DOI: 10.1016/j.talanta.2022.123314] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Revised: 02/08/2022] [Accepted: 02/10/2022] [Indexed: 02/09/2023]
Abstract
Duplex specific nuclease (DSN) that can precisely cleave DNA portion in double-stranded DNA or DNA-RNA hybrid has engrossed immense attention owing to its great potential in emerging bioanalytical applications. Here, we present a novel approach to extend DSN sensing application by coupling RNA aptamer. Specially designed RNA ligand sequences are used to capture the target and simultaneously provide complementary sequences of DNA for DSN aided fluorescent signal enhancement. A clotting enzyme, thrombin, has been used as a model analyte. One RNA aptamer combined with the target molecule can generate fluorescent signals through cleavage of hybridized TaqMan DNA probe (P2) by DSN. The proposed assay has achieved the lowest detection limit of 0.039 pM. The assay has been applied for real-time detection of thrombin release from live cells and other biotic media for early disease diagnosis. The developed method is versatile and can detect various other targets by choosing the relevant aptamer and probe sequences. This method is promising to be applied to medical diagnosis, biosensing, food safety, environmental monitoring, and other fields.
Collapse
Affiliation(s)
- Ghazala Ashraf
- Britton Chance Center for Biomedical Photonics at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, Hubei, PR China
| | - Zi-Tao Zhong
- Britton Chance Center for Biomedical Photonics at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, Hubei, PR China
| | - Muhammad Asif
- Hubei Key Laboratory of Plasma Chemistry and Advanced Materials, School of Materials Science and Engineering, Wuhan Institute of Technology, Wuhan, 430205, PR China
| | - Ayesha Aziz
- Britton Chance Center for Biomedical Photonics at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, Hubei, PR China
| | - Laibo Song
- Britton Chance Center for Biomedical Photonics at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, Hubei, PR China
| | - Shujie Zhang
- Britton Chance Center for Biomedical Photonics at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, Hubei, PR China
| | - Bo Liu
- Britton Chance Center for Biomedical Photonics at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, Hubei, PR China
| | - Wei Chen
- Britton Chance Center for Biomedical Photonics at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, Hubei, PR China.
| | - Yuan-Di Zhao
- Britton Chance Center for Biomedical Photonics at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, Hubei, PR China; Key Laboratory of Biomedical Photonics (HUST), Ministry of Education, Huazhong University of Science and Technology, Wuhan, 430074, Hubei, PR China.
| |
Collapse
|
9
|
Asif M, Aziz A, Ashraf G, Iftikhar T, Sun Y, Liu H. Turning the Page: Advancing Detection Platforms for Sulfate Reducing Bacteria and their Perks. CHEM REC 2021; 22:e202100166. [PMID: 34415677 DOI: 10.1002/tcr.202100166] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2021] [Revised: 08/05/2021] [Indexed: 12/27/2022]
Abstract
Sulfate reducing bacteria (SRB) are blamed as main culprits in triggering huge corrosion damages by microbiologically influenced corrosion. They obtained their energy through enzymatic conversion of sulfates to sulfides which are highly corrosive. However, conventional SRB detection methods are complex, time-consuming and are not enough sensitive for reliable detection. The advanced biosensing technologies capable of overcoming the aforementioned drawbacks are in demand. So, nanomaterials being economical, environmental friendly and showing good electrocatalytic properties are promising candidates for electrochemical detection of SRB as compared with antibody based assays. Here, we summarize the recent advances in the detection of SRB using different techniques such as PCR, UV visible method, fluorometric method, immunosensors, electrochemical sensors and photoelectrochemical sensors. We also discuss the SRB detection based on determination of sulfide, typical metabolic product of SRB.
Collapse
Affiliation(s)
- Muhammad Asif
- Hubei key Laboratory of Plasma Chemistry and Advanced Materials, School of Materials Science and Engineering, Wuhan Institute of Technology, Wuhan, 430205, China.,Key Laboratory of Material Chemistry for Energy Conversion and Storage, Ministry of Education, Hubei Key Laboratory of Material Chemistry and Service Failure, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan, 430074, P. R. China
| | - Ayesha Aziz
- Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, PR China
| | - Ghazala Ashraf
- Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, PR China
| | - Tayyaba Iftikhar
- Key Laboratory of Material Chemistry for Energy Conversion and Storage, Ministry of Education, Hubei Key Laboratory of Material Chemistry and Service Failure, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan, 430074, P. R. China
| | - Yimin Sun
- Hubei key Laboratory of Plasma Chemistry and Advanced Materials, School of Materials Science and Engineering, Wuhan Institute of Technology, Wuhan, 430205, China
| | - Hongfang Liu
- Key Laboratory of Material Chemistry for Energy Conversion and Storage, Ministry of Education, Hubei Key Laboratory of Material Chemistry and Service Failure, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan, 430074, P. R. China
| |
Collapse
|
10
|
Shaffaf T, Forouhi S, Ghafar-Zadeh E. Towards Fully Integrated Portable Sensing Devices for COVID-19 and Future Global Hazards: Recent Advances, Challenges, and Prospects. MICROMACHINES 2021; 12:915. [PMID: 34442537 PMCID: PMC8401608 DOI: 10.3390/mi12080915] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/01/2021] [Revised: 07/25/2021] [Accepted: 07/28/2021] [Indexed: 01/08/2023]
Abstract
Since the onset of the coronavirus disease 2019 (COVID-19) pandemic, this fatal disease has been the leading cause of the death of more than 3.9 million people around the world. This tragedy taught us that we should be well-prepared to control the spread of such infectious diseases and prevent future hazards. As a consequence, this pandemic has drawn the attention of many researchers to the development of portable platforms with short hands-on and turnaround time suitable for batch production in urgent pandemic situations such as that of COVID-19. Two main groups of diagnostic assays have been reported for the detection of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) including nucleic acid-based and protein-based assays. The main focus of this paper is on the latter, which requires a shorter time duration, less skilled technicians, and faces lower contamination. Furthermore, this paper gives an overview of the complementary metal-oxide-semiconductor (CMOS) biosensors, which are potentially useful for implementing point-of-care (PoC) platforms based on such assays. CMOS technology, as a predominant technology for the fabrication of integrated circuits, is a promising candidate for the development of PoC devices by offering the advantages of reliability, accessibility, scalability, low power consumption, and distinct cost.
Collapse
Affiliation(s)
- Tina Shaffaf
- Biologically Inspired Sensors and Actuators Laboratory (BioSA), York University, Toronto, ON M3J 1P3, Canada; (T.S.); (S.F.)
- Department of Biology, Faculty of Science, York University, Toronto, ON M3J 1P3, Canada
| | - Saghi Forouhi
- Biologically Inspired Sensors and Actuators Laboratory (BioSA), York University, Toronto, ON M3J 1P3, Canada; (T.S.); (S.F.)
- Department of Electrical Engineering and Computer Science, Lassonde School of Engineering, York University, Toronto, ON M3J 1P3, Canada
| | - Ebrahim Ghafar-Zadeh
- Biologically Inspired Sensors and Actuators Laboratory (BioSA), York University, Toronto, ON M3J 1P3, Canada; (T.S.); (S.F.)
- Department of Biology, Faculty of Science, York University, Toronto, ON M3J 1P3, Canada
- Department of Electrical Engineering and Computer Science, Lassonde School of Engineering, York University, Toronto, ON M3J 1P3, Canada
| |
Collapse
|
11
|
Mutharani B, Ranganathan P, Tsai HC, Lai JY. Synthesis of hierarchically porous 3D polymeric carbon superstructures with nitrogen-doping by self-transformation: a robust electrocatalyst for the detection of herbicide bentazone. Mikrochim Acta 2021; 188:271. [PMID: 34302235 DOI: 10.1007/s00604-021-04910-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2021] [Accepted: 06/21/2021] [Indexed: 11/25/2022]
Abstract
Bentazone (BEZ) is one of the utmost selective problematic contact-past herbicide with high toxicity for humans owing to feasible contamination of surface and ground water. In this work, an electrochemical sensor has been developed for the sensitive detection of BEZ, based on hierarchically porous three-dimensional (3D) carbon superstructures (CS)-modified electrodes. The CSs (namely, CSHEX, CSPY, CSACN, and CSNOS) were prepared by the pyrolysis process from organic porous polyacrylonitrile (PAN) superstructure particles (namely, PANHEX, PANPY, PANACN, and PANNOS) obtained by free radical polymerization method using different solvents (hexane, pyridine, acetonitrile, and also no solvent). The assembly with the working electrode of CSs causes the electrocatalytic BEZ oxidation by rapid electron transfer compared to the PAN superstructures and bare electrodes. Intriguingly, compared to all electrodes, CSHEX-modified electrode showed the superior electrochemical detection of BEZ at a working potential of 0.99 V (vs. Ag/AgCl), very low detection limit (0.002 μM), wide dynamic linear range (0.03 to 200 μM), high sensitivity (9.95 μA μM-1 cm-2), and excellent reliability. The advanced sensors displayed an intensification of oxidation peak current of BEZ with high selectivity, remarkable sensitivity, and reproducibility for BEZ detection and received satisfactory outcomes designating the application of sensors for the determination of BEZ in river water samples.
Collapse
Affiliation(s)
- Bhuvanenthiran Mutharani
- Graduate Institute of Applied Science and Technology, National Taiwan University of Science and Technology, Taipei, Taiwan.,Advanced Membrane Materials Center, National Taiwan University of Science and Technology, Taipei, Taiwan
| | - Palraj Ranganathan
- Institute of Organic and Polymeric Materials, National Taipei University of Technology, No. 1, Section 3, Chung-Hsiao East Road, Taipei, 106, Taiwan, Republic of China
| | - Hsieh-Chih Tsai
- Graduate Institute of Applied Science and Technology, National Taiwan University of Science and Technology, Taipei, Taiwan. .,Advanced Membrane Materials Center, National Taiwan University of Science and Technology, Taipei, Taiwan. .,R & D Center for Membrane Technology, Chung Yuan Christian University, Chungli, Taoyuan, Taiwan.
| | - Juin-Yih Lai
- Graduate Institute of Applied Science and Technology, National Taiwan University of Science and Technology, Taipei, Taiwan.,Advanced Membrane Materials Center, National Taiwan University of Science and Technology, Taipei, Taiwan.,R & D Center for Membrane Technology, Chung Yuan Christian University, Chungli, Taoyuan, Taiwan
| |
Collapse
|