1
|
Boopathi E, Den RB, Thangavel C. Innate Immune System in the Context of Radiation Therapy for Cancer. Cancers (Basel) 2023; 15:3972. [PMID: 37568788 PMCID: PMC10417569 DOI: 10.3390/cancers15153972] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 07/24/2023] [Accepted: 07/27/2023] [Indexed: 08/13/2023] Open
Abstract
Radiation therapy (RT) remains an integral component of modern oncology care, with most cancer patients receiving radiation as a part of their treatment plan. The main goal of ionizing RT is to control the local tumor burden by inducing DNA damage and apoptosis within the tumor cells. The advancement in RT, including intensity-modulated RT (IMRT), stereotactic body RT (SBRT), image-guided RT, and proton therapy, have increased the efficacy of RT, equipping clinicians with techniques to ensure precise and safe administration of radiation doses to tumor cells. In this review, we present the technological advancement in various types of RT methods and highlight their clinical utility and associated limitations. This review provides insights into how RT modulates innate immune signaling and the key players involved in modulating innate immune responses, which have not been well documented earlier. Apoptosis of cancer cells following RT triggers immune systems that contribute to the eradication of tumors through innate and adoptive immunity. The innate immune system consists of various cell types, including macrophages, dendritic cells, and natural killer cells, which serve as key mediators of innate immunity in response to RT. This review will concentrate on the significance of the innate myeloid and lymphoid lineages in anti-tumorigenic processes triggered by RT. Furthermore, we will explore essential strategies to enhance RT efficacy. This review can serve as a platform for researchers to comprehend the clinical application and limitations of various RT methods and provides insights into how RT modulates innate immune signaling.
Collapse
Affiliation(s)
- Ettickan Boopathi
- Center for Translational Medicine, Department of Medicine, Thomas Jefferson University, Philadelphia, PA 19107, USA
| | - Robert B. Den
- Department of Radiation Oncology, Sidney Kimmel Cancer Center, Thomas Jefferson University, Philadelphia, PA 19107, USA;
| | - Chellappagounder Thangavel
- Center for Translational Medicine, Department of Medicine, Thomas Jefferson University, Philadelphia, PA 19107, USA
- Department of Radiation Oncology, Sidney Kimmel Cancer Center, Thomas Jefferson University, Philadelphia, PA 19107, USA;
| |
Collapse
|
2
|
Xue J, Jin S, Zhang H, Zou K, Sheng J, Tang J, Zhao W, Yang P, Tang L, Lv X, Lv L. A simplified non-coplanar volumetric modulated arc therapy for the whole brain radiotherapy with hippocampus avoidance. Front Oncol 2023; 13:1143564. [PMID: 37152035 PMCID: PMC10155751 DOI: 10.3389/fonc.2023.1143564] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Accepted: 03/24/2023] [Indexed: 05/09/2023] Open
Abstract
Purpose To evaluate the feasibility of using a simplified non-coplanar volumetric modulated arc therapy (NC-VMAT) and investigate its dosimetric advantages compared with intensity modulated radiation therapy (IMRT) and coplanar volumetric modulated arc therapy (C-VMAT) for hippocampal-avoidance whole brain radiation therapy (HA-WBRT). Methods Ten patients with brain metastase (BM) were included for HA-WBRT. Three treatment plans were generated for each case using IMRT, C-VMAT, and NC-VMAT, respectively. Results The dosimetric results of the three techniques complied roughly with the RTOG 0933 criteria. After dose normalization, the V30Gy of whole brain planned target volume (WB-PTV) in all the plans was controlled at 95%. Homogeneity index (HI) of WB-PTV was significantly reduced in NC-VMAT (0.249 ± 0.017) over IMRT (0.265 ± 0.020, p=0.005) and C-VMAT (0.261 ± 0.014, p=0.020). In terms of conformity index (CI), NC-VMAT could provide a value of 0.821 ± 0.010, which was significantly superior to IMRT (0.788 ± 0.019, p<0.001). According to D2% of WB-PTV, NC-VMAT could provide a value of 35.62 ± 0.37Gy, significantly superior to IMRT (36.43 ± 0.65Gy, p<0.001). According to D50% of WB-PTV, NC-VMAT can achieve the lowest value of 33.18 ± 0.29Gy, significantly different from IMRT (33.47 ± 0.43, p=0.034) and C-VMAT (33.58 ± 0.37, p=0.006). Regarding D2%, D98%, and Dmean of hippocampus, NC-VMAT could control them at 15.57 ± 0.18Gy, 8.37 ± 0.26Gy and 11.71 ± 0.48Gy, respectively. D2% and Dmean of hippocampus for NC-VMAT was significantly lower than IMRT (D2%: 16.07 ± 0.29Gy, p=0.001 Dmean: 12.18 ± 0.33Gy, p<0.001) and C-VMAT (D2%: 15.92 ± 0.37Gy, p=0.009 Dmean: 12.21 ± 0.54Gy, p<0.001). For other organs-at-risk (OARs), according to D2% of the right optic nerves and the right lenses, NC-VMAT had the lowest values of 31.86 ± 1.11Gy and 7.15 ± 0.31Gy, respectively, which were statistically different from the other two techniques. For other organs including eyes and optic chiasm, NC-VMAT could achieve the lowest doses, different from IMRT statistically. Conclusion The dosimetry of the three techniques for HA-WBRT could roughly comply with the proposals from RTOG 0933. After dose normalization (D95%=30Gy), NC-VMAT could significantly improve dose homogeneity and reduce the D50% in the brain. Besides, it can reduce the D2% of the hippocampus, optic nerves, and lens. With this approach, an efficient and straightforward plan was accomplished.
Collapse
Affiliation(s)
- Juan Xue
- The Department of Radiation Oncology, First Affiliated Hospital, Dalian Medical University, Dalian, Liaoning, China
| | - Sunian Jin
- The Department of Radiation Oncology, First Affiliated Hospital, Dalian Medical University, Dalian, Liaoning, China
| | - Hongtao Zhang
- The Department of Radiation Oncology, First Affiliated Hospital, Dalian Medical University, Dalian, Liaoning, China
| | - Kun Zou
- The Department of Radiation Oncology, First Affiliated Hospital, Dalian Medical University, Dalian, Liaoning, China
| | - Junxiu Sheng
- The Department of Radiation Oncology, First Affiliated Hospital, Dalian Medical University, Dalian, Liaoning, China
| | - Jinhai Tang
- The Department of Radiation Oncology, First Affiliated Hospital, Dalian Medical University, Dalian, Liaoning, China
| | - Wanying Zhao
- The Department of Radiation Oncology, First Affiliated Hospital, Dalian Medical University, Dalian, Liaoning, China
| | - Ping Yang
- The Department of Radiation Oncology, First Affiliated Hospital, Dalian Medical University, Dalian, Liaoning, China
| | - Lufan Tang
- The Department of Radiation Oncology, First Affiliated Hospital, Dalian Medical University, Dalian, Liaoning, China
| | - Xiupeng Lv
- The Department of Radiation Oncology, First Affiliated Hospital, Dalian Medical University, Dalian, Liaoning, China
- *Correspondence: Xiupeng Lv, ; Li Lv,
| | - Li Lv
- The Department of Pathology, Second Affiliated Hospital, Dalian Medical University, Dalian, Liaoning, China
- *Correspondence: Xiupeng Lv, ; Li Lv,
| |
Collapse
|
3
|
Kim H, Jung J, Jung H, Jeong J, Lee D, Jeong HW, Lee Y. Comparison of Jaw Mode and Field Width for Left-Breast Cancer Using TomoDirect Three-Dimensional Conformal Radiation Therapy: A Phantom Study. Healthcare (Basel) 2022; 10:healthcare10122431. [PMID: 36553955 PMCID: PMC9777817 DOI: 10.3390/healthcare10122431] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Revised: 11/24/2022] [Accepted: 11/30/2022] [Indexed: 12/03/2022] Open
Abstract
It is very important to use effective parameters in the treatment plan of breast cancer patients in TomoDirect (TD)-three-dimensional conformal radiation therapy (TD-3DCRT). The objective of this study was to compare the radiation treatment plans to the parameters (jaw width and jaw mode) of TD-3DCRT for left-breast cancer. This study was conducted using the phantom, the jaw mode (fixed and dynamic) and field width (2.5 cm and 5.0 cm) were controlled to compare the TD-3DCRT treatment plans. There was small difference in the conformity index (CI) and homogeneity index (HI) values for target according to the jaw mode for each field width. As a result of observation in terms of dose, treatment time and unnecessary damage to surrounding normal organs could be minimized when dynamic jaw with a field width of 5.0 cm was used. In conclusion, we verified that the use of dynamic jaws and 5.0 cm field width was effective in left-breast cancer radiotherapy plan using TD-3DCRT.
Collapse
Affiliation(s)
- Haneul Kim
- Department of Radiological Science, College of Health Science, Gachon University, 191, Hambakmoero, Yeonsu-gu, Incheon 21936, Republic of Korea
| | - Jaehong Jung
- Department of Radiation Oncology, College of Medicine, Soonchunhyang University Bucheon Hospital, 170, Jomaruro, Bucheon-si 14584, Republic of Korea
| | - Hyunseo Jung
- Department of Radiological Science, College of Health Science, Gachon University, 191, Hambakmoero, Yeonsu-gu, Incheon 21936, Republic of Korea
| | - Jibeom Jeong
- Department of Radiological Science, College of Health Science, Gachon University, 191, Hambakmoero, Yeonsu-gu, Incheon 21936, Republic of Korea
| | - Dohwa Lee
- Department of Radiological Science, College of Health Science, Gachon University, 191, Hambakmoero, Yeonsu-gu, Incheon 21936, Republic of Korea
| | - Hyun-Woo Jeong
- Department of Biomedical Engineering, Eulji University, 553, Sanseong-daero, Sujeong-gu, Seongnam-si 13135, Republic of Korea
- Correspondence: (H.-W.J.); (Y.L.); Tel.: +82-31-740-7135 (H.-W.J.); +82-32-820-4362 (Y.L.)
| | - Youngjin Lee
- Department of Radiological Science, College of Health Science, Gachon University, 191, Hambakmoero, Yeonsu-gu, Incheon 21936, Republic of Korea
- Correspondence: (H.-W.J.); (Y.L.); Tel.: +82-31-740-7135 (H.-W.J.); +82-32-820-4362 (Y.L.)
| |
Collapse
|
4
|
Bartlett GK, Njeh CF, Huang KC, DesRosiers C, Guo G. VMAT partial arc technique decreases dose to organs at risk in whole pelvic radiotherapy for prostate cancer when compared to full arc VMAT and IMRT. Med Dosim 2022; 48:8-15. [PMID: 36319515 DOI: 10.1016/j.meddos.2022.09.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2022] [Accepted: 09/16/2022] [Indexed: 11/05/2022]
Abstract
Whole pelvic radiotherapy (WPRT) can sterilize microscopic lymph node metastases in treatment of prostate cancer. WPRT, compared to prostate only radiotherapy (PORT), is associated with increased acute gastrointestinal, and hematological toxicities. To further explore minimizing normal tissue toxicities associated with WPRT in definitive IMRT for prostate cancer, this planning study compared dosimetric differences between static 9-field-IMRT, full arc VMAT, and mixed partial-full arc VMAT techniques. In this retrospective study, 12 prostate cancer patients who met the criteria for WPRT were randomly selected for this study. The initial volume, PTV46, included the prostate, seminal vesicles, and pelvic nodes with margin and was prescribed to 4600 cGy. The cone-down volume, PTV78, included the prostate and proximal seminal vesicles with margin to a total dose of 7800 cGy. For each CT image set, 3 plans were generated for each of the PTVs: an IMRT plan, a full arc (FA) VMAT plan, and a mixed partial-full arc (PFA) VMAT plan, using 6MV photons energy. According to RTOG protocols none of the plans had a major Conformity Index (CI) violation by any of the 3 planning techniques. PFA plan had the best mean CI index of 1.00 and significantly better than IMRT (p = 0.03) and FA (p = 0.007). For equivalent PTV coverage, the average composite gradient index of the PFA plans was better than the IMRT and the FA plans with values 1.92, 2.03, and 2.01 respectively. The defference was statistically significant between PFA/IMRT and PFA/FA, with p- values of < 0.001. The IMRT plans and the PFA plans provided very similar doses to the rectum, bladder, sigmoid colon, and femoral heads, which were lower than the dose in the FA plans. There was a significant decrease in the mean dose to the rectum from 4524 cGy with the FA to 4182 cGy with the PFA and 4091 cGy with IMRT (p < 0.001). The percent of rectum receiving 4000 cGy was also the highest with FA at 66.1% compared to 49.9% (PFA) and 47.5% (IMRT). There was a significant decrease in the mean dose to the bladder from 3922 cGy (FA) to 3551 cGy (PFA) and 3612 cGy (IMRT) (p < 0.001). The percent of bladder receiving 4000 cGy was also the highest with FA at 45.4% compared to 36.6% (PFA) and 37.4% (IMRT). The average mean dose to the sigmoid colon decreased from 4177 cGy (FA) to 3893 cGy (PFA) and 3819 cGy (IMRT). The average mean dose to the femoral heads decreased from 2091 cGy (FA) to 2026 cGy (PFA) and 1987 cGy (IMRT). Considering the improvement in plan quality indices recorded in this study including the dose gradient and the dose to organs at risk, mixed partial-full arc plans may be the preferred VMAT treatment technique over full arc plans for prostate cancer treatments that include nodal volumes.
Collapse
Affiliation(s)
- Gregory K Bartlett
- Radiation Oncology Department, Indiana University, 535 Barnhill Drive, Indianapolis, IN, 45202
| | - Christopher F Njeh
- Radiation Oncology Department, Indiana University, 535 Barnhill Drive, Indianapolis, IN, 45202.
| | - Ke C Huang
- Radiation Oncology Department, Indiana University, 535 Barnhill Drive, Indianapolis, IN, 45202
| | - Colleen DesRosiers
- Radiation Oncology Department, Indiana University, 535 Barnhill Drive, Indianapolis, IN, 45202
| | - Gordon Guo
- Radiation Oncology Department, Indiana University, 535 Barnhill Drive, Indianapolis, IN, 45202
| |
Collapse
|
5
|
Zhang R, Xie Y, DiTusa C, Ohler R, Heins D, Bourgeois D, Guo B. Flattening Filter-Free Volumetric-Modulated Arc Radiotherapy for Left-Sided Whole-Breast, Partial-Breast, and Postmastectomy Irradiations. J Med Phys 2022; 47:166-172. [PMID: 36212208 PMCID: PMC9542989 DOI: 10.4103/jmp.jmp_146_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Revised: 03/23/2022] [Accepted: 04/09/2022] [Indexed: 11/20/2022] Open
Abstract
Purpose: Unflattened photon beams exhibit many benefits over traditional flattened beams for radiotherapy (RT), but comprehensive evaluations of dosimetric results and beam-on time using flattening filter-free (FFF) beams for all types of breast irradiations are still lacking. The purpose of this study was to investigate if FFF RT can maintain equal or better dose coverage than standard flattened-beam RT while reducing doses to organs at risk (OARs) and beam-on time for various types of breast cancer irradiations. Methods and Materials: FFF volumetric-modulated arc therapy (FFF-VMAT) and standard VMAT (STD-VMAT) treatment plans were created for 15 whole-breast irradiation (WBI) patients with 50 Gy/25 fractions, 13 partial-breast irradiation (PBI) patients with 38.5 Gy/10 fractions, and 9 postmastectomy irradiation (PMI) patients with 50 Gy/25 fractions. Planning target volume (PTV) coverage and dose to OARs were evaluated. Results: Both techniques produced clinically acceptable plans for all three types of irradiations. For WBI, FFF-VMAT plans exhibited similar PTV and OARs evaluation metrics as STD-VMAT. For PBI, FFF-VMAT plans showed significantly lower mean and maximum doses for ipsilateral and contralateral lungs, contralateral breast, and heart. For PMI, FFF-VMAT plans showed significantly lower mean dose and V5 for contralateral breast but significantly higher Dmean, Dmax, and V20 for ipsilateral lung and significantly higher Dmean, V22.5, and V30 for heart. FFF-VMAT techniques significantly reduced beam-on time than STD-VMAT for all cases. Conclusion: This work has shown that FFF beams are most beneficial for small-field irradiation such as PBI, and breast cancer patients could potentially benefit from the shortened beam-on time.
Collapse
|
6
|
Relationship between Treatment Plan Dosimetry, Toxicity, and Survival following Intensity-Modulated Radiotherapy, with or without Chemotherapy, for Stage III Inoperable Non-Small Cell Lung Cancer. Cancers (Basel) 2021; 13:cancers13235923. [PMID: 34885034 PMCID: PMC8657053 DOI: 10.3390/cancers13235923] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Revised: 11/20/2021] [Accepted: 11/22/2021] [Indexed: 12/25/2022] Open
Abstract
Simple Summary Various radiotherapy treatment methods are available for patients with stage III non-small-cell lung cancer (NSCLC). A multidisciplinary tumor board review is recommended to determine the best treatment strategy. In fit patients with inoperable tumors, concurrent chemoradiotherapy (cCRT) is preferred over sequential CRT (sCRT), due to better survival. Nonetheless, the use of cCRT in stage III NSCLC varies significantly, with concerns about treatment toxicity being a contributory factor. Many reports describing the relationship between overall survival, toxicity, and dosimetry in patients with locally advanced NSCLC are based on clinical trials, with strict criteria for patient selection, including good performance status, pulmonary function, etc. These trials have not always mandated the use of IMRT/VMAT. We therefore performed an institutional analysis to study the relationship between dosimetric parameters and overall survival and toxicity in patients with stage III NSCLC treated with IMRT/VMAT-based techniques in routine clinical practice. Abstract Concurrent chemoradiotherapy (cCRT) is the preferred treatment for stage III NSCLC because surgery containing multimodality treatment is often not appropriate. Alternatives, often for less fit patients, include sequential CRT and RT alone. Many reports describing the relationship between overall survival (OS), toxicity, and dosimetry are based on clinical trials, with strict criteria for patient selection. We performed an institutional analysis to study the relationship between dosimetric parameters, toxicity, and OS in inoperable patients with stage III NSCLC treated with (hybrid) IMRT/VMAT-based techniques in routine clinical practice. Eligible patients had undergone treatment with radical intent using cCRT, sCRT, or RT alone, planned to a total dose ≥ 50 Gy delivered in ≥15 fractions. All analyses were performed for two patient groups, (1) cCRT (n = 64) and (2) sCRT/RT (n = 65). The toxicity rate differences between the two groups were not significant, and OS was 29 and 17 months, respectively. For sCRT/RT, no dosimetric factors were associated with OS, whereas for cCRT, PTV-volume, esophagus V50 Gy, and contralateral lung V5 Gy were associated. cCRT OS was significantly lower in patients with esophagitis ≥ G2. The overall rate of ≥G3 pneumonitis was low (3%), and the rate of high-grade esophagitis the OS in this real-world patient population was comparable to those reported in clinical trials. Based on this hypothesis-generating data, more aggressive esophageal sparing merits consideration. Institutional auditing and benchmarking of the planning strategy, dosimetry, and outcome have an important role to play in the continuous quality improvement process.
Collapse
|
7
|
Dose Prediction Models Based on Geometric and Plan Optimization Parameter for Adjuvant Radiotherapy Planning Design in Cervical Cancer Radiotherapy. JOURNAL OF HEALTHCARE ENGINEERING 2021; 2021:7026098. [PMID: 34804459 PMCID: PMC8604605 DOI: 10.1155/2021/7026098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Accepted: 10/16/2021] [Indexed: 11/18/2022]
Abstract
The prediction of an additional space for the dose sparing of organs at risk (OAR) in radiotherapy is still difficult. In this pursuit, the present study was envisaged to find out the factors affecting the bladder and rectum dosimetry of cervical cancer. Additionally, the relationship between the dose-volume histogram (DVH) parameters and the geometry and plan dose-volume optimization parameters of the bladder/rectum was established to develop the dose prediction models and guide the planning design for lower OARs dose coverage directly. Thirty volume modulated radiation therapy (VMAT) plans from cervical cancer patients were randomly chosen to build the dose prediction models. The target dose coverage was evaluated. Dose prediction models were established by univariate and multiple linear regression among the dosimetric parameters of the bladder/rectum, the geometry parameters (planning target volume (PTV), volume of bladder/rectum, overlap volume of bladder/rectum (OV), and overlapped volume as a percentage of bladder/rectum volume (OP)), and corresponding plan dose-volume optimization parameters of the nonoverlapping structures (the structure of bladder/rectum outside the PTV (NOS)). Finally, the accuracy of the prediction models was evaluated by tracking d = (predicted dose-actual dose)/actual in additional ten VMAT plans. V 30, V 35, and V 40 of the bladder and rectum were found to be multiple linearly correlated with the relevant OP and corresponding dose-volume optimization parameters of NOS (regression R 2 > 0.99, P < 0.001). The variations of these models were less than 0.5% for bladder and rectum. Percentage of bladder and rectum within the PTV and the dose-volume optimization parameters of NOS could be used to predict the dose quantitatively. The parameters of NOS as a limited condition could be used in the plan optimization instead of limiting the dose and volume of the entire OAR traditionally, which made the plan optimization more unified and convenient and strengthened the plan quality and consistency.
Collapse
|
8
|
Kumar K, Chawla R. Nanocarriers-mediated therapeutics as a promising approach for treatment and diagnosis of lung cancer. J Drug Deliv Sci Technol 2021. [DOI: 10.1016/j.jddst.2021.102677] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
9
|
Yang B, Wong YS, Lam WW, Geng H, Huang CY, Tang KK, Law WK, Ho CC, Nam PH, Cheung KY, Yu SK. Initial clinical experience of patient-specific QA of treatment delivery in online adaptive radiotherapy using a 1.5 T MR-Linac. Biomed Phys Eng Express 2021; 7. [PMID: 33882471 DOI: 10.1088/2057-1976/abfa80] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Accepted: 04/21/2021] [Indexed: 11/11/2022]
Abstract
Purpose. This study aims to evaluate the performance of a commercial 1.5 T MR-Linac by analyzing its patient-specific quality assurance (QA) data collected during one full year of clinical operation.Methods and Materials. The patient-specific QA system consisted of offline delivery QA (DQA) and online calculation-based QA. Offline DQA was based on ArcCHECK-MR combined with an ionization chamber. Online QA was performed using RadCalc that calculated and compared the point dose calculation with the treatment planning system (TPS). A total of 24 patients with 189 treatment fractions were enrolled in this study. Gamma analysis was performed and the threshold that encompassed 95% of QA results (T95) was reported. The plan complexity metric was calculated for each plan and compared with the dose measurements to determine whether any correlation existed.Results. All point dose measurements were within 5% deviation. The mean gamma passing rates of the group data were found to be 96.8 ± 4.0% and 99.6 ± 0.7% with criteria of 2%/2mm and 3%/3mm, respectively. T95 of 87.4% and 98.2% was reported for the overall group with the two passing criteria, respectively. No statistically significant difference was found between adaptive treatments with adapt-to-position (ATP) and adapt-to-shape (ATS), whilst the category of pelvis data showed a better passing rate than other sites. Online QA gave a mean deviation of 0.2 ± 2.2%. The plan complexity metric was positively correlated with the mean dose difference whilst the complexity of the ATS cohort had larger variations than the ATP cohort.Conclusions. A patient-specific QA system based on ArcCHECK-MR, solid phantom and ionization chamber has been well established and implemented for validation of treatment delivery of a 1.5 T MR-Linac. Our QA data obtained over one year confirms that good agreement between TPS calculation and treatment delivery was achieved.
Collapse
Affiliation(s)
- B Yang
- Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong
| | - Y S Wong
- Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong
| | - W W Lam
- Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong
| | - H Geng
- Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong
| | - C Y Huang
- Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong
| | - K K Tang
- Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong
| | - W K Law
- Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong
| | - C C Ho
- Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong
| | - P H Nam
- Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong
| | - K Y Cheung
- Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong
| | - S K Yu
- Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong
| |
Collapse
|
10
|
Franzese C, Fogliata A, Loi M, Badalamenti M, Franceschini D, Comito T, Cozzi L, Reggiori G, Tomatis S, Scorsetti M. Dosimetric impact of volumetric modulated arc therapy for nasopharyngeal cancer treatment. ACTA ACUST UNITED AC 2021; 26:101-110. [PMID: 34046220 DOI: 10.5603/rpor.a2021.0017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2020] [Accepted: 12/21/2020] [Indexed: 11/25/2022]
Abstract
Background The purpose of the study was to evaluate the toxicity and outcome of nasopharyngeal carcinoma patients treated using 3-dimensional conformal radiotherapy (3DCRT) or volumetric modulated arc therapy (VMAT) technique. Materials and methods 68 patients treated between 2006 and 2018 were retrospectively analysed. Since 2009 patients received 3DCRT with 50/70 Gy to the elective/boost volumes in 35 fractions; from then, VMAT with simultaneous integrated boost (SIB) with 54.45/69.96 Gy in 33, or 54/66 Gy in 30 fractions. Induction chemotherapy was administered in 74% of the patients, concomitant cisplatinum in 87%. Acute and late toxicity data, progression-free survival PSF and overall survival OS, and toxicity correlations with dose metrics were reported. Results With a median follow-up of 64 months, complete remission at the last evaluation was in 68% of the patients, while 28% and 9% had locoregional relapse and distant disease, respectively. The 5- and 10-year progression free survival (PFS) rates were 62.7 ± 6.5% and 53.2 ± 8.7%, respectively. The 5- and 10-year OS rates were 78.9 ± 5.5% and 61.4 ± 9.2%, respectively. At the multivariate Cox analysis TNM stage (p = 0.02) and concomitant chemotherapy (p = 0.01) resulted significant for PFS, concomitant chemotherapy (p = 0.04) for OS.Improvements in acute toxicity were presented for VMAT patients due to its ability to spare OARs. Odds ratio (OR) for acute salivary toxicity, between VMAT and 3DCRT, was 4.67 (p = 0.02). Dosimetrically, salivary toxicity correlated with mean parotid dose (p = 0.05), dysphagia with laryngeal (p = 0.04) and mean oral cavity (p = 0.06) doses, when dose-volume histograms (DVHs) are corrected for fractionation. Conclusion This study is a proof of a significant benefit of the VMAT technique compared with 3DCRT in terms of side effects in nasopharynx patients, and adds dosimetric correlations.
Collapse
Affiliation(s)
- Ciro Franzese
- Humanitas Clinical and Research Hospital IRCCS, Radiotherapy Dept, Milan-Rozzano, Italy.,Humanitas University, Biomedical Science Dept, Milan-Rozzano, Italy
| | - Antonella Fogliata
- Humanitas Clinical and Research Hospital IRCCS, Radiotherapy Dept, Milan-Rozzano, Italy
| | - Mauro Loi
- Humanitas Clinical and Research Hospital IRCCS, Radiotherapy Dept, Milan-Rozzano, Italy
| | - Marco Badalamenti
- Humanitas Clinical and Research Hospital IRCCS, Radiotherapy Dept, Milan-Rozzano, Italy
| | - Davide Franceschini
- Humanitas Clinical and Research Hospital IRCCS, Radiotherapy Dept, Milan-Rozzano, Italy
| | - Tiziana Comito
- Humanitas Clinical and Research Hospital IRCCS, Radiotherapy Dept, Milan-Rozzano, Italy
| | - Luca Cozzi
- Humanitas Clinical and Research Hospital IRCCS, Radiotherapy Dept, Milan-Rozzano, Italy.,Humanitas University, Biomedical Science Dept, Milan-Rozzano, Italy
| | - Giacomo Reggiori
- Humanitas Clinical and Research Hospital IRCCS, Radiotherapy Dept, Milan-Rozzano, Italy
| | - Stefano Tomatis
- Humanitas Clinical and Research Hospital IRCCS, Radiotherapy Dept, Milan-Rozzano, Italy
| | - Marta Scorsetti
- Humanitas Clinical and Research Hospital IRCCS, Radiotherapy Dept, Milan-Rozzano, Italy.,Humanitas University, Biomedical Science Dept, Milan-Rozzano, Italy
| |
Collapse
|
11
|
Momin S, Gräfe JL, Georgiou K, Khan RF. Photon beam energy dependent single-arc volumetric modulated arc optimization. Phys Med 2021; 82:122-133. [PMID: 33611049 DOI: 10.1016/j.ejmp.2021.02.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2020] [Revised: 12/26/2020] [Accepted: 02/06/2021] [Indexed: 11/16/2022] Open
Abstract
PURPOSE The purpose of this work was to present a new single-arc mixed photon (6&18MV) VMAT (SAMP) optimization framework that concurrently optimizes for two photon energies with corresponding partial arc lengths. METHODS AND MATERIALS Owing to simultaneous optimization of energy dependent intensity maps and corresponding arc locations, the proposed model poses nonlinearity. Unique relaxation constraints based on McCormick approximations were introduced for linearization. Energy dependent intensity maps were then decomposed to generate apertures. Feasibility of the proposed framework was tested on a sample of ten prostate cancer cases with lateral separation ranging from 34 cm (case no.1) to 52 cm (case no.6). The SAMP plans were compared against single energy (6MV) VMAT (SE) plans through dose volume histograms (DVHs) and radiobiological parameters including normal tissue complication probability (NTCP) and equivalent uniform dose (EUD). RESULTS The contribution of higher energy photon beam optimized by the algorithm demonstrated an increase for cases with a lateral separation >40 cm. SAMP-VMAT notably improved bladder and rectum sparing in large size cases. Compared to single energy, SAMP-VMAT plans reduced bladder and rectum NTCP in cases with large lateral separation. With the exception of one case, SAMP-VMAT either improved or maintained femoral heads compared to SE-VMAT. SAMP-VMAT reduced the nontarget tissue integral dose in all ten cases. CONCLUSIONS A single-arc VMAT optimization framework comprising mixed photon energy partial arcs was presented. Overall results underline the feasibility and potential of the proposed approach for improving OAR sparing in large size patients without compromising the target homogeneity and coverage.
Collapse
Affiliation(s)
- Shadab Momin
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, MO, USA; Department of Physics, Ryerson University, Toronto, ON, Canada.
| | - James L Gräfe
- Department of Physics, Ryerson University, Toronto, ON, Canada
| | | | - Rao F Khan
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, MO, USA
| |
Collapse
|
12
|
Kontaxis C, Woodhead PL, Bol GH, Lagendijk JJW, Raaymakers BW. Proof-of-concept delivery of intensity modulated arc therapy on the Elekta Unity 1.5 T MR-linac. Phys Med Biol 2021; 66:04LT01. [PMID: 33361560 DOI: 10.1088/1361-6560/abd66d] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
In this work we present the first delivery of intensity modulated arc therapy on the Elekta Unity 1.5 T MR-linac. The machine's current intensity modulated radiation therapy based control system was modified suitably to enable dynamic delivery of radiation, for the purpose of exploring MRI-guided radiation therapy adaptation modes in a research setting. The proof-of-concept feasibility was demonstrated by planning and delivering two types of plans, each investigating the performance of different parts of a dynamic treatment. A series of fixed-speed arc plans was used to show the high-speed capabilities of the gantry during radiation, while several fully modulated prostate plans-optimised following the volumetric modulated arc therapy approach-were delivered in order to establish the performance of its multi-leaf collimator and diaphragms. These plans were delivered to Delta4 Phantom+ MR and film phantoms passing the clinical quality assurance criteria used in our clinic. In addition, we also performed some initial MR imaging experiments during dynamic therapy, demonstrating that the impact of radiation and moving gantry/collimator components on the image quality is negligible. These results show that arc therapy is feasible on the Elekta Unity system. The machine's high performance components enable dynamic delivery during fast gantry rotation and can be controlled in a stable fashion to deliver fully modulated plans.
Collapse
Affiliation(s)
- C Kontaxis
- Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, Utrecht 3584 CX, The Netherlands
| | | | | | | | | |
Collapse
|
13
|
Lyu Q, Neph R, O'Connor D, Ruan D, Boucher S, Sheng K. ROAD: ROtational direct Aperture optimization with a Decoupled ring-collimator for FLASH radiotherapy. Phys Med Biol 2021; 66:035020. [PMID: 33207321 DOI: 10.1088/1361-6560/abcbd0] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Ultra-high dose rate in radiotherapy (FLASH) has been shown to increase the therapeutic index with markedly reduced normal tissue toxicity and the same or better tumor cell killing. The challenge to achieve FLASH using x-rays, besides developing a high output linac, is to intensity-modulate the high-dose-rate x-rays so that the biological gain is not offset by the lack of physical dose conformity. In this study, we develop the ROtational direct Aperture optimization with a Decoupled ring-collimator (ROAD) to achieve simultaneous ultrafast delivery and complex dose modulation. The ROAD design includes a fast-rotating slip-ring linac and a decoupled collimator-ring with 75 pre-shaped multi-leaf-collimator (MLC) modules. The ring-source rotates at 1 rotation per second (rps) clockwise while the ring-collimator is either static or rotating at 1 rps counterclockwise, achieving 75 (ROAD-75) or 150 (ROAD-150) equal-angular beams for one full arc. The Direct Aperture Optimization (DAO) for ROAD was formulated to include a least-square dose fidelity, an anisotropic total variation term, and a single segment term. The FLASH dose (FD) and FLASH biological equivalent dose (FBED) were computed voxelwise, with the latter using a spatiotemporal model accounting for radiolytic oxygen depletion. ROAD was compared with clinical volumetric modulated arc therapy (VMAT) on a brain, a lung, a prostate, and a head and neck cancer patient. The mean dose rate of ROAD-75 and ROAD-150 are 76.2 Gy s-1 and 112 Gy s-1 respectively to deliver 25 Gy single-fraction dose in 1 s. With improved PTV homogeneity, ROAD-150 reduced (max, mean) OAR physical dose by (4.8 Gy, 6.3 Gy). The average R50 and integral dose of (VMAT, ROAD-75, ROAD-150) are (4.8, 3.2, 3.2) and (89, 57, 56) Gy×Liter, respectively. The FD and FBED showed model dependent FLASH effects. The novel ROAD design achieves ultrafast dose delivery and improves physical dosimetry compared with clinical VMAT, providing a potentially viable engineering solution for x-ray FLASH radiotherapy.
Collapse
Affiliation(s)
- Qihui Lyu
- Department of Radiation Oncology, University of California Los Angeles, Los Angeles, CA 90095, United States of America
| | - Ryan Neph
- Department of Radiation Oncology, University of California Los Angeles, Los Angeles, CA 90095, United States of America
| | - Daniel O'Connor
- Department of Mathematics and Statistics, University of San Francisco, San Francisco, CA 94143, United States of America
| | - Dan Ruan
- Department of Radiation Oncology, University of California Los Angeles, Los Angeles, CA 90095, United States of America
| | - Salime Boucher
- RadiaBeam Technologies, Santa Monica, CA 90404, United States of America
| | - Ke Sheng
- Department of Radiation Oncology, University of California Los Angeles, Los Angeles, CA 90095, United States of America
| |
Collapse
|
14
|
Liu YC, Chang HM, Lin HH, Lu CC, Lai LH. Dosimetric Comparison of Intensity-Modulated Radiotherapy, Volumetric Modulated Arc Therapy and Hybrid Three-Dimensional Conformal Radiotherapy/Intensity-Modulated Radiotherapy Techniques for Right Breast Cancer. J Clin Med 2020; 9:E3884. [PMID: 33260404 PMCID: PMC7760558 DOI: 10.3390/jcm9123884] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2020] [Revised: 11/23/2020] [Accepted: 11/26/2020] [Indexed: 12/21/2022] Open
Abstract
This study aimed to compare different types of right breast cancer radiotherapy planning techniques and to estimate the whole-body effective doses and the critical organ absorbed doses. The three planning techniques are intensity-modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT; two methods) and hybrid 3D-CRT/IMRT (three-dimensional conformal radiotherapy/intensity-modulated radiotherapy). The VMAT technique includes two methods to deliver a dose: non-continuous partial arc and continuous partial arc. A thermoluminescent dosimeter (TLD) is placed in the RANDO phantom to estimate the organ absorbed dose. Each planning technique applies 50.4 Gy prescription dose and treats critical organs, including the lung and heart. Dose-volume histogram was used to show the planning target volume (V95%), homogeneity index (HI), conformity index (CI), and other optimized indices. The estimation of whole-body effective dose was based on the International Commission on Radiation Protection (ICRP) Publication 60 and 103. The results were as follows: Continuous partial arc and non-continuous partial arc showed the best CI and HI. The heart absorbed doses in the continuous partial arc and hybrid 3D-CRT/IMRT were 0.07 ± 0.01% and 0% (V5% and V10%, respectively). The mean dose of the heart was lowest in hybrid 3D-CRT/IMRT (1.47 Gy ± 0.02). The dose in the left contralateral lung (V5%) was lowest in continuous partial arc (0%). The right ipsilateral lung average dose and V20% are lowest in continuous partial arc. Hybrid 3D-CRT/IMRT has the lowest mean dose to contralateral breast (organs at risk). The whole-body effective doses for ICRP-60 and ICRP-103 were highest in continuous partial arc (2.01 Sv ± 0.23 and 2.89 Sv ± 0.15, respectively). In conclusion, the use of VMAT with continuous arc has a lower risk of radiation pneumonia, while hybrid 3D-CRT/IMRT attain lower secondary malignancy risk and cardiovascular complications.
Collapse
Affiliation(s)
- Yi-Chi Liu
- Institute of Nuclear Engineering and Science, National Tsing Hua University, Hsinchu 30015 Taiwan;
- Department of Radiation Oncology, Wei Gong Memorial Hospital, Miaoli 35148, Taiwan
| | - Hung-Ming Chang
- Department of General Surgery, Wei Gong Memorial Hospital, Miaoli 35159, Taiwan;
| | - Hsin-Hon Lin
- Medical Physics Research Center, Institute for Radiological Research, Chang Gung University/Chang Gung Memorial Hospital, Taoyuan 33302, Taiwan;
- Department of Radiation Oncology, Chang Gung Memorial Hospital, Taoyuan 33305, Taiwan
- Department of Nuclear Medicine, Keelung Chang Gung Memorial Hospital, Keelung 20401, Taiwan
| | - Chia-Chun Lu
- Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu 30013, Taiwan;
| | - Lu-Han Lai
- Department of Medical Imaging and Radiological Technology, Yuanpei University of Medical Technology, Hsinchu 30015, Taiwan
| |
Collapse
|
15
|
Telarovic I, Krayenbuehl J, Grgic I, Tschanz F, Guckenberger M, Pruschy M, Unkelbach J. Probing spatiotemporal fractionation on the preclinical level. Phys Med Biol 2020; 65:22NT02. [PMID: 33179609 DOI: 10.1088/1361-6560/abbb75] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
In contrast to conventional radiotherapy, spatiotemporal fractionation (STF) delivers a distinct dose distribution in each fraction. The aim is to increase the therapeutic window by simultaneously achieving partial hypofractionation in the tumour along with near uniform fractionation in normal tissues. STF has been studied in silico under the assumption that different parts of the tumour can be treated in different fractions. Here, we develop an experimental setup for testing this key assumption on the preclinical level using high-precision partial tumour irradiation in an experimental animal model. We further report on an initial proof-of-concept experiment. We consider a reductionist model of STF in which the tumour is divided in half and treated with two complementary partial irradiations separated by 24 h. Precise irradiation of both tumour halves is facilitated by the image-guided small animal radiation research platform X-RAD SmART. To assess the response of tumours to partial irradiations, tumour growth experiments are conducted using mice carrying syngeneic subcutaneous tumours derived from MC38 colorectal adenocarcinoma cells. Tumour volumes were determined daily by calliper measurements and validated by CT-volumetry. We compared the growth of conventionally treated tumours, where the whole tumour was treated in one fraction, to the reductionist model of STF. We observed no difference in growth between the two groups. Instead, a reduction in the irradiated volume (where only one half of the tumour was irradiated) resulted in an intermediate response between full irradiation and unirradiated control. The results obtained by CT-volumetry supported the findings of the calliper-derived measurements. An experimental setup for precise partial tumour irradiation in small animals was developed, which is suited to test the assumption of STF that complementary parts of the tumour can be treated in different fractions on the preclinical level. An initial experiment supports this assumption, however, further experiments with longer follow-up and varying fractionation schemes are needed to provide additional support for STF.
Collapse
Affiliation(s)
- Irma Telarovic
- Department of Radiation Oncology, University Hospital Zurich, University of Zurich, Switzerland
| | | | | | | | | | | | | |
Collapse
|
16
|
Kamperis E, Kodona C, Hatziioannou K, Giannouzakos V. Complexity in Radiation Therapy: It's Complicated. Int J Radiat Oncol Biol Phys 2020; 106:182-184. [DOI: 10.1016/j.ijrobp.2019.09.003] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2019] [Revised: 08/29/2019] [Accepted: 09/06/2019] [Indexed: 12/11/2022]
|
17
|
Bokrantz R, Wedenberg M, Sandwall P. Dynamic conformal arcs for lung stereotactic body radiation therapy: A comparison with volumetric-modulated arc therapy. J Appl Clin Med Phys 2019; 21:103-109. [PMID: 31880386 PMCID: PMC6964764 DOI: 10.1002/acm2.12800] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2019] [Revised: 09/26/2019] [Accepted: 11/13/2019] [Indexed: 12/25/2022] Open
Abstract
This study constitutes a feasibility assessment of dynamic conformal arc (DCA) therapy as an alternative to volumetric‐modulated arc therapy (VMAT) for stereotactic body radiation therapy (SBRT) of lung cancer. The rationale for DCA is lower geometric complexity and hence reduced risk for interplay errors induced by respiratory motion. Forward planned DCA and inverse planned DCA based on segment‐weight optimization were compared to VMAT for single arc treatments of five lung patients. Analysis of dose‐volume histograms and clinical goal fulfillment revealed that DCA can generate satisfactory and near equivalent dosimetric quality to VMAT, except for complex tumor geometries. Segment‐weight optimized DCA provided spatial dose distributions qualitatively similar to those for VMAT. Our results show that DCA, and particularly segment‐weight optimized DCA, may be an attractive alternative to VMAT for lung SBRT treatments if the patient anatomy is favorable.
Collapse
Affiliation(s)
| | | | - Peter Sandwall
- Department of Radiation Oncology, OhioHealth, Mansfield, OH, USA
| |
Collapse
|
18
|
Jin X, Lin B, Chen D, Li L, Han C, Zhou Y, Zheng X, Gong C, Chen M, Xie C. Safety and outcomes of volumetric modulated arc therapy in the treatment of patients with inoperable lung cancer. J Cancer 2019; 10:2868-2873. [PMID: 31281463 PMCID: PMC6590029 DOI: 10.7150/jca.31260] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2018] [Accepted: 04/14/2019] [Indexed: 12/19/2022] Open
Abstract
Background: Published data on the effects and toxicities of volumetric modulated arc therapy (VMAT) in the management of inoperable lung cancer are scarce. Materials and methods: The clinical outcomes and pulmonary toxicities of 134 patients with consecutive inoperable lung cancer who underwent VMAT from March 2011 to September 2016 were retrospectively reviewed. The dosimetric and characteristic factors associated with acute radiation pneumonitis (RP) and pulmonary fibrosis were evaluated with univariate and multivariate analysis. Results: The average prescription doses to these 134 patients were 57.07±6.27 Gy (range 52-64 Gy). The overall median follow-up time was 18.6 months (range, 2-45 mo), with a median follow-up time for the surviving patients of 20 months (range, 7-45 mo). The 2-year progression-free survival (PFS) and overall survival (OS) for all patients were 18.2% and 38.4%, with a median PFS and OS of 7.6 months and 18.6 months, respectively. The percent of patients with grade III/higher RP and pulmonary fibrosis were 10.5% and 9.0%, respectively. V13 (p=0.02) and age (p=0.02) were independently associated with acute RP according to multivariate analysis. The constraints for lung dosimetric metrics V10,V13,V20 and V30 were approximately 49%,41%,26% and 17% in VMAT treatment of lung cancer to limit the RP rate < 10%. Conclusion: VMAT can be delivered safely with acceptable acute and late toxicities for lung cancer patients. Lung dosimetric metrics were valuable in predicting acute RP. A lung V13 constraint of 40% was helpful to limit the RP rate < 10% in VMAT treatment of lung cancer patients.
Collapse
Affiliation(s)
- Xiance Jin
- Radiation and Medical Oncology, the first Affiliated Hospital of Wenzhou Medical University, Wenzhou, China,325000
| | - Baochai Lin
- Radiation and Medical Oncology, the first Affiliated Hospital of Wenzhou Medical University, Wenzhou, China,325000
| | - Didi Chen
- Radiation and Medical Oncology, the first Affiliated Hospital of Wenzhou Medical University, Wenzhou, China,325000
| | - Lili Li
- Radiation and Medical Oncology, the first Affiliated Hospital of Wenzhou Medical University, Wenzhou, China,325000
| | - Ce Han
- Radiation and Medical Oncology, the first Affiliated Hospital of Wenzhou Medical University, Wenzhou, China,325000
| | - Yongqiang Zhou
- Radiation and Medical Oncology, the first Affiliated Hospital of Wenzhou Medical University, Wenzhou, China,325000
| | - Xiaomin Zheng
- Radiation and Medical Oncology, the first Affiliated Hospital of Wenzhou Medical University, Wenzhou, China,325000
| | - Changfei Gong
- Radiation and Medical Oncology, the first Affiliated Hospital of Wenzhou Medical University, Wenzhou, China,325000
| | - Mengfeng Chen
- Respiratory Department, Third People's Hospital of Yueqing, Wenzhou, China, 325600
| | - Congying Xie
- Radiation and Medical Oncology, the first Affiliated Hospital of Wenzhou Medical University, Wenzhou, China,325000
| |
Collapse
|
19
|
Chow JCL, Jiang R, Xu L. Dosimetric and radiobiological comparison of prostate VMAT plans optimized using the photon and progressive resolution algorithm. Med Dosim 2019; 45:14-18. [PMID: 31103251 DOI: 10.1016/j.meddos.2019.04.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2018] [Revised: 02/26/2019] [Accepted: 04/12/2019] [Indexed: 11/20/2022]
Abstract
This study compared the dosimetric and radiobiological parameters of prostate volumetric modulated arc therapy (VMAT) plans using different prescriptions optimized by the photon optimization (PO) and progressive resolution optimization (PRO) algorithm. A total of 20 prostate patients were selected retrospectively and divided into 2 groups of VMAT plans using prescriptions of 60 Gy/20 fx and 79 Gy/38 fx. Inverse treatment planning optimized by the PO and PRO algorithm based on the dual-arc technique was carried out by the Eclipse treatment planning system. The maximum dose, minimum dose, mean dose, dose-volume points, and dose-volume indices of the targets and organs at risk (OAR) were calculated from the plans. In addition, radiobiological parameters such as tumor control probability (TCP), normal tissue complication probability (NTCP), and equivalent uniform dose (EUD) of the targets and OAR were determined based on their dose-volume histograms (DVHs). A paired Student's t-test was carried out to compare the difference between mean dose-volume points, radiobiological parameters, and dose-volume indices. Two-tailed p < 0.05 was defined as having statistical difference. For prostate VMAT plans optimized by the PO algorithm, equal or slightly larger mean dose and TCP of the PTV (1% for 60 Gy/20 fx and 0.2% for 78 Gy/39 fx) were found by comparing to the PRO. These were followed by finding the slightly larger conformity index (CI; 0.927 vs 0.895 and 0.910 vs 0.904), larger or equal homogeneity index (HI; 0.054 vs 0.052 and 0.058 vs 0.058), and smaller gradient index (GI; 1.366 vs 2.288 and 1.585 vs 1.742) of the PTV using plans optimized by the PO vs PRO using prescriptions of 60 Gy/20 fx and 78 Gy/39 fx. For the OAR, we found that the mean doses, NTCPs, and EUDs of the rectum, bladder, and femur were slightly larger for plans optimized by the PO algorithm compared to the PRO, though both optimization algorithms satisfied all the dose-volume criteria and objectives in the inverse planning. Both the PO and PRO algorithm can generate prostate VMAT plans fulfilling the required dose-volume criteria. It is concluded that plans optimized by the PO algorithm can produce prostate plan with very similar quality compared to PRO.
Collapse
Affiliation(s)
- James C L Chow
- Radiation Medicine Program, Princess Margaret Cancer Centre, University Health Network, Toronto, ON M5G 1X6, Canada; Department of Radiation Oncology, University of Toronto, Toronto, ON M5S 3E2, Canada.
| | - Runqing Jiang
- Medical Physics Department, Grand River Regional Cancer Centre, Kitchener, ON N2G 1G3, Canada; Department of Physics, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| | - Lu Xu
- Department of Medical Biophysics, Western University, London, ON N6A 3K7, Canada
| |
Collapse
|
20
|
Milan T, Grogan G, Ebert MA, Rowshanfarzad P. Evaluation of the Impact of the Linac MLC and Gantry Sag in volumetric modulated arc therapy. Med Phys 2019; 46:1984-1994. [PMID: 30870581 DOI: 10.1002/mp.13491] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2018] [Revised: 02/28/2019] [Accepted: 03/06/2019] [Indexed: 11/08/2022] Open
Abstract
PURPOSE Mechanical sag in the radiotherapy linear accelerator gantry and multi-leaf collimator (MLC) carriage effectively causes systematic deviations in the isocenter with respect to gantry angle. To minimize the impact of this error on treatment, a tolerance value of a 1-mm mechanical isocenter shift is commonly accepted for intensity-modulated radiation therapy quality assurance (QA). However, this tolerance value has not been firmly established for volumetric modulated arc therapy (VMAT) treatments. The purpose of this study is therefore to evaluate the impact of gantry and MLC carriage sag on VMAT clinical performance. METHODS A published dataset of Elekta and Varian sag measurements served as a starting point for the investigation. Typical sag profiles were chosen and modeled as continuous isocenter deviations in three dimensions. The data were then incorporated into existing Digital Imaging and Communications in Medicine protocol, extended for radiotherapy plans via a "beam-splitting" algorithm. Three treatment sites were investigated in parallel: head and neck, prostate, and prostate with surrounding lymph nodes. Monte Carlo-simulated dose distributions were obtained for varying magnifications of the modeled sag. The resulting dose distributions, including that for no error, were compared qualitatively and quantitatively, against multiple metrics. RESULTS The dose-volume histograms (DVHs) for all plans exhibited a decrease in planning target volume (PTV) dose uniformity with increasing sag magnification, whereas dose to organs at risk exhibited no coherent trend. The prostate plan was shown to be the most vulnerable to mechanical sag across all considered metrics. However, all plans with peak isocenter deviation less than 1 mm were well within typical cutoff points for each metric. CONCLUSIONS All avenues of investigation presented substantiate the commonly accepted tolerance value of a 1-mm peak isocenter shift in annual linac QA.
Collapse
Affiliation(s)
- Thomas Milan
- Department of Radiation Oncology, Sir Charles Gairdner Hospital, Nedlands, WA, 6009, Australia.,Department of Physics, University of Western Australia, Crawley, WA, 6009, Australia
| | - Garry Grogan
- Department of Radiation Oncology, Sir Charles Gairdner Hospital, Nedlands, WA, 6009, Australia
| | - Martin A Ebert
- Department of Radiation Oncology, Sir Charles Gairdner Hospital, Nedlands, WA, 6009, Australia.,Department of Physics, University of Western Australia, Crawley, WA, 6009, Australia
| | - Pejman Rowshanfarzad
- Department of Physics, University of Western Australia, Crawley, WA, 6009, Australia
| |
Collapse
|
21
|
Antico M, Prinsen P, Cellini F, Fracassi A, Isola AA, Cobben D, Fontanarosa D. Real-time adaptive planning method for radiotherapy treatment delivery for prostate cancer patients, based on a library of plans accounting for possible anatomy configuration changes. PLoS One 2019; 14:e0213002. [PMID: 30818345 PMCID: PMC6394960 DOI: 10.1371/journal.pone.0213002] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2018] [Accepted: 02/13/2019] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND AND PURPOSE In prostate cancer treatment with external beam radiation therapy (EBRT), prostate motion and internal changes in tissue distribution can lead to a decrease in plan quality. In most currently used planning methods, the uncertainties due to prostate motion are compensated by irradiating a larger treatment volume. However, this could cause underdosage of the treatment volume and overdosage of the organs at risk (OARs). To reduce this problem, in this proof of principle study we developed and evaluated a novel adaptive planning method. The strategy proposed corrects the dose delivered by each beam according to the actual position of the target in order to produce a final dose distribution dosimetrically as similar as possible to the prescribed one. MATERIAL AND METHODS Our adaptive planning method was tested on a phantom case and on a clinical case. For the first, a pilot study was performed on an in-silico pelvic phantom. A "library" of intensity modulated RT (IMRT) plans corresponding to possible positions of the prostate during a treatment fraction was generated at planning stage. Then a 3D random walk model was used to simulate possible displacements of the prostate during the treatment fraction. At treatment stage, at the end of each beam, based on the current position of the target, the beam from the library of plans, which could reproduce the best approximation of the prescribed dose distribution, was selected and delivered. In the clinical case, the same approach was used on two prostate cancer patients: for the first a tissue deformation was simulated in-silico and for the second a cone beam CT (CBCT) taken during the treatment was used to simulate an intra-fraction change. Then, dosimetric comparisons with the standard treatment plan and, for the second patient, also with an isocenter shift correction, were performed. RESULTS For the phantom case, the plan generated using the adaptive planning method was able to meet all the dosimetric requirements and to correct for a misdosage of 13% of the dose prescription on the prostate. For the first clinical case, the standard planning method caused underdosage of the seminal vesicles, respectively by 5% and 4% of the prescribed dose, when the position changes for the target were correctly taken into account. The proposed adaptive planning method corrected any possible missed target coverage, reducing at the same time the dose on the OARs. For the second clinical case, both with the standard planning strategy and with the isocenter shift correction target coverage was significantly worsened (in particular uniformity) and some organs exceeded some toxicity objectives. While with our approach, the most uniform coverage for the target was produced and systematically the lowest toxicity values for the organs at risk were achieved. CONCLUSIONS In our proof of principle study, the adaptive planning method performed better than the standard planning and the isocenter shift methods for prostate EBRT. It improved the coverage of the treatment volumes and lowered the dose to the OARs. This planning method is particularly promising for hypofractionated IMRT treatments in which a higher precision and control on dose deposition are needed. Further studies will be performed to test more extensively the proposed adaptive planning method and to evaluate it at a full clinical level.
Collapse
Affiliation(s)
- Maria Antico
- School of Chemistry, Physics and Mechanical Engineering, Queensland University of Technology, Brisbane, Queensland, Australia
- Institute of Health & Biomedical Innovation, Queensland University of Technology, Brisbane, QLD, Australia
- Delft University of Technology, Delft, The Netherlands
- Philips Research, Oncology Solutions Department, Eindhoven, The Netherlands
| | - Peter Prinsen
- Philips Research, Oncology Solutions Department, Eindhoven, The Netherlands
| | - Francesco Cellini
- UOC Radioterapia Oncologica, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Istituto di Radiologia, Fondazione Policlinico A. Gemelli, IRCCS—Università Cattolica Sacro Cuore, Roma, Italia
| | - Alice Fracassi
- Philips Research, Oncology Solutions Department, Eindhoven, The Netherlands
- University of Rome Tor Vergata, Rome, Italy
| | - Alfonso A. Isola
- Philips Research, Oncology Solutions Department, Eindhoven, The Netherlands
| | - David Cobben
- North West Cancer Centre, Altnagelvin Hospital, Derry-Londonderry, Northern Ireland
- The University of Manchester, Division of Cancer Studies, School of Medical Sciences, Faculty of Biology, Medicine and Health, Manchester, United Kingdom
- The Christie NHS Foundation Trust, Clinical Oncology, Manchester, United Kingdom
| | - Davide Fontanarosa
- Institute of Health & Biomedical Innovation, Queensland University of Technology, Brisbane, QLD, Australia
- School of Clinical Sciences, Queensland University of Technology, Gardens Point Campus, Brisbane, QLD, Australia
- * E-mail:
| |
Collapse
|
22
|
Sun Y, Liu G, Chen W, Chen T, Liu P, Zeng Q, Hong J, Wei R. Dosimetric comparisons of craniospinal axis irradiation using helical tomotherapy, volume-modulated arc therapy and intensity-modulated radiotherapy for medulloblastoma. Transl Cancer Res 2019; 8:191-202. [PMID: 35116748 PMCID: PMC8797767 DOI: 10.21037/tcr.2019.01.30] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2018] [Accepted: 01/15/2019] [Indexed: 11/06/2022]
Abstract
Background To evaluate the potential dosimetric gains of helical tomotherapy (HT) versus intensity-modulated radiotherapy (IMRT) and volume-modulated arc therapy (VMAT) for craniospinal axis irradiation (CSI) of medulloblastoma. Methods A total of 36 treatment plans were calculated retrospectively for 12 patients with medulloblastoma receiving CSI using HT with TomoTherapy Hi-Art Software (Version 2.0.7) (Accuray, Madison, WI, USA). For each case, the other two different delivery techniques were re-planned with IMRT/VMAT optimized with Eclipse treatment planning system (TPS) (Version 11.0.31). Homogeneity index (HI) and conformity index (CI) of the planning target volume (PTV) and organs at risk (OARs) sparing were analyzed. Differences in plans were evaluated using paired-samples t-test for various dosimetric parameters. Results HT yielded the highest CI in all PTV coverage including PTV of gross tumor volume (PGTV) (HT: 0.7163; VMAT: 0.6688; IMRT: 0.6096), PTVbrain (HT: 0.8490; VMAT: 0.8384; IMRT: 0.7815) and PTVspine (HT: 0.5904; VMAT: 0.5862; IMRT: 0.5797). Meanwhile, HT yielded better HI in PGTV (HT: 0.0543; VMAT: 0.0759; IMRT: 0.0736), PTVbrain (HT: 0.5525; VMAT: 0.5619; IMRT: 0.5554) and PTVspine (HT: 0.0700; VMAT: 0.0782; IMRT: 0.0877). As for OARs, HT demonstrated marked superiority in critical organs including maximal/mean doses of brainstem PRV, optical chiasm and optic nerves. Conclusions For CSI of medulloblastoma, HT offers superior outcomes in terms of PTV conformity, PTV homogeneity and critical OAR sparing as compared with IMRT/VMAT.
Collapse
Affiliation(s)
- Yangqing Sun
- Department of Oncology, Xiangya Hospital, Central South University, Changsha 410008, China
| | - Gui Liu
- Department of Oncology, Xiangya Hospital, Central South University, Changsha 410008, China
| | - Wen Chen
- Department of Oncology, Xiangya Hospital, Central South University, Changsha 410008, China
| | - Taili Chen
- Department of Oncology, Xiangya Hospital, Central South University, Changsha 410008, China
| | - Pei Liu
- Department of Oncology, Xiangya Hospital, Central South University, Changsha 410008, China
| | - Qian Zeng
- Department of Oncology, Xiangya Hospital, Central South University, Changsha 410008, China
| | - Jidong Hong
- Department of Oncology, Xiangya Hospital, Central South University, Changsha 410008, China
| | - Rui Wei
- Department of Oncology, Xiangya Hospital, Central South University, Changsha 410008, China
| |
Collapse
|
23
|
Design and Evaluation of a MEMS Magnetic Field Sensor-Based Respiratory Monitoring and Training System for Radiotherapy. SENSORS 2018; 18:s18092742. [PMID: 30134526 PMCID: PMC6163714 DOI: 10.3390/s18092742] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/19/2018] [Revised: 08/16/2018] [Accepted: 08/18/2018] [Indexed: 12/25/2022]
Abstract
The patient’s respiratory pattern and reproducibility are important factors affecting the accuracy of radiotherapy for lung cancer or liver cancer cases. Therefore, respiration training is required to induce respiration regularity before radiotherapy. However, the need for specialized personnel, space, and time-consuming training represent limitations. To solve these problems, we have developed a respiratory monitoring and training system based on a micro-electro-mechanical-system (MEMS) magnetic sensor. This system consists of a small attaching magnet, a sensor, and a breathing pattern output device. In this study, we evaluated the performance of the signal measurement in the developed system based on the various respiratory cycles, the amplitudes, and the position angles of the magnet and the sensor. The system can provide a more accurate breathing signal graph with lower measurement error and higher spatial resolution than conventional sensor methods by using additional magnet. In addition, it is possible the patient to monitor and train breathing himself by making it easy to carry and use without restriction of time and space.
Collapse
|
24
|
Dosimetric variations in calculation grid size in prostate VMAT: a dose-volume histogram analysis using the Gaussian error function. JOURNAL OF RADIOTHERAPY IN PRACTICE 2018. [DOI: 10.1017/s1460396917000619] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AbstractBackgroundVarying the calculation grid size can change the results of dose-volume and radiobiological parameters in a treatment plan, and therefore has an impact on the treatment planning quality assurance.PurposeThis study investigated the dosimetric influence of the calculation grid size variation in the prostate volumetric modulated arc therapy (VMAT) plan.Methods and materialsDose distributions of 10 prostate VMAT plans were acquired using calculation grid sizes of 1–5 mm. Dose-volume histogram (DVH) analysis was carried out to determine the dose-volume variation corresponding to the grid size change using the Gaussian error function (GEF). At the same time, dose-volume points, dose-volume parameters and radiobiological parameters were calculated based on DVHs of targets and organs at risk (OARs) for each grid size.ResultsComparing percentage variations of GEF parameters between the planning target volume (PTV) and clinical target volume (CTV), GEF parameters of the PTV were found varied more significantly than the CTV. This resulted in larger variations of dose-volume (%ΔCI=40·02 versus 13·55%, %ΔHI=12·45 versus 2·93% and %ΔGI=0·22 versus 0·06%) and radiobiological parameters (%ΔTCP=0·61 versus 0·25% and %ΔEUD=2·11 versus 0·26%) of the PTV compared with CTV. For OARs, the rectal wall showed a larger dose-volume variation than the rectum. However, similar dose-volume variation due to grid size change was not found in the bladder, bladder wall and femur.ConclusionsKnowing the dosimetric variation in this study is important to the radiotherapy staff in the quality assurance for the prostate VMAT planning.
Collapse
|
25
|
Volumetric modulated arc therapy of head-and-neck cancer on a fast-rotating O-ring linac: Plan quality and delivery time comparison with a C-arm linac. Radiother Oncol 2018; 128:479-484. [PMID: 29739713 DOI: 10.1016/j.radonc.2018.04.021] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2017] [Revised: 04/13/2018] [Accepted: 04/17/2018] [Indexed: 12/25/2022]
Abstract
BACKGROUND AND PURPOSE Linac improvements in gantry speed, leaf speed and dose rate may increase the time-efficiency of volumetric modulated arc therapy (VMAT) delivery. The plan quality achievable with faster VMAT however remains to be investigated. In this study, a fast-rotating O-ring linac with fast-moving leaves is compared with a C-arm linac in terms of plan quality and delivery time for VMAT of head-and-neck cancer (HNC). MATERIAL AND METHODS For 30 patients with HNC, treatment planning was performed using dual-arc (HA2) and triple-arc (HA3) VMAT on a Halcyon fast-rotating O-ring linac and using dual-arc VMAT on a TrueBeam C-arm linac (TB2). Target coverage metrics and complication probabilities were compared. Plan delivery was verified using 3%/3 mm gamma-index analysis of helical diode array measurements. Volumetric image acquisition and plan delivery times were compared. RESULTS All studied VMAT-techniques fulfilled the target coverage objectives. D2% to the boost volume was higher for HA2 (median 103.7%, 1st-3rd quartile [103.5%;104.0%]) and HA3 (103.2% [103.0%;103.7%)] than for TB2 (102.6% [102.3%;103.0%)], resulting in an increased boost target dose heterogeneity for HA2 and HA3. Complication probabilities were comparable between HA2 and TB2, while HA3 showed a xerostomia probability reduction (0.8% [0.2%;1.8%]) and dysphagia probability reduction (1.0% [0.2%;1.8%]) compared with TB2. Gamma-index agreement scores were never below 93.0% for HA2, HA3 and TB2. Volumetric imaging and plan delivery time was shorter for HA2 (1 m 24 s ± 1 s) and HA3 (1 m 54 s ± 1 s) than for TB2 (2 m 47 s ± 1 s). CONCLUSION For VMAT of HNC, the fast-rotating O-ring linac at least maintains the plan quality of two arcs on a C-arm linac while reducing the image acquisition and plan delivery time.
Collapse
|
26
|
A dosimetric phantom study of thoracic radiotherapy based on three-dimensional modeling of mediastinal lymph nodes. Oncol Lett 2018; 15:5634-5642. [PMID: 29556300 PMCID: PMC5844048 DOI: 10.3892/ol.2018.8084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2017] [Accepted: 11/16/2017] [Indexed: 11/05/2022] Open
Abstract
The aim of the present study was to investigate the optimal strategy and dosimetric measurement of thoracic radiotherapy based on three-dimensional (3D) modeling of mediastinal lymph nodes (MLNs). A 3D model of MLNs was constructed from a Chinese Visible Human female dataset. Image registration and fusion between reconstructed MLNs and original chest computed tomography (CT) images was conducted in the Eclipse™ treatment planning system (TPS). There were three plans, including 3D conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT), which were designed based on 10 cases of simulated lung lesions (SLLs) and MLNs. The quality of these plans was evaluated via examining indexes, including conformity index (CI), homogeneity index and clinical target volume (CTV) coverage. Dose-volume histogram analysis was performed on SLL, MLNs and organs at risk (OARs). A Chengdu Dosimetric Phantom (CDP) was then drilled at specific MLNs according to 20 patients with thoracic tumors and of a medium-build. These plans were repeated on fused MLNs and CDP CT images in the Eclipse™ TPS. Radiation doses at the SLLs and MLNs of the CDP were measured and compared with calculated doses. The established 3D MLN model demonstrated the spatial location of MLNs and adjacent structures. Precise image registration and fusion were conducted between reconstructed MLNs and the original chest CT or CDP CT images. IMRT demonstrated greater values in CI, CTV coverage and OAR (lungs and spinal cord) protection, compared with 3D-CRT and VMAT (P<0.05). The deviation between the measured and calculated doses was within ± 10% at SLL, and at the 2R and 7th MLN stations. In conclusion, the 3D MLN model can benefit plan optimization and dosimetric measurement of thoracic radiotherapy, and when combined with CDP, it may provide a tool for clinical dosimetric monitoring.
Collapse
|
27
|
Yang B, Geng H, Ding Y, Kong CW, Cheung CW, Chiu TL, Lam WW, Cheung KY, Yu SK. Development of a novel methodology for QA of respiratory-gated and VMAT beam delivery using Octavius 4D phantom. Med Dosim 2018; 44:83-90. [PMID: 29602598 DOI: 10.1016/j.meddos.2018.02.008] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2017] [Revised: 12/28/2017] [Accepted: 02/15/2018] [Indexed: 11/26/2022]
Abstract
The objective of this study was to develop and evaluate a series of quality assurance (QA) techniques based on Octavius 4D phantom for testing of respiratory-gated treatment delivery, integrity of dose rate vs gantry speed in volumetric-modulated arc therapy (VMAT) commissioning, and multileaf collimator (MLC) positioning accuracy of a linear accelerator. An Octavius 4D phantom capable of rotating with the gantry and recording the detector signal with a sampling rate of 10 Hz was isocentrally set up and an inclinometer was also installed to measure the gantry angle simultaneously. A simple arc test was created and delivered with gating function activated to measure the timing accuracy of the gating window. A tailor-made dose rate vs gantry speed plan was also designed to test the accuracy of measured dose rate, gantry speed, and actual control points. All experiments were conducted while machine log files were collected for comparison. The variations of beam flatness, symmetry, and field size were analyzed as a function of gantry angle to evaluate the influence from the modulation of dose rate and gantry speed. MLC position accuracy was evaluated based on specific garden fence plans. The time of gating window was measured to be less than 10-millisecond deviation from the log data. Gantry backlash was observed and quantified to be 1.72° with an extra stabilization time of 1.16 seconds for a gating arc with gantry speed of 6°/s. In the dose rate vs gantry speed test, the mean deviation between measured gantry angle and log data was less than 0.2° after a time delay of 0.25 second was corrected. The measured dose rate agreed with the log data very well with a mean deviation of 0.05%, and even the transit of modulation was tracked successfully. There was a statistically significant difference on the variation of beam parameters between a VMAT plan and a simple arc plan. The induced MLC position errors were detected with an accuracy of 0.05 mm. The leaf position reproducibility was found to be better than 0.02 mm, whereas the routine MLC position accuracy was better than 0.1 mm. A time-resolved method using Octavius 4D phantom has been developed and proven to be convenient for respiratory gating QA, dose rate vs gantry speed test, and MLC QA. Gating time, dose rate, and gantry speed-induced leave position error could be directly measured with high accuracy after comparison with the machine log data. This study also highlights the capability of the phantom in quantifying the variation of flatness, symmetry, and field size during gantry rotation.
Collapse
Affiliation(s)
- Bin Yang
- Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong.
| | - Hui Geng
- Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong
| | - Ying Ding
- Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong
| | - Chi Wah Kong
- Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong
| | - Chi Wai Cheung
- Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong
| | - Tin Lok Chiu
- Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong
| | - Wai Wang Lam
- Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong
| | - Kin Yin Cheung
- Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong
| | - Siu Ki Yu
- Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong
| |
Collapse
|
28
|
Mallory M, Pokhrel D, Badkul R, Jiang H, Lominska C, Wang F. Volumetric modulated arc therapy treatment planning of thoracic vertebral metastases using stereotactic body radiotherapy. J Appl Clin Med Phys 2018; 19:54-61. [PMID: 29349867 PMCID: PMC5849835 DOI: 10.1002/acm2.12252] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2017] [Revised: 10/05/2017] [Accepted: 11/15/2017] [Indexed: 12/31/2022] Open
Abstract
Purpose/Objectives To retrospectively evaluate the plan quality, treatment efficiency, and accuracy of volumetric modulated arc therapy (VMAT) plans for thoracic spine metastases using stereotactic body radiotherapy (SBRT). Materials/Methods Seven patients with thoracic vertebral metastases treated with noncoplanar hybrid arcs (NCHA) (1 to 2 3D‐conformal partial arcs +7 to 9 IMRT beams) were re‐optimized with VMAT plans using three coplanar arcs. Tumors were located between T2 and T7 and PTVs ranged between 24.3 and 240.1 cc (median 48.1 cc). All prescriptions were 30 Gy in 5 fractions with 6 MV beams treated using the Novalis Tx linac equipped with high definition multileaf collimators (HDMLC). MR images were fused with planning CTs for target and OAR contouring. Plans were compared for target coverage using conformality index (CI), homogeneity index (HI), D90, D98, D2, and Dmedian. Normal tissue sparing was evaluated by comparing doses to the spinal cord (Dmax, D0.35, and D1.2 cc), esophagus (Dmax and D5 cc), heart (Dmax, D15 cc), and lung (V5 and V10). Data analysis was performed with a two‐sided t‐test for each set of parameters. Dose delivery efficiency and accuracy of each VMAT plan was assessed via quality assurance (QA) using a MapCHECK device. The Beam‐on time (BOT) was recorded, and a gamma index was used to compare dose agreement between the planned and measured doses. Results VMAT plans resulted in improved CI (1.02 vs. 1.36, P = 0.05), HI (0.14 vs. 0.27, P = 0.01), D98 (28.4 vs. 26.8 Gy, P = 0.03), D2 (32.9 vs. 36.0 Gy, P = 0.02), and Dmedian (31.4 vs. 33.7 Gy, P = 0.01). D90 was improved but not statistically significant (30.4 vs. 31.0 Gy, P = 0.38). VMAT plans showed statistically significant improvements in normal tissue sparing: Esophagus Dmax (22.5 vs. 27.0 Gy, P = 0.03), Esophagus 5 cc (17.6 vs. 21.5 Gy, P = 0.02), and Heart Dmax (13.1 vs. 15.8 Gy, P = 0.03). Improvements were also observed in spinal cord and lung sparing as well but were not statistically significant. The BOT showed significant reduction for VMAT, 4.7 ± 0.6 min vs. 7.1 ± 1 min for NCHA (not accounting for couch kicks). VMAT plans demonstrated an accurate dose delivery of 95.5 ± 1.0% for clinical gamma passing rate of 3%/3 mm criteria, which was similar to NCHA plans. Conclusions VMAT plans have shown improved dose distributions and normal tissue sparing compared to NCHA plans. Significant reductions in treatment time could potentially minimize patient discomfort and intrafraction movement errors. VMAT planning for SBRT is an attractive option for the treatment of metastases to thoracic vertebrae, and further investigation using alternative fractionation schedules is warranted.
Collapse
Affiliation(s)
- Matthew Mallory
- Department of Radiation Oncology, The University of Kansas Cancer Center, Kansas City, KS, USA
| | - Damodar Pokhrel
- Department of Radiation Medicine, University of Kentucky Chandler Hospital, Lexington, KY, USA
| | - Rajeev Badkul
- Department of Radiation Oncology, The University of Kansas Cancer Center, Kansas City, KS, USA
| | - Hongyu Jiang
- Department of Radiation Oncology, The University of Kansas Cancer Center, Kansas City, KS, USA
| | - Christopher Lominska
- Department of Radiation Oncology, The University of Kansas Cancer Center, Kansas City, KS, USA
| | - Fen Wang
- Department of Radiation Oncology, The University of Kansas Cancer Center, Kansas City, KS, USA
| |
Collapse
|
29
|
Dose-volume and radiobiological dependence on the calculation grid size in prostate VMAT planning. Med Dosim 2018; 43:383-389. [PMID: 29373184 DOI: 10.1016/j.meddos.2017.12.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2017] [Revised: 09/27/2017] [Accepted: 12/15/2017] [Indexed: 02/03/2023]
Abstract
This study evaluated the effects of dose-volume and radiobiological dependence on the calculation grid size in prostate volumetric-modulated arc therapy (VMAT) planning. Ten patients with prostate cancer were selected for this retrospective treatment planning study. Prostate VMAT plans were created for the patients using the 6 MV photon beam produced by a Varian TrueBEAM linac with the calculation grid size equal to 1, 2, 2.5, 3, 4, and 5 mm. Dose-volume histograms (DVHs) of targets and organs at risk were generated for different grid sizes. We calculated the radiobiological parameters of the tumor control probability (TCP) of clinical target volume (CTV) and planning target volume (PTV), and the normal tissue complication probability (NTCP) of organs at risk (rectal wall, rectum, bladder wall, bladder, left femur, and right femur). The homogeneity, conformity, and gradient indexes of CTV and PTV were calculated for different grid sizes. The TCP of PTV was found decreasing with a rate of 0.06%/mm when the calculation grid size increased from 1 to 5 mm. On the other hand, both NTCPs of rectal wall and rectum were found decreasing with rates of 0.03%/mm and 0.05%/mm, respectively, with an increase of grid size. The homogeneity index of PTV increased with a rate of 0.57/mm of the calculation grid size, whereas the conformity index of PTV decreased with a rate of 0.0075/mm. The gradient index of PTV was found increasing with a rate equal to 0.05/mm. In prostate VMAT planning, variations of dose-volume and radiobiological parameters with calculation grid size on PTV, rectal wall, and rectum were more significant than those of CTV and other organs at risk such as bladder wall, bladder, and femurs. Results in this study are important in the treatment planning quality assurance when the calculation grid size is varied to compromise a shorter dose computing time.
Collapse
|
30
|
Local recurrences after curative IMRT for HNSCC: Effect of different GTV to high-dose CTV margins. Radiother Oncol 2018; 126:48-55. [DOI: 10.1016/j.radonc.2017.11.024] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2017] [Revised: 11/27/2017] [Accepted: 11/27/2017] [Indexed: 01/29/2023]
|
31
|
Cozzi L, Lohr F, Fogliata A, Franceschini D, De Rose F, Filippi AR, Guidi G, Vanoni V, Scorsetti M. Critical appraisal of the role of volumetric modulated arc therapy in the radiation therapy management of breast cancer. Radiat Oncol 2017; 12:200. [PMID: 29258539 PMCID: PMC5735809 DOI: 10.1186/s13014-017-0935-4] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2017] [Accepted: 12/05/2017] [Indexed: 02/06/2023] Open
Abstract
Background The aim of this review is the critical appraisal of the current use of volumetric modulated arc therapy for the radiation therapy management of breast cancer. Both clinical and treatment planning studies were investigated. Material and methods A Pubmed/MEDLINE search of the National Library of Medicine was performed to identify VMAT and breast related articles. After a first order rejection of the irrelevant findings, the remaining articles were grouped according to two main categories: clinical vs. planning studies and to some sub-categories (pointing to significant technical features). Main areas of application, dosimetric and clinical findings as well as areas of innovations were defined. Results A total of 131 articles were identified and of these, 67 passed a first order selection. Six studies reported clinical results while 61 treatment dealed with treatment planning investigations. Among the innovation lines, the use of high intensity photon beams (flattening filter free), altered fractionation schemes (simultaneous integrated boost, accelerated partial breast irradiation, single fraction), prone positioning and modification of standard VMAT (use of dynamic trajectories or hybrid VMAT methods) resulted among the main relevant fields of interest. Approximately 10% of the publications reported upon respiratory gating in conjunction with VMAT. Conclusions The role of VMAT in the radiation treatment of breast cancer seems to be consolidated in the in-silico arena while still limited evidence and only one phase II trial appeared in literature from the clinical viewpoint. More clinical reports are needed to fully proove the expected dosimetric benefits demonstrated in the planning investigations.
Collapse
Affiliation(s)
- Luca Cozzi
- Radiotherapy and Radiosurgery Department, Humanitas Research Hospital, Via Manzoni 56, 20089, Rozzano-Milan, Italy. .,Department of Biomedical Sciences, Humanitas University, Rozzano, Italy.
| | - Frank Lohr
- Radiation Oncology Department, Ospedaliero-Universitaria, Modena, Italy
| | - Antonella Fogliata
- Radiotherapy and Radiosurgery Department, Humanitas Research Hospital, Via Manzoni 56, 20089, Rozzano-Milan, Italy
| | - Davide Franceschini
- Radiotherapy and Radiosurgery Department, Humanitas Research Hospital, Via Manzoni 56, 20089, Rozzano-Milan, Italy
| | - Fiorenza De Rose
- Radiotherapy and Radiosurgery Department, Humanitas Research Hospital, Via Manzoni 56, 20089, Rozzano-Milan, Italy
| | - A R Filippi
- Department of Radiation Oncology, Osp. S. Luigi Gonzaga University Hospital, Torino, Italy
| | - Gabriele Guidi
- Medical Physics Department, Az. Ospedaliero-Universitaria, Modena, Italy
| | | | - Marta Scorsetti
- Radiotherapy and Radiosurgery Department, Humanitas Research Hospital, Via Manzoni 56, 20089, Rozzano-Milan, Italy.,Department of Biomedical Sciences, Humanitas University, Rozzano, Italy
| |
Collapse
|
32
|
Xu Y, Deng W, Yang S, Li P, Kong Y, Tian Y, Liao Z, Chen M. Dosimetric comparison of the helical tomotherapy, volumetric-modulated arc therapy and fixed-field intensity-modulated radiotherapy for stage IIB-IIIB non-small cell lung cancer. Sci Rep 2017; 7:14863. [PMID: 29093491 PMCID: PMC5665865 DOI: 10.1038/s41598-017-14629-w] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2017] [Accepted: 10/10/2017] [Indexed: 12/25/2022] Open
Abstract
The study aimed to compare the dosimetric parameters to target dose coverage and the critical structures in the treatment planning of helical tomotherapy (TOMO), volumetric-modulated arc therapy (VMAT), and fixed-field intensity-modulated radiotherapy (IMRT) for NSCLC delivering conventionally fractionated radiotherapy. Thirty patients with pathologically confirmed NSCLC were included. Three radiation treatment plans were designed for each patient. All patients received the uniform prescription dose of 60 Gy to the planning target volume. The conformity index (CI), heterogeneity index (HI), and parameters of critical structures were calculated. A significantly superior mean CI was observed in VMAT than in TOMO or IMRT (P = 0.013, 0.001). Mean HI was also better using VAMT or IMRT than TOMO (P = 0.002, 0.003). Mean lung V20 and V30 were significantly reduced by TOMO compared to IMRT (P = 0.019, 0.029). The heart was spared by IMRT compared to TOMO in terms of mean heart dose, V5, V10, and V20 (P < 0.05). In larger tumor, VMAT provided the optimal dose distribution and sparing to heart. Compared to TOMO and IMRT, VMAT achieved better target dose distribution and similar sparing of critical structures. VMAT seemed to be the optimal technique for NSCLC.
Collapse
Affiliation(s)
- Yujin Xu
- Department of Radiation Oncology, The Second Affiliated Hospital of Soochow University, Suzhou, China.,Department of Radiation Oncology, Zhejiang Cancer Hospital, Hangzhou, China
| | - Weiye Deng
- Department of Radiation Oncology, The University of Texas, M. D. Anderson Cancer Center, Houston, USA
| | - Shuangyan Yang
- Department of Radiation Physics, Zhejiang Cancer Hospital, Hangzhou, China
| | - Pu Li
- Department of Radiation Physics, Zhejiang Cancer Hospital, Hangzhou, China
| | - Yue Kong
- Department of Radiation Oncology, Zhejiang Cancer Hospital, Hangzhou, China
| | - Ye Tian
- Department of Radiation Oncology, The Second Affiliated Hospital of Soochow University, Suzhou, China
| | - Zhongxing Liao
- Department of Radiation Oncology, The University of Texas, M. D. Anderson Cancer Center, Houston, USA
| | - Ming Chen
- Department of Radiation Oncology, The Second Affiliated Hospital of Soochow University, Suzhou, China. .,Department of Radiation Oncology, Zhejiang Cancer Hospital, Hangzhou, China.
| |
Collapse
|
33
|
Murai T, Hattori Y, Sugie C, Iwata H, Iwabuchi M, Shibamoto Y. Comparison of multileaf collimator and conventional circular collimator systems in Cyberknife stereotactic radiotherapy. JOURNAL OF RADIATION RESEARCH 2017; 58:693-700. [PMID: 28199669 PMCID: PMC5737677 DOI: 10.1093/jrr/rrw130] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2016] [Indexed: 05/10/2023]
Abstract
Multileaf collimator (MLC) technology has been newly introduced with the Cyberknife system. This study investigated the advantages of this system compared with the conventional circular collimator (CC) system. Dosimetric comparisons of MLC and CC plans were carried out. First, to investigate suitable target sizes for the MLC mode, MLC and CC plans were generated using computed tomography (CT) images from 5 patients for 1, 3, 5 and 7 cm diameter targets. Second, MLC and CC plans were compared in 10 patients, each with liver and prostate targets. For brain targets, doses to the brain could be spared in MLC plans better than in CC plans (P ≤ 0.02). The MLC mode also achieved more uniform dose delivery to the targets. The conformity index in MLC plans was stable, irrespective of the target size (P = 0.5). For patients with liver tumors, the MLC mode achieved higher target coverage than the CC mode (P = 0.04). For prostate tumors, doses to the rectum and the conformity index were lowered in MLC plans compared with in CC plans (P ≤ 0.04). In all target plans, treatment times in MLC plans were shorter than those in CC plans (P < 0.001). The newly introduced MLC technology can reduce treatment time and provide favorable or comparable dose distribution for 1-7 cm targets. In particular, the MLC mode has dosimetric advantage for targets near organs at risk. Therefore, the MLC mode is recommended as the first option in stereotactic body radiotherapy.
Collapse
Affiliation(s)
- Taro Murai
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya 467-8601, Japan
- Corresponding author. Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya 467-8601, Japan. Tel: +81-52-853-8276; Fax: +81-52-852-5244;
| | - Yukiko Hattori
- Department of Radiation Oncology, Nagoya Proton Therapy Center, Nagoya City West Medical Center, Nagoya, Japan
| | - Chikao Sugie
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya 467-8601, Japan
| | - Hiromitsu Iwata
- Department of Radiation Oncology, Nagoya Proton Therapy Center, Nagoya City West Medical Center, Nagoya, Japan
| | | | - Yuta Shibamoto
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya 467-8601, Japan
| |
Collapse
|
34
|
Sood S, Pokhrel D, McClinton C, Lominska C, Badkul R, Jiang H, Wang F. Volumetric-modulated arc therapy (VMAT) for whole brain radiotherapy: not only for hippocampal sparing, but also for reduction of dose to organs at risk. Med Dosim 2017; 42:375-383. [PMID: 28822604 DOI: 10.1016/j.meddos.2017.07.005] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2016] [Revised: 03/08/2017] [Accepted: 07/10/2017] [Indexed: 11/26/2022]
Abstract
A prospective clinical trial, Radiation Therapy Oncology Group (RTOG) 0933, has demonstrated that whole brain radiotherapy (WBRT) using conformal radiation delivery technique with hippocampal avoidance is associated with less memory complications. Further sparing of other organs at risk (OARs) including the scalp, ear canals, cochleae, and parotid glands could be associated with reductions in additional toxicities for patients treated with WBRT. We investigated the feasibility of WBRT using volumetric-modulated arc therapy (VMAT) to spare the hippocampi and the aforementioned OARs. Ten patients previously treated with nonconformal WBRT (NC-WBRT) using opposed lateral beams were retrospectively re-planned using VMAT with hippocampal sparing according to the RTOG 0933 protocol. The OARs (scalp, auditory canals, cochleae, and parotid glands) were considered as dose-constrained structures. VMAT plans were generated for a prescription dose of 30 Gy in 10 fractions. Comparison of the dosimetric parameters achieved by VMAT and NC-WBRT plans was performed using paired t-tests using upper bound p-value of < 0.001. Average beam on time and monitor units (MUs) delivered to the patients on VMAT were compared with those obtained with NC-WBRT. All VMAT plans met RTOG 0933 dosimetric criteria including the dose to hippocampi of 100% of the volume (D100%) of 8.4 ± 0.3 Gy and maximum dose of 15.6 ± 0.4 Gy, respectively. A statistically significant dose reduction (p < 0.001) to all OARs was achieved. The mean and maximum scalp doses were reduced by an average of 9 Gy (32%) and 2 Gy (6%), respectively. The mean and maximum doses to the auditory canals were reduced from 29.5 ± 0.5 Gy and 31.0 ± 0.4 Gy with NC-WBRT, to 21.8 ± 1.6 Gy (26%) and 27.4 ± 1.4 Gy (12%) with VMAT. VMAT also reduced mean and maximum doses to the cochlea by an average of 4 Gy (13%) and 2 Gy (6%), respectively. The parotid glands mean and maximum doses with VMAT were 4.4 ± 1.9 Gy and 15.7 ± 5.0 Gy, compared to 12.8 ± 4.9 Gy and 30.6 ± 0.5 Gy with NC-WBRT, respectively. The average dose reduction of mean and maximum of parotid glands from VMAT were 65% and 50%, respectively. The average beam on time and MUs were 2.3minutes and 719 on VMAT, and 0.7 minutes and 350 on NC-WBRT. This study demonstrated the feasibility of WBRT using VMAT to not only spare the hippocampi, but also significantly reduce dose to OARs. These advantages of VMAT could potentially decrease the toxicities associated with NC-WBRT and improve patients' quality of life, especially for patients with favorable prognosis receiving WBRT or patients receiving prophylactic cranial irradiation (PCI).
Collapse
Affiliation(s)
- Sumit Sood
- Department of Radiation Oncology, The University of Kansas Cancer Center, Kansas City, KS, USA.
| | - Damodar Pokhrel
- Department of Radiation Oncology, The University of Kansas Cancer Center, Kansas City, KS, USA
| | - Christopher McClinton
- Department of Radiation Oncology, The University of Kansas Cancer Center, Kansas City, KS, USA
| | - Christopher Lominska
- Department of Radiation Oncology, The University of Kansas Cancer Center, Kansas City, KS, USA
| | - Rajeev Badkul
- Department of Radiation Oncology, The University of Kansas Cancer Center, Kansas City, KS, USA
| | - Hongyu Jiang
- Department of Radiation Oncology, The University of Kansas Cancer Center, Kansas City, KS, USA
| | - Fen Wang
- Department of Radiation Oncology, The University of Kansas Cancer Center, Kansas City, KS, USA
| |
Collapse
|
35
|
Kai Y, Toya R, Saito T, Kuraoka A, Shimohigashi Y, Nakaguchi Y, Maruyama M, Murakami R, Yamashita Y, Oya N. Plan quality and delivery time comparisons between volumetric modulated arc therapy and intensity modulated radiation therapy for scalp angiosarcoma: A planning study. J Med Radiat Sci 2017; 65:39-47. [PMID: 28755441 PMCID: PMC5846018 DOI: 10.1002/jmrs.239] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2016] [Revised: 05/08/2017] [Accepted: 06/30/2017] [Indexed: 12/25/2022] Open
Abstract
Introduction Due to its spherical surface, scalp angiosarcoma requires careful consideration for radiation therapy planning and dose delivery. Herein, we investigated whether volumetric modulated arc therapy (VMAT) is superior to intensity modulated radiation therapy (IMRT) in terms of the plan quality and delivery time. Methods Three different coplanar treatment plans were created for four patients, comprising a two‐arc VMAT plan as well as 5‐field and 9‐field IMRT plans with 6 MV beams. The X‐ray Voxel Monte Carlo algorithm was employed for dose calculation. A radiation therapy dose of 60 Gy was prescribed to the planning target volume (PTV) in 30 fractions. The homogeneity indexes (HIs) and conformity indexes (CIs) of the PTV, organs at risk (OARs) doses and delivery times were calculated and compared. Results For the VMAT, 5‐field and 9‐field IMRT plans, the mean HIs were 0.14, 0.16 and 0.15; CIs100% were 0.63, 0.61 and 0.64; CIs98% were 0.72, 0.66 and 0.70 and CIs95% were 0.74, 0.67 and 0.71 respectively. All mean dose parameters of the VMAT and 9‐field IMRT plans for the brain were equal to or lower than those of the 5‐field IMRT plan. For the 5‐field IMRT plan, the dose constraints for the left lens were not satisfied in two patients. The mean delivery times were 3.3, 11.1 and 14.7 min for the VMAT, 5‐field and 9‐field IMRT plans respectively. Conclusion The VMAT plan quality is comparable to that of 9‐field IMRT, with a reduced delivery time. Therefore, VMAT represents a valuable, sophisticated irradiation technique for treating scalp angiosarcoma.
Collapse
Affiliation(s)
- Yudai Kai
- Department of Radiological Technology, Kumamoto University Hospital, Kumamoto, Japan
| | - Ryo Toya
- Department of Radiation Oncology, Kumamoto University Hospital, Kumamoto, Japan.,Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| | - Tetsuo Saito
- Department of Radiation Oncology, Kumamoto University Hospital, Kumamoto, Japan
| | - Akiko Kuraoka
- Department of Radiological Technology, Kumamoto University Hospital, Kumamoto, Japan
| | | | - Yuji Nakaguchi
- Department of Radiological Technology, Kumamoto University Hospital, Kumamoto, Japan
| | - Masato Maruyama
- Department of Radiological Technology, Kumamoto University Hospital, Kumamoto, Japan
| | - Ryuji Murakami
- Department of Medical Imaging, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan
| | - Yasuyuki Yamashita
- Department of Diagnostic Radiology, Kumamoto University Hospital, Kumamoto, Japan
| | - Natsuo Oya
- Department of Radiation Oncology, Kumamoto University Hospital, Kumamoto, Japan
| |
Collapse
|
36
|
Macchia G, Deodato F, Cilla S, Cammelli S, Guido A, Ferioli M, Siepe G, Valentini V, Morganti AG, Ferrandina G. Volumetric modulated arc therapy for treatment of solid tumors: current insights. Onco Targets Ther 2017; 10:3755-3772. [PMID: 28794640 PMCID: PMC5538686 DOI: 10.2147/ott.s113119] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023] Open
Abstract
Aim This article discusses the current use of volumetric modulated arc therapy (VMAT) techniques in clinical practice and reviews the available data from clinical outcome studies in different clinical settings. An overview of available literature about clinical outcomes with VMAT stereotactic/radiosurgical treatment is also reported. Materials and methods All published manuscripts reporting the use of VMAT in a clinical setting from 2009 to November 2016 were identified. The search was carried out in December 2016 using the National Library of Medicine (PubMed/Medline). The following words were searched: “volumetric arc therapy”[All Fields] OR “vmat”[All Fields] OR “rapidarc”[All Fields], AND “radiotherapy”[All Fields] AND “Clinical Trial”[All Fields]. Results Overall, 37 studies (21 prospective and 16 retrospective) fulfilling inclusion criteria and thus included in the review evaluated 2,029 patients treated with VMAT; of these patients, ~30.8% had genitourinary (GU) tumors (81% prostate, 19% endometrial), 26.2% head-and-neck cancer (H&NC), 13.9% oligometastases, 11.2% had anorectal cancer, 10.6% thoracic neoplasms (81% breast, 19% lung), and 7.0% brain metastases (BMs). Six different clinical scenarios for VMAT use were identified: 1) BMs, 2) H&NC, 3) thoracic neoplasms, 4) GU cancer, 5) anorectal tumor, and 6) stereotactic body radiation therapy (SBRT) performed by VMAT technique in the oligometastatic patient setting. Conclusion The literature addressing the clinical appropriateness of VMAT is scarce. Current literature suggests that VMAT, especially when used as simultaneous integrated boost or SBRT strategy, is an effective safe modality for all cancer types.
Collapse
Affiliation(s)
| | | | - Savino Cilla
- Medical Physics Unit, "Giovanni Paolo II" Foundation, Catholic University of the Sacred Heart, Campobasso
| | - Silvia Cammelli
- Radiation Oncology Unit, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, S. Orsola-Malpighi Hospital, Bologna
| | - Alessandra Guido
- Radiation Oncology Unit, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, S. Orsola-Malpighi Hospital, Bologna
| | - Martina Ferioli
- Radiation Oncology Unit, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, S. Orsola-Malpighi Hospital, Bologna
| | - Giambattista Siepe
- Radiation Oncology Unit, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, S. Orsola-Malpighi Hospital, Bologna
| | - Vincenzo Valentini
- Department of Radiation Oncology, Catholic University of the Sacred Heart, Rome
| | - Alessio Giuseppe Morganti
- Radiation Oncology Unit, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, S. Orsola-Malpighi Hospital, Bologna
| | - Gabriella Ferrandina
- Department of Obstetrics and Gynecology, Catholic University of the Sacred Heart, Rome.,Department of Health Sciences and Medicine, University of Molise, Campobasso, Italy
| |
Collapse
|
37
|
Zwan BJ, Barnes MP, Hindmarsh J, Lim SB, Lovelock DM, Fuangrod T, O'Connor DJ, Keall PJ, Greer PB. Commissioning and quality assurance for VMAT delivery systems: An efficient time-resolved system using real-time EPID imaging. Med Phys 2017; 44:3909-3922. [PMID: 28564208 DOI: 10.1002/mp.12387] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2017] [Revised: 05/22/2017] [Accepted: 05/22/2017] [Indexed: 11/07/2022] Open
Abstract
PURPOSE An ideal commissioning and quality assurance (QA) program for Volumetric Modulated Arc Therapy (VMAT) delivery systems should assess the performance of each individual dynamic component as a function of gantry angle. Procedures within such a program should also be time-efficient, independent of the delivery system and be sensitive to all types of errors. The purpose of this work is to develop a system for automated time-resolved commissioning and QA of VMAT control systems which meets these criteria. METHODS The procedures developed within this work rely solely on images obtained, using an electronic portal imaging device (EPID) without the presence of a phantom. During the delivery of specially designed VMAT test plans, EPID frames were acquired at 9.5 Hz, using a frame grabber. The set of test plans was developed to individually assess the performance of the dose delivery and multileaf collimator (MLC) control systems under varying levels of delivery complexities. An in-house software tool was developed to automatically extract features from the EPID images and evaluate the following characteristics as a function of gantry angle: dose delivery accuracy, dose rate constancy, beam profile constancy, gantry speed constancy, dynamic MLC positioning accuracy, MLC speed and acceleration constancy, and synchronization between gantry angle, MLC positioning and dose rate. Machine log files were also acquired during each delivery and subsequently compared to information extracted from EPID image frames. RESULTS The largest difference between measured and planned dose at any gantry angle was 0.8% which correlated with rapid changes in dose rate and gantry speed. For all other test plans, the dose delivered was within 0.25% of the planned dose for all gantry angles. Profile constancy was not found to vary with gantry angle for tests where gantry speed and dose rate were constant, however, for tests with varying dose rate and gantry speed, segments with lower dose rate and higher gantry speed exhibited less profile stability. MLC positional accuracy was not observed to be dependent on the degree of interdigitation. MLC speed was measured for each individual leaf and slower leaf speeds were shown to be compensated for by lower dose rates. The test procedures were found to be sensitive to 1 mm systematic MLC errors, 1 mm random MLC errors, 0.4 mm MLC gap errors and synchronization errors between the MLC, dose rate and gantry angle controls systems of 1°. In general, parameters measured by both EPID and log files agreed with the plan, however, a greater average departure from the plan was evidenced by the EPID measurements. CONCLUSION QA test plans and analysis methods have been developed to assess the performance of each dynamic component of VMAT deliveries individually and as a function of gantry angle. This methodology relies solely on time-resolved EPID imaging without the presence of a phantom and has been shown to be sensitive to a range of delivery errors. The procedures developed in this work are both comprehensive and time-efficient and can be used for streamlined commissioning and QA of VMAT delivery systems.
Collapse
Affiliation(s)
- Benjamin J Zwan
- Central Coast Cancer Centre, Gosford Hospital, Gosford, NSW, 2250, Australia
- School of Mathematical and Physical Sciences, University of Newcastle, Newcastle, NSW, 2308, Australia
| | - Michael P Barnes
- Department of Radiation Oncology, Calvary Mater Hospital, Newcastle, NSW, 2298, Australia
- School of Medical Radiation Sciences, University of Newcastle, Newcastle, NSW, 2308, Australia
| | - Jonathan Hindmarsh
- Central Coast Cancer Centre, Gosford Hospital, Gosford, NSW, 2250, Australia
| | - Seng B Lim
- Department of Medical Physics, Memorial Sloan-Kettering Cancer Centre, New York, NY, 10065, USA
| | - Dale M Lovelock
- Department of Medical Physics, Memorial Sloan-Kettering Cancer Centre, New York, NY, 10065, USA
| | - Todsaporn Fuangrod
- Department of Radiation Oncology, Calvary Mater Hospital, Newcastle, NSW, 2298, Australia
| | - Daryl J O'Connor
- School of Mathematical and Physical Sciences, University of Newcastle, Newcastle, NSW, 2308, Australia
| | - Paul J Keall
- Radiation Physics Laboratory, Sydney Medical School, University of Sydney, Sydney, NSW, 2006, Australia
| | - Peter B Greer
- School of Mathematical and Physical Sciences, University of Newcastle, Newcastle, NSW, 2308, Australia
- Department of Radiation Oncology, Calvary Mater Hospital, Newcastle, NSW, 2298, Australia
| |
Collapse
|
38
|
Xi M, Lin SH. Recent advances in intensity modulated radiotherapy and proton therapy for esophageal cancer. Expert Rev Anticancer Ther 2017; 17:635-646. [PMID: 28503964 DOI: 10.1080/14737140.2017.1331130] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
INTRODUCTION Radiotherapy is an important component of the standard of care for esophageal cancer. In the past decades, significant improvements in the planning and delivery of radiation techniques have led to better dose conformity to the target volume and improved normal tissue sparing. Areas covered: This review focuses on the advances in radiotherapy techniques and summarizes the availably dosimetric and clinical outcomes of intensity-modulated radiation therapy (IMRT), volumetric modulated arc therapy, proton therapy, and four-dimensional radiotherapy for esophageal cancer, and discusses the challenges and future development of proton therapy. Expert commentary: Although three-dimensional conformal radiotherapy is the standard radiotherapy technique in esophageal cancer, the retrospectively comparative studies strongly suggest that the dosimetric advantage of IMRT over three-dimensional conformal radiotherapy can translate into improved clinical outcomes, despite the lack of prospective randomized evidence. As a novel form of conventional IMRT technique, volumetric modulated arc therapy can produce equivalent or superior dosimetric quality with significantly higher treatment efficiency in esophageal cancer. Compared with photon therapy, proton therapy has the potential to achieve further clinical improvement due to their physical properties; however, prospective clinical data, long-term results, and cost-effectiveness are needed.
Collapse
Affiliation(s)
- Mian Xi
- a Department of Radiation Oncology, Cancer Center , Sun Yat-Sen University, State Key Laboratory of Oncology in South China, Collaborative Innovation Centre for Cancer Medicine , Guangzhou , Guangdong , China
| | - Steven H Lin
- b Department of Radiation Oncology , The University of Texas MD Anderson Cancer Center , Houston , TX , USA
| |
Collapse
|
39
|
Liu W, Patel SH, Harrington DP, Hu Y, Ding X, Shen J, Halyard MY, Schild SE, Wong WW, Ezzell GE, Bues M. Exploratory study of the association of volumetric modulated arc therapy (VMAT) plan robustness with local failure in head and neck cancer. J Appl Clin Med Phys 2017; 18:76-83. [PMID: 28503916 PMCID: PMC5500391 DOI: 10.1002/acm2.12099] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2016] [Revised: 03/02/2016] [Accepted: 03/30/2017] [Indexed: 12/25/2022] Open
Abstract
This work is to show which is more relevant to cause local failures (LFs) due to patient setup uncertainty between the planning target volume (PTV) underdosage and the potential target underdosage subject to patient setup uncertainties in head and neck (H&N) cancer treated with volumetric‐modulated arc therapy (VMAT). Thirteen LFs in 10 H&N patients treated by VMAT were analyzed. Measures have been taken to minimize the chances of insufficient target delineation for these patients and the patients were clinically determined to have LF based on the PET/CT scan results by an experienced radiologist and then reviewed by a second experienced radiation oncologist. Two methods were used to identify the possible locations of LF due to underdosage: (a) examining the standard VMAT plan, in which the underdosed volume in the nominal dose distribution (UVN) was generated by subtracting the volumes receiving the prescription doses from PTVs, and (b) plan robustness analysis, in which in addition to the nominal dose distribution, six perturbed dose distributions were created by translating the CT iso‐center in three cardinal directions by the PTV margin. The coldest dose distribution was represented by the minimum of the seven doses in each voxel. The underdosed volume in the coldest dose distribution (UVC) was generated by subtracting the volumes receiving the prescription doses in the coldest dose distribution from the volumes receiving the prescription doses in the nominal dose distribution. UVN and UVC were subsequently examined for spatial association with the locations of LF. The association was tested using the binominal distribution and the Fisher's exact test of independence. We found that of 13 LFs, 11 were associated with UVCs (P = 0.011), while three were associated with UVNs (P = 0.99). We concluded that the possible target underdosage due to patient setup uncertainties appeared to be a more relevant factor associated with LF in VMAT for H&N cancer than the compromised PTV coverage at least for the patients included in this study.
Collapse
Affiliation(s)
- Wei Liu
- Department of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, 85054, USA
| | - Samir H Patel
- Department of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, 85054, USA
| | | | - Yanle Hu
- Department of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, 85054, USA
| | - Xiaoning Ding
- Department of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, 85054, USA
| | - Jiajian Shen
- Department of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, 85054, USA
| | - Michele Y Halyard
- Department of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, 85054, USA
| | - Steven E Schild
- Department of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, 85054, USA
| | - William W Wong
- Department of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, 85054, USA
| | - Gary E Ezzell
- Department of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, 85054, USA
| | - Martin Bues
- Department of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, 85054, USA
| |
Collapse
|
40
|
Sothmann T, Gauer T, Werner R. 4D dose simulation in volumetric arc therapy: Accuracy and affecting parameters. PLoS One 2017; 12:e0172810. [PMID: 28231337 PMCID: PMC5322962 DOI: 10.1371/journal.pone.0172810] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2016] [Accepted: 02/09/2017] [Indexed: 12/14/2022] Open
Abstract
Radiotherapy of lung and liver lesions has changed from normofractioned 3D-CRT to stereotactic treatment in a single or few fractions, often employing volumetric arc therapy (VMAT)-based techniques. Potential unintended interference of respiratory target motion and dynamically changing beam parameters during VMAT dose delivery motivates establishing 4D quality assurance (4D QA) procedures to assess appropriateness of generated VMAT treatment plans when taking into account patient-specific motion characteristics. Current approaches are motion phantom-based 4D QA and image-based 4D VMAT dose simulation. Whereas phantom-based 4D QA is usually restricted to a small number of measurements, the computational approaches allow simulating many motion scenarios. However, 4D VMAT dose simulation depends on various input parameters, influencing estimated doses along with mitigating simulation reliability. Thus, aiming at routine use of simulation-based 4D VMAT QA, the impact of such parameters as well as the overall accuracy of the 4D VMAT dose simulation has to be studied in detail–which is the topic of the present work. In detail, we introduce the principles of 4D VMAT dose simulation, identify influencing parameters and assess their impact on 4D dose simulation accuracy by comparison of simulated motion-affected dose distributions to corresponding dosimetric motion phantom measurements. Exploiting an ITV-based treatment planning approach, VMAT treatment plans were generated for a motion phantom and different motion scenarios (sinusoidal motion of different period/direction; regular/irregular motion). 4D VMAT dose simulation results and dose measurements were compared by local 3% / 3 mm γ-evaluation, with the measured dose distributions serving as ground truth. Overall γ-passing rates of simulations and dynamic measurements ranged from 97% to 100% (mean across all motion scenarios: 98% ± 1%); corresponding values for comparison of different day repeat measurements were between 98% and 100%. Parameters of major influence on 4D VMAT dose simulation accuracy were the degree of temporal discretization of the dose delivery process (the higher, the better) and correct alignment of the assumed breathing phases at the beginning of the dose measurements and simulations. Given the high γ-passing rates between simulated motion-affected doses and dynamic measurements, we consider the simulations to provide a reliable basis for assessment of VMAT motion effects that–in the sense of 4D QA of VMAT treatment plans–allows to verify target coverage in hypofractioned VMAT-based radiotherapy of moving targets. Remaining differences between measurements and simulations motivate, however, further detailed studies.
Collapse
Affiliation(s)
- Thilo Sothmann
- Department of Computational Neuroscience, University Medical Center Hamburg-Eppendorf, Hamburg, Hamburg, Germany
- * E-mail:
| | - Tobias Gauer
- Department of Radiotherapy and Radio-Oncology, University Medical Center Hamburg-Eppendorf, Hamburg, Hamburg, Germany
| | - René Werner
- Department of Computational Neuroscience, University Medical Center Hamburg-Eppendorf, Hamburg, Hamburg, Germany
| |
Collapse
|
41
|
Yang B, Wong WKR, Geng H, Lam WW, Ho YW, Kwok WM, Cheung KY, Yu SK. Filmless methods for quality assurance of Tomotherapy using ArcCHECK. Med Phys 2017; 44:7-16. [PMID: 28044341 DOI: 10.1002/mp.12009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2016] [Revised: 10/15/2016] [Accepted: 11/08/2016] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Tomotherapy delivers an intensity-modulated radiation therapy (IMRT) treatment by the synchronization of gantry rotation, multileaf collimator (MLC), and couch movement. This dynamic nature makes the quality assurance (QA) important and challenging. The purpose of this study is to develop some methodologies using an ArcCHECK for accurate QA measurements of the gantry angle and speed, MLC synchronization and leaf open time, couch translation per gantry rotation, couch speed and uniformity, and constancy of longitudinal beam profile for a Tomotherapy unit. METHODS Four test plans recommended by AAPM Task Group 148 (TG148) and the manufacturer were chosen for this study. Helical and static star shot tests are used for checking the leaves opened at the expected gantry angles. Another helical test is to verify the couch traveled the expected distance per gantry rotation. The final test is for checking the couch speed constancy with a static gantry. ArcCHECK can record the detector signal every 50 ms as a movie file, and has a virtual inclinometer for gantry angle measurement. These features made the measurement of gantry angle and speed, MLC synchronization and leaf open time, and longitudinal beam profile possible. A shaping parameter was defined for facilitating the location of the beam center during the plan delivery, which was thereafter used to calculate the couch translation per gantry rotation and couch speed. The full width at half maximum (FWHM) was calculated for each measured longitudinal beam profile and then used to evaluate the couch speed uniformity. Furthermore, a mean longitudinal profile was obtained for constancy check of field width. The machine trajectory log data were also collected for comparison. Inhouse programs were developed in MATLAB to process both the ArcCHECK and machine log data. RESULTS The deviation of our measurement results from the log data for gantry angle was calculated to be less than 0.4°. The percentage differences between measured and planned leaf open time were found to be within 0.5% in all the tests. Our results showed mean values of MLC synchronization of 0.982, 0.983, and 0.995 at static gantry angle 0°, 45°, and 135°, respectively. The mean value of measured couch translation and couch speed by ArcCHECK had less than 0.1% deviation from the planned values. The variation in the value of FWHM suggested the couch speed uniformity was better than 1%. The mean of measured longitudinal profiles was suitable for constancy check of field width. CONCLUSION Precise and efficient methods for measuring the gantry angle and speed, leaf open time, couch translation per gantry rotation, couch speed and uniformity, and constancy of longitudinal beam profile of Tomotherapy using ArcCHECK have been developed and proven to be accurate compared with machine log data. Estimation of the Tomotherapy binary MLC leaf open time is proven to be precise enough to verify the leaf open time as small as 277.8 ms. Our method also makes the observation and quantification of the synchronization of leaves possible.
Collapse
Affiliation(s)
- B Yang
- Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong
| | - W K R Wong
- Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong
| | - H Geng
- Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong
| | - W W Lam
- Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong
| | - Y W Ho
- Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong
| | - W M Kwok
- Biomedical Engineering Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong
| | - K Y Cheung
- Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong
| | - S K Yu
- Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, 2 Village Road, Happy Valley, Hong Kong
| |
Collapse
|
42
|
Pokhrel D, Sood S, McClinton C, Shen X, Badkul R, Jiang H, Mallory M, Mitchell M, Wang F, Lominska C. On the use of volumetric-modulated arc therapy for single-fraction thoracic vertebral metastases stereotactic body radiosurgery. Med Dosim 2017; 42:69-75. [DOI: 10.1016/j.meddos.2016.12.003] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2016] [Revised: 11/25/2016] [Accepted: 12/12/2016] [Indexed: 12/31/2022]
|
43
|
Al2O3:C optically stimulated luminescence droplets: Characterization and applications in medical beams. RADIAT MEAS 2016. [DOI: 10.1016/j.radmeas.2016.09.003] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
44
|
Jacobs M, Boersma L, Dekker A, Bosmans G, van Merode F, Verhaegen F, de Ruysscher D, Swart R, Kengen C, Lambin P. What is the degree of innovation routinely implemented in Dutch radiotherapy centres? A multicentre cross-sectional study. Br J Radiol 2016; 89:20160601. [PMID: 27660890 PMCID: PMC5124852 DOI: 10.1259/bjr.20160601] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Objective: To study the implementation of innovation activities in Dutch radiotherapy (RT) centres in a broad sense (product, technological, market and organizational innovations). Methods: A descriptive cross-sectional study was conducted in 15 Dutch RT centres. A list of innovations implemented from 2011 to 2013 was drawn up for each centre using semi-structured interviews. These innovations were classified into innovation categories according to previously defined innovation indicators. Where applicable, each innovation was rated by each centre on the effort required to implement it and on its expected effects, to get an impression of how far reaching and radical the innovations were and to be able to compare the number of innovations between centres. Results: The participating RT centres in the Netherlands implemented 12 innovations per year on average (range 5–25); this number was not significantly different for academic (n = 13) or non-academic centres (n = 10). Several centres were dealing with the same innovations at the same time. The average required effort and expected output did not differ significantly between product, technological and organizational innovation or between academic and non-academic centres. Conclusion: The number of innovations observed per centre varied across a large range, with a large overlap in terms of the type of innovations that were implemented. Registering innovations using the innovation indicators applied in our study would make it possible to improve collaboration between centres, e.g. with common training modules, to avoid duplication of work. Advances in knowledge: This study is the first of its kind investigating innovation implementation in RT in a broad sense.
Collapse
Affiliation(s)
- Maria Jacobs
- 1 Department of Radiation Oncology, MAASTRO clinic, Maastricht, Netherlands.,2 CAPHRI School for Public Health and Primary Care, Maastricht University Medical Centre+, Maastricht, Netherlands
| | - Liesbeth Boersma
- 1 Department of Radiation Oncology, MAASTRO clinic, Maastricht, Netherlands.,3 GROW School for Oncology and Developmental Biology, Maastricht University, Medical Centre+, Maastricht, Netherlands
| | - Andre Dekker
- 1 Department of Radiation Oncology, MAASTRO clinic, Maastricht, Netherlands.,3 GROW School for Oncology and Developmental Biology, Maastricht University, Medical Centre+, Maastricht, Netherlands
| | - Geert Bosmans
- 1 Department of Radiation Oncology, MAASTRO clinic, Maastricht, Netherlands.,3 GROW School for Oncology and Developmental Biology, Maastricht University, Medical Centre+, Maastricht, Netherlands
| | - Frits van Merode
- 4 Executive Board, Maastricht University Medical Centre+, Maastricht, Netherlands
| | - Frank Verhaegen
- 1 Department of Radiation Oncology, MAASTRO clinic, Maastricht, Netherlands.,3 GROW School for Oncology and Developmental Biology, Maastricht University, Medical Centre+, Maastricht, Netherlands
| | - Dirk de Ruysscher
- 1 Department of Radiation Oncology, MAASTRO clinic, Maastricht, Netherlands.,3 GROW School for Oncology and Developmental Biology, Maastricht University, Medical Centre+, Maastricht, Netherlands
| | - Rachelle Swart
- 1 Department of Radiation Oncology, MAASTRO clinic, Maastricht, Netherlands.,3 GROW School for Oncology and Developmental Biology, Maastricht University, Medical Centre+, Maastricht, Netherlands
| | - Cindy Kengen
- 1 Department of Radiation Oncology, MAASTRO clinic, Maastricht, Netherlands.,3 GROW School for Oncology and Developmental Biology, Maastricht University, Medical Centre+, Maastricht, Netherlands
| | - Philippe Lambin
- 1 Department of Radiation Oncology, MAASTRO clinic, Maastricht, Netherlands.,3 GROW School for Oncology and Developmental Biology, Maastricht University, Medical Centre+, Maastricht, Netherlands
| |
Collapse
|
45
|
Sonier M, Chu W, Lalani N, Erler D, Cheung P, Korol R. Implementation of a volumetric modulated arc therapy treatment planning solution for kidney and adrenal stereotactic body radiation therapy. Med Dosim 2016; 41:323-328. [PMID: 27745995 DOI: 10.1016/j.meddos.2016.09.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2016] [Revised: 07/05/2016] [Accepted: 09/07/2016] [Indexed: 12/31/2022]
Abstract
To develop a volumetric modulated arc therapy (VMAT) treatment planning solution in the treatment of primary renal cell carcinoma and oligometastatic adrenal lesions with stereotactic body radiation therapy. Single-arc VMAT plans (n = 5) were compared with clinically delivered step-and-shoot intensity-modulated radiotherapy (IMRT) with planning target volume coverage normalized between techniques. Target volume conformity, organ-at-risk (OAR) dose, treatment time, and monitor units were compared. A VMAT planning solution, created from a combination of arc settings and optimization constraints, auto-generated treatment plans in a single optimization. The treatment planning solution was evaluated on 15 consecutive patients receiving kidney and adrenal stereotactic body radiation therapy. Treatment time was reduced from 13.0 ± 2.6 to 4.0 ± 0.9 minutes for IMRT and VMAT, respectively. The VMAT planning solution generated treatment plans with increased target homogeneity, improved 95% conformity index, and a reduced maximum point dose to nearby OARs but with increased intermediate dose to distant OARs. The conformity of the 95% isodose improved from 1.32 ± 0.39 to 1.12 ± 0.05 for IMRT and VMAT treatment plans, respectively. Evaluation of the planning solution showed clinically acceptable dose distributions for 13 of 15 cases with tight conformity of the prescription isodose to the planning target volume of 1.07 ± 0.04, delivering minimal dose to OARs. The introduction of a stereotactic body radiation therapy VMAT treatment planning solution improves the efficiency of planning and delivery time, producing treatment plans of comparable or superior quality to IMRT in the case of primary renal cell carcinoma and oligometastatic adrenal lesions.
Collapse
Affiliation(s)
- Marcus Sonier
- Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, ON, Canada.
| | - William Chu
- Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, ON, Canada; Department of Radiation Oncology, University of Toronto, Toronto, ON, Canada
| | - Nafisha Lalani
- Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, ON, Canada
| | - Darby Erler
- Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, ON, Canada
| | - Patrick Cheung
- Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, ON, Canada; Department of Radiation Oncology, University of Toronto, Toronto, ON, Canada
| | - Renee Korol
- Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, ON, Canada
| |
Collapse
|
46
|
Silva SR, Surucu M, Steber J, Harkenrider MM, Choi M. Clinical Application of a Hybrid RapidArc Radiotherapy Technique for Locally Advanced Lung Cancer. Technol Cancer Res Treat 2016; 16:224-230. [PMID: 27680023 DOI: 10.1177/1533034616670273] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
OBJECTIVE Radiation treatment planning for locally advanced lung cancer can be technically challenging, as delivery of ≥60 Gy to large volumes with concurrent chemotherapy is often associated with significant risk of normal tissue toxicity. We clinically implemented a novel hybrid RapidArc technique in patients with lung cancer and compared these plans with 3-dimensional conformal radiotherapy and RapidArc-only plans. MATERIALS/METHODS Hybrid RapidArc was used to treat 11 patients with locally advanced lung cancer having bulky mediastinal adenopathy. All 11 patients received concurrent chemotherapy. All underwent a 4-dimensional computed tomography planning scan. Hybrid RapidArc plans concurrently combined static (60%) and RapidArc (40%) beams. All cases were replanned using 3- to 5-field 3-dimensional conformal radiotherapy and RapidArc technique as controls. RESULTS Significant reductions in dose were observed in hybrid RapidArc plans compared to 3-dimensional conformal radiotherapy plans for total lung V20 and mean (-2% and -0.6 Gy); contralateral lung mean (-2.92 Gy); and esophagus V60 and mean (-16.0% and -2.2 Gy; all P < .05). Contralateral lung doses were significantly lower for hybrid RapidArc plans compared to RapidArc-only plans (all P < .05). Compared to 3-dimensional conformal radiotherapy, heart V60 and mean dose were significantly improved with hybrid RapidArc (3% vs 5%, P = .04 and 16.32 Gy vs 16.65 Gy, P = .03). However, heart V40 and V45 and maximum spinal cord dose were significantly lower with RapidArc plans compared to hybrid RapidArc plans. Conformity and homogeneity were significantly better with hybrid RapidArc plans compared to 3-dimensional conformal radiotherapy plans ( P < .05). Treatment was well tolerated, with no grade 3+ toxicities. CONCLUSION To our knowledge, this is the first report on the clinical application of hybrid RapidArc in patients with locally advanced lung cancer. Hybrid RapidArc permitted safe delivery of 60 to 66 Gy to large lung tumors with concurrent chemotherapy and demonstrated advantages for reduction in low-dose lung volumes, esophageal dose, and mean heart dose.
Collapse
Affiliation(s)
- Scott R Silva
- 1 Department of Radiation Oncology, Stritch School of Medicine, Loyola University Medical Center, Maywood, IL, USA
| | - Murat Surucu
- 1 Department of Radiation Oncology, Stritch School of Medicine, Loyola University Medical Center, Maywood, IL, USA
| | - Jennifer Steber
- 1 Department of Radiation Oncology, Stritch School of Medicine, Loyola University Medical Center, Maywood, IL, USA
| | - Matthew M Harkenrider
- 1 Department of Radiation Oncology, Stritch School of Medicine, Loyola University Medical Center, Maywood, IL, USA
| | - Mehee Choi
- 1 Department of Radiation Oncology, Stritch School of Medicine, Loyola University Medical Center, Maywood, IL, USA
| |
Collapse
|
47
|
Yuan J, Lei M, Yang Z, Fu J, Huo L, Hong J. Dosimetric comparison between intensity-modulated radiotherapy and RapidArc with single arc and dual arc for malignant glioma involving the parietal lobe. Mol Clin Oncol 2016; 5:181-188. [PMID: 27330795 DOI: 10.3892/mco.2016.872] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2015] [Accepted: 04/11/2016] [Indexed: 11/05/2022] Open
Abstract
The aim of the present study was to evaluate the difference in treatment plan quality, monitor units (MUs) per fraction and dosimetric parameters between IMRT (intensity-modulated radiotherapy) and RapidArc with single arc (RA1) and dual arc (RA2) for malignant glioma involving the parietal lobe. Treatment plans for IMRT and RA1 and RA2 were prepared for 10 patients with malignant gliomas involving the parietal lobe. The Wilcoxon matched-pair signed-rank test was used to compare the plan quality, monitor units and dosimetric parameters between IMRT and RA1 and RA2 through dose-volume histograms. Dnear-max (D2%) to the left lens, right lens and left optical nerve in RA1 were less compared with those in IMRT; D2% to the right lens and right optic nerve in RA2 were less compared with those in IMRT. D2% to the optic chiasma in RA2 was small compared with that in RA1. The median dose (D50%) to the right lens and right optic nerve in RA1 and RA2 was less compared with the identical parameters in IMRT, and D50% to the brain stem in RA2 was less compared with that in RA1. The volume receiving at least 45 Gy (V45) or V50 in normal brain tissue (whole brain minus the planning target volume 2; B-P) in RA1 was less compared with that in IMRT. V30, V35, V40, V45, or V50 in B-P in RA2 was less compared with that in IMRT. The MUs per fraction in RA1 and RA2 were significantly less compared with those in IMRT. All differences with a P-value<0.05 were considered to be significantly different. In conclusion, RA1 and RA2 markedly reduced the MUs per fraction, and spared partial organs at risk and B-P compared with IMRT.
Collapse
Affiliation(s)
- Jun Yuan
- Department of Radiation Oncology, Xiangya Hospital, Central South University, Changsha, Hunan 410008, P.R. China
| | - Mingjun Lei
- Department of Radiation Oncology, Xiangya Hospital, Central South University, Changsha, Hunan 410008, P.R. China
| | - Zhen Yang
- Department of Radiation Oncology, Xiangya Hospital, Central South University, Changsha, Hunan 410008, P.R. China
| | - Jun Fu
- Department of Radiation Oncology, Xiangya Hospital, Central South University, Changsha, Hunan 410008, P.R. China
| | - Lei Huo
- The Institute of Skull Base Surgery and Neuro-Oncology at Hunan, Xiangya Hospital, Central South University, Changsha, Hunan 410008, P.R. China
| | - Jidong Hong
- Department of Radiation Oncology, Xiangya Hospital, Central South University, Changsha, Hunan 410008, P.R. China
| |
Collapse
|
48
|
Zhao LR, Zhou YB, Sun JG. Comparison of plan optimization for single and dual volumetric-modulated arc therapy versus intensity-modulated radiation therapy during post-mastectomy regional irradiation. Oncol Lett 2016; 11:3389-3394. [PMID: 27123122 DOI: 10.3892/ol.2016.4376] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2014] [Accepted: 07/28/2015] [Indexed: 11/06/2022] Open
Abstract
The aim of the present study was to investigate volumetric-modulated arc therapy (VMAT) with single arc (1ARC) and dual arc (2ARC), and intensity-modulated radiation therapy (IMRT), and to evaluate the quality and delivery efficiency of post-mastectomy regional irradiation. A total of 24 female patients who required post-mastectomy regional irradiation were enrolled into the current study, and 1ARC, 2ARC and IMRT plans were designed for each individual patient. The quality of these plans was evaluated by calculating the homogeneity index (HI), conformity index (CI) and specific volume dose to the ipsilateral lung, double lungs, contralateral breast, heart and spinal cord. For the delivery efficiency of these plans, the total treatment time (TTT) and the number of monitor units (MUs) were evaluated. The 1ARC and 2ARC VMAT plans exhibited significantly better HIs and CIs than IMRT. For dose-volume histogram analysis, 1ARC and 2ARC VMAT spared a more specific volume dose to the ipsilateral lung, double lungs, contralateral breast, heart and spinal cord than IMRT (P<0.05). A lower MU per 2.0-Gy fraction was required for 1ARC (539 MU) and 2ARC (608 MU) than for IMRT (1,051 MU). Thus, TTT was correspondingly reduced in 1ARC and 2ARC compared to IMRT (P<0.05). There was no significant dose-volume difference in all the organs at risk (OARs) between the 1ARC and 2ARC plans (P>0.05), and 2ARC VMAT displayed a better HI and CI than 1ARC VMAT (P<0.05). By contrast, 1ARC VMAT was superior to 2ARC VAMT with regard to MU and TTT (P<0.05). The 1ARC and 2ARC VMAT plans demonstrated significantly better dose distribution in a shorter treatment time than IMRT for post-mastectomy regional irradiation, and spared the majority of OARs without compromising target coverage. The results of the present study suggest that 2ARC VMAT may be an alternative to 1ARC in order to obtain a more optimal HI and CI.
Collapse
Affiliation(s)
- Li-Rong Zhao
- Cancer Institute of the People's Liberation Army, Xinqiao Hospital, Third Military Medical University, Chongqing 400037, P.R. China
| | - Yi-Bing Zhou
- Cancer Institute of the People's Liberation Army, Xinqiao Hospital, Third Military Medical University, Chongqing 400037, P.R. China
| | - Jian-Guo Sun
- Cancer Institute of the People's Liberation Army, Xinqiao Hospital, Third Military Medical University, Chongqing 400037, P.R. China
| |
Collapse
|
49
|
Thomson DJ, Beasley WJ, Garcez K, Lee LW, Sykes AJ, Rowbottom CG, Slevin NJ. Relative plan robustness of step-and-shoot vs rotational intensity–modulated radiotherapy on repeat computed tomographic simulation for weight loss in head and neck cancer. Med Dosim 2016; 41:154-8. [DOI: 10.1016/j.meddos.2016.01.001] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2014] [Revised: 10/12/2015] [Accepted: 01/13/2016] [Indexed: 10/22/2022]
|
50
|
Pokhrel D, Sood S, McClinton C, Shen X, Lominska C, Saleh H, Badkul R, Jiang H, Mitchell M, Wang F. Treatment planning strategy for whole-brain radiotherapy with hippocampal sparing and simultaneous integrated boost for multiple brain metastases using intensity-modulated arc therapy. Med Dosim 2016; 41:315-322. [DOI: 10.1016/j.meddos.2016.08.001] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2016] [Revised: 06/23/2016] [Accepted: 08/19/2016] [Indexed: 12/25/2022]
|