1
|
Demir N, Genc O, Akkese IB, Malkoc MA, Ozcan M. Bonding Effectiveness of Saliva-Contaminated Monolithic Zirconia Ceramics Using Different Decontamination Protocols. BIOMED RESEARCH INTERNATIONAL 2024; 2024:6670159. [PMID: 38606199 PMCID: PMC11008971 DOI: 10.1155/2024/6670159] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Revised: 03/07/2024] [Accepted: 03/16/2024] [Indexed: 04/13/2024]
Abstract
Objective This research study investigated the effect of new decontamination protocols on the bonding capacity of saliva-contaminated monolithic zirconia (MZ) ceramics cemented with two different monomer-containing self-adhesive resin cements. Materials and Methods Standardized tooth preparations (4 mm. axial height) were performed for eighty human maxillary premolars under constant water cooling system. Eighty monolithic zirconia crowns (Whitepeaks Supreme Monolith) (n = 8/10 groups) were manufactured by CAD-CAM. Specimens were kept in the artificial saliva at pH = 7.3 for 1 minute at 37°C except control groups. The specimens have not been prealumina blasted and grouped according to cleaning methods and resin cements: control groups (C) (no saliva contamination + GPDM + 4-META (N) (CN) and 10-MDP (M) containing resin cement (CM), alumina blasted (AL) + GPDM + 4-META (ALN) and 10-MDP containing resin cement (ALM), zirconium oxide containing universal cleaning agent (IC) applied + GPDM + 4-META (N) (ICN) and 10-MDP containing resin cement (ICM), pumice (P) applied + GPDM + 4-META (PN) and 10-MDP containing resin cement (PM), and air-water spray (AW) applied + GPDM + 4-META (AWN) and 10-MDP containing resin cement (AWM)). Monobond Plus was applied to all surfaces for 40 seconds before cementation. The thermal cycle was applied at 5,000 cycles after cementation. The crowns were tested in tensile mode at a speed of 1 mm/min. The mode of failure was recorded. SEM examinations were carried out at different magnifications. Data were analyzed using rank-based Kruskal-Wallis and Mann-Whitney tests. Results No significant differences were found between the surface treatments and between the two types of resin cements. Interaction effects between surface treatments and resin cements were found to be significant by two-way ANOVA analysis. ICM group resulted in significantly better bond strength results compared with CN. ICM was found to result in better bond strength results compared with PM. The combination of universal cleaning agent and 10-MDP containing resin cement had significantly the highest cementation bond strength values. The increasing order of mean tensile bond strength values of decontamination protocols was C < AW < P < AL < IC. The mean tensile bond strength of 10-MDP containing resin cement was slightly higher than GPDM + 4-META containing resin cement. Conclusions Universal cleaning agents can be preferred as an efficient cleaning method with 10-MDP-containing cement after saliva contamination for better adhesive bond strength of 4 mm crown preparation height of monolithic zirconia ceramics.
Collapse
Affiliation(s)
- Necla Demir
- Selcuk University, Faculty of Dentistry, Department of Prosthodontics, Konya, Türkiye
| | - Ozge Genc
- Selcuk University, Faculty of Dentistry, Department of Prosthodontics, Konya, Türkiye
| | - Ipek Balevi Akkese
- Selcuk University, Faculty of Dentistry, Department of Prosthodontics, Konya, Türkiye
| | - Meral Arslan Malkoc
- Akdeniz University, Faculty of Dentistry, Department of Prosthodontics, Antalya, Türkiye
| | - Mutlu Ozcan
- Clinic for Fixed and Removable Prosthodontics and Dental Materials Science, Center for Dental and Oral Medicine, University of Zurich, Zurich, Switzerland
| |
Collapse
|
2
|
Delikan E, Çaliskan S, Çalışkan A, Özdemir C. Does repeated autoclave sterilization cause changes in the color and fragility of fiberglass reinforced resin crowns? BMC Oral Health 2023; 23:533. [PMID: 37528379 PMCID: PMC10394804 DOI: 10.1186/s12903-023-03254-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Accepted: 06/22/2023] [Indexed: 08/03/2023] Open
Abstract
BACKGROUND Since the effects of sterilization on the Fiberglass Reinforced Resin Crowns (FRRCs) is not well-known the aim of current study was to evaluate the effects of autoclave sterilization on the fracture resistance, color stability, and surface composition of FRRCs. METHODS A total of 48 crowns were used. The crowns were divided into three groups according to the sterilization number: no sterilization (Control Group), one sterilization (Group 1), and four sterilizations (Group 2). The microstructure of the three crowns from each group was evaluated using scanning electron microscopy (SEM) and energy-dispersive X-ray (EDX) spectroscopy. Thirteen FRRCs from each group were first used for color stability testing and then for the fracture resistance analysis. One-way analysis of variance (ANOVA), one-way repeated measures ANOVA, and paired t-tests were used in the statistical analysis. RESULTS EDX results revealed that the weight% of surface silicon atoms in group 2 was significantly higher. Some crack lines could be observed on the SEM images. Statistically significant differences were found in color stability following the first and fourth sterilization cycles (p < .01). The increase in the sterilization cycle did not statistically decrease the fracture resistance of the FRRCs (p = .055); however, overall, a decreasing trend was observed in fracture resistance as the sterilization cycle increased. CONCLUSIONS Autoclave sterilization caused some changes in the surface elemental composition and surface morphology of FRRCs. Avoiding unnecessary FRRC trials is important to reduce the number of sterilizations.
Collapse
Affiliation(s)
- Ebru Delikan
- Department of Pediatric Dentistry, Faculty of Dentistry, Nuh Naci Yazgan University, Kayseri, Turkey
| | - Seçil Çaliskan
- Department of Pediatric Dentistry, Faculty of Dentistry, Eskişehir Osmangazi University, Eskişehir, Turkey.
| | - Ahmet Çalışkan
- Special Uzman Diş Grup Oral and Dental Health Polyclinic, İzmit, Turkey
| | | |
Collapse
|
3
|
Yazigi C, Kern M, Chaar MS. Comparison of bond strength to three restorative materials after contamination and the use of two cleaning agents. J Prosthet Dent 2023:S0022-3913(23)00401-8. [PMID: 37438166 DOI: 10.1016/j.prosdent.2023.06.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Revised: 06/05/2023] [Accepted: 06/07/2023] [Indexed: 07/14/2023]
Abstract
STATEMENT OF PROBLEM Scientific data on the decontamination effectiveness of a newly introduced cleaning agent are lacking. PURPOSE The purpose of this in vitro study was to evaluate and compare the tensile bond strength (TBS) of 3 different restorative bonding surfaces after contamination with saliva following different cleaning protocols. MATERIAL AND METHODS A total of 192 disk specimens were made out of 3 materials (n=64); Katana Avencia (A), Katana Zirconia (Z), and e.max CAD (L). The bonding surfaces of all disks were polished, steam cleaned, and then pretreated by following the recommended protocol for each material. The specimens of each group were divided into 4 subgroups (n=16). The first subgroup served as the reference (R), where no contamination was applied. The 3 other subgroups were contaminated with saliva and subsequently rinsed with water for 20 seconds and dried with oil- and water-free air spray. They were then either not treated with any cleaning method (0), cleaned with Katana Cleaner (K), or cleaned with Ivoclean (I). The bonding surfaces of the specimens were perpendicularly luted to plexiglass tubes filled with dual-polymerizing composite resin (Clearfil DC Core) with resin cement (Panavia V5) after the recommended surface conditioning. Each subgroup was further subdivided into 2 groups: stored in 37 °C water for 3 days or subjected to thermal-cyclic loading for 150 days with 37 500 thermal cycles (7500 per month), temperature 5 to 55 °C, and dwell time of 30 seconds. All specimens were subjected to TBS testing in a universal testing machine. Three-way ANOVA was applied. A significant interaction (P<.01) was detected between the 3 different variables (material, treatment, aging). After significant interactions had been revealed by 3-way ANOVA, additional statistical analysis was performed by using separate 2-way ANOVAs, then separate 1-way ANOVAs followed by the Tukey-HSD test for post hoc pairwise comparisons among groups (α=.05 for all tests). All specimens underwent failure mode analysis after TBS testing RESULTS: All specimens survived the storage with thermocycling except for group Z-0, where all specimens debonded during thermocycling. The mean ±standard deviation TBS values ranged from 18.3 ±5.3 MPa to 34.0 ±5.4 MPa after 3 days and from 6.7 ±5.5 MPa to 26.9 ±5.4 MPa after 150 days. CONCLUSIONS Contaminated groups that did not receive any cleaning had significantly lower TBS. Thermocycling had a negative effect on the TBS but was not statistically significant for all groups. Using the same cleaning method, the restorative material did had a significant effect on the TBS after 150 days.
Collapse
Affiliation(s)
- Christine Yazigi
- Assistant Professor, Department of Prosthodontics, Propaedeutics, and Dental Materials, School of Dentistry, Christian-Albrechts University at Kiel, Kiel, Schleswig-Holstein, Germany.
| | - Matthias Kern
- Professor and Chairman, Department of Prosthodontics, Propaedeutics, and Dental Materials, School of Dentistry, Christian-Albrechts University at Kiel, Kiel, Schleswig-Holstein, Germany
| | - M Sad Chaar
- Senior Lecturer, Department of Prosthodontics, Propaedeutics, and Dental Materials, School of Dentistry, Christian-Albrechts University at Kiel, Kiel, Schleswig-Holstein, Germany
| |
Collapse
|
4
|
Darwich RA, Awad M, Abou Neel EA. Effect of Different Decontamination Methods on Fracture Resistance, Microstructure, and Surface Roughness of Zirconia Restorations-In Vitro Study. MATERIALS (BASEL, SWITZERLAND) 2023; 16:2356. [PMID: 36984236 PMCID: PMC10056380 DOI: 10.3390/ma16062356] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/25/2023] [Revised: 02/25/2023] [Accepted: 03/10/2023] [Indexed: 06/18/2023]
Abstract
This study aimed to evaluate the effect of seven different decontamination methods (water, ZirCleanTM, 37% phosphoric acid, 9.5% hydrofluoric acid, Al2O3 sandblasting, low-speed dental stone, and high-speed dental stone) on the fracture resistance, microstructure, and surface roughness of monolithic and multilayered zirconia. The as-received and sandblasted zirconia was used as a control. One-way ANOVA and t-test were performed. As-received monolithic zirconia was stronger (856 ± 94 MPa) than multilayered zirconia (348.4 ± 63 MPa). Only phosphoric acid (865 ± 141 MPa) and low-speed dental stone (959 ± 116 MPa) significantly increased the flexural strength of sandblasted monolithic zirconia (854 ± 99 MPa), but all tested decontamination methods except phosphoric acid (307 ± 57 MPa) and Al2O3 (322 ± 69 MPa) significantly increased the flexural strength of sandblasted multilayered zirconia (325 ± 74 MPa). Different decontamination methods did not significantly affect the flexural modulus, but introduced irregularities in the crystal as well as deep surface flaws in both types of zirconia. The surface of sandblasted monolithic zirconia is more resistant to change than multilayered zirconia. Among different decontamination methods, a low-speed dental stone could be beneficial as it significantly increased the surface roughness and fracture resistance of both types of zirconia.
Collapse
Affiliation(s)
- Rama A. Darwich
- Preventive and Restorative Dentistry Department, College of Dental Medicine, University of Sharjah, Sharjah P.O. Box 27272, United Arab Emirates
| | - Manal Awad
- Preventive and Restorative Dentistry Department, College of Dental Medicine, University of Sharjah, Sharjah P.O. Box 27272, United Arab Emirates
| | - Ensanya A. Abou Neel
- Preventive and Restorative Dentistry Department, College of Dental Medicine, University of Sharjah, Sharjah P.O. Box 27272, United Arab Emirates
- UCL Eastman Dental Institute, Biomaterials & Tissue Engineering, Royal Free Hospital, Rowland and Hill Street, London NW3 2QG, UK
| |
Collapse
|
5
|
Thammajaruk P, Guazzato M, Naorungroj S. Cleaning methods of contaminated zirconia: A systematic review and meta-analysis. Dent Mater 2023; 39:235-245. [PMID: 36754733 DOI: 10.1016/j.dental.2023.01.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Revised: 01/31/2023] [Accepted: 01/31/2023] [Indexed: 02/08/2023]
Abstract
OBJECTIVES The aims of this study were to systematically review the literature and statistically analyze the effectiveness of different cleaning methods on the bond strength of resin cement to zirconia in short- and long-term aging conditions. DATA/SOURCES The literature was electronically searched in PubMed (MEDLINE), EMBASE, Wiley, Scopus, and Open Access Theses and Dissertations databases to select relevant articles that evaluated the bond strength between contaminated zirconia and resin cements. A manual search was performed by scanning the reference lists of included studies. STUDY SELECTION All articles were published online before April 2022 and in English. Meta-analyses were conducted using random effects models to calculate standardized mean differences (SMD) between uncontaminated zirconia and various cleaning methods in two aging conditions (short- and long-term). Statistical heterogeneity was assessed using I-square statistics. The risk of bias of all included studies was assessed. All statistical analyses were conducted using STATA (StataCorp, College Station, Texas). RESULTS Of the 1181 studies, 25 studies met the inclusion criteria for qualitative analyses. In short-term aging condition, cleaning contaminated zirconia with water, alcohol, or acid etching reported significantly lower bond strength than uncontaminated zirconia. For long-term aging condition, cleaning contaminated zirconia with water, cleaning agents, alcohol, or acid etching reported significantly lower bond strength than uncontaminated zirconia. Alumina air-abrasion or cleaning with sodium hypochlorite were comparable to uncontaminated zirconia for both short- and long-term aging conditions. CONCLUSIONS This meta-analysis appeared to indicate that the cleaning methods of contaminated zirconia restoration have an effect on zirconia bonding.
Collapse
Affiliation(s)
- Putsadeeporn Thammajaruk
- Department of Prosthetic Dentistry, Faculty of Dentistry, Prince of Songkla University, Songkhla 90110, Thailand.
| | - Massimiliano Guazzato
- Discipline of Prosthodontics, School of Dentistry, Faculty of Medicine and Health, The University of Sydney, NSW 2145, Australia
| | - Supawadee Naorungroj
- Department of Conservative Dentistry, Faculty of Dentistry, Prince of Songkla University, Songkhla 90110, Thailand
| |
Collapse
|
6
|
Recen D, Yildirim B, Çeliksöz Ö. The effects of applying a novel cleaner on the bonding strength of zirconia surfaces. Proc Inst Mech Eng H 2023; 237:385-394. [PMID: 36727619 DOI: 10.1177/09544119231151268] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
This study evaluates how pre-treatment with an MDP-containing cleaning agent (Katana Cleaner, Kuraray) influences the micro-shear bond strength (µSBS) of saliva-contaminated zirconia when used with universal adhesive (UA) systems. Rectangular specimens (2 mm × 12 mm × 15 mm) were obtained (IPS, e.max ZirCAD, MO, B65L17, Ivoclar Vivadent) and divided into three groups; a non-contaminated group (control group)(CON), a contaminated and cleaned with isopropyl alcohol group(ISP), and lastly, a group contaminated and cleaned with an MDP-containing cleaning agent(KAC). Each group was then subdivided into three subgroups according to the UAs used (n = 12). Composite cylinders were prepared and bonded to each surface with Panavia V5 (Kuraray, Noritake Dental). A µSBS test was performed and the data were evaluated with the two-way analysis of variance (two-way ANOVA) and multiple comparisons test (α = 0.05). The highest µSBS values were obtained in the non-contaminated group (p < 0.001), regardless of UAs. All subgroups showed lower µSBS values after saliva contamination, but KAC resulted in significantly higher µSBS values than 99% isopropanol (p < 0.001). Overall, the lowest µSBS value was obtained with 99% isopropanol. The KAC-Clearfil UA subgroup resulted in statistically significantly higher µSBS values than the other UAs (p = 0.035 and 0.007), although all three UAs resulted in sufficient µSBS values. This study revealed that applying KAC followed by a UA containing phosphate monomers produces promising results for improving µSBS values of zirconia, greater than results using 99% isopropanol.Clinical relevance: An MDP-containing cleaning agent followed by a phosphate monomer containing a universal adhesive is a promising method to obtain acceptable bonds with saliva-contaminated zirconia ceramics.
Collapse
Affiliation(s)
- Duygu Recen
- Faculty of Dentistry, Department of Restorative Dentistry, İzmir Democracy University, İzmir, Turkey
| | - Bengisu Yildirim
- Faculty of Dentistry, Department of Prosthodontics, Usak University, Uşak, Turkey
| | - Özge Çeliksöz
- Faculty of Dentistry, Department of Restorative Dentistry, Eskişehir Osmangazi University, Eskişehir, Turkey
| |
Collapse
|
7
|
Komagata Y, Ikeda H, Yano HT, Nagamatsu Y, Masaki C, Hosokawa R, Shimizu H. Influence of the thickening agent contained in a phosphoric acid etchant on bonding between feldspar porcelain and resin cement with a silane coupling agent. Dent Mater J 2023. [PMID: 36709988 DOI: 10.4012/dmj.2022-176] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Phosphoric acid (PA) etchants are widely used for the bonding pretreatment of teeth; however, their influences on the bonding between glass-ceramics and resin cement have not been clarified yet. This study investigated the effect of a thickening agent on the bonding strength between feldspar porcelain treated with a PA etchant and resin cement with a silane coupling agent. The experiments were performed using two PA etchants: commercial one and prepared one consisting a PA aqueous solution and poly(ethylene glycol) thickening agent. The samples were evaluated by shear bond strength testing, scanning electron microscopy, and Fourier-transform infrared spectroscopy. The obtained results revealed that the thickening agent adhered to the porcelain surface and inhibited cement bonding. Meanwhile, PA remained on the surface due to the presence of the thickening agent and activated the silane coupling agent. Overall, the PA etchant did not improve the bond durability.
Collapse
Affiliation(s)
- Yuya Komagata
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University
| | - Hiroshi Ikeda
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University
| | - Haruka Takasue Yano
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University.,Division of Oral Reconstruction and Rehabilitation, Department of Oral Functions, Kyushu Dental University
| | - Yuki Nagamatsu
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University
| | - Chihiro Masaki
- Division of Oral Reconstruction and Rehabilitation, Department of Oral Functions, Kyushu Dental University
| | - Ryuji Hosokawa
- Division of Oral Reconstruction and Rehabilitation, Department of Oral Functions, Kyushu Dental University
| | - Hiroshi Shimizu
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University.,Fukuoka Dental College
| |
Collapse
|
8
|
Komagata Y, Ikeda H, Fujio Y, Nagamatsu Y, Shimizu H. Effect of phosphoric acid and sodium hydroxide on cleaning and bonding of saliva-contaminated feldspar porcelain. J Prosthodont Res 2023; 67:132-137. [PMID: 35431286 DOI: 10.2186/jpr.jpr_d_21_00326] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
Purpose Hydrofluoric acid has been used to remove salivary contamination in dental glass-ceramics before bonding treatment. However, alternative methods are required because hydrofluoric acid is harmful. This study examined the cleaning effects of phosphoric acid and sodium hydroxide on glass-ceramics for bonding pre-treatment.Methods Feldspar porcelain was divided into four groups: (C) cleaned porcelain without any contamination, (S) porcelain contaminated with saliva, (SPA) porcelain cleaned with 37% phosphoric acid after saliva contamination, and (SSH) porcelain cleaned with 10% sodium hydroxide after saliva contamination. Each sample was bonded to the resin cement using a silane-containing primer. They were then subjected to a shear bond strength (SBS) test. Each surface was analyzed by scanning electron microscopy (SEM), contact angle measurements, and Fourier transform infrared spectroscopy (FT-IR).Results The SBS of group SSH was comparable to that of group C but significantly higher than that of groups S and SPA. SEM observations showed that saliva-like structures remained on the samples of groups S and SPA, but not on the SSH group. The contact angles of groups C and SSH were comparable and significantly smaller than those of groups S and SPA, respectively. FT-IR analysis also revealed saliva in groups S and SPA, which was absent in the SSH group.Conclusions The saliva remained on the porcelain even after cleaning with phosphoric acid, and SBS was not restored to the same level as before the contamination. In contrast, sodium hydroxide eliminated saliva and restored SBS to the same level as before contamination.
Collapse
Affiliation(s)
- Yuya Komagata
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Fukuoka, Japan
| | - Hiroshi Ikeda
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Fukuoka, Japan
| | - Yuki Fujio
- Sensing System Research Center, National Institute of Advanced Industrial Science and Technology (AIST), Saga, Japan
| | - Yuki Nagamatsu
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Fukuoka, Japan
| | - Hiroshi Shimizu
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Fukuoka, Japan
| |
Collapse
|
9
|
Feiz A, Rastghalam N, Swift EJ. Effect of different cleansing methods on the artificially aged bond strength of resin to contaminated zirconia: A systematic review. J Prosthodont 2022; 31:e125-e137. [PMID: 35912851 DOI: 10.1111/jopr.13580] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2022] [Accepted: 07/25/2022] [Indexed: 01/04/2023] Open
Abstract
PURPOSE The aim of this review was to evaluate studies investigating the effect of cleansing methods on the artificially aged bond strength of resin to contaminated zirconia restorations and determine which cleansing method of contaminated zirconia for resin bonding improvement is more efficient. METHODS An electronic search of published studies in English language was carried out until July 2021 on Scopus, Web of Science, and Medline databases. Data from in vitro studies involving the evaluation of the artificially aged bond strength of resin to contaminated zirconia following different cleansing methods were included. In vitro studies in which samples were not subjected to at least 5000 thermocycles, were excluded. RESULTS Of 162 articles retrieved initially, 19 were eligible to be included in the systematic review, of which 5 articles were excluded. Therefore, the final sample was 14 in vitro studies. All of the included studies for air abrasion suggested this method as an effective cleansing method, but 6 of 8 included studies reported cleaning paste (Ivoclean) as an effective cleansing method. All of the included studies for NaOCl and a cleaning gel (AD Gel) reported their efficacy. Finally, the results of included studies showed the ineffectiveness of phosphoric acid, water, isopropanol, enzymatic detergents, hydrogen peroxide, and acetone. CONCLUSIONS Air abrasion has been reported as an effective cleansing method to improve the bond strength of resin to contaminated zirconia. To improve the effectiveness of cleaning paste in resin bonding, another efficient cleansing method should be followed after this method. However, the superior cleaning potential of air abrasion rather than cleaning paste has been reported. Sodium hypochlorite and cleaning gel seem to be as effective as air abrasion, but extensive water-rinsing is necessary after the application of these cleaning agents.
Collapse
Affiliation(s)
- Atiyeh Feiz
- Dental Materials Research Center, Dental Research Institute, Department of Operative Dentistry, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Niki Rastghalam
- School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Edward J Swift
- Department of Operative Dentistry, University of North Carolina, School of Dentistry, Chapel Hill, North Carolina
| |
Collapse
|
10
|
Abou-Ayash S, Molinero-Mourelle P, Schönenberger A, Belser UC, Brägger U, Flury S. Indirect repair of saliva-contaminated materials using veneering ceramics. J Prosthodont 2022. [PMID: 35942518 DOI: 10.1111/jopr.13579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Accepted: 07/25/2022] [Indexed: 11/29/2022] Open
Abstract
PURPOSE To analyze the in vitro efficacy of a surface conditioning liquid facilitating ceramic repairs of saliva-contaminated metal-ceramic and all-ceramic restorations. MATERIALS AND METHODS Specimens constructed from non-precious alloy (NPA), precious alloy (PA), lithium-disilicate (LD), zirconia (ZI), veneering ceramics for zirconia (VZI), veneering ceramics for lithium-disilicate (VLD), and veneering ceramics for metal alloys (VM) were manufactured (total: n = 168; each material n = 24). Veneering ceramic cylinders (thickness: 2mm) were hand-layered on top of the specimens. Shear bond strength (SBS) tests were performed, measuring the maximum bond strength (MBS) of the cylinders on the specimens. Following this, the specimens were artificially aged and stored in artificial saliva for 30 days at 37°C. After physical cleaning using aluminum oxide air abrasion, a new surface conditioning liquid was applied (test, n = 84) or not (control, n = 84). New ceramic cylinders were hand-layered followed by a second SBS test. Descriptive statistics, linear regression analyses, and a one-sample t-test (α = 0.05) were used to ascertain the differences within (pre- vs. post-repair) and between the groups. RESULTS All specimens in the test group could be repaired, whereas 18 repairs in the control group failed. After the repairs, an MBS decrease was observed for the NPA specimens of the control group (-15.5MPa, p = 0.004) but not among any of the test groups. Comparing the change in MBS between the test and control groups, the reduction was significantly higher in the repaired NPA specimens of the control group (mean difference 11.8 MPa, p = 0.017). CONCLUSIONS Using the analyzed surface conditioning liquid, metal-ceramic and all-ceramic materials can be repaired, while some repairs failed without the liquid. The initial bond strengths between core and veneering materials could be restored in all specimens when the new surface conditioning liquid was applied. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Samir Abou-Ayash
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Pedro Molinero-Mourelle
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | | | - Urs Christophe Belser
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Urs Brägger
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Simon Flury
- Department of Preventive, Restorative, and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland
| |
Collapse
|
11
|
Hajjaj MS, Alzahrani SJ. Effect of Different Cleaning Methods on Shear Bond Strength of Resin Cement to Contaminated Zirconia. MATERIALS 2022; 15:ma15145068. [PMID: 35888534 PMCID: PMC9324905 DOI: 10.3390/ma15145068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/04/2022] [Revised: 07/08/2022] [Accepted: 07/12/2022] [Indexed: 11/14/2022]
Abstract
The aim of this study was to evaluate the effect of different cleaning methods on the shear bond strength (SBS) of resin cement to contaminated zirconia specimens. Eighty rectangular-shaped specimens (2 × 5 × 10 mm) were fabricated from Zirconia blocks (IPS e.max ZirCAD) and randomly divided into 8 groups (n = 10). Group A (control) was not exposed to contaminants. The following tests specimens were contaminated with saliva and silicone indicating paste. Group B was coated with ceramic primer, then subjected to contamination. Groups C, D, E, F, G, and H were contaminated; cleaned with water rinse, Ivoclean, air particle abrasion, hydrofluoric acid, KATANATM Cleaner and ZirCleanTM, respectively, and then coated with ceramic primer and bonded to dual cure resin cement cylinders. All the specimens were subjected to artificial aging and surviving specimens were subjected to the SBS test. For statistical analysis, ANOVA and multiple comparison methods at the 0.05 significance level were used. There was no statistically significant difference among Ivoclean (21.48 ± 2.90 MPa), air particle abrasion (21.92 ± 2.85 MPa), and the control group (24.68 ± 5.46). The application of ceramic primer before contamination did not preserve the SBS of resin cement to zirconia. Cleaning the contaminated zirconia surface with hydrofluoric acid (15.03 ± 3.63) or KATANATM Cleaner (17.27 ± 7.63) did not restore SBS to the uncontaminated state, but it was significantly higher than simply rinsing with water (12.46 ± 5.17) or the use of ZirCleanTM (11.59 ± 5.53). The bond strength of resin cement to zirconia was influenced by cleaning methods.
Collapse
|
12
|
Thalacker C. Dental adhesion with resin composites: a review and clinical tips for best practice. Br Dent J 2022; 232:615-619. [PMID: 35562453 DOI: 10.1038/s41415-022-4144-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Accepted: 02/10/2022] [Indexed: 11/09/2022]
Abstract
Modern restorative dentistry would not be possible without the ability to bond to tooth structure. The development of dental adhesives has a lengthy gestation, from the beginnings around 1950, to the latest generation: modern universal adhesives, which were introduced during the 2010s. The foundation for these developments was a deeper understanding of the mechanisms of adhesion to the tooth structure, and to restoration materials. Typically, the performance of an adhesive does not depend on the use of a single ingredient, but on an overall balanced and optimised formulation that contains various components with different roles, such as functional adhesive monomers.While a wealth of literature exists on adhesives that have a long and successful clinical history ('gold standards'), some universal adhesives have also accumulated a lot of scientific evidence while offering benefits like ease of use, low technique sensitivity and versatility.To achieve reliable results with a modern adhesive, several tips should be kept in mind regardless of the product, which result in a homogeneous adhesive layer, proper cure and ultimately high bond strength. Although high performance is already achieved with the adhesives currently available, this is still an exciting area of ongoing research.
Collapse
Affiliation(s)
- Christoph Thalacker
- Oral Care Solutions Division, 3M Company, ESPE Platz, Seefeld, 82229, Germany.
| |
Collapse
|
13
|
Takahashi K, Yoshiyama T, Yokoyama A, Shimada Y, Yoshiyama M. Effect of decontamination materials on bond strength of saliva-contaminated CAD/CAM resin block and dentin. Dent Mater J 2022; 41:601-607. [PMID: 35418548 DOI: 10.4012/dmj.2021-268] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The aim of this study was to evaluate the effect of decontamination agents against saliva contamination on the bonding of computer-aided design/computer-aided manufacturing (CAD/CAM) resin block. Three commercially available decontamination agents were used in this study. The samples were subjected to microtensile bond strength test. A saliva protein staining test was performed by the pigment binding method to investigate the effect of removing saliva protein. All the decontamination agents could significantly restore the bond strength from the saliva contamination, and KATANA Cleaner showed no significant difference with the control. From the results of the saliva protein staining test, KATANA Cleaner showed higher removal effect of saliva protein for CAD/CAM resin block surface than the other materials due to the surface active effect of MDP salt. It was suggested that cleaners containing MDP salt were more effective in removing artificial saliva contamination than cleaners containing other ingredients for CAD/CAM resin blocks.
Collapse
Affiliation(s)
- Kei Takahashi
- Department of Operative Dentistry, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
| | - Tomohiro Yoshiyama
- Department of Operative Dentistry, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
| | - Akihito Yokoyama
- Department of Operative Dentistry, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
| | - Yasushi Shimada
- Department of Cariology and Operative Dentistry, Graduate school of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Masahiro Yoshiyama
- Department of Operative Dentistry, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
| |
Collapse
|
14
|
Fagan J, Vesselovcz J, Puppin-Rontani J, Correr-Sobrinho L, Freitas KMS, Robertson TC, Pacheco RR, Pini NIP, Sundfeld D. Evaluation of Cleaning Methods on Lithium Disilicate Glass Ceramic Surfaces After Organic Contamination. Oper Dent 2022; 47:E81-E90. [DOI: 10.2341/20-176-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/24/2021] [Indexed: 11/23/2022]
Abstract
SUMMARY
The purposes of this study were to 1) evaluate the effectiveness of different cleaning methods from a previously etched and silanized lithium disilicate glass ceramic (EMX) surface after contact with organic fluids (saliva or human blood) and 2) assess the effect of applying a new silane layer after the cleaning methods on the microshear bond strength (mSBS) of resin cement to EMX. EMX discs were etched with 5% hydrofluoric acid (HF) and properly silanized. Three control groups were created (n=10): control (without contamination), saliva positive, and human blood positive. Later, after new contaminations, the samples were distributed into four groups according to the cleaning method (n=20): air–water spray (AWS), 35% phosphoric acid, 70% alcohol, or Ivoclean cleaning paste. After the cleaning methods, subgroups were submitted to a new silane layer application, or not (n=10). All samples received a thin layer of a bonding agent and, subsequently, three light-cured resin cement cylinders were prepared on each EMX surface for the mSBS test. This test was performed on a universal testing machine at a vertical speed of 1 mm/minute until rupture. Contaminated and cleaned silanized EMX surfaces were assessed by scanning electron microscopy (SEM) (n=1). The noncontaminated control group showed an average mSBS of 18.7 MPa, and the positive saliva and human blood control groups yielded a 34% and 42% reduction in bond strength, respectively, compared to the uncontaminated control (p<0.05). For saliva-contaminated surfaces, all cleaning methods were effective and not different from one another or the control group (p>0.05). However, for human blood contamination, only Ivoclean cleaning paste was effective in restoring μSBS to uncontaminated control group levels (p>0.05). SEM images showed a clean surface (ie, with no contaminant residues) after the cleaning methods, regardless of the organic contaminant type. All the assessed cleaning methods were effective in removing saliva from the silanized EMX surface; however, only Ivoclean was able to restore the adhesion quality when the silanized EMX surface was contaminated with human blood.
Collapse
Affiliation(s)
- J Fagan
- João Fagan Junior, DDS, MSc student, Department of Restorative Dentistry and Prosthodontics, Ingá University Center – UNINGÁ, Maringá, PR, Brazil
| | - J Vesselovcz
- João Vesselovcz Junior, DDS, MSc student, Department of Restorative Dentistry and Prosthodontics, Ingá University Center – UNINGÁ, Maringá, PR, Brazil
| | - J Puppin-Rontani
- Júlia Puppin Rontani, DDS, MSc, PhD, Dental Materials Division, Piracicaba School of Dentistry – UNICAMP, Piracicaba, SP, Brazil
| | - L Correr-Sobrinho
- Lourenço Correr Sobrinho, DDS, MSc, PhD, professor, Dental Materials Division, Piracicaba School of Dentistry – UNICAMP, Piracicaba, SP, Brazil
| | - KMS Freitas
- Karina Maria Salvatore de Freitas, DDS, MSc, PhD, professor, Department of Orthodontics and Pediatric Dentistry, Ingá University Center – UNINGÁ, Maringá, PR, Brazil
| | - TC Robertson
- Taylor Cliffe Robertson, DDS candidate, University of Detroit Mercy, School of Dentistry, Detroit, MI, USA
| | - RR Pacheco
- Rafael Rocha Pacheco, DDS, MSc, PhD, assistant professor, Restorative Dentistry, University of Detroit Mercy, School of Dentistry, Detroit, MI, USA
| | - NIP Pini
- Nubia Inocêncya Pavesi Pini, DDS, MSc, PhD, adjunct professor, Department of Restorative Dentistry and Prosthodontics, Ingá University Center – UNINGÁ, Maringá, PR, Brazil
| | - D Sundfeld
- *Daniel Sundfeld, DDS, MSc, PhD, adjunct professor, Department of Restorative Dentistry and Prosthodontics, Ingá University Center – UNINGÁ, Maringá, PR, Brazil
| |
Collapse
|
15
|
Effect of ethyl cellulose coating as an evaluation agent against contamination on the bond strength of zirconia restorations: An in vitro study. J Prosthet Dent 2022; 127:766.e1-766.e9. [PMID: 35272841 DOI: 10.1016/j.prosdent.2022.01.034] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2021] [Revised: 01/28/2022] [Accepted: 01/28/2022] [Indexed: 11/21/2022]
Abstract
STATEMENT OF PROBLEM During the trial placement of zirconia restorations, contamination of the bonding surface is inevitable. Although cleaning methods for contaminated surfaces have been described, a method of preventing saliva contamination of the bonding surface of zirconia restorations is lacking. PURPOSE The purpose of this in vitro study was to investigate an ethyl cellulose coating as an evaluation agent to mitigate the effects of saliva contamination on the bond strength of zirconia restorations. MATERIAL AND METHODS Experimental groups representing different cleaning methods of tetragonal yttria-stabilized tetragonal zirconia polycrystal (4Y-TZP) surfaces were investigated for shear bond strength with a resin luting agent, and the failure mode was analyzed. The 9.0×7.0×5.0-mm zirconia blocks (n=72) were assigned as follows: Group N: uncontaminated control; Group CU: contaminated with saliva, followed by ultrasonic cleaning with ethanol; Group CI: contaminated with saliva, followed by application of a zirconia cleaner; Group PCW: preapplication of a zirconia primer, contaminated with saliva, followed by cleaning with water spray; Group ECU: precoating with the ethyl cellulose agent, contaminated with saliva, followed by removal of the agent in an ultrasonic bath with ethanol. Each group was divided into 3 subgroups (immediate, short-term aging, and long-term aging), and the shear bond strength was measured (n=24). To analyze the bonding surface characteristics, the contact angle was measured (n=5). The surfaces of the zirconia specimens in each experimental group were evaluated by using a field emission scanning electron microscope (n=5). Time-of-flight secondary ion mass spectroscopy was used for the chemical analysis of the conditioned surfaces (n=3). A 2-way analysis of variance (ANOVA) with main effect model for shear bond strength results and a 1-way ANOVA for contact angle data were performed as statistical analysis, followed by the Bonferroni post hoc test (α=.05). RESULTS The shear bond strength was significantly higher in the ECU group than in the groups with the other cleaning methods (P<.05). After the removal of ethyl cellulose with ethanol, the contact angle and surface topography were found to be similar to those of the control group, and no saliva contaminants were identified in the spectroscopy analysis. CONCLUSIONS Coating with ethyl cellulose may protect the bonding surface of zirconia restorations from salivary contamination better than cleaning a contaminated surface.
Collapse
|
16
|
Alqutaibi AY, Ghulam O, Krsoum M, Binmahmoud S, Taher H, Elmalky W, Zafar MS. Revolution of Current Dental Zirconia: A Comprehensive Review. Molecules 2022; 27:1699. [PMID: 35268800 PMCID: PMC8911694 DOI: 10.3390/molecules27051699] [Citation(s) in RCA: 28] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Revised: 02/16/2022] [Accepted: 03/02/2022] [Indexed: 01/27/2023] Open
Abstract
The aim of this article is to comprehensively review the revolution of dental zirconia (Zir), including its types, properties, applications, and cementation procedures. A comprehensive search of PubMed and Embase was conducted. The search was limited to manuscripts published in English. The final search was conducted in October 2021. Newly developed monolithic Zir ceramics have substantially enhanced esthetics and translucency. However, this material must be further studied in vitro and in vivo to determine its long-term ability to maintain its exceptional properties. According to the literature, monolithic translucent Zir has had promising results and a high survival rate. Thus, the utilization of this material is indicated when strength and esthetics are needed. Both the materials and methods used for cementation of monolithic Zir have significantly improved, encouraging dentists to use this material, especially when a conservative approach is required. Zir restorations showed promising outcomes, particularly for monolithic Zir crowns supported with implant and fixed dental prostheses.
Collapse
Affiliation(s)
- Ahmed Yaseen Alqutaibi
- Department of Prosthodontics, College of Dentistry, Taibah University, Al Madinah 41311, Saudi Arabia;
- Department of Prosthodontics, College of Dentistry, Ibb University, Ibb 70270, Yemen
| | - Omar Ghulam
- Dental Department, Prince Mohammad bin Abdulaziz Hospital (Ministry of National Guard-Health Affairs), Madinah 42324, Saudi Arabia; (O.G.); (M.K.); (H.T.)
| | - Majid Krsoum
- Dental Department, Prince Mohammad bin Abdulaziz Hospital (Ministry of National Guard-Health Affairs), Madinah 42324, Saudi Arabia; (O.G.); (M.K.); (H.T.)
| | - Suhail Binmahmoud
- Dental Department, Prince Sultan Armed Forces Hospital, Madinah 42375, Saudi Arabia;
| | - Hasan Taher
- Dental Department, Prince Mohammad bin Abdulaziz Hospital (Ministry of National Guard-Health Affairs), Madinah 42324, Saudi Arabia; (O.G.); (M.K.); (H.T.)
| | - Wael Elmalky
- Department of Restorative Dentistry, College of Dentistry, Taibah University, Al Madinah 41311, Saudi Arabia;
| | - Muhammad Sohail Zafar
- Department of Restorative Dentistry, College of Dentistry, Taibah University, Al Madinah 41311, Saudi Arabia;
- Department of Dental Materials, Islamic International Dental College, Riphah International University, Islamabad 44000, Pakistan
| |
Collapse
|
17
|
Effectiveness of different cleaning measures on the bonding of resin cement to saliva-contaminated or blood-contaminated zirconia. J Dent 2022; 120:104084. [DOI: 10.1016/j.jdent.2022.104084] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2022] [Revised: 02/27/2022] [Accepted: 03/02/2022] [Indexed: 11/19/2022] Open
|
18
|
Komar D, Bago I, Negovetić Vranić D, Kranjčić J, Brkić B, Carek A. Influence of Different Surface Pretreatments of Zirconium Dioxide Reinforced Lithium Disilicate Ceramics on the Shear Bond Strength of Self-Adhesive Resin Cement. Acta Stomatol Croat 2021; 55:264-279. [PMID: 34658373 PMCID: PMC8514231 DOI: 10.15644/asc55/3/4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2021] [Accepted: 08/22/2021] [Indexed: 11/16/2022] Open
Abstract
Aim To analyze the influence of different surface pretreatments of zirconium dioxide reinforced lithium disilicate ceramics on the shear bond strength of self-adhesive resin cement. Materials and methods Eighty-four zirconium reinforced lithium disilicate disc Vita suprinity (Vita Zahnfabrick, Bad Säckingen, Germany) 14x12x2 mm specimens were fabricated according to the manufacturer's recommendations. The specimens were embedded in acrylic resin blocks and randomly divided in seven groups (n=12/each) accorrding to the treatment: Group 1- 10% hydrofluoric acid; Group 2- silane; Group 3- hydrofluoric and silane; Group 4- sandblasting with silane; Group 5- Er: YAG laser+ silane; Group 6- Nd: YAG laser + silane; and the control group, in which the specimens were not treated. Round shape composite discs (Filtek Bulk fill, 3M ESPE, St.Paul, Minnesota, USA) with 3.5 mm diameter, were made for shear bond strength testing, and then cemented to the ceramic sample surface using composite cement (RelyX U200 Automix, 3M ESPE, Neuss, Germany). After cementing the composite disc on the sample, the samples were subjected to shear bond strength test of 10 N with a “stress rate” of 1 MPa / s. To determine the nature of the fracture (adhesive, cohesive or adhesive-cohesive), the broken samples were examined under a stereomicroscope. The ANOVA test and the Tukey test were used to compare the values of the bond strength characteristics between different types of materials. All tests were performed with a significance level of α = 0.05. Results There was a significant difference in the shear bond strength of self-adhesive cement to dental lithium-disilicate ceramics reinforced with zirconium dioxide after different preparation protocols (p<0, 05). The treatment of lithium disilicate ceramics reinforced with zirconium dioxide by silanization, sandblasting + silanization, Nd: YAG + silanization resulted in significantly higher bond strength compared to the control group. There was statistically higher bond strength of self-adhesive cement after pretreatment of lithium disilicate ceramics Nd: YAG + silanization compared to Er: YAG + silanization (p <0.05). Adhesive fracture dominated in the control group, sandblasting + silanization group, and in the laser groups, while mixed fracture dominated in other groups. Conclusion Under the limitations of this study, the Nd:YAG irradiation with silanization could be used as pretreatment for providing greater shear bond strength of self-adhesive resin cement to zirconium reinforced lithium disilicate.
Collapse
Affiliation(s)
- Danijel Komar
- - Dental Polyclinic Zagreb, Department of Prosthodontics, Zagreb
| | - Ivona Bago
- - School of Dental Medicine, University of Zagreb, Department of Endodontics and Restorative Dentistry
| | - Dubravka Negovetić Vranić
- - School of Dental Medicine, University of Zagreb, Department of Children's and Preventive Dentistry
| | - Josip Kranjčić
- - School of Dental Medicine, University of Zagreb, Department of Fixed
| | - Bruna Brkić
- - Split-Dalmatia County Health Center, Split, Croatia
| | - Andreja Carek
- - School of Dental Medicine, University of Zagreb, Department of Fixed
| |
Collapse
|
19
|
Predictable bonding of adhesive indirect restorations: factors for success. Br Dent J 2021; 231:287-293. [PMID: 34508198 PMCID: PMC8433051 DOI: 10.1038/s41415-021-3336-x] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Accepted: 01/26/2021] [Indexed: 11/09/2022]
Abstract
Adhesive indirect restorations are a popular restorative treatment option. This article discusses the many factors that contribute to their successful adhesive cementation, including a review of how to surface treat and manage contaminants across the wide range of indirect materials available. Critiques the current various adhesive strategies used by resin cements at the tooth tissue interface. Describes how to prepare the fitting surface of a wide range of restorative materials for adhesive cementation. Discusses how to mitigate against contaminants during the adhesive cementation process.
Collapse
|
20
|
Atoche-Socola KJ, Arriola-Guillén LE, López-Flores AI, Garcia IM, Huertas-Mogollón G, Collares FM, Branco Leitune VC. Microshear bond strength of dual-cure resin cement in zirconia after different cleaning techniques: an in vitro study. J Adv Prosthodont 2021; 13:237-245. [PMID: 34504675 PMCID: PMC8410303 DOI: 10.4047/jap.2021.13.4.237] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2021] [Revised: 08/11/2021] [Accepted: 08/20/2021] [Indexed: 11/30/2022] Open
Abstract
PURPOSE This study aimed to compare the microshear bond strength (µSBS) of dual-cure resin cement in CAD-CAM zirconia after different cleaning techniques. MATERIALS AND METHODS Fifty discs of zirconia-based ceramic from Ivoclar Vivadent were embedded in acrylic resin. The discs were divided into five groups according to the cleaning methods used: Group 1: drying with spraying + sandblasting with Al2O3; Group 2: washed with water and dried with spraying + sandblasting with Al2O3; Group 3: washed with distilled water and dried with spraying + sandblasting with Al2O3 + zirconium oxide (Ivoclean); Group 4: washed with distilled water and dried with spraying + sandblasting with Al2O3 + potassium hydroxide (Zirclean); and Group 5: washed with distilled water and dried with spraying + sandblasting with Al2O3 + 1% NaClO. All of the groups were contaminated with artificial saliva for 1 minute and then cleaned. Statistical analyses were performed using ANOVA and Tukey's tests. RESULTS There were statistically significant differences among all groups for µSBS (P < .05). The group treated with zirconium oxide (Group 3) showed the highest µSBS (18.75 ± 0.23 MPa). CONCLUSION When applied to zirconia, the cleaning methods affected the bonding with resin cement differently.
Collapse
Affiliation(s)
| | | | - Ana Isabel López-Flores
- Division of Oral Rehabilitation, School of Dentistry, Universidad Científica Del Sur, Lima, Perú
| | - Isadora Martini Garcia
- Dental Materials Laboratory, School of Dentistry, Federal University of Rio Grande do Sul, Ramiro Barcelos, Rio Branco, Porto Alegre, RS, Brazil
| | - Gustavo Huertas-Mogollón
- Division of Oral Rehabilitation, School of Dentistry, Universidad Científica Del Sur, Lima, Perú
| | - Fabrício Mezzomo Collares
- Dental Materials Laboratory, School of Dentistry, Federal University of Rio Grande do Sul, Ramiro Barcelos, Rio Branco, Porto Alegre, RS, Brazil
| | - Vicente Castelo Branco Leitune
- Dental Materials Laboratory, School of Dentistry, Federal University of Rio Grande do Sul, Ramiro Barcelos, Rio Branco, Porto Alegre, RS, Brazil
| |
Collapse
|
21
|
Koko M, Takagaki T, Abdou A, Wada T, Nikaido T, Tagami J. Influence of 10-methacryloyloxydecyl dihydrogen phosphate (MDP) incorporated experimental cleaners on the bonding performance of saliva-contaminated zirconia ceramic. Clin Oral Investig 2021; 26:1785-1795. [PMID: 34417668 DOI: 10.1007/s00784-021-04153-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2021] [Accepted: 08/14/2021] [Indexed: 11/28/2022]
Abstract
OBJECTIVES To assess the efficacy of experimental cleaners containing 10-methacryloyloxydecyl dihydrogen phosphate (MDP) on the saliva decontamination of ceramic and their influence in restoring zirconia's adherence to resin cement. MATERIALS AND METHODS Four hundred sixty alumina-blasted zirconia specimens were categorized into saliva-contaminated and uncontaminated groups which were treated with ceramic primer (P), experimental cleaner 1 (C1), C1 followed by P (C1P), experimental cleaner 2 (C2), and C2 followed by P (C2P). Stainless-steel rods were then attached to the specimens using PanaviaV5 cement (Kuraray Noritake Dental; Tokyo, Japan). Tensile bond strength (TBS) test was performed after 24 h and 5000 thermocycling processes. X-ray photoelectron spectroscopy (XPS) analysis and contact angle measurement of the specimen were performed. The TBS data were analyzed by Weibull analysis and three-way ANOVA. Contact angle data were analyzed by two-way ANOVA (α = 0.05). RESULTS C2P groups showed the highest TBS in all conditions among tested groups. Saliva contamination led to a significant reduction of TBS in primer- and cleaner-treated groups, with no significant impact on C2P. Adhesive failure was predominant in contaminated groups except with the C1P and C2P groups. XPS revealed that a nitrogen peak was observed on contaminated groups but not in primed groups. The contact angle was significantly affected by saliva contamination, the cleaners, and/or ceramic primer usage (p < 0.001). CONCLUSIONS The MDP cleaner followed by the MDP primer protocol may overcome the effect of saliva contamination and improve the resin-ceramic bond strength. CLINICAL RELEVANCE It is recommended to use a combination of MDP-containing cleaner 2 and ceramic primer as a chair-side chemical pretreatment for zirconia substrate with or without saliva contamination.
Collapse
Affiliation(s)
- Minkhant Koko
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan.
- Department of Conservative Dentistry, University of Dental Medicine Mandalay, Chanmyathazi, Mandalay, 05041, Myanmar.
| | - Tomohiro Takagaki
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan
- Department of Operative Dentistry, Division of Oral Functional Science and Rehabilitation, School of Dentistry, Asahi University, 1851 Hozumi, Mizuho, Gifu, 501-0296, Japan
| | - Ahmed Abdou
- Biomaterials Department, Faculty of Dentistry, Modern University for Technology and Information, Mokatam, Cairo, 11571, Egypt.
| | - Takahiro Wada
- Department of Advanced Biomaterials, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan
| | - Toru Nikaido
- Department of Operative Dentistry, Division of Oral Functional Science and Rehabilitation, School of Dentistry, Asahi University, 1851 Hozumi, Mizuho, Gifu, 501-0296, Japan
| | - Junji Tagami
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan
| |
Collapse
|
22
|
Burkhardt F, Pitta J, Fehmer V, Mojon P, Sailer I. Retention Forces of Monolithic CAD/CAM Crowns Adhesively Cemented to Titanium Base Abutments-Effect of Saliva Contamination Followed by Cleaning of the Titanium Bond Surface. MATERIALS (BASEL, SWITZERLAND) 2021; 14:3375. [PMID: 34207110 PMCID: PMC8234922 DOI: 10.3390/ma14123375] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 06/07/2021] [Accepted: 06/14/2021] [Indexed: 11/16/2022]
Abstract
The aim of this study was to investigate the effects of saliva contamination and the cleaning of the bond surface of titanium base (ti-base) abutments on the bonding stability and retention force values. The bond surface of the ti-base abutments was treated with airborne-particle abrasion. After contamination, the ti-base abutments underwent different cleaning protocols: water spray (H2O); alcohol (ALC); suspension of zirconium particles (SZP); reapplied airborne-particle abrasion (APA); and a control condition without contamination and cleaning (CTR). All lithium disilicate crowns were bonded to the ti-base abutments using a primer and a self-curing composite. Bonded specimens underwent thermo-mechanical aging. Bond failure analysis and pull-off testing were performed. Bond failure occurred more frequently in groups H2O, ALC, SZP, and APA (p < 0.05). Significant differences in retention force values were only found between CTR and ALC (p < 0.05). Specimens which did not show bond failure after ageing had higher retention force values than the specimens that showed bond failure (p < 0.05). Saliva contamination with cleaning can degrade the bonding properties to titanium. For the retention force values, only the protocol with alcohol after contamination could not restore the values.
Collapse
Affiliation(s)
- Felix Burkhardt
- Division of Fixed Prosthodontics and Biomaterials, University Clinics of Dental Medicine, University of Geneva, 1211 Geneva, Switzerland; (J.P.); (V.F.); (P.M.); (I.S.)
| | | | | | | | | |
Collapse
|
23
|
UV-Mediated Photofunctionalization of Indirect Restorative Materials Enhances Bonding to a Resin-Based Luting Agent. BIOMED RESEARCH INTERNATIONAL 2021; 2021:9987860. [PMID: 34195290 PMCID: PMC8181058 DOI: 10.1155/2021/9987860] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 04/09/2021] [Accepted: 04/12/2021] [Indexed: 11/18/2022]
Abstract
Purpose The potential of UV-mediated photofunctionalization to enhance the resin-based luting agent bonding performance to aged materials was investigated. Methods Sixty samples of each material were prepared. Yttria-stabilized zirconia (YZr) and Pd-Au alloy (Pd-Au) plates were fabricated and sandblasted. Lithium disilicate glass-ceramic (LDS) was CAD-CAM prepared and ground with #800 SiC paper. Half of the specimens were immersed in machine oil for 24 h to simulate the carbon adsorption. Then, all of the specimens (noncarbon- and carbon-adsorbed) were submitted to UV-mediated photofunctionalization with a 15 W UV-LED (265 nm, 300 mA, 7692 μW/cm2) for 0 (control groups), 5, and 15 min and subjected to contact angle (Ɵ) measurement and bonded using a resin cement (Panavia™ V5, Kuraray Noritake, Japan). The tensile bond strength (TBS) test was performed after 24 h. The Ɵ (°) and TBS (MPa) data were statistically analyzed using two-way ANOVA and Bonferroni correction tests (α = 0.05). Results In the carbon-adsorbed groups, UV-mediated photofunctionalization for 5 min significantly decreased Ɵ of all materials and increased TBS of YZr, and UV for 15 min significantly increased the TBS of LDS and Pd-Au. In noncarbon-adsorbed groups, UV-photofunctionalization did not significantly change the Ɵ or TBS except YZr specimens UV-photofunctionalized for 15 min. Conclusion UV-mediated photofunctionalization might have removed the adsorbed hydrocarbon molecules from the materials' surfaces and enhanced bond strengths of Panavia™ V5 to YZr, LDS, and Pd-Au. Additionally, UV-mediated photofunctionalization improved the overall TBS of YZr. Further investigation on the optimum conditions of UV photofunctionalization on indirect restorative materials should be conducted.
Collapse
|
24
|
Sulaiman TA, Altak A, Abdulmajeed A, Rodgers B, Lawson N. Cleaning Zirconia Surface Prior To Bonding: A Comparative Study of Different Methods and Solutions. J Prosthodont 2021; 31:239-244. [PMID: 33998083 DOI: 10.1111/jopr.13389] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/11/2021] [Indexed: 11/29/2022] Open
Abstract
PURPOSE To evaluate resin cement bond strength after removal of salivary contamination from a zirconia surface using different cleaning solutions and air-borne particle abrasion. MATERIALS AND METHODS One-hundred and twenty zirconia specimens (KATANA STML, Noritake) were prepared and divided into 12 groups (n = 10). Groups were subjected to a notched-edge shear bond strength test (ISO 29022) to analyze the bonding efficiency of a resin cement (Panavia V5, Kuraray Noritake Dental Inc.) before and after contamination with saliva. Group 1 (control) was prepared and cemented without salivary contamination. Group 2 was coated with ceramic primer (Clearfil Ceramic Primer Plus, Kuraray Noritake Dental Inc.) then subjected to salivary contamination then tested. Group 3 was contaminated, cleaned by air-borne particle abrasion, ceramic primer and resin cement applied, and tested. Groups 4 to 12 were contaminated, and then different cleaning solutions (water, 4.5% hydrofluoric acid, 35% phosphoric acid, Ivoclean, KATANA cleaner, Zirclean, sodium hypochlorite 4%, and 7.5%) were used to decontaminate the zirconia surface, followed by ceramic primer, resin cement application, and tested. One-way ANOVA and Tukey post-hoc analysis was used to analyze the data. RESULTS One-way ANOVA showed statistical differences among cleaning procedures (p < 0.001, F = 13.48). Air-borne particle abrasion was the only group which provided a bond strength (21 ± 2.8 MPa) that was not statistically different than the control group in which no contamination occurred (25.3 ± 3.3 MPa) (p = 0.247). The use of hydrofluoric acid and zirconia cleaning solutions resulted in bond strengths values which were not statistically different from each other (17.5-19.1 MPa). CONCLUSION Air-borne particle, zirconia cleaning solutions and hydrofluoric acid are feasible to decontaminate the zirconia surface from saliva prior to bonding the restoration.
Collapse
Affiliation(s)
- Taiseer A Sulaiman
- Division of Comprehensive Oral Health, Adams School of Dentistry, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina
| | - Ali Altak
- Division of Comprehensive Oral Health, Adams School of Dentistry, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina
| | - Awab Abdulmajeed
- Department of General Practice, School of Dentistry, Virginia Commonwealth University, Richmond, Virginia
| | - Brandon Rodgers
- Division of Comprehensive Oral Health, Adams School of Dentistry, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina
| | - Nathaniel Lawson
- Division of Biomaterials, University of Alabama School of Dentistry, Birmingham, Alabama
| |
Collapse
|
25
|
Barto A, Vandewalle KS, Lien W, Whang K. Repair of resin-veneered polyetheretherketone after veneer fracture. J Prosthet Dent 2021; 125:704.e1-704.e8. [PMID: 33546855 DOI: 10.1016/j.prosdent.2020.10.020] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2020] [Revised: 10/30/2020] [Accepted: 10/30/2020] [Indexed: 01/13/2023]
Abstract
STATEMENT OF PROBLEM If a composite resin-veneered polyetheretherketone (PEEK) restoration chips or fractures, a repair may be indicated. However, the most appropriate repair protocol for a composite resin-veneered PEEK restoration is unclear. PURPOSE The purpose of this in vitro study was to determine the efficacy of airborne-particle abrasion and/or a primer in the repair of composite resin-veneered PEEK prostheses. MATERIAL AND METHODS PEEK specimens (N=80) were airborne-particle abraded with alumina before being conditioned with a methyl methacrylate-based primer. A thin layer of opaquer was applied, and a split mold was then filled with a veneering resin. The specimens underwent 5000 thermocycles, and then shear bond strength (SBS) was determined and used as the positive control group. Specimens that failed in either mixed or adhesive modes were contaminated with saliva and then exposed to 4 different repair treatment methods: no airborne-particle abrasion, bonded without a primer (negative control group); airborne-particle abrasion, bonded without a primer; no airborne-particle abrasion, bonded with a primer; and airborne-particle abrasion, bonded with a primer. All specimens had opaquer applied before being veneered. Repaired specimens then underwent thermocycling before SBS testing. Data were analyzed via ANOVA with a Newman-Keuls post hoc test (α=.05). RESULTS The SBS values for the negative control were significantly lower than those of all other repair groups and the control group (P<.018). No significant differences in the SBS values were found among these other repair groups or the positive control group (P>.05). CONCLUSIONS Composite resin-veneered PEEK restorations or prostheses repaired with airborne-particle abrasion and/or primer can provide SBS comparable with that of the initial SBS.
Collapse
Affiliation(s)
- Aaron Barto
- Prosthodontics Resident, Comprehensive Dentistry, University of Texas Health Science Center at San Antonio, San Antonio, Texas; Lieutenant, Dental Corps, United States Navy, Officer Programs- Navy Medicine Training Support Center, JBSA-Fort Sam Houston, San Antonio, Texas
| | - Kraig S Vandewalle
- Consultant in Dental Research, Advanced Education in General Dentistry Residency, US Air Force Postgraduate Dental School, Joint Base San Antonio - Lackland, Texas; Professor, Postgraduate Dental College, Uniformed Services University of the Health Sciences, Bethesda, Md
| | - Wen Lien
- Consultant in Dental Biomaterials, US Air Force Dental Research & Consultation Service, JBSA-Fort Sam Houston, San Antonio, Texas
| | - Kyumin Whang
- Division Head and Director for the Division of Research, Comprehensive Dentistry, University of Texas Health Science Center at San Antonio, San Antonio, Texas.
| |
Collapse
|
26
|
Al-Akhali M, Al-Dobaei E, Wille S, Mourshed B, Kern M. Influence of elapsed time between airborne-particle abrasion and bonding to zirconia bond strength. Dent Mater 2021; 37:516-522. [PMID: 33461761 DOI: 10.1016/j.dental.2020.12.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2020] [Revised: 12/20/2020] [Accepted: 12/30/2020] [Indexed: 10/22/2022]
Abstract
OBJECTIVE The airborne-particle abrasion of zirconia with alumina particle (APA) has been reported to result in the durable bonding of appropriate adhesive luting systems. However, whether a delay between APA and the application of the adhesive luting material might affect the resulting bond strength and its durability is unknown. METHODS A total of 140 disc-shaped zirconia specimens were divided according to the elapsed time between the APA of zirconia and its bonding into 5 test groups (15 min, 1 h, 4 h, 24 h, and 72 h). The specimens were airborne-particle abraded with 50-μm Al2O3, and then stored at room temperature according to the test group (n = 28/group). Surface free energy (SFE) was measured for 12 specimens per group using a goniometer. For each group 16 Plexiglas tubes filled with composite resin were bonded to the zirconia specimens with an adhesive luting resin (Panavia 21). Tensile bond strength (TBS) was tested for subgroups of 8 specimens after water storage for 3 days and for 150 days with 37,500 thermal cycles. RESULTS SFE decreased significantly within 24 h after APA. TBS after 3 days of water storage ranged from 38.3 (1 h) to 28.4 MPa (24 h) and after 150 days with thermocycling from 38.3 (15 min) to 24.8 MPa (24 h). SIGNIFICANCE Based on these results, the time between the APA of zirconia and the application of adhesive materials should be minimized when bonding nonretentive zirconia restorations clinically.
Collapse
Affiliation(s)
- Majed Al-Akhali
- Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian-Albrechts University, Kiel, Germany.
| | - Eglal Al-Dobaei
- Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian-Albrechts University, Kiel, Germany
| | - Sebastian Wille
- Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian-Albrechts University, Kiel, Germany
| | - Bilal Mourshed
- Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian-Albrechts University, Kiel, Germany
| | - Matthias Kern
- Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian-Albrechts University, Kiel, Germany
| |
Collapse
|
27
|
Martínez-Rus F, Rodríguez C, Salido MP, Pradíes G. Influence of different cleaning procedures on the shear bond strength of 10-methacryloyloxydecyl dihydrogen phosphate-containing self-adhesive resin cement to saliva contaminated zirconia. J Prosthodont Res 2021; 65:443-448. [PMID: 33441505 DOI: 10.2186/jpr.jpr_d_20_00157] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE To evaluate the effect of different cleaning methods on the shear bond strength (SBS) of a 10-methacryloyloxydecyl dihydrogen phosphate (MDP)-containing self-adhesive resin cement to zirconia after saliva contamination. METHODS Sixty zirconia specimens were randomly divided into four groups (n=15) according to treatment surface. Except for the control group, all samples were contaminated with saliva and were then rinsed with water-spray and air-dried. Subsequently, the specimens were either treated with a cleaning paste (CP), with argon plasma (AP), or did not undergo an additional cleaning process (WS). An MDP-containing self-adhesive resin cement was applied onto the ceramic surfaces. Specimens were stored in water (24 hours) followed by thermocycling (5°C to 55°C for 10.000 cycles). SBS tests were performed in a universal testing machine, and the results (MPa ± SD) were statistically analyzed using ANOVA and Bonferroni post-hoc test. Fractured surfaces were examined to identify the failure types using a stereomicroscopy and SEM. RESULTS The surface cleaning treatment (p < 0.05) significantly affected the results. The highest SBS values were observed in the control group (12.16 ± 1.22 MPa) and were statistically comparable to values for the CP group (11.38 ± 1.65 MPa). The AP group (9.17 ± 1.06 MPa) showed significantly higher bond strength than the WS group (6.95 ± 1.20 MPa), but it showed significantly lower strength than the control and CP groups. CONCLUSIONS The CP application was the most effective method in removing saliva contamination. The AP treatment could not restore the SBS to the same level as uncontaminated specimens.
Collapse
Affiliation(s)
- Francisco Martínez-Rus
- Department of Conservative and Prosthetic Dentistry, Faculty of Odontology, University Complutense of Madrid, Madrid
| | - Christian Rodríguez
- Department of Conservative and Prosthetic Dentistry, Faculty of Odontology, University Complutense of Madrid, Madrid
| | - María P Salido
- Department of Conservative and Prosthetic Dentistry, Faculty of Odontology, University Complutense of Madrid, Madrid
| | - Guillermo Pradíes
- Department of Conservative and Prosthetic Dentistry, Faculty of Odontology, University Complutense of Madrid, Madrid
| |
Collapse
|
28
|
Li R, Wang C, Ma SQ, Liu ZH, Zang CC, Zhang WY, Sun YC. High bonding strength between zirconia and composite resin based on combined surface treatment for dental restorations. J Appl Biomater Funct Mater 2020; 18:2280800020928655. [PMID: 33147097 DOI: 10.1177/2280800020928655] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Zirconia is the preferred material for dental restorations; however, dental restorations are usually affected by zirconia fractures due to chipping and delamination of the veneer ceramic. One effective solution for repairing chemically inert zirconia frameworks is to strongly chemically bond them with the composite resin via surface modification. Thus, the bonding strength between the zirconia and composite resin determines the performance of dental restoration. Herein, we investigate the shear bond strength between zirconia ceramic and two ceramic repair systems before and after thermal cycling based on different surface pretreatments, including air-abrasion and a novel silane coupling agent. When treated with combined sandblasting, novel silane and 10-methacryloyloxydecyl hydrogen phosphate act as a bonding agent for the zirconia surface, and the maximum shear bond strength achieves 27.5 MPa, as measured by a universal testing machine through the average of 16 separate measurements. The results show that the combined treatment resists the interface damage caused by expansion and contraction during thermal cycling. The long-term bond durability is due to the micro-mechanical bond force formed by resin and ceramic, and the chemical bonds of Zr-O-Si at the interface. Results indicate that selective pretreating the surface results in high bond strength between the zirconia and the composite resin, which is meaningful to optimize dental restoration.
Collapse
Affiliation(s)
- Rui Li
- Department of Prosthodontics, Stomatological Hospital, Tianjin Medical University, Tianjin, China
| | - Chen Wang
- Department of Prosthodontics, Stomatological Hospital, Tianjin Medical University, Tianjin, China
| | - Shi Qing Ma
- Department of Prosthodontics, Stomatological Hospital, Tianjin Medical University, Tianjin, China
| | - Zi Hao Liu
- Department of Prosthodontics, Stomatological Hospital, Tianjin Medical University, Tianjin, China
| | - Cheng Cheng Zang
- Department of Prosthodontics, Stomatological Hospital, Tianjin Medical University, Tianjin, China
| | - Wen Yi Zhang
- Department of Prosthodontics, Stomatological Hospital, Tianjin Medical University, Tianjin, China
| | - Ying Chun Sun
- Department of Prosthodontics, Stomatological Hospital, Tianjin Medical University, Tianjin, China
| |
Collapse
|
29
|
Effect of Cleaning Protocol on Bond Strength between Resin Composite Cement and Three Different CAD/CAM Materials. MATERIALS 2020; 13:ma13184150. [PMID: 32961873 PMCID: PMC7560426 DOI: 10.3390/ma13184150] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/18/2020] [Revised: 09/13/2020] [Accepted: 09/16/2020] [Indexed: 11/16/2022]
Abstract
The present investigation tested the effect of the cleaning method on the tensile bond strength (TBS) between one resin composite cement (RCC) and three different computer aided design/computer aided manufacturing (CAD/CAM) materials, namely zirconia, lithium disilicate ceramic and resin composite. Ninety specimens were prepared from each CAD/CAM material (N = 270). The specimens were pre-treated respectively, divided into five subgroups and subjected to five different cleaning protocols, namely i. 37% phosphoric acid, ii. ethanol, iii. phosphoric acid + ethanol, iv. cleaning paste, v. distilled water. After cleaning, the specimens were either conditioned using a universal primer or a universal adhesive and bonded using a dual-curing RCC. After thermo-cycling (20,000x at 5 °C/55 °C), TBS and fracture patterns were evaluated. The data was analyzed using 1- and 2-way Analysis of Variance (ANOVA) with post-hoc Scheffé and partial eta-squared (ƞP²), Kruskal-Wallis, Mann-Whitney U and Chi2 tests (p < 0.05). The CAD/CAM material showed an impact on the BS while the cleaning protocol did not affect the results. Zirconia obtained the highest BS, followed by lithium-disilicate-ceramic. Resin composite resulted in the overall lowest BS. For most fracture patterns, the cohesive type occurred. All tested cleaning protocols resulted in same BS values within one CAD/CAM material indicating that the impact of the cleaning method for the restorative material seems to play a subordinate role in obtaining durable bond strength to resin composite cement. Further, it indicates that the recommended bonding protocols are well adjusted to the respective materials and might be able to compensate the impact of not accurately performed cleaning protocols.
Collapse
|
30
|
Liu X, Wang H, Yu S, Zhao Q, Shi Z, Cui Z, Zhu S. Construction of a silicate-based epitaxial transition film on a zirconia ceramic surface to improve the bonding quality of zirconia restorations. RSC Adv 2020; 10:32476-32484. [PMID: 35516504 PMCID: PMC9056653 DOI: 10.1039/d0ra04735j] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2020] [Accepted: 08/26/2020] [Indexed: 11/21/2022] Open
Abstract
The effect of a silicate-based epitaxial transition film on zirconia produced by a silicate solution during zirconia-resin bonding was investigated. The airborne-particle abraded zirconia was placed in different concentrations of silicate solutions and heated at 50 °C. The silicate transition film was characterized by scanning electron microscopy (SEM), atomic force microscopy (AFM), energy-dispersive X-ray spectroscopy (EDX), contact angle measurement and profilometry. The silicate-based epitaxial transition film was successfully constructed on the surface of zirconia, and the surface morphology and composition of zirconia changed. After coupling with KH570 hydrolysate, the shear bond strength (SBS) of zirconia-resin after either 24 h water storage or 5000 thermal cycles can be significantly improved by a silicate-based epitaxial transition film on the surface of zirconia, and all the samples had no cytotoxicity. This may provide a new strategy for improving the bonding quality of zirconia restorations.
Collapse
Affiliation(s)
- Xiuju Liu
- Department of Prosthetic Dentistry, School and Hospital of Stomatology, Jilin University Changchun 130021 P. R. China
| | - Han Wang
- Department of Prosthetic Dentistry, School and Hospital of Stomatology, Jilin University Changchun 130021 P. R. China
| | - Shiyang Yu
- Department of Prosthetic Dentistry, School and Hospital of Stomatology, Jilin University Changchun 130021 P. R. China
| | - Qi Zhao
- Department of Prosthetic Dentistry, School and Hospital of Stomatology, Jilin University Changchun 130021 P. R. China
| | - Zuosen Shi
- State Key Lab of Supramolecular Structure and Materials, College of Chemistry, Jilin University Changchun 130021 P. R. China
| | - Zhanchen Cui
- State Key Lab of Supramolecular Structure and Materials, College of Chemistry, Jilin University Changchun 130021 P. R. China
| | - Song Zhu
- Department of Prosthetic Dentistry, School and Hospital of Stomatology, Jilin University Changchun 130021 P. R. China
| |
Collapse
|
31
|
Zhang X, Liang W, Jiang F, Wang Z, Zhao J, Zhou C, Wu J. Effects of air-abrasion pressure on mechanical and bonding properties of translucent zirconia. Clin Oral Investig 2020; 25:1979-1988. [PMID: 32779015 DOI: 10.1007/s00784-020-03506-y] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2020] [Accepted: 08/05/2020] [Indexed: 11/24/2022]
Abstract
OBJECTIVES The purpose of this in vitro study was to investigate the effects of different air-abrasion pressures on flexural strength and shear bond strength of a translucent zirconia. MATERIALS AND METHODS The translucent zirconia surface was treated with 50 μm abrasive alumina particles at different pressure: 0.1 MPa; 0.2 MPa; 0.3 MPa; 0.4 MPa; 0.5 MPa; untreated specimens were used as control group (n = 33). For each group, three-point bending test was used to evaluate the flexural strength, and surface characterizations were analyzed. Following adhesive bonding and water storage for 24 h, specimens were subdivided into groups baseline and aged (5000 thermocycles). Then, shear bond strength was measured and failure mode was recorded. Statistical analysis was performed with one-way ANOVA and Tukey test (α = 0.05). RESULTS Increasing air-abrasion pressure (0.3 MPa, 0.4 MPa, and 0.5 MPa) decreased the flexural strength. Higher air-abrasion pressure resulted in rougher zirconia surfaces and caused more microcracks. The highest shear bond strength was obtained for zirconia surfaces abraded at 0.2 MPa (15.88 ± 2.70 MPa) and 0.3 MPa (14.32 ± 1.12 MPa). Aging did not decrease the strength for all groups except control group (p < 0.001). CONCLUSIONS Air-abrasion with 50 μm abrasive alumina particles at 0.2 MPa could achieve good strength for translucent zirconia ceramics while maintaining adequate and durable bonding with resin cement. CLINICAL RELEVANCE A total of 0.2 MPa is recommended for air-abrasion procedure applied before a dental restoration fabricated with translucent zirconia is bonded to resin cement.
Collapse
Affiliation(s)
- Xinyan Zhang
- Department of Prosthodontics, School and Hospital of Stomatology, Cheeloo College of Medicine, Shandong University & Shandong Key Laboratory of Oral Tissue Regeneration & Shandong Engineering Laboratory for Dental Materials and Oral Tissue Regeneration, Jinan, 250012, China
| | - Wei Liang
- Department of Endodontics, School and Hospital of Stomatology, Cheeloo College of Medicine, Shandong University & Shandong Key Laboratory of Oral Tissue Regeneration & Shandong Engineering Laboratory for Dental Materials and Oral Tissue Regeneration, Jinan, 250012, China
| | - Feng Jiang
- Department of Prosthodontics, School and Hospital of Stomatology, Cheeloo College of Medicine, Shandong University & Shandong Key Laboratory of Oral Tissue Regeneration & Shandong Engineering Laboratory for Dental Materials and Oral Tissue Regeneration, Jinan, 250012, China
| | - Zonghua Wang
- Department of Prosthodontics, School and Hospital of Stomatology, Cheeloo College of Medicine, Shandong University & Shandong Key Laboratory of Oral Tissue Regeneration & Shandong Engineering Laboratory for Dental Materials and Oral Tissue Regeneration, Jinan, 250012, China
| | - Jiaxin Zhao
- Research Institute of Polymer Materials, School of Materials Science and Engineering, Shandong University, Jinan, 250061, China
| | - Chuanjian Zhou
- Research Institute of Polymer Materials, School of Materials Science and Engineering, Shandong University, Jinan, 250061, China
| | - Junling Wu
- Department of Prosthodontics, School and Hospital of Stomatology, Cheeloo College of Medicine, Shandong University & Shandong Key Laboratory of Oral Tissue Regeneration & Shandong Engineering Laboratory for Dental Materials and Oral Tissue Regeneration, Jinan, 250012, China.
| |
Collapse
|
32
|
Noronha MDS, Fronza BM, André CB, de Castro EF, Soto-Montero J, Price RB, Giannini M. Effect of zirconia decontamination protocols on bond strength and surface wettability. J ESTHET RESTOR DENT 2020; 32:521-529. [PMID: 32598095 DOI: 10.1111/jerd.12615] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Accepted: 06/05/2020] [Indexed: 12/14/2022]
Abstract
OBJECTIVE To evaluate the effects of human saliva decontamination protocols on bond strength of resin cement to zirconia (Y-PSZ), wettability, and microbial decontamination. MATERIALS AND METHODS Zirconia plates were sandblasted and divided into (a) not contaminated, (b) contaminated with human saliva and: (c) not cleaned, (d) cleaned with air-water spray, (e) cleaned with 70% ethanol, (f) cleaned with Ivoclean, or (g) cleaned with nonthermal atmospheric plasma (NTAP). The wettability and microbial decontamination of the surfaces were determined after saliva contamination or cleaning. Monobond Plus (Ivoclar Vivadent) was applied after cleaning, followed by Variolink LC (Ivoclar Vivadent). The samples were stored 1 week before shear bond strength (SBS) testing, and data (SBS and wettability) were analyzed by one-way analysis of variance and Tukey test (α = .05). RESULTS Saliva contamination reduced SBS to zirconia compared to not contaminated. Both Ivoclean and NTAP produced higher SBS compared to not cleaned and were not significantly different from the not contaminated. Ivoclean produced the highest contact angle, and NTAP the lowest. With the exception of using just water-spray, all cleaning protocols decontaminated the specimens. CONCLUSIONS Both Ivoclean and NTAP overcame the effects of saliva contamination, producing an SBS to zirconia comparable to the positive control. CLINICAL SIGNIFICANCE Dental ceramics should be cleaned prior to resin cementation to eliminate the effects of human saliva contamination, and Ivoclean and NTAP are considered suitable materials for this purpose.
Collapse
Affiliation(s)
- Mayara Dos Santos Noronha
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Bruna Marin Fronza
- Department of Biomaterials and Oral Biology, School of Dentistry, University of Sao Paulo, Sao Paulo, SP, Brazil
| | - Carolina Bosso André
- Department of Restorative Dentistry, School of Dentistry, Federal University of Minas Gerais, Belo Horizonte, MG, Brazil
| | - Eduardo Fernandes de Castro
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Jorge Soto-Montero
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil.,Department of Restorative Dentistry, University of Costa Rica - School of Dentistry University, San José, Costa Rica
| | - Richard Bengt Price
- Department of Dental Clinical Sciences, School of Dentistry, Dalhousie University, Halifax, Canada
| | - Marcelo Giannini
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| |
Collapse
|
33
|
Cleaning and Conditioning of Contaminated Core Build-Up Material before Adhesive Bonding. MATERIALS 2020; 13:ma13122880. [PMID: 32604963 PMCID: PMC7344432 DOI: 10.3390/ma13122880] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Revised: 06/20/2020] [Accepted: 06/22/2020] [Indexed: 11/16/2022]
Abstract
The objective of this study was to evaluate the effects of different cleaning and conditioning procedures after contamination on the tensile bond strength (TBS) of a luting resin to a core build-up composite resin. Specimens (n = 384) made of a core build-up material were stored for 3 weeks in 37 °C water. Half of the specimens were contaminated with saliva and a disclosing silicone and then cleaned either using phosphoric acid, a pumice suspension, air-abrasion with alumina or polishing powder. Surface conditioning was performed by either using a dentin adhesive, a silane containing primer or a composite resin primer, which resulted in 24 unique combinations of 16 specimens per group. Before measuring TBS, half of the specimens of each group were stored in 37 °C water for 3d or were artificially aged for 150 days. Results show that cleaning with pumice or air-abrasion are superior methods compared to using a polishing powder or phosphoric acid. Silane is an inferior conditioning agent compared to composite or dentin primers. Ideally, after contamination, bonding surfaces should be cleaned with a pumice suspension and conditioned with a dentin adhesive. Those surfaces could also be cleaned and conditioned with air-abrasion with alumina particles and a composite resin primer.
Collapse
|
34
|
Joukhadar C, Osman E, Rayyan M, Shrebaty M. Comparison between different surface treatment methods on shear bond strength of zirconia ( in vitro study). J Clin Exp Dent 2020; 12:e264-e270. [PMID: 32190197 PMCID: PMC7071543 DOI: 10.4317/jced.56242] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2019] [Accepted: 01/08/2020] [Indexed: 11/05/2022] Open
Abstract
Background To compare the effect of Er:YAG Laser and Air particle abrasion (APA) surface treatments on shear bond strength of Y-TZP to composite resin cuboids in the presence and absence of primer application and salivary contamination. Material and Methods Seventy-two cuboidal shaped specimens 7x7x3 were prepared from Y-TZP using CADCAM, cleaned and sintered. Specimens were divided into 2 main groups (n=36) according to surface treatment method; Air particle abrasion (A) and laser (L). Each group was subdivided into 2 subgroups (N = 18) according to surface modification using primer; each subgroup was further divided into 2 subdivisions (N=9) according to the presence of salivary contamination; APC (Air particle abrasion, primer, contamination), AP (Air particle abrasion, primer), AC (Air particle abrasion, contamination), A (Air particle abrasion), LPC (Laser, primer, contamination), LP (Laser, primer), LC (Laser, contamination), L (Laser). Composite cuboids having dimensions of 6x6x3 were also fabricated using custom made plexi plates. Composite cuboids were cemented centrally to zirconia cuboids and light cured under 5 kg weight for 6 mins. Shear bond strength of specimens was measured utilizing universal testing machine at a crosshead speed of 0.5 mm/min. Failure loads were recorded in Newton. SBS was calculated according to equation: SBS (MPa) = load (N)/area(mm2). Results Viewing shear bond strength between studied groups, group APNC (484.02±85.02) showed higher mean value compared to ANPNC (122.09±55.80), also LNPNC (120.87±65.10) showed higher mean value in comparison to LPNC (170.78±53.22). APNC (484.02±85.02) and APC (592.22±189.65) showed higher mean values than LPNC (170.78±53.22) and LPC (3227.66±108.28) in sequence. Conclusions APA showed higher SBS values than Er:YAG surface treatment. Primer showed better results than no primer coating. Artificial saliva contamination did not affect the SBS of zirconia compared with no contamination results. Key words:Shear bond strength, zirconia, air particle abrasion, Er:YAG laser, primer, contamination.
Collapse
Affiliation(s)
- Christelle Joukhadar
- Clinical Instructor at Faculty of Dentistry, Beirut Arab University, Beirut, Lebanon
| | - Essam Osman
- Professor of Dental Materials, Faculty of Dentistry, Beirut Arab University, Beirut, Lebanon
| | - Mohammad Rayyan
- Professor of Prosthodontics, Faculty of Dentistry, Beirut Arab University, Beirut, Lebanon
| | - Mohammed Shrebaty
- MSC in Fixed prosthodontics, Faculty of Dentistry, Beirut Arab University. Beirut, Lebanon
| |
Collapse
|
35
|
Chen B, Yang L, Lu Z, Meng H, Wu X, Chen C, Xie H. Shear bond strength of zirconia to resin: The effects of specimen preparation and loading procedure. J Adv Prosthodont 2020; 11:313-323. [PMID: 31897270 PMCID: PMC6933049 DOI: 10.4047/jap.2019.11.6.313] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2019] [Revised: 06/16/2019] [Accepted: 12/11/2019] [Indexed: 11/08/2022] Open
Abstract
PURPOSE Shear bond strength (SBS) test is the most commonly used method for evaluating resin bond strength of zirconia, but SBS results vary among different studies even when evaluating the same bonding strategy. The purpose of this study was to promote standardization of the SBS test in evaluating zirconia ceramic bonding and to investigate factors that may affect the SBS value of a zirconia/resin cement/composite resin bonding specimen. MATERIALS AND METHODS The zirconia/resin cement/composite resin bonding specimens were used to simulate loading with a shear force by the three-dimensional finite element (3D FE) modeling, in which stress distribution under uniform/non-uniform load, and different resin cement thickness and different elastic modulus of resin composite were analyzed. In vitro SBS test was also performed to validate the results of 3D FE analysis. RESULTS The loading flat width was an important affecting factor. 3D FE analysis also showed that differences in resin cement layer thickness and resin composite would lead to the variations of stress accumulation area. The SBS test result showed that the load for preparing a SBS specimen is negatively correlated with the resin cement thickness and positively correlated with SBS values. CONCLUSION When preparing a SBS specimen for evaluating bond performance, the load flat width, the load applied during cementation, and the different composite resins used affect the SBS results and therefore should be standardized.
Collapse
Affiliation(s)
- Bingzhuo Chen
- Jiangsu Key Laboratory of Oral Diseases, Nanjing Medical University; Department of Prosthodontics, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, China
| | - Lu Yang
- Jiangsu Key Laboratory of Oral Diseases, Nanjing Medical University; Department of Prosthodontics, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, China
| | - Zhicen Lu
- Jiangsu Key Laboratory of Oral Diseases, Nanjing Medical University; Department of Prosthodontics, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, China
| | - Hongliang Meng
- Jiangsu Key Laboratory of Oral Diseases, Nanjing Medical University; Department of Prosthodontics, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, China
| | - Xinyi Wu
- Jiangsu Key Laboratory of Oral Diseases, Nanjing Medical University; Department of Endodontics, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, China
| | - Chen Chen
- Jiangsu Key Laboratory of Oral Diseases, Nanjing Medical University; Department of Endodontics, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, China
| | - Haifeng Xie
- Jiangsu Key Laboratory of Oral Diseases, Nanjing Medical University; Department of Prosthodontics, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing, China
| |
Collapse
|
36
|
Güers P, Wille S, Strunskus T, Polonskyi O, Kern M. Durability of resin bonding to zirconia ceramic after contamination and the use of various cleaning methods. Dent Mater 2019; 35:1388-1396. [PMID: 31447058 DOI: 10.1016/j.dental.2019.07.027] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2019] [Revised: 06/18/2019] [Accepted: 07/15/2019] [Indexed: 11/15/2022]
Abstract
OBJECTIVES The aim of the study was to evaluate the influence of contamination and different cleaning methods on the tensile bond strength with a phosphate monomer containing luting resin to zirconia ceramic. METHODS After the contamination with saliva or silicone disclosing agent, 228 polished and airborne-particle abraded zirconia discs were ultrasonically cleaned with 99% isopropanol. In a second step, the specimens were either treated with argon-oxygen plasma, air plasma, enzymatic cleaning agent or did not undergo an additional cleaning process. Uncontaminated zirconia specimens were used as the control group. X-ray photoelectron spectroscopy (XPS) was used for chemical analysis of the bonding surfaces of specimens. Plexiglas tubes filled with composite resin were bonded to zirconia specimens with a phosphate monomer containing luting resin. Tensile bond strength (TBS) was tested after 3 days or 150 days water storage with 37,500 thermal cycles. RESULTS XPS revealed a decrease of the carbon/oxygen ratio after plasma treatment and an increase after treatment with an enzymatic cleaning agent in all groups. All contaminated specimens showed high and durable TBS after cleaning with a combination of isopropanol and a non-thermal atmospheric plasma. After the cleaning with enzymatic cleaning agent the TBS was significantly reduced in all groups after 150 days thermal cycling. SIGNIFICANCE The combination of isopropanol and plasma cleaning was effective in removing salvia and disclosing agent contamination. Enzymatic clearing agent was not able to remove contamination effectively and had a negative impact on the TBS of non-contaminated specimens.
Collapse
Affiliation(s)
- Philipp Güers
- Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian-Albrechts University at Kiel, Arnold-Heller-Str. 16, 24105 Kiel, Germany.
| | - Sebastian Wille
- Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian-Albrechts University at Kiel, Arnold-Heller-Str. 16, 24105 Kiel, Germany.
| | - Thomas Strunskus
- Institute for Materials Science, Faculty of Engineering, Christian-Albrechts University at Kiel, Kaiserstr. 2, 24143 Kiel, Germany.
| | - Oleksandr Polonskyi
- Institute for Materials Science, Faculty of Engineering, Christian-Albrechts University at Kiel, Kaiserstr. 2, 24143 Kiel, Germany.
| | - Matthias Kern
- Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian-Albrechts University at Kiel, Arnold-Heller-Str. 16, 24105 Kiel, Germany.
| |
Collapse
|
37
|
Zhao P, Yu P, Xiong Y, Yue L, Arola D, Gao S. Does the bond strength of highly translucent zirconia show a different dependence on the airborne-particle abrasion parameters in comparison to conventional zirconia? J Prosthodont Res 2019; 64:60-70. [PMID: 31395520 DOI: 10.1016/j.jpor.2019.04.008] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2018] [Revised: 03/11/2019] [Accepted: 04/17/2019] [Indexed: 02/05/2023]
Abstract
PURPOSE To compare the effects of airborne-particle abrasion protocols on the surface morphology, the phase transformation and the resin bond strength of highly translucent zirconia (M) and conventional zirconia (Z). METHODS Thirteen groups (N = 12) of Z and M specimens were prepared. Except for the control group, the specimens were sandblasted with conditions involving different grit sizes (50 μm or 110 μm), treatment times (10 s or 20 s) and pressures (0.1 MPa, 0.3 MPa or 0.6 MPa). The surface morphology was analyzed using scanning electron microscope (SEM) and the phase analysis was conducted with X-ray diffraction (XRD). The Ra and the shear bond strength (SBS) were measured and statistically analyzed, and the failure mode was determined by optical microscope. RESULTS The surface morphologies were strongly dependent on treatment conditions. Larger particle size and higher pressure resulted in higher Ra for both materials. Longer blasting time resulted in higher Ra for Z but not M. Overall, the SBS increased with increasing Ra; the highest average SBS was achieved by M and exceeded 18 MPa. The monoclinic transformation was not found in any treatment for M, but was found in Z. CONCLUSIONS Z and M showed different dependence on the airborne-particle abrasion parameters in terms of Ra, SBS and phase transformation. The conditions for maximizing SBS included a 110 μm particle size and 20 s treatment for both, with pressures of 0.3 MPa and 0.6 MPa for the M and Z, respectively.
Collapse
Affiliation(s)
- Peng Zhao
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Ping Yu
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Yuhuan Xiong
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Li Yue
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Dwayne Arola
- Department of Materials Science and Engineering, University of Washington, Seattle, WA, USA; Departments of Oral Health Sciences, School of Dentistry, University of Washington, Seattle, WA, USA; Departments of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, WA, USA
| | - Shanshan Gao
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China.
| |
Collapse
|
38
|
Wattanasirmkit K, Charasseangpaisarn T. Effect of different cleansing agents and adhesive resins on bond strength of contaminated zirconia. J Prosthodont Res 2019; 63:271-276. [DOI: 10.1016/j.jpor.2018.12.007] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2018] [Revised: 12/07/2018] [Accepted: 12/12/2018] [Indexed: 11/16/2022]
|
39
|
Samran A, Al-Ammari A, El Bahra S, Halboub E, Wille S, Kern M. Bond strength durability of self-adhesive resin cements to zirconia ceramic: An in vitro study. J Prosthet Dent 2019; 121:477-484. [DOI: 10.1016/j.prosdent.2018.03.026] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2017] [Revised: 03/17/2018] [Accepted: 03/19/2018] [Indexed: 10/27/2022]
|
40
|
Lapinska B, Rogowski J, Nowak J, Nissan J, Sokolowski J, Lukomska-Szymanska M. Effect of Surface Cleaning Regimen on Glass Ceramic Bond Strength. Molecules 2019; 24:molecules24030389. [PMID: 30678247 PMCID: PMC6385042 DOI: 10.3390/molecules24030389] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2018] [Revised: 01/17/2019] [Accepted: 01/20/2019] [Indexed: 01/30/2023] Open
Abstract
This study investigated the effect of saliva contamination on chemical changes of ceramic surface as well as the influence of saliva cleaning methods on ceramic-resin bond strength. Saliva was used to contaminate leucite (LGC) and lithium disilicate (LDGC) glass ceramic surfaces. The following cleaning methods were tested: water spray, cleaning with orthophosphoric acid, universal cleaning paste, ultrasonic cleaning with water, re-etching with hydrofluoric acid. Non-contaminated ceramic sample served as control. Chemical analysis of ceramic surfaces was performed using time-of-flight secondary ion mass spectrometry (TOF-SIMS). Shear bond strength (SBS) of ceramics to resin material was tested after 24-hour water storage and after thermocycling. The most effective cleaning method of saliva-contaminated ceramic surface was cleaning LGC surface with orthophosphoric acid or re-etching the LDGC surface with hydrofluoric acid. The application of the following methods resulted in obtaining reliable bond strength.
Collapse
Affiliation(s)
- Barbara Lapinska
- Department of General Dentistry, Medical University of Lodz, 251 Pomorska St., 92-213 Lodz, Poland.
| | - Jacek Rogowski
- Institute of General and Ecological Chemistry, Lodz University of Technology, 116 Zeromskiego St., 90-924 Lodz, Poland.
| | - Joanna Nowak
- University Laboratory of Materials Research, Medical University of Lodz, 251 Pomorska St., 92-213 Lodz, Poland.
| | - Joseph Nissan
- Department of Oral Rehabilitation, School of Dental Medicine, Tel Aviv University, 6997801 Tel Aviv, Israel.
| | - Jerzy Sokolowski
- Department of General Dentistry, Medical University of Lodz, 251 Pomorska St., 92-213 Lodz, Poland.
| | | |
Collapse
|
41
|
|
42
|
BLANC KGNF, CARVALHO DTD, ELIAS CN. Influência do método de limpeza da zircônia na adesão da prótese após a contaminação com saliva. REVISTA DE ODONTOLOGIA DA UNESP 2019. [DOI: 10.1590/1807-2577.06819] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Resumo Introdução A contaminação das restaurações de zircônia com saliva antes da cimentação influencia na resistência da adesão face à afinidade com os íons da saliva. Objetivo Analisar os métodos de limpeza da zircônia na adesão à dentina após a contaminação com saliva. Material e método Oitenta amostras de zircônia com dimensão 4×11×3 mm foram cortadas de blocos pré-sinterizados (3Y-TZP, In-Ceram - VITA) e sinterizadas. Após a sinterização, as amostras foram jateadas com partículas de óxido de alumínio, lavadas em água destilada e divididas em dois grupos com base no tipo de cimento de adesão: RelyX U200 Clicker® (grupo R) ou Multilink N® (grupo M). As amostras foram divididas em quatro subgrupos (n=10) de acordo com os métodos de limpeza e com o tipo de cimento: RG1 e MGI (sem contaminação com saliva); RG2 e MG2 (sem contaminação e limpeza com Ivoclean®); RG3 e MG3 (com contaminação e limpeza com água); RG4 e MG4 (com contaminação e limpeza com Ivoclean®). Após a cimentação, as amostras foram armazenadas em água por 10 dias. A resistência da adesão foi determinada pelo teste de cisalhamento. Resultado Os resultados mostraram que a maior e a menor resistência foram do Grupo RG2 e MG2, respectivamente. Entre as amostras cimentadas com RelyXTM, somente o grupo RG4 apresentou diferença na resistência da adesão (p=0,018) em relação aos demais subgrupos. Entre os grupos cimentados com Multilink N®, não houve diferença estatística (p>0,05) na resistência. Conclusão Os resultados mostraram que o agente de limpeza Ivoclean® não foi efetivo na descontaminação e não influenciou na resistência ao cisalhamento.
Collapse
|
43
|
Elias AB, Simão RA, Prado M, Cesar PF, Botelho Dos Santos G, Moreira da Silva E. Effect of different times of nonthermal argon plasma treatment on the microtensile bond strength of self-adhesive resin cement to yttria-stabilized tetragonal zirconia polycrystal ceramic. J Prosthet Dent 2018; 121:485-491. [PMID: 30409721 DOI: 10.1016/j.prosdent.2018.03.025] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2017] [Revised: 03/21/2018] [Accepted: 03/22/2018] [Indexed: 11/25/2022]
Abstract
STATEMENT OF PROBLEM Nonthermal argon plasma may increase the surface energy of yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) dental ceramics. However, studies that evaluated the effect of increased plasma treatment times on the bond strength of resin cements to Y-TZP ceramics are lacking. PURPOSE The purpose of this in vitro study was to evaluate the effect of different nonthermal argon plasma (NTAP) treatment times on the surface energy and bond strength of a self-adhesive resin cement to Y-TZP ceramic. MATERIAL AND METHODS Forty-eighty Y-TZP plates were divided into 2 groups (n=24): as-sintered (AS) and airborne-particle abrasion (APA) with 50-μm Al2O3, which were subdivided into 4 groups (n=6) according to the time of NTAP treatment: 0, 20, 60, and 120 seconds. The surface energy was evaluated with a goniometer. Forty Y-TZP blocks submitted to the same surface treatments (8 groups; n=5) were cemented to composite resin blocks, using a self-adhesive resin cement. After storage in distilled water at 37°C for 24 hours, the Y-TZP-composite resin blocks were cut into beams and submitted to a microtensile bond strength (μTBS) test. Data were analyzed using 2-way ANOVA and the Tukey honestly significant differences test (α=.05). RESULTS Treatment with NTAP increased the surface energy for AS and APA groups (P<.05). For both groups, the μTBS was as follows: 0 seconds < 20 seconds < 60 seconds = 120 seconds (P<.05). Only after 120 seconds of NTAP treatment was the μTBS of APA higher than that of AS (P<.05). CONCLUSIONS Treatment with NTAP improved the surface energy and increased the μTBS of self-adhesive resin cement to Y-TZP ceramic, with higher times of plasma treatment resulting in higher bond strength.
Collapse
Affiliation(s)
- Alexandre Barboza Elias
- Adjunct Professor, Analytical Laboratory of Restorative Biomaterials, LABiom-R, School of Dentistry, Federal Fluminense University, Rio de Janeiro, Brazil
| | - Renata Antoun Simão
- Associate Professor Laboratory of Polymer and Asphalt Surfaces, School of Metallurgical and Materials Engineering, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Maíra Prado
- Associate Researcher, Laboratory of Polymer and Asphalt Surfaces, School of Metallurgical and Materials Engineering, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Paulo Francisco Cesar
- Associate Professor, Department of Biomaterials and Oral Biology, School of Dentistry, University of São Paulo (USP), São Paulo, Brazil
| | - Glauco Botelho Dos Santos
- Adjunct Professor, Analytical Laboratory of Restorative Biomaterials, LABiom-R, School of Dentistry, Federal Fluminense University, Rio de Janeiro, Brazil
| | - Eduardo Moreira da Silva
- Associate Professor, Analytical Laboratory of Restorative Biomaterials, LABiom-R, School of Dentistry, Federal Fluminense University, Rio de Janeiro, Brazil.
| |
Collapse
|
44
|
Irmak Ö, Yaman BC, Orhan EO, Kılıçarslan MA, Mante FK, Ozer F. Influence of cleaning methods on bond strength to saliva contaminated zirconia. J ESTHET RESTOR DENT 2018; 30:551-556. [DOI: 10.1111/jerd.12416] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2018] [Revised: 05/16/2018] [Accepted: 06/25/2018] [Indexed: 11/30/2022]
Affiliation(s)
- Özgür Irmak
- Eskişehir Osmangazi University; Faculty of Dentistry, Department of Restorative Dentistry; Eskişehir Turkey
| | - Batu Can Yaman
- Eskişehir Osmangazi University; Faculty of Dentistry, Department of Restorative Dentistry; Eskişehir Turkey
| | - Ekim Onur Orhan
- Eskişehir Osmangazi University; Faculty of Dentistry, Department of Endodontics; Eskişehir Turkey
| | - Mehmet Ali Kılıçarslan
- Ankara University; Faculty of Dentistry, Department of Prosthetic Dentistry; Ankara Turkey
| | - Francis K. Mante
- Department of Preventive and Restorative Sciences; School of Dental Medicine, University of Pennsylvania; Philadelphia Pennsylvania
| | - Fusun Ozer
- Department of Preventive and Restorative Sciences; School of Dental Medicine, University of Pennsylvania; Philadelphia Pennsylvania
| |
Collapse
|
45
|
Takahashi A, Takagaki T, Wada T, Uo M, Nikaido T, Tagami J. The effect of different cleaning agents on saliva contamination for bonding performance of zirconia ceramics. Dent Mater J 2018; 37:734-739. [PMID: 30047509 DOI: 10.4012/dmj.2017-376] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The effects of contamination and cleaning methods on bonding of self-adhesive resin cement to zirconia ceramics were examined. Airborne particle-abraded zirconia (Zpex Smile) specimens were divided into the following four groups: control (con), contaminated with saliva and cleaned with tap water (HS), cleaned with Ivoclean (IC), and cleaned with Multi Etchant (ME). The pretreated specimens were bonded using three self-adhesive resin cements, and tensile bond strengths were measured using a universal testing machine at a crosshead speed of 2 mm/min. Con and IC groups showed significantly higher bond strength than those of HS and ME groups. Separately, the surface chemical composition of the groups was determined using X-ray photoelectron spectroscopy (XPS). XPS revealed that the N/Zr ratio increased in the HS group but decreased in the IC and ME groups. Cleaning agents can improve the adverse effect of saliva contamination on zirconia, but this effect varies depending on the product.
Collapse
Affiliation(s)
- Akifumi Takahashi
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Tomohiro Takagaki
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Takahiro Wada
- Department of Advanced Biomaterials, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Motohiro Uo
- Department of Advanced Biomaterials, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Toru Nikaido
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Junji Tagami
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| |
Collapse
|
46
|
Effect of saliva contamination and artificial aging on different primer/cement systems bonded to zirconia. J Prosthet Dent 2018; 119:833-839. [DOI: 10.1016/j.prosdent.2017.07.006] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2017] [Revised: 07/10/2017] [Accepted: 07/10/2017] [Indexed: 11/21/2022]
|
47
|
Nejatidanesh F, Savabi O, Savabi G, Razavi M. Effect of cleaning methods on retentive values of saliva-contaminated implant-supported zirconia copings. Clin Oral Implants Res 2018; 29:530-536. [PMID: 29656421 DOI: 10.1111/clr.13150] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/19/2018] [Indexed: 11/29/2022]
Abstract
OBJECTIVE The aim of this study was to evaluate the effect of different cleaning regimens on retentive strength of saliva-contaminated implant-supported zirconia copings. MATERIAL AND METHODS Seventy solid titanium abutments with 5.5 mm height (Straumann) were attached to the regular neck implant analogs (Straumann). The abutment-analog complex was mounted vertically in an autopolymerized T-shaped acrylic resin block. Seventy zirconia copings with an occlusal loop were made. The copings were contaminated with fresh human saliva for 1 min (except the control group). Afterward, the specimens were washed with water spray for 15 s and dried for 15 s. The copings were divided into seven groups according to cleaning methods (n = 10). Group 1: no contamination (control group); Group 2: water spray rinsing; Group 3: airborne particle abrasion; Group 4: immersion in 96% isopropanol; Group 5: applying Ivoclean (Ivoclar Vivadent); Group 6: applying 1% sodium hypochlorite; and Group 7: applying Monobond Plus (Ivoclar Vivadent). The copings were luted with a resin luting agent (RelyX Unicem; 3M ESPE). After 5,000 thermal cycles, the retentive values of the restorations were tested using universal testing machine. The dislodging forces were analyzed using one-way analysis of variance and the Tukey's HSD tests (α = 0.05). RESULTS The copings, which were cleaned with Ivoclean and 96% isopropanol, showed the highest retentive values (204.79 ± 44.49 and 232.65 ± 71.36, respectively). There was a significant difference between the studied groups (F = 2.735; p = .02). Tukey's HSD showed that there was no significant difference between the different cleaning procedures and control group except water rinsing group (p = .14). The lowest retentive value was related to the saliva-contaminated group, which were only cleaned with water rinsing method. CONCLUSION The retentive values of zirconia-based restorations were adversely affected by saliva contaminations. These restorations can be cleaned by Ivoclean, 96% isopropanol, airborne particle abrasion, 1% sodium hypochlorite, or applying Monobond Plus before luting procedures.
Collapse
Affiliation(s)
- Farahnaz Nejatidanesh
- Dental Materials Research Center, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran.,Department of Prosthodontics, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Omid Savabi
- Dental Research Center, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Ghazal Savabi
- Dental Materials Research Center, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Mehdi Razavi
- Department of Radiology, School of Medicine, Stanford University, Stanford, CA, USA
| |
Collapse
|
48
|
Yoshida K. Influence of cleaning methods on resin bonding to saliva-contaminated zirconia. J ESTHET RESTOR DENT 2018; 30:259-264. [DOI: 10.1111/jerd.12369] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Affiliation(s)
- Keiichi Yoshida
- Clinic of Fixed Prosthodontics, Nagasaki University Hospital; Nagasaki Japan
- Department of Applied Prosthodontics; Graduate School of Biomedical Sciences, Nagasaki University; Nagasaki Japan
| |
Collapse
|
49
|
Lee JH. Guided tooth preparation for a pediatric zirconia crown. J Am Dent Assoc 2018; 149:202-208.e2. [PMID: 29395008 DOI: 10.1016/j.adaj.2017.08.048] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2017] [Revised: 07/25/2017] [Accepted: 08/30/2017] [Indexed: 10/18/2022]
Abstract
BACKGROUND AND OVERVIEW Unesthetic primary incisors can produce negative self-perceptions in preschool-aged children. In recent years, because of increased esthetic demands, prefabricated zirconia crowns have become increasingly popular. However, zirconia crowns cannot be crimped, and the clinician must prepare the teeth to fit the zirconia crowns. Therefore, extended preparation and fitting times are necessary, especially for inexperienced practitioners. A 1- to 2-millimeter subgingival feather margin also is required. Gingival hemorrhage after subgingival preparation compromises the retention of zirconia crowns. CASE DESCRIPTION In this clinical report, the author presents a step-by-step description of the clinical and laboratory procedures for restoring a discolored traumatized incisor with a zirconia crown. The author used a polyvinyl siloxane occlusal registration material as an impression material and made 2 identical casts. The author fabricated 3 reduction guides after prospective tooth preparation on the casts. The author rapidly prepared the discolored incisor with the reduction guides and ultrasonic burs. A zirconia crown provided an optimal esthetic result and gingival health. CONCLUSIONS AND PRACTICAL IMPLICATIONS Because the reduction guides provided a visibility intraorally, fast tooth reduction, less trial placement, and passive adaptation of the crown were successful. Because the ultrasonic burs prevented gingival injuries, hemorrhage control was not necessary. The presented technique reduced the patient's discomfort and total chair time. Therefore, this alternative technique is helpful for inexperienced practitioners.
Collapse
|
50
|
Krifka S, Preis V, Rosentritt M. Effect of Decontamination and Cleaning on the Shear Bond Strength of High Translucency Zirconia. Dent J (Basel) 2017; 5:dj5040032. [PMID: 29563438 PMCID: PMC5806969 DOI: 10.3390/dj5040032] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2017] [Revised: 10/30/2017] [Accepted: 11/09/2017] [Indexed: 11/21/2022] Open
Abstract
(1) Background: This study evaluated the bonding performance of high translucency zirconia after diverse surficial decontamination and cleaning procedures. (2) Methods: High translucency zirconia (LavaTM Esthetic) specimens (2.0 mm × 20 mm × 10 mm) were exposed to different surface treatments prior to bonding to CoCr cylinders (d = 5 mm, height = 3 mm). All surfaces were sandblasted (40 µm aluminum oxide, 2 bar) and treated with alcohol (al), saliva (s), saliva + water (sw), or saliva + NaOCl + water (sn) before bonding was performed with the following adhesive luting systems: RelyXTM Unicem 2 (RX), ScotchbondTM Universal (SBU) + RelyXTM Ultimate (RU) or Monobond Plus (MP) + Multilink® Automix (ML). After 24 h, thermocycling (TC:12,000 × 5 °C/55 °C) and 90 days of storage at 37 °C in distilled water, the shear bond strength (SBS) was evaluated according to ISO/TS 11,405:2015. Failure modes along bonding areas were characterized. Means and standard deviations (n = 10 per group) were determined and statistically analyzed with one-way ANOVA/Bonferroni (α = 0.05). (3) Results: The SBS after 24 h varied between 3.5 (sRX) and 69.4 MPa (snMP + ML). Values from 0 (sRX) to 70.3 MPa (swRX) were found after TC. Data after 90 days of storage showed the lowest values for sRX (0 MPa) and the highest values for alSBU + RU (75.5 MPa). Adhesive failure was noted at all aging conditions. (4) Conclusions: SBU + RU or RX and MP + ML including saliva decontamination of the ceramic surface with water or NaOCl + water allow efficient bonding to LavaTM Esthetic.
Collapse
Affiliation(s)
- Stephanie Krifka
- Department of Prosthetic Dentistry, University Hospital Regensburg, 93051 Regensburg, Germany.
| | - Verena Preis
- Department of Prosthetic Dentistry, University Hospital Regensburg, 93051 Regensburg, Germany.
| | - Martin Rosentritt
- Department of Prosthetic Dentistry, University Hospital Regensburg, 93051 Regensburg, Germany.
| |
Collapse
|