1
|
Arakelyan M, Spagnuolo G, Iaculli F, Dikopova N, Antoshin A, Timashev P, Turkina A. Minimization of Adverse Effects Associated with Dental Alloys. MATERIALS (BASEL, SWITZERLAND) 2022; 15:7476. [PMID: 36363067 PMCID: PMC9658402 DOI: 10.3390/ma15217476] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Revised: 10/17/2022] [Accepted: 10/21/2022] [Indexed: 06/16/2023]
Abstract
Metal alloys are one of the most popular materials used in current dental practice. In the oral cavity, metal structures are exposed to various mechanical and chemical factors. Consequently, metal ions are released into the oral fluid, which may negatively affect the surrounding tissues and even internal organs. Adverse effects associated with metallic oral appliances may have various local and systemic manifestations, such as mouth burning, potentially malignant oral lesions, and local or systemic hypersensitivity. However, clear diagnostic criteria and treatment guidelines for adverse effects associated with dental alloys have not been developed yet. The present comprehensive literature review aims (1) to summarize the current information related to possible side effects of metallic oral appliances; (2) to analyze the risk factors aggravating the negative effects of dental alloys; and (3) to develop recommendations for diagnosis, management, and prevention of pathological conditions associated with metallic oral appliances.
Collapse
Affiliation(s)
- Marianna Arakelyan
- Therapeutic Dentistry Department, Institute for Dentistry, Sechenov University, 119991 Moscow, Russia
| | - Gianrico Spagnuolo
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples “Federico II”, 80138 Napoli, Italy
| | - Flavia Iaculli
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples “Federico II”, 80138 Napoli, Italy
| | - Natalya Dikopova
- Therapeutic Dentistry Department, Institute for Dentistry, Sechenov University, 119991 Moscow, Russia
| | - Artem Antoshin
- Institute for Regenerative Medicine, Sechenov University, 119991 Moscow, Russia
- World-Class Research Center “Digital Biodesign and Personalized Healthcare”, Sechenov University, 119991 Moscow, Russia
| | - Peter Timashev
- Institute for Regenerative Medicine, Sechenov University, 119991 Moscow, Russia
- World-Class Research Center “Digital Biodesign and Personalized Healthcare”, Sechenov University, 119991 Moscow, Russia
- Chemistry Department, Lomonosov Moscow State University, 119234 Moscow, Russia
| | - Anna Turkina
- Therapeutic Dentistry Department, Institute for Dentistry, Sechenov University, 119991 Moscow, Russia
| |
Collapse
|
2
|
Ismail HS, Ali AI, Garcia-Godoy F. In vitro biocompatibility testing of different base materials used for elevation of proximal subgingival margins using human gingival epithelial cells. J Oral Sci 2022; 64:118-123. [PMID: 35173097 DOI: 10.2334/josnusd.21-0393] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Abstract
PURPOSE To analyze the biological effects of four base materials used for elevation of proximal subgingival margins on gingival epithelial cells. METHODS Twenty-eight specimens for each of the four base materials (total 112 specimens) were used: resin-modified glass ionomer (RMGI), glass hybrid (HV-GIC), flowable bulk fill resin composite (Bulk Flow) and bioactive ionic resin (Activa). Proximal enamel and root dentin were used as controls. Gingival epithelial cell viability was calculated after direct incubation on all four types of material for either 24 h or 72 h using both the methyl tetrazolium and trypan blue dye exclusion assays. Data were analyzed statistically using one-way analysis of variance, Tukey post hoc test and independent sample t-test (P < 0.05). RESULTS Cell viability values in both assays showed significant differences among the study groups. Bulk Flow showed the highest values, followed in order by Activa and the control groups. Both HV-GIC and RMGI had the lowest values. Cell viability in all of the study groups was higher after incubation for 72 h than after 24 h. CONCLUSION In terms of biocompatibility with epithelial tissues, bulk fill resin composite appears to be most suitable, followed by bioactive composite, for subgingival placement than glass ionomer-based materials, especially that containing 2-hydroxy-ethyl methacrylate.
Collapse
Affiliation(s)
- Hoda S Ismail
- Operative Dentistry Department, Faculty of Dentistry, Mansoura University
| | - Ashraf I Ali
- Operative Dentistry Department, Faculty of Dentistry, Mansoura University
| | - Franklin Garcia-Godoy
- Department of Bioscience Research, College of Dentistry, University of Tennessee Health Science Center.,The Forsyth Institute
| |
Collapse
|
3
|
Brewed Robusta Coffee Increases Nickel Ion Release from Dental Alloys: An In Vitro Study. MATERIALS 2021; 14:ma14227069. [PMID: 34832471 PMCID: PMC8620205 DOI: 10.3390/ma14227069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/13/2021] [Revised: 11/17/2021] [Accepted: 11/18/2021] [Indexed: 11/25/2022]
Abstract
Alloys in oral cavity always interact with dynamic oral environment, such as pH, temperature, salivary conditions, and dietary habits. Coffee can further decrease pH in the oral cavity. Thus, coffee may increase the release of metal ions that may lead to various health diseases. This study aimed to quantitively investigate the effect of brewed Robusta coffee on the nickel ion release and their morphological structures; Methods: 20 alloy specimens were divided into 4 groups and placed in solutions for 48 and 168 h: (1) distilled water, (2) artificial saliva, (3) Robusta coffee, and (4) mixture of artificial saliva and Robusta coffee. AAS, XRF, and SEM were used for examinations; Results: The release of Ni2+ was found in all groups and robust release were found in the coffee only and mixture of coffee + artificial saliva solution after 168 h. Likewise, SEM showed that internal oxidation was high after 168 h of immersion; Conclusions: The concentration of nickel increased in saliva of low pH due to brewed coffee. Though the release of these ions is still within the tolerable amount in human body, it should be realized that it usually lasts for months or years. Dentists should be cautious when using instructions for patients with a history of allergies especially for dietary with low acidity.
Collapse
|
4
|
Mat-Baharin NH, Razali M, Mohd-Said S, Syarif J, Muchtar A. Influence of alloying elements on cellular response and in-vitro corrosion behavior of titanium-molybdenum-chromium alloys for implant materials. J Prosthodont Res 2020; 64:490-497. [DOI: 10.1016/j.jpor.2020.01.004] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2019] [Revised: 01/08/2020] [Accepted: 01/17/2020] [Indexed: 11/17/2022]
|
5
|
Moslehifard E, Ghaffari T, Mohammadian-Navid S, Ghafari-Nia M, Farmani A, Nasirpouri F. Effect of chemical passivation on corrosion behavior and ion release of a commercial chromium-cobalt alloy. J Dent Res Dent Clin Dent Prospects 2020; 14:171-176. [PMID: 33408822 PMCID: PMC7770396 DOI: 10.34172/joddd.2020.037] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Accepted: 08/06/2020] [Indexed: 11/09/2022] Open
Abstract
Background. Corrosion resistance and ion release of alloys play a crucial role in biomedical applications. The present study aimed to investigate an increase in corrosion resistance and reduction in ion release in a commercial Co-Cr-Mo alloy by the chemical passivation method. Methods. Based on ADA97, 20 samples of Flexicast alloy were cast, surface-polished, and electrolytically passivated at room temperature for 24 h in a sodium sulfate solution. Corrosion and ion release of the alloys before and after passivation were studied in normal saline solution. Corrosion resistance and the ion release rates were measured by the weight loss method and atomic absorption spectroscopy, respectively, before and after passivation after 1, 2, 3, and 4 weeks. The surface morphology of the samples was examined using scanning electron microscopy (SEM). The results were analyzed with Kruskal-Wallis and Mann-Whitney tests using SPSS 20 at a significance level of <0.05. Results. The corrosion rate in the passivated samples was significantly lower than the non-passivated samples at the intervals (1, 2, 3, and 4 weeks) (P<0.05). The passivation of the alloy significantly reduced Co and Cr ion release in the first and fourth weeks, and in the first, second, and fourth weeks, respectively (P<0.05). SEM images revealed localized pitting associated with the corrosion, which was less significant in passivated samples. Conclusion. Chemical passivation of the CR-Co alloy significantly reduced corrosion and ionic release of Cr and Co over time.
Collapse
Affiliation(s)
- Elnaz Moslehifard
- Department of Prosthodontics, Faculty of Dentistry, Tabriz University of Medical Science, Tabriz, Iran
| | - Tahereh Ghaffari
- Department of Prosthodontics, Faculty of Dentistry, Tabriz University of Medical Science, Tabriz, Iran
| | | | | | - Amirali Farmani
- Faculty of Materials Engineering, Sahand University of Technology, Tabriz, Iran
| | - Farzad Nasirpouri
- Faculty of Materials Engineering, Sahand University of Technology, Tabriz, Iran
| |
Collapse
|
6
|
Su F, Wang Y, Liu X, Shen X, Zhang X, Xing Q, Wang L, Chen Y. Biocompatibility and in vivo degradation of chitosan based hydrogels as potential drug carrier. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2018; 29:1515-1528. [PMID: 29745306 DOI: 10.1080/09205063.2017.1412244] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Carboxymethyl chitosan-graft-polylactide (CMCS-PLA) and carboxymethyl chitosan (CMCS) hydrogels were prepared by using 1-(3-dimethylaminopropyl)-3-ethylcarbodiimide hydrochloride/N-hydroxysuccinimide (EDC/NHS) as crosslinking agent and catalyst at room temperature. The biocompatibility of the hydrogels was evaluated with the aim of assessing their potential as drug carrier. Various aspects of biocompatibility were considered, including MTT assay, agar diffusion test, release of lactate dehydrogenase (LDH), hemolytic test, plasma recalcification time (PRT), and dynamic clotting time. MTT assay showed that the cytotoxicity level of both hydrogels to L-929 cells was 0 or 1. The LDH release of CMCS and CMCS-PLA was 26 and 29%, respectively, which is slightly higher than that of the negative control (21%) and much lower than that of the negative control (87%). The hemolysis ratio of CMCS and CMCS-PLA was 1.4 and 1.7%, respectively, suggesting outstanding anti-hemolysis properties of both materials. The PRT value of CMCS and CMCS-PLA was higher by 77 and 99% than the value of the positive control. All the results revealed that the hydrogels present good cytocompatibility and hemocompatibility in vitro. In vivo degradation and tissue compatibility were evaluated by subcutaneous injection in the dorsal area of rats. CMCS and CMCS-PLA hydrogels were completely degraded and the inflammatory response also completely disappeared around hydrogels after 19 days in vivo. It is thus concluded that hydrogels formed of CMCS and CMCS-PLA with outstanding biocompatibility are promising as potential drug carrier.
Collapse
Affiliation(s)
- Feng Su
- a College of Chemical Engineering , Qingdao University of Science and Technology , Qingdao , China.,b Institute of High Performance Polymers , Qingdao University of Science and Technology , Qingdao , China
| | - Yuandou Wang
- b Institute of High Performance Polymers , Qingdao University of Science and Technology , Qingdao , China
| | - Xue Liu
- a College of Chemical Engineering , Qingdao University of Science and Technology , Qingdao , China
| | - Xin Shen
- b Institute of High Performance Polymers , Qingdao University of Science and Technology , Qingdao , China
| | - Xingjian Zhang
- c Heart Center, Qingdao Women and Children's Hospital , Qingdao University , Qingdao , China
| | - Quansheng Xing
- c Heart Center, Qingdao Women and Children's Hospital , Qingdao University , Qingdao , China
| | - Lihong Wang
- a College of Chemical Engineering , Qingdao University of Science and Technology , Qingdao , China
| | - Yangsheng Chen
- d Qingdao Chiatai HAIER Pharmaceutical Co., LTD. , Qingdao , China
| |
Collapse
|
7
|
ALGhanem A, Fernandes G, Visser M, Dziak R, Renné WG, Sabatini C. Biocompatibility and bond degradation of poly-acrylic acid coated copper iodide-adhesives. Dent Mater 2017; 33:e336-e347. [PMID: 28712739 DOI: 10.1016/j.dental.2017.06.010] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2017] [Revised: 05/13/2017] [Accepted: 06/13/2017] [Indexed: 01/15/2023]
Abstract
OBJECTIVE To investigate the effect of poly-acrylic acid (PAA) copper iodide (CuI) adhesives on bond degradation, tensile strength, and biocompatibility. METHODS PAA-CuI particles were incorporated into Optibond XTR, Optibond Solo and XP Bond in 0.1 and 0.5mg/ml. Clearfil SE Protect, an MDPB-containing adhesive, was used as control. The adhesives were applied to human dentin, polymerized and restored with composite in 2mm-increments. Resin-dentin beams (0.9±0.1mm2) were evaluated for micro-tensile bond strength after 24h, 6 months and 1year. Hourglass specimens (10×2×1mm) were evaluated for ultimate tensile strength (UTS). Cell metabolic function of human gingival fibroblast cells exposed to adhesive discs (8×1mm) was assessed with MTT assay. Copper release from adhesive discs (5×1mm) was evaluated with UV-vis spectrophotometer after immersion in 0.9% NaCl for 1, 3, 5, 7, 10, 14, 21 and 30 days. SEM, EDX and XRF were conducted for microstructure characterization. RESULTS XTR and Solo did not show degradation when modified with PAA-CuI regardless of the concentration. The UTS for adhesives containing PAA-CuI remained unaltered relative to the controls. The percent viable cells were reduced for Solo 0.5mg/ml and XP 0.1 or 0.5mg/ml PAA-CuI. XP demonstrated the highest ion release. For all groups, the highest release was observed at days 1 and 14. SIGNIFICANCE PAA-CuI particles prevented the bond degradation of XTR and Solo after 1year without an effect on the UTS for any adhesive. Cell viability was affected for some adhesives. A similar pattern of copper release was demonstrated for all adhesives.
Collapse
Affiliation(s)
- Adi ALGhanem
- King Fahad Medical City, Makkah Al Mukarramah Branch Rd., As Sulimaniyah, Riyadh 11525, Saudi Arabia.
| | - Gabriela Fernandes
- Yashwantrao Chavan Dental College, 166/1, Vadgaon Gupta, Opp. M.I.D.C, Ahmednagar, Maharashtra 414003, India.
| | - Michelle Visser
- Department of Oral Biology, School of Dental Medicine, University at Buffalo, 3435 Main Street, Buffalo, NY 14214, USA.
| | - Rosemary Dziak
- Department of Oral Biology, School of Dental Medicine, University at Buffalo, 3435 Main Street, Buffalo, NY 14214, USA.
| | - Walter G Renné
- Department of Oral Rehabilitation and Restorative Dentistry, College of Dental Medicine, Medical University of South Carolina, 173 Ashley Ave., Charleston, SC 29425, USA.
| | - Camila Sabatini
- Department of Restorative Dentistry, School of Dental Medicine, University at Buffalo, 3435 Main Street, Buffalo, NY 14214, USA.
| |
Collapse
|
8
|
Ayyıldız S. The place of direct metal laser sintering (DMLS) in dentistry and the importance of annealing. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2015; 52:343. [DOI: 10.1016/j.msec.2015.03.016] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
9
|
Wang Q, Liu P, Sun Y, Gong T, Zhu M, Sun X, Zhang Z, Duan Y. Preparation and properties of biocompatible PS-PEG/calcium phosphate nanospheres. Nanotoxicology 2014; 9:190-200. [PMID: 24787691 DOI: 10.3109/17435390.2014.911381] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
A facile room-temperature method was used to prepare phosphatidylserine (PS)-poly(ethylene glycol) (PEG)/calcium phosphate (CaP) nanospheres (PS-poly(ethylene glycol) methyl ether/CaP nanospheres). Transmission electron microscopy (TEM) results confirmed that the PS-PEG/CaP porous nanospheres were spherical with a diameter of 8-12 nm. X-ray and thermo-gravimetric analysis (TGA) results also confirmed that the PS-PEG micelle was packed in the CaP shell. PS-PEG/CaP nanospheres exhibited little effect on the hemolysis, coagulation characteristics of blood and inflammatory response, demonstrating a negligible cytotoxicity response in LO2 liver cells. Experiments performed in zebrafish demonstrated that the PS-PEG/CaP nanospheres had a long circulatory residence time and did not induce apoptosis in zebrafish. Taken together, these results suggest that the PS-PEG/CaP nanospheres have great potential to be used as a drug carrier.
Collapse
Affiliation(s)
- Qi Wang
- State Key Laboratory of Oncogenes and Related Genes, Shanghai Cancer Institute, Renji Hospital, School of Medicine, Shanghai Jiao Tong University , Shanghai , China and
| | | | | | | | | | | | | | | |
Collapse
|
10
|
Wang Q, Liu P, Liu P, Gong T, Li S, Duan Y, Zhang Z. Preparation, blood coagulation and cell compatibility evaluation of chitosan-graft-polylactide copolymers. Biomed Mater 2014; 9:015007. [DOI: 10.1088/1748-6041/9/1/015007] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
11
|
Surface characteristics and corrosion properties of selective laser melted Co-Cr dental alloy after porcelain firing. Dent Mater 2013; 30:263-70. [PMID: 24388219 DOI: 10.1016/j.dental.2013.11.013] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2012] [Revised: 08/04/2013] [Accepted: 11/27/2013] [Indexed: 11/21/2022]
Abstract
OBJECTIVE We examined the surface characteristics and corrosion properties of selective laser melted (SLM) cobalt-chromium (Co-Cr) dental alloys before and after porcelain-fused-to-metal (PFM) firing. METHODS Samples were manufactured utilizing SLM techniques and control specimens were fabricated using traditional casting methods. The microstructure and surface composition were examined using metallographic microscopy, X-ray diffraction (XRD), and X-ray photoelectron spectroscopy (XPS). Corrosion properties were evaluated using electrochemical impedance spectroscopy. Student's t-test was used to evaluate differences in numerical results of electrochemical corrosion tests between SLM and cast specimens before or after PFM firing. The results of electrochemical corrosion tests of the SLM and cast samples before and after firing were analyzed using one-way ANOVA. RESULTS Although PFM firing altered the microstructure of the SLM specimens, they still exhibited a compact and homogeneous structure, and XPS analysis indicated that there were no significant differences in the surface composition of the specimens after firing. In artificial saliva at pH 5, the Rp value of the SLM specimens was 6.21MΩcm(-2) before firing and 2.84MΩcm(-2) after firing, suggesting there was no significant difference in electrochemical corrosion properties (P>0.05). In artificial saliva at pH 2.5, the Rp value of the SLM group was 4.80MΩcm(-2) before firing and 2.88MΩcm(-2) after firing, again indicating no significant difference in electrochemical corrosion properties (P>0.05). At pH 2.5, there was a significant difference in corrosion behavior between the cast and SLM groups, with the Rp value of the cast group being 0.78MΩcm(-2) vs. 2.88MΩcm(-2) for the SLM group. SIGNIFICANCE The improved post-firing corrosion resistance of SLM specimens provides further support for their use in prosthodontic applications, as the oral environment may become temporarily acidic following meals.
Collapse
|
12
|
Ayyıldız S, Soylu EH, Ide S, Kılıç S, Sipahi C, Pişkin B, Gökçe HS. Annealing of Co-Cr dental alloy: effects on nanostructure and Rockwell hardness. J Adv Prosthodont 2013; 5:471-8. [PMID: 24353888 PMCID: PMC3865205 DOI: 10.4047/jap.2013.5.4.471] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2013] [Revised: 11/06/2013] [Accepted: 11/17/2013] [Indexed: 11/10/2022] Open
Abstract
PURPOSE The aim of the study was to evaluate the effect of annealing on the nanostructure and hardness of Co-Cr metal ceramic samples that were fabricated with a direct metal laser sintering (DMLS) technique. MATERIALS AND METHODS Five groups of Co-Cr dental alloy samples were manufactured in a rectangular form measuring 4 × 2 × 2 mm. Samples fabricated by a conventional casting technique (Group I) and prefabricated milling blanks (Group II) were examined as conventional technique groups. The DMLS samples were randomly divided into three groups as not annealed (Group III), annealed in argon atmosphere (Group IV), or annealed in oxygen atmosphere (Group V). The nanostructure was examined with the small-angle X-ray scattering method. The Rockwell hardness test was used to measure the hardness changes in each group, and the means and standard deviations were statistically analyzed by one-way ANOVA for comparison of continuous variables and Tukey's HSD test was used for post hoc analysis. P values of <.05 were accepted as statistically significant. RESULTS The general nanostructures of the samples were composed of small spherical entities stacked atop one another in dendritic form. All groups also displayed different hardness values depending on the manufacturing technique. The annealing procedure and environment directly affected both the nanostructure and hardness of the Co-Cr alloy. Group III exhibited a non-homogeneous structure and increased hardness (48.16 ± 3.02 HRC) because the annealing process was incomplete and the inner stress was not relieved. Annealing in argon atmosphere of Group IV not only relieved the inner stresses but also decreased the hardness (27.40 ± 3.98 HRC). The results of fitting function presented that Group IV was the most homogeneous product as the minimum bilayer thickness was measured (7.11 Å). CONCLUSION After the manufacturing with DMLS technique, annealing in argon atmosphere is an essential process for Co-Cr metal ceramic substructures. The dentists should be familiar with the materials that are used in clinic for prosthodontics treatments.
Collapse
Affiliation(s)
- Simel Ayyıldız
- Department of Prosthodontics, Dental Health Sciences Center, Gulhane Military Medical Academy, Ankara, Turkey
| | - Elif Hilal Soylu
- Department of Physics, Karadeniz Technical University, Faculty of Science and Literature, Trabzon, Turkey
| | - Semra Ide
- Department of Physics Engineering, Faculty of Engineering, Hacettepe University, Ankara, Turkey
| | - Selim Kılıç
- Department of Public Health, Gulhane Military Medical Academy, Ankara, Turkey
| | - Cumhur Sipahi
- Department of Prosthodontics, Dental Health Sciences Center, Gulhane Military Medical Academy, Ankara, Turkey
| | - Bulent Pişkin
- Department of Prosthodontics, Dental Health Sciences Center, Gulhane Military Medical Academy, Ankara, Turkey
| | - Hasan Suat Gökçe
- Dental Health Service, Beytepe Military Hospital, Ankara, Turkey
| |
Collapse
|
13
|
McGinley EL, Moran GP, Fleming GJ. Biocompatibility effects of indirect exposure of base-metal dental casting alloys to a human-derived three-dimensional oral mucosal model. J Dent 2013; 41:1091-100. [DOI: 10.1016/j.jdent.2013.08.010] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2013] [Revised: 08/06/2013] [Accepted: 08/07/2013] [Indexed: 11/27/2022] Open
|
14
|
Abstract
The use of nickel casting alloys for long-term restorations in dentistry has long been controversial. A 'tug-of-war' between economic, engineering and biological considerations is central to this controversy; nickel-casting alloys have low costs and favorable physical properties, but are corrosion-prone in the oral environment. Clinicians and researchers have questioned the safety of nickel-containing dental alloys because several nickel compounds are known to cause adverse biological effects in vivo and in vitro in contexts outside of dentistry. The debate revolves around the extent to which corrosion products from oral restorations cause intraoral or systemic biological problems. Current evidence suggests that nickel alloys may be used successfully and safely in dentistry if clinical risks are taken into account. However, these alloys may cause significant clinical problems, primarily allergenic and inflammatory, if the risks are ignored.
Collapse
Affiliation(s)
- John C Wataha
- Department of Restorative Dentistry, University of Washington School of Dentistry, Seattle, WA 98195-7456, USA.
| | | | | |
Collapse
|
15
|
Abstract
We have highlighted that exposure of base-metal dental casting alloys to the acidogenic bacterium Streptococcus mutans significantly increases cellular toxicity following exposure to immortalized human TR146 oral keratinocytes. With Inductively Coupled Plasma-Mass Spectrometry (ICP-MS), S. mutans-treated nickel-based (Ni-based) and cobalt-chromium-based (Co-Cr-based) dental casting alloys were shown to leach elevated levels of metal ions compared with untreated dental casting alloys. We targeted several biological parameters: cell morphology, viable cell counts, cell metabolic activity, cell toxicity, and inflammatory cytokine expression. S. mutans-treated dental casting alloys disrupted cell morphology, elicited significantly decreased viable cell counts (p < 0.0001) and cell metabolic activity (p < 0.0001), and significantly increased cell toxicity (p < 0.0001) and inflammatory cytokine expression (p < 0.0001). S. mutans-treated Ni-based dental casting alloys induced elevated levels of cellular toxicity compared with S. mutans-treated Co-Cr-based dental casting alloys. While our findings indicated that the exacerbated release of metal ions from S. mutans-treated base-metal dental casting alloys was the likely result of the pH reduction during S. mutans growth, the exact nature of mechanisms leading to accelerated dissolution of alloy-discs is not yet fully understood. Given the predominance of S. mutans oral carriage and the exacerbated cytotoxicity observed in TR146 cells following exposure to S. mutans-treated base-metal dental casting alloys, the implications for the long-term stability of base-metal dental restorations in the oral cavity are a cause for concern.
Collapse
|
16
|
McGinley E, Moran G, Fleming G. Base-metal dental casting alloy biocompatibility assessment using a human-derived three-dimensional oral mucosal model. Acta Biomater 2012; 8:432-8. [PMID: 21889621 DOI: 10.1016/j.actbio.2011.08.017] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2011] [Revised: 08/15/2011] [Accepted: 08/17/2011] [Indexed: 02/02/2023]
Abstract
Nickel-chromium (Ni-Cr) alloys used in fixed prosthodontics have been associated with type IV Ni-induced hypersensitivity. We hypothesised that the full-thickness human-derived oral mucosa model employed for biocompatibility testing of base-metal dental alloys would provide insights into the mechanisms of Ni-induced toxicity. Primary oral keratinocytes and gingival fibroblasts were seeded onto Alloderm™ and maintained until full thickness was achieved prior to Ni-Cr and cobalt-chromium (Co-Cr) alloy disc exposure (2-72 h). Biocompatibility assessment involved histological analyses with cell viability measurements, oxidative stress responses, inflammatory cytokine expression and cellular toxicity analyses. Inductively coupled plasma mass spectrometry analysis determined elemental ion release levels. We detected adverse morphology with significant reductions in cell viability, significant increases in oxidative stress, inflammatory cytokine expression and cellular toxicity for the Ni-Cr alloy-treated oral mucosal models compared with untreated oral mucosal models, and adverse effects were increased for the Ni-Cr alloy that leached the most Ni. Co-Cr demonstrated significantly enhanced biocompatibility compared with Ni-Cr alloy-treated oral mucosal models. The human-derived full-thickness oral mucosal model discriminated between dental alloys and provided insights into the mechanisms of Ni-induced toxicity, highlighting potential clinical relevance.
Collapse
|
17
|
Development of a discriminatory biocompatibility testing model for non-precious dental casting alloys. Dent Mater 2011; 27:1295-306. [PMID: 21996445 DOI: 10.1016/j.dental.2011.09.013] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2011] [Revised: 08/31/2011] [Accepted: 09/21/2011] [Indexed: 11/24/2022]
Abstract
OBJECTIVES To develop an enhanced, reproducible and discriminatory biocompatibility testing model for non-precious dental casting alloys, prepared to a clinically relevant surface finishing condition, using TR146 oral keratinocyte cells. METHODS Comparative biocompatibility was determined following direct and indirect exposure of TR146 cells to two nickel-chromium (Ni-Cr) and a cobalt-chromium (Co-Cr) alloy-discs. The surface roughness of the discs was determined using a contact stylus profilometer and the elemental ion release by inductively coupled plasma mass spectrometry (ICP-MS). Subsequent biocompatibility analysis included cell morphology, cell density measurements with Trypan blue exclusion assay, inflammatory cytokine expression with ELISAs, cellular metabolic activity using XTT and cellular toxicity using lactate dehydrogenase (LDH) release assay. RESULTS TR146 cell morphology was altered following direct and indirect exposure to the Ni-Cr alloys but not the Co-Cr alloy. Significant reductions (all P<0.001) in viable cell density measurements, cellular metabolic activity, significant increases inflammatory cytokine expression and cellular toxicity were observed when TR146 cells were exposed to the Ni-Cr alloys. Significant decreases in cell density measurements, cellular metabolic activity, significant increases inflammatory cytokine expression and cellular toxicity for the Ni-Cr d.Sign(®)15 alloy compared with d.Sign(®)10 alloy were identifiable (all P<0.001). Cellular toxicity was attributed to nickel ion release levels in solution detected by ICP-MS analysis. DISCUSSION Nickel ions from the Ni-Cr alloys permeated the epithelial cells and activated a proinflammatory response, namely IL-1a, IL-8 and PGE2 expression. Further evidence of nickel ioninduced cell death was supported by the decreased biocompatibility of the highest nickel ion releasing alloy (d.Sign(®)15 compared with d.Sign(®)10) and the increased biocompatibility of the Co-Cr (d.Sign(®)30) alloy where nickel ions were absent.
Collapse
|