1
|
Maletin A, Knežević MJ, Koprivica DĐ, Veljović T, Puškar T, Milekić B, Ristić I. Dental Resin-Based Luting Materials-Review. Polymers (Basel) 2023; 15:4156. [PMID: 37896400 PMCID: PMC10610675 DOI: 10.3390/polym15204156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Revised: 10/11/2023] [Accepted: 10/13/2023] [Indexed: 10/29/2023] Open
Abstract
As cementation represents the last stage of the work involved in making various indirect restorations (metal ceramic crowns and bridges, full ceramic crowns and bridges, inlays, onlays, and fiber posts), its quality significantly contributes to the clinical success of the therapy performed. In the last two decades, the demand for ceramic indirect restorations in everyday dental practice has considerably increased primarily due to the growing significance of esthetics among patients, but also as a result of hypersensitivity reactions to dental alloys in some individuals. In this context, it is essential to ensure a permanent and reliable adhesive bond between the indirect restoration and the tooth structure, as this is the key to the success of aesthetic restorations. Resin-based luting materials benefit from excellent optical (aesthetic) and mechanical properties, as well as from providing a strong and durable adhesive bond between the restoration and the tooth. For this reason, resin cements are a reliable choice of material for cementing polycrystalline ceramic restorations. The current dental material market offers a wide range of resin cement with diverse and continually advancing properties. In response, we wish to note that the interest in the properties of resin-based cements among clinicians has existed for many years. Yet, despite extensive research on the subject and the resulting continued improvements in the quality of these materials, there is still no ideal resin-based cement on the market. The manuscript authors were guided by this fact when writing the article content, as the aim was to provide a concise overview of the composition, properties, and current trends, as well as some future guidelines for research in this field that would be beneficial for dental practitioners as well as the scientific community. It is extremely important to provide reliable and succinct information and guidelines for resin luting materials for dental dental practitioners.
Collapse
Affiliation(s)
- Aleksandra Maletin
- Faculty of Medicine, University of Novi Sad, 21000 Novi Sad, Serbia; (M.J.K.); (D.Đ.K.); (T.V.); (T.P.); (B.M.)
| | - Milica Jeremić Knežević
- Faculty of Medicine, University of Novi Sad, 21000 Novi Sad, Serbia; (M.J.K.); (D.Đ.K.); (T.V.); (T.P.); (B.M.)
| | - Daniela Đurović Koprivica
- Faculty of Medicine, University of Novi Sad, 21000 Novi Sad, Serbia; (M.J.K.); (D.Đ.K.); (T.V.); (T.P.); (B.M.)
| | - Tanja Veljović
- Faculty of Medicine, University of Novi Sad, 21000 Novi Sad, Serbia; (M.J.K.); (D.Đ.K.); (T.V.); (T.P.); (B.M.)
| | - Tatjana Puškar
- Faculty of Medicine, University of Novi Sad, 21000 Novi Sad, Serbia; (M.J.K.); (D.Đ.K.); (T.V.); (T.P.); (B.M.)
| | - Bojana Milekić
- Faculty of Medicine, University of Novi Sad, 21000 Novi Sad, Serbia; (M.J.K.); (D.Đ.K.); (T.V.); (T.P.); (B.M.)
| | - Ivan Ristić
- Faculty of Technology, University of Novi Sad, 21000 Novi Sad, Serbia;
| |
Collapse
|
2
|
Topbaş C, Çınar Ş, Altan B, Şirin DA, Fildişi MA. The effects of different root canal irrigation protocols and artificial aging procedures on the bond strength between dentin and hybrid ceramic posts. BMC Oral Health 2022; 22:590. [PMID: 36494809 PMCID: PMC9733272 DOI: 10.1186/s12903-022-02571-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Accepted: 11/08/2022] [Indexed: 12/13/2022] Open
Abstract
The purpose of this study is to investigate the effects of different root canal irrigation protocols applied to the dentin and artificial aging procedures on the micro pushout bond strength (mPBS) between dentin and hybrid ceramic posts. Seventy-five single-rooted mandibular premolar teeth were divided into 5 groups (Gr1-5). 50 of the teeth were used for the mPBS tests (n = 10), whereas 25 were used for the smear layer examinations (n = 5). Post space were prepared and irrigated with different irrigation-protocols in each group. (Gr1:[SS], Gr2:[NaOCl] + SS, Gr3:[EDTA] + NaOCl + SS, Gr4:[MA] + NaOCl + SS, Gr5:[Ch] + NaOCl + SS). Post and core pattern were fabricated with pattern resin and a fiber post, after scanning, the posts were milled with Vita Enamic resin ceramic block, and cemented. After 7 days the roots were sliced at thicknesses of 1 mm; half of them were subjected to mPBS test, while the other half were tested after undergoing mechanical cycling for artificial aging. For data analysis, the Shapiro-Wilk test was utilized to test normal distributions, 3-way analysis of variance was used to compare mPBS, and Tukey's HSD test was conducted for multiple comparisons. SEM analysis was performed for examination of failure modes and smear layer removal. Different root canal irrigation protocols affected mPBS significantly. While Gr4 had the highest mPBS, Gr1 had the lowest. Regarding to different zones, the highest mPBS was in coronal zone, and the lowest one was in the apical zone. The aging procedure also led to a statistically-significant decrease in mPBS. Most frequent failure modes were cohesive failure in dentin and mixed failure. Irrigation with 7%MA (Gr4) showed better performance than 17% EDTA (Gr3) in smear layer removal, especially at the apical zone of the tooth. This is critical for the success of root canal treatment and increased the mPBS to a higher extent in all zones of the tooth.
Collapse
Affiliation(s)
- Celalettin Topbaş
- grid.488643.50000 0004 5894 3909Department of Endodontics, Faculty of Dentistry, University of Health Sciences, +905055993249 Uskudar, Istanbul, Turkey
| | - Şevki Çınar
- grid.488643.50000 0004 5894 3909Department of Prosthodontics, Faculty of Dentistry, University of Health Sciences, Istanbul, Turkey
| | - Bike Altan
- grid.488643.50000 0004 5894 3909Department of Prosthodontics, Faculty of Dentistry, University of Health Sciences, Istanbul, Turkey
| | - Dursun Ali Şirin
- grid.488643.50000 0004 5894 3909Department of Endodontics, Faculty of Dentistry, University of Health Sciences, Istanbul, Turkey
| | - Mehmet Ali Fildişi
- grid.411781.a0000 0004 0471 9346Department of Restorative Dentistry, Faculty of Dentistry, Medipol University, Istanbul, Turkey
| |
Collapse
|
3
|
Influence of Dimethacrylate Monomer on the Polymerization Efficacy of Resin-Based Dental Cements-FTIR Analysis. Polymers (Basel) 2022; 14:polym14020247. [PMID: 35054654 PMCID: PMC8781089 DOI: 10.3390/polym14020247] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Revised: 09/12/2021] [Accepted: 09/14/2021] [Indexed: 01/27/2023] Open
Abstract
The degree of polymerization for dimethacrylate resin-based materials (BisGMA, TEGDMA, UDMA, HEMA) ranges from 55 to 75%. Literature data indicate that polymerization efficacy depends, among other factors, on the type of methacrylate resin comprising the material. The aim of this study was to evaluate the polymerization efficacy of four dental cement materials characterized by different polymerization mechanisms using FTIR analysis. In the present study, the FTIR method was adopted to analyze the degree of polymerization efficacy of four resin-based dental cement materials, two of which were self-cured and two were dual-cured cements. The IR spectral analysis was performed 24 h after the polymerization of the cementitious material. RelyX ARC cement exhibits the lowest polymerization efficacy (61.3%), while that of Variolink II (85.8%) and Maxcem Elite is the highest (90.1%). Although the efficacy of self-cured cements appears to be superior, the difference is not statistically significant (p = 0.280). Polymerization efficacy largely depends on the chemical structure of the material in terms of the presence of a particular methacrylate resin and less on the polymerization mechanism itself, i.e., whether it is a self-cured or dually cured dental cement. Thus, in clinical practice, cementitious materials with a higher proportion of TEGDMA compared with BisGMA are recommended.
Collapse
|
4
|
Vaddamanu SK, Vyas R, Bavabeedu SS, Arora S, Badiyani BK, Kumar A. In vitro Results of Scanning Technique on Assessing Cement Thickness and Interfacial Nanoleakage of Luted CAD/CAM-Fabricated Fiber Posts. JOURNAL OF PHARMACY AND BIOALLIED SCIENCES 2021; 13:S676-S678. [PMID: 34447179 PMCID: PMC8375806 DOI: 10.4103/jpbs.jpbs_761_20] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2020] [Revised: 11/24/2020] [Accepted: 11/30/2020] [Indexed: 11/29/2022] Open
Abstract
Background: Fiber posts are broadly used due to their good esthetics and elasticity close to that of dentin, which allows for uniform stress distribution within a root and lowers the possibility of nonrestorable root fractures. Aim and Objectives: The study assessed the layer of cement thickness and interfacial nanoleakage of luted fiber posts which were fabricated with CAD/CAM technology following direct scanning of the post space (DS) method, scanning of a polyether impression of the post space (IS), and scanning of a plaster model of the post space (MS). Methodology: Ninety premolars were chosen randomly and were assigned to three groups according to the scanning technique. Posts were computer designed and milled from experimental fiber-reinforced composite blocks. Results: The mean and standard deviation values of cement thickness, respectively, were: DS 172 ± 39 = m; IS 199 ± 55 = m, and MS MPa 272 ± 81 = m. The fiber posts fabricated following DS technique demonstrated superior performance compared to posts fabricated upon IS and MS, in terms of the post retention. The cement thickness did not differ between DS and IS, whereas in MS group, the cement layer was significantly thicker than in the remaining two groups. The scanning technique did not influence the sealing ability, as all groups showed comparable nanoleakage. Conclusion: Fiber posts fabricated following DS technique demonstrated superior performance. Furthermore, scanning technique did not influence the sealing ability, as all groups showed comparable nanoleakage.
Collapse
Affiliation(s)
- Sunil Kumar Vaddamanu
- Department of Dental Technology, College of Applied Medical Sciences, King Khalid University, Abha, Saudi Arabia
| | - Rajesh Vyas
- Department of Dental Technology, College of Applied Medical Sciences, King Khalid University, Abha, Saudi Arabia
| | - Shashit Shetty Bavabeedu
- Department of Restorative Dental Sciences, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Suraj Arora
- Department of Restorative Dental Sciences, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Bhumika Kamal Badiyani
- Reader, Department of Public Health Dentistry, Clinical Practitioner, Mumbai, Maharashtra, India
| | - Amit Kumar
- Reader, Department of Public Health Dentistry, Clinical Practitioner, Mumbai, Maharashtra, India
| |
Collapse
|
5
|
Khoroushi M, Najafabadi MA, Feiz A. Effects of Calcium Hypochlorite and Sodium Hypochlorite, as Root Canal Irrigants, on the Bond Strength of Glass Fiber Posts Cemented with Self-Adhesive Resin Cement. Front Dent 2019; 16:214-223. [PMID: 31858087 PMCID: PMC6911663 DOI: 10.18502/fid.v16i3.1593] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2018] [Accepted: 12/06/2018] [Indexed: 11/28/2022] Open
Abstract
Objectives: Calcium hypochlorite (Ca(OCl)2) is currently used as a root canal irrigant. The aim of this study was to compare the effects of calcium hypochlorite and sodium hypochlorite (NaOCl), as root canal irrigants, on the bond strength of posts cemented with a self-adhesive resin cement. Materials and Methods: In this in-vitro study, 40 maxillary central incisors with similar root lengths were decoronated. The teeth were randomly divided into five groups based on the irrigant used: Group 1: normal saline (control), Group 2: 2.5% sodium hypochlorite, Group 3: 5.25% sodium hypochlorite, Group 4: 2.5% calcium hypochlorite, and Group 5: 5% calcium hypochlorite. Root canal treatments were performed with Gates-Glidden drills and the irrigant corresponding to each group was used upon changing the file and for irrigating the post space. Then, glass fiber posts were cemented by BisCem self-adhesive cement. After applying 1,000 thermocycles at 5–55°C, three samples of the mid-section of each root were prepared: one for scanning electron microscopy (SEM), and the rest for push-out testing. Data were analyzed with SPSS 23 software using one-way analysis of variance and post-hoc Tukey’s test. Results: The highest and lowest mean bond strengths were recorded in groups 5 and 1, respectively. There was a significant difference between the 5% calcium hypochlorite group and the other groups (P<0.001). The difference between the other groups was not significant. Conclusion: The use of 5% calcium hypochlorite with self-adhesive cements increases the push-out bond strength of fiber posts to radicular dentin.
Collapse
Affiliation(s)
- Maryam Khoroushi
- Dental Materials Research Center, Department of Operative Dentistry, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
| | | | - Atiyeh Feiz
- Dental Materials Research Center, Department of Operative Dentistry, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
| |
Collapse
|
6
|
Eid RY, Koken S, Baba NZ, Ounsi H, Ferrari M, Salameh Z. Effect of Fabrication Technique and Thermal Cycling on the Bond Strength of CAD/CAM Milled Custom Fit Anatomical Post and Cores: An In Vitro Study. J Prosthodont 2019; 28:898-905. [PMID: 31397947 DOI: 10.1111/jopr.13101] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/30/2019] [Indexed: 11/27/2022] Open
Abstract
PURPOSE This study is to investigate the effect of milling custom fit anatomical post and cores from fiber reinforced composite and high-density polymer blocks using CAD/CAM technology on the bond strength to root canal dentin compared with prefabricated fiber posts, and to evaluate the influence of thermal cycling on the push out bond strength of the tested materials. MATERIALS AND METHODS Eighty extracted single-rooted premolars, endodontically treated and prepared to receive the posts, were randomly divided into four groups (n = 20): BLC: Custom-milled fiber-reinforced composite posts and cores (Trilor, Bioloren), AMC: Custom-milled high-density polymer posts and cores (Ambarino, Creamed), BLP: Prefabricated fiber-reinforced composite posts and composite core buildups (Bioloren; Filtek Bulk Fill Posterior, 3M). The posts used have the same matrix and fiber composition as BLC, RXP: Prefabricated posts and composite core buildups (RelyX fiber post, 3M; Filtek Bulk Fill Posterior); used as a control group. All of the posts were cemented using a self-adhesive resin cement (RelyX U200, 3M). Half of the sample was randomly assigned to thermal cycling in distilled water for 6,000 cycles to simulate aging, while the other half was tested for bond strength without thermal cycling. A push-out test was conducted using a universal testing machine until failure. Bond strength values were calculated in megapascals (MPa). The mode of failure was observed using a stereo microscope. Results were analyzed by two-way ANOVA followed by a Bonferroni post hoc test for comparison. The level of significance was set at p < 0.05. RESULTS Push-out bond strength was significantly higher (p <0.001) in the CAD/CAM post groups than in the groups with prefabricated posts regardless of the post material, while aging of the teeth did not significantly affect the push-out strength (p = 0.536). Failures were adhesive between cement and dentin for all groups except for AMC, where adhesive failure between the cement and the post was also observed. CONCLUSION The CAD/CAM manufacturing technique was proved to ameliorate the retention of the post and cores in the root canal. Thermal cycling did not affect the bond strength of the tested groups.
Collapse
Affiliation(s)
- Rita Y Eid
- Department of Prosthodontics, Faculty of Dental Medicine, Lebanese University, Beirut, Lebanon
| | - Serhat Koken
- Department of Prosthodontics and Dental Materials, Faculty of Dental Medicine, University of Siena, Siena, Italy
| | - Nadim Z Baba
- Advanced Education Program in Prosthodontics, Loma Linda University School of Dentistry, Loma Linda, California
| | - Hani Ounsi
- Department of Restorative Dentistry and Endodontics, Faculty of Dental Medicine Lebanese University, Beirut, Lebanon
| | - Marco Ferrari
- Department of Medical Biotechnologies, Division of Fixed Prosthodontics, University of Siena, Siena, Italy
| | - Ziad Salameh
- Department of Research, Faculty of Dental Medicine, Lebanese University, Beirut, Lebanon
| |
Collapse
|
7
|
Suzuki TYU, Pereira MA, Gomes-Filho JE, Wang L, Assunção WG, Santos PHD. Do Irrigation Solutions Influence the Bond Interface Between Glass Fiber Posts and Dentin? Braz Dent J 2019; 30:106-116. [DOI: 10.1590/0103-6440201901963] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2018] [Accepted: 06/12/2018] [Indexed: 11/22/2022] Open
Abstract
Abstract The aim of this study was to evaluate the push-out bond strength and interface permeability of glass-fiber posts in different regions of post space (cervical, middle, and apical) submitted to different irrigation solutions. Ninety single-rooted human teeth were submitted to endodontic treatment and divided into five groups, according to irrigation solutions: distilled water, 5.25% NaOCl, 25% polyacrylic acid, 2% chlorhexidine, and 23 ppm Ag NP dispersion. Each group was divided in 3 subgroups (n=6) according to cementation: SBU: Adper Scotchbond Universal + RelyX ARC; U200: RelyX U200; MCE: MaxCem Elite. Bond strength and sealing ability were measured in different areas of post space. The data was subjected to ANOVA and Fisher’s test (a=0,05). The silver nanoparticle solution showed highest bond strength values and lowest interface permeability in all thirds analyzed for SBU group. In the U200 group, the highest bond strength values were found for sodium hypochlorite solution, with significant difference between this solution and polyacrylic acid. A decrease in bond strength values in cervical to apical direction was found for MCE group and the same behavior were found for others groups. Regarding interface permeability, use of silver nanoparticle solution resulted in lower values in cervical and apical thirds. There was a decrease in bond strength in cervical to apical direction. Different irrigation solutions and intraradicular depth influenced the bond strength and interface permeability of adhesive material to dentin substrate. Silver nanoparticle solution can effectively be used as an irrigation agent in post space prior to fiber post cementation process.
Collapse
|
8
|
Tsintsadze N, Juloski J, Carrabba M, Goracci C, Vichi A, Grandini S, Ferrari M. Effects of scanning technique on in vitro performance of CAD/CAM-fabricated fiber posts. J Oral Sci 2018; 60:262-268. [PMID: 29925710 DOI: 10.2334/josnusd.17-0254] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Abstract
This study assessed push-out strength, cement layer thickness, and interfacial nanoleakage of luted fiber posts fabricated with computer-aided design/computer-assisted manufacture (CAD/CAM) technology after use of 1 of 3 scanning techniques, namely, direct scanning of the post space (DS), scanning of a polyether impression of the post space (IS), and scanning of a plaster model of the post space (MS). Thirty premolars were randomly assigned to three groups corresponding to the scanning technique. Posts were computer-designed and milled from experimental fiber-reinforced composite blocks. The mean (±SD) values for push-out strength and cement thickness were 17.1 ± 7.7 MPa and 162 ± 24 μm, respectively, for DS, 10.7 ± 4.6 MPa and 187 ± 50 μm for IS, and 12.0 ± 7.2 MPa and 258 ± 78 μm for MS specimens. Median (interquartile range) interfacial nanoleakage scores were 3 (2-4) for DS, 2.5 (2-4) for IS, and 3 (2-4) for MS. Post retention was better for fiber posts fabricated by DS technique than for those fabricated by IS and MS. Cement thickness did not differ between DS and IS specimens, but the cement layer was significantly thicker in the MS group than in the other two groups. Scanning technique did not affect sealing ability, as the three groups had comparable nanoleakage values.
Collapse
Affiliation(s)
| | - Jelena Juloski
- Department of Medical Biotechnologies, University of Siena.,Clinic for Paediatric and Preventive Dentistry, University of Belgrade
| | | | | | | | | | - Marco Ferrari
- Department of Medical Biotechnologies, University of Siena
| |
Collapse
|
9
|
Yamin PA, Pereira RD, Lopes FC, Queiroz AM, Oliveira HF, Saquy PC, Sousa-Neto MD. Longevity of bond strength of resin cements to root dentine after radiation therapy. Int Endod J 2018; 51:1301-1312. [PMID: 29729026 DOI: 10.1111/iej.12945] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2017] [Accepted: 04/26/2018] [Indexed: 12/13/2022]
Abstract
AIM To evaluate the bond strength and adhesive interface between several resin cements and root dentine immediately and 6 months after radiotherapy. METHODOLOGY Sixty maxillary canines were selected and randomly assigned to two groups (n = 30): one group was not irradiated and the other one was subjected to a cumulative radiation dose of 60 Gy. The teeth were sectioned to obtain roots 16 mm long and the canals were prepared with the Reciproc system (R50) and filled using a lateral condensation technique with an epoxy resin sealer. Each group was divided into three subgroups (n = 10) according to the resin cement used for fibreglass fibre post cementation: RelyX-U200, Panavia-F2.0 and RelyX ARC. The posts were cemented in accordance with the manufacturer's recommendations. Three 1-mm-thick dentine slices were then obtained from each root third. The first two slices in the crown-apex direction of each third were selected for the push-out test. The failure mode after debonding was determined with a stereo microscope. The third slice from each root third was selected for scanning electron microscopy (SEM) analyses to examine the resin cement-dentine interface with 100, 1000, 2000 and 4000× magnification. Bond strength data were analysed by anova and Tukey's test (α = 0.05). RESULTS Significantly lower bond strength (P < 0.0001) was obtained after irradiation compared to nonirradiated teeth. RelyX-U200 cemented fibre posts had the higher bond strength (15.17 ± 5.89) compared with RelyX ARC (P < 0.001) and Panavia-F2.0 (P < 0.001). The evaluation after 6 months revealed lower bond strength values compared to the immediate values (P < 0.001) for irradiated and nonirradiated teeth. Cohesive failures occurred in the irradiated dentine. SEM revealed fractures, microfractures and fewer collagen fibres in irradiated root dentine. RelyX-U200 and Panavia-F2.0 were associated with a juxtaposed interface of the cement with the radicular dentine in irradiated and nonirradiated teeth, and for RelyX ARC, hybrid layer formation and tags were observed in both irradiated and nonirradiated teeth. CONCLUSION Radiation was associated with a decrease in the push-out bond strength and with lower resin cement/root dentine interface adaptation. Self-adhesive resin cement was a better alternative for fibre post cementation in teeth subjected to radiation therapy. The bond strength decreased after 6 months.
Collapse
Affiliation(s)
- P A Yamin
- Department of Restorative Dentistry, University of São Paulo, Ribeirão Preto, Brazil
| | - R D Pereira
- Department of Restorative Dentistry, University of São Paulo, Ribeirão Preto, Brazil
| | - F C Lopes
- Department of Restorative Dentistry, University of São Paulo, Ribeirão Preto, Brazil
| | - A M Queiroz
- Department of Pediatric Dentistry, School of Dentistry of Ribeirão Preto, Ribeirão Preto, Brazil
| | - H F Oliveira
- Department of Internal Medicine, Faculty of Medicine of Ribeirão Preto, University of São Paulo, Ribeirão Preto, Brazil
| | - P C Saquy
- Department of Restorative Dentistry, University of São Paulo, Ribeirão Preto, Brazil
| | - M D Sousa-Neto
- Department of Restorative Dentistry, University of São Paulo, Ribeirão Preto, Brazil
| |
Collapse
|
10
|
Delai D, Tedesco M, de Almeida J, Chain MC, da Silveira Teixeira C, Santos Felippe MC, Felippe WT. Influence of Infected Root Dentin on the Bond Strength of a Self-adhesive Resin Cement. Contemp Clin Dent 2018; 9:26-30. [PMID: 29599579 PMCID: PMC5863404 DOI: 10.4103/ccd.ccd_683_17] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
AIM The aim of this study was to determine the bond strength (BS) of a self-adhesive resin cement to the contaminated root dentin. MATERIALS AND METHODS The crown and apical third of twenty single-rooted teeth were removed. The root canals were flared and 1-mm-thick root sections were obtained. The sections were rinsed, dried, and sterilized. The control group (n=20) was composed of one section of each third, which remained immersed in sterile trypticase soy broth (TSB) for 2 months. The other sections comprised the experimental group (n = 40) and were immersed in a suspension of Enterococcus faecalis. The culture medium was changed at every 4 days for 2 months. The sections were rinsed with distilled water, dried, and the root canal space was filled with the self-adhesive resin cement RelyX™ U200. After 24 h, the push-out test was performed and the types of interface failure were observed on a stereo microscope. STATISTICAL ANALYSIS Data were statistically analyzed by the nonparametric Mann-Whitney test (α=5%). RESULTS A significant reduction was observed in the BS of resin cement to the contaminated dentin compared to the healthy dentin, for both thirds analyzed (P < 0.05). The BS was significantly greater at the cervical third compared to the middle third for specimens in the experimental group (P < 0.05). Adhesive and mixed failures were observed more frequently in specimens contaminated with E. faecalis. CONCLUSION Bacterial contamination negatively infl uenced the BS of the self-adhesive resin cement to the root dentin, and there was a predominance of adhesive and mixed failures.
Collapse
Affiliation(s)
- Débora Delai
- Department of Conservative Dentistry, Federal University of Rio Grande do Sul (UFRGS), Porto Alegre, RS, Brazil
- Department of Dentistry, Federal University of Santa Catarina (UFSC), Florianópolis, SC, Brazil
| | - Maybell Tedesco
- Department of Dentistry, Federal University of Santa Catarina (UFSC), Florianópolis, SC, Brazil
| | - Josiane de Almeida
- Department of Dentistry, Federal University of Santa Catarina (UFSC), Florianópolis, SC, Brazil
- University of Southern Santa Catarina (Unisul), Palhoça, SC, Brazil
| | - Marcelo Carvalho Chain
- Department of Dentistry, Federal University of Santa Catarina (UFSC), Florianópolis, SC, Brazil
| | | | | | - Wilson Tadeu Felippe
- Department of Dentistry, Federal University of Santa Catarina (UFSC), Florianópolis, SC, Brazil
| |
Collapse
|
11
|
Effects of Epigallocatechin-3-gallate (EGCG) on the bond strength of fiber posts to Sodium hypochlorite (NaOCl) treated intraradicular dentin. Sci Rep 2017; 7:4235. [PMID: 28652570 PMCID: PMC5484673 DOI: 10.1038/s41598-017-04107-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2016] [Accepted: 05/10/2017] [Indexed: 11/09/2022] Open
Abstract
This study was to evaluate the effect of Epigallocatechin-3-gallate (EGCG) on the bond strength of two adhesive systems to the Sodium hypochlorite (NaOCl) treated intraradicular dentin. The roots were accepted regular root canal treatments and post space preparations, and further divided into eight groups according to the four post space pretreatments and two dentin adhesives [Single Bond 2 (SB2) and Clearfil SE Bond (CSB)] used. The push-out strength before and after thermocycling in different root region (coronal and apical), DC of the adhesive and morphologic patterns of treated post space were evaluated. NaOCl + EGCG groups showed the highest push-out strength regardless of the adhesive type, root region and time (P < 0.05). NaOCl pretreatment significantly decreased the push-out strengths and DC of CSB (P < 0.05). EGCG could improve the bonding properties of both SB2 and CSB to NaOCl treated intraradicular dentin. The effect of NaOCl on bonding of a fiber post depended on the type of the adhesive.
Collapse
|
12
|
Abd El-Ghany OS, Sherief AH. Zirconia based ceramics, some clinical and biological aspects: Review. ACTA ACUST UNITED AC 2016. [DOI: 10.1016/j.fdj.2016.10.002] [Citation(s) in RCA: 110] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
13
|
de Souza NC, Marcondes ML, da Silva DFF, Borges GA, Júnior LHB, Spohr AM. Relined Fiberglass Post: Effect of Luting Length, Resin Cement, and Cyclic Loading on the Bond to Weakened Root Dentin. Oper Dent 2016; 41:e174-e182. [DOI: 10.2341/15-233-l] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
This study evaluated the effects of luting length of the post, the resin cement, and cyclic loading on pull-out bond strength of fiberglass posts relined with composite resin in weakened roots. The canals of 80 bovine incisors were endodontically treated and weakened with diamond burs. The teeth were randomly divided into eight groups (n=10) according to the luting procedures of the relined fiberglass post (RFP): In groups 1, 2, 3, and 4, the RFPs were luted with RelyX ARC, and in groups 5, 6, 7, and 8 they were luted with RelyX U200. In groups 1, 3, 5, and 7, the RFPs were luted at a length of 5 mm, and in groups 2, 4, 6, and 8 they were luted at a length of 10 mm. Specimens from groups 3, 4, 7, and 8 were submitted to cyclic loading. Specimens were subjected to a pull-out bond strength test in a universal testing machine. The results (MPa) were analyzed by three-way analysis of variance and the Tukey post hoc test (α=0.05). Six human upper anterior teeth were used to analyze the bond interface by confocal laser scanning microscopy (CLSM). The pull-out bond strength of RFPs luted with RelyX U200 was statistically higher than that of RelyX ARC. Cyclic loading influenced the bond strength only for the luting length of 5 mm. CLSM analysis revealed the formation of resin cement tags for both materials. Luting length is an important factor in retaining RFPs in weakened roots when they are subjected to cyclic loading, and RelyX U200 resulted in greater bond strengths to the root canal in comparison with RelyX ARC.
Collapse
Affiliation(s)
- NC de Souza
- Niélli C. de Souza, MS, Restorative Dentistry, Pontifical Catholic University of Rio Grande do Sul, Rio Grande do Sul, Brazil
| | - ML Marcondes
- Maurem L. Marcondes, PhD, Restorative Dentistry, Pontifical Catholic University of Rio Grande do Sul Rio Grande do Sul, Brazil
| | - DFF da Silva
- Diego F.F. da Silva, MS, Restorative Dentristry, Pontifical Catholic University of Rio Grande do Sul, Rio Grande do Sul, Brazil
| | - GA Borges
- Gilberto Antonio Borges (Gilberto Antonio Borges), PhD, Dental Materials, University of Uberaba, Minas Gerais, Brazil
| | - LH Burnett Júnior
- Luiz Henrique Burnett Júnior, PhD, Restorative Dentistry, Pontifical Catholic University of Rio Grande do Sul, Rio Grande do Sul, Brazil
| | - AM Spohr
- Ana Maria Spohr, PhD, Dental Materials, Pontifical Catholic University of Rio Grande do Sul, Rio Grande do Sul, Brazil
| |
Collapse
|
14
|
Mushashe AM, Gonzaga CC, Cunha LFD, Furuse AY, Moro A, Correr GM. Effect of Enamel and Dentin Surface Treatment on the Self-Adhesive Resin Cement Bond Strength. Braz Dent J 2016; 27:537-542. [PMID: 27982230 DOI: 10.1590/0103-6440201600445] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2016] [Accepted: 06/30/2016] [Indexed: 11/21/2022] Open
Abstract
Abstract The aim of this study was to evaluate the effect of enamel and dentin surface treatment on the micro-shear bond strength of self-adhesive cement. Seventy-two extracted third molars had their crowns embedded in acrylic resin and worn to obtain a flat enamel or dentin surface. The enamel and dentin specimens were randomly assigned to 8 groups (n=12) that were based on surface treatment (11.5% polyacrylic acid solution or no treatment), substrate condition (wet or dry) and storage period (1 day or 90 days), and treated accordingly. Cylinders (1 × 1 mm) were fabricated using self-adhesive resin cement (RelyX U200) following the manufacturer's instructions. The specimens were stored in distilled water at 37 °C for either 1 day or 90 days and subjected to micro-shear bond strength test (EMIC DL 2000 at 0.5 mm/min). After this, the failure type of the specimens was determined. Data were subjected to statistical analysis (a=0.05). According to the results, the 11.5% polyacrylic acid application decreased the bond strength in both enamel and dentin samples. The moist groups showed higher bond strength than the dry ones, regardless of the substrate and surface treatment. Storage period did not influence bond strength. In conclusion, surface treatment with 11.5% polyacrylic acid and absence of moisture decreased the bond strength of the resin-cement (RelyU200), regardless of the storage period.
Collapse
|
15
|
Influence of root dentin treatment on the push-out bond strength of fiber posts. Odontology 2016; 105:170-177. [PMID: 27206914 DOI: 10.1007/s10266-016-0252-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2016] [Accepted: 04/30/2016] [Indexed: 10/21/2022]
Abstract
The aim of the present study was to assess whether different dentin conditioning protocols with different acids [phosphoric acid, ethylene diamine tetra acetic acid (EDTA), and polyacrylic acid (PAA)] influence the bond strength of fiber posts along the radicular depth when luted with self-adhesive resin cement. Twenty single-rooted teeth were randomly divided into four experimental groups (n = 5) according to dentin treatment: Group 1: no treatment; Group 2: etching with 35 % phosphoric acid for 10 s; Group 3: 17 % EDTA application for 60 s; and Group 4: conditioning with 25 % PAA for 30 s. RelyX Fiber Posts were luted with the self-adhesive resin cement RelyX Unicem 2 Automix (3M ESPE). Roots were transversally sectioned into nine 1-mm thick specimens, three corresponding to each root third and a push-out test was performed. Data were analyzed by two-way ANOVA and Tukey test (p < 0.05). Failure mode was determined and specimens with representative failures for each group were observed under scanning electron microscopy. According to the results, dentin treatment influenced the bond strength (p < 0.001), whereas the root third did not (p > 0.05). Fiber posts luted after treating dentin with phosphoric acid, and PAA exhibited the highest push-out bond strength values, while the lowest were obtained after EDTA application. Intermediate results were obtained when dentin was not conditioned. In conclusion, the bond strength of the self-adhesive resin cement RelyX Unicem 2 improves when root dentin is treated with 35 % phosphoric acid or 25 % PAA, before fiber posts luting irrespective of the root depth.
Collapse
|
16
|
Shafiei F, Yousefipour B, Mohammadi-Bassir M. Effect of Carbodiimide on Bonding Durability of Adhesive-cemented Fiber Posts in Root Canals. Oper Dent 2016; 41:432-40. [PMID: 26794191 DOI: 10.2341/15-099-l] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This study was undertaken to investigate whether using a protein cross-linker, 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC), improves bonding stability of fiber posts to root dentin using three resin cements. Sixty human maxillary central incisor roots were randomly divided into six groups after endodontic treatment, according to the cements used with and without EDC pretreatment. In the etch-and-rinse group, 0.3 M EDC aqueous solution was applied on acid-etched root dentin prior to Excite DSC/Variolink II for post cementation. In the self-etch and self-adhesive groups, EDC was used on EDTA-conditioned root space prior to application of ED Primer II/Panavia F2.0 and Clearfil SA, respectively. After microslicing the root dentin, a push-out bond strength (BS) test was performed immediately or after one-year of water storage for each group. Data were analyzed using three-way analysis of variance and Tukey tests (α=0.05). A significant effect of cement type, time, EDC, and Time × Cement and Time × EDC interactions were observed (p≤0.001). EDC pretreatment did not affect immediate bonding of the three cements (p>0.05). Aging significantly reduced the BS in all the groups (p≤0.001), but EDC groups exhibited a higher BS compared with the respective control groups (p<0.001). Despite the significant effect of aging on decreasing the BS of fiber post to radicular dentin, EDC could diminish this effect for the three tested cements.
Collapse
|
17
|
de Oliveira Moreira PE, Pamplona LS, Nascimento GCR, Esteves RA, Pessoa OF, Silva CM. Effects of Internal Bleaching on the Adhesion of Glass-Fiber Posts. Open Dent J 2015; 9:375-9. [PMID: 26962369 PMCID: PMC4763955 DOI: 10.2174/1874210601509010375] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2015] [Revised: 09/11/2015] [Accepted: 09/29/2015] [Indexed: 12/04/2022] Open
Abstract
Objective: We evaluated the effects of internal bleaching on the adhesion of glass-fiber posts (GFPs) luted with different resin cements. Methods: Forty extracted human single-root teeth were endodontically treated and divided into four groups (n=10): G1- conventional resin cement (CRC); G2- self-adhesive resin cement (SARC); G3- bleaching + CRC; and G4- bleaching + SARC. Specimens were sectioned transversally into three slices to perform the push-out test at the coronal, middle and apical regions of the root canals. Data were analyzed using analysis of variance and Tukey's test (p<0.05). Results: The push-out bond strength of GFPs luted with SARC after bleaching (G4) was significantly lower than that of the other groups (p<0.001). We found no statistically significant differences in push-out bond strength among the other groups. Significance: Internal bleaching reduced the adhesion of GFPs luted with SARC. The adhesion of GFPs luted with CRC was not decreased after bleaching.
Collapse
Affiliation(s)
| | - Lucianne S Pamplona
- Department of Dentistry, School of Dentistry of Federal University of Pará, Belém, Pará, Brazil
| | - Gláucia C R Nascimento
- Department of Dentistry, School of Dentistry of Federal University of Pará, Belém, Pará, Brazil
| | - Renata A Esteves
- Department of Prosthodontics, School of Dentistry of Federal University of Pará, Belém, Pará, Brazil
| | - Oscar F Pessoa
- Department of Endodontics, School of Dentistry of Federal University of Pará, Belém, Pará, Brazil
| | - Cecy M Silva
- Department of Dentistry, School of Dentistry of Federal University of Pará, Belém, Pará, Brazil
| |
Collapse
|
18
|
Li XJ, Zhao SJ, Niu LN, Tay FR, Jiao K, Gao Y, Chen JH. Effect of luting cement and thermomechanical loading on retention of glass fibre posts in root canals. J Dent 2013; 42:75-83. [PMID: 24200871 DOI: 10.1016/j.jdent.2013.10.017] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2013] [Revised: 10/07/2013] [Accepted: 10/29/2013] [Indexed: 11/25/2022] Open
Abstract
OBJECTIVES To evaluate the effect of luting cement and thermomechanical loading on the retention of glass fibre posts in root canals. METHODS One hundred and forty-four single-rooted human premolars were endodontically treated and restored with RelyX Fibre Posts. The teeth were divided into four groups according to the cements used (Fuji I, Fuji CEM, RelyX Unicem and RelyX ARC). Each group was further divided into two subgroups according to the method of ageing (immediately tested and after thermomechanical loading). Bond strength was evaluated using a pull-out test. Microleakage was examined quantitatively with dye penetration. The dentine-cement-post bonding interface was assessed using scanning electron microscopy. Data were analysed with two-way ANOVA (pull-out test) and Kruskal-Wallis analysis (microleakage). RESULTS The pull-out bond strength and microleakage were significantly affected by the type of cement and ageing. Although RelyX ARC showed the highest bond strength before thermomechanical loading (p<0.05), the sealing ability of this cement was worse than those exhibited in Fuji CEM and RelyX Unicem (p<0.05). After thermomechanical loading, pull-out strengths of Fuji I and Fuji CEM were significantly increased, whereas that of RelyX ARC group significantly decreased (p<0.05). The sealing ability of Fuji CEM was significantly better than the two resin cement groups (p<0.05) after ageing. CONCLUSION Fuji CEM demonstrates increased pull-out strength after thermomechanical loading and favourable sealing ability compared with the other cements. CLINICAL SIGNIFICANCE Resin-modified glass ionomer cements have the potential benefit of achieving long-term retention when used for luting glass fibre post to root canal dentine. So it may be recommended for the cementation of glass fibre post in clinics.
Collapse
Affiliation(s)
- Xiao-jing Li
- Department of Prosthodontics, School of Stomatology, Fourth Military Medical University, Changle Xi Road 145, Xi'an, 710032, China
| | - San-jun Zhao
- Department of Prosthodontics, School of Stomatology, Fourth Military Medical University, Changle Xi Road 145, Xi'an, 710032, China
| | - Li-na Niu
- Department of Prosthodontics, School of Stomatology, Fourth Military Medical University, Changle Xi Road 145, Xi'an, 710032, China
| | - Franklin R Tay
- Department of Endodontics, Georgia Regents University, Augusta, GA, USA
| | - Kai Jiao
- Department of Oral Anatomy and Physiology, School of Stomatology, Fourth Military Medical University, Changle Xi Road 145, Xi'an, 710032, China
| | - Yu Gao
- Department of Prosthodontics, School of Stomatology, Fourth Military Medical University, Changle Xi Road 145, Xi'an, 710032, China
| | - Ji-hua Chen
- Department of Prosthodontics, School of Stomatology, Fourth Military Medical University, Changle Xi Road 145, Xi'an, 710032, China.
| |
Collapse
|
19
|
Othman HI, Elshinawy MI, Abdelaziz KM. Retention of fiber posts to the optimally and over-prepared dowel spaces. J Adv Prosthodont 2013; 5:16-20. [PMID: 23508925 PMCID: PMC3597920 DOI: 10.4047/jap.2013.5.1.16] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2012] [Revised: 01/03/2013] [Accepted: 01/17/2013] [Indexed: 11/22/2022] Open
Abstract
PURPOSE To assess the retention of glass fiber post cemented with self-adhesive resin cement into optimum and over-prepared root canals following obturation in the presence of either eugenol (EB) or calcium hydroxide (CB)-based sealers. MATERIALS AND METHODS Roots of extracted premolars were endodontically-treated in 5 groups (n = 10). Roots of Group 1 (control) were left with no obturation and then optimally prepared to receive endodontic dowels. Other root canals were obturated with gutta-percha in the presence of either eugenol-based (Groups 2 and 4) or calcium hydroxide-based (Groups 3 and 5) sealer. Dowel spaces were prepared with optimal diameter in Groups 2 and 3, one size larger in Groups 4 and 5. Standardized fiber posts were luted to the prepared spaces using self-adhesive resin cement and itsretention was then tested on an universal testing machine. Both one-way ANOVA and Tukey's HSD comparisons (α=0.05) were used to identifythe significance of inter-group retention differences. Scanning electron microscopy (SEM) of both optimally and over-prepared dowel spaces was also considered to figure the nature of their interior out. RESULTS The post retention was significantly higher to the non-obturated, optimally-prepared dowel spaces of Group 1 compared to the obturated, optimally-prepared ones of Groups 2 and 3. For each dowel space diameter, root canals obturated using CB of Groups 3 and 5 showed significantly higher dowel retention compared to those obturated using EB of Groups 2 and 4. Post retention to the over-prepared dowel spaces of Groups 4 and 5 was significantly higher than that recorded for the optimally-prepared ones of Groups 1-3. SEM images revealed traces of endodontic sealer and gutta-percha on the walls of the optimally-prepared dowel spaces. CONCLUSION Despite the adverse effect of endodontic sealers on the retention of fiber posts, the over-preparation of dowel spaces helps to improve the retention.
Collapse
Affiliation(s)
- Hesham Ibrahim Othman
- Department of Prosthodontics, Faculty of Dentistry, Al-Azhar University, Cairo, Egypt. ; Department of Prosthodontics, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | | | | |
Collapse
|
20
|
Affiliation(s)
- Edward J Swift
- Department of Operative Dentistry, University of North Carolina School of Dentistry, Chapel Hill, NC, USA
| |
Collapse
|