1
|
Atalay Seçkiner P, Gönüldaş F, Akat B, Buyuksungur A, Orhan K. Investigation of Phase Transformation and Fracture Pattern as a Result of Long-Term Chewing Simulation and Static Loading of Reduced-Diameter Zirconia Implants. MATERIALS (BASEL, SWITZERLAND) 2024; 17:4719. [PMID: 39410290 PMCID: PMC11477572 DOI: 10.3390/ma17194719] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/29/2024] [Revised: 08/14/2024] [Accepted: 09/03/2024] [Indexed: 10/20/2024]
Abstract
While zirconia implants exhibit osseointegration comparable to that of titanium, concerns arise regarding low-temperature degradation and its potential impact on fracture strength. This study investigated the phase transformation and fracture characteristics of zirconia dental implants after aging through chewing simulation and subsequent static loading. The experimental setup involved 48 one-piece monobloc zirconia implants with diameters of 3.0 mm and 3.7 mm that had straight or angled abutments, with crown restorations, which were divided into six groups based on intraoral regions. The specimens underwent chewing simulation equal to five years of oral service, which was followed by static loading. Statistical analyses were performed for the data obtained from the tests. After dynamic and static loadings, the fractured samples were investigated by Raman spectroscopy to analyze the phase composition and micro-CT to evaluate fracture surfaces and volume changes. According to the results, narrow-diameter zirconia implants have low mechanical durability. The fracture levels, fracture patterns, total porosity, and implant fracture volume values varied according to the implant diameter and phase transformation grade. It was concluded that phase transformation initially guides the propagation of microcracks in zirconia implants, enhancing fracture toughness up to a specific threshold; however, beyond that point, it leads to destructive consequences.
Collapse
Affiliation(s)
- Pelin Atalay Seçkiner
- Department of Prosthodontics, Faculty of Dentistry, Niğde Ömer Halisdemir University, Niğde 51240, Turkey
| | - Fehmi Gönüldaş
- Department of Prosthodontics, Faculty of Dentistry, Ankara University, Ankara 06100, Turkey; (F.G.); (B.A.)
| | - Bora Akat
- Department of Prosthodontics, Faculty of Dentistry, Ankara University, Ankara 06100, Turkey; (F.G.); (B.A.)
| | - Arda Buyuksungur
- Department of Basic Medical Sciences, Ankara University, Ankara 06100, Turkey;
| | - Kaan Orhan
- Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara 06100, Turkey;
- Department of Oral Diagnostics, Faculty of Dentistry, Semmelweis University, 1088 Budapest, Hungary
| |
Collapse
|
2
|
Ciszyński M, Chwaliszewski B, Simka W, Dominiak M, Gedrange T, Hadzik J. Zirconia Dental Implant Designs and Surface Modifications: A Narrative Review. MATERIALS (BASEL, SWITZERLAND) 2024; 17:4202. [PMID: 39274592 PMCID: PMC11396535 DOI: 10.3390/ma17174202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2024] [Revised: 08/14/2024] [Accepted: 08/23/2024] [Indexed: 09/16/2024]
Abstract
Titanium currently has a well-established position as the gold standard for manufacturing dental implants; however, it is not free of flaws. Mentions of possible soft-tissue discoloration, corrosion, and possible allergic reactions have led to the development of zirconia dental implants. Various techniques for the surface modification of titanium have been applied to increase titanium implants' ability to osseointegrate. Similarly, to achieve the best possible results, zirconia dental implants have also had their surface modified to promote proper healing and satisfactory long-term results. Despite zirconium oxide being a ceramic material, not simply a metal, there have been mentions of it being susceptible to corrosion too. In this article, we aim to review the literature available on zirconia implants, the available techniques for the surface modification of zirconia, and the effects of these techniques on zirconia's biological properties. Zirconia's biocompatibility and ability to osseointegrate appears unquestionably good. Despite some of its mechanical properties being, factually, inferior to those of titanium, the benefits seem to outweigh the drawbacks. Zirconia implants show very good success rates in clinical research. This is partially due to available methods of surface treatment, including nanotopography alterations, which allow for improved wettability, bone-to-implant contact, and osteointegration in general.
Collapse
Affiliation(s)
- Michał Ciszyński
- Department of Dental Surgery, Faculty of Medicine and Dentistry, Medical University of Wroclaw, 50-425 Wroclaw, Poland
| | - Bartosz Chwaliszewski
- Department of Dental Surgery, Faculty of Medicine and Dentistry, Medical University of Wroclaw, 50-425 Wroclaw, Poland
| | - Wojciech Simka
- Faculty of Chemistry, Silesian University of Technology, 44-100 Gliwice, Poland
| | - Marzena Dominiak
- Department of Dental Surgery, Faculty of Medicine and Dentistry, Medical University of Wroclaw, 50-425 Wroclaw, Poland
| | - Tomasz Gedrange
- Department of Dental Surgery, Faculty of Medicine and Dentistry, Medical University of Wroclaw, 50-425 Wroclaw, Poland
- Department of Orthodontics, Technische Universität Dresden, 01069 Dresden, Germany
| | - Jakub Hadzik
- Department of Dental Surgery, Faculty of Medicine and Dentistry, Medical University of Wroclaw, 50-425 Wroclaw, Poland
| |
Collapse
|
3
|
Qin W, Shen MH, Gan N, Xing BH, Sun J, Zhao Z, Jiao T. Biological Properties of 3D-Printed Zirconia Implants with p-Cell Structures. J Dent Res 2024; 103:388-397. [PMID: 38374666 DOI: 10.1177/00220345231222819] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/21/2024] Open
Abstract
Research on 3-dimensional (3D) printed porous zirconia-based dental implants is still in its infancy. This study aimed to evaluate the biological responses of novel zirconia implants with p-cell structures fabricated by 3D printing. The solid zirconia samples exhibited comparable density, 3-point flexural strength, and accelerated aging properties compared to specimens prepared previously by conventional methods. Cell-based experiments showed that the p-cell structure promoted cell proliferation, adhesion, and osteogenesis-related protein expression. Mechanical tests showed that both p-cell and control implants could withstand a torque of 35 Ncm without breaking. The mean maximum breaking loads of p-cell and control implants were 1,222.429 ± 115.591 N and 1,903.857 ± 250.673 N, respectively, which were much higher than the human physiological chewing force and human mean maximum occlusal force. An animal experiment showed that the bone trabeculae around the implants were significantly thicker, more numerous, and denser in the p-cell group than in the control group. This work could provide promising guidance for further exploring 3D printing techniques for porous zirconia bionic implants in dentistry.
Collapse
Affiliation(s)
- W Qin
- Department of Prosthodontics, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology and Shanghai Research Institute of Stomatology, Shanghai, China
| | - M H Shen
- School of Material Science and Engineering, Shanghai Institute of Technology, Shanghai, China
- College of Materials Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing, China
| | - N Gan
- Department of Prosthodontics, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology and Shanghai Research Institute of Stomatology, Shanghai, China
| | - B H Xing
- School of Material Science and Engineering, Shanghai Institute of Technology, Shanghai, China
| | - J Sun
- Department of Prosthodontics, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology and Shanghai Research Institute of Stomatology, Shanghai, China
| | - Z Zhao
- School of Material Science and Engineering, Shanghai Institute of Technology, Shanghai, China
| | - T Jiao
- Department of Prosthodontics, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology and Shanghai Research Institute of Stomatology, Shanghai, China
| |
Collapse
|
4
|
Aliberti SM, Funk RHW, De Stefano M, Hoffmann T, Capunzo M. An epidemiological qualitative/quantitative SWOT-AHP analysis in order to highlight the positive or critical aspects of dental implants: A pilot study. Clin Exp Dent Res 2024; 10:e2836. [PMID: 38450945 PMCID: PMC10918715 DOI: 10.1002/cre2.836] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Revised: 12/15/2023] [Accepted: 12/22/2023] [Indexed: 03/08/2024] Open
Abstract
OBJECTIVES In recent years, dental implants are increasing in popularity due to their high success rate, demonstrated functionality, and aesthetic treatment results. Scientific research is very active in proposing improvements in the quality and survival of implants, taking into consideration various aspects. The objective of this study was to provide a holistic epidemiologic view of the state of dental implants, using a systematic approach based on a multimethod SWOT (Strengths, Weaknesses, Opportunities, and Threats) analysis and AHP (analytical hierarchical process) qualitative-quantitative analysis to identify the characteristics that can determine their success or failure. MATERIALS AND METHODS The study used the hybrid method of SWOT-AHP. RESULTS Analysis of the results showed that among strengths, the skill of the dentist was considered the most important factor, followed by the success of dental implants in the old people; among weaknesses, bruxism and chronic diseases were highlighted; for opportunities, biomechanical behavior, in terms of good mechanical strength and good tribological resistance to chemical and physical agents in the oral cavity, were considered the most important factors; finally, among threats, medical liability and biomechanical problems had equal weight. CONCLUSIONS This study applied a multimethod SWOT-AHP approach to bring out favorable or critical evidence on the topic of dental implants. In accordance with the result of the strategic vector identified in the Twisting zone Adjustment type section, showed that implant surgery is a widespread technique but always needs improvement to increase the likelihood of success and reduce the complications that can lead to implant failure.
Collapse
Affiliation(s)
- Silvana Mirella Aliberti
- Department of Medicine, Surgery and Dentistry, “Scuola Medica Salernitana”University of SalernoSalernoItaly
| | - Richard H. W. Funk
- Institute of AnatomyTechnische Universität (TU) DresdenDresdenGermany
- Division of Preventive MedicineDresden International University (DIU)DresdenGermany
| | - Marco De Stefano
- Department of Industrial EngineeringUniversity of SalernoSalernoItaly
| | - Thomas Hoffmann
- Division of Preventive MedicineDresden International University (DIU)DresdenGermany
| | - Mario Capunzo
- Department of Medicine, Surgery and Dentistry, “Scuola Medica Salernitana”University of SalernoSalernoItaly
| |
Collapse
|
5
|
Jiang C, Ding M, Zhang J, Zhu C, Qin W, Zhao Z, Jiao T. 3D Printed Porous Zirconia Biomaterials based on Triply Periodic Minimal Surfaces Promote Osseointegration In Vitro by Regulating Osteoimmunomodulation and Osteo/Angiogenesis. ACS APPLIED MATERIALS & INTERFACES 2024. [PMID: 38501200 DOI: 10.1021/acsami.3c18799] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/20/2024]
Abstract
The triply periodic minimal surface (TPMS) is a highly useful structure for bone tissue engineering owing to its nearly nonexistent average surface curvature, high surface area-to-volume ratio, and exceptional mechanical energy absorption properties. However, limited literature is available regarding bionic zirconia implants using the TPMS structure for bone regeneration. Herein, we employed the digital light processing (DLP) technology to fabricate four types of zirconia-based TPMS structures: P-cell, S14, IWP, and Gyroid. For cell proliferation, the four porous TPMS structures outperformed the solid zirconia group (P-cell > S14 > Gyroid > IWP > ZrO2). In vitro assessments on the biological responses and osteogenic properties of the distinct porous surfaces identified the IWP and Gyroid structures as promising candidates for future clinical applications of porous zirconia implants because of their superior osteogenic capabilities (IWP > Gyroid > S14 > P-cell > ZrO2) and mechanical properties (ZrO2 > IWP > Gyroid > S14 > P-cell). Furthermore, the physical properties of the IWP/Gyroid surface had more substantial effects on bone immune regulation by reducing macrophage M1 phenotype polarization while increasing M2 phenotype polarization compared with the solid zirconia surface. Additionally, the IWP and Gyroid groups exhibited enhanced immune osteogenesis and angiogenesis abilities. Collectively, these findings highlight the substantial impact of topology on bone/angiogenesis and immune regulation in promoting bone integration.
Collapse
Affiliation(s)
- Chunlan Jiang
- Department of Prosthodontics, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, P. R. China
- Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, Shanghai 200062, P. R. China
| | - Mengting Ding
- Department of Prosthodontics, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, P. R. China
- Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, Shanghai 200062, P. R. China
| | - Jin Zhang
- Department of Prosthodontics, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, P. R. China
- Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, Shanghai 200062, P. R. China
| | - Chenyuan Zhu
- Department of Prosthodontics, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, P. R. China
- Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, Shanghai 200062, P. R. China
| | - Wei Qin
- Department of Prosthodontics, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, P. R. China
- Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, Shanghai 200062, P. R. China
| | - Zhe Zhao
- Jiaxing CeramPlus Technology Co. Ltd., Jiashan 314100, Zhejiang, P. R. China
| | - Ting Jiao
- Department of Prosthodontics, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, P. R. China
- Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, Shanghai 200062, P. R. China
| |
Collapse
|
6
|
Mohseni P, Soufi A, Chrcanovic BR. Clinical outcomes of zirconia implants: a systematic review and meta-analysis. Clin Oral Investig 2023; 28:15. [PMID: 38135804 PMCID: PMC10746607 DOI: 10.1007/s00784-023-05401-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Accepted: 12/04/2023] [Indexed: 12/24/2023]
Abstract
PURPOSE To assess the clinical outcomes of zirconia dental implants based on an updated systematic literature review. METHODS An electronic search was performed in three databases, last updated in June 2023, supplemented by hand searching. The eligibility criteria were clinical studies reporting patients rehabilitated with zirconia implants. The cumulative survival rate (CSR) of implants was calculated. A meta-analysis for marginal bone loss (MBL) under different follow-up times and a meta-regression assessing the relationship between mean MBL and follow-up were done. RESULTS Twenty-five studies were included (4017 implants, 2083 patients). Seven studies had follow-up longer than 60 months. 172 implants failed, after a mean of 12.0 ± 16.1 months (min-max 0.3-86.0), of which 47 early failures, and 26 due to implant fracture, the majority in narrow-diameter implants. The 10-year CSR was 95.1%. Implants with coronal part prepared by drills presented statistically significant lower survival than non-prepared implants (p < 0.001). Two-piece implants presented lower survival than one-piece implants (p = 0.017). Implants discontinued from the market presented lower survival than the commercially available ones (p < 0.001). The difference in survival was not significant between implants in maxilla and mandible (p = 0.637). The mean MBL fluctuated between 0.632 and 2.060 mm over long periods of observation (up until 132 months). There was an estimated MBL increase of 0.005 mm per additional month of follow-up. CONCLUSION Zirconia implants present high 10-year CSR and short-term low MBL. The review was registered in PROSPERO (CRD42022342055). CLINICAL RELEVANCE The clinical outcomes observed for zirconia dental implants are very promising, although these have not yet been extensively studied as titanium alloy implants.
Collapse
Affiliation(s)
| | - Ahmad Soufi
- Faculty of Odontology, Malmö University, Malmö, Sweden
| | - Bruno Ramos Chrcanovic
- Department of Oral and Maxillofacial Surgery and Oral Medicine, Faculty of Odontology, Malmö University, Carl Gustafs Väg 34, 214 21, Malmö, Sweden.
| |
Collapse
|
7
|
A brief review on fatigue test of ceramic and some related matters in Dentistry. J Mech Behav Biomed Mater 2023; 138:105607. [PMID: 36549251 DOI: 10.1016/j.jmbbm.2022.105607] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Revised: 11/28/2022] [Accepted: 12/05/2022] [Indexed: 12/12/2022]
Abstract
The characteristics of dental ceramics have been extensively studied over the years to provide highly qualified materials for use in prosthetic restorations. The ability to adhere to dental substrates, outstanding aesthetics (translucency, color, and substrate masking ability) and improved mechanical properties provide these materials with optical features and high strength to withstand masticatory stimuli. Different classifications are adopted, and it is generally considered that glass-ceramics have better optical characteristics due to the high glass content, and polycrystalline ceramics have superior strength favored by their densified and organized crystals, hampering crack growth. This knowledge was largely built-up during years of scientific research through different testing methodologies, but mainly employing static loads. It is important to not only take into account the intensity of loads that these materials will be exposed to, but also the effect of the intermittence of cyclic load application leading to mechanical fatigue and the influence of factors related to the crack origin and their propagation under this condition. Furthermore, the bonding surface of ceramic restorations requires surface treatments that improve the bond strength to luting agents; however, these treatments require caution because of their potential to produce defects and affect the structural behavior. Moreover, ceramic restorations often require internal adjustments for proper seating or external adjustments for fitting the occlusal contact with the antagonist. In this sense, finishing/polishing protocols may alter the defect population, as luting agents may also interact by filling in the superficial defects on the restoration intaglio surface. Thus, the balance among all these factors will define the performance of a restorative setup, as well as the posterior exposure to the humid environment and the masticatory stimuli (cyclical loading), which may favor developing slow and subcritical growth of cracks in ceramic materials and the degradation of the bond interface. Therefore, it is essential that the concepts which explain the fatigue mechanism are understood, as well as the crack propagation and failure patterns of restorative ceramic materials.
Collapse
|
8
|
Li W, Ding Q, Sun F, Liu B, Yuan F, Zhang L, Bao R, Gu J, Lin Y. Fatigue behavior of zirconia with microgrooved surfaces produced using femtosecond laser. Lasers Med Sci 2023; 38:33. [PMID: 36598586 DOI: 10.1007/s10103-022-03679-w] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Accepted: 11/19/2022] [Indexed: 01/05/2023]
Abstract
Femtosecond laser is a promising surface treatment tool for zirconia implant. In this study, the fatigue behavior of zirconia specimens with microgrooved surfaces formed by femtosecond laser is reported. One hundred sixty CAD/CAM zirconia bars (20 mm × 4 mm × 1.4 mm) were evenly divided into four groups with different surface: as sintered; sandblasted with 110 μm Al2O3; femtosecond laser produced microgrooves having 50 μm width, 30 μm depth, and 100 μm pitch; microgrooves having 30 μm width, 20 μm depth, and 60 μm pitch. The femtosecond laser formed micro/nanostructured microgrooves with precise size on zirconia surfaces. XRD analysis indicated that microgrooved surface showed no obvious tetragonal-to-monoclinic phase transformation. The fatigue strength of sandblasted specimens (728 MPa) was significantly higher than that of as sintered specimens (570 MPa). However, the fatigue strength of specimens with microgrooved surface decreased to about 360-380 MPa. The results suggest femtosecond laser is an effective technique to regulate the surface microtopography of zirconia, while further investigations are needed to improve its fatigue behavior.
Collapse
Affiliation(s)
- Wenjin Li
- Department of Prosthodontics, Peking University School and Hospital of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, 100081, China
| | - Qian Ding
- Department of Prosthodontics, Peking University School and Hospital of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, 100081, China
| | - Fengbo Sun
- School of Materials Science and Engineering, Tsinghua University, 100084, Beijing, China
| | - Binchao Liu
- School of Aeronautic Science and Engineering, Beihang University, 100191, Beijing, China
| | - Fusong Yuan
- Center of Digital Dentistry, Peking University School and Hospital of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Research Center of Engineering and Technology for Digital Dentistry, Ministry of Health, Beijing, 100081, China
| | - Lei Zhang
- Department of Prosthodontics, Peking University School and Hospital of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, 100081, China.
| | - Rui Bao
- School of Aeronautic Science and Engineering, Beihang University, 100191, Beijing, China
| | - Jinghua Gu
- School of Materials Science and Engineering, Beihang University, Beijing, 100191, China
| | - Yuanhua Lin
- School of Materials Science and Engineering, Tsinghua University, 100084, Beijing, China
| |
Collapse
|
9
|
Zhang F, Monzavi M, Li M, Čokić S, Manesh A, Nowzari H, Vleugels J, Van Meerbeek B. Fracture analysis of one/two-piece clinically failed zirconia dental implants. Dent Mater 2022; 38:1633-1647. [PMID: 36064469 DOI: 10.1016/j.dental.2022.08.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Revised: 08/13/2022] [Accepted: 08/18/2022] [Indexed: 11/25/2022]
Abstract
OBJECTIVES Analyzing factors that may have led to fracture of zirconia implants by macro/micro-fractography. METHODS Six one-piece and ten two-piece full-ceramic zirconia implants from two manufacturers, Z-Systems and CeraRoot, were retrieved after clinical failure. The time-to-failure ranged from 3 to 49 months. Optical and scanning electron microscopy (SEM) were used to analyze the fracture planes at the macro- and microscopic level. Treatment planning, surgical protocol, fracture-origin location and characteristic fracture features were assessed. RESULTS The fracture of all implants seemed to have been primarily due to overload in bending mode, while the fracture-initiation sites varied for the one- and two-piece implants. The fracture of all one-piece implants originated in the constriction region between two threads in the endosseous implant part. For two-piece implants, the abutment neck, internal abutment-implant connections and inner threads were found to be the main fracture-initiation sites. Surface defects at the root area for one-piece implants and damages at the abutment surface for two-piece implants were connected to the fracture origins. Importantly, the clinical failures of implants were often found to result from combined effects related to patient aspects, treatment planning/protocols, a high bending moment at the weakest link, implant-surface conditions and specific implant designs. SIGNIFICANCE This study provided information to be considered for future optimization of treatment planning and the surgical protocol for zirconia implants. Optimization of the surface conditions and the zirconia-starting powder were also suggested.
Collapse
Affiliation(s)
- Fei Zhang
- KU Leuven, Department of Materials Engineering, Kasteelpark Arenberg 44, B-3001 Leuven, Belgium`; KU Leuven, Department of Oral Health Sciences, BIOMAT - Biomaterials Research Group & UZ Leuven (University Hospitals Leuven), Dentistry, Kapucijnenvoer 7 block a, B-3000 Leuven, Belgium.
| | - Mona Monzavi
- Periodontics and Ceramic Implantology (private Practice), 1401N Tustin Ave Suite #345, Santa Ana, CA 92705, USA
| | - Maoyin Li
- KU Leuven, Department of Materials Engineering, Kasteelpark Arenberg 44, B-3001 Leuven, Belgium`
| | - Stevan Čokić
- KU Leuven, Department of Oral Health Sciences, BIOMAT - Biomaterials Research Group & UZ Leuven (University Hospitals Leuven), Dentistry, Kapucijnenvoer 7 block a, B-3000 Leuven, Belgium
| | - Al Manesh
- Mission Dental Implant Center (private Practice), 26800 Crown Valley Pkwy Ste 425, Mission Viejo, CA 92691, USA
| | - Hessam Nowzari
- Periodontics and Implant Dentistry (private practice), 120 S Spalding Dr #201, Beverlyhills, CA 90210, USA
| | - Jef Vleugels
- KU Leuven, Department of Materials Engineering, Kasteelpark Arenberg 44, B-3001 Leuven, Belgium`
| | - Bart Van Meerbeek
- KU Leuven, Department of Oral Health Sciences, BIOMAT - Biomaterials Research Group & UZ Leuven (University Hospitals Leuven), Dentistry, Kapucijnenvoer 7 block a, B-3000 Leuven, Belgium
| |
Collapse
|
10
|
Zhang F, Spies BC, Willems E, Inokoshi M, Wesemann C, Cokic SM, Hache B, Kohal RJ, Altmann B, Vleugels J, Van Meerbeek B, Rabel K. 3D printed zirconia dental implants with integrated directional surface pores combine mechanical strength with favorable osteoblast response. Acta Biomater 2022; 150:427-441. [PMID: 35902036 DOI: 10.1016/j.actbio.2022.07.030] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2022] [Revised: 06/25/2022] [Accepted: 07/19/2022] [Indexed: 11/01/2022]
Abstract
Dental implants need to combine mechanical strength with promoted osseointegration. Currently used subtractive manufacturing techniques require a multi-step process to obtain a rough surface topography that stimulates osseointegration. Advantageously, additive manufacturing (AM) enables direct implant shaping with unique geometries and surface topographies. In this study, zirconia implants with integrated lamellar surface topography were additively manufactured by nano-particle ink-jetting. The ISO-14801 fracture load of as-sintered implants (516±39 N) resisted fatigue in 5-55°C water thermo-cycling (631±134 N). Remarkably, simultaneous mechanical fatigue and hydrothermal aging at 90°C significantly increased the implant strength to 909±280 N due to compressive stress generated at the seamless transition of the 30-40 µm thick, rough and porous surface layer to the dense implant core. This unique surface structure induced an elongated osteoblast morphology with uniform cell orientation and allowed for osteoblast proliferation, long-term attachment and matrix mineralization. In conclusion, the developed AM zirconia implants not only provided high long-term mechanical resistance thanks to the dense core along with compressive stress induced at the transition zone, but also generated a favorable osteoblast response owing to the integrated directional surface pores. STATEMENT OF SIGNIFICANCE: : Zirconia ceramics are becoming the material of choice for metal-free dental implants, however significant efforts are required to obtain a rough/porous surface for enhanced osseointegration, along with the risk of surface delamination and/or microstructure variation. In this study, we addressed the challenge by additively manufacturing implants that seamlessly combine dense core with a porous surface layer. For the first time, a unique surface with a directional lamellar pore morphology was additively obtained. This AM implant also provided strength as strong as conventionally manufactured zirconia implants before and after long-term fatigue. Favorable osteoblast response was proved by in-vitro cell investigation. This work demonstrated the opportunity to AM fabricate novel ceramic implants that can simultaneously meet the mechanical and biological functionality requirements.
Collapse
Affiliation(s)
- Fei Zhang
- KU Leuven (University of Leuven), Department of Materials Engineering, Leuven, Belgium; KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & UZ Leuven (University Hospitals Leuven), Dentistry, Leuven, Belgium.
| | - Benedikt C Spies
- University of Freiburg, Faculty of Medicine, Center for Dental Medicine, Department of Prosthetic Dentistry, Freiburg, Germany
| | - Evita Willems
- KU Leuven (University of Leuven), Department of Materials Engineering, Leuven, Belgium; KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & UZ Leuven (University Hospitals Leuven), Dentistry, Leuven, Belgium
| | - Masanao Inokoshi
- Tokyo Medical and Dental University, Graduate School of Medical and Dental Sciences, Department of Gerodontology and Oral Rehabilitation, Tokyo, Japan
| | - Christian Wesemann
- University of Freiburg, Faculty of Medicine, Center for Dental Medicine, Department of Prosthetic Dentistry, Freiburg, Germany; Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Berlin, Germany
| | - Stevan M Cokic
- KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & UZ Leuven (University Hospitals Leuven), Dentistry, Leuven, Belgium
| | - Benedikt Hache
- University of Freiburg, Faculty of Medicine, Center for Dental Medicine, Department of Prosthetic Dentistry, Freiburg, Germany; University of Freiburg, Faculty of Medicine, Research Center for Tissue Replacement, Regeneration and Neogenesis, Section of Cell biology-inspired Bone Regeneration, G.E.R.N. Freiburg, Germany
| | - Ralf J Kohal
- University of Freiburg, Faculty of Medicine, Center for Dental Medicine, Department of Prosthetic Dentistry, Freiburg, Germany
| | - Brigitte Altmann
- University of Freiburg, Faculty of Medicine, Center for Dental Medicine, Department of Prosthetic Dentistry, Freiburg, Germany; University of Freiburg, Faculty of Medicine, Research Center for Tissue Replacement, Regeneration and Neogenesis, Section of Cell biology-inspired Bone Regeneration, G.E.R.N. Freiburg, Germany
| | - Jef Vleugels
- KU Leuven (University of Leuven), Department of Materials Engineering, Leuven, Belgium
| | - Bart Van Meerbeek
- KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & UZ Leuven (University Hospitals Leuven), Dentistry, Leuven, Belgium
| | - Kerstin Rabel
- University of Freiburg, Faculty of Medicine, Center for Dental Medicine, Department of Prosthetic Dentistry, Freiburg, Germany
| |
Collapse
|
11
|
Atalay P, Öztaş DD. Fatigue resistance and fracture strength of narrow-diameter one-piece zirconia implants with angled abutments. J ESTHET RESTOR DENT 2022; 34:1060-1067. [PMID: 35855644 DOI: 10.1111/jerd.12944] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Revised: 07/05/2022] [Accepted: 07/07/2022] [Indexed: 11/27/2022]
Abstract
OBJECTIVE Zirconia implants are assumed to satisfy the esthetic requirements that titanium implants cannot meet, however, there are not enough studies in the literature about narrow-diameter and angled zirconia implants that can be preferred especially in the anterior region. This in vitro study aimed to evaluate the fatigue resistance and fracture strength of narrow-diameter zirconia implants with angled abutments. MATERIALS AND METHODS Forty-eight one-piece experimental zirconia implants and monolithic zirconia crowns were produced from 3-YTZP blanks. The implant diameters (3.0 or 3.7 mm) and the restoration types were determined according to three intraoral regions (upper central incisors, lower central incisors, and upper canine), and abutments were designed as straight or 15° angled. The samples were subjected to chewing simulation corresponding to 5 years of clinical performance and then the static loading test. The survival rates of groups were measured by the Kaplan-Meier log-rank test, and the fracture load values were estimated by using Kruskal-Wallis and Mann-Whitney U tests (p < 0.05). RESULTS All 3.0 mm diameter implants failed the fatigue test. The fatigue resistance of the implants with angled abutments was significantly lower than the straight abutments, and different crown designs were found to affect survival rates significantly. The fracture strengths of the surviving groups were above the maximum physiological chewing forces, and the differences were not significant. CONCLUSIONS The implant diameter, abutment angle, and restoration type have a significant effect on the fatigue behavior of zirconia implants. CLINICAL SIGNIFICANCE The fracture strengths of the one-piece zirconia implants with a 3.7 mm diameter and a 15° abutment angle are above the chewing forces for the anterior intraoral region.
Collapse
Affiliation(s)
- Pelin Atalay
- Department of Prosthodontics, Faculty of Dentistry, University of Niğde Ömer Halisdemir, Niğde, Turkey
| | - Doğan Derya Öztaş
- Department of Prosthodontics, Faculty of Dentistry, Ankara University, Ankara, Turkey
| |
Collapse
|
12
|
Stability of Cantilever Fixed Dental Prostheses on Zirconia Implants. MATERIALS 2022; 15:ma15103633. [PMID: 35629659 PMCID: PMC9144678 DOI: 10.3390/ma15103633] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Revised: 05/13/2022] [Accepted: 05/16/2022] [Indexed: 01/13/2023]
Abstract
Background: The objective was to determine the optimal connector size and position within zirconia disks for implant-supported cantilever fixed dental prostheses (ICFDP). Methods: Two-unit ICFDPs (n = 60) were designed for the premolar region with connector sizes of either 9 or 12 mm2 and positioned in the enamel or dentin layer of two different types of zirconia disks. The restorations were milled and cemented onto zirconia implants. After simulated chewing for 1.2 Mio cycles, the fracture load was measured and fractures were analyzed. Results: No fractures of ICFDPs or along the implants were detected after simulated aging. The mean fracture load values were significantly higher for a connector size of 9 mm2 (951 N) compared with 12 mm2 (638 N). For the zirconia material with a higher biaxial flexural strength, the fracture load values were increased from 751 to 838 N, but more implant fractures occurred. The position within the zirconia disk did not influence the fracture load. Conclusions: A connector size of 9 mm2 and a zirconia material with a lower strength should be considered when designing ICFDPS on zirconia implants to reduce the risk of fractures along the intraosseous implant portion.
Collapse
|
13
|
Relationships between fracture toughness, Y2O3 fraction and phases content in modern dental Yttria-doped zirconias. Ann Ital Chir 2021. [DOI: 10.1016/j.jeurceramsoc.2021.08.003] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
14
|
Burkhardt F, Spies BC, Riemer L, Adolfsson E, Doerken S, Kohal RJ. Fracture resistance and crystal phase transformation of a one- and a two-piece zirconia implant with and without simultaneous loading and aging-An in vitro study. Clin Oral Implants Res 2021; 32:1288-1298. [PMID: 34352139 DOI: 10.1111/clr.13825] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Revised: 07/12/2021] [Accepted: 07/13/2021] [Indexed: 11/30/2022]
Abstract
OBJECTIVE To evaluate the influence of artificial aging on the transformation propagation and fracture resistance of zirconia implants. METHODS One-piece (with integrated implant abutment, 1P; regular diameter [4.1mm]; n = 16) and two-piece (with separate implant abutment, 2P; wide diameter [5 mm]; n = 16) zirconia implants were embedded according to ISO 14801. A two-piece titanium-zirconium implant (Ti-Zr; 4.1 mm diameter) served as a control (n = 16). One subgroup (n = 8) of each system was simultaneously dynamically loaded (107 cycles; 98N) and hydrothermally aged (85°C, 58 days), while the other subgroup (n = 8) remained untreated. Finally, specimens were statically loaded to fracture. Potential crystal phase transformation was examined at cross sections using scanning electron microscopy (SEM). A multivariate linear regression model was applied for statistical analyses. RESULTS The fracture resistance of 1P (1,117 [SD = 38] N; loaded/aged: 1,009 [60] N), 2P (850 [36] N; loaded/aged: 799 [84] N), and Ti-Zr implants (1,338 [205] N; loaded/aged: 1,319 [247] N) was not affected significantly by loading/aging (p = .171). However, when comparing the systems, they revealed significant differences independent of loading/aging (p ≤ .001). Regarding the crystal structure, a transformation zone was observed in SEM images of 1P only after aging, while 2P showed a transformation zone even before aging. After hydrothermal treatment, an increase of this monoclinic layer was observed in both systems. CONCLUSIONS The Ti-Zr control implant showed higher fracture resistance compared to both zirconia implants. Loading/aging had no significant impact on the fracture resistance of both zirconia implants. The wide-body 2P zirconia implant was weaker than the regular body 1P implant.
Collapse
Affiliation(s)
- Felix Burkhardt
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center - University of Freiburg, Center for Dental Medicine, University of Freiburg, Freiburg, Germany
| | - Benedikt C Spies
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center - University of Freiburg, Center for Dental Medicine, University of Freiburg, Freiburg, Germany
| | - Lennart Riemer
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center - University of Freiburg, Center for Dental Medicine, University of Freiburg, Freiburg, Germany
| | | | - Sam Doerken
- Medical Center - University of Freiburg, Institute for Medical Biometry and Statistics, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Ralf-Joachim Kohal
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center - University of Freiburg, Center for Dental Medicine, University of Freiburg, Freiburg, Germany
| |
Collapse
|
15
|
Juica D, Marcus N, Grandon F, Sanhueza V, Wendler M. Premature failure of a screw-retained ceramic single crown: A clinical report and fractographic analysis. J Prosthet Dent 2020; 127:32-37. [PMID: 33190861 DOI: 10.1016/j.prosdent.2020.06.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Revised: 06/15/2020] [Accepted: 06/15/2020] [Indexed: 10/23/2022]
Abstract
Screw-retained implant-supported ceramic restorations have shown increased rates of technical complications compared with their cemented counterparts, including fracture and chipping of the ceramic structures. The present clinical report identified the causes leading to the catastrophic failure of a screw-retained lithium disilicate veneered crown cemented to a zirconia abutment with a titanium base by using a systematic fractographic approach. A combination of occlusal overloading, a deficient design and inadequate material selection was identified as being responsible for the fracture. These findings highlight the importance of a thorough analysis of the anatomic conditions and loading scenario of screw-retained implant-supported restorations.
Collapse
Affiliation(s)
- Daniel Juica
- Graduate student, Postgraduate Program in Oral and Maxillofacial Implantology, Faculty of Dentistry, University of Concepción, Concepción, Chile
| | - Natalia Marcus
- Assistant Professor, Department of Restorative Dentistry, Faculty of Dentistry, University of Concepción, Concepción, Chile
| | - Fernando Grandon
- Assistant Professor, Department of Restorative Dentistry, Faculty of Dentistry, University of Concepción, Concepción, Chile
| | - Vilma Sanhueza
- Associate Professor, Universidad de Concepción, Instituto de Geología Económica Aplicada (GEA), Concepción, Chile
| | - Michael Wendler
- Assistant Professor, Department of Restorative Dentistry, Faculty of Dentistry, University of Concepción, Concepción, Chile.
| |
Collapse
|
16
|
Jodha KS, Salazar Marocho SM, Scherrer SS, Griggs JA. Fractal analysis at varying locations of clinically failed zirconia dental implants. Dent Mater 2020; 36:1052-1058. [PMID: 32487485 DOI: 10.1016/j.dental.2020.04.021] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2019] [Revised: 04/22/2020] [Accepted: 04/30/2020] [Indexed: 10/24/2022]
Abstract
OBJECTIVES Previous studies have shown that the fracture toughness of ceramics can be determined from the fractal dimensions (D) of their fracture surfaces and that the surface should be leveled to obtain an accurate D measurement. This study was to determine the effects of leveling operations and distance from the failure origin on the D values. METHODS Twelve clinically failed zirconia implants from four different manufacturers: Axis Biodental (n=7), Z-Systems (n=3), Straumann (n=1), and Swiss Dental Solutions (n=1) were obtained from one of the authors and thoroughly cleaned. Epoxy replicas were made of three locations along the crack path in the center region of each fracture surface (near origin (O), hackle (H), and near compression curl (CC)) using a light body polyvinyl siloxane impression material. Surfaces were scanned in ScanAsyst mode with a scan size of 5μm×5μm and a scan rate of 0.592Hz using the atomic force microscope. The surface scans were then leveled using 1st order flattening operation in the AFM analysis software. The height data before and after the operation were imported into a custom MathCAD script, and FRACTALS software was used to determine the D value by Minkowski Cover algorithm, which was shown previously to be the algorithm with the highest precision. A Wilcoxon signed-rank test, two-way repeated-measures ANOVA, and one-way repeated-measures ANOVA were performed as detailed below. RESULTS The data were not normally distributed (S-W p≤0.05), so a non-parametric repeated measures test (Wilcoxon signed-rank test) was selected. The median D values before and after leveling were 2.161 and 2.174, respectively. There was a significant difference before and after leveling (p<0.001). The two-way repeated-measures ANOVA showed no significant difference among the D values for different implant brands (p=0.66) and scanning locations on the fracture surface (p=0.83). After eliminating the implant brand as a factor, the data passed normality and equal variance tests (S-W p=0.88, BF p=0.15). The mean D values and standard deviations from the three locations (O, H, CC) were 2.183±0.031, 2.179±0.024, and 2.175±0.018, respectively. One-way repeated measures ANOVA showed no significant effect of scanning location (p=0.74). SIGNIFICANCE The leveling operation successfully removed the tilt without decreasing surface tortuosity, as it increased the D values significantly. The fractal dimension was the same at the three locations on the fracture surfaces. This means that hackle and compression curl regions can be used to determine fracture toughness when the failure origin has been lost.
Collapse
Affiliation(s)
- Kartikeya S Jodha
- Department of Biomedical Materials Science, University of Mississippi Medical Center, MS, USA
| | - Susana M Salazar Marocho
- University Clinic of Dental Medicine, Division of Fixed Prosthodontics-Biomaterials, University of Geneva, Geneva, Switzerland
| | - Susanne S Scherrer
- University Clinic of Dental Medicine, Division of Fixed Prosthodontics-Biomaterials, University of Geneva, Geneva, Switzerland
| | - Jason A Griggs
- Department of Biomedical Materials Science, University of Mississippi Medical Center, MS, USA.
| |
Collapse
|
17
|
Bethke A, Pieralli S, Kohal RJ, Burkhardt F, von Stein-Lausnitz M, Vach K, Spies BC. Fracture Resistance of Zirconia Oral Implants In Vitro: A Systematic Review and Meta-Analysis. MATERIALS (BASEL, SWITZERLAND) 2020; 13:E562. [PMID: 31991565 PMCID: PMC7040771 DOI: 10.3390/ma13030562] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Revised: 01/15/2020] [Accepted: 01/21/2020] [Indexed: 12/27/2022]
Abstract
Various protocols are available to preclinically assess the fracture resistance of zirconia oral implants. The objective of the present review was to determine the impact of different treatments (dynamic loading, hydrothermal aging) and implant features (e.g., material, design or manufacturing) on the fracture resistance of zirconia implants. An electronic screening of two databases (MEDLINE/Pubmed, Embase) was performed. Investigations including > 5 screw-shaped implants providing information to calculate the bending moment at the time point of static loading to fracture were considered. Data was extracted and meta-analyses were conducted using multilevel mixed-effects generalized linear models (GLMs). The Šidák method was used to correct for multiple testing. The initial search resulted in 1864 articles, and finally 19 investigations loading 731 zirconia implants to fracture were analyzed. In general, fracture resistance was affected by the implant design (1-piece > 2-piece, p = 0.004), material (alumina-toughened zirconia/ATZ > yttria-stabilized tetragonal zirconia polycrystal/Y-TZP, p = 0.002) and abutment preparation (untouched > modified/grinded, p < 0.001). In case of 2-piece implants, the amount of dynamic loading cycles prior to static loading (p < 0.001) or anatomical crown supply (p < 0.001) negatively affected the outcome. No impact was found for hydrothermal aging. Heterogeneous findings of the present review highlight the importance of thoroughly and individually evaluating the fracture resistance of every zirconia implant system prior to market release.
Collapse
Affiliation(s)
- Annalena Bethke
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
| | - Stefano Pieralli
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center—University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany;
| | - Ralf-Joachim Kohal
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center—University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany;
| | - Felix Burkhardt
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center—University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany;
| | - Manja von Stein-Lausnitz
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
| | - Kirstin Vach
- Institute of Medical Biometry and Statistics, Faculty of Medicine, Medical Center—University of Freiburg, University of Freiburg, Stefan-Meier-Str. 26, 79104 Freiburg, Germany;
| | - Benedikt Christopher Spies
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center—University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany;
| |
Collapse
|
18
|
Investigations into the interface failure of yttria partially stabilised zirconia - porcelain dental prostheses through microscale residual stress and phase quantification. Dent Mater 2019; 35:1576-1593. [PMID: 31522759 DOI: 10.1016/j.dental.2019.08.098] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2019] [Accepted: 08/15/2019] [Indexed: 11/22/2022]
Abstract
OBJECTIVES Yttria Partially Stabilised Zirconia (YPSZ) is a high strength ceramic which has become widely used in porcelain veneered dental copings due to its exceptional toughness. Within these components the residual stress and crystallographic phase of YPSZ close to the interface are highly influential in the primary failure mode; near interface porcelain chipping. In order to improve present understanding of this behaviour, characterisation of these parameters is needed at an improved spatial resolution. METHODS In this study transmission micro-focus X-ray Diffraction, Raman spectroscopy, and focused ion beam milling residual stress analysis techniques have, for the first time, been used to quantify and cross-validate the microscale spatial variation of phase and residual stress of YPSZ in a prosthesis cross-section. RESULTS The results of all techniques were found to be comparable and complementary. Monoclinic YPSZ was observed within the first 10μm of the YPSZ-porcelain interface with a maximum volume fraction of 60%. Tensile stresses were observed within the first 150 μm of the interface with a maximum value of ≈300 MPa at 50 μm from the interface. The remainder of the coping was in mild compression at ≈-30MPa, with shear stresses of a similar magnitude also being induced by the YPSZ phase transformation. SIGNIFICANCE The analysis indicates that the interaction between phase transformation, residual stress and porcelain creep at YPSZ-porcelain interface results in a localised porcelain fracture toughness reduction. This explains the increased propensity of failure at this location, and can be used as a basis for improving prosthesis design.
Collapse
|