Wang Y, Wu Z, Wang T, Tang W, Li T, Xu H, Sun H, Lin Y, Tonin BSH, Ye Z, Fu J. Bioactive Dental Resin Composites with MgO Nanoparticles. ACS Biomater Sci Eng 2023; 9:4632-4645. [PMID: 37486960 DOI: 10.1021/acsbiomaterials.3c00490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/26/2023]
Abstract
Photoactivating dental resin composites have been the most prevailing material for repairing dental defects in various clinical scenarios due to their multiple advantages. However, compared to other restorative materials, the surface of resin-based composites is more susceptible to plaque biofilm accumulation, which can lead to secondary caries and restoration failure. This study introduced different weight fractions (1, 2, 5, 10, and 15%) of magnesium oxide nanoparticles (MgONPs) as antibacterial fillers into dental resin composites. Multifarious properties of the material were investigated, including antibacterial activity against a human salivary plaque-derived biofilm, cytotoxicity on human gingival fibroblasts, mechanical and physicochemical properties as well as the performance when subjected to thermocycling aging treatment. Results showed that the incorporation of MgONPs significantly improved the composites' anti-biofilm capability even at a low amount of 2 wt % without compromising the mechanical, physicochemical, and biocompatibility performances. The results of the thermocycling test suggested certain of aging resistance. Moreover, a small amount of MgONPs possibly made a difference in enhancing photoactivated polymerization and increasing the curing depth of experimental resin composites. Overall, this study highlights the potential of MgONPs as an effective strategy for developing antibacterial resin composites, which may help mitigating cariogenic biofilm-associated secondary caries.
Collapse
Affiliation(s)
- Yuan Wang
- Department of Prosthodontics, The Affiliated Hospital of Qingdao University, Qingdao 266000, P. R. China
- School of Stomatology, Qingdao University, Qingdao 266003, P. R. China
| | - Zhongyuan Wu
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, P. R. China
| | - Ting Wang
- School of Stomatology, Qingdao University, Qingdao 266003, P. R. China
| | - Weilong Tang
- Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR 999077, P. R. China
| | - Tingting Li
- Department of Prosthodontics, The Affiliated Hospital of Qingdao University, Qingdao 266000, P. R. China
- School of Stomatology, Qingdao University, Qingdao 266003, P. R. China
| | - Haiping Xu
- Department of Prosthodontics, The Affiliated Hospital of Qingdao University, Qingdao 266000, P. R. China
- School of Stomatology, Qingdao University, Qingdao 266003, P. R. China
| | - Hui Sun
- School of Stomatology, Qingdao University, Qingdao 266003, P. R. China
| | - Yifan Lin
- Division of Paediatric Dentistry and Orthodontics, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR 999077, P. R. China
| | - Bruna S H Tonin
- Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirao Preto, University of Sao Paulo, Ribeirao Preto 14040904, SP, Brazil
| | - Zhou Ye
- Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR 999077, P. R. China
| | - Jing Fu
- Department of Prosthodontics, The Affiliated Hospital of Qingdao University, Qingdao 266000, P. R. China
- School of Stomatology, Qingdao University, Qingdao 266003, P. R. China
| |
Collapse
|
2
|
Maucoski C, Price RB, Arrais CAG. Temperature changes and hardness of resin-based composites light-cured with laser diode or light-emitting diode curing lights. Odontology 2023; 111:387-400. [PMID: 36184680 DOI: 10.1007/s10266-022-00745-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Accepted: 09/13/2022] [Indexed: 11/25/2022]
Abstract
The temperature and Vickers Hardness (VH) at the top and bottom surfaces of three resin-based composites (RBCs) were measured when light-cured using five light-curing units (LCUs). The spectrum, power, and energy delivered to the top of the RBCs and transmitted through the RBCs were measured. Starting at 32℃, the temperature rise produced by the Monet Laser (ML-1 s and 3 s), Valo Grand (VG-3 s and 10 s), DeepCure (DC-10 s), PowerCure, (PC-3 s and 10 s) and PinkWave (PW-10 s) were measured at the bottom of specimens 2 mm deep × 6 mm wide made of Filtek Universal A2, Tetric Evoceram A2 and an experimental RBC codenamed Transcend UB. The VH values measured at the top and bottom of these RBCs were analyzed using ANOVA and Scheffe's post hoc test (p < 0.05) to determine the effects of the LCUs on the RBCs. The transmitted power from the ML was reduced by 77.4% through 2 mm of Filtek Universal, whereas light from PW decreased by only 36.8% through Transcend. The highest temperature increases from the LCU combined with the exothermic reaction occurred for Transcend, and overall, no significant differences were detected between Filtek Universal and Tetric Evoceram (p = 0.9756). Transcend achieved the highest VH values at the top and bottom surfaces. The PinkWave used for 10 s produced the largest temperature increase (20.2℃) in Transcend. The Monet used for 1 s produced the smallest increase (7.8℃) and the lowest bottom:top VH ratios.
Collapse
Affiliation(s)
- Cristiane Maucoski
- Department of Dental Clinical Sciences, Dalhousie University, Halifax, NS, B3H 4R2, Canada.
- Department of Restorative Dentistry, The State University of Ponta Grossa, 4748 General Carlos Cavalcanti Av., Ponta Grossa, Parana, 84051-130, Brazil.
| | - Richard Bengt Price
- Department of Dental Clinical Sciences, Dalhousie University, Halifax, NS, B3H 4R2, Canada
| | - Cesar Augusto Galvão Arrais
- Department of Restorative Dentistry, The State University of Ponta Grossa, 4748 General Carlos Cavalcanti Av., Ponta Grossa, Parana, 84051-130, Brazil
| |
Collapse
|
3
|
Maucoski C, Price RB, Rocha MG, Roulet JF, Sullivan B. Ability of short exposures from laser and quad-wave curing lights to photo-cure bulk-fill resin-based composites. Dent Mater 2023; 39:275-292. [PMID: 36868892 DOI: 10.1016/j.dental.2023.01.007] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Revised: 01/10/2023] [Accepted: 01/25/2023] [Indexed: 03/05/2023]
Abstract
OBJECTIVE This study investigated the ability of a laser, and a 'quad-wave' LCU, to photo-cure paste and flowable bulk-fill resin-based composites (RBCs). METHODS Five LCUs and nine exposure conditions were used. The laser LCU (Monet) used for 1 s and 3 s, the quad-wave LCU (PinkWave) used for 3 s in the Boost and 20 s in the Standard modes, the the multi-peak LCU (Valo X) used for 5 s in the Xtra and 20 s in the Standard modes, were compared to the polywave PowerCure used in the 3 s mode and for 20 s in the Standard mode, and to the mono-peak SmartLite Pro used for 20 s. Two paste consistency bulk-fill RBCs: Filtek One Bulk Fill Shade A2 (3 M), Tetric PowerFill Shade IVA (Ivoclar Vivadent), and two flowable RBCs: Filtek Bulk Fill Flowable Shade A2 (3 M), Tetric PowerFlow Shade IVA (Ivoclar Vivadent) were photo-cured in 4-mm deep x 4-mm diameter metal molds. The light received by these specimens was measured using a spectrometer (Flame-T, Ocean Insight), and the radiant exposure delivered to the top surface of the RBCs was mapped. The immediate degree of conversion (DC) at the bottom, and the 24-hour Vickers Hardness (VH) at the top and bottom of the RBCs were measured and compared. RESULTS The irradiance received by the 4-mm diameter specimens ranged from 1035 mW/cm2 (SmartLite Pro) to 5303 mW/cm2 (Monet). The radiant exposures between 350 and 500 nm delivered to the top surface of the RBCs ranged from 5.3 J/cm2 (Monet in 1 s) to 26.4 J/cm2 (Valo X), although the PinkWave delivered 32.1 J/cm2 in 20 s 350 to 900 nm. All four RBCs achieved their maximum DC and VH values at the bottom when photo-cured for 20 s. The Monet used for 1 s and the PinkWave used for 3 s on the Boost setting delivered the lowest radiant exposures between 420 and 500 nm (5.3 J/cm2 and 3.5 J/cm2 respectively), and they produced the lowest DC and VH values. CONCLUSIONS Despite delivering a high irradiance, the short 1 or 3-s exposures delivered less energy to the RBC than 20-s exposures from LCUs that deliver> 1000 mW/cm2. There was an excellent linear correlation (r > 0.98) between the DC and the VH at the bottom. There was a logarithmic relationship between the DC and the radiant exposure (Pearson's r = 0.87-97) and between the VH and the radiant exposure (Pearson's r = 0.92-0.96) delivered in the 420-500 nm range.
Collapse
Affiliation(s)
- Cristiane Maucoski
- Department of Restorative Dentistry, State University of Ponta Grossa, Ponta Grossa, Parana, Brazil; Department of Dental Clinical Sciences, Dalhousie University, Faculty of Dentistry, Halifax, Nova Scotia, Canada
| | - Richard Bengt Price
- Department of Dental Clinical Sciences, Dalhousie University, Faculty of Dentistry, Halifax, Nova Scotia, Canada.
| | - Mateus Garcia Rocha
- Department of Restorative Dental Science, Center of Dental Biomaterials College of Dentistry, University of Florida, Gainesville, FL, USA
| | - Jean-François Roulet
- Department of Restorative Dental Science, Center of Dental Biomaterials College of Dentistry, University of Florida, Gainesville, FL, USA
| | - Braden Sullivan
- Department of Restorative Dentistry, State University of Ponta Grossa, Ponta Grossa, Parana, Brazil
| |
Collapse
|
4
|
Braga S, Schettini A, Carvalho E, Shimokawa C, Price RB, Soares CJ. Effect of the Sample Preparation and Light-curing Unit on the Microhardness and Degree of Conversion of Bulk-fill Resin-based Composite Restorations. Oper Dent 2022; 47:163-172. [PMID: 35604828 DOI: 10.2341/20-043-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/16/2020] [Indexed: 11/23/2022]
Abstract
OBJECTIVE To evaluate the effect of the sample preparation and light-curing units (LCUs) on the Knoop hardness (KH, N/mm2) and degree of conversion (DC, %) of bulk-fill resin-based composite restorations. METHODS Two molds were made using human molar teeth embedded in acrylic resin. One was a conventional tooth mold where the molar received a mesio-occluso-distal (MOD) preparation. In the other, the tooth was sectioned in three slices (buccal, middle, and lingual). The center slice received a MOD preparation similar to the conventional mold. Both tooth molds were placed in the second mandibular molar position in a Dentoform with a 44-mm interincisal opening. Restorations were made using Opus Bulk Fill (FGM) high viscosity bulk-fill resin-based composite (RBC) and light cured using two different lights: VALO Cordless (Ultradent) and Bluephase G2 (Ivoclar Vivadent). The RBC was placed in one increment that was light-cured for a total of 80 seconds (40 seconds at the occluso-mesial and occluso-distal locations). The RBC specimens were then prepared as follows: EmbPol - tooth mold specimen was embedded in polystyrene resin and polished before testing; Pol - tooth mold specimen was not embedded, but was polished before testing; NotPol - sectioned tooth mold, specimen not embedded nor polished before testing. The KH was measured in different depths and regions of the specimens, and the DC was measured using Raman spectroscopy. RESULTS The results were analyzed using a 2-way analysis of variance (ANOVA) or repeated measures followed by the Tukey posthoc test (α=0.05). The preparation method (p<0.001), depth of restoration (p<0.001), and the interaction between method and depth (p=0.003) all influenced the KH values. Preparation method (p<0.001), tooth region (p<0.001), and the interaction between method and tooth region (p=0.002) all influenced DC values. The KH values were reduced significantly from the top to the bottom of the restorations and also at the proximal box when compared with the occlusal region. This outcome was most significant in the proximal boxes. The NotPol method was the most effective method to detect the effect of differences in KH or DC within the restoration. A lower DC and KH were found at the gingival regions of the proximal boxes of the restorations. When the KH and DC values were compared, there were no significant differences between the LCUs (KH p=0.4 and DC p=0.317). CONCLUSION Preparation methods that embedded the samples in polystyrene resin and polished the specimens reduced the differences between the KH and DC values obtained by different preparation techniques. The NotPol method was better able to detect differences produced by light activation in deeper areas.
Collapse
Affiliation(s)
- Ssl Braga
- Stella Sueli Lourenço Braga, DDS, MSc, PhD, Department of Operative Dentistry and Dental Materials, Dental School, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil
| | - Act Schettini
- Ana Cecília Teodoro Schettini, DDS, Department of Operative Dentistry and Dental Materials, Dental School, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil
| | - Elo Carvalho
- Everton Luiz Oliveira Carvalho, DDS, Department of Operative Dentistry and Dental Materials, Dental School, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil
| | - Cak Shimokawa
- Carlos Alberto Kenji Shimokawa, DDS, MSc, PhD, professor, Department of Restorative Dentistry, Dental School, University of São Paulo, São Paulo, São Paulo, Brazil
| | - R B Price
- Richard Bengt Price, DDS, MSc, PhD, professor, Department of Dental Clinical Sciences, Dalhousie University, Halifax, Nova Scotia, Canada
| | - C J Soares
- *Carlos José Soares, DDS, MSc, PhD, Professor and Chair at Department of Operative Dentistry and Dental Materials, Dental School, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil
| |
Collapse
|
5
|
Sochacki S, Karczewski A, Platt J, Roberts HW. Effect of post-irradiation polymerization on selected mechanical properties of six direct resins. Dent Mater J 2021; 41:230-240. [PMID: 34789623 DOI: 10.4012/dmj.2021-175] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This study evaluated the post-irradiation mechanical property development of six resin composite-based restorative materials from the same manufacturer starting at 1 h post irradiation, followed by 24 h, 1 week, and 1 month after fabrication. Samples were stored in 0.2M phosphate buffered saline until testing. Flexural strength, flexural modulus, flexural toughness, modulus of resiliency, fracture toughness, and surface microhardness were performed at each time interval. Mean data was analyzed by Kruskal Wallis and Dunn's post hoc testing at a 95% level of confidence (α=0.05). Results were material specific but overall, all resin composite material mechanical properties were found to be immature at 1 h after polymerization as compared to that observed at 24 h. It may be prudent that clinicians advise patients, especially those receiving complex posterior composite restorations, to guard against overly stressing these restorations during the first 24 h.
Collapse
Affiliation(s)
- Sabrina Sochacki
- Department of Biomedical Sciences and Comprehensive Care, School of Dentistry, Indiana University
| | - Ashley Karczewski
- Department of Biomedical Sciences and Comprehensive Care, School of Dentistry, Indiana University
| | - Jeffrey Platt
- Department of Biomedical Sciences and Comprehensive Care, School of Dentistry, Indiana University
| | - Howard W Roberts
- Director of Graduate Studies, University of Kentucky, College of Dentistry
| |
Collapse
|
6
|
Algamaiah H, Watts DC. Post-irradiation surface viscoelastic integrity of photo-polymerized resin-based composites. Dent Mater 2021; 37:1828-1833. [PMID: 34593246 DOI: 10.1016/j.dental.2021.09.012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2021] [Revised: 09/13/2021] [Accepted: 09/13/2021] [Indexed: 11/24/2022]
Abstract
OBJECTIVE A class of ultra-rapid-cure resin-based composites (RBCs) exhibited immediate post-irradiation surface viscoelastic integrity using an indentation-creep/recovery procedure. The aim of this study was to determine whether such behavior is more generally characteristic of a wider range of RBCs. METHODS Eight representative RBCs were selected based on different clinical categories: three bulkfills (OBF, Filtek One Bulk Fill; VBF, Venus Bulkfill; EBF, Estelite Bulkfill), three conventional non-flowables (XTE, Filtek Supreme XTE; GSO, GrandioSo; HRZ, Harmonize) and conventional flowables (XTF, Filtek Supreme XTE Flow; GSF, GrandioSo Flow). Stainless steel split molds were used to fabricate cylindrical specimens (4mm (dia)×4mm). These were irradiated (1.2W/cm2) for 20s on the top surface. Post-irradiation specimens (n=3), within their molds, were centrally loaded with a flat-ended 1.5mm diameter indenter under 14MPa stress: either immediately (<2min) or after 24h delayed indentation. Stress was maintained for 2h, then - after removal - recovery measurements continued for a further 2h. Indentation depth (%) versus time was measured continuously to an accuracy of <0.1μm. Data were analyzed by One-way ANOVA and Tukey post-hoc tests (α=0.05). RESULTS Time-dependent viscoelastic indentation was observed for all RBCs. For immediate indentation, the maximum indentation range was 1.43-4.92%, versus 0.70-2.22% for 24h delayed indentation. Following 2h recovery, the residual indentation range was 0.86-3.58% after immediate indentation, reducing to 0.22-1.27% for delayed indentation. The greatest immediate indentation was shown by VBF followed by XTF and GSF. OBF, HRZ, XTE and GSO had significantly lower indentations (greater hardness). XTE showed a significantly reduced indentation maximum compared to OBF (p<0.05). Indentations delayed until 24h post-irradiation were reduced (p<0.05) for most materials. SIGNIFICANCE The indentation-creep methodology effectively characterized resin-based composites within several categories. Viscoelastic properties evaluated by the indentation-creep method confirmed that highly filled RBCs were more resistant to indentation. Indentations were reduced after 24h post-irradiation due to further matrix-network development.
Collapse
Affiliation(s)
- Hamad Algamaiah
- Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK; Department of Restorative Dental Science, College of Dentistry, King Saud University, Riyadh, Saudi Arabia.
| | - David C Watts
- Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK; Photon Science Institute, University of Manchester, Manchester, UK.
| |
Collapse
|
7
|
Gebril M, Grüll MP, Brillant MS, Sullivan B, Price RB. Effect of repeated heating and cooling cycles on the degree of conversion and microhardness of four resin composites. J ESTHET RESTOR DENT 2021; 33:1201-1209. [PMID: 34424606 DOI: 10.1111/jerd.12815] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2021] [Revised: 08/06/2021] [Accepted: 08/09/2021] [Indexed: 11/28/2022]
Abstract
OBJECTIVE This study evaluated the effect of repeatedly heating and cooling four resin-based composites (RBCs) for up to six cycles. MATERIALS AND METHODS Four commercial RBCs were heated to 68°C and cooled to room temperature for up to six cycles before photocuring at 30°C. Specimens spent a total of 0, 30, 60, 90, 120, 150 min, or 7 days at 68°C. The degree of conversion (DC) was measured at the bottom of the specimens immediately after photocuring. The Vickers microhardness was measured at the top and bottom of the RBC surfaces 24 h after photocuring. The data were analyzed using one-way analysis of variance, Dunnett's or Bonferroni post-hoc tests, and Spearman correlation analysis (α = 0.05). RESULTS For two brands of RBC, the DC decreased at various time points; however, these decreases were small, and there was no correlation (negative or positive) between the number of heating cycles and the DC for any of the RBCs. Repeated heated and cooling resulted in small changes in the hardness (compared to the control) in both directions (Dunnett; p < 0.05). Two of the RBCs showed a significant, positive correlation between the number of heating cycles and their hardness at the bottom surface. CONCLUSION Repeated heating, cooling, and then reheating the RBCs for up to 1 week had little overall effect on their DC and microhardness values. The 2 mm thick specimens of all four RBCs achieved a bottom: top hardness ratio exceeding 0.8 after a 20 s exposure to light from a commercial LED curing light CLINICAL SIGNIFICANCE: Six repeated dry heating and cooling cycles of up to 1 week in duration had little effect on the DC and the microhardness of four commercial resin-based composites.
Collapse
Affiliation(s)
- Mohamed Gebril
- Department of Dental Clinical Sciences, Faculty of Dentistry, Dalhousie University, Halifax, Canada
| | - Marc P Grüll
- Faculty of Dentistry, Dalhousie University, Halifax, Canada
| | | | | | - Richard B Price
- Department of Dental Clinical Sciences, Faculty of Dentistry, Dalhousie University, Halifax, Canada
| |
Collapse
|
8
|
Taylor R, Fuentealba R, Brackett WW, Roberts HW. 24 hour polymerization shrinkage of resin composite core materials. J ESTHET RESTOR DENT 2021; 33:775-785. [PMID: 34060198 DOI: 10.1111/jerd.12788] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 04/20/2021] [Accepted: 05/06/2021] [Indexed: 12/01/2022]
Abstract
PURPOSE The study's purpose was to evaluate the 24-hour polymerization shrinkage of resin composite core materials. MATERIAL AND METHODS Eleven resin composite core material samples (n = 12) were evaluated using a non-contact imaging device with measurements obtained over 24 h. Shrinkage values were determined corresponding to proposed times involved with CAD/CAM same-day treatment and at 24 h. Shrinkage data was statistically compared using Friedman/Dunn's test for intragroup analysis and Kruskal Wallis/Dunn's test for intergroup analysis, all at a 95% level of confidence (α = 0.05). RESULTS Mean results identified a wide volumetric shrinkage range with considerable similarity overlap. Inconsistent shrinkage behavior was evident and all materials reached maximum values before 24 h. No significant difference was observed during proposed digital same day all ceramic crown procedures, but some differences were noted at 24 h. CONCLUSIONS Under this study's conditions results were material specific, at times inconsistent, with wide variation. Shrinkage consistently increased for all products and it is not known if the continued shrinkage magnitude may compromise the stability and fit of all-ceramic crowns at 24 h.
Collapse
Affiliation(s)
- Robert Taylor
- Division of Comprehensive Care, University of Kentucky College of Dentistry, Lexington, Kentucky, USA
| | - Rodrigo Fuentealba
- Division of Prosthodontics, University of Kentucky College of Dentistry, Lexington, Kentucky, USA
| | - William W Brackett
- Operative Dentistry and Fixed Prosthodontics, Department of Restorative Sciences, Dental College of Georgia, Augusta, Georgia, USA
| | - Howard W Roberts
- Director of Graduate Studies, University of Kentucky College of Dentistry, Lexington, Kentucky, USA.,Comprehensive Dentistry, Uniformed Services University of the Health Sciences Postgraduate Dental School, Bethesda, Maryland, USA
| |
Collapse
|
9
|
Watts DC, Algamaiah H. Characterizing surface viscoelastic integrity of ultra-fast photo-polymerized composites: Methods development. Dent Mater 2020; 36:1255-1265. [PMID: 32819731 DOI: 10.1016/j.dental.2020.07.009] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Revised: 07/28/2020] [Accepted: 07/28/2020] [Indexed: 11/26/2022]
Abstract
OBJECTIVE Resin-Composites are now available designed for polymerization using 3 s of intense light irradiation. The aim was to develop an experimental method to probe their surface viscoelastic integrity immediately following such rapid photo-cure via macroscopic surface indentation under constant stress as a function of time. METHODS Two bulk-fill composites (Ivoclar AG) were studied: Tetric PowerFill (PFill) and PowerFlow (PFlow). Split molds were used to fabricate cylindrical {4 mm (dia) × 4 mm} paste specimens, irradiated at 23 °C at 0 mm from the top surface with a BluephasePowerCure LED-LCU, with 3 s or 5 s modes, emitting 3 and 2 W/cm2, respectively. Post-irradiation specimens were immediately transferred to an apparatus equipped with a flat-ended indentor of 1.5 mm diameter. 14 MPa compressive stress at the indentor tip was applied centrally in < 2 min and maintained constant for 2 h. Indentation (I) magnitudes were recorded in real-time (t), with I(t) data re-expressed as % indentation relative to the 4 mm specimen height. After 2 h, the indentor was unloaded and indentation recovery was monitored for a further 2 h. Parallel sets of measurements were made where indentation was delayed for 24 h. Further measurements were made with more conventional composites: EvoCeram Bulk Fill (ECeram) and Tetric EvoFlow Bulk Fill (EFlow). These were irradiated for 20 s at 1.2 W/cm2. Kinetic data were curve-fitted to exponential growth functions and key parameters analyzed by ANOVA and post-hoc tests (α = 0.05). RESULTS I(t) plots looked initially similar to bulk creep/recovery: rapid deformation plus viscoelastic response; then, upon unloading: rapid (elastic) recovery followed by partial viscoelastic recovery. However, unlike multiply irradiated and stored bulk-creep specimens, the present specimens were exposed to only 3 or 5 s "occlusal" irradiation; generating "hard" surfaces. Subsequently, during the 2 h indentation, the polymer matrix network continued to harden and consolidate. Upon initial loading, I(t) reached 2-3% indentation, depending upon the formulation. Upon unloading at 2 h, elastic recovery was only ca. 1 %. Delayed loading for 24 h, generated I(t) plots of significantly reduced magnitude. Most importantly, however, the I(t) plots for ECeram and EFlow, after 20 s irradiation, showed I(t) magnitudes quite comparable to the PFill and PFlow rapid-cure composites. SIGNIFICANCE Macroscopic indentation creep has been shown to be a workable procedure that can be applied to rapid-cure materials to assess their immediate surface integrity and developing viscoelastic characteristics. The applied stress of 14 MPa was relatively severe and the indentation/recovery profiles of PowerFill materials with only 3 or 5 s irradiation demonstrated comparability with their established 20 s cure siblings, evidencing the suitability of the PowerCure system for clinical application.
Collapse
Affiliation(s)
- David C Watts
- Biomaterials Science, Division of Dentistry, School of Medical Sciences, University of Manchester, UK; Photon Science Institute, University of Manchester, UK.
| | - Hamad Algamaiah
- Biomaterials Science, Division of Dentistry, School of Medical Sciences, University of Manchester, UK; Department of Restorative Dental Science, College of Dentistry, King Saud University, Saudi Arabia.
| |
Collapse
|