Iliadi A, Zervou SK, Koletsi D, Schätzle M, Hiskia A, Eliades T, Eliades G. Surface alterations and compound release from aligner attachments in vitro. Eur J Orthod 2024; 46:cjae026. [PMID: 38884540 PMCID: PMC11181360 DOI: 10.1093/ejo/cjae026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/18/2024]
Abstract
AIM The aim of the present study was to assess the alterations in morphology, roughness, and composition of the surfaces of a conventional and a flowable composite attachment engaged with aligners, and to evaluate the release of resin monomers and their derivatives in an aqueous environment. METHODS Zirconia tooth-arch frames (n = 20) and corresponding thermoformed PET-G aligners with bonded attachments comprising two composite materials (universal-C and flowable-F) were fabricated. The morphological features (stereomicroscopy), roughness (optical profilometry), and surface composition (ATR-FTIR) of the attachments were examined before and after immersion in water. To simulate intraoral use, the aligners were removed and re-seated to the frames four times per day for a 7-day immersion period. After testing, the eluents were analyzed by LC-MS/MS targeting the compounds Bis-GMA, UDMA, 2-HEMA, TEGDMA and BPA and by LC-HRMS for suspect screening of the leached dental material compounds and their degradation products. RESULTS After testing, abrasion-induced defects were found on attachment surfaces such as scratches, marginal cracks, loss of surface texturing, and fractures. The morphological changes and debonding rate were greater in F. Comparisons (before-after testing) revealed a significantly lower Sc roughness parameter in F. The surface composition of the aligners after testing showed minor changes from the control, with insignificant differences in the degree of C = C conversion, except for few cases with strong evidence of hydrolytic degradation. Targeted analysis results revealed a significant difference in the compounds released between Days 1 and 7 in both materials. Insignificant differences were found when C was compared with F in both timeframes. Several degradation products were detected on Day 7, with a strong reduction in the concentration of the targeted compounds. CONCLUSIONS The use of aligners affects the surface characteristics and degradation rate of composite attachments in an aqueous environment, releasing monomers, and monomer hydrolysates within 1-week simulated use.
Collapse
Affiliation(s)
- Anna Iliadi
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Greece
- Faculty of Medicine and Health Technology, University of Tampere, Finland
| | - Sevasti-Kiriaki Zervou
- Photo-Catalytic Processes and Environmental Chemistry, Institute of Nanoscience and Nanotechnology, National Centre for Scientific Research ‘Demokritos’, Athens, Greece
| | - Despina Koletsi
- Clinic of Orthodontics and Pediatric Dentistry, Center for Dental Medicine, University of Zurich, Switzerland
- Meta-Research Innovation Center at Stanford (METRICS), Stanford University, CA, USA
| | - Marc Schätzle
- Clinic of Orthodontics and Pediatric Dentistry, Center for Dental Medicine, University of Zurich, Switzerland
| | - Anastasia Hiskia
- Photo-Catalytic Processes and Environmental Chemistry, Institute of Nanoscience and Nanotechnology, National Centre for Scientific Research ‘Demokritos’, Athens, Greece
| | - Theodore Eliades
- Clinic of Orthodontics and Pediatric Dentistry, Center for Dental Medicine, University of Zurich, Switzerland
| | - George Eliades
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Greece
| |
Collapse
|
2
|
Chen WC, Chuang SF, Tseng PC, Lai TW, Chen TYF, Sun YN. Assessments of polymerization shrinkage by optical coherence tomography-based digital image correlation analysis-Part I: Parameter identification. Dent Mater 2024; 40:958-965. [PMID: 38729780 DOI: 10.1016/j.dental.2024.05.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 04/27/2024] [Accepted: 05/03/2024] [Indexed: 05/12/2024]
Abstract
OBJECTIVE To investigate the feasibility of optical coherence tomography (OCT)-based digital image correlation (DIC) analysis and to identify the experimental parameters for measurements of polymerization shrinkage. METHODS Class I cavities were prepared on bovine incisors and filled with Filtek Z350XT Flowable (Z350F). One OCT image of the polymerized restoration was processed to generate virtually displaced images. In addition, the tooth specimen was physically moved under OCT scanning. A DIC software analyzed these virtual and physical transformation sets and assessed the effects of subset sizes on accuracy. The refractive index of unpolymerized and polymerized Z350F was measured via OCT images. Finally, different particles (70-80 µm glass beads, 150-212 µm glass beads, and 75-150 µm zirconia powder) were added to Z350F to inspect the analyzing quality. RESULTS The analyses revealed a high correlation (>99.99%) for virtual movements within 131 pixels (639 µm) and low errors (<5.21%) within a 10-µm physical movement. A subset size of 51 × 51 pixels demonstrated the convergence of correlation coefficients and calculation time. The refractive index of Z350F did not change significantly after polymerization. Adding glass beads or zirconia particles caused light reflection or shielding in OCT images, whereas blank Z350F produced the best DIC analysis results. SIGNIFICANCE The OCT-based DIC analysis with the experimental conditions is feasible in measuring polymerization shrinkage of RBC restorations. The subset size in the DIC analysis should be identified to optimize the analysis conditions and results. Uses of hyper- or hypo-reflective particles is not recommended in this method.
Collapse
Affiliation(s)
- Wei-Chi Chen
- School of Dentistry and Institute of Oral Medicine, National Cheng Kung University, Tainan, Taiwan; Department of Dentistry, Sin-Lau Hospital, Tainan, Taiwan
| | - Shu-Fen Chuang
- School of Dentistry and Institute of Oral Medicine, National Cheng Kung University, Tainan, Taiwan; Department of Stomatology, National Cheng Kung University Hospital, Tainan, Taiwan.
| | - Po-Chun Tseng
- Department of Conservative Dentistry and Periodontology, University Hospital, LMU Munich, Munich, Germany
| | - Ting-Weng Lai
- School of Dentistry and Institute of Oral Medicine, National Cheng Kung University, Tainan, Taiwan; Department of Stomatology, National Cheng Kung University Hospital, Tainan, Taiwan
| | - Terry Yuan-Fang Chen
- Department of Mechanical Engineering, National Cheng Kung University, Tainan, Taiwan
| | - Yung-Nien Sun
- Department of Computer Science and Information Engineering, National Cheng Kung University, Tainan, Taiwan
| |
Collapse
|
3
|
Miranda SB, Lins RBE, Santi MR, Denucci GC, Silva CCS, da Silva SDFF, Marques DDAV, Montes MAJR. Effect of Rapid High-Intensity Light-Curing on Increasing Transdentinal Temperature and Cell Viability: An In Vitro Study. Polymers (Basel) 2024; 16:1466. [PMID: 38891413 PMCID: PMC11175155 DOI: 10.3390/polym16111466] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2024] [Revised: 05/17/2024] [Accepted: 05/18/2024] [Indexed: 06/21/2024] Open
Abstract
BACKGROUND This study investigated effects of rapid high-intensity light-curing (3 s) on increasing transdentinal temperature and cell viability. METHODS A total of 40 dentin discs (0.5 mm) obtained from human molars were prepared, included in artificial pulp chambers (4.5 × 5 mm), and subjected to four light-curing protocols (n = 5), with a Valo Grand light curing unit: (i) 10 s protocol with a moderate intensity of 1000 mW/cm2 (Valo-10 s); (ii) 3 s protocol with a high intensity of 3200 mW/cm2 (Valo-3 s); (iii) adhesive system + Filtek Bulk-Fill Flow bulk-fill composite resin in 10 s (FBF-10 s); (iv) adhesive system + Tetric PowerFlow bulk-fill composite resin in 3 s (TPF-3 s). Transdentinal temperature changes were recorded with a type K thermocouple. Cell viability was assessed using the MTT assay. Data were analyzed using one-way ANOVA and Tukey tests for comparison between experimental groups (p < 0.05). RESULTS The 3 s high-intensity light-curing protocol generated a higher temperature than the 10 s moderate-intensity standard (p < 0.001). The Valo-10 s and Valo-3 s groups demonstrated greater cell viability than the FBF-10s and TPF-3 s groups and statistical differences were observed between the Valo-3 s and FBF-10 s groups (p = 0.023) and Valo-3 s and TPF-3 s (p = 0.025), with a potential cytotoxic effect for the FBF-10 s and TPF-3 s groups. CONCLUSIONS The 3 s rapid high-intensity light-curing protocol of bulk-fill composite resins caused a temperature increase greater than 10 s and showed cell viability similar to and comparable to the standard protocol.
Collapse
Affiliation(s)
| | | | - Marina Rodrigues Santi
- Piracicaba Dental School, University of Campinas, Piracicaba 13414-018, São Paulo, Brazil;
| | - Giovanna Corrêa Denucci
- Department of Cariology and Operative Dentistry, Indiana University School of Dentistry, Indianapolis, IN 46202, USA;
| | - Cleyton Cézar Souto Silva
- Department of Clinical Nurse, Federal University of Paraiba, João Pessoa 58058-600, Paraíba, Brazil;
| | | | | | | |
Collapse
|
4
|
Klarić E, Bosnić JV, Par M, Tarle Z, Marovic D. One-Year Evaluation of High-Power Rapid Curing on Dentin Bond Strength. MATERIALS (BASEL, SWITZERLAND) 2024; 17:2297. [PMID: 38793364 PMCID: PMC11122907 DOI: 10.3390/ma17102297] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2024] [Revised: 05/07/2024] [Accepted: 05/10/2024] [Indexed: 05/26/2024]
Abstract
This study investigated the effect of 3 s light-curing with a high-power LED curing unit on the shear bond strength of bulk-fill composites. Four bulk-fill composites were bonded to dentin with a universal adhesive (Scotchbond Universal Plus): two materials designed for rapid curing (Tetric PowerFill and Tetric PowerFlow) and two controls (Filtek One Bulk Fill Restorative and SDR Plus Bulk Fill Flowable). The 4 mm composite layer was light-cured with Bluephase PowerCure for 20 s at 1000 mW/cm2 ("20 s") or for 3 s at 3000 mW/cm2 ("3 s"). The samples were stored at 37 °C in distilled water and tested after 1, 6 and 12 months. The samples polymerised in the "3 s" mode had statistically similar or higher bond strength than the samples cured in "20 s" mode, except for the Tetric PowerFlow (1 month) and SDR+ (6 month). The flowable materials Tetric PowerFlow and SDR Plus initially showed the highest values in the "3 s" and "20 s" groups, which decreased after 12 months. The bond strength was statistically similar for all materials and curing protocols after 12 months, except for Tetric PowerFill cured with the "3 s" protocol (21.22 ± 5.0 MPa), which showed the highest value. Tetric PowerFill showed the highest long-term bond strength. While "3 s" curing resulted in equal or better shear bond strength, its use can only be recommended for a material with an AFCT agent such as Tetric PowerFill.
Collapse
Affiliation(s)
- Eva Klarić
- Department of Endodontics and Restorative Dentistry, University of Zagreb School of Dental Medicine, 10000 Zagreb, Croatia; (E.K.); (M.P.); (Z.T.)
| | | | - Matej Par
- Department of Endodontics and Restorative Dentistry, University of Zagreb School of Dental Medicine, 10000 Zagreb, Croatia; (E.K.); (M.P.); (Z.T.)
| | - Zrinka Tarle
- Department of Endodontics and Restorative Dentistry, University of Zagreb School of Dental Medicine, 10000 Zagreb, Croatia; (E.K.); (M.P.); (Z.T.)
| | - Danijela Marovic
- Department of Endodontics and Restorative Dentistry, University of Zagreb School of Dental Medicine, 10000 Zagreb, Croatia; (E.K.); (M.P.); (Z.T.)
| |
Collapse
|
5
|
Thanoon H, Price RB, Watts DC. Thermography and conversion of fast-cure composite photocured with quad-wave and laser curing lights compared to a conventional curing light. Dent Mater 2024; 40:546-556. [PMID: 38326211 DOI: 10.1016/j.dental.2024.01.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2023] [Revised: 01/24/2024] [Accepted: 01/25/2024] [Indexed: 02/09/2024]
Abstract
OBJECTIVES This study investigated effects of the different emittance-mode protocols from three light curing units (LCUs): (i) a Laser (Monet); (ii) a quad-wave (PinkWave); (iii) a conventional LED (Elipar S10) on the temperature rise (ΔT) and degree of conversion (DC) when photo-curing fast or conventional bulk-fill resin-based composites (RBC). The aim was to correlate ΔT and DC, and the radiant exposure delivered to RBC specimens. METHODS A 3D-printed resin mold of 4 mm depth was filled with two bulk-fill RBCs: Tetric PowerFill® (fast photo-polymerised composite) (TPF) or Tetric EvoCeram® Bulk-Fill (EVO). Three LCUs were used: (i) Monet laser for 1 s and 3 s (MONET-1 s, MONET-3 s); (ii) PinkWave quad-wave used for 3 s in Boost mode (PW-3 s) and for 20 s in standard mode (PW-20 s); (iii) Elipar S10 for 5 s (S10-5 s) and for 20 s in standard mode (S10-20 s). 2-dimensional temperature maps were obtained before, during and for 60 s after the LCU had turned off using a thermal imaging camera. Thermal changes were analysed at five depths: (0, 1, 2, 3, and 4 mm from the top surface of the RBC). The maximum temperature rise (Tmax) and the mean temperature rise (ΔT) were determined. Cylindrical-shaped specimens were prepared from each material using a stainless-steel split mold (4 × 4 mm) and light-cured with the same protocols. The DC was measured for 120 s and at 1 h after LCU had turned off using Fourier Transform Infrared Spectroscopy (FTIR). Data were analysed using Three-way ANOVA, One-way ANOVA, independent t-tests, and Tukey post-hoc tests (p < 0.05). RESULTS Radiant exposures delivered by the various irradiation protocols were between 4.5-30.3 J/cm2. Short exposure times from MONET-1 s and PW-3 s delivered the lowest radiant exposures (4.5 and 5.2 J/cm2, respectively) and produced the lowest ΔT and DC. The longer exposure times in the standard modes of PW-20 s, S10-20 s, and MONET-3 s produced the highest Tmax, ΔT, and DC for both composites. The ΔT range among composites at different depths varied significantly (31.7-49.9 °C). DC of TPF ranged between 30-65% and in EVO between 15.3-56%. TPF had higher Tmax, ΔT for all depths and DC compared to EVO, across the LCU protocols (p < 0.05), except for PW-20 s and MONET-3 s. The coronal part of the restorations (1-2 mm) had the highest ΔT. There was a positive correlation between ΔT and DC at 4-mm depth after 120 s SIGNIFICANCE: Longer, or standard, exposure times of the LCUs delivered greater radiant exposures and had higher DC and ΔT compared to shorter or high-irradiance protocols. The fast photo-polymerised RBC had comparatively superior thermal and conversion outcomes when it received a high irradiance for a short time (1-5 s) compared to the conventional Bulk-Fill RBC.
Collapse
Affiliation(s)
- Halah Thanoon
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK; Department of Restorative Dentistry, College of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia.
| | - Richard B Price
- Department of Dental Clinical Sciences, Dalhousie University, Halifax, Nova Scotia, Canada
| | - David C Watts
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK; Photon Science Institute, University of Manchester, Manchester, UK.
| |
Collapse
|
6
|
de Deus RA, Oliveira L, Braga S, Ribeiro M, Price RB, Núñez A, Loguercio AD, Soares CJ. Effect of Radiant Exposure on the Physical and Mechanical Properties of 10 Flowable and High-viscosity Bulk-fill Resin Composites. Oper Dent 2024; 49:136-156. [PMID: 38349819 DOI: 10.2341/23-025-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/27/2023] [Indexed: 02/15/2024]
Abstract
OBJECTIVES To evaluate the effect of the different radiant exposures from a multipeak light curing unit on the physical and mechanical properties of flowable and high-viscosity bulk-fill resin-based composites (RBC). METHODS Five flowable bulk-fill RBCs (Tetric N-Flow Bulk-fill, Ivoclar Vivadent; Filtek Bulk Fill Flow, 3M Oral Care; Opus Bulk Fill Flow APS, FGM; Admira Fusion x-base, Voco and; and SDR Plus Bulk Fill Flowable, Dentsply Sirona) and five high-viscosity bulk-fill RBCs (Tetric N-Ceram Bulk-fill, Ivoclar Vivadent; Filtek One Bulk Fill, 3M Oral Care; Opus Bulk Fill APS, FGM; Admira Fusion x-tra, Voco; and SonicFill 2, Kerr) were photo-cured using a VALO Cordless light (Ultradent) for 10, 20, and 40 seconds at an irradiance of 1200, 800, or 400 mW/cm2, resulting in the delivery of 4, 8, 12, 16, 24, 32, or 48 J/cm2. Post-gel shrinkage (Shr) was calculated using strain-gauge test. The degree of conversion (DC, %) was calculated using FTIR. Knoop hardness (KH, N/mm2) and elastic modulus (E, MPa) were measured at the top and bottom surfaces. Logarithmic regressions between the radiant exposures and mechanical properties were calculated. Radiodensity was calculated using digital radiographs. Data of Shr and radiodensity were analyzed using two-way analysis of variance (ANOVA), and the DC, KH, and E data were analyzed with two-way ANOVA using split-plot repeated measurement tests followed by the Tukey test (a = 0.05). RESULTS Delivering higher radiant exposures produced higher Shr values (p<0.001) and higher DC values (R2=0.808-0.922; R2=0.648-0.914, p<0.001), KH (R2=0.707-0.952; R2=0.738-0.919; p<0.001), and E (R2=0.501-0.925; R2=0.823-0.919; p<0.001) values for the flowable and high-viscosity RBCs respectively. Lower KH, E and Shr were observed for the flowable bulk-fill RBCs. All bulk-fill RBCs had a radiopacity level greater than the 4-mm thick aluminum step wedge. The radiant exposure did not affect the radiopacity. CONCLUSION The Shr, DC, KH, and E values were highly correlated to the radiant exposure delivered to the RBCs. The combination of the higher irradiance for longer exposure time that resulted in radiant exposure between 24 J/cm2 to 48 J/cm2 produced better results than delivering 400 mW/cm2 for 40 s (16 J/cm2), and 800 mW/cm2 for 20 seconds (16 J/cm2) or 1200 mW/cm2 for 10 seconds (12 J/cm2). All the bulk-fill RBCs were sufficiently radiopaque compared to 4 mm of aluminum.
Collapse
Affiliation(s)
- R A de Deus
- Raissa Albuquerque de Deus, DDS, MSc, Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil
| | - Lrs Oliveira
- Lais Rani Sales Oliveira, DDS, MSc, PhD, Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil
| | - Ssl Braga
- Stella Sueli Lourenço Braga, DDS, MSc, PhD, Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil
| | - Mth Ribeiro
- Maria Tereza Hordones Ribeiro, DDS, MSc, PhD student, Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil
| | - R B Price
- Richard Bengt Price, DDS, MSc, PhD, Department of Dental Clinical Sciences, Dalhousie University, Halifax, Nova Scotia, Canada
| | - A Núñez
- Alejandra Núñez, DDS, MSc, PhD student, Universidade Estadual de Ponta Grossa, Ponta Grossa, PR, Brazil
| | - A D Loguercio
- Alessandro Dourado Loguercio, DDS, MSc, PhD, School of Dentistry, Universidade Estadual de Ponta Grossa, Ponta Grossa, PR, Brazil
| | - C J Soares
- *Carlos José Soares, DDS, MS, PhD, Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil
| |
Collapse
|
7
|
Algamaiah H, Yang J, Alayed A, Alshabib A, Alshehri A, Watts DC. Temperature rise in photopolymerized adhesively-bonded resin composite: A thermography study. Dent Mater 2024; 40:458-465. [PMID: 38129192 DOI: 10.1016/j.dental.2023.12.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2023] [Revised: 12/10/2023] [Accepted: 12/10/2023] [Indexed: 12/23/2023]
Abstract
OBJECTIVES To assess visually and quantitatively the contributions of the adhesive layer photopolymerization and the subsequent resin composite increment to spatio-temporal maps of temperature at five different cavity locations, subjected to two irradiance curing protocols: standard and ultra-high. METHODS Caries-free molars were used to obtain 40, 2 mm thick dentin slices, randomly assigned to groups (n = 5). These slices were incorporated within 3D-printed model cavites, 4 mm deep, restored with Adhese® Universal bonding agent and 2 mm thick Tetric® Powerfill resin composite, and photocured sequentially, as follows: G1: control-empty cavity; G2: adhesive layer; G3 composite layer with no adhesive; and G4 composite layer with adhesive. The main four groups were subdivided based on two curing protocols, exposed either to standard 10 s (1.2 W/cm2) or Ultra high 3 s (3 W/cm2) irradiance modes using a Bluephase PowerCure LCU. Temperature maps were obtained, via a thermal imaging camera, and numerically analyzed at 5 locations. The data were analyzed using two-way ANOVA followed by multiple one-way ANOVA, independent t-tests and Tukey post-hoc tests (α = 0.05). Tmax, ΔT, Tint (integrated area under the curve) and time-to-reach-maximum-temperature were evaluated. RESULTS Two-way ANOVA showed that there was no significant interaction between light-curing time and location on the measured parameters (p > 0.05), except for the time-to-reach-maximum-temperature (p < 0.05). Curing the adhesive layer alone with the 10 s protocol resulted in a significantly increased pulpal roof temperature compared to 3 s cure (p < 0.05). Independent T-tests between G3 and G4, between 3 s and 10 s, confirmed that the adhesive agent caused no significant increases (p > 0.05) on the measured parameters. The ultra-high light-curing protocol significantly increased ΔT in composite compared to 10 s curing (p < 0.05). SIGNIFICANCE When the adhesive layer was photocured alone in a cavity, with a 2 mm thick dentin floor, the exothermal release of energy resulted in higher temperatures with a 10 s curing protocol, compared to a 3 s high irradiance. But when subsequently photocuring a 2 mm layer of composite, the resultant temperatures generated at pulpal roof location from the two curing protocols were similar and therefore there was no increased hazard to the dental pulp from the immediately prior adhesive photopolymerization, cured via the ultra-high irradiation protocol.
Collapse
Affiliation(s)
- Hamad Algamaiah
- Department of Restorative Dental Science, College of Dentistry, King Saud University, P.O. Box 60169, Riyadh 11545, Saudi Arabia.
| | - Jiawei Yang
- Department of prosthodontics, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, Shanghai, China; National Clinical Research Center for Oral Diseases, College of Stomatology, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Abdulaziz Alayed
- Department of Restorative Dental Science, College of Dentistry, King Saud University, P.O. Box 60169, Riyadh 11545, Saudi Arabia; Biomaterials Science, Division of Dentistry, School of Medical Sciences, University of Manchester, UK
| | - Abdulrahman Alshabib
- Department of Restorative Dental Science, College of Dentistry, King Saud University, P.O. Box 60169, Riyadh 11545, Saudi Arabia
| | - Abdullah Alshehri
- Department of Conservative Dental Sciences, College of Dentistry, Prince Sattam Bin Abdulaziz University, Alkharj 11942, Saudi Arabia
| | - David C Watts
- Biomaterials Science, Division of Dentistry, School of Medical Sciences, University of Manchester, UK; Photon Science Institute, University of Manchester, UK.
| |
Collapse
|
8
|
Tsertsidou V, Mourouzis P, Dionysopoulos D, Pandoleon P, Tolidis K. Fracture Resistance of Class II MOD Cavities Restored by Direct and Indirect Techniques and Different Materials Combination. Polymers (Basel) 2023; 15:3413. [PMID: 37631470 PMCID: PMC10458958 DOI: 10.3390/polym15163413] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2023] [Revised: 08/04/2023] [Accepted: 08/14/2023] [Indexed: 08/27/2023] Open
Abstract
This study aimed to evaluate the fracture resistance of class II MOD cavities restored using different techniques and materials. Sixty extracted maxillary molars were selected and standardized class II MOD cavities were prepared using a custom-made paralleling device. The specimens were divided into four groups based on the restoration technique used: Group 1 (direct resin composite), Group 2 (short-fiber-reinforced composite resin), Group 3 (composite polyethylene fiber reinforcement), and Group 4 (CAD/CAM resin inlays). Fracture resistance was assessed for each group after thermocycling aging for 10,000 cycles. The mode of fracture was assigned to five types using Burke's classification. To compare the fracture force among the tested materials, a paired sample t-test was performed. The significance level for each test was set at p < 0.05. Significant differences in fracture resistance were observed among the different restoration techniques. CAD/CAM inlays (2166 ± 615 N), short-fiber-reinforced composite resin (2471 ± 761 N), and composite polyethylene fiber reinforcement (1923 ± 492 N) showed superior fracture resistance compared to the group restored with direct resin composite (1242 ± 436 N). The conventional resin composite group exhibited the lowest mean fracture resistance. The choice of restoration material plays a critical role in the clinical survival of large MOD cavities. CAD/CAM inlays and fiber-reinforced composites offer improved fracture resistance, which is essential for long-term success in extensive restorations.
Collapse
Affiliation(s)
- Vasiliki Tsertsidou
- Department of Dental Tissues Pathology and Therapeutics, Division of Operative Dentistry, Faculty of Dentistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece; (V.T.); (D.D.); (K.T.)
| | - Petros Mourouzis
- Department of Dental Tissues Pathology and Therapeutics, Division of Operative Dentistry, Faculty of Dentistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece; (V.T.); (D.D.); (K.T.)
| | - Dimitrios Dionysopoulos
- Department of Dental Tissues Pathology and Therapeutics, Division of Operative Dentistry, Faculty of Dentistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece; (V.T.); (D.D.); (K.T.)
| | - Panagiotis Pandoleon
- Department of Prosthodontics, Faculty of Dentistry, School of Health Sciences, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece;
| | - Kosmas Tolidis
- Department of Dental Tissues Pathology and Therapeutics, Division of Operative Dentistry, Faculty of Dentistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece; (V.T.); (D.D.); (K.T.)
| |
Collapse
|
9
|
Maucoski C, Price RB, Arrais CAG. Temperature changes and hardness of resin-based composites light-cured with laser diode or light-emitting diode curing lights. Odontology 2023; 111:387-400. [PMID: 36184680 DOI: 10.1007/s10266-022-00745-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Accepted: 09/13/2022] [Indexed: 11/25/2022]
Abstract
The temperature and Vickers Hardness (VH) at the top and bottom surfaces of three resin-based composites (RBCs) were measured when light-cured using five light-curing units (LCUs). The spectrum, power, and energy delivered to the top of the RBCs and transmitted through the RBCs were measured. Starting at 32℃, the temperature rise produced by the Monet Laser (ML-1 s and 3 s), Valo Grand (VG-3 s and 10 s), DeepCure (DC-10 s), PowerCure, (PC-3 s and 10 s) and PinkWave (PW-10 s) were measured at the bottom of specimens 2 mm deep × 6 mm wide made of Filtek Universal A2, Tetric Evoceram A2 and an experimental RBC codenamed Transcend UB. The VH values measured at the top and bottom of these RBCs were analyzed using ANOVA and Scheffe's post hoc test (p < 0.05) to determine the effects of the LCUs on the RBCs. The transmitted power from the ML was reduced by 77.4% through 2 mm of Filtek Universal, whereas light from PW decreased by only 36.8% through Transcend. The highest temperature increases from the LCU combined with the exothermic reaction occurred for Transcend, and overall, no significant differences were detected between Filtek Universal and Tetric Evoceram (p = 0.9756). Transcend achieved the highest VH values at the top and bottom surfaces. The PinkWave used for 10 s produced the largest temperature increase (20.2℃) in Transcend. The Monet used for 1 s produced the smallest increase (7.8℃) and the lowest bottom:top VH ratios.
Collapse
Affiliation(s)
- Cristiane Maucoski
- Department of Dental Clinical Sciences, Dalhousie University, Halifax, NS, B3H 4R2, Canada.
- Department of Restorative Dentistry, The State University of Ponta Grossa, 4748 General Carlos Cavalcanti Av., Ponta Grossa, Parana, 84051-130, Brazil.
| | - Richard Bengt Price
- Department of Dental Clinical Sciences, Dalhousie University, Halifax, NS, B3H 4R2, Canada
| | - Cesar Augusto Galvão Arrais
- Department of Restorative Dentistry, The State University of Ponta Grossa, 4748 General Carlos Cavalcanti Av., Ponta Grossa, Parana, 84051-130, Brazil
| |
Collapse
|
10
|
Lempel E, Szebeni D, Őri Z, Kiss T, Szalma J, Lovász BV, Kunsági-Máté S, Böddi K. The effect of high-irradiance rapid polymerization on degree of conversion, monomer elution, polymerization shrinkage and porosity of bulk-fill resin composites. Dent Mater 2023; 39:442-453. [PMID: 36918332 DOI: 10.1016/j.dental.2023.03.016] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Revised: 02/17/2023] [Accepted: 03/03/2023] [Indexed: 03/13/2023]
Abstract
OBJECTIVE The purpose was to compare the degree of conversion (DC), monomer elution (ME), polymerization shrinkage (PS) and porosity of two addition-fragmentation chain transfer (AFCT) modified resin-based composites (RBC) light-cured with rapid- (RP), turbo- (TP) or conventional polymerization (CP) settings. METHODS Cylindrical samples (6-mm wide, 4-mm thick) were prepared from Tetric PowerFill (TPF) and Filtek One Bulk (FOB). Four groups were established according to the polymerization settings: 3s-RP, 5s-TP, 10s-CP and 20s-CP. Samples in 1 mm thickness with 20s-CP settings served as controls. The DC at the top and bottom surfaces was measured with micro-Raman spectroscopy. ME was detected with high-performance liquid chromatography. PS and porosity were analyzed by micro-computed tomography. ANOVA and Tukey's post-hoc test, multivariate analysis and partial eta-squared statistics were used to analyze the data (p < 0.05). RESULTS FOB showed higher DC values (61.5-77.5 %) at the top compared to TPF (43.5-67.8 %). At the bottom TPF samples achieved higher DCs (39.9-58.5 %) than FOB (18.21-66.18 %). Extending the curing time increased DC (except the top of FOB) and decreased ME. BisGMA release was the highest among the detected monomers from both RBCs. The amount was three-fold more from TPF. The factor Material and Exposure significantly influenced DC and ME. PS (1.8-2.5 %) did not differ among the groups and RBCs except for the lowest value of TPF cured with the 3s_RP setting (p = 0.03). FOB showed 4.5-fold lower porosity (p < 0.001). Significantly higher pore volume was detected after polymerization in 3s_RP (p < 0.001). SIGNIFICANCE High-irradiance rapid 3-s curing of AFCT modified RBCs resulted in inferior results for some important material properties. A longer exposure time is recommended in a clinical situation.
Collapse
Affiliation(s)
- Edina Lempel
- Department of Restorative Dentistry and Periodontology, University of Pécs Medical School, Tüzér Street 1, Pécs 7623, Hungary.
| | - Donát Szebeni
- Department of Restorative Dentistry and Periodontology, University of Pécs Medical School, Tüzér Street 1, Pécs 7623, Hungary
| | - Zsuzsanna Őri
- János Szentágothai Research Center, Ifjúság Street 12, Pécs 7624, Hungary; Department of General and Physical Chemistry, University of Pécs, Ifjúság Street 6, Pécs 7624, Hungary
| | - Tamás Kiss
- János Szentágothai Research Center, Ifjúság Street 12, Pécs 7624, Hungary
| | - József Szalma
- Department of Oral and Maxillofacial Surgery, University of Pécs Medical School, Tüzér Street 1, Pécs 7623, Hungary
| | - Bálint Viktor Lovász
- Department of Oral and Maxillofacial Surgery, University of Pécs Medical School, Tüzér Street 1, Pécs 7623, Hungary
| | - Sándor Kunsági-Máté
- János Szentágothai Research Center, Ifjúság Street 12, Pécs 7624, Hungary; Department of Organic and Medicinal Chemistry, University of Pécs, Faculty of Pharmacy, Honvéd Street 1, Pécs 7624, Hungary
| | - Katalin Böddi
- Department of Biochemistry and Medical Chemistry, University of Pécs Medical School, Szigeti Street 12, Pécs 7624, Hungary
| |
Collapse
|
11
|
Watts DC. Light-curing dental resin-based composites: How it works and how you can make it work. FRONTIERS IN DENTAL MEDICINE 2023. [DOI: 10.3389/fdmed.2023.1108316] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/09/2023] Open
Abstract
AimClinicians may become quite familiar with the rapid transformation of composite pastes to rigid solids, as a routine phenomenon in operative dentistry. But they may still lack scientific understanding of how and why this happens. Efforts to learn scientifically about the interaction between light beams and resin-composites can significantly promote effective clinical placement of restorations. Neglect of such study can result in practical procedures of light-curing that are inadequate or even seriously defective.MethodThis review addresses the underlying science and technology to elucidate how light curing works, for dental resin-based composites, including—but not limited to—bulk fill types. This involves questions concerning: (a) the particle-wave understanding of light; (b) how photons can penetrate sufficiently deeply into bulk fill composites; (c) the necessary technology of LED light-curing units (LCUs); (d) the criteria for absorption of photons by photo initiators to initiate free-radical addition polymerisation.ConclusionsThe implications for clinical practice are surveyed. These include design variables and selection criteria for LED-LCUs and guidelines on their use. This is to guide practitioners towards safe and effective light-curing procedures so that they can achieve optimal result for their patients.
Collapse
|
12
|
Maucoski C, Price RB, Rocha MG, Roulet JF, Sullivan B. Ability of short exposures from laser and quad-wave curing lights to photo-cure bulk-fill resin-based composites. Dent Mater 2023; 39:275-292. [PMID: 36868892 DOI: 10.1016/j.dental.2023.01.007] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Revised: 01/10/2023] [Accepted: 01/25/2023] [Indexed: 03/05/2023]
Abstract
OBJECTIVE This study investigated the ability of a laser, and a 'quad-wave' LCU, to photo-cure paste and flowable bulk-fill resin-based composites (RBCs). METHODS Five LCUs and nine exposure conditions were used. The laser LCU (Monet) used for 1 s and 3 s, the quad-wave LCU (PinkWave) used for 3 s in the Boost and 20 s in the Standard modes, the the multi-peak LCU (Valo X) used for 5 s in the Xtra and 20 s in the Standard modes, were compared to the polywave PowerCure used in the 3 s mode and for 20 s in the Standard mode, and to the mono-peak SmartLite Pro used for 20 s. Two paste consistency bulk-fill RBCs: Filtek One Bulk Fill Shade A2 (3 M), Tetric PowerFill Shade IVA (Ivoclar Vivadent), and two flowable RBCs: Filtek Bulk Fill Flowable Shade A2 (3 M), Tetric PowerFlow Shade IVA (Ivoclar Vivadent) were photo-cured in 4-mm deep x 4-mm diameter metal molds. The light received by these specimens was measured using a spectrometer (Flame-T, Ocean Insight), and the radiant exposure delivered to the top surface of the RBCs was mapped. The immediate degree of conversion (DC) at the bottom, and the 24-hour Vickers Hardness (VH) at the top and bottom of the RBCs were measured and compared. RESULTS The irradiance received by the 4-mm diameter specimens ranged from 1035 mW/cm2 (SmartLite Pro) to 5303 mW/cm2 (Monet). The radiant exposures between 350 and 500 nm delivered to the top surface of the RBCs ranged from 5.3 J/cm2 (Monet in 1 s) to 26.4 J/cm2 (Valo X), although the PinkWave delivered 32.1 J/cm2 in 20 s 350 to 900 nm. All four RBCs achieved their maximum DC and VH values at the bottom when photo-cured for 20 s. The Monet used for 1 s and the PinkWave used for 3 s on the Boost setting delivered the lowest radiant exposures between 420 and 500 nm (5.3 J/cm2 and 3.5 J/cm2 respectively), and they produced the lowest DC and VH values. CONCLUSIONS Despite delivering a high irradiance, the short 1 or 3-s exposures delivered less energy to the RBC than 20-s exposures from LCUs that deliver> 1000 mW/cm2. There was an excellent linear correlation (r > 0.98) between the DC and the VH at the bottom. There was a logarithmic relationship between the DC and the radiant exposure (Pearson's r = 0.87-97) and between the VH and the radiant exposure (Pearson's r = 0.92-0.96) delivered in the 420-500 nm range.
Collapse
Affiliation(s)
- Cristiane Maucoski
- Department of Restorative Dentistry, State University of Ponta Grossa, Ponta Grossa, Parana, Brazil; Department of Dental Clinical Sciences, Dalhousie University, Faculty of Dentistry, Halifax, Nova Scotia, Canada
| | - Richard Bengt Price
- Department of Dental Clinical Sciences, Dalhousie University, Faculty of Dentistry, Halifax, Nova Scotia, Canada.
| | - Mateus Garcia Rocha
- Department of Restorative Dental Science, Center of Dental Biomaterials College of Dentistry, University of Florida, Gainesville, FL, USA
| | - Jean-François Roulet
- Department of Restorative Dental Science, Center of Dental Biomaterials College of Dentistry, University of Florida, Gainesville, FL, USA
| | - Braden Sullivan
- Department of Restorative Dentistry, State University of Ponta Grossa, Ponta Grossa, Parana, Brazil
| |
Collapse
|
13
|
Steffen T, Par M, Attin T, Tauböck TT. Effect of Fast High-Irradiance Photo-Polymerization of Resin Composites on the Dentin Bond Strength. MATERIALS (BASEL, SWITZERLAND) 2022; 15:7467. [PMID: 36363058 PMCID: PMC9655088 DOI: 10.3390/ma15217467] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Revised: 10/20/2022] [Accepted: 10/21/2022] [Indexed: 06/16/2023]
Abstract
This study investigated the influence of conventional (10 s at 1160 mW/cm2) and fast high-irradiance (3 s at 2850 mW/cm2) light curing on the micro-tensile bond strength (μTBS) of bulk-fill resin composites bonded to human dentin. Sixty-four extracted human molars were ground to dentin and randomly assigned into eight groups (n = 8 per group). After application of a three-step adhesive system (Optibond FL), four different bulk-fill composites (two sculptable and two flowable composites) were placed. Of these, one sculptable (Tetric PowerFill) and one flowable (Tetric PowerFlow) composite were specifically developed for fast high-irradiance light curing. Each composite was polymerized with the conventional or the fast high-irradiance light-curing protocol. The specimens were cut into dentin-composite sticks, μTBS was determined and failure modes were analyzed. Statistical analysis was performed using t-test for independent observations and one-way ANOVA. A statistical difference between the curing protocols was only found for Tetric PowerFlow, where the conventional protocol (23.8 ± 4.2 MPa) led to significantly higher values than the fast high-irradiance light-curing protocol (18.7 ± 3.7 MPa). All other composite materials showed statistically similar values for both polymerization protocols. In conclusion, the use of fast high-irradiation light curing has no negative influence on the μTBS of the investigated high-viscosity bulk-fill composites. However, it may reduce the dentin bond strength of flowable bulk-fill composite.
Collapse
Affiliation(s)
- Tobias Steffen
- Clinic of Conservative and Preventive Dentistry, Center for Dental Medicine, University of Zurich, 8032 Zurich, Switzerland
| | - Matej Par
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000 Zagreb, Croatia
| | - Thomas Attin
- Clinic of Conservative and Preventive Dentistry, Center for Dental Medicine, University of Zurich, 8032 Zurich, Switzerland
| | - Tobias T. Tauböck
- Clinic of Conservative and Preventive Dentistry, Center for Dental Medicine, University of Zurich, 8032 Zurich, Switzerland
| |
Collapse
|
14
|
Polymerization Kinetics and Development of Polymerization Shrinkage Stress in Rapid High-Intensity Light-Curing. Polymers (Basel) 2022; 14:polym14163296. [PMID: 36015552 PMCID: PMC9415313 DOI: 10.3390/polym14163296] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Revised: 08/08/2022] [Accepted: 08/11/2022] [Indexed: 11/17/2022] Open
Abstract
This study investigated polymerization kinetics, linear shrinkage, and shrinkage stress development for six contemporary composite materials of different viscosities cured using radiant exitances of 1100–2850 mW/cm2. Real-time measurements of degree of conversion, linear shrinkage, and shrinkage stress were performed over 5 min using Fourier-transform infrared spectrometry, a custom-made linometer, and a custom-made stress analyzer, respectively. For most tested variables, the factor “material” had a higher effect size than the factor “curing protocol”. Maximum polymerization rate and maximum shrinkage stress rate were the most affected by changes in curing conditions. In contrast, no significant effects of curing conditions were identified within each material for shrinkage stress values measured at the end of the 5 min observation period. Linear shrinkage and shrinkage stress values measured after 5 min were closely correlated (R = 0.905–0.982). The analysis of polymerization kinetics suggested that the two composites specifically designed for rapid light-curing responded to higher radiant exitances differently than other composites. Polymerization kinetics and shrinkage stress behavior of contemporary restorative composite materials of different viscosities were overall more affected by material type than differences in curing conditions. Subtle differences in polymerization kinetics behavior shown by the two composites specifically designed for rapid high-intensity light-curing did not translate into significant differences in the development of polymerization shrinkage stress.
Collapse
|
15
|
Rocha MG, Oliveira DCRSD, de Menezes LR, Roulet JF, Sinhoreti MAC, Correr AB. The use of an elastomeric methacrylate monomer (Exothane 24) to reduce the polymerization shrinkage stress and improve the two-body wear resistance of bulk fill composites. Dent Mater 2021; 38:e43-e57. [PMID: 34953625 DOI: 10.1016/j.dental.2021.12.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2021] [Revised: 12/07/2021] [Accepted: 12/08/2021] [Indexed: 11/03/2022]
Abstract
OBJECTIVES Characterize the chemical structure of an elastomeric monomer (Exothane 24) and evaluate the degree of conversion (DC), polymerization shrinkage stress (PSS), rate of polymerization (Rp), flexural strength (FStrenght), flexural modulus (FModulus), Vickers hardness (VHardness) and two-body wear resistance of dental bulk fill composites (BFCs) containing Exothane 24. METHODS The Exothane 24 was characterized using mass spectroscopy, elemental analysis, 13C- and 1H NMR. BFCs were formulated containing Exothane 24 (E10, E25, and E50). Similar BFCs containing regular UDMA (U10, U25, and U50), commercial conventional, and BFCs were used as control groups. ATR-FTIR spectroscopy was used to measure DC and the Rp of the composites. The PSS was measured using the universal testing machine method. Specimen bars were used to assess the FStrenght, FModulus, and VHardness. RBCs were submitted to a two-body wear test using a chewing simulator machine; the rate and volumetric wear loss were evaluated using an optical scanner. Data were analyzed statistically with α = 0.05 and β = 0.2. RESULTS Exothane 24 is a urethane isophorone tetramethyl methacrylate monomer with polymerization stress-relieving properties. No differences were found in the DC up to 4 mm in depth for E25. All BFCs had similar FStrenght, except for E50. E25 had the lowest volumetric wear loss and wear rate. E25 had approximately 30% lower PSS and slower Rp than commercial BFCs with similar wear resistance to conventional commercial composites. SIGNIFICANCE The Exothane 24 reduced the PSS and increased the wear resistance of BFCs; however, the formulation is important to optimize the properties of the BFCs.
Collapse
Affiliation(s)
- Mateus Garcia Rocha
- Center for Dental Biomaterials, Department of Restorative Dental Sciences, College of Dentistry, University of Florida, Gainesville, FL, USA.
| | | | - Livia Rodrigues de Menezes
- Institute of Macromolecules Professor Eloisa Mano, Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil
| | - Jean-François Roulet
- Center for Dental Biomaterials, Department of Restorative Dental Sciences, College of Dentistry, University of Florida, Gainesville, FL, USA
| | | | | |
Collapse
|
16
|
Sullivan B, Kalliecharan D, Kostylev I, Earle G, Stansbury JW, Price RB, Labrie D. Photo-polymerization kinetics of a dental resin at a high temporal resolution. J Mech Behav Biomed Mater 2021; 124:104884. [PMID: 34638087 DOI: 10.1016/j.jmbbm.2021.104884] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2021] [Revised: 09/28/2021] [Accepted: 10/04/2021] [Indexed: 10/20/2022]
Abstract
OBJECTIVES This study: 1) aims to measure with high temporal resolution the intrinsic rate of the degree of conversion (DC) of a dental resin-based composite (RBC) photo-cured at two irradiances; 2) aims to determine the transition time at which the DC rate is maximum; 3) used two different irradiances to measure the shift in transition time; 4) aims to compare transition times measured using DC and shrinkage strain. METHODS Samples (n = 20) 1 mm thick by 10 mm diameter of Filtek One bulk-fill restorative A2 shade (3M Oral Care) were photocured for 20 s with a single emission peak (wavelength centered at 455 nm) light-emitting-diode-based light-curing unit at irradiance levels of 890 mW/cm2 and 209 mW/cm2, and initial sample temperature of T = 23 °C. The DC was measured in real-time using Attenuated Total Reflection (ATR) FTIR spectroscopy with a sampling rate of 13 DC data points per second. The data were analyzed within a phenomenological autocatalytic model. In addition, the axial shrinkage strain was measured using 3 samples of the RBC with the same outer dimensions and under similar experimental conditions using the bonded disk method and an interferometric technique. RESULTS For the 890 mW/cm2 and 209 mW/cm2 irradiance levels, the DC with time was found to agree with the model enabling the determination of transition times of 0.66 ± 0.05 s and 2.3 ± 0.2 s, and the DC at these times of 5.5 ± 0.2% and 6.4 ± 0.2%. The maximum linear strain rate at 0.76 ± 0.01 s and 1.98 ± 0.02 s for the 890 mW/cm2 and 209 mW/cm2 irradiance levels, respectively, are within two standard deviations of the corresponding transition times. SIGNIFICANCE At an irradiance level much greater than 1000 mW/cm2, the photo-polymerization kinetics of a dental RBC may be too fast to be measured accurately using ATR-FTIR spectroscopy. A viable alternative to monitor the kinetics is through the measurements of the axial shrinkage strain employing the bonded disk method and an interferometric technique.
Collapse
Affiliation(s)
- Braden Sullivan
- Department of Dental Clinical Sciences, Dalhousie University, Halifax, Nova Scotia, B3H 4R2, Canada
| | - David Kalliecharan
- Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia, B3H 4R2, Canada
| | - Ivan Kostylev
- Quantum Dynamics Unit, Okinawa Institute of Science and Technology, Tancha 1919-1, Okinawa, 904-0495, Japan
| | - Guy Earle
- IObIO Inc., 1676 Edward Street, Halifax, Nova Scotia, B3H 3J3, Canada
| | - Jeffrey W Stansbury
- Department of Craniofacial Biology, School of Dental Medicine, University of Colorado, Anschutz Medical Campus, Aurora, CO, 80045, United States; Department of Chemical and Biological Engineering, University of Colorado, Boulder, CO, 80309-0596, United States
| | - Richard B Price
- Department of Dental Clinical Sciences, Dalhousie University, Halifax, Nova Scotia, B3H 4R2, Canada
| | - Daniel Labrie
- Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia, B3H 4R2, Canada.
| |
Collapse
|
17
|
Algamaiah H, Watts DC. Post-irradiation surface viscoelastic integrity of photo-polymerized resin-based composites. Dent Mater 2021; 37:1828-1833. [PMID: 34593246 DOI: 10.1016/j.dental.2021.09.012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2021] [Revised: 09/13/2021] [Accepted: 09/13/2021] [Indexed: 11/24/2022]
Abstract
OBJECTIVE A class of ultra-rapid-cure resin-based composites (RBCs) exhibited immediate post-irradiation surface viscoelastic integrity using an indentation-creep/recovery procedure. The aim of this study was to determine whether such behavior is more generally characteristic of a wider range of RBCs. METHODS Eight representative RBCs were selected based on different clinical categories: three bulkfills (OBF, Filtek One Bulk Fill; VBF, Venus Bulkfill; EBF, Estelite Bulkfill), three conventional non-flowables (XTE, Filtek Supreme XTE; GSO, GrandioSo; HRZ, Harmonize) and conventional flowables (XTF, Filtek Supreme XTE Flow; GSF, GrandioSo Flow). Stainless steel split molds were used to fabricate cylindrical specimens (4mm (dia)×4mm). These were irradiated (1.2W/cm2) for 20s on the top surface. Post-irradiation specimens (n=3), within their molds, were centrally loaded with a flat-ended 1.5mm diameter indenter under 14MPa stress: either immediately (<2min) or after 24h delayed indentation. Stress was maintained for 2h, then - after removal - recovery measurements continued for a further 2h. Indentation depth (%) versus time was measured continuously to an accuracy of <0.1μm. Data were analyzed by One-way ANOVA and Tukey post-hoc tests (α=0.05). RESULTS Time-dependent viscoelastic indentation was observed for all RBCs. For immediate indentation, the maximum indentation range was 1.43-4.92%, versus 0.70-2.22% for 24h delayed indentation. Following 2h recovery, the residual indentation range was 0.86-3.58% after immediate indentation, reducing to 0.22-1.27% for delayed indentation. The greatest immediate indentation was shown by VBF followed by XTF and GSF. OBF, HRZ, XTE and GSO had significantly lower indentations (greater hardness). XTE showed a significantly reduced indentation maximum compared to OBF (p<0.05). Indentations delayed until 24h post-irradiation were reduced (p<0.05) for most materials. SIGNIFICANCE The indentation-creep methodology effectively characterized resin-based composites within several categories. Viscoelastic properties evaluated by the indentation-creep method confirmed that highly filled RBCs were more resistant to indentation. Indentations were reduced after 24h post-irradiation due to further matrix-network development.
Collapse
Affiliation(s)
- Hamad Algamaiah
- Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK; Department of Restorative Dental Science, College of Dentistry, King Saud University, Riyadh, Saudi Arabia.
| | - David C Watts
- Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK; Photon Science Institute, University of Manchester, Manchester, UK.
| |
Collapse
|
18
|
Ilie N, Diegelmann J. Impact of ultra-fast (3 s) light-cure on cell toxicity and viscoelastic behavior in a dental resin-based composite with RAFT-mediated polymerization. J Mech Behav Biomed Mater 2021; 124:104810. [PMID: 34500355 DOI: 10.1016/j.jmbbm.2021.104810] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Revised: 08/31/2021] [Accepted: 09/02/2021] [Indexed: 11/17/2022]
Abstract
OBJECTIVE The aim of the study was to determine the effects of ultra-fast (3 s) light-curing on the viscoelastic behaviour at clinically relevant frequencies, and cell toxicity, in a resin-based composite (RBC) with reversible addition-fragmentation-chain transfer (RAFT) mediated polymerization. METHODS Three different protocols were used to cure cylindrical samples (height = 4 mm, ϴ = 5 mm), including ultra-fast (3s) cure with high radiant emittance, 10 s and 20 s cure with moderate radiant emittance. The properties of the light curing device were evaluated in all curing protocols by spectrophotometry up to an exposure distance of 10 mm. The light transmission through the samples was determined in real-time with the same spectrophotometer. Absorbance was calculated as a function of wavelength. The quasi-static (indentation hardness/HIT, indentation modulus/EIT) and viscoelastic (storage modulus/E', loss modulus/E″, loss factor/tan δ) material behavior was determined in an instrumented indentation test with a DMA (Dynamic Mechanical Analysis) module for 10 frequencies (0.5-5 Hz) by profiling the center of the samples in 330 μm steps from top to bottom. Cellular toxicity on human gingival fibroblast (HGF-1) was assessed using a WST-1 colorimetric assay after incubation time of up to 3 months. One and multiple-way analysis of variance (ANOVA) with Tukey honestly significant difference (HSD) post-hoc tests (α = 0.05) were applied. RESULTS The irradiance transmitted through a 4 mm high sample was less than 7% of the incident irradiance, and the absorbance was similar for all curing protocols, showing a decrease with wavelength. Similar quasi-static and viscoelastic parameters were observed regardless of the curing protocol. HIT increased slightly and EIT, E', E″ and tan δ decreased with frequency. Occasionally, slightly higher confidence intervals were observed for the ultra-fast curing group, which were related to a potential accumulation of stress. The curing protocol had no effect on cell viability (p = 0.326) but the eluate age (p < 0.001, ηP2 = 0.879) did. None of the groups showed cell toxicity at any point in time with respect to the corresponding negative control. CONCLUSIONS The ultra-fast curing with high irradiance induced no cell toxicity and an equivalent viscoelastic behavior as with conventional curing protocols in a RAFT-modified RBC.
Collapse
Affiliation(s)
- Nicoleta Ilie
- Department of Conservative Dentistry and Periodontology, University Hospital, LMU, Germany.
| | - Julia Diegelmann
- Department of Conservative Dentistry and Periodontology, University Hospital, LMU, Germany
| |
Collapse
|
19
|
Yang J, Algamaiah H, Watts DC. Spatio-temporal temperature fields generated coronally with bulk-fill resin composites: A thermography study. Dent Mater 2021; 37:1237-1247. [PMID: 34144795 DOI: 10.1016/j.dental.2021.06.008] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Revised: 06/01/2021] [Accepted: 06/01/2021] [Indexed: 12/13/2022]
Abstract
OBJECTIVE This study aimed to investigate the effects of (i) a high-irradiance (3s) light-curing protocol versus (ii) two standard-irradiance (10s) protocols on 2D temperature maps during intra-dental photo-irradiation within a molar cavity restored with either Ultra-Rapid Photo-Polymerized Bulk Fill (URPBF) composites or a pre-heated thermo-viscous bulk-fill composite, compared to a standard bulk-fill resin-based-composite (RBC). The specific objectives included visual assessment of the temperature maps and quantitative assessment of several temperature/time plots at four different locations. METHODS A caries-free lower first molar cavity served as a natural tooth mold. Resin composites were placed without intermediary adhesive. Two URPBF composites (PFill; PFlow) and one pre-heated thermo-viscous bulk-fill composite (Viscalor: VC) were compared to a contemporary bulk-fill composite (One Bulk Fill: OBF). Two LED-LCU devices were used: Bluephase PowerCure (PC) and Elipar S10 (S10), with three light-irradiation protocols (PC-3s, PC-10s and S10-10s). 2D temperature maps over the entire coronal area were recorded for 120 s during and after irradiation using a thermal imaging camera. Changes at four different levels were selected from the data sets: (0, 2 and 4 mm from the cavity top and at 1 mm below the dentin cavity floor). The maximum temperature attained (Tmax), the mean temperature rise (ΔT), the time (s) to reach maximum temperature and the integrated areas (°C s) under the temperature/time (T/t) plots were identified. Data were analysed via three-way ANOVA, One-way ANOVA, independent t-tests and Tukey post-hoc tests (p < 0.05). RESULTS All RBCs showed qualitatively similar temperature-time profiles. PFlow reached Tmax in the shortest time. PC-3s (3000 mW/cm2) generated comparable ΔT to S10-10s, except with PFill, where ΔT was greater. Despite the same irradiance (1200 mW/cm2), Elipar S10 led to higher Tmax and ΔT compared to PC-10s. The highest Tmax and ΔT were observed at the 2 mm level, and the lowest were at 1 mm depth into the underlying dentin. SIGNIFICANCE Coronal 2D temperature maps showed rises largely confined within the bulk-fill RBC materials, with maxima at 2 mm rather than 4 mm depth indicating some extent of thermal insulation for the underlying dentin and pulp. RBCs polymerized via different irradiation protocols showed similar temperature changes. With the PC-3s protocol - also with pre-heated VC - minimal temperature rises at 1 mm within dentin suggest their clinical safety when sufficient remaining dentin thickness is present.
Collapse
Affiliation(s)
- Jiawei Yang
- Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK
| | - Hamad Algamaiah
- Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK; Department of Restorative Dental Science, College of Dentistry, King Saud University, Riyadh, Saudi Arabia.
| | - David C Watts
- Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK; Photon Science Institute, University of Manchester, Manchester, UK.
| |
Collapse
|