1
|
Mudhaffer S, Althagafi R, Haider J, Satterthwaite J, Silikas N. Effects of printing orientation and artificial ageing on martens hardness and indentation modulus of 3D printed restorative resin materials. Dent Mater 2024; 40:1003-1014. [PMID: 38735775 DOI: 10.1016/j.dental.2024.05.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2024] [Revised: 04/29/2024] [Accepted: 05/03/2024] [Indexed: 05/14/2024]
Abstract
BACKGROUND Three-dimensional (3D) printing is increasingly used to fabricate dental restorations due to its enhanced precision, consistency and time and cost-saving advantages. The properties of 3D-printed resin materials can be influenced by the chosen printing orientation which can impact the mechanical characteristics of the final products. PURPOSE The objective of this study was to evaluate the influence of printing orientation and artificial ageing on the Martens hardness (HM) and indentation modulus (EIT) of 3D-printed definitive and temporary dental restorative resins. METHODS Disk specimens (20 mm diameter × 2 mm height) were additively manufactured in three printing orientations (0°, 45°, 90°) using five 3D-printable resins: VarseoSmile Crownplus (VCP), Crowntec (CT), Nextdent C&B MFH (ND), Dima C&B temp (DT), and GC temp print (GC). The specimens were printed using a DLP 3D-printer (ASIGA MAX UV), while LavaTM Ultimate (LU) and Telio CAD (TC) served as milled control materials. Martens hardness (HM) and indentation modulus (EIT) were tested both before and after storage in distilled water and artificial saliva for 1, 30, and 90 days at 37 °C. RESULTS 90° printed specimens exhibited higher HM than the other orientations at certain time points, but no significant differences were observed in HM and EIT between orientations for all 3D-printed materials after 90 days of ageing in both aging media. LU milled control material exhibited the highest HM and EIT among the tested materials, while TC, the other milled control, showed similar values to the 3D printed resins. CT and VCP (definitive resins) and ND displayed higher Martens parameters compared to DT and GC (temporary resins). The hardness of the 3D-printed materials was significantly impacted by artificial ageing compared to the controls, with ND having the least hardness reduction percentage amongst all 3D-printed materials. The hardness reduction percentage in distilled water and artificial saliva was similar for all materials except for TC, where higher reduction was noted in artificial saliva. SIGNIFICANCE The used 3D printed resins cannot yet be considered viable alternatives to milled materials intended for definitive restorations but are preferable for use as temporary restorations.
Collapse
Affiliation(s)
- Shaymaa Mudhaffer
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK; Substitutive Dental Sciences, Faculty of Dentistry, Taibah University, Madinah, Saudi Arabia.
| | - Rana Althagafi
- Substitutive Dental Sciences, Faculty of Dentistry, Taibah University, Madinah, Saudi Arabia
| | - Julfikar Haider
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK; Department of Engineering, Manchester Metropolitan University, Manchester, UK
| | - Julian Satterthwaite
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK
| | - Nick Silikas
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK.
| |
Collapse
|
2
|
Alamoush RA, Yang J, Alhotan A, Haider J, Matinlinna JP, Elraggal A. The effect of in-office bleaching agents on the Vickers hardness and surface topography of polished and unpolished CAD/CAM composite materials. Sci Rep 2023; 13:15341. [PMID: 37714943 PMCID: PMC10504265 DOI: 10.1038/s41598-023-42415-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2023] [Accepted: 09/10/2023] [Indexed: 09/17/2023] Open
Abstract
In-office bleaching, using hydrogen peroxide, is effective to remove dental enamel stains. However, bleaching agents can deteriorate surface properties of CAD-CAM materials. This in vitro study aimed to investigate the effect of in-office bleaching agents on Vickers hardness and surface topography of polished and unpolished dental CAD-CAM composite materials (Grandio blocs, Lava Ultimate, BRILLIANT Crios, Cerasmart), and a polymer-infiltrated ceramic network block (Vita Enamic). The specimens were randomly divided into two groups: unpolished or polished. The micro-hardness and surface topography of each group were measured before bleaching, after a 60 min bleaching period, and 24-h and one-month post-bleaching. In-office bleaching significantly influenced the Vickers hardness of both the polished and unpolished CAD/CAM composite blocks, with Vita Enamic exhibiting the least hardness stability among all groups. Furthermore, in-office bleaching significantly influenced the surface roughness of unpolished CAD/CAM composite blocks. There was a significant difference in hardness reduction between the polished and unpolished specimens for most of the investigated materials at different time points. The bleaching did not influence the surface roughness of the investigated polished group, except for Vita Enamic and Lava Ultimate. However, it did influence the surface roughness of the investigated materials in the unpolished group.
Collapse
Affiliation(s)
- Rasha A Alamoush
- Department of Fixed and Removable Prosthodontics, School of Dentistry, The University of Jordan, Amman, 11942, Jordan
| | - Jiawei Yang
- Department of Prosthodontics, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- National Clinical Research Center for Oral Diseases, College of Stomatology, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Abdulaziz Alhotan
- Department of Dental Health, College of Applied Medical Sciences, King Saud University, 11545, Riyadh, Saudi Arabia
| | - Julfikar Haider
- Department of Engineering, Manchester Metropolitan University, Manchester, M1 5GD, UK
- Division of Dentistry, School of Medical Sciences, The University of Manchester, Manchester, M13 9PL, UK
| | - Jukka P Matinlinna
- Division of Dentistry, School of Medical Sciences, The University of Manchester, Manchester, M13 9PL, UK
| | - Alaaeldin Elraggal
- Operative Dentistry, Conservative Dentistry Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.
| |
Collapse
|
3
|
Lukomska-Szymanska M, Radwanski M, Kharouf N, Mancino D, Tassery H, Caporossi C, Inchingolo F, de Almeida Neves A, Chou YF, Sauro S. Evaluation of Physical-Chemical Properties of Contemporary CAD/CAM Materials with Chromatic Transition "Multicolor". MATERIALS (BASEL, SWITZERLAND) 2023; 16:4189. [PMID: 37297323 PMCID: PMC10254467 DOI: 10.3390/ma16114189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Revised: 05/31/2023] [Accepted: 06/03/2023] [Indexed: 06/12/2023]
Abstract
The use of materials for computer-aided design/computer-aided manufacturing (CAD/CAM) has been rapidly increasing in daily practice. However, one of the main issues regarding modern CAD/CAM materials is their aging in the oral environment, which may lead to significant changes in their overall properties. The aim of this study was to compare the flexural strength, water sorption, cross-link density (softening ratio%), surface roughness, and SEM analysis of three modern CAD/CAM "multicolor" composites. Grandio (Grandio disc multicolor-VOCO GmbH, Cuxhaven, Germany), Shofu (Shofu Block HC-Shofu Inc., Kyoto, Japan), and Vita (Vita Enamic multiColor-Vita Zahnfabrik, Bad Sackingen, Germany) were tested in this study. They were prepared in stick-shaped specimens and submitted to different tests after several aging protocols, such as thermocycling and mechanical cycle loading challenge. Further disc-shaped specimens were also created and tested for water sorption, cross-link density, surface roughness, and SEM ultramorphology, before and after storage in an ethanol-based solution. For flexural strength and ultimate tensile strength, Grandio showed the greatest values both at baseline and after aging (p < 0.05). Grandio and Vita Enamic presented the highest modulus of elasticity and the lowest water sorption (p < 0.05). A significant reduction (p < 0.05) in microhardness after ethanol storage (softening ratio%) was observed especially in Shofu. Grandio had the lowest roughness parameters compared to the other tested CAD/CAM materials, while ethanol storage significantly increased the Ra and RSm values in Shofu (p < 0.05). Despite the comparable modulus of elasticity of Vita and Grandio, this latter showed greater flexural strength and ultimate tensile strength both at baseline and after aging. Hence, Grandio and Vita Enamic may be employed for the anterior teeth and for those restorations requiring load-bearing capacity. Conversely, aging seems to affect several properties of Shofu, so its use for permanent restorations should be well-pondered based on the clinical situation.
Collapse
Affiliation(s)
| | - Mateusz Radwanski
- Department of Endodontics, Medical University of Lodz, 251 Pomorska Str., 92-213 Lodz, Poland;
| | - Naji Kharouf
- Department of Endodontics and Conservative Dentistry, Faculty of Dental Medicine, Strasbourg University, 67000 Strasbourg, France; (N.K.)
- Department of Biomaterials and Bioengineering, INSERM UMR_S 1121, Strasbourg University, 67000 Strasbourg, France
| | - Davide Mancino
- Department of Endodontics and Conservative Dentistry, Faculty of Dental Medicine, Strasbourg University, 67000 Strasbourg, France; (N.K.)
- Department of Biomaterials and Bioengineering, INSERM UMR_S 1121, Strasbourg University, 67000 Strasbourg, France
| | - Herve Tassery
- Ecole de Médecine Dentaire de Marseille, Université d’Aix-Marseille, 13385 Marseille, France
- Laboratoire Bioinginierie et Nanoscience, LBN, Université de Montpellier, 545 Pr JL Viala, 34090 Montpellier, France
| | | | - Francesco Inchingolo
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy
| | - Aline de Almeida Neves
- Department of Pediatric Dentistry and Orthodontics, Universidade Federal do Rio de Janeiro, Rio de Janeiro 21941-853, Brazil
| | - Yu Fu Chou
- Dental Biomaterials and Minimally Invasive Dentistry, Departamento de Odontología, Facultad de Ciencias de la Salud, Universidad CEU-Cardenal Herrera, C/Del Pozo s/n, Alfara del Patriarca, 46115 Valencia, Spain
| | - Salvatore Sauro
- Independent Researcher, Roma, 65B, 00030 Labico, Italy
- Dental Biomaterials and Minimally Invasive Dentistry, Departamento de Odontología, Facultad de Ciencias de la Salud, Universidad CEU-Cardenal Herrera, C/Del Pozo s/n, Alfara del Patriarca, 46115 Valencia, Spain
| |
Collapse
|
4
|
Fuchs F, Schmidtke J, Hahnel S, Koenig A. The influence of different storage media on Vickers hardness and surface roughness of CAD/CAM resin composites. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2023; 34:13. [PMID: 36934208 PMCID: PMC10024666 DOI: 10.1007/s10856-023-06713-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 02/17/2023] [Indexed: 06/18/2023]
Abstract
INTRODUCTION This study examined Vickers hardness as well as surface characteristics of different computer-aided design/computer-aided manufacturing (CAD/CAM) resin composites prior to and after storage in various media. MATERIALS AND METHODS CAD/CAM resin composite blocks (Grandio Blocs (GB), Lava Ultimate (LU), Brilliant Crios (BC), Cerasmart (GC), Shofu Block HC (SB), Tetric CAD (TC), Luxacam Composite (LC); incl. different translucency variants) were prepared, polished and surface free energy was determined. The specimens were divided into four groups: dry conditions for 24 h (25 °C), demineralized water (37 °C), Pepsi Cola (37 °C) and 75% ethanol (37 °C). After seven and 28 days of storage, Vickers hardness was determined. Surface roughness was measured after the entire storage period. RESULTS AND DISCUSSION Vickers hardness was in the range of about 150 HV for GB, around 115 HV for LU, and 80-100 HV for BC, GC, SB, TC and LC. Only minor differences (total: 50.2 (6.4)-56.2 (3.2) mN/m) in surface free energy could be detected. No relationship was observed between surface free energy and filler content. However, a correlation between filler content and Vickers hardness was evident. Artificial aging caused a decrease of Vickers hardness (up to -40 HV or 35%) depending on storage media, duration and material. The changes in surface texture after immersion in different media were below a value of ΔSa = 0.015 µm. CONCLUSION Artificial aging of CAD/CAM resin composites leads to a significant decrease of Vickers hardness for most materials, while only small changes in surface roughness were identified.
Collapse
Affiliation(s)
- Florian Fuchs
- Department of Prosthetic Dentistry and Dental Material Science, Leipzig University, Liebigstraße 12, 04103, Leipzig, Germany.
| | - Julius Schmidtke
- Department of Prosthetic Dentistry and Dental Material Science, Leipzig University, Liebigstraße 12, 04103, Leipzig, Germany
| | - Sebastian Hahnel
- Department of Prosthetic Dentistry, UKR University Hospital Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Germany
| | - Andreas Koenig
- Department of Prosthetic Dentistry and Dental Material Science, Leipzig University, Liebigstraße 12, 04103, Leipzig, Germany
| |
Collapse
|
5
|
Monomers Release from Direct and Indirect Resin-Based Restorations after Immersion in Common Beverages. Polymers (Basel) 2022; 14:polym14235158. [PMID: 36501552 PMCID: PMC9735919 DOI: 10.3390/polym14235158] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2022] [Revised: 11/16/2022] [Accepted: 11/24/2022] [Indexed: 11/30/2022] Open
Abstract
Impurities or degradation of the components of resin-based materials have been throughout investigated by the dental scientific community. The aim of this study is to examine if there is a release of monomers from resin-based materials when they are immersed in common beverage materials which are consumed by the population in large quantities. Three representative dental materials were used for this study, one resin composite indicated for direct restorations and two Computer Aided Design and Computer Aided Manufacturing (CAD/CAM) materials with different methods of fabrication. Forty specimens were fabricated from each material using a low-speed precision sectioning blade 12 × 14 × 2 mm in size and immersed in wine, coffee or cola for 48 h and 12 days, equivalent to 1 month and 1 year of consumption. The materials released more monomers when the materials were immersed in the wine solution (p < 0.05). CAD/CAM materials release less monomers compared to the resin composite material indicated for direct restorations (p < 0.05). The CAD/CAM materials leach a limited quantity of monomers when they are immersed in common beverages due to the manufacturing process which includes high-temperature/high-pressure polymerization.
Collapse
|
6
|
Alghamdi WS, Labban N, Maawadh A, Alsayed HD, Alshehri H, Alrahlah A, Alnafaiy SM. Influence of Acidic Environment on the Hardness, Surface Roughness and Wear Ability of CAD/CAM Resin-Matrix Ceramics. MATERIALS (BASEL, SWITZERLAND) 2022; 15:ma15176146. [PMID: 36079529 PMCID: PMC9457874 DOI: 10.3390/ma15176146] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Revised: 08/30/2022] [Accepted: 08/31/2022] [Indexed: 06/02/2023]
Abstract
This study aimed to measure the effect of storage environment on the hardness, surface roughness and wear ability of CAD/CAM resin-matrix ceramics. A total of 200 rectangular-shaped specimens were obtained by sectioning 5 CAD/CAM blocks; Crystal Ultra (CU), Vita Enamic (VE), Lava Ultimate (LU), Cerasmart (CS) and Vita blocks Mark II (MII). Microhardness and surface roughness were measured at baseline and after 7 days of immersion either in saliva or cola (n = 10). The wear ability of the CAD/CAM materials against steatite-ceramics antagonist was determined using a chewing simulator. The data were statistically analyzed using factorial ANOVA followed by post hoc Bonferroni multiple comparison tests (p < 0.05). The independent factors significantly influenced the microhardness and surface roughness (p < 0.05). The highest VHN was observed in MII at baseline (586.97 ± 13.95), while CU showed the lowest VHN after 7 days of immersion in cola (68.3 ± 1.89). On the contrary, the highest Ra was observed after 120,000 chewing cycles for the VE specimens (1.09 ± 0.43 µm) immersed in cola, while LU showed the lowest Ra at baseline (0.07 ± 0.01 µm). The highest % mass loss of the antagonist was observed with MII immersed in cola (1.801%), while CS demonstrated the lowest % mass loss of 0.004% and 0.007% in AS and cola, respectively. This study confirms that the surface properties of tested CAD/CAM materials are susceptible to degradation in an acidic environment except for hardness and wear of CS material.
Collapse
Affiliation(s)
- Wejdan S. Alghamdi
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia
| | - Nawaf Labban
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia
| | - Ahmed Maawadh
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia
| | - Hussain D. Alsayed
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia
| | - Huda Alshehri
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia
| | - Ali Alrahlah
- Department of Restorative Dental Sciences, Engineer Abdullah Bugshan Research Chair for Dental and Oral Rehabilitation, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia
| | - Sarah M. Alnafaiy
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia
| |
Collapse
|
7
|
Response of human gingival keratinocytes to hybrid CAD/CAM material eluates. Dent Mater 2022; 38:1532-1546. [DOI: 10.1016/j.dental.2022.07.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Revised: 07/13/2022] [Accepted: 07/20/2022] [Indexed: 11/24/2022]
|
8
|
Porojan L, Toma FR, Bîrdeanu MI, Vasiliu RD, Uțu ID, Matichescu A. Surface Characteristics and Color Stability of Dental PEEK Related to Water Saturation and Thermal Cycling. Polymers (Basel) 2022; 14:polym14112144. [PMID: 35683817 PMCID: PMC9183185 DOI: 10.3390/polym14112144] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Revised: 05/15/2022] [Accepted: 05/23/2022] [Indexed: 12/10/2022] Open
Abstract
(1) Background: The study was undertaken to evaluate the surface characteristics, microhardness, and color stability of PEEK materials related to water saturation and in vitro aging. (2) Methods: Custom specimens of unmodified and modified PEEK CAD/CAM materials were investigated: BioHPP, a ceramic reinforced PEEK, and Finoframe PEEK and Juvora medical PEEK, 100% PEEK materials. Forty-eight plates were sectioned in rectangular slices. The specimens were immersed in distilled water at 37 °C for a period of 28 days, and then subjected to aging by thermal cycling (10,000 cycles). Surface roughness was measured with a contact profilometer; nanosurface topographic characterization was made by Atomic Force Microscopy; Vickers hardness measurements were performed with a micro-hardness tester; color changes were calculated. All registrations were made before immersion in water and then subsequently once a week for 4 weeks, and after thermocycling. (3) Results: The studied reinforced and unfilled PEEK materials reached water saturation after the first week of immersion, without significant differences between them. The most affected from this point of view was the reinforced PEEK material. Thermocycling induces a significant increase inmicroroughness, without significant differences between the studied materials. In relation to the nanosurface topography and roughness, the reinforced PEEK material was the least modified by aging. The color changes after 4 weeks of water immersion and one year of simulated in vitro aging ranged from extremely slight to slight, for all materials. (4) Conclusions: Water absorption was associated with a decrease in microhardness. Surface characteristics are affected by water immersion and thermocycling. Perceivable or marked color changes of the materials were not detected during the study.
Collapse
Affiliation(s)
- Liliana Porojan
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, Victor Babeș University of Medicine and Pharmacy Timișoara, Eftimie Murgu Square No. 2, 300041 Timișoara, Romania; (F.R.T.); (R.D.V.)
- Correspondence:
| | - Flavia Roxana Toma
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, Victor Babeș University of Medicine and Pharmacy Timișoara, Eftimie Murgu Square No. 2, 300041 Timișoara, Romania; (F.R.T.); (R.D.V.)
| | - Mihaela Ionela Bîrdeanu
- National Institute for Research and Development in Electrochemistry and Condensed Matter, 300569 Timisoara, Romania;
| | - Roxana Diana Vasiliu
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, Victor Babeș University of Medicine and Pharmacy Timișoara, Eftimie Murgu Square No. 2, 300041 Timișoara, Romania; (F.R.T.); (R.D.V.)
| | - Ion-Dragoș Uțu
- Department of Materials and Fabrication Engineering, Politehnica University Timişoara, Bulevard MihaiViteazul nr.1, 300222 Timişoara, Romania;
| | - Anamaria Matichescu
- Department of Preventive, Community Dentistry and Oral Health, Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy Timișoara, Eftimie Murgu Square No. 2, 300041 Timișoara, Romania;
| |
Collapse
|
9
|
De Angelis F, Sarteur N, Buonvivere M, Vadini M, Šteffl M, D'Arcangelo C. Meta-analytical analysis on components released from resin-based dental materials. Clin Oral Investig 2022; 26:6015-6041. [PMID: 35870020 PMCID: PMC9525379 DOI: 10.1007/s00784-022-04625-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2022] [Accepted: 07/11/2022] [Indexed: 12/24/2022]
Abstract
OBJECTIVES Resin-based materials are applied in every branch of dentistry. Due to their tendency to release substances in the oral environment, doubts have been raised about their actual safety. This review aims to provide a comprehensive analysis of the last decade literature regarding the concentrations of elutable substances released from dental resin-based materials in different type of solvents. MATERIALS AND METHODS All the literature published on dental journals between January 2010 and April 2022 was searched using international databases (PubMed, Scopus, Web of Science). Due to strict inclusion criteria, only 23 papers out of 877 were considered eligible. The concentration of eluted substances related to surface and volume of the sample was analyzed, considering data at 24 h as a reference. The total cumulative release was examined as well. RESULTS The most eluted substances were HEMA, TEGDMA, and BPA, while the less eluted were Bis-GMA and UDMA. Organic solvents caused significantly higher release of substances than water-based ones. A statistically significant inverse correlation between the release of molecules and their molecular mass was observed. A statistically significant positive correlation between the amount of released molecule and the specimen surface area was detected, as well as a weak positive correlation between the release and the specimen volume. CONCLUSIONS Type of solvent, molecular mass of eluates, and specimen surface and volume affect substances release from materials. CLINICAL RELEVANCE It could be advisable to rely on materials based on monomers with a reduced elution tendency for clinical procedures.
Collapse
Affiliation(s)
- Francesco De Angelis
- Unit of Restorative Dentistry and Endodontics, Department of Medical, Oral and Biotechnological Sciences, School of Dentistry, "G. D'Annunzio" University Chieti-Pescara, Via dei Vestini, 31, 66100, Chieti, Italy.
| | - Nela Sarteur
- Unit of Restorative Dentistry and Endodontics, Department of Medical, Oral and Biotechnological Sciences, School of Dentistry, "G. D'Annunzio" University Chieti-Pescara, Via dei Vestini, 31, 66100, Chieti, Italy
| | - Matteo Buonvivere
- Unit of Restorative Dentistry and Endodontics, Department of Medical, Oral and Biotechnological Sciences, School of Dentistry, "G. D'Annunzio" University Chieti-Pescara, Via dei Vestini, 31, 66100, Chieti, Italy
| | - Mirco Vadini
- Unit of Restorative Dentistry and Endodontics, Department of Medical, Oral and Biotechnological Sciences, School of Dentistry, "G. D'Annunzio" University Chieti-Pescara, Via dei Vestini, 31, 66100, Chieti, Italy
| | - Michal Šteffl
- Department of Physiology and Biochemistry, Faculty of Physical Education and Sport, Charles University, Prague, Czech Republic
| | - Camillo D'Arcangelo
- Unit of Restorative Dentistry and Endodontics, Department of Medical, Oral and Biotechnological Sciences, School of Dentistry, "G. D'Annunzio" University Chieti-Pescara, Via dei Vestini, 31, 66100, Chieti, Italy
| |
Collapse
|