Bester M, Nichting TJ, Joshi R, Aissati L, Oei GS, Mischi M, van Laar JOEH, Vullings R. Changes in Maternal Heart Rate Variability and Photoplethysmography Morphology after Corticosteroid Administration: A Prospective, Observational Study. J Clin Med 2024; 13:2442. [PMID: 38673715 PMCID: PMC11051424 DOI: 10.3390/jcm13082442] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2024] [Revised: 04/17/2024] [Accepted: 04/18/2024] [Indexed: 04/28/2024] Open
Abstract
Background: Owing to the association between dysfunctional maternal autonomic regulation and pregnancy complications, assessing non-invasive features reflecting autonomic activity-e.g., heart rate variability (HRV) and the morphology of the photoplethysmography (PPG) pulse wave-may aid in tracking maternal health. However, women with early pregnancy complications typically receive medication, such as corticosteroids, and the effect of corticosteroids on maternal HRV and PPG pulse wave morphology is not well-researched. Methods: We performed a prospective, observational study assessing the effect of betamethasone (a commonly used corticosteroid) on non-invasively assessed features of autonomic regulation. Sixty-one women with an indication for betamethasone were enrolled and wore a wrist-worn PPG device for at least four days, from which five-minute measurements were selected for analysis. A baseline measurement was selected either before betamethasone administration or sufficiently thereafter (i.e., three days after the last injection). Furthermore, measurements were selected 24, 48, and 72 h after betamethasone administration. HRV features in the time domain and frequency domain and describing heart rate (HR) complexity were calculated, along with PPG morphology features. These features were compared between the different days. Results: Maternal HR was significantly higher and HRV features linked to parasympathetic activity were significantly lower 24 h after betamethasone administration. Features linked to sympathetic activity remained stable. Furthermore, based on the PPG morphology features, betamethasone appears to have a vasoconstrictive effect. Conclusions: Our results suggest that administering betamethasone affects maternal autonomic regulation and cardiovasculature. Researchers assessing maternal HRV in complicated pregnancies should schedule measurements before or sufficiently after corticosteroid administration.
Collapse
Affiliation(s)
- Maretha Bester
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
- Patient Care and Monitoring, Philips Research, 5656 AE Eindhoven, The Netherlands
| | - Thomas J. Nichting
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
- Department of Obstetrics and Gynecology, Máxima Medical Centrum, 5504 DB Veldhoven, The Netherlands
| | - Rohan Joshi
- Patient Care and Monitoring, Philips Research, 5656 AE Eindhoven, The Netherlands
| | - Lamyae Aissati
- Faculty of Health, Medicine and Life Science, Maastricht University, 6229 ER Maastricht, The Netherlands
| | - Guid S. Oei
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
- Department of Obstetrics and Gynecology, Máxima Medical Centrum, 5504 DB Veldhoven, The Netherlands
| | - Massimo Mischi
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
| | - Judith O. E. H. van Laar
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
- Department of Obstetrics and Gynecology, Máxima Medical Centrum, 5504 DB Veldhoven, The Netherlands
| | - Rik Vullings
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
| |
Collapse
|
2
|
Changes in Maternal Heart Rate and Autonomic Regulation following the Antenatal Administration of Corticosteroids: A Secondary Analysis. J Clin Med 2023; 12:jcm12020588. [PMID: 36675517 PMCID: PMC9866172 DOI: 10.3390/jcm12020588] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Revised: 01/07/2023] [Accepted: 01/09/2023] [Indexed: 01/13/2023] Open
Abstract
While the effect of antenatally administered corticosteroids on fetal heart rate (HR) and heart rate variability (HRV) is well established, little information is available on how these drugs affect maternal physiology. In this secondary analysis of a prospective, observational cohort study, we quantify how corticosteroids affect maternal HR and HRV, which serve as a proxy measure for autonomic regulation. Abdominal ECG measurements were recorded before and in the five days following the administration of betamethasone—a corticosteroid commonly used for fetal maturation—in 46 women with singleton pregnancies. Maternal HR and HRV were determined from these recordings and compared between these days. HRV was assessed with time- and frequency-domain features, as well as non-linear and complexity features. In the 24 h after betamethasone administration, maternal HR was significantly increased (p < 0.01) by approximately 10 beats per minute, while HRV features linked to parasympathetic activity and HR complexity were significantly decreased (p < 0.01 and p < 0.001, respectively). Within four days after the initial administration of betamethasone, HR decreases and HRV features increase again, indicating a diminishing effect of betamethasone a few days after administration. We conclude that betamethasone administration results in changes in maternal HR and HRV, despite the heterogeneity of the studied population. Therefore, its recent administration should be considered when evaluating these cardiovascular metrics.
Collapse
|
3
|
Cerritelli F, Frasch MG, Antonelli MC, Viglione C, Vecchi S, Chiera M, Manzotti A. A Review on the Vagus Nerve and Autonomic Nervous System During Fetal Development: Searching for Critical Windows. Front Neurosci 2021; 15:721605. [PMID: 34616274 PMCID: PMC8488382 DOI: 10.3389/fnins.2021.721605] [Citation(s) in RCA: 36] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Accepted: 08/19/2021] [Indexed: 12/17/2022] Open
Abstract
The autonomic nervous system (ANS) is one of the main biological systems that regulates the body's physiology. Autonomic nervous system regulatory capacity begins before birth as the sympathetic and parasympathetic activity contributes significantly to the fetus' development. In particular, several studies have shown how vagus nerve is involved in many vital processes during fetal, perinatal, and postnatal life: from the regulation of inflammation through the anti-inflammatory cholinergic pathway, which may affect the functioning of each organ, to the production of hormones involved in bioenergetic metabolism. In addition, the vagus nerve has been recognized as the primary afferent pathway capable of transmitting information to the brain from every organ of the body. Therefore, this hypothesis paper aims to review the development of ANS during fetal and perinatal life, focusing particularly on the vagus nerve, to identify possible "critical windows" that could impact its maturation. These "critical windows" could help clinicians know when to monitor fetuses to effectively assess the developmental status of both ANS and specifically the vagus nerve. In addition, this paper will focus on which factors-i.e., fetal characteristics and behaviors, maternal lifestyle and pathologies, placental health and dysfunction, labor, incubator conditions, and drug exposure-may have an impact on the development of the vagus during the above-mentioned "critical window" and how. This analysis could help clinicians and stakeholders define precise guidelines for improving the management of fetuses and newborns, particularly to reduce the potential adverse environmental impacts on ANS development that may lead to persistent long-term consequences. Since the development of ANS and the vagus influence have been shown to be reflected in cardiac variability, this paper will rely in particular on studies using fetal heart rate variability (fHRV) to monitor the continued growth and health of both animal and human fetuses. In fact, fHRV is a non-invasive marker whose changes have been associated with ANS development, vagal modulation, systemic and neurological inflammatory reactions, and even fetal distress during labor.
Collapse
Affiliation(s)
- Francesco Cerritelli
- Research and Assistance for Infants to Support Experience Lab, Foundation Center for Osteopathic Medicine Collaboration, Pescara, Italy
| | - Martin G. Frasch
- Department of Obstetrics and Gynecology and Center on Human Development and Disability, University of Washington, Seattle, WA, United States
| | - Marta C. Antonelli
- Facultad de Medicina, Instituto de Biología Celular y Neurociencia “Prof. E. De Robertis”, Universidad de Buenos Aires, Buenos Aires, Argentina
- Department of Obstetrics and Gynecology, Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany
| | - Chiara Viglione
- Research and Assistance for Infants to Support Experience Lab, Foundation Center for Osteopathic Medicine Collaboration, Pescara, Italy
| | - Stefano Vecchi
- Research and Assistance for Infants to Support Experience Lab, Foundation Center for Osteopathic Medicine Collaboration, Pescara, Italy
| | - Marco Chiera
- Research and Assistance for Infants to Support Experience Lab, Foundation Center for Osteopathic Medicine Collaboration, Pescara, Italy
| | - Andrea Manzotti
- Research and Assistance for Infants to Support Experience Lab, Foundation Center for Osteopathic Medicine Collaboration, Pescara, Italy
- Department of Pediatrics, Division of Neonatology, “V. Buzzi” Children's Hospital, Azienda Socio-Sanitaria Territoriale Fatebenefratelli Sacco, Milan, Italy
- Research Department, Istituto Osteopatia Milano, Milan, Italy
| |
Collapse
|
4
|
The Noninvasive Fetal Electrocardiogram During Labor: A Review of the Literature. Obstet Gynecol Surv 2021; 75:369-380. [PMID: 32603475 DOI: 10.1097/ogx.0000000000000798] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Importance The introduction of the cardiotocogram (CTG) during labor has not been found to improve neonatal outcome. The search for a more reliable, less invasive, and patient-friendly technique is ongoing. The noninvasive fetal electrocardiogram (NI-fECG) has been proposed as one such alternative. Objectives The aim of this study was to review the literature on the performance of NI-fECG for fetal monitoring during labor. Following the PRISMA guidelines, a systematic search in MEDLINE, EMBASE, and Cochrane Library was performed. Studies involving original research investigating the performance of NI-fECG during labor were included. Animal studies and articles in languages other than English, Dutch, or German were excluded. The QUADAS-2 checklist was used for quality assessment. A descriptive analysis of the results is provided. Results Eight articles were included. Pooled analysis of the results of the separate studies was not possible due to heterogeneity. All studies demonstrate that it is possible to apply NI-fECG during labor. Compared with Doppler ultrasound, NI-fECG performs equal or better in most studies. Conclusions and Relevance NI-fECG for fetal monitoring is a promising noninvasive and patient-friendly technique that provides accurate information. Future studies should focus on signal quality throughout labor, with the aim to further optimize technical development of NI-fECG.
Collapse
|
5
|
Bester M, Moors S, Joshi R, Nichting TJ, van der Hout-van der Jagt MB, Oei SG, Mischi M, Vullings R, van Laar JOEH. Changes in Maternal Heart Rate Variability in Response to the Administration of Routine Obstetric Medication in Hospitalized Patients: Study Protocol for a Cohort Study (MAMA-Heart Study). Clin Pract 2021; 11:13-25. [PMID: 33599215 PMCID: PMC7838947 DOI: 10.3390/clinpract11010004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2020] [Revised: 01/15/2021] [Accepted: 01/18/2021] [Indexed: 12/05/2022] Open
Abstract
Pregnancy is a period of continuous change in the maternal cardiovascular system, partly mediated by the autonomic nervous system. Insufficient autonomic adaptation to increasing gestation is associated with pregnancy complications, such as hypertensive disorders of pregnancy and preterm birth (both major causes of perinatal morbidity and mortality). Consequently, maternal heart rate variability (mHRV), which is a proxy measure for autonomic activity, is increasingly assessed in these cohorts to investigate the pathophysiology of their complications. A better pathophysiological understanding could facilitate the early detection of these complications, which remains challenging. However, such studies (typically performed in pregnancies leading to hospitalization) have generated conflicting findings. A probable reason for these conflicting findings is that these study cohorts were likely administered routine obstetric medications during the study period of which the effects on mHRV are largely unknown. Subsequently, we design a longitudinal, observational study to quantifying the effect of these medications-particularly corticosteroids, which are known to affect fetal HRV-on mHRV to improve the interpretation of past and future studies. We will enroll 61 women admitted to a tertiary obstetric unit with an indication to receive corticosteroids antenatally. Participants' mHRV will be continuously acquired throughout their hospitalization with wrist-worn photoplethysmography to facilitate a within-patient comparison of the effect of corticosteroids on mHRV.
Collapse
Affiliation(s)
- Maretha Bester
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AP Eindhoven, The Netherlands; (S.M.); (T.J.N.); (M.B.v.d.H.-v.d.J.); (S.G.O.); (M.M.); (R.V.); (J.O.E.H.v.L.)
- Department of Family Care Solutions, Philips Research, 5656 AE Eindhoven, The Netherlands;
| | - Suzanne Moors
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AP Eindhoven, The Netherlands; (S.M.); (T.J.N.); (M.B.v.d.H.-v.d.J.); (S.G.O.); (M.M.); (R.V.); (J.O.E.H.v.L.)
- Department of Obstetrics and Gynecology, Máxima MC, 5504 DB Veldhoven, The Netherlands
| | - Rohan Joshi
- Department of Family Care Solutions, Philips Research, 5656 AE Eindhoven, The Netherlands;
| | - Thomas J. Nichting
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AP Eindhoven, The Netherlands; (S.M.); (T.J.N.); (M.B.v.d.H.-v.d.J.); (S.G.O.); (M.M.); (R.V.); (J.O.E.H.v.L.)
- Department of Obstetrics and Gynecology, Máxima MC, 5504 DB Veldhoven, The Netherlands
| | - M. Beatrijs van der Hout-van der Jagt
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AP Eindhoven, The Netherlands; (S.M.); (T.J.N.); (M.B.v.d.H.-v.d.J.); (S.G.O.); (M.M.); (R.V.); (J.O.E.H.v.L.)
- Department of Obstetrics and Gynecology, Máxima MC, 5504 DB Veldhoven, The Netherlands
- Department of Biomedical Engineering, Eindhoven University of Technology, 5612 AP Eindhoven, The Netherlands
| | - S. Guid Oei
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AP Eindhoven, The Netherlands; (S.M.); (T.J.N.); (M.B.v.d.H.-v.d.J.); (S.G.O.); (M.M.); (R.V.); (J.O.E.H.v.L.)
- Department of Obstetrics and Gynecology, Máxima MC, 5504 DB Veldhoven, The Netherlands
| | - Massimo Mischi
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AP Eindhoven, The Netherlands; (S.M.); (T.J.N.); (M.B.v.d.H.-v.d.J.); (S.G.O.); (M.M.); (R.V.); (J.O.E.H.v.L.)
| | - Rik Vullings
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AP Eindhoven, The Netherlands; (S.M.); (T.J.N.); (M.B.v.d.H.-v.d.J.); (S.G.O.); (M.M.); (R.V.); (J.O.E.H.v.L.)
| | - Judith O. E. H. van Laar
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AP Eindhoven, The Netherlands; (S.M.); (T.J.N.); (M.B.v.d.H.-v.d.J.); (S.G.O.); (M.M.); (R.V.); (J.O.E.H.v.L.)
- Department of Obstetrics and Gynecology, Máxima MC, 5504 DB Veldhoven, The Netherlands
| |
Collapse
|
6
|
Tamber KK, Hayes DJL, Carey SJ, Wijekoon JHB, Heazell AEP. A systematic scoping review to identify the design and assess the performance of devices for antenatal continuous fetal monitoring. PLoS One 2020; 15:e0242983. [PMID: 33259507 PMCID: PMC7707469 DOI: 10.1371/journal.pone.0242983] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Accepted: 11/12/2020] [Indexed: 12/29/2022] Open
Abstract
BACKGROUND Antepartum fetal monitoring aims to assess fetal development and wellbeing throughout pregnancy. Current methods utilised in clinical practice are intermittent and only provide a 'snapshot' of fetal wellbeing, thus key signs of fetal demise could be missed. Continuous fetal monitoring (CFM) offers the potential to alleviate these issues by providing an objective and longitudinal overview of fetal status. Various CFM devices exist within literature; this review planned to provide a systematic overview of these devices, and specifically aimed to map the devices' design, performance and factors which affect this, whilst determining any gaps in development. METHODS A systematic search was conducted using MEDLINE, EMBASE, CINAHL, EMCARE, BNI, Cochrane Library, Web of Science and Pubmed databases. Following the deletion of duplicates, the articles' titles and abstracts were screened and suitable papers underwent a full-text assessment prior to inclusion in the review by two independent assessors. RESULTS The literature searches generated 4,885 hits from which 43 studies were included in the review. Twenty-four different devices were identified utilising four suitable CFM technologies: fetal electrocardiography, fetal phonocardiography, accelerometry and fetal vectorcardiography. The devices adopted various designs and signal processing methods. There was no common means of device performance assessment between different devices, which limited comparison. The device performance of fetal electrocardiography was reduced between 28 to 36 weeks' gestation and during high levels of maternal movement, and increased during night-time rest. Other factors, including maternal body mass index, fetal position, recording location, uterine activity, amniotic fluid index, number of fetuses and smoking status, as well as factors which affected alternative technologies had equivocal effects and require further investigation. CONCLUSIONS A variety of CFM devices have been developed, however no specific approach or design appears to be advantageous due to high levels of inter-device and intra-device variability.
Collapse
Affiliation(s)
- Kajal K. Tamber
- Faculty of Biology, Division of Developmental Biology and Medicine, Maternal and Fetal Health Research Centre, School of Medical Sciences, Medicine and Health, University of Manchester, St. Mary’s Hospital, Manchester, United Kingdom
| | - Dexter J. L. Hayes
- Faculty of Biology, Division of Developmental Biology and Medicine, Maternal and Fetal Health Research Centre, School of Medical Sciences, Medicine and Health, University of Manchester, St. Mary’s Hospital, Manchester, United Kingdom
| | - Stephen J. Carey
- School of Electrical and Electronic Engineering, University of Manchester, Manchester, United Kingdom
| | - Jayawan H. B. Wijekoon
- School of Electrical and Electronic Engineering, University of Manchester, Manchester, United Kingdom
| | - Alexander E. P. Heazell
- Faculty of Biology, Division of Developmental Biology and Medicine, Maternal and Fetal Health Research Centre, School of Medical Sciences, Medicine and Health, University of Manchester, St. Mary’s Hospital, Manchester, United Kingdom
- Manchester University NHS Foundation Trust, St. Mary’s Hospital, Manchester Academic Health Science Centre, Manchester, United Kingdom
| |
Collapse
|
7
|
Moors S, Staaks KJJ, Westerhuis MEMH, Dekker LRC, Verdurmen KMJ, Oei SG, van Laar JOEH. Heart rate variability in hypertensive pregnancy disorders: A systematic review. Pregnancy Hypertens 2020; 20:56-68. [PMID: 32179490 DOI: 10.1016/j.preghy.2020.03.003] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2019] [Revised: 02/28/2020] [Accepted: 03/02/2020] [Indexed: 02/07/2023]
Abstract
BACKGROUND Hypertensive pregnancy disorders (HPD) are associated with dysfunction of the autonomic nervous system. Cardiac autonomic functions can be assessed by heart rate variability (HRV) measurements. OBJECTIVE To study whether HRV detects differences in the function of the autonomic nervous system between pregnant women with HPD compared to normotensive pregnant women and between women with a history of a pregnancy complicated by HPD compared to women with a history of an uncomplicated pregnancy. METHODS A systematic search was performed in Medline, EMBASE, and CENTRAL to identify studies comparing HRV between pregnant women with HPD or women with a history of HPD to women with (a history of) normotensive pregnancies. RESULTS The search identified 523 articles of which 24 were included in this review, including 850 women with (a history of) HPD and 1205 normotensive controls. The included studies showed a large heterogenicity. A decrease in overall HRV was found in preeclampsia (PE), compared to normotensive pregnant controls. A trend is seen towards increased low frequency/high frequency-ratio in women with PE compared to normotensive pregnant controls. CONCLUSION Our systematic review supports the hypothesis a sympathetic overdrive is found in HPD which is associated with a parasympathetic withdrawal. However, the included studies in our review showed a large diversity in the methods applied and their results.
Collapse
Affiliation(s)
- S Moors
- Department of Obstetrics and Gynecology, Máxima Medical Center, Veldhoven, The Netherlands; Eindhoven MedTech Innovation Center (e/MTIC), Eindhoven, The Netherlands; Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
| | - K J J Staaks
- Department of Obstetrics and Gynecology, Máxima Medical Center, Veldhoven, The Netherlands
| | - M E M H Westerhuis
- Eindhoven MedTech Innovation Center (e/MTIC), Eindhoven, The Netherlands; Department of Obstetrics and Gynecology, Catharina Hospital, Eindhoven, The Netherlands
| | - L R C Dekker
- Eindhoven MedTech Innovation Center (e/MTIC), Eindhoven, The Netherlands; Department of Cardiology, Catharina Hospital, Eindhoven, The Netherlands; Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - K M J Verdurmen
- Department of Obstetrics and Gynecology, Máxima Medical Center, Veldhoven, The Netherlands
| | - S G Oei
- Department of Obstetrics and Gynecology, Máxima Medical Center, Veldhoven, The Netherlands; Eindhoven MedTech Innovation Center (e/MTIC), Eindhoven, The Netherlands; Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - J O E H van Laar
- Department of Obstetrics and Gynecology, Máxima Medical Center, Veldhoven, The Netherlands; Eindhoven MedTech Innovation Center (e/MTIC), Eindhoven, The Netherlands; Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| |
Collapse
|
8
|
Abstract
Preterm birth occurs with 10% of deliveries and yet accounts for more than 85% of perinatal morbidity and mortality. Management of preterm labor prior to delivery includes a multipronged pharmacologic approach targeting utilization of reproductive hormones for continuation of pregnancy, advancement of fetal lung maturity, and the decrease of uterine contractility (tocolysis). This article will review and compare guidelines on pharmacologic management of preterm labor as recommended by the American College of Obstetricians and Gynecologists and the European Association of Perinatal Medicine. The classifications of drugs discussed include exogenous progesterone, corticosteroids, and tocolytics (β-adrenergic agonists, magnesium sulfate, calcium channel blockers, prostaglandin inhibitors, nitrates, and oxytocin receptor blockers). For each of these drug classes, the following information will be presented: mechanism of action, maternal/fetal side effects, and nursing implications.
Collapse
|
9
|
Noben L, Verdurmen KMJ, Warmerdam GJJ, Vullings R, Oei SG, van Laar JOEH. The fetal electrocardiogram to detect the effects of betamethasone on fetal heart rate variability. Early Hum Dev 2019; 130:57-64. [PMID: 30677639 DOI: 10.1016/j.earlhumdev.2019.01.011] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/22/2018] [Revised: 01/15/2019] [Accepted: 01/15/2019] [Indexed: 10/27/2022]
Abstract
BACKGROUND Betamethasone is widely used to enhance fetal lung maturation in case of threatened preterm birth. Antenatal corticosteroids are known to reduce fetal heart rate variability (fHRV) in the days following administration. Since decreased fHRV is a marker for fetal distress, this transient decrease of fHRV can cause unnecessary medical intervention. AIM To describe the effect of betamethasone on fHRV, by applying spectral analysis on non-invasive fetal electrocardiogram (fECG) recordings. STUDY DESIGN Secondary analysis of a prospective cohort study. SUBJECTS Women with a singleton pregnancy, at risk for preterm delivery and receiving betamethasone, admitted to the obstetric high care unit in the period from March 2013 until July 2016. OUTCOME MEASURES The primary outcome measure was fHRV in both time- and frequency-domain. Secondary outcome measures included basal fetal heart rate (fHR) and fHR variance. FHRV parameters were then calculated separately for the quiet and active state. RESULTS Following 68 inclusions, 22 patients remained with complete series of measurements and sufficient data quality. FHRV parameters and fHR showed a decrease on day 2 compared to day 1, significant for short-term variability and high-frequency power. Similar results were found when analyzing for separate behavioral states. The number of segments in quiet state increased during days 1 and 2. Normalized values showed no difference for all behavioral states. CONCLUSION FHRV decreases on day 2 after betamethasone administration, while periods of fetal quiescence increase. No changes were found in the normalized values, indicating that the influence of autonomic modulation is minor. Clinical trial registration number NL43294.015.13.
Collapse
Affiliation(s)
- L Noben
- Department of Obstetrics and Gynecology, Maxima Medical Center, Veldhoven, the Netherlands; Eindhoven MedTech Innovation Center (e/MTIC), Eindhoven, the Netherlands.
| | - K M J Verdurmen
- Department of Obstetrics and Gynecology, Maxima Medical Center, Veldhoven, the Netherlands; Eindhoven MedTech Innovation Center (e/MTIC), Eindhoven, the Netherlands
| | - G J J Warmerdam
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands; Eindhoven MedTech Innovation Center (e/MTIC), Eindhoven, the Netherlands
| | - R Vullings
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands; Eindhoven MedTech Innovation Center (e/MTIC), Eindhoven, the Netherlands
| | - S G Oei
- Department of Obstetrics and Gynecology, Maxima Medical Center, Veldhoven, the Netherlands; Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands
| | - J O E H van Laar
- Department of Obstetrics and Gynecology, Maxima Medical Center, Veldhoven, the Netherlands; Eindhoven MedTech Innovation Center (e/MTIC), Eindhoven, the Netherlands
| |
Collapse
|
10
|
Smith V, Arunthavanathan S, Nair A, Ansermet D, da Silva Costa F, Wallace EM. A systematic review of cardiac time intervals utilising non-invasive fetal electrocardiogram in normal fetuses. BMC Pregnancy Childbirth 2018; 18:370. [PMID: 30208861 PMCID: PMC6134593 DOI: 10.1186/s12884-018-2006-8] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2018] [Accepted: 09/02/2018] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Non-invasive fetal electrocardiogram (NIFECG) is an evolving technology in fetal surveillance which is attracting increasing research interest. There is however, only limited data outlining the reference ranges for normal cardiac time intervals (CTIs). The objective of our group was to carry out a systematic review to outline normal fetal CTIs using NIFECG. METHODS A systematic review of peer reviewed literature was performed, searching PUBMED,Ovid MEDLINE and EMBASE. The outcomes of interest included fetal CTIs (P wave duration, PR interval, QRS duration and QT interval) and a descriptive summary of relevant studies as well. The outcomes were grouped as early pre-term (≤ 32 weeks), moderate to late pre-term (32-37 weeks) and term (37-41 weeks). RESULTS 8 studies were identified as suitable for inclusion. Reference ranges of CTIs were generated. Both PR interval and QRS duration demonstrated a linear correlation with advancing gestation. Several studies also demonstrated a reduction in signal acquisition between 27 and 32 weeks due to the attenuation by vernix caseosa. In this group, both the P wave and T waves were difficult to detect due to signal strength and interference. CONCLUSION NIFECG demonstrates utility to quantify CTIs in the fetus, particularly at advanced gestations. Larger prospective studies should be directed towards establishing reliable CTIs across various gestations.
Collapse
Affiliation(s)
- Vinayak Smith
- Department of Obstetrics and Gynaecology, Monash University, 252 Clayton Road, Melbourne, VIC, 3168, Australia.
- Biorithm Pte Ltd, 81 Ayer Rajah Crescent 03-53, Singapore, 139967, Singapore.
| | - Senthuran Arunthavanathan
- Department of Electrical and Electronic Engineering, University of Melbourne, Parkville Campus, Melbourne, VIC, 3010, Australia
| | - Amrish Nair
- Biorithm Pte Ltd, 81 Ayer Rajah Crescent 03-53, Singapore, 139967, Singapore
| | - Diane Ansermet
- Biorithm Pte Ltd, 81 Ayer Rajah Crescent 03-53, Singapore, 139967, Singapore
| | - Fabricio da Silva Costa
- Department of Obstetrics and Gynaecology, Monash University, 252 Clayton Road, Melbourne, VIC, 3168, Australia
| | - Euan Morrison Wallace
- Department of Obstetrics and Gynaecology, Monash University, 252 Clayton Road, Melbourne, VIC, 3168, Australia
| |
Collapse
|