1
|
Ece E, Ölmez K, Hacıosmanoğlu N, Atabay M, Inci F. Advancing 3D printed microfluidics with computational methods for sweat analysis. Mikrochim Acta 2024; 191:162. [PMID: 38411762 PMCID: PMC10899357 DOI: 10.1007/s00604-024-06231-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Accepted: 01/18/2024] [Indexed: 02/28/2024]
Abstract
The intricate tapestry of biomarkers, including proteins, lipids, carbohydrates, vesicles, and nucleic acids within sweat, exhibits a profound correlation with the ones in the bloodstream. The facile extraction of samples from sweat glands has recently positioned sweat sampling at the forefront of non-invasive health monitoring and diagnostics. While extant platforms for sweat analysis exist, the imperative for portability, cost-effectiveness, ease of manufacture, and expeditious turnaround underscores the necessity for parameters that transcend conventional considerations. In this regard, 3D printed microfluidic devices emerge as promising systems, offering a harmonious fusion of attributes such as multifunctional integration, flexibility, biocompatibility, a controlled closed environment, and a minimal requisite analyte volume-features that leverage their prominence in the realm of sweat analysis. However, formidable challenges, including high throughput demands, chemical interactions intrinsic to the printing materials, size constraints, and durability concerns, beset the landscape of 3D printed microfluidic devices. Within this paradigm, we expound upon the foundational aspects of 3D printed microfluidic devices and proffer a distinctive perspective by delving into the computational study of printing materials utilizing density functional theory (DFT) and molecular dynamics (MD) methodologies. This multifaceted approach serves manifold purposes: (i) understanding the complexity of microfluidic systems, (ii) facilitating comprehensive analyses, (iii) saving both cost and time, (iv) improving design optimization, and (v) augmenting resolution. In a nutshell, the allure of 3D printing lies in its capacity for affordable and expeditious production, offering seamless integration of diverse components into microfluidic devices-a testament to their inherent utility in the domain of sweat analysis. The synergistic fusion of computational assessment methodologies with materials science not only optimizes analysis and production processes, but also expedites their widespread accessibility, ensuring continuous biomarker monitoring from sweat for end-users.
Collapse
Affiliation(s)
- Emre Ece
- UNAM-National Nanotechnology Research Center, Bilkent University, 06800, Ankara, Turkey
- Institute of Materials Science and Nanotechnology, Bilkent University, 06800, Ankara, Turkey
| | - Kadriye Ölmez
- UNAM-National Nanotechnology Research Center, Bilkent University, 06800, Ankara, Turkey
- Institute of Materials Science and Nanotechnology, Bilkent University, 06800, Ankara, Turkey
| | - Nedim Hacıosmanoğlu
- UNAM-National Nanotechnology Research Center, Bilkent University, 06800, Ankara, Turkey
- Institute of Materials Science and Nanotechnology, Bilkent University, 06800, Ankara, Turkey
| | - Maryam Atabay
- UNAM-National Nanotechnology Research Center, Bilkent University, 06800, Ankara, Turkey
- Department of Chemistry, Hacettepe University, 06800, Ankara, Turkey
| | - Fatih Inci
- UNAM-National Nanotechnology Research Center, Bilkent University, 06800, Ankara, Turkey.
- Institute of Materials Science and Nanotechnology, Bilkent University, 06800, Ankara, Turkey.
| |
Collapse
|
2
|
Mundee T, Jongwannasiri C, Fuangrod T. Design of 3D-printed universal oral stent for tongue immobilization in head and neck radiotherapy. Biomed Phys Eng Express 2022; 9. [PMID: 36583442 DOI: 10.1088/2057-1976/aca9d4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Accepted: 12/08/2022] [Indexed: 12/13/2022]
Abstract
The primary treatment for head and neck cancer is radiotherapy, which can cause complications and effects, such as the ability to speak, taste, produce saliva, and swallow. An oral stent is an immobilization tool for minimizing the dose in the tongue (or hard palate) by locking the tongue position during radiation delivery. It can improve the treatment accuracy due to less uncertainty caused by tongue position uncertainty between treatment fractions. However, commercial oral stents are not widely adopted in developing countries due to their unaffordable price. This study aimed to design the universal oral stent (UOS) to achieve high efficiency, ease to use, and low-cost fabrication based on 3D printing technology. There were five experiments to evaluate the UOS design and fabrication versus the modified cut syringe, including finite element analysis (FEA), the usability test, the micro Vickers hardness test, single beam dose analysis, and dose calculation on treatment plan simulations. The proposed UOS design and fabrication presented a high capability to apply for clinical use.
Collapse
Affiliation(s)
- Thunpisit Mundee
- Princess Srisavangavadhana College of Medicine, Chulabhorn Royal Academy, Bangkok, 10210, Thailand.,Department of Radiation Oncology, Oncology Medical Center Chulabhorn, Chulabhorn Royal Academy, Bangkok, 10210, Thailand
| | - Chavin Jongwannasiri
- Princess Srisavangavadhana College of Medicine, Chulabhorn Royal Academy, Bangkok, 10210, Thailand
| | - Todsaporn Fuangrod
- Princess Srisavangavadhana College of Medicine, Chulabhorn Royal Academy, Bangkok, 10210, Thailand.,Department of Radiation Oncology, Oncology Medical Center Chulabhorn, Chulabhorn Royal Academy, Bangkok, 10210, Thailand
| |
Collapse
|
3
|
El Hawari W, Bentahar O. Protective and positioning devices in maxillofacial prosthodontics and radiotherapy: Overview. Tech Innov Patient Support Radiat Oncol 2022; 24:118-123. [DOI: 10.1016/j.tipsro.2022.11.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Revised: 10/15/2022] [Accepted: 11/08/2022] [Indexed: 11/18/2022] Open
|
4
|
Wu Y, Lu Y, Zhao M, Bosiakov S, Li L. A Critical Review of Additive Manufacturing Techniques and Associated Biomaterials Used in Bone Tissue Engineering. Polymers (Basel) 2022; 14:polym14102117. [PMID: 35631999 PMCID: PMC9143308 DOI: 10.3390/polym14102117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2022] [Revised: 04/21/2022] [Accepted: 05/11/2022] [Indexed: 12/10/2022] Open
Abstract
With the ability to fabricate complex structures while meeting individual needs, additive manufacturing (AM) offers unprecedented opportunities for bone tissue engineering in the biomedical field. However, traditional metal implants have many adverse effects due to their poor integration with host tissues, and therefore new material implants with porous structures are gradually being developed that are suitable for clinical medical applications. From the perspectives of additive manufacturing technology and materials, this article discusses a suitable manufacturing process for ideal materials for biological bone tissue engineering. It begins with a review of the methods and applicable materials in existing additive manufacturing technologies and their applications in biomedicine, introducing the advantages and disadvantages of various AM technologies. The properties of materials including metals and polymers, commonly used AM technologies, recent developments, and their applications in bone tissue engineering are discussed in detail and summarized. In addition, the main challenges for different metallic and polymer materials, such as biodegradability, anisotropy, growth factors to promote the osteogenic capacity, and enhancement of mechanical properties are also introduced. Finally, the development prospects for AM technologies and biomaterials in bone tissue engineering are considered.
Collapse
Affiliation(s)
- Yanli Wu
- Department of Engineering Mechanics, Dalian University of Technology, No. 2 Linggong Road, Dalian 116024, China; (Y.W.); (Y.L.); (M.Z.)
| | - Yongtao Lu
- Department of Engineering Mechanics, Dalian University of Technology, No. 2 Linggong Road, Dalian 116024, China; (Y.W.); (Y.L.); (M.Z.)
- DUT-BSU Joint Institute, Dalian University of Technology, No. 2 Linggong Road, Dalian 116024, China
| | - Ming Zhao
- Department of Engineering Mechanics, Dalian University of Technology, No. 2 Linggong Road, Dalian 116024, China; (Y.W.); (Y.L.); (M.Z.)
| | - Sergei Bosiakov
- Faculty of Mechanics and Mathematics, Belarusian State University, No. 4 Nezavisimosti Avenue, 220030 Minsk, Belarus;
| | - Lei Li
- Department of Vascular Surgery, The Second Affiliated Hospital of Dalian Medical University, No. 467 Zhongshan Road, Dalian 116023, China
- Correspondence:
| |
Collapse
|
5
|
Kozior T, Bochnia J, Gogolewski D, Zmarzły P, Rudnik M, Szot W, Szczygieł P, Musiałek M. Analysis of Metrological Quality and Mechanical Properties of Models Manufactured with Photo-Curing PolyJet Matrix Technology for Medical Applications. Polymers (Basel) 2022; 14:408. [PMID: 35160399 PMCID: PMC8839167 DOI: 10.3390/polym14030408] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Revised: 01/12/2022] [Accepted: 01/17/2022] [Indexed: 12/19/2022] Open
Abstract
This paper presents the metrological quality and mechanical properties of models in the form of hook holders manufactured from MED610 polymer material using PolyJet Matrix (PJM) technology. Measurements in the dimensional and shape analysis were made using the optical method with a microscope. The mechanical test was estimated by static tensile testing of the fabricated parts. A comprehensive approach to both the analysis of test results based on standardized samples and real hook models makes the presented results of great scientific and engineering value and creates the possibility of practical use in the medical industry, which has not been so comprehensively presented in the currently published research papers. Analyzing the results of measurements of the geometrical characteristics of the elements, it can be concluded that the PolyJet Matrix 3D printing technology has demonstrated a high level of precision in manufacturing the prototype parts. The static tensile test of samples, taking into account the printing directions, showed a high anisotropy of mechanical properties. The results of both strength and simulation tests indicate that it is necessary to assume a relatively high safety factor, the value of which depends on the direction of printing, which, in the case of such a responsible medical application, is very important.
Collapse
Affiliation(s)
- Tomasz Kozior
- Faculty of Mechatronics and Mechanical Engineering, Kielce University of Technology, 25-314 Kielce, Poland; (J.B.); (D.G.); (P.Z.); (M.R.); (W.S.); (P.S.); (M.M.)
| | | | | | | | | | | | | | | |
Collapse
|
6
|
Zhang X, Wang T, Xiao X, Li X, Wang CY, Huang B, He L, Song Y. Radiotherapy for head and neck tumours using an oral fixation and parameter acquisition device and TOMO technology: a randomised controlled study. BMJ Open 2021; 11:e052542. [PMID: 34772753 PMCID: PMC8593711 DOI: 10.1136/bmjopen-2021-052542] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/21/2021] [Accepted: 10/19/2021] [Indexed: 11/08/2022] Open
Abstract
INTRODUCTION Radiotherapy has become one of the main methods used for the treatment of malignant tumours of the head and neck. Spiral tomographic intensity-modulated radiotherapy has the many advantages of precision radiotherapy, which puts forward high requirements for postural reproducibility and accuracy. We will aim to ensure that the accurate positioning of the tumour will reduce the side effects of radiotherapy caused by positioning errors. We will design and implement this clinical trial using the patent of 'a radiotherapy oral fixation and parameter acquisition device (patent number: ZL201921877986.5)'. METHODS AND ANALYSIS This will be a randomised, controlled, prospective study with 120 patients with head and neck tumours. Using the random number table method, a random number sequence will be generated, and the patients will be enrolled in the experimental group (oral fixation device) and the control group (conventional fixation) in a 2:1 ratio. The primary outcome will be the progression-free survival time after the treatment. Secondary outcomes will include the oral mucosal reaction and the quality of life. Follow-ups will be carried out according to the plan. This is V.1.0 of protocol on 1 April 2021. The recruitment process for this clinical trial commenced on 1 May 2021, and will end on 1 October 2022. ETHICS AND DISSEMINATION The trial received ethical approval from Medical Ethics Committee of Liaoning Provincial Cancer Hospital (number 20210131X). The final results will be presented at a scientific conference and published in a peer-reviewed journal in accordance with the journal's guidelines. TRIAL REGISTRATION NUMBER ChiCTR2100045096.
Collapse
Affiliation(s)
- Xiaofang Zhang
- Department of Radiotherapy, Cancer Hospital of China Medical University, Shenyang, Liaoning, China
| | - Tianlu Wang
- Department of Radiotherapy, Cancer Hospital of China Medical University, Shenyang, Liaoning, China
| | - Xinyan Xiao
- China Medical University, Cancer Hospital of China Medical University, Shenyang, Liaoning, China
| | - Xia Li
- Department of Radiotherapy, Cancer Hospital of China Medical University, Shenyang, Liaoning, China
| | - Chen Yu Wang
- Department of Information Management, Cancer Hospital of China Medical University, Shenyang, Liaoning, China
| | - Bo Huang
- Department of Pathology, Cancer Hospital of China Medical University, Shenyang, Liaoning, China
| | - Lei He
- Department of Radiotherapy Physics, Cancer Hospital of China Medical University, Shenyang, Liaoning, China
| | - Yingqiu Song
- Department of Radiotherapy, Cancer Hospital of China Medical University, Shenyang, Liaoning, China
| |
Collapse
|
7
|
Gülcan O, Günaydın K, Tamer A. The State of the Art of Material Jetting-A Critical Review. Polymers (Basel) 2021; 13:2829. [PMID: 34451366 PMCID: PMC8399222 DOI: 10.3390/polym13162829] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2021] [Revised: 08/09/2021] [Accepted: 08/13/2021] [Indexed: 01/20/2023] Open
Abstract
Material jetting (MJ) technology is an additive manufacturing method that selectively cures liquid photopolymer to build functional parts. The use of MJ technology has increased in popularity and been adapted by different industries, ranging from biomedicine and dentistry to manufacturing and aviation, thanks to its advantages in printing parts with high dimensional accuracy and low surface roughness. To better understand the MJ technology, it is essential to address the capabilities, applications and the usage areas of MJ. Additionally, the comparison of MJ with alternative methods and its limitations need to be explained. Moreover, the parameters influencing the dimensional accuracy and mechanical properties of MJ printed parts should be stated. This paper aims to review these critical aspects of MJ manufacturing altogether to provide an overall insight into the state of the art of MJ.
Collapse
Affiliation(s)
- Orhan Gülcan
- General Electric Aviation, Gebze 41400, Kocaeli, Turkey
| | | | - Aykut Tamer
- Department of Mechanical Engineering, Imperial College London, London SW7 2AZ, UK;
| |
Collapse
|
8
|
Membrive Conejo I, Pera Cegarra O, Foro Arnalot P, Reig Castillejo A, Rodríguez de Dios N, Sanz Latiesas X, Pujol Vallverdú RM, Quera Jordana J, Fernandez-Velilla Cepria E, Algara Muñoz V, Algara López M. Custom 3D-printed applicators for high dose-rate brachytherapy in skin cancer. Brachytherapy 2021; 20:1257-1264. [PMID: 34384694 DOI: 10.1016/j.brachy.2021.05.164] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2020] [Revised: 05/20/2021] [Accepted: 05/27/2021] [Indexed: 11/28/2022]
Abstract
PURPOSE This paper describes the protocol for the development of 3D-printed custom applicators in treating skin carcinoma, the evaluation of the materials used, and the methods for segmentation and rendering of the applicators. MATERIAL AND METHODS The segmentation and rendering process for the applicator had six phases: (i) determination of the volume of the lesion using a computed tomography (CT) scan; (ii) delineation of the patient surface, using the same CT images; (iii) creation of the applicator in the planner and segmentation of the mold; (iv) preliminary dosimetry and establishment of the route of the catheter from the brachytherapy unit; (v) creation of the 3D applicator using specialized software; and (vi) applicator printing. Following this process, the patient returned for a second CT to undergo the definitive dosimetry with the applicator in place. Radiation therapy was then administered. RESULTS We made a total of 16 applicators. Only three applicators had to be remade, two due to an error in the infill and the other due to incorrect catheter geometry. In all cases, correct coverage of the planning target volume was achieved with the prescribed isodose. CONCLUSIONS The creation of custom molds in plesiotherapy for skin cancer with 3D printing is feasible. Compared to manual methods, 3D printing increases precision in applicator geometry and optimization of the dosimetry.
Collapse
Affiliation(s)
- Ismael Membrive Conejo
- Radiation Oncology Department, Hospital del Mar, Parc de Salut Mar, Barcelona, Spain; Institut Hospital del Mar d'Investigacions Mèdiques Barcelona, Spain.
| | - Oscar Pera Cegarra
- Radiation Oncology Department, Hospital del Mar, Parc de Salut Mar, Barcelona, Spain; Institut Hospital del Mar d'Investigacions Mèdiques Barcelona, Spain
| | - Palmira Foro Arnalot
- Radiation Oncology Department, Hospital del Mar, Parc de Salut Mar, Barcelona, Spain; Institut Hospital del Mar d'Investigacions Mèdiques Barcelona, Spain; Pompeu Fabra University, Barcelona, Spain
| | - Ana Reig Castillejo
- Radiation Oncology Department, Hospital del Mar, Parc de Salut Mar, Barcelona, Spain; Institut Hospital del Mar d'Investigacions Mèdiques Barcelona, Spain
| | - Nuria Rodríguez de Dios
- Radiation Oncology Department, Hospital del Mar, Parc de Salut Mar, Barcelona, Spain; Institut Hospital del Mar d'Investigacions Mèdiques Barcelona, Spain; Pompeu Fabra University, Barcelona, Spain
| | - Xavier Sanz Latiesas
- Radiation Oncology Department, Hospital del Mar, Parc de Salut Mar, Barcelona, Spain; Institut Hospital del Mar d'Investigacions Mèdiques Barcelona, Spain; Pompeu Fabra University, Barcelona, Spain
| | - Ramón M Pujol Vallverdú
- Institut Hospital del Mar d'Investigacions Mèdiques Barcelona, Spain; Dermatology Department, Hospital del Mar, Parc de Salut Mar, Barcelona, Spain; Universitat Autónoma de Barcelona Barcelona, Spain
| | - Jaume Quera Jordana
- Radiation Oncology Department, Hospital del Mar, Parc de Salut Mar, Barcelona, Spain; Institut Hospital del Mar d'Investigacions Mèdiques Barcelona, Spain; Pompeu Fabra University, Barcelona, Spain
| | - Enric Fernandez-Velilla Cepria
- Radiation Oncology Department, Hospital del Mar, Parc de Salut Mar, Barcelona, Spain; Institut Hospital del Mar d'Investigacions Mèdiques Barcelona, Spain
| | | | - Manuel Algara López
- Radiation Oncology Department, Hospital del Mar, Parc de Salut Mar, Barcelona, Spain; Institut Hospital del Mar d'Investigacions Mèdiques Barcelona, Spain; Universitat Autónoma de Barcelona Barcelona, Spain
| |
Collapse
|
9
|
Pugalendhi A, Ranganathan R. A review of additive manufacturing applications in ophthalmology. Proc Inst Mech Eng H 2021; 235:1146-1162. [PMID: 34176362 DOI: 10.1177/09544119211028069] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
Additive Manufacturing (AM) capabilities in terms of product customization, manufacture of complex shape, minimal time, and low volume production those are very well suited for medical implants and biological models. AM technology permits the fabrication of physical object based on the 3D CAD model through layer by layer manufacturing method. AM use Magnetic Resonance Image (MRI), Computed Tomography (CT), and 3D scanning images and these data are converted into surface tessellation language (STL) file for fabrication. The applications of AM in ophthalmology includes diagnosis and treatment planning, customized prosthesis, implants, surgical practice/simulation, pre-operative surgical planning, fabrication of assistive tools, surgical tools, and instruments. In this article, development of AM technology in ophthalmology and its potential applications is reviewed. The aim of this study is nurturing an awareness of the engineers and ophthalmologists to enhance the ophthalmic devices and instruments. Here some of the 3D printed case examples of functional prototype and concept prototypes are carried out to understand the capabilities of this technology. This research paper explores the possibility of AM technology that can be successfully executed in the ophthalmology field for developing innovative products. This novel technique is used toward improving the quality of treatment and surgical skills by customization and pre-operative treatment planning which are more promising factors.
Collapse
Affiliation(s)
- Arivazhagan Pugalendhi
- Department of Mechanical Engineering, Coimbatore Institute of Technology, Coimbatore, Tamil Nadu, India
| | - Rajesh Ranganathan
- Department of Mechanical Engineering, Coimbatore Institute of Technology, Coimbatore, Tamil Nadu, India
| |
Collapse
|
10
|
Herpel C, Schwindling FS, Held T, Christ L, Lang K, Schwindling M, Moratin J, Zaoui K, Moutsis T, Plinkert P, Herfarth K, Freudlsperger C, Rammelsberg P, Debus J, Adeberg S. Individualized 3D-Printed Tissue Retraction Devices for Head and Neck Radiotherapy. Front Oncol 2021; 11:628743. [PMID: 33833988 PMCID: PMC8021903 DOI: 10.3389/fonc.2021.628743] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2020] [Accepted: 01/11/2021] [Indexed: 11/25/2022] Open
Abstract
Background Radiotherapy for head and neck cancer may cause various oral sequelae, such as radiation-induced mucositis. To protect healthy tissue from irradiation, intraoral devices can be used. Current tissue retraction devices (TRDs) have to be either individually manufactured at considerable cost and time expenditure or they are limited in their variability. In this context, a 3D-printed, tooth-borne TRD might further facilitate clinical use. Methods A novel approach for the manufacturing of TRDs is described and its clinical application is analysed retrospectively. The devices were virtually designed for fabrication by 3D-printing technology, enabling—in only a single printing design—caudal or bi-lateral tongue displacement, as well as stabilization of a tongue-out position. For a total of 10 patients undergoing radiotherapy of head and neck tumors, the devices were individually adapted after pre-fabrication. Technical and clinical feasibility was assessed along with patient adherence. Tissue spacing was calculated by volumetric analysis of tongue retraction. In one exemplary case, radiotherapy treatment plans before and after tissue displacement were generated and compared. The reproducibility of maxillomandibular relation at device re-positioning was quantified by repeated intraoral optical scanning in a voluntary participant. Results 3D-printing was useful for the simplification of TRD manufacture, resulting in a total patient treatment time of less than 30 min. The devices were tolerated well by all tested patients over the entire radiation treatment period. No technical complications occurred with the devices. The TRDs caused an effective spacing of the healthy adjacent tissue, e.g., the tongue. Position changes of maxillomandibular relation were limited to a mean value of 98.1 µm ± 29.4 µm root mean square deviation between initial reference and follow-up positions. Conclusions The presented method allows a resource-efficient fabrication of individualized, tooth-bourne TRDs. A high reproducibility of maxillomandibular relation was found and the first clinical experiences underline the high potential of such devices for radiotherapy in the head and neck area.
Collapse
Affiliation(s)
- Christopher Herpel
- Department of Prosthetic Dentistry, Heidelberg University Hospital, Heidelberg, Germany
| | | | - Thomas Held
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), University Hospital Heidelberg, Heidelberg, Germany.,National Center for Tumor Diseases (NCT), University Hospital Heidelberg, Heidelberg, Germany
| | - Leo Christ
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
| | - Kristin Lang
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), University Hospital Heidelberg, Heidelberg, Germany.,National Center for Tumor Diseases (NCT), University Hospital Heidelberg, Heidelberg, Germany
| | | | - Julius Moratin
- Department of Oral and Maxillofacial Surgery, Heidelberg University Hospital, Heidelberg, Germany
| | - Karim Zaoui
- Department of Otorhinolaryngology, University of Heidelberg, Heidelberg, Germany
| | - Tracy Moutsis
- Department of Otorhinolaryngology, University of Heidelberg, Heidelberg, Germany
| | - Peter Plinkert
- Department of Otorhinolaryngology, University of Heidelberg, Heidelberg, Germany
| | - Klaus Herfarth
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), University Hospital Heidelberg, Heidelberg, Germany.,National Center for Tumor Diseases (NCT), University Hospital Heidelberg, Heidelberg, Germany.,Heidelberg Ion-Beam Therapy Center (HIT), University Hospital Heidelberg, Heidelberg, Germany
| | - Christian Freudlsperger
- Department of Oral and Maxillofacial Surgery, Heidelberg University Hospital, Heidelberg, Germany
| | - Peter Rammelsberg
- Department of Prosthetic Dentistry, Heidelberg University Hospital, Heidelberg, Germany
| | - Jürgen Debus
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), University Hospital Heidelberg, Heidelberg, Germany.,National Center for Tumor Diseases (NCT), University Hospital Heidelberg, Heidelberg, Germany.,Heidelberg Ion-Beam Therapy Center (HIT), University Hospital Heidelberg, Heidelberg, Germany.,Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany.,German Cancer Consortium (DKTK), partner site Heidelberg, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Sebastian Adeberg
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), University Hospital Heidelberg, Heidelberg, Germany.,National Center for Tumor Diseases (NCT), University Hospital Heidelberg, Heidelberg, Germany.,Heidelberg Ion-Beam Therapy Center (HIT), University Hospital Heidelberg, Heidelberg, Germany.,Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany.,German Cancer Consortium (DKTK), partner site Heidelberg, German Cancer Research Center (DKFZ), Heidelberg, Germany
| |
Collapse
|
11
|
Saleh Alghamdi S, John S, Roy Choudhury N, Dutta NK. Additive Manufacturing of Polymer Materials: Progress, Promise and Challenges. Polymers (Basel) 2021; 13:753. [PMID: 33670934 PMCID: PMC7957542 DOI: 10.3390/polym13050753] [Citation(s) in RCA: 71] [Impact Index Per Article: 17.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2021] [Revised: 02/24/2021] [Accepted: 02/25/2021] [Indexed: 12/21/2022] Open
Abstract
The use of additive manufacturing (AM) has moved well beyond prototyping and has been established as a highly versatile manufacturing method with demonstrated potential to completely transform traditional manufacturing in the future. In this paper, a comprehensive review and critical analyses of the recent advances and achievements in the field of different AM processes for polymers, their composites and nanocomposites, elastomers and multi materials, shape memory polymers and thermo-responsive materials are presented. Moreover, their applications in different fields such as bio-medical, electronics, textiles, and aerospace industries are also discussed. We conclude the article with an account of further research needs and future perspectives of AM process with polymeric materials.
Collapse
Affiliation(s)
- Saad Saleh Alghamdi
- School of Engineering, Chemical and Environmental Engineering, RMIT University, Melbourne 3000, Australia
| | - Sabu John
- School of Engineering, Manufacturing, Materials and Mechatronics, RMIT University, Bundoora 3083, Australia
| | - Namita Roy Choudhury
- School of Engineering, Chemical and Environmental Engineering, RMIT University, Melbourne 3000, Australia
| | - Naba K Dutta
- School of Engineering, Chemical and Environmental Engineering, RMIT University, Melbourne 3000, Australia
| |
Collapse
|
12
|
Ju SG, Ahn YC, Kim YB, Park SG, Choi YM, Na CH, Hong CS, Oh D, Kwon DY, Kim CC, Kim DH. Development of a Tongue Immobilization Device Using a 3D Printer for Intensity Modulated Radiation Therapy of Nasopharyngeal Cancer Patients. Cancer Res Treat 2020; 53:45-54. [PMID: 32972044 PMCID: PMC7812000 DOI: 10.4143/crt.2020.572] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2020] [Accepted: 09/14/2020] [Indexed: 11/22/2022] Open
Abstract
Purpose This study aimed to reduce radiation doses to the tongue, a patient-specific semi-customized tongue immobilization device (SCTID) was developed using a 3D printer for helical tomotherapy (HT) of nasopharyngeal cancer (NPCa). Dosimetric characteristics and setup stability of the SCTID were compared with those of a standard mouthpiece (SMP). Materials and Methods For displacement and robust immobilization of the tongue, the SCTID consists of four parts: upper and lower tooth stoppers, tongue guider, tongue-tip position guide bar, and connectors. With the SCTID and SMP, two sets of planning computed tomography and HT plans were obtained for 10 NPCa patients. Dosimetric and geometric characteristics were compared. Position reproducibility of the tongue with SCTID was evaluated by comparing with planned dose and adaptive accumulated dose of the tongue and base of the tongue based on daily setup mega-voltage computed tomography. Results Using the SCTID, the tongue was effectively displaced from the planning target volume compared to the SMP. The median mucosa of the tongue (M-tongue) dose was significantly reduced (20.7 Gy vs. 27.8 Gy). The volumes of the M-tongue receiving a dose of 15 Gy, 30 Gy, and 45 Gy and the volumes of the mucosa of oral cavity and oropharynx (M-OC/OP) receiving a dose of 45 Gy and 60 Gy were significantly lower than using the SMP. No significant differences was observed between the planned dose and the accumulated adaptive dose in any dosimetric characteristics of the tongue and base of tongue. Conclusion SCTID can not only reduce the dose to the M-tongue and M-OC/OP dramatically, when compared to SMP, but also provide excellent reproducibility and easy visual verification.
Collapse
Affiliation(s)
- Sang Gyu Ju
- Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Yong Chan Ahn
- Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.,Department of Medical Device Management and Research, Samsung Advanced Institute for Health Science & Technology, Sungkyunkwan University, Seoul, Korea
| | - Yeong-Bi Kim
- Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Seung Gyu Park
- Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Yoo-Mi Choi
- Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.,Department of Medical Device Management and Research, Samsung Advanced Institute for Health Science & Technology, Sungkyunkwan University, Seoul, Korea
| | - Cho Hee Na
- Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.,Department of Medical Device Management and Research, Samsung Advanced Institute for Health Science & Technology, Sungkyunkwan University, Seoul, Korea
| | - Chae-Seon Hong
- Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, Korea
| | - Dongryul Oh
- Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Dong Yeol Kwon
- Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Cheol Chong Kim
- Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Dong Hyeon Kim
- Institute of Advanced Convergence Technology, Kyungpook National University, Daegu, Korea
| |
Collapse
|
13
|
Three-Dimensional Printed Silicone Bite Blocks for Radiotherapy of Head and Neck Cancer—A Preliminary Study. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10051688] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Conventional methods that have been developed to immobilize the mouth and tongue for radiotherapy (RT) in head and neck cancer (HNC) treatment have been unsatisfactory. We, therefore, developed three-dimensional (3D), customizable, silicone bite blocks and examined their clinical feasibility. For HNC patients, before RT, the 3D printed bite blocks were fabricated based on primary computed tomography (CT) simulation images. The placement of the 3D bite blocks was followed by a secondary CT simulation before RT planning was finalized. Dosimetric parameters and positioning verification achieved with the propose bite blocks were compared with conventional universal oral corks. The 3D printed bite blocks were conformal to the occlusal surface, ensuring immobilization of the tongue without eliciting a gag reflex, and an elastic and firm texture that supports opening of the mouth, with a smooth surface with tolerable intraoral tactility. The dosimetry of patients using the proposed bite blocks showed better coverage of the planning target volume and surface of a tumour bed along with reduction in normal tissue doses. Good concordance of positioning by 3D printed bite blocks during the RT course was verified. The 3D printed bite blocks with silicone might be a customizable, safe, and practical advanced technology in RT for HNC.
Collapse
|
14
|
Kadoya N, Abe K, Nemoto H, Sato K, Ieko Y, Ito K, Dobashi S, Takeda K, Jingu K. Evaluation of a 3D-printed heterogeneous anthropomorphic head and neck phantom for patient-specific quality assurance in intensity-modulated radiation therapy. Radiol Phys Technol 2019; 12:351-356. [PMID: 31364005 DOI: 10.1007/s12194-019-00527-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2019] [Revised: 07/21/2019] [Accepted: 07/22/2019] [Indexed: 11/28/2022]
Abstract
We evaluated an anthropomorphic head and neck phantom with tissue heterogeneity, produced using a personal 3D printer, with quality assurance (QA), specific to patients undergoing intensity-modulated radiation therapy (IMRT). Using semi-automatic segmentation, 3D models of bone, soft tissue, and an air-filled cavity were created based on computed tomography (CT) images from patients with head and neck cancer treated with IMRT. For the 3D printer settings, polylactide was used for soft tissue with 100% infill. Bone was reproduced by pouring plaster into the cavity created by the 3D printer. The average CT values for soft tissue and bone were 13.0 ± 144.3 HU and 439.5 ± 137.0 HU, respectively, for the phantom and 12.1 ± 124.5 HU and 771.5 ± 405.3 HU, respectively, for the patient. The gamma passing rate (3%/3 mm) was 96.1% for a nine-field IMRT plan. Thus, this phantom may be used instead of a standard shape phantom for patient-specific QA in IMRT.
Collapse
Affiliation(s)
- Noriyuki Kadoya
- Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan.
| | - Kota Abe
- Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan.,Department of Radiation Oncology, Tokyo Metropolitan Cancer and Infectious Diseases Center Komagome Hospital, Tokyo, 113-8677, Japan
| | - Hikaru Nemoto
- Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Kiyokazu Sato
- Department of Radiology, Tohoku University Hospital, Sendai, Miyagi, 980-8574, Japan
| | - Yoshiro Ieko
- Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan.,Department of Radiation Oncology, Yamagata University Faculty of Medicine, Yamagata, Japan
| | - Kengo Ito
- Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Suguru Dobashi
- Department of Radiological Technology, School of Health Sciences, Faculty of Medicine, Tohoku University, Miyagi, 980-8574, Japan
| | - Ken Takeda
- Department of Radiological Technology, School of Health Sciences, Faculty of Medicine, Tohoku University, Miyagi, 980-8574, Japan
| | - Keiichi Jingu
- Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| |
Collapse
|