1
|
Rizzarelli P, Leanza M, Rapisarda M. Investigations into the characterization, degradation, and applications of biodegradable polymers by mass spectrometry. MASS SPECTROMETRY REVIEWS 2023. [PMID: 38014928 DOI: 10.1002/mas.21869] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Revised: 10/10/2023] [Accepted: 11/08/2023] [Indexed: 11/29/2023]
Abstract
Biodegradable polymers have been getting more and more attention because of their contribution to the plastic pollution environmental issues and to move towards a circular economy. Nevertheless, biodegradable materials still exhibit various disadvantages restraining a widespread use in the market. Therefore, additional research efforts are required to improve their performance. Mass spectrometry (MS) affords a relevant contribution to optimize biodegradable polymer synthesis, to confirm macromolecular structures, to examine along the time the progress of degradation processes and highlight advantages and drawbacks in the extensive applications. This review aims to provide an overview of the MS investigations carried out to support the synthesis of biodegradable polymers, with helpful information on undesirable products or polymerization mechanism, to understand deterioration pathways by the structure of degradation products and to follow drug release and pharmacokinetic. Additionally, it summarizes MS studies addressed on environmental and health issues related to the extensive use of plastic materials, that is, potential migration of additives or microplastics identification and quantification. The paper is focused on the most significant studies relating to synthetic and microbial biodegradable polymers published in the last 15 years, not including agro-polymers such as proteins and polysaccharides.
Collapse
Affiliation(s)
- Paola Rizzarelli
- Consiglio Nazionale delle Ricerche (CNR), Istituto per i Polimeri Compositi e Biomateriali (IPCB), ede Secondaria di Catania, Catania, Italy
| | - Melania Leanza
- Consiglio Nazionale delle Ricerche (CNR), Istituto per i Polimeri Compositi e Biomateriali (IPCB), ede Secondaria di Catania, Catania, Italy
| | - Marco Rapisarda
- Consiglio Nazionale delle Ricerche (CNR), Istituto per i Polimeri Compositi e Biomateriali (IPCB), ede Secondaria di Catania, Catania, Italy
| |
Collapse
|
2
|
Esakkimuthu S, Wang S, Abomohra AEF. CO2-Mediated Energy Conversion and Recycling. WASTE-TO-ENERGY 2022:379-409. [DOI: 10.1007/978-3-030-91570-4_13] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
|
3
|
Arafat M, Song Y, Brewer K, Fouladian P, Parikh A, Albrecht H, Blencowe A, Garg S. Pharmaceutical Development of 5-Fluorouracil-Eluting Stents for the Potential Treatment of Gastrointestinal Cancers and Related Obstructions. Drug Des Devel Ther 2021; 15:1495-1507. [PMID: 33859473 PMCID: PMC8043784 DOI: 10.2147/dddt.s299401] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2020] [Accepted: 03/23/2021] [Indexed: 12/15/2022] Open
Abstract
BACKGROUND Drug-eluting gastrointestinal (GI) stents are emerging as promising platforms for the treatment of GI cancers and provide the combined advantages of mechanical support to prevent lumen occlusion and as a reservoir for localized drug delivery to tumors. Therefore, in this work we present a detailed quality assurance study of 5-fluorouracil (5FU) drug-eluting stents (DESs) as potential candidates for the treatment of obstructive GI cancers. METHODS The 5FU DESs were fabricated via a simple two-step sequential dip-coating process of commercial GI self-expanding nitinol stents with a 5FU-loaded polyurethane basecoat and a drug-free protective poly(ethylene-co-vinyl acetate) topcoat. The drug loading, content uniformity and drug stability were determined using a validated high-performance liquid chromatography (HPLC) method, which is also recommended in the United States Pharmacopeia. In vitro drug release studies were performed in phosphate buffered saline to determine the drug releasing properties of the two 5FU-loaded stents. Gas chromatography (GC) and HPLC were employed to determine total residual tetrahydrofuran and N,N-dimethylformamide in the stents remaining from the manufacturing process. Sterilization of the stents was performed using gamma radiation and stability testing was carried out for 3 months. RESULTS The drug loading analysis revealed excellent uniformity in the distribution of 5FU between and within individual stents. Determination of drug stability in the biorelevant release media confirmed that 5FU remains stable over 100 d. In vitro drug release studies from the stents revealed sustained release of 5FU across two different time scales (161 and 30 d), and mathematical modeling of drug release profiles revealed a diffusion-controlled mechanism for the sustained 5FU release. GC and HPLC analysis revealed that the daily residual solvent leached from the stents was below the United States (US) Food and Drug Administration (FDA) guidelines, and therefore, unlikely to cause localized/systemic toxicities. Sterilization of the stents with gamma radiation and accelerated stability tests over a period of 3 months revealed no significant effect on the stability or in vitro release of 5FU. CONCLUSION Our results demonstrate that the 5FU DESs meet relevant quality standards and display favourable drug release characteristics for the potential treatment of GI cancers and related obstructions.
Collapse
Affiliation(s)
- Mohammad Arafat
- Pharmaceutical Innovation and Development (PIDG) Group, Clinical and Health Sciences, University of South Australia, Adelaide, SA, 5000, Australia
| | - Yunmei Song
- Pharmaceutical Innovation and Development (PIDG) Group, Clinical and Health Sciences, University of South Australia, Adelaide, SA, 5000, Australia
| | - Kyle Brewer
- Applied Chemistry and Translational Biomaterials (ACTB) Group, Clinical and Health Sciences, University of South Australia, Adelaide, SA, 5000, Australia
| | - Paris Fouladian
- Pharmaceutical Innovation and Development (PIDG) Group, Clinical and Health Sciences, University of South Australia, Adelaide, SA, 5000, Australia
| | - Ankit Parikh
- Pharmaceutical Innovation and Development (PIDG) Group, Clinical and Health Sciences, University of South Australia, Adelaide, SA, 5000, Australia
| | - Hugo Albrecht
- Drug Discovery and Development Group, Clinical and Health Sciences, University of South Australia, Adelaide, SA, 5000, Australia
| | - Anton Blencowe
- Applied Chemistry and Translational Biomaterials (ACTB) Group, Clinical and Health Sciences, University of South Australia, Adelaide, SA, 5000, Australia
| | - Sanjay Garg
- Pharmaceutical Innovation and Development (PIDG) Group, Clinical and Health Sciences, University of South Australia, Adelaide, SA, 5000, Australia
| |
Collapse
|
4
|
Development and In Vitro Evaluation of 5-Fluorouracil-Eluting Stents for the Treatment of Colorectal Cancer and Cancer-Related Obstruction. Pharmaceutics 2020; 13:pharmaceutics13010017. [PMID: 33374233 PMCID: PMC7823773 DOI: 10.3390/pharmaceutics13010017] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Revised: 12/17/2020] [Accepted: 12/19/2020] [Indexed: 02/06/2023] Open
Abstract
Self-expanding metal stents (SEMSs) are currently the gold standard for the localised management of malignant gastrointestinal (GI) stenosis and/or obstructions. Despite encouraging clinical success, in-stent restenosis caused by tumour growth is a significant challenge. Incorporating chemotherapeutic drugs into GI stents is an emerging strategy to provide localised and sustained release of drugs to intestinal malignant tissues to prevent tumour growth. Therefore, the aim of this work was to develop and evaluate a local GI stent-based delivery system that provides a controlled release of 5-fluorouracil (5FU) over a course of several weeks to months, for the treatment of colorectal cancer and cancer-related stenosis/obstructions. The 5FU-loaded GI stents were fabricated via sequential dip-coating of commercial GI stents with a drug-loaded polyurethane (PU) basecoat and a drug-free poly(ethylene-co-vinyl acetate) (PEVA) topcoat. For comparison, two types of commercial stents were investigated, including bare and silicone (Si) membrane-covered stents. The physicochemical properties of the 5FU-loaded stents were evaluated using photoacoustic Fourier-transform infrared (PA-FTIR) spectroscopy, X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), and thermal analysis. In vitro release studies in biological medium revealed that the 5FU-loaded stents provided a sustained release of drug over the period studied (18 d), and cell viability, cell cycle distribution and apoptosis assays showed that the released 5FU had comparable anticancer activity against human colon cancer cells (HCT-116) to pure 5FU. This study demonstrates that dip-coating is a facile and reliable approach for fabricating drug-eluting stents (DESs) that are promising candidates for the treatment of GI obstructions and/or restenosis.
Collapse
|
5
|
Xiang Y, Wang W, Gao Y, Zhang J, Zhang J, Bai Z, Zhang S, Yang Y. Production and Characterization of an Integrated Multi-Layer 3D Printed PLGA/GelMA Scaffold Aimed for Bile Duct Restoration and Detection. Front Bioeng Biotechnol 2020; 8:971. [PMID: 32984274 PMCID: PMC7479063 DOI: 10.3389/fbioe.2020.00971] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2020] [Accepted: 07/27/2020] [Indexed: 11/28/2022] Open
Abstract
We successfully fabricated artificial bile duct via 3D printing technique which was composed of poly (lactic-co-glycolic acid) (PLGA) and gelatin methacrylate (GelMA). The PLGA-inner layer provided sufficient strength to support the bile duct contraction, the GelMA-outer layer possessed good biocompatibility to provide a good living environment for the cells. Moreover, IKVAV laminin peptide (Ile-Lys-Val-Ala-Val) and ultrasmall superparamagnetic iron oxide (USPIO) were used to regulate scaffold cell adhesion and magnetic resonance imaging (MRI) detection, respectively. After BMSCs co-culture with IKVAV at a certain concentration, the survival rate and adhesion of BMSCs was increased obviously. Meanwhile, the fabricated scaffold exhibited the tensile modulus in the range of 17.19 - 29.05 MPa and the compressive modulus in the range of 0.042 - 0.066 MPa, which could meet the needs of human implantation. In an animal experiment in vivo pig bile duct regeneration, PLGA/GelMA/IKVAV/USPIO duct conduits could promote bile duct regeneration and enhance cytokeratin 19 (CK19) expression. In summary, the composite bile duct scaffold with excellent MRI imaging function and biocompatibility could be used to develop bioactive artificial bile ducts.
Collapse
Affiliation(s)
- Yang Xiang
- Department of Hepatobiliary Surgery, Affiliated Haikou Hospital of Xiangya Medical College, Central South University, Haikou, China
- Department of Urology Surgery, Affiliated Haikou Hospital of Xiangya Medical College, Central South University, Haikou, China
| | - Weijia Wang
- School of Metallurgy and Environment, Central South University, Changsha, China
| | - Yuanhui Gao
- Central Laboratory, Affiliated Haikou Hospital of Xiangya Medical College, Central South University, Haikou, China
| | - Jianquan Zhang
- Department of Hepatobiliary Surgery, Affiliated Haikou Hospital of Xiangya Medical College, Central South University, Haikou, China
| | - Jing Zhang
- Department of Obstetrics and Gynecology, Affiliated Haikou Hospital of Xiangya Medical College, Central South University, Haikou, China
| | - Zhiming Bai
- Department of Urology Surgery, Affiliated Haikou Hospital of Xiangya Medical College, Central South University, Haikou, China
| | - Shufang Zhang
- Central Laboratory, Affiliated Haikou Hospital of Xiangya Medical College, Central South University, Haikou, China
| | - Yijun Yang
- Department of Hepatobiliary Surgery, Affiliated Haikou Hospital of Xiangya Medical College, Central South University, Haikou, China
| |
Collapse
|
6
|
Rizzarelli P, Rapisarda M, Valenti G. Mass spectrometry in bioresorbable polymer development, degradation and drug-release tracking. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2020; 34 Suppl 2:e8697. [PMID: 31834664 DOI: 10.1002/rcm.8697] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/07/2019] [Revised: 12/05/2019] [Accepted: 12/10/2019] [Indexed: 06/10/2023]
Abstract
A detailed characterization of polymeric matrices and appropriate degradation monitoring techniques are required to sustain the development of new materials as well as to enlarge the applications of the old ones. In fact, polymer analysis is essential for the clarification of the intrinsic relationship between structure and properties that ascertains the industrial applications in diverse fields. In bioresorbable and biodegradable polymers, the role of analytical methods is dual since it is pointed both at the polymeric matrices and at degradation tracking. The structural architectures, the mechanical and morphological properties, and the degradation rate, are of outstanding importance for a specific application. In some cases, the complexity of the polymer structure, the processes of decomposition or the low concentration of the degradation products need the concurrent use of different complementary analytical techniques to give detailed information of the reactions taking place. Several analytical methods are used in bioresorbable polymer development and degradation tracking. Among them, mass spectrometry (MS) plays an essential role and it is used to refine polymer syntheses, for its high sensitivity, to highlight degradation mechanism by detecting compounds present in trace amounts, or to track the degradation product profile and to study drug release. In fact, elucidation of reaction mechanisms and polymer structure, attesting to the purity and detecting defects as well as residual catalysts, in biodegradable and bioresorbable polymers, requires sensitive analytical characterization methods that are essential in providing an assurance of safety, efficacy and quality. This review aims to provide an overview of the MS strategies used to support research and development of resorbable polymers as well as to investigate their degradation mechanisms. It is focused on the most significant studies concerning synthetic bioresorbable matrices (polylactide, polyglycolide and their copolymers, polyhydroxybutyrate, etc.), published in the last ten years.
Collapse
Affiliation(s)
- Paola Rizzarelli
- Istituto per i Polimeri, Compositi e Biomateriali, Consiglio Nazionale delle Ricerche, Via P. Gaifami 18, Catania, 95126, Italy
| | - Marco Rapisarda
- Istituto per i Polimeri, Compositi e Biomateriali, Consiglio Nazionale delle Ricerche, Via P. Gaifami 18, Catania, 95126, Italy
| | - Graziella Valenti
- Istituto per i Polimeri, Compositi e Biomateriali, Consiglio Nazionale delle Ricerche, Via P. Gaifami 18, Catania, 95126, Italy
| |
Collapse
|
7
|
Beck-Broichsitter M. Stability of Polymer Coatings on Nebulizer Membranes During Aerosol Generation. J Pharm Sci 2019; 108:3750-3754. [PMID: 31473213 DOI: 10.1016/j.xphs.2019.08.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2019] [Revised: 08/12/2019] [Accepted: 08/22/2019] [Indexed: 10/26/2022]
Abstract
The dimensions of orifices found in aperture plates used for nebulization can be modified by thin polymer coatings with the aim to control the size distribution of the generated aerosol droplets. However, the stability of such polymer coatings on the surface of nebulizer membranes during aerosol generation has not been elucidated. Nebulizer membranes made of stainless steel were covered with a thin film of poly(chloro-p-xylylene) (~1 μm) in the presence or absence of a silane-based adhesion promoter. Thereby, the orifice cross-sections of the nebulizer membrane were reduced by ~50%, accompanied by a remarkable decline in droplet size. Upon continuous nebulization of aqueous test liquids, the droplet size generated by the nonconditioned (no silane), poly(chloro-p-xylylene)-coated membranes reverted to that of the uncoated nebulizer membrane within ~5 min. By contrast, no such rapid return of droplet size to "baseline" values was noticed for the silane-conditioned, poly(chloro-p-xylylene)-coated counterparts. Scanning electron microscopy exhibited significant polymer detachment from the orifices of the nonconditioned (no silane) membranes and thus confirmed the findings from laser diffraction. Overall, silane-based adhesion promoters can increase the persistence of poly(chloro-p-xylylene) coatings on nebulizer membranes during aerosol generation.
Collapse
Affiliation(s)
- Moritz Beck-Broichsitter
- Medical Clinic II, Department of Internal Medicine, Justus-Liebig-Universität, Klinikstr. 33, D-35392 Giessen, Germany.
| |
Collapse
|
8
|
Wentzlaff M, Senz V, Seidlitz A. Evaluation of the suitability of a fluidized bed process for the coating of drug-eluting stents. Eur J Pharm Biopharm 2019; 139:85-92. [PMID: 30878518 DOI: 10.1016/j.ejpb.2019.03.013] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2019] [Accepted: 03/11/2019] [Indexed: 12/11/2022]
Abstract
Drug-eluting stents are often coated using single-stent coating techniques. In pharmaceutical industry, single-tablet coating is unthinkable. Instead large batches of tablets are coated in fluidized bed apparatuses or pan coaters. Therefore, it was the aim of this work to evaluate whether stents can be coated using a fluidized bed process. For this purpose stents were coated with the model fluorescent drug triamterene embedded in ammonium methacrylate copolymer. Different stent lengths as well as different coating yields were assessed and also a drug-free topcoat was evaluated. The coated stents were analysed regarded coating layer mass, drug content, surface structure, coating thickness and drug release. Furthermore, coating yield and stent defect rate were examined. Except for one stent configuration good results were obtained without optimization of process parameters which indicates the suitability of the method to coat large amounts of stents simultaneously in principle. Drug release was tuneable over a wide range of time spans and a wide range of drug loadings was produced. Further work will be necessary to transform the results of this study from a model stent to a clinically relevant product.
Collapse
Affiliation(s)
- Monika Wentzlaff
- Institute of Pharmacy, Biopharmaceutics and Pharmaceutical Technology, Center of Drug Absorption and Transport (C_DAT), University of Greifswald, Felix-Hausdorff-Straße 3, 17487 Greifswald, Germany
| | - Volkmar Senz
- Institute for Biomedical Engineering, Rostock University Medical Center, Friedrich-Barnewitz-Straße 4, 18119 Rostock, Germany
| | - Anne Seidlitz
- Institute of Pharmacy, Biopharmaceutics and Pharmaceutical Technology, Center of Drug Absorption and Transport (C_DAT), University of Greifswald, Felix-Hausdorff-Straße 3, 17487 Greifswald, Germany.
| |
Collapse
|
9
|
Gryka MC, Comi TJ, Forsyth RA, Hadley PM, Deb S, Bhargava R. Controlled dissolution of freeform 3D printed carbohydrate glass scaffolds in hydrogels using a hydrophobic spray coating. ADDITIVE MANUFACTURING 2019; 26:193-201. [PMID: 30775269 PMCID: PMC6371974 DOI: 10.1016/j.addma.2018.12.014] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Freeform 3D printing combined with sacrificial molding promises to lead advances in production of highly complex tubular systems for biomedical applications. Here we leverage a purpose-built isomalt 3D printer to generate complex channel geometries in hydrogels which would be inaccessible with other techniques. To control the dissolution of the scaffold, we propose an enabling technology consisting of an automated nebulizer coating system which applies octadecane to isomalt scaffolds. Octadecane, a saturated hydrocarbon, protects the rigid mold from dissolution and provides ample time for gels to set around the sacrificial structure. With a simplified model of the nebulizer system, the robotic motion was optimized for uniform coating. Using a combination of stimulated Raman scattering (SRS) microscopy and X-ray computed tomography, the coating was characterized to assess surface roughness and consistency. Colorimetric measurements of dissolution rates allowed optimization of sprayer parameters, yielding a decrease in dissolution rates by at least 4 orders of magnitude. High fidelity channels are ensured by surfactant treatment of the coating, which prevents bubbles from clinging to the surface. Spontaneous Raman scattering microspectroscopy and white light microscopy indicate cleared channels are free of octadecane following gentle flushing. The capabilities of the workflow are highlighted with several complex channel architectures including helices, blind channels, and multiple independent channels within polyacrylamide hydrogels of varying stiffnesses.
Collapse
Affiliation(s)
- M C Gryka
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL
| | - T J Comi
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL
| | - R A Forsyth
- Department of Chemical Engineering, University of Illinois at Urbana-Champaign, Urbana, IL
| | - P M Hadley
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL
| | - S Deb
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL
| | - R Bhargava
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL
- Departments of Chemistry, Chemical and Biomolecular Engineering, Mechanical Science and Engineering, and Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL
| |
Collapse
|
10
|
Woolford SE, Tran M, NguyenPho A, McDermott MK, Oktem B, Wickramasekara S. Optimization of balloon coating process for paclitaxel coated balloons via micro-pipetting method. Int J Pharm 2019; 554:312-321. [PMID: 30395954 DOI: 10.1016/j.ijpharm.2018.11.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2018] [Revised: 10/30/2018] [Accepted: 11/02/2018] [Indexed: 10/27/2022]
Abstract
Drug coated balloons (DCBs) have proven to be a suitable alternative for the treatment of cardiovascular diseases. They allow for uniform delivery of an antiproliferative drug to the stenotic site without permanent implantation of the device in the patient's body. There are, however, regulatory concerns regarding the lack of data associated with variable drug delivery to the target site, which can be related to the coating process. This study describes the process for an in-house micro-pipetting coating method that incorporates a laboratory-developed coating equation for determining optimal coating parameters. The coating solutions included a common drug of choice, paclitaxel, along with a hydrophilic excipient, such as iopromide. It was found that using a revolution rate of 240 rev/min, a flow rate of 25 µL/min and a translational speed of 0.033 cm/s resulted in visually uniform coatings. High performance liquid chromatography (HPLC) allowed for the determination of paclitaxel content on the balloon surface. Scanning electron microscopy (SEM) enabled analysis of coating thickness and texture at distal, middle, and proximal positions on the balloon; average thicknesses were determined to be 16.4 ± 5.8, 14.8 ± 1.4, and 18.1 ± 3.9 µm, respectively. These optimized coating conditions have been confirmed by in vitro drug release kinetics studies. Overall this study generated a simple and reproducible micro-pipetting coating method for the sustained release of drugs from the drug coated balloons.
Collapse
Affiliation(s)
- Steven E Woolford
- Division of Biology, Chemistry, and Materials Science, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, MD 20993, United States
| | - Mandy Tran
- Division of Biology, Chemistry, and Materials Science, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, MD 20993, United States
| | - Agnes NguyenPho
- Division of Quality Surveillance Assessment, Office of Surveillance, Office of Pharmaceutical Quality, Center for Drug Evaluation and Research, US Food and Drug Administration, Silver Spring, MD 20993, United States
| | - Martin K McDermott
- Division of Biology, Chemistry, and Materials Science, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, MD 20993, United States
| | - Berk Oktem
- Division of Biology, Chemistry, and Materials Science, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, MD 20993, United States
| | - Samanthi Wickramasekara
- Division of Biology, Chemistry, and Materials Science, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, MD 20993, United States.
| |
Collapse
|
11
|
|
12
|
In vitro release study of sirolimus from a PDLLA matrix on a bioresorbable drug-eluting stent. J Drug Deliv Sci Technol 2018. [DOI: 10.1016/j.jddst.2018.08.026] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
13
|
Muthuraj R, Mekonnen T. Recent progress in carbon dioxide (CO2) as feedstock for sustainable materials development: Co-polymers and polymer blends. POLYMER 2018. [DOI: 10.1016/j.polymer.2018.04.078] [Citation(s) in RCA: 115] [Impact Index Per Article: 19.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
14
|
Synthesis and properties of CO2-based plastics: Environmentally-friendly, energy-saving and biomedical polymeric materials. Prog Polym Sci 2018. [DOI: 10.1016/j.progpolymsci.2018.01.006] [Citation(s) in RCA: 109] [Impact Index Per Article: 18.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
15
|
Application of paclitaxel as adjuvant treatment for benign cicatricial airway stenosis. ACTA ACUST UNITED AC 2016; 36:817-822. [PMID: 27924518 DOI: 10.1007/s11596-016-1668-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2016] [Revised: 08/22/2016] [Indexed: 10/18/2022]
Abstract
Benign cicatricial airway stenosis (BCAS) is a potentially life-threatening disease. Recurrence occurs frequently after endoscopic treatment. Paclitaxel is known to prevent restenosis, but its clinical efficacy and safety is undetermined. Therefore, in this study, we investigated the efficacy and associated complications of paclitaxel as adjuvant treatment for BCAS of different etiologies. The study cohort included 28 patients with BCAS resulting from tuberculosis, intubation, tracheotomy, and other etiologies. All patients were treated at the Department of Respiratory Diseases, Beijing Tian Tan Hospital, Capital Medical University, China, between January 2010 and August 2014. After primary treatment by balloon dilation, cryotherapy, and/or high-frequency needle-knife treatment, paclitaxel was applied to the airway mucosa at the site of stenosis using a newly developed local instillation catheter. The primary outcome measures were the therapeutic efficacy of paclitaxel as adjuvant treatment, and the incidence of complications was observed as well. According to our criteria for evaluating the clinical effects on BCAS, 24 of the 28 cases achieved durable remission, three cases had remission, and one case showed no remission. Thus, the durable remission rate was 85.7%, and the combined effective rate was 96.4%. No differences in outcomes were observed among the different BCAS etiologies (P=0.144), and few complications were observed. Our results indicated that paclitaxel as an adjuvant treatment has greater efficacy than previously reported BCAS treatment methods.
Collapse
|
16
|
Bohr A, Water JJ, Wang Y, Arnfast L, Beck-Broichsitter M. Potential of surface-eroding poly(ethylene carbonate) for drug delivery to macrophages. Int J Pharm 2016; 511:814-20. [DOI: 10.1016/j.ijpharm.2016.07.075] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2016] [Revised: 07/28/2016] [Accepted: 07/29/2016] [Indexed: 01/06/2023]
|
17
|
The use of polymer-based nanoparticles and nanostructured materials in treatment and diagnosis of cardiovascular diseases: Recent advances and emerging designs. Prog Polym Sci 2016. [DOI: 10.1016/j.progpolymsci.2016.01.002] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
18
|
Scoutaris N, Ross S, Douroumis D. Current Trends on Medical and Pharmaceutical Applications of Inkjet Printing Technology. Pharm Res 2016; 33:1799-816. [DOI: 10.1007/s11095-016-1931-3] [Citation(s) in RCA: 72] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2016] [Accepted: 04/21/2016] [Indexed: 11/27/2022]
|
19
|
McDermott M, Chatterjee S, Hu X, Ash-Shakoor A, Avery R, Belyaeva A, Cruz C, Hughes M, Leadbetter J, Merkle C, Moot T, Parvinian S, Patwardhan D, Saylor D, Tang N, Zhang T. Application of quality by design (QbD) approach to ultrasonic atomization spray coating of drug-eluting stents. AAPS PharmSciTech 2015; 16:811-23. [PMID: 25563817 DOI: 10.1208/s12249-014-0266-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2014] [Accepted: 12/08/2014] [Indexed: 11/30/2022] Open
Abstract
The drug coating process for coated drug-eluting stents (DES) has been identified as a key source of inter- and intra-batch variability in drug elution rates. Quality-by-design (QbD) principles were applied to gain an understanding of the ultrasonic spray coating process of DES. Statistically based design of experiments (DOE) were used to understand the relationship between ultrasonic atomization spray coating parameters and dependent variables such as coating mass ratio, roughness, drug solid state composite microstructure, and elution kinetics. Defect-free DES coatings composed of 70% 85:15 poly(DL-lactide-co-glycolide) and 30% everolimus were fabricated with a constant coating mass. The drug elution profile was characterized by a mathematical model describing biphasic release kinetics. Model coefficients were analyzed as a DOE response. Changes in ultrasonic coating processing conditions resulted in substantial changes in roughness and elution kinetics. Based on the outcome from the DOE study, a design space was defined in terms of the critical coating process parameters resulting in optimum coating roughness and drug elution. This QbD methodology can be useful to enhance the quality of coated DES.
Collapse
|
20
|
A Polymer-Free Paclitaxel Eluting Coronary Stent: Effects of Solvents, Drug Concentrations and Coating Methods. Ann Biomed Eng 2014; 42:1170-84. [DOI: 10.1007/s10439-014-1003-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2013] [Accepted: 03/28/2014] [Indexed: 10/25/2022]
|
21
|
Solvent induced phase inversion-based in situ forming controlled release drug delivery implants. J Control Release 2014; 176:8-23. [DOI: 10.1016/j.jconrel.2013.12.020] [Citation(s) in RCA: 75] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2013] [Revised: 12/17/2013] [Accepted: 12/19/2013] [Indexed: 01/04/2023]
|
22
|
Chu D, Curdy C, Riebesehl B, Zhang Y, Beck-Broichsitter M, Kissel T. Enzyme-responsive surface erosion of poly(ethylene carbonate) for controlled drug release. Eur J Pharm Biopharm 2013; 85:1232-7. [DOI: 10.1016/j.ejpb.2013.04.011] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2012] [Revised: 04/03/2013] [Accepted: 04/15/2013] [Indexed: 11/30/2022]
|
23
|
Amini-Fazl MS, Mobedi H, Barzin J. Investigation of aqueous stability of taxol in different release media. Drug Dev Ind Pharm 2013; 40:519-26. [PMID: 23594296 DOI: 10.3109/03639045.2013.771646] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
In the present study, the aqueous stability of taxol in different aqueous media and immiscible aqueous/organic systems at 37 °C was investigated. The aqueous media included phosphate buffered saline (PBS) and PBS containing 10% methanol, 10% ethanol, 10% hydroxypropyl β-cyclodextrin (HP-βCD), 1% sodium citrate and 1% Tween 80. The immiscible systems consisted of PBS/octanol, PBS/dichloromethane, PBS/chloroform and PBS/ethyl acetate. The concentrations of taxol and related derivatives in each of the media were determined through the high-performance liquid chromatography assay. Results showed that hydrolysis and epimerization were two major types of degradation for taxol in the aqueous media starting from the initial hours of contact (6 hours). Addition of Tween 80 to PBS moderately increased the aqueous stability of taxol. As well, using PBS containing 10% HP-βCD inhibited the taxol hydrolysis, while epimerization still in process. In the case of immiscible systems, except for PBS/ethyl acetate system, no evidences of taxol hydrolysis were observed. Meanwhile, epimerization of taxol in PBS/dichloromethane and PBS/chloroform systems underwent due to the ability of C-Cl bonds to form hydrogen bonding with the hydroxyl group of C7 of taxol.
Collapse
|
24
|
|
25
|
Hong Y, Ye SH, Pelinescu AL, Wagner WR. Synthesis, characterization, and paclitaxel release from a biodegradable, elastomeric, poly(ester urethane)urea bearing phosphorylcholine groups for reduced thrombogenicity. Biomacromolecules 2012; 13:3686-94. [PMID: 23035885 DOI: 10.1021/bm301158j] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Biodegradable polymers with high elasticity, low thrombogenicity, and drug loading capacity continue to be pursued for vascular engineering applications, including vascular grafts and stents. A biodegradable elastomeric polyurethane was designed as a candidate material for use as a drug-eluting stent coating, such that it was nonthrombogenic and could provide antiproliferative drug release to inhibit smooth muscle cell proliferation. A phosphorylcholine containing poly(ester urethane) urea (PEUU-PC) was synthesized by grafting aminated phosphorylcholine onto backbone carboxyl groups of a polyurethane (PEUU-COOH) synthesized from a soft segment blend of polycaprolactone and dimethylolpropionic acid, a hard segment of diisocyanatobutane and a putrescine chain extender. Poly(ester urethane) urea (PEUU) from a soft segment of polycaprolactone alone was employed as a control material. All of the synthesized polyurethanes showed high distensibility (>600%) and tensile strengths in the 20-35 MPa range. PEUU-PC experienced greater degradation than PEUU or PEUU-COOH in either a saline or lipase enzyme solution. PEUU-PC also exhibited markedly inhibited ovine blood platelet deposition compared with PEUU-COOH and PEUU. Paclitaxel loaded in all of the polymers during solvent casting continued to release for 5 d after a burst release in a 10% ethanol/PBS solution, which was utilized to increase the solubility of the releasate. Rat smooth muscle cell proliferation was significantly inhibited in 1 wk cell culture when releasate from the paclitaxel-loaded films was present. Based on these results, the synthesized PEUU-PC has promising functionality for use as a nonthrombogenic, drug eluting coating on metallic vascular stents and grafts.
Collapse
Affiliation(s)
- Yi Hong
- McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA 15219, USA
| | | | | | | |
Collapse
|
26
|
Cornacchione LA, Qi B, Bianco J, Zhou Z, Amsden BG. Photo-Cross-Linked Poly(ethylene carbonate) Elastomers: Synthesis, in Vivo Degradation, and Determination of in Vivo Degradation Mechanism. Biomacromolecules 2012; 13:3099-107. [DOI: 10.1021/bm300913q] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- L. A. Cornacchione
- Department of Chemical Engineering, Queen’s University, Kingston, ON, Canada
| | - B. Qi
- Department of Chemical Engineering, Queen’s University, Kingston, ON, Canada
| | - J. Bianco
- Department of Chemical Engineering, Queen’s University, Kingston, ON, Canada
| | - Z. Zhou
- Department of Chemical Engineering, Queen’s University, Kingston, ON, Canada
| | - B. G. Amsden
- Department of Chemical Engineering, Queen’s University, Kingston, ON, Canada
| |
Collapse
|