1
|
Lang T, Bramböck A, Thommes M, Bartsch J. Material Transport Characteristics in Planetary Roller Melt Granulation. Pharmaceutics 2023; 15:2039. [PMID: 37631253 PMCID: PMC10458212 DOI: 10.3390/pharmaceutics15082039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Revised: 07/20/2023] [Accepted: 07/27/2023] [Indexed: 08/27/2023] Open
Abstract
Melt granulation for improving material handling by modifying particle size distribution offers significant advantages compared to the standard methods of dry and wet granulation in dust reduction, obviating a subsequent drying step. Furthermore, current research in pharmaceutical technology aims for continuous methods, as these have an enhanced potential to reduce product quality fluctuations. Concerning both aspects, the use of a planetary roller granulator is consequential. The process control with these machines benefits from the enhanced ratio of heated surface to processed volume, compared to the usually-applied twin-screw systems. This is related to the unique concept of planetary spindles flowing around a central spindle in a roller cylinder. Herein, the movement pattern defines the transport characteristics, which determine the energy input and overall processing conditions. The aim of this study is to investigate the residence time distribution in planetary roller melt granulation (PRMG) as an indicator for the material transport. By altering feed rate and rotation speed, the fill level in the granulator is adjusted, which directly affects the average transport velocity and mixing volume. The two-compartment model was utilized to reflect these coherences, as the model parameters symbolize the sub-processes of axial material transport and mixing.
Collapse
Affiliation(s)
- Tom Lang
- Laboratory of Solids Process Engineering, Department of Biochemical and Chemical Engineering, TU Dortmund University, 44227 Dortmund, Germany (M.T.)
| | | | - Markus Thommes
- Laboratory of Solids Process Engineering, Department of Biochemical and Chemical Engineering, TU Dortmund University, 44227 Dortmund, Germany (M.T.)
| | - Jens Bartsch
- Laboratory of Solids Process Engineering, Department of Biochemical and Chemical Engineering, TU Dortmund University, 44227 Dortmund, Germany (M.T.)
| |
Collapse
|
2
|
Abdulhussain HA, Thompson MR. Considering Inelasticity in the Real-Time Monitoring of Particle Size for Twin-Screw Granulation via Acoustic Emissions. Int J Pharm 2023; 639:122949. [PMID: 37054925 DOI: 10.1016/j.ijpharm.2023.122949] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2023] [Revised: 03/29/2023] [Accepted: 04/08/2023] [Indexed: 04/15/2023]
Abstract
A recently developed process analytical technology (PAT) using artificial intelligence to form the framework of its model, combining frequency-domain acoustic emissions (AE) and elastic impact mechanics to accurately predict complex particle size distributions (PSD) in real-time. This model was modified in this study to give more accurate predictions for the more highly cohesive granules typical of pharmaceutical solid oral dosage formulations. AE spectra were collected from the granulated impacts of various formulations with ranging characteristics from largely elastic to highly inelastic collision responses. A viscoelastic (Hertzian spring-dashpot) and elastoplastic (Walton-Braun) contact force model were compared to understand how these different micro-mechanical approaches would affect the prediction accuracy of particle sizes relevant to granulation. Retraining the artificial intelligence model with the Walton-Braun transformation and a more comprehensive dataset of AE spectra spanning a broad range of granulated formulations showed the prediction error drop to as low as 2% compared to the original elastic version showing errors as large as 18.6% with representative formulations of the industry. The improved PAT shows good applicability to monitoring bimodal PSD that are typical of continuous twin-screw granulation.
Collapse
Affiliation(s)
- H A Abdulhussain
- CAPPA-D/MMRI, Department of Chemical Engineering, McMaster University, Hamilton, Ontario, Canada
| | - M R Thompson
- CAPPA-D/MMRI, Department of Chemical Engineering, McMaster University, Hamilton, Ontario, Canada.
| |
Collapse
|
3
|
Toson P, Khinast JG. A DEM Model to Evaluate Refill Strategies of a Twin-Screw Feeder. Int J Pharm 2023; 641:122915. [PMID: 37015295 DOI: 10.1016/j.ijpharm.2023.122915] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 03/28/2023] [Accepted: 03/29/2023] [Indexed: 04/04/2023]
Abstract
Residence time distribution (RTD) modeling has proven to be a valuable tool for material tracking in continuous pharmaceutical processes. Refilling is thoroughly studied in the literature, but the main focus lies on the feed rate disturbances. The impact of the feeders themselves on intermixing of different material batches is often overlooked. Since the experimental methods to measure the RTD feeder discharging processes feeder are complex and material intensive, there is only limited experimental RTD data available in the literature. A DEM (discrete element method) simulation of a discharge of a twin-screw feeder shows that a large fraction of material that is moved and intermixed by the agitator. In addition to the intermixing, there is a tendency to discharge material located above the agitator early. In order to predict the behavior during multiple refill events, three models in order of increasing complexity are presented: (1) A simple exponential RTD assuming perfect intermixing of material batches; (2) a RTD model based on DEM results; (3) particle-level material tracking by extrapolation of the DEM results. All three of these models are able to predict the survival function of old material for late refills at low fill levels, however, earlier refills at high fill levels require more complex models to accurately represent the dynamics inside the hopper of the feeder.
Collapse
|
4
|
Elucidation of the powder flow pattern in a twin-screw LIW-feeder for various refill regimes. Int J Pharm 2023; 631:122534. [PMID: 36563797 DOI: 10.1016/j.ijpharm.2022.122534] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Revised: 12/16/2022] [Accepted: 12/19/2022] [Indexed: 12/24/2022]
Abstract
The importance of residence time distribution modeling is acknowledged as a tool for enabling material tracking and control within a continuous manufacturing line in order to safeguard both product quality and production efficiency. One of the first unit-operations into a continuous direct compression line (i.e. CDC-line) worthwhile doing extensive RTD-analysis upon are the LIW-feeders since they dose the ingredients in a controlled way following the label claim and hence can directly influence critical quality attributes like content uniformity. An NIR measurement method was developed determining the RTD of selected powders at specific feeder settings. Step-change experiments using sodium saccharin as a tracer were conducted. In order to gain and in depth understanding of the material flow, spatial samples throughout the hopper were taken at predefined timepoints during the step change experiments. This revealed the presence of a bypass trajectory along the edges of the agitator, while in the center of the agitator an inner mixing volume in which the tracer concentration lags behind seemed to be present. Finally, a model based on a plug flow and continuous stirred tank reactor was evaluated. The fitted model was not able to capture this complex flow behavior and shows the need for an extended compartmental model distinguishing between a bypass trajectory formed by the agitator and an inner mixing volume.
Collapse
|
5
|
Klinken S, Quodbach J. Sums of amplitudes analysis – A new non-parametric classification method for time series deviation evaluation in pharmaceutical processes. POWDER TECHNOL 2022. [DOI: 10.1016/j.powtec.2022.118003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
|
6
|
Predicting powder feedability: A workflow for assessing the risk of flow stagnation and defining the operating space for different powder-feeder combinations. Int J Pharm 2022; 629:122364. [DOI: 10.1016/j.ijpharm.2022.122364] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Revised: 10/28/2022] [Accepted: 10/30/2022] [Indexed: 11/06/2022]
|
7
|
Madarász L, Köte Á, Hambalkó B, Csorba K, Kovács V, Lengyel L, Marosi G, Farkas A, Nagy ZK, Domokos A. In-line particle size measurement based on image analysis in a fully continuous granule manufacturing line for rapid process understanding and development. Int J Pharm 2022; 612:121280. [PMID: 34774695 DOI: 10.1016/j.ijpharm.2021.121280] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Revised: 10/27/2021] [Accepted: 11/06/2021] [Indexed: 12/01/2022]
Abstract
The present paper serves as a demonstration how an in-line PAT tool can be used for rapid and efficient process development in a fully continuous powder to granule line consisting of an interconnected twin-screw wet granulator, vibrational fluid bed dryer, and a regranulating mill. A new method was investigated for the periodic in-line particle size measurement of high mass flow materials to obtain real-time particle size data of the regranulated product. The system utilises a vibratory feeder with periodically altered feeding intensity in order to temporarily reduce the mass flow of the material passing in front of the camera. This results in the drastic reduction of particle overlapping in the images, making image analysis a viable tool for the in-line particle size measurement of high mass-flow materials. To evaluate the performance of the imaging system, the effect of several milling settings and the liquid-to-solid ratio was investigated on the product's particle size in the span of a few hours. The particle sizes measured with the in-line system were in accordance with the expected trends as well as with the results of the off-line reference particle size measurements. Based on the results, the in-line imaging system can serve as a PAT tool to obtain valuable real-time information for rapid process development or quality assurance.
Collapse
Affiliation(s)
- Lajos Madarász
- Department of Organic Chemistry and Technology, Budapest University of Technology and Economics, H-1111 Budapest, Műegyetem rakpart 3, Hungary
| | - Ákos Köte
- Department of Automation and Applied Informatics, Budapest University of Technology and Economics, H-1117, Budapest Magyar Tudósok körútja 2 QB-207, Hungary
| | - Bence Hambalkó
- Department of Automation and Applied Informatics, Budapest University of Technology and Economics, H-1117, Budapest Magyar Tudósok körútja 2 QB-207, Hungary
| | - Kristóf Csorba
- Department of Automation and Applied Informatics, Budapest University of Technology and Economics, H-1117, Budapest Magyar Tudósok körútja 2 QB-207, Hungary
| | - Viktor Kovács
- Department of Automation and Applied Informatics, Budapest University of Technology and Economics, H-1117, Budapest Magyar Tudósok körútja 2 QB-207, Hungary
| | - László Lengyel
- Department of Automation and Applied Informatics, Budapest University of Technology and Economics, H-1117, Budapest Magyar Tudósok körútja 2 QB-207, Hungary
| | - György Marosi
- Department of Organic Chemistry and Technology, Budapest University of Technology and Economics, H-1111 Budapest, Műegyetem rakpart 3, Hungary
| | - Attila Farkas
- Department of Organic Chemistry and Technology, Budapest University of Technology and Economics, H-1111 Budapest, Műegyetem rakpart 3, Hungary
| | - Zsombor Kristóf Nagy
- Department of Organic Chemistry and Technology, Budapest University of Technology and Economics, H-1111 Budapest, Műegyetem rakpart 3, Hungary.
| | - András Domokos
- Department of Organic Chemistry and Technology, Budapest University of Technology and Economics, H-1111 Budapest, Műegyetem rakpart 3, Hungary
| |
Collapse
|
8
|
Peterwitz M, Gerling S, Schembecker G. Challenges in tracing material flow passing a loss-in-weight feeder in continuous manufacturing processes. Int J Pharm 2022; 612:121304. [PMID: 34800615 DOI: 10.1016/j.ijpharm.2021.121304] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2021] [Revised: 11/11/2021] [Accepted: 11/13/2021] [Indexed: 12/31/2022]
Abstract
Loss-in-weight feeders are an integral part of most continuous manufacturing processes, ensuring a constant mass flow. The feeders cause a significant degree of back-mixing in such lines. Understanding back-mixing is essential for the treatment of disturbances. However, feeders refilled semi-continuously contradict the common theory assuming steady-state. This study aims at understanding dynamic back-mixing and related phenomena. Low filling levels of a feeder are investigated using a fluorescent tracer. These investigations prove an impact of the addition of material probably caused by a non-uniform draw-in of the screws and dead material in the hopper. In turn, the dead material accounts for up to 50 % of the material in the hopper. Possible evidence of dead zones at higher filling levels and in feeders from literature are discussed additionally. Steady-state models from literature are extended to represent the observations and back-mixing at all filling levels. This extension reduces the root-mean-squared deviation of the model from the experimental data by 41%. The model predicts different responses to similar disturbances depending on the filling. This state-dependent back-mixing and the observed dead zones are challenging for diverting non-conforming material and material traceability. Therefore, these phenomena should be considered in selecting and operating feeders.
Collapse
Affiliation(s)
- Moritz Peterwitz
- Laboratory of Plant and Process Design, Faculty of Biochemical and Chemical Engineering, TU Dortmund University, Emil-Figge-Straße 70, D-44227 Dortmund, Germany; Invite GmbH, Otto-Bayer-Straße 32, D-51061 Cologne, Germany
| | - Sina Gerling
- Laboratory of Plant and Process Design, Faculty of Biochemical and Chemical Engineering, TU Dortmund University, Emil-Figge-Straße 70, D-44227 Dortmund, Germany
| | - Gerhard Schembecker
- Laboratory of Plant and Process Design, Faculty of Biochemical and Chemical Engineering, TU Dortmund University, Emil-Figge-Straße 70, D-44227 Dortmund, Germany.
| |
Collapse
|
9
|
Quodbach J, Bogdahn M, Breitkreutz J, Chamberlain R, Eggenreich K, Elia AG, Gottschalk N, Gunkel-Grabole G, Hoffmann L, Kapote D, Kipping T, Klinken S, Loose F, Marquetant T, Windolf H, Geißler S, Spitz T. Quality of FDM 3D Printed Medicines for Pediatrics: Considerations for Formulation Development, Filament Extrusion, Printing Process and Printer Design. Ther Innov Regul Sci 2021; 56:910-928. [PMID: 34826120 PMCID: PMC9492703 DOI: 10.1007/s43441-021-00354-0] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Accepted: 11/04/2021] [Indexed: 02/08/2023]
Abstract
3d printing is capable of providing dose individualization for pediatric medicines and translating the precision medicine approach into practical application. In pediatrics, dose individualization and preparation of small dosage forms is a requirement for successful therapy, which is frequently not possible due to the lack of suitable dosage forms. For precision medicine, individual characteristics of patients are considered for the selection of the best possible API in the most suitable dose with the most effective release profile to improve therapeutic outcome. 3d printing is inherently suitable for manufacturing of individualized medicines with varying dosages, sizes, release profiles and drug combinations in small batch sizes, which cannot be manufactured with traditional technologies. However, understanding of critical quality attributes and process parameters still needs to be significantly improved for this new technology. To ensure health and safety of patients, cleaning and process validation needs to be established. Additionally, adequate analytical methods for the in-process control of intermediates, regarding their printability as well as control of the final 3d printed tablets considering any risk of this new technology will be required. The PolyPrint consortium is actively working on developing novel polymers for fused deposition modeling (FDM) 3d printing, filament formulation and manufacturing development as well as optimization of the printing process, and the design of a GMP-capable FDM 3d printer. In this manuscript, the consortium shares its views on quality aspects and measures for 3d printing from drug-loaded filaments, including formulation development, the printing process, and the printed dosage forms. Additionally, engineering approaches for quality assurance during the printing process and for the final dosage form will be presented together with considerations for a GMP-capable printer design.
Collapse
Affiliation(s)
- Julian Quodbach
- Institute of Pharmaceutics and Biopharmaceutics, Heinrich Heine University Düsseldorf, Universitätsstr. 1, 40225, Düsseldorf, Germany.
| | - Malte Bogdahn
- Merck Healthcare KGaA, Frankfurter Str. 250, Darmstadt, Germany
| | - Jörg Breitkreutz
- Institute of Pharmaceutics and Biopharmaceutics, Heinrich Heine University Düsseldorf, Universitätsstr. 1, 40225, Düsseldorf, Germany
| | - Rebecca Chamberlain
- Institute of Pharmaceutics and Biopharmaceutics, Heinrich Heine University Düsseldorf, Universitätsstr. 1, 40225, Düsseldorf, Germany
| | | | | | | | | | - Lena Hoffmann
- Institute of Pharmaceutics and Biopharmaceutics, Heinrich Heine University Düsseldorf, Universitätsstr. 1, 40225, Düsseldorf, Germany
| | | | - Thomas Kipping
- Merck Life Science KGaA, Frankfurter Str. 250, Darmstadt, Germany
| | - Stefan Klinken
- Institute of Pharmaceutics and Biopharmaceutics, Heinrich Heine University Düsseldorf, Universitätsstr. 1, 40225, Düsseldorf, Germany
| | - Fabian Loose
- Laboratory for Manufacturing Systems, University of Applied Sciences Cologne, Betzdorfer Str. 2, 50679, Cologne, Germany
| | | | - Hellen Windolf
- Institute of Pharmaceutics and Biopharmaceutics, Heinrich Heine University Düsseldorf, Universitätsstr. 1, 40225, Düsseldorf, Germany
| | - Simon Geißler
- Merck Healthcare KGaA, Frankfurter Str. 250, Darmstadt, Germany
| | - Tilmann Spitz
- Laboratory for Manufacturing Systems, University of Applied Sciences Cologne, Betzdorfer Str. 2, 50679, Cologne, Germany
| |
Collapse
|
10
|
Beke ÁK, Gyürkés M, Nagy ZK, Marosi G, Farkas A. Digital twin of low dosage continuous powder blending - Artificial neural networks and residence time distribution models. Eur J Pharm Biopharm 2021; 169:64-77. [PMID: 34562574 DOI: 10.1016/j.ejpb.2021.09.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Revised: 08/24/2021] [Accepted: 09/17/2021] [Indexed: 10/20/2022]
Abstract
In this paper we present a thorough description of the digital twin development for a continuous pharmaceutical powder blending process in accordance with the Process Analytical Technologies (PAT) and Quality by Design (QbD) guidelines. A low-dosage system of caffeine active pharmaceutical ingredient (API) and dextrose excipient was examined via continuous blending experiments. Near infrared (NIR) spectroscopy-based process analytics were applied; quantitative evaluation of spectra was achieved using multivariate data analysis. The blending system was represented with mechanistic residence time distribution (RTD) models and two types of recurrent artificial neural networks (ANN), experimental datasets were used for model training or fitting and validation. Detailed comparison of the two modelling approaches, the optimization of the model-based digital twin, and efficiency of the soft sensor-based process monitoring is presented through several validating simulations. Both RTD models and nonlinear autoregressive neural networks demonstrated excellent predictive power for the low dosage blending process. RTD models can prove to be more advantageous in industrial development as they are less resource-intensive to develop and prediction accuracy on low concentration levels lacks dependency from the precision of chemometric calibration. Reduced material costs and limited development timeframe render the digital twin an efficient tool in technological development.
Collapse
Affiliation(s)
- Áron Kristóf Beke
- Department of Organic Chemistry and Technology, Budapest University of Technology and Economics (BME), Műegyetem rakpart 3, Budapest H-1111, Hungary
| | - Martin Gyürkés
- Department of Organic Chemistry and Technology, Budapest University of Technology and Economics (BME), Műegyetem rakpart 3, Budapest H-1111, Hungary
| | - Zsombor Kristóf Nagy
- Department of Organic Chemistry and Technology, Budapest University of Technology and Economics (BME), Műegyetem rakpart 3, Budapest H-1111, Hungary
| | - György Marosi
- Department of Organic Chemistry and Technology, Budapest University of Technology and Economics (BME), Műegyetem rakpart 3, Budapest H-1111, Hungary
| | - Attila Farkas
- Department of Organic Chemistry and Technology, Budapest University of Technology and Economics (BME), Műegyetem rakpart 3, Budapest H-1111, Hungary.
| |
Collapse
|
11
|
Effects of signal processing on the relative standard deviation in powder feeding characterization for continuous manufacturing. POWDER TECHNOL 2021. [DOI: 10.1016/j.powtec.2021.05.068] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
12
|
Ryckaert A, Stauffer F, Funke A, Djuric D, Vanhoorne V, Vervaet C, De Beer T. Evaluation of torque as an in-process control for granule size during twin-screw wet granulation. Int J Pharm 2021; 602:120642. [PMID: 33933640 DOI: 10.1016/j.ijpharm.2021.120642] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Revised: 04/20/2021] [Accepted: 04/21/2021] [Indexed: 10/21/2022]
Abstract
The potential of torque as in-process control (IPC) to monitor granule size in twin-screw wet granulation (TSG) was investigated. An experimental set-up allowing the collection of granules at four different locations (i.e., in the wetting zone, after the first and second kneading zone and at the end of the granulator) of the granulator screws was used to determine the change in granule size, granule temperature and the contribution of each compartment to the overall torque for varying screw speed, mass feed rate and liquid-to-solid ratio. The only observed correlation was between the granule size and torque increase after the first kneading zone because the torque increase was an indication of the degree in granule growth which was consistently observed with all applied granulation process parameters. No correlation was observed in the other locations as changes of torque were accompanied to either granule breakage and/or growth. Moreover, torque increase was correlated to higher granule temperature, suggesting that energy put into the granulator was partly used to heat up the material being processed and explains additionally the lack of correlation between granule size and torque. Therefore, this study showed that torque could not be used as IPC to monitor granule size during TSG.
Collapse
Affiliation(s)
- A Ryckaert
- Laboratory of Pharmaceutical Process Analytical Technology, Department of Pharmaceutical analysis, Ghent University, Ottergemsesteenweg 460, 9000, Ghent, Belgium.
| | - F Stauffer
- Laboratory of Pharmaceutical Process Analytical Technology, Department of Pharmaceutical analysis, Ghent University, Ottergemsesteenweg 460, 9000, Ghent, Belgium.
| | - A Funke
- Chemical & Pharmaceutical Development, Pharma R&D, Bayer AG, Friedrich-Ebert-Straße 475, 42369, Wuppertal, Germany.
| | - D Djuric
- Chemical & Pharmaceutical Development, Pharma R&D, Bayer AG, Friedrich-Ebert-Straße 475, 42369, Wuppertal, Germany.
| | - V Vanhoorne
- Laboratory of Pharmaceutical Technology, Department of Pharmaceutics Ghent University, Ottergemsesteenweg 460, Ghent, Belgium.
| | - C Vervaet
- Laboratory of Pharmaceutical Technology, Department of Pharmaceutics Ghent University, Ottergemsesteenweg 460, Ghent, Belgium.
| | - T De Beer
- Laboratory of Pharmaceutical Process Analytical Technology, Department of Pharmaceutical analysis, Ghent University, Ottergemsesteenweg 460, 9000, Ghent, Belgium.
| |
Collapse
|
13
|
Application of PAT-Based Feedback Control Approaches in Pharmaceutical Crystallization. CRYSTALS 2021. [DOI: 10.3390/cryst11030221] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Crystallization is one of the important unit operations for the separation and purification of solid products in the chemical, pharmaceutical, and pesticide industries, especially for realizing high-end, high-value solid products. The precise control of the solution crystallization process determines the polymorph, crystal shape, size, and size distribution of the crystal product, which is of great significance to improve product quality and production efficiency. In order to develop the crystallization process in a scientific method that is based on process parameters and data, process analysis technology (PAT) has become an important enabling platform. In this paper, we review the development of PAT in the field of crystallization in recent years. Based on the current research status of drug crystallization process control, the monitoring methods and control strategies of feedback control in the crystallization process were systematically summarized. The focus is on the application of model-free feedback control strategies based on the solution and solid information collected by various online monitoring equipment in product engineering, including improving particle size distribution, achieving polymorphic control, and improving purity. In this paper, the challenges of feedback control strategy in the crystallization process are also discussed, and the development trend of the feedback control strategy has been prospected.
Collapse
|
14
|
Sacher S, Heindl N, Afonso Urich JA, Kruisz J, Khinast JG. A solution for low-dose feeding in continuous pharmaceutical processes. Int J Pharm 2020; 591:119969. [PMID: 33068692 DOI: 10.1016/j.ijpharm.2020.119969] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Revised: 10/07/2020] [Accepted: 10/08/2020] [Indexed: 11/18/2022]
Abstract
Continuous feeding of small quantities of powder is increasingly applied in pharmaceutical manufacturing. With that regard, what is crucial is not only the feasibility, but also the accuracy and stability. To enable stable processing, low amounts of various agents, e.g., lubricants, can be used. Even more important is the exact dosage of highly potent active pharmaceutical ingredients (APIs), which require feed rates within the range of grams per hour. Conventional feeders cannot supply powder at such rates, especially when the material properties are challenging. In this work, a novel micro-feeder was integrated into a continuous manufacturing line and its capability to supply API at feed rates down to one gram per hour was tested. The micro-feeder system is based on the principle of active volumetric displacement: a piston pushes the powder out of the cartridge upwards to the end of a plate, where a scraper places it into the process inlet. In this study, a hot melt extrusion process was used, during which the API was dissolved in a polymer matrix. Samples of the strand were analysed with regard to their content by means of HPLC. The results showed that the novel micro-feeder system can feed powder with good accuracy and reproducibility, indicating its high potential for continuous process implementation.
Collapse
Affiliation(s)
- Stephan Sacher
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13/2, 8010 Graz, Austria.
| | - Nikolaus Heindl
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13/2, 8010 Graz, Austria
| | | | - Julia Kruisz
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13/2, 8010 Graz, Austria
| | - Johannes G Khinast
- Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13/2, 8010 Graz, Austria; Institute for Process and Particle Engineering, Graz University of Technology, Inffeldgasse 13/3, 8010 Graz, Austria
| |
Collapse
|
15
|
Comparison between twin-screw and high-shear granulation - The effect of filler and active pharmaceutical ingredient on the granule and tablet properties. POWDER TECHNOL 2020. [DOI: 10.1016/j.powtec.2020.08.030] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
16
|
Madarász L, Köte Á, Gyürkés M, Farkas A, Hambalkó B, Pataki H, Fülöp G, Marosi G, Lengyel L, Casian T, Csorba K, Nagy ZK. Videometric mass flow control: A new method for real-time measurement and feedback control of powder micro-feeding based on image analysis. Int J Pharm 2020; 580:119223. [DOI: 10.1016/j.ijpharm.2020.119223] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2020] [Revised: 03/07/2020] [Accepted: 03/09/2020] [Indexed: 12/21/2022]
|
17
|
Vanhoorne V, Vervaet C. Recent progress in continuous manufacturing of oral solid dosage forms. Int J Pharm 2020; 579:119194. [PMID: 32135231 DOI: 10.1016/j.ijpharm.2020.119194] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Revised: 02/28/2020] [Accepted: 02/29/2020] [Indexed: 12/28/2022]
Abstract
Continuous drug product manufacturing is slowly being implemented in the pharmaceutical industry. Although the benefits related to the quality and cost of continuous manufacturing are widely recognized, several challenges hampered the widespread introduction of continuous manufacturing of drug products. Current review presents an overview of state-of-the art research, equipment, process analytical technology implementations and advanced control strategies. Additionally, guidelines and regulatory viewpoints on implementation of continuous manufacturing in the pharmaceutical industry are discussed.
Collapse
Affiliation(s)
- V Vanhoorne
- Laboratory of Pharmaceutical Technology, Ghent University
| | - C Vervaet
- Laboratory of Pharmaceutical Technology, Ghent University.
| |
Collapse
|
18
|
Hsiao WK, Hörmann TR, Toson P, Paudel A, Ghiotti P, Stauffer F, Bauer F, Lakio S, Behrend O, Maurer R, Holman J, Khinast J. Feeding of particle-based materials in continuous solid dosage manufacturing: a material science perspective. Drug Discov Today 2020; 25:800-806. [PMID: 31982395 DOI: 10.1016/j.drudis.2020.01.013] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2019] [Revised: 12/17/2019] [Accepted: 01/16/2020] [Indexed: 11/16/2022]
Abstract
The pharmaceutical industry today is experiencing a paradigm shift from batch to continuous manufacturing, which promises greater flexibility to target diverse populations, as well as more-consistent product quality to ensure best efficacy. However, shifting to continuous processing means that even basic process steps, such as feeding, can become unexpected but are crucially important. In this review, we will present the fundamental differences between dispensing (batch) and feeding (continuous) and how they impact the formulation design space. We will further outline our rational development approach, applicable to continuous unit operations in general, which includes standardized material and process characterization, as well as predictive modeling based on advanced, multidomain simulation tools.
Collapse
Affiliation(s)
- Wen-Kai Hsiao
- Research Center Pharmaceutical Engineering GmbH, Graz, Austria; European Consortium of Continuous Pharmaceutical Manufacturing (eccpm.com)
| | - Theresa R Hörmann
- Research Center Pharmaceutical Engineering GmbH, Graz, Austria; European Consortium of Continuous Pharmaceutical Manufacturing (eccpm.com); Graz University of Technology, Graz, Austria
| | - Peter Toson
- Research Center Pharmaceutical Engineering GmbH, Graz, Austria
| | - Amrit Paudel
- Research Center Pharmaceutical Engineering GmbH, Graz, Austria; European Consortium of Continuous Pharmaceutical Manufacturing (eccpm.com); Graz University of Technology, Graz, Austria
| | - Patrizia Ghiotti
- European Consortium of Continuous Pharmaceutical Manufacturing (eccpm.com); UCB Pharma S.A., Brussels, Belgium
| | - Fanny Stauffer
- European Consortium of Continuous Pharmaceutical Manufacturing (eccpm.com); UCB Pharma S.A., Brussels, Belgium
| | - Finn Bauer
- European Consortium of Continuous Pharmaceutical Manufacturing (eccpm.com); Merck KGaA, Darmstadt, Germany
| | - Satu Lakio
- European Consortium of Continuous Pharmaceutical Manufacturing (eccpm.com); Orion Pharma, Espoo, Finland
| | - Olaf Behrend
- European Consortium of Continuous Pharmaceutical Manufacturing (eccpm.com); Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - Reto Maurer
- European Consortium of Continuous Pharmaceutical Manufacturing (eccpm.com); F. Hoffmann-La Roche Ltd, Basel, Switzerland
| | - James Holman
- European Consortium of Continuous Pharmaceutical Manufacturing (eccpm.com); GEA Group, Wommelgem, Belgium
| | - Johannes Khinast
- Research Center Pharmaceutical Engineering GmbH, Graz, Austria; European Consortium of Continuous Pharmaceutical Manufacturing (eccpm.com); Graz University of Technology, Graz, Austria.
| |
Collapse
|
19
|
Zhang Y, Cheng BCY, Zhou W, Xu B, Gao X, Qiao Y, Luo G. Improved Understanding of the High Shear Wet Granulation Process under the Paradigm of Quality by Design Using Salvia miltiorrhiza Granules. Pharmaceutics 2019; 11:E519. [PMID: 31600941 PMCID: PMC6835650 DOI: 10.3390/pharmaceutics11100519] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2019] [Revised: 09/27/2019] [Accepted: 10/06/2019] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND High shear wet granulation (HSWG) is a shaping process for granulation that has been enhanced for application in the pharmaceutical industry. However, study of HSWG is complex and challenging due to the relatively poor understanding of HSWG, especially for sticky powder-like herbal extracts. AIM In this study, we used Salvia miltiorrhiza granules to investigate the HSWG process across different scales using quality by design (QbD) approaches. METHODS A Plackett-Burman experimental design was used to screen nine granulation factors in the HSWG process. Moreover, a quadratic polynomial regression model was established based on a Box-Behnken experimental design to optimize the granulation factors. In addition, the scale-up of HSWG was implemented based on a nucleation regime map approach. RESULTS According to the Plackett-Burman experimental design, it was found that three granulation factors, including salvia ratio, binder amount, and chopper speed, significantly affected the granule size (D50) of S. miltiorrhiza in HSWG. Furthermore, the results of the Box-Behnken experimental design and validation experiment showed that the model successfully captured the quadratic polynomial relationship between granule size and the two granulation factors of salvia ratio and binder amount. At the same experiment points, granules at all scales had similar size distribution, surface morphology, and flow properties. CONCLUSIONS These results demonstrated that rational design, screening, optimization, and scale-up of HSWG are feasible using QbD approaches. This study provides a better understanding of HSWG process under the paradigm of QbD using S. miltiorrhiza granules.
Collapse
Affiliation(s)
- Yi Zhang
- School of Chinese Material Medica, Beijing University of Chinese Medicine, Beijing 100029, China.
| | - Brian Chi-Yan Cheng
- College of Professional and Continuing Education, Hong Kong Polytechnic University, Hong Kong 999077, China.
| | - Wenjuan Zhou
- School of Chinese Material Medica, Beijing University of Chinese Medicine, Beijing 100029, China.
- Interdisciplinary Research Center on Multi-Omics of Traditional Chinese Medicine, Beijing University of Chinese Medicine, Beijing 102400, China.
| | - Bing Xu
- School of Chinese Material Medica, Beijing University of Chinese Medicine, Beijing 100029, China.
- Beijing Key Laboratory for Production Process Control and Quality Evaluation of Traditional Chinese Medicine, Beijing Municipal Science & Technology Commission, Beijing 102400, China.
| | - Xiaoyan Gao
- School of Chinese Material Medica, Beijing University of Chinese Medicine, Beijing 100029, China.
- Interdisciplinary Research Center on Multi-Omics of Traditional Chinese Medicine, Beijing University of Chinese Medicine, Beijing 102400, China.
- Beijing Key Laboratory for Production Process Control and Quality Evaluation of Traditional Chinese Medicine, Beijing Municipal Science & Technology Commission, Beijing 102400, China.
| | - Yanjiang Qiao
- School of Chinese Material Medica, Beijing University of Chinese Medicine, Beijing 100029, China.
- Beijing Key Laboratory for Production Process Control and Quality Evaluation of Traditional Chinese Medicine, Beijing Municipal Science & Technology Commission, Beijing 102400, China.
| | - Gan Luo
- School of Chinese Material Medica, Beijing University of Chinese Medicine, Beijing 100029, China.
- Interdisciplinary Research Center on Multi-Omics of Traditional Chinese Medicine, Beijing University of Chinese Medicine, Beijing 102400, China.
- Beijing Key Laboratory for Production Process Control and Quality Evaluation of Traditional Chinese Medicine, Beijing Municipal Science & Technology Commission, Beijing 102400, China.
| |
Collapse
|
20
|
Sensitivity of a continuous hot-melt extrusion and strand pelletization line to control actions and composition variation. Int J Pharm 2019; 566:239-253. [DOI: 10.1016/j.ijpharm.2019.05.046] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2019] [Revised: 05/14/2019] [Accepted: 05/15/2019] [Indexed: 11/20/2022]
|
21
|
Pauli V, Roggo Y, Kleinebudde P, Krumme M. Real-time monitoring of particle size distribution in a continuous granulation and drying process by near infrared spectroscopy. Eur J Pharm Biopharm 2019; 141:90-99. [PMID: 31082510 DOI: 10.1016/j.ejpb.2019.05.007] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2018] [Revised: 04/26/2019] [Accepted: 05/09/2019] [Indexed: 11/28/2022]
Abstract
In continuous granulation, it can be important to control granules particle size distribution (PSD), as it may affect final product quality. Near infrared spectroscopy (NIRS) is already a routine analytical procedure within pharmaceutical continuous manufacturing for the in-line analysis of chemical material-characteristics. Consequently, the extraction of additional information related to granules' physical properties like particle size distribution is tempting, as it would enhance process knowledge without the need for new capital investments. Three in-line NIRS methods were developed via partial least squares regression, to predict dried granules PSD-fractions X10, X50, and X90 within a GMP-qualified continuous twin-screw wet granulation and fluid-bed drying process. Methods were developed for the size range of 20-234 µm (X10), 98-1017 µm (X50), and 748-2297 µm (X90) and assessed with one internal and three external validation datasets in agreement with current guidelines on NIRS. Internal validation indicated root mean square error of predictions (RMSEPs) of 17 µm, 97 µm, and 174 µm, for PSD X10, X50, and X90 respectively, with acceptable linearity, slope, and bias. Furthermore, the ratio of prediction to deviation (RPD), the ratio of prediction error to laboratory error (PRL), and the range error ratio (RER) were evaluated, with all values within the acceptance range for adequate to good NIR methods (1.75 > RPD < 3, PRL ≤ 2, RER ≥ 10). Methods applicability to in-line processes and their robustness towards water content and active pharmaceutical ingredient content was further demonstrated with three independent in-line datasets in real-time, showing good agreement between predicted and reference values. In summary, methods demonstrated to be sufficient for their intended purpose to monitor trends and sudden changes in dried granules PSD during continuous granulation and drying. Because of their fast response time, they are unique tools to characterize the dynamic behavior and navigate the agglomeration state of the material in static and transient process conditions during continuous granulation and drying.
Collapse
Affiliation(s)
- Victoria Pauli
- Institute of Pharmaceutics and Biopharmaceutics, Heinrich Heine University, Universitaetsstr. 1, 40225 Dusseldorf, Germany; Novartis AG, 4002 Basel, Switzerland
| | | | - Peter Kleinebudde
- Institute of Pharmaceutics and Biopharmaceutics, Heinrich Heine University, Universitaetsstr. 1, 40225 Dusseldorf, Germany
| | | |
Collapse
|
22
|
Bostijn N, Van Renterghem J, Vanbillemont B, Dhondt W, Vervaet C, De Beer T. Continuous manufacturing of a pharmaceutical cream: Investigating continuous powder dispersing and residence time distribution (RTD). Eur J Pharm Sci 2019; 132:106-117. [DOI: 10.1016/j.ejps.2019.02.036] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2019] [Revised: 02/28/2019] [Accepted: 02/28/2019] [Indexed: 01/09/2023]
|
23
|
Impact of material properties and process variables on the residence time distribution in twin screw feeding equipment. Int J Pharm 2019; 556:200-216. [DOI: 10.1016/j.ijpharm.2018.11.076] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2018] [Revised: 11/29/2018] [Accepted: 11/30/2018] [Indexed: 11/22/2022]
|
24
|
Hydrophobic/hydrophilic powders: Practical implications of screw element type on the reduction of fines in twin screw granulation. POWDER TECHNOL 2019. [DOI: 10.1016/j.powtec.2018.03.018] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
25
|
Stauffer F, Vanhoorne V, Pilcer G, Chavez PF, Schubert MA, Vervaet C, De Beer T. Managing active pharmaceutical ingredient raw material variability during twin-screw blend feeding. Eur J Pharm Biopharm 2018; 135:49-60. [PMID: 30582959 DOI: 10.1016/j.ejpb.2018.12.012] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2018] [Revised: 10/31/2018] [Accepted: 12/20/2018] [Indexed: 10/27/2022]
Abstract
Continuous powder feeding is a critical step in continuous manufacturing of solid dosage forms, as this unit operation should ensure the mass flow consistency at the desired powder feed rate to guarantee the process throughput and final product consistency. In this study, twin-screw feeding of a pharmaceutical formulation (i.e., blend) existing of a highly dosed very poorly flowing active pharmaceutical ingredient (API) leading to insufficient feeding capacity was investigated. Furthermore, the API showed very high batch-to-batch variability in raw material properties dominating the formulation blend properties. Formulation changes were evaluated to improve the flowability of the blends and to mitigate the impact of API batch-to-batch variability on the twin-screw feeding. Herewith, feeding evaluation tests and an extensive material characterization of the reformulated blends were performed to assess the impact of the formulation changes upon continuous twin-screw feeding. The transfer of the glidant from extra-granular to intra-granular phase allowed to improve the flowability of the blends. A sufficient feeding capacity for the downstream process and a mitigation of the impact of batch-to-batch variability of the API upon twin-screw feeding of the blends could be achieved. No effect of the formulation or of the API properties on the feeding stability was observed. The material characterization of the blends allowed identifying the material attributes which were critical for continuous twin-screw feeding (i.e., bulk density, mass charge and powder cohesiveness).
Collapse
Affiliation(s)
- F Stauffer
- Laboratory of Pharmaceutical Process Analytical Technology, Ghent University, Ghent, Belgium
| | - V Vanhoorne
- Laboratory of Pharmaceutical Technology, Ghent University, Ghent, Belgium
| | - G Pilcer
- Drug Delivery Design and Development, UCB, Braine l'Alleud, Belgium
| | | | - M A Schubert
- Drug Delivery Design and Development, UCB, Braine l'Alleud, Belgium
| | - C Vervaet
- Laboratory of Pharmaceutical Technology, Ghent University, Ghent, Belgium
| | - T De Beer
- Laboratory of Pharmaceutical Process Analytical Technology, Ghent University, Ghent, Belgium
| |
Collapse
|
26
|
Schmidt A, de Waard H, Moll KP, Kleinebudde P, Krumme M. Simplified end-to-end continuous manufacturing by feeding API suspensions in twin-screw wet granulation. Eur J Pharm Biopharm 2018; 133:224-231. [PMID: 30291963 DOI: 10.1016/j.ejpb.2018.09.026] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2018] [Revised: 09/25/2018] [Accepted: 09/25/2018] [Indexed: 11/26/2022]
Abstract
This study focussed on investigating the coupling of continuous manufacturing of drug substance and continuous manufacture of drug product. An important step in such an integrated end-to-end continuous manufacturing was envisioned by dosing the API as suspension into a twin-screw wet granulation process. To achieve this goal, a model drug substance (ibuprofen) was fed as a concentrated aqueous suspension (50% w/w) into a twin-screw granulator and compared against traditional solid feeding of the model drug substance to meet a target ibuprofen load of 60% w/w in the formulation. Granulation and compaction behaviour were evaluated to determine the impact of feeding API as suspension in twin-screw wet granulation on the critical quality attributes of the drug product. It was demonstrated that the ibuprofen suspension feed is comparable with the ibuprofen dry blend feed in twin-screw wet granulation. Next to enabling end-to-end continuous manufacturing, API suspension feed in twin-screw wet granulation could afford a number of additional advantages including manufacturing efficiency by removing the drying step for API, or overcoming processing issues linked to the bulk properties of the API powder (e.g. flowability).
Collapse
Affiliation(s)
- Adrian Schmidt
- Institute of Pharmaceutics and Biopharmaceutics, Heinrich-Heine-University, 40225 Duesseldorf, Germany; Novartis AG, Novartis Campus, 4002 Basel, Switzerland
| | - Hans de Waard
- Novartis AG, Novartis Campus, 4002 Basel, Switzerland
| | | | - Peter Kleinebudde
- Institute of Pharmaceutics and Biopharmaceutics, Heinrich-Heine-University, 40225 Duesseldorf, Germany
| | - Markus Krumme
- Novartis AG, Novartis Campus, 4002 Basel, Switzerland.
| |
Collapse
|
27
|
Continuous Single-Step Wet Granulation with Integrated in-Barrel-Drying. Pharm Res 2018; 35:167. [DOI: 10.1007/s11095-018-2451-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2018] [Accepted: 06/18/2018] [Indexed: 11/27/2022]
|
28
|
Twin Screw Granulation: An Investigation of the Effect of Barrel Fill Level. Pharmaceutics 2018; 10:pharmaceutics10020067. [PMID: 29857576 PMCID: PMC6027341 DOI: 10.3390/pharmaceutics10020067] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2018] [Revised: 05/17/2018] [Accepted: 05/26/2018] [Indexed: 11/17/2022] Open
Abstract
This paper focuses on investigating the influence of varying barrel fill levels on the mean residence time, granule properties (median size, size distribution, and shape), and tensile strength of tablets. Specific feed load (SFL) (powder feed rate divided by screw speed) and powder feed number (PFN) (i.e., powder mass flow rate divided by the product of screw speed, screw diameter, and the material density in the denominator) were considered as surrogates for the barrel fill level. Two type of powders (lactose and microcrystalline cellulose (MCC)) were granulated separately at varying fill levels at different liquid-to-solid ratios (L/S). It was observed that by controlling the barrel fill level, the granule size, shape, and tablet tensile strength can be maintained at specific L/S. It was also noticed that the mean residence time decreased with increasing fill levels in the case of both lactose and MCC powder. However, it was only found to be related to the change in granule size in case of granulating microcrystalline cellulose at varying fill levels. At very high fill levels, granule size decreased, owing to a limited interaction between MCC powder and liquid at high throughput force and short residence time.
Collapse
|
29
|
Nicolaï N, De Leersnyder F, Copot D, Stock M, Ionescu CM, Gernaey KV, Nopens I, De Beer T. Liquid‐to‐solid ratio control as an advanced process control solution for continuous twin‐screw wet granulation. AIChE J 2018. [DOI: 10.1002/aic.16161] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Affiliation(s)
- Niels Nicolaï
- Dept. of Pharmaceutical Analysis, Faculty of Pharmaceutical Sciences, Laboratory of Pharmaceutical Process Analytical Technology (LPPAT)Ghent University, Ottergemsesteenweg 460Ghent 9000 Belgium
- Dept. of Data Analysis and Mathematical Modelling, BIOMATH, Faculty of Bioscience EngineeringGhent University, Coupure Links 653Ghent 9000 Belgium
| | - Fien De Leersnyder
- Dept. of Pharmaceutical Analysis, Faculty of Pharmaceutical Sciences, Laboratory of Pharmaceutical Process Analytical Technology (LPPAT)Ghent University, Ottergemsesteenweg 460Ghent 9000 Belgium
| | - Dana Copot
- Dept. of Electrical Energy, Metals, Mechanical Constructions and Systems, Research Group on Dynamical Systems and ControlGhent University, Technologiepark 914Zwijnaarde 9052 Belgium
| | - Michiel Stock
- Dept. of Data Analysis and Mathematical Modelling, KERMIT, Faculty of Bioscience EngineeringGhent University, Coupure Links 653Ghent 9000 Belgium
| | - Clara M. Ionescu
- Dept. of Electrical Energy, Metals, Mechanical Constructions and Systems, Research Group on Dynamical Systems and ControlGhent University, Technologiepark 914Zwijnaarde 9052 Belgium
| | - Krist V. Gernaey
- Dept. of Chemical and Biochemical Engineering, CAPEC‐PROCESS Research CenterTechnical University of Denmark, Building 229Kgs. Lyngby 2800 Denmark
| | - Ingmar Nopens
- Dept. of Data Analysis and Mathematical Modelling, BIOMATH, Faculty of Bioscience EngineeringGhent University, Coupure Links 653Ghent 9000 Belgium
| | - Thomas De Beer
- Dept. of Pharmaceutical Analysis, Faculty of Pharmaceutical Sciences, Laboratory of Pharmaceutical Process Analytical Technology (LPPAT)Ghent University, Ottergemsesteenweg 460Ghent 9000 Belgium
| |
Collapse
|
30
|
Meier R, Moll KP, Krumme M, Kleinebudde P. Simplified, High Drug-Loaded Formulations Containing Hydrochlorothiazide for Twin-Screw Granulation. CHEM-ING-TECH 2017. [DOI: 10.1002/cite.201600134] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Robin Meier
- Heinrich Heine University; Institute of Pharmaceutics and Biopharmaceutics; Universitätsstraße 1 40225 Dusseldorf Germany
| | | | | | - Peter Kleinebudde
- Heinrich Heine University; Institute of Pharmaceutics and Biopharmaceutics; Universitätsstraße 1 40225 Dusseldorf Germany
| |
Collapse
|
31
|
Meier R, Moll KP, Krumme M, Kleinebudde P. Impact of fill-level in twin-screw granulation on critical quality attributes of granules and tablets. Eur J Pharm Biopharm 2017; 115:102-112. [DOI: 10.1016/j.ejpb.2017.02.010] [Citation(s) in RCA: 43] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2016] [Indexed: 10/20/2022]
|
32
|
Maniruzzaman M, Ross SA, Dey T, Nair A, Snowden MJ, Douroumis D. A quality by design (QbD) twin-Screw extrusion wet granulation approach for processing water insoluble drugs. Int J Pharm 2017; 526:496-505. [PMID: 28502896 DOI: 10.1016/j.ijpharm.2017.05.020] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2016] [Revised: 05/08/2017] [Accepted: 05/09/2017] [Indexed: 10/19/2022]
Abstract
In this study, a Quality by Design (QbD) approach was used to identify the effect of formulation parameters in a twin screw wet extrusion granulation process for the manufacturing of ibuprofen (IBU) granules with increased dissolution rates. A fractional factorial Design of Experiment (DoE) was used to investigate the effect of the excipient composition, binder amount and liquid to solid (L/S) ratio (independent variables) on drug dissolution rates, median particle size diameter and specific surface area (dependent variables). The intra-granular addition of the binder in inorganic/polymer blends processed with ethanol as granulating liquids facilitated the formation of granules at various particle sizes. DoE regression analysis showed that all formulation parameters affect the dependent variables significantly. The enhanced dissolution rates were attributed not only to the IBU particle size reduction and adsorption in the porous inorganic network but also to the high specific surface area of the produced granules. Dynamic vapour sorption showed increased water absorption for granules with small particle size distribution and high specific surface area.
Collapse
Affiliation(s)
- Mohammed Maniruzzaman
- Faculty of Engineering and Science, School of Science, University of Greenwich, Chatham Maritime, Chatham, Kent, ME4 4TB, UK
| | - Steven A Ross
- Faculty of Engineering and Science, School of Science, University of Greenwich, Chatham Maritime, Chatham, Kent, ME4 4TB, UK
| | - Tumpa Dey
- Faculty of Engineering and Science, School of Science, University of Greenwich, Chatham Maritime, Chatham, Kent, ME4 4TB, UK
| | - Arun Nair
- Fuji Chemical Industry Co., Ltd., 12F, The Front Tower Shiba Koen, 2-6-3 Shibakoen, Minato-Ward, Tokyo, 105-0011, Japan
| | - Martin J Snowden
- Faculty of Engineering and Science, School of Science, University of Greenwich, Chatham Maritime, Chatham, Kent, ME4 4TB, UK
| | - Dennis Douroumis
- Faculty of Engineering and Science, School of Science, University of Greenwich, Chatham Maritime, Chatham, Kent, ME4 4TB, UK.
| |
Collapse
|
33
|
Experimental determination of residence time distribution in continuous dry granulation. Int J Pharm 2017; 524:91-100. [DOI: 10.1016/j.ijpharm.2017.03.085] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2016] [Revised: 03/29/2017] [Accepted: 03/30/2017] [Indexed: 11/20/2022]
|
34
|
Van Snick B, Holman J, Cunningham C, Kumar A, Vercruysse J, De Beer T, Remon J, Vervaet C. Continuous direct compression as manufacturing platform for sustained release tablets. Int J Pharm 2017; 519:390-407. [DOI: 10.1016/j.ijpharm.2017.01.010] [Citation(s) in RCA: 74] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2016] [Revised: 01/03/2017] [Accepted: 01/04/2017] [Indexed: 10/20/2022]
|
35
|
Meier R, Moll KP, Krumme M, Kleinebudde P. How Deformation Behavior Controls Product Performance After Twin Screw Granulation With High Drug Loads and Crospovidone as Disintegrant. J Pharm Sci 2016; 106:291-301. [PMID: 27817829 DOI: 10.1016/j.xphs.2016.09.026] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2016] [Revised: 09/26/2016] [Accepted: 09/28/2016] [Indexed: 10/20/2022]
Abstract
This study addresses the quantitative influence of 12 different materials (active pharmaceutical ingredients and excipients as surrogate active pharmaceutical ingredients) on the critical quality attributes of twin screw granulated products and subsequently produced tablets. Prestudies demonstrated the significant influence of the chosen model materials (in combination with crospovidone) on the disintegration behavior of the resulting tablets, despite comparable tablet porosities. This study elucidates possible reasons for the varying disintegration behavior by investigating raw material, granule, and tablet properties. An answer could be found in the mechanical properties of the raw materials and the produced granules. Through compressibility studies, the materials could be classified into materials with high compressibility, which deform rather plastically under compression stress, and low compressibility, which display breakages under compression stress. In general, and apart from (pseudo)-polymorphic transformations, brittle materials featured excellent disintegration performance, even at low resulting tablet porosities <8%, whereas plastically deformable materials mostly did not reveal any disintegration. These findings must be considered in the development of simplified formulations with high drug loads, in which the active pharmaceutical ingredient predominantly defines the deformation behavior of the granule.
Collapse
Affiliation(s)
- Robin Meier
- Institute of Pharmaceutics and Biopharmaceutics, Heinrich Heine University, Universitaetsstr. 1, Duesseldorf 40225, Germany
| | | | | | - Peter Kleinebudde
- Institute of Pharmaceutics and Biopharmaceutics, Heinrich Heine University, Universitaetsstr. 1, Duesseldorf 40225, Germany.
| |
Collapse
|