1
|
Ladd ME, Quick HH, Speck O, Bock M, Doerfler A, Forsting M, Hennig J, Ittermann B, Möller HE, Nagel AM, Niendorf T, Remy S, Schaeffter T, Scheffler K, Schlemmer HP, Schmitter S, Schreiber L, Shah NJ, Stöcker T, Uder M, Villringer A, Weiskopf N, Zaiss M, Zaitsev M. Germany's journey toward 14 Tesla human magnetic resonance. MAGMA (NEW YORK, N.Y.) 2023; 36:191-210. [PMID: 37029886 PMCID: PMC10140098 DOI: 10.1007/s10334-023-01085-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Revised: 03/23/2023] [Accepted: 03/27/2023] [Indexed: 04/09/2023]
Abstract
Multiple sites within Germany operate human MRI systems with magnetic fields either at 7 Tesla or 9.4 Tesla. In 2013, these sites formed a network to facilitate and harmonize the research being conducted at the different sites and make this technology available to a larger community of researchers and clinicians not only within Germany, but also worldwide. The German Ultrahigh Field Imaging (GUFI) network has defined a strategic goal to establish a 14 Tesla whole-body human MRI system as a national research resource in Germany as the next progression in magnetic field strength. This paper summarizes the history of this initiative, the current status, the motivation for pursuing MR imaging and spectroscopy at such a high magnetic field strength, and the technical and funding challenges involved. It focuses on the scientific and science policy process from the perspective in Germany, and is not intended to be a comprehensive systematic review of the benefits and technical challenges of higher field strengths.
Collapse
Affiliation(s)
- Mark E Ladd
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg, Germany.
- Faculty of Medicine, Heidelberg University, Heidelberg, Germany.
- Faculty of Physics and Astronomy, Heidelberg University, Heidelberg, Germany.
- Erwin L. Hahn Institute for MRI, University of Duisburg-Essen, Essen, Germany.
| | - Harald H Quick
- Erwin L. Hahn Institute for MRI, University of Duisburg-Essen, Essen, Germany
- High-Field and Hybrid MR Imaging, University Hospital Essen, Essen, Germany
| | - Oliver Speck
- Department of Biomedical Magnetic Resonance, Otto von Guericke University Magdeburg, Magdeburg, Germany
- German Center for Neurodegenerative Diseases (DZNE), Magdeburg, Germany
- Center for Behavioural Brain Sciences, Magdeburg, Germany
- Leibniz Institute for Neurobiology (LIN), Magdeburg, Germany
| | - Michael Bock
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, Faculty of Medicine, Medical Center, University of Freiburg, Freiburg, Germany
| | - Arnd Doerfler
- Department of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander University Erlangen-Nuremberg (FAU), Erlangen, Germany
| | - Michael Forsting
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Jürgen Hennig
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, Faculty of Medicine, Medical Center, University of Freiburg, Freiburg, Germany
| | - Bernd Ittermann
- Medical Physics and Metrological Information Technology, Physikalisch-Technische Bundesanstalt (PTB), Berlin, Germany
| | - Harald E Möller
- Methods and Development Group Nuclear Magnetic Resonance, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | - Armin M Nagel
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg, Germany
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander University Erlangen-Nuremberg (FAU), Erlangen, Germany
| | - Thoralf Niendorf
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Stefan Remy
- German Center for Neurodegenerative Diseases (DZNE), Magdeburg, Germany
- Leibniz Institute for Neurobiology (LIN), Magdeburg, Germany
| | - Tobias Schaeffter
- Medical Physics and Metrological Information Technology, Physikalisch-Technische Bundesanstalt (PTB), Berlin, Germany
| | - Klaus Scheffler
- Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Department of Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany
| | | | - Sebastian Schmitter
- Medical Physics and Metrological Information Technology, Physikalisch-Technische Bundesanstalt (PTB), Berlin, Germany
| | - Laura Schreiber
- Department of Cardiovascular Imaging, Comprehensive Heart Failure Center, University Hospital Würzburg, Würzburg, Germany
| | - N Jon Shah
- Institute of Neuroscience and Medicine - 4, Forschungszentrum Jülich, Jülich, Germany
| | - Tony Stöcker
- MR Physics, German Center for Neurodegenerative Diseases (DZNE), Bonn, Germany
| | - Michael Uder
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander University Erlangen-Nuremberg (FAU), Erlangen, Germany
| | - Arno Villringer
- Department of Neurology, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | - Nikolaus Weiskopf
- Department of Neurophysics, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
- Felix Bloch Institute for Solid State Physics, Faculty of Physics and Earth Sciences, Leipzig University, Leipzig, Germany
| | - Moritz Zaiss
- Department of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander University Erlangen-Nuremberg (FAU), Erlangen, Germany
| | - Maxim Zaitsev
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, Faculty of Medicine, Medical Center, University of Freiburg, Freiburg, Germany
| |
Collapse
|
2
|
Nagururu NV, Akbar A, Ward BK. Using magnetic resonance imaging to improve diagnosis of peripheral vestibular disorders. J Neurol Sci 2022; 439:120300. [DOI: 10.1016/j.jns.2022.120300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 05/18/2022] [Accepted: 05/23/2022] [Indexed: 12/01/2022]
|
3
|
Hansson B, Markenroth Bloch K, Owman T, Nilsson M, Lätt J, Olsrud J, Björkman-Burtscher IM. Subjectively Reported Effects Experienced in an Actively Shielded 7T MRI: A Large-Scale Study. J Magn Reson Imaging 2020; 52:1265-1276. [PMID: 32196818 DOI: 10.1002/jmri.27139] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2019] [Revised: 03/03/2020] [Accepted: 03/03/2020] [Indexed: 12/22/2022] Open
Abstract
BACKGROUND Ultrahigh-field (UHF) MRI advances towards clinical use. Patient compliance is generally high, but few large-scale studies have investigated the effects experienced in 7T MRI systems, especially considering peripheral nerve stimulation (PNS) and caregiving. PURPOSE To evaluate the quantity, the intensity, and subjective experiences from short-term effects, focusing on the levels of comfort and compliance of subjects. STUDY TYPE Prospective. POPULATION In all, 954 consecutive MRIs in 801 subjects for 3 years. FIELD STRENGTH 7T. ASSESSMENT After the 7T examination, a questionnaire was used to collect data. STATISTICAL TESTS Descriptive statistics, Spearman's rank correlation, Mann-Whitney U-test, and t-test. RESULTS The majority (63%) of subjects agreed that the MRI experience was comfortable and 93% would be willing to undergo future 7T MRI as a patient (5% undecided) and 82% for research purposes (12% undecided). The most common short-term effects experienced were dizziness (81%), inconsistent movement (68%), PNS (63%), headache (40%), nausea (32%), metallic taste (12%), and light flashes (8%). Of the subjects who reported having PNS (n = 603), 44% experienced PNS as "not uncomfortable at all," 45% as "little or very little uncomfortable," and 11% as "moderate to very much uncomfortable." Scanner room temperature was experienced more comfortable before (78%) than during (58%) examinations, and the noise level was acceptable by 90% of subjects. Anxiety before the examination was reported by 43%. Patients differed from healthy volunteers regarding an experience of headache, metallic taste, dizziness, or anxiety. Room for improvement was pointed out after 117 examinations concerning given information (n = 73), communication and sound system (n = 35), or nursing care (n = 15). DATA CONCLUSION Subjectively reported effects occur in actively shielded 7T MRI and include physiological responses and individual psychological issues. Although leaving room for improvement, few subjects experienced these effects being so uncomfortable that they would lead to aversion to future UHF examinations. LEVEL OF EVIDENCE 1 TECHNICAL EFFICACY: Stage 5 J. Magn. Reson. Imaging 2020;52:1265-1276.
Collapse
Affiliation(s)
- Boel Hansson
- Department of Medical Imaging and Physiology, Skåne University Hospital, Lund, Sweden.,Department of Diagnostic Radiology, Clinical Sciences, Lund University, Lund, Sweden
| | | | - Titti Owman
- Department of Medical Imaging and Physiology, Skåne University Hospital, Lund, Sweden.,Department of Diagnostic Radiology, Clinical Sciences, Lund University, Lund, Sweden
| | - Markus Nilsson
- Department of Diagnostic Radiology, Clinical Sciences, Lund University, Lund, Sweden
| | - Jimmy Lätt
- Department of Medical Imaging and Physiology, Skåne University Hospital, Lund, Sweden
| | - Johan Olsrud
- Department of Diagnostic Radiology, Clinical Sciences, Lund University, Lund, Sweden
| | - Isabella M Björkman-Burtscher
- Department of Medical Imaging and Physiology, Skåne University Hospital, Lund, Sweden.,Department of Diagnostic Radiology, Clinical Sciences, Lund University, Lund, Sweden.,Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| |
Collapse
|
4
|
Hansson B, Höglund P, Markenroth Bloch K, Nilsson M, Olsrud J, Wilén J, Björkman-Burtscher IM. Short-term effects experienced during examinations in an actively shielded 7 T MR. Bioelectromagnetics 2019; 40:234-249. [PMID: 30920671 PMCID: PMC6593459 DOI: 10.1002/bem.22189] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2018] [Accepted: 03/12/2019] [Indexed: 01/18/2023]
Abstract
The objective of this study was to evaluate occurrence and strength of short-term effects experienced by study participants in an actively shielded (AS) 7 tesla (7 T) magnetic resonance (MR) scanner, to compare results with earlier reports on passively shielded (PS) 7 T MR scanners, and to outline possible healthcare strategies to improve patient compliance. Study participants (n = 124) completed a web-based questionnaire directly after being examined in an AS 7 T MR (n = 154 examinations). Most frequently experienced short-term effects were dizziness (84%) and inconsistent movement (70%), especially while moving into or out of the magnet. Peripheral nerve stimulation (PNS)-twitching-was experienced in 67% of research examinations and showed a dependence between strength of twitches and recorded predicted PNS values. Of the participants, 74% experienced noise levels as acceptable and the majority experienced body and room temperature as comfortable. Of the study participants, 95% felt well-informed and felt they had had good contact with the staff before the examination. Willingness to undergo a future 7 T examination was high (>90%). Our study concludes short-term effects are often experienced during examinations in an AS 7 T MR, leaving room for improvement in nursing care strategies to increase patient compliance. Bioelectromagnetics. 2019;9999:XX-XX. © 2019 The Authors. Bioelectromagnetics Published by Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Boel Hansson
- Department of Diagnostic Radiology, Skåne University Hospital, Lund, Sweden.,Department of Diagnostic Radiology, Clinical Sciences, Lund University, Lund, Sweden
| | - Peter Höglund
- Department of Clinical Pharmacology, Lund University, Lund, Sweden
| | | | - Markus Nilsson
- Department of Diagnostic Radiology, Clinical Sciences, Lund University, Lund, Sweden
| | - Johan Olsrud
- Department of Diagnostic Radiology, Skåne University Hospital, Lund, Sweden.,Department of Diagnostic Radiology, Clinical Sciences, Lund University, Lund, Sweden
| | - Jonna Wilén
- Department of Radiation Sciences, Umeå University, Umeå, Sweden
| | - Isabella M Björkman-Burtscher
- Department of Diagnostic Radiology, Skåne University Hospital, Lund, Sweden.,Department of Diagnostic Radiology, Clinical Sciences, Lund University, Lund, Sweden.,Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| |
Collapse
|
5
|
Ladd ME, Bachert P, Meyerspeer M, Moser E, Nagel AM, Norris DG, Schmitter S, Speck O, Straub S, Zaiss M. Pros and cons of ultra-high-field MRI/MRS for human application. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2018; 109:1-50. [PMID: 30527132 DOI: 10.1016/j.pnmrs.2018.06.001] [Citation(s) in RCA: 275] [Impact Index Per Article: 45.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2018] [Revised: 06/06/2018] [Accepted: 06/07/2018] [Indexed: 05/08/2023]
Abstract
Magnetic resonance imaging and spectroscopic techniques are widely used in humans both for clinical diagnostic applications and in basic research areas such as cognitive neuroimaging. In recent years, new human MR systems have become available operating at static magnetic fields of 7 T or higher (≥300 MHz proton frequency). Imaging human-sized objects at such high frequencies presents several challenges including non-uniform radiofrequency fields, enhanced susceptibility artifacts, and higher radiofrequency energy deposition in the tissue. On the other side of the scale are gains in signal-to-noise or contrast-to-noise ratio that allow finer structures to be visualized and smaller physiological effects to be detected. This review presents an overview of some of the latest methodological developments in human ultra-high field MRI/MRS as well as associated clinical and scientific applications. Emphasis is given to techniques that particularly benefit from the changing physical characteristics at high magnetic fields, including susceptibility-weighted imaging and phase-contrast techniques, imaging with X-nuclei, MR spectroscopy, CEST imaging, as well as functional MRI. In addition, more general methodological developments such as parallel transmission and motion correction will be discussed that are required to leverage the full potential of higher magnetic fields, and an overview of relevant physiological considerations of human high magnetic field exposure is provided.
Collapse
Affiliation(s)
- Mark E Ladd
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany; Faculty of Medicine, University of Heidelberg, Heidelberg, Germany; Faculty of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany; Erwin L. Hahn Institute for MRI, University of Duisburg-Essen, Essen, Germany.
| | - Peter Bachert
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany; Faculty of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany.
| | - Martin Meyerspeer
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria; MR Center of Excellence, Medical University of Vienna, Vienna, Austria.
| | - Ewald Moser
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria; MR Center of Excellence, Medical University of Vienna, Vienna, Austria.
| | - Armin M Nagel
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany; Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
| | - David G Norris
- Donders Institute for Brain, Cognition and Behaviour, Radboud University Nijmegen, Nijmegen, Netherlands; Erwin L. Hahn Institute for MRI, University of Duisburg-Essen, Essen, Germany.
| | - Sebastian Schmitter
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany; Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany.
| | - Oliver Speck
- Department of Biomedical Magnetic Resonance, Otto-von-Guericke-University Magdeburg, Magdeburg, Germany; German Center for Neurodegenerative Diseases, Magdeburg, Germany; Center for Behavioural Brain Sciences, Magdeburg, Germany; Leibniz Institute for Neurobiology, Magdeburg, Germany.
| | - Sina Straub
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany.
| | - Moritz Zaiss
- High-Field Magnetic Resonance Center, Max-Planck-Institute for Biological Cybernetics, Tübingen, Germany.
| |
Collapse
|
6
|
Subjective perception of safety in healthy individuals working with 7 T MRI scanners: a retrospective multicenter survey. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2016; 29:379-87. [DOI: 10.1007/s10334-016-0527-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/06/2015] [Revised: 01/14/2016] [Accepted: 01/15/2016] [Indexed: 10/22/2022]
|
7
|
Abstract
Ideally, vestibular pharmacotherapy is intended, through specific and targeted molecular actions, to significantly alleviate vertigo symptoms, to protect or repair the vestibular sensory network under pathologic conditions, and to promote vestibular compensation, with the eventual aim of improving the patient's quality of life. In fact, in order to achieve this aim, considerable progress still needs to be made. The lack of information on the etiology of vestibular disorders and the pharmacologic targets to modulate, as well as the technical challenge of targeting a drug to its effective site are some of the main issues yet to be overcome. In this review, my intention is to provide an account of the therapeutic principles that have shaped current vestibular pharmacotherapy and to further explore crucial questions that must be taken into consideration in order to develop targeted and specific pharmacologic therapies for each type and stage of vestibular disorders.
Collapse
Affiliation(s)
- C Chabbert
- Integrative and Adaptative Neurosciences, University of Aix Marseille, Marseille, France.
| |
Collapse
|
8
|
Gorlin A, Hoxworth JM, Pavlicek W, Thunberg CA, Seamans D. Acute vertigo in an anesthesia provider during exposure to a 3T MRI scanner. MEDICAL DEVICES-EVIDENCE AND RESEARCH 2015; 8:161-6. [PMID: 25792858 PMCID: PMC4362897 DOI: 10.2147/mder.s76474] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022] Open
Abstract
Vertigo induced by exposure to the magnetic field of a magnetic resonance imaging (MRI) scanner is a well-known phenomenon within the radiology community but is not widely appreciated by other clinical specialists. Here, we describe a case of an anesthetist experiencing acute vertigo while providing sedation to a patient undergoing a 3 Tesla MRI scan. After discussing previous reports, and the evidence surrounding MRI-induced vertigo, we review potential etiologies that include the effects of both static and time-varying magnetic fields on the vestibular apparatus. We conclude our review by discussing the occupational standards that exist for MRI exposure and methods to minimize the risks of MRI-induced vertigo for clinicians working in the MRI environment.
Collapse
Affiliation(s)
- Andrew Gorlin
- Department of Anesthesiology, Mayo Clinic Arizona, Phoenix, AZ, USA
| | | | | | | | - David Seamans
- Department of Anesthesiology, Mayo Clinic Arizona, Phoenix, AZ, USA
| |
Collapse
|
9
|
Klix S, Els A, Paul K, Graessl A, Oezerdem C, Weinberger O, Winter L, Thalhammer C, Huelnhagen T, Rieger J, Mehling H, Schulz-Menger J, Niendorf T. On the subjective acceptance during cardiovascular magnetic resonance imaging at 7.0 Tesla. PLoS One 2015; 10:e0117095. [PMID: 25621491 PMCID: PMC4306482 DOI: 10.1371/journal.pone.0117095] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2014] [Accepted: 12/18/2014] [Indexed: 12/25/2022] Open
Abstract
PURPOSE This study examines the subjective acceptance during UHF-CMR in a cohort of healthy volunteers who underwent a cardiac MR examination at 7.0T. METHODS Within a period of two-and-a-half years (January 2012 to June 2014) a total of 165 healthy volunteers (41 female, 124 male) without any known history of cardiac disease underwent UHF-CMR. For the assessment of the subjective acceptance a questionnaire was used to examine the participants experience prior, during and after the UHF-CMR examination. For this purpose, subjects were asked to respond to the questionnaire in an exit interview held immediately after the completion of the UHF-CMR examination under supervision of a study nurse to ensure accurate understanding of the questions. All questions were answered with "yes" or "no" including space for additional comments. RESULTS Transient muscular contraction was documented in 12.7% of the questionnaires. Muscular contraction was reported to occur only during periods of scanning with the magnetic field gradients being rapidly switched. Dizziness during the study was reported by 12.7% of the subjects. Taste of metal was reported by 10.1% of the study population. Light flashes were reported by 3.6% of the entire cohort. 13% of the subjects reported side effects/observations which were not explicitly listed in the questionnaire but covered by the question about other side effects. No severe side effects as vomiting or syncope after scanning occurred. No increase in heart rate was observed during the UHF-CMR exam versus the baseline clinical examination. CONCLUSIONS This study adds to the literature by detailing the subjective acceptance of cardiovascular magnetic resonance imaging examinations at a magnetic field strength of 7.0T. Cardiac MR examinations at 7.0T are well tolerated by healthy subjects. Broader observational and multi-center studies including patient cohorts with cardiac diseases are required to gain further insights into the subjective acceptance of UHF-CMR examinations.
Collapse
Affiliation(s)
- Sabrina Klix
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max-Delbrueck-Center for Molecular Medicine, Berlin, Germany
| | - Antje Els
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max-Delbrueck-Center for Molecular Medicine, Berlin, Germany
| | - Katharina Paul
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max-Delbrueck-Center for Molecular Medicine, Berlin, Germany
| | - Andreas Graessl
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max-Delbrueck-Center for Molecular Medicine, Berlin, Germany
| | - Celal Oezerdem
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max-Delbrueck-Center for Molecular Medicine, Berlin, Germany
| | - Oliver Weinberger
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max-Delbrueck-Center for Molecular Medicine, Berlin, Germany
| | - Lukas Winter
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max-Delbrueck-Center for Molecular Medicine, Berlin, Germany
| | - Christof Thalhammer
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max-Delbrueck-Center for Molecular Medicine, Berlin, Germany
| | - Till Huelnhagen
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max-Delbrueck-Center for Molecular Medicine, Berlin, Germany
| | - Jan Rieger
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max-Delbrueck-Center for Molecular Medicine, Berlin, Germany
| | - Heidrun Mehling
- Experimental and Clinical Research Center (ECRC), a joint cooperation between the Charité Medical Faculty and the Max-Delbrueck-Center for Molecular Medicine, Berlin, Germany
| | - Jeanette Schulz-Menger
- Experimental and Clinical Research Center (ECRC), a joint cooperation between the Charité Medical Faculty and the Max-Delbrueck-Center for Molecular Medicine, Berlin, Germany
- HELIOS Klinikum Berlin-Buch, Dept. of Cardiology and Nephrology, 13125 Berlin, Germany
| | - Thoralf Niendorf
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max-Delbrueck-Center for Molecular Medicine, Berlin, Germany
- Experimental and Clinical Research Center (ECRC), a joint cooperation between the Charité Medical Faculty and the Max-Delbrueck-Center for Molecular Medicine, Berlin, Germany
| |
Collapse
|
10
|
Friebe B, Wollrab A, Thormann M, Fischbach K, Ricke J, Grueschow M, Kropf S, Fischbach F, Speck O. Sensory perceptions of individuals exposed to the static field of a 7T MRI: A controlled blinded study. J Magn Reson Imaging 2014; 41:1675-81. [PMID: 25236353 DOI: 10.1002/jmri.24748] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2014] [Accepted: 07/21/2014] [Indexed: 12/16/2022] Open
Abstract
PURPOSE To determine the subjective experience of subjects undergoing 7T magnetic resonance imaging (MRI) compared to a mock scanner with no magnetic field. METHODS AND MATERIALS In all, 44 healthy subjects were exposed to both the B0 field of a 7T whole-body MRI and a realistic mock scanner with no magnetic field. Subjects were blinded to the actual field strength and no scanning was performed. After exposure, subjects rated their experience of potential sensory perceptions. RESULTS The most frequently observed side effect was vertigo while entering the gantry, which was reported by 38.6% (n = 17). Other frequent side effects were the appearance of phosphenes (18.2%, n = 8), thermal heat sensation (15.9%), unsteady gait after exposure (13.6%, n = 6), and dizziness (13.6%). All side effects were reported significantly more often after 7T exposure. Nine subjects (20.5%) did not report any sensory perceptions at all, ie, neither in the 7T scanner nor in the mock scanner. CONCLUSION Light, acute, and transient sensory perceptions can occur in subjects undergoing ultrahighfield MRI, of which vertigo seems to be the most frequently reported. Possible psychological effects might contribute to the emergence of such sensory perceptions, as some subjects also reported them to appear in a realistic mock scanner with no magnetic field.
Collapse
Affiliation(s)
- Björn Friebe
- Department of Radiology and Nuclear Medicine, Otto-von-Guericke University Magdeburg, Germany
| | - Astrid Wollrab
- Department of Biomedical Magnetic Resonance (BMMR), Division Experimental Physics, Faculty of Physics, Otto-von-Guericke University Magdeburg, Germany
| | - Markus Thormann
- Department of Radiology and Nuclear Medicine, Otto-von-Guericke University Magdeburg, Germany
| | - Katharina Fischbach
- Department of Radiology and Nuclear Medicine, Otto-von-Guericke University Magdeburg, Germany
| | - Jens Ricke
- Department of Radiology and Nuclear Medicine, Otto-von-Guericke University Magdeburg, Germany
| | | | - Siegfried Kropf
- Institute for Biometrics and Biomedical Informatics, Otto-von-Guericke University Magdeburg, Germany
| | - Frank Fischbach
- Department of Radiology and Nuclear Medicine, Otto-von-Guericke University Magdeburg, Germany
| | - Oliver Speck
- Department of Biomedical Magnetic Resonance (BMMR), Division Experimental Physics, Faculty of Physics, Otto-von-Guericke University Magdeburg, Germany
- Leibniz Institute for Neurobiology, Magdeburg, Germany
| |
Collapse
|
11
|
Theysohn JM, Kraff O, Eilers K, Andrade D, Gerwig M, Timmann D, Schmitt F, Ladd ME, Ladd SC, Bitz AK. Vestibular effects of a 7 Tesla MRI examination compared to 1.5 T and 0 T in healthy volunteers. PLoS One 2014; 9:e92104. [PMID: 24658179 PMCID: PMC3962400 DOI: 10.1371/journal.pone.0092104] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2014] [Accepted: 02/18/2014] [Indexed: 11/18/2022] Open
Abstract
Ultra-high-field MRI (7 Tesla (T) and above) elicits more temporary side-effects compared to 1.5 T and 3 T, e.g. dizziness or “postural instability” even after exiting the scanner. The current study aims to assess quantitatively vestibular performance before and after exposure to different MRI scenarios at 7 T, 1.5 T and 0 T. Sway path and body axis rotation (Unterberger's stepping test) were quantitatively recorded in a total of 46 volunteers before, 2 minutes after, and 15 minutes after different exposure scenarios: 7 T head MRI (n = 27), 7 T no RF (n = 22), 7 T only B0 (n = 20), 7 T in & out B0 (n = 20), 1.5 T no RF (n = 20), 0 T (n = 15). All exposure scenarios lasted 30 minutes except for brief one minute exposure in 7 T in & out B0. Both measures were documented utilizing a 3D ultrasound system. During sway path evaluation, the experiment was repeated with eyes both open and closed. Sway paths for all long-lasting 7 T scenarios (normal, no RF, only B0) with eyes closed were significantly prolonged 2 minutes after exiting the scanner, normalizing after 15 minutes. Brief exposure to 7 T B0 or 30 minutes exposure to 1.5 T or 0 T did not show significant changes. End positions after Unterberger's stepping test were significantly changed counter-clockwise after all 7 T scenarios, including the brief in & out B0 exposure. Shorter exposure resulted in a smaller alteration angle. In contrast to sway path, reversal of changes in body axis rotation was incomplete after 15 minutes. 1.5 T caused no rotational changes. The results show that exposure to the 7 Tesla static magnetic field causes only a temporary dysfunction or “over-compensation” of the vestibular system not measurable at 1.5 or 0 Tesla. Radiofrequency fields, gradient switching, and orthostatic dysregulation do not seem to play a role.
Collapse
Affiliation(s)
- Jens M. Theysohn
- Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen, Germany
- Institute for Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
- * E-mail:
| | - Oliver Kraff
- Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen, Germany
- Institute for Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Kristina Eilers
- Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen, Germany
- Institute for Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Dorian Andrade
- Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen, Germany
- Institute for Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Marcus Gerwig
- Department of Neurology, University Hospital Essen, Essen, Germany
| | - Dagmar Timmann
- Department of Neurology, University Hospital Essen, Essen, Germany
| | | | - Mark E. Ladd
- Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen, Germany
- Division of Medical Physics in Radiology (E020), German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Susanne C. Ladd
- Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen, Germany
- Institute for Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Andreas K. Bitz
- Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen, Germany
- Division of Medical Physics in Radiology (E020), German Cancer Research Center (DKFZ), Heidelberg, Germany
| |
Collapse
|