1
|
Veluponnar D, Dashtbozorg B, Guimaraes MDS, Peeters MJTFDV, de Boer LL, Ruers TJM. Resection Ratios and Tumor Eccentricity in Breast-Conserving Surgery Specimens for Surgical Accuracy Assessment. Cancers (Basel) 2024; 16:1813. [PMID: 38791892 PMCID: PMC11119905 DOI: 10.3390/cancers16101813] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2024] [Revised: 04/30/2024] [Accepted: 05/02/2024] [Indexed: 05/26/2024] Open
Abstract
This study aims to evaluate several defined specimen parameters that would allow to determine the surgical accuracy of breast-conserving surgeries (BCS) in a representative population of patients. These specimen parameters could be used to compare surgical accuracy when using novel technologies for intra-operative BCS guidance in the future. Different specimen parameters were determined among 100 BCS patients, including the ratio of specimen volume to tumor volume (resection ratio) with different optimal margin widths (0 mm, 1 mm, 2 mm, and 10 mm). Furthermore, the tumor eccentricity [maximum tumor-margin distance - minimum tumor-margin distance] and the relative tumor eccentricity [tumor eccentricity ÷ pathological tumor diameter] were determined. Different patient subgroups were compared using Wilcoxon rank sum tests. When using a surgical margin width of 0 mm, 1 mm, 2 mm, and 10 mm, on average, 19.16 (IQR 44.36), 9.94 (IQR 18.09), 6.06 (IQR 9.69) and 1.35 (IQR 1.78) times the ideal resection volume was excised, respectively. The median tumor eccentricity among the entire patient population was 11.29 mm (SD = 3.99) and the median relative tumor eccentricity was 0.66 (SD = 2.22). Resection ratios based on different optimal margin widths (0 mm, 1 mm, 2 mm, and 10 mm) and the (relative) tumor eccentricity could be valuable outcome measures to evaluate the surgical accuracy of novel technologies for intra-operative BCS guidance.
Collapse
Affiliation(s)
- Dinusha Veluponnar
- Department of Surgery, Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam, The Netherlands
- Department of Nanobiophysics, Faculty of Science and Technology, University of Twente, Drienerlolaan 5, 7522 NB Enschede, The Netherlands
| | - Behdad Dashtbozorg
- Department of Surgery, Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam, The Netherlands
| | - Marcos Da Silva Guimaraes
- Department of Pathology, Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam, The Netherlands
| | - Marie-Jeanne T. F. D. Vrancken Peeters
- Department of Surgery, Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam, The Netherlands
- Department of Surgery, Amsterdam University Medical Center, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands
| | - Lisanne L. de Boer
- Department of Surgery, Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam, The Netherlands
| | - Theo J. M. Ruers
- Department of Surgery, Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam, The Netherlands
- Department of Nanobiophysics, Faculty of Science and Technology, University of Twente, Drienerlolaan 5, 7522 NB Enschede, The Netherlands
| |
Collapse
|
2
|
Pantiora E, Jazrawi A, Hersi AF, Abdsaleh S, Ahlstedt H, Molnar E, Wärnberg F, Eriksson S, Karakatsanis A. Magnetic Seed vs Guidewire Breast Cancer Localization With Magnetic Lymph Node Detection: A Randomized Clinical Trial. JAMA Surg 2024; 159:239-246. [PMID: 38150215 PMCID: PMC10753436 DOI: 10.1001/jamasurg.2023.6520] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Accepted: 09/09/2023] [Indexed: 12/28/2023]
Abstract
Importance Guidewires have been the standard for breast lesion localization but pose operative and logistic challenges. Paramagnetic seeds have shown promising results, but to the authors' knowledge, no randomized comparison has been performed. Objective To determine whether the combination of a paramagnetic seed and superparamagnetic iron oxide (SPIO) is equivalent to guidewire and SPIO for breast cancer localization and sentinel lymph node detection (SLND). Design, Setting, and Participants This was a phase 3, pragmatic, equivalence, 2-arm, open-label, randomized clinical trial conducted at 3 university and/or community hospitals in Sweden from May 2018 to May 2022. Included in the study were patients with early breast cancer planned for breast conservation and SLND. Study data were analyzed July to November 2022. Interventions Participants were randomly assigned 1:1 to a paramagnetic seed or a guidewire. All patients underwent SLND with SPIO. Main Outcomes and Measures Re-excision rate and resection ratio (defined as actual resection volume / optimal resection volume). Results A total of 426 women (median [IQR] age, 65 [56-71] years; median [IQR] tumor size, 11 [8-15] mm) were included in the study. The re-excision rate was 2.90% (95% CI, 1.60%-4.80%), and the median (IQR) resection ratio was 1.96 (1.15-3.44). No differences were found between the guidewire and the seed in re-excisions (6 of 211 [2.84%] vs 6 of 209 [2.87%]; difference, -0.03%; 95% CI, -3.20% to 3.20%; P = .99) or resection ratio (median, 1.93; IQR, 1.18-3.43 vs median, 2.01; IQR, 1.11-3.47; P = .70). Overall SLN detection was 98.6% (95% CI, 97.1%-99.4%) with no differences between arms (203 of 207 [98.1%] vs 204 of 206 [99.0%]; difference, -0.9%; 95% CI, -3.6% to 1.8%; P = .72). More failed localizations occurred with the guidewire (21 of 208 [10.1%] vs 4 of 215 [1.9%]; difference, 8.2%; 95% CI, 3.3%-13.2%; P < .001). Median (IQR) time to specimen excision was shorter for the seed (15 [10-22] minutes vs 18 [12-30] minutes; P = .01), as was the total operative time (69 [56-86] minutes vs 75.5 [59-101] minutes; P = .03). The experience of surgeons, radiologists, and surgical coordinators was better with the seed. Conclusions and Relevance The combination of SPIO and a paramagnetic seed performed comparably with SPIO and guidewire for breast cancer conserving surgery and resulted in more successful localizations, shorter operative times, and better experience. Trial Registration ISRCTN.org Identifier: ISRCTN11914537.
Collapse
Affiliation(s)
- Eirini Pantiora
- Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
- Section for Breast Surgery, Department of Surgery, Uppsala University Hospital, Uppsala, Sweden
| | - Allan Jazrawi
- Center for Clinical Research, Department of Surgical Sciences, Uppsala University, Västerås, Sweden
- Section for Breast Surgery, Department of Surgery, Västmanlands County Hospital, Västerås, Sweden
| | - Abdi-Fatah Hersi
- Center for Clinical Research, Department of Surgical Sciences, Uppsala University, Västerås, Sweden
- Section for Breast Surgery, Department of Surgery, Västmanlands County Hospital, Västerås, Sweden
| | - Shahin Abdsaleh
- Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
- Evidia Mammography Department, Uppsala, Sweden
| | - Hanna Ahlstedt
- Department of Breast Radiology, Division of Radiology, Västmanlands County Hospital, Västerås, Sweden
| | - Eva Molnar
- Department for Breast Radiology, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Fredrik Wärnberg
- Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
- Section for Breast Surgery, Department of Surgery, Uppsala University Hospital, Uppsala, Sweden
- Sahlgrenska Center for Cancer Research, Department of Surgery, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Department of Surgery, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Staffan Eriksson
- Center for Clinical Research, Department of Surgical Sciences, Uppsala University, Västerås, Sweden
- Section for Breast Surgery, Department of Surgery, Västmanlands County Hospital, Västerås, Sweden
| | - Andreas Karakatsanis
- Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
- Section for Breast Surgery, Department of Surgery, Uppsala University Hospital, Uppsala, Sweden
| |
Collapse
|
3
|
Esgueva AJ, Sobrido C, Diaz-Botero S, Díez-Uriel E, Iscar T, De Miguel V, Regojo A, Rubio IT. Intraoperative ultrasound margin evaluation as a tool to reduce positive superficial margins in nipple and skin sparing mastectomy in breast cancer patients. EUROPEAN JOURNAL OF SURGICAL ONCOLOGY 2023; 49:107049. [PMID: 37660517 DOI: 10.1016/j.ejso.2023.107049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2023] [Accepted: 08/27/2023] [Indexed: 09/05/2023]
Abstract
BACKGROUND Intraoperative ultrasound (IOUS) guided conservative surgery has been shown to reduce rates of positive margins in breast cancer. The aim of the study is to evaluate the feasibility of using IOUS to assess superficial/anterior margins in nipple and skin sparing mastectomy (NSM/SSM) and its impact on reducing rates of positive margins. METHODS This prospective study includes all breast cancer patients who had an indication for NSM/SSM at our Institution. Superficial margin width was measured by IOUS before surgery and the area marked on the skin. Same measurement was performed afterwards in the mastectomy specimen. Any superficial margin < 5 mm was re-excised intraoperatively following the mark on the skin. RESULTS Fifty-nine patients were included, 47 patients (79.7%) underwent NSM, and 12 patients (20.3%) a SSM. Of the 59 patients, 23 (38.98%) had margins ≥5 mm and 36 patients (61.02%) had margins of ≤5 mm. Of the 36 patients with superficial margins ≤5 mm, 20 had margins <2 mm, and 6 of them had intraoperative involved superficial margins in final pathology. However, after IOUS-guided re-excision, final pathology showed no involved margins. A 2 mm margin was set as the cut-off point for performing an intraoperative re-excision. IOUS guided re-excisions for intraoperative margins ≤2 mm significantly reduced the risk of close/positive margins in final pathology, p < 0.0001. CONCLUSION The results showed that IOUS margin evaluation significantly reduced the rate of superficial positive margins in NSM/SSM. It is feasible and effective and may avoid challenging reoperations and/or additional radiation therapy for positive margins.
Collapse
Affiliation(s)
- Antonio J Esgueva
- Department of Breast Surgical Oncology, Clinica Universidad de Navarra, Universidad de Navarra, Marquesado de Santa Marta 1, Madrid, 28027, Spain
| | - Carolina Sobrido
- Breast Imaging Unit, Department of Radiology, Clinica Universidad de Navarra, Universidad de Navarra, Marquesado de Santa Marta 1, Madrid, 28027, Spain
| | - Sebastián Diaz-Botero
- Department of Breast Surgical Oncology, Clinica Universidad de Navarra, Universidad de Navarra, Marquesado de Santa Marta 1, Madrid, 28027, Spain
| | - Elena Díez-Uriel
- Breast Imaging Unit, Department of Radiology, Clinica Universidad de Navarra, Universidad de Navarra, Marquesado de Santa Marta 1, Madrid, 28027, Spain
| | - Teresa Iscar
- Department of Pathology, Clinica Universidad de Navarra, Universidad de Navarra, Marquesado de Santa Marta 1, Madrid, 28027, Spain
| | - Virginia De Miguel
- Department of Nursing, Breast Surgical Oncology, Clinica Universidad de Navarra, Universidad de Navarra, Marquesado de Santa Marta 1, Madrid, 28027, Spain
| | - Ana Regojo
- Department of Nursing, Breast Surgical Oncology, Clinica Universidad de Navarra, Universidad de Navarra, Marquesado de Santa Marta 1, Madrid, 28027, Spain
| | - Isabel T Rubio
- Department of Breast Surgical Oncology, Clinica Universidad de Navarra, Universidad de Navarra, Marquesado de Santa Marta 1, Madrid, 28027, Spain.
| |
Collapse
|
4
|
Ferrucci M, Milardi F, Passeri D, Mpungu LF, Francavilla A, Cagol M, Saibene T, Michieletto S, Toffanin M, Del Bianco P, Grossi U, Marchet A. Intraoperative Ultrasound-Guided Conserving Surgery for Breast Cancer: No More Time for Blind Surgery. Ann Surg Oncol 2023; 30:6201-6214. [PMID: 37606837 DOI: 10.1245/s10434-023-13900-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Accepted: 06/23/2023] [Indexed: 08/23/2023]
Abstract
BACKGROUND Breast-conserving surgery (BCS) still remains a blind surgery despite all available tumor localization methods. Intraoperative ultrasound (IOUS) allows real-time visualization during all resection phases. METHODS This was a prospective observational cohort study conducted at the Veneto Institute of Oncology between January 2021 and June 2022. Patients with ductal carcinoma in situ, T1-2 invasive cancer, or post-neoadjuvant tumors, suitable for BCS, were recruited. All breast cancer lesion types were included, i.e. solid palpable, solid non-palpable, non-solid non-palpable, and post-neoadjuvant treatment residual lesions. Eligible participants were randomly assigned to either IOUS or traditional surgery (TS) in a 1:1 ratio. The main outcomes were surgical margin involvement, reoperation rate, closest margin width, main specimen and cavity shaving margin volumes, excess healthy tissue removal, and calculated resection ratio (CRR). RESULTS Overall, 160 patients were enrolled: 80 patients were allocated to the TS group and 80 to the IOUS group. IOUS significantly reduced specimen volumes (16.8 cm3 [10.5-28.9] vs. 24.3 cm3 [15.0-41.3]; p = 0.015), with wider closest resection margin width (2.0 mm [1.0-4.0] vs. 1.0 mm [0.5-2.0] after TS; p < 0.001). Tumor volume to specimen volume ratio was significantly higher after IOUS (4.7% [2.5-9.1] vs. 2.9% [0.8-5.2]; p < 0.001). IOUS yielded significantly better CRR (84.5% [46-120.8] vs. 114% [81.8-193.2] after TS; p < 0.001), lower involved margin rate (2.5 vs. 15%; p = 0.009) and reduced re-excision rate (2.5 vs. 12.5%; p = 0.032). CONCLUSIONS IOUS allows real-time resection margin visualization and continuous control during BCS. It showed clear superiority over TS in both oncological and surgical outcomes for all breast cancer lesion types. These results disfavor the paradigm of blind breast surgery.
Collapse
Affiliation(s)
- Massimo Ferrucci
- Breast Surgery Unit, Veneto Institute of Oncology IOV, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Padua, Italy.
| | - Francesco Milardi
- General Surgery, Department of Surgery, Oncology and Gastroenterology, University of Padua, Padua, Italy
| | - Daniele Passeri
- General Surgery, Department of Surgery, Oncology and Gastroenterology, University of Padua, Padua, Italy
| | | | - Andrea Francavilla
- Unit of Biostatistics, Epidemiology and Public Health, Department of CardiacThoracic Vascular Sciences and Public Health, University of Padua, Padua, Italy
| | - Matteo Cagol
- Breast Surgery Unit, Veneto Institute of Oncology IOV, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Padua, Italy
| | - Tania Saibene
- Breast Surgery Unit, Veneto Institute of Oncology IOV, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Padua, Italy
| | - Silvia Michieletto
- Breast Surgery Unit, Veneto Institute of Oncology IOV, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Padua, Italy
| | - Mariacristina Toffanin
- Breast Surgery Unit, Veneto Institute of Oncology IOV, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Padua, Italy
| | - Paola Del Bianco
- Clinical Trials and Biostatistics, Veneto Institute of Oncology IOV, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Padua, Italy
| | - Ugo Grossi
- General Surgery, Department of Surgery, Oncology and Gastroenterology, University of Padua, Padua, Italy
| | - Alberto Marchet
- Breast Surgery Unit, Veneto Institute of Oncology IOV, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Padua, Italy
| |
Collapse
|
5
|
Ferrucci M, Milardi F, Marchet A. ASO Author Reflections: Is the Era of Blind Breast Surgery Coming to an End? IOUS (Intra-Operative Ultrasound-guided Surgery). Ann Surg Oncol 2023; 30:6217-6218. [PMID: 37530993 DOI: 10.1245/s10434-023-14007-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Accepted: 07/11/2023] [Indexed: 08/03/2023]
Affiliation(s)
- Massimo Ferrucci
- Breast Surgery Unit, Veneto Institute of Oncology IOV, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Padua, Italy.
| | - Francesco Milardi
- General Surgery, Department of Surgery, Oncology and Gastroenterology, University of Padua, Padua, Italy
| | - Alberto Marchet
- Breast Surgery Unit, Veneto Institute of Oncology IOV, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Padua, Italy
| |
Collapse
|
6
|
Jansen BAM, Bargon CA, Huibers AE, Postma EL, Young-Afat DA, Verkooijen HM, Doeksen A. Efficacy of indocyanine green fluorescence for the identification of non-palpable breast tumours: systematic review. BJS Open 2023; 7:zrad092. [PMID: 37751322 PMCID: PMC10521764 DOI: 10.1093/bjsopen/zrad092] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 06/22/2023] [Accepted: 07/20/2023] [Indexed: 09/28/2023] Open
Abstract
BACKGROUND Accurate tumour localization is crucial for precise surgical targeting and complete tumour removal. Indocyanine green fluorescence, an increasingly used technique in oncological surgery, has shown promise in localizing non-palpable breast tumours. The aim of this systematic review was to describe the efficacy of indocyanine green fluorescence for the identification of non-palpable breast tumours. METHODS A systematic literature search was performed in PubMed, Embase, and the Cochrane Library, including studies from 2012 to 2023. Studies reporting the proportion of breast tumours identified using indocyanine green fluorescence were included. The quality of the studies and their risk of bias were appraised using the Methodological Index for Non-Randomized Studies ('MINORS') tool. The following outcomes were collected: identification rate, clear resection margins, specimen volume, operative time, re-operation rate, adverse events, and complications. RESULTS In total, 2061 articles were screened for eligibility, resulting in 11 studies, with 366 patients included: two RCTs, three non-randomized comparative studies, four single-arm studies, and two case reports. All studies achieved a 100 per cent tumour identification rate with indocyanine green fluorescence, except for one study, with an identification rate of 87 per cent (13/15). Clear resection margins were found in 88-100 per cent of all patients. Reoperation rates ranged from 0.0 to 5.4 per cent and no complications or adverse events related to indocyanine green occurred. CONCLUSION Indocyanine green fluorescence has substantial theoretical advantages compared with current routine localization methods. Although a limited number of studies were available, the current literature suggests that indocyanine green fluorescence is a useful, accurate, and safe technique for the intraoperative localization of non-palpable breast tumours, with equivalent efficacy compared with other localization techniques, potentially reducing tumour-positive margins.
Collapse
Affiliation(s)
- Britt A M Jansen
- Division of Imaging and Oncology, University Medical Centre (UMC), Utrecht University, Utrecht, The Netherlands
- Department of Surgery, St Antonius Hospital, Utrecht, The Netherlands
- Department of Plastic, Reconstructive and Hand Surgery, St Antonius Hospital, Utrecht, The Netherlands
| | - Claudia A Bargon
- Division of Imaging and Oncology, University Medical Centre (UMC), Utrecht University, Utrecht, The Netherlands
- Department of Surgery, St Antonius Hospital, Utrecht, The Netherlands
- Department of Plastic, Reconstructive and Hand Surgery, St Antonius Hospital, Utrecht, The Netherlands
| | - Anne E Huibers
- Department of Surgery, St Antonius Hospital, Utrecht, The Netherlands
| | - Emily L Postma
- Department of Surgery, St Antonius Hospital, Utrecht, The Netherlands
| | - Danny A Young-Afat
- Department of Plastic, Reconstructive and Hand Surgery, Amsterdam University Medical Centre, Amsterdam, The Netherlands
| | - Helena M Verkooijen
- Division of Imaging and Oncology, University Medical Centre (UMC), Utrecht University, Utrecht, The Netherlands
- Utrecht University (UU), Utrecht, The Netherlands
| | - Annemiek Doeksen
- Department of Surgery, St Antonius Hospital, Utrecht, The Netherlands
| |
Collapse
|
7
|
Fosko NK, Gribkova Y, Krupa K, Bs KJ, Moore D, Chen C, Potdevin L, Kumar S, Eladoumikdachi F, Kowzun MJ. The Use of Intraoperative Ultrasound During Breast Conserving Surgery. Clin Breast Cancer 2023; 23:54-59. [PMID: 36319507 DOI: 10.1016/j.clbc.2022.10.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Accepted: 10/07/2022] [Indexed: 12/27/2022]
Abstract
OBJECTIVES The purpose of this study is to evaluate the utilization of intraoperative ultrasound (IOUS) for tumor localization in breast-conserving surgery and to examine its impact on margin positivity and re-excision rates. Additionally, the study seeks to identify factors contributing to surgeon utilization of IOUS. METHODS A retrospective chart review was conducted of patients with preoperative diagnosis of breast cancer undergoing breast-conserving surgery by breast surgeons at multiple centers within a single healthcare system. Characteristics such as lesion size, palpability, histology, receptor status, and use of neoadjuvant chemotherapy were recorded. Re-excision rates were determined based on localization technique and surgeons' status of breast ultrasound certification. RESULTS A total of 671 cases were performed, with 322 meeting study inclusion. 57 cases utilized IOUS, 250 utilized preoperative wire-guided localization (WGL), 10 used both methods and 5 cases used neither method. There was no significant difference in re-excision rates between IOUS and WGL or among the four surgeons. Ultrasound-certified surgeons were more likely to utilize IOUS, and re-excision rates trended higher for WGL, which may be clinically significant. CONCLUSION Increasing familiarity with and utilization of IOUS during breast-conserving surgery may be clinically advantageous over traditional localization techniques. Ultrasound certification may lead to increased use of IOUS among surgeons.
Collapse
Affiliation(s)
- Nicole K Fosko
- Rutgers-Robert Wood Johnson Medical School, New Brunswick, New Jersey
| | | | - Kelly Krupa
- Rutgers Cancer Institute of New Jersey, New Brunswick, New Jersey
| | - Kavita Jain Bs
- Rutgers-Robert Wood Johnson Medical School, New Brunswick, New Jersey
| | - Dirk Moore
- Rutgers School of Public Health, New Brunswick, New Jersey
| | - Chunxia Chen
- Rutgers-Robert Wood Johnson Medical School, New Brunswick, New Jersey
| | - Lindsay Potdevin
- Rutgers Cancer Institute of New Jersey, New Brunswick, New Jersey
| | - Shicha Kumar
- Rutgers Cancer Institute of New Jersey, New Brunswick, New Jersey
| | | | - Maria J Kowzun
- Rutgers Cancer Institute of New Jersey, New Brunswick, New Jersey.
| |
Collapse
|
8
|
Aristokleous I, Öberg J, Pantiora E, Sjökvist O, Navia JE, Mani M, Karakatsanis A. Effect of standardised surgical assessment and shared decision-making on morbidity and patient satisfaction after breast conserving therapy: A cross-sectional study. EUROPEAN JOURNAL OF SURGICAL ONCOLOGY 2023; 49:60-67. [PMID: 36088236 DOI: 10.1016/j.ejso.2022.08.021] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Revised: 07/11/2022] [Accepted: 08/19/2022] [Indexed: 01/24/2023]
Abstract
BACKGROUND The role of oncoplastic breast conserving therapy (OPBCT) on physical function, morbidity and patient satisfaction has yet to be defined. Additionally, technique selection should be individualised and incorporate patient preference. The study aim was to investigate differences between "standard" (sBCT) and oncoplastic breast conservation (OPBCT) in patient-reported outcomes (PROs) when patients have been assessed in a standardised manner and technique selection has been reached through shared decision-making (SDM). METHODS This is a cross-sectional study of 215 women treated at a tertiary referral centre. Standardised surgical assessment included breast and lesion volumetry, definition of resection ratio, patient-related risk factors and patient preference. Postoperative morbidity and patient satisfaction were assessed by validated PROs tools (Diseases of the Arm, Shoulder and Hand-DASH and Breast-Q). Patient experience was assessed by semi-structured interviews. RESULTS There was no difference of the median values between OPBCT and sBCT in postoperative morbidity of the upper extremity (DASH 3.3 vs 5, p = 0.656) or the function of the chest wall (Breast-Q 82 vs 82, p = 0.758). Postoperative satisfaction with breasts did not differ either (Breast-Q 65 vs 61, p = 0.702). On the individual level, women that opted for OPBCT after SDM had improved satisfaction when compared to baseline (+3 vs -1, p = 0.001). Shared decision-making changed patient attitude in 69.8% of patients, leading most often to de-escalation from mastectomy. CONCLUSIONS These findings support that a combination of standardised surgical assessment and SDM allows for tailored treatment and de-escalation of oncoplastic surgery without negatively affecting patient satisfaction and morbidity.
Collapse
Affiliation(s)
- Iliana Aristokleous
- Department of Surgery, Endocrine- and Breast Unit, Uppsala University Hospital, 75237, Uppsala, Sweden; Department of Surgical Sciences, Faculty of Medicine, Uppsala University, 75236, Uppsala, Sweden
| | - Johanna Öberg
- Department of Surgery, Endocrine- and Breast Unit, Uppsala University Hospital, 75237, Uppsala, Sweden; Department of Surgical Sciences, Faculty of Medicine, Uppsala University, 75236, Uppsala, Sweden
| | - Eirini Pantiora
- Department of Surgery, Endocrine- and Breast Unit, Uppsala University Hospital, 75237, Uppsala, Sweden; Department of Surgical Sciences, Faculty of Medicine, Uppsala University, 75236, Uppsala, Sweden
| | - Olivia Sjökvist
- Department of Surgical Sciences, Faculty of Medicine, Uppsala University, 75236, Uppsala, Sweden; Department of Plastic and Maxillofacial Surgery, Uppsala University Hospital, 75237, Uppsala, Sweden
| | - Jaime E Navia
- Department of Surgery, Endocrine- and Breast Unit, Uppsala University Hospital, 75237, Uppsala, Sweden; Department of Surgical Sciences, Faculty of Medicine, Uppsala University, 75236, Uppsala, Sweden
| | - Maria Mani
- Department of Surgical Sciences, Faculty of Medicine, Uppsala University, 75236, Uppsala, Sweden; Department of Plastic and Maxillofacial Surgery, Uppsala University Hospital, 75237, Uppsala, Sweden
| | - Andreas Karakatsanis
- Department of Surgery, Endocrine- and Breast Unit, Uppsala University Hospital, 75237, Uppsala, Sweden; Department of Surgical Sciences, Faculty of Medicine, Uppsala University, 75236, Uppsala, Sweden.
| |
Collapse
|
9
|
Kataria K, Singh A, Jayaram J, Ranjan P, Srivastava A, Hari S, Mathur SR. Comparison of Wire-Guided Lumpectomy (WGL) Versus Hematoma-Directed Ultrasound-Guided Lumpectomy (HDUGL) in Management of Nonpalpable Breast Lesions in Achieving a Negative Resection Margin: a Randomized Trial with Superiority Hypothesis and Cost-effectiveness Analysis. Indian J Surg Oncol 2022; 13:834-841. [PMID: 36687222 PMCID: PMC9845449 DOI: 10.1007/s13193-022-01582-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2021] [Accepted: 06/25/2022] [Indexed: 01/25/2023] Open
Abstract
The advances in imaging techniques and growing awareness have increased the detection of nonpalpable breast lesions, which may be neoplastic or high-risk lesions. The standard technique of localizing these nonpalpable breast lesions is wire-guided biopsy/lumpectomy. However, wire-guided excision is fraught with the complications of migration, transection, patient discomfort, pneumothorax, vasovagal episodes, and injury to the radiologist, surgeon, and pathologist. We embarked upon a randomized controlled trial to compare the cost-effectiveness and patient-reported outcome (PRO) with hematoma-directed ultrasound-guided lumpectomy (HDUGL) versus conventional wire-guided lumpectomy (WGL) for nonpalpable breast lesions. This study was a parallel design, randomized controlled trial with a superiority hypothesis. Twenty-five patients could be randomized to wire-guided lumpectomy (WGL) group (n = 13) and hematoma-directed ultrasound-guided lumpectomy (HDUGL) group (n = 12). Post-excision specimen sonography and mammography for assessing adequacy of margin were done. A margin shave was performed in cases of close or suspicious margin on ultrasonography or mammogram. Both the groups were comparable in age, tumor size, histological subtypes, and location of lesions. The median resection volume in two groups was 34.5 (26.5) ml for HDUGL vs. 41 (15) ml for WGL. Intraoperative cavity shave was required only in the WGL group (n = 3.23%) and margin positivity was also more in the WGL group (n = 2,15.38%) as compared to the HDUGL group (n = 1,8.33%) but neither differences in cavity shave nor positive margins leading to re-operations were statistically significant. The difference in cost of surgery in two groups (INR 4680 ± 560.00 for HDUGL and INR 7486 ± 616.41 for WGL) was statistically significant (P = 0.00). Resultantly, HDUGL was more cost-effective (INR 5105.45) than WGL (INR 8847.09). Patients in the HDUGL group were more satisfied according to the Likert scale of 5 but this difference in two groups was not statistically significant (P = 0.07). The hematoma-directed ultrasound-guided lumpectomy (HDUGL) is better than wire-guided lumpectomy (WGL) for nonpalpable breast lesions in terms of cost-effectiveness. Trial details: CTRI No. CTRI/2019/05/019347. Registered on 24/05/2019, Registered prospectively.
Collapse
Affiliation(s)
- Kamal Kataria
- Department of Surgical Disciplines, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, 110029 India
| | - Ankita Singh
- Department of Surgical Disciplines, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, 110029 India
| | - Jnaneshwari Jayaram
- Department of Surgical Disciplines, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, 110029 India
| | - Piyush Ranjan
- Department of Surgical Disciplines, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, 110029 India
| | - Anurag Srivastava
- Department of Surgical Disciplines, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, 110029 India
| | - Smriti Hari
- Department of Radiodiagnosis, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, India
| | - Sandeep R. Mathur
- Department of Pathology, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, India
| |
Collapse
|
10
|
Banys-Paluchowski M, Rubio IT, Karadeniz Cakmak G, Esgueva A, Krawczyk N, Paluchowski P, Gruber I, Marx M, Brucker SY, Bündgen N, Kühn T, Rody A, Hanker L, Hahn M. Intraoperative Ultrasound-Guided Excision of Non-Palpable and Palpable Breast Cancer: Systematic Review and Meta-Analysis. ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2022; 43:367-379. [PMID: 35760079 DOI: 10.1055/a-1821-8559] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Wire-guided localization (WGL) is the most frequently used localization technique in non-palpable breast cancer (BC). However, low negative margin rates, patient discomfort, and the possibility of wire dislocation have been discussed as potential disadvantages, and re-operation due to positive margins may increase relapse risk. Intraoperative ultrasound (IOUS)-guided excision allows direct visualization of the lesion and the resection volume and reduces positive margins in palpable and non-palpable tumors. We performed a systematic review on IOUS in breast cancer and 2 meta-analyses of randomized clinical trials (RCTs). In non-palpable BC, 3 RCTs have shown higher negative margin rates in the IOUS arm compared to WGL. Meta-analysis confirmed a significant difference between IOUS and WGL in terms of positive margins favoring IOUS (risk ratio 4.34, p < 0.0001, I2 = 0%). 41 cohort studies including 3291 patients were identified, of which most reported higher negative margin and lower re-operation rates if IOUS was used. In palpable BC, IOUS was compared to palpation-guided excision in 3 RCTs. Meta-analysis showed significantly higher rates of positive margins in the palpation arm (risk ratio 2.84, p = 0.0047, I2 = 0%). In 13 cohort studies including 942 patients with palpable BC, negative margin rates were higher if IOUS was used, and tissue volumes were higher in palpation-guided cohorts in most studies. IOUS is a safe noninvasive technique for the localization of sonographically visible tumors that significantly improves margin rates in palpable and non-palpable BC. Surgeons should be encouraged to acquire ultrasound skills and participate in breast ultrasound training.
Collapse
Affiliation(s)
- Maggie Banys-Paluchowski
- Department of Gynecology and Obstetrics, University Hospital Schleswig-Holstein Campus Lübeck, Lübeck, Germany
- Medical Faculty, Heinrich Heine University Düsseldorf, Dusseldorf, Germany
| | - Isabel T Rubio
- Breast Surgical Unit, Clinica Universidad de Navarra, Madrid, Spain
| | - Güldeniz Karadeniz Cakmak
- General Surgery Department, Breast and Endocrine Unit, Zonguldak BEUN The School of Medicine, Kozlu/Zonguldak, Turkey
| | - Antonio Esgueva
- Breast Surgical Unit, Clinica Universidad de Navarra, Madrid, Spain
| | - Natalia Krawczyk
- Department of Obstetrics and Gynecology, Heinrich Heine University Düsseldorf, Dusseldorf, Germany
| | - Peter Paluchowski
- Department of Gynecology and Obstetrics, Regio Klinikum Pinneberg, Pinneberg, Germany
| | - Ines Gruber
- Department for Women's Health, University of Tübingen, Tübingen, Germany
| | - Mario Marx
- Department of Plastic, Reconstructive and Breast Surgery, Elblandklinikum Radebeul, Radebeul, Germany
| | - Sara Y Brucker
- Department for Women's Health, University of Tübingen, Tübingen, Germany
| | - Nana Bündgen
- Department of Gynecology and Obstetrics, University Hospital Schleswig-Holstein Campus Lübeck, Lübeck, Germany
| | - Thorsten Kühn
- Department of Gynecology and Obstetrics, Klinikum Esslingen, Esslingen, Germany
| | - Achim Rody
- Department of Gynecology and Obstetrics, University Hospital Schleswig-Holstein Campus Lübeck, Lübeck, Germany
| | - Lars Hanker
- Department of Gynecology and Obstetrics, University Hospital Schleswig-Holstein Campus Lübeck, Lübeck, Germany
| | - Markus Hahn
- Department for Women's Health, University of Tübingen, Tübingen, Germany
| |
Collapse
|
11
|
Guo W, Ji W, Zhang T, Xing Z, Xing F. Indocyanine Green Fluorescence–Guided Lumpectomy of Nonpalpable Breast Cancer Versus Ultrasound-Guided Excision. Surg Innov 2022; 29:573-578. [PMID: 35225072 DOI: 10.1177/15533506211039962] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Purpose The purpose of this study was to evaluate the use of indocyanine green–guided nonpalpable breast cancer lesion localization (INBCL) and to compare it with ultrasound localization (US). Methods We retrospectively reviewed 78 consecutive patients undergoing breast-conserving surgery for nonpalpable breast cancer (NBC). Of all 78 excisions, 42 cases were guided by INBCL and 36 by US. Results The rate of clear margins was 90.5% (38/42) in the INBCL group compared to the 83.3% (30/36) in the US ( P = .548). A comparison of the margins at first excision for both INBCL and US, in the INBCL series, 92.9% (39/42) of cases had a margin less than 5 mm, whereas for US series, it was 72.2% (26/36) ( P = .033). When results of the excised tissue are taken into account, the mean specimen volume for INBCL was 58 cm3, but for US it was 73 cm3, with difference in mean volume being 15 cm3 ( P = .062). Conclusions INBCL for NBCs was more accurate than US because a smaller volume of the tissue may be excised by using the technique, without compromising margin status in nonpalpable lesions.
Collapse
Affiliation(s)
- Wenbin Guo
- The Breast Center, Department of Surgery, Dalian Central Hospital, Dalian Medical University, Dalian, China
| | - Wencai Ji
- The Breast Center, Department of Surgery, Dalian Central Hospital, Dalian Medical University, Dalian, China
| | - Tianyi Zhang
- The Breast Center, Department of Surgery, Dalian Central Hospital, Dalian Medical University, Dalian, China
| | - Zhihang Xing
- The Breast Center, Department of Surgery, Dalian Central Hospital, Dalian Medical University, Dalian, China
| | - Fei Xing
- The Breast Center, Department of Surgery, Dalian Central Hospital, Dalian Medical University, Dalian, China
| |
Collapse
|
12
|
Citgez B, Yigit B, Bas S. Oncoplastic and Reconstructive Breast Surgery: A Comprehensive Review. Cureus 2022; 14:e21763. [PMID: 35251834 PMCID: PMC8890601 DOI: 10.7759/cureus.21763] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/31/2022] [Indexed: 12/13/2022] Open
|
13
|
Redfern RE, Shermis RB. Initial Experience Using Magseed for Breast Lesion Localization Compared With Wire-Guided Localization: Analysis of Volume and Margin Clearance Rates. Ann Surg Oncol 2022; 29:3776-3783. [DOI: 10.1245/s10434-022-11327-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Accepted: 12/27/2021] [Indexed: 11/18/2022]
|
14
|
Zhou Y, Liang Y, Zhang J, Feng Y, Li X, Kong X, Ma T, Jiang L, Yang Q. Evaluation of Carbon Nanoparticle Suspension and Methylene Blue Localization for Preoperative Localization of Nonpalpable Breast Lesions: A Comparative Study. Front Surg 2021; 8:757694. [PMID: 34888344 PMCID: PMC8651243 DOI: 10.3389/fsurg.2021.757694] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2021] [Accepted: 10/18/2021] [Indexed: 11/24/2022] Open
Abstract
Background: The resection of nonpalpable breast lesions (NPBLs) largely depends on the preoperative localization technology. Although several techniques have been used for the guidance of NPBL resection, more comfortable and effective methods are needed. This aim of this study was to evaluate the use and feasibility of carbon nanoparticle suspension (CNS) and methylene blue (MB)-guided resection of NPBL, to introduce alternative techniques. Methods: A total of 105 patients with 172 NPBLs detected by breast ultrasound were randomized to CNS localization (CNSL) group and MB localization (MBL) group. The injection times of the two groups were divided into 2, 4, 6, 12, 16, and 20 h before surgery. In this study, localization time, stained area, operation time, total resection volume (TRV), calculated resection ratio (CRR), and pathological diagnosis were assessed. Results: All of the 172 lesions were finally confirmed benign. Dye persisted in all cases in the CNSL group (109/109, 100%), while that persisted in only 53 cases in the MBL group (53/63, 84.1%) (P < 0.001). There was a significant correlation between dyeing time and dyeing area in the MBL group (r = −0.767, P < 0.001); however, there was no significant correlation in the CNSL group (r = −0.154, P = 0.110). The operation time was 11.05 ± 3.40 min in the CNSL group and 13.48 ± 6.22 min in the MBL group (P < 0.001). The TRV was 2.51 ± 2.42 cm3 in the CNSL group and 3.69 ± 3.24 cm3 in the MBL group (P = 0.016). For CRR, the CNSL group was lower than the MBL group (7.62 ± 0.49 vs. 21.93 ± 78.00, P = 0.018). There is no dye remained on the skin in the MBL group; however, dye persisted in 12 patients (19.4%) in the CNSL group (P = 0.001). Conclusion: Carbon nanoparticle suspension localization and MBL are technically applicable and clinically acceptable procedures for intraoperatively localizing NPBL. Moreover, given the advantages of CNSL compared to MBL, including the ability to perform this technique 5 days before operation and smaller resection volume, it seems to be a more attractive alternative to be used in intraoperative localization of NPBL.
Collapse
Affiliation(s)
- Yeqing Zhou
- Department of Breast Surgery, General Surgery, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, China.,Department of Breast Surgery, The Affiliated Yantai Yuhuangding Hospital of Qingdao University, Yantai, China
| | - Yiran Liang
- Department of Breast Surgery, General Surgery, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, China
| | - Jianshu Zhang
- Department of Breast Surgery, General Surgery, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, China
| | - Yang Feng
- Department of Breast Surgery, General Surgery, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, China
| | - Xiaoyan Li
- Department of Breast Surgery, General Surgery, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, China
| | - Xiaoli Kong
- Department of Breast Surgery, General Surgery, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, China
| | - Tingting Ma
- Department of Breast Surgery, General Surgery, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, China
| | - Liyu Jiang
- Department of Breast Surgery, General Surgery, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, China
| | - Qifeng Yang
- Department of Breast Surgery, General Surgery, Qilu Hospital, Cheeloo College of Medicine, Shandong University, Jinan, China.,Pathology Tissue Bank, Qilu Hospital of Shandong University, Jinan, China.,Research Institute of Breast Cancer, Shandong University, Jinan, China
| |
Collapse
|
15
|
Bennett I, Khoo JF, De Viana D, Law M. Australian breast surgeons and ultrasound usage: Have practices changed? Australas J Ultrasound Med 2021; 24:217-224. [PMID: 34888131 PMCID: PMC8591276 DOI: 10.1002/ajum.12277] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2020] [Revised: 05/17/2021] [Accepted: 05/30/2021] [Indexed: 11/05/2022] Open
Abstract
BACKGROUND A recent survey of surgeon performed ultrasound usage was conducted amongst registered members of the Breast Surgeons of Australia and New Zealand Society (BreastSurgANZ) and was compared with a previous survey undertaken in 2010 to determine whether patterns of utilization had changed. METHODS From July to September 2019, members of BreastSurgANZ were invited to complete an electronic online survey of personal usage of breast ultrasound focusing on ultrasound equipment access, use of office and intraoperative ultrasound, biopsy interventions and training expectations. RESULTS There were 73 respondents to the survey with 45 (61.6%) members indicating access to ultrasound within their practices. Whilst current regular ultrasound usage (68.1%) was only slightly greater than in 2010 (66%), the proportion of respondents not performing any form of needle intervention had increased (62.5% compared to 53% in 2010) and with the proportion of surgeons currently performing >10 biopsies per month decreasing from 10% to only 5.56%. However the percentage of surgeons utilizing intraoperative ultrasound had notably increased since 2010 with 49.3% currently using ultrasound in the operating room compared with only 17% previously. The majority of respondents believed that breast ultrasound training should be conducted through BreastSurgANZ post fellowship training programs. CONCLUSION The overall utilization of surgeon-performed ultrasound amongst BreastSurgANZ members has remained similar over the past 9 years with the performance of needle interventions declining slightly, but with the application of intraoperative ultrasound having increased. An ultrasound training curriculum as part of the BreastSurgANZ post fellowship training program is a necessary imperative.
Collapse
Affiliation(s)
- Ian Bennett
- Department of SurgeryPrincess Alexandra HospitalUniversity of QldWoolloongabba, BrisbaneQueenslandAustralia
- Translational Research Institute (TRI)Princess Alexandra HospitalWoolloongabba, BrisbaneQueenslandAustralia
| | - Jeremy F. Khoo
- Department of SurgeryPrincess Alexandra HospitalUniversity of QldWoolloongabba, BrisbaneQueenslandAustralia
- Translational Research Institute (TRI)Princess Alexandra HospitalWoolloongabba, BrisbaneQueenslandAustralia
| | - Daniel De Viana
- BreastScreen Qld Gold CoastPremion PlaceSouthportQueenslandAustralia
| | - Michael Law
- Breast and Endocrine Surgery UnitEastern HealthBox HillVictoriaAustralia
| |
Collapse
|
16
|
Dickhoff LR, Vrancken Peeters MJ, Bosman PA, Alderliesten T. Therapeutic applications of radioactive sources: from image-guided brachytherapy to radio-guided surgical resection. THE QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING : OFFICIAL PUBLICATION OF THE ITALIAN ASSOCIATION OF NUCLEAR MEDICINE (AIMN) [AND] THE INTERNATIONAL ASSOCIATION OF RADIOPHARMACOLOGY (IAR), [AND] SECTION OF THE SOCIETY OF... 2021; 65:190-201. [PMID: 34105339 DOI: 10.23736/s1824-4785.21.03370-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
It is well known nowadays that radioactivity can destroy the living cells it interacts with. It is therefore unsurprising that radioactive sources, such as iodine-125, were historically developed for treatment purposes within radiation oncology with the goal of damaging malignant cells. However, since then, new techniques have been invented that make creative use of the same radioactivity properties of these sources for medical applications. Here, we review two distinct kinds of therapeutic uses of radioactive sources with applications to prostate, cervical, and breast cancer: brachytherapy and radioactive seed localization. In brachytherapy (BT), the radioactive sources are used for internal radiation treatment. Current approaches make use of real-time image guidance, for instance by means of magnetic resonance imaging, ultrasound, computed tomography, and sometimes positron emission tomography, depending on clinical availability and cancer type. Such image-guided BT for prostate and cervical cancer presents a promising alternative and/or addition to external beam radiation treatments or surgical resections. Radioactive sources can also be used for radio-guided tumor localization during surgery, for which the example of iodine-125 seed use in breast cancer is given. Radioactive seed localization (RSL) is increasingly popular as an alternative tumor localization technique during breast cancer surgery. Advantages of applying RSL include added flexibility in the clinical scheduling logistics, an increase in tumor localization accuracy, and higher patient satisfaction; safety measures do however have to be employed. We exemplify the implementation of RSL in a clinic through experiences at the Netherlands Cancer Institute.
Collapse
Affiliation(s)
- Leah R Dickhoff
- Department of Radiation Oncology, Leiden University Medical Center, Leiden, The Netherlands -
| | - Marie-Jeanne Vrancken Peeters
- Department of Surgical Oncology, Netherlands Cancer Institute - Antoni van Leeuwenhoek, Amsterdam, The Netherlands.,Department of Surgery, Amsterdam University Medical Centers, Amsterdam, The Netherlands
| | - Peter A Bosman
- Life Sciences and Health group, Centrum Wiskunde & Informatica, Amsterdam, The Netherlands
| | - Tanja Alderliesten
- Department of Radiation Oncology, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
17
|
Lee EG, Kim SK, Han JH, Lee DE, Jung SY, Lee S. Surgical outcomes of localization using indocyanine green fluorescence in breast conserving surgery: a prospective study. Sci Rep 2021; 11:9997. [PMID: 33976314 PMCID: PMC8113252 DOI: 10.1038/s41598-021-89423-w] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Accepted: 04/23/2021] [Indexed: 11/18/2022] Open
Abstract
We investigated localization and safe resection margins for breast cancer patients undergoing breast conserving surgery (BCS) using ultrasound-guided indocyanine green fluorescence (ICG-F) marking. From April 2016 to March 2019, we prospectively enrolled 114 patients who underwent BCS using US-guided ICG-F marking and we compared these results with 300 patients who underwent BCS using US-guided skin marking from January 2012 to December 2016. Clinical features, identification rates, status of resection margins, and re-operation rates were analyzed. The ICG-F identification rate was 100% (114/114). The mean approach time for resection of the lesion ICG-F using group was about 13 min. The positive rate of frozen resection margins was 10.5% using ICG-F and 25.0% using sono-guided skin marking (p < 0.01). The rate of additional intraoperative resection was significantly lower in the ICG-F marking group compared to that in the sono-guided skin marking group (8.8% vs. 23.3%, p < 0.01). The rate of final positive resection margins was 3.5% in the ICG-F using group and 14.7% in the sono-guided skin marking group (p < 0.01). The rate of re-operation was 4.4% in the ICG-F using group and 4% in the sono-guided group (p = 0.79). At follow-up after the operation using ICG-F, no complications occurred. Using ICG-F during BCS could be a safe, sophisticated method for localization.
Collapse
Affiliation(s)
- Eun-Gyeong Lee
- Department of Surgery, Center for Breast Cancer, Research Institute and Hospital, National Cancer Center, 323 Ilsan ro, Ilsandong-gu, Goyang-si, Gyeonggi-do, 10408, South Korea
| | - Seok-Ki Kim
- Department of Nuclear Medicine, National Cancer Center, Goyang, South Korea
| | - Jai Hong Han
- Department of Surgery, Center for Breast Cancer, Research Institute and Hospital, National Cancer Center, 323 Ilsan ro, Ilsandong-gu, Goyang-si, Gyeonggi-do, 10408, South Korea
| | - Dong-Eun Lee
- Biostatistics Collaboration Team, Research Core Center, Research Institute of National Cancer Center, Goyang, South Korea
| | - So-Youn Jung
- Department of Surgery, Center for Breast Cancer, Research Institute and Hospital, National Cancer Center, 323 Ilsan ro, Ilsandong-gu, Goyang-si, Gyeonggi-do, 10408, South Korea.
| | - Seeyoun Lee
- Department of Surgery, Center for Breast Cancer, Research Institute and Hospital, National Cancer Center, 323 Ilsan ro, Ilsandong-gu, Goyang-si, Gyeonggi-do, 10408, South Korea.
| |
Collapse
|
18
|
Kim I, Choi HJ, Ryu JM, Lee SK, Yu JH, Lee JE, Nam SJ, Shin HJ, Kim SW. The efficacy and safety of indocyanine green-hyaluronic acid mixture (LuminoMark™) for localization in patients with non-palpable breast lesions: a multi-center open-label parallel phase-2 clinical trial. BMC Surg 2021; 21:134. [PMID: 33726718 PMCID: PMC7968200 DOI: 10.1186/s12893-021-01129-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Accepted: 02/28/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Increasing rates of breast cancer screening have been associated with an increasing frequency of non-palpable breast lesions detection. Preoperative breast lesion localization is essential for optimizing excision accuracy. This study aimed to evaluate the efficacy and safety of indocyanine green (ICG) hyaluronic acid injection as a novel mixture for localization. METHODS We performed a prospective clinical trial with female patients who underwent surgery for non-palpable breast lesions. All patients were sequentially assigned to the control group (localization with activated charcoal), Test Group 1 (ICG-hyaluronic acid mixture 0.1 mL), or Test Group 2 (ICG-hyaluronic acid mixture 0.2 mL) by 1:1:1 ratio. RESULTS A total of 44 patients were eligible for this study (Control Group = 14, Test Group 1 = 15, Test Group 2 = 15 patients). Fibroadenoma (n = 17, 38.6%) accounted for the largest proportion of diagnoses, and five patients (11.4%) were diagnosed with malignancies. There were no statistically significant differences in baseline characteristics among the three groups. The marking rate was over 86% in all groups, with no significant intergroup differences. Skin pigmentation was only observed in the control group. The mean accuracy of resection (the greatest diameter of the excised specimen divided by the greatest diameter of the preoperative lesion as observed using ultrasonography, with values closer to 1 reflecting a higher accuracy) was 3.7 in the control group, 2.2 in Test Group 1, and 2.1 in Test Group 2 (p = 0.037 between Controls and Test Group 1, p = 0.744 between Test Group 1 and Test Group 2, and p = 0.026 between Controls and Test Group 2). CONCLUSION ICG-hyaluronic acid injection is a novel method that was shown to accurately localize non-palpable breast lesions and was associated with no skin pigmentation. Further research is required to apply this method to malignant breast lesions. Trial registration "A Multicenter Open-label, Parallel, Phase 2 Clinical Trial to Evaluate the Efficacy and Safety of LuminoMark™ Inj. (Conc. for Fluorescence) Localization in Patients with Non-palpable Breast Lesions" was prospectively registered as a trial (ClinicalTrials. gov Identifier: NCT03743259, date of registration: May 29, 2018, https://clinicaltrials.gov/ct2/show/NCT03743259 ).
Collapse
Affiliation(s)
- Isaac Kim
- Department of Surgery, Bundang CHA Medical Center, CHA University School of Medicine, 59 Yatap-ro, Bundang-gu, Seongnam-si, Gyeonggi, Republic of Korea
| | - Hee Jun Choi
- Division of Breast Surgery, Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 06351, Republic of Korea
| | - Jai Min Ryu
- Division of Breast Surgery, Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 06351, Republic of Korea
| | - Se Kyung Lee
- Division of Breast Surgery, Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 06351, Republic of Korea
| | - Jong Han Yu
- Division of Breast Surgery, Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 06351, Republic of Korea
| | - Jeong Eon Lee
- Division of Breast Surgery, Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 06351, Republic of Korea
| | - Seok Jin Nam
- Division of Breast Surgery, Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 06351, Republic of Korea
| | - Hyuk Jai Shin
- Department of Surgery, Myongji Hospital, Hanyang University College of Medicine, Gyeonggi, Republic of Korea
| | - Seok Won Kim
- Division of Breast Surgery, Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 06351, Republic of Korea.
| |
Collapse
|
19
|
Hu X, Li S, Jiang Y, Wei W, Ji Y, Li Q, Jiang Z. Intraoperative ultrasound-guided lumpectomy versus wire-guided excision for nonpalpable breast cancer. J Int Med Res 2020; 48:300060519896707. [PMID: 31937169 PMCID: PMC7113704 DOI: 10.1177/0300060519896707] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
Objective This study was designed to compare the margin clearance and re-excision rates of ultrasound (US)- and wire-guided excision in a large number of patients with nonpalpable breast cancer. Methods In total, 520 women who were histologically diagnosed with nonpalpable breast cancer were recruited in this study. All nonpalpable lesions were visible by US. The patients were randomly divided into two groups: those who underwent wire-guided breast-conserving surgery (BCS) and those who underwent US-guided BCS. Re-excision rates and positive surgical margins were recorded. Results A total of 262 patients underwent US-guided excision and 258 patients underwent wire-guided excision. No differences were found in tumor or patient characteristics. The positive margin rate was 4.6% in the US-guided group and 19.4% in the wire-guided group with a significant difference. Age, menopausal status, excision volume, histological grade, and tumor type significantly influenced the positive surgical margin rate. The intraoperative re-excision rate was significantly lower in the US-guided group than wire-guided group (11.1% vs. 24.0%, respectively). Conclusions US-guided BCS seems to be more effective than wire-guided BCS for treatment of nonpalpable breast cancers in terms of the margin clearance and re-excision rates. Patients can avoid the discomfort caused by preoperative wire placement.
Collapse
Affiliation(s)
- Xin Hu
- Department of Pain Management, The Second Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi, China
| | - Si Li
- Department of Breast Surgery, Affiliated Tumor Hospital of Guangxi Medical University, Nanning, Guangxi, China
| | - Yi Jiang
- Department of Breast Surgery, Affiliated Tumor Hospital of Guangxi Medical University, Nanning, Guangxi, China
| | - Wei Wei
- Department of Breast Surgery, Affiliated Tumor Hospital of Guangxi Medical University, Nanning, Guangxi, China
| | - Yinan Ji
- Department of Breast Surgery, Affiliated Tumor Hospital of Guangxi Medical University, Nanning, Guangxi, China
| | - Qiuyun Li
- Department of Breast Surgery, Affiliated Tumor Hospital of Guangxi Medical University, Nanning, Guangxi, China
| | - Zongbin Jiang
- Department of Pain Management, The Second Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi, China
| |
Collapse
|
20
|
Ozmen T, Avisar E. The Impact of Advanced Image-Guided Breast Surgery and Oncoplastic Techniques on Margin Positivity in Breast Conserving Surgery. Cureus 2020; 12:e11831. [PMID: 33409073 PMCID: PMC7781498 DOI: 10.7759/cureus.11831] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
Objective Positive margins remain a significant psychological and economic burden after breast conserving surgery. The aim of this study was to test the hypothesis that advanced oncoplastic techniques as well as intraoperative integrative imaging with intraoperative ultrasound and mobile digital specimen radiography decreases positive margin rate in breast conserving surgery. Methods A single-institution retrospective review of a prospectively collected database was performed. Patients with breast neoplasms who underwent lumpectomy with or without using intraoperative integrative imaging approaches and oncoplastic techniques were included. The primary outcome was positive margin rate for each technique. Results A total of 392 patients were included in the study. The median age of the cohort was 59 years. Overall positive margin rate was 15%. Ductal carcinoma in situ (DCIS) histology and larger tumor size were associated with higher positive margin rate. Intraoperative integrative imaging significantly decreased positive margin rate (9% vs. 18%, p=0.018). Oncoplastic techniques also decreased positive margin rate from 16% to 12%, however this was not significant. Conclusion Positive margin rate was significantly lower when intraoperative integrative imaging was used. Oncoplastic techniques also decreased positive margin rate in a selected group of patients with large tumor size. We suggest incorporating these techniques in all breast conserving surgery cases.
Collapse
Affiliation(s)
- Tolga Ozmen
- Surgical Oncology, University of Miami, Miller School of Medicine, Miami, USA
| | - Eli Avisar
- Surgical Oncology, University of Miami, Miller School of Medicine, Miami, USA
| |
Collapse
|
21
|
Makey IA, El-Sayed Ahmed MM, Jacob S. The Radial Stapler Facilitates Lung-Conserving Wedge Resections. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2020; 15:463-467. [PMID: 32790513 DOI: 10.1177/1556984520942370] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
OBJECTIVE To test whether use of the radial stapler facilitates lung-conserving wedge resections compared to the linear stapler. METHODS A video-assisted thoracoscopic simulation lab was established to compare wedge resections performed only with linear staplers to wedge resections performed with the option of a radial stapler. Preserved sheep lungs were used. The target was a 0.5 cm mark on an ovoid surface of the lung equidistant from all edges. Seven fully trained cardiothoracic surgeons participated. They were instructed to obtain at least a 1 cm margin in all directions from the mark. The surgeons were allowed to work from only 2 preassigned ports. Each resected specimen was weighed. The resection margin was the shortest distance measured from the edge of the mark to the staple line. The mass-to-margin ratio was defined as the mass of the specimen divided by the length of the margin. The results were analyzed using a t-test for 2 independent means. RESULTS The 17 radial resections demonstrated a significantly better mass-to-margin ratio (3.31 [SD = 1.19]) compared to the 11 linear resections (4.75 [SD = 1.32], t[26] = 3, P = 0.006). CONCLUSIONS In a thoracoscopic simulation, the option of a radial stapler allowed for a better mass-to-margin resection of a small target from a broad surface of the lung than a linear stapler-only option.
Collapse
Affiliation(s)
- Ian A Makey
- 23389 Department of Cardiothoracic Surgery, Mayo Clinic Florida, Jacksonville, FL, USA
| | | | - Samuel Jacob
- 23389 Department of Cardiothoracic Surgery, Mayo Clinic Florida, Jacksonville, FL, USA
| |
Collapse
|
22
|
Tasdöven I, Karadeniz Çakmak G, Emre AU, Engin H, Bahadır B, Bakkal HB, Güllüoğlu MB. Intraoperative ultrasonography-guided surgery: An effective modality for breast conservation after neo-adjuvant chemotherapy. Breast J 2020; 26:1680-1687. [PMID: 33443786 DOI: 10.1111/tbj.13992] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Revised: 06/05/2020] [Accepted: 07/10/2020] [Indexed: 11/28/2022]
Abstract
Margin status is one of the significant prognostic factors for recurrence in breast-conserving surgery (BCS). The issue that merits consideration for oncologic safety and cost-effectiveness about the modalities to assure clear margins at initial surgical intervention remains controversial after neo-adjuvant chemotherapy (NAC). The presented study aimed to assess the impact of intraoperative ultrasound (IOUS)-guided surgery on accurate localization of tumor site, adequacy of excision with clear margins, and healthy tissue sacrifice in BCS after NAC. Patients who had IOUS-guided BCS ater NAC were reviewed. No patient had preoperative localization with wire or radiotracer. Intraoperative real-time sonographic localization, sonographic margin assessment during resection, macroscopic and sonographic examination of specimen, and cavity shavings (CS) were done as the standard procedure. No frozen assessment was performed. One hundred ninety-four patients were included, in which 42.5% had pCR. IOUS-guided surgery accomplished successful localization of the targeted lesions in all patients. Per protocol, all inked margins on CS specimens were reported to be tumor-free in permanent histopathology. No re-excision or mastectomy was required. For a setting without CS, the negative predictive value (NPV) of IOUS rate was 96%. IOUS was found to over and underestimate tumor response to NAC both in 2% of patients. IOUS-guided surgery seems to be an efficient modality to perform adequate BCS after NAC with no additional localization method. Especially, when CS is integrated as a standard to BCS, IOUS seems to provide safe surgery for patients with no false negativity and a high rate of NPV.
Collapse
Affiliation(s)
- Ilhan Tasdöven
- Department of Surgery, The School of Medicine, Zonguldak Bulent Ecevit University, Zonguldak, Turkey
| | - Güldeniz Karadeniz Çakmak
- Department of Surgery, The School of Medicine, Zonguldak Bulent Ecevit University, Zonguldak, Turkey
| | - Ali Ugur Emre
- Department of Surgery, The School of Medicine, Zonguldak Bulent Ecevit University, Zonguldak, Turkey
| | - Hüseyin Engin
- Department of Oncology, The School of Medicine, Zonguldak Bulent Ecevit University, Zonguldak, Turkey
| | - Burak Bahadır
- Department of Pathology, The School of Medicine, Zonguldak Bulent Ecevit University, Zonguldak, Turkey
| | - Hakan Bekir Bakkal
- Department of Radiation Oncology, The School of Medicine, Zonguldak Bulent Ecevit University, Zonguldak, Turkey
| | | |
Collapse
|
23
|
Civil YA, Duvivier KM, Perin P, Baan AH, van der Velde S. Optimization of Wire-guided Technique With Bracketing Reduces Resection Volumes in Breast-conserving Surgery for Early Breast Cancer. Clin Breast Cancer 2020; 20:e749-e756. [PMID: 32653472 DOI: 10.1016/j.clbc.2020.04.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Accepted: 04/26/2020] [Indexed: 11/16/2022]
Abstract
BACKGROUND Wire-guided localization (WGL) of early breast cancer can be facilitated using multiple wires, which is called bracketing wire-guided localization (BWL). The primary aim of this study is to compare BWL and conventional WGL regarding minimization of resection volumes without compromising margin status. Secondly, BWL is evaluated as an alternative method for intraoperative ultrasound (US) guidance in poorly definable breast tumors on US. PATIENTS AND METHODS In this retrospective cohort study, patients with preoperatively diagnosed breast cancer undergoing wide local excision between January 2016 and December 2018 were analyzed. Patients with multifocal disease or neoadjuvant treatment were excluded from this study. Optimal resection with minimal healthy breast tissue removal was assessed using the calculated resection ratio (CRR). RESULTS BWL was performed in 17 (9%) patients, WGL in 44 (22%), and US in 139 (70%). The rate of negative margins was comparable in all 3 groups. The CRR was significantly smaller for BWL (0.6) than WGL (1.3) in tumors larger than 1.5 cm. Additionally, BWL (0.8) led to smaller CRRs than US (1.7). This could be explained by the high number of small tumors (≤ 1.5 cm) in the US group for which greater CRRs are obtained than for large tumors (> 1.5 cm) (1.9 vs. 1.4; P = .005). CONCLUSION For breast tumors larger than 1.5 cm, BWL achieves more optimal resection volumes without compromising margin status compared with WGL. Moreover, BWL seems a suitable alternative to US in patients with poorly ultrasound-visible breast tumors and patients with a small tumor in a (large) breast.
Collapse
Affiliation(s)
- Yasmin A Civil
- Department of Surgical Oncology, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Katya M Duvivier
- Department of Radiology, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Paola Perin
- Department of Surgery, Ziekenhuis Amstelland, Amstelveen, The Netherlands
| | - Astrid H Baan
- Department of Surgery, Ziekenhuis Amstelland, Amstelveen, The Netherlands
| | - Susanne van der Velde
- Department of Surgical Oncology, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands.
| |
Collapse
|
24
|
Lee CY, Chang TF, Chou YH, Yang KC. Fully automated lesion segmentation and visualization in automated whole breast ultrasound (ABUS) images. Quant Imaging Med Surg 2020; 10:568-584. [PMID: 32269918 DOI: 10.21037/qims.2020.01.12] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Background The number of breast cancer patients has increased each year, and the demand for breast cancer detection has become quite large. There are many common breast cancer diagnostic tools. The latest automated whole breast ultrasound (ABUS) technology can obtain a complete breast tissue structure, which improves breast cancer detection technology. However, due to the large amount of ABUS image data, manual interpretation is time-consuming and labor-intensive. If there are lesions in multiple images, there may be some omissions. In addition, if further volume information or the three-dimensional shape of the lesion is needed for therapy, it is necessary to manually segment each lesion, which is inefficient for diagnosis. Therefore, automatic lesion segmentation for ABUS is an important issue for guiding therapy. Methods Due to the amount of speckle noise in an ultrasonic image and the low contrast of the lesion boundary, it is quite difficult to automatically segment the lesion. To address the above challenges, this study proposes an automated lesion segmentation algorithm. The architecture of the proposed algorithm can be divided into four parts: (I) volume of interest selection, (II) preprocessing, (III) segmentation, and (IV) visualization. A volume of interest (VOI) is automatically selected first via a three-dimensional level-set, and then the method uses anisotropic diffusion to address the speckled noise and intensity inhomogeneity correction to eliminate shadowing artifacts before the adaptive distance regularization level set method (DRLSE) conducts segmentation. Finally, the two-dimensional segmented images are reconstructed for visualization in the three-dimensional space. Results The ground truth is delineated by two radiologists with more than 10 years of experience in breast sonography. In this study, three performance assessments are carried out to evaluate the effectiveness of the proposed algorithm. The first assessment is the similarity measurement. The second assessment is the comparison of the results of the proposed algorithm and the Chan-Vese level set method. The third assessment is the volume estimation of phantom cases. In this study, in the 2D validation of the first assessment, the area Dice similarity coefficients of the real cases named cases A, real cases B and phantoms are 0.84±0.02, 0.86±0.03 and 0.92±0.02, respectively. The overlap fraction (OF) and overlap value (OV) of the real cases A are 0.84±0.06 and 0.78±0.04, real case B are 0.91±0.04 and 0.82±0.05, respectively. The overlap fraction (OF) and overlap value (OV) of the phantoms are 0.95±0.02 and 0.92±0.03, respectively. In the 3D validation, the volume Dice similarity coefficients of the real cases A, real cases B and phantoms are 0.85±0.02, 0.89±0.04 and 0.94±0.02, respectively. The overlap fraction (OF) and overlap value (OV) of the real cases A are 0.82±0.06 and 0.79±0.04, real cases B are 0.92±0.04 and 0.85±0.07, respectively. The overlap fraction (OF) and overlap value (OV) of the phantoms are 0.95±0.01 and 0.93±0.04, respectively. Therefore, the proposed algorithm is highly reliable in most cases. In the second assessment, compared with Chan-Vese level set method, the Dice of the proposed algorithm in real cases A, real cases B and phantoms are 0.84±0.02, 0.86±0.03 and 0.92±0.02, respectively. The Dice of Chan-Vese level set in real cases A, real cases B and phantoms are 0.65±0.23, 0.69±0.14 and 0.76±0.14, respectively. The Dice performance of different methods on segmentation shows a highly significant impact (P<0.01). The results show that the proposed algorithm is more accurate than Chan-Vese level set method. In the third assessment, the Spearman's correlation coefficient between the segmented volumes and the corresponding ground truth volumes is ρ=0.929 (P=0.01). Conclusions In summary, the proposed method can batch process ABUS images, segment lesions, calculate their volumes and visualize lesions to facilitate observation by radiologists and physicians.
Collapse
Affiliation(s)
- Chia-Yen Lee
- Department of Electrical Engineering, National United University, Taipei, Taiwan
| | - Tzu-Fang Chang
- Department of Electrical Engineering, National United University, Taipei, Taiwan
| | - Yi-Hong Chou
- Department of Medical Imaging and Radiological Technology, Yuanpei University of Medical Technology, Hsinchu, Taiwan.,Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan.,School of Medicine, National Yang Ming University, Taipei, Taiwan
| | - Kuen-Cheh Yang
- Department of Family Medicine, National Taiwan University Hospital, Bei-Hu Branch, Taipei, Taiwan
| |
Collapse
|
25
|
Krishna KL, Srinath BS, Santosh D, Velusamy S, Divyamala KP, Sariya Mohammadi J, Kurpad V, Kulkarni S, Yaji P, Goud S, Dhanireddy S, Ram J. A comparative study of perioperative techniques to attain negative margins and spare healthy breast tissue in breast conserving surgery. Breast Dis 2020; 39:127-135. [PMID: 32831188 DOI: 10.3233/bd-200443] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
BACKGROUND AND AIM Traditionally lumpectomy as a part of breast-conserving surgery (BCS) is performed by palpation-guided method leading to positive margins and large excision volumes. There is no evidence suggesting that wide margin excisions decrease intra-breast tumour recurrence. Various perioperative techniques are used for margin assessment. We aimed to compare three commonly used techniques, i.e., ultrasound-guided surgery, palpation-guided surgery and cavity shaving for attaining negative margins and estimating the extent of healthy breast tissue resection. METHOD A prospective comparative study was performed on 90 patients who underwent breast conservation surgery for early breast cancer between August 2018 and June 2019. Tumour excision with a minimum of 1 cm margin was done either using ultrasound, palpation or cavity shaving. Histopathological evaluation was done to assess the margin status and excess amount of resected normal breast tissue. Calculated resection ratio (CRR) defining the excess amount of the resected breast tissue was achieved by dividing the total resection volume (TRV) by optimal resection volume (ORV). The time taken for excision was also recorded. RESULTS Histopathology of all 90 patients (30 in each group) revealed a negative resection margin in 93.3% of 30 patients in palpation-guided surgery group and 100% in both ultrasound-guided surgery and cavity shaving groups. Two patients (6.7%) from the cavity shaving group had positive margins on initial lumpectomy but shave margins were negative. TRV was significantly less in the ultrasound-guided surgery group compared to the palpation-guided surgery group and cavity shaving group (76.9 cm3, 94.7 cm3 and 126.3 cm3 respectively; p < 0.0051). CRR was 1.2 in ultrasound group compared to 1.9 in palpation group and 2.1 in cavity shave group which was also statistically significant (p < 0.0001).Excision time was significantly less (p < 0.001) in palpation-guided surgery group (13.8 min) compared to cavity shaving group (15.1 min) and ultrasound-guided group (19.4 min). CONCLUSION Ultrasound-guided surgery is more accurate in attaining negative margins with the removal of least amount of healthy breast tissue compared to palpation-guided surgery and cavity shaving.
Collapse
Affiliation(s)
- Kanyadhara Lohita Krishna
- Department of Surgical Oncology, Sri Shankara Cancer Hospital and Research Centre, Basavangudi, Bangalore, Karnataka, India
| | - B S Srinath
- Department of Surgical Oncology, Sri Shankara Cancer Hospital and Research Centre, Basavangudi, Bangalore, Karnataka, India
| | - Divya Santosh
- Department of Breast Radiology, Sri Shankara Cancer Hospital and Research Centre, Basavangudi, Bangalore, Karnataka, India
| | - Shanthi Velusamy
- Department of Pathology, Sri Shankara Cancer Hospital and Research Centre, Basavangudi, Bangalore, Karnataka, India
| | - K P Divyamala
- Department of Pathology, Sri Shankara Cancer Hospital and Research Centre, Basavangudi, Bangalore, Karnataka, India
| | - J Sariya Mohammadi
- Department of Surgical Oncology, Sri Shankara Cancer Hospital and Research Centre, Basavangudi, Bangalore, Karnataka, India
| | - Vishnu Kurpad
- Department of Surgical Oncology, Sri Shankara Cancer Hospital and Research Centre, Basavangudi, Bangalore, Karnataka, India
| | - Sanjeev Kulkarni
- Department of Surgical Oncology, Sri Shankara Cancer Hospital and Research Centre, Basavangudi, Bangalore, Karnataka, India
| | - Prabhat Yaji
- Department of Surgical Oncology, Sri Shankara Cancer Hospital and Research Centre, Basavangudi, Bangalore, Karnataka, India
| | - Sandeep Goud
- Department of Surgical Oncology, Sri Shankara Cancer Hospital and Research Centre, Basavangudi, Bangalore, Karnataka, India
| | - Subhashini Dhanireddy
- Department of Surgical Oncology, Sri Shankara Cancer Hospital and Research Centre, Basavangudi, Bangalore, Karnataka, India
| | | |
Collapse
|
26
|
Gauvin G, Yeo CT, Ungi T, Merchant S, Lasso A, Jabs D, Vaughan T, Rudan JF, Walker R, Fichtinger G, Engel CJ. Real-time electromagnetic navigation for breast-conserving surgery using NaviKnife technology: A matched case-control study. Breast J 2019; 26:399-405. [PMID: 31531915 DOI: 10.1111/tbj.13480] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2019] [Revised: 05/20/2019] [Accepted: 05/23/2019] [Indexed: 11/28/2022]
Abstract
Breast-conserving surgery (BCS) is a mainstay in breast cancer treatment. For nonpalpable breast cancers, current strategies have limited accuracy, contributing to high positive margin rates. We developed NaviKnife, a surgical navigation system based on real-time electromagnetic (EM) tracking. The goal of this study was to confirm the feasibility of intraoperative EM navigation in patients with nonpalpable breast cancer and to assess the potential value of surgical navigation. We recruited 40 patients with ultrasound visible, single, nonpalpable lesions, undergoing BCS. Feasibility was assessed by equipment functionality and sterility, acceptable duration of the operation, and surgeon feedback. Secondary outcomes included specimen volume, positive margin rate, and reoperation outcomes. Study patients were compared to a control group by a matched case-control analysis. There was no equipment failure or breach of sterility. The median operative time was 66 (44-119) minutes with NaviKnife vs 65 (34-158) minutes for the control (P = .64). NaviKnife contouring time was 3.2 (1.6-9) minutes. Surgeons rated navigation as easy to setup, easy to use, and useful in guiding nonpalpable tumor excision. The mean specimen volume was 95.4 ± 73.5 cm3 with NaviKnife and 140.7 ± 100.3 cm3 for the control (P = .01). The positive margin rate was 22.5% with NaviKnife and 28.7% for the control (P = .52). The re-excision specimen contained residual disease in 14.3% for NaviKnife and 50% for the control (P = .28). Our results demonstrate that real-time EM navigation is feasible in the operating room for BCS. Excisions performed with navigation result in the removal of less breast tissue without compromising postive margin rates.
Collapse
Affiliation(s)
- Gabrielle Gauvin
- Department of Surgery, Queen's University, Kingston, ON, Canada.,Department of Surgical Oncology, Fox Chase Cancer Center, Philadelphia, Pennsylvania
| | - Caitlin T Yeo
- Department of Surgery, Queen's University, Kingston, ON, Canada
| | - Tamas Ungi
- School of Computing, Queen's University, Kingston, ON, Canada
| | - Shaila Merchant
- Department of Surgery, Queen's University, Kingston, ON, Canada
| | - Andras Lasso
- School of Computing, Queen's University, Kingston, ON, Canada
| | - Doris Jabs
- Department of Radiology, Queen's University, Kingston, ON, Canada
| | - Thomas Vaughan
- School of Computing, Queen's University, Kingston, ON, Canada
| | - John F Rudan
- Department of Surgery, Queen's University, Kingston, ON, Canada
| | - Ross Walker
- Department of Surgery, Queen's University, Kingston, ON, Canada
| | - Gabor Fichtinger
- Department of Surgery, Queen's University, Kingston, ON, Canada.,School of Computing, Queen's University, Kingston, ON, Canada
| | - Cecil Jay Engel
- Department of Surgery, Queen's University, Kingston, ON, Canada
| |
Collapse
|
27
|
Elfgen C, Papassotiropoulos B, Varga Z, Moskovszky L, Nap M, Güth U, Baege A, Amann E, Chiesa F, Tausch C. Comparative analysis of confocal microscopy on fresh breast core needle biopsies and conventional histology. Diagn Pathol 2019; 14:58. [PMID: 31202280 PMCID: PMC6570850 DOI: 10.1186/s13000-019-0835-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2019] [Accepted: 06/05/2019] [Indexed: 12/20/2022] Open
Abstract
Background Evaluation of core needle biopsies (CNB) is a standard procedure for the diagnosis of breast cancer. However, tissue processing and image preparation is a time- consuming procedure and instant on-site availability of high-quality images could substantially improve the efficacy of the diagnostic procedure. Conventional microscopic methods, such as frozen section analysis (FSA) for detection of malignant cells still have clear disadvantages. In the present study, we tested a confocal microscopy scanner on fresh tissue from CNB with intention to develop an alternative device to FSA in clinical practice. Patients and methods In 24 patients with suspicious breast lesions standard of care image-guided biopsies were performed. Confocal images have been obtained using the Histolog™ Scanner and evaluated by two independent pathologists. Hematoxylin-Eosin (H&E) histological sections of the biopsies were routinely processed in a blinded fashion with respect to the confocal images. Results In total 42 confocal images were generated from 24 biopsy specimens, and available for analysis within a few minutes of taking the biopsy. This resulted in 2 × 42 = 84 pathologic evaluations. In four cases, a pathologic diagnosis was not possible with confocal microscopy. An exact correlation based on the B-classification was reached in 41 out of 80 examinations and in another 35 cases in a broader sense of correspondence definition (i.e. malignant vs. benign). Conclusions As a reliable on-site method, the Histolog™ Scanner provides a visualization of cellular details equivalent to the H&E standards, permitting rapid and accurate diagnosis of malignant and benign breast lesions. Furthermore, this device offers great potential for immediate margin analysis of specimen in breast conserving therapy.
Collapse
Affiliation(s)
- C Elfgen
- Breast Center Zurich, Seefeldstrasse 214, 8008, Zürich, Switzerland. .,Institute of Gynecology and Obstetrics, Senology Department, University of Witten-Herdecke, Witten, Germany.
| | | | - Z Varga
- Institute of Pathology and Molecular Pathology, University Hospital Zurich, Zürich, Switzerland
| | - L Moskovszky
- Institute of Pathology and Molecular Pathology, University Hospital Zurich, Zürich, Switzerland
| | - M Nap
- Nap Pathology Consultance bv, Numandorp, The Netherlands
| | - U Güth
- Breast Center Zurich, Seefeldstrasse 214, 8008, Zürich, Switzerland
| | - A Baege
- Breast Center Zurich, Seefeldstrasse 214, 8008, Zürich, Switzerland
| | - E Amann
- Breast Center Zurich, Seefeldstrasse 214, 8008, Zürich, Switzerland
| | - F Chiesa
- Breast Center Zurich, Seefeldstrasse 214, 8008, Zürich, Switzerland
| | - C Tausch
- Breast Center Zurich, Seefeldstrasse 214, 8008, Zürich, Switzerland
| |
Collapse
|
28
|
Gerrard AD, Shrotri A. Surgeon-led Intraoperative Ultrasound Localization for Nonpalpable Breast Cancers: Results of 5 Years of Practice. Clin Breast Cancer 2019; 19:e748-e752. [PMID: 31208875 DOI: 10.1016/j.clbc.2019.05.008] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2019] [Accepted: 05/05/2019] [Indexed: 12/24/2022]
Abstract
BACKGROUND The uptake of breast screening has led to a rise in the number of nonpalpable breast cancer diagnoses. Breast conserving therapy (BCT) is the treatment of choice for early breast cancer, and this requires localization of the lesion. Commonly detection is achieved by wire-guided localization in the radiology department. This technique has complications and requires utilization of a radiologist. Intraoperative ultrasound (IOUS) has been shown to be a safe alternative, but there is little data on its use. The aim of this study is to report the use of surgeon-led IOUS over the past 5 years, assessing the ability to detect lesions and the re-excision rate for involved margins. PATIENTS AND METHODS A retrospective observational study was performed on consecutive patients undergoing IOUS-marked BCT between 2014 and 2018. The technique is described, and patients' records were reviewed to assess the histologic specimen reports and need for subsequent re-excision. RESULTS Ninety-five IOUS BCT operations were performed. Every cancer was identified by IOUS and removed. Fourteen margins were positive and required re-excision. Of these, only 2 contained residual tumor. CONCLUSION This is the first data from the United Kingdom for IOUS skin marking without wire localization. IOUS is a safe method of localization in BCT. It offers advantages both to the patient and the unit as it reduces pressure on the radiology department.
Collapse
Affiliation(s)
- Adam D Gerrard
- Breast Department, Aintree University Hospital NHS Foundation Trust, Liverpool, England
| | - Anu Shrotri
- Breast Department, Aintree University Hospital NHS Foundation Trust, Liverpool, England.
| |
Collapse
|
29
|
A combined, totally magnetic technique with a magnetic marker for non-palpable tumour localization and superparamagnetic iron oxide nanoparticles for sentinel lymph node detection in breast cancer surgery. Eur J Surg Oncol 2019; 45:544-549. [DOI: 10.1016/j.ejso.2018.10.064] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2018] [Revised: 10/16/2018] [Accepted: 10/17/2018] [Indexed: 11/20/2022] Open
|
30
|
Esgueva A, Rodríguez-Revuelto R, Espinosa-Bravo M, Salazar JP, Rubio IT. Learning curves in intraoperative ultrasound guided surgery in breast cancer based on complete breast cancer excision and no need for second surgeries. Eur J Surg Oncol 2019; 45:578-583. [DOI: 10.1016/j.ejso.2019.01.017] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2018] [Revised: 12/11/2018] [Accepted: 01/11/2019] [Indexed: 01/05/2023] Open
|
31
|
Carlino G, Rinaldi P, Giuliani M, Rella R, Bufi E, Padovano F, Ciardi C, Romani M, Belli P, Manfredi R. Ultrasound-guided preoperative localization of breast lesions: a good choice. J Ultrasound 2018; 22:85-94. [PMID: 30367356 DOI: 10.1007/s40477-018-0335-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2018] [Accepted: 10/11/2018] [Indexed: 12/31/2022] Open
Abstract
PURPOSE The aim of the study was to verify whether ultrasound (US)-guided preoperative localization of breast lesions is an adequate technique for correct and safe surgical resection and to contribute positively and effectively to this topic in the literature with our results. METHODS From June 2016 to November 2016, 155 patients with both benign and malignant breast lesions were selected from our institute to undergo US localization before surgery. The lesions included were: sonographically visible and nonpalpable lesions; palpable lesions for which a surgeon had requested US localization to better evaluate the site and extension; sonographically visible, multifocal breast lesions, both palpable and nonpalpable. US localization was performed using standard linear transducers (Siemens 18 L6, 5.5-8 MHz, 5.6 cm, ACUSON S2000 System, Siemens Medical Solutions). The radiologist used a skin pen to mark the site of the lesion, and the reported lesion's depth and distance from the nipple and pectoral muscle were recorded. The lesions were completely excised by a team of breast surgeons, and the surgical specimens were sent to the Radiology Department for radiological evaluation and to the Pathology Department for histological assessment. RESULTS In 155 patients who underwent to preoperative US localization, 188 lesions were found, and the location of each lesion was marked with a skin pen. A total of 181 lesions were confirmed by the final histopathologic exam (96.28%); 132 of them (72.92%) were malignant, and 124 of these (93.93%) showed free margins. CONCLUSIONS US-guided preoperative localization of sonographically visible breast lesions is a simple and nontraumatic procedure with high specificity and is a useful tool for obtaining accurate surgical margins.
Collapse
Affiliation(s)
- Giorgio Carlino
- Department of Radiology, Fondazione Policlinico A. Gemelli IRCCS - Università Cattolica Sacro Cuore, Largo Agostino Gemelli 8, 00168, Rome, Italy.
| | - Pierluigi Rinaldi
- Department of Radiology, Fondazione Policlinico A. Gemelli IRCCS - Università Cattolica Sacro Cuore, Largo Agostino Gemelli 8, 00168, Rome, Italy
| | - Michela Giuliani
- Department of Radiology, Fondazione Policlinico A. Gemelli IRCCS - Università Cattolica Sacro Cuore, Largo Agostino Gemelli 8, 00168, Rome, Italy
| | - Rossella Rella
- Department of Radiology, Fondazione Policlinico A. Gemelli IRCCS - Università Cattolica Sacro Cuore, Largo Agostino Gemelli 8, 00168, Rome, Italy
| | - Enida Bufi
- Department of Radiology, Fondazione Policlinico A. Gemelli IRCCS - Università Cattolica Sacro Cuore, Largo Agostino Gemelli 8, 00168, Rome, Italy
| | - Federico Padovano
- Department of Radiology, Fondazione Policlinico A. Gemelli IRCCS - Università Cattolica Sacro Cuore, Largo Agostino Gemelli 8, 00168, Rome, Italy
| | - Chiara Ciardi
- Department of Radiology, Fondazione Policlinico A. Gemelli IRCCS - Università Cattolica Sacro Cuore, Largo Agostino Gemelli 8, 00168, Rome, Italy
| | - Maurizio Romani
- Department of Radiology, Fondazione Policlinico A. Gemelli IRCCS - Università Cattolica Sacro Cuore, Largo Agostino Gemelli 8, 00168, Rome, Italy
| | - Paolo Belli
- Department of Radiology, Fondazione Policlinico A. Gemelli IRCCS - Università Cattolica Sacro Cuore, Largo Agostino Gemelli 8, 00168, Rome, Italy
| | - Riccardo Manfredi
- Department of Radiology, Fondazione Policlinico A. Gemelli IRCCS - Università Cattolica Sacro Cuore, Largo Agostino Gemelli 8, 00168, Rome, Italy
| |
Collapse
|
32
|
Lagendijk M, Vos EL, Ramlakhan KP, Verhoef C, Koning AHJ, van Lankeren W, Koppert LB. Breast and Tumour Volume Measurements in Breast Cancer Patients Using 3-D Automated Breast Volume Scanner Images. World J Surg 2018; 42:2087-2093. [PMID: 29299647 PMCID: PMC5990576 DOI: 10.1007/s00268-017-4432-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND The resection volume in relation to the breast volume is known to influence cosmetic outcome following breast-conserving therapy. It was hypothesised that three-dimensional ultrasonography (3-D US) could be used to preoperatively assess breast and tumour volume and show high association with histopathological measurements. METHODS Breast volume by the 3D-US was compared to the water displacement method (WDM), mastectomy specimen weight, 3-D MRI and three different calculations for breast volume on mammography. Tumour volume by the 3-D US was compared to the histopathological tumour volume and 3-D MRI. Relatedness was based on the intraclass correlation coefficient (ICC) with corresponding 95% confidence interval (95% CI). Bland-Altman plots were used to graphically display the agreement for the different assessment techniques. All measurements were performed by one observer. RESULTS A total of 36 patients were included, 20 and 23 for the evaluation of breast and tumour volume (ductal invasive carcinomas), respectively. 3-D US breast volume showed 'excellent' association with WDM, ICC 0.92 [95% CI (0.80-0.97)]. 3-D US tumour volume showed a 'excellent' association with histopathological tumour volume, ICC 0.78 [95% CI (0.55-0.91)]. Bland-Altman plots showed an increased overestimation in lager tumour volumes measured by 3-D MRI compared to histopathological volume. CONCLUSIONS 3-D US showed a high association with gold standard WDM for the preoperative assessment of breast volume and the histopathological measurement of tumour volume. 3-D US is an patient-friendly preoperative available technique to calculate both breast volume and tumour volume. Volume measurements are promising in outcome prediction of intended breast-conserving treatment.
Collapse
Affiliation(s)
- M Lagendijk
- Department of Surgical Oncology, Erasmus MC Cancer Institute, Groene Hilledijk 301, 3075 EA, Rotterdam, The Netherlands.
- Department of Surgical Oncology, Erasmus MC Cancer Institute, PO Box 5201, 3008 AE, Rotterdam, The Netherlands.
| | - E L Vos
- Department of Surgical Oncology, Erasmus MC Cancer Institute, Groene Hilledijk 301, 3075 EA, Rotterdam, The Netherlands
| | - K P Ramlakhan
- Department of Surgical Oncology, Erasmus MC Cancer Institute, Groene Hilledijk 301, 3075 EA, Rotterdam, The Netherlands
| | - C Verhoef
- Department of Surgical Oncology, Erasmus MC Cancer Institute, Groene Hilledijk 301, 3075 EA, Rotterdam, The Netherlands
| | - A H J Koning
- Department of Bio-informatics, Erasmus MC, 's-Gravendijkwal 230, 3015 CE, Rotterdam, The Netherlands
| | - W van Lankeren
- Department of Radiology, Erasmus MC, 's-Gravendijkwal 230, 3015 CE, Rotterdam, The Netherlands
| | - L B Koppert
- Department of Surgical Oncology, Erasmus MC Cancer Institute, Groene Hilledijk 301, 3075 EA, Rotterdam, The Netherlands
| |
Collapse
|
33
|
Merrill AY, Ochoa D, Klimberg VS, Hill EL, Preston M, Neisler K, Henry-Tillman RS. Cutting Healthcare Costs with Hematoma-Directed Ultrasound-Guided Breast Lumpectomy. Ann Surg Oncol 2018; 25:3076-3081. [DOI: 10.1245/s10434-018-6596-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2018] [Indexed: 12/28/2022]
|
34
|
Green M, Vidya R. Techniques Used to Localize Occult Breast Lesions: An Update. Clin Breast Cancer 2018; 18:e281-e283. [DOI: 10.1016/j.clbc.2018.01.001] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2017] [Accepted: 01/01/2018] [Indexed: 11/16/2022]
|
35
|
Abstract
Breast-conserving surgery (BCS) followed by radiation therapy is the current standard of care for early stage breast cancer. Successful BCS necessitates complete tumor resection with clear margins at the pathologic assessment of the specimen ("no ink on tumor"). The presence of positive margins warrants additional surgery to obtain negative final margins, which has significant physical, psychological, and financial implications for the patient. The challenge lies in developing accurate real-time intraoperative margin assessment techniques to minimize the presence of "ink on tumor" and the subsequent need for additional surgery.
Collapse
|
36
|
Li X, Zhu D, Li M, Zhao Z. Ectopic breast localization wire in the pleural cavity: A case report. Mol Clin Oncol 2018; 8:686-688. [PMID: 29725536 DOI: 10.3892/mco.2018.1593] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2017] [Accepted: 09/11/2017] [Indexed: 11/06/2022] Open
Abstract
Ultrasound is an easily accessible and cost-effective imaging method that is not associated with radiation exposure. Ultrasound-guided wire localization is a reliable method for resecting non-palpable breast lesions. Preoperative ultrasound-guided wire localization has the advantage of a shorter operative time, and the breast lesions may be accurately excised with less tissue injury. We herein report an unusual case of an ectopic breast localization wire in the pleural cavity in a 47-year-old female patient with a history of right-sided breast cancer, who received left segmental mastectomy due to a newly identified left-sided breast lesion. The wire was identified with intraoperative X-ray and computed tomography imaging and was successfully removed under thoracoscopic guidance. The patient recovered uneventfully. To the best of our knowledge, this is the first report on localization wire-related complications in the English literature.
Collapse
Affiliation(s)
- Xuelu Li
- Department of Breast Surgery and Oncology, The Second Hospital of Dalian Medical University, Dalian, Liaoning 116027, P.R. China
| | - Dandan Zhu
- Department of Critical Care Medicine, The Second Hospital of Dalian Medical University, Dalian, Liaoning 116027, P.R. China
| | - Man Li
- Department of Breast Surgery and Oncology, The Second Hospital of Dalian Medical University, Dalian, Liaoning 116027, P.R. China
| | - Zuowei Zhao
- Department of Breast Surgery and Oncology, The Second Hospital of Dalian Medical University, Dalian, Liaoning 116027, P.R. China
| |
Collapse
|
37
|
Struk S, Honart JF, Qassemyar Q, Leymarie N, Sarfati B, Alkhashnam H, Mazouni C, Rimareix F, Kolb F. Utilisation du vert d’indocyanine en chirurgie sénologique et reconstruction mammaire. ANN CHIR PLAST ESTH 2018; 63:54-61. [DOI: 10.1016/j.anplas.2017.09.008] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2017] [Accepted: 09/25/2017] [Indexed: 12/21/2022]
|
38
|
Shin YD, Choi YJ, Kim DH, Park SS, Choi H, Kim DJ, Park S, Yun HY, Song YJ. Comparison of outcomes of surgeon-performed intraoperative ultrasonography-guided wire localization and preoperative wire localization in nonpalpable breast cancer patients undergoing breast-conserving surgery: A retrospective cohort study. Medicine (Baltimore) 2017; 96:e9340. [PMID: 29390405 PMCID: PMC5815817 DOI: 10.1097/md.0000000000009340] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Abstract
This study aimed to determine the efficacy of intraoperative ultrasonography-guided wire localization guided breast-conserving surgery (BCS) for nonpalpable breast cancer and compare it to conventional preoperative wire localization (PWL) guided surgery.We retrospectively analyzed the medical charts of 214 consecutive nonpalpable breast cancer patients who underwent BCS using intraoperative ultrasonography-guided wire localization by a surgeon (IUWLS) and PWL, between April 2013 and March 2017. Positive surgical margins, reexcision rates, and resection volumes were investigated.Of the total cohort, 124 patients underwent BCS with IUWLS and 90 patients with PWL. The following did not differ between the IUWLS and PWL groups: positive margin status, re-excision rate, conversion rate, permanent positive margin status, reoperation rate, median optimal resection volume (ORV), median total resection volume (TRV), and median closest tumor-free margin. Rather, median (range) widest tumor-free margin was significantly smaller in the IUWLS group (9 mm [5-12]) than in the PWL group (14 mm [9-20]; P = .003]). Median (range) calculated resection ratio (CRR) was significantly lower in the IUWLS group (1.67 [0.87-9.38]) than in the PWL group (4.83 [1.63-21.04]; P = .02).In nonpalpable breast cancer patients undergoing BCS, IUWLS showed positive resection margins and reexcision rates equivalent to those of the conventional PWL method. Additionally, excision volume and widest tumor-free margin were smaller with IUWLS, confirming that healthy breast tissue is less likely to be resected with this method. Our results suggest that IUWLS offers an excellent alternative to PWL, while avoiding PWL-induced patient discomfort.
Collapse
Affiliation(s)
| | - Young Jin Choi
- Department of Surgery, Chungbuk National University Hospital, Chungbuk National University College of Medicine, Cheongju, Republic of Korea
| | - Dae Hoon Kim
- Department of Surgery, Chungbuk National University Hospital, Chungbuk National University College of Medicine, Cheongju, Republic of Korea
| | - Sung Su Park
- Department of Surgery, Chungbuk National University Hospital, Chungbuk National University College of Medicine, Cheongju, Republic of Korea
| | - Hanlim Choi
- Department of Surgery, Chungbuk National University Hospital, Chungbuk National University College of Medicine, Cheongju, Republic of Korea
| | - Dong Ju Kim
- Department of Surgery, Chungbuk National University Hospital, Chungbuk National University College of Medicine, Cheongju, Republic of Korea
| | - Sungmin Park
- Department of Surgery, Chungbuk National University Hospital, Chungbuk National University College of Medicine, Cheongju, Republic of Korea
| | - Hyo Yung Yun
- Department of Surgery, Chungbuk National University Hospital, Chungbuk National University College of Medicine, Cheongju, Republic of Korea
| | - Young Jin Song
- Department of Surgery, Chungbuk National University Hospital, Chungbuk National University College of Medicine, Cheongju, Republic of Korea
| |
Collapse
|
39
|
Krekel NMA, Haloua MH, Volders JH, Meijer S, van den Tol MP. Response to “The CUBE Technique: Continuous Ultrasound-Guided Breast Excision,” Published in August 2014 by Tummel et al. Amsterdam, 28th January 2015. Ann Surg Oncol 2017; 24:578. [DOI: 10.1245/s10434-017-6161-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2017] [Indexed: 11/18/2022]
|
40
|
Peek MCL, Ahmed M, Scudder J, Baker R, Charalampoudis P, Pinder SE, Douek M. High-intensity focused ultrasound in the treatment of breast fibroadenomata (HIFU-F trial). Int J Hyperthermia 2017; 34:1002-1009. [PMID: 28854826 DOI: 10.1080/02656736.2017.1373865] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
BACKGROUND High-intensity focussed ultrasound (HIFU) is a non-invasive ablative technique utilising the application of high frequency ultrasound (US) pressure waves to cause tissue necrosis. This emerging technology is currently limited by prolonged treatment times. The aim of the HIFU-F trial was to perform circumferential HIFU treatment as a means of shortening treatment times. METHODS A prospective trial was set up to treat 50 consecutive patients ≥18 years of age. Eligible patients possessed symptomatic fibroadenomata, visible on US. Patients ≥25 years of age required histological confirmation of the diagnosis. Primary outcome measures were reduction in treatment time, reduction in volume on US after 12 months and complication rates. RESULTS HIFU treatment was performed in 51 patients (53 treatments) with a mean age of 29.8 years (SD 7.2 years) and a diameter of 2.6 cm (SD 1.4 cm). Circumferential ablation reduced treatment times by an estimated 19.9 min (SD 25.1 min), which is a 29.4% (SD 15.2%) reduction compared with whole lesion ablation. Volume reduction of 43.2% (SD 35.4%; p < 0.005, paired t-test) was observed on US at 12 months post-treatment. Local complications completely resolved at 1 month apart from skin hyper-pigmentation, which persisted in nine cases at three months, six cases at 6 months and six at 12 months. CONCLUSION Circumferential HIFU treatment for breast fibroadenomata is feasible to reduce both lesion size and treatment time. HIFU is a non-invasive alternative technique for the treatment of breast fibroadenomata. ISRCTN registration: 76622747.
Collapse
Affiliation(s)
- M C L Peek
- a Division of Cancer Studies , King's College London, Guy's Hospital Campus , London , Great Britain.,b Guy's and St. Thomas' NHS Foundation Trust , London , Great Britain
| | - M Ahmed
- a Division of Cancer Studies , King's College London, Guy's Hospital Campus , London , Great Britain.,b Guy's and St. Thomas' NHS Foundation Trust , London , Great Britain
| | - J Scudder
- b Guy's and St. Thomas' NHS Foundation Trust , London , Great Britain
| | - R Baker
- c School of Business , University of Salford , Salford , Great Britain
| | - P Charalampoudis
- b Guy's and St. Thomas' NHS Foundation Trust , London , Great Britain
| | - S E Pinder
- a Division of Cancer Studies , King's College London, Guy's Hospital Campus , London , Great Britain.,b Guy's and St. Thomas' NHS Foundation Trust , London , Great Britain
| | - M Douek
- a Division of Cancer Studies , King's College London, Guy's Hospital Campus , London , Great Britain.,b Guy's and St. Thomas' NHS Foundation Trust , London , Great Britain
| | | |
Collapse
|
41
|
Voiculescu Ș, Scăunașu RV, Moroșanu M, Greșanu A, Popescu B, Burcos T. The combined use of senometry and ultrasonography for breast cancer surgical planning. JOURNAL OF CLINICAL AND INVESTIGATIVE SURGERY 2017. [DOI: 10.25083/2559.5555.22.8893] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Objective. Ultrasound exerts an important role in breast cancer diagnosis protocol, but the use of eco-senometry can also improve therapeutic options, surgical planning and technique. Methods. We describe various measurement formulas and techniques that are applied in order to acquire important information regarding the breast and its lesions. Results. Senometry and ultrasonography have been proven to be very effective, reaching up to reliability levels as high as 0.997 and accuracy levels as high as 99.6%. Conclusions. Senometry and ultrasonography have clearly demonstrated their value in breast cancer diagnosis and treatment. These methods are reliable, inexpensive and can be easily performed by the surgeon. More advances in the domain are expected in the future.
Collapse
|
42
|
Karadeniz Cakmak G, Emre AU, Tascilar O, Bahadir B, Ozkan S. Surgeon performed continuous intraoperative ultrasound guidance decreases re-excisions and mastectomy rates in breast cancer. Breast 2017; 33:23-28. [DOI: 10.1016/j.breast.2017.02.014] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2016] [Revised: 12/11/2016] [Accepted: 02/22/2017] [Indexed: 01/14/2023] Open
|
43
|
Schermers B, van der Hage JA, Loo CE, Vrancken Peeters MTFD, Winter-Warnars HAO, van Duijnhoven F, Ten Haken B, Muller SH, Ruers TJM. Feasibility of magnetic marker localisation for non-palpable breast cancer. Breast 2017; 33:50-56. [PMID: 28282587 DOI: 10.1016/j.breast.2017.03.003] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2016] [Revised: 03/01/2017] [Accepted: 03/02/2017] [Indexed: 12/22/2022] Open
Abstract
OBJECTIVES Accurate tumour localisation is essential for breast-conserving surgery of non-palpable tumours. Current localisation technologies are associated with disadvantages such as logistical challenges and migration issues (wire guided localisation) or legislative complexities and high administrative burden (radioactive localisation). We present MAgnetic MArker LOCalisation (MaMaLoc), a novel technology that aims to overcome these disadvantages using a magnetic marker and a magnetic detection probe. This feasibility study reports on the first experience with this new technology for breast cancer localisation. MATERIALS AND METHODS Fifteen patients with unifocal, non-palpable breast cancer were recruited. They received concurrent placement of the magnetic marker in addition to a radioactive iodine seed, which is standard of care in our clinic. In a subset of five patients, migration of the magnetic marker was studied. During surgery, a magnetic probe and gammaprobe were alternately used to localise the markers and guide surgery. The primary outcome parameter was successful transcutaneous identification of the magnetic marker. Additionally, data on radiologist and surgeon satisfaction were collected. RESULTS Magnetic marker placement was successful in all cases. Radiologists could easily adapt to the technology in the clinical workflow. Migration of the magnetic marker was negligible. The primary endpoint of the study was met with an identification rate of 100%. Both radiologists and surgeons reflected that the technology was intuitive to use and that it was comparable to radioactive iodine seed localisation. CONCLUSION Magnetic marker localisation for non-palpable breast cancer is feasible and safe, and may be a viable non-radioactive alternative to current localisation technologies.
Collapse
Affiliation(s)
- B Schermers
- The Netherlands Cancer Institute, Department of Surgery, The Netherlands; University of Twente, MIRA Institute, The Netherlands.
| | - J A van der Hage
- The Netherlands Cancer Institute, Department of Surgery, The Netherlands
| | - C E Loo
- The Netherlands Cancer Institute, Department of Radiology, Division of Diagnostic Oncology, The Netherlands
| | | | - H A O Winter-Warnars
- The Netherlands Cancer Institute, Department of Radiology, Division of Diagnostic Oncology, The Netherlands
| | - F van Duijnhoven
- The Netherlands Cancer Institute, Department of Surgery, The Netherlands
| | - B Ten Haken
- University of Twente, MIRA Institute, The Netherlands
| | - S H Muller
- The Netherlands Cancer Institute, Department of Clinical Physics, The Netherlands
| | - T J M Ruers
- The Netherlands Cancer Institute, Department of Surgery, The Netherlands; University of Twente, MIRA Institute, The Netherlands
| |
Collapse
|
44
|
Liu J, Guo W, Tong M. Intraoperative indocyanine green fluorescence guidance for excision of nonpalpable breast cancer. World J Surg Oncol 2016; 14:266. [PMID: 27756411 PMCID: PMC5070155 DOI: 10.1186/s12957-016-1014-2] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2015] [Accepted: 10/03/2016] [Indexed: 01/28/2023] Open
Abstract
Background Different techniques have been used for the guidance of nonpalpable breast cancer (NBC), but none of them has yet achieved perfect results. The aim of this study was to evaluate the feasibility of indocyanine green (ICG) fluorescence-guided nonpalpable breast cancer lesion excision (IFNLE), to introduce an alternative technique. Methods The data about 56 patients with preoperatively diagnosed NBCs operated with the help of intraoperative IFNLE between November of 2010 and September of 2014 were retrospectively analyzed. Results ICG fluorescence localized all lesions at surgery. Re-excision due to positive resection margins was necessary in two patients (3.6 %; 2/56) with ductal carcinoma in situ (DCIS) at the surgical margins. Mastectomy was necessary in one patient (1.8 %; 1/56) due to multifocal invasive carcinoma. The mean volume of the excised tissue was 38.2 ± 16.5 cm3. Conclusions IFNLE is a technically applicable and clinically acceptable procedure whenever a breast cancer needs image-guided excision.
Collapse
Affiliation(s)
- Jintao Liu
- Department of Surgery, The Breast Center, Dalian Central Hospital, Dalian Medical University, No. 826, Xinan Road, Shahekou District, Dalian, 116033, China
| | - Wenbin Guo
- Department of Surgery, The Breast Center, Dalian Central Hospital, Dalian Medical University, No. 826, Xinan Road, Shahekou District, Dalian, 116033, China.
| | - Meng Tong
- Department of Surgery, The Breast Center, Dalian Central Hospital, Dalian Medical University, No. 826, Xinan Road, Shahekou District, Dalian, 116033, China
| |
Collapse
|
45
|
Peek MCL, Ahmed M, Scudder J, Baker R, Pinder SE, Douek M. High intensity focused ultrasound in the treatment of breast fibroadenomata: results of the HIFU-F trial. Int J Hyperthermia 2016; 32:881-888. [DOI: 10.1080/02656736.2016.1212278] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022] Open
Affiliation(s)
- M. C. L. Peek
- Division of Cancer Studies, King’s College London, London, UK
- Guy’s and St Thomas’ NHS Foundation Trust, London, UK
| | - M. Ahmed
- Division of Cancer Studies, King’s College London, London, UK
| | - J. Scudder
- Guy’s and St Thomas’ NHS Foundation Trust, London, UK
| | - R. Baker
- School of Business, University of Salford, Salford, UK
| | - S. E. Pinder
- Division of Cancer Studies, King’s College London, London, UK
- Guy’s and St Thomas’ NHS Foundation Trust, London, UK
| | - M. Douek
- Division of Cancer Studies, King’s College London, London, UK
- Guy’s and St Thomas’ NHS Foundation Trust, London, UK
| | | |
Collapse
|
46
|
Ultrasound-guided breast-conserving surgery for early-stage palpable and nonpalpable invasive breast cancer: decreased excision volume at unchanged tumor-free resection margin. Breast Cancer Res Treat 2016; 158:535-41. [PMID: 27444926 DOI: 10.1007/s10549-016-3914-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2016] [Accepted: 07/14/2016] [Indexed: 01/08/2023]
Abstract
Ultrasound guidance (USG) during breast-conserving surgery improves tumor-free surgical resection margins. The objective of this study was to evaluate whether USG reduces resection volumes without compromising margin status. 134 patients with palpable or nonpalpable T1-2N0-1 invasive breast cancer were treated with USG and compared with a historical reference control group (CON) consisting of palpation-guided (PAG) or wire-guided localization (WIG) breast-conserving surgery. Primary outcomes were excess resection volume and clear margin status, and secondary outcome was re-excision rate. 66 patients underwent USG. In the CON group (n = 68), PAG was performed in 24 (35 %) and WIG in 44 (64 %) patients. Median excision volume [39 (IQR 20-66) vs 56 (38-94) cm(3); p = 0.001] and median calculated resection ratio [1.7 (1.0-2.9) vs 2.8 (1.4-4.6) (p = 0.005)] were significantly smaller in the USG than in the CON group. Median minimal distance to the resection margin [4 mm (IQR 2-5 mm) vs 2 mm (1-4 mm), p = 0.004] was significantly larger. Clear resection margins were achieved in 58 of the USG patients (88 %) and in 58 of the CON patients (86 %) (p = 0.91); this was true in patients with palpable as well as nonpalpable lesions. Reexcision was needed in 6.1 and 7.2 % respectively. Relative risk for re-excision in the USG group was 0.82 (95 % CI 0.23-2.93). In patients with palpable and nonpalpable breast cancers, USG allows for lower excision volume and reduced resection of healthy breast tissue, without increased re-excision rate.
Collapse
|
47
|
Laws A, Brar MS, Bouchard-Fortier A, Leong B, Quan ML. Intraoperative Margin Assessment in Wire-Localized Breast-Conserving Surgery for Invasive Cancer: A Population-Level Comparison of Techniques. Ann Surg Oncol 2016; 23:3290-6. [DOI: 10.1245/s10434-016-5401-2] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2016] [Indexed: 11/18/2022]
|
48
|
Volders JH, Haloua MH, Krekel NMA, Meijer S, van den Tol PM. Current status of ultrasound-guided surgery in the treatment of breast cancer. World J Clin Oncol 2016; 7:44-53. [PMID: 26862490 PMCID: PMC4734937 DOI: 10.5306/wjco.v7.i1.44] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2015] [Revised: 09/02/2015] [Accepted: 10/27/2015] [Indexed: 02/06/2023] Open
Abstract
The primary goal of breast-conserving surgery (BCS) is to obtain tumour-free resection margins. Margins positive or focally positive for tumour cells are associated with a high risk of local recurrence, and in the case of tumour-positive margins, re-excision or even mastectomy are sometimes needed to achieve definite clear margins. Unfortunately, tumour-involved margins and re-excisions after lumpectomy are still reported in up to 40% of patients and additionally, unnecessary large excision volumes are described. A secondary goal of BCS is the cosmetic outcome and one of the main determinants of worse cosmetic outcome is a large excision volume. Up to 30% of unsatisfied cosmetic outcome is reported. Therefore, the search for better surgical techniques to improve margin status, excision volume and consequently, cosmetic outcome has continued. Nowadays, the most commonly used localization methods for BCS of non-palpable breast cancers are wire-guided localization (WGL) and radio-guided localization (RGL). WGL and RGL are invasive procedures that need to be performed pre-operatively with technical and scheduling difficulties. For palpable breast cancer, tumour excision is usually guided by tactile skills of the surgeon performing “blind” surgery. One of the surgical techniques pursuing the aims of radicality and small excision volumes includes intra-operative ultrasound (IOUS). The best evidence available demonstrates benefits of IOUS with a significantly high proportion of negative margins compared with other localization techniques in palpable and non-palpable breast cancer. Additionally, IOUS is non-invasive, easy to learn and can centralize the tumour in the excised specimen with low amount of healthy breast tissue being excised. This could lead to better cosmetic results of BCS. Despite the advantages of IOUS, only a small amount of surgeons are performing this technique. This review aims to highlight the position of ultrasound-guided surgery for malignant breast tumours in the search for better oncological and cosmetic outcomes.
Collapse
|
49
|
|
50
|
Alharbi FM, Chahwan CK, Le Gal SG, Guleryuz KM, Tillou XP, Doerfler AP. Intraoperative ultrasound control of surgical margins during partial nephrectomy. Urol Ann 2016; 8:430-433. [PMID: 28057986 PMCID: PMC5100147 DOI: 10.4103/0974-7796.192107] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
Aims: To evaluate a simple and fast technique to ensure negative surgical margins on partial nephrectomies, while correlating margin statuses with the final pathology report. Subjects and Methods: This study was conducted for patients undergoing partial nephrectomy (PN) with T1–T2 renal tumors from January 2010 to the end of December 2015. Before tumor removal, intraoperative ultrasound (US) localization was performed. After tumor removal and before performing hemostasis of the kidney, the specimens were placed in a saline solution and a US was performed to evaluate if the tumor's capsule were intact, and then compared to the final pathology results. Results: In 177 PN(s) (147 open procedures and 30 laparoscopic procedures) were performed on 147 patients. Arterial clamping was done for 32 patients and the mean warm ischemia time was 19 ± 6 min. The mean US examination time was 41 ± 7 s. The US analysis of surgical margins was negative in 172 cases, positive in four, and in only one case it was not possible to conclude. The final pathology results revealed one false positive surgical margin and one false negative surgical margin, while all other margins were in concert with US results. The mean tumor size was 3.53 ± 1.43 cm, and the mean surgical margin was 2.8 ± 1.5 mm. Conclusions: The intraoperative US control of resection margins in PN is a simple, efficient, and effective method for ensuring negative surgical margins with a small increase in warm ischemia time and can be conducted by the operating urologist.
Collapse
Affiliation(s)
- Feras M Alharbi
- Department of Urology and Transplantation, Caen University Hospital, Caen, France
| | - Charles K Chahwan
- Department of Urology and Transplantation, Caen University Hospital, Caen, France
| | - Sophie G Le Gal
- Department of Urology and Transplantation, Caen University Hospital, Caen, France
| | - Kerem M Guleryuz
- Department of Urology and Transplantation, Caen University Hospital, Caen, France
| | - Xavier P Tillou
- Department of Urology and Transplantation, Caen University Hospital, Caen, France
| | - Arnaud P Doerfler
- Department of Urology and Transplantation, Caen University Hospital, Caen, France
| |
Collapse
|