Ozawa H, Ohki T, Shukuzawa K, Kasa K, Yamada Y, Nakagawa H, Shirouzu M, Omori M, Fukushima S, Tachihara H. Ten-year single-center outcomes following endovascular repair for abdominal aortic aneurysm using the INCRAFT device. J Vasc Surg 2024; 80:405-412. [PMID: 38485069 DOI: 10.1016/j.jvs.2024.03.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2024] [Revised: 03/05/2024] [Accepted: 03/06/2024] [Indexed: 04/11/2024]
Abstract
OBJECTIVE This study aimed to report the long-term outcomes beyond 10 years of endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms using the low-profile INCRAFT device. METHODS This was a single-center, retrospective cohort study of all patients undergoing EVAR using the INCRAFT device as part of the regulatory trial between 2012 and 2013. Primary endpoint was aneurysm-related death. Secondary endpoints were all-cause death, reintervention, late open conversion, and aneurysm status (shrinkage, stable, and growth). RESULTS Thirty patients with a mean age of 71.8 ± 7.7 years were included in this study. The median aneurysm diameter at EVAR was 54.5 mm (interquartile range, 53-56.8 mm). All abdominal aortic aneurysms in this study were treated following the device's instructions for use. At index EVAR, the INCRAFT device was successfully implanted in all patients using a percutaneous approach under local anesthesia. No patients experienced major adverse events or procedure-related complications 30 days after EVAR. During the median follow-up of 125 months (interquartile range, 98-131 months) with follow-up rates of 100% at 5 years and 96.7% at 10 years, aneurysm-related mortality was 0%, and freedom from all-cause mortality was 82.9% at 5 years and 75.3% at 10 years. Reintervention was required in 10 patients with 15 procedures. Sac growth was observed in 11 patients (36.7%), six of whom eventually required late open conversion; five of these patients underwent open aneurysmorrhaphy with stent graft preservation, and one underwent open surgical repair with endograft explantation. Late rupture was identified in one case, where type Ia endoleak led to rupture at 69 months, and open repair was successfully performed. Freedom from reintervention was 89.0% at 5 years but declined to 60.9% at 10 years; freedom from late open conversion was 100% at 5 years but declined to 70.8% at 10 years. CONCLUSIONS Long-term outcomes of the INCRAFT stent graft showed no aneurysm-related deaths. However, sac growth occurred persistently throughout the follow-up period, resulting in a relatively high rate of reinterventions in the later periods, which highlights the importance of lifelong postoperative surveillance and appropriate reinterventions when indicated.
Collapse
Affiliation(s)
- Hirotsugu Ozawa
- Division of Vascular Surgery, Department of Surgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Takao Ohki
- Division of Vascular Surgery, Department of Surgery, The Jikei University School of Medicine, Tokyo, Japan.
| | - Kota Shukuzawa
- Division of Vascular Surgery, Department of Surgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Kentaro Kasa
- Division of Vascular Surgery, Department of Surgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Yuta Yamada
- Division of Vascular Surgery, Department of Surgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Hikaru Nakagawa
- Division of Vascular Surgery, Department of Surgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Miyo Shirouzu
- Division of Vascular Surgery, Department of Surgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Makiko Omori
- Division of Vascular Surgery, Department of Surgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Soichiro Fukushima
- Division of Vascular Surgery, Department of Surgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Hiromasa Tachihara
- Division of Vascular Surgery, Department of Surgery, The Jikei University School of Medicine, Tokyo, Japan
| |
Collapse
|
2
|
Soares RDA, Amaro K, Nasser AI, Cury MVM, Nakamura ET, Pedrosa KDL, Sacilotto R. Endovascular repair for infra-renal aortic aneurysms with supra-renal fixation endoprosthesis: Results and outcomes. Vascular 2024:17085381241264381. [PMID: 39030072 DOI: 10.1177/17085381241264381] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/21/2024]
Abstract
OBJECTIVE The main objective of this paper is to evaluate the outcomes regarding endoleaks, reinterventions, and death related to aneurysm complications in patients submitted to endovascular repair (EVAR) for abdominal aortoiliac aneurysm (AAA) using Endurant II (Medtronic) and Zenith Flex (Cook) endografts. METHODS This was a prospective, consecutive cohort study of patients with AAA who underwent EVAR with the use of Endurant II stent graft and Zenith Flex endograft. RESULTS A total of 156 patients submitted to EVAR were evaluated. The perioperative mortality was 5.1%, 8 patients. The median clinical follow-up period was 760 ± 80 days. There were 28 patients (17.9%) submitted to urgent repair of the aneurysm (symptomatic expansion or rupture) and 128 patients (82.1%) submitted to elective repair. There were 36 cases (23.1%) of later endoleak and most of them are Type II endoleaks (21 patients, 13.4%). There were 12 cases of Type I endoleak. Moreover, regarding limb graft occlusion (LGO), there were 9 patients (5.8%). The overall survival rate in Kaplan-Meier analysis at 720 days was 84.8% in the total cohort. The freedom from reintervention rate in Kaplan-Meier analysis at 720 days was 92.7% in the total cohort. The linear regression analysis for survival rates showed that chronic kidney disease (p = .03; hazard ratio (HR) = 2.82, CI = 1.07-4.44) was the only factor related to poorer survival rates in both univariate and multivariate analyses. The linear regression analysis showed that the presence of endoleaks (p < .001, HR = 6.69, CI = 2.26-8.48) and limb graft occlusion (p < .001, HR = 8.02, CI = 1.60-9.99) were related to reintervention in both univariate and multivariate analyses. CONCLUSION In this present study, supra-renal fixation endograft devices were safe and efficient in treating AAA, with satisfactory results and no renal compromise. The linear regression analysis showed that the presence of endoleaks and limb graft occlusion were related to higher reintervention rates in both univariate and multivariate analyses.
Collapse
Affiliation(s)
- Rafael de Athayde Soares
- Division of Vascular and Endovascular Surgery, Hospital Do Servidor Público Estadual de São Paulo, Sao Paulo, Brazil
| | - Kaline Amaro
- Division of Vascular and Endovascular Surgery, Hospital Do Servidor Público Estadual de São Paulo, Sao Paulo, Brazil
| | - Ana Isabel Nasser
- Division of Vascular and Endovascular Surgery, Hospital Do Servidor Público Estadual de São Paulo, Sao Paulo, Brazil
| | - Marcus Vinícius Martins Cury
- Division of Vascular and Endovascular Surgery, Hospital Do Servidor Público Estadual de São Paulo, Sao Paulo, Brazil
| | - Edson Takamitsu Nakamura
- Division of Vascular and Endovascular Surgery, Hospital Do Servidor Público Estadual de São Paulo, Sao Paulo, Brazil
| | - Keityane de Lima Pedrosa
- Division of Vascular and Endovascular Surgery, Hospital Do Servidor Público Estadual de São Paulo, Sao Paulo, Brazil
| | - Roberto Sacilotto
- Division of Vascular and Endovascular Surgery, Hospital Do Servidor Público Estadual de São Paulo, Sao Paulo, Brazil
| |
Collapse
|
3
|
Smorenburg SPM, de Bruin JL, Zeebregts CJ, Reijnen MMPJ, Verhagen HJM, Heyligers JMM. Long Term Outcomes of the Gore Excluder Low Permeability Endoprosthesis for the Treatment of Infrarenal Aortic Aneurysms. Eur J Vasc Endovasc Surg 2024; 68:18-27. [PMID: 38527519 DOI: 10.1016/j.ejvs.2024.03.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 02/23/2024] [Accepted: 03/21/2024] [Indexed: 03/27/2024]
Abstract
OBJECTIVE This study evaluated the long term outcomes of endovascular aneurysm repair using the Gore Excluder Low Permeability (LP) endoprosthesis across high volume Dutch hospitals. METHODS A retrospective analysis was conducted of patients treated with the Excluder LP for infrarenal abdominal aortic aneurysm (AAA) in four hospitals between 2004 and 2017. Primary outcomes were overall survival, freedom from re-interventions (overall, inside and outside instructions for use, IFU), and AAA sac dynamics: growth (> 5 mm), stabilisation, and regression (< 5 mm). Secondary outcomes were technical success (device deployment), procedural parameters, and re-interventions. Follow up visits were extracted from patient files, with imaging assessed for complications and AAA diameter. RESULTS Five hundred and fourteen patients were enrolled, with a median (IQR) follow up of 5.0 (2.9, 6.9) years. Survival rates were 94.0% at one year, 73.0% at five years, and 37.0% at 10 years, with freedom from re-interventions of 89.0%, 79.0%, and 71.0%, respectively. 37.9% were treated outside IFU, leading to significantly more re-interventions over 10 years compared with those treated inside IFU (36.0% vs. 25.0%, respectively; p = .044). The aneurysm sac regressed by 53.5% at one year, 65.8% at five years, and 77.8% at 10 years, and grew by 9.8%, 14.3%, and 22.2%, respectively. Patients with one year sac growth had significantly worse survival (p = .047). Seven patients (1.4%) had a ruptured aneurysm during follow up. Over 15 years, type 1a endoleak occurred in 5.3%, type 1b in 3.1%, type 3 in 1.9%, type 4 in 0.2%, and type 2 in 35.6% of patients. CONCLUSION This multicentre study of real world endovascular aneurysm repair data using the Gore Excluder LP endoprosthesis demonstrated robust long term survival and re-intervention rates, despite 37.9% of patients being treated outside IFU, with type 4 endoleak being rare. Treatment outside IFU significantly increased re-intervention rates and one year sac growth was associated with statistically significantly worse survival.
Collapse
Affiliation(s)
- Stefan P M Smorenburg
- Department of Surgery, Amsterdam University Medical Centres location Vrije Universiteit, Amsterdam, the Netherlands
| | - Jorg L de Bruin
- Department of Vascular Surgery, Erasmus Medical Centre, Rotterdam, the Netherlands
| | - Clark J Zeebregts
- Department of Surgery (Division of Vascular Surgery), University Medical Centre Groningen, University of Groningen, Groningen, the Netherlands
| | - Michel M P J Reijnen
- Department of Surgery, Rijnstate, Arnhem, the Netherlands; Multi-Modality Medical Imaging Group, University of Twente, Enschede, the Netherlands
| | - Hence J M Verhagen
- Department of Vascular Surgery, Erasmus Medical Centre, Rotterdam, the Netherlands
| | - Jan M M Heyligers
- Department of Surgery, Elisabeth-Tweesteden Hospital, Tilburg, the Netherlands.
| |
Collapse
|
4
|
Long C, Katsargyris A, Milner R, Verhoeven E. Five-Year Results for Abdominal Aortic Aneurysm Repair with the GORE® EXCLUDER® Device: Insights from the Gore Global Registry for Endovascular Aortic Treatment (GREAT). Ann Vasc Surg 2024; 106:247-254. [PMID: 38815908 DOI: 10.1016/j.avsg.2024.03.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Revised: 03/10/2024] [Accepted: 03/11/2024] [Indexed: 06/01/2024]
Abstract
BACKGROUND The early postoperative benefits of endovascular aneurysm repair (EVAR) have been well established but questions remain regarding its durability at mid-term and long-term time points. Long-term results in real-world use of EVAR outside of randomized trial data are limited. This study used the Global Registry for Endovascular Aortic Treatment registry to explore the 5-year outcomes with the GORE EXCLUDER device in real-world clinical circumstances. METHODS All patients within the Global Registry for Endovascular Aortic Treatment registry who underwent an infrarenal abdominal aortic aneurysm repair with the GORE EXCLUDER device were included in this study. Baseline characteristics and demographic information of the cohort were collected. End points included mortality (all-cause and aneurysm-related), serious endoleaks, aneurysm sac diameter, endograft integrity (fracture, compression, migration), post-EVAR aortic rupture, device-related reintervention, conversion to open repair, graft explantation, and major adverse cardiovascular events. RESULTS A total of 3,216 patients were included in this analysis. The cohort reflected a significantly comorbid population with 46% of patients reaching a Charlson Comorbidity Index score of ≥5. Follow-up at 5 years was 60% of eligible participants. The freedom from aortic-related mortality was at 98.8% and overall survival was 71.2%. Postoperative major adverse cardiovascular events occurred in 49 (1.5%) patients. Device-related intervention through 5 years was 7.2% and the overall serious endoleak rate was 6.8%. Less than 1% of patients required an open conversion/revision and aortic rupture following device placement occurred in 15 (0.5%) patients. Aneurysm sac regression was achieved in 58.1% of patients at 5 years, and stability/absence of growth was observed in 83.6% at 5 years. CONCLUSIONS This study supports the durability of the GORE EXCLUDER device through 5 years with negligible incidence of graft integrity compromise and low aortic/device-related reintervention rates. Furthermore, the efficacy of the device is highlighted with low aortic-related mortality and high sac regression/stability diameter through 5 years.
Collapse
Affiliation(s)
- Chandler Long
- Division of Vascular and Endovascular Surgery, Duke University Medical Center, Durham, NC.
| | - Athanasios Katsargyris
- Division of Vascular and Endovascular Surgery, General Hospital & Paracelsus Medical University Nuremberg, Nuremberg, Germany
| | - Ross Milner
- Division of Vascular Surgery, University of Chicago Medical Center, Chicago, IL
| | - Eric Verhoeven
- Division of Vascular and Endovascular Surgery, General Hospital & Paracelsus Medical University Nuremberg, Nuremberg, Germany
| |
Collapse
|
5
|
Holden A, Hill AA, Khashram M, Heyligers JMM, Wiersema AM, Hayes PD, Reijnen MMPJ. One-year follow-up after active aortic aneurysm sac treatment with shape memory polymer devices during endovascular aneurysm repair. J Vasc Surg 2024; 79:1090-1100.e4. [PMID: 38185214 DOI: 10.1016/j.jvs.2023.12.045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2023] [Revised: 12/28/2023] [Accepted: 12/30/2023] [Indexed: 01/09/2024]
Abstract
OBJECTIVE To determine the safety and efficacy of treating abdominal aortic aneurysm (AAA) sacs with polyurethane shape memory polymer (SMP) devices during endovascular aneurysm repair (EVAR), using a technique to fully treat the target lumen after endograft placement (aortic flow volume minus the endograft volume). SMP devices self-expand in the sac to form a porous scaffold that supports thrombosis throughout its structure. METHODS Two identical prospective, multicenter, single-arm studies were conducted in New Zealand and the Netherlands. The study population was adult candidates for elective EVAR of an infrarenal AAA (diameter of ≥55 mm in men and ≥50 mm in women). Key exclusion criteria were an inability to adequately seal a common iliac artery aneurysm, patent sac feeding vessels of >4 mm, and a target lumen volume of <20 mL or >135 mL. Target lumen volumes were estimated by subtracting endograft volumes from preprocedural imaging-based flow lumen volumes. SMP devices were delivered immediately after endograft deployment via a 6F sheath jailed in a bowed position in the sac. The primary efficacy end point was technical success, defined as filling the actual target lumen volume with fully expanded SMP at the completion of the procedure. Secondary efficacy outcome measures during follow-up were the change in sac volume and diameter, rate of type II endoleak and type I or III endoleaks, and the rate of open repair and related reinterventions, with data collection at 30 days, 6 months, and 1 year (to date). Baseline sac volumes and diameters for change in sac size analyses were determined from 30-day imaging studies. Baseline and follow-up volumes were normalized by subtraction of the endograft volume. RESULTS Of 34 patients treated with SMP devices and followed per protocol, 33 patients were evaluable at 1 year. Preprocedural aneurysm volume was 181.4 mL (95% confidence interval [CI], 150.7-212.1 mL) and preprocedural aneurysm diameter was 60.8 mm (95% CI, 57.8-63.9 mm). The target lumen volume was 56.3 mL (95% CI, 46.9-65.8 mL). Technical success was 100% and the ratio of SMP fully expanded volume to estimated target lumen volume was 1.4 ± 0.3. Baseline normalized sac volume and diameter were 140.7 mL (95% CI, 126.6-154.9 mL) and 61.0 mm (95% CI, 59.7-62.3 mm). The adjusted mean percentage change in normalized volume at 1 year was -28.8% (95% CI, -35.3 to -22.3%; P < .001). The adjusted mean change in sac diameter at 1 year was -5.9 mm (95% CI, -7.5 to -4.4 mm; P < .001). At 1 year, 81.8% of patients (95% CI, 64.5%-93.0%) achieved a ≥10% decrease in normalized volume and 57.6% of patients (95% CI, 39.2%-74.5%) achieved a ≥5 mm decrease in diameter. No device- or study procedure-related major adverse events occurred through 1 year after the procedure. CONCLUSIONS Treatment of AAA sacs with SMP devices during EVAR resulted in significant sac volume and diameter regression at 1 year with an acceptable safety profile in this prospective study.
Collapse
Affiliation(s)
- Andrew Holden
- Department of Interventional Radiology, Auckland City Hospital, Auckland, New Zealand.
| | - Andrew A Hill
- Vascular Services, Auckland City Hospital, Auckland, New Zealand
| | - Manar Khashram
- Department of Vascular & Endovascular Surgery, Waikato Hospital, Hamilton, New Zealand
| | - Jan M M Heyligers
- Department of Surgery, Elisabeth-TweeSteden Ziekenhuis, Tilburg, The Netherlands
| | - Arno M Wiersema
- Department of Surgery, Dijklander Ziekenhuis, Hoorn, The Netherlands
| | | | - Michel M P J Reijnen
- Department of Surgery, Rijnstate, Arnhem, The Netherlands; Multi-Modality Medical Imaging Group, University of Twente, Enschede, The Netherlands
| |
Collapse
|
6
|
Vos CG, Fouad F, Dieleman IM, Schuurmann RC, de Vries JPP. Importance of sac regression after EVAR and the role of EndoAnchors. THE JOURNAL OF CARDIOVASCULAR SURGERY 2024; 65:99-105. [PMID: 38551514 DOI: 10.23736/s0021-9509.24.12992-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2024]
Abstract
The initial success and widespread adoption of endovascular aneurysm repair (EVAR) for the treatment of abdominal aortic aneurysms have been tempered by numerous reports of secondary interventions and increased long-term mortality compared with open repair. Over the past decade, several studies on postoperative sac dynamics after EVAR have suggested that the presence of sac regression is a benign feature with a favorable prognosis. Conversely, increasing sacs and even stable sacs can be indicators of more unstable sac behavior with worse outcomes in the long-term. Endoleaks were initially perceived as the main drivers of sac behavior. However, the observation that sac regression can occur in the presence of endoleaks, and vice versa - increasing sacs without evidence of endoleak - on imaging studies, suggests the involvement of other contributing factors. These factors can be divided into anatomical factors, patient characteristics, sac thrombus composition, and device-related factors. The shift of interest away from especially type 2 endoleaks is further supported by promising results with the use of EndoAnchors regarding postoperative sac behavior. This review provides an overview of the existing literature on the implications and known risk factors of post-EVAR sac behavior, describes the accurate measurement of sac behavior, and discusses the use of EndoAnchors to promote sac regression.
Collapse
Affiliation(s)
- Cornelis G Vos
- Department of Surgery, Martini Hospital, Groningen, the Netherlands
| | - Fatima Fouad
- Division of Vascular Surgery, Department of Surgery, University Medical Center Groningen, Groningen, the Netherlands -
| | - Isabel M Dieleman
- Division of Vascular Surgery, Department of Surgery, University Medical Center Groningen, Groningen, the Netherlands
| | - Richte Cl Schuurmann
- Division of Vascular Surgery, Department of Surgery, University Medical Center Groningen, Groningen, the Netherlands
| | - Jean-Paul Pm de Vries
- Division of Vascular Surgery, Department of Surgery, University Medical Center Groningen, Groningen, the Netherlands
| |
Collapse
|
7
|
Gentsu T, Yamaguchi M, Sasaki K, Kawasaki R, Horinouchi H, Fukuda T, Miyamoto N, Mori T, Sakamoto N, Uotani K, Taniguchi T, Koda Y, Yamanaka K, Takahashi H, Okada K, Hayashi T, Watanabe T, Nomura Y, Matsushiro K, Ueshima E, Okada T, Sugimoto K, Murakami T. Side branch embolization before endovascular abdominal aortic aneurysm repair to prevent type II endoleak: A prospective multicenter study. Diagn Interv Imaging 2024:S2211-5684(24)00079-2. [PMID: 38503637 DOI: 10.1016/j.diii.2024.03.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Revised: 02/28/2024] [Accepted: 03/05/2024] [Indexed: 03/21/2024]
Abstract
PURPOSE The purpose of the study was to evaluate the efficacy and safety of pre-emptive transcatheter arterial embolization (P-TAE) of aortic side branches to prevent type II endoleak in patients with abdominal aortic aneurysm after endovascular abdominal aneurysm repair (EVAR). MATERIALS AND METHODS This multicenter, prospective, single-arm trial enrolled 100 patients with abdominal aortic aneurysm from nine hospitals between 2018 and 2021. There were 85 men and 15 women, with a mean age of 79.6 ± 6.0 (standard deviation) years (range: 65-97 years). P-TAE was attempted for patent aortic side branches, including the inferior mesenteric artery, lumbar arteries, and other branches. The primary endpoint was late type II endoleak incidence at 6 months post-repair. Secondary endpoints included changes in aneurysmal sac diameter at 6- and 12 months, complications, re-intervention, and aneurysm-related mortality. Aneurysm sac changes at 6- and 12 months was compared between the late and no-late type II endoleak groups. RESULTS Coil embolization was successful in 80.9% (321/397) of patent aortic side branches, including 86.3% of the inferior mesenteric arteries, 80.3% of lumbar arteries, and 55.6% of other branches without severe adverse events. Late type II endoleak incidence at 6 months was 8.9% (8/90; 95% confidence interval: 3.9-16.8%). Aneurysm sac shrinkage > 5 mm was observed in 41.1% (37/90) and 55.3% (47/85) of the patients at 6- and 12-months post-EVAR, respectively. Patients with late type II endoleak had less aneurysm sac shrinkage than those without type II endoleak at 12 months (-0.2 mm vs. -6.0 mm; P = 0.040). No patients required re-intervention for type II endoleak, and no aneurysm-related mortalities occurred. CONCLUSION P-TAE is safe and effective in preventing type II endoleak, leading to early sac shrinkage at 12 months following EVAR.
Collapse
Affiliation(s)
- Tomoyuki Gentsu
- Department of Diagnostic and Interventional Radiology, Kobe University Hospital, Kobe, 7-5-2 Kusunokicho, Chuo Ward, Kobe City, Hyogo 650-0017, Japan
| | - Masato Yamaguchi
- Department of Diagnostic and Interventional Radiology, Kobe University Hospital, Kobe, 7-5-2 Kusunokicho, Chuo Ward, Kobe City, Hyogo 650-0017, Japan.
| | - Koji Sasaki
- Department of Diagnostic and Interventional Radiology, Kobe University Hospital, Kobe, 7-5-2 Kusunokicho, Chuo Ward, Kobe City, Hyogo 650-0017, Japan
| | - Ryota Kawasaki
- Department of Diagnostic and Interventional Radiology, Hyogo Prefectural Harima-Himeji General Medical Center, Himeji, Hyogo 670-8560, Japan
| | - Hiroki Horinouchi
- Department of Radiology, National Cerebral and Cardiovascular Center, Suita, Osaka 565-8565, Japan
| | - Tetsuya Fukuda
- Department of Radiology, National Cerebral and Cardiovascular Center, Suita, Osaka 565-8565, Japan
| | - Naokazu Miyamoto
- Department of Radiology, Kita-harima Medical Center, Ono, Hyogo 675-1323, Japan
| | - Takeki Mori
- Department of Radiology, Japanese Red Cross Kobe Hospital, Kobe, Hyogo 651-0073, Japan
| | - Noriaki Sakamoto
- Department of Diagnostic and Interventional Radiology, Kakogawa Central City Hospital, Kakogawa, Hyogo 675-8520, Japan
| | - Kensuke Uotani
- Department of Radiology, Hyogo Prefectural Awaji Medical Center, Sumoto, Hyogo 656-0021, Japan
| | | | - Yojiro Koda
- Division of Cardiovascular Surgery, Department of Surgery, Kobe University Hospital, Kobe, Hyogo 650-0017, Japan
| | - Katsuhiro Yamanaka
- Division of Cardiovascular Surgery, Department of Surgery, Kobe University Hospital, Kobe, Hyogo 650-0017, Japan
| | - Hiroaki Takahashi
- Division of Cardiovascular Surgery, Department of Surgery, Kobe University Hospital, Kobe, Hyogo 650-0017, Japan
| | - Kenji Okada
- Division of Cardiovascular Surgery, Department of Surgery, Kobe University Hospital, Kobe, Hyogo 650-0017, Japan
| | - Taro Hayashi
- Department of Cardiovascular Surgery, Akashi Medical Center, Akashi, Hyogo 673-0896, Japan
| | - Toshitaka Watanabe
- Department of Cardiovascular Surgery, Akashi Medical Center, Akashi, Hyogo 673-0896, Japan
| | - Yoshikatsu Nomura
- Department of Cardiovascular Surgery, Hyogo Prefectural Harima-Himeji General Medical Center, Himeji, Hyogo 670-8560, Japan
| | - Keigo Matsushiro
- Department of Diagnostic and Interventional Radiology, Kobe University Hospital, Kobe, 7-5-2 Kusunokicho, Chuo Ward, Kobe City, Hyogo 650-0017, Japan
| | - Eisuke Ueshima
- Department of Diagnostic and Interventional Radiology, Kobe University Hospital, Kobe, 7-5-2 Kusunokicho, Chuo Ward, Kobe City, Hyogo 650-0017, Japan
| | - Takuya Okada
- Department of Diagnostic and Interventional Radiology, Kobe University Hospital, Kobe, 7-5-2 Kusunokicho, Chuo Ward, Kobe City, Hyogo 650-0017, Japan
| | - Koji Sugimoto
- Department of Diagnostic and Interventional Radiology, Kobe University Hospital, Kobe, 7-5-2 Kusunokicho, Chuo Ward, Kobe City, Hyogo 650-0017, Japan
| | - Takamichi Murakami
- Department of Diagnostic and Interventional Radiology, Kobe University Hospital, Kobe, 7-5-2 Kusunokicho, Chuo Ward, Kobe City, Hyogo 650-0017, Japan
| |
Collapse
|
8
|
Vakhitov D, Grandhomme J, Kuntz S, Christ L, Neumann N, Heim F, Chakfé N, Lejay A. Editor's Choice -- Type IIIb Endoleaks: Fabric Perforations of Explanted New Generation Endoprostheses. Eur J Vasc Endovasc Surg 2024; 67:446-453. [PMID: 37717814 DOI: 10.1016/j.ejvs.2023.09.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Revised: 08/20/2023] [Accepted: 09/11/2023] [Indexed: 09/19/2023]
Abstract
OBJECTIVE To analyse explanted endografts (EGs) and describe fabric degradation responsible for type IIIb endoleaks. METHODS As part of the European collaborative retrieval programme, 32 EGs with fabric defects on macroscopic evaluation were selected. The explanted EGs were processed and studied based on the ISO 9001 certified standard protocol. It includes instructions on the collection, transportation, cleaning, and examination of explanted material. The precise analysis was performed with a digital microscope of 20 - 200 times magnification. Possible perforation mechanisms were assessed in stress tests. RESULTS The median time to explantation of the 32 EGs was 54 months. The explants included 65 separate EG modules, with 46 (70.8%) having a combined 388 fabric perforations. Each EG had a median of 4.79 mm2 (interquartile range [IQR] 9.86 mm2) of cumulated hole area (an average of 0.13% of an EG's area). There were 239 (61.6%) expanded polytetrafluoroethylene (ePTFE; 11 EGs) and 149 (38.4%) polyethylene terephthalate (PET; 21 EGs) fabric ruptures, with no difference in hole distribution between these types of material. Overall, 126 (32.5%) stent related and 262 (67.5%) non-stent related fabric perforations were identified. Perforations caused by fabric fatigue in ePTFE (151, 63.2%) and material kinking in PET (41, 27.5%) were the most common. The stent related perforations were larger in size (0.80 mm2) than non-stent related perforations (0.19 mm2); p < .001. Wider interstent spaces and prolonged implantation duration were associated with an increased risk of stent related perforation development; p < .001 and p = .004, respectively. Large stent related perforations were also detected in the short term, suggesting mechanical issues as underlying causes. CONCLUSION The fabric of EGs may degrade and lead to the development of perforations. The largest perforations are stent related. Their occurrence and size depend on the implantation time and the EG shape affected by arterial tortuosity. The conclusions are limited to the samples from a select explant group.
Collapse
Affiliation(s)
| | - Jonathan Grandhomme
- GEPROMED, Strasbourg, France; Department of Vascular Surgery and Kidney Transplantation, University Hospital of Strasbourg, Strasbourg, France
| | - Salomé Kuntz
- GEPROMED, Strasbourg, France; Department of Vascular Surgery and Kidney Transplantation, University Hospital of Strasbourg, Strasbourg, France
| | | | | | - Frédéric Heim
- GEPROMED, Strasbourg, France; Laboratoire de Physique et Mécanique Textile, Université de Haute-Alsace, Mulhouse, France
| | - Nabil Chakfé
- GEPROMED, Strasbourg, France; Department of Vascular Surgery and Kidney Transplantation, University Hospital of Strasbourg, Strasbourg, France
| | - Anne Lejay
- GEPROMED, Strasbourg, France; Department of Vascular Surgery and Kidney Transplantation, University Hospital of Strasbourg, Strasbourg, France
| |
Collapse
|
9
|
Wanhainen A, Van Herzeele I, Bastos Goncalves F, Bellmunt Montoya S, Berard X, Boyle JR, D'Oria M, Prendes CF, Karkos CD, Kazimierczak A, Koelemay MJW, Kölbel T, Mani K, Melissano G, Powell JT, Trimarchi S, Tsilimparis N, Antoniou GA, Björck M, Coscas R, Dias NV, Kolh P, Lepidi S, Mees BME, Resch TA, Ricco JB, Tulamo R, Twine CP, Branzan D, Cheng SWK, Dalman RL, Dick F, Golledge J, Haulon S, van Herwaarden JA, Ilic NS, Jawien A, Mastracci TM, Oderich GS, Verzini F, Yeung KK. Editor's Choice -- European Society for Vascular Surgery (ESVS) 2024 Clinical Practice Guidelines on the Management of Abdominal Aorto-Iliac Artery Aneurysms. Eur J Vasc Endovasc Surg 2024; 67:192-331. [PMID: 38307694 DOI: 10.1016/j.ejvs.2023.11.002] [Citation(s) in RCA: 49] [Impact Index Per Article: 49.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Accepted: 09/20/2023] [Indexed: 02/04/2024]
Abstract
OBJECTIVE The European Society for Vascular Surgery (ESVS) has developed clinical practice guidelines for the care of patients with aneurysms of the abdominal aorta and iliac arteries in succession to the 2011 and 2019 versions, with the aim of assisting physicians and patients in selecting the best management strategy. METHODS The guideline is based on scientific evidence completed with expert opinion on the matter. By summarising and evaluating the best available evidence, recommendations for the evaluation and treatment of patients have been formulated. The recommendations are graded according to a modified European Society of Cardiology grading system, where the strength (class) of each recommendation is graded from I to III and the letters A to C mark the level of evidence. RESULTS A total of 160 recommendations have been issued on the following topics: Service standards, including surgical volume and training; Epidemiology, diagnosis, and screening; Management of patients with small abdominal aortic aneurysm (AAA), including surveillance, cardiovascular risk reduction, and indication for repair; Elective AAA repair, including operative risk assessment, open and endovascular repair, and early complications; Ruptured and symptomatic AAA, including peri-operative management, such as permissive hypotension and use of aortic occlusion balloon, open and endovascular repair, and early complications, such as abdominal compartment syndrome and colonic ischaemia; Long term outcome and follow up after AAA repair, including graft infection, endoleaks and follow up routines; Management of complex AAA, including open and endovascular repair; Management of iliac artery aneurysm, including indication for repair and open and endovascular repair; and Miscellaneous aortic problems, including mycotic, inflammatory, and saccular aortic aneurysm. In addition, Shared decision making is being addressed, with supporting information for patients, and Unresolved issues are discussed. CONCLUSION The ESVS Clinical Practice Guidelines provide the most comprehensive, up to date, and unbiased advice to clinicians and patients on the management of abdominal aorto-iliac artery aneurysms.
Collapse
|
10
|
Simmering JA, de Vries M, Haalboom M, Reijnen MMPJ, Slump CH, Geelkerken RH. Geometrical Changes of the Aorta as Predictors for Thromboembolic Events After EVAR With the Anaconda Stent-Graft. J Endovasc Ther 2023; 30:904-919. [PMID: 35786215 PMCID: PMC10637097 DOI: 10.1177/15266028221105839] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE Thromboembolic events (TE), including limb graft occlusion (LGO) and distal limb embolization (DLE), are common complications after endovascular aneurysm repair (EVAR). The aim of this study was to find predictors for TE in patients treated with the Anaconda stent-graft for infrarenal aneurysms. MATERIALS AND METHODS Geometrical and anatomical variables were retrospectively analyzed in a consecutive Anaconda cohort. Pre- and postoperative CT scans were used to derive geometrical parameters length, curvature, torsion, and tortuosity index (TI) from the center lumen lines (CLLs). Limb characteristics, pre-to-post EVAR and mid-term-follow-up changes in the parameters were evaluated for their predictive value for TE. RESULTS Eighty-four patients (mean age 74±8.3 years, 74 men) were enrolled. The risk of TE was lowered with pre-to-post implant decreasing TI (steps of 0.05: OR: 1.30, 95% CI: 1.01-1.66, p=0.04), pre-to-post implant decreasing mean curvature (OR: 1.08, 95% CI: 1.01-1.16, p=0.03), and a larger degree of circumferential common iliac artery (CIA) calcification (OR: 0.98, 95% CI: 0.97-1.00, p=0.03). The only LGO predictor was the caudal relocation of maximal curvature after EVAR (OR: 1.01, 95% CI: 1.00-1.01, p=0.04). Preventors of DLE were CIA diameter (OR: 0.87, 95% CI: 0.76-0.99, p=0.04), circumferential CIA calcification (OR: 0.97, 95% CI: 0.95-1.00, p=0.03), mean and maximal curvature of the preoperative aortoiliac trajectory (OR: 0.86, 95% CI: 0.79-0.94, p<0.01 and OR: 0.97, 95% CI: 0.95-1.00, p=0.03, respectively) and pre-to-postoperative decrease in mean curvature (OR: 1.11, 95% CI: 1.02-1.21, p=0.02). Midterm TE predictors were length (OR: 0.95, 95% CI: 0.89-1.01, p=0.08) and torsion maximum location (OR: 1.01, 95% CI: 0.99-1.01, p=0.10). CONCLUSION The present study confirms that treatment of infrarenal AAA with an Anaconda stent-graft is related to a relatively high TE rate which decreases with a pre-to-postoperative reduction in curvature and TI, and a larger degree of circumferential CIA calcification. In other words, more aortoiliac straightening and more circumferential CIA calcification may prevent TE development after EVAR with this stent-graft.
Collapse
Affiliation(s)
- Jaimy A. Simmering
- Division of Vascular Surgery, Department of Surgery, Medisch Spectrum Twente, Enschede, The Netherlands
- Multi-Modality Medical Imaging (M3i) Group, Faculty of Science and Technology, Technical Medical Centre, University of Twente, Enschede, The Netherlands
| | - Mattijs de Vries
- Division of Vascular Surgery, Department of Surgery, Diakonessenhuis Utrecht, Utrecht, The Netherlands
| | - Marieke Haalboom
- Medical School Twente, Medisch Spectrum Twente, Enschede, The Netherlands
| | - Michel M. P. J. Reijnen
- Multi-Modality Medical Imaging (M3i) Group, Faculty of Science and Technology, Technical Medical Centre, University of Twente, Enschede, The Netherlands
- Division of Vascular Surgery, Department of Surgery, Rijnstate Hospital, Arnhem, The Netherlands
| | - Cornelis H. Slump
- Robotics and Mechatronics (RaM) Group, Faculty of Electrical Engineering, Mathematics and Computer Science, Technical Medical Centre, University of Twente, Enschede, The Netherlands
| | - Robert H. Geelkerken
- Division of Vascular Surgery, Department of Surgery, Medisch Spectrum Twente, Enschede, The Netherlands
- Multi-Modality Medical Imaging (M3i) Group, Faculty of Science and Technology, Technical Medical Centre, University of Twente, Enschede, The Netherlands
| |
Collapse
|
11
|
Tatsuishi W, Shibuya K, Konishi Y, Oi A, Soda T, Abe T. Endovascular Aneurysm Repair Using Physician-Modified Fenestrated Endurant Contralateral Limb for Internal Iliac Artery Preservation. J Endovasc Ther 2023:15266028231215204. [PMID: 38041256 DOI: 10.1177/15266028231215204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2023]
Abstract
CLINICAL IMPACT We developed a novel Endovascular aortic repair technique for internal iliac artery preservation using a physician modified Endurant contralateral limb. This procedure was safe and reliable for preserving internal iliac artery flow in 24 patients with common and internal iliac artery aneurysms. We believe that our technique has the potential to expand the anatomic indications for internal iliac artery preserving procedures.
Collapse
Affiliation(s)
- Wataru Tatsuishi
- Division of Cardiovascular Surgery, Department of General Surgical Science, Gunma University, Maebashi, Japan
| | - Kei Shibuya
- Department of Radiology, Gunma University, Maebashi, Japan
| | - Yasunobu Konishi
- Division of Cardiovascular Surgery, Department of General Surgical Science, Gunma University, Maebashi, Japan
| | - Atsushi Oi
- Division of Cardiovascular Surgery, Department of General Surgical Science, Gunma University, Maebashi, Japan
| | - Takashi Soda
- Division of Cardiovascular Surgery, Department of General Surgical Science, Gunma University, Maebashi, Japan
| | - Tomonobu Abe
- Division of Cardiovascular Surgery, Department of General Surgical Science, Gunma University, Maebashi, Japan
| |
Collapse
|
12
|
Arko FR, Pearce BJ, Henretta JP, Fugate MW, Torsello G, Panneton JM, Peng Y, Edward Garrett H. Five-year outcomes of endosuture aneurysm repair in patients with short neck abdominal aortic aneurysm from the ANCHOR registry. J Vasc Surg 2023; 78:1418-1425.e1. [PMID: 37558144 DOI: 10.1016/j.jvs.2023.07.058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 07/24/2023] [Accepted: 07/29/2023] [Indexed: 08/11/2023]
Abstract
OBJECTIVE Hostile aortic neck anatomies such as proximal short necks are known to put patients at an increased risk for type IA endoleaks, migration, and need for reinterventions. The Heli-FX EndoAnchor System was designed to improve seal of aortic stent grafts. Endosuture aneurysm repair (ESAR) using EndoAnchors with the Endurant stent graft has been shown to be safe and effective for the treatment of patients with short necks through one year. This study reports the 5-year patient outcomes of the Aneurysm Treatment using the Heli-FX EndoAnchor System Global Registry (ANCHOR) short neck regulatory cohort. METHODS The 70 patients from the ANCHOR Registry were cohort submitted to regulators for approval of the Endurant short neck indication. Patients had an infrarenal neck length of ≥ 4 mm and <10 mm. At 5 years, this short neck cohort had clinical and imaging follow-up compliance rates of 85% (28/33) and 70% (23/33), respectively. RESULTS The short neck cohort had a mean age of 71.3±8.1 years and was 27.1% (19/70) female. Kaplan Meier freedom from all-cause mortality was 68.5 ± 6.2%, freedom from aneurysm-related mortality was 90.1 ± 4.5%, freedom from any endovascular or surgical secondary procedure was 76.9 ± 7.2%, and freedom from rupture was 95.6 ± 3.2%. Eight patients had a total of nine type IA endoleaks detected through 5 years, of which three resolved spontaneously by the next follow-up visit. There were two patients with renal complications who did not undergo reintervention and there were no device migrations reported through 5 years. After 5 years, 68.2% of patients (15/22) had sac regression, 13.6% (3/22) had stable sacs, and 18.2% (4/22) had increased sac diameter as compared with their 1-month measurements. CONCLUSIONS After ESAR treatment using Heli-FX EndoAnchors with Endurant, the 5-year outcomes of the short neck cohort from the ANCHOR registry had encouraging results with regards to proximal neck-related complications, secondary procedures, and sac regression. This review of ESAR in patients with short proximal necks showed positive outcomes through 5 years although follow-up of a larger cohort is necessary.
Collapse
Affiliation(s)
- Frank R Arko
- Division of Vascular and Endovascular Surgery, Carolinas Medical Center, Charlotte, NC.
| | - Benjamin J Pearce
- Division of Vascular and Endovascular Surgery, University of Alabama at Birmingham, Birmingham, AL
| | - John P Henretta
- Division of Vascular and Endovascular Surgery, Mission Hospital, Asheville, NC
| | - Mark W Fugate
- Division of Vascular and Endovascular Surgery, Chattanooga Heart Institute Memorial Hospital, Chattanooga, TN
| | - Giovanni Torsello
- Division of Vascular and Endovascular Surgery, St. Franziskus-Hospital, Münster, Germany
| | - Jean M Panneton
- Division of Vascular and Endovascular Surgery, Eastern Virginia Medical School, Norfolk, VA
| | - Yun Peng
- Division of Vascular and Endovascular Surgery, Medtronic Inc., Santa Rosa, CA
| | - H Edward Garrett
- Division of Vascular and Endovascular Surgery, University of Tennessee, Memphis, TN
| |
Collapse
|
13
|
Torsello G, Bertoglio L, Kellersmann R, Wever JJ, van Overhagen H, Stavroulakis K. Three-Year Safety and Efficacy of the INCRAFT Endograft for Treatment of Abdominal Aortic Aneurysms: Results of the INSIGHT Study. J Endovasc Ther 2023:15266028231214162. [PMID: 38031973 DOI: 10.1177/15266028231214162] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2023]
Abstract
PURPOSE Preliminary results of the INSIGHT study showed that the low-profile INCRAFT Abdominal Aortic Aneurysm (AAA) Stent-Graft System was safe and effective in the endovascular aneurysm repair (EVAR). This study aimed to assess the durability and the midterm effectiveness of EVAR using the INCRAFT System in the framework of a multicenter, prospective, open-label, post-approval study. MATERIALS AND METHODS Between 2015 and 2016, 150 subjects from 23 European centers treated with the INCRAFT System for an infrarenal AAA were included. Clinical and radiologic data were prospectively collected and analyzed using protocol-specified, monitored follow-up clinic visits at 1, 6, and 12 months post-implantation and annually after that. The clinical success at 3 years was determined. Freedom from overall and aneurysm-related mortality, type I endoleak, secondary interventions, and aneurysm sac enlargement through 3 years were evaluated. Kaplan-Meier estimates were used for late outcomes. An independent clinical events committee reviewed all events. The CT (computed tomography) scans through 1 year were reviewed by an independent core laboratory. RESULTS The primary clinical success rate at 3 years was 84.0% (126/150). There were no aneurysm-related deaths, endograft migration, or aneurysm-related ruptures through 3 years. Stent fracture was detected in 2 subjects (1.3%) without clinical sequelae. Over 3 years, freedom from overall mortality was 89.4%, freedom from secondary interventions was 80%, and freedom from aneurysm sac enlargement was 96.5%. The 3-year freedom from type IA and IB endoleaks was 93.3% and 98.6%, respectively. CONCLUSIONS. In a multicenter real-world study setting, the use of a low-profile INCRAFT device for AAA is associated with sustained clinical success and low rates of reinterventions through 3 years. CLINICAL IMPACT Low-profile endografts have broadened the spectrum of patients with anatomic suitability for endovascular repair of abdominal aortic aneurysms (AAA). However, questions remain regarding the durability of the repair. The INSIGHT study evaluated the use of the INCRAFT System in routine real-world clinical practice, including patients with complex anatomies. The treatment was safe and effective. The results showed sustained clinical success over 3 years, with no aneurysm-related deaths or ruptures, and a high rate of intervention-free survival at 3 years. Despite the low-profile design of the endograft, the midterm results demonstrate the durability of AAA repair using the INCRAFT System.ClinicalTrials.gov Identifier: NCT02477111.
Collapse
Affiliation(s)
- Giovanni Torsello
- Department of Vascular Surgery, St. Franziskus Hospital, Muenster, Germany
| | - Luca Bertoglio
- Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute University, Milan, Italy
| | - Richard Kellersmann
- Clinic and Polyclinic for General, Visceral, Vascular and Pediatric Surgery, University Hospital Würzburg, Würzburg, Germany
| | - Jan J Wever
- Department of Vascular Surgery & Interventional Radiology, Haga Hospital, The Hague, The Netherlands
| | - Hans van Overhagen
- Department of Vascular Surgery & Interventional Radiology, Haga Hospital, The Hague, The Netherlands
| | - Konstantinos Stavroulakis
- Department of Vascular and Endovascular Surgery, University Hospital Münster, Münster, Germany
- Department of Vascular and Endovascular Surgery, Ludwig-Maximilian-University Hospital, Munich, Germany
| |
Collapse
|
14
|
Georgiadis GS, Schoretsanitis N, Argyriou C, Nikolopoulos E, Kapoulas K, Georgakarakos EI, Ktenidis K, Lazarides MK. Long-term outcomes of the Endurant endograft in patients undergoing endovascular abdominal aortic aneurysm repair. J Vasc Surg 2023; 78:668-678.e14. [PMID: 37141949 DOI: 10.1016/j.jvs.2023.04.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2023] [Revised: 04/20/2023] [Accepted: 04/24/2023] [Indexed: 05/06/2023]
Abstract
OBJECTIVE/BACKGROUND To investigate the long-term outcomes after endovascular aneurysm repair (EVAR) in a real-world setting using the Endurant endograft (EG). METHODS 184 EVAR candidates treated with the Endurant family EGs in a single vascular center were prospectively enrolled from January 2009 to December 2016. Kaplan-Meir estimates of long-term standardized primary and secondary outcome measures were performed. Per protocol, subgroup comparison analysis was performed in three groups: patients treated within instructions for use (in-IFU) vs patients treated outside IFU (outside-IFU), EVAR in patients receiving the Endurant proximal diameter 32 or 36 mm EG vs those receiving the <32 mm diameter EG and EVAR with various Endurant EG versions. RESULTS The mean follow-up was 75.09 ± 37.9 months (range: 4.1-172 months). The median age of the patients was 72.96 ± 7.03 years (range: 55-88 years). A total of 177 patients were male (96.2%). Compliance with IFU was followed in 107 patients (58.2%). Overall survival was 69.5% and 48% at 5 and 8 years, respectively. Of the 102 all-cause deaths, 7 (6.9%) were aneurysm related. Six of these postimplant deaths occurred in patients presented with aneurysm rupture from type Ia or/and type Ib endoleak. At 5, 8, and 10 years of observation, freedom from aneurysm rupture, open surgical conversion, type I/III endoleak, any type of endoleak, aneurysm-related secondary intervention probabilities, and neck-related events were as follows: 98.1%, 95%, and 89.4%; 95.1%, 91.2%, and 85.7%; 93.6%, 87.3%, and 83.9%; 83.4%, 74%, and 70.9%; 89.8%, 76.7%, and 72%; and 96.3%, 90%, and 87.6%, respectively. Corresponding clinical success was 90%, 77.4%, and 68.4%, respectively. Patients treated outside-IFU had significantly higher risk of aneurysm rupture, open surgical conversion probability, occurrence of type I/III endoleak, and chance of reinterventions and lower clinical success probabilities compared with the in-IFU counterparts at 5 and 8 years. This statistical difference remained when type Ia endoleak or endoleak of any type was considered independently. In addition, it was stronger in patients having extreme anatomic boundaries (>1 hostile anatomic condition), when aneurysm-related death, aneurysm rupture, and clinical success at 5 years were considered. Overall proximal migration and limb occlusion were recorded in 1.1% and 4.9% of the patients, respectively. Overall reintervention rate was 17.4%. An increase in aneurysm sac diameter was observed in 12.5% of patients and was not related to IFU status. The Endurant version or the proximal EG diameter had no significant association with the chance of any complication or adverse event. CONCLUSIONS The data confirmed the durability of the Endurant EG, achieving promising long-term outcomes in a real-world setting. However, its positive performance must be interpreted with caution in patients treated off-label especially those with extreme anatomic boundaries. In this cohort, some of EVAR advantages might be lost in the late future. Further similar studies are warranted.
Collapse
Affiliation(s)
- George S Georgiadis
- Department of Vascular Surgery, "Democritus" University of Thrace, University General Hospital of Alexandroupolis, Alexandroupolis, Thrace, Greece.
| | | | - Christos Argyriou
- Department of Vascular Surgery, "Democritus" University of Thrace, University General Hospital of Alexandroupolis, Alexandroupolis, Thrace, Greece
| | | | | | - Efstratios I Georgakarakos
- Department of Vascular Surgery, "Democritus" University of Thrace, University General Hospital of Alexandroupolis, Alexandroupolis, Thrace, Greece
| | - Kyriakos Ktenidis
- Department of Vascular Surgery, AHEPA General Hospital of Thessaloniki, Thessaloniki Greece
| | - Miltos K Lazarides
- Department of Vascular Surgery, "Democritus" University of Thrace, University General Hospital of Alexandroupolis, Alexandroupolis, Thrace, Greece
| |
Collapse
|
15
|
Elbayoumi EH, Farres H, Erben Y. Open Repair of a Large Abdominal Aortic Aneurysm With a Type 2 Endoleak After an Endovascular Aortic Aneurysm Repair: A Case Report and Literature Review. Cureus 2023; 15:e40315. [PMID: 37448430 PMCID: PMC10337833 DOI: 10.7759/cureus.40315] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Accepted: 06/01/2023] [Indexed: 07/15/2023] Open
Abstract
A type 2 endoleak (T2E) can occur after an endovascular aortic aneurysm repair (EVAR). The repair of a T2E is recommended after a sac enlargement of ≥5mm. We present a unique case of a 10 cm aneurysm sac that underwent open explantation 11 years after the initial EVAR and after having undergone several interventions to address the T2E.
Collapse
Affiliation(s)
- Eman H Elbayoumi
- Vascular and Endovascular Surgery, Mayo Clinic, Jacksonville, USA
| | - Houssam Farres
- Vascular and Endovascular Surgery, Mayo Clinic, Jacksonville, USA
| | - Young Erben
- Vascular and Endovascular Surgery, Mayo Clinic, Jacksonville, USA
| |
Collapse
|
16
|
Gallitto E, Faggioli G, Mascoli C, Goretti M, Pini R, Logiacco A, Rocchi C, Feroldi F, Caputo S, Gargiulo M. Morphological and Clinical Predictors of Early/Follow-up Failure of the Endovascular Infrarenal Abdominal Aneurysm Repair With Currently Available Endografts. J Endovasc Ther 2023:15266028231158312. [PMID: 36869687 DOI: 10.1177/15266028231158312] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/05/2023]
Abstract
PURPOSE To report outcomes of endovascular repair (EVAR) of infrarenal abdominal aortic aneurysms (AAAs) with currently-available endografts and identify predictors of technical/clinical failure. MATERIALS AND METHODS Patients undergoing EVAR between 2012 and 2020 were prospectively collected and retrospectively analyzed. Technical success (TS: no type I-III endoleaks, renal/hypogastric arteries loss, iliac leg occlusion, conversion to open repair and mortality within 24 postoperative hour), proximal neck-related TS (nr-TS: no proximal type I endoleaks, unplanned renal arteries coverage), and 30-day mortality were assessed as early outcomes. Proximal type I endoleak (ELIa), survival and freedom from reinterventions (FFRs) were assessed during follow-up. Uni/multivariate analysis and Cox-regression were used to identified factors associated with early and follow-up outcomes; FFR and survival were assessed by Kaplan-Meier analysis. RESULTS A total of 710 were included. Technical success and nr-TS were 692 (98%) and 700 (99%), respectively. The presence of ≥2 hostile anatomical infrarenal neck characteristics was associated with technical failure (odds ratio [OR]: 2.4; 95% confidence interval [CI]: 1.3-4.1; p: 0.007). Infrarenal neck angle >90° (OR: 2.88; 95% CI: 9.6-50.3; p: 0.004), barrel shape (OR: 2.33; 95% CI: 11.1-100.3; p: 0.02) or presence of ≥2 hostile anatomical infrarenal neck characteristics (OR: 2.16; 95% CI: 2.5-5.3; p: 0.03) were independent risk factors for neck-related technical failures. Six (0.8%) patients died within 30 postoperative days. Chronic obstructive pulmonary disease (OR: 16; 95% CI: 1.1-218.3; p: 0.04) and urgent repair (OR: 15; 95% CI: 1.8-119.6; p: 0.01) were independent risk factors for 30-day mortality. The mean follow-up was 53±13 months. There were 12 (1.7%) ELIa during follow-up. Infrarenal neck length <15 mm (hazard ratio [HR]: 2.8; 95% CI: 1.9-9.6; p: 0.005), diameter >28 mm (HR: 2.7; 95% CI: 1.6-9.5; p: 0.006), angle ≥90° (HR: 2.7; 95% CI: 8.3-50.1; p: 0.007), and persistent type II endoleak (HR: 2.9; 95% CI: 1.6-10.1; p: 0.004) were independent risk factors for ELIa. Freedom from reintervention was 91% at 5 years. The ELIa was an independent risk factor for reinterventions during follow-up (HR: 29.5; 95% CI: 1.4-1.6; p<0.001). Survival was 74% at 5 years with 2 cases (0.3%) of late aortic-related mortality. Peripheral arterial occlusive disease (HR: 1.9; 95% CI: 1.4-3.65; p: 0.03), aneurysm diameter ≥65 mm (HR: 2.2; 95% CI: 1.4-3.26; p<0.001), and infrarenal neck length <15 mm (HR: 1.7; 95% CI: 1.2-2.35; p: 0.04) were independent risk factors for mortality during follow-up. CONCLUSION Endovascular repair with currently-available endografts has high TS and low 30-day mortality. Survival and FFRs were satisfactory at mid-term. Pre/postoperative risk factors for technical and clinical failure were identified and they should be considered in EVAR indication and postoperative management to reduce complications and improve mid-term outcome. CLINICAL IMPACT Pre and postoperative risk factors for technical and clinical EVAR failure can be identified and they should be considered in EVAR indication and postoperative management to reduce complications and improve mid-term outcome.
Collapse
Affiliation(s)
- Enrico Gallitto
- Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, IRCCS Sant'Orsola Hospital, Bologna, Italy
| | - Gianluca Faggioli
- Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, IRCCS Sant'Orsola Hospital, Bologna, Italy
| | - Chiara Mascoli
- Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, IRCCS Sant'Orsola Hospital, Bologna, Italy
| | - Martina Goretti
- Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, IRCCS Sant'Orsola Hospital, Bologna, Italy
| | - Rodolfo Pini
- Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, IRCCS Sant'Orsola Hospital, Bologna, Italy
| | - Antonino Logiacco
- Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, IRCCS Sant'Orsola Hospital, Bologna, Italy
| | - Cristina Rocchi
- Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, IRCCS Sant'Orsola Hospital, Bologna, Italy
| | - Francesca Feroldi
- Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, IRCCS Sant'Orsola Hospital, Bologna, Italy
| | - Stefania Caputo
- Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, IRCCS Sant'Orsola Hospital, Bologna, Italy
| | - Mauro Gargiulo
- Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, IRCCS Sant'Orsola Hospital, Bologna, Italy
| |
Collapse
|
17
|
Yazar O, Willems S, Salemans PB, Wong CY, van Grinsven B, Bouwman LH. Treatment of Aortoiliac Aneurysms: Compatibility of the E-liac Stent Graft (Artivion ®, Iliac Branch Device) with Endurant II or IIs (Medtronic ®, EVAR). Cardiovasc Intervent Radiol 2023; 46:187-193. [PMID: 36624291 DOI: 10.1007/s00270-022-03352-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Accepted: 12/25/2022] [Indexed: 01/10/2023]
Abstract
PURPOSE Iliac branch devices (IBD) are widely used to treat aortoiliac aneurysms with an unfit distal landing zone for standard endovascular aneurysm repair (EVAR). The aim of this retrospective study was to examine the treatment of aortoiliac aneurysms with the combination of the Endurant II(s) stent graft system (Medtronic®) and the E-liac stent graft (Artivion®). MATERIALS AND METHODS Data of all patients who underwent an EVAR combined with unilateral or bilateral IBD between January 2015 and January 2020 were analyzed. Primary outcomes were technical success at implantation (successful EVAR with IBD extension placement and patency of the grafts without type 1 or type 3 endoleak), and type 1b/3 endoleak, hypogastric artery patency and IBD-related reinterventions during follow-up. Secondary outcomes were all type 1 endoleak, all reinterventions, rupture, and mortality during follow-up. RESULTS A total of 38 patients were treated with a combination of EVAR with IBD. Technical success was 94.7% (n = 36/38). The 30-day survival was 100%. Median follow-up time was 31 months (range 8-56). During follow-up, no patients developed type 1b or type 3 endoleak and all hypogastric arteries at the side of IBD remained patent. The overall reintervention rate at 12 months follow-up was 5.3% (n = 2/38) and the IBD-related reintervention rate was 2.6% (n = 1/38). CONCLUSION The combination of the Endurant II(s) and the E-liac stent graft system is an effective and safe procedure for patients with an aortoiliac aneurysm. We confirm the high hypogastric artery patency rate using IBD. Furthermore, these devices have a high technical success rate even when it is combined with an Endurant II(s) EVAR main body.
Collapse
Affiliation(s)
- Ozan Yazar
- Department of Vascular and Endovascular Surgery, Zuyderland Medical Center, Henri Dunantstraat 5, 6419PC, Heerlen, The Netherlands.
| | - Stefanie Willems
- Department of Vascular and Endovascular Surgery, Zuyderland Medical Center, Henri Dunantstraat 5, 6419PC, Heerlen, The Netherlands
| | - Pieter B Salemans
- Department of Vascular and Endovascular Surgery, Zuyderland Medical Center, Henri Dunantstraat 5, 6419PC, Heerlen, The Netherlands
| | - Chun-Yu Wong
- Department of Vascular and Endovascular Surgery, Zuyderland Medical Center, Henri Dunantstraat 5, 6419PC, Heerlen, The Netherlands
| | - Bart van Grinsven
- Faculty of Science and Engineering, Maastricht University, Maastricht, The Netherlands
| | - Lee H Bouwman
- Department of Vascular and Endovascular Surgery, Zuyderland Medical Center, Henri Dunantstraat 5, 6419PC, Heerlen, The Netherlands.,Faculty of Science and Engineering, Maastricht University, Maastricht, The Netherlands
| |
Collapse
|
18
|
van Basten Batenburg M, 't Mannetje YW, van Sambeek MRHM, Cuypers PWM, Georgiadis GS, Sondakh AO, Teijink JAW. Editor's Choice - Endurant Stent Graft in Patients with Challenging Neck Anatomy "One Step Outside Instructions for Use": Early and Midterm Results from the EAGLE Registry. Eur J Vasc Endovasc Surg 2022; 64:611-619. [PMID: 35987507 DOI: 10.1016/j.ejvs.2022.08.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Revised: 07/27/2022] [Accepted: 08/06/2022] [Indexed: 01/12/2023]
Abstract
OBJECTIVE The aim of the Endurant for Challenging Anatomy: Global Experience (EAGLE) registry is to evaluate prospectively the technical and clinical success rate of a stentgraft used in patients with challenging neck anatomy outside the instructions for use (IFU) but within objective anatomical limits. METHODS This was a prospective, international, multicentre, observational study. From 1 February 2012 to 1 September 2017, patients with an abdominal aortic aneurysm with a challenging infrarenal neck that were deemed suitable for endovascular aneurysm repair were included prospectively at 23 European centres. Patients were distributed by anatomy into three groups: short neck (SN; infrarenal neck 5 - 10 mm in combination with suprarenal angulation [α] ≤ 45° and infrarenal angulation [β] ≤ 60°); medium neck (MN; infrarenal neck 10 - 15 mm with α ≤ 60° and β 60° - 75° or α 45°- 60° and β ≤ 75°; and long angulated neck (LN; infrarenal neck ≥ 15 mm with α ≤ 75° and β 75°- 90° or α 60°- 75° and β ≤ 90°. All computed tomography scans were reviewed by an independent core laboratory. Primary outcomes were technical and clinical success. Secondary endpoints were peri-operative major adverse events, all cause mortality, aneurysm related mortality, endoleaks, migration, and secondary intervention. RESULTS One hundred and fifty patients (81.3% male) were included (SN = 55, MN = 16, LN = 79). The median follow up was 36 ± 12.6 months. In the overall cohort, the technical success rate was 93.3%. Estimated freedom from aneurysm related death was 97.3% at three years. Freedom from secondary interventions was 84.7% at three years. Estimated clinical success was 96.0%, 90.8%, and 83.2% at 30 days, one year, and three years, respectively. Estimated freedom from all cause mortality, late type IA endoleak, and migration at three years was 75.1%, 93.7%, and 99.3%, respectively. CONCLUSION The early and midterm results of the EAGLE registry show that endovascular repair with the Endurant stentgraft in selected patients with challenging infrarenal neck anatomy yields results in line with large "real world" registries. Long term results are awaited for more definitive conclusions.
Collapse
Affiliation(s)
- Michael van Basten Batenburg
- Department of Vascular Surgery, Catharina Hospital, Eindhoven, the Netherlands; Department of Epidemiology, CAPHRI Research School, Maastricht University, the Netherlands
| | - Yannick W 't Mannetje
- Department of Vascular Surgery, Catharina Hospital, Eindhoven, the Netherlands; Department of Epidemiology, CAPHRI Research School, Maastricht University, the Netherlands
| | - Marc R H M van Sambeek
- Department of Vascular Surgery, Catharina Hospital, Eindhoven, the Netherlands; Department of Cardiovascular Biomechanics, University of Technology Eindhoven, the Netherlands
| | | | - George S Georgiadis
- Department of Vascular Surgery, "Democritus" University of Thrace, University General Hospital of Alexandroupolis, Thrace, Greece
| | - Arthur O Sondakh
- Department of Vascular Surgery, Sint Jans Gasthuis, Weert, the Netherlands
| | - Joep A W Teijink
- Department of Vascular Surgery, Catharina Hospital, Eindhoven, the Netherlands; Department of Epidemiology, CAPHRI Research School, Maastricht University, the Netherlands.
| | | |
Collapse
|
19
|
Liu Y, Qing M, Zhao J, Huang B, Yang Y, Zheng T, Yuan D. Influence of severe neck angulation on hemodynamic and clinical outcomes following endovascular aneurysm repair: a hemodynamic analysis and a retrospective cohort study. Chin Med J (Engl) 2022; 135:2577-2584. [PMID: 36583921 PMCID: PMC9943978 DOI: 10.1097/cm9.0000000000002280] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Indexed: 12/31/2022] Open
Abstract
BACKGROUND For patients with severe neck angulation (SNA), hemodynamic and clinical outcomes following endovascular aneurysm repair (EVAR) are still unclear. This study aimed to explore the influence of SNA on hemodynamic and clinical outcomes following EVAR. METHODS This study included a hemodynamic analysis and a retrospective cohort study from West China Hospital of Sichuan University between January 2011 and December 2020. The Cox regression model, inverse probability of treatment weighting (IPTW) analysis, sensitivity analysis, and subgroup analysis were applied. Primary outcome was type IA endoleak (T1AEL). RESULTS In this hemodynamic analysis, nine non-severe neck angulation (nSNA) and 16 SNA idealized models were constructed. We found a significant difference in drag force between SNA and nSNA models (7.016 ± 2.579 N vs. 4.283 ± 1.460 N, P = 0.008), and proximal neck angles were significantly associated with the magnitude of drag force (F = 0.082 × α-0.006 × β + 2.818, α: 95% confidence interval [CI] 0.070-0.094; P = 0.001; β: 95% CI -0.019 to 0.007; P = 0.319). In our cohort study, 514 nSNA patients (71.5 ± 8.5 years; 459 males) and 208 SNA patients (72.5 ± 7.8 years; 135 males) were included, with a median follow-up duration of 34 months (16-63 months). All baseline characteristics were well balanced after IPTW matching. We found that SNA was associated with a significant risk of adverse limb event (hazard ratio [HR] 2.18, 95% CI 1.09-3.12), yet was not associated with T1AEL, overall survival, or reintervention. In patients without proximal or distal additional procedures (DAP), subgroup analyses suggested a significant risk of T1AEL (Proximal: HR 5.25, 95% CI 1.51-18.23; Distal: HR 5.07, 95% CI 1.60-16.07) and adverse limb event (Proximal: HR 2.27, 95% CI 1.01-5.07; Distal: HR 2.91, 95% CI 1.30-6.54) in SNA patients. However, no noticeable difference was observed in patients with proximal or DAP. CONCLUSIONS SNA has a critical influence on hemodynamic and clinical outcomes following EVAR. Appropriate additional procedures may be of great benefit to SNA patients.
Collapse
Affiliation(s)
- Yang Liu
- Department of Vascular Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Ming Qing
- Department of Applied Mechanics, Sichuan University, Chengdu, Sichuan 610065, China
| | - Jichun Zhao
- Department of Vascular Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Bin Huang
- Department of Vascular Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Yi Yang
- Department of Vascular Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Tinghui Zheng
- Department of Applied Mechanics, Sichuan University, Chengdu, Sichuan 610065, China
| | - Ding Yuan
- Department of Vascular Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| |
Collapse
|
20
|
Vedani SM, Petitprez S, Weinz E, Corpataux JM, Déglise S, Deslarzes-Dubuis C, Côté E, Ricco JB, Saucy F. Predictors and Consequences of Sac Shrinkage after Endovascular Infrarenal Aortic Aneurysm Repair. J Clin Med 2022; 11:jcm11113232. [PMID: 35683617 PMCID: PMC9181709 DOI: 10.3390/jcm11113232] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Revised: 05/28/2022] [Accepted: 06/01/2022] [Indexed: 11/16/2022] Open
Abstract
Background: Aneurysm shrinkage has been proposed as a marker of successful endovascular aneurysm repair (EVAR). We evaluated the impact of sac shrinkage on secondary interventions, on survival and its association with endoleaks, and on compliance with instructions for use (IFU). Methods: This observational retrospective study was conducted on all consecutive patients receiving EVAR for an infrarenal abdominal aortic aneurysm (AAA) using exclusively Endurant II/IIs endograft from 2014 to 2018. Sixty patients were entered in the study. Aneurysm sac shrinkage was defined as decrease ≥5 mm of the maximum aortic diameter. Univariate methods and Kaplan–Meier plots assessed the potential impact of shrinkage. Results: Twenty-six patients (43.3%) experienced shrinkage at one year, and thirty-four (56.7%) had no shrinkage. Shrinkage was not significantly associated with any demographics or morbidity, except hypertension (p = 0.01). No aneurysm characteristics were associated with shrinkage. Non-compliance with instructions for use (IFU) in 13 patients (21.6%) was not associated with shrinkage. Three years after EVAR, freedom from secondary intervention was 85 ± 2% for the entire series, 92.3 ± 5.0% for the shrinkage group and 83.3 ± 9% for the no-shrinkage group (Logrank: p = 0.49). Survival at 3 years was not significantly different between the two groups (85.9 ± 7.0% vs. 79.0 ± 9.0%, Logrank; p = 0.59). Strict compliance with IFU was associated with less reinterventions at 3 years (92.1 ± 5.9% vs. 73.8 ± 15%, Logrank: p = 0.03). Similarly, survival at 3 years did not significantly differ between strict compliance with IFU and non-compliance (81.8 ± 7.0% vs. 78.6 ± 13.0%, Logrank; p = 0.32). Conclusion: This study suggests that shrinkage ≥5 mm at 1-year is not significantly associated with a better survival rate or a lower risk of secondary intervention than no-shrinkage. In this series, the risk of secondary intervention regardless of shrinkage seems to be linked more to non-compliance with IFU. Considering the small number of patients, these results must be confirmed by extensive prospective studies.
Collapse
Affiliation(s)
- Sébastien Michel Vedani
- Department of Vascular Surgery, Centre Hospitalier Universitaire Vaudois, 1011 Lausanne, Switzerland; (S.M.V.); (S.P.); (E.W.); (J.-M.C.); (S.D.); (C.D.-D.); (E.C.)
| | - Séverine Petitprez
- Department of Vascular Surgery, Centre Hospitalier Universitaire Vaudois, 1011 Lausanne, Switzerland; (S.M.V.); (S.P.); (E.W.); (J.-M.C.); (S.D.); (C.D.-D.); (E.C.)
| | - Eva Weinz
- Department of Vascular Surgery, Centre Hospitalier Universitaire Vaudois, 1011 Lausanne, Switzerland; (S.M.V.); (S.P.); (E.W.); (J.-M.C.); (S.D.); (C.D.-D.); (E.C.)
| | - Jean-Marc Corpataux
- Department of Vascular Surgery, Centre Hospitalier Universitaire Vaudois, 1011 Lausanne, Switzerland; (S.M.V.); (S.P.); (E.W.); (J.-M.C.); (S.D.); (C.D.-D.); (E.C.)
| | - Sébastien Déglise
- Department of Vascular Surgery, Centre Hospitalier Universitaire Vaudois, 1011 Lausanne, Switzerland; (S.M.V.); (S.P.); (E.W.); (J.-M.C.); (S.D.); (C.D.-D.); (E.C.)
| | - Céline Deslarzes-Dubuis
- Department of Vascular Surgery, Centre Hospitalier Universitaire Vaudois, 1011 Lausanne, Switzerland; (S.M.V.); (S.P.); (E.W.); (J.-M.C.); (S.D.); (C.D.-D.); (E.C.)
| | - Elisabeth Côté
- Department of Vascular Surgery, Centre Hospitalier Universitaire Vaudois, 1011 Lausanne, Switzerland; (S.M.V.); (S.P.); (E.W.); (J.-M.C.); (S.D.); (C.D.-D.); (E.C.)
| | - Jean-Baptiste Ricco
- Department of Clinical Research, University of Poitiers, 86073 Poitiers, France;
| | - François Saucy
- Department of Vascular Surgery, Centre Hospitalier Universitaire Vaudois, 1011 Lausanne, Switzerland; (S.M.V.); (S.P.); (E.W.); (J.-M.C.); (S.D.); (C.D.-D.); (E.C.)
- Service of Vascular Surgery, Ensemble Hospitalier de la Côte, 1110 Morges, Switzerland
- Correspondence:
| |
Collapse
|
21
|
Kemmling S, Wiedner M, Stahlberg E, Sieren M, Jacob F, Barkhausen J, Goltz JP. Five-year outcomes of the Bi- versus Trimodular EndurantTM stent-graft in 100 patients with infrarenal abdominal aortic repair. THE JOURNAL OF CARDIOVASCULAR SURGERY 2022; 63:308-316. [PMID: 35343657 DOI: 10.23736/s0021-9509.22.11947-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
BACKGROUND Recent studies on the Endurant™ endografts mainly compared outcomes of the bimodular stent-graft to other manufacturer's endografts or reported results for cases outside manufacturer's instructions for use (IFU), while data on the experience of standard endovascular aortic repair (EVAR) of infrarenal abdominal aortic aneurysms (AAA) inside manufacturer's IFU comparing the bi- with the trimodular device is limited. METHODS Inclusion criteria were: 1) infrarenal aneurysms (>50 mm diameter) treated by EndurantTM II (END II) or EndurantTM IIs (END IIs) stent-graft inside manufacturer's IFU; 2) available CTA with 1 mm reconstruction of the entire aorta prior to intervention. Endpoints comparing the devices included technical success, 30-day mortality, rate of complications (bleeding with conversion to open repair, stent-graft stenosis/occlusion, acute distal embolism, infection or postprocedural necessity of dialysis), endoleaks and reinterventions (5-year follow-up). Aneurysm sac diameters were compared between baseline preinterventional CTA and last post-interventional CTA. RESULTS One hundred patients (90% male, mean age 74 years) treated with END II (N.=66) or END IIs (N.=34) were included. Technical success was 99%. One procedure-related active bleeding occurred ending up in surgical conversion (END II N.=1). 30d mortality was 0%. No initial type I/III endoleaks were present. Re-interventions were required in 19/100 (19%) of patients (END II N.=10; END IIs N.=9, P=0.17). The outcome of EVAR including technical success, 30d mortality, rate of complications, endoleaks and re-interventions showed no significant differences comparing END II/IIs. CONCLUSIONS Five-year outcomes of EVAR show consistently safe and effective results for either END II or IIs device.
Collapse
Affiliation(s)
- Susanne Kemmling
- Department for Radiology and Nuclear Medicine, University Hospital of Schleswig Holstein, Lübeck, Germany -
| | - Marcus Wiedner
- Department for Surgery, University Hospital of Schleswig Holstein, Lübeck, Germany
| | - Erik Stahlberg
- Department for Radiology and Nuclear Medicine, University Hospital of Schleswig Holstein, Lübeck, Germany
| | - Malte Sieren
- Department for Radiology and Nuclear Medicine, University Hospital of Schleswig Holstein, Lübeck, Germany
| | - Fabian Jacob
- Department for Radiology and Nuclear Medicine, University Hospital of Schleswig Holstein, Lübeck, Germany
| | - Joerg Barkhausen
- Department for Radiology and Nuclear Medicine, University Hospital of Schleswig Holstein, Lübeck, Germany
| | - Jan P Goltz
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, SANA Clinic, Lübeck, Germany
| |
Collapse
|
22
|
Sekimoto Y, Fujimura N, Matsubara K, Uchida N, Asami A, Harada H, Shintani T, Watada S, Ono S, Fujii T, Shimogawara T, Hayashi K, Hayashi M, Obara H, Kitagawa Y. Long-term Outcomes of the Endurant and Excluder Stent Grafts for Endovascular Aneurysm Repair in a Japanese Cohort. J Endovasc Ther 2022:15266028221090441. [PMID: 35414228 DOI: 10.1177/15266028221090441] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE To compare the long-term outcomes of the most widely used third-generation stent grafts, the Endurant and Excluder stent grafts, in Japanese patients using a multicenter registry. MATERIALS AND METHODS A retrospective analysis of endovascular aneurysm repairs for abdominal aortic and iliac artery aneurysms using either the Endurant or the Excluder stent grafts from January 2012 to July 2019 at 10 Japanese hospitals was performed. RESULTS A total of 332 and 378 repairs using the Endurant and Excluder stent grafts, respectively, were analyzed. Although the patients' characteristics were generally similar in the two groups, the Endurant group exhibited significantly shorter (Endurant: 31.5±18.6 mm, Excluder: 37.4±21.0 mm; p<0.001), larger (Endurant: 22.4±4.2 mm, Excluder: 21.7±3.8 mm; p=0.029), and more reversed tapered (Endurant: 12.1%, Excluder: 5.8%; p=0.003) proximal necks. The incidence of instructions for use (IFU) violations was similar between the two groups (Endurant: 59.0%, Excluder: 54.5%; p=0.223). However, the Endurant group had significantly more proximal neck-related IFU violations (54.1% and 46.3%, respectively; p=0.039), more access-related IFU violations (8.1% and 4.0%, respectively; p=0.019), and fewer bilateral hypogastric artery embolizations (5.1% and 9.3%, respectively; p=0.035) compared with the Excluder group. The incidence of intraoperative (Endurant: 3.6%, Excluder: 3.7%; p=0.950) and perioperative complications (Endurant: 3.6%, Excluder: 3.4%, p=0.899) was equivalent in the two groups. However, there was a significantly higher incidence of postoperative type II endoleaks in the Excluder group (Endurant: 28%, Excluder: 46.0%, p<0.001). Aneurysm sac regression was more frequent in the Endurant group (Endurant: 40.7%, Excluder: 31.7%, p=0.013). The Endurant group also had significantly higher rates of sac increase (Endurant: 13.0%, Excluder: 7.7%, p=0.020). Kaplan-Meier curve and log-rank analyses revealed no statistical differences in late complications (p=0.868) and overall survival (p=0.926). CONCLUSIONS There were no statistically significant differences between the Endurant and the Excluder stent grafts in terms of intraoperative, perioperative, and late complication rates; however, the anatomical characteristics of the patients were significantly different.
Collapse
Affiliation(s)
- Yasuhito Sekimoto
- Department of Surgery, National Hospital Organization Tokyo Medical Center, Tokyo, Japan
| | - Naoki Fujimura
- Department of Vascular Surgery, Saiseikai Central Hospital, Tokyo, Japan
| | - Kentaro Matsubara
- Department of Surgery, Keio University School of Medicine, Tokyo, Japan
| | - Norio Uchida
- Department of Surgery, Mito Red Cross Hospital, Ibaraki, Japan
| | - Atsunori Asami
- Department of Surgery, Saitama Municipal Hospital, Saitama, Japan
| | - Hirohisa Harada
- Department of Vascular Surgery, Saiseikai Central Hospital, Tokyo, Japan
| | - Tsunehiro Shintani
- Department of Vascular Surgery, Shizuoka Red Cross Hospital, Shizuoka, Japan
| | - Susumu Watada
- Department of Surgery, Tokyo Dental College Ichikawa General Hospital, Chiba, Japan
| | - Shigeshi Ono
- Department of Vascular Surgery, Saiseikai Yokohamashi Tobu Hospital, Kanagawa, Japan
| | - Taku Fujii
- Department of Surgery, Saitama Municipal Hospital, Saitama, Japan
| | | | - Keita Hayashi
- Department of Surgery, Hiratsuka City Hospital, Kanagawa, Japan
| | - Masanori Hayashi
- Department of Vascular Surgery, Shizuoka Red Cross Hospital, Shizuoka, Japan
| | - Hideaki Obara
- Department of Surgery, Keio University School of Medicine, Tokyo, Japan
| | - Yuko Kitagawa
- Department of Surgery, Keio University School of Medicine, Tokyo, Japan
| |
Collapse
|
23
|
De Guerre LEVM, O'Donnell TFX, Varkevisser RRB, Swerdlow NJ, Li C, Dansey K, van Herwaarden JA, Schermerhorn ML, Patel VI. The Association between Device Instructions for Use Adherence and Outcomes after Elective Endovascular Aortic Abdominal Aneurysm Repair. J Vasc Surg 2022; 76:690-698.e2. [PMID: 35276256 DOI: 10.1016/j.jvs.2022.02.037] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2020] [Accepted: 02/14/2022] [Indexed: 11/17/2022]
Abstract
OBJECTIVE Aortic neck anatomy has a significant impact on the complexity of endovascular aortic aneurysm repair (EVAR), with concern that neck characteristics outside of instructions for use (IFU) may result in worse outcomes. Therefore, this study determined the impact of neck characteristics outside of IFU on perioperative and one-year outcomes and mid-term survival after EVAR. METHODS We identified all patients undergoing elective infrarenal EVAR from December 2014 to May 2020 in the Vascular Quality Initiative database. Neck characteristics outside of IFU were determined based the specific device IFU neck characteristics (Neck diameter, length, and angulation). Patients without one-year follow-up were excluded for the 1-year outcomes analyses (n=6,138 (40%)). We used multivariable adjusted logistic regression and Cox proportional hazard models to identify the independent associations between neck characteristics outside of IFU and our outcomes. RESULTS Of the 15,448 patients identified, 22.1% had neck characteristics outside of IFU, including 6.6% with a infrarenal angle, 6.8% with a neck length, 10.4% with a neck diameter, and 1.1% with a suprarenal angulation outside of IFU. Of these, 2.4% had more than one neck characteristic outside of IFU. Patients with neck characteristics outside of IFU were more often female (27.9% vs. 15.0%, P<.001) and were older (median age 75 vs. 73, P<.001). EVAR patients with neck characteristics outside of IFU had higher rates of type Ia endoleaks at completion (4.8% vs. 2.5%, P<.001), perioperative mortality (1.2% vs. 0.6%, P<.001), one-year sac expansion (7.1% vs. 5.3%, P=.017), and one-year reinterventions (4.4% vs. 3.2%, P=.03). In multivariable adjusted analyses, neck characteristics outside of IFU were independently associated with type Ia completion endoleaks (OR 1.6, [1.3-2.0], P<.001), perioperative mortality (OR 1.8; [1.2-2.7]; P=.005), one-year sac expansion (OR 1.4; [1.0-1.8]; P=.025) and one-year reinterventions (OR 1.4; [1.0-1.9]; P=.039). Unadjusted mid-term survival was lower for patients with neck characteristics outside of IFU than for patients without (5-year survival 84.0% vs. 86.7%, log-rank<.001). However, after adjustment, survival was similar for patients with neck characteristics outside of IFU to those within (HR: 1.1; [1.0-1.3]; P=.22). CONCLUSION Neck characteristics outside of IFU are independently associated with completion type Ia endoleaks, perioperative mortality, one-year sac expansion and one-year reinterventions among patients undergoing elective EVAR. These results indicate that continued effort is needed to improve the proximal seal in patients with neck characteristics outside of IFU undergoing EVAR. Also, in patients with severe hostile neck characteristics, alternative approaches such as open repair, use of a fenestrated or branched device, or endoanchors should be considered.
Collapse
Affiliation(s)
- Livia E V M De Guerre
- Divisions of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Boston, MA; Department of Vascular Surgery, University Medical Center, Utrecht, The Netherlands
| | - Thomas F X O'Donnell
- Divisions of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Boston, MA
| | - Rens R B Varkevisser
- Divisions of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Boston, MA
| | - Nicholas J Swerdlow
- Divisions of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Boston, MA
| | - Chun Li
- Divisions of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Boston, MA
| | - Kirsten Dansey
- Divisions of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Boston, MA
| | | | - Marc L Schermerhorn
- Divisions of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Boston, MA
| | - Virendra I Patel
- Division of Vascular and Endovascular Surgery, New York Presbyterian/Columbia University Irving Medical Center/ Columbia University Vagelos College of Physicians & Surgeons, New York, NY 10032.
| |
Collapse
|
24
|
van Rijswijk RE, Groot Jebbink E, Holewijn S, Stoop N, van Sterkenburg SM, Reijnen MMPJ. Predictors of Abdominal Aortic Aneurysm Shrinkage after Endovascular Repair. J Clin Med 2022; 11:jcm11051394. [PMID: 35268486 PMCID: PMC8910935 DOI: 10.3390/jcm11051394] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Revised: 02/24/2022] [Accepted: 02/25/2022] [Indexed: 02/01/2023] Open
Abstract
Recent studies demonstrate that patients with a shrinking abdominal aortic aneurysm (AAA), one-year after endovascular repair (EVAR), have better long-term outcomes than patients with a stable AAA. It is not known what factors determine whether an AAA will shrink or not. In this study, a range of parameters was investigated to identify their use in differentiating patients that will develop a shrinking AAA from those with a stable AAA one-year after EVAR. Hundred-seventy-four patients (67 shrinking AAA, 107 stable AAA) who underwent elective, infrarenal EVAR were enrolled between 2011-2018. Long-term survival was significantly better in patients with a shrinking AAA, compared to those with a stable AAA (p = 0.038). Larger preoperative maximum AAA diameter was associated with an increased likelihood of developing AAA shrinkage one-year after EVAR-whereas older age and larger preoperative infrarenal β angle were associated with a reduced likelihood of AAA shrinkage. However, this multivariate logistic regression model was only able to correctly identify 66.7% of patients with AAA shrinkage from the total cohort. This is not sufficient for implementation in clinical care, and therefore future research is recommended to dive deeper into AAA anatomy, and explore potential predictors using artificial intelligence and radiomics.
Collapse
Affiliation(s)
- Rianne E. van Rijswijk
- Department of Vascular Surgery, Rijnstate, 6815 AD Arnhem, The Netherlands; (E.G.J.); (S.H.); (N.S.); (S.M.v.S.); (M.M.P.J.R.)
- Multi-Modality Medical Imaging Group, TechMed Centre, University of Twente, 7522 NH Enschede, The Netherlands
- Correspondence:
| | - Erik Groot Jebbink
- Department of Vascular Surgery, Rijnstate, 6815 AD Arnhem, The Netherlands; (E.G.J.); (S.H.); (N.S.); (S.M.v.S.); (M.M.P.J.R.)
- Multi-Modality Medical Imaging Group, TechMed Centre, University of Twente, 7522 NH Enschede, The Netherlands
| | - Suzanne Holewijn
- Department of Vascular Surgery, Rijnstate, 6815 AD Arnhem, The Netherlands; (E.G.J.); (S.H.); (N.S.); (S.M.v.S.); (M.M.P.J.R.)
| | - Nicky Stoop
- Department of Vascular Surgery, Rijnstate, 6815 AD Arnhem, The Netherlands; (E.G.J.); (S.H.); (N.S.); (S.M.v.S.); (M.M.P.J.R.)
| | - Steven M. van Sterkenburg
- Department of Vascular Surgery, Rijnstate, 6815 AD Arnhem, The Netherlands; (E.G.J.); (S.H.); (N.S.); (S.M.v.S.); (M.M.P.J.R.)
| | - Michel M. P. J. Reijnen
- Department of Vascular Surgery, Rijnstate, 6815 AD Arnhem, The Netherlands; (E.G.J.); (S.H.); (N.S.); (S.M.v.S.); (M.M.P.J.R.)
- Multi-Modality Medical Imaging Group, TechMed Centre, University of Twente, 7522 NH Enschede, The Netherlands
| |
Collapse
|
25
|
Schoretsanitis N, Georgakarakos E, Argyriou C, Lazarides M, Ktenidis K, Papanas N, Deftereos S, Georgiadis GS. The Incraft stent graft for the treatment of abdominal aortic aneurysms: an iliac-friendly device with an effective conventional proximal sealing mechanism. Expert Rev Med Devices 2021; 19:37-41. [PMID: 34937480 DOI: 10.1080/17434440.2022.2020096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
INTRODUCTION The Incraft aortic stent graft (Cordis, Bridgewater, NJ, USA) is a trimodular endovascular stent graft with a conventional suprarenal active fixation specifically designed to overcome the anatomic limitation of small, stenotic, and tortuous iliac vessels. AREAS COVERED The present article provides a complete description of the Incraft stent graft, its clinical performance, its technical characteristics as well as a comparison with other competitive endografts. EXPERT OPINION The Incraft stent graft is an EVAR ultra low-profile device initially designed for overcoming the limitation of the hostile iliac anatomy. Recently, the device is being increasingly used in real-world conditions and not only in complex iliac anatomies with good mid-term results. Whether it remains a useful EVAR toolbox or will become a workhorse endograft is yet to be determined.
Collapse
Affiliation(s)
- Nikolaos Schoretsanitis
- Department of Vascular Surgery, "Democritus" University of Thrace, University Hospital of Alexandroupolis, Alexandroupolis, Greece
| | - Efstratios Georgakarakos
- Department of Vascular Surgery, "Democritus" University of Thrace, University Hospital of Alexandroupolis, Alexandroupolis, Greece
| | - Christos Argyriou
- Department of Vascular Surgery, "Democritus" University of Thrace, University Hospital of Alexandroupolis, Alexandroupolis, Greece
| | - Miltos Lazarides
- Department of Vascular Surgery, "Democritus" University of Thrace, University Hospital of Alexandroupolis, Alexandroupolis, Greece
| | - Kiriakos Ktenidis
- Vascular Surgery Unit, 1st Propaedeutic Surgical Department, Ahepa University Hospital of Thessaloniki, Thessaloniki, Greece
| | - Nikolaos Papanas
- Diabetes Centre, Second Department of Internal Medicine, Democritus University of Thrace, Alexandroupolis, Greece
| | - Savas Deftereos
- Radiology Department, Democritus University of Thrace, Alexandroupolis, Greece
| | - George S Georgiadis
- Department of Vascular Surgery, "Democritus" University of Thrace, University Hospital of Alexandroupolis, Alexandroupolis, Greece
| |
Collapse
|
26
|
de Donato G, Pasqui E, Nano G, Lenti M, Mangialardi N, Speziale F, Ferrari M, Michelagnoli S, Tozzi M, Palasciano G. Long-term results of low-profile stent grafts for treatment of infrarenal aortic aneurysms: Results from a retrospective multicenter registry. J Vasc Surg 2021; 75:1242-1252.e2. [PMID: 34634415 DOI: 10.1016/j.jvs.2021.09.036] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2021] [Accepted: 09/15/2021] [Indexed: 12/22/2022]
Abstract
OBJECTIVE In recent years, manufacturers have developed new stent grafts with lower profiles to increase the endovascular aneurysm repair applicability. As reported by the current European Society for Vascular Surgery guidelines, long-term evaluation of such low-profile platforms is strongly recommended. This study aims to report outcomes beyond 5 years from a multicenter registry, including a real-world cohort of patients electively treated with low-profile stent grafts. METHODS A retrospective data collection of patients who had undergone elective implantation of low-profile endograft ≤16 Fr. (Zenith LP, Ovation, Incraft) was performed in nine centers. The primary endpoint was a long-term primary clinical success. Secondary endpoints were survival rate, freedom from abdominal aortic aneurysm (AAA)-related death, freedom from type I to III endoleak, limb patency, and freedom from all reinterventions. The Kaplan-Meier curves were stratified for investigative devices. A multivariate analysis evaluated predictors of primary clinical success and reintervention rate. RESULTS A total of 619 patients were enrolled (Ovation, n = 373; Incraft, n = 111; and Zenith LP, n = 135), with a mean follow-up of 56.8 ± 22.8 months. The overall primary and the secondary clinical success rate at 8 years was 72.1% and 93.8%, respectively. At 8 years, overall survival was 53.2%, freedom from AAA-related death was 94.4%, freedom from reintervention was 74%, freedom from type I/III endoleak was 86.9%, and limb patency was 90.4%. A significantly worse primary clinical success of the Zenith LP was recorded as dependent on more limb-related events. No differences between platforms were registered in the rate of AAA-related deaths, open conversion, sac enlargement, and type I/III endoleaks (P = .26). Multivariate analysis identified iliac tortuosity (hazard ratio, 2.053) and Zenith LP (hazard ratio, 3.818) as significant independent predictors of clinical failure and reintervention. CONCLUSION Low-profile stent grafts have acceptable long-term outcomes. Overall survival and AAA-related death were in line with those reported for traditional devices. Long-term surveillance and reintervention, when necessary, remain crucial to guarantee durability.
Collapse
Affiliation(s)
| | - Edoardo Pasqui
- Department of Vascular Surgery, University of Siena, Siena, Italy
| | - Giovanni Nano
- Department of Vascular Surgery, IRCCS Policlinico San Donato, Milan, Italy
| | - Massimo Lenti
- Department of Vascular Surgery, University of Perugia, Perugia, Italy
| | | | - Francesco Speziale
- Department of Vascular Surgery, La Sapienza University of Rome, Rome, Italy
| | - Mauro Ferrari
- Department of Vascular Surgery, University of Pisa, Pisa, Italy
| | | | - Matteo Tozzi
- Department of Vascular Surgery, University of Insubria, Insubria, Italy
| | | | | |
Collapse
|
27
|
What factors counteract mid-term survival following endovascular repair of abdominal aortic aneurysms? POLISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY 2021; 18:8-14. [PMID: 34552638 PMCID: PMC8442091 DOI: 10.5114/kitp.2021.105179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/27/2020] [Accepted: 01/28/2021] [Indexed: 11/17/2022]
Abstract
Introduction Endovascular aortic aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA) is increasingly used, and has become the standard treatment option for AAA. Aim To evaluate the outcomes and predictors of survival of endovascular treatment of AAA in the short- and medium-term. Material and methods A total of 222 patients having endovascular AAA repair between January 2013 and December 2019 by the same surgical team were included in the study. Patient demographics, perioperative and follow-up data including mortality, complications, and need for secondary intervention were collected. The primary endpoint was all-cause mortality. Kaplan-Meier analysis was conducted for survival and Cox regression models were assessed for predictors of survival. Results The median age was 70 years, with male predominance (202 patients, 91%). Thirty-day mortality was 1.8%. Median follow-up to the primary endpoint was 20 months (range: 1–80 months). Survival rates at 1, 3, and 5 years were 93.5%, 81.4%, and 62.2%, respectively. Freedom from secondary intervention rates were 95.5% at 1 year, 88.7% at 3 years, and 82.1% at 5 years. Cox proportional hazard models showed that preoperative creatinine levels ≥ 1.8 mg/dl (hazard ratio (HR) = 2.68, 95% CI: 1.21–6.42, p = 0.027), haemoglobin levels < 10 gr/dl (HR = 3.38, 95% CI: 1.16–9.90, p = 0.026), ejection fraction < 30% (HR = 5.67, 95% CI: 1.29–24.86, p = 0.021), and AAA diameter ≥ 6.0 cm (HR = 2.20, 95% CI: 1.01–4.81, p = 0.049) were independently associated with mid-term survival. Conclusions EVAR is a safe procedure with low postoperative morbidity and mortality. This study confirms that the mid-term survival and results are favourable. However, the analysed factors in this study that predict reduced survival (high preoperative creatinine, low haemoglobin, low ejection fraction and larger aneurysms) should be judged when planning endovascular repair of AAA.
Collapse
|
28
|
Barry IP, Barns M, Verhoeven E, Wong J, Dubenec S, Heyligers JM, Milner R, Shutze WP, Bachoo P, Vlaskovky P, Mwipatayi BP. Excluder Stent Graft-Related Outcomes in Patients with Aortic Neck Anatomy Outside of Instructions For Use (IFU) within the Global Registry for Endovascular Aortic Treatment (GREAT): Mid-term Follow-Up Results. Ann Vasc Surg 2021; 76:222-231. [PMID: 34182115 DOI: 10.1016/j.avsg.2021.04.032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2020] [Revised: 04/12/2021] [Accepted: 04/13/2021] [Indexed: 10/21/2022]
Abstract
BACKGROUND The utilisation rate of endovascular aortic aneurysm repair has increased continuously over the past 2 decades. Endovascular aortic aneurysm repair is still performed frequently in patients with an unfavourable proximal seal zone, despite the associated late complications. PURPOSE We aimed to evaluate the mid-term durability of the GORE® EXCLUDER® AAA Endoprosthesis, featuring the C3 delivery system, in patients with a proximal neck anatomy outside the instructions for use (IFU). METHODS A retrospective sub-analysis of the Global Registry for Endovascular Aortic Treatment including patients treated for abdominal aortic aneurysms with the GORE EXCLUDER AAA Endoprosthesis (W.L. Gore & Associates, Inc, Flagstaff, Arizona) was performed. A "challenging neck" was defined as those treated outside the IFU with an aortic neck length <15 mm and/or aortic neck angle >60°. Cox proportional analyses were used to test for time-to-event differences between those treated within and outside the IFU while accounting for covariates, specifically proximal neck length and neck angle. The main outcomes assessed were 5-year all-cause mortality, 5-year endoleak development (type I or III), and 5-year device-related reinterventions. FINDINGS Of the 3,324 patients included in the analysis, 411 (12.4%) had a challenging neck and 2,913 (87.6%) did not. The patients in the challenging neck group were significantly older (74.9 years vs. 73.2 years, p≤0.0001) and had a significantly larger aortic aneurysm diameter at the time of the intervention than those treated within the IFU (61.2 mm vs. 56.4 mm, P< 0.0001), shorter proximal neck length (18 mm vs. 30 mm, P< 0.0001) and larger infrarenal neck angle (60.8° vs. 25.8°, P< 0.0001). In the multivariate analysis, brachial access site and challenging neck were not independent risk factors; increased age was associated with a shorter time to mortality (hazard ratio 1.051, 95% confidence interval 1.039-1.062, P< 0.0001), as was the use of tobacco (hazard ratio 1.329, 95% confidence interval 1.124-1.571, P= 0.0009). The 5-year all-cause mortality (36.2% vs. 27.5%, P= 0.002) and aorta-related mortality (3.8% vs. 1.1%, P= 0.002) were significantly higher in the challenging neck group. The risk of death within 5 years also increased significantly at 1.1% per millimetre increase in the abdominal aortic aneurysm diameter (P= 0.0005). Furthermore, the rates of type Ia endoleak development (7% vs. 1.2%, P< 0.001) and requirement for reintervention (13.3% vs. 9.7%, P< 0.001) were higher in those treated outside the IFU (challenging neck group). CONCLUSIONS Treatment with the Excluder AAA Endograft outside the IFU was associated with higher 5-year mortality values, increased type Ia endoleak development rates, and a greater need for reintervention compared with treatment within the IFU. This reiterates that fenestrated and open treatments should be strongly considered in cases with aortic neck anatomies outside the IFU. Infrarenal endovascular intervention outside the IFU should only be used when there is no alternative, with meticulous procedural planning and intervention to promote satisfactory outcomes.
Collapse
Affiliation(s)
- Ian P Barry
- Department of Vascular Surgery, Royal Perth Hospital, Perth, Australia
| | - Mitchell Barns
- Department of Vascular Surgery, Royal Perth Hospital, Perth, Australia
| | - Eric Verhoeven
- Department of Vascular and Endovascular Surgery, General Hospital and Paracelsus Medical University, Nuremberg, Germany
| | - Jackie Wong
- Department of Vascular Surgery, Royal Perth Hospital, Perth, Australia
| | - Steven Dubenec
- Department of Vascular Surgery, Royal Prince Alfred, Sydney, Australia
| | - Jan Mm Heyligers
- Department of Vascular Surgery, Elisabeth TweeSteden Hospital, Tilburg, The Netherlands
| | - Ross Milner
- Division of Vascular Surgery and Endovascular Therapy, University of Chicago Medicine, Chicago, IL
| | - William P Shutze
- Division of Vascular Surgery, The Heart Hospital Baylor, Plano, TX
| | - Paul Bachoo
- Department of Vascular and Endovascular Surgery, Aberdeen Royal Infirmary, Aberdeen, UK
| | - Philip Vlaskovky
- Royal Perth Hospital and School of Medicine, University of Western Australia, Perth, Australia
| | - Bibombe P Mwipatayi
- Department of Vascular Surgery, Royal Perth Hospital, Perth, Australia; School of Surgery, Faculty of Medicine, Dentistry and Health Sciences, University of Western Australia, Perth, Australia.
| | | |
Collapse
|
29
|
de Donato G, Pasqui E, Panzano C, Brancaccio B, Grottola G, Galzerano G, Benevento D, Palasciano G. The Polymer-Based Technology in the Endovascular Treatment of Abdominal Aortic Aneurysms. Polymers (Basel) 2021; 13:polym13081196. [PMID: 33917214 PMCID: PMC8068055 DOI: 10.3390/polym13081196] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Revised: 04/02/2021] [Accepted: 04/04/2021] [Indexed: 12/18/2022] Open
Abstract
An abdominal aortic aneurysm (AAA) is a dilatation of the abdominal aorta that progressively grows until it ruptures. Treatment is typically recommended when the diameter is more than 5 cm. The EVAR (Endovascular aneurysm repair) is a minimally invasive procedure that involves the placement of an expandable stent graft within the aorta to treat aortic disease without operating directly on the aorta. For years, stent grafts' essential design was based on metallic stent frames to support the fabric. More recently, a polymer-based technology has been proposed as an alternative method to seal AAA. This review underlines the two platforms that are based on a polymer technology: (1) the polymer-filled endobags, also known as Endovascular Aneurysm Sealing (EVAS) with Nellix stent graft; and (2) the O-ring EVAR polymer-based proximal neck sealing device, also known as an Ovation stent graft. Polymer characteristics for this particular aim, clinical applications, and durability results are hereby summarized and commented critically. The technique of inflating endobags filled with polymer to exclude the aneurysmal sac was not successful due to the lack of an adequate proximal fixation. The platform that used polymer to create a circumferential sealing of the aneurysmal neck has proven safe and effective.
Collapse
|
30
|
Morphological applicability of currently available stent grafts in the endovascular repair of asymptomatic abdominal aortic aneurysm in East-Central European patients. ADVANCES IN INTERVENTIONAL CARDIOLOGY 2021; 17:93-100. [PMID: 33868423 PMCID: PMC8039927 DOI: 10.5114/aic.2021.104774] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Accepted: 12/16/2020] [Indexed: 11/17/2022] Open
Abstract
Introduction Currently, there is a wide range of commercially available devices for endovascular aneurysm repair (EVAR) that differ in terms of both anatomical requirements and the technology and technique of deployment. Aim To assess the applicability of currently commercially available devices for EVAR in the treatment of an asymptomatic abdominal aneurysm (AAA). Material and methods The study group included 100 patients with infrarenal AAA with a maximum diameter ≥ 50 mm, qualified for invasive treatment at the University Hospital in 2013–2014. The aortoiliac morphological characteristics of the AAA were evaluated on preoperative computed tomography angiograms using the OsiriX DICOM viewer in the 3D-MPR mode. The morphological applicability of 14 types of CE-marked and FDA-approved stent grafts was determined based on their instructions for use (IFU). Results EVAR was feasible with at least one of the analysed devices in 68% of patients. The morphological applicability was as follows: Excluder Conformable (65%), Ovation iX (51%), Endurant II (47%), Treo (45%), Excluder C3 (45%), AFX 2 (45%), Incraft (44%), E-tegra (44%), Zenith Alfa (41%), Zenith Flex (40%), Anaconda (39%) Aorfix (37%), Altura (34%), and E-vita (20%). The differences in the stent graft applicability were statistically significant (p < 0.001). A wide diameter of the common iliac artery, angulated proximal neck, and diameter of proximal neck out of range constituted the most frequent causes of EVAR inapplicability. Conclusions The IFU-based applicability of currently available AAA stent graft systems differs significantly. Despite the constant evolution of EVAR technology, at least 32% of AAA will require a different therapeutic approach.
Collapse
|
31
|
Finotello A, Schuurmann R, Di Gregorio S, Boschetti GA, Chakfé N, Pane B, Spinella G, de Vries JP, Palombo D, Pratesi G. Initial Clinical Experience With a New Conformable Abdominal Aortic Endograft: Aortic Neck Coverage and Curvature Analysis in Challenging Aortic Necks. J Endovasc Ther 2021; 28:407-414. [PMID: 33660576 DOI: 10.1177/1526602821996723] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
OBJECTIVES Aim of this work was to investigate precision of deployment and conformability of a new generation GORE EXCLUDER Conformable Endoprosthesis with active control system (CEXC Device, W.L. Gore and Associates, Flagstaff, AZ, USA) by analyzing aortic neck coverage and curvature. METHODS All consecutive elective patients affected by abdominal aortic aneurysm or aortoiliac aneurysm treated at our institution between November 2018 and June 2019 with the new CEXC Device were enrolled. Validated software was adopted to determine the available apposition surface area into the aortic neck, apposition of the endograft to the aortic wall, shortest apposition length (SAL), shortest distance between the endograft fabric and the lowest renal arteries (SFD) and between the endograft fabric and the contralateral renal artery (CFD). Pointwise centerline curvature was also computed. RESULTS Twelve patients (10 men, median age 78 years (71.75, 81.0)) with available pre- and postoperative computed tomography angiography (CTA) were included. Technical success was obtained in all the cases. Preoperative median length of the proximal aortic neck was 16.1 mm (10.7, 21.7) and suprarenal (α) and infrarenal (β) neck angulation were, respectively, 28.9° (15.7°, 47.5°) and 75.0° (66.9°, 81.4°). Postoperative median apposition surface coverage was 79% (69.25%, 90.75%) of the available apposition surface. SFD and CFD were 1.5 mm (0.75, 5.25) and 7 mm (4.5, 21.5), respectively. Average curvature over the infrarenal aorta decreased from 25 m-1 (21.75, 29.0) to 22.5 m-1 (18.75, 24.5) postoperatively (p=0.02). Maximum curvature did not decrease significantly from 64.5 m-1 (54.25, 92.0) to 62 m-1 (41.75, 71.5) (p=0.1). CONCLUSIONS Our early experience showed that deployment of the CEXC Device is safe and effective for patients with challenging proximal aortic necks. Absence of significant changes between pre- and postoperative proximal aortic neck angulations and curvature confirms the high conformability of this endograft.
Collapse
Affiliation(s)
- Alice Finotello
- Clinic of Vascular and Endovascular Surgery, Ospedale Policlinico San Martino, Department of Integrated Surgical and Diagnostic Sciences, University of Genoa, Italy
| | - Richte Schuurmann
- Department of Surgery, Division of Vascular Surgery, University Medical Center Groningen, the Netherlands
| | - Sara Di Gregorio
- Clinic of Vascular and Endovascular Surgery, Ospedale Policlinico San Martino, Department of Integrated Surgical and Diagnostic Sciences, University of Genoa, Italy
| | - Gian Antonio Boschetti
- Clinic of Vascular and Endovascular Surgery, Ospedale Policlinico San Martino, Department of Integrated Surgical and Diagnostic Sciences, University of Genoa, Italy
| | - Nabil Chakfé
- Department of Vascular Surgery and Kidney Transplantation, University Hospital of Strasbourg, France.,GEPROVAS, Strasbourg, France
| | - Bianca Pane
- Clinic of Vascular and Endovascular Surgery, Ospedale Policlinico San Martino, Department of Integrated Surgical and Diagnostic Sciences, University of Genoa, Italy
| | - Giovanni Spinella
- Clinic of Vascular and Endovascular Surgery, Ospedale Policlinico San Martino, Department of Integrated Surgical and Diagnostic Sciences, University of Genoa, Italy
| | - Jean-Paul de Vries
- Department of Surgery, Division of Vascular Surgery, University Medical Center Groningen, the Netherlands
| | - Domenico Palombo
- Clinic of Vascular and Endovascular Surgery, Ospedale Policlinico San Martino, Department of Integrated Surgical and Diagnostic Sciences, University of Genoa, Italy
| | - Giovanni Pratesi
- Clinic of Vascular and Endovascular Surgery, Ospedale Policlinico San Martino, Department of Integrated Surgical and Diagnostic Sciences, University of Genoa, Italy
| |
Collapse
|
32
|
Salemans PB, Lind RC, van der Linde RA, Pierie MP, Fritschy WM. Up to 10-year follow-up after EVAR with the Endurant stent graft system: a single-center experience. THE JOURNAL OF CARDIOVASCULAR SURGERY 2021; 62:242-249. [PMID: 33635041 DOI: 10.23736/s0021-9509.21.11643-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Endovascular aneurysm repair (EVAR) has become the preferred treatment for infrarenal abdominal aortic aneurysms (AAA) over open surgical repair. The Endurant stent graft is widely used, and large registries report low rates of aneurysm-related mortality and reinterventions at midterm follow-up. Reports of long-term follow-up are limited. The aim of this study is to report our experiences and share our results, reintervention rate and mortality at long-term follow-up after using the Endurant stent graft. METHODS All consecutive patients treated between 2009 and 2013 with the Medtronic Endurant I and II stent graft for an infrarenal AAA in an elective setting were included. Primary outcomes were overall and aneurysm-related survival and reintervention rates. RESULTS One hundred sixty-five consecutive patients (median age 74; IQR: 68-79) with an aneurysm diameter of 62 mm (IQR: 58-70) and neck length of 29 mm (IQR: 21-40) were electively treated with the Endurant I or II stent graft. One hundred thirty-four patients (81.2%) were treated inside IFU (instructions for use) and 31 (18.8%) outside IFU. At median follow-up of 76 months (IQR: 50-97), 60 patients (36.4%) were deceased. Kaplan-Meier estimates at 10 years follow-up of overall survival and freedom from aneurysm-related mortality were respectively 48.5% (CI: 43.7-53.3%) and 97.3% (CI: 95.7-98.9%). Freedom from reintervention was 86.0% with an CI: 83.1-88.9% at 5 years follow-up and 75.6% with a CI: 70.2-81.0% at 10 years follow-up. A total of 25 (15.2%) patients had an EVAR-related reintervention; indications were endoleak (EL) type 1A (N.=11), EL type 1B (N.=3), EL type 2 (N.=6), EL type 3 (N.=1) and limb occlusion (N.=4). We found no significant differences in outcome between the inside and outside IFU groups. At 5 years follow-up 92.6% of patients had stable or decreased diameter, and 7.4% had an increased diameter. CONCLUSIONS This large cohort single-center study demonstrates the effectiveness and safety of the Endurant stent graft system at long-term follow-up with low reintervention rates and aneurysm-related mortality.
Collapse
Affiliation(s)
| | - Robert C Lind
- Department of Thoracic and Vascular Surgery, Linköping University Hospital, Linköping, Sweden
| | | | | | | |
Collapse
|
33
|
Unilateral Embolization of the Internal Iliac Artery for Endovascular Aortic Repair Does Not Induce Gluteal Muscle Atrophy. Ann Vasc Surg 2020; 73:361-368. [PMID: 33359705 DOI: 10.1016/j.avsg.2020.10.050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2020] [Revised: 10/26/2020] [Accepted: 10/31/2020] [Indexed: 11/20/2022]
Abstract
BACKGROUND To investigate the effect of unilateral internal iliac artery (IIA) embolization for endovascular aortic repair (EVAR) on gluteal muscle size. METHODS We assessed the gluteal muscle size in 111 consecutive patients who underwent elective EVAR with unilateral IIA embolization (n = 31) or without IIA embolization (n = 80) for abdominal aortic and/or iliac artery aneurysm. The cross-sectional area (CSA) of the gluteus maximus (Gmax) and gluteus medius/minimus (Gmed/min) was measured on computed tomography preoperatively, 6 months postoperatively, and final follow-up. Mean changes in the Gmax and Gmed/min CSA were evaluated using a mixed model analysis of variance. RESULTS In the patients with embolization, both the Gmax and Gmed/min CSA significantly decreased over time on the embolization and nonembolization sides (P < 0.001); however, embolization did not affect the changes in the Gmax CSA (P = 0.64) and Gmed/min CSA (P = 0.99). In the patients with embolization and those without embolization, both the Gmax and Gmed/min CSA significantly decreased over time (P < 0.001); however, embolization did not affect the changes in the Gmax CSA (P = 0.76) and Gmed/min CSA (P = 0.11). CONCLUSIONS Unilateral IIA embolization was not associated with gluteal muscle atrophy after EVAR. Pre-emptive unilateral IIA embolization for EVAR seems to be an acceptable procedure in terms of maintenance of gluteal muscle size.
Collapse
|
34
|
Spanos K, Behrendt CA, Kouvelos G, Giannoukas AD, Kölbel T. A new randomized controlled trial on abdominal aortic aneurysm repair is needed. J Vasc Surg 2020; 72:2145-2148. [DOI: 10.1016/j.jvs.2020.06.102] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2020] [Accepted: 06/05/2020] [Indexed: 12/22/2022]
|
35
|
Eagleton MJ, Stoner M, Henretta J, Dryjski M, Panneton J, Tassiopoulos A, Mehta M, Pearce B, Sharafuddin MJ. Safety and effectiveness of the TREO stent graft for the endovascular treatment of abdominal aortic aneurysms. J Vasc Surg 2020; 74:114-123.e3. [PMID: 33253871 DOI: 10.1016/j.jvs.2020.10.083] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Accepted: 10/25/2020] [Indexed: 12/19/2022]
Abstract
OBJECTIVE The short- and mid-term outcomes of endovascular aortic aneurysm repair have made it a standard treatment of abdominal aortic aneurysms. However, newer generation devices have yet to demonstrate improved long-term rates for complications, reinterventions, and survival. The TREO stent graft is a latest generation device and was evaluated for approval in the United States. METHODS In a multicenter, nonrandomized, investigational device exemption clinical trial, we assessed the safety and effectiveness of the TREO device, with core laboratory assessment of the imaging studies and an independent adjudication of safety. The primary effectiveness endpoint was successful aneurysm treatment at 1 year. The primary safety endpoint was the incidence of major adverse events (MAE) at 30 days. RESULTS A total of 150 patients (132 men; 88.0%) with infrarenal abdominal aortic (87.3%) or aortoiliac (12.7%) aneurysms were enrolled. The data were normally distributed. The mean age was 71.7 ± 7.4 years. The MAE incidence at 30 days was 0.7%. One subject experienced two MAE: myocardial infarction and procedural blood loss of 1000 mL. The proportion of successful aneurysm treatment at 1 year was 93.1%. Longer term follow-up continues, with no aneurysm-related mortality at the latest follow-up. At 3 years, the cumulative all-cause mortality and incidence of type I and type III endoleaks was 10.7% (n = 16), 2.7% (n = 4), and 0% (n = 0), respectively. In addition, aneurysm sac shrinkage >5 mm at 3 years had occurred in 54.3% of patients, and 9.3% had required a secondary intervention (n = 14). CONCLUSIONS The safety and effectiveness of endovascular repair of abdominal aneurysms with TREO were demonstrated, with 93.1% successful aneurysm treatment at 1 year and aneurysm sac shrinkage >5 mm at 3 years in 54.3% of patients. Long-term follow-up continues to determine whether these favorable outcomes will be sustained.
Collapse
Affiliation(s)
- Matthew J Eagleton
- Division of Vascular and Endovascular Surgery, Fireman Vascular Center, Massachusetts General Hospital, Boston, Mass
| | - Michael Stoner
- Division of Vascular Surgery, University of Rochester Medical Center, Rochester, NY.
| | - John Henretta
- Department of Vascular Surgery, Mission Hospital, Asheville, NC
| | - Maciej Dryjski
- Department of Surgery, Buffalo General Medical Center, Buffalo, NY
| | - Jean Panneton
- Department of Vascular Surgery, Eastern Virginia Medical School, Norfolk, Va
| | | | - Manish Mehta
- Department of Vascular Surgery, Vascular Health Partners of Community Care Physicians, PC, Latham, NY
| | - Benjamin Pearce
- Vascular Surgery and Endovascular Therapy, University of Alabama at Birmingham, Birmingham, Ala
| | | | | |
Collapse
|
36
|
Meisenbacher K, Hagedorn M, Grond-Ginsbach C, Weber D, Böckler D, Bischoff MS. Outcomes of thoracic endovascular aortic repair in thoracic aortic aneurysm and penetrating aortic ulcer using the Conformable Gore TAG within and outside the instructions for use. Vascular 2020; 29:486-498. [PMID: 33131466 DOI: 10.1177/1708538120970033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
OBJECTIVE To describe the outcome of thoracic endovascular aortic repair (TEVAR) in thoracic aortic aneurysm and penetrating aortic ulcer with respect to instructions for use status. METHODS Between October 2009 and September 2017, a total of 532 patients underwent TEVAR; of which 195 have been treated using the Conformable GORE® TAG® thoracic endoprosthesis (CTAG). Fifty-six patients of this cohort underwent TEVAR for thoracic aortic aneurysm/penetrating aortic ulcer using the CTAG. Depending on the preoperative computed tomography angiography findings, patients were classified as inside or outside the device's instructions for use. All inside instruction for use patients underwent postoperative reclassification regarding the instructions for use status. Study endpoints included TEVAR-related reintervention, exclusion of the pathology (endoleak type I/III), TEVAR-related mortality, and graft-related serious adverse events. The median duration of follow-up was 29.7 months (range: 0-109.4 months). RESULTS Of the 56 patients, 17 were primarily classified as outside instruction for use, and in additional 13 patients, TEVAR was performed outside instruction for use, leading to 30 outside instruction for use patients (53.6%). Twenty-six patients (46.4%) were treated inside instruction for use. Reintervention-free survival was lower in outside instruction for use patients (P = 0.016) with a hazard ratio of 9.74 (confidence interval 1.2-80.2; P = 0.034) for TEVAR-related reintervention. With respect to endoleak type I/III, relevant difference was detected between inside/outside instruction for use status (P = 0.012). The serious adverse event rate was 30.4%, mainly in outside instruction for use patients (P = 0.004). Logistic regression analysis indicated an association between graft-related serious adverse event/instructions for use status (odds ratio 6.11; confidence interval 1.6-30.06; P = 0.012). In-hospital death was seen more frequently in outside instruction for use patients (P = 0.12) as was procedure-related death (log-rank test: P = 0.21). CONCLUSION TEVAR for thoracic aortic aneurysm/penetrating aortic ulcer is frequently performed outside instruction for use despite preoperative inside instruction for use eligibility, leading to important consequences for technical/clinical outcome. Instructions for use adherence in TEVAR should be of interest for further large-scale studies.
Collapse
Affiliation(s)
- Katrin Meisenbacher
- Department of Vascular and Endovascular Surgery, Heidelberg University Hospital, Germany
| | - Matthias Hagedorn
- Department of Vascular and Endovascular Surgery, Heidelberg University Hospital, Germany
| | - Caspar Grond-Ginsbach
- Department of Vascular and Endovascular Surgery, Heidelberg University Hospital, Germany
| | - Dorothea Weber
- Institute of Medical Biometry and Informatics, University of Heidelberg, Heidelberg, Germany
| | - Dittmar Böckler
- Department of Vascular and Endovascular Surgery, Heidelberg University Hospital, Germany
| | - Moritz S Bischoff
- Department of Vascular and Endovascular Surgery, Heidelberg University Hospital, Germany
| |
Collapse
|
37
|
Becquemin JP, Haupert S, Issam F, Dubar A, Martelloni Y, Jousset Y, Sauguet A. Five Year Patient Outcomes of Endovascular Abdominal Aortic Aneurysm Repair in the ENDURANT France Registry. Eur J Vasc Endovasc Surg 2020; 61:98-105. [PMID: 33004284 DOI: 10.1016/j.ejvs.2020.08.034] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2020] [Revised: 08/06/2020] [Accepted: 08/20/2020] [Indexed: 01/01/2023]
Abstract
OBJECTIVE Endovascular repair is the preferred method of treatment for infrarenal abdominal aortic aneurysms with numerous publications from multiple geographic regions showing excellent patient outcomes. Since the original ACE (Anevrysme de l'aorte abdominale: Chirurgie versus Endoprothese) randomised control trial, studies of French specific population have also contributed significantly to the body of evidence in support of endovascular abdominal aortic repair. METHODS In the ENDURANT France registry, 180 patients were consecutively enrolled from 20 French centres starting in 2012. Investigational sites included public and private practice and differing centre volumes to be as representative of real world French experience as possible. The aim of this study was to present the five year outcomes from this registry. RESULTS Instructions for use (IFU) were respected in 97.8% (176/180) of patients. At five years, the Kaplan-Meier overall survival was 69.9% ± 3.5% and the freedom from aneurysm related death was 97.6% ± 1.2%. The freedom from Type IA endoleaks was 94.5% ± 1.7%, freedom from endoleaks of any type was 70.1 ± 3.4%, and freedom from secondary endovascular procedure 90.4% ± 2.6%. In addition, 61.6% (45/73) of patients exhibited sac shrinkage at five years. CONCLUSION In this five year report of the Endurant France registry, survival, re-intervention, and freedom from endoleak rates were comparable to recent EVAR registries and there was a high sac shrinkage rate. Secondary procedure and aneurysm rupture were lower than those of ACE, the French RCT which included older generation devices. This prospective registry demonstrates favourable five year outcomes of the Endurant stent graft used within IFU.
Collapse
Affiliation(s)
- Jean-Pierre Becquemin
- Institut Vasculaire Paris Est, Hopital Privé Paul d'Egine, Ramsay Group Champigny, France.
| | | | - Farah Issam
- Clinique Belledonne, Saint Martin d'Hères, France
| | | | | | | | | |
Collapse
|
38
|
Georgiadis GS, Chatzigakis PK, Kouvelos G, Argyriou C, Kopadis GC, Georgakarakos EI, Matsagkas M. Multicenter Mid-term Results After Endovascular Aortic Aneurysm Repair with the Incraft® Device. Ann Vasc Surg 2020; 72:464-478. [PMID: 32946999 DOI: 10.1016/j.avsg.2020.09.018] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2020] [Revised: 09/05/2020] [Accepted: 09/08/2020] [Indexed: 12/20/2022]
Abstract
OBJECTIVES Durability after endovascular aortic aneurysm repair (EVAR) is considered an ongoing topic of investigation and was always a point of concern with smaller profile devices. Recently released five-year clinical trial results using the Incraft® ultralow profile device are encouraging. However, additional real-life experience will need to assist these initial findings. Herein, we investigated the outcomes after EVAR, in real world practice using the Incraft® endograft (EG). MATERIAL AND METHODS Seventy-seven patients with infrarenal abdominal aortic aneurysms (AAA) ≥50 mm in diameter treated with the Incraft® device in three vascular centers were enrolled from November 2015 to July 2018. Follow-up was completed in August 2020. Selection of EVAR using the Incraft® device was individualized according to aorto-iliac morphologic features, comorbidities, history of previous abdominal surgery and preference of the patient. At the early phase of the study, we specifically opted for preferential use of this low profile EG mainly in cases of small and tortuous iliac vessels (more challenging access routes). At later stages, it was used according to surgeon preference and not specifically in complex anatomies (real-world conditions). End-points included technical success, perioperative complications, 30-day survival, endoleg patency, presence of endoleaks, sac enlargement >5 mm and clinical success. RESULTS The primary technical success rate was 97.4% before the addition of an aortic cuff and iliac extension for a type Ia and type Ib endoleak respectively, and the repair of a maldeployment iliac component (primary-assisted and secondary technical success, 100%). Intraoperative small type II endoleaks (visible in final angiogram) were noted in 19 patients (24.7%). There were no intraoperative deaths from AAA rupture, primary conversions or conversions to aortounilateral grafts. Two complications occurred, necessitating hybrid techniques for repair (replaced of a dislodged endoleg and distal external iliac artery hemostasis). No deaths were reported within 30 days. Occlusion of an endoleg, was observed in two patients, 6 and 14 months respectively after implantation (2.6%), and were treated by femoral-femoral PTFE bypass after unsuccessful endovascular recanalization. The latter required open conversion, 3 mo later, to repair compromised flow to the inflow iliac axis. Three patients (3.9%) experienced sac enlargement >5 mm in diameter compared with the 1-month CT scan. All of these had type II endoleaks and two received embolization procedures. Eleven patients died from causes unrelated to AAA repair. Clinical success was 97.3%, 92.8% and 89.4% through 1, 2 and 3 years respectively. CONCLUSIONS EVAR with the Incraft® device might be considered a reliable option in real-world conditions and not specifically only in complex iliac anatomies.
Collapse
Affiliation(s)
- George S Georgiadis
- Department of Vascular Surgery, "Democritus" University of Thrace, University General Hospital of Alexandroupolis, Alexandroupolis, Greece.
| | - Petros K Chatzigakis
- Department of Vascular Surgery, Gennimatas General Hospital of Athens, Athens, Greece
| | - George Kouvelos
- Department of Vascular Surgery, University of Thessaly, Larissa, Greece
| | - Christos Argyriou
- Department of Vascular Surgery, "Democritus" University of Thrace, University General Hospital of Alexandroupolis, Alexandroupolis, Greece
| | - Georgios C Kopadis
- Department of Vascular Surgery, Gennimatas General Hospital of Athens, Athens, Greece
| | - Efstratios I Georgakarakos
- Department of Vascular Surgery, "Democritus" University of Thrace, University General Hospital of Alexandroupolis, Alexandroupolis, Greece
| | | |
Collapse
|
39
|
Benveniste GL, Tjahjono R, Chen O, Verhagen HJ, Böckler D, Varcoe RL. Long-term Results of 180 Consecutive Patients with Abdominal Aortic Aneurysm Treated with the Endurant Stent Graft System. Ann Vasc Surg 2020; 67:265-273. [DOI: 10.1016/j.avsg.2020.02.020] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2019] [Revised: 02/04/2020] [Accepted: 02/16/2020] [Indexed: 10/24/2022]
|
40
|
Holden A, Hill A. Endoluminal Management of Infra-renal Aortic and Aorto-iliac Aneurysms. Cardiovasc Intervent Radiol 2020; 43:1788-1797. [PMID: 32566971 DOI: 10.1007/s00270-020-02563-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Accepted: 06/10/2020] [Indexed: 12/19/2022]
Abstract
This paper reviews the development of endovascular aneurysm repair (EVAR) of infra-renal aortic and iliac artery aneurysms and considers the current status and best treatment options. The vast majority of devices are bifurcated and exclude the aneurysm utilizing the same techniques for fixation and seal. The modern EVAR procedure is usually performed in a hybrid operating theatre, utilizing image fusion and other radiation-reducing techniques and using optimized procedural techniques, including percutaneous access. The best outcomes are achieved in patients whose anatomy is within device "instructions for use", but these are most commonly breached due to "hostile" neck anatomy. Endovascular options for these cases include the use of fenestrated endografts, chimney grafts and endoanchors. Concomitant iliac artery aneurysms often occur with abdominal aortic aneurysms, and endovascular options include limb extensions with internal iliac embolization as well as iliac branch devices. The durability of EVAR has recently been called into question by long-term results from early EVAR randomized trial. Findings such as infra-renal neck dilatation and aneurysm sac expansion are relatively common and associated with adverse outcomes. This durability concern mandates regular and long-term imaging and clinical surveillance. It also indicates that EVAR technology is not fully evolved with a need for further development to improve patient applicability and long-term durability.
Collapse
|
41
|
Reyes Valdivia A, Duque Santos Á, Pitoulias G, Aracil Sanus E, Ocaña Guaita J, Gandarias Zúñiga C. Predictors of inadequate EndoAnchors aortic wall penetration for the Endosutured therapy in hostile neck patients. THE JOURNAL OF CARDIOVASCULAR SURGERY 2020; 61:738-744. [PMID: 32558525 DOI: 10.23736/s0021-9509.20.11248-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND The use of EndoAnchors is increasing; however, not much about appropriate use in terms of aortic wall penetration (AWP) is described. We aim to evaluate the procedural and anatomical conditions related with borderline (b) or absence (ab) of AWP when checked on first CT-scan after the Endosutured aortic repair (ESAR) for hostile neck anatomies (HNA). METHODS This study with NCT04100499 is a single center prospective evaluation of patients receiving EndoAnchors for prevention or treatment of a proximal EVAR failure. AWP was evaluated on first CT-scan and findings correlated with neck anatomical features and procedural data. The sum of borderline and absence of AWP was considered as Inadequate - In-AWP (failure). Adjunctive procedures, reinterventions, all-cause mortality, absence of type Ia EL and aneurysm related mortality are also described. RESULTS Forty-eight patients were treated during the study period and 43 high-surgical risk patients were finally included in the study for analysis with at least one HNA criteria (58%) and associating two in 21% or even three in 21%. A total of 250 EndoAnchors were deployed at a median 6 (range, 4-10) per case. From those, 31 (12.5%) achieved b-AWP and 11 (4.4%) ab-AWP, meaning 42 (16.8%) EndoAnchors with In-AWP. Univariate-analysis showed being an occasional user and a therapeutic case as predictor for at least one and more failures. The only predictor on multivariate analysis for two or more EndoAnchors with In-AWP was being an occasional user. Cumulative-survival and freedom from type-Ia EL at 2-years was 84% and 95%; respectively. CONCLUSIONS Outcomes of the ESAR therapy should be validated according to their aortic wall penetration checked on first CT-scan. EndoAnchors use in HNA should not be considered an easy approach for the endovascular technique, especially for therapeutic cases. An individual and specific case analysis counterbalancing inadequate use of the device in unexperienced users should be evaluated against the increased risk of proximal failure as in standard EVAR alone during HNA treatment.
Collapse
Affiliation(s)
- Andrés Reyes Valdivia
- Department of Vascular and Endovascular Surgery, Ramón y Cajal University Hospital, Madrid, Spain -
| | - África Duque Santos
- Department of Vascular and Endovascular Surgery, Ramón y Cajal University Hospital, Madrid, Spain
| | - Georgios Pitoulias
- Faculty of Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece.,Division of Vascular Surgery, Second Department of Surgery, G. Gennimatas Thessaloniki General Hospital, Thessaloniki, Greece
| | - Enrique Aracil Sanus
- Department of Vascular and Endovascular Surgery, Ramón y Cajal University Hospital, Madrid, Spain
| | - Julia Ocaña Guaita
- Department of Vascular and Endovascular Surgery, Ramón y Cajal University Hospital, Madrid, Spain
| | - Claudio Gandarias Zúñiga
- Department of Vascular and Endovascular Surgery, Ramón y Cajal University Hospital, Madrid, Spain
| |
Collapse
|
42
|
Tigkiropoulos K, Stavridis K, Lazaridis I, Bontinis E, Zournatzi I, Kolaki N, Karamanos D, Saratzis N. Outcomes of Endovascular Aneurysm Repair Using the Anaconda Stent-Graft. J Endovasc Ther 2020; 27:462-467. [PMID: 32517558 DOI: 10.1177/1526602820918875] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Purpose: To report outcomes of elective endovascular aneurysm repair (EVAR) using the Anaconda stent-graft in a tertiary vascular center. Materials and Methods: A retrospective study was conducted of 271 patients (mean age 71.5 years; 260 men) who underwent elective EVAR for abdominal aortic aneurysm using the Anaconda stent-graft from January 2006 to January 2017. Median aneurysm diameter was 58 mm (range 50-90). All patients were anatomically suitable for EVAR according to the 2003 version of the instructions for use. Follow-up included computed tomography angiography at 1, 6, and 12 months and yearly thereafter for the first 4 years and then every 2 years. Primary outcomes included technical success and 30-day aneurysm-related mortality and complications; secondary outcomes were overall and aneurysm-related mortality and aneurysm-related morbidity in follow-up. Results: The Anaconda stent-graft was implanted successfully in all patients. Primary and secondary technical success rates were 99.6% and 100%, respectively. Three patients (1.1%) died within 30 days of causes unrelated to the aneurysm, while 15 patients (5.5%) suffered perioperative complications. Median follow-up was 72 months (range 14-141). The overall type I endoleak rate was 4.7% (11 proximal, 2 distal). Late aneurysm-related complications were observed in 48 patients (17.3%); aneurysm-related mortality was 1.4% (n=4). Non-aneurysm-related mortality was 21.0% (n=57). Freedom from reintervention was 95.2% at 1 year, 98% at 2 years, and 90% at 6 years. There was no significant difference in the overall limb graft occlusion rate between the second- and third-generation devices. Conclusion: Results in our cohort study demonstrate that the Anaconda stent-graft has satisfactory early and late results with low aneurysm-related mortality.
Collapse
Affiliation(s)
- Konstantinos Tigkiropoulos
- Vascular Unit, 1st University Surgical Department, Papageorgiou General Hospital, Aristotle University, Thessaloniki, Greece
| | - Kyriakos Stavridis
- Vascular Unit, 1st University Surgical Department, Papageorgiou General Hospital, Aristotle University, Thessaloniki, Greece
| | - Ioannis Lazaridis
- Vascular Unit, 1st University Surgical Department, Papageorgiou General Hospital, Aristotle University, Thessaloniki, Greece
| | - Evangelos Bontinis
- Vascular Unit, 1st University Surgical Department, Papageorgiou General Hospital, Aristotle University, Thessaloniki, Greece
| | - Ioulia Zournatzi
- Vascular Unit, 1st University Surgical Department, Papageorgiou General Hospital, Aristotle University, Thessaloniki, Greece
| | - Nikoletta Kolaki
- Vascular Unit, 1st University Surgical Department, Papageorgiou General Hospital, Aristotle University, Thessaloniki, Greece
| | - Dimitrios Karamanos
- Vascular Unit, 1st University Surgical Department, Papageorgiou General Hospital, Aristotle University, Thessaloniki, Greece
| | - Nikolaos Saratzis
- Vascular Unit, 1st University Surgical Department, Papageorgiou General Hospital, Aristotle University, Thessaloniki, Greece
| |
Collapse
|
43
|
Mwipatayi BP, Oshin OA, Faraj J, Varcoe RL, Wong J, Becquemin JP, Riambau V, Böckler D, Verhagen HJ. Analysis of Midterm Outcomes of Endovascular Aneurysm Repair in Octogenarians From the ENGAGE Registry. J Endovasc Ther 2020; 27:836-844. [PMID: 32436808 DOI: 10.1177/1526602820923827] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE To assess periprocedural results and secondary endovascular procedure outcomes over 5 years in patients aged ≥80 vs <80 years undergoing endovascular aneurysm repair (EVAR). MATERIALS AND METHODS Data from the Endurant Stent Graft Natural Selection Global post-market registry (ENGAGE) were used for the analyses. A total of 1263 consecutive patients were enrolled in the prospective, observational, single-arm registry and divided into 2 groups according to age: ≥80 years (290, 22.9%) and <80 years (973, 77.1%). Baseline patient characteristics, risk scores according to the Society for Vascular Surgery (SVS) reporting standards, American Society of Anesthesiologists (ASA) classification, quality of life assessments [EuroQol 5 (EQ5D) index], and treatment outcomes, including all-cause mortality, aneurysm-related mortality, major adverse events, secondary endovascular procedures, and endoleaks were compared between groups. RESULTS Octogenarians were classified into the highest category of the SVS risk stratification system; however, this did not result in a significant difference in the 30-day mortality [1.4% (4/290) vs 1.2% (12/973) for controls; p=0.85] or major adverse event rates [5.2% (15/290) vs 3.6% (35/973), p=0.23]. Multivariable analysis confirmed that age ≥80 years, pulmonary disease, large aneurysm diameter, and renal insufficiency were significantly associated with all-cause mortality, whereas diameter was the only parameter associated with increased aneurysm-related mortality. The differences in freedom from secondary endovascular procedures over 5 years between octogenarians and controls did not reach statistical significance (88.5% vs 83.2%, p=0.07). CONCLUSION EVAR can be performed in individuals aged ≥80 years with no statistically significant difference in midterm aneurysm-related deaths compared with younger patients. The findings in this elderly patient cohort show that EVAR can be safely performed with acceptable morbidity rates in octogenarians.
Collapse
Affiliation(s)
- Bibombe P Mwipatayi
- Department of Vascular Surgery, Royal Perth Hospital, Perth, Western Australia, Australia.,School of Surgery, Faculty of Medicine, Dentistry and Health Sciences, University of Western Australia, Perth, Western Australia, Australia
| | - Olufemi A Oshin
- Department of Vascular Surgery, Royal Perth Hospital, Perth, Western Australia, Australia
| | - Joseph Faraj
- Department of Vascular Surgery, Royal Perth Hospital, Perth, Western Australia, Australia
| | - Ramon L Varcoe
- Department of Surgery, Prince of Wales Hospital and the University of New South Wales, Sydney, Australia
| | - Jackie Wong
- Department of Vascular Surgery, Royal Perth Hospital, Perth, Western Australia, Australia
| | | | - Vincente Riambau
- Division of Vascular Surgery, Thorax Institute, Hospital Clinic, University of Barcelona, Spain
| | - Dittmar Böckler
- Division of Vascular Surgery, University Hospital Heidelberg, Germany
| | - Hence J Verhagen
- Division of Vascular and Endovascular Surgery, Erasmus University Medical Center, Rotterdam, the Netherlands
| |
Collapse
|
44
|
Endurant stent graft demonstrates promising outcomes in challenging abdominal aortic aneurysm anatomy. J Vasc Surg 2020; 73:69-80. [PMID: 32442605 DOI: 10.1016/j.jvs.2020.04.508] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2019] [Accepted: 04/16/2020] [Indexed: 10/24/2022]
Abstract
OBJECTIVE We aimed to assess the 5-year safety and effectiveness outcomes of patients enrolled in the Endurant Stent Graft Natural Selection Global Post Market Registry (ENGAGE) who were treated outside the approved indications for use (IFU) of the Endurant stent graft. METHODS Our primary outcome measure was 12-month treatment success, defined as successful endograft delivery and deployment and the absence of type I or III endoleak, stent migration or limb occlusion, late conversion, and abdominal aortic aneurysm diameter increase or rupture. Secondary outcome measures included 30-day all-cause mortality, major adverse events, secondary procedures, technical observations, aneurysm-related mortality, and all-cause mortality within 12 months. RESULTS Demographic characteristics of ENGAGE patients treated outside (225 [17.8%]) and within (1038 [82.2%]) the IFUs were similar, except that female patients comprised a much higher percentage of the outside IFU group (19.1% vs 8.7%; P < .001). The outside IFU group presented with lower rates of coronary artery disease and cardiac revascularization and a greater number of symptomatic patients compared with the within IFU group (21.3% vs 15.0%; P = .020). Technical success was achieved in more than 99% of all patients. The outside and within IFU groups showed a comparable and low occurrence of uncorrected type I (0.9% vs 1.2%; P = 1.00) and type III endoleak (0.4% vs 0.3%; P = .54) immediately after device implantation. The 5-year freedom from type IA endoleaks was 89.4% vs 96.7% (P < .0001) for those patients outside and within the IFUs, respectively, although both groups had similar type III endoleaks through 5 years (P = .61). Stent graft limb occlusion estimated overall survival, and freedom from aneurysm-related mortality and endovascular interventions were comparable in both patient groups through the 5-year follow-up. The Kaplan-Meier estimates at 5 years showed a trend for low but increased need for type I or III endoleak correction procedures in the outside IFU group compared with the within IFU group (7.2% vs 5.2%; P = .099). CONCLUSIONS Differences were not observed in all-cause mortality, aneurysm-related mortality, and secondary procedures between within and outside IFU patients through a 5-year follow-up in the ENGAGE registry. Proximal necks with angulation or diameters outside the IFUs were the most common reasons for patients identified as being outside IFU, and the cohort had increased incidence of type IA endoleaks. Despite the challenges presented from the broad range of aortic and abdominal aortic aneurysm morphologies, the Endurant stent graft showed promising 5-year outcomes.
Collapse
|
45
|
Editor's Choice – Systematic Review of the Use of Endoanchors in Endovascular Aortic Aneurysm Repair. Eur J Vasc Endovasc Surg 2020; 59:748-756. [DOI: 10.1016/j.ejvs.2020.02.008] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2019] [Revised: 01/05/2020] [Accepted: 02/10/2020] [Indexed: 11/23/2022]
|
46
|
Sirignano P, Mansour W, Baldassarre V, Porreca CF, Cuozzo S, Miceli F, Capoccia L, Sbarigia E, Speziale F. Infrarenal Abdominal Aortic Aneurysm Endovascular Treatment: Long-term Results From a Single-Center Experience in an Unselected Patient Population. Ann Vasc Surg 2020; 67:274-282. [PMID: 32209404 DOI: 10.1016/j.avsg.2020.03.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2020] [Revised: 03/05/2020] [Accepted: 03/06/2020] [Indexed: 10/24/2022]
Abstract
BACKGROUND The aim of the present study was to evaluate early-, mid-, and long-term outcomes in an unselected population of patients treated for abdominal aortic aneurysms (AAAs) by endovascular aneurysm repair (EVAR) with different commercially available off-the-shelf devices. MATERIALS AND METHODS A retrospective study was conducted on a prospectively compiled computerized database on patients presenting an infrarenal AAA treated between January 2008 and December 2015 in a high-volume Italian tertiary referral Center. Demographic, clinical, and specific morphological features were considered as potentially influencing the outcomes and the type of the implanted device. Outcome measures were procedure-related reintervention, AAA-related, and all-cause mortality rates at 30-day, 12-month, and long-term follow-up. Reinterventions considered for the analysis were AAA rupture, graft infection, type I or III endoleaks, type II endoleaks with sac enlargement > 5 mm, graft stenosis or occlusions, procedures related to renal or visceral ischemia, and reintervention for access vessel injury. RESULTS Of 498 EVAR procedures performed for elective infrarenal AAA treatment during the entire study period, 479 patients were enrolled, the mean age was 73.5 ± 7.34 years (range 51-91), and 416 (86.84%) were men. The mean maximum AAA diameter was 52.02 ± 8.04 mm (range 39-90.2), a maximum AAA diameter ≥59 mm was recorded in 107 patients (22.33%), and an aortic neck length was <10 mm in 137 (28.60%). Technical success was achieved in all patients. At a mean follow-up of 52.97 ± 26.16 months (range 1-120), overall reintervention and death rates were 8.14% and 20.04%, respectively, without AAA-related deaths. At univariate analysis, hypertension was the only demographical variable found to be associated with higher risk of reintervention, P = 0.04 (OR: 2.34; CI 95%: 1.00-5.42). Furthermore, male sex (P = 0.02; OR: 2.62; CI 95%: 1.09-6.27) and chronic renal insufficiency (P = 0.003; OR: 2.08; CI 95%: 1.27-3.42) were associated with higher mortality rates. AAA diameter ≥59 mm was statistically associated with a higher rate of both reintervention and mortality: P < 0.001 (OR: 9.05; CI 95%: 4.52-18.11) and <0.001 (4.00; 2.46-6.49), respectively. CONCLUSIONS Our experience seems to suggest that EVAR could be safely and effectively performed in an unselected patients' population, with encouraging results up to a ten-year follow-up.
Collapse
Affiliation(s)
- Pasqualino Sirignano
- Vascular and Endovascular Surgery Unit, Department of Surgery "Paride Stefanini", Policlinico Umberto I of Rome, "Sapienza" University of Rome, Rome, Italy.
| | - Wassim Mansour
- Vascular and Endovascular Surgery Unit, Department of Surgery "Paride Stefanini", Policlinico Umberto I of Rome, "Sapienza" University of Rome, Rome, Italy
| | - Virgilio Baldassarre
- Vascular and Endovascular Surgery Unit, Department of Surgery "Paride Stefanini", Policlinico Umberto I of Rome, "Sapienza" University of Rome, Rome, Italy
| | - Carlo Filippo Porreca
- Vascular and Endovascular Surgery Unit, Department of Surgery "Paride Stefanini", Policlinico Umberto I of Rome, "Sapienza" University of Rome, Rome, Italy
| | - Simone Cuozzo
- Vascular and Endovascular Surgery Unit, Department of Surgery "Paride Stefanini", Policlinico Umberto I of Rome, "Sapienza" University of Rome, Rome, Italy
| | - Francesca Miceli
- Vascular and Endovascular Surgery Unit, Department of Surgery "Paride Stefanini", Policlinico Umberto I of Rome, "Sapienza" University of Rome, Rome, Italy
| | - Laura Capoccia
- Vascular and Endovascular Surgery Unit, Department of Surgery "Paride Stefanini", Policlinico Umberto I of Rome, "Sapienza" University of Rome, Rome, Italy
| | - Enrico Sbarigia
- Vascular and Endovascular Surgery Unit, Department of Surgery "Paride Stefanini", Policlinico Umberto I of Rome, "Sapienza" University of Rome, Rome, Italy
| | - Francesco Speziale
- Vascular and Endovascular Surgery Unit, Department of Surgery "Paride Stefanini", Policlinico Umberto I of Rome, "Sapienza" University of Rome, Rome, Italy
| |
Collapse
|
47
|
Swerdlow NJ, Lyden SP, Verhagen HJM, Schermerhorn ML. Five-year results of endovascular abdominal aortic aneurysm repair with the Ovation abdominal stent graft. J Vasc Surg 2019; 71:1528-1537.e2. [PMID: 31515176 DOI: 10.1016/j.jvs.2019.06.196] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2019] [Accepted: 06/18/2019] [Indexed: 12/16/2022]
Abstract
OBJECTIVE Endovascular abdominal aortic aneurysm repair (EVAR) has been rigorously compared with open repair for the treatment of abdominal aortic aneurysms in randomized trials and observational studies, but a comparison of individual devices is lacking, and single-device registries and trials are limited by small sample size. Here we report a descriptive analysis of the Effectiveness of Custom Seal with Ovation: Review of the Evidence (ENCORE) database, pooled results of multiple studies evaluating the midterm results of EVAR with the Ovation Abdominal Stent Graft Platform. METHODS This is a retrospective analysis of the ENCORE database, a cohort of patients undergoing EVAR with the Ovation platform composed of pooled, prospectively collected data from 1296 patients from five clinical trials and the prospectively maintained European Union Post-Market Registry. The primary outcomes were 5-year rates of type IA and type I or III endoleak. Secondary outcomes included were 30-day mortality, 30-day major adverse event, technical success (successful deployment of the aortic body and iliac limbs), as well as 5-year survival, and freedom from aneurysm-related mortality, type II endoleak, device-related intervention, aneurysm rupture, sac expansion, and conversion to open repair. RESULTS A total of 1296 patients were included in the analysis. The average age was 73 ± 8 years and 81% of patients were male. Fifty percent of patients had complex aortic anatomy, (neck length <10 mm, neck diameter >28 mm, neck angle >60°, reverse neck taper >10%, distal common iliac artery diameter <10 mm, or external iliac artery diameter <6 mm). Technical success was 99.7%. Thirty-day mortality was 0.3%, 30-day rate of major adverse event was 1.6%, and polymer leak rate was 0.2%. Freedom from type IA endoleak at 1, 3, and 5 years was 97.6%, 97.1%, and 95.8%, respectively; type I or III endoleak at 1, 3, and 5 years was 96.9%, 95.7%, and 94.0%, respectively. Freedom from device-related reintervention at 1, 3, and 5 years was 96.2%, 94.4%, and 92.4% and primary freedom from sac expansion was 97.0% at 1 year, 90.3% at 3 years, and 84.9% at 5 years. Freedom from all-cause mortality and aneurysm-related mortality at 5 years were 78.9% and 99.3%, respectively. CONCLUSIONS This analysis of the ENCORE database demonstrates that EVAR with the Ovation platform has favorable midterm durability evidenced by successful aneurysm exclusion and 5-year freedom from aneurysm-related mortality.
Collapse
Affiliation(s)
- Nicholas J Swerdlow
- Division of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Boston, Mass
| | - Sean P Lyden
- Department of Vascular Surgery, Cleveland Clinic, Cleveland, Ohio
| | - Hence J M Verhagen
- Department of Vascular Surgery, Erasmus University Medical Centre, Rotterdam, The Netherlands
| | - Marc L Schermerhorn
- Division of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Boston, Mass.
| |