1
|
Ali AMBH, Abdel-Aal FAM, Rageh AH, Mohamed AMI. A Comprehensive Review on Analytical Techniques for Determination of Sex Stimulants, PDE5 Inhibitors in Different Matrices with Special Focus on the Electroanalytical Methods. Crit Rev Anal Chem 2022; 54:2023-2052. [PMID: 36508289 DOI: 10.1080/10408347.2022.2152274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Erectile dysfunction (ED) is one of the most common chronic diseases affecting men and its incidence increases with aging. Due to its substantial influence on the quality of life, phosphodiesterase type-5 (PDE5) inhibitors have been implemented to treat ED by increasing the penile blood flow that results in improving erection. PDE5 inhibitors is a class of drugs that affects many pharmacological sectors, and it is essential to review the different analytical methods described for their determination. Few reviews were published concerning this group of drugs. For this reason, this review article gathers the different analytical methods used to determine PDE5 inhibitors in pharmaceutical and biological samples over the past 20 years. Different analytical techniques were used to analyze these compounds in different matrices such as separation methods (capillary electrophoresis, LC-MS, UPLC-MS/MS, and GC-MS), spectroscopic methods (UV-visible methods, FT-IR spectroscopy and spectrofluorometry) and electrochemical methods (polarography, voltammetry and potentiometry). This review focuses on the different electrochemical methods and their use in analytical determination of PDE5 inhibitors in pharmaceutical dosage forms and biological samples. Moreover, it discusses the different modified electrodes used for their electroanalytical determination and the behavior of the studied drugs at different modified electrodes. Additionally, this review discusses the pharmacokinetics of the studied compounds and their interactions with other co-administered drugs especially the metabolic interactions between the studied compounds and other co-administered drugs in different matrices. This literature survey would provide a beneficial guide for future analytical investigation of PDE5 inhibitors.
Collapse
Affiliation(s)
- Al-Montaser Bellah H Ali
- Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Assiut University, Assiut, Egypt
| | - Fatma A M Abdel-Aal
- Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Assiut University, Assiut, Egypt
| | - Azza H Rageh
- Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Assiut University, Assiut, Egypt
| | - Abdel-Maaboud I Mohamed
- Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Assiut University, Assiut, Egypt
| |
Collapse
|
2
|
Hassan AME, El Hamd MA, El-Maghrabey MH, Mahdi WA, Alshehri S, Batakoushy HA. Two Versatile Pencil Graphite-Polymer Sensor Electrodes Coupled with Potentiometry and Potentiometric Titration Methods: Profiling Determinations of Vitamin V in Tablets and Urine Samples. SENSORS (BASEL, SWITZERLAND) 2022; 22:9128. [PMID: 36501827 PMCID: PMC9739328 DOI: 10.3390/s22239128] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Revised: 11/11/2022] [Accepted: 11/22/2022] [Indexed: 06/17/2023]
Abstract
Herein, we developed a new pencil graphite ion-selective electrode strategy for the broadly used erectile dysfunction medication, sildenafil citrate (SC, vitamin V), for its automated potentiometry and potentiometric titration profiling in marketed tablets and human urine samples. The method was based on ion-pair complexation between SC and sodium tetraphenylborate (Na-TPB) or phosphotungstic acid (PTA), embedded into a pencil-fabricated graphite sensor electrode coated with poly(vinyl chloride, PVC) matrix, which is pre-plasticized with two different pre-studied plasticizers. The modern fabricated electrodes have a proven fast near-Nernstian response for SC over the concentration range of 1.0 × 10-6 to 1.0 × 10-2 and 1.0 × 10-5 to 1.0 × 10-2 M, with LODs of 6.5 × 10-7 and 5.5 × 10-6 over a pH 3-6 for (SC-TPB)- and (SC-PTA)-based membrane sensors, of O-nitrophenyl octyl ether (O-NPOE) and dioctyl phthalate (DOP), respectively. The selectivity coefficients for different interferents, including many inorganic cations, sugars, and/or nitrogenous compounds, were tested and confirmed. Applications of the proposed method were conducted on the determination of SC in its tablets and urine samples under the proper conditions. The percent recovery values were compared with those obtained by an official method and showed an RSD ≤ 0.3% (n = 5).
Collapse
Affiliation(s)
- Abeer M. E. Hassan
- Department of Chemistry, Faculty of Pharmacy, 6 October University, 6th of October City 12585, Egypt
| | - Mohamed A. El Hamd
- Department of Pharmaceutical Sciences, College of Pharmacy, Shaqra University, Shaqra 11961, Saudi Arabia
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, South Valley University, Qena 83523, Egypt
| | - Mahmoud H. El-Maghrabey
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Mansoura University, Mansoura 35516, Egypt
| | - Wael A. Mahdi
- Department of Pharmaceutics, College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia
| | - Sultan Alshehri
- Department of Pharmaceutics, College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia
| | - Hany A. Batakoushy
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Menoufia University, Shebin Elkom 32511, Egypt
| |
Collapse
|
3
|
Önal G, Altunkaynak Y, Levent A. Application of BiFE for electrochemical properties and determination of loratadine by cathodic stripping voltammetry in the cationic surfactant medium. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY 2021; 18:3465-3475. [DOI: https:/doi.org/10.1007/s13738-021-02286-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2021] [Accepted: 05/12/2021] [Indexed: 07/01/2024]
|
4
|
da Silveira GD, Bressan LP, Schmidt MEP, Dal Molin TR, Teixeira CA, Poppi RJ, da Silva JAF. Electrochemical behavior of 5-type phosphodiesterase inhibitory drugs in solid state by voltammetry of immobilized microparticles. J Solid State Electrochem 2020. [DOI: 10.1007/s10008-020-04533-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
5
|
Shahbazi MA, Faghfouri L, Ferreira MPA, Figueiredo P, Maleki H, Sefat F, Hirvonen J, Santos HA. The versatile biomedical applications of bismuth-based nanoparticles and composites: therapeutic, diagnostic, biosensing, and regenerative properties. Chem Soc Rev 2020; 49:1253-1321. [PMID: 31998912 DOI: 10.1039/c9cs00283a] [Citation(s) in RCA: 172] [Impact Index Per Article: 43.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Studies of nanosized forms of bismuth (Bi)-containing materials have recently expanded from optical, chemical, electronic, and engineering fields towards biomedicine, as a result of their safety, cost-effective fabrication processes, large surface area, high stability, and high versatility in terms of shape, size, and porosity. Bi, as a nontoxic and inexpensive diamagnetic heavy metal, has been used for the fabrication of various nanoparticles (NPs) with unique structural, physicochemical, and compositional features to combine various properties, such as a favourably high X-ray attenuation coefficient and near-infrared (NIR) absorbance, excellent light-to-heat conversion efficiency, and a long circulation half-life. These features have rendered bismuth-containing nanoparticles (BiNPs) with desirable performance for combined cancer therapy, photothermal and radiation therapy (RT), multimodal imaging, theranostics, drug delivery, biosensing, and tissue engineering. Bismuth oxyhalides (BiOx, where X is Cl, Br or I) and bismuth chalcogenides, including bismuth oxide, bismuth sulfide, bismuth selenide, and bismuth telluride, have been heavily investigated for therapeutic purposes. The pharmacokinetics of these BiNPs can be easily improved via the facile modification of their surfaces with biocompatible polymers and proteins, resulting in enhanced colloidal stability, extended blood circulation, and reduced toxicity. Desirable antibacterial effects, bone regeneration potential, and tumor growth suppression under NIR laser radiation are the main biomedical research areas involving BiNPs that have opened up a new paradigm for their future clinical translation. This review emphasizes the synthesis and state-of-the-art progress related to the biomedical applications of BiNPs with different structures, sizes, and compositions. Furthermore, a comprehensive discussion focusing on challenges and future opportunities is presented.
Collapse
Affiliation(s)
- Mohammad-Ali Shahbazi
- Drug Research Program, Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, FI-00014 University of Helsinki, Helsinki, Finland.
| | | | | | | | | | | | | | | |
Collapse
|
6
|
Stępniowska A, Sztanke M, Tuzimski T, Korolczuk M, Sztanke K. Square-wave adsorptive stripping voltammetric approaches at two in situ modified electrodes as first analytical methods for the quantitative determination of a new anticancer drug candidate. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY 2019. [DOI: 10.1007/s13738-019-01735-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
7
|
Nuñez RN, Moreno Betancourth J, Ortiz PI, Pfaffen V. Voltammetric Quantification of 4-Nitrophenol Using a Multivariate Optimized Plated Bismuth Film Electrode. Ind Eng Chem Res 2019. [DOI: 10.1021/acs.iecr.9b01700] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Rodrigo N. Nuñez
- INFIQC−CONICET and Universidad Nacional de Córdoba, Ciudad Universitaria, 5000 Córdoba, Argentina
| | | | - Patricia I. Ortiz
- INFIQC−CONICET and Universidad Nacional de Córdoba, Ciudad Universitaria, 5000 Córdoba, Argentina
| | - Valeria Pfaffen
- INFIQC−CONICET and Universidad Nacional de Córdoba, Ciudad Universitaria, 5000 Córdoba, Argentina
| |
Collapse
|
8
|
Stępniowska A, Sztanke M, Tuzimski T, Korolczuk M, Sztanke K. A simple stripping voltammetric method for the determination of a new anticancer prodrug in serum. Biosens Bioelectron 2017; 94:584-588. [PMID: 28364705 DOI: 10.1016/j.bios.2017.03.053] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2017] [Accepted: 03/24/2017] [Indexed: 10/19/2022]
Abstract
The determination of ethyl [4-oxo-8-(3-chlorophenyl)-4,6,7,8-tetrahydroimidazo[2,1-c][1,2,4]triazin-3-yl]acetate (ETTA), a new anticancer prodrug, using adsorptive stripping voltammetry (AdSV) was described for the first time. This method is based on adsorptive/reductive behaviour of ETTA at an in situ plated bismuth film electrode (BiFE) as a sensor. A number of experimental variables (e.g., a composition and pH of the supporting electrolyte, the conditions of bismuth film deposition, an accumulation potential and time, the scan rate, etc.) were thoroughly studied in order to achieve a high sensitivity. Experimental results under optimized conditions revealed an excellent linear correlation between the monitored voltammetric peak current and the ETTA concentration in the range of 2-50μgL-1 following an accumulation time of 300s. The limit of detection (LOD) for ETTA following 300s of an accumulation time was 0.4μgL-1. The proposed facile, sensitive and inexpensive method was successfully applied to the determination of ETTA in serum. The investigated prodrug was extracted from serum using SPE method.
Collapse
Affiliation(s)
- Anna Stępniowska
- Department of Biochemistry and Toxicology, University of Life Sciences in Lublin, 13 Akademicka, 20-950 Lublin, Poland.
| | - Małgorzata Sztanke
- Chair and Department of Medical Chemistry, Medical University of Lublin, 4A Chodźki Street, 20-093 Lublin, Poland
| | - Tomasz Tuzimski
- Department of Physical Chemistry, Chair of Chemistry, Faculty of Pharmacy with Medical Analytics Division, Medical University of Lublin, 4A Chodźki Street, 20-093 Lublin, Poland
| | - Mieczysław Korolczuk
- Faculty of Chemistry, Maria Curie-Skłodowska University, 3 Maria Curie-Skłodowska Sq., 20-031 Lublin, Poland
| | - Krzysztof Sztanke
- Laboratory of Bioorganic Synthesis and Analysis, Chair and Department of Medical Chemistry, Medical University of Lublin, 4A Chodźki Street, 20-093 Lublin, Poland
| |
Collapse
|
9
|
Tseliou F, Avgeropoulos A, Falaras P, Prodromidis MI. Low dimensional Bi 2 Te 3 -graphene oxide hybrid film-modified electrodes for ultra-sensitive stripping voltammetric detection of Pb(II) and Cd(II). Electrochim Acta 2017. [DOI: 10.1016/j.electacta.2017.02.058] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
|
10
|
Bismuth nanoparticles-carbon nanotubes modified sensor for sulfasalazine analysis. Talanta 2017; 164:201-208. [DOI: 10.1016/j.talanta.2016.11.059] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2016] [Revised: 11/23/2016] [Accepted: 11/27/2016] [Indexed: 01/04/2023]
|
11
|
Vladislavić N, Buzuk M, Brinić S, Buljac M, Bralić M. Morphological characterization of ex situ prepared bismuth film electrodes and their application in electroanalytical determination of the biomolecules. J Solid State Electrochem 2016. [DOI: 10.1007/s10008-016-3234-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
12
|
Ochiai LM, Bindewald EH, Mengarda P, Marcolino-Junior LH, Bergamini MF. Disposable potentiometric citrate sensor based on polypyrrole-doped films for indirect determination of sildenafil in pharmaceuticals formulations. J Appl Polym Sci 2016. [DOI: 10.1002/app.43762] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Leticia M. Ochiai
- Departamento De Química, Laboratório De Sensores Eletroquímicos - LabSensE; Universidade Federal Do Paraná; Curitiba-PR Brazil
| | - Eduardo H. Bindewald
- Departamento De Química, Laboratório De Sensores Eletroquímicos - LabSensE; Universidade Federal Do Paraná; Curitiba-PR Brazil
| | - Priscilla Mengarda
- Departamento De Química, Laboratório De Sensores Eletroquímicos - LabSensE; Universidade Federal Do Paraná; Curitiba-PR Brazil
| | - Luiz H. Marcolino-Junior
- Departamento De Química, Laboratório De Sensores Eletroquímicos - LabSensE; Universidade Federal Do Paraná; Curitiba-PR Brazil
| | - Márcio F Bergamini
- Departamento De Química, Laboratório De Sensores Eletroquímicos - LabSensE; Universidade Federal Do Paraná; Curitiba-PR Brazil
| |
Collapse
|
13
|
Gerent GG, Spinelli A. Environmentally-friendly in situ plated bismuth-film electrode for the quantification of the endocrine disruptor parathion in skimmed milk. JOURNAL OF HAZARDOUS MATERIALS 2016; 308:157-163. [PMID: 26812083 DOI: 10.1016/j.jhazmat.2016.01.038] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/21/2015] [Revised: 12/30/2015] [Accepted: 01/14/2016] [Indexed: 06/05/2023]
Abstract
An in situ bismuth-film electrode (BiFE) together with square-wave cathodic voltammetry (SWCV) was used to determine the concentration of the endocrine disruptor parathion in skimmed milk. The experimental conditions (deposition time, deposition potential and Bi (III) concentration) were optimized for the preparation of the BiFE. A glassy carbon electrode was used as the substrate. The selection of the chemical composition of the supporting electrolyte and the solution pH was aimed at improving the reduction of parathion at the BiFE surface. In addition, the parameters of the square-wave cathodic voltammetry were adjusted to improve the sensor performance. A cathodic current identified at -0.523 V increased linearly with the parathion concentration in the range of 0.2-2.0 μmol L(-1) (R=0.999). The sensitivity of the calibration curve obtained was 4.09 μA L μmol(-1), and the limits of detection (LOD) and quantification (LOQ) were 55.7 nmol L(-1) and 169.0 nmol L(-1), respectively. The performance of the sensor was tested using a sample of skimmed milk with parathion added. The same determination was carried out by UV-vis spectroscopy and the results obtained were used for the statistical evaluation of the data obtained.
Collapse
Affiliation(s)
- Giles G Gerent
- Grupo de Estudos de Processos Eletroquímicos e Eletroanalíticos, Universidade Federal de Santa Catarina, Campus Universitário Reitor João David Ferreira Lima, Departamento de Química-CFM, 88040-900, Florianópolis SC, Brazil
| | - Almir Spinelli
- Grupo de Estudos de Processos Eletroquímicos e Eletroanalíticos, Universidade Federal de Santa Catarina, Campus Universitário Reitor João David Ferreira Lima, Departamento de Química-CFM, 88040-900, Florianópolis SC, Brazil.
| |
Collapse
|
14
|
Gerent GG, Gonçalves CQ, da Silva PS, Spinelli A. In situ bismuth-film electrode for square-wave cathodic voltammetric detection of pendimethalin at nanomolar level. Electrochim Acta 2015. [DOI: 10.1016/j.electacta.2015.03.207] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
15
|
Riman D, Avgeropoulos A, Hrbac J, Prodromidis MI. Sparked-bismuth oxide screen-printed electrodes for the determination of riboflavin in the sub-nanomolar range in non-deoxygenated solutions. Electrochim Acta 2015. [DOI: 10.1016/j.electacta.2015.03.056] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
16
|
Sopha H, Roche J, Švancara I, Kuhn A. Wireless Electrosampling of Heavy Metals for Stripping Analysis with Bismuth-Based Janus Particles. Anal Chem 2014; 86:10515-9. [DOI: 10.1021/ac5033897] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Hanna Sopha
- Université de Bordeaux, ISM, UMR 5255, ENSCBP, 33607 Pessac, France
- Department
of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 532 10 Pardubice, Czech Republic
| | - Jérome Roche
- Université de Bordeaux, ISM, UMR 5255, ENSCBP, 33607 Pessac, France
| | - Ivan Švancara
- Department
of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 532 10 Pardubice, Czech Republic
| | - Alexander Kuhn
- Université de Bordeaux, ISM, UMR 5255, ENSCBP, 33607 Pessac, France
| |
Collapse
|
17
|
Fernandes AM, Abdalhai MH, Ji J, Xi BW, Xie J, Sun J, Noeline R, Lee BH, Sun X. Development of highly sensitive electrochemical genosensor based on multiwalled carbon nanotubes-chitosan-bismuth and lead sulfide nanoparticles for the detection of pathogenic Aeromonas. Biosens Bioelectron 2014; 63:399-406. [PMID: 25127474 DOI: 10.1016/j.bios.2014.07.054] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2014] [Revised: 06/27/2014] [Accepted: 07/22/2014] [Indexed: 12/28/2022]
Abstract
In this paper, we reported the construction of new high sensitive electrochemical genosensor based on multiwalled carbon nanotubes-chitosan-bismuth complex (MWCNT-Chi-Bi) and lead sulfide nanoparticles for the detection of pathogenic Aeromonas. Lead sulfide nanoparticles capped with 5'-(NH2) oligonucleotides thought amide bond was used as signalizing probe DNA (sz-DNA) and thiol-modified oligonucleotides sequence was used as fixing probe DNA (fDNA). The two probes hybridize with target Aeromonas DNA (tDNA) sequence (fDNA-tDNA-szDNA). The signal of hybridization is detected by differential pulse voltammetry (DPV) after electrodeposition of released lead nanoparticles (PbS) from sz-DNA on the surface of glass carbon electrode decorated with MWCNT-Chi-Bi, which improves the deposition and traducing electrical signal. The optimization of incubation time, hybridization temperature, deposition potential, deposition time and the specificity of the probes were investigated. Our results showed the highest sensibility to detect the target gene when compared with related biosensors and polymerase chain reaction (PCR). The detection limit for this biosensor was 1.0×10(-14) M. We could detect lower than 10(2) CFU mL(-1) of Aeromonas in spiked tap water. This method is rapid and sensitive for the detection of pathogenic bacteria and would become a potential application in biomedical diagnosis, food safety and environmental monitoring.
Collapse
Affiliation(s)
- António Maximiano Fernandes
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Synergetic Innovation Center of Food Safety and Nutrition, Jiangnan University, Wuxi, Jiangsu 7214122, China.
| | - Mandour H Abdalhai
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Synergetic Innovation Center of Food Safety and Nutrition, Jiangnan University, Wuxi, Jiangsu 7214122, China
| | - Jian Ji
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Synergetic Innovation Center of Food Safety and Nutrition, Jiangnan University, Wuxi, Jiangsu 7214122, China
| | - Bing-Wen Xi
- Key Laboratory of Freshwater Fisheries and Germplasm Resources Utilization, Ministry of Agriculture, Freshwater Fisheries Research Center, Chinese Academy of Fishery Sciences, Wuxi 214081, China
| | - Jun Xie
- Key Laboratory of Freshwater Fisheries and Germplasm Resources Utilization, Ministry of Agriculture, Freshwater Fisheries Research Center, Chinese Academy of Fishery Sciences, Wuxi 214081, China
| | - Jiadi Sun
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Synergetic Innovation Center of Food Safety and Nutrition, Jiangnan University, Wuxi, Jiangsu 7214122, China
| | - Rasoamandrary Noeline
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Synergetic Innovation Center of Food Safety and Nutrition, Jiangnan University, Wuxi, Jiangsu 7214122, China
| | - Byong H Lee
- School of Biotechnology, Jiangnan University, 1800 Lihu Road, Wuxi 214122, China
| | - Xiulan Sun
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Synergetic Innovation Center of Food Safety and Nutrition, Jiangnan University, Wuxi, Jiangsu 7214122, China.
| |
Collapse
|
18
|
Sadeghi S, Motaharian A. Voltammetric sensor based on carbon paste electrode modified with molecular imprinted polymer for determination of sulfadiazine in milk and human serum. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2013; 33:4884-91. [DOI: 10.1016/j.msec.2013.08.001] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2012] [Revised: 06/28/2013] [Accepted: 08/05/2013] [Indexed: 10/26/2022]
|
19
|
Nigović B, Hocevar SB. Square-wave voltammetric determination of pantoprazole using ex situ plated antimony-film electrode. Electrochim Acta 2013. [DOI: 10.1016/j.electacta.2013.07.173] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|
20
|
|
21
|
Brinić S, Vladislavić N, Buzuk M, Bralić M, Šolić M. Bismuth film random array carbon fiber microelectrodes for determination of cysteine and N-acetyl cysteine. J Electroanal Chem (Lausanne) 2013. [DOI: 10.1016/j.jelechem.2013.07.031] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
22
|
Kreft GL, de Braga OC, Spinelli A. Analytical electrochemistry of vitamin B12 on a bismuth-film electrode surface. Electrochim Acta 2012. [DOI: 10.1016/j.electacta.2012.07.132] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
23
|
Kyrisoglou C, Economou A, Efstathiou CE. Bismuth-Coated Iridium Microwire Electrode for the Determination of Trace Metals by Anodic Stripping Voltammetry. ELECTROANAL 2012. [DOI: 10.1002/elan.201200239] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|