1
|
Chen H, Gu T, Lv L, Chen X, Lu Q, Kotb A, Chen W. A Biocompatible, Highly Sensitive, and Non-Enzymatic Glucose Electrochemical Sensor Based on a Copper-Cysteamine (Cu-Cy)/Chitosan-Modified Electrode. NANOMATERIALS (BASEL, SWITZERLAND) 2024; 14:1430. [PMID: 39269092 PMCID: PMC11397198 DOI: 10.3390/nano14171430] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2024] [Revised: 08/29/2024] [Accepted: 08/30/2024] [Indexed: 09/15/2024]
Abstract
A biocompatible, highly sensitive, and enzyme-free glucose electrochemical sensor was developed based on a copper-cysteamine (Cu-Cy)-modified electrode. The catalytically active biocompatible material Cu-Cy was immobilized on the electrode surface by the natural polymer chitosan (CTS). The electrochemical characterization and glucose response of the Cu-Cy/CTS/glassy carbon electrode (GCE) were investigated by electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), and constant potential amperometry. The significant electrocatalytic activity of Cu-Cy to the oxidation of glucose in an alkaline environment was revealed. Several crucial parameters, including the number of scanning cycles for electrode activation, applied potential, and the contents of Cu-Cy and chitosan, were investigated to understand their impact on the sensor's response. The proposed sensing platform exhibited linear ranges of 2.7 μM to 1.3 mM and 1.3 mM to 7.7 mM for glucose detection, coupled with high sensitivity (588.28 and 124.42 μA·mM-1·cm-2), and commendable selectivity and stability. Moreover, a Cu-Cy/CTS-modified screen-printed electrode (SPE) was further developed for portable direct detection of glucose in real samples.
Collapse
Affiliation(s)
- Huan Chen
- School of Chemical Engineering, University of Science and Technology Liaoning, Anshan 114051, China
| | - Tingting Gu
- School of Chemical Engineering, University of Science and Technology Liaoning, Anshan 114051, China
| | - Longyang Lv
- School of Chemical Engineering, University of Science and Technology Liaoning, Anshan 114051, China
| | - Xing Chen
- School of Chemical Engineering, University of Science and Technology Liaoning, Anshan 114051, China
| | - Qifeng Lu
- School of Chips, XJTLU Entrepreneur College (Taicang), Xi'an Jiaotong-Liverpool University, Taicang, Suzhou 215400, China
| | - Amer Kotb
- School of Chips, XJTLU Entrepreneur College (Taicang), Xi'an Jiaotong-Liverpool University, Taicang, Suzhou 215400, China
| | - Wei Chen
- School of Chips, XJTLU Entrepreneur College (Taicang), Xi'an Jiaotong-Liverpool University, Taicang, Suzhou 215400, China
| |
Collapse
|
2
|
Qu N, Song K, Ji Y, Liu M, Chen L, Lee RJ, Teng L. Albumin Nanoparticle-Based Drug Delivery Systems. Int J Nanomedicine 2024; 19:6945-6980. [PMID: 39005962 PMCID: PMC11246635 DOI: 10.2147/ijn.s467876] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2024] [Accepted: 05/28/2024] [Indexed: 07/16/2024] Open
Abstract
Nanoparticle-based systems are extensively investigated for drug delivery. Among others, with superior biocompatibility and enhanced targeting capacity, albumin appears to be a promising carrier for drug delivery. Albumin nanoparticles are highly favored in many disease therapies, as they have the proper chemical groups for modification, cell-binding sites for cell adhesion, and affinity to protein drugs for nanocomplex generation. Herein, this review summarizes the recent fabrication techniques, modification strategies, and application of albumin nanoparticles. We first discuss various albumin nanoparticle fabrication methods, from both pros and cons. Then, we provide a comprehensive introduction to the modification section, including organic albumin nanoparticles, metal albumin nanoparticles, inorganic albumin nanoparticles, and albumin nanoparticle-based hybrids. We finally bring further perspectives on albumin nanoparticles used for various critical diseases.
Collapse
Affiliation(s)
- Na Qu
- School of Pharmacy, Liaoning University, Shenyang, 110036, People's Republic of China
| | - Ke Song
- MERLN Institute for Technology-Inspired Regenerative Medicine, Maastricht University, Maastricht, 6229 ER, the Netherlands
| | - Yating Ji
- School of Pharmacy, Liaoning University, Shenyang, 110036, People's Republic of China
| | - Mingxia Liu
- School of Pharmacy, Liaoning University, Shenyang, 110036, People's Republic of China
| | - Lijiang Chen
- School of Pharmacy, Liaoning University, Shenyang, 110036, People's Republic of China
| | - Robert J Lee
- School of Life Sciences, Jilin University, Changchun, 130023, People's Republic of China
- College of Pharmacy, The Ohio State University, Columbus, OH, 43210, USA
| | - Lesheng Teng
- School of Life Sciences, Jilin University, Changchun, 130023, People's Republic of China
- State Key Laboratory of Long-Acting and Targeting Drug Delivery System, Yantai, 264000, People's Republic of China
| |
Collapse
|
3
|
Aydın M, Aydın EB, Sezgintürk MK. Carboxyethylsilanetriol-Coated Magnetic Nanoparticles as an Ultrasensitive Immunoplatform for Electrochemical Magnetosensing of Cotinine. ACS Biomater Sci Eng 2024; 10:2567-2580. [PMID: 38529538 DOI: 10.1021/acsbiomaterials.3c01872] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/27/2024]
Abstract
In the present study, an innovative and simple electrochemical magneto biosensor based on carboxyethylsilanetriol-modified iron oxide (Fe3O4) magnetic nanoparticles was designed for ultrasensitive and specific analysis of cotinine, an important marker of smoking. Anticotinine antibodies were covalently immobilized on carboxylic acid-modified magnetic nanoparticles, and the cotinine-specific magnetic nanoparticles created a specific surface on the working electrode surface. The use of magnetic nanoparticles as an immobilization platform for antibodies provided a large surface area for antibody attachment and increased sensitivity. In addition, the advantages of the new immobilization platform were reusing the working electrode numerous times, recording repeatable and reproducible signals, and reducing the necessary volume of biomolecules. The specific interaction between cotinine and cotinine-specific antibody-attached magnetic nanoparticles restricted the electron transfer of the redox probe and changed the impedimetric response of the electrode correlated to the concentration of cotinine. The magneto biosensor had a wide detection range (2-300 pg/mL), a low LOD (606 fg/mL), and an acceptable recovery (97.24-105.31%) in real samples. In addition, the current biosensor's measurement results were in good agreement with those found by the standard liquid chromatography (HPLC) and enzyme-linked immunosorbent assay (ELISA) methods. These results showed that a simple impedimetric immunosensing platform was generated for the cotinine analysis.
Collapse
Affiliation(s)
- Muhammet Aydın
- Tekirdağ Namık Kemal University, Scientific and Technological Research Center, Tekirdağ 59030, Turkey
| | - Elif Burcu Aydın
- Tekirdağ Namık Kemal University, Scientific and Technological Research Center, Tekirdağ 59030, Turkey
| | - Mustafa Kemal Sezgintürk
- Çanakkale Onsekiz Mart University, Faculty of Engineering, Bioengineering Department, Çanakkale 17110, Turkey
| |
Collapse
|
4
|
Zhang M, Zhao Y, Bui B, Tang L, Xue J, Chen M, Chen W. The Latest Sensor Detection Methods for per- and Polyfluoroalkyl Substances. Crit Rev Anal Chem 2024:1-17. [PMID: 38234139 DOI: 10.1080/10408347.2023.2299233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2024]
Abstract
Per- and polyfluoroalkyl substances (PFASs) have emerged as a prominent environmental pollutant in recent years, primarily due to their tendency to accumulate and magnify in both the environment and living organisms. The entry of PFASs into the environment can have detrimental effects on human health. Hence, it is crucial to actively monitor and detect the presence of PFASs. The current standard detection method of PFAS is the combination of chromatography and mass spectrometry. However, this requires expensive instruments, extra sample pretreatment steps, complicated operation and long analysis time. As a result, new methods that do not rely on chromatography and mass spectrometry have been developed and applied. These alternative methods mainly include optical and electrochemical sensor methods, which offer great potential in terms of real-time field detection, instrument miniaturization, shorter analysis time, and reduced detection cost. This review provides a summary of recent advancements in PFAS detection sensors. We categorize and explain the principles and mechanisms of these sensors, and compare their limits of detection and sensitivity. Finally, we discuss the future challenges and improvements needed for PFAS sensors, such as field application, commercialization, and other related issues.
Collapse
Affiliation(s)
- Mingyu Zhang
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Shenyang, China
| | - Yanan Zhao
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Shenyang, China
| | - Brian Bui
- Department of Physics, The University of Texas at Arlington, Arlington, Texas, USA
| | - Liming Tang
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Shenyang, China
| | - Jiajia Xue
- Beijing Laboratory of Biomedical Materials and State Key Laboratory of Organic-Inorganic Composites, Beijing University of Chemical Technology, Beijing, China
| | - Mingli Chen
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Shenyang, China
| | - Wei Chen
- Department of Physics, The University of Texas at Arlington, Arlington, Texas, USA
- School of CHIPS, Xi'an Jiaotong-Loverpool University, Suzhou, China
| |
Collapse
|
5
|
Poltavets V, Krawczyk M, Maslak G, Abraimova O, Jönsson-Niedziółka M. Formation of MnO 2-coated ITO electrodes with high catalytic activity for enzymatic glucose detection. Dalton Trans 2023; 52:13769-13780. [PMID: 37721014 DOI: 10.1039/d3dt02199h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/19/2023]
Abstract
We present the formation of a cheap and environmentally friendly working electrode material for glucose biosensors with good catalytic properties. The classic electrode in such devices consists of a conductive material modified with the enzyme glucose oxidase. The working principle is the electrochemical detection of hydrogen peroxide as a product of the enzymatic transformation of glucose. As a base material, we offer manganese dioxide; it is a natural highly selective catalyst for the decomposition of H2O2 and is electrochemically deposited onto the surface of ITO. We approached the formation of MnO2 films systematically. By changing parameters such as the deposition method, pH of the electrolyte, and the drying temperature of the precipitate, a series of electrodes were formed. These electrodes were characterized by SEM, electrochemical impedance spectroscopy, and XPS and their electrocatalytic activity was studied. Significant differences in the sensitivity of the electrodes were detected. The manganese dioxide film with the best catalytic characteristics is formed in the electrolyte with pH 1 by cyclic voltammetry and then drying at 60 °C. The surface of the electrode was then modified with a solution of GOx enzyme with a concentration of 2 mg ml-1 (100-250 units per mg solid). The sensitivity of such an electrode is 117.8 μA mmol-1 cm-2. The range of determined concentrations of glucose is from 0.1 mM to 3 mM. The sensitivity is comparable to that of electrodes based on expensive materials such as graphene and noble metals.
Collapse
Affiliation(s)
- Veronika Poltavets
- Charge Transfer in Hydrodynamic Systems group, Institute of Physical Chemistry of the Polish Academy of Sciences, Kasprzaka street 44/52, 01-224 Warsaw, Poland.
| | - Mirosław Krawczyk
- Charge Transfer in Hydrodynamic Systems group, Institute of Physical Chemistry of the Polish Academy of Sciences, Kasprzaka street 44/52, 01-224 Warsaw, Poland.
| | - Ganna Maslak
- Department of Biochemistry and Medical Chemistry, Dnipro State Medical University, ul. Volodymyr Vernadsky 9, 49044 Dnipro, Ukraine.
| | - Olga Abraimova
- Department of Biochemistry and Medical Chemistry, Dnipro State Medical University, ul. Volodymyr Vernadsky 9, 49044 Dnipro, Ukraine.
| | - Martin Jönsson-Niedziółka
- Charge Transfer in Hydrodynamic Systems group, Institute of Physical Chemistry of the Polish Academy of Sciences, Kasprzaka street 44/52, 01-224 Warsaw, Poland.
| |
Collapse
|
6
|
Pourali P, Dzmitruk V, Pátek M, Neuhöferová E, Svoboda M, Benson V. Fate of the capping agent of biologically produced gold nanoparticles and adsorption of enzymes onto their surface. Sci Rep 2023; 13:4916. [PMID: 36966192 PMCID: PMC10039949 DOI: 10.1038/s41598-023-31792-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Accepted: 03/17/2023] [Indexed: 03/27/2023] Open
Abstract
Enzymotherapy based on DNase I or RNase A has often been suggested as an optional strategy for cancer treatment. The efficacy of such procedures is limited e.g. by a short half-time of the enzymes or a low rate of their internalization. The use of nanoparticles, such as gold nanoparticles (AuNPs), helps to overcome these limits. Specifically, biologically produced AuNPs represent an interesting variant here due to naturally occurring capping agents (CA) on their surface. The composition of the CA depends on the producing microorganism. CAs are responsible for the stabilization of the nanoparticles, and promote the direct linking of targeting and therapeutic molecules. This study provided proof of enzyme adsorption onto gold nanoparticles and digestion efficacy of AuNPs-adsorbed enzymes. We employed Fusarium oxysporum extract to produce AuNPs. These nanoparticles were round or polygonal with a size of about 5 nm, negative surface charge of about - 33 mV, and maximum absorption peak at 530 nm. After the adsorption of DNAse I, RNase A, or Proteinase K onto the AuNPs surface, the nanoparticles exhibited shifts in surface charge (values between - 22 and - 13 mV) and maximum absorption peak (values between 513 and 534 nm). The ability of AuNP-enzyme complexes to digest different targets was compared to enzymes alone. We found a remarkable degradation of ssDNA, and dsDNA by AuNP-DNAse I, and a modest degradation of ssRNA by AuNP-RNase A. The presence of particular enzymes on the AuNP surface was proved by liquid chromatography-mass spectrometry (LC-MS). Using SDS-PAGE electrophoresis, we detected a remarkable digestion of collagen type I and fibrinogen by AuNP-proteinase K complexes. We concluded that the biologically produced AuNPs directly bound DNase I, RNase A, and proteinase K while preserving their ability to digest specific targets. Therefore, according to our results, AuNPs can be used as effective enzyme carriers and the AuNP-enzyme conjugates can be effective tools for enzymotherapy.
Collapse
Affiliation(s)
- Parastoo Pourali
- Institute of Microbiology, Czech Academy of Sciences, 142 20, Prague, Czech Republic
| | - Volha Dzmitruk
- Center of Molecular Structure, Institute of Biotechnology, Czech Academy of Sciences, 252 50, Prague, Czech Republic
| | - Miroslav Pátek
- Institute of Microbiology, Czech Academy of Sciences, 142 20, Prague, Czech Republic
| | - Eva Neuhöferová
- Institute of Microbiology, Czech Academy of Sciences, 142 20, Prague, Czech Republic
| | - Milan Svoboda
- Institute of Analytical Chemistry, Czech Academy of Sciences, 602 00, Brno, Czech Republic
| | - Veronika Benson
- Institute of Microbiology, Czech Academy of Sciences, 142 20, Prague, Czech Republic.
| |
Collapse
|
7
|
Li YY, Ma XX, Song XY, Ma LL, Li YY, Meng X, Chen YJ, Xu KX, Moosavi-Movahedi AA, Xiao BL, Hong J. Glucose Biosensor Based on Glucose Oxidase Immobilized on BSA Cross-Linked Nanocomposite Modified Glassy Carbon Electrode. SENSORS (BASEL, SWITZERLAND) 2023; 23:3209. [PMID: 36991919 PMCID: PMC10051639 DOI: 10.3390/s23063209] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 03/11/2023] [Accepted: 03/16/2023] [Indexed: 06/19/2023]
Abstract
Glucose sensors based blood glucose detection are of great significance for the diagnosis and treatment of diabetes because diabetes has aroused wide concern in the world. In this study, bovine serum albumin (BSA) was used to cross-link glucose oxidase (GOD) on a glassy carbon electrode (GCE) modified by a composite of hydroxy fullerene (HFs) and multi-walled carbon nanotubes (MWCNTs) and protected with a glutaraldehyde (GLA)/Nafion (NF) composite membrane to prepare a novel glucose biosensor. The modified materials were analyzed by UV-visible spectroscopy (UV-vis), transmission electron microscopy (TEM), and cyclic voltammetry (CV). The prepared MWCNTs-HFs composite has excellent conductivity, the addition of BSA regulates MWCNTs-HFs hydrophobicity and biocompatibility, and better immobilizes GOD on MWCNTs-HFs. MWCNTs-BSA-HFs plays a synergistic role in the electrochemical response to glucose. The biosensor shows high sensitivity (167 μA·mM-1·cm-2), wide calibration range (0.01-3.5 mM), and low detection limit (17 μM). The apparent Michaelis-Menten constant Kmapp is 119 μM. Additionally, the proposed biosensor has good selectivity and excellent storage stability (120 days). The practicability of the biosensor was evaluated in real plasma samples, and the recovery rate was satisfactory.
Collapse
Affiliation(s)
- Yang-Yang Li
- School of Life Sciences, Henan University, Kaifeng 475000, China
| | - Xin-Xin Ma
- School of Life Sciences, Henan University, Kaifeng 475000, China
| | - Xin-Yan Song
- School of Life Sciences, Henan University, Kaifeng 475000, China
| | - Lin-Lin Ma
- School of Life Sciences, Henan University, Kaifeng 475000, China
| | - Yu-Ying Li
- School of Life Sciences, Henan University, Kaifeng 475000, China
| | - Xin Meng
- School of Life Sciences, Henan University, Kaifeng 475000, China
| | - Yu-Jie Chen
- School of Life Sciences, Henan University, Kaifeng 475000, China
| | - Ke-Xin Xu
- School of Life Sciences, Henan University, Kaifeng 475000, China
| | | | - Bao-Lin Xiao
- School of Life Sciences, Henan University, Kaifeng 475000, China
| | - Jun Hong
- School of Life Sciences, Henan University, Kaifeng 475000, China
| |
Collapse
|
8
|
Facile one-step synthesis of poly(styrene-glycidyl methacrylate)-Fe3O4 nanocomposite particles and application potency in glucose biosensors. JOURNAL OF POLYMER RESEARCH 2023. [DOI: 10.1007/s10965-023-03498-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/27/2023]
|
9
|
Moro G, Campos R, Daems E, Maria Moretto L, De Wael K. Haem-Mediated Albumin Biosensing: Towards Voltammetric Detection of PFOA. Bioelectrochemistry 2023; 152:108428. [PMID: 37004377 DOI: 10.1016/j.bioelechem.2023.108428] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Revised: 03/20/2023] [Accepted: 03/22/2023] [Indexed: 03/29/2023]
Abstract
The haem group is a promising redox probe for the design of albumin-based voltammetric sensors. Among the endogenous ligands carried by human serum albumin (hSA), haem is characterised by a reversible redox behaviour and its binding kinetics strongly depend on hSA's conformation, which, in turn, depends on the presence of other ligands. In this work, the potential applicability of haem, especially hemin, as a redox probe was first tested in a proof-of-concept study using perfluorooctanoic acid (PFOA) as model analyte. PFOA is known to bind hSA by occupying Sudlow's I site (FA7) which is spatially related to the haem-binding site (FA1). The latter undergoes a conformational change, which is expected to affect hemin's binding kinetics. To verify this hypothesis, hemin:albumin complexes in the presence/absence of PFOA were first screened by UV-Vis spectroscopy. Once the complex formation was verified, haem was further characterised via electrochemical methods to estimate its electron transfer kinetics. The hemin:albumin:PFOA system was studied in solution, with the aim of describing the multiple equilibria at stake and designing an electrochemical assay for PFOA monitoring. This latter could be integrated with protein-based bioremediation approaches for the treatment of per- and polyfluoroalkyl substances polluted waters. Overall, our preliminary results show how hemin can be applied as a redox probe in albumin-based voltammetric sensing strategies.
Collapse
|
10
|
Mohamad Nor N, Ridhuan NS, Abdul Razak K. Progress of Enzymatic and Non-Enzymatic Electrochemical Glucose Biosensor Based on Nanomaterial-Modified Electrode. BIOSENSORS 2022; 12:bios12121136. [PMID: 36551103 PMCID: PMC9775494 DOI: 10.3390/bios12121136] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Revised: 11/28/2022] [Accepted: 12/02/2022] [Indexed: 05/09/2023]
Abstract
This review covers the progress of nanomaterial-modified electrodes for enzymatic and non-enzymatic glucose biosensors. Fundamental insights into glucose biosensor components and the crucial factors controlling the electrochemical performance of glucose biosensors are discussed in detail. The metal, metal oxide, and hybrid/composite nanomaterial fabrication strategies for the modification of electrodes, mechanism of detection, and significance of the nanomaterials toward the electrochemical performance of enzymatic and non-enzymatic glucose biosensors are compared and comprehensively reviewed. This review aims to provide readers with an overview and underlying concept of producing a reliable, stable, cost-effective, and excellent electrochemical performance of a glucose biosensor.
Collapse
Affiliation(s)
- Noorhashimah Mohamad Nor
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, Nibong Tebal 14300, Pulau Pinang, Malaysia
| | - Nur Syafinaz Ridhuan
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, Nibong Tebal 14300, Pulau Pinang, Malaysia
| | - Khairunisak Abdul Razak
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, Nibong Tebal 14300, Pulau Pinang, Malaysia
- NanoBiotechnology Research & Innovation (NanoBRI), Institute for Research in Molecular Medicine, Universiti Sains Malaysia, Gelugor 11800, Pulau Pinang, Malaysia
- Correspondence:
| |
Collapse
|
11
|
Preparation of three dimensional Cu2O/Au/GO hybrid electrodes and its application as a non-enzymatic glucose sensor. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107451] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
12
|
The dependence of Cu 2O morphology on different surfactants and its application for non-enzymatic glucose detection. Colloids Surf B Biointerfaces 2021; 208:112087. [PMID: 34500204 DOI: 10.1016/j.colsurfb.2021.112087] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Revised: 08/24/2021] [Accepted: 08/27/2021] [Indexed: 01/17/2023]
Abstract
Herein, the Cu2O yolk-shell nanospheres, nanocubes and microcubes were successfully prepared by a simple seed-medium process. The formation of the Cu2O yolk-shell nanospheres can be attributed to the self-assembly process caused by the introduction of the seed medium. The formation mechanism of our obtained Cu2O yolk-shell nanospheres and the dependence of Cu2O morphology on different surfactants have been studied. The obtained samples were applied in the field of non-enzymatic glucose detection. The electrochemical response characteristics of the modified electrodes toward glucose were investigated by cyclic voltammetry (CV) and chronoamperometry (CA). The electrode modified with C-Cu2O (obtained by using CTAB as surfactant) shared the highest sensitivity of 3123 μAmM-1 cm-2, whereas, the electrode modified with S-Cu2O (obtained by using SDBS as surfactant) exhibited the lowest LOD of 0.87 μM and the widest linear range of 0.05-10.65 mM. All obtained sensors showed fast response to the addition of glucose. The obtained electrodes showed better responses to glucose than other coexisting interferences, indicating that the obtained electrodes had the acceptable selectivity to glucose. In addition, the stability for 5 consecutive weeks had also been studied and exhibited satisfactory results. The obtained electrode was also used to detect the glucose content in real serum. The acceptable selectivity, stability together with the excellent sensing ability in real serum make the obtained electrodes a potential for practical applications.
Collapse
|
13
|
da Silva Junior AG, Frias IAM, Lima-Neto RG, Sá SR, Oliveira MDL, Andrade CAS. Concanavalin A differentiates gram-positive bacteria through hierarchized nanostructured transducer. Microbiol Res 2021; 251:126834. [PMID: 34364021 DOI: 10.1016/j.micres.2021.126834] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Revised: 07/23/2021] [Accepted: 07/28/2021] [Indexed: 11/28/2022]
Abstract
Biosensors are pre-prepared diagnostic devices composed of at least one biological probe. These devices are envisaged for the practical identification of specific targets of microbiological interest. In recent years, the use of narrow-specific probes such as lectins has been proven to distinguish bacteria and glycoproteins based on their superficial glycomic pattern. For instance, Concanavalin A is a carbohydrate-binding lectin indicated as a narrow-specific biological probe for Gram-negative bacteria. As a drawback, Gram-positive bacteria are frequently overlooked from lectin-based biosensing studies because their identification results in low resolution and overlapped signals. In this work, the authors explore the effect that platform nanostructuration has over the electrochemical response of ConA-based platforms constructed for bacterial detection; one is formed of chitosan-capped magnetic nanoparticles, and another is composed of gold nanoparticle-decorated magnetic nanoparticles. The biosensing platforms were characterized by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) as a function of bacterial concentration. Our results show that probe-target interaction causes variations in the electrical responses of nanostructured transducers. Moreover, the association of gold nanoparticles to magnetic nanoparticles resulted in an electrical enhancement capable of overcoming low resolution and overlapping Gram-positive identification. Both platforms attained a limit of detection of 10 ° CFU mL-1, which is useful for water analyses and sanitation concerns, where low CFU mL-1 are always expected. Although both platforms were able to detect Gram-negative bacteria, Gram-positives were only correctly differentiated by the gold nanoparticle-decorated magnetic nanoparticles, thus demonstrating the positive influence of hierarchically nanostructured platforms.
Collapse
Affiliation(s)
- Alberto G da Silva Junior
- Programa de Pós-Graduação em Inovação Terapêutica, Universidade Federal de Pernambuco, 50670-901, Recife, PE, Brazil; Laboratório de Biodispositivos Nanoestruturados, Departamento de Bioquímica, Universidade Federal de Pernambuco, 50670-901, Recife, PE, Brazil
| | - Isaac A M Frias
- Programa de Pós-Graduação em Inovação Terapêutica, Universidade Federal de Pernambuco, 50670-901, Recife, PE, Brazil; Laboratório de Biodispositivos Nanoestruturados, Departamento de Bioquímica, Universidade Federal de Pernambuco, 50670-901, Recife, PE, Brazil
| | - Reginaldo G Lima-Neto
- Centro de Ciências da Saúde, Departamento de Medicina Tropical, Universidade Federal de Pernambuco, 50670-901, Recife, PE, Brazil
| | - Sandra R Sá
- Laboratório de Biodispositivos Nanoestruturados, Departamento de Bioquímica, Universidade Federal de Pernambuco, 50670-901, Recife, PE, Brazil
| | - Maria D L Oliveira
- Programa de Pós-Graduação em Inovação Terapêutica, Universidade Federal de Pernambuco, 50670-901, Recife, PE, Brazil; Laboratório de Biodispositivos Nanoestruturados, Departamento de Bioquímica, Universidade Federal de Pernambuco, 50670-901, Recife, PE, Brazil
| | - César A S Andrade
- Programa de Pós-Graduação em Inovação Terapêutica, Universidade Federal de Pernambuco, 50670-901, Recife, PE, Brazil; Laboratório de Biodispositivos Nanoestruturados, Departamento de Bioquímica, Universidade Federal de Pernambuco, 50670-901, Recife, PE, Brazil.
| |
Collapse
|
14
|
Tripathy A, Nine MJ, Silva FS. Biosensing platform on ferrite magnetic nanoparticles: Synthesis, functionalization, mechanism and applications. Adv Colloid Interface Sci 2021; 290:102380. [PMID: 33819727 DOI: 10.1016/j.cis.2021.102380] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2020] [Revised: 01/29/2021] [Accepted: 01/30/2021] [Indexed: 12/17/2022]
Abstract
Ferrite magnetic nanoparticles (FMNPs) are gaining popularity to design biosensors for high-performance clinical diagnosis. The fusion of information shows that FMNPs based biosensors require well-tuned FMNPs as detection probes to produce large and specific biological signals with minimal non-specific binding. Nevertheless, there is a noticeable lacuna of information to solve the issues related to suitable synthesis route, particle size reduction, functionalization, sensitivity towards targeted intercellular biological tiny particles, and lower signal-to-noise ratio. Therefore it allows exploring unique characteristics of FMNPs to design a suitable sensing device for intracellular measurements and diseases detection. This review focuses on the extensively used synthesis routes, their advantages and limitations, crystalline structure, functionalization, along with recent applications of FMNPs in biosensors, taking into consideration their analytical figures of merit and range of linearity. This work also addresses the current progress, key factors for sensitivity, selectivity and productivity improvement along with the challenges, future trends and perspectives of FMNPs based biosensors.
Collapse
|
15
|
Zhang BL, Jin X, Sun LH, Guo XD. Needle-shaped glucose sensor based on polypyrrole doped with glucose oxidase. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105217] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
16
|
Hovancová J, Niščáková V, Šišoláková I, Oriňaková R, Maskaľová I, Oriňak A, Kovaľ K. Gold Microelectrodes Decorated by Spike‐Like Nanostructures as a Promising Non‐Enzymatic Glucose Sensor. ELECTROANAL 2020. [DOI: 10.1002/elan.202060207] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Affiliation(s)
- Jana Hovancová
- Department of Physical Chemistry University of P.J. Šafárik in Košice Moyzesova 11 040 01 Košice Slovakia
| | - Veronika Niščáková
- Department of Physical Chemistry University of P.J. Šafárik in Košice Moyzesova 11 040 01 Košice Slovakia
| | - Ivana Šišoláková
- Department of Physical Chemistry University of P.J. Šafárik in Košice Moyzesova 11 040 01 Košice Slovakia
| | - Renáta Oriňaková
- Department of Physical Chemistry University of P.J. Šafárik in Košice Moyzesova 11 040 01 Košice Slovakia
| | - Iveta Maskaľová
- Department of Nutrition, Dietetics, and Animal Breeding University of Veterinary Medicine and Pharmacy in Košice Komenského 73 041 81 Košice Slovakia
| | - Andrej Oriňak
- Department of Physical Chemistry University of P.J. Šafárik in Košice Moyzesova 11 040 01 Košice Slovakia
| | - Karol Kovaľ
- Institute of Materials Research Slovak Academy of Sciences Watsonova 47 040 01 Košice Slovakia
| |
Collapse
|
17
|
Bakirhan NK, Topal BD, Ozcelikay G, Karadurmus L, Ozkan SA. Current Advances in Electrochemical Biosensors and Nanobiosensors. Crit Rev Anal Chem 2020; 52:519-534. [DOI: 10.1080/10408347.2020.1809339] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Affiliation(s)
- Nurgul K. Bakirhan
- Department of Analytical Chemistry, Gulhane Faculty of Pharmacy, University of Health Sciences, Ankara, Turkey
| | - Burcu D. Topal
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - Goksu Ozcelikay
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - Leyla Karadurmus
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
- Department of Analytical Chemistry, Faculty of Pharmacy, Adıyaman University, Adıyaman, Turkey
| | - Sibel A. Ozkan
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| |
Collapse
|
18
|
Nan MN, Bi Y, Xue HL, Long HT, Xue SL, Pu LM, Prusky D. Modification performance and electrochemical characteristics of different groups of modified aptamers applied for label-free electrochemical impedimetric sensors. Food Chem 2020; 337:127761. [PMID: 32777565 DOI: 10.1016/j.foodchem.2020.127761] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2019] [Revised: 07/12/2020] [Accepted: 08/02/2020] [Indexed: 11/15/2022]
Abstract
Amino and thiolated aptamers are the main aptamers used to construct label-free electrochemical impedimetric aptasensors. In this study, the modification performance and electrochemical properties of amino aptamers and thiolated aptamers were studied in the construction of label-free impedimetric sensors. The results showed that the initial modification density of amino aptamers was higher than that of thiol aptamers. Aptamers can recognize and bind OTA to generate electrical signals. The higher the density of aptamer modification was, the better the electric signals were. If only considering the initial modification density, amino aptamers were more suitable for the preparation of aptasensors than thiolated aptamers. However, the modification density of the amino aptamer decreased with the prolonged immersion time in 1 mM HCl solution, which suggests that the stability of this sensor was poor. However, the thiolated aptamer maintained relatively constant density and could be reused. Thus, the thiolated aptasensor had a wide range and good reproducibility and stability for the determination of ochratoxin A (OTA). In addition, this study proved that gold nanoparticles play an important role in signal amplification by increasing the effective gold surface to fix more aptamers in the process of sensor preparation.
Collapse
Affiliation(s)
- Mi-Na Nan
- College of Science, Gansu Agricultural University, Lanzhou 730070, PR China; College of Horticulture, Gansu Agricultural University, Lanzhou 730070, PR China
| | - Yang Bi
- College of Food Science and Engineering, Gansu Agricultural University, Lanzhou 730070, PR China.
| | - Hua-Li Xue
- College of Science, Gansu Agricultural University, Lanzhou 730070, PR China.
| | - Hai-Tao Long
- College of Science, Gansu Agricultural University, Lanzhou 730070, PR China
| | - Su-Lin Xue
- College of Horticulture, Gansu Agricultural University, Lanzhou 730070, PR China
| | - Lu-Mei Pu
- College of Science, Gansu Agricultural University, Lanzhou 730070, PR China
| | - Dov Prusky
- College of Food Science and Engineering, Gansu Agricultural University, Lanzhou 730070, PR China; Department of Postharvest Science of Fresh Produce, the Volcani Center, Agricultural Research Organization, Bet Dagan 50250, Israel
| |
Collapse
|
19
|
Moro G, Bottari F, Liberi S, Covaceuszach S, Cassetta A, Angelini A, De Wael K, Moretto LM. Covalent immobilization of delipidated human serum albumin on poly(pyrrole-2-carboxylic) acid film for the impedimetric detection of perfluorooctanoic acid. Bioelectrochemistry 2020; 134:107540. [PMID: 32361666 DOI: 10.1016/j.bioelechem.2020.107540] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2020] [Revised: 04/20/2020] [Accepted: 04/20/2020] [Indexed: 12/11/2022]
Abstract
The immobilization of biomolecules at screen printed electrodes for biosensing applications is still an open challenge. To enrich the toolbox of bioelectrochemists, graphite screen printed electrodes (G-SPE) were modified with an electropolymerized film of pyrrole-2-carboxilic acid (Py-2-COOH), a pyrrole derivative rich in carboxylic acid functional groups. These functionalities are suitable for the covalent immobilization of biomolecular recognition layers. The electropolymerization was first optimized to obtain stable and conductive polymeric films, comparing two different electrolytes: sodium dodecyl sulphate (SDS) and sodium perchlorate. The G-SPE modified with Py-2-COOH in 0.1 M SDS solution showed the required properties and were further tested. A proof-of-concept study for the development of an impedimetric sensor for perfluorooctanoic acid (PFOA) was carried out using the delipidated human serum albumin (hSA) as bioreceptor. The data interpretation was supported by size exclusion chromatography and small-angle X-ray scattering (SEC-SAXS) analysis of the bioreceptor-target complex and the preliminary results suggest the possibility to further develop this biosensing strategy for toxicological and analytical studies.
Collapse
Affiliation(s)
- Giulia Moro
- Department of Molecular Sciences and Nanosystems, Ca' Foscari University of Venice, Via Torino 155, 30172 Mestre, Italy; AXES Research Group, Department of Bioscience Engineering, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium; NANOlab Center of Excellence, Groenenborgerlaan 171, 2020 Antwerp, Belgium.
| | - Fabio Bottari
- AXES Research Group, Department of Bioscience Engineering, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium; NANOlab Center of Excellence, Groenenborgerlaan 171, 2020 Antwerp, Belgium
| | - Stefano Liberi
- Department of Molecular Sciences and Nanosystems, Ca' Foscari University of Venice, Via Torino 155, 30172 Mestre, Italy
| | - Sonia Covaceuszach
- Istituto di Cristallografia - CNR, Trieste Outstation, Italy SS 14 km 163.5, Basovizza, Trieste, Italy
| | - Alberto Cassetta
- Istituto di Cristallografia - CNR, Trieste Outstation, Italy SS 14 km 163.5, Basovizza, Trieste, Italy
| | - Alessandro Angelini
- Department of Molecular Sciences and Nanosystems, Ca' Foscari University of Venice, Via Torino 155, 30172 Mestre, Italy; European Centre for Living Technology (ECLT), Ca' Bottacin, Dorsoduro 3911, Calle Crosera, 30123 Venice, Italy
| | - Karolien De Wael
- AXES Research Group, Department of Bioscience Engineering, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium; NANOlab Center of Excellence, Groenenborgerlaan 171, 2020 Antwerp, Belgium
| | - Ligia Maria Moretto
- Department of Molecular Sciences and Nanosystems, Ca' Foscari University of Venice, Via Torino 155, 30172 Mestre, Italy
| |
Collapse
|
20
|
Liu W, Chai G, Zhang J, Wang M, Dai Y, Yang Q. Preparation of Cu2O nanocubes with different sizes and rough surfaces by a seed-mediated self-assembly process and their application as a non-enzymatic glucose sensor. NEW J CHEM 2020. [DOI: 10.1039/d0nj02763d] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
In this study, ultrafine and uniform cuprous oxide (Cu2O) nanocubes with different sizes and rough surfaces were prepared via a seed-mediated process.
Collapse
Affiliation(s)
- Wenbin Liu
- School of Materials Science and Engineering
- Northeastern University
- Shenyang
- China
| | - Guochun Chai
- School of Materials Science and Engineering
- Northeastern University
- Shenyang
- China
| | - Jian Zhang
- School of Materials Science and Engineering
- Northeastern University
- Shenyang
- China
| | - Mingguang Wang
- School of Materials Science and Engineering
- Northeastern University
- Shenyang
- China
| | - Yuxiang Dai
- School of Materials Science and Engineering
- Northeastern University
- Shenyang
- China
| | - Qi Yang
- School of Materials Science and Engineering
- Northeastern University
- Shenyang
- China
| |
Collapse
|
21
|
Highly selective and stable glucose biosensor based on incorporation of platinum nanoparticles into polyaniline-montmorillonite hybrid composites. Microchem J 2020. [DOI: 10.1016/j.microc.2019.104266] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
22
|
Kucherenko IS, Soldatkin OO, Kucherenko DY, Soldatkina OV, Dzyadevych SV. Advances in nanomaterial application in enzyme-based electrochemical biosensors: a review. NANOSCALE ADVANCES 2019; 1:4560-4577. [PMID: 36133111 PMCID: PMC9417062 DOI: 10.1039/c9na00491b] [Citation(s) in RCA: 73] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2019] [Accepted: 10/28/2019] [Indexed: 05/06/2023]
Abstract
Electrochemical enzyme-based biosensors are one of the largest and commercially successful groups of biosensors. Integration of nanomaterials in the biosensors results in significant improvement of biosensor sensitivity, limit of detection, stability, response rate and other analytical characteristics. Thus, new functional nanomaterials are key components of numerous biosensors. However, due to the great variety of available nanomaterials, they should be carefully selected according to the desired effects. The present review covers the recent applications of various types of nanomaterials in electrochemical enzyme-based biosensors for the detection of small biomolecules, environmental pollutants, food contaminants, and clinical biomarkers. Benefits and limitations of using nanomaterials for analytical purposes are discussed. Furthermore, we highlight specific properties of different nanomaterials, which are relevant to electrochemical biosensors. The review is structured according to the types of nanomaterials. We describe the application of inorganic nanomaterials, such as gold nanoparticles (AuNPs), platinum nanoparticles (PtNPs), silver nanoparticles (AgNPs), and palladium nanoparticles (PdNPs), zeolites, inorganic quantum dots, and organic nanomaterials, such as single-walled carbon nanotubes (SWCNTs), multi-walled carbon nanotubes (MWCNTs), carbon and graphene quantum dots, graphene, fullerenes, and calixarenes. Usage of composite nanomaterials is also presented.
Collapse
Affiliation(s)
- I S Kucherenko
- Department of Biomolecular Electronics, Institute of Molecular Biology and Genetics of the National Academy of Sciences of Ukraine Zabolotnogo Street 150 Kyiv 03143 Ukraine
- Department of Mechanical Engineering, Iowa State University Ames Iowa 50011 USA
| | - O O Soldatkin
- Department of Biomolecular Electronics, Institute of Molecular Biology and Genetics of the National Academy of Sciences of Ukraine Zabolotnogo Street 150 Kyiv 03143 Ukraine
- Institute of High Technologies, Taras Shevchenko National University of Kyiv Volodymyrska Street 64 Kyiv 01003 Ukraine
| | - D Yu Kucherenko
- Department of Biomolecular Electronics, Institute of Molecular Biology and Genetics of the National Academy of Sciences of Ukraine Zabolotnogo Street 150 Kyiv 03143 Ukraine
| | - O V Soldatkina
- Institute of High Technologies, Taras Shevchenko National University of Kyiv Volodymyrska Street 64 Kyiv 01003 Ukraine
- F. D. Ovcharenko Institute of Biocolloidal Chemistry Acad. Vernadskoho Blvd. 42 Kyiv 03142 Ukraine
| | - S V Dzyadevych
- Department of Biomolecular Electronics, Institute of Molecular Biology and Genetics of the National Academy of Sciences of Ukraine Zabolotnogo Street 150 Kyiv 03143 Ukraine
- Institute of High Technologies, Taras Shevchenko National University of Kyiv Volodymyrska Street 64 Kyiv 01003 Ukraine
| |
Collapse
|
23
|
Abstract
: Nanomaterial biosensors have revolutionized the entire scientific, technology, biomedical, materials science, and engineering fields. Among all nanomaterials, magnetic nanoparticles, microparticles, and beads are unique in offering facile conjugation of biorecognition probes for selective capturing of any desired analytes from complex real sample matrices (e.g., biofluids such as whole blood, serum, urine and saliva, tissues, food, and environmental samples). In addition, rapid separation of the particle-captured analytes by the simple use of a magnet for subsequent detection on a sensor unit makes the magnetic particle sensor approach very attractive. The easy magnetic isolation feature of target analytes is not possible with other inorganic particles, both metallic (e.g., gold) and non-metallic (e.g., silica), which require difficult centrifugation and separation steps. Magnetic particle biosensors have thus enabled ultra-low detection with ultra-high sensitivity that has traditionally been achieved only by radioactive assays and other tedious optical sources. Moreover, when traditional approaches failed to selectively detect low-concentration analytes in complex matrices (e.g., colorimetric, electrochemistry, and optical methods), magnetic particle-incorporated sensing strategies enabled sample concentration into a defined microvolume of large surface area particles for a straightforward detection. The objective of this article is to highlight the ever-growing applications of magnetic materials for the detection of analytes present in various real sample matrices. The central idea of this paper was to show the versatility and advantages of using magnetic particles for a variety of sample matrices and analyte types and the adaptability of different transducers with the magnetic particle approaches.
Collapse
|
24
|
Chen Y, Zhou W, Ma J, Ruan F, Qi X, Cai Y. Potential of a sensitive uric acid biosensor fabricated using hydroxyapatite nanowire/reduced graphene oxide/gold nanoparticle. Microsc Res Tech 2019; 83:268-275. [PMID: 31729094 DOI: 10.1002/jemt.23410] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2018] [Revised: 10/17/2019] [Accepted: 10/24/2019] [Indexed: 12/12/2022]
Abstract
In this study, a ternary nanocomposite consisting of gold nanoparticles (AuNPs), hydroxyapatite (HAP) nanowires, and reduced graphene oxide (rGO) is synthesized by a simple one-step hydrothermal method, which is used to modify glassy carbon electrode (GCE) for detecting uric acid. The nanocomposite is characterized through various methods such as scanning electron microscopy, transmission electron microscopy, and X-ray diffraction. Electrochemical measurements of the modified GCE are performed in a conventional three-electrode system. Experimental results show that the obtained HAP nanowire and rGO are mixed homogeneously, and the AuNPs are deposited into this matrix. The GCE modified by the nanocomposites have superior electrocatalytic activities for uric acid. The peak current intensities of UAO (uricase)/HAP-rGO/AuNPs sensing system linearly increase as the uric acid concentration increases substantially in a range of 1.95 × 10-5 to 6.0 × 10-3 M (R2 = .9943), with a detection limit of 3.9 × 10-6 M (S/N = 3) and analytical sensitivity of 13.86 mA/M. The biosensor performs well in determining uric acid concentration in human urine samples.
Collapse
Affiliation(s)
- Yao Chen
- The Key Laboratory of Advanced Textile Materials and Manufacturing Technology of Ministry of Education, National Engineering Lab for Textile Fiber Materials and Processing Technology, School of Materials Science and Engineering, Zhejiang Sci-Tech University, Hangzhou, China
| | - Wencui Zhou
- The Key Laboratory of Advanced Textile Materials and Manufacturing Technology of Ministry of Education, National Engineering Lab for Textile Fiber Materials and Processing Technology, School of Materials Science and Engineering, Zhejiang Sci-Tech University, Hangzhou, China
| | - Jiahui Ma
- The Key Laboratory of Advanced Textile Materials and Manufacturing Technology of Ministry of Education, National Engineering Lab for Textile Fiber Materials and Processing Technology, School of Materials Science and Engineering, Zhejiang Sci-Tech University, Hangzhou, China
| | - Feixia Ruan
- The Key Laboratory of Advanced Textile Materials and Manufacturing Technology of Ministry of Education, National Engineering Lab for Textile Fiber Materials and Processing Technology, School of Materials Science and Engineering, Zhejiang Sci-Tech University, Hangzhou, China
| | - Xuezhen Qi
- School of Chemistry and Chemical Engineering, Liaocheng University, Liaocheng, China
| | - Yurong Cai
- The Key Laboratory of Advanced Textile Materials and Manufacturing Technology of Ministry of Education, National Engineering Lab for Textile Fiber Materials and Processing Technology, School of Materials Science and Engineering, Zhejiang Sci-Tech University, Hangzhou, China
| |
Collapse
|
25
|
Reyes-De-Corcuera JI, Olstad HE, García-Torres R. Stability and Stabilization of Enzyme Biosensors: The Key to Successful Application and Commercialization. Annu Rev Food Sci Technol 2019; 9:293-322. [PMID: 29580138 DOI: 10.1146/annurev-food-030216-025713] [Citation(s) in RCA: 56] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Fifty-five years have passed and more than 100,000 articles have been published since the first report of an electrochemical enzyme biosensor. However, very few biosensors have reached practical application and commercialization. The bulk of the research effort has been on increasing sensitivity and selectivity. In contrast, the number of publications dealing with stability or stabilization of enzyme biosensors is very small. Here, we critically review enzyme stabilization strategies as well as the progress that has been done in the past 20 years with respect to enzyme biosensor stabilization. Glucose oxidase, lactate oxidase, alcohol oxidase, and xanthine oxidase are the focus of this review because of their potential applications in food. The inconsistency in reporting biosensor stability was identified as a critical hurdle to research progress in this area. Fundamental questions that remain unanswered are outlined.
Collapse
Affiliation(s)
| | - Hanna E Olstad
- Department of Food Science and Technology, University of Georgia, Athens, Georgia 30602, USA;
| | - Rosalía García-Torres
- Department of Family & Consumer Sciences, California State University, Northridge, California 91330, USA
| |
Collapse
|
26
|
Azimi S, Farahani A, Sereshti H. Plasma‐functionalized Highly Aligned CNT‐based Biosensor for Point of Care Determination of Glucose in Human Blood Plasma. ELECTROANAL 2019. [DOI: 10.1002/elan.201800895] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Affiliation(s)
- Shamim Azimi
- Department of Chemical Engineering, Faculty of EngineeringUniversity of Tehran Tehran 14395-515 Iran
| | - Ali Farahani
- School of Chemistry, College of ScienceUniversity of Tehran Tehran 141761-4411 Iran
| | - Hassan Sereshti
- School of Chemistry, College of ScienceUniversity of Tehran Tehran 141761-4411 Iran
| |
Collapse
|
27
|
Li N, Zhang Y, Huang B, Li H. Ultrasonic dispersion temperature- and pH-tuned spectral and electrochemical properties of bovine serum albumin on carbon nanotubes and its conformational transition. Electrochim Acta 2019. [DOI: 10.1016/j.electacta.2018.11.089] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
28
|
Yi W, He Z, Fei J, He X. Sensitive electrochemical sensor based on poly(l-glutamic acid)/graphene oxide composite material for simultaneous detection of heavy metal ions. RSC Adv 2019; 9:17325-17334. [PMID: 35519871 PMCID: PMC9064582 DOI: 10.1039/c9ra01891c] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2019] [Accepted: 05/20/2019] [Indexed: 12/13/2022] Open
Abstract
Heavy metal pollution can be toxic to humans and wildlife, thus it is of great significance to develop rapid and sensitive methods to detect heavy metal ions. Here, a novel type of electrochemical sensor for the simultaneous detection of heavy metal ions has been prepared by using poly(l-glutamic acid) (PGA) and graphene oxide (GO) composite materials to modify the glassy carbon electrode (GCE). Due to the good binding properties of poly(l-glutamic acid) (PGA) for the heavy metal ions (such as Cu2+, Cd2+, and Hg2+) as well as good electron conductivity of graphene oxide (GO), the heavy metal ions, Cu2+, Cd2+, and Hg2+ in aqueous solution can be accurately detected by using differential pulse anodic stripping voltammetry method (DPASV). Under the optimized experiment conditions, the modified GCE shows excellent electrochemical performance toward Cu2+, Cd2+, and Hg2+, and the linear range of PG/GCE for Cu2+, Cd2+, and Hg2+ is 0.25–5.5 μM, and the limits of detection (LODs, S/N ≥ 3) Cu2+, Cd2+, and Hg2+ are estimated to be 0.024 μM, 0.015 μM and 0.032 μM, respectively. Moreover, the modified GCE is successfully applied to the determination of Cu2+, Cd2+, and Hg2+ in real samples. All obtained results show that the modified electrode not only has the advantages of simple preparation, high sensitivity, and good stability, but also can be applied in the field of heavy metal ion detection. A novel electrochemical sensor with high stability and good reproducibility for the simultaneous detection of heavy metal ions was prepared by using PGA/GO to modify the GCE, showing high sensitivity of superior to most of the reported values.![]()
Collapse
Affiliation(s)
- Wei Yi
- School of Chemistry and Molecular Engineering
- East China Normal University
- Shanghai 200241
- China
| | - Zihua He
- School of Chemistry and Molecular Engineering
- East China Normal University
- Shanghai 200241
- China
| | - Junjie Fei
- Key Laboratory of Environmentally Friendly Chemistry and Applications of Ministry of Education
- College of Chemistry
- Xiangtan University
- Xiangtan 411105
- China
| | - Xiaohua He
- School of Chemistry and Molecular Engineering
- East China Normal University
- Shanghai 200241
- China
| |
Collapse
|
29
|
Yi W, Ji C, Fei J, He X. Reversible Switched pH‐Responsive Hydroquinone Electrochemical Sensor Based on Composite Film of Polystyrene‐
b
‐Poly (Acrylic Acid) and Graphene Oxide. ELECTROANAL 2018. [DOI: 10.1002/elan.201800600] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Affiliation(s)
- Wei Yi
- School of Chemistry and Molecular EngineeringEast China Normal University 500 Dongchuan Road Shanghai 200241 China
| | - Cuihong Ji
- School of Chemistry and Molecular EngineeringEast China Normal University 500 Dongchuan Road Shanghai 200241 China
| | - Junjie Fei
- Key Laboratory of Environmentally Friendly Chemistry and Applications of Ministry of Education, College of ChemistryXiangtan University Xiangtan 411105 China
| | - Xiaohua He
- School of Chemistry and Molecular EngineeringEast China Normal University 500 Dongchuan Road Shanghai 200241 China
| |
Collapse
|
30
|
Alim S, Vejayan J, Yusoff MM, Kafi AKM. Recent uses of carbon nanotubes & gold nanoparticles in electrochemistry with application in biosensing: A review. Biosens Bioelectron 2018; 121:125-136. [PMID: 30205246 DOI: 10.1016/j.bios.2018.08.051] [Citation(s) in RCA: 99] [Impact Index Per Article: 14.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2018] [Accepted: 08/20/2018] [Indexed: 01/06/2023]
Abstract
The innovation of nanoparticles assumes a critical part of encouraging and giving open doors and conceivable outcomes to the headway of new era devices utilized as a part of biosensing. The focused on the quick and legitimate detecting of specific biomolecules using functionalized gold nanoparticles (Au NPs), and carbon nanotubes (CNTs) has turned into a noteworthy research enthusiasm for the most recent decade. Sensors created with gold nanoparticles or carbon nanotubes or in some cases by utilizing both are relied upon to change the very establishments of detecting and distinguishing various analytes. In this review, we will examine the current utilization of functionalized AuNPs and CNTs with other synthetic mixes for the creation of biosensor prompting to the location of particular analytes with low discovery cutoff and quick reaction.
Collapse
Affiliation(s)
- Samiul Alim
- Faculty of Industrial Sciences & Technology, Universiti Malaysia Pahang, Kuantan 26300, Malaysia
| | - Jaya Vejayan
- Faculty of Industrial Sciences & Technology, Universiti Malaysia Pahang, Kuantan 26300, Malaysia
| | - Mashitah M Yusoff
- Faculty of Industrial Sciences & Technology, Universiti Malaysia Pahang, Kuantan 26300, Malaysia
| | - A K M Kafi
- Faculty of Industrial Sciences & Technology, Universiti Malaysia Pahang, Kuantan 26300, Malaysia.
| |
Collapse
|
31
|
Vukojević V, Djurdjić S, Ognjanović M, Fabián M, Samphao A, Kalcher K, Stanković DM. Enzymatic glucose biosensor based on manganese dioxide nanoparticles decorated on graphene nanoribbons. J Electroanal Chem (Lausanne) 2018. [DOI: 10.1016/j.jelechem.2018.07.013] [Citation(s) in RCA: 53] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
32
|
Kausaite-Minkstimiene A, Glumbokaite L, Ramanaviciene A, Dauksaite E, Ramanavicius A. An Amperometric Glucose Biosensor Based on Poly (Pyrrole-2-Carboxylic Acid)/Glucose Oxidase Biocomposite. ELECTROANAL 2018. [DOI: 10.1002/elan.201800044] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Affiliation(s)
- Asta Kausaite-Minkstimiene
- NanoTechnas - Centre of Nanotechnology and Material Science, Institute of Chemistry, Faculty of Chemistry and Geosciences; Vilnius University; Naugarduko str. 24 LT-03225 Vilnius Lithuania
- Department of Immunology; State Research Institute Centre for Innovative Medicine; Santariskiu str. 5 LT-08406 Vilnius Lithuania
| | - Laura Glumbokaite
- NanoTechnas - Centre of Nanotechnology and Material Science, Institute of Chemistry, Faculty of Chemistry and Geosciences; Vilnius University; Naugarduko str. 24 LT-03225 Vilnius Lithuania
| | - Almira Ramanaviciene
- NanoTechnas - Centre of Nanotechnology and Material Science, Institute of Chemistry, Faculty of Chemistry and Geosciences; Vilnius University; Naugarduko str. 24 LT-03225 Vilnius Lithuania
| | - Elena Dauksaite
- NanoTechnas - Centre of Nanotechnology and Material Science, Institute of Chemistry, Faculty of Chemistry and Geosciences; Vilnius University; Naugarduko str. 24 LT-03225 Vilnius Lithuania
| | - Arunas Ramanavicius
- Department of Physical Chemistry, Institute of Chemistry, Faculty of Chemistry and Geosciences; Vilnius University; Naugarduko str. 24 LT-03225 Vilnius Lithuania
- Laboratory of NanoTechnology, Institute of Semiconductor Physics; State Research Institute Centre for Physical and Technological Sciences; A. Gostautog. 11 LT-01108 Vilnius Lithuania
| |
Collapse
|