1
|
Pei S, Lan B, Bai X, Liu Y, Li X, Wang C. Electropolymerization of s-Triazines and Their Charge Storage Performance in Aqueous Acidic Electrolytes. Polymers (Basel) 2024; 16:3266. [PMID: 39684012 DOI: 10.3390/polym16233266] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2024] [Revised: 11/04/2024] [Accepted: 11/05/2024] [Indexed: 12/18/2024] Open
Abstract
Designing novel π-conjugated conductive polymers with abundant redox-active groups is a viable route to achieve high charge storage performance for aqueous energy storage devices. Electropolymerization is a powerful tool to construct conductive polymers. Here, s-triazine is, for the first time, electropolymerized in an aqueous acidic solution on carbon cloth. The polytriazine-coated carbon cloth electrode (PT/CC) exhibits a granular structure, with abundant pores. The charge storage performance is investigated, and a specific capacity of 101.4 mAh g-1 at 1 A g-1 in 1 M H2SO4 is achieved. Additionally, in 1 M ZnSO4, a specific capacity of 50.3 mAh g-1 at 1 A g-1 can be achieved by the PT/CC. The PT/CC behaves as a battery-type charge storage electrode, and the amino/imino and carbonyl/hydroxyl groups contribute to the charge storage, with cation insertion and extraction. A symmetric aqueous charge storage device assembled with two PT/CC electrodes exhibits an energy density of 12.92 Wh kg-1 and a power density of 250 W kg-1 at 1 A g-1. After 2500 cycles at 10 A g-1, the device retains a specific capacity of 83.3%. This study indicates that the PT is a potential candidate material for an aqueous energy storage device.
Collapse
Affiliation(s)
- Shaotong Pei
- Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense, North China Electric Power University, Baoding 071003, China
| | - Bo Lan
- Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense, North China Electric Power University, Baoding 071003, China
| | - Xueting Bai
- Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense, North China Electric Power University, Baoding 071003, China
| | - Yunpeng Liu
- Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense, North China Electric Power University, Baoding 071003, China
| | - Xinyang Li
- Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense, North China Electric Power University, Baoding 071003, China
| | - Chao Wang
- Department of Chemistry and Chemical Engineering, Shaanxi University of Science and Technology, Xi'an 710021, China
| |
Collapse
|
2
|
Li Y, Cheng H. Microfluidic point-of-care testing device for multiplexed detection of liver function blood markers. BIOMEDICAL OPTICS EXPRESS 2024; 15:5803-5817. [PMID: 39421784 PMCID: PMC11482181 DOI: 10.1364/boe.533855] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/09/2024] [Revised: 08/15/2024] [Accepted: 08/15/2024] [Indexed: 10/19/2024]
Abstract
In this work, we developed a novel microfluidic paper-based analytical device to quantify the blood markers of liver function from human fingertips and whole blood samples. The device can quickly acquire information for screening liver injury and supporting clinical decision-making by simultaneously performing quantitative tests for alanine aminotransferase, aspartate aminotransferase, and albumin. We evaluated the detection accuracy and the storage stability of the device using fingertip samples. The yielded results of our device correlated well with those from Mindray BS350s, even under the conditions of 35 °C and 90%RH. Thus, it offers an effective platform for clinical assessment of liver injury particularly in resource-limited areas.
Collapse
Affiliation(s)
- Yingchun Li
- School of Optics and Photonics, Beijing Institute of Technology, Beijing 100000, China
- Dept. of IVD, Jiangsu Konsung Bio-medical Science and Technology Co., Ltd, Jiangsu 212300, China
| | - Haobo Cheng
- School of Optics and Photonics, Beijing Institute of Technology, Beijing 100000, China
| |
Collapse
|
3
|
Kanagavalli P, Eissa S. Exploring various carbon nanomaterials-based electrodes modified with polymelamine for the reagentless electrochemical immunosensing of Claudin18.2. Biosens Bioelectron 2024; 259:116388. [PMID: 38761744 DOI: 10.1016/j.bios.2024.116388] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Revised: 05/06/2024] [Accepted: 05/13/2024] [Indexed: 05/20/2024]
Abstract
Claudin18.2 (CLDN18.2) is a tight junction protein often overexpressed in various solid tumors, including gastrointestinal and esophageal cancers, serving as a promising target and potential biomarker for tumor diagnosis, treatment assessment, and prognosis. Despite its significance, no biosensor has been reported to date for the detection of CLDN18.2. Here, we present the inaugural immunosensor for CLDN18.2. In this study, an amine-rich conducting polymer of polymelamine (PM) was electrografted onto different carbon nanomaterial-based screen-printed electrodes (SPEs), including carbon (C), graphene (Gr), graphene oxide (GO), carbon nanotube (CNT), and carbon nanofiber (CNF) via cyclic voltammetry. A comparative study was performed to explore the best material for the preparation of the PM-modified electrodes to be used as in-situ redox substrate for the immunosensor fabrication. The surface chemistry and structural features of pristine and PM-deposited electrodes were analyzed using Raman and scanning electron microscopy (SEM) techniques. Our results showed that the PM deposited on Gr and CNT/SPEs exhibited the most significant and stable redox behavior in PBS buffer. The terminal amine moieties on the PM-modified electrode surfaces were utilized for immobilizing anti-CLDN18.2 monoclonal antibodies via N-ethyl-N'-(3-(dimethylamino)propyl)carbodiimide/N-hydroxysuccinimide chemistry to construct the electrochemical immunosensor platform. Differential pulse voltammetry-based immunosensing of CLDN18.2 protein on BSA/anti-CLDN18.2/PM-Gr/SPE and BSA/anti-CLDN18.2/PM-CNT/SPE exhibited excellent selectivity against other proteins such as CD1, PDCD1, and ErBb2. The limits of detection of these two immunosensor platforms were calculated to be 7.9 pg/mL and 0.104 ng/mL for the CNT and Gr immunosensors, respectively. This study demonstrated that the PM-modified Gr and CNT electrodes offer promising platforms not only for the reagentless signaling but also for covalent immobilization of biomolecules. Moreover, these platforms offer excellent sensitivity and selectivity for the detection of CLDN18.2 due to its enhanced stable redox activity. The immunosensor demonstrated promising results for the sensitive detection of CLDN18.2 in biological samples, addressing the critical need for early gastric cancer diagnosis.
Collapse
Affiliation(s)
- Pandiyaraj Kanagavalli
- Department of Chemistry, Khalifa University of Science and Technology, Abu Dhabi, P.O. Box 127788, United Arab Emirates
| | - Shimaa Eissa
- Department of Chemistry, Khalifa University of Science and Technology, Abu Dhabi, P.O. Box 127788, United Arab Emirates; Center for Catalysis and Separations, Khalifa University of Science and Technology, Abu Dhabi, P.O. Box 127788, United Arab Emirates.
| |
Collapse
|
4
|
Kanagavalli P, Eissa S. Redox probe-free electrochemical immunosensor utilizing electropolymerized melamine on reduced graphene oxide for the point-of-care diagnosis of gastric cancer. Talanta 2024; 270:125549. [PMID: 38157735 DOI: 10.1016/j.talanta.2023.125549] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Revised: 12/06/2023] [Accepted: 12/11/2023] [Indexed: 01/03/2024]
Abstract
Pepsinogen I (PG I) is a biomarker that plays a crucial role in the diagnosis of gastric cancer. The development of biosensor to monitor PG I overexpression in serum is crucial for early gastric cancer diagnosis, offering a less invasive alternative to the costly and uncomfortable gastroscopy procedure. This study presents a cost-efficient, scalable and disposable label-free biosensing strategy for detecting PG I, utilizing a redox-active polymelamine electrodeposited on a reduced graphene oxide screen-printed electrode surface (PM-rGO/SPE). Under optimized conditions, the conducting polymer PM was deposited on the rGO/SPE via a potentiodynamic method. The structural and morphological features of PM-rGO/SPE were analyzed with the assistance of Raman and Scanning Electron Microscopy analysis. Specific monoclonal anti-PG I antibodies were immobilized on the in situ prepared redox-active layer via EDC/NHS chemistry to develop a novel electrochemical immunosensor. Unlike the traditional immunosensing strategies which utilizes external redox probe solution for measuring the signal, the developed configuration allowed for redox-probe free monitoring of current changes of the redox active PM resulting from the formation of the immunocomplex on the electrode surface. Utilizing this method, PG I detection spanned a clinically relevant concentration range of 0.01-200 ng/mL, with a low limit of detection at 9.1 pg/mL. The electrochemical immunosensor demonstrated specificity against other biomarkers such as PDCD1, ErBb2, and CD28 with negligible interference. The immunosensor exhibited excellent recovery capabilities for PG I detection in serum samples. These findings underscore the potential of the PM-rGO/SPE immunosensor as a point-of-care diagnostic tool for gastric cancer.
Collapse
Affiliation(s)
- Pandiyaraj Kanagavalli
- Department of Chemistry, Khalifa University of Science and Technology, Abu Dhabi, P.O. Box 127788, United Arab Emirates
| | - Shimaa Eissa
- Department of Chemistry, Khalifa University of Science and Technology, Abu Dhabi, P.O. Box 127788, United Arab Emirates; Advanced Materials Chemistry Center (AMCC), Khalifa University of Science and Technology, Abu Dhabi, P.O. Box 127788, United Arab Emirates.
| |
Collapse
|
5
|
Antherjanam S, Saraswathyamma B, Murugesan Senthil Kumar S. Simultaneous electrochemical determination of the tumour biomarkers homovanillic acid and vanillylmandelic acid using a modified pencil graphite electrode. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108659] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/30/2023]
|
6
|
Antherjanam S, Saraswathyamma B. Electrochemical preparation and the characterizations of poly(3,5-diamino 1,2,4-triazole) film for the selective determination of pyridoxine in pharmaceutical formulations. CHEMICKE ZVESTI 2023; 77:1-12. [PMID: 37362795 PMCID: PMC10027263 DOI: 10.1007/s11696-023-02777-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Accepted: 03/10/2023] [Indexed: 03/28/2023]
Abstract
This work describes the synthesis and characterization of a polymeric film of 3,5-diamino 1,2,4-triazole on a pencil graphite electrode for the selective sensing of pyridoxine (PY). The PGE was modified using the electropolymerization process by the potentiodynamic method. The polymerized electrode (PDAT/PGE) was characterized by IR, SEM, AFM, cyclic voltammetry, and electrochemical impedance spectroscopy. PY undergoes irreversible oxidation at 0.79 V on PDAT/PGE in phosphate buffer of pH 5. Using the differential pulse voltammetric technique (DPV), PY showed a linear range from 5 to 950 μM with a lower detection limit of 2.96 μM. The PDAT/PGE was applied for the analytical determination of PY in pharmaceutical tablets with good recovery. Graphical abstract Supplementary Information The online version contains supplementary material available at 10.1007/s11696-023-02777-5.
Collapse
Affiliation(s)
- Santhy Antherjanam
- Department of Chemistry, Amrita Vishwa Vidyapeetham, Amritapuri, Kollam, 690525 India
| | - Beena Saraswathyamma
- Department of Chemistry, Amrita Vishwa Vidyapeetham, Amritapuri, Kollam, 690525 India
| |
Collapse
|
7
|
Kanagavalli P, Natchimuthu Karuppusamy M, Ganesan VS, Saravanan HP, Palanisamy T, Veerapandian M. Electropolymerized Melamine on Electrochemically Reduced Graphene Oxide: Growth Mechanistics, Electrode Processing, and Amperometric Sensing of Acyclovir. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2023; 39:3512-3525. [PMID: 36820624 DOI: 10.1021/acs.langmuir.3c00128] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Metal-free, cost-efficient, redox-active electrode materials, combining graphene derivatives with nitrogen-rich polymelamine (PM), are widely explored as an interface layer for electrocatalysis and an electrochemical sensor platform. However, conventional chemical routes often yield derivatives of PM suffering from impaired redox behavior, restricting their electron-transfer kinetics. Herein, an optimal potentiodynamic method has been established to electrodeposit PM on electrochemically reduced graphene oxide (ErGO). A supporting electrolyte, containing Cl-, enhances the formation of intermediates NH3+ and ═NH2+ at the monomeric melamine, eventually interacting with the residual oxygenated functional groups of ErGO to form PM. In situ Raman spectrum analysis revealed the influence of the defective area and the graphitization ratio on the ErGO surface during the course of electropolymerization of melamine. Under optimal electrodeposition conditions (E = 0-1.6 V; ν = 0.1 V/s), the amount of electrodeposited PM on the ErGO surface was determined to be 16.5 μg/(cycle·cm2), using electrochemical quartz crystal microbalance analysis. An ErGO-PM-modified glassy carbon electrode (GCE) and a screen-printed electrode exhibit the direct electrooxidation of acyclovir (ACV). Amperometric analyses of ErGO-PM-modified electrodes exhibited the lowest detection limit of 137.4 pM with analytical robustness, rapid steady state, and reproducibility promising for ACV detection in complex biological matrices.
Collapse
Affiliation(s)
- Pandiyaraj Kanagavalli
- Electrodics and Electrocatalysis Division, CSIR-Central Electrochemical Research Institute (CECRI), Karaikudi, Tamil Nadu 630003, India
- Academy of Scientific & Innovative Research (AcSIR), Ghaziabad, Uttar Pradesh 201002, India
| | - Murugasenapathi Natchimuthu Karuppusamy
- Electrodics and Electrocatalysis Division, CSIR-Central Electrochemical Research Institute (CECRI), Karaikudi, Tamil Nadu 630003, India
- Academy of Scientific & Innovative Research (AcSIR), Ghaziabad, Uttar Pradesh 201002, India
| | - Veka Sri Ganesan
- Centre for Education (CFE), CSIR-CECRI, Karaikudi, Tamil Nadu 630003, India
| | | | - Tamilarasan Palanisamy
- Electrodics and Electrocatalysis Division, CSIR-Central Electrochemical Research Institute (CECRI), Karaikudi, Tamil Nadu 630003, India
- Academy of Scientific & Innovative Research (AcSIR), Ghaziabad, Uttar Pradesh 201002, India
| | - Murugan Veerapandian
- Electrodics and Electrocatalysis Division, CSIR-Central Electrochemical Research Institute (CECRI), Karaikudi, Tamil Nadu 630003, India
- Academy of Scientific & Innovative Research (AcSIR), Ghaziabad, Uttar Pradesh 201002, India
| |
Collapse
|
8
|
Comment on “Electrochemical Characterisation of Polymelamine Electropolymerised in Deep Eutectic Solvents for Selective Detection of Dopamine”. Electrocatalysis (N Y) 2022. [DOI: 10.1007/s12678-022-00785-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
9
|
Chen Y, Qiu C, Zou Z, Ling Y, Gao F, Shao Y, Wang Q. The integration of conductive polymelamine and NiFe hydroxides to boost the electrochemical overall water splitting. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2022.140773] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
10
|
Ma J, Wu W, Xiao X, Feng Y, Hao Y, Zhang J, Liu C, Zhang P, Chen J, Zeng R, Chen S. New insight into electropolymerization of melamine. II: Low onset potential deposition of polymelamine with trace active bromine. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2022.139991] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
11
|
Zhang Z, Li M, Zuo Y, Chen S, Zhuo Y, Lu M, Shi G, Gu H. In Vivo Monitoring of pH in Subacute PD Mouse Brains with a Ratiometric Electrochemical Microsensor Based on Poly(melamine) Films. ACS Sens 2022; 7:235-244. [PMID: 34936337 DOI: 10.1021/acssensors.1c02051] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
In vivo monitoring of cerebral pH is of great significance because its disturbance is related to some pathological processes such as neurodegenerative diseases, for example, Parkinson's disease (PD). In this study, we developed an electrochemical microsensor based on poly(melamine) (PMel) films for ratiometric monitoring of pH in subacute PD mouse brains. In this microsensor, PMel films were prepared from a simple electropolymerization approach in a melamine-containing solution, serving as the selective pH recognition membrane undergoing a 2H+/2e- process. Meanwhile, electrochemically oxidized graphene oxide (EOGO) produced a built-in correction signal which helped avoid the environmental interference of the complicated brain systems. The potential difference between the peaks generated from EOGO and PMel gradually decreased with the aqueous pH increasing from 4.0 to 9.0, constituting the detection foundation of the ratiometric electrochemical microsensor (REM). The in vitro studies demonstrated that this proposed method exhibited a high sensitivity (a Nernstian response of -61.35 mV/pH) and remarkable selectivity against amino acids, anions, cations, and biochemical and reactive oxygen species coexisting in the brain. Coupled with its excellent stability and reproducibility and good antibiofouling based on short-term detection, the developed REM could serve as a disposable sensor for the determination of cerebral pH in vivo. Its following successful application in the real-time measurement of pH in the striatum, hippocampus, and cortex of rat brains in the events of global cerebral ischemia/reperfusion verified the reliability of this method. Finally, we adopted this robust REM to systematically analyze and compare the average pH in different regions of normal and subacute PD mouse brains.
Collapse
Affiliation(s)
- Ziyi Zhang
- A Key Laboratory of Theoretical Organic Chemistry and Functional Molecule of Ministry of Education, School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan, Hunan 411201, P. R. China
| | - Mengyin Li
- A Key Laboratory of Theoretical Organic Chemistry and Functional Molecule of Ministry of Education, School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan, Hunan 411201, P. R. China
| | - Yimei Zuo
- A Key Laboratory of Theoretical Organic Chemistry and Functional Molecule of Ministry of Education, School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan, Hunan 411201, P. R. China
| | - Shu Chen
- A Key Laboratory of Theoretical Organic Chemistry and Functional Molecule of Ministry of Education, School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan, Hunan 411201, P. R. China
| | - Yi Zhuo
- The National & Local Joint Engineering Laboratory of Animal Peptide Drug Development, Hunan Provincial Key Laboratory of Neurorestoratology, College of Life Sciences, Hunan Normal University, Changsha, Hunan 410006, P.R. China
| | - Ming Lu
- The National & Local Joint Engineering Laboratory of Animal Peptide Drug Development, Hunan Provincial Key Laboratory of Neurorestoratology, College of Life Sciences, Hunan Normal University, Changsha, Hunan 410006, P.R. China
| | - Guoyue Shi
- School of Chemistry and Molecular Engineering, Shanghai Key Laboratory for Urban Ecological Processes and Eco-Restoration, East China Normal University, 500 Dongchuan Road, Shanghai 200241, P. R. China
| | - Hui Gu
- A Key Laboratory of Theoretical Organic Chemistry and Functional Molecule of Ministry of Education, School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan, Hunan 411201, P. R. China
| |
Collapse
|
12
|
Electropolymerization as an electrochemical preconcentration approach for the determination of melamine in milk samples. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2021.138897] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
13
|
Tham GX, Subrata A, Fisher AC, Webster RD. Properties of electrochemically copolymerized aniline and melamine on functionalized multiwalled‐carbon nanotube film electrodes. ELECTROCHEMICAL SCIENCE ADVANCES 2021. [DOI: 10.1002/elsa.202100021] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Affiliation(s)
- Guo Xiong Tham
- Division of Chemistry and Biological Chemistry School of Physical and Mathematical Sciences Nanyang Technological University Singapore Singapore
- Cambridge Centre for Advanced Research and Education in Singapore Singapore Singapore
| | - Arnold Subrata
- Division of Chemistry and Biological Chemistry School of Physical and Mathematical Sciences Nanyang Technological University Singapore Singapore
| | - Adrian C. Fisher
- Cambridge Centre for Advanced Research and Education in Singapore Singapore Singapore
- Department of Chemical Engineering and Biotechnology University of Cambridge Cambridge UK
| | - Richard D. Webster
- Division of Chemistry and Biological Chemistry School of Physical and Mathematical Sciences Nanyang Technological University Singapore Singapore
- Cambridge Centre for Advanced Research and Education in Singapore Singapore Singapore
| |
Collapse
|
14
|
Electrochemical Characterization of Melamine Electropolymerized in Deep Eutectic Solvents for Selective Detection of Dopamine. Electrocatalysis (N Y) 2021. [DOI: 10.1007/s12678-021-00648-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
15
|
Olean-Oliveira A, Oliveira Brito GA, Teixeira MFS. Mechanism of Nanocomposite Formation in the Layer-by-Layer Single-Step Electropolymerization of π-Conjugated Azopolymers and Reduced Graphene Oxide: An Electrochemical Impedance Spectroscopy Study. ACS OMEGA 2020; 5:25954-25967. [PMID: 33073122 PMCID: PMC7557956 DOI: 10.1021/acsomega.0c03391] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Accepted: 08/27/2020] [Indexed: 05/11/2023]
Abstract
This work presents a study of the formation mechanism of electrochemically deposited alternating layers of azopolymer and graphene oxide, as well as a systematic study of the physicochemical characteristics of the resulting nanocomposite films by electrochemical impedance spectroscopy. The nanocomposite films were constructed by cyclic electropolymerization, which allowed for the assembly of thin films with alternating azopolymers and reduced graphene oxide (rGO) layers in one step. Morphological characterizations were performed by atomic force microscopy and scanning electron microscopy and verified that the electrodeposition of the poly(azo-BBY) polymeric film occurred during the anodic sweep, and the deposition of graphene oxide sheets took place during the cathodic sweep. By analyzing the electrochemical impedance spectra using equivalent circuit models, variations in the resistance and capacitance values of the system were monitored as a function of the amount of electrodeposited material on the fluorine doped tin oxide electrode. In addition, the interfacial phenomena that occurred during the electroreduction of the rGO sheets were monitored with the same method.
Collapse
Affiliation(s)
- André Olean-Oliveira
- Department
of Chemistry and Biochemistry, School of Science and Technology, Sao Paulo State University (UNESP), Presidente Prudente, São Paulo 19060-900, Brazil
| | - Gilberto A. Oliveira Brito
- Department
of Chemistry, Pontal Institute of Exact and Natural Sciences, Federal University of Uberlândia, Ituiutaba, Minas Gerais 38302-402, Brazil
| | - Marcos F. S. Teixeira
- Department
of Chemistry and Biochemistry, School of Science and Technology, Sao Paulo State University (UNESP), Presidente Prudente, São Paulo 19060-900, Brazil
| |
Collapse
|
16
|
Martin CS, Olean-Oliveira A, Teixeira MF. A new polymeric thin film by using electropolymerization: thin film of poly(phenazine-salen) obtained from 2,2'-[1,2-ethanediylbis(nitrilomethylidyne)] -bis[4-amino-phenol]. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114404] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
17
|
Decorating the carbon felt electrode with polymeric platinize nanocomposite: characterization and electrocatalytic activity towards methanol oxidation reaction. J CHEM SCI 2019. [DOI: 10.1007/s12039-019-1640-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
|
18
|
Liu F, Yang X, Dang D, Tian X. Engineering of Hierarchical and Three‐Dimensional Architectures Constructed by Titanium Nitride Nanowire Assemblies for Efficient Electrocatalysis. ChemElectroChem 2019. [DOI: 10.1002/celc.201900252] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Fangfang Liu
- Shandong Peninsula Engineering Research Center of Comprehensive Brine UtilizationWeifang University of Science and Technology Shouguang, Weifang 262700 China
| | - Xu Yang
- School of Chemical Engineering and Light IndustryGuangdong University of Technology Guangzhou 510006 China
- School of Chemistry and Chemical EngineeringHunan University of Science and Technology Xiangtan 411201 China
| | - Dai Dang
- School of Chemical Engineering and Light IndustryGuangdong University of Technology Guangzhou 510006 China
- Key Laboratory of Fuel Cell Technology of Guangdong Province Guangzhou 510640 China
| | - Xinlong Tian
- Key Laboratory of Fuel Cell Technology of Guangdong Province Guangzhou 510640 China
- State Key Laboratory of Marine Resource Utilization in South China SeaHainan University Haikou 570228 China
| |
Collapse
|
19
|
Moed S, Zaman MH. A quantitative electrochemical assay for liver injury. Biosens Bioelectron 2019; 131:74-78. [PMID: 30826653 DOI: 10.1016/j.bios.2019.02.032] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2018] [Revised: 01/25/2019] [Accepted: 02/01/2019] [Indexed: 10/27/2022]
Abstract
Liver diseases represent a vastly underestimated and historically neglected public health problem, disproportionately affecting those in low- and middle- income countries (LMICs). Patients on hepatotoxic medications, such as HIV and TB medications, need consistent monitoring of liver function as part of their standard of care. In high resource settings, this is often the case, but in LMICs traditional methods fail due to high cost and lack of proper equipment, supplies and trained personnel. To address this gap in technology and patient care, we have developed a quantitative, electrochemical assay capable of quantifying levels of alanine aminotransferase (ALT), a primary biomarker associated with liver function. We can quantify ALT with increased sensitivity (1.53 nA/(U/L*mm2) and over a wide, linear concentration range (40-1990 U/L). The assay demonstrated in this study can be used to overcome several pressing challenges associated with effective, timely treatment of liver disease in LMICs.
Collapse
Affiliation(s)
- Saundria Moed
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, United States.
| | - Muhammad H Zaman
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, United States; Howard Hughes Medical Institute, Boston University, Boston, MA 02215, United States.
| |
Collapse
|