• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4604935)   Today's Articles (4503)   Subscriber (49371)
For: González-Albarrán R, de Gyves J, Rodríguez de San Miguel E. Influence of some physicochemical parameters on the passive sampling of copper (II) from aqueous medium using a polymer inclusion membrane device. Environ Pollut 2020;258:113474. [PMID: 31859125 DOI: 10.1016/j.envpol.2019.113474] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2019] [Revised: 10/02/2019] [Accepted: 10/22/2019] [Indexed: 06/10/2023]
Number Cited by Other Article(s)
1
Macías M, Jiménez JA, Rodríguez de San Miguel E, Moreira-Santos M. Appraisal on the role of passive sampling for more integrative frameworks on the environmental risk assessment of contaminants. CHEMOSPHERE 2023;324:138352. [PMID: 36898436 DOI: 10.1016/j.chemosphere.2023.138352] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 02/20/2023] [Accepted: 03/07/2023] [Indexed: 06/18/2023]
2
Nitti F, Almeida MIG, Morrison R, Cattrall RW, Pettigrove VJ, Coleman RA, Kolev SD. Flow-through passive sampler for zinc in freshwaters free from flow pattern, water cationic composition and temperature effects. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
3
Olasupo A, Ahmed N, Kamil WMWA, Suah FBM. Enhanced removal of sulfamethoxazole antibiotics from aquatic samples by electromembrane extraction process. REACT FUNCT POLYM 2022. [DOI: 10.1016/j.reactfunctpolym.2022.105211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
4
Sensing Cd(II) Using a Disposable Optical Sensor Based on a Schiff Base Immobilisation on a Polymer-Inclusion Membrane. Applications in Water and Art Paint Samples. Polymers (Basel) 2021;13:polym13244414. [PMID: 34960965 PMCID: PMC8708667 DOI: 10.3390/polym13244414] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 12/03/2021] [Accepted: 12/10/2021] [Indexed: 11/24/2022]  Open
5
Maiphetlho K, Chimuka L, Tutu H, Richards H. Technical design and optimisation of polymer inclusion membranes (PIMs) for sample pre-treatment and passive sampling - A review. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021;799:149483. [PMID: 34426342 DOI: 10.1016/j.scitotenv.2021.149483] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/18/2021] [Revised: 07/14/2021] [Accepted: 08/01/2021] [Indexed: 06/13/2023]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA