1
|
Akturk Y, Simsir BD, Hekimoğlu B. Measurement of Optic Nerve Sheath Diameter by Computed Tomography in the Pediatric Population: Normal Values. J Pediatr Ophthalmol Strabismus 2024; 61:38-43. [PMID: 37092660 DOI: 10.3928/01913913-20230331-02] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/25/2023]
Abstract
PURPOSE To determine the normal values of optic nerve sheath diameter (ONSD) by computed tomography (CT) in the pediatric population. METHODS The CT scans of pediatric patients aged 1 to 16 years who underwent brain CT for different reasons, who did not have intracranial pathology or increased intracranial pressure, and who had no pathology on CT were included in the study. Four age groups were defined with the following ranges: 1 to 2, 3 to 6, 7 to 10, and 11 to 16 years. ONSD was measured from axial CT images, 3 and 10 mm behind the optic globe. RESULTS The normative values of ONSD measured on CT imaging in children aged 1 to 16 years were reported. The change in ONSD according to age was investigated. ONSD was found to increase with age at both levels measured. The difference was statistically significant. CONCLUSIONS Normal values should be known to detect pathologies that may cause an increase in optic nerve diameter. The values reported in this study can serve as a reference for normal optic nerve sheath diameter in the pediatric age group. [J Pediatr Ophthalmol Strabismus. 2024;61(1):38-43.].
Collapse
|
2
|
Kneepkens SCM, Marstal K, Polling JR, Jaddoe VWV, Vernooij MW, Poot DHJ, Klaver CCW, Tideman JWL. Eye Size and Shape in Relation to Refractive Error in Children: A Magnetic Resonance Imaging Study. Invest Ophthalmol Vis Sci 2023; 64:41. [PMID: 38153751 PMCID: PMC10756250 DOI: 10.1167/iovs.64.15.41] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Accepted: 11/28/2023] [Indexed: 12/29/2023] Open
Abstract
Purpose The purpose of this study was to determine the association between eye shape and volume measured with magnetic resonance imaging (MRI) and optical biometry and with spherical equivalent (SE) in children. Methods For this study, there were 3637 10-year-old children from a population-based birth-cohort study that underwent optical biometry (IOL-master 500) and T2-weighted MRI scanning (height, width, and volume). Cycloplegic refractive error was determined by automated refraction. The MRI images of the eyes were segmented using an automated algorithm combining atlas registration with voxel classification. Associations among optical biometry, anthropometry, MRI measurements, and RE were tested using Pearson correlation. Differences between refractive error groups were tested using ANOVA. Results The mean volume of the posterior segment was 6350 (±680) mm3. Myopic eyes (SE ≤ -0.5 diopters [D]) had 470 mm3 (P < 0.001) and 970 mm3 (P < 0.001) larger posterior segment volume than emmetropic and hyperopic eyes (SE ≥ +2.0D), respectively. The majority of eyes (77.1%) had an oblate shape, but 47.4% of myopic eyes had a prolate shape versus 3.9% of hyperopic eyes. The correlation between SE and MRI-derived posterior segment length (r -0.51, P < 0.001) was stronger than the correlation with height (r -0.30, P < 0.001) or width of the eye (r -0.10, P < 0.001). Conclusions In this study, eye shape at 10 years of age was predominantly oblate, even in eyes with myopia. Of all MRI measurements, posterior segment length was most prominently associated with SE. Whether eye shape predicts future myopia development or progression should be investigated in longitudinal studies.
Collapse
Affiliation(s)
- Sander C. M. Kneepkens
- Department of Ophthalmology, Erasmus University Medical Center, Rotterdam, The Netherlands
- Department of Epidemiology, Erasmus University Medical Center, Rotterdam, The Netherlands
- The Generation R Study Group, Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Kasper Marstal
- Department of Ophthalmology, Erasmus University Medical Center, Rotterdam, The Netherlands
- Department of Medical Informatics, Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Jan-Roelof Polling
- Department of Ophthalmology, Erasmus University Medical Center, Rotterdam, The Netherlands
- Department of Orthoptics, School of Applied Science Utrecht, Utrecht, The Netherlands
| | - Vincent W. V. Jaddoe
- The Generation R Study Group, Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Meike W. Vernooij
- Department of Epidemiology, Erasmus University Medical Center, Rotterdam, The Netherlands
- Department of Radiology, Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Dirk H. J. Poot
- Department of Medical Informatics, Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Caroline C. W. Klaver
- Department of Ophthalmology, Erasmus University Medical Center, Rotterdam, The Netherlands
- Department of Epidemiology, Erasmus University Medical Center, Rotterdam, The Netherlands
- The Generation R Study Group, Erasmus University Medical Center, Rotterdam, The Netherlands
- Department of Ophthalmology, Radboud University Medical Center, Nijmegen, The Netherlands
- Institute of Molecular and Clinical Ophthalmology, Basel, Switzerland
| | - J. Willem L. Tideman
- Department of Ophthalmology, Erasmus University Medical Center, Rotterdam, The Netherlands
- The Generation R Study Group, Erasmus University Medical Center, Rotterdam, The Netherlands
| |
Collapse
|
3
|
Silverman RH. Principles of Ophthalmic Ultrasound. EXPERT REVIEW OF OPHTHALMOLOGY 2023; 18:379-389. [PMID: 38370284 PMCID: PMC10871633 DOI: 10.1080/17469899.2023.2277781] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Accepted: 10/27/2023] [Indexed: 02/20/2024]
Abstract
Introduction Ultrasound imaging of the eye was introduced over 50 years ago. While the physical principles of ultrasound imaging have not changed, technology has undergone tremendous and ongoing development. Areas covered The fundamentals of ultrasound physics, biometry (A-scan), structural imaging (B-scan) and blood-flow imaging and measurement (Doppler) will be described. Emphasis will be placed on technological development and potential future advances. Expert opinion While A- and B-scan ultrasound of the eye has traditionally been performed with focused single-element transducers, the introduction of annular and linear arrays has enhanced clinical utility. Future advances, especially in multielement arrays, and point-of-care systems promise amazing new capabilities for diagnostic imaging of the eye and orbit.
Collapse
|
4
|
Jaarsma-Coes MG, Klaassen L, Marinkovic M, Luyten GPM, Vu THK, Ferreira TA, Beenakker JWM. Magnetic Resonance Imaging in the Clinical Care for Uveal Melanoma Patients-A Systematic Review from an Ophthalmic Perspective. Cancers (Basel) 2023; 15:cancers15112995. [PMID: 37296958 DOI: 10.3390/cancers15112995] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Revised: 05/24/2023] [Accepted: 05/26/2023] [Indexed: 06/12/2023] Open
Abstract
Conversely to most tumour types, magnetic resonance imaging (MRI) was rarely used for eye tumours. As recent technical advances have increased ocular MRI's diagnostic value, various clinical applications have been proposed. This systematic review provides an overview of the current status of MRI in the clinical care of uveal melanoma (UM) patients, the most common eye tumour in adults. In total, 158 articles were included. Two- and three-dimensional anatomical scans and functional scans, which assess the tumour micro-biology, can be obtained in routine clinical setting. The radiological characteristics of the most common intra-ocular masses have been described extensively, enabling MRI to contribute to diagnoses. Additionally, MRI's ability to non-invasively probe the tissue's biological properties enables early detection of therapy response and potentially differentiates between high- and low-risk UM. MRI-based tumour dimensions are generally in agreement with conventional ultrasound (median absolute difference 0.5 mm), but MRI is considered more accurate in a subgroup of anteriorly located tumours. Although multiple studies propose that MRI's 3D tumour visualisation can improve therapy planning, an evaluation of its clinical benefit is lacking. In conclusion, MRI is a complementary imaging modality for UM of which the clinical benefit has been shown by multiple studies.
Collapse
Affiliation(s)
- Myriam G Jaarsma-Coes
- Department of Ophthalmology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
- Department of Radiology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
| | - Lisa Klaassen
- Department of Ophthalmology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
- Department of Radiology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
- Department of Radiation Oncology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
| | - Marina Marinkovic
- Department of Ophthalmology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
| | - Gregorius P M Luyten
- Department of Ophthalmology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
| | - T H Khanh Vu
- Department of Ophthalmology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
| | - Teresa A Ferreira
- Department of Radiology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
| | - Jan-Willem M Beenakker
- Department of Ophthalmology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
- Department of Radiology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
- Department of Radiation Oncology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
| |
Collapse
|
5
|
Streckenbach F, Jäschke M, Jahns N, Langner I, König J, Wree A, Stahnke T, Stachs O, Frank M, Langner S, Lindner T. MR
microscopy of the developing upper extremity of the chicken in ovo using 7 Tesla
MRI. Anat Histol Embryol 2022; 52:356-362. [PMID: 36461880 DOI: 10.1111/ahe.12894] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Accepted: 11/25/2022] [Indexed: 12/04/2022]
Abstract
MR microscopy (MRM) is known as ultra-high-field (UHF) magnetic resonance imaging with an in-plane spatial resolution of <100 μm, yields highly resolved non-invasive anatomical imaging and allows longitudinal assessment of embryonic avian development. The aim of the present study was to evaluate the feasibility of in vivo anatomical MRI assessment of the developing upper extremity of the chicken. Thirty-eight fertilized chicken eggs were examined at 7 Tesla acquiring high-resolution T2-weighted images with an in-plane resolution of 74 × 74 μm. To reduce motion artefacts, the eggs were moderately cooled before and during MRI. Development of the upper extremity was anatomically and quantitatively assessed. Chondrification and ossification on MRI were correlated with histological examination. MRM allowed the identification of the embryo from stage D5 onwards. First chondrification of the upper extremity was visible at stage D7, and the differentiation of the forearm was possible from stage D9 throughout the developmental period with excellent correlation to histology. MRM also allowed the differentiation between cortical and medullary bone as well as the detection of chondrified areas. UHF MRM allows the in vivo and in ovo evaluation of the upper limb during embryonic development and provides non-invasive longitudinal anatomical information. This technique allows longitudinal studies of the same embryo during the developmental period and may therefore provide further insights into the development of the upper extremity. With improved coil technique and increasing availability of UHF MR systems, there is great potential regarding several research topics in experimental musculoskeletal radiology.
Collapse
Affiliation(s)
- Felix Streckenbach
- Institute for Diagnostic and Interventional Radiology, Pediatric and Neuroradiology Rostock University Medical Center Rostock Germany
| | - Malte Jäschke
- Institute for Diagnostic and Interventional Radiology, Pediatric and Neuroradiology Rostock University Medical Center Rostock Germany
| | - Nora Jahns
- Institute for Diagnostic Radiology and Neuroradiology University Medicine Greifswald Greifswald Germany
| | - Inga Langner
- Department of Orthopedics and Orthopaedic Surgery University Medicine Greifswald Greifswald Germany
| | - Julia König
- Department of Anesthesia and Intensive Care University Hospital Rostock Rostock Germany
| | - Andreas Wree
- Institute of Anatomy, Rostock University Medical Center Rostock Germany
| | - Thomas Stahnke
- Department of Ophthalmology Rostock University Medical Center Rostock Germany
- Institute for Implant Technology and Biomaterials‐IIB E.V Associated Institute of the University of Rostock Warnemuende Germany
| | - Oliver Stachs
- Department of Ophthalmology Rostock University Medical Center Rostock Germany
| | - Marcus Frank
- Medical Biology and Electron Microscopy Center Rostock University Medical Center Rostock Germany
- Department Life, Light & Matter University of Rostock Rostock Germany
| | - Sönke Langner
- Institute for Diagnostic and Interventional Radiology, Pediatric and Neuroradiology Rostock University Medical Center Rostock Germany
| | - Tobias Lindner
- Institute for Diagnostic and Interventional Radiology, Pediatric and Neuroradiology Rostock University Medical Center Rostock Germany
- Core Facility Multimodal Small Animal Imaging Rostock University Medical Center Rostock Germany
| |
Collapse
|
6
|
Hassan MK, Fleury E, Shamonin D, Fonk LG, Marinkovic M, Jaarsma-Coes MG, Luyten GP, Webb A, Beenakker JW, Stoel B. An Automatic Framework to Create Patient-specific Eye Models From 3D Magnetic Resonance Images for Treatment Selection in Patients With Uveal Melanoma. Adv Radiat Oncol 2021; 6:100697. [PMID: 34660938 PMCID: PMC8503565 DOI: 10.1016/j.adro.2021.100697] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Revised: 11/26/2020] [Accepted: 03/25/2021] [Indexed: 12/14/2022] Open
Abstract
PURPOSE The optimal treatment strategy for uveal melanoma (UM) relies on many factors, the most important being tumor size and location. Building on recent developments in high-resolution 3D ocular magnetic resonance imaging (MRI), we developed an automatic image-processing framework to create patient-specific eye models and to subsequently determine the full 3D tumor shape and size automatically. METHODS AND MATERIALS From 15 patients with UM, 3D inversion-recovery gradient-echo (T1-weighted) and 3D fat-suppressed spin-echo (T2-weighted) images were acquired with a 7T MRI scanner. First, the sclera and cornea were segmented from the T2-weighted image by mesh-fitting. The T1- and T2-weighted images were then coregistered. From the registered T1-weighted image, the lens, vitreous body, retinal detachment, and tumor were segmented. Fuzzy C-means clustering was used to differentiate the tumor from retinal detachments. The tumor model was verified and (if needed) edited by an ophthalmic MRI specialist. Subsequently, the prominence and largest basal diameter of the tumor were measured automatically based on the verified contours. These results were compared with manual assessments on the original images and with ultrasound measurements to show the errors in manual analysis. RESULTS The framework successfully created an eye model fully automatically in 12 cases. In these cases, a Dice similarity coefficient (mean surface distance) of 97.7%±0.84% (0.17±0.11 mm) was achieved for the sclera, 96.8%±1.05% (0.20±0.06 mm) for the vitreous body, 91.6%±4.83% (0.15±0.06 mm) for the lens, and 86.0%±7.4% (0.35±0.27 mm) for the tumor. The manual assessments deviated, on average, 0.39±0.31 mm in prominence and 1.7±1.22 mm in basal diameter from the automatic measurements. CONCLUSIONS The described framework combined information from T1- and T2-weighted images to accurately determine tumor boundaries in 3D. The proposed process may have a direct effect on clinical workflow, as it enables an accurate 3D assessment of tumor dimensions, which directly influences therapy selection.
Collapse
Affiliation(s)
| | - Emmanuelle Fleury
- Department of Radiation Oncology, Erasmus Medical Center, Rotterdam, The Netherlands
- Department of Radiation Oncology, HollandPTC, Delft, The Netherlands
| | - Denis Shamonin
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Lorna Grech Fonk
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
- Department of Ophthalmology, Leiden University Medical Center, Leiden, The Netherlands
| | - Marina Marinkovic
- Department of Ophthalmology, Leiden University Medical Center, Leiden, The Netherlands
| | - Myriam G. Jaarsma-Coes
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
- Department of Ophthalmology, Leiden University Medical Center, Leiden, The Netherlands
| | - Gregorius P.M. Luyten
- Department of Ophthalmology, Leiden University Medical Center, Leiden, The Netherlands
| | - Andrew Webb
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Jan-Willem Beenakker
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
- Department of Ophthalmology, Leiden University Medical Center, Leiden, The Netherlands
| | - Berend Stoel
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
7
|
Tang MCY, Jaarsma-Coes MG, Ferreira TA, Zwirs-Grech Fonk L, Marinkovic M, Luyten GPM, Beenakker JWM. A Comparison of 3 T and 7 T MRI for the Clinical Evaluation of Uveal Melanoma. J Magn Reson Imaging 2021; 55:1504-1515. [PMID: 34652049 PMCID: PMC9293452 DOI: 10.1002/jmri.27939] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2021] [Revised: 09/16/2021] [Accepted: 09/18/2021] [Indexed: 12/22/2022] Open
Abstract
Background Magnetic resonance imaging (MRI) is increasingly being used in the diagnosis and treatment planning of uveal melanoma (UM), the most common primary intraocular tumor. Initially, 7 T MRI was primarily used, but more recently these techniques have been translated to 3 T, as it is more commonly available. Purpose Compare the diagnostic performance of 3 T and 7 T MRI of UM. Study Type Prospective. Population Twenty‐seven UM patients (19% female). Field Strength/Sequence 3 T: T1‐ and T2‐weighted three‐dimensional (3D) spin echo (SE) and multi‐slice (MS) SE, 7 T: T1‐weighted 3D gradient echo (GE), T2‐weighted 3D SE and MS SE, 3 T and 7 T GE dynamic contrast‐enhanced. T1 weighted images: acquired before and after Gadolinium (Gd) administration. Assessment For all sequences, scan and diagnostic quality was quantified using a 5‐point Likert scale. Signal intensities on T1 and T2 relative to choroid and eye muscle respectively were assessed as well as the tumor prominence. Finally, the perfusion time‐intensity curves (TICs) were classified as plateau, progressive, or wash‐out. Statistical Tests Image quality scores were compared between both field strengths using Wilcoxon signed‐rank and McNemar tests. Paired t‐tests and Bland–Altman were used for comparing tumor prominences. P < 0.05 was considered statistically significant. Results Image quality was comparable between 3 T and 7 T, for 3DT1, 3DT2, 3DT1Gd (P = 0.86; P = 0.34; P = 0.78, respectively) and measuring tumor dimensions (P = 0.40). 2DT1 and 2DT2 image quality were rated better on 3 T compared to 7 T. Most UM had the same relative signal intensities at 3 T and 7 T on T1 (17/21) and T2 (13/17), and 16/18 diagnostic TICs received the same classification. Tumor prominence measurements were similar between field strengths (95% confidence interval: −0.37 mm to 0.03 mm, P = 0.097). Data Conclusion Diagnostic performance of the evaluated 3 T protocol proved to be as capable as 7 T, with the addition of 3 T being superior in assessing tumor growth into nearby anatomical structures compared to 7 T. Level of Evidence 2 Technical Efficacy Stage 3
Collapse
Affiliation(s)
- Michael C Y Tang
- Department of Ophthalmology, Leiden University Medical Center, Leiden, The Netherlands.,Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Myriam G Jaarsma-Coes
- Department of Ophthalmology, Leiden University Medical Center, Leiden, The Netherlands.,Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Teresa A Ferreira
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Lorna Zwirs-Grech Fonk
- Department of Ophthalmology, Leiden University Medical Center, Leiden, The Netherlands.,Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Marina Marinkovic
- Department of Ophthalmology, Leiden University Medical Center, Leiden, The Netherlands
| | - Gregorius P M Luyten
- Department of Ophthalmology, Leiden University Medical Center, Leiden, The Netherlands
| | - Jan-Willem M Beenakker
- Department of Ophthalmology, Leiden University Medical Center, Leiden, The Netherlands.,Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
8
|
Tanenbaum RE, Lobo R, Kahana A, Wester ST. Advances in magnetic resonance imaging of orbital disease. Can J Ophthalmol 2021; 57:217-227. [PMID: 34058140 PMCID: PMC8627536 DOI: 10.1016/j.jcjo.2021.04.025] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Revised: 03/16/2021] [Accepted: 04/28/2021] [Indexed: 01/14/2023]
Abstract
Magnetic resonance imaging (MRI) is increasingly used by the orbital surgeon to aid in the diagnosis, surgical planning, and monitoring of orbital disease. MRI provides superior soft tissue detail compared with computed tomography or ultrasound, and advancing techniques enhance its ability to highlight abnormal orbital pathology. Diffusion-weighted imaging is a specialized technique that uses water molecule diffusion patterns in tissue to generate contrast signals and can help distinguish malignant from benign lesions. Steady-state free precession sequences such as Constructive Interference in Steady-State (CISS) and Fast Imaging Employing Steady-state Acquisition (FIESTA) generate highly detailed, 3-dimensional reconstructed images and are particularly useful in distinguishing structures adjacent to cerebral spinal fluid. Magnetic resonance angiography can be used to characterize vascular lesions within the orbit. New developments in magnetic field strength as well as the use of orbital surface coils achieve increasingly improved imaging resolution.
Collapse
Affiliation(s)
- Rebecca E Tanenbaum
- Bascom Palmer Eye Institute, Department of Ophthalmology, University of Miami Miller School of Medicine, Miami, Florida
| | - Remy Lobo
- Department of Radiology, University of Michigan, Ann Arbor, Michigan
| | - Alon Kahana
- Department of Ophthalmology, Oakland University William Beaumont School of Medicine, Rochester, Michigan; Consultants in Ophthalmic and Facial Plastic Surgery, Southfield, Michigan
| | - Sara T Wester
- Bascom Palmer Eye Institute, Department of Ophthalmology, University of Miami Miller School of Medicine, Miami, Florida.
| |
Collapse
|
9
|
Abstract
Magnetic resonance (MR) imaging is a crucial tool for evaluation of the skull base, enabling characterization of complex anatomy by utilizing multiple image contrasts. Recent technical MR advances have greatly enhanced radiologists' capability to diagnose skull base pathology and help direct management. In this paper, we will summarize cutting-edge clinical and emerging research MR techniques for the skull base, including high-resolution, phase-contrast, diffusion, perfusion, vascular, zero echo-time, elastography, spectroscopy, chemical exchange saturation transfer, PET/MR, ultra-high-field, and 3D visualization. For each imaging technique, we provide a high-level summary of underlying technical principles accompanied by relevant literature review and clinical imaging examples.
Collapse
Affiliation(s)
- Claudia F Kirsch
- Division Chief, Neuroradiology, Professor of Neuroradiology and Otolaryngology, Department of Radiology, Northwell Health, Zucker Hofstra School of Medicine at Northwell, North Shore University Hospital, Manhasset, NY
| | - Mai-Lan Ho
- Associate Professor of Radiology, Director of Research, Department of Radiology, Director, Advanced Neuroimaging Core, Chair, Asian Pacific American Network, Secretary, Association for Staff and Faculty Women, Nationwide Children's Hospital and The Ohio State University, Columbus, OH; Division Chief, Neuroradiology, Professor of Neuroradiology and Otolaryngology, Department of Radiology, Northwell Health, Zucker Hofstra School of Medicine at Northwell, North Shore University Hospital, Manhasset, NY.
| |
Collapse
|
10
|
Niendorf T, Beenakker JWM, Langner S, Erb-Eigner K, Bach Cuadra M, Beller E, Millward JM, Niendorf TM, Stachs O. Ophthalmic Magnetic Resonance Imaging: Where Are We (Heading To)? Curr Eye Res 2021; 46:1251-1270. [PMID: 33535828 DOI: 10.1080/02713683.2021.1874021] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Magnetic resonance imaging of the eye and orbit (MReye) is a cross-domain research field, combining (bio)physics, (bio)engineering, physiology, data sciences and ophthalmology. A growing number of reports document technical innovations of MReye and promote their application in preclinical research and clinical science. Realizing the progress and promises, this review outlines current trends in MReye. Examples of MReye strategies and their clinical relevance are demonstrated. Frontier applications in ocular oncology, refractive surgery, ocular muscle disorders and orbital inflammation are presented and their implications for explorations into ophthalmic diseases are provided. Substantial progress in anatomically detailed, high-spatial resolution MReye of the eye, orbit and optic nerve is demonstrated. Recent developments in MReye of ocular tumors are explored, and its value for personalized eye models derived from machine learning in the treatment planning of uveal melanoma and evaluation of retinoblastoma is highlighted. The potential of MReye for monitoring drug distribution and for improving treatment management and the assessment of individual responses is discussed. To open a window into the eye and into (patho)physiological processes that in the past have been largely inaccessible, advances in MReye at ultrahigh magnetic field strengths are discussed. A concluding section ventures a glance beyond the horizon and explores future directions of MReye across multiple scales, including in vivo electrolyte mapping of sodium and other nuclei. This review underscores the need for the (bio)medical imaging and ophthalmic communities to expand efforts to find solutions to the remaining unsolved problems and technical obstacles of MReye, with the objective to transfer methodological advancements driven by MR physics into genuine clinical value.
Collapse
Affiliation(s)
- Thoralf Niendorf
- MRI.TOOLS GmbH, Berlin, Germany.,Berlin Ultrahigh Field Facility, Max Delbrueck Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Jan-Willem M Beenakker
- Department of Ophthalmology and Department of Radiology, Leiden University Medical Centre, Leiden, The Netherlands
| | - Sönke Langner
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, Rostock University Medical Center, Rostock, Germany
| | - Katharina Erb-Eigner
- Department of Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität Zu Berlin, and Berlin Institute of Health, Berlin, Germany
| | - Meritxell Bach Cuadra
- Center for Biomedical Imaging (CIBM), Lausanne, Switzerland.,Department of Radiology, Lausanne University and University Hospital, Lausanne, Switzerland
| | - Ebba Beller
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, Rostock University Medical Center, Rostock, Germany
| | - Jason M Millward
- Berlin Ultrahigh Field Facility, Max Delbrueck Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | | | - Oliver Stachs
- Department Life, Light & Matter, University Rostock, Rostock, Germany.,Department of Ophthalmology, Rostock University Medical Center, Rostock, Germany
| |
Collapse
|
11
|
Keene KR, van Vught L, van de Velde NM, Ciggaar IA, Notting IC, Genders SW, Verschuuren JJ, Tannemaat MR, Kan HE, Beenakker JM. The feasibility of quantitative MRI of extra-ocular muscles in myasthenia gravis and Graves' orbitopathy. NMR IN BIOMEDICINE 2021; 34:e4407. [PMID: 32893386 PMCID: PMC7757175 DOI: 10.1002/nbm.4407] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Revised: 08/20/2020] [Accepted: 08/20/2020] [Indexed: 05/02/2023]
Abstract
Although quantitative MRI can be instrumental in the diagnosis and assessment of disease progression in orbital diseases involving the extra-ocular muscles (EOM), acquisition can be challenging as EOM are small and prone to eye-motion artefacts. We explored the feasibility of assessing fat fractions (FF), muscle volumes and water T2 (T2water ) of EOM in healthy controls (HC), myasthenia gravis (MG) and Graves' orbitopathy (GO) patients. FF, EOM volumes and T2water values were determined in 12 HC (aged 22-65 years), 11 MG (aged 28-71 years) and six GO (aged 28-64 years) patients at 7 T using Dixon and multi-echo spin-echo sequences. The EOM were semi-automatically 3D-segmented by two independent observers. MANOVA and t-tests were used to assess differences in FF, T2water and volume of EOM between groups (P < .05). Bland-Altman limits of agreement (LoA) were used to assess the reproducibility of segmentations and Dixon scans. The scans were well tolerated by all subjects. The bias in FF between the repeated Dixon scans was -0.7% (LoA: ±2.1%) for the different observers; the bias in FF was -0.3% (LoA: ±2.8%) and 0.03 cm3 (LoA: ± 0.36 cm3 ) for volume. Mean FF of EOM in MG (14.1% ± 1.6%) was higher than in HC (10.4% ± 2.5%). Mean muscle volume was higher in both GO (1.2 ± 0.4 cm3 ) and MG (0.8 ± 0.2 cm3 ) compared with HC (0.6 ± 0.2 cm3 ). The average T2water for all EOM was 24.6 ± 4.0 ms for HC, 24.0 ± 4.7 ms for MG patients and 27.4 ± 4.2 ms for the GO patient. Quantitative MRI at 7 T is feasible for measuring FF and muscle volumes of EOM in HC, MG and GO patients. The measured T2water was on average comparable with skeletal muscle, although with higher variation between subjects. The increased FF in the EOM in MG patients suggests that EOM involvement in MG is accompanied by fat replacement. The unexpected EOM volume increase in MG may provide novel insights into underlying pathophysiological processes.
Collapse
Affiliation(s)
- Kevin R. Keene
- CJ Gorter Center for High Field MRI, Department of RadiologyLeiden University Medical CenterLeidenthe Netherlands
- Department of NeurologyLeiden University Medical CenterLeidenthe Netherlands
| | - Luc van Vught
- CJ Gorter Center for High Field MRI, Department of RadiologyLeiden University Medical CenterLeidenthe Netherlands
- Department of OphthalmologyLeiden University Medical CenterLeidenthe Netherlands
| | | | - Isabeau A. Ciggaar
- CJ Gorter Center for High Field MRI, Department of RadiologyLeiden University Medical CenterLeidenthe Netherlands
- Department of OphthalmologyLeiden University Medical CenterLeidenthe Netherlands
| | - Irene C. Notting
- Department of OphthalmologyLeiden University Medical CenterLeidenthe Netherlands
| | - Stijn W. Genders
- Department of OphthalmologyLeiden University Medical CenterLeidenthe Netherlands
| | - Jan J.G.M. Verschuuren
- Department of NeurologyLeiden University Medical CenterLeidenthe Netherlands
- Duchenne Centerthe Netherlands
| | | | - Hermien E. Kan
- CJ Gorter Center for High Field MRI, Department of RadiologyLeiden University Medical CenterLeidenthe Netherlands
- Duchenne Centerthe Netherlands
| | - Jan‐Willem M. Beenakker
- CJ Gorter Center for High Field MRI, Department of RadiologyLeiden University Medical CenterLeidenthe Netherlands
- Department of OphthalmologyLeiden University Medical CenterLeidenthe Netherlands
| |
Collapse
|
12
|
Grech Fonk L, Ferreira TA, Webb AG, Luyten GPM, Beenakker JWM. The Economic Value of MR-Imaging for Uveal Melanoma. Clin Ophthalmol 2020; 14:1135-1143. [PMID: 32425499 PMCID: PMC7196205 DOI: 10.2147/opth.s238405] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2019] [Accepted: 03/03/2020] [Indexed: 12/12/2022] Open
Abstract
Objective Uveal melanoma (UM) is the most common primary intra-ocular tumour. Treatment is determined by tumour size and location. Generally, smaller tumours are eligible for brachytherapy unless they are located close to posterior pole. Larger tumours are enucleated or undergo proton beam therapy (PBT), which is more expensive than brachytherapy and less available. Accuracy of tumour size determination is critical for accurate planning and delivery of treatment, particularly to ensure tumour coverage, critical structure sparing, and for the choice of treatment modality. This is particularly the case for tumour dimensions that are close to the cut-off point for a specific type of treatment: in the case of the brachytherapy protocol at our institution, 6-8 mm. Ultrasound is conventionally used, but magnetic resonance imaging (MRI) has recently become an additional available tool. Although more expensive, it enables more accurate measurements and is particularly useful in combination with clinical fundus examination, fundus photography and ultrasound. Our aim in this paper was to determine the economic value of MRI for UM treatment. Methods We retrospectively analysed 60 patients' MRI scans acquired as part of a study or for clinical care. For each patient, we assessed whether the extra cost of an MRI generated economic benefit or change in optimal treatment. Results MRI indicated a smaller tumour prominence than US in 10% of patients with intermediate tumour size, resulting in a change from PBT to brachytherapy. The costs of MRI, €200-€1000, are significantly lower than the higher costs of PBT compared to brachytherapy, €24,000 difference. In addition, the annual total economic burden of severe vision impairment associated with eye removal is €10,000. Furthermore, for patients where ultrasound was impossible due to previous surgery, MRI enabled eye-preserving treatment. Conclusion An additional MRI for specific patients with UM improves economic value as it enables less expensive treatment in a sufficient percentage of patients to compensate for the MRI costs. Value is increased in terms of quality of care as it enables for some a treatment option which spares more vision.
Collapse
Affiliation(s)
- Lorna Grech Fonk
- Department of Ophthalmology, Leiden University Medical Centre, Leiden, the Netherlands.,Department of Radiology, Leiden University Medical Centre, Leiden, the Netherlands
| | - Teresa A Ferreira
- Department of Radiology, Leiden University Medical Centre, Leiden, the Netherlands
| | - Andrew G Webb
- Department of Radiology, Leiden University Medical Centre, Leiden, the Netherlands.,C.J. Gorter Centre for High Field Magnetic Resonance Imaging, Department of Radiology, Leiden University Medical Centre, Leiden, the Netherlands
| | - Gregorius P M Luyten
- Department of Ophthalmology, Leiden University Medical Centre, Leiden, the Netherlands
| | - Jan-Willem M Beenakker
- Department of Ophthalmology, Leiden University Medical Centre, Leiden, the Netherlands.,Department of Radiology, Leiden University Medical Centre, Leiden, the Netherlands
| |
Collapse
|
13
|
Jaarsma-Coes MG, Ferreira TA, Luyten GPM, Beenakker JWM. Reaction on "Ocular ultrasound versus MRI in the detection of extrascleral extension in a patient with choroidal melanoma". BMC Ophthalmol 2019; 19:193. [PMID: 31455325 PMCID: PMC6712588 DOI: 10.1186/s12886-019-1206-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2019] [Accepted: 08/20/2019] [Indexed: 02/03/2023] Open
Abstract
BACKGROUND In the recently published article entitled "Ocular ultrasound versus MRI in the detection of extrascleral extension in a patient with choroidal melanoma" Jacobsen et al. describe a case in which a hyper-intense extra-ocular lesion on MRI was erroneously diagnosed as an extrascleral extension of the tumor. Based upon this the authors conclude "the superiority of ocular ultrasound in the diagnostic management of extra scleral extension in choroidal melanoma". In our view, there are numerous flaws in the investigation that cast doubt on this message. MAIN: First of all, this is quite a bold statement when only one patient has been evaluated. Secondly, the manuscript only presents a post-contrast T1-weighted image, whereas multiple MRI-sequences need to be included to determine if a hyperintense region is an extrascleral invasion. Moreover, no modern MRI-techniques such Dynamic Contrast Enhanced (DCE) or Diffusion Weighted Imaging (DWI) have been included in the evaluation of this patient, making it hard to use this single case to compare the efficacy of MRI and Ultrasound. The presented data do, however, give clear clues that the hyperintense lesion is likely to be inflammatory. CONCLUSION Although the study falls short in providing a comprehensive comparison between current MRI techniques and ultrasound, it does show that the evaluation of ocular MR-images should be made in a multi-disciplinary setting involving both ophthalmologist and radiologists, since the field of ocular MRI is continuously progressing.
Collapse
Affiliation(s)
- M G Jaarsma-Coes
- Ophthalmology, Leiden University Medical Center, P.O. 9600, 2300 RC, Leiden, The Netherlands. .,Radiology, C.J. Gorter Center for High Field MRI, Leiden University Medical Center, P.O. 9600, 2300 RC, Leiden, The Netherlands.
| | - T A Ferreira
- Radiology, C.J. Gorter Center for High Field MRI, Leiden University Medical Center, P.O. 9600, 2300 RC, Leiden, The Netherlands
| | - G P M Luyten
- Ophthalmology, Leiden University Medical Center, P.O. 9600, 2300 RC, Leiden, The Netherlands
| | - J W M Beenakker
- Ophthalmology, Leiden University Medical Center, P.O. 9600, 2300 RC, Leiden, The Netherlands.,Radiology, C.J. Gorter Center for High Field MRI, Leiden University Medical Center, P.O. 9600, 2300 RC, Leiden, The Netherlands
| |
Collapse
|
14
|
Ultrahigh-Field Quantitative MR Microscopy of the Chicken Eye In Vivo Throughout the In Ovo Period. Mol Imaging Biol 2019; 21:78-85. [PMID: 29796725 DOI: 10.1007/s11307-018-1208-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
Abstract
PURPOSE Ultrahigh-field MRI (UHF-MRI) with an in-plane spatial resolution of less than 100 μm is known as MR microscopy (MRM). MRM provides highly resolved anatomical images and allows quantitative assessment of different tissue types using diffusion-weighted imaging (DWI). The aim of the present study was to evaluate the feasibility of combined in vivo anatomical and quantitative assessment of the developing chicken eye in ovo. PROCEDURES Thirty-eight fertilized chicken eggs were examined at 7.1 T (ClinScan, Bruker Biospin, Germany) acquiring a dataset comprising T2-weighted anatomical images, DWI, and diffusion tensor imaging. To reduce motion artifacts, the eggs were moderately cooled before and during MR imaging. Two eggs were imaged daily for the entire developmental period, and 36 eggs were examined pairwise at only one time point of the embryonic period. Development of the eye was anatomically and quantitatively assessed. RESULTS From the D5 embryonic stage (116-124 h), MRM allowed differentiation between lens and vitreous body. The lens core and periphery were first identified at D9. DWI allowed quantification of lens maturation based on a significant decrease in apparent diffusion coefficient values and course of fractional anisotropy. Repeated moderate cooling had no influence on the development of the chicken embryo. CONCLUSIONS MRM allows in vivo assessment of embryonic development of the chicken eye in ovo without affecting normal development. The method provides anatomical information supplemented by quantitative evaluation of lens development using DWI. With increasing availability of ultrahigh-field MR systems, this technique may provide a noninvasive complementary tool in the field of experimental ophthalmology.
Collapse
|
15
|
7.1 T MRI and T2 mapping of the human and porcine vitreous body post mortem. Eur J Pharm Biopharm 2018; 131:82-91. [DOI: 10.1016/j.ejpb.2018.07.021] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2018] [Revised: 07/24/2018] [Accepted: 07/25/2018] [Indexed: 12/30/2022]
|
16
|
Lee HC, Lee WJ, Dho YS, Cho WS, Kim YH, Park HP. Optic nerve sheath diameter based on preoperative brain computed tomography and intracranial pressure are positively correlated in adults with hydrocephalus. Clin Neurol Neurosurg 2018; 167:31-35. [PMID: 29433056 DOI: 10.1016/j.clineuro.2018.02.012] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2017] [Revised: 01/11/2018] [Accepted: 02/06/2018] [Indexed: 12/01/2022]
Abstract
OBJECTIVE The usefulness of optic nerve sheath diameter (ONSD) in predicting increased intracranial pressure (ICP) is not well established in adults with hydrocephalus. In this retrospective study, we evaluated the correlation between ONSD measured on brain computed tomography (CT) and ICP in adults with hydrocephalus. PATIENTS AND METHODS ONSDs were measured on preoperative brain CT images from 64 adult patients with hydrocephalus who underwent extracranial ventricular drainage or a ventriculoperitoneal shunt in 2016. ICP was defined as ventricular fluid pressure. RESULTS The ONSD measured on preoperative CT was greater in patients (n = 8) with a higher ICP (>20 mmHg, 5.8vs. 4.9 mm, P = 0.001). The ONSD was linearly correlated with ICP (r = 0.543, P < 0.001) and was predictive of increased ICP with an area under the receiver operating characteristic curve of 0.834. The optimal cut-off value of 5.3 mm ONSD yielded 88% sensitivity and 79% specificity. The inter-class coefficient of ONSD on preoperative CT was 0.882. The correlation between ONSD on preoperative CT and ICP was detected only in patients with communicating and non-communicating hydrocephalus (r = 0.437 and r = 0.585, P = 0.037 and P = 0.002, respectively). CONCLUSION ONSD measured on preoperative brain CT was linearly correlated with ICP in adult patients with communicating and non-communicating hydrocephalus, and it was a predictor of increased ICP with good discrimination and high inter-observer reliability. These results suggest that preoperative ONSD measurement on brain CT can be helpful to safely manage such patients by providing information about ICP.
Collapse
Affiliation(s)
- Hyung-Chul Lee
- Department of Anesthesiology and Pain Medicine, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea
| | - Won-Jong Lee
- Department of Anesthesiology and Pain Medicine, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea
| | - Yun-Sik Dho
- Department of Neurosurgery, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea
| | - Won-Sang Cho
- Department of Neurosurgery, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea
| | - Yong Hwy Kim
- Department of Neurosurgery, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea
| | - Hee-Pyoung Park
- Department of Anesthesiology and Pain Medicine, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
| |
Collapse
|
17
|
Wenz D, Kuehne A, Huelnhagen T, Nagel AM, Waiczies H, Weinberger O, Oezerdem C, Stachs O, Langner S, Seeliger E, Flemming B, Hodge R, Niendorf T. Millimeter spatial resolution in vivo sodium MRI of the human eye at 7 T using a dedicated radiofrequency transceiver array. Magn Reson Med 2018; 80:672-684. [DOI: 10.1002/mrm.27053] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2017] [Revised: 10/18/2017] [Accepted: 11/30/2017] [Indexed: 12/23/2022]
Affiliation(s)
- Daniel Wenz
- Berlin Ultrahigh Field Facility, Max Delbrueck Center for Molecular Medicine in the Helmholtz Association; Berlin Germany
| | | | - Till Huelnhagen
- Berlin Ultrahigh Field Facility, Max Delbrueck Center for Molecular Medicine in the Helmholtz Association; Berlin Germany
| | - Armin M. Nagel
- Institute of Radiology; University Hospital Erlangen; Erlangen Germany
- Division of Medical Physics in Radiology, German Cancer Research Centre (DKFZ); Heidelberg Germany
| | | | - Oliver Weinberger
- Berlin Ultrahigh Field Facility, Max Delbrueck Center for Molecular Medicine in the Helmholtz Association; Berlin Germany
| | - Celal Oezerdem
- Berlin Ultrahigh Field Facility, Max Delbrueck Center for Molecular Medicine in the Helmholtz Association; Berlin Germany
| | - Oliver Stachs
- Department of Ophthalmology; University of Rostock; Rostock Germany
| | - Soenke Langner
- Institute for Diagnostic Radiology and Neuroradiology; University Medicine Greifswald; Greifswald Germany
| | - Erdmann Seeliger
- Institute of Physiology; Charité University Medicine; Berlin Germany
| | - Bert Flemming
- Institute of Physiology; Charité University Medicine; Berlin Germany
| | - Russell Hodge
- Berlin Ultrahigh Field Facility, Max Delbrueck Center for Molecular Medicine in the Helmholtz Association; Berlin Germany
| | - Thoralf Niendorf
- Berlin Ultrahigh Field Facility, Max Delbrueck Center for Molecular Medicine in the Helmholtz Association; Berlin Germany
- MRI.TOOLS GmbH; Berlin Germany
| |
Collapse
|
18
|
Lee JY, Kwon HJ, Park SJ, Yoo C, Kim YY, Kim EY. Signal Alteration in the Optic Nerve Head on 3D T2-weighted MRI: a Potential Neuroimaging Sign of Glaucomatous Optic Neuropathy. Curr Eye Res 2017; 43:397-405. [PMID: 29120259 DOI: 10.1080/02713683.2017.1399426] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
PURPOSE To investigate whether a signal alteration (SA) in the optic nerve head (ONH) on 3D T2-weighted magnetic resonance imaging (MRI) is associated with glaucomatous optic neuropathy Materials and Methods: A total of 35 patients with bilateral open-angle glaucoma and 31 age-matched controls underwent 3D high-resolution (0.98 × 0.98 × 1 mm3) T2-weighted MRI and detailed ophthalmologic examinations including spectral-domain optical coherence tomography (OCT). Two independent reviewers blinded to subject data determined mild or prominent SA on 3D T2-weighted MRI for the incomplete or complete loss of ocular hypointense continuity in the ONH, respectively. The prevalence of SAs was compared between the two groups with the chi-square test. The OCT measurements were compared among the eyes with a mild or prominent SA and those without an SA using the Kruskal-Wallis test. RESULTS Of the 35 eyes with glaucoma, 26 eyes (74.3%) exhibited an SA in the ONH, whereas it was observed in 5 (16.1%) of the 31 controls (P < 0.001). The eyes with a prominent SA had a significantly different average retinal nerve fiber layer thickness (P = 0.002) and the ONH parameters except for the disk area (all P < 0.001) than those without an SA. The eyes with a mild SA had a significantly narrower neural rim area, larger cup volume, and larger average and vertical cup-to-disk ratios compared with those without an SA (P = 0.011, 0.003, 0.004, and 0.004, respectively) Conclusions: The SA in the ONH on 3D T2-weighted MRI was significantly more frequent in eyes with open-angle glaucoma than in the controls.
Collapse
Affiliation(s)
- Jong Yeon Lee
- a Department of Ophthalmology , Gachon University College of Medicine, Gil Medical Center , Incheon , Korea
| | - Hyo Jeong Kwon
- b Gachon University College of Medicine , Incheon , Korea
| | - Su Jin Park
- a Department of Ophthalmology , Gachon University College of Medicine, Gil Medical Center , Incheon , Korea
| | - Chungkwon Yoo
- c Department of Ophthalmology , Korea University College of Medicine , Seoul , Korea
| | - Yong Yeon Kim
- c Department of Ophthalmology , Korea University College of Medicine , Seoul , Korea
| | - Eung Yeop Kim
- d Department of Radiology , Gachon University College of Medicine, Gil Medical Center , Incheon , Korea
| |
Collapse
|
19
|
Morphologic and biometric evaluation of chick embryo eyes in ovo using 7 Tesla MRI. Sci Rep 2017; 7:2647. [PMID: 28572591 PMCID: PMC5453995 DOI: 10.1038/s41598-017-02755-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2017] [Accepted: 04/18/2017] [Indexed: 01/06/2023] Open
Abstract
The purposes of this study were (1) to characterize embryonic eye development during incubation in ovo and (2) to analyze the putative influence of repetitive ultrahigh-field MRI (UHF-MRI) measurements on this development. A population of 38 fertilized chicken eggs was divided into two sub-groups: two eggs (Group A) were examined repeatedly during the developmental period from embryonic day 1 (E1) to embryonic day 20 (E20) to evaluate the influence of daily MRI scanning. A second larger group of 36 eggs was examined pairwise on one day only, from E3 to E20, and the embryos were sacrificed immediately after MR imaging (Group B). Fast T2-weighted MR sequences provided biometric data on the eye with an in-plane resolution of 74 μm. The data show rapid growth of the eye with a steep increase in intraocular dimensions in all axis directions and in eyeball volume during initial development up to E10, followed by a phase of reduced growth rate in later developmental stages. Comparison of the two groups revealed no differences in ocular development.
Collapse
|
20
|
Abstract
PURPOSE To report the case of a melanocytoma of the optic disc leading to severe vision loss, raising concern for possible malignant transformation and optic nerve infiltration. METHODS Case report. RESULTS A 36-year-old Arabic woman presented to an outside facility with severe vision loss and a clinical picture concerning for optic neuritis with central retinal vein occlusion. On referral to the authors' institution 1 month after initial presentation, the vision of the patient was no light perception in the affected eye, and examination revealed the presence of a pigmented lesion adjacent to the nerve. Although standard 3-T magnetic resonance imaging orbits suggested 15 mm of optic nerve involvement, ultrahigh resolution 7-T magnetic resonance imaging was able to detect only 2 mm of optic nerve involvement. CONCLUSION Melanocytoma of the optic disc is most often benign and causes few visual symptoms. However, in rare cases it can lead to severe vision loss and raise concern for malignant transformation. A 7-T magnetic resonance imaging provides higher resolution optic nerve images.
Collapse
|
21
|
Oberacker E, Paul K, Huelnhagen T, Oezerdem C, Winter L, Pohlmann A, Boehmert L, Stachs O, Heufelder J, Weber A, Rehak M, Seibel I, Niendorf T. Magnetic resonance safety and compatibility of tantalum markers used in proton beam therapy for intraocular tumors: A 7.0 Tesla study. Magn Reson Med 2016; 78:1533-1546. [DOI: 10.1002/mrm.26534] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2016] [Revised: 09/29/2016] [Accepted: 10/07/2016] [Indexed: 12/13/2022]
Affiliation(s)
- Eva Oberacker
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association; Berlin Germany
| | - Katharina Paul
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association; Berlin Germany
| | - Till Huelnhagen
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association; Berlin Germany
| | - Celal Oezerdem
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association; Berlin Germany
| | - Lukas Winter
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association; Berlin Germany
| | - Andreas Pohlmann
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association; Berlin Germany
| | - Laura Boehmert
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association; Berlin Germany
| | - Oliver Stachs
- Department of Ophthalmology; University of Rostock; Rostock Germany
| | - Jens Heufelder
- Charité-Universitätsmedizin Berlin, BerlinProtonen am HZB; Berlin Germany
| | - Andreas Weber
- Charité-Universitätsmedizin Berlin, BerlinProtonen am HZB; Berlin Germany
| | - Matus Rehak
- Charité-Universitätsmedizin Berlin, Klinik für Augenheilkunde Campus Benjamin Franklin; Berlin Germany
| | - Ira Seibel
- Charité-Universitätsmedizin Berlin, Klinik für Augenheilkunde Campus Benjamin Franklin; Berlin Germany
| | - Thoralf Niendorf
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association; Berlin Germany
- Experimental and Clinical Research Center (ECRC), a joint cooperation between the Charité Medical Faculty and the Max Delbrück Center for Molecular Medicine in the Helmholtz Association; Berlin Germany
| |
Collapse
|
22
|
Niendorf T, Paul K, Oezerdem C, Graessl A, Klix S, Huelnhagen T, Hezel F, Rieger J, Waiczies H, Frahm J, Nagel AM, Oberacker E, Winter L. W(h)ither human cardiac and body magnetic resonance at ultrahigh fields? technical advances, practical considerations, applications, and clinical opportunities. NMR IN BIOMEDICINE 2016; 29:1173-97. [PMID: 25706103 DOI: 10.1002/nbm.3268] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2014] [Revised: 12/26/2014] [Accepted: 01/13/2015] [Indexed: 05/12/2023]
Abstract
The objective of this study was to document and review advances and groundbreaking progress in cardiac and body MR at ultrahigh fields (UHF, B0 ≥ 7.0 T) with the goal to attract talent, clinical adopters, collaborations and resources to the biomedical and diagnostic imaging communities. This review surveys traits, advantages and challenges of cardiac and body MR at 7.0 T. The considerations run the gamut from technical advances to clinical opportunities. Key concepts, emerging technologies, practical considerations, frontier applications and future directions of UHF body and cardiac MR are provided. Examples of UHF cardiac and body imaging strategies are demonstrated. Their added value over the kindred counterparts at lower fields is explored along with an outline of research promises. The achievements of cardiac and body UHF-MR are powerful motivators and enablers, since extra speed, signal and imaging capabilities may be invested to overcome the fundamental constraints that continue to hamper traditional cardiac and body MR applications. If practical obstacles, concomitant physics effects and technical impediments can be overcome in equal measure, sophisticated cardiac and body UHF-MR will help to open the door to new MRI and MRS approaches for basic research and clinical science, with the lessons learned at 7.0 T being transferred into broad clinical use including diagnostics and therapy guiding at lower fields. Copyright © 2015 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Thoralf Niendorf
- Berlin Ultrahigh Field Facility (BUFF), Max-Delbrueck Center for Molecular Medicine, Berlin, Germany
- DZHK (German Centre for Cardiovascular Research), Partner Site, Berlin, Germany
| | - Katharina Paul
- Berlin Ultrahigh Field Facility (BUFF), Max-Delbrueck Center for Molecular Medicine, Berlin, Germany
| | - Celal Oezerdem
- Berlin Ultrahigh Field Facility (BUFF), Max-Delbrueck Center for Molecular Medicine, Berlin, Germany
| | - Andreas Graessl
- Berlin Ultrahigh Field Facility (BUFF), Max-Delbrueck Center for Molecular Medicine, Berlin, Germany
| | - Sabrina Klix
- Berlin Ultrahigh Field Facility (BUFF), Max-Delbrueck Center for Molecular Medicine, Berlin, Germany
| | - Till Huelnhagen
- Berlin Ultrahigh Field Facility (BUFF), Max-Delbrueck Center for Molecular Medicine, Berlin, Germany
| | - Fabian Hezel
- Berlin Ultrahigh Field Facility (BUFF), Max-Delbrueck Center for Molecular Medicine, Berlin, Germany
| | | | | | - Jens Frahm
- Biomedizinische NMR Forschungs GmbH, am Max-Planck-Institut für biophysikalische Chemie, Göttingen, Germany
- DZHK (German Centre for Cardiovascular Research), Partner Site, Göttingen, Germany
| | - Armin M Nagel
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Eva Oberacker
- Berlin Ultrahigh Field Facility (BUFF), Max-Delbrueck Center for Molecular Medicine, Berlin, Germany
| | - Lukas Winter
- Berlin Ultrahigh Field Facility (BUFF), Max-Delbrueck Center for Molecular Medicine, Berlin, Germany
| |
Collapse
|
23
|
Wezel J, Garpebring A, Webb AG, van Osch MJ, Beenakker JWM. Automated eye blink detection and correction method for clinical MR eye imaging. Magn Reson Med 2016; 78:165-171. [DOI: 10.1002/mrm.26355] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2016] [Revised: 06/14/2016] [Accepted: 07/05/2016] [Indexed: 12/13/2022]
Affiliation(s)
- Joep Wezel
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center; Leiden The Netherlands
| | - Anders Garpebring
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center; Leiden The Netherlands
- Radiation Sciences; Umeå University; Umeå Sweden
| | - Andrew G. Webb
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center; Leiden The Netherlands
| | - Matthias J.P. van Osch
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center; Leiden The Netherlands
| | - Jan-Willem M. Beenakker
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center; Leiden The Netherlands
- Department of Ophthalmology; Leiden University Medical Center; Leiden The Netherlands
| |
Collapse
|
24
|
Singh AD, Platt SM, Lystad L, Lowe M, Oh S, Jones SE, Alzahrani Y, Plesec T. Optic Nerve Assessment Using 7-Tesla Magnetic Resonance Imaging. Ocul Oncol Pathol 2016; 2:178-80. [PMID: 27239461 DOI: 10.1159/000443650] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2015] [Revised: 12/08/2015] [Indexed: 11/19/2022] Open
Abstract
PURPOSE The purpose of this study was to correlate high-resolution magnetic resonance imaging (MRI) and histologic findings in a case of juxtapapillary choroidal melanoma with clinical evidence of optic nerve invasion. METHODS With institutional review board approval, an enucleated globe with choroidal melanoma and optic nerve invasion was imaged using a 7-tesla MRI followed by histopathologic evaluation. RESULTS Optical coherence tomography, B-scan ultrasonography, and 1.5-tesla MRI of the orbit (1-mm sections) could not detect optic disc invasion. Ex vivo, 7-tesla MRI detected optic nerve invasion, which correlated with histopathologic features. CONCLUSIONS Our case demonstrates the potential to document the existence of optic nerve invasion in the presence of an intraocular tumor, a feature that has a major bearing on decision making, particularly for consideration of enucleation.
Collapse
Affiliation(s)
- Arun D Singh
- Department of Ophthalmic Oncology, Cole Eye Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Sean M Platt
- Department of Ophthalmic Oncology, Cole Eye Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Lisa Lystad
- Department of Ophthalmic Oncology, Cole Eye Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Mark Lowe
- Imaging Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Sehong Oh
- Imaging Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | | | - Yahya Alzahrani
- Department of Ophthalmic Oncology, Cole Eye Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Thomas Plesec
- Pathology Institute, Cleveland Clinic, Cleveland, Ohio, USA
| |
Collapse
|
25
|
Vaiman M, Abuita R, Bekerman I. Optic nerve sheath diameters in healthy adults measured by computer tomography. Int J Ophthalmol 2015; 8:1240-4. [PMID: 26682181 DOI: 10.3980/j.issn.2222-3959.2015.06.30] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2014] [Accepted: 11/18/2014] [Indexed: 11/02/2022] Open
Abstract
AIM To measure optic nerve sheath diameters (ONSD) in different locations by computer tomography (CT) and to recommend the best location for cases when ONSD is used for intracranial pressure monitoring. METHODS In a prospective cohort study, CT data of 300 healthy adults were analyzed (600 eyes). In all cases, the CT investigation was performed at the Emergency Department because of the various conditions that proved not to be connected with ophthalmological or neurological pathology. The ONSD were measured at 3 mm and 8 mm distance from the globe, and 3 mm from the anterior opening of the optic canal. The correlation analysis was performed with gender, age, and ethnic background. RESULTS The right/left ONSD are 4.94±1.51/5.17±1.34 mm at 3 mm, 4.35±0.76/4.45±0.62 mm at 8 mm from the globe, and 3.55±0.82/3.65±0.7 mm at 3 mm from the optic canal. No significant differences correlated with gender of the patients, their age, and ethnic background were found. CONCLUSION In healthy persons, the ONSD varies from 5.17±1.34 mm to 3.55±0.82 mm in different locations within the intraorbital space. The most stable results with lesser standard deviation can be obtained if it is measured 8-10 mm from the globe.
Collapse
Affiliation(s)
- Michael Vaiman
- Department of Otolaryngology-Head and Neck Surgery, Assaf Harofe Medical Center, Affiliated to Sackler Faculty of Medicine, Tel Aviv University, Zerifin 70300, Israel
| | - Rani Abuita
- Department of Otolaryngology-Head and Neck Surgery, Assaf Harofe Medical Center, Affiliated to Sackler Faculty of Medicine, Tel Aviv University, Zerifin 70300, Israel
| | - Inessa Bekerman
- Department of Radiology, Assaf Harofe Medical Center, Affiliated to Sackler Faculty of Medicine, Tel Aviv University, Zerifin 70300, Israel
| |
Collapse
|
26
|
Natori Y, Yoshizawa H, Mizuno H, Hayashi A. Preoperative transcutaneous electrical nerve stimulation for localizing superficial nerve paths. J Plast Reconstr Aesthet Surg 2015; 68:1713-8. [PMID: 26420473 DOI: 10.1016/j.bjps.2015.08.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2014] [Revised: 05/26/2015] [Accepted: 08/12/2015] [Indexed: 10/23/2022]
Abstract
During surgery, peripheral nerves are often seen to follow unpredictable paths because of previous surgeries and/or compression caused by a tumor. Iatrogenic nerve injury is a serious complication that must be avoided, and preoperative evaluation of nerve paths is important for preventing it. In this study, transcutaneous electrical nerve stimulation (TENS) was used for an in-depth analysis of peripheral nerve paths. This study included 27 patients who underwent the TENS procedure to evaluate the peripheral nerve path (17 males and 10 females; mean age: 59.9 years, range: 18-83 years) of each patient preoperatively. An electrode pen coupled to an electrical nerve stimulator was used for superficial nerve mapping. The TENS procedure was performed on patients' major peripheral nerves that passed close to the surgical field of tumor resection or trauma surgery, and intraoperative damage to those nerves was apprehensive. The paths of the target nerve were detected in most patients preoperatively. The nerve paths of 26 patients were precisely under the markings drawn preoperatively. The nerve path of one patient substantially differed from the preoperative markings with numbness at the surgical region. During surgery, the nerve paths could be accurately mapped preoperatively using the TENS procedure as confirmed by direct visualization of the nerve. This stimulation device is easy to use and offers highly accurate mapping of nerves for surgical planning without major complications. The authors conclude that TENS is a useful tool for noninvasive nerve localization and makes tumor resection a safe and smooth procedure.
Collapse
Affiliation(s)
- Yuhei Natori
- Department of Plastic and Reconstructive Surgery, Juntendo University School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo 113-8421, Japan
| | - Hidekazu Yoshizawa
- Department of Plastic and Reconstructive Surgery, Juntendo University School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo 113-8421, Japan
| | - Hiroshi Mizuno
- Department of Plastic and Reconstructive Surgery, Juntendo University School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo 113-8421, Japan
| | - Ayato Hayashi
- Department of Plastic and Reconstructive Surgery, Juntendo University School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo 113-8421, Japan.
| |
Collapse
|
27
|
Berkowitz BA, Bissig D, Roberts R. MRI of rod cell compartment-specific function in disease and treatment in vivo. Prog Retin Eye Res 2015; 51:90-106. [PMID: 26344734 DOI: 10.1016/j.preteyeres.2015.09.001] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2015] [Revised: 08/26/2015] [Accepted: 09/01/2015] [Indexed: 10/23/2022]
Abstract
Rod cell oxidative stress is a major pathogenic factor in retinal disease, such as diabetic retinopathy (DR) and retinitis pigmentosa (RP). Personalized, non-destructive, and targeted treatment for these diseases remains elusive since current imaging methods cannot analytically measure treatment efficacy against rod cell compartment-specific oxidative stress in vivo. Over the last decade, novel MRI-based approaches that address this technology gap have been developed. This review summarizes progress in the development of MRI since 2006 that enables earlier evaluation of the impact of disease on rod cell compartment-specific function and the efficacy of anti-oxidant treatment than is currently possible with other methods. Most of the new assays of rod cell compartment-specific function are based on endogenous contrast mechanisms, and this is expected to facilitate their translation into patients with DR and RP, and other oxidative stress-based retinal diseases.
Collapse
Affiliation(s)
- Bruce A Berkowitz
- Dept. of Anatomy and Cell Biology, Wayne State University School of Medicine, Detroit, MI, USA; Dept. Of Ophthalmology, Wayne State University School of Medicine, Detroit, MI, USA.
| | - David Bissig
- Dept. of Anatomy and Cell Biology, Wayne State University School of Medicine, Detroit, MI, USA
| | - Robin Roberts
- Dept. Of Ophthalmology, Wayne State University School of Medicine, Detroit, MI, USA
| |
Collapse
|
28
|
Anatomic and pathological characterization of choroidal melanoma using multimodal imaging. Melanoma Res 2015; 25:252-8. [DOI: 10.1097/cmr.0000000000000156] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
|
29
|
Diffusion-Sensitized Ophthalmic Magnetic Resonance Imaging Free of Geometric Distortion at 3.0 and 7.0 T. Invest Radiol 2015; 50:309-21. [DOI: 10.1097/rli.0000000000000129] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
30
|
Ruytenberg T, Webb AG, Beenakker JWM. A multi-purpose open-source triggering platform for magnetic resonance. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2014; 247:15-21. [PMID: 25222861 DOI: 10.1016/j.jmr.2014.08.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2014] [Revised: 08/19/2014] [Accepted: 08/21/2014] [Indexed: 06/03/2023]
Abstract
Many MR scans need to be synchronised with external events such as the cardiac or respiratory cycles. For common physiological functions commercial trigger equipment exists, but for more experimental inputs these are not available. This paper describes the design of a multi-purpose open-source trigger platform for MR systems. The heart of the system is an open-source Arduino Due microcontroller. This microcontroller samples an analogue input and digitally processes these data to determine the trigger. The output of the microcontroller is programmed to mimic a physiological signal which is fed into the electrocardiogram (ECG) or pulse oximeter port of MR scanner. The microcontroller is connected to a Bluetooth dongle that allows wireless monitoring and control outside the scanner room. This device can be programmed to generate a trigger based on various types of input. As one example, this paper describes how it can be used as an acoustic cardiac triggering unit. For this, a plastic stethoscope is connected to a microphone which is used as an input for the system. This test setup was used to acquire retrospectively-triggered cardiac scans in ten volunteers. Analysis showed that this platform produces a reliable trigger (>99% triggers are correct) with a small average 8 ms variation between the exact trigger points.
Collapse
Affiliation(s)
- T Ruytenberg
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - A G Webb
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - J W M Beenakker
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands.
| |
Collapse
|